100% found this document useful (1 vote)
341 views1,438 pages

Industrial Controls Catalog

This document appears to be the cover page and table of contents for the Siemens IC 10 2023 catalog for Industrial Controls. It lists 16 chapters that will be included in the catalog, such as introductions to industrial communication, switching devices, protection equipment, load feeders, motor starters, monitoring and control devices, safety technology, and power supplies. It also provides information on ordering from the catalog, such as standard delivery times, packaging sizes, price units, and price groups. The catalog is intended to contain all selection and order-relevant data for Siemens industrial control products.

Uploaded by

Gary Garzon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
341 views1,438 pages

Industrial Controls Catalog

This document appears to be the cover page and table of contents for the Siemens IC 10 2023 catalog for Industrial Controls. It lists 16 chapters that will be included in the catalog, such as introductions to industrial communication, switching devices, protection equipment, load feeders, motor starters, monitoring and control devices, safety technology, and power supplies. It also provides information on ordering from the catalog, such as standard delivery times, packaging sizes, price units, and price groups. The catalog is intended to contain all selection and order-relevant data for Siemens industrial control products.

Uploaded by

Gary Garzon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1438

© Siemens 2023

Catalog Edition
,&ϷϮ ϶Ϯ϶ϵ

SIRIUS

Industrial Controls
siemens.com/sirius
© Siemens 2023

Verwandte Kataloge
Related catalogs Miscellaneous

Industrial Controls IC 10 Industry Mall


SIRIUS Information and Ordering Platform
on the Internet:

PDF (E86060-K1010-A101-B5-7600) www.siemens.com/industrymall

Low-Voltage Power Distribution and LV 10 Siemens TIA Selection Tool


Electrical Installation Technology for the selection, configuration and ordering of
SENTRON • SIVACON • ALPHA TIA products and devices

PDF (E86060-K8280-A101-B6-7600) www.siemens.com/tst

SIMATIC ST 70 Contact
Products for Your personal contact can be found in our
Totally Integrated Automation Contacts Database at:

PDF (E86060-K4670-A101-B9-7600) www.siemens.com/automation-contact

Motion Control Drives D 31.2 Trademarks


SINAMICS Converters for Single-Axis Drives
Distributed Converters
All product designations may be registered trademarks or
product names of Siemens AG or other supplying companies.
PDF (E86060-K5531-A121-A2-7600) Third parties using these trademarks or product names for their
own purposes may infringe upon the rights of the trademark
SIMATIC Ident ID 10 owners.
Industrial Identification Systems Further information about industrial controls:
www.siemens.com/sirius

E86060-K8310-A101-B1-7600 Technical Support

SITOP KT 10.1
SITOP Expert technical support
Power Supply for Industrial controls:

PDF (E86060-D4001-A510-E0)
Support Request:
SITRAIN www.siemens.com/support-request
Digital Industry Academy

www.siemens.com/sitrain
© Siemens 2023

Industrial Controls
SIRIUS 1 Introduction

2 Industrial communication

3 Switching devices –
Contactors and contactor assemblies –
for switching motors

4 Switching devices –
Contactors and contactor assemblies –
Special applications

5 Switching devices –
Contactors and contactor assemblies –
Contactor relays and relays
Catalog IC 10 · 2023 6 Switching devices –
Soft starters and solid-state switching
Supersedes: devices
Catalog IC 10 · 01/2022
7 Protection equipment

Refer to the Industry Mall for regular updates of this catalog:


www.siemens.com/industrymall
8 Load feeders and motor starters
© Siemens 2023
for use in the control cabinet

9 Motor starters for use in the field,


high degree of protection

10 Monitoring and control devices

11 Safety technology

The catalog PDF contains click-on article numbers, graphics 12 Position and safety switches
and videos.

13 Commanding and signaling devices

14 Parameterization, configuration and


visualization with SIRIUS

The products and systems described in this


catalog are manufactured/distributed under
15 Power supply
application of a certified quality management
system in accordance with EN ISO 9001
(for the Certified Registration Nos., see
www.siemens.com/system-certificates/ep). 16 Appendix
The certificate is recognized by all IQNet
countries.
© Siemens 2023

Ordering notes
Catalog IC 10 contains all selection
and order-relevant data.

Ordering notes Standard delivery time (SD)


Ordering special versions Due to the current tight delivery situation on the market, no standard
For ordering products that differ from the versions listed in the delivery times are listed for our articles in this edition of the catalog.
catalog, the article number specified in the catalog must be Current information is given in the Mall for the respective article
supplemented with "-Z"; the required features must be specified by number at www.siemens.com/sirius/mall.
means of the alphanumeric order codes or in plain text. Packaging sizes (PS)
Small orders
The packaging size defines the number, e.g. of units, sets or meters,
When small orders are placed, the costs associated with order
contained in an outer packaging. Only the quantity defined by the
processing are greater than the order value. We recommend therefore
packaging size or a multiple thereof can be ordered. For multi-unit
that you combine several small orders. Where this is not possible,
packing and reusable packaging, see page 16/5 onwards.
we unfortunately have to charge a processing supplement of 20.00 €
to cover our costs for order processing and invoicing for all orders with Example
a net goods value of less than 250.00 € . 3RA2110-0FA15-1AP0
Price units (PU) PG: 41D
Order quantity 1 unit or a multiple thereof
The price unit defines the number of units, sets or meters to which
3RA1921-1D
the specified price applies.
PG: 41B
Price groups (PG) Order quantity 10 units or a multiple thereof
Each product is assigned to a price group. 3SU1900-0AB71-0AB0
Dimensions PG: 41J
Order quantity 10 units or a multiple thereof
All dimensions in mm.
Article No. Price PU PS* PG
per PU (UNIT,
SET, M)
3RA2110-0FA15-1AP0 1 1 unit 41D
3RA1921-1D 1 10 units 41B
3SU1900-0AB71-0AB0 100 10 units 41J

2 Siemens IC 10 · 2023
© Siemens 2023

SIRIUS in the
World Wide Web
The most important online services
at a glance.

Industrial controls Siemens Industry Online Support –


Homepage SIOS
www.siemens.com/sirius Product Support
www.siemens.com/online-support

Industry Mall Siemens Industry Online Support App


Catalog and Ordering System More information on the Online Support App
www.siemens.com/industrymall www.siemens.com/support-app

Configuring products and systems


Configurators
www.siemens.com/sirius/configurators

Device selection and configuration


TIA Selection Tool
www.siemens.com/tst

Siemens IC 10 · 2023 3
© Siemens 2023

SIRIUS 3RW
soft starters
As diverse as your tasks
The strong, harmonized portfolio of soft starters is suited
to a wide range of standard – and also Failsafe and
ATEX – applications thanks to comprehensive and specific
functions.
Benefit from intelligent functions such as condition monitoring,
automatic parameterization, pump cleaning and integrated
braking functions, regardless of the industry you are in.

Strong portfolio
Comprehensive, coordinated soft starter portfolio for simple to
demanding starting: Basic, General, High Performance

Efficient switching
Energy-efficient switching and mechanical protection of the
drive train thanks to soft starter with hybrid switching technology

Intelligent use
Concentrated, application-specific functionality thanks to
intelligent features such as automatic parameterization,
pump cleaning and condition monitoring

Ready for the digital future


Support for digital engineering processes with tools and data.
Data provision for local visualization or cloud-based analysis

4 Siemens IC 10 · 2023
© Siemens 2023

SIRIUS 3RW
Strong, comprehensive
portfolio with a wide
range of possibilities
thanks to a flexible
design.

More information, see


www.siemens.com/
softstarters

Digitalization
The 3RW soft starters
help you to realize the
full potential of
digitalization. This is
particularly beneficial
when it comes to
economic efficiency.

Your application in focus

IC01_00559
IC01_00555

IC01_00557

IC01_00558
IC01_00556

Pump cleaning Electrical Condition Automatic Integrated


and pump ruggedness monitoring parameterization braking functions
stopping mode
The pump cleaning Due to the wide control The condition monitoring Automatic parameterization Intelligent functions such
function prevents pumps voltage range from 110 function supports optimal simplifies the commissioning as soft starter braking
from blocking and to 250 V AC, soft starters planning of maintenance and operation of critical ensure a fast and reliable
therefore increases your have a high degree of work on bearings or seals, applications considerably, stop without engineering
productivity and system electrical ruggedness. thereby maximizing even in the case of highly and configuration work.
availability. The pump This guarantees reliable availability. dynamic load characteristics.
stopping mode avoids operation even in the
mechanical stress in the event of falling voltages.
piping system and extends
the service life of the
equipment.

Siemens IC 10 · 2023 5
© Siemens 2023

SIRIUS
modular system
Efficiently combined.

More information,
see
www.siemens.com/
sirius-modular-
system

Modular Save Order pre- Quick Efficient Use


design space assembled wiring configuration anywhere

Optimally matched Highest performance Ready-made and Comprehensive Configuration data Fulfills all relevant
and dimensioned on the market based tested combinations portfolio for spring- and macros for standards worldwide
products expandable on installation size with short-circuit loaded terminals, integration into your and requirements of
with uniform strength up to function blocks for CAE systems many applications
accessories 150 kA/400 V contactor assemblies even under extreme
for reversing operating conditions
and star-delta (safety applications,
(wye-delta) starting rail and shipbuilding,
as well as connectors etc.)

Sustainable switching and protecting AC-3e


Is IE3/IE4 ready and has the new utilization category AC-3e.
Ideal partner for switching and protecting highly efficient
motors

6 Siemens IC 10 · 2023
© Siemens 2023

TIA Selection Tool


quick, easy, smart configuration

For you to get the most out of our portfolio quickly and easily.

Do you always need the optimum


configuration for planning your project?
For your application we offer the TIA
Selection Tool to support all project
planners, beginners and experts alike.
No detailed portfolio knowledge is
necessary.
TIA Selection Tool is available for
download as a free desktop version or a
cloud variant.

Quick Easy Smart


• Configure a complete project with just • Tool download either as desktop • Smart selection wizard for error-free
a few entries – without a manual, version or web-based cloud version configuration and ordering
without special knowledge • Technically always up-to-date about • Configuration options can be tested
• Import and export of hardware product portfolio and innovative and simulated in advance
configuration to TIA Portal or other approaches • Library for archiving sample
systems • Highly flexible, secure, cross-team configurations
• Ideal visualization of the projects to work in the cloud
be configured • Direct ordering in the Siemens
Industry Mall

For more
information,
The TIA Selection Tool is a scan the QR code
completely paperless solution.
Download it now:
www.siemens.com/tst

Siemens IC 10 · 2023 7
© Siemens 2023

Smart Control Panel Design


The new standard in electrical engineering
With Control Panel Design, Siemens offers for the first time a function in the
TIA Selection Tool that can be used to design and dimension the main electrical
system of a machine in accordance with standards.
And this for the IEC standardization area and for the important North American market.

At the push of a button you receive the appropriate switching and protection devices
for your motor, including standard-compliant cable cross-sections and short-circuit
values for fuseless and fused load feeders.

Never before has the dimensioning of your load feeders been so quick and reliable!

Electrical engineering in ONE tool. This makes configuring more enjoyable!

1. 2.
Digital expertise on standards Easy dimensioning
IC01_00718

Standard conformity A new dimension


with no worries of dimensioning

3. 4.
Consistent workflow Supported portfolio
Electrical engineering Intelligent devices for
with unlimited creativity versatile solutions

Highlights
• Automatic short-circuit calculation and cable dimensioning
• Automatic dimensioning of fuseless and fused load feeders up to 250 hp
according to UL 508A or up to 250 kW according to IEC 60204-1
• Selection of the appropriate switching and protection devices for the motor
• Visual planning of the main circuit in the single-line diagram
• Simple accessory selection
• Complete PDF documentation of technical specifications and calculation results
(e.g. for the short-circuit verification)
• Simple main switch dimensioning for IEC and UL infeeds

8 Siemens IC 10 · 2023
© Siemens 2023

For more
information,
tool download
and videos, see
www.siemens.com/
cpd

Are you looking for a clear and easy way to dimension your circuits?

Or do you need suitable accessories for your switching devices?

The main circuit view with single-line display and the automatic display of accessories
are two of the many new functions in the TIA Selection Tool.

Siemens IC 10 · 2023 9
© Siemens 2023

Integrated
Control Panels
The easy way to build the
optimum control panel.
We offer practical support in mastering the typical challenges
of control panel engineering through a harmonized product
portfolio, tools and data for digitalization in engineering,
and expert know-how.

Working together for simple and Expert know-how


stress-free control panel design
Comprehensive support for all control panel The faster route to the ideal control panel
applications with practice-oriented expertise
Want to save time and costs? With Integrated Control Panels, We support you with exactly the right know-how to give you
it's easy to optimize all aspects of control panel building for your a competitive edge – both now and in the future. This includes
machines and industrial plants. From preparation and dimensioning, applying standards and guidelines in day-to-day operations
design and construction, through to service and support – for greater (e.g. UL 508A, IEC 60204-1) as well as efficient engineering and
competitiveness and long-term success. configuration.
• Webinars, online trainings and individual consulting on product
and application topics
• Literature with practical tips and tricks, including:
guidelines, product manuals, white papers
www.siemens.com/controlpanel/infocenter

10 Siemens IC 10 · 2023
© Siemens 2023

For more
information, see
www.siemens.com/
panelbuilding

Tools & data for digitalization Harmonized product and


in engineering system portfolio
Maximum efficiency for control panel design Effective savings in control cabinet design

With a range of tools and data-based services, we support you with Harmonized product and system portfolio saves construction time.
the digitalization of your business and enable the leverage of all the With our coordinated, integrated portfolio of products
advantages this offers for control panel design: greater efficiency, that includes automation technology, drive train components,
flexibility and quality – in every process phase! industrial controls and matching control panel enclosures, we can
• Intelligent selection, dimensioning and design reduce your engineering overhead and ensure the harmonious
www.siemens.com/controlpanel/cpd interaction of all devices. These are extensively tested, and are all
www.siemens.com/controlpanel/tools certified and available for use worldwide – enabling you to remain
• Control panel engineering flexible within the global business environment.
www.siemens.com/controlpanel/engineering Benefit also from our expert tips concerning control panels.
www.siemens.com/controlpanel/tips

Siemens IC 10 · 2023 11
© Siemens 2023

Product
highlights

SIRIUS 3RW5 soft starters 3RW55 system redundancy S2 SIRIUS 3RQ1 force-guided coupling
can be flexibly deployed in many for PROFINET High-Feature relays, fail-safe up to SIL 3/PL e
applications communications module
Type: 3RW5 Type: 3RW5950-0CH00 Type: 3RQ1
Pages 6/15, 6/39, 6/55 and 6/73 onwards Page 6/10 onwards Page 5/21 onwards

3SE64 RFID safety switches Electronically configurable 8WD46


with tumbler signaling columns

Type: 3SE6415-1... Type: 8WD4613, 8WD4615


Page 12/122 onwards Page 13/163 onwards

For more
information, see
www.siemens.com/
sirius

12 Siemens IC 10 · 2023
© Siemens 2023

Sustainability@SI
An intelligent infrastructure is
a sustainable infrastructure.

For more
information, see
www.siemens.com/
sustainability-
figures

As a company, Siemens considers environmental, social and governance (ESG) criteria from all angles with its DEGREE
framework (decarbonization, ethics, governance, resource efficiency, equity and employability). We are not only
committed to reducing the carbon footprint in our own operations to net zero by 2030, but also helping our customers
achieve their decarbonization and sustainability goals. The main areas where Smart Infrastructure contributes to the
DEGREE framework are decarbonization, resource efficiency and employability.

Mission & strategy Technology with aim Our contribution Sustainability facts
and purpose
As a focused technology We develop technologies that Siemens makes an impact every For almost 175 years, Siemens
company, Siemens is committed connect the real and digital day by providing innovative has been driven by the desire
to addressing the world's most worlds and enable our solutions in response to to improve the lives of people
profound challenges by customers to positively challenges relating to around the world with our
leveraging the synergies between transform the industries that environmental protection, technologies.
digitalization and sustainability. form the backbone of our decarbonization, health and
economy: industry, safety. Innovative solutions that
infrastructure, transportation have a clear goal: to make the
and healthcare. world more sustainable,
more integrative and a better
place to live.

Siemens IC 10 · 2023 13
© Siemens 2023

Technical Support
One click – and you have all
the information you need.

Industry Online Support –


get fast and up-to-date information online
www.siemens.com/online-support
In Industry Online Support you will find FAQs,
manuals, certificates, applications & tools, and much more

Support Request –
the fast track to the experts
www.siemens.com/support-request
Using the Support Request form in Online Support you can
send your query directly to Technical Support.

Conversion tool –
the easy and efficient way to find successor
products
www.siemens.com/conversion-tool

Any more questions? figuring


Competent and fast technical
C on Or
de advice regarding:
ri
Our experts are there to ● Product selection
g

ng
in
nn

help you with competent ● Conversion from old to new


Pl a

technical advice.
Technical ● Competitor conversion
is si o nin g

● Special versions
Infor m

Support ● Particular requirements


mm
338c

● Commissioning
ati

_00
Co
on

● Maintenance
01
IC

Se
r vi Further input channel for other topics:
ce ion
O p e r at
Support Request: ● Returned goods

www.siemens.com/support-request ● Field Service assignments


● Corrective maintenance needs
● Quality cases

14 Siemens IC 10 · 2023
1
© Siemens 2023

Introduction

1
Energy-efficient controls
1/2 SIRIUS brings down energy costs

Energy management with SIRIUS


1/3 Integration into energy management
software

Systematic industrial safety


technology
1/4 SIRIUS Safety Integrated

IE3/IE4 ready
1/8 SIRIUS controls for reliable switching
and protection of highly efficient IE3 and
IE4 motors

Innovative technology for saving


energy
1/9 Electronic starting with hybrid switching
technology

Siemens IC 10 · 2023
© Siemens 2023

Introduction
Energy-efficient controls
SIRIUS brings down energy costs
1

■ Overview
Energy management in industry
Whether you are a plant
operator, planner or machine
Third party applications manufacturer: Energy-
Cloud-based, open IoT operating system: efficient production is
MindSphere a challenge and an
Product opportunity in equal
manufacturer's measure.
perspective
1 Product
design

Machine
2 Production
planning

Machine
3 Production
engineering

Machine
4 Production
execution

Machine
5 Service

Machine
Machine concept engineering commis- operation service

IC01_00550
manufacturer's sioning
perspective
Collaboration platform: Teamcenter

Suppliers and logistics

Product development and production process

Energy-efficient production as a success factor Energy data acquisition represents an important component of
the overall energy data management process here. Through
In order to harness energy potential, with our vast portfolio, transparency right down to the loads, it is possible to identify and
we always maintain a clear view of the overall product utilize potential energy savings.
development and production process. Because maximum
energy efficiency in production can only be achieved through With communication-capable SIRIUS switching devices you can
perfect interaction of all components. acquire energy data from the drive train without any additional
effort.
That is why it is important to first create an awareness for existing
energy-saving potential, recognize (identify) and assess SIRIUS controls help you make energy flows visible.
(evaluate) opportunities for optimization through precise Best drive solutions in terms of energy
analysis. Finally, appropriate measures must be implemented
(realized). In order to design processes for optimal energy efficiency,
it is not enough to simply measure the energy flow and deploy
With our full-range portfolio of energy-efficient drive solutions, energy-efficient products. The greatest lever for saving energy
automation and services, you too will reach maximum energy can be derived from closely examining the application.
efficiency, higher productivity and lasting competitiveness in
your company. SinaSave energy efficiency tool

SIRIUS

Energy-efficient Energy-measuring Energy-optimized


products products drive solutions

up to

60%
energy saving

The Increasingly Biggest lever for


important with Amortization calculator for energy-efficient drive systems
Siemens energy savings
regard to energy
standard management acc. to The SinaSave energy efficiency tool determines energy saving
ISO 50001 potential and amortization times based on your individual
IC01_00245a
conditions of use and therefore offers practical assistance
in making decisions about investments in energy-efficient
Three columns of energy efficiency with products from the technologies.
SIRIUS modular system
In SinaSave, the drive systems to be compared and the
Energy-efficient products – SIRIUS reduces power loss relevant drive component parameters are displayed graphically.
SIRIUS controls (3RM motor starter, 3RR2 monitoring relay, 3RB3 The various control types and comprehensive product
overload relay, 3RT2 contactor, 3RW soft starter and 3RV2 motor combinations for drive solutions for pump and fan applications
starter protector/circuit breaker) as well as the ET 200SP motor can be adapted in your application.
starters are characterized by extremely low intrinsic power loss. The product portfolio comprises not just SIRIUS controls,
This not only lowers energy costs, but also reduces the amount but also SIMOTICS motors and SINAMICS converters, thus
of waste heat in the control cabinet. This then translates to offering a comprehensive range of comparison possibilities –
a higher packing density and a reduction in the required cooling according to your individual requirements.
performance. SinaSave, the free amortization calculator for energy-efficient
Energy-measuring products drives, see www.siemens.com/sinasave.
Energy management can be instrumental in increasing plant
productivity to bring about a significant improvement to the
competitive ability of a company – in all industries.

1/2 Siemens IC 10 · 2023


© Siemens 2023

Introduction
Energy management with SIRIUS
Integration into energy management software

1
■ Overview
SIMATIC Energy Suite SENTRON powermanager
High energy consumption and automated production processes
are typical for many industries.
If you want to keep your energy costs under control in the
long term and you are already focusing on the digital future,
it's a good idea to equip your plant with integrated energy
measuring technology, thus anchoring energy management into
the automation of your production processes – which is where
most energy is consumed.
SIMATIC Energy Suite as an integrated option for the TIA Portal
efficiently links energy management with automation, thus
creating energy transparency in the production system.
The considerably simplified configuration of energy measuring
components from the product families SIMATIC, SENTRON,
SINAMICS, SIRIUS and SIMOCODE significantly reduces the
configuration costs. For details on the currently supported
devices, see www.siemens.com/energysuite-hardware.
SENTRON powermanager
Thanks to the end-to-end connection to SIMATIC Energy The SENTRON powermanager energy monitoring software
Manager PRO (innovative successor to SIMATIC B.Data) or displays important characteristic quantities for individual
cloud-based Service Energy Analytics, you can seamlessly devices and the entire system on a clearly organized dashboard
expand the recorded energy data to create a cross-site energy and thus analyzes the energy consumption.
management system.
The advantages at a glance:
This also enables companies to fulfill all economic and energy
management requirements – from purchasing of energy through • Analyzing energy flows: Cost-saving measures can be
planning to energy management. derived directly and faults can be localized rapidly – for
greater awareness regarding energy consumption and
The advantages at a glance: lower costs.
• Simple and intuitive configuration instead of programming • Easy to get started: Can be added to existing hardware and
• Automatic generation of the PLC energy program available infrastructure.
• Convenient integration of measuring components from • Fast savings: Analyzes power curve and detects load peaks.
the Siemens portfolio and from the portfolios of other • High plant availability: Continuous monitoring of power
manufacturers distribution ensures that critical system states are detected
• Integrated in the TIA Portal and automation at an early stage.
• Archiving on WinCC Professional or PLC The SIRIUS 3RW55 soft starter is integrated into SENTRON
• Seamless connection to Energy Manager PRO and powermanager by simple installation of an XML file, see
Energy Analytics https://support.industry.siemens.com/cs/ww/en/view/109798105
For more information on SIMATIC Energy Suite, see For more information on SENTRON powermanager, see
www.siemens.com/energysuite. www.siemens.com/powermanager.

