0% found this document useful (0 votes)
2K views2 pages

4BHK - Electrical Layout

The document contains a legend describing various lighting fixtures and electrical points. It includes symbols and descriptions for ceiling lights, wall lights, chandeliers, switches, and more. The legend is intended to provide information on the types of fixtures and equipment shown on an electrical plan.

Uploaded by

Dausori Satish
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views2 pages

4BHK - Electrical Layout

The document contains a legend describing various lighting fixtures and electrical points. It includes symbols and descriptions for ceiling lights, wall lights, chandeliers, switches, and more. The legend is intended to provide information on the types of fixtures and equipment shown on an electrical plan.

Uploaded by

Dausori Satish
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

LEGENDS

SYMBOL DESCRIPTION

2X18W CEILING LIGHT FIXTURE

MIRROR LIGHT FIXTURE @ 100mm AM.

WALL MOUNTED LIGHT FIXTURE @ 2200mm AFF.

1 2 3 4 5 6 7 8 9 CIELING LIGHT FIXTURE

3'-0" 7'-3" 3'-3" 2'-9" 7'-6" 6'-512" 6'-012" 8'-212"


CHANDLIER LIGHT POINT
4'-312"
COMPOUND LIGHT

EX EX EX
BULK HEAD LIGHT FIXTURE
A
ex ex B
ML L8g Lf L8a-f
G2 CEILING FAN POINT (FAN HOOK)
L8g
G1
EX
EXHAUST FAN POINT
L9d
L6a L6b L7
L6 L8e L8d SINGLE POLE SWITCH @ 1200mm FROM FFL.
L6ex L6a-b
G1 B SINGLE POLE SWITCH FOR LIGHTING & FAN @ 600mm AFF AT BEDSIDE.
CKT G1
11'-7"

ML
TO LPDB2 B ex L7 L8F1
B
AC3
TWO WAY SINGLE POLE SWITCH FOR LIGHTING @ 600mm AFF @ BEDSIDE.
CKT L7 L9c
TO LPDB2 ML TWO WAY SWITCH @ 1200mm FROM FFL.
L5d L5e
AC3 AC4
L8f L8c G 16A SWITCH @ 1200mm FROM FFL.

L5F1 G2L9c,d ex FAN REGULATOR WITH SWITCH @ 1200mm FROM FFL.


AC4
L9a,b L9a
B CKT L8
B FAN REGULATOR WITH SWITCH @ 600mm AFF BED SIDE

L3c BELL PUSH @ 1200mm FROM FFL.


TO LPDB2
5'-3"

L8a L9b CALL BELL @ 2250mm FROM FFL.


L5c L5f L8b

CKT L8 TELEPHONE SOCKET OUTLET @ 150mm AFF.


CKT L5
L8a-f TO LPDB2
TO LPDB2 L3a,b,c
L8F1
TV POINT @ 1200mm AFF.
C L5F1
L5a-f
L1f
1X36W SURFACE MOUNTED LIGHT FIXTURE
L1f EDB
6A SOCKET FOR EXHAUST FAN POINT @ 2300 ABOVE FALSE CEILING
4'-8"

L3a L3b EX
FOR TOILETS & @ 2200 FOR KITCHEN
6A 5PIN SWITCHED SOCKET OUTLET @ 1200 AFF
L5b L5a
ALONG WITH OTHER CONTROL SWITCH. (DEPENDENT)
L1e L1d
D FR
6A 5PIN SWITCHED SOCKET OUTLET @ 150 AFF. (INDEPENDENT)
L4a-f
B
CKT L4 CKT L2 6A 5PIN SWITCHED SOCKET OUTLET @ 600 AFF BED SIDE.
AG TO LPDB2 TO LPDB2 L1F2
CR
L4f L4a TWIN 6A 5PIN SWITCHED SOCKET OUTLET 150mm AFF.
ex
L2d L2a
M 6A 5PIN SWITCHED SOCKET OUTLET @ 300mm ABC FOR MIXER
EX
L2F1
L2a-d L1F2 CH 6A SOCKET OUTLET @ 2100mm AFF FOR ELECTRIC CHIMNEY.
L1F1 To TEL
L2F1 L1a-e CKT L1 FR
AC1 6A SWITCHED UNIVERSAL SOCKET OUTLET @ 600mm AFF FOR FRIDGE.
AC2 TO LPDB2
15'-6"

