0% found this document useful (0 votes)
331 views4 pages

EEPL CAT GPM96 Rev14

The GPM96 is a power quality and energy meter that measures important electrical system values like voltage, frequency, power, harmonics, and power factor. It has an accuracy of class 0.5S according to IEC62053 and is intended for use in electrical distribution networks, power stations, data centers, and other industrial applications. The GPM96 has built-in Modbus RTU communication and can measure up to 63rd order harmonics.

Uploaded by

csathish tgi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
331 views4 pages

EEPL CAT GPM96 Rev14

The GPM96 is a power quality and energy meter that measures important electrical system values like voltage, frequency, power, harmonics, and power factor. It has an accuracy of class 0.5S according to IEC62053 and is intended for use in electrical distribution networks, power stations, data centers, and other industrial applications. The GPM96 has built-in Modbus RTU communication and can measure up to 63rd order harmonics.

Uploaded by

csathish tgi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Graphene Power Meter – GPM96

Power Quality & Energy Meter

 Complies with IEC62053 class 0.5S


 Measurement sampling rate of 128 samples/cycle
 Build in Modbus RTU communication (optional TCP/IP)
 Measures harmonics up to 63rd order

www.eetarp.com
Graphene Power Meter – GPM96
Power Quality & Energy Meter

Product Description
The GPM96 is part of the new smart
Graphene-Meter-Series. The unit measures
all-important system values like voltage,
frequency, power, power factor, THDV, THDI
harmonics (up to 63rd), displacement power
factor, voltage crest factor, current K-factor,
or voltage unbalance. The build-in Modbus
RTU (Optional TCP/IP) interface ensures
smooth communication to any other system.

Together with an accuracy class of Cl 0.5S


(IEC62053-22) makes the GPM96 an
allrounder and an ideal choice for any analysis
in all kinds of electrical systems.

Device Features Typical Applications


 Accuracy according to IEC62053-22 Cl 0.5S  Low voltage distribution networks
 Instantaneous values, L-N voltage, L-L voltage,  Power station
frequency, power, power factor, THDV, THDI  Generation plant
harmonics, Displacement Power Factor  Data Center
(option), voltage crest factor (option), Current  Consumer billing
K factory (option), voltage unbalance (option)  Retails shop
 Harmonics up to 15th order (Optional up to  Commercial/residential building
63rd order)  Oil & Gas Plant
 Memory Recording for energy, demand, max  Offshore and marine
demand & max/min record  High tension distribution network
 Real time clock
 Build in Modbus RTU communication
 6.4kHz sampling (128 Samples/cycle) Certifications
 multi tariffs
 Optional - 4DI, 2DO
 Optional - Modbus TCP/IP
 Optional - MID certified

Electrical Safety  Power Quality  Energy Management


Technical Specification
Power Supply Working Environment
Rated Voltage AC 85 ~ 275Vac /DC 120~380Vdc Working temperature -25°C to 55°C
Power Consumption ≤7VA Storage temperature -40°C to 70°C
Withstand voltage ≥2kV Relative humidity ≤95% RH, no condensation
Working altitude ≤2000m
Communication / Interface Protection degree Front case IP54, rear case IP20
RS-485: Modbus-RTU Pollution Degree II
Physical interface RS-485
Communication speed Up to 38.4 kbps Measurement Parameters
Communication protocol Modbus-RTU Power Quality Analysis
Isolation voltage 2000 VAC (1 min) Sampling 128 points/cycle wave
Relay output Harmonic 2~63rd Harmonic,
Capacity 3A/250 VAC Sequence of events 20 events
Between contact and coil: 2500 VAC /
Isolation voltage min Phase Sequence Yes
Displacement Power
Output Frequency 1 Hz maximum factor Modbus read
Relay Type Electromagnetic relay Voltage crest factor Modbus read
Compliance Electrostatic Discharge IEC 61000-4-2 Current K factor Modbus read
Energy pulse output Threshold setting Trigger DO
Pulse width Selectable 200/100/60 ms Phase Angles 3 Phase Voltage / 3 Phase Current
Pulse Output kWh/kVarh Real-time Data Voltage, Current, Active power,
Pulse constant 0.001/0.01/0.1/1/10/100/1000 per pulse Reactive power, Apparent Power, Power
Compliance IEC62053-31 Class A. Factor, Frequency
Digital input Measurement Channel 3 channel for each: Voltage / Current
Number 4 (max) ** Optional Energy
Isolation voltage 2500 VAC (1 min) Energy Positive / Negative active, reactive,
Response Time 10 ms apparent energy ; Positive / Negative
Maximum Frequency 1kHz base wave active, reactive energy
Multi-tariff energy 4 tariff, 8 time period
Measuring circuit Demand
Measuring voltage inputs Real-time Demand fixed- and slide window record value
Rated range (L-L) 230V/400V(continuous: 1.2Un) Accuracy
Resolution 0.1 V Voltage/ Current ±0.2%
Re-,Active/Apparent
Impedance 1.6 MΩ/per phase power ±0.2%
Power consumption ≤0.1 VA /per phase Active Energy IEC 62053-22 Class 0.5S, IEC 61557-12 Class 0.5
Over voltage As per IEC61010-1 CAT III Reactive Energy IEC62053-23 Class 2, IEC 61557-12 Class 2
Frequency 45-65 Hz Power Factor ±0.01
Measuring current inputs Frequency ±0.1%
Rated range 5A/1A, (continuous: 1.2In) Memory
Resolution 5 mA Memory 120 KB
Impedance ≤20mΩ/per phase
Power consumption ≤0.2 VA/per phase
Over current 120A for 0.5Seconds

