22.130 - A230 - Existing & Demo RCP

This document provides general notes regarding building code compliance for fire safety and accessibility requirements. It specifies that all exit doors and doors in the path of travel to exits must be operable from the inside without keys. It also requires electrical switches and controls to be located between 900mm and 1100mm above floor level. Fire safety systems like signs, hydrants and extinguishers must meet Australian standards.

Uploaded by

prlicines
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views1 page

22.130 - A230 - Existing & Demo RCP

This document provides general notes regarding building code compliance for fire safety and accessibility requirements. It specifies that all exit doors and doors in the path of travel to exits must be operable from the inside without keys. It also requires electrical switches and controls to be located between 900mm and 1100mm above floor level. Fire safety systems like signs, hydrants and extinguishers must meet Australian standards.

Uploaded by

prlicines
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GENERAL NOTES:

1. VERIFY ALL DIMENSION / SET OUT DIMENSIONS ON SITE PRIOR TO


CONSTRUCTION. IF ANY DISCREPANCIES ARE DETECTED, ADVISE
THE ARCHITECT IMMEDIATELY.
2. ALL EXIT DOORS AND DOORS IN THE PATH OF TRAVEL TO EXITS ARE
TO BE CAPABLE OF BEING OPERATED AT ALL TIMES BY A PERSON
SEEKING EGRESS FROM THE BUILDING WITH A SINGLE HANDED
DOWNWARD ACTION OR PUSHING ACTION ON A SINGLE DEVICE
WITHOUT THE USE OF A KEY AND LOCATED BETWEEN 900mm AND
1100mm ABOVE THE FINISHED FLOOR LEVEL IN ACCORDANCE WITH
CLAUSE D2.21 OF THE BUILDING CODE OF AUSTRALIA.
3. ALL ELECTRICAL SWITCHES, CONTROLS, INTERCOMS, ETC ARE TO
BE LOCATED BETWEEN 900mm AND 1100mm ABOVE FINISHED
FLOOR LEVEL AND NO CLOSER THAN 500mm FROM ANY INTERNAL
CORNER IN ACCORDANCE WITH CLAUSE 14.1 OF AS1428.1.
4. EXIT SIGNS AND EMERGENCY LIGHTS TO COMPLY WITH AS-2293.3.
FIRE INDICES OF MATERIALS, LININGS AND SURFACE FINISHES TO
COMPLY WITH SPECIFICATION C1.10 OF THE BUILDING CODE OF
AUSTRALIA.
5. ALL CONCRETE PANEL JOINTS WITHIN 3m OF ANY BOUNDARY ARE
TO HAVE FIRE RATED CALKING.
6. ALL MASONRY WALLS TO BE INSTALLED IN ACCORDANCE WITH
AS3700.
7. FIRE HYDRANT AND FIRE HOSE REEL INSTALLATIONS TO COMPLY
WITH AS-2419 AND AS-2441.
8. PORTABLE FIRE EXTINGUISHERS TO COMPLY WITH AS-2444.
PROVIDE DRY CHEMICAL FIRE EXTINGUISHER BETWEEN 2 & 20m
FROM EACH ELECTRICAL SWITCHBOARD, PLANT ROOM, KITCHEN
AND TEA AREA.
9. FIRE BLANKETS TO ALL KITCHENS AND KITCHENETTES. LOCATION
TO BE DETERMINED ON SITE.
10. MECHANICAL VENTILATION SYSTEM TO COMPLY WITH AS-1668.2
AND AS-3666. EXHAUST AIR OUTLETS NOT TO BE LOCATED CLOSER
THAN 6m TO FRESH AIR INLETS.
11. ALL GLAZING TO COMPLY WITH AS-1288. ANY NOMINATED GLAZING
THICKNESS ARE MINIMUM REQUIREMENTS ONLY. IT IS
RESPONSIBILITY OF THE GLAZIER / CONTRACTOR TO PROVIDE A
COMPLIANT INSTALLATION AND PRICED ACCORDINGLY.