L1c
To TV WM 16/6A 5PIN SWITCHED SOCKET OUTLET @ 900mm AFF
L4e L4b
FOR WASHING MACHINE.
L2c L2b
Data G 16A 3PIN SOCKET OUTLET @ 2250mm AFF, OR ABOVE
HOB AC1
FALSE CEILING FOR GEYSER.
CR
AC 16A 3PIN SOCKET OUTLET @ 2400mm AFF FOR AC
DW CKT P1
TO LPDB2 IG 16/6A SWITCHED UNIVERSAL SOCKET OUTLET @ 1000mm ABC
L1F1 FOR INSTANT GEYSER
AC2 CR 16/6A SWITCHED UNIVERSAL SOCKET OUTLET @ 300mm ABC
L4d L4c FOR COOKING RANGE.
AG
6A 5PIN SWITCHED SOCKET OUTLET @ 1000mm ABC FOR AQUAGUARD.
L1a L1b
E L1a-e WALL MOUNTED SPEAKER POINT AT 2400MM AFF
L1F2
L1F1
VARIFOCAL LENS 4MM-9MM WITH A COVERAGE
ANGLE UPTO 30 DEG. (INDOOR)
Forest Creek-Type 2- GF Electrical
D DATA POINT @ 1200mm AFF. Layout
DISTRIBUTION BOARD TOP AT 2250mm AFF OR AT LINTEL TOP NOTE:
1. All dimensions and levels are in Inches. unless otherwise
AM ABOVE MIRROR
13'-0"

mentioned.
AFF/ABC/FFL ABOVE FINISHED FLOOR /ABOVE COUNTER/FINISHED FLOOR LVL.
Mapping, Planning and GIS Solution
( Architectural Services )
Scale: Sign:

F
4'-012"

Project Forest Creek , Narsapura- HYD


Building Code : Type 2 Villa
G

Reference
DWG No : AG-269-EL001-R0
Type 2 Ground floor-Electrical Layout DWG Date
Prepared by
: 25.06.2023
: Monish(Project Architect)
Checked by : Surendra(Project Architect)
: 8870945883

Aerial Geomatics
Mapping, Planning and GIS Solutions
#10, 2nd Cross, Om Sai Ram Layout,
Myadarahalli, Bangalore-560015.
Contact: 9686906493, Email: admin@aerialgeomatics.com
Website: www.aerialgeomatics.com
LEGENDS

SYMBOL DESCRIPTION

2X18W CEILING LIGHT FIXTURE

1 2 3 4 5 6 7 8 9 MIRROR LIGHT FIXTURE @ 100mm AM.

3'-0" 7'-3" 3'-3" 2'-9" 7'-6" 6'-512" 6'-012" 8'-212" WALL MOUNTED LIGHT FIXTURE @ 2200mm AFF.

CIELING LIGHT FIXTURE

EX EX
CHANDLIER LIGHT POINT
A ex ex
G3 G4 COMPOUND LIGHT
ML
L12g
L12g BULK HEAD LIGHT FIXTURE
L11d
L11a
L10a L10b L10c L12e L12f
CEILING FAN POINT (FAN HOOK)

L10a,b L12e,f EX

11'-7"
ex ex EXHAUST FAN POINT
G1 G2
L10a-d Lf L12a-d L12F1 SINGLE POLE SWITCH @ 1200mm FROM FFL.
Lf

B SINGLE POLE SWITCH FOR LIGHTING & FAN @ 600mm AFF AT BEDSIDE.
AC5 AC6 L12d L12c

L10c L10d L11b L12i B TWO WAY SINGLE POLE SWITCH FOR LIGHTING @ 600mm AFF @ BEDSIDE.
CKT L12
L10F1 L12F1 TWO WAY SWITCH @ 1200mm FROM FFL.
TO LPDB2
AC5 G
B AC6 16A SWITCH @ 1200mm FROM FFL.
L10a-d CKT L10 L11a-c L12a-d
L10F1 L12F1 FAN REGULATOR WITH SWITCH @ 1200mm FROM FFL.
TO LPDB2
CKT L11
5'-3"