Siemens IC 10 · 2023 1/3


© Siemens 2023

Introduction
Systematic industrial safety technology
SIRIUS Safety Integrated
1

■ Overview

Detecting Evaluating Reacting

3SE5 3SE63 3SK 3RT1 3RT2


safety RFID safety safety relay contactor contactor
switch switch

3SE53 3SE64 SIMOCODE pro 3RW55 3RM1


safety RFID safety 3UF7 Failsafe soft starter motor starter
switch switch with
with tumbler tumbler

3SE66, 3SE67 SIRIUS ACT ET 200SP with 3RK1308 3RQ1


magnetically 3SU1 CM AS-i Master ST and ET 200SP coupling relay
operated switches EMERGENCY F-CM AS-i Safety ST motor starter
STOP 3RK7

3SE7 SIRIUS ACT 3TK2810 3RK1304


cable-operated 3SU1 standstill and ET 200pro motor starter
switch two-hand operation speed monitor
console

3RK1 3SE29
ASIsafe compact safety
module foot switch

Electronically
configurable 8WD46
signaling column
3RK1
ASIsafe
SlimLine
IC01_00695b

Compact
module

SIRIUS Safety Integrated


Manufacturers and operators of machines must fulfill To guarantee conformity with these requirements, it is
numerous requirements: reducing costs, improving productivity, recommended that the correspondingly harmonized
and ensuring the safety of machines. The industrial safety standards IEC 62061 or ISO 13849-1 are applied. This gives
technology from Siemens offers innovative, economical manufacturers and operators legal certainty regarding
solutions for the functional safety of machinery. compliance with both national regulations and directives,
which are confirmed by the manufacturer of a machine.
Machine safety – compliance with directives
The aim of safety technology is therefore to allow people,
Before any machines or plants can be supplied or operated, machines and the environment to be protected and statutory
they must meet the fundamental safety requirements of the safety requirements to be satisfied.
EU Directives. Similar requirements apply in many other
countries and markets.

1/4 Siemens IC 10 · 2023


© Siemens 2023

Introduction
Systematic industrial safety technology
SIRIUS Safety Integrated

1
The quick and easy way to safe machinery Your partner for machine and plant safety
In addition to the statutory regulations governing the protection With Safety Integrated, Siemens has provided the smart answer
of people there are also economic reasons for avoiding personal to constantly increasing requirements for the functional safety of
injury and the resulting downtimes, and for protecting both a machine and for its cost-effectiveness and flexibility. Our
machinery and equipment from damage. comprehensive portfolio of safe controls, control technology
and drive technology provides scalable solutions for precisely
Safety Integrated benefits machine manufacturers and plant tailored safety concepts for protecting people, machines
operators in many ways: and the environment. Our products meet the current safety
• Lower costs for hardware, assembly and engineering standards in the industry, including IEC, ISO, NFPA and UL.
• Higher availability thanks to faster diagnostics and fewer As a partner for machine and plant safety, Siemens also
downtimes supports users with examples of functions and up-to-date
At the same time, using modular safety concepts allows them to know-how concerning international standards and directives.
modernize their plants more easily and at lower cost. The Safety Selector (www.siemens.com/safety-selector) thus
guides the user to the appropriate application example based
Smart controls ensure the functional safety of machinery on selection criteria to be assigned.
Our SIRIUS Safety Integrated controls are a central element of The free safety evaluation for evaluating safety functions in
the Siemens Safety Integrated concept, based on Totally accordance with IEC 62061 and ISO 13849-1 is integrated in the
Integrated Automation. TIA Selection Tool, see www.siemens.com/safety-evaluation.
SIRIUS Safety Integrated, see Thus, the selection of components and their safety-related
www.siemens.com/safety-integrated. assessment are implemented in a coherent workflow.
Whether for reliable detecting, evaluating and reacting, our Requirements-based training on CE marking, functional safety,
SIRIUS Safety Integrated controls (page 1/6 onwards) provide risk assessment, and on our Safety Integrated products rounds
cost-effective solutions for the safety of your machine or plant. off our portfolio, see www.siemens.com/sitrain.
Take the SIRIUS 3SK safety relays for example: They are
modularly expandable, and can integrate compact motor
starters such as the fail-safe SIRIUS 3RM1 very simply via the
device connector (parameterization is performed easily with
a screwdriver on the DIP switches or by drag and drop in the
engineering software).
The SIMOCODE pro modular motor management system
combines all required protection, monitoring, safety and control
functions for motor feeders. It can be connected to fail-safe
controllers via PROFIBUS or PROFINET and shut down motors
in emergency situations.
SIRIUS Safety Integrated uses fail-safe communication via
standard fieldbus systems, such as ASIsafe via AS-Interface
and PROFIsafe via PROFIBUS and PROFINET, to solve even
networked safety tasks of greater complexity. This opens the
door to flexible safety solutions for compact machines or large-
scale plants – naturally compliant with current standards up to
SIL 3/PL e.
The first integrated ASIsafe connection to the distributed
I/O system ensures even more consistency. With the
SIMATIC AS-i F-Links, AS-i networks can be connected
quite simply to safety controls via PROFIsafe via the
SIMATIC ET 200SP.
Particular highlights are the 3RT contactors
of sizes S2 to S12 with fail-safe control input, the
SIRIUS ACT 3SU1 EMERGENCY STOP with PROFINET or
PROFIsafe interface, and the fail-safe motor starters for
ET 200SP (page 8/94 onwards) and the 3RW55 fail-safe soft
starters (page 6/39 onwards). With these products, seamless
integration into fail-safe control systems is possible.
The Application Manual SIRIUS Safety Integrated
(SIAM Safety Integrated Application Manual) provides
users with comprehensive application examples for
SIRIUS Safety Integrated products, see
https://support.industry.siemens.com/cs/ww/en/view/81366718.

Siemens IC 10 · 2023 1/5


© Siemens 2023

Introduction
Systematic industrial safety technology
SIRIUS Safety Integrated
1

Devices with safety functions


Detecting Evaluating Reacting
Product Page Product Page Product Page
3SE position and safety switches 12/2 SIMOCODE pro 3UF7 10/5 3RQ1 coupling relays 5/21

Flexible thanks to modular design, Fail-safe expansion modules SIRIUS 3RQ1 force-guided coupling
suitable for offshore applications DM-F Local and DM-F PROFIsafe, safe relays, fail-safe up to SIL 3/PL e
shutdown of motors up to SIL 3/PL e
3SE6 non-contact safety switches 12/4 3SK safety relays 11/13 3RW55 Failsafe soft starters 6/39

Magnetically operated switches (IP67) Key modules of a consistent and cost- 3RW55 Failsafe High Performance soft
and RFID safety switches (IP69) effective safety chain. Flexible thanks to starters with STO
input and output expansion units
3SU11 EMERGENCY STOP mushroom 13/26, 3TK2810 safety relays 11/33 SIRIUS 3RM1 motor starters 8/83
pushbuttons, 3SU18 two-hand 13/50,
operation console 13/106

• SIRIUS ACT two-hand operation console Further modules of a consistent and cost- Compact, narrow and fail-safe hybrid
with user-friendly capacitive sensor keys effective safety chain for fail-safe detection motor starters in IP20
• High level of flexibility due of standstill or speed Easy configuration and low outlay for
to direct integration of the storage thanks to wide setting range of
SIRIUS ACT EMERGENCY STOP via the overload release
standardized, fail-safe communication
protocols (PROFIsafe, ASIsafe)
3SE7 cable-operated switches, 13/156, ET 200SP fail-safe motor starters 8/94
3SE29 safety foot switches 13/161

• Foot switches with cover, metal Compact, fail-safe hybrid motor starters
enclosure with degree of protection IP65 for the ET 200SP system
• Cable-operated switches with latching
and positive-opening NC contacts,
in degree of protection IP65 or IP67

1/6 Siemens IC 10 · 2023


© Siemens 2023

Introduction
Systematic industrial safety technology
SIRIUS Safety Integrated

1
Devices with safety functions for AS-Interface
Detecting Evaluating Reacting
Product Page Product Page Product Page
Safety modules/EMERGENCY STOP CM AS-i Master ST, 2/29, ET 200pro Safety motor starters 9/3
mushroom pushbuttons F-CM AS-i Safety ST 2/34 Solution PROFIsafe
for SIMATIC ET 200SP
• K45F and K20F compact safety 2/26
modules for use in the field

• SC17.5F SlimLine Compact safety 2/26 Evaluation and processing of signals via Communication-capable motor starters
modules for use in the control cabinet a fail-safe SIMATIC or SINUMERIK with high degree of protection IP65
control. Special safety modules enable the
Simple combination of the highest safety levels
CM AS-i Master ST and
F-CM AS-i Safety ST modules in one
ET 200SP station results in a powerful, 3RT contactors from 18.5 kW
safety-oriented network transition (F-PLC input)
between PROFINET (or PROFIBUS)
and AS-Interface.

• 3SU1 EMERGENCY STOP mushroom 13/100


pushbuttons in the enclosure for
AS-Interface

Optimum connection to the fail-safe


controller as actuator in the safety chain
Considerable simplification of the
Detection of safety-related signals via application in large power ranges
safe input slaves on the AS-Interface bus thanks to F-PLC input on the following
(field modules with degree of protection contactors:
IP67, control cabinet modules
with degree of protection IP20, 3RT203 and 3RT204, 3/62,
EMERGENCY STOP mushroom 3RT105 to 3RT107, 3/65,
pushbuttons in the enclosure with 3RT145 to 3RT147 4/18
integrated ASIsafe slave with degree
of protection IP69)
3SF1 mechanical safety switches 12/93 Electronically configurable 8WD46 13/163
signaling columns

Flexible thanks to modular design, Flexible and versatile thanks to modular


degree of protection up to IP69, design
suitable for offshore applications

Siemens IC 10 · 2023 1/7


© Siemens 2023

Introduction
IE3/IE4 ready
SIRIUS controls for reliable switching and protection of highly efficient IE3 and IE4 motors
1

■ Overview

IE3- and IE4-compliant This is why we have optimized our


motors SIRIUS switching devices for IE3 and IE4 motors

SIRIUS controls
P E

consume For example Reliable


less energy switching and
protection of
inrush current motors
startup current at all times
IE3/IE
rated current 4

IC01_00482d
No false tripping Reliable switching capacity
but are characterized by
higher currents during startup process for use with IE3 and IE4 motors Are you IE3/IE4 ready?
during starting

IE3/IE4 ready with SIRIUS controls

We are IE3/IE4 ready and have AC-3e values Highlights


On July 1, 2021, the new EU Regulation (EU) 2019/1781 • Comprehensive range of IE3 and IE4 motors for every
on electric motors and speed controls came into force. application
This regulation requires: • Siemens offers expertise through extensive analysis of IE3
• Compliance with the legally required minimum efficiency and IE4 motors
levels IE3 for outputs from 0.75 to 1000 kW • Optimized SIRIUS controls for use with IE3 and IE4 motors
In the next stage as of July 1, 2023: • Easy selection thanks to consistently identical rated values of
• Compliance with the legally required minimum efficiency utilization categories AC-3 and AC-3e
levels IE4 for outputs between 75 and 200 kW. Introduction of utilization category AC-3e
From an electrical viewpoint, IE3 and IE4 motors behave
differently than less energy-efficient models – they are
characterized by higher startup currents and modified dynamic
behavior. This entails certain challenges for our controls.
The SIRIUS switching and protection devices are ideally suited
for use with Premium High Efficiency motors (IE3) or Super Video: What is the purpose of the utilization category AC-3e?
Premium Efficiency motors (IE4). This is further underlined by the
new utilization category AC-3e for contactors, circuit breakers, More information
motor starters and other devices. Application Manual for controls with IE3 and IE4 motors, see
They avoid false tripping due to higher inrush currents of IE3 and https://support.industry.siemens.com/cs/ww/en/view/94770820.
IE4 motors, offer optimized setting ranges for rated currents, and All IE3/IE4 ready products are marked in the catalog with the
ensure reliable switching and protection in any situation – the symbol E3 ready IE4 ready IE3/IE4 ready .
best prerequisites for the use of modern IE3 and IE4 motors.
All products with the utilization category AC-3e are marked in the
catalog with the symbol AC-3e .

1/8 Siemens IC 10 · 2023


© Siemens 2023

Introduction
Innovative technology for saving energy
Electronic starting with hybrid switching technology

1
■ Overview
SIRIUS 3RV29 infeed system with 3RA2 load feeder and 3RM1 motor starter

Compact
Simple
Only 22.5 mm wide,
Minimum wiring in the main and regardless of whether
control circuits thanks to direct-on-line or reversing
assembly option starter function

IC01_00526
Economical
Thanks to low device variance due
to wide setting range
Long service life
Hybrid switching technology
uses benefits of relay and
semiconductor technology
Safety
Safe switching possible with F-CPU
or SIRIUS 3SK safety relays

The hybrid switching technology uses low-wear semiconductor Further energy savings are provided by the integrated electronic
technology for switching the motor on and off, and in the overload protection.
operating phase it relies on energy-saving relay technology.
This causes a lower intrinsic power loss than comparable motor
This ensures durability, especially with high switching frequency, feeders with thermal overload protection.
and thus significantly reduces maintenance costs and extends
the life of the motor starters. In this way, you benefit from reduced heat generation and
therefore lower cooling power. And that saves energy.
In addition, due to the hybrid switching technology, motor
starters have lower electromagnetic interference emissions,
enabling you to increase your plant availability.

SIRIUS soft starters 3RW30, 3RW40, 3RW50,3RW52, 3RW55 and 3RW55 Failsafe
Safe
SIL 1/STO without additional
safety relay or contactor
Long service life
Reduced mechanical and
electrical load
IC01_00528d

Energy saving
Reduced temperature rise in the
control cabinet thanks to
bypass contacts
Simple
Fast and easy commissioning

Siemens IC 10 · 2023 1/9


© Siemens 2023

Introduction
Innovative technology for saving energy
Electronic starting with hybrid switching technology
1

Highlights
Use of hybrid switching technology for:
• SIRIUS 3RM1 motor starters
• ET 200SP motor starters
• SIRIUS soft starters
Failsafe functionality for SIRIUS 3RW55 soft starters,
SIRIUS 3RM1 motor starters and ET 200SP:
• Maximum safety:
Safety function up to SIL 3/PL e
Additional benefits for SIRIUS 3RM1 motor starters:
Easy to wire • Using device connectors safety-related group shutdown
Thanks to push-in technology with reduced wiring is possible
Option handling • Direct connection to the 3SK safety relay, without
additional wiring
IC01_00527
Increased flexibility and
efficient savings through
single configuration of complex
automation projects

Reduced space requirements


50% slimmer than other distributed I/O systems
Hybrid switching technology
Durable and energy saving, since relay contacts are not subject to
loading when switched

IC01_00529
Power bus
Supply with power only once, then automatic setup with side-by-side
mounting of multiple modules
Quick stop and end position disconnection
Load switch off even at high Switch on Operation Switch off
speed – independent of central controller
Quick installation Service life
Hook in, slide into place and engage
Plant availability

Once it is installed and wired, you simply connect the Energy saving
ET200SP motor starter to the controller in the
TIA Portal ready for parameterization.

1/10 Siemens IC 10 · 2023


2
© Siemens 2023

Industrial communication

Price groups Slaves


PG 212, 219, 230, 250, 254, 255, 256, I/O modules for use in the field, high
257, 41B, 41L, 42C, 42D, 5K1, 5K2 degree of protection
2/44 - Digital I/O modules, IP67 - Introduction

2
Introduction 2/45 - Digital I/O modules, IP67 - K60
2/3 AS-Interface 2/47 - Digital I/O modules, IP68/IP69 - K60R
2/13 IO-Link 2/50 - Digital I/O modules, IP67 - K45
2/52 - Digital I/O modules, IP67 - K20
AS-Interface
2/54 - Analog I/O modules, IP67 - K60
Introduction
I/O modules for use in the control
2/19 Communications overview cabinet
2/21 System components 2/57 - Introduction
AS-Interface specification 2/58 - SlimLine Compact
2/22 - Specification V3.0 2/62 - F90 module
2/23 - AS-i Power24V 2/63 - Flat module
ASIsafe Modules with special functions
2/24 Introduction 2/64 - Counter modules
2/25 AS-i safety solution with F-CPU and 2/65 - Ground-fault detection modules
AS-i in ET 200SP 2/66 - Overvoltage protection modules
2/34 F-CM AS-i Safety ST for Contactors and contactor assemblies
SIMATIC ET 200SP 3/18 - SIRIUS 3RT contactors, 3-pole up to
2/26 AS-Interface safety modules 250 kW
12/93 SIRIUS 3SF1 mechanical safety 3/142 - SIRIUS 3RA23 reversing contactor
switches for AS-Interface assemblies, up to 55 kW
SIRIUS ACT pushbuttons and indicator 3/158 - SIRIUS 3RA24 contactor assemblies
lights for star-delta (wye-delta) starting, up to
90 kW
13/88 - Modules: AS-Interface modules for
mounting on the front plate or in the 3/101 - SIRIUS 3RA27 function modules
enclosure Motor starters for use in the control
13/100 - Pushbuttons and indicator lights in the cabinet
enclosure for AS-Interface 8/57 - SIRIUS 3RA6 compact starters:
Masters 3RA61 direct-on-line starters,
3RA62 reversing starters
Masters for SIMATIC ET 200
9/21 Motor starters for use in the field,
2/29 - CM AS-i Master ST for
high degree of protection
SIMATIC ET 200SP
- SIRIUS M200D motor starters for
2/34 - F-CM AS-i Safety ST for
AS-Interface
SIMATIC ET 200SP
D 31.21) SINAMICS G115D distributed converters
Masters for SIMATIC S7
2/37 - CM 1243-2 SIRIUS ACT pushbuttons and indicator
2/39 - CP 343-2P/CP 343-2 lights
13/88 - Modules: AS-Interface modules for
Routers
mounting on the front plate or in the
2/41 DP/AS-Interface Link 20E enclosure
13/100 - Pushbuttons and indicator lights in the
enclosure for AS-Interface
13/170 SIRIUS 8WD42 and 8WD44 signaling
columns
1) See Catalog D 31.2.

Siemens IC 10 · 2023
2
© Siemens 2023

Industrial communication

Power supply units and data Contactors and contactor assemblies


decoupling modules 3/18 - SIRIUS 3RT contactors, 3-pole up to
2/67 AS-Interface power supply units 250 kW
3/142 - SIRIUS 3RA23 reversing contactor
2

2/69 30 V power supply units


assemblies, up to 55 kW
15/11) 24 V power supply units
3/158 - SIRIUS 3RA24 contactor assemblies
2/71 S22.5 data decoupling modules for star-delta (wye-delta) starting,
Data decoupling modules up to 90 kW
for S7-1200 3/101 - SIRIUS 3RA27 function modules
2/73 - DCM 1271 data decoupling module Overload relays
Transmission media 7/127 SIRIUS 3RB24 electronic overload
2/76 AS-Interface shaped cable relays for IO-Link for high-feature
System components and accessories applications
2/77 Repeaters Motor starters for use in the control
cabinet
2/79 Extension plugs
SIRIUS 3RA6 compact starters for
2/80 Addressing units
IO-Link
2/82 Analyzer 8/67 - 3RA64 direct-on-line starters
2/86 Miscellaneous accessories 8/68 - 3RA65 reversing starters
2/12 Diagnostics Monitoring relays
Software 10/55 SIRIUS 3RR24 monitoring relays for
14/19 AS-Interface block library for mounting on 3RT2 contactors for
SIMATIC PCS 7 IO-Link
10/96 SIRIUS 3UG48 monitoring relays
IO-Link
for stand-alone installation for IO-Link
Introduction
10/119 SIRIUS 3RS28 temperature monitoring
2/88 Communications overview relay for IO-Link
2/90 System components SIRIUS ACT pushbuttons and indicator
2/96 IO-Link specification lights
Masters 13/12 SIRIUS ACT 3SU1 ID key-operated
IO-Link master module for S7-1500 switches for IO-Link
2/97 - CM 8xIO-Link 13/89 SIRIUS ACT 3SU1 solid-state modules
IO-Link master module for S7-1200 for IO-Link
SIRIUS 8WD4 signaling columns
2/98 - SM 1278 4xIO-Link master
13/163 Electronically configurable
IO-Link master module for ET 200SP
8WD46 signaling columns,
2/99 - CM 4xIO-Link V1.1 Standard 70 mm diameter NEW NEU

IO-Link master module for ET 200pro 13/170 8WD44 signaling columns,


2/100 - 4 IO-Link HF 70 mm diameter
IO-Link master module for 13/177 - 8WD44 IO-Link adapter element
ET 200eco PN ID 102) RFID systems
2/101 - IO-Link master modules 2/95 IO-Link Device Description (IODD)
IO-Link master module for ET 200AL 2/95 IO-Link Software
2/102 - CM IO-Link 1) See also Catalog KT 10.1.
IO-Link digital modules 2) See Catalog ID 10.
2/103 IO-Link I/O modules

Siemens IC 10 · 2023
© Siemens 2023

Industrial communication
Introduction
AS-Interface

■ Overview
More information
Homepage, see www.siemens.com/as-interface TIA Selection Tool Cloud (TST Cloud), see

2
Industry Mall, see www.siemens.com/product?as-interface www.siemens.com/tstcloud/?node=AsInterface
System Manual for AS-Interface, see
https://support.industry.siemens.com/cs/ww/en/view/26250840

AS-i = simple! AS-i = flexible! AS-i = efficient!


● Only one cable for ● Flexible topologies ● User-friendly
data and energy addressing
● Open standard
● Time-saving ● Fast device
● Expandability
assembly/installation replacement
● Safety engineering
● Engineering in the ● Ruggedness and
TIA Portal stability
● User-friendly ● Device and
maintenance network diagnostics
IC01_00210

AS-Interface AS-i from Siemens has everything in its favor


AS-Interface – the smart communication standard for • Complete AS-i product range for bus-based standard and
universal connection of the field level to the control system safety technology from a single source
The AS-Interface (AS-i) – the Actuator-Sensor-Interface, to be • System-wide integration of the AS-i devices into SIMATIC,
more precise – is a smart bus system for the field level that SINUMERIK and the TIA Portal engineering framework
connects all the sensors and actuators in the field to the higher- • Integration of ASIsafe applications into SIMATIC F controller
level control system more simply, flexibly and efficiently than safety programming
any other. • Central configuration of standard and safety technology in
The structure of a complex automation system is not always the TIA Portal and in STEP 7 (Classic) – just one engineering
clear at first glance. The field level in particular, with its large framework for controller, AS-i master and safety
numbers of devices with real-time requirements, needs a clear • Quick diagnostics of master and slave components via web
structure. browser, HMI or TIA Portal
That is exactly what the AS-i fieldbus delivers: Via a simple • Planning, calculation and verification of the whole safety chain
twisted pair – the yellow AS-i cable – in an AS-i network up based on AS-i Safety with Safety Evaluation in the
to 62 bus nodes can be connected to the AS-i master and TIA Selection Tool, see www.siemens.com/safety-evaluation
simultaneously supplied with power. The standard here is robust • Integration of lower-level AS-i networks into the PCS 7 process
data transmission in a rugged environment with a high degree of control system
protection for the AS-Interface. • Global spare parts logistics, consulting and service

Article No. Page


ASIsafe
ASIsafe enables integration of safety-related components in an AS-Interface network,
for example:
• EMERGENCY STOP pushbuttons
• Protective door switches
• Cable-operated switches
• Other AS-i safety sensors
Your advantage: The simple wiring of AS-Interface is maintained.
AS-i Master and AS-i Safety module for ET 200SP 6ES7 From 2/29
The CM AS-i Master ST and F-CM AS-i Safety ST modules are plugged into an ET 200SP
configuration and connect an AS-i network, including safety-related inputs and outputs,
with the controller.
• Single, double and multiple masters possible
• Per CM AS-i Master ST module up to 496 DI/496 DQ/124 AI/124 AQ possible
• Per F-CM AS-i Safety ST module up to 31 safe input signals (2-channel)/16 safe output
channels possible
• Configuring with TIA Portal or STEP 7 (Classic)
AS-i Master and • Plant-wide safety programming of the F-CPU via SIMATIC Distributed Safety/
AS-i Safety module Safety Advanced/F Systems
• Integrated diagnostics
• No other programming tools required
Your advantage: Modular connection of fail-safe AS-i networks with system-wide
programming in SIMATIC and SINUMERIK controllers.

Siemens IC 10 · 2023 2/3


© Siemens 2023

Industrial communication
Introduction
AS-Interface

Article No. Page


ASIsafe (continued)
AS-Interface safety modules 3RK1 From 2/26
• Complete portfolio of ASIsafe modules
2

• For connection of safety switches with contacts (e.g. position switches)


• Degree of protection IP65/IP67 or IP20
• Especially compact dimensions, with widths from 17.5 mm
K45F
• Up to four safe inputs per module
• Standard outputs are available on the module in addition
• Up to SIL 3/PL e
Your advantage: Easy integration of safe signals both in the switching cabinet and in the field.

