i01889849
Control Valve
SMCS - 5051; 5117
Illustration 1 g00983864
Typical example
(1) Plug
(2) Spring housing
(3) Shim
(4) Shim
Table 1
Specifications for the Control Valve
Torque
Sales Plug Plug Spring
for Shim Thickness Shim Thickness
Model (1) Torque Housing
Housing (3) of Shim (4) of Shim
(2)
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.j... 10/03/2011
H45/H45 S, H50/H50 S, 63/H63/H63 S, 70/70 S/H70/H70 S, H9... Page 2 of 3
3Q- 3Q- 3Q-
H45, 150 N·m 3Q-7345 150 N·m 0.5 mm
7348 7344 1 mm (0.04 7343
H45s (110 lb (110 lb ft) (0.02 inch)
inch)
ft)
3Q- 3Q- 3Q-
H50, 220 N·m 3Q-7315 340 N·m 0.5 mm
7715 7316 1 mm (0.04 7317
H50s (162 lb (251 lb ft) (0.02 inch)
inch)
ft)
3Q- 3Q- 3Q-
63, H63, 150 N·m 3Q-7345 150 N·m 0.5 mm
7348 7344 1 mm (0.04 7343
H63s (110 lb (110 lb ft) (0.02 inch)
inch)
ft)
70, 70s, 3Q- 3Q- 3Q-
150 N·m 3Q-7315 340 N·m 0.5 mm
H70, 7348 7316 1 mm (0.04 7317
(110 lb (251 lb ft) (0.02 inch)
H70s inch)
ft)
H90C, 3Q- 3Q- 3Q-
150 N·m 3Q-7315 340 N·m 0.5 mm
H90Cs 7348 7316 1 mm (0.04 7317
(110 lb (251 lb ft) (0.02 inch)
inch)
ft)
100,
100s, 3Q- 3Q- 3Q-
220 N·m 3Q-7315 340 N·m 0.5 mm
H100, 7715 7316 1 mm (0.04 7317
(162 lb (251 lb ft) (0.02 inch)
H100s inch)
ft)
Note: For H45, H45s, H50, H50s, 70, 70s, H70, and H70s hammers, adding 1 mm (0.04 inch)
shims increases low pressure by 300 kPa (44 psi). This also increases the operating pressure by
800 kPa (116 psi).
Note: For 63, H63, and H63s hammers, adding 1 mm (0.04 inch) shims increases low pressure by
300 kPa (44 psi). This also increases the operating pressure by 1000 kPa (145 psi).
Note: For 100, 100s, H100, and H100s hammers, adding 1 mm (0.04 inch) shims increases low
pressure by 300 kPa (44 psi). This also increases the operating pressure by 1300 kPa (189 psi).
Illustration 2 g00683619
(A) Shim Thickness
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.j... 10/03/2011
H45/H45 S, H50/H50 S, 63/H63/H63 S, 70/70 S/H70/H70 S, H9... Page 3 of 3
Table 2
Recommended Shim Thickness for Control Valve
Sales Model Shim Thickness (A)
H45, H45s
3.5 mm (0.14 inch)
H50, H50s
3.5 mm (0.14 inch)
63, H63, H63s
2.0 mm (0.08 inch)
(1)
70, 70s, H70, H70s (2)
1.5 mm (0.059 inch)
(3)
70, 70s, H70, H70s
4.0 mm (0.16 inch)
1.5 mm (0.06 inch)
H90C, H90Cs to
2.0 mm (0.08 inch)
100, 100s, H100, H100s
2.0 mm (0.08 inch)
(1)
Use the shim thickness for the following range: 4KL1-752 and , 4KL1000-1032
(2)
If a new spool is installed, you must use the shim thickness for 4KL1033Up.
(3)
Use the shim thickness for the following range: 4KL753-999 and , 4KL1033-Up
Note: The shim thickness is the recommended specification for setting the control valve. This must
be checked by measuring the pressure in the low pressure circuit as you operate the hammer.
Refer to the Testing and Adjusting section of the Service Manual, "Control Valve (Operating
Pressure) - Test and Adjust".
Copyright 1993 - 2011 Caterpillar Inc. Thu Mar 10 15:09:38 EST 2011