3.
10 Metal Gate on Fence Wall or at the Entrance of a Building
MW Items 1.16 2.16 3.13
Simple Erection, alteration or repair… Erection, alteration,
Comparison of repair or removal…
Descriptions
at a fence wall or at an entrance to a building …
No additional load to cantilevered slab;
Not involve alteration of other structural elements;
Height of gate ≤ 3.2 m; &
Weight of at least one Weight of at least one
leaf > 300 kg. leaf > 200 kg; &
Weight of each leaf ≤ Weight of each leaf ≤
300kg; 200 kg.
Not DEW item 8 (see
6.1).
Other • B(P)R 15 – Not to open the gate over streets.
considerations • MOE Code para. 8.2, Table 2 & para. 16.4 – Provision of locking
devices that can be readily open from inside without the use of key &
control of the min. width of metal gate if the metal gate is fixed at the
entrance of building as well as the exit of any required staircase.
• PNAP APP-146 & PNRC 68 – Design & installation standards of metal
gate.
• The MOE, MOA & EVA not affected.
• Shutter Code issued by the Electrical & Mechanical Services Department
should be complied with if the metal gates are electrically operated.
• A Safety Guide on Gate Work issued by the Labour Department – Safety
tips & key points to note on gate-related work.
B(P)R represents Building (Planning) Regulations; EVA represents emergency vehicular access; MOA represents means
of access for access for firefighting & rescue; MOE represents means of escape in case of fire; MOE Code represents
Code of Practice for the Provision of Means of Escape in Case of Fire 1996; PNAP represents Practice Notes for
Authorized Person, Registered Structural Engineers & Registered Geotechnical Engineers; PNRC represents Practice Notes
for Registered Contractors & Shutter Code represents Code of Practice for Installation of Electrically Operated Sliding
Gates, Sliding Glass Doors & Rolling Shutters.
2010/10
26