SPECIFICATIONS                                                      MEASUREMENT SOLUTIONS
Model 210 Digital
   Electro-Hydraulic Set-Stop                                                           We put you first.
   Bulletin SS03009 Issue/Rev. 1.0 (4/15)                                               And keep you ahead.
   SMITH METER® VALVES
   The Smith Meter Model 210 Valve is typically used in
   conjunction with either a Smith Meter AccuLoad® or
   microLoad Preset Controllers for loading and unloading
   at truck racks, bulk plants or processing installations.
                              FEATURES
      »» Simple control loop
      »» Control loop needle valves for tuning
      »» Low pressure drop
      »» Separate opening and closing speed control
      »» Compound spring
      »» Horizontal or vertical applications
                                                                OPERATION
      »» Full range of optional control functions
                                                                The Smith Meter Model 210 Valve is a Smith Meter 200
      »» 2" Reduced Port Valve – Ideal for renewable fuels
                                                                Series Valve with two solenoid controls (see Figure 1). The
         blending, controlling flow down to 3 GPM.
                                                                normally-open (N.O.) and normally-closed (N.C.) solenoids,
      »» Fail to close
                                                                located in the upstream and downstream portions of the
                                                                control loop, respectively, control the operation of the
                                                                valve. With both solenoids energized, high upstream
                                                                pressure is blocked allowing the product in the cover
          N.O.                                         N.C.     to vent to low downstream pressure, opening the main
        Solenoid                                     Solenoid
         (30B)                                        (30A)     valve. Conversely, de-energizing both solenoids allows
                                                                high upstream pressure to close the valve.
                                                                 Flow Rate GPM                         First Stage Trip*
                                                                  900
                                                                  600                                                      Final
                                                                             Gallons*                                   Stage Trip*
            Closing                        Opening                                         First High Flow Rate*
            Speed                           Speed
            Control                        Control                300
                                                                                                Second High Flow Rate*
                   Strainer                                                  Low Flow Start*
                                                                    0
                               Flow                                  2,000                                         60             0
                                                                                    Gallons to Be Delivered
   Figure 1 – Model 210 Valve Schematic
                                                                   *Field programmable.
                                                                  Caution: There must be sufficient pump capacity to achieve
                                                                  the flow rate set into the AccuLoad or microLoad or the valve
                                                                  may close slowly resulting in a spill.
                                                                Figure 2 – Typical Load Cycle
Energizing just the N.O. solenoids locks fluid in the valve                     SPECIFICATIONS
cover, which locks the valve poppet in a fixed position,
                                                                                Maximum Viscosity
to maintain a constant flow rate as long as operating con-
                                                                                200 SSU (40 mPa•s)1; Above 200 SSU, consult factory
ditions do not change. When operating conditions change,
causing a change in flow rate for that fixed valve opening,                     Pressure Rating/Connections2, 3, 4
the flow controller signals the appropriate solenoid to open                    Class 150 ASME, 285 psi (19.6 bar)
momentarily to readjust flow rate back to its set value.                        Class 300 ASME, 300 psi (20.7 bar)
When the set flow rate changes (e.g., from low flow start                       Temperature Range
to high flow limit, or during multi-step valve shutdown),
the appropriate solenoid is signalled to open until flow rate                    Valve Elastomer                 Temperature Range2, 5
adjusts to the new set value. See Figure 2 for a typical truck                   LS (Low Swell) Buna             -20°F to 200°F (-28°C to 93°C)
loading flow rate sequence.                                                      Buna-N                          -20°F to 200°F (-28°C to 93°C)
                                                                                 Viton                           -20°F to 350°F (-28°C to 177°C)
Located between each solenoid and the main valve port
is a valve response control device, typically a needle valve.                   Voltage (Solenoids)
This device is used to fine tune the opening and closing rate                   Standard: 120 VAC / 60 Hz or 110 VAC / 50 Hz
of the valve, as well as providing total control loop isolation
                                                                                Optional: 240 VAC / 60 Hz or 220 VAC / 50 Hz
for ease of service. Adjustment of these devices control the                    		24 VDC
flow to the cover chamber, permitting adjustments based                         		12 VDC
on product viscosities and pressures.                                           		        Other voltages, consult factory
PRESSURE DROP
(When valve is not flow-limiting or wide open)
                                                                           Flow Rate (L/min)
                             40         100            250         500     1,000       2,500        5,000   10,000       20,000
                        20
                        18                                                                                                           120
                                                                                          3"
                        16
                                                                                               4"    6"                              100
                                                                   2” RP
                        14
                                                                           2"
                        12                                                                                                           80
      Pressure Drop
           ∆P                                                                                                                              ∆P
           PSI          10                                                                                                                 kPa
                                                                                                                                     60
                         8
                         6                                                                                                           40
                         4
                                                                                                                                     20
                         2
                         0
                             10                   50         100           2    3 4 5 6 7 8 1,000           2   3    4    5 6 7 8 10,000
                                                                            Flow Rate (GPM)
  Notes: Assumes that a dual spring is used in 4" and 6" valves.