SC17.5F
SIRIUS 3SF1 mechanical safety switches for AS-Interface 3SF1 From 12/93
• Plastic with degree of protection IP65 and metal with degree of protection IP66/IP67
• ASIsafe electronics integrated into the enclosure
• Available with separate actuator, with or without tumbler
Your advantage: Conventional wiring of safety functions no longer required.

Safety switch
SIRIUS ACT EMERGENCY STOP mushroom pushbuttons for AS-Interface 3SU14 modules 13/88
• Degree of protection IP66/IP67/IP69 (IP69K) 3SU18 enclosure From 13/100
• Metal or plastic version
• Connection of an EMERGENCY STOP command device according to ISO 13850 to
AS-Interface
EMERGENCY STOP • Safety-related AS-Interface module is snapped onto the command device from behind
mushroom pushbutton • Can be used up to SIL 3/PL e
in enclosure
Your advantage: Easy direct connection of control elements to ASIsafe.

2/4 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
Introduction
AS-Interface

Article No. Page


Masters
The AS-Interface master connects SIMATIC controllers to AS-Interface. It automatically
organizes the data traffic on the AS-Interface cable and handles not only signal processing,

2
but also parameter setting, monitoring and diagnostics functions.
Masters for SIMATIC ET 200
CM AS-i Master ST for SIMATIC ET 200SP 3RK7 From 2/29
• Connection of up to 62 AS-Interface slaves per master
• Connection of up to 496 inputs and 496 outputs per AS-Interface network
• Integrated analog value transmission
• Simple configuration by adopting the ACTUAL configuration on the AS-Interface network
• Easy operation in the input/output address range of the SIMATIC (or other controller)
comparable to standard I/O modules
• Monitoring of the control supply voltage on the AS-Interface shaped cable
CM AS-i Master ST for • Integrated ground-fault monitoring
SIMATIC ET 200SP Your advantage: Easy connection of AS-i networks to distributed I/Os.

F-CM AS-i Safety ST for SIMATIC ET 200SP 3RK7 From 2/34


• Monitoring of up to
- 31 fail-safe AS-i input slaves per F-CM
- 16 fail-safe AS-i outputs per F-CM
• Transmission via PROFIsafe into the F-CPU for safety-related applications up to SIL 3
(IEC 62061)/PL e (ISO 13849-1)
• As a result, these sensors become part of the "unlimited programming and data archiving"
options of SIMATIC and of Safety Integrated.
Your advantage: Easy connection of fail-safe AS-i networks to the distributed I/Os.
F-CM AS-i Safety ST for
SIMATIC ET 200SP
Masters for SIMATIC S7
AS-Interface master connections:
• CM 1243-2 for SIMATIC S7-1200 3RK7 From 2/37
• CP 343-2P, CP 343-2 for SIMATIC S7-300 and ET 200M 6GK7 From 2/39
Features:
• Connection of up to 62 AS-Interface slaves
• Connection of up to 496 inputs and 496 outputs per master or AS-Interface network
• Integrated analog value transmission
CM 1243-2 for • Simple configuration by adopting the ACTUAL configuration on the AS-Interface network
SIMATIC S7-1200
• Easy operation in the input/output address area of the SIMATIC S7 comparable to standard
I/O modules
• Monitoring of the control supply voltage on the AS-Interface shaped cable
Your advantage: Easy connection to SIMATIC controllers.

CP 343-2, CP 343-2P for


SIMATIC S7-300
Routers
• Degree of protection IP20 6GK1 From 2/41
• PROFIBUS slave and AS-Interface master
• Connection of up to 62 AS-Interface slaves per AS-Interface network
• Connection of up to 496 inputs and 496 outputs per AS-i network
• Integrated analog value transmission
• Configuring and uploading of AS-Interface configuration in STEP 7 possible
DP/AS-Interface Link 20E • User-friendly selection of AS-Interface slaves
Your advantage: Compact transition to PROFIBUS
A high-performance router can be set up between PROFINET and AS-Interface by
combining the CM AS-i Master ST and FF-CM AS-i Safety ST modules (for safety-related
applications) in an ET 200SP station, see pages 2/32 and 2/36.

Siemens IC 10 · 2023 2/5


© Siemens 2023

Industrial communication
Introduction
AS-Interface

Article No. Page


Slaves
Slaves contain the AS-Interface electronics and connection options for sensors and actuators
in the field and in the control cabinet. A total of up to 62 slaves can be connected to one bus.
2

The slaves then exchange their data in cyclic mode with a control module (master).
I/O modules for use in the field, high degree of protection
Digital I/O modules, IP67 - K60, K60R, K45 and K20 3RK1, 3RK2 From 2/44
• Degree of protection IP65/IP67 or IP68/IP69 (IP69K)
• Modules available with up to degree of protection IP68/IP69 (IP69K)
• Connection sockets in M8/M12
• Up to eight inputs and four outputs
• A/B technology available
K20 digital module • Contacting protected against polarity reversal
• DIN-rail mounting and wall mounting possible
• Mounting of the module on the base plate using just one screw
• Diagnostics LEDs
Your advantage: Reduction of mounting and startup times by up to 40%.
K45 digital module

K60 digital module


Analog I/O modules, IP67 - K60 3RK1 From 2/54
• Degree of protection IP65/IP67
• Detects or transmits analog signals locally
• 2-/4-channel
• Input modules for up to four current measurement, voltage measurement or
resistance/thermal resistance modules
• Output modules for current or voltage
Your advantage: Easy integration of analog values.
K60 analog module

2/6 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
Introduction
AS-Interface

Article No. Page


Slaves (continued)
I/O modules for use in the control cabinet 3RG9, 3RK1, From 2/57
• Degree of protection IP20 3RK2

2
• No M12 plugs required for connection
• Especially narrow design for SlimLine Compact modules with widths of 17.5 mm
and 22.5 mm
• Analog modules are also available
• Removable, finger-safe terminal blocks that cannot be inadvertently interchanged when
using the SlimLine Compact modules
• Flat design of the flat modules for small control cabinets and confined conditions
SlimLine SlimLine
Compact Compact • Connection with screw terminals or spring-loaded terminals
SC17.5 SC22.5 • DIN-rail mounting and wall mounting possible
• Diagnostics LEDs
Your advantage: Modules enable space-saving use in control cabinets and small local
control boxes.

F90 module

Flat module
Modules with special functions
Counter modules 3RK1 2/64
• Degree of protection IP20
• For evaluation of pulses
• Connection with screw terminals or spring-loaded terminals
Your advantage: Evaluation of pulses which exceed even the clock frequency of AS-Interface.

Counter module
Ground-fault detection modules 3RK1 2/65
• Degree of protection IP20
• Display using LEDs
• Two signaling outputs
Your advantage: Automatic diagnostics of ground faults on AS-Interface.

Ground-fault detection
module
Overvoltage protection modules 3RK1 2/66
• Degree of protection IP67
• Discharge through ground cable with oil-proof outer sheath
• Protection at transition of lightning protection zones
Your advantage: The AS-Interface overvoltage protection module protects downstream
AS-Interface devices or individual sections in AS-Interface networks from conducted
overvoltages.
Overvoltage protection
module

Siemens IC 10 · 2023 2/7


© Siemens 2023

Industrial communication
Introduction
AS-Interface

Article No. Page


Slaves (continued)
Contactors and contactor assemblies
SIRIUS 3RT contactors, 3-pole up to 250 kW 3RT20 From 3/18
2

SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW 3RA23 From 3/142


SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW 3RA24 From 3/158
• Notable reduction of wiring in the control circuit
• Integrated mechanical interlocking
• Prevention of wiring errors in the main circuit

SIRIUS contactor
3RT203.-1NB30-0CC0
SIRIUS 3RA27 function modules 3RA2712 From 3/101
• Connection of 3RT20 power contactors with communication capability, 3RA23 reversing
contactor assemblies, and 3RA24 contactor assemblies for star-delta (wye-delta) starting
to AS-Interface
• Reduction of control current wiring through plug-in design and integrated monitoring of
circuit breaker/motor starter protector and contactor
SIRIUS 3RA2712
• Reduced space requirement in the control cabinet through fewer digital inputs and outputs
function module
in the control system
• Easy configuration through operation of feeders instead of individual contactors
• Enhanced operational reliability and quick wiring thanks to spring-loaded terminals
• Small number of variants through use of identical modules for size S00 to S3 contactors
Your advantage: Shortening of mounting and startup times.
Motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters 3RA6 From 8/57
3RA61 direct-on-line starters, 3RA62 reversing starters 3RA61, 3RA62 From 8/65
• Degree of protection IP20
• Very compact load feeders with the integrated functionality of an electronic overload relay
• As direct-on line or reversing starters for motors up to 15 kW/400 V
• Easy expansion into a communication-capable load feeder using AS-i add-on modules
• On-site safe disconnection also possible using AS-i add-on modules
3RA61 compact starter • Standardized integration of the loads in higher-level control systems using AS-i
Your advantage: Compact solution with minimum wiring outlay for actuating direct-on-line
and reversing starters in the control cabinet.
Motor starters for use in the field, high degree of protection
SIRIUS M200D motor starters for AS-Interface 3RK1 From 9/21
• High degree of protection IP65 for cabinet-free design
• As direct-on line or reversing starters for motors up to 5.5 kW/400 V
• Mechanical or electronic switching for high switching frequencies
• Optional with manual operation and brake actuation
SIRIUS • Expanded diagnostics and parameterization possible through AS-Interface
M200D
motor starter • Easy and consistent integration in STEP 7 through AS-Interface
Your advantage: The correct solution for all simple applications in conveyor systems with
spatially distributed drives.

2/8 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
Introduction
AS-Interface

Article No. Page


Slaves (continued)
SINAMICS G115D distributed inverters SINAMICS Catalog D 31.2
• Robust, with degree of protection IP65/IP66, wide operating temperature range -30 to +55 °C G115D

2
wall-mounted:
• Wide power range from 0.37 to 7.5 kW (SINAMICS G115D motor-mounted up to 4 kW) 6SL352;
• Preconfigured with SIMOGEAR 2KJ8 SINAMICS
• Local commissioning via DIP switch, USB interface and potentiometer or G115D
SINAMICS G120 Smart Access motor-mounted:
SINAMICS G115D 2KJ8
frequency converters, • Integrated safety functions (STO via F-DI or via PROFIsafe)
wall-mounted • Integrated applications for conveyor systems, e.g. for roller conveyor, rotary table,
transfer carriage
• Expanded diagnostics and parameterization through AS-Interface
• Flexible connection method for cables, choice of screw connection or push-in,
compatible with SINAMICS G110D/G110M/G120D
• Optional maintenance switch (SINAMICS G115D wall-mounted)
• Optional manual local operation (SINAMICS G115D wall-mounted)
Your advantage: The simple solution for consistent implementation of distributed plant
concepts with requirements for wall-mounted and motor-mounted variable-speed drives
SINAMICS G115D with Safety functionality.
frequency converters,
motor-mounted
Commanding and signaling devices
SIRIUS ACT pushbuttons and indicator lights for AS-Interface 3SU14 modules 13/88
• AS-Interface modules for snap-on mounting on front plate 3SU18 enclosure From 13/101
• AS-Interface modules for base mounting for mounting in enclosure
• Modular enclosure configuration based on individual specifications
• Enclosures with standard fittings
• Up to six command points for standard signals or EMERGENCY STOP
• Degree of protection IP66/IP67/IP69 (IP69K)
AS-Interface module
• Metal or plastic version
• Indicator lights with integrated LED
• Any change of equipment possible even after installation
Your advantage: Complete operating system with simple AS-Interface integration for
your plant.

AS-i enclosure
SIRIUS 8WD42 and 8WD44 signaling columns 8WD42, 8WD44 From 13/170
• Many optical and acoustic elements can be combined
• Up to four signaling elements can be connected using an AS-Interface adapter element
• With integrated LEDs or with BA15d base for LEDs/incandescent lamps
• For fastening to connection elements (screw or spring-loaded terminals)
• 24 V DC, diameters 50 mm (8WD42) and 70 mm (8WD44)
• Connection with bayonet mechanism
8WD42, AS-Interface Your advantage: Signaling columns for monitoring production sequences and for visual or
8WD44 adapter acoustic warnings in emergency situations, with easy AS-Interface integration.
signaling element
columns

Siemens IC 10 · 2023 2/9


© Siemens 2023

Industrial communication
Introduction
AS-Interface

Article No. Page


Power supply units and data decoupling modules
AS-Interface power supply units generate a controlled direct voltage of 30 V DC with high
stability and low residual ripple in conjunction with data decoupling. They are an integral
2

component of the AS-Interface network and enable the simultaneous transmission of data
and energy on one cable.
In conjunction with data decoupling modules, AS-Interface can also be operated with
standard power supply units.
AS-Interface power supply units 3RX9 2/67
• With wide performance spectrum from 2.6 to 8 A
• Degree of protection IP20
• Separation of data and energy by means of the integrated data decoupling
• UL/CSA approval for global use,
2.6 A version with output power restricted to max. 100 W
(for Class 2 circuits in accordance with NEC)
• Certified for global use
IP20, 3 A
• Integrated ground-fault and overload detection save the need for additional components
and make applications reliable
• Diagnostics memory, remote signaling and Remote RESET allow fast detection of faults
in the system
• Ultra-wide input range permits 1-phase and 2-phase use (8 A version).
Your advantage: Optimum performance for each application.

IP20, 8 A
30 V power supply units
Standard 30 V power supply units without data decoupling 3RX9 From 2/69
• Power spectrum 3 A, 4 A and 8 A
• Overload and short-circuit-proof in every performance class
• Diagnostics: With output voltage > 26.5 V DC
LED and signaling contact for output voltage 30 V O.K.
• Primary-side connection to 120/230 V AC (1-phase) with automatic range selection
PSN130S Your advantage: Economical alternatives in conjunction with data decoupling modules while
30 V DC, 8 A making full use of the maximum AS-Interface cable length.
24 V power supply units
Standard 24 V power supply units (SITOP), without data decoupling 6EP 15/1 or
• Power spectrum 2.5 to 40 A Catalog KT 10.1
• Overload and short-circuit-proof in every performance class
• Add-on modules for signaling, redundancy, buffering and UPS
• 1-, 2- and 3-phase versions
Your advantage: Economical alternatives in conjunction with data decoupling modules.
SITOP PSU100M,
24 V DC, 20 A
S22.5 data decoupling modules 3RK1 From 2/71
• Degree of protection IP20, narrow design 22.5 mm
• Supply of several AS-i networks with a single power supply unit
• Single and double data decoupling
• Operation with 24 V DC or 30 V DC
Your advantage: Cost-effective installation of AS-i networks in conjunction with standard
power supply units.
S22.5 data decoupling
module
DCM 1271 data decoupling module for SIMATIC S7-1200 3RK7 From 2/73
• Simple data decoupling in IP20 design
• Supply of several AS-i networks with a single power supply unit
• Operation with 24 V DC or 30 V DC
Your advantage: Cost-effective installation of AS-i networks in conjunction with standard
power supply units in the design of a SIMATIC S7-1200 module.

DCM 1271 data


decoupling module
Transmission media
AS-Interface shaped cable for connection of network stations
AS-Interface shaped cable 3RX9 2/76
• No polarity reversal thanks to trapezoidal shape
• Cables made of optimized material for different operating conditions
• Special version according to UL CLASS 2 available
Your advantage: Fast replacement and connection to AS-Interface by piercing method.
Shaped cable

2/10 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
Introduction
AS-Interface

Article No. Page


System components and accessories
Accessories comprise tools for mounting, installation and operating as well as individual
components.

2
Repeaters and extension plugs 6GK1 repeater 2/77
• Repeaters for extending the AS-Interface cable by 100 m per repeater 3RK1 extension
• Extension plug for extending the AS-Interface segment to max. 200 m plug 2/79
• Parallel connection of several repeaters possible (star configuration option)
• Maximum size increases (when combined) to more than 600 m
• Easy mounting
Repeater
• IP67 module enclosure
Your advantage: Lower infrastructure costs, more possibilities of use and greater freedom
for plant planning.

Extension Plug Compact


Addressing units 3RK1 From 2/80
• Reading out and adjusting the slave address 0 to 31 or 1A to 31A, 1B to 31B,
with automatic addressing aid and prevention of double addresses
• Reading out the slave profile (IO, ID, ID2) and reading out and setting the ID1 code
• Input/output test when commissioning the slaves, on all digital and analog slaves
according to AS-Interface specification V3.0, including safe input slaves and complex
CTT2 slaves
• Display of the operational current in case of direct connection of an AS-i slave
(measuring range from 0 to 150 mA)
Addressing unit • Storage of complete network configurations (profiles of all slaves) to simplify
for AS-Interface V 3.0 the addressing
Your advantage: Easiest way to address and test the slaves.
AS-Interface analyzer 3RK1 From 2/82
• Diagnostics units for completely checking the quality and function of an AS-Interface
installation
• Transmission of collected data through an RS 232 interface to a PC, evaluation by software
• Easy and user-friendly operation
Analyzer • Automatically generated test logs
• Advanced trigger functions enable exact analysis
• Process data can be monitored online
• In addition to digital I/O data it is possible to view analog values and safety slaves
in data mode.
Your advantage: Preventative testing of an AS-Interface network is possible, recorded logs
facilitate remote diagnostics.
Miscellaneous accessories 3RK1, 3RX9, From 2/86
Individual components such as sealing caps, cable adapters, distributors, 6ES7
M12 plugs and cables, cable end terminator, etc.

M12 sealing cap

Cable end terminator

Siemens IC 10 · 2023 2/11


© Siemens 2023

Industrial communication
Introduction
AS-Interface

Article No. Page


Diagnostics
The following diagnostics blocks with visualization via HMI or web browser for AS-Interface -- --
can be downloaded free of charge in the Industry Online Support Portal:
2

Diagnostics blocks
• For CM AS-i Master ST and F-CM AS-i Safety ST in ET 200SP, see
https://support.industry.siemens.com/cs/ww/en/view/109479103
• For other Siemens AS-i master and links, see
Diagnostics for https://support.industry.siemens.com/cs/ww/en/view/50897766
AS-Interface via
HMI panels Your advantage: Detailed diagnostics display for fast fault analysis and short downtimes –
for easy integration into STEP 7 projects.
Software
AS-Interface block library for SIMATIC PCS 7 3ZS1635 From 14/19
• Engineering and runtime software
• Easy connection of AS-Interface to PCS 7
• Engineering work reduced to positioning and connecting the blocks in the CFC
• No additional configuring steps required for connection to the PCS 7 Maintenance Station,
diagnostics for the AS-i system optimally guaranteed
AS-Interface block library
for PCS 7 Your advantage: Easy connection of AS-Interface to PCS 7, little engineering and
configuration.

Connection methods Ordering notes for multi-unit packaging


SlimLine Compact modules SC17,5, SC17.5F and SC22.5 can
Screw terminals be ordered in practical and environmentally friendly multi-unit
packaging on request.
Spring-loaded terminals,
spring-loaded terminals (push-in) Multi-unit packaging with order code X90
When ordering products in multi-unit packaging, the article
COMBICON connectors (plug-in screw terminals) number of the product concerned must be supplemented with
"-Z" and, in addition, the order code "X90" must be specified.
The terminals are indicated in the corresponding
tables by the symbols shown on orange backgrounds. Ordering examples:
• Safe SlimLine Compact module SC17.5F
3RK1205-0BE00-2AA2-Z X90;
Order quantity 16 items  Packed number of items 16
• Analog SlimLine Compact module SC22.5
3RK1207-0CE00-2AA2-Z X90;
Order quantity 12 items  Packed number of items 12
For more information, see page 16/7.

2/12 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
Introduction
IO-Link

■ Overview
More information
Homepage, see www.siemens.com/io-link For brochure, see

2
TIA Selection Tool Cloud (TST Cloud), see https://assets.new.siemens.com/siemens/assets/api/uuid:ad500ab0-de89-
www.siemens.com/tstcloud/?node=IoLink 4933-8d76-78728f45720d/dffa-b10447-01broschuereiolinkde-144.pdf
For important topics at a glance, see
https://support.industry.siemens.com/cs/ww/en/view/109737170

Engineering and visualization

IO-Link
engineering: Visualization:
SIMATIC SIMATIC HMI
S7-PCT WinCC

Switching cabinet installation Field installation

S7-300/ S7-1200/
S7-400 S7-1500
controller controller

PROFINET

ET 200SP SIMATIC
with IO-Link master ET 200eco PN
IO-Link
with IO-Link
master

SIRIUS SIRIUS IO-Link


3RB24 3RS28 I/O module
SIRIUS overload relay
3RA2 load feeders relay
SIRIUS with 3RA27 SIRIUS
3UG48 function modules 3RT2 contactor
relay with SIRIUS
3RR24 relay

3SU1 ID key-
operated switch

IK10_30141h
RF200 RF200 Standard
8WD44/8WD46 RFID system RFID system sensors
signaling column Actuators

Engineering and visualization


IO-Link – more than just another interface Transparency in the process through IO-Link
IO-Link is an open communication standard for sensors and High system availability and data transparency are market
actuators – defined by the IO-Link Consortium. requirements that must also be met by the connecting of
innovative control technology to a control system. A systematic
IO-Link is a smart concept for the uniform connection of diagnostics concept and efficient handling of parameter data
actuators and sensors to the control level by means of a low-cost are required for this purpose in automation.
point-to-point connection.
With the aid of the IO-Link communication standard,
As an open interface, IO-Link can be integrated into all standard a communication link is established between switchgear and
fieldbus and automation systems. controller, and this allows data to be exchanged efficiently.
The IO-Link communication standard below fieldbus level Based on a standard cable, it is therefore possible to integrate
enables central error diagnostics and localization down parameter, process and diagnostics data and measured values
to actuator/sensor level, and facilitates both startup and into the plant automation with ease. For example, the available
maintenance by allowing parameter data to be dynamically diagnostics data allow potential errors to be detected quickly,
changed directly from the application. thus avoiding lengthy plant downtimes.
The increasing intelligence of field devices and their integration As a consequence of their basic function, such as overload
into automation as a whole now allows data to be accessed right protection (SIRIUS 3RB24 electronic overload relays for
down to the lowest field level. The result: greater plant availability IO-Link), many switchgear units have measured values.
and less engineering work. The availability of these via IO-Link now allows conclusions
to be drawn at an early stage concerning wear and tear in the
application.
At the same time the option of parameterizing via IO-Link
supports the device not just when parameters concerning
operating time are changed, but also when the device is
replaced. In the case of a spare part, for example,
the parameters can be quickly transmitted to a new device
via the communication system.

Siemens IC 10 · 2023 2/13


© Siemens 2023

Industrial communication
Introduction
IO-Link

Article No. Page


Masters
The IO-Link master modules form the heart of the IO-Link system. Catalog ST 70
2

IO-Link master module for SIMATIC S7-1500


CM 8xIO-Link 6ES7 2/97
• Communications module for connecting up to 8 IO-Link devices (three-wire connections)
or 8 standard sensors according to IO-Link specification V1.1
• Can be used directly downstream of an S7-1500 CPU or distributed in ET 200MP via
PROFINET or PROFIBUS
• Simple replacement of sensors/actuators without time-consuming parameterization
• Data transmission rates COM1 (4.8 kBd), COM2 (38.4 kBd), COM3 (230.4 kBd)
Your advantage: Easy connection of IO-Link connections to the SIMATIC S7-1500.