PB 2383 PB 2383 12. ALL OPENINGS & FLOOR, WALL & ROOF JUNCTIONS MUST BE FULLY
SEALED AND CALKED TO PREVENT AIR LEAKAGE IN ACCORDANCE
R1A R1B WITH SECTION J3 OF THE BCA.

KITCHENETTE KITCHENETTE 13. ALL EXTERNAL OPENINGS (DOORS & OPERABLE WINDOWS) MUST
BE FITTED WITH DRAFT SEALS TO ALL SIDES OF OPENINGS.
6.25 SQM 6.53 SQM
14. ALL FULLY GLAZED DOORS, SIDE LIGHTS OR WALLS TO HAVE A
PB 2387 SOLID CONTRASTING LINE OF FILM ACROSS THE FULL EXTENT OF
THE GLAZING. 75mm THICK WITH THE LOWER EDGE BETWEEN 900 -
1000mm ABOVE FFL.

PB 2388 15. ALL WINDOW BLIND CORDS OR CHAINS ARE TO BE INSTALLED TO


HANG AT A MINIMUM 1600mm ABOVE FFL.
PB 3723
G09 16. ALL INTERNAL STEELWORK IS TO BE SHOP PRIMED. ALL EXTERNAL
OFFICE PRO STAFF STEELWORK EXPOSED TO THE WEATHER SHALL BE HOT DIP
GALVANISED UNLESS NOTED OTHERWISE.
16.14 SQM
G06 17. WATERPROOFING TO WALLS AND FLOORS TO WET AREAS TO BE
PROVIDED WHERE REQUIRED BY CLAUSE F1.7 IN ACCORDANCE
TYPE 2 COMMS WITH AS-3740.
1.97 SQM 18. ALL FLASHINGS & CAPPINGS TO BE POWDERCOATED WHERE
VISIBLE, ZINCALUME ELSEWHERE. PROFILED WEATHER STOPS TO
PB 2387 ALL ROOF AND WALL SHEETING.
G11 19. ALL ROOF PENETRATIONS ARE TO HAVE CONTINUOUS FLASHED

G04 ACC. WC FROM PENETRATION TO ROOF APEX.


4.00 SQM 20. FACADE SYSTEMS TO COMPLY WITH AND HAVE CURRENT
RECEPTION CODEMARK CERTIFICATION FOR COMPLIANCE WITH NCC: FP1.4 -
11.68 SQM FACADE WATERPROOFING CERTIFICATION.
21. BUILDING WRAP / SARKING MUST COMPLY WITH NCC C1.9(A)(i),(D)
&(E)(iV) - FIRE RESISTANCE (NON-COMBUSTIBLE BUILDING
ELEMENT)
22. DISABLED SANITARY FACILITY TO COMPLY IN ALL RESPECTS TO
AS-1428.1 - 2009.
23. ALL WALL HUNG FIXTURES AND FITTINGS INCLUDING HANDRAILS
AND WC BACK RESTS ARE TO BE FIXED DIRECTLY TO SUITABLE
TIMBER STUDS LOCATED SPECIFICALLY FOR SUCH SUPPORT.
STUDS TO BE LOCATED WITH 'STUD FINDER' PRIOR TO
PB 3723 PB 3309 PB 3723 INSTALLATION OF FIXTURE.
24. NON-LOADBEARING WALLS AND CEILINGS ARE TO BE INSTALLED TO
COMPLY WITH WITH AS1170.4 FOR SEISMIC LOADS.

G01 25. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE


ARCHITECTURAL SPECIFICATION AND ALL ITS APPENDICES,
LEASE - TBA COMMERCIAL INCLUDING (BUT NOT LIMITED TO) THE DOOR SCHEDULE, DOOR
HARDWARE SCHEDULE, COLOUR AND FINISHES SCHEDULE
61.10 SQM
(INTERNAL AND EXTERNAL), FIXTURES, FITTINGS AND APPLIANCES
SCHEDULE.