Product is tested and manufactured according to…


Electrostatic discharge immunity IEC 61000-4-2
Radiated, radio-frequency, electromagnetic field immunity IEC 61000-4-3
Electrical fast transient/burst immunity IEC 61000-4-4
Surge immunity IEC 61000-4-5
Immunity to conducted disturbances, induced by radio-frequency fields IEC 61000-4-6
Power frequency magnetic field immunity IEC 61000-4-8
Immunity to Voltage Dips IEC 61000-4-11
Radiated Emissions EN55011 Class A
Harmonics IEC 61000-3-2
Dimensions & Ordering Code

Ordering Code for GPM96-Series


G Eetarp Product Fixed Code
A A = IEC62053-22, M = MID Class
X Reserved
X Reserved
X Reserved
X C = MODBUS RTU, E = MODBUS TCP/IP
X B = Aux 65~480V AC / 80~660V DC, C = 24~48V DC, D = Self-power supply
X 5 = RS485, 6 = TCP/IP
X Reserved
3 = Demand Version + 15th harmonics version
4 = Demand + Min/Max + 63rd Harmonics Version + multi tariffs + DPF + Unbalance
X
5 = Basic Version
6 = MID, Multi-tariff with 63rd Harmonics Version
X X = No Ethernet Gateway, 1 = With Ethernet Gateway
X 2 = No DI/DO, 3 = 4 DI & 2 DO
X X = No Pulse Outputs, 2 = 2 Pulse Outputs
X Reserved
X = 1% - Basic version
X 0 = 0.5%
1 = 0.2%

Common GPM96 Variants


Order Number Type Features
GPM96 with 63rd harmonics, Multi Tariffs,
GMXXXCD5X6X22X0 GPM96-MID
Modbus RS485, MID Certified, 2 pulse output
GPM96 with basic electrical parameter, Modbus
GAXXXCB5X5X2XX0 GPM96-PK2
RS485, CL0.5S (Basic Model)
GPM96 with 63rd harmonics, Multi Tariffs,
GAXXXCB5X4X2XX0 GPM96-PK3
Modbus RS485, min/max, CL0.5S
GAXXXCB5X4X3XX0 GPM96-PK4 Basic Model + 4xDI, 2xDO
GAXXXEB6X4X2XX0 GPM96-PK5 Basic Model + Modbus TCP/IP
GAXXXEB6X4X3XX0 GPM96-PK6 Basic Model + 4xDI, 2xDO, Modbus TCP/IP
Basic Model + 4xDI, 2xDO, Modbus TCP/IP,
GAXXXEB6X413XX0 GPM96-PK7
Modbus Gateway
Document no.: EEPL-CAT-GPM96-rev14

Eetarp Engineering Pte Ltd Eetarp Power (M) Sdn Bhd

11 Woodlands Close, #08-13 | Woodlands 11 A-5-11, Blk Allamanda


Singapore 737853 10 Boulevard, Lebuhraya Sprint
Tel: +65 6339 3651 | Fax: +65 6339 3667 PJU 6A 47400, PJ | Selangor, Malaysia
Email: contact@eetarp.com Tel: +603 7729 3973 | Fax: +603 7729 8973
CRN: 200001617K E-Mail: contact@eetarp.com
CRN: 1205228 P

www.eetarp.com

You might also like