CM 8xIO-Link
for SIMATIC S7-1500
IO-Link master module for SIMATIC S7-1200
SM 1278 4xIO-Link master 6ES7 2/98
• IO-Link master as serial communications module with four ports (channels) according to
IO-Link specification V1.1
• Easy device exchange with automatic data recovery without engineering for IO-Link device
• Up to four IO-Link devices (three-wire connections) can be connected to each IO-Link
master module
• Data transmission rates COM1 (4.8 kBd), COM2 (38.4 kBd), COM3 (230.4 kBd),
automatic adjustment to the data transmission rate supported by the device
Your advantage: Easy connection of IO-Link connections to the SIMATIC S7-1200.
SM 1278 4xIO-Link
for SIMATIC S7-1200
IO-Link master modules for ET 200SP
CM 4xIO-Link V1.1 Standard 6ES7 2/99
• IO-Link master as serial communications module with four ports (channels) according to
IO-Link specification V1.1
• Module replacement with automatic data recovery without engineering for IO-Link master
and device
• Up to four IO-Link devices (three-wire connections) can be connected to each IO-Link
master module.
• Data transmission rates COM1 (4.8 kBd), COM2 (38.4 kBd), COM3 (230.4 kBd),
automatic adjustment to the data transmission rate supported by the device
CM 4xIO-Link Your advantage: Easy connection of IO-Link connections to distributed I/Os.
for ET 200SP
IO-Link master module for ET 200pro
4 IO-LINK HF 6ES7 2/100
• IO-Link master as serial communications module with four ports (channels) according to
IO-Link specification V1.1
• Easy device exchange with automatic data recovery without engineering for IO-Link device
• Up to four IO-Link devices can be connected to each IO-Link master module
• Support of IO-Link Port Class B
• Data transmission rates COM1 (4.8 kBd), COM2 (38.4 kBd), COM3 (230.4 kBd),
automatic adjustment to the data transmission rate supported by the device
Your advantage: Easy connection of sensors and actuators to the I/Os directly in the
IO-Link master module machine's field area.
for ET 200pro
IO-Link master module for ET 200eco PN
IO-Link master 6ES7 2/101
• 4 IO-L + 8 DI + 4 DO 24 V DC/1.3 A
- Up to four IO-Link devices (IO-Link Port Class A) can be connected
- Up to eight standard sensors and up to four standard actuators can be additionally
connected
- Enclosure width 60 mm
• 4 IO-L
- Up to four IO-Link devices (IO-Link Port Class B) can be connected
- Enclosure width 30 mm
6ES7148-6J.00-0.B0 • 8 IO-L + 4 DI 24 V DC
- Up to eight IO-Link devices (4 x Port Class A + 4 x Port Class B) can be connected
- Additionally four digital inputs
- Enclosure width 45 mm
Your advantage: Easy connection of sensors and actuators to the I/Os directly in the
machine's field area.
IO-Link master module for ET 200AL
CM IO-Link 6ES7 2/102
• IO-Link master as serial communications module with four ports (channels) according to
IO-Link specification V1.1
• Easy device exchange with automatic data recovery without engineering for IO-Link device
• Up to four IO-Link devices can be connected to each IO-Link master module
• Support of IO-Link Port Class B
• Data transmission rates COM1 (4.8 kBd), COM2 (38.4 kBd), COM3 (230.4 kBd),
automatic adjustment to the data transmission rate supported by the device
Your advantage: Easy connection of sensors and actuators to the I/Os directly in the
CM IO-Link machine's field area.
for ET 200AL

2/14 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
Introduction
IO-Link

Article No. Page


IO-Link digital modules
IO-Link I/O modules 6ES7 From 2/103
• IO-Link, digital input modules

2
- DI 8 x 24 V DC, 8 x M8
- DI 16 x 24 V DC, 8 x M12
• IO-Link, digital output modules
- DQ 8 x 24 V DC/2 A, 8 x M12
• IO-Link, digital input/output modules
- DIQ 4+DQ 4 x 24 V DC/0.5 A, 8 x M8
- DIQ 16 x 24 V DC/0.5 A, 8 x M12

IO-Link I/O modules


for ET 200AL
Industrial controls
Starters and contactor assemblies for direct-on-line, reversing and star-delta (wye-delta)
starting can be connected to IO-Link through function modules without any additional,
complicated wiring.
Contactors and contactor assemblies
SIRIUS 3RT contactors, 3-pole up to 250 kW 3RT20 From 3/18
SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW 3RA23 From 3/142
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW 3RA24 From 3/158
• Notable reduction of wiring in the control circuit
• Integrated mechanical interlocking
• Prevention of wiring errors in the main circuit

SIRIUS contactor
3RT201.-1B...-0CC0
SIRIUS 3RA27 function modules 3RA2711 From 3/101
• Connection of 3RT20 power contactors with communication capability, 3RA23 reversing
contactor assemblies, and 3RA24 contactor assemblies for star-delta (wye-delta) starting
to IO-Link
• Reduction of control current wiring through plug-in technology, feeder groups and
integrated monitoring of circuit breaker/motor starter protector and contactor
SIRIUS 3RA2711
• Reduced space requirement in the control cabinet through fewer digital inputs and outputs
function module for
in the control system
IO-Link
• Simple user program through operation of feeders instead of individual contactors
• Enhanced operational reliability and quick wiring thanks to spring-loaded terminals
• Can be flexibly combined with many automation solutions using the open, standardized
IO-Link wiring system
• Small number of variants through use of identical modules for size S00 to S3 contactors
Your advantage: Shortening of mounting and startup times
Overload relays
SIRIUS 3RB24 electronic overload relays for IO-Link for high-feature applications 3RB24 From 7/127
• Diagnostics and current value transmission via IO-Link
• Current measuring modules (3RB29) for current values from 0.3 to 630 A
• In connection with contactors: Controlling direct-on-line, reversing and star-delta
(wye-delta) starters via IO-Link
• Full motor protection through PTC connection
Your advantage: Communication-capable overload relay enables remote diagnostics and
preventive maintenance.
SIRIUS 3RB24
overload relay
Motor starters for use in the control cabinet 3RA6 From 8/57
SIRIUS 3RA64, 3RA65 compact starters for IO-Link 3RA64, 3RA65 From 8/67
• Integrated functionality of a circuit breaker, contactor and electronic overload relay and
various functions of optional mountable accessories
• Can be used for direct starting of standard three-phase motors up to 32 A
(approx. 15 kW/400 V)
• Compact design offers enormous savings in space and wiring in the control cabinet
• Low variance of devices thanks to wide setting ranges for the rated current and wide
voltage ranges
SIRIUS 3RA64 Your advantage: The diagnostics data of the process collected by the 3RA6 compact
compact starter starter, e.g. short circuit, end of service life, limit position, etc., are not only indicated on the
compact starter itself but also transmitted to the higher-level control system through IO-Link.

Siemens IC 10 · 2023 2/15


© Siemens 2023

Industrial communication
Introduction
IO-Link

Article No. Page


Industrial controls (continued)
Monitoring relays
SIRIUS 3RR24 monitoring relays for mounting on 3RT2 contactors for IO-Link 3RR24 From 10/55
2

• Monitoring relays for mounting on 3RT2 contactors


• Parameterization and diagnostics via the display on the device or via IO-Link
• Adjustable warning and switch-off limit values and on/tripping delay times
• All current measured values available in the control system
Your advantage: Communication-capable monitoring relay enables remote diagnostics
and preventive maintenance.
SIRIUS 3RR24
monitoring relay
SIRIUS 3UG48 monitoring relays for stand-alone installation for IO-Link 3UG48 From 10/96
• Monitoring of
- Network (3UG481)
- Voltage (3UG483)
- Current (3UG4822)
- Power factor and active current (3UG484)
- Fault current (3UG4825)
- Speed (3UG485)
• Parameterization and diagnostics via the display on the device or via IO-Link
SIRIUS 3UG48
monitoring relay • Adjustable warning and switch-off limit values and on/tripping delay times
• All current measured values available in the control system
Your advantage: Communication-capable monitoring relay enables remote diagnostics
and preventive maintenance.
SIRIUS 3RS28 temperature monitoring relay for IO-Link 3RS28 From 10/119
• Measuring the temperature of solids, liquids and gases
• Use of resistance sensors or thermocouples
• Parameterization and diagnostics via the display on the device or via IO-Link
• Adjustable warning and switch-off limit values and on/tripping delay times
• All current measured values available in the control system
Your advantage: Independent monitoring easily linked to the control system.
SIRIUS 3RS28
temperature monitoring relay
SIRIUS ACT pushbuttons and indicator lights
SIRIUS ACT 3SU1 ID key-operated switches for IO-Link 3SU1 13/12
• Access system and selection system for four authorization levels
• Authentication of groups and persons
• Five ID keys with different coding
SIRIUS ACT • Option for individual coding via IO-Link
3SU1 ID • For installation in enclosures or fastening on front plate
key-operated switch
• Solid-state module for ID key-operated switches must be ordered separately.
Your advantage: Only authorized personnel can work on plants and machines.
SIRIUS ACT 3SU1 solid-state modules for IO-Link 3SU1400 13/89
• Eight digital inputs and outputs possible
• DI and DQ freely selectable (programmable)
• Input and output functions parameterizable
• Connection method (push-in)
• For installation in enclosures or fastening on front plate
SIRIUS ACT
3SU1 solid-state module Your advantage: No wiring required if ordered in a 3SU1 enclosure via configurator.

2/16 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
Introduction
IO-Link

Article No. Page


Industrial controls (continued)
SIRIUS 8WD4 signaling columns
Electronically configurable 8WD46 signaling columns, 70 mm diameter 8WD46 From 13/163

2
Signaling columns for IO-Link, with or without audible signal
• Configuration of signaling column via IO-Link interface (IODD)
• Fast connection of signaling columns to application using 4-pole M12 plugs
• Via the IO-Link interface, the pattern, color and brightness of the individual segments
(9 to 15 segments) can be set.
• The audible signal can also be set (volume, type of sound up to 105 dB).
Your advantage: Signaling columns for monitoring production sequences and for visual or
acoustic warnings in emergency situations, with easy IO-Link connection.

8WD46 signaling column


8WD44 signaling columns, 70 mm diameter 8WD44 From 13/170
• Up to five signaling elements can be connected using an IO-Link adapter element
• 24 V DC
• Connection with bayonet mechanism
• For fastening on feet
• Connection elements with screw or spring-loaded terminals or connection element with
5-pole M12 plug
Your advantage: Signaling columns for monitoring production sequences and for visual or
8WD44 8WD44 acoustic warnings in emergency situations, with easy IO-Link connection.
signaling IO-Link
column adapter
element
IO-Link RFID systems
SIMATIC RF200 RFID system in the HF range 6GT2 Catalog ID 10
Products SIMATIC RF210R, SIMATIC RF220R, SIMATIC RF240R,
SIMATIC RF250R, SIMATIC RF260R
• Simple identification tasks such as reading an ID number (UID)
• Reading of user data
• Writing of user data
• No RFID-specific programming, ideal for those new to RFID
RFID system for IO-Link • Simple connection via master modules for IO-Link, such as SIMATIC S7-1200, ET 200SP,
ET 200pro, ET 200eco PN and ET 200AL
• Use with the tried and tested ISO 15693 transponders (MDS Dxxx)
IO-Link Device Description (IODD)
IODD files -- 2/95
These files provide the device description for IO-Link devices.
• Comprehensive IODD catalog of SIEMENS IO-Link devices
• Freely available for download from Industry Online Support, see
https://support.industry.siemens.com/cs/ww/en/ps/15851

IODD files for IO-Link


IODDfinder -- 2/95
The entire world of IO-Link under one roof
The IODDfinder is a service provided by the IO-Link community. It is a central cross-vendor
database for descriptive files (IODDs). In addition, the platform provides an overview of
IODDfinder for IO-Link the available IO-Link devices.
For more information, see https://ioddfinder.io-link.com/#/.

Siemens IC 10 · 2023 2/17


© Siemens 2023

Industrial communication
Introduction
IO-Link

Article No. Page


IO-Link software
S7-PCT (Port Configuration Tool) -- 2/95
Engineering software for configuring the IO-Link master modules for SIMATIC S7-1200,
2

ET 200MP, ET 200SP, ET 200pro, ET 200eco PN and ET 200AL


• Available as a stand-alone version or integrated into STEP 7 (V5.5 SP1 and higher)
and TIA (V12 and higher)
• Engineering of the IO-Link devices connected to the master
S7-PCT
• Monitoring of the process image of the IO-Link devices
• Open interface for importing further IODDs
• Freely available for download from Industry Online Support, see
https://support.industry.siemens.com/cs/ww/en/view/32469496
Library for IO-Link (LIOLink) -- 2/95
This library provides blocks and PLC data types to enable easy communication between
the SIMATIC controller and the IO-Link master or IO-Link device.
• Freely available for download from Industry Online Support, see
https://support.industry.siemens.com/cs/ww/en/view/82981502

Library for IO-Link


(LIOLink)
WFB50001 Application of the device-specific blocks for IO-Link -- 2/95
"IO_LINK_DEVICE"
EN END This application illustrates in a specific example how easy it is to connect Siemens IO-Link
REQ DONE_VALID
ID BUSY
devices to a SIMATIC S7 CPU using the library for IO-Link (LIOLink).
CAP ERROR
RD_WR STATUS • Freely available for download from Industry Online Support, see
PORT
IOL_INDEX
IOL_STATUS
RD_LEN
https://support.industry.siemens.com/cs/ww/en/ps/90529409
IOL_SUBINDEX
LEN
IC01_00467

RECORD_IOL_
DATA

Function block
IO-Link device

2/18 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
Introduction
Communications overview

■ Overview
AS-Interface is an open, international standard according to
IEC 62026-2 for process and field communication. Leading
manufacturers of actuators and sensors all over the world

2
support the AS-Interface. Interested companies are provided
with the electrical and mechanical specifications by the
AS-Interface Association. Video: AS-Interface – Powerful integration in SIMATIC ET 200SP
AS-Interface is a single master system. For automation systems
from Siemens, there are communications processors (CPs),
communications modules (CMs) and routers (links) that control
the process or field communication as masters, and actuators
and sensors that are activated as AS-Interface slaves.
More information
Homepage, see www.siemens.com/as-interface TIA Selection Tool Cloud (TST Cloud), see
Industry Mall, see www.siemens.com/product?as-interface www.siemens.com/tstcloud/?node=AsInterface

Remote access, Telecontrol stations (RTUs)


Laptop e.g. via teleservice
ET 200SP
S7-1500 RTU RTU S7-1200
RTU
PC

OpenVPN
RTU3030C

Controller Numeric control


Control and SINEMA Motion control
monitoring system Telecontrol Remote SINEMA PC/PG/IPC Controller
and systems Database Remote
Connect server Connect
substation
control server

Firewall

PROFINET
Industrial Ethernet

Access Access
Controller point point
Controller PC/PG IWLAN
Notebook RCoax cable Industrial Ethernet
switches

Controller
Control and PC/PG/IPC
Field device for monitoring system Wireless
intrinsically safe area Remote devices
maintenance
access SCALANCE
Numeric SC646-2C
Coupler control
Link

PROFIBUS PA PROFIBUS
ASM456 Field devices

Mobile Optical
Field devices reading
Mobile HMI
SIMOCODE RF185C systems
HMI
pro IO-Link RFID system Access
RFID Optical master
reading IO-Link point
system DP slave Motion control
IO-Link systems systems
IO-Link
AS-i master I/O module AS-i master
IO-Link DP/AS-i Link 20E in ET 200SP in ET 200SP
I/O module AS-Interface
power supply Protection and
Slave monitoring Client
devices module
SINAMICS
drives RFID Compact
Compact Signaling column Protection and RFID system feeder
feeder monitoring system
G_IK10_XX_20002e
devices
AS-Interface
Compact
feeder Field device

Slave Slave
Slave Slave
AS-Interface
Compact Signaling column power supply
feeder

AS-Interface in the SIMATIC NET communications landscape

Siemens IC 10 · 2023 2/19


© Siemens 2023

Industrial communication
AS-Interface
Introduction
Communications overview

■ Benefits
An important characteristic of the AS-Interface technology Elaborately wired control cables in the control cabinet and
is the use of a shared twisted pair for data transmission and marshaling racks can be replaced by AS-Interface.
distribution of auxiliary power to the sensors and actuators.
2

An AS-i power supply unit or alternatively a standard power The AS-Interface cable can be connected to any points thanks
supply unit that meets the requirements of the AS-Interface to a specially developed cable and connection by the insulation
transmission method and has an external AS-i data piercing method.
decoupling module is used for the distribution of auxiliary power. With this concept you become extremely flexible and achieve
The AS-Interface cable used for the wiring is mechanically high savings.
coded and hence protected against polarity reversal and can
be easily contacted by the insulation piercing method.

■ Application
I/O data exchange Command interface
The AS-i master automatically transfers the inputs and outputs In addition to I/O data exchange with binary and analog
between the controller and the digital and analog AS-Interface AS-Interface slaves, the AS-Interface masters can provide
slaves. Slave diagnostics information is forwarded to the control a number of other functions through the command interface.
system when required.
Hence it is possible, for example, for slave addresses to
The latest AS-Interface masters according to the AS-Interface be issued, parameter values transferred or configuration
specification V3.0 support integrated analog value processing. information read out from user programs.
This means that data exchange with analog AS-Interface slaves
is just as easy as with digital slaves. For more information, see
https://support.industry.siemens.com/cs/ww/en/view/51678777.

2/20 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
Introduction
System components

■ Overview
To implement communication, the following components of • Network components such as repeaters and extension plugs
a system installation are available: (cannot be used for AS-i Power24V)

2
• AS-i master modules for central control units such as • I/O modules (AS-i slaves) for connection of standard
SIMATIC S7, ET 200M/ET 200SP distributed I/Os, or network sensors/actuators
transitions from PROFIBUS to AS-Interface • Actuators and sensors with integrated AS-i slave
• AS-i power supply unit or alternatively a standard power • Safe I/O modules (ASIsafe slaves) for transmitting
supply unit in combination with an AS-i data decoupling safety-related data through AS-Interface
module for the power supply to the slaves and sensors
• Addressing device for setting slave addresses during
• AS-Interface shaped cables commissioning

SIMATIC/
SIMOTION SINUMERIK

IK10_20027q
PROFINET

Industrial Ethernet
CM AS-i Master ST and CM AS-i Master ST and PROFIBUS DP
F-CM AS-i Safety ST F-CM AS-i Safety ST
for SIMATIC ET 200SP for SIMATIC ET 200SP
S7-300 CP 343-2(P)
AS-Interface S7-300 CP 343-2(P)
power supply
AS-Interface
DP/AS-i Link 20E power supply
S7-1200 with CM 1243-2
S7-1200 with CM 1243-2
AS-Interface AS-Interface

Digital and analog Safety switch Signaling Pushbuttons Safe and


K20, K45, K60 field modules column Indicator lights standard control
without with Safe Safety Safe and
tumbler tumbler field cabinet modules
switch standard control
module cabinet modules
EMERGENCY EMERGENCY
STOP STOP

3RA2 load SIRIUS 3RA2 load SIRIUS


feeder with M200D feeder with M200D
3RA27 function motor 3RA27 function motor
module starters module starters

24 V DC 24 V DC
power supply power supply

SINAMICS G115D SINAMICS G115D


frequency converters frequency converters

Example of a configuration with the system components


Features
Standard IEC 62026-2 Maximum cycle time • 5 ms in maximum configuration with 31 standard
Topology Line, star or tree structure addresses
(same as electrical wiring) • 10 ms in maximum configuration with 62 A/B
addresses
Transmission medium Unshielded twisted pair (2 x 1.5 mm2) • Profile-specific for slaves with extended data,
for data and auxiliary power e.g. analog slaves
Connection methods Contacting of the AS-Interface cable by insulation Number of stations • Up to 62 slaves (A/B addressing)
piercing method per AS-Interface line • Integrated analog value transmission
Maximum cable length • 100 m without repeater, without an extension plug Number of binary Max. 496 DI/496 DQ
• 200 m with an extension plug sensors and actuators
• 300 m with two repeaters in series connection
• 600 m with three extension plugs and two Access control • Cyclic polling master/slave procedure
repeaters connected in parallel • Cyclic data acceptance from host (PLC, PC)
Longer cable lengths also possible through Error safeguard Identification and repetition of faulty message
parallel connection of more repeaters. frames

Siemens IC 10 · 2023 2/21


© Siemens 2023

Industrial communication
AS-Interface
Introduction
AS-Interface specification > Specification V3.0

■ Overview
Scope of AS-Interface specification V3.0
More information
Maximum number Number of digital Number of digital
2

System Manual for AS-Interface, see


of slaves inputs outputs
https://support.industry.siemens.com/cs/ww/en/view/26250840
Digital Analog ASIsafe DI DQ
62 62 31 62 x 8 = 496 62 x 8 = 496 AS-Interface product range
Basic data AS-Interface products from Siemens use the current
• AS-Interface specification 3.0 describes a fieldbus system AS-Interface specification V3.0, which is standardized
with an AS-i master and up to 62 AS-i slaves. internationally as IEC 62026-2.
• Every AS-i slave with standard addressing occupies one The alternating pulse modulation developed more than 20 years
AS-i address (1...31). ago for AS-Interface has proven to be a reliable transmission
• Slaves with extended addressing divide an AS-i address into method with which the direct voltage supply for the bus modules
an A address (1A...31A) and a B-address (1B...31B). Up to and the connected sensors is provided on the standard
62 A/B slaves can be connected accordingly to one twisted pair.
AS-Interface network.
• Mixed operation of slaves with standard addressing and Multiple development stages were implemented to produce
extended addressing (A/B slaves) is possible without the proven-in-use system components with optimum EMC
difficulty. The AS-i master identifies automatically which type properties available today. The extensive product range with
of slave is connected, so no special adjustments are required AS-Interface specification V3.0 undergoes constant innovation
of the user. and is extremely cost-efficient, both to install and operate.
• One digital AS-i slave typically has up to four digital inputs and
The bus cable can be retrofitted with repeaters of AS-Interface
four digital outputs.
specification V3.0, and the modules function without any
• Transmission of the digital input/output data requires max.
reciprocal interference. Master modules from Siemens enable
5 ms cycle time for 31 slaves; for further values, see
ideal integration into the SIMATIC environment, in particular for
"Communication cycle".
the AS-Interface master of the ET 200SP distributed I/O system.
• Integrated analog value transmission permits access to both
analog values and digital values without the need for any The underlying industrial requirements for the system concept
special function blocks. are still applicable today: Numerous individual digital input and
output signals are spatially distributed in the machine. Rather
Communication cycle than having to install thick cable harnesses from the control
Maximum cycle time (digital signals) cabinet to the sensors and actuators, smaller, more manageable
AS-i modules are simply inserted in situ onto the bus cable in the
• 5 ms with 31 slaves
• 10 ms with 62 slaves IP67 enclosure, and the sensors and actuators connected with
• Up to 20 ms for slaves with A/B address and 4 DI/4 DQ short M12 cables.
• Up to 40 ms for slaves with A/B address and 8 DI/8 DQ
An additional AS-i module is installed in proximity to the next
Each address is queried in max. 5 ms cycle time. If two A/B sensor to ensure that the length of the M12 cables is kept as
slaves are operated on one basic address (e.g. 12A and 12B), short as possible. As analog signals are likewise transmitted
a maximum of 10 ms will be required to update the data of without any problems, the AS-Interface also replaces the long,
both slaves. shielded analog cables.
Slaves with A/B addressing transmit max. 4 DI/3 DQ in one cycle. Depending on requirements, the switching devices can also
be connected to AS-i modules with terminal connection or
Slaves with A/B addressing and 4 DQ or 4 DI/4 DQ transmit the conveniently used with the integrated AS-i connection. Motor
output data in two consecutive cycles. The double transmission controllers with digital and analog inputs and outputs are also
time of these outputs has no effect in typical applications. offered with the current AS-Interface specification V3.0.
The transmission procedure is performed automatically by the
AS-i master in accordance with AS-i specification V3.0. These Safety signals are also transmitted simply and flexibly by the
slaves are identified in the selection data with addressing AS-Interface. The safety-related sensors for protective doors
type A/B (spec. V3.0). and EMERGENCY STOP buttons can be installed and retrofitted
in any position.
Slaves with a single A/B address and 8 DI/8 DQ transmit
the input and output data in four consecutive cycles. The AS-i Safety functionality from Siemens has been
The transmission time of the inputs/outputs of these slaves continuously optimized and complies with the proven
increases accordingly. The transmission procedure is AS-Interface specification V3.0.
performed automatically by the AS-i master in accordance
with AS-i specification V3.0. For industrial components which require greater transmission
capacities, Siemens provide respective solutions with the
The slaves offered by Siemens with 8 DI or 8 DI/2 DQ use two suitable communications systems.
AS-i addresses so that the time-consuming procedure is not
needed and a fast data update is ensured. The AS-Interface system from Siemens continues to provide an
ideal and consistent solution for a multitude of simple sensors
All slave types can be mixed and used on a single AS-Interface and actuators, including safety technology and special
network. applications.
For more information, such as the addressing type used by the Available masters with the latest AS-Interface specification V3.0
AS-interface slave (standard or A/B address), see the "Selection • CM AS-i Master ST, F-CM AS-i Safety ST (ET 200SP)
and ordering data" for the relevant slave.
• CM 1243-2 (S7-1200)
• CP 343-2P/CP 343-2 (S7-300/ET 200M)
• DP/AS-Interface Link 20E

2/22 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
Introduction
AS-Interface specification > AS-i Power24V

■ Overview Requirements for operation of an AS-i Power24V network


• When 24 V power supply units are used, the maximum
More information network range of 50 m must be observed to reach slaves and
sensors with a sufficient level of voltage (at least 18 V).
For a complete overview of AS-i Power24V-capable devices currently

2
available from Siemens, see • The power supply units must comply with the ES1
https://support.industry.siemens.com/cs/ww/en/view/42806066 (IEC 62368-1) or PELV (Protective Extra Low Voltage)/
For details of AS-i Power24V, see System Manual for AS-Interface, SELV (Safety Extra Low Voltage) standards, have a residual
https://support.industry.siemens.com/cs/ww/en/view/26250840 ripple of < 250 mVpp, and must limit the output voltage to
a maximum of 40 V in the event of a fault. We recommend
SITOP power supplies, see page 15/1 or Catalog KT 10.1,
https://support.industry.siemens.com/cs/ww/en/view/109745655.
• When used in conjunction with standard 24 V power supply
units, each AS-Interface network requires AS-i Power24V-
capable data decoupling, see page 2/71 onwards.
• For reliable operation of an AS-i network with 24 V voltage,
it is important that the masters, slaves and other components
are approved for AS-i Power24V. AS-i Power24V-capable
AS-i components can also be used without restriction in
standard 30 V AS-i networks.
• Use of repeaters or extension plugs in AS-i Power24V
networks is not permitted.