DEMOLITION NOTES:
1. CONTRACTOR IS TO ALLOW TO DEMOLISH ALL STRUCTURES &
TERMINATE ALL SERVICES ABOVE AND BELOW GROUND THAT ARE
NOT REQUIRED FOR PROPOSED WORKS. INCLUDE TO REMOVE ALL
REDUNDANT SERVICES, CABLES ETC. FROM COLUMNS, WALLS &
CEILINGS. MAKE GOOD ALL SURFACES ON COMPLETION.

2. CONTRACTOR TO CONFIRM LOCATIONS OF ALL EXISTING


IN-GROUND SERVICES PRIOR TO COMMENCEMENT OF WORKS.

3. CONFIRM ALL DOCUMENTATION/SET OUT DIMENSIONS ON SITE


PRIOR TO COMMENCING CONSTRUCTION. IF DIMENSIONS ON SITE
DIFFER FROM THOSE NOTED REFER TO ARCHITECT FOR
DIRECTION, PRIOR TO PROCEEDING.

4. ALL DEMOLITION WORKS ARE TO BE IN ACCORDANCE WITH AS2107


- 1994, AS2436 - 1981 & AS2601 - 1991. WORKS MUST COMPLY WITH
THE REQUIREMENTS OF THE BCA & LOCAL COUNCIL
REQUIREMENTS.

5. MAKE GOOD TO ANY DAMAGE TO STRUCTURES TO BE RETAINED


AND/OR ADJACENT TO PROPERTY WHICH RESULTS FROM
DEMOLITION OPERATIONS. ALL RESTORATION WORKS TO BE
PERFORMED AT NO EXPENSE TO THE PROPRIETOR.

6. PHOTOGRAPHIC DILAPIDATION SURVEY OF ALL ADJACENT WALLS,


FENCES, FOOT PATHS... TO BE COMPLETED PRIOR TO DEMOLITION
WORKS. PHOTOGRAPHIC RECORD TO BE FORWARDED TO CLIENT
AND ARCHITECT.

7. ANY DAMAGE TO PATHS, NATURE STRIPS, GARDEN BEDS etc. TO BE


MADE GOOD.

8. WHERE VINYL AND CARPET HAVE BEEN DEMOLISHED,


CONTRACTOR TO ALLOW FOR GRINDING OF GLUE AND
PREPARATION OF SURFACE IN ACCORDANCE WITH NEW COVERING
MANUFACTURERS SPECIFICATION.

GENERAL LEGEND:
EXISTING WALLS TO REMAIN.

NO WORKS

EXISTING TO BE DEMOLISHED

EXISTING SHOWN HATCHED TO BE


PARTIAL RETAINED AND RELOCATED.

NO. DATE REVISION BY CHK


DRAWING NO. DRAWING TITLE REV. STATUS PROJECT
P1 23.07.18 PRELIMINARY ISSUE PS NM
T1 23.08.05 TENDER ISSUE PS NM
A230 EXISTING &
DEMO RCP
T1 TENDER
ISSUE
UoM 800 SWANSTON ST

DATE DRAWN CHECKED JOB NO. SCALE PROPRIETOR NOTES


.
WWW.MILLARARCH.COM.AU
25.03.22 HM NM 21.130 1:50 @ A1 UNIVERSITY OF ALL WORK SHALL CONFORM TO THE SPECIFICATION AND OTHER INFO@MILLARARCH.COM.AU
RELEVANT DRAWINGS. FIGURED DIMENSIONS TAKE PRECEDENCE
1:100 @ A3 MELBOURNE OVER SCALED DIMENSIONS. CHECK ALL DIMENSIONS ON SITE. +61 3 7885 8554
SHOP DRAWINGS SHALL BE SUBMITTED TO THIS OFFICE FOR
APPROVAL BEFORE COMMENCEMENT OF ANY FABRICATION.
ACN 643 118 834