L10b L10a B FAN REGULATOR WITH SWITCH @ 600mm AFF BED SIDE
TO LPDB2 L12h
L11c
L12a L12b BELL PUSH @ 1200mm FROM FFL.
L12h,i
CALL BELL @ 2250mm FROM FFL.
C L13a-d
TELEPHONE SOCKET OUTLET @ 150mm AFF.
4'-8"

L13d L13c L13b TV POINT @ 1200mm AFF.


CKT L12 L13a
TO LPDB2 1X36W SURFACE MOUNTED LIGHT FIXTURE
6A SOCKET FOR EXHAUST FAN POINT @ 2300 ABOVE FALSE CEILING
EX
D FOR TOILETS & @ 2200 FOR KITCHEN
6A 5PIN SWITCHED SOCKET OUTLET @ 1200 AFF
ALONG WITH OTHER CONTROL SWITCH. (DEPENDENT)

6A 5PIN SWITCHED SOCKET OUTLET @ 150 AFF. (INDEPENDENT)


B 6A 5PIN SWITCHED SOCKET OUTLET @ 600 AFF BED SIDE.

TWIN 6A 5PIN SWITCHED SOCKET OUTLET 150mm AFF.

M 6A 5PIN SWITCHED SOCKET OUTLET @ 300mm ABC FOR MIXER


15'-6"

CH 6A SOCKET OUTLET @ 2100mm AFF FOR ELECTRIC CHIMNEY.

FR 6A SWITCHED UNIVERSAL SOCKET OUTLET @ 600mm AFF FOR FRIDGE.

WM 16/6A 5PIN SWITCHED SOCKET OUTLET @ 900mm AFF


FOR WASHING MACHINE.
G 16A 3PIN SOCKET OUTLET @ 2250mm AFF, OR ABOVE
FALSE CEILING FOR GEYSER.
AC 16A 3PIN SOCKET OUTLET @ 2400mm AFF FOR AC

IG 16/6A SWITCHED UNIVERSAL SOCKET OUTLET @ 1000mm ABC


FOR INSTANT GEYSER
E CR 16/6A SWITCHED UNIVERSAL SOCKET OUTLET @ 300mm ABC
FOR COOKING RANGE.
AG
6A 5PIN SWITCHED SOCKET OUTLET @ 1000mm ABC FOR AQUAGUARD.

WALL MOUNTED SPEAKER POINT AT 2400MM AFF


VARIFOCAL LENS 4MM-9MM WITH A COVERAGE
ANGLE UPTO 30 DEG. (INDOOR)
Forest Creek-Type 2- FF Electrical
D DATA POINT @ 1200mm AFF. Layout
DISTRIBUTION BOARD TOP AT 2250mm AFF OR AT LINTEL TOP NOTE:
1. All dimensions and levels are in Inches. unless otherwise
AM ABOVE MIRROR
mentioned.
AFF/ABC/FFL ABOVE FINISHED FLOOR /ABOVE COUNTER/FINISHED FLOOR LVL.
Mapping, Planning and GIS Solution
( Architectural Services )
Scale: Sign:

Project Forest Creek , Narsapura- HYD


Building Code : Type 2 Villa

Type 2 First floor-Electrical Layout


Reference
DWG No : AG-269-EL002-R0
DWG Date : 25.06.2023
Prepared by : Monish(Project Architect)
Checked by : Surendra(Project Architect)
: 8870945883

Aerial Geomatics
Mapping, Planning and GIS Solutions
#10, 2nd Cross, Om Sai Ram Layout,
Myadarahalli, Bangalore-560015.
Contact: 9686906493, Email: admin@aerialgeomatics.com
Website: www.aerialgeomatics.com

You might also like