■ Benefits
In small control cabinets the AS-i power supply unit can be
replaced by an AS-i data decoupling module that is connected
to an existing 24 V power supply unit.
AS-Interface data decoupling modules for AS-i Power24V • The advantages of the AS-i communications system in terms
Left: S22.5 data decoupling module,
Right: DCM 1271 data decoupling module for SIMATIC S7-1200 of commissioning, maintenance and diagnostics can be fully
exploited.
Parallel wiring frequently dominates, above all, in applications • If a double data decoupling module is used, two AS-i networks
with very few I/Os. AS-Interface can, however, also replace can be supplied.
extensive parallel wiring in small applications at a favorable price.
AS-i Power24V enables an already existing standard 24 V DC ■ Application
power supply unit to be used for the AS-i network.
Configuration of an AS-i Power24V network
Data and power in the standard AS-Interface network
One of the great advantages of AS-Interface is the ability
to convey not only data, but also the power needed for the PROFINET
connected slaves and sensors over the same unshielded
twisted pair. This is owed to the service-proven AS-Interface S7-1200 with DCM 1271, CM 1243-2
power supply units which provide integrated data decoupling and 24 V standard power supply unit
as well as overload and short-circuit protection and integrated
ground-fault monitoring.
AS-i Power24V
Up to 50 m
Instead of the AS-Interface power supply unit (with 30 V output
voltage and integrated data decoupling) the AS-i cable is
supplied via a data decoupling module from a 24 V standard AS-Interface
power supply unit. The communication technology of
AS-Interface works at the same high level of quality with
NSB0_02245a

an operational voltage of both 30 V DC and 24 V DC.


I/O modules
Key data of AS-i Power24V
Number of Up to 62 slaves and up to 31 safe slaves
slaves
Configuration of an AS-i Power24V network with an AS-Interface
Topology Any DCM 1271 data decoupling module and S7-1200 (simple network)
Range Up to 50 m
Components • 24 V power supply unit with low residual ripple and
limitation to max. 40 V
• AS-i Power24V-capable data decoupling with integrated
ground-fault detection
• AS-i Power24V-capable masters, slaves and components

Siemens IC 10 · 2023 2/23


© Siemens 2023

Industrial communication
AS-Interface
ASIsafe
Introduction

■ Overview
Higher-level control
More information
As usual, nodes on the AS-Interface bus are controlled in
For more information and typical circuit diagrams on safety engineering, see operation by the standard program of the higher-level
2

https://support.industry.siemens.com/cs/ww/en/view/83150405
SIMATIC (F) CPU or by a SINUMERIK control.
ASIsafe – Safety is included Configuring safety functions
ASIsafe enables the integration of safety-related components In order to implement safe functions, the information from the
such as EMERGENCY STOP pushbuttons, protective door safe and standard nodes must be combined logically and
switches, cable-operated switches or other AS-i safety sensors further parameters set.
in an AS-Interface network. These are fully compatible with the
familiar AS-Interface components (masters, slaves, power In conjunction with the modular safety AS-i master,
supply units, repeaters, etc.) in accordance with IEC 62026-2 which is formed by combining the CM AS-i Master ST and
and are operated in conjunction with them on the yellow F-CM AS-i Safety ST modules in an ET 200SP station, all safety
AS-Interface cable. functions and combinations are configured via STEP 7 and
processed in the controller (F-CPU) by the Failsafe program.
Tested safety
• Protective door switches
• Cable-operated switches
• Other AS-i safety sensors
The transmission method for safety-related signals is released
for applications up to SIL 3 (IEC 62061)/PL e (ISO 13849-1).

■ Benefits
• Simple system structure thanks to standardized AS-Interface • Inclusion of the safety signals in the plant diagnostics,
technology also on existing HMI Panels
• Safety-related and standard data on the same bus • Approved up to SIL 3 (IEC 62061)/PL e (ISO 13849-1)
• Existing systems can be expanded quickly and easily • ASIsafe is certified by TÜV (Germany), NRTL (USA)
• Optimum integration in TIA (Safety Diagnostics) and INRS (France)
and Safety Integrated

■ Application
Integrated safety technology in the AS-Interface system can be
used wherever EMERGENCY STOP buttons, protective door
interlocks, safety switches, light arrays and two-hand operation
are installed.

2/24 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
ASIsafe
AS-i safety solution with F-CPU and AS-i in ET 200SP

■ Overview
Operational Safety-oriented

2
control processing

Safe control
e.g. SIMATIC S7-1500F
or SIMATIC S7-300F/S7-400F
PROFINET/PROFIsafe or SINUMERIK 840D sl

ET 200SP with ET 200SP with


CM AS-i Master ST and CM AS-i Master ST and
F-CM AS-i Safety ST F-CM AS-i Safety ST
AS-Interface AS-Interface AS-Interface
power supply power supply power supply
AS-Interface/ AS-Interface/ AS-Interface/
ASIsafe ASIsafe ASIsafe

IC01_00288f
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6

1 Safe EMERGENCY STOP 4 Signal column


2 Safety switch with tumbler 5 Digital K45 field module
3 Field module 6 3RA2 load feeder

AS-Interface configuration with AS-i master modules in the ET 200SP


The AS-i communications modules in the ET 200SP
facilitate the use of AS-Interface under fail-safe SIMATIC
or SINUMERIK controllers.
The allocation of tasks is as follows:
• Acquisition of safety-related signals via safe input slaves on
the AS-Interface bus.
Further signals can be detected through other F-DI modules
of the SIMATIC.
• Evaluation and processing of signals via the fail-safe SIMATIC
or SINUMERIK control
• Reacting by means of safety output modules on the
AS-Interface bus
or other SIMATIC F-DQ modules
Simple combination of the CM AS-i Master ST and
F-CM AS-i Safety ST modules in one ET 200SP station results in
a powerful, safety-related network transition between PROFINET
(or PROFIBUS) and AS-Interface, which can be expanded
further in a modular fashion with further I/O modules of the
ET 200SP.
Using these design methods, it is possible to create
configurations for virtually any application. Besides the single
AS-i master, double, triple or generally multiple masters can be
realized with or without Failsafe functionality.
F-CM AS-i Safety ST for SIMATIC ET 200SP, see page 2/34
onwards.

Siemens IC 10 · 2023 2/25


© Siemens 2023

Industrial communication
AS-Interface
ASIsafe
AS-Interface safety modules

■ Overview
AS-Interface safety modules
The following modules are available for selection:
2

K20F compact safety modules for use in the field


Being only 20 mm wide, the K20F module is particularly well
suited for applications where modules need to be arranged in
the most confined space. The K20F modules are connected to
the AS-Interface with a round cable with M12 cable box instead
of with the AS-Interface flat cable. This enables extremely
compact installation. The flexibility of the round cable means
that it can also be used on moving machine parts without any
problems. The K20 modules are also ideal for such applications
as their non-encapsulated design makes them particularly light
in weight.
K45F compact safety modules for use in the field
The platform of the K45F modules covers the connection of
("mechanical") switches/safety sensors with contacts:
AS-Interface safety modules: K45F (left), K20F (center) and • K45F 2 F-DI: two safety-related inputs. These can be used in
SC17.5F (right) a 2 x 1-channel configuration for applications up to SIL 1/PL c
or as 1 x 2-channel for applications up to SIL 3/PL e
Safety modules for AS-Interface (ASIsafe modules) are available according to IEC 62061 or ISO 13849.
for field use in degree of protection IP67 (K20F and K45F
compact modules) and for the control cabinet (SC17.5F • K45F 2 F-DI/2 DQ: There are also two standard outputs
SlimLine Compact modules) in degree of protection IP20. in addition to the safe inputs. Depending on the selected
K45F module, the outputs are powered either from the yellow
A very compact module with an optimum price/performance AS-Interface cable or via the auxiliary voltage Uaux from the
ratio is thus available for every application. black 24 V DC cable. Modules with degree of protection IP67
All modules for the connection of (mechanical) switches and do not have a switch for setting the power supply on the
safety sensors with contacts feature cross-circuit monitoring of module.
the connected sensor line. • K45F 4 F-DI: four safety-related inputs. Functionality as for two
K45F 2 F-DI modules, but combined with a K45F enclosure.
Function Extremely compact double slave (uses two AS-i addresses)
The safety-related modules with 2 F-DI have two safe inputs. • K45F 4 F-DI: These can be used in a 2 x 1-channel
These inputs can be used in a 2 x 1-channel configuration for configuration for applications up to SIL 1/PL c or as
applications up to SIL 1/PL c or as 1 x 2-channel for applications 1 x 2-channel for applications up to SIL 3/PL e according
up to SIL 3/PL e according to IEC 62061 or ISO 13849. to IEC 62061 or ISO 13849. Extremely compact double slave
According to the AS-Interface specification, the two safe inputs (uses two standard AS-i addresses)
are always evaluated in AND-gated pairs, i.e. the two inputs
always influence the safety function as a pair and cannot SC17.5F SlimLine Compact safety modules with a width of just
therefore influence the two different actuators independently. 17.5 mm for use in control cabinets and local control boxes
A safety-related module takes up one AS-i address (1 ... 31) With a width of only 17.5 mm, the safe SC17.5F SlimLine
with standard addressing and no A/B address. Compact modules are ideal for space-saving use in a control
If the module is used in a 2 x 1-channel configuration, cabinet. The modules have two safety inputs for connecting
the actuator can be activated as soon as the contacts are signals to ASIsafe networks in the control cabinet. In operation
closed at both inputs. No discrepancy check is made. up to SIL 1/PL c, the two inputs can be assigned separately (with
AND gating of the inputs); if SIL 3/PL e is required, the inputs
If the module is used in a 1 x 2-channel configuration, must be used in a 2-channel configuration.
the actuator can be activated as soon as the contacts are closed
at both inputs and no discrepancy has first been detected at the There are also two module variants which have two standard
input pair. The response of the discrepancy check can be outputs in addition to the two safety inputs. The outputs are
checked via the evaluation unit (e.g. F-CM AS-i Safety module). supplied either from the yellow AS-Interface cable alone, or via
auxiliary voltage from the black 24 V DC cable. The supply
The safety-related modules with 4 F-DI have four safe inputs, voltage is set via a slide switch on the rear of the device.
where each pair of 2 F-DI exert an influence jointly as described
above (2 x 2 F-DI). The two input pairs work independently of When using several modules, they can be connected simply
each other. Each input pair can influence on one actuator via the optional device connector. This simplifies the wiring.
(i.e. a safety function). The safety-related modules with The yellow AS-i bus cable and the 24 V DC auxiliary voltage
4 F-DI take up two AS-i addresses. Uaux then only need to be connected to one module.

Safety-related modules with 2 F-DI/2 DQ contain not only the


safety-related inputs but also non-safety-related standard
outputs. The standard outputs must not be used for safety-
related switching functions.
The safe inputs are designed for connecting (mechanical)
switches. Safety sensors with solid-state outputs (OSSD)
cannot be used at the safe inputs.

2/26 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
ASIsafe
AS-Interface safety modules

■ Selection and ordering data


For multi-unit Version Article No. Price PU PS* PG
packaging for SC17.5F, per PU (UNIT,
see page 16/7. SET, M)

2
K20F compact safety modules
Slave addressing type: Standard address
I/O type Uaux 24 V
2 F-DI -- 3RK1205-0BQ30-0AA3 1 1 unit 42C

3RK1205-0BQ30-0AA3
K45F compact safety modules
Slave addressing type: Standard address
(modules supplied without mounting plate)
I/O type Uaux 24 V
2 F-DI -- 3RK1205-0BQ00-0AA3 1 1 unit 42C
4 F-DI1) -- 3RK1205-0CQ00-0AA3 1 1 unit 42C
3RK1205-0BQ00-0AA3 2 F-DI/2 DQ -- 3RK1405-0BQ20-0AA3 1 1 unit 42C
2 F-DI/2 DQ  3RK1405-1BQ20-0AA3 1 1 unit 42C
SC17.5F SlimLine Compact safety modules
Slave addressing type: Standard address
I/O type Outputs
Screw terminals

2 F-DI -- 3RK1205-0BE00-2AA2 1 1 unit 42C


Spring-loaded terminals
3RK1405-2BE00-2AA2 (push-in)
2 F-DI -- 3RK1205-0BG00-2AA2 1 1 unit 42C
Screw terminals

2 F-DI/2 DQ UASI/Uaux supply selectable 3RK1405-2BE00-2AA2 1 1 unit 42C


Spring-loaded terminals
(push-in)
2 F-DI/2 DQ UASI/Uaux supply selectable 3RK1405-2BG00-2AA2 1 1 unit 42C
✓ Available or possible The existing SlimLine series of ASIsafe modules for use in the
-- Not available or not possible control cabinet and local control boxes is being replaced by the
1)
Module occupies two AS-Interface addresses new SlimLine Compact series. We recommend that these new
devices are used in future.
For the conversion table, see page 2/61.
Standard I/O modules for AS-Interface
Note:
• For degree of protection IP67, see page 2/44 onwards
• For degree of protection IP20, see page 2/59 onwards The previous SlimLine devices are still available for use as
replacements in existing systems. As a result of the innovation,
the new SlimLine Compact devices are not fully compatible in
terms of either mechanical dimensions or electrical properties.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/27
© Siemens 2023

Industrial communication
AS-Interface
ASIsafe
AS-Interface safety modules

■ Accessories
More information
For the Equipment Manual for SlimLine Compact modules, see
2

https://support.industry.siemens.com/cs/ww/en/view/109481489

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Accessories for compact safety modules


K45 mounting plates
For mounting K45F
• For wall mounting 3RK1901-2EA00 1 1 unit 42C
• For DIN-rail mounting 3RK1901-2DA00 1 1 unit 42C

3RK1901-2EA00
Input bridges for K45F
• Black version 3RK1901-1AA00 1 1 unit 42C
3RK1901-1AA00 • Red version 3RK1901-1AA01 1 1 unit 42C
AS-Interface sealing caps M12 3RK1901-1KA00 100 10 units 42C
For free M12 sockets
• Tamper proof 3RK1901-1KA01 100 10 units 42C
3RK1901- 3RK1901-
1KA00 1KA01
Accessories for SlimLine Compact safety modules
Device connectors
For the electrical connection of SlimLine Compact modules
(connects AS-i bus cable and 24 V DC auxiliary power supply
Uaux when using several SlimLine Compact modules)
• Width 17.5 mm 3RK1901-1YA00 1 1 unit 42C
• Width 22.5 mm 3RK1901-1YA10 1 1 unit 42C
Device termination connectors
3RK1901- 3RK1901- Required for the last module in the network
1YA00 1YA01 • Width 17.5 mm 3RK1901-1YA01 1 1 unit 42C
• Width 22.5 mm 3RK1901-1YA11 1 1 unit 42C
Removable terminals Screw terminals

• Screw terminals up to 2 x 1.5 mm2 or 1 x 2.5 mm2


- 2-pole 3ZY1121-1BA00 1 6 units 41L
- 4-pole 3ZY1141-1BA00 1 6 units 41L
Spring-loaded terminals
3ZY1121-2BA00 (push-in)
• Push-in terminals up to 2 x 1.5 mm2
- 2-pole 3ZY1121-2BA00 1 6 units 41L
- 4-pole 3ZY1141-2BA00 1 6 units 41L
Hinged cover 3ZY1450-1BA00 1 5 units 41L
Replacement for SlimLine Compact module,
without terminal labeling, width 17.5 mm, yellow
Push-in lugs for wall mounting 3ZY1311-0AA00 1 10 units 41L
Two lugs are required per device
Coding pins for removable terminals 3ZY1440-1AA00 1 12 units 41L
For mechanical coding of the terminals

3ZY1450-1BA00
Blank labels
Unit labeling plates1)
• 10 mm x 7 mm, titanium gray 3RT2900-1SB10 100 816 units 41B
IC01_00181

• 20 mm x 7 mm, titanium gray 3RT2900-1SB20 100 340 units 41B

3RT2900-1SB20
Tools for opening spring-loaded terminals Spring-loaded terminals
(push-in)
Screwdriver for SIRIUS devices with spring-loaded terminals 3RA2908-1A 1 1 unit 41B
3.0 mm x 0.5 mm, length approx. 200 mm,
3RA2908-1A titanium gray/black, partially insulated
1)
PC labeling system for individual inscription of unit labeling
plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


2/28 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC ET 200 > CM AS-i Master ST for SIMATIC ET 200SP

■ Overview
AS-i gateways with ET 200SP
An AS-i gateway or AS-i link enables access to the AS-Interface

2
data via PROFINET or PROFIBUS.
With the CM AS-i Master ST module, flexible and powerful
PROFINET/AS-i links or PROFIBUS/AS-i link solutions are set up.
Depending on the requirements, even several AS-i masters can
be plugged into one ET 200SP station, so that the setup can
easily be extended from a single master to double masters or
multiple masters.
The maximum number of modules is determined by the
ET 200SP interface module (IM): Up to 8 AS-i masters with
PROFINET IM 155-6PN Standard, up to 43 AS-i masters with
IM 155-6PN High Feature, or a single AS-i master with
IM 155-6PN Basic. For the connection to PROFIBUS,
the IM 155-6DP HF interface module with up to 7 AS-i master
modules is used.
Since in many plants an ET 200SP station with I/O, motor starter
CM AS-i Master ST for SIMATIC ET 200SP or other peripheral modules is provided, the AS-i master
modules are simply plugged in without any additional effort.
There are countless possible combinations.
An AS-i Safety gateway can also be implemented without
any problems by adding the safety-related module
F-CM AS-i Safety ST in the ET 200SP station. This greatly
simplifies the cabling and connection of distributed
Video: AS-Interface – Powerful integration in SIMATIC ET 200SP
EMERGENCY STOP pushbuttons and protective door
monitoring systems to a Failsafe CPU. The AS-i Safety
More information application is completely configured in TIA Portal/STEP 7.
SIMATIC ET 200SP Manual Collection, see
https://support.industry.siemens.com/cs/ww/en/view/84133942
The ET 200SP modules CM AS-i Master ST and
F-CM AS-i Safety ST (see page 2/34 onwards) can of course
Diagnostics blocks with visualization, see
https://support.industry.siemens.com/cs/ww/en/view/109479103
also be used directly on an ET 200SP CPU or F-CPU, so that an
extremely compact SIMATIC control system with AS-i bus
AS-Interface block library for SIMATIC PCS 7 for easy connection of
AS-Interface to PCS 7, see page 14/19 onwards
connection can be set up.
Released combinations of the AS-i modules for ET 200SP, see For further application possibilities, see the brochure
https://support.industry.siemens.com/cs/ww/en/view/103624653 "The modular AS-i master" at www.siemens.com/as-interface.
The CM AS-i Master ST communications module is designed for More information, see the
use in the SIMATIC ET 200SP distributed I/O system and has the SIMATIC ET 200SP Manual Collection.
following features:
Design
• Connection of up to 62 AS-Interface slaves
The CM AS-i Master ST module has an ET 200SP module
• Supports all AS-Interface master functions according to the
enclosure with a width of 20 mm. A type C0 BaseUnit (BU)
AS-Interface specification V3.0
is required for use in the ET 200SP.
• User-friendly configuration with graphic or tabular display of
the AS-i line in TIA Portal or STEP 7 (Classic) or via GSD in The communications module has LED displays for diagnostics,
other systems operation, AS-i voltage and AS-i slave status and offers
informative front-side module inscription for
• Supply via AS-Interface cable
• Plain-text marking of the module type and function class
• Suitable for AS-i Power24V and for AS-Interface with
30 V voltage • 2D matrix code (article and serial number)
• Integrated ground-fault monitoring for the AS-Interface cable • Circuit diagram
• Through connection to AS-Interface, the number of digital • Color coding module type communications module, light gray
inputs and outputs available for the control system is greatly • Hardware and firmware version
increased (max. 496 DI/496 DQ on the AS-Interface per • Supported BaseUnit type BU: C0
CM AS-i Master ST).
• Integrated analog value processing

Siemens IC 10 · 2023 2/29


© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC ET 200 > CM AS-i Master ST for SIMATIC ET 200SP
Function Configuration
The CM AS-i Master ST communications module supports all The following software is required for configuration of the
specified functions of the AS-Interface specification V3.0. CM AS-i Master ST module:
The input/output values of the digital AS-i slaves can be • STEP 7 (TIA Portal) or
2

activated via the cyclic process image. The values of the analog • STEP 7 (Classic) or
AS-i slaves are accessible via the cyclic process image or via • the GSD file of the ET 200SP with STEP 7 or another
data record transfer. engineering tool
If required, master calls can be performed with the command STEP 7 enables user-friendly configuration and diagnostics of
interface, e.g. read/write parameters, read/write configuration. the AS-i master and any connected slave modules.
Changeover of the operating mode, automatic application of Alternatively, you can also apply the AS-Interface ACTUAL
the slave configuration and the re-addressing of a connected configuration as the TARGET configuration at the "touch of
AS-i slave can be implemented via the control panel of the a button" via the control panel integrated in the TIA Portal or
CM AS-i Master ST in STEP 7. an optional expansion button. Configuration with the GSD file
For the implementation of modular machine concepts, is possible only with the button.
the AS-i slaves can be activated or deactivated via the PLC The CM AS-i Master ST module occupies up to 288 input
program (option handling). The configuration of AS-i slaves bytes and up to 288 output bytes in the I/O data of the
can be modified while being executed, thus enabling variable ET 200SP station. The I/O assignment depends on the
machine setups and tool changing with integrated input/output configuration in STEP 7.
modules during ongoing operation. AS-i input/output modules
can be added to the system without deactivating the controller. Together with an ET 200SP CPU 1510SP, 1512SP or 1515SP PC,
preprocessing of safe AS-i signals directly in the ET 200SP station
An existing AS-i installation can be read into the STEP 7 and setting up of an independent AS-i station without
hardware configuration and adapted and documented in the a higher-level CPU are possible.
project. Analog values are transmitted via the cyclic process
image, the length of which is adjustable and extendable up to
288 bytes (depending on the interface module (IM) used).
Diagnostics information is accessed via automatic alarm
indications, via the status information in the process image or
via the graphical status display in the online diagnostics of the
TIA Portal. The transmission quality of the AS-i network can also
be read out. To avoid configuration errors, duplicate addresses
can be detected on the AS-i network.
Configuration is possible with SIMATIC CPUs S7-300 up to
S7-1500 and with a SINUMERIK 840D sl or other controller.
The online diagnostic status of the AS-i slaves can be
displayed directly on the slaves in the network view in TIA Portal
(for S7-1500 CPUs with firmware version V 2.0 or higher).
Notes on security:
In order to protect plants, systems, machines and networks
against cyber threats, it is necessary to implement – and
continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens products and solutions represent Configuration of an AS-Interface network with CM AS-i Master ST via the
TIA Portal
only one component of such a concept.
For more information about the subject of Industrial Security,
see www.siemens.com/industrialsecurity.

