0% found this document useful (0 votes)
454 views12 pages

Objectives of Shunt Compensation

FACTS Devices
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
454 views12 pages

Objectives of Shunt Compensation

FACTS Devices
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 12
OBJECTIVES OF SHUNT COMPENSATION © Steady-state transmittable power can be increased. © Voltage profile can be controlled. © Shunt connected reactors (fixed or mechanically switched) are applied to minimize line over voltage under light load conditions. o Shunt connected capacitors are applied to maintain voltage levels under heavy load conditions. MIDPOINT REGULATION FOR LINE SEGMENTATION o Consider two bus transmission model with ideal var compensator at the midpoint. X12 dem Ime X/2 — > © The compensator divides line into 2 parts. MIDPOINT REGULATION FOR LINE SEGMENTATION © Midpoint var compensator exchange only reactive power with the line. o Real power is same at each terminal 6 4V 8 Vin = Vie = Veos 33 Ton = Ine = = Se 8i MIDPOINT REGULATION FOR LINE SEGMENTATION o The transmitted power is P= Vonbin = Vardar = Verto cos$ = Vr eos $ o The relation between P,Q and angle 6 ave. 2 Panay to---5 7 Pp= x in 6/2 2 = sind MIDPOINT REGULATION FOR LINE SEGMENTATION © Midpoint shunt compensation significantly increase the transmittable power. © Mid point of the transmission line is the best location for the compensator. o Voltage sag is maximum at the mid point. END OF LINE VOLTAGE SUPPORT TO PREVENT VOLTAGE INSTABILITY © Consider a radial Transmission line END OF LINE VOLTAGE SUPPORT TO PREVENT VOLTAGE INSTABILITY END OF LINE VOLTAGE SUPPORT TO PREVENT VOLTAGE INSTABILITY o Reactive shunt compensation can effectively increase the voltage stability limit and regulates the terminal voltage. o End of the line is the best location for compensator. IMPROVEMENT OF TRANSIENT STABILITY a (pre-fault) ¢ (post-fault) O 84 6p wI2 bg bqy 0 TB IMPROVEMENT OF TRANSIENT STABILITY IMPROVEMENT OF TRANSIENT STABILITY P 2P ax ov? Po= “X, sin 6/2 Abmargin P. 5 550 553 6 ot %p2 %3 Derit = 7 6 POWER OSCILLATION DAMPING Ph (b) p af Undamped (a) 5 Damped \__~__"_"___, t Undamped Damped Pig

You might also like