         Test fluid is kerosene with 0.82 sp. gr., 2 cP or mPa•s
         The 2" and 2" RP (Reduced Port Valve) have negligible pressure drop below 50 GPM when the valve is not flow limiting.
1 1 mPa•s = 1 cP.
2 Pressure ratings are based on temperatures of -20°F to 100°F (-28°C to 38°C). For operation at higher temperatures, the maximum working pressure
  may be derated.
3 PED requirements limit applications to liquids with maximum vapor pressures of .5 bar above atmospheric pressure, at maximum allow-
  able temperature.
4 PED required for all European countries. Equipment must be manufactured by our Ellerbek, Germany facility.
5 For temperature outside these ranges, consult factory.
6 Polytetrafluoroethylene (PTFE).
  2   Bulletin SS03009 Issue/Rev. 1.0 (4/15)
MATERIALS OF CONSTRUCTION                                                               WEIGHT
                   Housing           Internals              Seals                             Size                  lb.
 Main Valve                          Stainless              Low Swell                         2"                    46
                                     Steel,                 Buna7,
                   Cast Steel        Carbon Steel,          Viton-A or                        3"                    83
                                     Ni-Resist              Buna-N                            4"                    136
                                     Ductile Iron
                                                                                              6"                    260
 Solenoid                                                   Viton-F7,
 Valves            Stainless Steel   Stainless Steel        Buna-N,
                                                            Chemraz
 Needle
                   Steel9            Steel9                 Viton/ PTFE6
 Valves7
 Tubings and
                   Steel9            Steel9                         –
 Fittings
                                     Chrome Plated
 Ball Valves8      Steel9            Steel Ball/Steel       PTFE6
                                     Body
DIMENSIONS
Inches (mm)
                  A           A                                                 E       E
   Size         Class       Class       B10             C               D11   Class   Class
                 150         300                                               150     300
  2" and         8.0         8.5       8.0          4.0              7.5       3.0     3.3
  2" RP         (203)       (216)     (203)        (102)            (140)     (76)    (84)
                 11.0        11.8      9.5          4.0              9.5       3.8     4.1
    3"
                (279)       (300)     (241)        (102)            (241)     (97)    (104)
                 13.5        14.1      9.5          4.9              9.5       4.5     5.0
    4"
                (343)       (358)     (241)        (124)            (241)     (114)   (127)
                 17.0        17.9      11.0         6.6              12.5      5.5     6.3
    6"
                (432)       (455)     (279)        (168)            (318)     (140)   (160)
Note: Dimensions – Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned
from respective engineering drawings.
6 Polytetrafluoroethylene (PTFE).
7 Standard.
8 Optional (for 4" and 6" only)
9 Stainless steel ball valves and/or tubing and fittings available
10 Minimum, normal, maximum
11 Pilots and tubing will be within dimensions                                                       Bulletin SS03009 Issue/Rev. 1.0 (4/15)   3
                                                                                                                                  We put you first.
                                                                                                                                  And keep you ahead.
 Revisions included in SS03009 Issue/Rev. 1.0 (4/15):
 Page 1: General edits made to text
 Page 2: Text edits made to Specifications text.
 Page 3: Text edits made to Materials of Construction table, Footnotes changed from symbols to numbers, edits made to Dimensions diagram and table,
 Weight table added.
 The specifications contained herein are subject to change without notice and any user of said s pecifications should verify from the manufacturer that the specifications are currently
 in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which m
                                                                                                       ay have been changed and are no longer in effect.
 Contact information is subject to change. For the most current contact information, visit our website at www.fmctechnologies.com/measurementsolutions and click on the “Contact
 Us” link in the left-hand column.
                                                                                                                                                         USA Operation
                                                                                                                                                         1602 Wagner Avenue
                                                                                                                                                         Erie, Pennsylvania 16510 USA
                                                                                                                                                         P:+1 814.898.5000
                                                                                                   FMC Technologies
                                                                                                   Measurement Solutions, Inc.                           Germany Operation
                                                                                                   500 North Sam Houston Parkway West,                   Smith Meter GmbH
www.fmctechnologies.com/measurementsolutions                                                       Suite 100                                             Regentstrasse 1
                                                                                                   Houston, Texas 77067 USA                              25474 Ellerbek, Germany
© 2015 FMC Technologies. All rights reserved.   SS03009 Issue/Rev. 1.0 (4/15)                      P:+1 281.260.2190                                     P:+49 4101 304.0
                                                                                                                                                                                         4