2/30 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC ET 200 > CM AS-i Master ST for SIMATIC ET 200SP

■ Benefits
The CM AS-i Master ST for ET 200SP communications module For diagnostics during ongoing operation, diagnostics blocks
enables modular, simple and high-performance expansion of with clearly arranged visualization on the SIMATIC HMI panel are
AS-interface networks via engineering in the TIA Portal. available or can be downloaded free of charge via a web

2
browser, see
Up to eight CM AS-i Master ST units can be plugged into one https://support.industry.siemens.com/cs/ww/en/view/109479103.
ET 200SP station with IM 155-6PN Standard. When using the
IM 155-6 PN High Feature, the number of CM AS-i Master ST in
the ET 200SP station can be further increased. The maximum
configuration depends on the interface module used. Multiple
masters as well as single masters can thus be implemented in
the ET 200SP depending on the number of modules.
Together with the interface module, a scalable
PROFINET/AS-i link or PROFIBUS/AS-i link can be assembled.
Using STEP 7, the AS-i network is consistently configured and
programmed with only one configuration tool.
The PRONETA PC program (for ET 200SP with PROFINET
interface module) is available for convenient input/output testing
during the commissioning of an AS-i network without a CPU; see
www.siemens.com/proneta.
For the connection of an AS-i network to systems with Ethernet/IP
and Modbus TCP, the ET 200SP MultiFieldbus interface module
IM155-6MF in combination with the CM AS-i Master ST module CM AS-i Master ST diagnostics block
is available.

Siemens IC 10 · 2023 2/31


© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC ET 200 > CM AS-i Master ST for SIMATIC ET 200SP

■ Application
Configuration examples of AS-Interface networks with CM AS-i Master ST for SIMATIC ET 200SP
2

Controller
e.g. SIMATIC S7-1500
or SIMATIC S7-300
or SINUMERIK 840D sl

PROFINET PROFIBUS
SIMATIC ET 200SP SIMATIC ET 200SP
with 2 x CM AS-i Masters ST with CM AS-i Master ST
AS-Interface AS-Interface AS-Interface
power supply power supply power supply

AS-Interface AS-Interface AS-Interface

IC01_00237e
1 2 3 4 5 1 2 3 4 5

1 Pushbuttons and indicator lights 4 M200D motor starter


2 Field module 5 Signal column
3 3RA2 load feeder

Configuration of AS-Interface networks under a SIMATIC ET 200SP

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

CM AS-i Master ST communications module 3RK7137-6SA00-0BC1 1 1 unit 42C


• AS-Interface master for SIMATIC ET 200SP,
can be plugged onto BaseUnit type C0
• Corresponds to AS-Interface specification V3.0
• Dimensions W x H x D (mm): 20 x 73 x 58

3RK7137-6SA00-0BC1

* You can order this quantity or a multiple thereof.


2/32 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC ET 200 > CM AS-i Master ST for SIMATIC ET 200SP

■ Accessories
Version Spring-loaded PU PS* PG
terminals (UNIT,
SET, M)

2
Article No. Price
per PU
BaseUnit BU20-P6+A2+4D 6ES7193-6BP20-0DC0 1 1 unit 255
• BaseUnit (light), BU type C0
• Suitable for the CM AS-i Master ST module
• For connection of the AS-Interface cable to
the CM AS-i Master ST
• Start of an AS-i network, isolation of the
AS-i voltage from the left-hand module

6ES7193-6BP20-0DC0

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

PROFINET IM 155-6PN Basic interface modules


Max. 12 I/O modules,
max. 32 bytes of I/O data per station
• Including server module and 2 x RJ45 ports 6ES7155-6AR00-0AN0 1 1 unit 255
(supplied without RJ45 plug)
PROFINET IM 155-6PN Standard interface modules
Max. 32 I/O modules,
max. 256 bytes I/O data per station
• Including server module and bus adapter 2 x RJ45 6ES7155-6AA01-0BN0 1 1 unit 255
6ES7155- 6ES7155- (supplied without RJ45 plug)
6AR00-0AN0 6AA01-0BN0 • Including server module 6ES7155-6AU01-0BN0 1 1 unit 255
(bus adapter must be ordered separately, see below)
PROFINET IM 155-6PN High Feature interface modules
Max. 64 I/O modules,
max. 1 440 bytes I/O data per station
• IM 155-6PN/2 High Feature 6ES7155-6AU01-0CN0 1 1 unit 255
2-port IM with a bus adapter slot, including server
module and optional strain relief (bus adapter must be
ordered separately, see below)
• IM 155-6PN/3 High Feature 6ES7155-6AU30-0CN0 1 1 unit 255
3-port IM with two bus adapter slots,
including server module and optional strain relief
6ES7155-6AU01-0CN0 (bus adapter must be ordered separately, see below)
PROFINET IM 155-6PN High Speed interface modules
Max. 30 I/O modules,
max. 1 440 bytes I/O data per station
• Including server module 6ES7155-6AU00-0DN0 1 1 unit 255
(bus adapter must be ordered separately, see below)
PROFIBUS IM 155-6DP High Feature interface modules
Max. 32 I/O modules,
max. 244 bytes I/O data per station
• Including server module and PROFIBUS plug 6ES7155-6BA01-0CN0 1 1 unit 255
6ES7155-6AU00-0DN0
MultiFeldbus interface modules IM 155-6MF
High Feature
For operation on PROFINET, EtherNet/IP or Modbus TCP
controllers, 1 slot for bus adapter, max. 64 I/O modules
• Including server module and optional strain relief 6ES7155-6MU00-0CN0 1 1 unit 255
(bus adapter must be ordered separately, see below)
For more information, see
https://support.industry.siemens.com/cs/ww/de/view/
109779189.
6ES7155-6MU00-0CN0
Bus adapters for PROFINET/Ethernet
For connection of the Ethernet cable to the
PROFINET IM 155-6PN interface module and
the MultiFieldbus IM 155-6MF interface module
• Connection 2 x RJ45 (supplied without RJ45 plug) 6ES7193-6AR00-0AA0 1 1 unit 255
• Connection 2 x FC (FastConnect) 6ES7193-6AF00-0AA0 1 1 unit 255
For more bus adapters with fiber-optic cable connection,
see Industry Mall.

6ES7193- 6ES7193-
6AR00-0AA0 6AF00-0AA0

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/33
© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC ET 200 > F-CM AS-i Safety ST for SIMATIC ET 200SP

■ Overview
• Simple module replacement thanks to automatic importing of
the safety parameters from the coding element
2

• Comprehensive diagnostics options


• Can be plugged onto type C1 or type C0 BaseUnits (BU)
• Informative automatic alarm indications
• Supply via AS-Interface voltage
• Eight LED displays for diagnostics, operating state, fault
indication and supply voltage
• Informative front-side module inscription
- Plain-text marking of the module type and function class
- 2D matrix code (article and serial number)
- Circuit diagram
- Color coding module type communications module:
light gray
- Hardware and firmware version
- Supported BaseUnit type BU: C1, C0
F-CM AS-i Safety ST for SIMATIC ET 200SP Design
More information The fail-safe F-CM AS-i Safety ST module has an ET 200SP
module enclosure with a width of 20 mm.
SIMATIC ET 200SP Manual Collection, see
https://support.industry.siemens.com/cs/ww/en/view/84133942 One AS-i master according to the AS-i specification V3.0 and
Diagnostics blocks with visualization, see safe AS-i input slaves and/or safe AS-i output modules are
https://support.industry.siemens.com/cs/ww/en/view/109479103 needed for operation. The CM AS-i Master ST communications
Released combinations of the AS-i modules for ET 200SP, see module (article number 3RK7137-6SA00-0BC1) is
https://support.industry.siemens.com/cs/ww/en/view/103624653 recommended as the AS-i master for the ET 200SP,
see page 2/29 onwards.
The F-CM AS-i Safety ST fail-safe communications module
supplements an AS-Interface network without additional wiring Simple combination of the CM AS-i Master ST and
to produce a safety-related AS-i network. F-CM AS-i Safety ST modules in one ET 200SP station results in
a powerful, safety-related network transition between PROFINET
Important features: (or PROFIBUS) and AS-Interface, which can be expanded
• Fail-safe communications module for the ET 200SP further in a modular fashion.
- 31 fail-safe input channels in the process image
- 16 fail-safe output channels in the process image
- Certified up to SIL 3 (IEC 62061)/PL e (ISO 13849-1)
- Parameterization conforms with other Failsafe I/O modules
of the ET 200SP
• The communications module supports PROFIsafe in
PROFINET and PROFIBUS configurations. Can be
used with fail-safe SIMATIC S7-300F/S7-400F CPUs and
S7-1500F CPUs and also the Failsafe versions of the
ET 200SP station with ET 200SP F-CPU 1510SP F, 1512SP F
or 1515SP PC F.
• For reading up to 31 fail-safe AS-i input slaves
- Two sensor inputs/signals for each fail-safe AS-i input slave
- Adjustable evaluation of sensor signals: 2-channel or
2 x 1-channel
- Integrated discrepancy evaluation in the case of 2-channel
signals
- Integrated AND operation in the case of 2 x 1-channel signals
- Input delay can be parameterized Combination of an ET 200SP interface module, CM AS-i Master ST and
- Start-up test can be set F-CM AS-i Safety ST
- Sequence monitoring can be activated With the digital and analog I/O modules of the ET 200SP,
• For control of up to 16 fail-safe AS-i output circuit groups additional local inputs and outputs can be realized so as to
- The output circuit groups are controlled independently of ensure that the modular AS-i router complies precisely with
one another. customer requirements. Expansion variants for almost every
- One output circuit group can act on one or more actuators application are possible thanks to the selection of standard and
(e.g. to switch drives simultaneously). Failsafe I/O modules.
- The F-CM AS-i Safety ST module transmits the switching Besides the single AS-i master, double, triple or generally
command of the output circuit group on the AS-i cable. multiple masters can be realized with or without Failsafe
A safe AS-i output module that is installed at any point functionality.
on the AS-i cable receives the switching command and
switches the connected actuator (e.g. contactor).
- Simple fault acknowledgment via the process image

2/34 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC ET 200 > F-CM AS-i Safety ST for SIMATIC ET 200SP
Supported BaseUnits The input and output channels are assigned to the process
image automatically and manual linking via configuration blocks
With the combination of the CM AS-i Master ST and is not necessary.
F-CM AS-i Safety ST modules, the CM module is plugged onto
a light type C0 BaseUnit and, immediately to the right of it, If the F-CM AS-i Safety ST module is replaced, all necessary

2
the F-CM module is plugged onto a dark type C1 BaseUnit. settings are automatically imported into the new module.
The AS-i cable is connected only on the light BaseUnit of the
CM module. The F-CM AS-i Safety ST module occupies 16 input bytes and
8 output bytes in the I/O data of the ET 200SP station.
Notes on security:
For diagnostics during ongoing operation, diagnostics blocks
In order to protect plants, systems, machines and networks with clearly arranged visualization on the SIMATIC HMI panel are
against cyber threats, it is necessary to implement – and available or can be downloaded free of charge via a web
continuously maintain – a holistic, state-of-the-art industrial browser, see
security concept. Siemens products and solutions represent https://support.industry.siemens.com/cs/ww/en/view/109479103.
only one component of such a concept.
For more information about the subject of Industrial Security,
see www.siemens.com/industrialsecurity.
Configuration
The following software is required for configuration of the
F-CM AS-i Safety ST module:
• STEP 7 (TIA Portal) and Safety Advanced or
• STEP 7 (Classic) and Distributed Safety or F-Configuration
Pack SP11 or SIMATIC S7 F/FH systems
Configuration and programming are done entirely in the
STEP 7 user interface. No additional configuration software
is needed for commissioning.
Data management – together with all other configuration data of
the SIMATIC – is realized completely in the S7 project.
Diagnostics block for F-CM AS-i Safety ST

■ Application
Thanks to use of the fail-safe module in the ET 200SP, it is The fail-safe output signals can be output via safe
possible to fulfill the safety-related application requirements in SIMATIC output modules or also directly via AS-i output
a manner that is integrated in the overall automation solution. modules. No special functions are required for this in
the program.
The safety functions required for fail-safe operation are
integrated in the modules. Communication with the fail-safe Operation with SINUMERIK 840D sl is possible with
SIMATIC S7 CPUs is realized via PROFIsafe. SINUMERIK software version V4.7 SP2 HF1 or higher.
The safety application is programmed in the SIMATIC S7 F-CPU Together with an ET 200SP station with ET 200SP F-CPU
with Distributed Safety, S7 F/FH Systems or Safety Advanced. 1510SP F, 1512SP F or 1515SP PC F, pre-processing of safe
The fail-safe input signals of the ASIsafe slave modules are read AS-i signals directly in the ET 200SP station is possible, as well
via the AS-i bus line and are combined with any chosen further as the configuration of an autonomous AS-i Safety station
signals in the fail-safe program. without a higher-level CPU.

Siemens IC 10 · 2023 2/35


© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC ET 200 > F-CM AS-i Safety ST for SIMATIC ET 200SP
Configuration examples of AS-Interface networks with CM AS-i Master ST and F-CM AS-i Safety ST for SIMATIC ET 200SP

Operational Safety-oriented
control processing
2

Safe control
e.g. SIMATIC S7-1500F
or SIMATIC S7-300F/S7-400F
PROFINET/PROFIsafe or SINUMERIK 840D sl

ET 200SP with ET 200SP with


CM AS-i Master ST and CM AS-i Master ST and
F-CM AS-i Safety ST F-CM AS-i Safety ST
AS-Interface AS-Interface AS-Interface
power supply power supply power supply
AS-Interface/ AS-Interface/ AS-Interface/
ASIsafe ASIsafe ASIsafe

IC01_00288f
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6

1 Safe EMERGENCY STOP 4 Signal column


2 Safety switch with tumbler 5 Digital K45 field module
3 Field module 6 3RA2 load feeder

AS-Interface configuration comprising an ET 200SP station with CM AS-i Master ST and F-CM AS-i Safety ST modules

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

F-CM AS-i Safety ST communications module 3RK7136-6SC00-0BC1 1 1 unit 42C


• Fail-safe module for SIMATIC ET 200SP, can be plugged
onto BaseUnit type C1 (alternatively type C0)
• Operation requires an AS-i master, e.g.
CM AS-i Master ST (see page 2/29 onwards)
• Can be used up to SIL 3 (IEC 62061)/PL e (ISO 13849-1)
• Coding element type H (included in scope of supply)
• Dimensions W x H x D (mm): 20 x 73 x 58

3RK7136-6SC00-0BC1

■ Accessories
Version Spring-loaded PU PS* PG
terminals (UNIT,
SET, M)
Article No. Price
per PU
BaseUnit BU20-P6+A2+4B 6ES7193-6BP20-0BC1 1 1 unit 255
• BaseUnit (dark), BU type C1
• Suitable for the F-CM AS-i Safety ST fail-safe
communications module
• Continuation of an AS-i network, connection with
the AS-i voltage of the left-hand module

6ES7193-6BP20-0BC1
Coding element type H (spare part) 6ES7193-6EH00-1AA0 1 5 units 256
• For the ET 200SP modules F-CM AS-i Safety ST and
CM 4xIO-Link
• Packing unit 5 items

More accessories, see page 2/33.

* You can order this quantity or a multiple thereof.


2/36 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC S7 > CM 1243-2

■ Overview Function
The CM 1243-2 supports all specified functions of the
AS-Interface specification V3.0.
The values of the digital AS-i slaves can be activated via the

2
process image of the S7-1200. During configuration of the
slaves in the TIA Portal, the values of the analog AS-i slaves can
also be accessed directly in the process image.
If required, master calls can be performed with the data record
interface, e.g. read/write parameters, read/write configuration.
Changeover of the operating mode, automatic application of
the slave configuration and the re-addressing of a connected
AS-i slave can be implemented via the control panel of the
CM 1243-2 in the TIA Portal.
The optional DCM 1271 data decoupling module (see
"Accessories", page 2/38) has an integrated detection unit
for detecting ground faults on the AS-Interface cable.
The integrated overload protection also disconnects the
AS-Interface cable if the drive current required exceeds 4 A.
For more information on DCM 1271, see page 2/73.
CM 1243-2 communications module for S7-1200
Notes on security:
More information
In order to protect plants, systems, machines and networks
Equipment Manual for AS-i master CM 1234-2 and AS-i DCM 1271 against cyber threats, it is necessary to implement – and
decoupling module, see continuously maintain – a holistic, state-of-the-art industrial
https://support.industry.siemens.com/cs/ww/en/view/57358958
security concept. Siemens products and solutions represent
The CM 1243-2 communications module is the AS-Interface only one component of such a concept.
master for the SIMATIC S7-1200 and has the following features: For more information about the subject of Industrial Security,
• Connection of up to 62 AS-Interface slaves see www.siemens.com/industrialsecurity.
• Integrated analog value transmission Configuration
• Supports all AS-Interface master functions in accordance with The TIA Portal enables user-friendly configuration and
the AS-Interface specification V3.0 diagnostics of the AS-Interface master and any connected
• Indication of the operating state on the front of the device slave modules.
displayed via LED
When operated on an S7-1200 CPU with firmware version V4.0
• Display of operating mode, AS-Interface voltage faults, or higher, the firmware version V1.1 (or higher) is required for the
configuration faults and peripheral faults via LED behind CM 1243-2.
the front panel
• Compact enclosure in the design of the SIMATIC S7-1200 ■ Benefits
• Suitable for AS-i Power24V and for AS-Interface with 30 V
• More flexibility and versatility in the use of SIMATIC S7-1200
voltage: A standard 24 V power supply unit can be used in
as the result of a significant increase in the number of digital
combination with the optional DCM 1271 data decoupling
and analog inputs/outputs available
module.
• Very easy configuration and diagnostics of the AS-Interface
• Configuration and diagnostics via the TIA Portal
via the TIA Portal
Design • Simple operation with AS-Interface power supply unit
The CM 1243-2 communications module is positioned to the left (see page 2/67) possible without restrictions.
of the S7-1200 CPU and linked to the S7-1200 via lateral contacts. • Alternatively: No need for the AS-i power supply unit with
AS-i Power24V. The AS-Interface cable is supplied through
It has: an existing 24 V DC PELV power supply unit. For decoupling,
• Terminals for two AS-i cables (internally jumpered) via two the AS-i DCM 1271 data decoupling module is required,
screw terminals see "Accessories" and page 2/73.
• One terminal for connection to the functional ground • LEDs for indication of fault statuses for fast diagnostics
• LEDs for indication of the operating state and fault statuses of • Monitoring of AS-Interface voltage facilitates diagnostics
the connected slaves
The screw terminals (included in scope of supply) can be
removed to facilitate installation.

Siemens IC 10 · 2023 2/37


© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC S7 > CM 1243-2

■ Application
The CM 1243-2 is the AS-Interface master connection for Operating conditions
the 12xx CPUs of the SIMATIC S7-1200. Through connection to • The CM 1243-2 communications module exchanges data with
AS-Interface, the number of digital inputs and outputs available
2

the S7-1200 CPU with a cycle time of 10 ms.


for the S7-1200 is greatly increased (max. 496 DI/496 DQ on
the AS-Interface per CM). • The AS-i cycle time depends on the AS-i bus capacity
and is up to 5 ms in the case of 31 slaves addresses;
The integrated analog value processing also makes the analog for more information, see Equipment Manual for AS-i master
values available at the AS-Interface for the S7-1200. Up to CM 1243-2 and AS-i DCM 1271 data decoupling module,
31 analog slaves with a standard address (each with up to https://support.industry.siemens.com/cs/ww/en/view/57358958.
four channels) or up to 62 analog slaves with an A/B address • For calculation of the maximum switching frequency
(each with up to two channels) are possible per CM. at inputs/outputs of AS-i slaves, these cycle times and
the runtime of the user program must be added up.

■ Selection and ordering data


Version Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price
per PU
CM 1243-2 communications module 3RK7243-2AA30-0XB0 1 1 unit 42C
• AS-Interface masters for SIMATIC S7-1200
• Corresponds to AS-Interface specification V3.0
• Removable terminals (included in the scope of supply)
• Dimensions W x H x D (mm): 30 x 100 x 75

3RK7243-2AA30-0XB0
Note:
The CM 1243-2 communications module is available as
a SIPLUS version under article number 6AG1243-2AA30-7XB0
in the extended temperature range (from -25 to +70 °C) and for
use in harsh environmental conditions (coated according to
environment standard IEC 60721).
For more information, see www.siemens.com/siplus-extreme.

■ Accessories
Version Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price
per PU
DCM 1271 data decoupling module 3RK7271-1AA30-0AA0 1 1 unit 42C
• Max. 1 x 4 A
• Removable terminals (included in the scope of supply)
• Dimensions W x H x D (mm): 30 x 100 x 75
Screw terminals (spare part)
• 5-pole, 3RK1901-3MA00 1 1 unit 42C
For AS-i master CM 1243-2 and AS-i DCM 1271 data
decoupling module
• 3-pole, 3RK1901-3MB00 1 1 unit 42C
3RK7271-1AA30-0AA0 For AS-i DCM 1271 data decoupling module for
connecting the power supply unit

* You can order this quantity or a multiple thereof.


2/38 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC S7 > CP 343-2P/CP 343-2

■ Overview
Design
The CP 343-2P/CP 343-2 is connected like an I/O module to

2
the S7-300. It has:
• Two terminal connections for connecting the AS-Interface
cable directly.
• LEDs in the front panel for indicating the operating state and
the readiness for operation of all connected and activated
slaves
• Pushbuttons for switching over the master operating state
and for adopting the existing ACTUAL configuration of
the AS-i slave as the TARGET configuration
Function
The CP 343-2P/CP 343-2 supports all specified functions of
the AS-Interface specification V3.0.
Each CP 343-2P/CP 343-2 occupies 16 bytes in the I/O address
area of the SIMATIC S7-300. The digital I/O data of the standard
CP 343-2P/CP 343-2 slaves and A slaves are saved in this area. The digital I/O data
of the B slaves and the analog I/O data can be accessed with
More information the S7 system functions for read/write data records.
Manuals, see https://support.industry.siemens.com/cs/ww/en/ps/15754/man If required, master calls can be performed with the command
For diagnostics during ongoing operation, diagnostics blocks with clearly interface, e.g. read/write parameters, read/write configuration.
arranged visualization on the SIMATIC HMI panel are available or can be
downloaded free of charge via a web browser, see For more information, see
https://support.industry.siemens.com/cs/ww/en/view/61892138 https://support.industry.siemens.com/cs/ww/en/view/51678777.
AS-Interface block library for SIMATIC PCS 7 for easy connection of
AS-Interface to PCS 7, see page 14/19 onwards Notes on security:

The CP 343-2P communications processor is the AS-Interface In order to protect plants, systems, machines and networks
master for the SIMATIC S7-300 and the ET 200M distributed against cyber threats, it is necessary to implement – and
I/O station, with user-friendly parameterizing options. continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens products and solutions represent
The CP 343-2 is the basic version of the module. only one component of such a concept.
The CP 343-2P/CP 343-2 has the following characteristics: For more information about the subject of Industrial Security,
• Connection of up to 62 AS-Interface slaves see www.siemens.com/industrialsecurity.
• Integrated analog value transmission Configuration
• Support of all AS-Interface master functions in accordance All connected AS-Interface slaves are configured at the press
with the AS-Interface specification V3.0 of a button. No further configuration of the CP is required.
• Status displays of operating states and indication of the
Additionally for CP 343-2P
readiness for operation of connected slaves by means of
LEDs in the front panel The CP 343-2P also supports configuring of the AS-Interface
• Fault indications (including AS-Interface voltage errors, network with STEP 7. Specifying the AS-i configuration in
configuration errors) by means of LEDs on the front plate. HW Config facilitates the setting of slave parameters and
documentation of the plant. Uploading the ACTUAL
• Compact enclosure in the design of the SIMATIC S7-300 configuration of an already configured AS-Interface network is
• Suitable for AS-Interface with 30 V voltage and AS-i Power24V also supported. The saved configuration cannot be overwritten
• Additionally for CP 343-2P: Supports the configuration of the at the press of a button and is therefore tamper-proof.
AS-Interface network with STEP 7

■ Benefits
• Shorter startup times through simple configuration at the press • Lower costs for stock keeping and spare parts inventory
of a button because the CP can be used for the SIMATIC S7-300 and also
• Design of flexible machine-related structures using the for the ET 200M
ET 200M distributed I/O system • Additionally for CP 343-2P: Improved plant documentation
• Provides diagnostics of the AS-Interface network and support for service assignments thanks to a description
of the AS-Interface configuration in the STEP 7 project
• Well suited also for complex applications thanks to connection
options for 62 slaves and integral analog value processing • Simple operation with AS-Interface power supply unit
(see page 2/67) possible without restrictions.
• Reduction of standstill and servicing times in the event of
a fault thanks to the LED displays: • Alternatively: No need for the AS-i power supply unit with
- Status of the AS-Interface network AS-i Power24V. The AS-Interface cable is supplied through an
- Slaves connected and their readiness for operation existing 24 V DC PELV power supply unit. An S22.5 AS-i data
- Monitoring of the AS-Interface voltage decoupling module (e.g. 3RK1901-1DE12-1AA0) is required
for the decoupling, see page 2/71.

