NMES

This document discusses neuromuscular electrical stimulation (NMES), including how it works, parameters used, applications, contraindications and precautions. NMES uses electrical pulses to cause muscle contractions and can increase strength, range of motion or assist functional tasks.

Uploaded by

Anandhu G
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
67 views16 pages

NMES

This document discusses neuromuscular electrical stimulation (NMES), including how it works, parameters used, applications, contraindications and precautions. NMES uses electrical pulses to cause muscle contractions and can increase strength, range of motion or assist functional tasks.

Uploaded by

Anandhu G
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

NMES

• Neuromuscular Electrical Stimulation (NMES) uses a device that sends


electrical impulses to nerves. This input causes muscles to contract

• The electrical stimulation can increase strength and range of motion, and
offset the effects of disuse

• It is often used to “re-train” or “re-educate” a muscle to function and to


build strength after a surgery or period of disuse.
• Generation of action potential in the circuit

Action potential travels down the neuron to the


motor end plate, where the sarco-plasmic
reticulum becomes depolarized , and ca is
released

Cross-bridge cycling between actin and myosin


filaments of the muscle results in overlapping of
sliding filaments , causing the muscle to shorten
(contract).
• Therapeutic NMES – Use of repetitive stimulation of activation of paralyzed
muscles to minimize specific impairments like limited ROM ,motor
weakness ,spasticity, cardiovascular de conditioning

• Functional NMES – Use of NMES to activate paralyzed muscle at a precised


sequence to assist in the performance of ADLs or to provide stability to a
joint or maintain biomechanical integrity and therefore function.

• Functional Electrical Stimulation or FES- FES involves the use of NMES to


activate muscles in a specific order and degree to complete a functional task.
Working of NMES
• An electric current is the directed flow of charged particles in some
conducting medium.
• Electric currents also occur naturally in human body, and for that there
are two conducting mediums : 1. ionic fluids 2. nerves
• Nerves are specialized , excitable tissues , designed to carry waves of
ion fluxes in the form of action potentials, action potentials carry the
impulses transmitted within the central and peripheral nervous system.
• Skeletal muscles are innervated by peripheral motor nerves organized
in a functional units known as Motor units
• The electrical current activates the motor units by inducing action
potentials in the motor nerve.
• Activation always takes place through the motor nerves because
the nerves are much more excitable . Intact motor nerve is a pre-
requisite for activating a muscle with NMES.
• Electrical waveforms used in NMES

1. Mono-phasic {one polarity only}

2. Biphasic {alternating polarity}

3. Pulsed {isolated pulses of current between which there is no current


flow}

4. Bursted {bursts of currents between which there is no current flow}


• Any of these waveforms can work well , but there are relative
advantages depending upon the application.

• Examples : Pulsed current , are especially useful for activating small


muscles.

• When there is a requirement of strong contractions of lower extremities


, biphasic waveforms will be more effective.
Stimulus parameters in nmes
• Pulse amplitude and duration control
• Both together regulates the charge of each pulse and so
determine the number of peripheral nerve fibers recruited with
each stimulus. •
• Amplitude control accompanies by balance control which
effectively shifts between the channels. As the balance control
is adjusted , the output amplitude on one channel rises while of
the other channel falls.
• optimal pulse duration likely lies between 50 and 1000
microseconds
• Frequency

• A train of electrically induced action potentials in rapid sucession will


result in corresponding series of twitches in targeted muscle.

• A frequency of 30-50 pulses per second produces a smooth tetanic


contraction.
INTENSITY
• Intensity in miliamperes varies with pulse duration.
• Short duration pulses require relatively higher intensities , where as
relatively low intensities are adequate with long-duration pulses.
• As intensity increases , force of contraction increases because more
motor units are recruited within motor nerve.
• Intensity should be tolerable for the subject as well as able to elicit
motor response.
Duty Cycle

• It is used to avoid fatigue.

• The off part allows ionic gradients and neurotransmitters to recover in


nerve and muscle.

• On : off ratio of 1:7 minimizes fatigue but its time consuming. And
ratio of 1:1 is rapid. So , 1:3 ratio is used clinically.

• 4 second of stimulation and 12 seconds of rest.


Ramping
• Ramp modulation controls are included in neuromuscular electrical
stimulation so that the pulse charge of phase of each stimulus may be
gradually increased or decreased.
• The gradual rise allows the gradual recruitment of nerve fiber and
comfortable initiation of contraction for subject.
• It is most effectively used in neurologically impaired patients.
• The gradual decline allows smooth movement.
Electrode size and placement
• If one of the electrode is smaller than other , the current density
will be greater under the electrode because the current pass
through a smaller area.
• Small electrodes are sometimes used to focus current over a
particular motor point, allowing isolated contraction in targeted
muscle.
• Larger electrodes are used for back region.
CONTRAINDICATION
• Unstable cardiac conditions
• Implanted pacemakers
• Acute danger or hemorrhage
• Acute danger of thromboembolism
Precautions
• Epilepsy
• Decreased sensation
• No stimulus over carotid sinus
• No stimulus across of through thorax
• No stimulus over larynx area
• Do not stimulate diseased skin
• Prosthetic joint motion restriction
• Avoid grounding faults