0% found this document useful (0 votes)
1K views1 page

D.P. Test Report

The inspection report summarizes non-destructive testing of equipment. Key details include: 1) Material specifications, thickness and type were inspected, along with weld details. 2) The surface was examined at 100% coverage with 1000-1200 lux light intensity. 3) Dye penetrant testing was performed by brushing, spraying or dipping the penetrant at ambient temperature for 10 minutes of dwell time followed by 10 minutes of developing time.

Uploaded by

virendra katke
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views1 page

D.P. Test Report

The inspection report summarizes non-destructive testing of equipment. Key details include: 1) Material specifications, thickness and type were inspected, along with weld details. 2) The surface was examined at 100% coverage with 1000-1200 lux light intensity. 3) Dye penetrant testing was performed by brushing, spraying or dipping the penetrant at ambient temperature for 10 minutes of dwell time followed by 10 minutes of developing time.

Uploaded by

virendra katke
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Report No: QC/DP-01

INSPECTION REPORT Date


Page 01 OF 01
QULITY ASSURANCE & CONTROL
PROJECT CUSTOMER

PMC MAIN SUPPLIER


SUB SUPPLIER MANUFACTURER
PO NO. QAP NO

EQUIPMENT CLIENT DRG. NO.

BGR DRG. NO. TAG NO./ QTY.

D. P. TEST REPORT
Code Spec: ASME Sec VII Div1 & ASME Sec V Procedure No:
Examination Stage: Date of Examination:

Sr. No. Description of Job


1 Material Specification
2 Material Thk. & Type
3 Weld Details
4 Extent of Examination 100%
5 Light Intensity 1000 - 1200 lux
6 Surface Condition:-
Ground Machined As Welded
7 Application of Pentrant:-
Brushing Spraying Dipping
8 Surface Temprature Ambient (Deg C)
9 Dwell Time 10 Min.
10 Developing Time 10 Min.
11 Consumable Details: Batch No. Expiry Date
Cleaner
Dye Pentrant
Developer
12 Type of DP Material
Visible (Non-Fluoroscent) Water Washable
Fluoroscent Solevant Removable
Remarks:-

FOR SS FILTERS PVT. LTD. FOR CLINET/TPI