Siemens IC 10 · 2023 2/39


© Siemens 2023

Industrial communication
AS-Interface
Masters
Masters for SIMATIC S7 > CP 343-2P/CP 343-2

■ Application
The CP 343-2P/CP 343-2 is the AS-Interface master connection The CP 343-2P is the further development of the CP 343-2 and
for SIMATIC S7-300 and ET 200M. contains its entire functionality. An existing STEP 7 user program
for a CP 343-2 can thus be used without restrictions with
2

Through connection to AS-Interface it is possible to access max. a CP 343-2P. It is only in STEP 7 HW Config that the two modules
248 DI/248 DQ per CP, using 62 A/B slaves with 4 DI/4 DQ each. are configured differently, with the CP 343-2P offering additional
With the integrated analog value processing, it is easy to options. This is why the CP 343-2P is recommended.
transmit analog signals. Up to 62 analog slaves with an
A/B address (each with up to two channels) or up to 31 analog
slaves with a standard address (each with up to four channels)
are possible per CP.

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

CP 343-2P communications processors 6GK7343-2AH11-0XA0 1 1 unit 42C


• Device version with expanded configuration options
for connection of SIMATIC S7-300 and ET 200M to
AS-Interface
• Configuration of the AS-i network using the SET key
or STEP 7
• Without front connector
• Corresponds to AS-Interface specification V3.0
6GK7343-2AH11-0XA0 • Dimensions W x H x D (mm): 40 x 125 x 120
CP 343-2 communications processors 6GK7343-2AH01-0XA0 1 1 unit 42C
• Basic version for connection of SIMATIC S7-300 and
ET 200M to AS-Interface
• Configuration of the AS-i network using the SET key
• Without front connector
• Corresponds to AS-Interface specification V3.0
• Dimensions W x H x D (mm): 40 x 125 x 120

6GK7343-2AH01-0XA0

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Front connector, 20-pole


• With screw terminals 6ES7392-1AJ00-0AA0 1 1 unit 230

• With spring-loaded terminals 6ES7392-1BJ00-0AA0 1 1 unit 230

* You can order this quantity or a multiple thereof.


2/40 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Routers
DP/AS-Interface Link 20E

■ Overview
Routers
High-performance routers between PROFINET and AS-Interface

2
and between PROFIBUS and AS-Interface can be set up by
combining the CM AS-i Master ST and F-CM AS-i Safety ST
modules in an ET 200SP station (for safety-related applications),
see pages 2/29 and 2/34.
Design
• Compact plastic enclosure in degree of protection IP20 for
DIN-rail mounting
• LEDs in the front panel for indicating the operating state and
functional readiness of all connected slaves
• Setting of PROFIBUS DP address is possible by pressing
a button
• LED display of the PROFIBUS DP slave address,
PROFIBUS DP bus faults and diagnostics
• Two pushbuttons for switching over the operating state
and for adopting the existing ACTUAL configuration as
DP/AS-Interface Link 20E manual
the TARGET configuration
More information
Functionality
Manual for DP/AS-Interface Link 20E, see
https://support.industry.siemens.com/cs/ww/en/view/5281638 Communication
The DP/AS-Interface Link 20E enables a DP master to access all
PN DP-M DP-S AS-i M the slaves of an AS-Interface network.
The DP/AS-Interface Link 20E occupies a standard 32 bytes
IK10_10195a

of input data and 32 bytes of output data in which the digital


I/O data of the connected AS-Interface slaves (standard and
DP/AS-Interface Link 20E connects PROFIBUS DP to A/B addressing) of an AS-i line is stored.
AS-Interface and has the following features: The size of the input/output image can be compressed so
• PROFIBUS DP slave and AS-Interface master that only the actually required I/O address area is occupied
in the system of the PROFIBUS DP master.
• Up to 62 AS-Interface slaves, each with four digital inputs and
four digital outputs as well as analog slaves can be connected The analog I/O data can be accessed with the S7 system
• Integrated analog value transmission functions for read/write data records.
• Supports all AS-Interface master functions according to the Configuration
AS-Interface specification V3.0
The DP/AS-Interface Link 20E is configured as follows:
• Supply from AS-Interface cable; hence no additional power
• With STEP 7 (TIA Portal) or STEP 7 (Classic)
supply required
In the case of STEP 7 configuration, the AS-Interface
• Suitable for AS-i Power24V (from product version 2/ configuration can be uploaded in STEP 7. Furthermore,
firmware version 3.1) and for AS-Interface with 30 V voltage AS-Interface slaves from Siemens can also be conveniently
• Supports uploading of the AS-Interface configuration configured in HW Config (slave selection dialog).
in STEP 7 • By adopting the ACTUAL configuration of the AS-Interface by
using the SET pushbutton on the front panel.
• Alternatively, DP/AS-Interface Link 20E can be integrated
by means of the PROFIBUS GSD file in the engineering tool
(e.g. for non-Siemens engineering tools).

■ Benefits
• Reduction of installation costs because the power is supplied • Quick and easy commissioning by reading the AS-Interface
entirely via the AS-Interface cable, which means that no configuration
additional power supply is required • For diagnostics during ongoing operation, diagnostics blocks
• Short startup times thanks to easy configuration at the touch with clearly arranged visualization on the SIMATIC HMI panel
of a button are available or can be downloaded free of charge via a web
• The LED displays help reduce downtime and service times if browser; see
a slave fails https://support.industry.siemens.com/cs/ww/en/view/61892138.

Siemens IC 10 · 2023 2/41


© Siemens 2023

Industrial communication
AS-Interface
Routers
DP/AS-Interface Link 20E

■ Application
The DP/AS-Interface Link 20E is a PROFIBUS DP slave PROFIBUS DP masters (DP-V0) can exchange digital I/O data
(according to IEC 61158/IEC 61784) and an AS-Interface cyclically with the AS-Interface.
master (according to IEC 62026-2). It enables the AS-Interface
2

to be operated on PROFIBUS DP. PROFIBUS DP masters with acyclic services (DP-V1)


are additionally able to exchange analog I/O data and
Up to 248 DI/248 DQ can be operated via the initiate AS-Interface master calls (e.g. reading/writing
DP/AS-Interface Link 20E using 62 A/B slaves with the AS-i configuration during normal operation).
4 DI/4 DQ each.

S7-400
e.g. with
CP 443-5 Extended
S7-1500 with DP-Master S7-300 with DP-Master

PROFIBUS
DP/AS-Interface
Link 20E

AS-Interface

IK10_40008c
AS-Interface Digital and analog input/output modules 3RA2 load feeder Pushbuttons Signal column
power supply with 3RA27 function Indicator lights
unit module

Transition from PROFIBUS DP to AS-Interface using DP/AS-Interface Link 20E

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

DP/AS-Interface Link 20E


Router between PROFIBUS DP and AS-Interface in Screw terminals
degree of protection IP20;
including screw terminals for connection 6GK1415-2AA10 1 1 unit 42C
of the AS-Interface cable;
corresponds to AS-Interface specification V3.0;
dimensions W x H x D (mm): 90 x 80 x 60
(dimensions without fixing lugs)

6GK1415-2AA10

* You can order this quantity or a multiple thereof.


2/42 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Routers
DP/AS-Interface Link 20E

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

2
PROFIBUS FC standard cable GP 6XV1830-0EH10 1 1M 5K1
FastConnect standard type with special design
for fast installation, 2-core, shielded
PROFIBUS FastConnect bus connector
With insulation displacement connection, max. transmission rate
12 Mbps, activatable terminating resistor integrated
• RS 485 bus connector with 90° cable outlet
- Without PG connection socket 6ES7972-0BA52-0XA0 1 1 unit 250
- With PG connection socket 6ES7972-0BB52-0XA0 1 1 unit 250
• RS 485 bus connector with diagonal cable outlet (35°)
- Without PG connection socket 6ES7972-0BA61-0XA0 1 1 unit 250
- With PG connection socket 6ES7972-0BB61-0XA0 1 1 unit 250
PROFIBUS FastConnect stripping tool 6GK1905-6AA00 1 1 unit 5K2
Preset stripping tool for speedy stripping of
PROFIBUS FastConnect bus cables

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/43
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Digital I/O modules, IP67 - Introduction

■ Overview
Connection types
For flexible connection of different sensors and actuators,
2

the following pin assignments are available on the I/O modules


with M12 sockets:
Standard assignment
With the standard assignment, one sensor/actuator is connected
per M12 socket. In this case the signal for the outputs is
acquired at pin 4 while the signal for the inputs is acquired at
pin 4 and pin 2. As the result, sensors can be connected directly
to pin 2 and pin 4.
Y-assignment
With the Y-assignment, two sensors or two actuators can be
connected to one M12 socket. In this case, both pin 4 and pin 2
are provided for one sensor signal and one actuator signal on
each M12 socket.
K60
In this case, the second socket is not required and is closed with
a sealing cap.
Y-II assignment
The Y-II assignment offers the following options:
• Individual connection of a sensor/actuator to one M12 socket
• Connection of two sensors/actuators to one M12 socket
as follows:
- The signal of the first sensor/actuator is connected to pin 4
of the first socket.
- The signal of the second sensor/actuator is connected to
pin 2 of the first socket and to pin 4 of the second socket.
Overview of digital compact modules
K45
The following table provides an overview of the important
features of the digital compact modules.
.

Version K60 K45 K20


8 inputs/2 outputs ✓ -- --
8 inputs ✓ ✓ --
4 inputs/4 outputs ✓ ✓ ✓
4 inputs/3 outputs ✓ -- --
4 inputs/2 outputs ✓ -- --
4 inputs ✓ ✓ ✓
2 inputs/2 outputs -- ✓ ✓
4 outputs ✓ ✓ ✓
3 outputs -- ✓ --
AS-Interface connection Flat cable/ Flat cable Round cable
round cable
I/O connection method M12 M12/M8 M12/M8
K20 Pin assignment Standard/Y-II/Y Standard/Y Standard/Y
Degree of protection IP65/IP67/IP68/ IP65/IP67 IP65/IP67
Three coordinated series of AS-Interface compact modules with IP69 (IP69K)
digital and analog compact modules and a high degree of
Addressing type ✓ ✓ ✓
protection are available for use in the field: A/B address
• Digital modules with a high degree of protection ✓ Available
- Series K60, see pages 2/46 and 2/48
-- Not available
- Series K45, see page 2/51
- Series K20, see page 2/52 For safety modules for AS-Interface, see page 2/27.
• Analog modules with a high degree of protection
- Series K60, see page 2/55
All compact modules are characterized by particularly
simple handling. The K60 and K45 modules are mounted with
a mounting plate. The mounting plate is used to mount the
AS-Interface flat cables and enables mounting on a wall
or DIN rail.
The particularly narrow K20 modules are directly mounted
without a mounting plate and connected to the AS-Interface
using a round cable.

2/44 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Digital I/O modules, IP67 - K60

■ Overview
Addressing and connection of the sensors/actuators
Addressing of the K60 modules is performed using an

2
addressing socket integrated in the compact module.
The addresses can also be assigned after installation.
K60 modules with a maximum of four digital inputs and outputs
These compact modules contain the M12 standard connections
for inputs and outputs. Using M12 standard plugs, a maximum
of four sensors and four actuators can be connected to the
compact module.
K60 compact modules with a maximum of eight digital inputs
These modules have eight digital inputs for connection through
M12 plugs.
The module requires two AS-Interface addresses for processing
all eight inputs. The addressing can thus be performed through
a double addressing socket integrated in the module.
K60
The K60 digital AS-Interface compact modules are K60 data couplers
characterized by optimized handling characteristics and An AS-Interface data coupler has been added to the K60
user-friendliness. They permit the mounting times and startup compact module range. Integrated in this module are two
times of AS-Interface to be reduced by up to 40%. AS-i slaves which are connected to two different AS-i networks.
Each of the two integrated slaves has four virtual inputs and four
Mounting and connection of the AS-Interface shaped cables virtual outputs. The bidirectional data transmission of four data
Assembly of the K60 modules is performed with a mounting bits between two AS-i networks is thus possible in a simple and
plate which accommodates the AS-Interface shaped cables. cost-effective manner. The data coupler needs its own address
Two different mounting plates are offered for in each AS-i network. The data coupler is supplied with power
• Wall mounting directly from the AS-i cable.
• DIN-rail mounting Each AS-i network works with a different cycle time depending
on the number of stations. Hence two AS-i networks are not
The mounting plate and the compact module are joined together necessarily synchronous. For this reason, the AS-i data coupler
by means of a screw, with simultaneous contacting of the can be used to transmit only standard data and no safety data.
AS-Interface cable by the service-proven insulation piercing
method.

Siemens IC 10 · 2023 2/45


© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Digital I/O modules, IP67 - K60

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)
2

Digital I/O modules, IP67 - K60


• PNP transistor
• Width 60 mm
• Connection method: M12
• Modules supplied without mounting plate
Type Current- Slave Pin Sensor
carrying addressing assign- power
capacity of type ment supply via
outputs
3RK1400- 8 inputs/ 2A A/B Special AS-i 3RK2400-1HQ00-0AA3 1 1 unit 42C
1DQ00-0AA3 2 outputs1)
8 inputs1) -- Standard Y-II AS-i 3RK1200-0DQ00-0AA3 1 1 unit 42C
-- A/B Y-II AS-i 3RK2200-0DQ00-0AA3 1 1 unit 42C
-- A/B Y-II Uaux 3RK2200-1DQ00-1AA3 1 1 unit 42C
4 inputs/ 2A Standard Y-II AS-i 3RK1400-1DQ00-0AA3 1 1 unit 42C
4 outputs 2A Standard Standard AS-i 3RK1400-1CQ00-0AA3 1 1 unit 42C
1A Standard Y-II AS-i 3RK1400-1DQ01-0AA3 1 1 unit 42C
1A Standard Standard AS-i 3RK1400-1DQ03-0AA3 1 1 unit 42C
2A A/B (spec. V3.0) Y-II AS-i 3RK2400-1DQ00-0AA3 1 1 unit 42C
2A A/B (spec. V3.0) Y-II Uaux 3RK2400-1DQ00-1AA3 1 1 unit 42C
4 inputs/ 2A A/B Y-II AS-i 3RK2400-1FQ03-0AA3 1 1 unit 42C
3 outputs
4 inputs/ 2A Standard Y-II AS-i 3RK1400-1MQ00-0AA3 1 1 unit 42C
2 outputs
4 inputs -- Standard Y-II AS-i 3RK1200-0CQ00-0AA3 1 1 unit 42C
-- A/B Y-II AS-i 3RK2200-0CQ00-0AA3 1 1 unit 42C
2 x 2 inputs/ 1A Standard Y AS-i 3RK1400-1DQ02-0AA3 1 1 unit 42C
2 x 2 outputs
4 outputs 2A Standard Y-II -- 3RK1100-1CQ00-0AA3 1 1 unit 42C
2A A/B (spec. V3.0) Y-II -- 3RK2100-1CQ00-0AA3 1 1 unit 42C
Digital I/O modules, IP67 - K60 data couplers
Modules supplied without mounting plate
Type Current- Slave Pin Sensor
carrying addressing assign- power
capacity of type ment supply via
outputs
Data coupler -- Standard -- -- 3RK1408-8SQ00-0AA3 1 1 unit 42C
4 inputs/4
outputs (virtual)
1)
Module occupies two AS-Interface addresses For safety modules for AS-Interface, see page 2/27 onwards.

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

K60 mounting plates


Suitable for all K60 compact modules
• Wall mounting 3RK1901-0CA00 1 1 unit 42C
• DIN-rail mounting 3RK1901-0CB01 1 1 unit 42C

3RK1901-0CA00
AS-Interface sealing caps M12 3RK1901-1KA00 100 10 units 42C
For free M12 sockets

3RK1901-1KA00
Sealing sets 3RK1902-0AR00 100 5 units 42D
• For K60 mounting plate
• Cannot be used for K45 mounting plate
• One set contains one straight and one shaped seal
3RK1902-0AR00

* You can order this quantity or a multiple thereof.


2/46 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Digital I/O modules, IP68/IP69 - K60R

■ Overview
Operation in particularly harsh environments Connection

2
NSA0_00339f
K60R K60R K60R
IP68 IP68 IP68

Distributor

K60R module in degree of protection IP68/IP69 (IP69K)


Modules with degree of protection IP67 cannot be used in areas
exposed to permanently high levels of humidity, in applications
with drilling emulsions and cutting oils or when cleaning with IP67
high-pressure cleaners. The answer for these applications is
provided by the expansion of the K60 compact modules with the
K60R module with degree of protection IP68/IP69 (IP69K). K60R connection options

The K60R modules are connected instead of the AS-Interface In the IP67 environment, the service-proven standard
flat cable using a round cable with M12 cable box. The components are connected using flat cables. Spur lines are laid
AS-Interface bus cable and the 24 V DC auxiliary power into the IP68 environment by means of an AS-Interface M12
supply are routed in this case in a shared round cable. feeder (3RK1901-2NR..). The module is connected with a round
cable to an M12 cable box. For this purpose, the module has an
Degree of protection IP68 permits many new applications that M12 bus connection instead of the former addressing socket.
were impossible with the former field modules with degree of The AS-Interface bus cable and the 24 V DC auxiliary voltage
protection IP67. In applications such as filling plants or machine are routed together in a 4-pole round cable. There must be no
tools, the K60R with degree of protection IP68 enables the ground conductor in this round cable. Connection to ground is
module to be used directly in zones exposed to permanent made through the mounting plate.
loading by humidity. It is thus possible to make even more
rigorous savings in wiring with AS-Interface. For more In the IP68 environment, only cables with extruded M12 plugs
information on IP68 test conditions, see "IP68/IP69 (IP69K) may be used.
tests", page 2/48. Please note the following conditions:
Cleaning with high-pressure cleaners, such as is regularly • The configuration guidelines for AS-Interface apply.
required in the food and beverages industry for instance, For all M12 connecting cables, the maximum permissible
is possible without difficulty (IP69). current is limited to 4 A. The cross-section of these cables
is just 0.34 mm². For connection of the K60R modules,
In applications with cable carriers, many users rely on placing the aforementioned M12 connecting cables can be used
the AS-Interface bus cable in a round cable. With the K60R for the spur lines. The voltage drop caused by the ohmic
module, a round cable connection enables direct connection resistance (approx. 0.11 /m) must be taken into account.
to a round cable. No adapter is required.
• For round cable connections with shared AS-i and Uaux in
Mounting a single cable, the following maximum lengths apply:
- Per spur line from feeder to module: max. 5 m
The same mounting plates are used as for the K60 modules. - Total of all round cable segments in an AS-Interface network:
Instead of using flat cables, the K60R is connected using max. 20 m
a 4-pole round cable with an M12 connection. With the K60R the
mounting plate thus serves only as a fixture and ground terminal.
Addressing
Addressing is performed using the same socket as for the bus
connection. Connecting the module to the addressing unit takes
place over a 3-pole standard M12 cable.
When the mounting is finished, the module is connected with
the addressing cable to the addressing unit and addressed.
The addressing cable is then removed and the module
connected to the bus cable.

Siemens IC 10 · 2023 2/47


© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Digital I/O modules, IP68/IP69 - K60R
IP68/IP69 (IP69K) tests To simulate requirements as realistically as possible,
the modules were artificially aged prior to the tests by
K60R modules were tested with the following tests: 15 temperature cycles of -25/+85 °C. During the test,
• Stricter test than IP67: 90 min at 1.8 m depth of water the modules were connected to 3RX1 connecting cables.
(IP67: 30 min at 1 m depth of water) Unassigned connections were closed with 3RK1901-1KA00
2

• Salt water test: Five months in salt water, 20 cm deep, at room sealing caps.
temperature Note:
• Test with particularly creepable oil: Five months completely
under oil at room temperature Sealing caps and M12 connections must be tightened with
the correct torque.
• Test with drilling emulsion: Five months at room temperature
(components of the drilling emulsion: Anionic and non-ionic
emulsifiers, paraffinic low-aromatic mineral oil, boric acid
alkanolamines, corrosion inhibitors, oil content 40%)
• Test in oil bath (Excellence 416 oil) with alternating oil bath
temperature: 130 cycles of 15 to 55 °C, two months
• Cleaning with a high-pressure cleaner according to IP69
(IP69K): 80 to 100 bar, 10 to 15 cm distance, time per side
> 30 s, water temperature 80 °C

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Digital I/O modules, IP68/IP69 - K60R 3RK1400-1CR00-0AA3 1 1 unit 42C


• 4 inputs/4 outputs
• Width 60 mm
• IP68/IP69 (IP69K)
• Standard assignment
• Current-carrying capacity
- 200 mA (inputs)
- 2 A (outputs)
3RK1400-1CR00- • Slave addressing type: Standard address
0AA3
• Modules supplied without mounting plate

* You can order this quantity or a multiple thereof.


2/48 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Digital I/O modules, IP68/IP69 - K60R

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

2
K60 mounting plates
Suitable for all K60 and K60R compact modules
• Wall mounting 3RK1901-0CA00 1 1 unit 42C
• DIN-rail mounting 3RK1901-0CB01 1 1 unit 42C

3RK1901-0CA00
AS-Interface sealing caps M12 3RK1901-1KA00 100 10 units 42C
For free M12 sockets

3RK1901-1KA00
AS-Interface M12 feeders, current-carrying capacity up
to 4 A
For flat For Cable Cable end in
cable length feeder
AS-i/Uaux M12 socket -- Not available 3RK1901-2NR20 1 1 unit 42C
AS-i/Uaux M12 cable box 1m Not available 3RK1901-2NR21 1 1 unit 42C
AS-i/Uaux M12 cable box 2m Not available 3RK1901-2NR22 1 1 unit 42C

3RK1901-2NR21
AS-Interface M12 feeders, 4-fold, current-carrying
capacity up to 4 A
For flat For Cable Cable end in
cable length feeder
AS-i/Uaux 4-fold M12 socket, -- Not available 3RK1901-1NR04 1 1 unit 42C
delivery includes
mounting plate (for
wall and DIN-rail
mounting)
3RK1901-1NR04
M12 connecting cables 3RK1902-4PB15-3AA0 1 1 unit 42D
• 3-pole
3RK1902-4PB15-3AA0
• For addressing AS-i slaves with M12 bus connection
• Cable length 1.5 m

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/49
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Digital I/O modules, IP67 - K45

■ Overview
Connection of the AS-Interface shaped cables
The mounting plate and the compact module are joined together
2

by means of a screw, with simultaneous contacting of the


AS-Interface cable by the service-proven insulation piercing
method.
Now, mounting the AS-Interface shaped cables is in fact easier
than ever. The yellow and black AS-Interface shaped cable can
be inserted into the mounting plates from the left or right
regardless of the position of the coding lug. The correct polarity
of the applied voltages is thus guaranteed.
Addressing and connection of the sensors/actuators
Addressing of the K45 compact modules is performed using an
addressing socket integrated in the module. The addresses can
be assigned even when mounted.
Compact modules K45 K45 modules with a maximum of four digital inputs and outputs
The K45 series of compact modules supplements the large K60 These compact modules contain up to four M12 standard
compact modules which have a proven track record in industry. connections or M8 standard connections for inputs and outputs.
They are the logical consequence for rounding off the bottom Using M12 or M8 standard plugs, a maximum of four sensors
end of the existing product range. and four actuators can be connected to the compact module.
The acclaimed advantages of the existing K60 compact Depending on the module, the sockets can be assigned
modules are fully emulated by the K45 modules. The K45 in duplicate.
modules have a substantially smaller basic area and installation Pin assignment: Y –i.e. via a socket, two sensors or one
depth, however. sensor/one actuator are connected.
Yet in spite of these small dimensions all the modules have large K45 modules with a maximum of eight digital inputs
labels and an integrated addressing socket. These modules have eight digital inputs for connection
Two mounting plates are offered for the K45 compact modules: through M12 plugs. The sockets have duplicate assignments.
Pin assignment: Y –i.e. via a socket, two sensors or one
• Mounting plate for wall mounting sensor/one actuator are connected.
This has a hole pattern that is identical to that of the K60
compact modules. This means that K60 compact modules The module requires two AS-Interface addresses for processing
can be mounted together with K45 modules in an aligned all eight inputs. The addresses can be assigned through
arrangement. The shaped cables can be inserted in the a double addressing socket integrated in the module.
recesses of the mounting plates where they cause no
hindrance.
• Mounting plate for DIN-rail mounting

2/50 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Digital I/O modules, IP67 - K45

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

2
Digital I/O modules, IP67 - K45
• PNP transistor
• Width 45 mm
• Current-carrying capacity of the inputs: 200 mA
• Modules supplied without mounting plate
Type Current- Slave Pin Uaux Connection
carrying addressing assign- 24 V methods
capacity type ment
of outputs
8 inputs1) -- A/B Y -- M12 3RK2200-0DQ20-0AA3 1 1 unit 42C
3RK1400- 4 inputs -- Standard Standard -- M12 3RK1200-0CQ20-0AA3 1 1 unit 42C
0GQ20-0AA3
-- Standard Standard -- M8 3RK1200-0CT20-0AA3 1 1 unit 42C
-- A/B Standard -- M12 3RK2200-0CQ20-0AA3 1 1 unit 42C
-- A/B Standard -- M8 3RK2200-0CT20-0AA3 1 1 unit 42C
2 x 2 inputs -- A/B Y -- M12 3RK2200-0CQ22-0AA3 1 1 unit 42C
2 inputs/ 2 A2) Standard Standard ✓ M12 3RK1400-1BQ20-0AA3 1 1 unit 42C
2 outputs
2 x (1 input/ 0.2 A Standard Y -- M12 3RK1400-0GQ20-0AA3 1 1 unit 42C
1 output)
4 x (1 input/ 0.2 A A/B Y -- M12 3RK2400-0GQ20-0AA3 1 1 unit 42C
1 output) (spec. V3.0)
0.5 A A/B Y ✓ M12 3RK2400-1GQ20-1AA3 1 1 unit 42C
(spec. V3.0)
4 outputs 1A A/B Standard ✓ M12 3RK2100-1CQ20-0AA3 1 1 unit 42C
(spec. V3.0)
3 outputs 1A A/B Standard ✓ M12 3RK2100-1EQ20-0AA3 1 1 unit 42C
4 outputs 1A Standard Standard ✓ M12 3RK1100-1CQ20-0AA3 1 1 unit 42C
2 outputs/ 2A A/B Standard ✓ M12 3RK2400-1BQ20-0AA3 1 1 unit 42C
2 inputs
✓ Available 1) Module occupies two AS-Interface addresses
2)
-- Not available The typical current-carrying capacity per output increases with version
"E12" from 1.5 to 2 A (available since approx. 07/2003).
For safety modules for AS-Interface, see page 2/27 onwards.

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

K45 mounting plates


• For wall mounting 3RK1901-2EA00 1 1 unit 42C
• For DIN-rail mounting 3RK1901-2DA00 1 1 unit 42C

3RK1901-2EA00
Cable end terminator 3RK1901-1MN00 1 10 units 42C
For sealing open cable ends of the
AS-Interface shaped cable with IP67

3RK1901-1MN00
AS-Interface sealing caps
• For free M12 sockets 3RK1901-1KA00 100 10 units 42C
• For free M8 sockets 3RK1901-1PN00 100 10 units 42C

3RK1901-1KA00

3RK1901-1PN00

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/51
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Digital I/O modules, IP67 - K20

■ Overview
Robotics is yet another application area. The K20 modules are
connected to the AS-Interface with a round cable with M12 cable
box instead of with the AS-Interface flat cable. The AS-Interface
2

bus cable and the 24 V DC auxiliary energy are routed in this


case in a shared round cable. This enables extremely compact
installation.
The flexibility of the round cable means that it can also be used
on moving machine parts without any problems. The K20
modules are also ideal for such applications as their non-
encapsulated design makes them particularly light in weight.
In applications with cable carriers, many users rely on placing
the AS-Interface bus cable in a round cable. In this case, the K20
modules support direct connection to the round cable. No flat to
round cable adapter is required.
The K20 compact module range includes standard AS-Interface
modules, as well as an ASIsafe version for the connection of
safety-related sensors, such as EMERGENCY STOP
Digital I/O modules, IP67 - K20 pushbuttons or protective door monitoring.
The K20 compact module series rounds off the AS-Interface For particularly space-saving dimensions, the sensors
compact modules with a particularly slim design and only and actuators are connected over M8 plug-in connectors.
20-mm width. Thanks to its extremely compact dimensions, Alternatively, M12 connectors with Y-assignment can be used.
these modules are particularly suited for handling machine
applications in the field of production engineering where
modules need to be arranged in the smallest of spaces.

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Digital I/O modules, IP67 - K20


Width 20 mm
Type Current- Slave Pin Connection
carrying addressing assignment methods
capacity type
of outputs
4 inputs -- A/B Standard M8 3RK2200-0CT30-0AA3 1 1 unit 42C
-- A/B Y M12 3RK2200-0CQ30-0AA3 1 1 unit 42C
2 inputs/ 1 A/B Standard M8 3RK2400-1BT30-0AA3 1 1 unit 42C
2 outputs 1 A/B Y M12 3RK2400-1BQ30-0AA3 1 1 unit 42C
3RK2200-
0CT30-0AA3 4 outputs 1 A/B (spec. V3.0) Standard M8 3RK2100-1CT30-0AA3 1 1 unit 42C
4 inputs/ 1 Standard Standard M8 3RK1400-1CT30-0AA3 1 1 unit 42C
4 outputs 1 A/B (spec. V3.0) Standard M8 3RK2400-1CT30-0AA3 1 1 unit 42C
2 safe -- Standard Y-II M12 3RK1205-0BQ30-0AA3 1 1 unit 42C
inputs

For safety modules for AS-Interface, see page 2/27 onwards.

* You can order this quantity or a multiple thereof.


2/52 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Digital I/O modules, IP67 - K20

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

2
AS-Interface sealing caps
• For free M12 sockets 3RK1901-1KA00 100 10 units 42C
• For free M8 sockets 3RK1901-1PN00 100 10 units 42C

3RK1901-1KA00

3RK1901-1PN00
AS-Interface compact distributors, 1 1 unit 42C
for AS-Interface flat cable AS-i or Uaux
• Current-carrying capacity up to 8 A
3RK1901-2NN10 • Degree of protection IP67/IP68/IP69 (IP69K)
For flat For Cable Cable end in
cable length feeder
AS-i or Uaux Flat ribbon cable -- Not available 3RK1901-2NN10 1 1 unit 42C
AS-i or Uaux
AS-Interface M12 feeders
• Current-carrying capacity up to 2 A
• Degree of protection IP67
3RX9801-0AA00 For flat For Cable Cable end in
cable length feeder
AS-i M12 socket -- Available 3RX9801-0AA00 1 1 unit 42C
AS-Interface M12 feeders
• Current-carrying capacity up to 4 A
• Degree of protection IP67/IP68/IP69 (IP69K)
For flat For Cable Cable end in
3RK1901-2NR10 cable length feeder
AS-i M12 socket -- Not available 3RK1901-2NR10 1 1 unit 42C
AS-i M12 cable box 1m Not available 3RK1901-2NR11 1 1 unit 42C
AS-i M12 cable box 2m Not available 3RK1901-2NR12 1 1 unit 42C
AS-i/Uaux M12 socket -- Not available 3RK1901-2NR20 1 1 unit 42C
AS-i/Uaux M12 cable box 1m Not available 3RK1901-2NR21 1 1 unit 42C
AS-i/Uaux M12 cable box 2m Not available 3RK1901-2NR22 1 1 unit 42C

3RK1901-2NR21
AS-Interface M12 feeders, 4-fold
• Current-carrying capacity up to 4 A
• Degree of protection IP67
For flat For Cable Cable end in
cable length feeder
AS-i/Uaux 4-fold M12 socket, -- Not available 3RK1901-1NR04 1 1 unit 42C
delivery includes
mounting plate
3RK1901-1NR04 (for wall and DIN-rail
mounting)
M12 Y-shaped coupler plugs 6ES7194-1KA01-0XA0 1 1 unit 250
For connection of two sensors to one M12 socket with
Y-assignment

6ES7194-1KA01-0XA0
M12 connecting cables 3RK1902-4PB15-3AA0 1 1 unit 42D
• 3-pole
3RK1902-4PB15-3AA0
• For addressing AS-i slaves with M12 bus connection
• Cable length 1.5 m

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/53
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Analog I/O modules, IP67 - K60

■ Overview ■ Benefits
• Analog modules are just as easy to integrate in AS-Interface
as digital modules
2

• Analog values can be easily detected and issued locally


• Preprocessing of the analog value transfer in the master
enables rapid evaluation of the analog values
• Up to four values can be detected using one analog module
• Faster transmission and conversion of analog values thanks to
the new option for switching to single-channel operation
In addition, specification V3.0 now also offers:
• A/B technology, now also with analog modules
• On average, double fast transmission times (only 3 or
4 cycles, depending on the resolution selected)
• Variable adjustable mode: 12-bit or 14-bit resolution,
1-channel or 2-channel, selectable via the ID1 code

K60 analog compact module

More information
Manual for AS-Interface analog modules, see
https://support.industry.siemens.com/cs/ww/en/view/7643815

AS-Interface analog modules from the K60 compact series


detect or issue analog signals locally. These modules are linked
to the higher-level controller through an AS-Interface master
according to specification V2.1 or specification V3.0.
The analog modules are divided into the following groups:
• Input modules for
- Current measurement
- Voltage measurement
- Thermal resistance measurement
• Output modules for
- Current actuators
- Voltage actuators
The input modules according to profile 7.3/7.4 are available with
two or four input channels. It is possible in addition to convert the
2-channel module to using only one input channel, thus enabling
very short times before the analog value is available. The
conversion is effected by means of a jumper plug at socket 3.
The transmission times achieved with analog modules
according to profile 7.A.9 are twice as fast as those achieved
with profile 7.3/7.4. Operation is adjustable in this case, e.g. it is
possible to choose with the ID1 code whether the module is
operated with 1 or 2 channels.
The output modules are configured as 2-channel modules
as standard.
The input and output channels are electrically separated
from the AS-Interface network. If sensors with a higher power
requirement are to be connected, more power can be supplied
through the auxiliary voltage as an alternative to the internal
supply.
In the manual (see "More information"), the modules are
presented in great detail along with their technical specifications
and in-depth notes on operation. Sample function blocks round
off the manual.

2/54 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Analog I/O modules, IP67 - K60

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,

2
SET, M)

Analog I/O modules, IP67 - K60,


analog profile 7.3
• Slave addressing type: Standard address
• Width 60 mm
• Modules supplied without mounting plate
Inputs Type Measuring range
1 or 2 inputs Current 4 ... 20 mA or 3RK1207-1BQ40-0AA3 1 1 unit 42C
(selectable using 20 mA
jumper plug at (selectable)1)
3RK1207-1BQ44-0AA3 socket 3) Voltage 10 V or 3RK1207-2BQ40-0AA3 1 1 unit 42C
1 ... 5 V
(selectable)
Thermal resistance Pt100 or 3RK1207-3BQ40-0AA3 1 1 unit 42C
Ni100 or
0 ... 600 
(selectable)1)
4 inputs Current 4 ... 20 mA or 3RK1207-1BQ44-0AA3 1 1 unit 42C
20 mA
(selectable)
Voltage 10 V or 3RK1207-2BQ44-0AA3 1 1 unit 42C
1 ... 5 V
(selectable)
Thermal resistance Pt100 or 3RK1207-3BQ44-0AA3 1 1 unit 42C
Ni100 or
0 ... 600 
(selectable)
Outputs Type Output range
2 outputs Current 4 ... 20 mA or 3RK1107-1BQ40-0AA3 1 1 unit 42C
for two-wire 20 mA or
actuators 0 ... 20 mA
(selectable)1)
Voltage 10 V or 3RK1107-2BQ40-0AA3 1 1 unit 42C
for two-wire 0 ... 10 V or
actuators 1 ... 5 V
(selectable)
Analog I/O modules, IP67 - K60,
analog profile 7.A.9
• Slave addressing type: A/B (spec. V3.0)
• Width 60 mm
• Modules supplied without mounting plate
Inputs Type Measuring range
1 or 2 inputs Current 4 ... 20 mA or 3RK2207-1BQ50-0AA3 1 1 unit 42C
(variably 20 mA
adjustable) (selectable)
3RK2207-2BQ50-0AA3 Voltage 10 V or 3RK2207-2BQ50-0AA3 1 1 unit 42C
1 ... 5 V
(selectable)
1)
Some modules are available in the extended temperature range
(from -25 to +70 °C) and for use in harsh environmental conditions
(coated according to environment standard IEC 60721).
Description SIPLUS article number Corresponds to module
SIPLUS AS-Interface 2AA, IP67 6AG1107-1BQ40-7AA3 3RK1107-1BQ40-0AA3
SIPLUS AS-Interface 2AI, IP67 6AG1207-1BQ40-7AA3 3RK1207-1BQ40-0AA3
SIPLUS AS-Interface 2AI, IP67 6AG1207-3BQ40-7AA3 3RK1207-3BQ40-0AA3
For more information, see www.siemens.com/siplus-extreme.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/55
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the field, high degree of protection > Analog I/O modules, IP67 - K60

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)
2

K60 mounting plates


• Wall mounting 3RK1901-0CA00 1 1 unit 42C
• DIN-rail mounting 3RK1901-0CB01 1 1 unit 42C

3RK1901-0CA00
M12 sealing caps 3RK1901-1KA00 100 10 units 42C

3RK1901-1KA00
Sealing sets 3RK1902-0AR00 100 5 units 42D
• For K60 mounting plate
• Cannot be used for K45 mounting plate
• One set contains one straight and one shaped seal
3RK1902-0AR00
Jumper plugs 3RK1901-1AA00 1 1 unit 42C
For changing over the 2-channel input modules
3RK1901-1AA00

* You can order this quantity or a multiple thereof.


2/56 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the control cabinet > Introduction

■ Overview
For AS-Interface applications inside control cabinets, there are
various module series for the most diverse requirements:

2
• SlimLine Compact – particularly slim design ideal for space-
saving use in the control cabinet
• F90 module – particularly flat design for flat control boxes
• Flat module – special design for integration into customer-
specific solutions
The existing SlimLine series of modules S22.5 and S45 are being
replaced by the innovative new devices in the SlimLine Compact
SC17.5, SC17.5F and SC22.5 series. The previous SlimLine
modules are still available as replacements for existing systems.
Available versions
The following table provides an overview of the key features of
the different series of control cabinet modules.
Feature SlimLine Compact F90 Flat module
SlimLine Compact modules SC17.5F, SC17.5 and SC22.5 module
Digital I/O ✓ ✓ ✓
Analog I/O ✓ -- --
Safe inputs ✓ -- --
Relay outputs ✓ -- --
Addressing type ✓ -- --
A/B address
Mounting on TH 35 DIN ✓ ✓ --
rail according to
IEC 60715
Wall mounting using ✓ -- --
push-in lugs
Integrated lugs for screw -- -- ✓
fixing
Width in mm 17.5 or 22.5 90 80
✓ Available
-- Not available

F90 module

Flat module

Siemens IC 10 · 2023 2/57


© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the control cabinet > SlimLine Compact

■ Overview
SlimLine Compact modules
2

SC17.5 and SC22.5 SlimLine Compact modules with screw terminals SC22.5 SlimLine Compact module with connector with screw terminals

The AS-Interface module series for the control cabinet SlimLine All devices for the connection of three-wire sensors offer the
Compact with degree of protection IP20 creates space in the option of supplying the sensors either from the AS-Interface bus
cabinet and in distributed local control boxes. A width of just cable or alternatively from the 24 V DC voltage supply Uaux
17.5 mm or 22.5 mm ensures considerable space savings in the depending on the requirements of the particular application.
control cabinet. A slide switch is used to make the selection. If supply via Uaux is
selected, the wiring of the sensor terminals remains unchanged.
The SlimLine Compact module series comprises not only digital This means that no external supply is required for the sensors.
and analog I/O modules but also ASIsafe modules with safe
inputs. Digital outputs are available as solid-state and relay All modules have LEDs on the front that provide diagnostics
outputs. information and indicate the status of the module inputs and
outputs. Devices with semiconductor outputs indicate the status
Sensors and actuators, as well as the AS-Interface bus cable, of each output by means of a dual LED. Thus the status
are connected by means of removable screw or push-in spring- (on/off/overload) is displayed for each output. An addressing
loaded terminals. Device connectors available as accessories socket integrated at the front enables the module to be
offer the possibility of looping through the AS-Interface bus addressed also when it is installed. Integrated adapters permit
cable and the 24 V DC power supply Uaux from one module to mounting on a DIN rail  either directly for the module or for the
additional modules. This significantly simplifies the wiring, as the device connector. Alternatively, the modules can also be screw-
AS-Interface bus cable and Uaux only have to be connected to mounted using push-in lugs (accessories). These lugs for screw
one device. fastening must be ordered separately.

2/58 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the control cabinet > SlimLine Compact

■ Selection and ordering data


PU (UNIT, SET, M) = 1
PS* = 1 unit More information
PG = 42C

2
Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/109481489

For multi-unit Version Screw terminals Spring-loaded


packaging, I/O type Width Inputs Outputs terminals (push-in)
see page 16/7.
Article No. Price Article No. Price
mm per PU per PU
SC17.5 and SC22.5 digital SlimLine Compact modules
Slave addressing type: A/B address
4 inputs 17.5 Two-wire -- 3RK2200-0CE00-2AA2 3RK2200-0CG00-2AA2

22.5 Three-wire -- 3RK2200-2CE00-2AA2 3RK2200-2CG00-2AA2

4 outputs 22.5 -- 2A 3RK2100-1CE00-2AA2 3RK2100-1CG00-2AA2


semiconductor
4 inputs/ 22.5 Three-wire Relay 3RK2402-2ME00-2AA2 3RK2402-2MG00-2AA2
3RK2200-0CG00-2AA2
2 outputs, (change-over
relays contact)
4 inputs/ 22.5 Three-wire Relay 3RK2402-2CE00-2AA2 3RK2402-2CG00-2AA2
4 outputs, (NO contacts)
relays
4 inputs/ 22.5 Three-wire 2A 3RK2400-2CE00-2AA2 3RK2400-2CG00-2AA2
4 outputs semiconductor
Slave addressing type: Standard
3RK2400-2CG00-2AA2 address
4 inputs/ 22.5 Three-wire 2A 3RK1400-2CE00-2AA2 3RK1400-2CG00-2AA2
4 outputs semiconductor
SC22.5 analog SlimLine Compact modules
Slave addressing type: Standard
address
4 inputs 22.5 Voltage/ -- 3RK1207-0CE00-2AA2 3RK1207-0CG00-2AA2
current
selectable
(1 ... 5 V,
10 V,
4 ... 20 mA,
3RK1207-0CG00-2AA2 20 mA)
Thermal -- 3RK1207-3CE00-2AA2 3RK1207-3CG00-2AA2
resistance
(Pt100,
Ni100,
0 ... 600 )
2 outputs 22.5 -- Voltage/ 3RK1107-0BE00-2AA2 3RK1107-0BG00-2AA2
current
selectable
(0 ... 10 V,
1 ... 5 V,
10 V,
0 ... 20 mA,
4 ... 20 mA,
20 mA)
SC17.5F ASIsafe SlimLine Compact modules
Slave addressing type: Standard
address
2 safe 17.5 For -- 3RK1205-0BE00-2AA2 3RK1205-0BG00-2AA2
inputs mechanical
contacts
2 safe 17.5 For Semiconductor 3RK1405-2BE00-2AA2 3RK1405-2BG00-2AA2
inputs/ mechanical UASI/Uaux
2 standard contacts supply
3RK1405-2BE00-2AA2 outputs selectable

For safety modules for AS-Interface, see page 2/27 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/59
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the control cabinet > SlimLine Compact

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)
2

Device connectors
For electrical connection of SlimLine Compact modules
(connects AS-i bus cable and 24 V DC auxiliary power supply
Uaux when using several SlimLine Compact modules)
• Width 17.5 mm 3RK1901-1YA00 1 1 unit 42C
• Width 22.5 mm 3RK1901-1YA10 1 1 unit 42C

3RK1901- 3RK1901-
1YA00 1YA10
Device termination connectors
Required for the last module in the network
• Width 17.5 mm 3RK1901-1YA01 1 1 unit 42C
• Width 22.5 mm 3RK1901-1YA11 1 1 unit 42C

3RK1901- 3RK1901-
1YA01 1YA11
Removable terminals Screw terminals

• Screw terminals up to 2 x 1.5 mm2 or 1 x 2.5 mm2


- 2-pole 3ZY1121-1BA00 1 6 units 41L
- 4-pole 3ZY1141-1BA00 1 6 units 41L
Spring-loaded
3ZY1121-2BA00 terminals (push-in)
• Push-in terminals up to 2 x 1.5 mm2
- 2-pole 3ZY1121-2BA00 1 6 units 41L
- 4-pole 3ZY1141-2BA00 1 6 units 41L
Hinged cover
Replacement for SlimLine Compact module,
without terminal labeling
• Width 17.5 mm
- Titanium gray for SC17.5 3ZY1450-1AA00 1 5 units 41L
- Yellow for SC17.5F 3ZY1450-1BA00 1 5 units 41L
• Width 22.5 mm
- Titanium gray for SC22.5 3ZY1450-1AB00 1 5 units 41L

3ZY1450- 3ZY1450-
1BA00 1AB00
Push-in lugs for wall mounting 3ZY1311-0AA00 1 10 units 41L
Two lugs are required per device

3ZY1311-0AA00
Coding pins for removable terminals 3ZY1440-1AA00 1 12 units 41L
For mechanical coding of the terminals

3ZY1440-1AA00
Blank labels
Unit labeling plates1)
• 10 mm x 7 mm, titanium gray 3RT2900-1SB10 100 816 41B
units
IC01_00181

• 20 mm x 7 mm, titanium gray 3RT2900-1SB20 100 340 41B


units
3RT2900-1SB20
Tools for opening spring-loaded terminals Spring-loaded
terminals
Screwdriver for SIRIUS devices with spring-loaded terminals 3RA2908-1A 1 1 unit 41B
3.0 mm x 0.5 mm, length approx. 200 mm,
3RA2908-1A titanium gray/black, partially insulated
1) PC labeling system for individual inscription of unit labeling
plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


2/60 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the control cabinet > SlimLine Compact

■ More information
The existing SlimLine series of I/O modules for use in the control
cabinet is being replaced by the new, innovative SlimLine
Compact series. We recommend that these new devices are

2
used in future.
The code conversion table indicates the best options for replacing
the existing SlimLine devices with SlimLine Compact devices.
Note:
The previous SlimLine devices are still available for use as
replacements in existing systems. As a result of the innovation,
the new SlimLine Compact devices are not fully compatible in
terms of either mechanical dimensions or electrical properties.
The code conversion table below links the existing S22.5,
S22.5F and S45 SlimLine modules with the new SC17.5,
SC17.5F and SC22.5 SlimLine Compact devices.

SlimLine S45 modules (picture on left) and S22.5 module


(picture on right) with spring-loaded terminals
Code conversion table
S22.5, S22.5F and S45 SlimLine Comparison type: SC17.5, SC17.5F and SC22.5 SlimLine Compact
Screw terminals Spring-loaded terminals Version Screw terminals Spring-loaded terminals Version
3RK1200-0CE00-0AA2 3RK1200-0CG00-0AA2 4 DI, two-wire, 3RK2200-0CE00-2AA2 3RK2200-0CG00-2AA2 4 DI, two-wire,
standard address A/B address
3RK2200-0CE02-0AA2 3RK2200-0CG02-0AA2 4 DI, 3RK2200-2CE00-2AA2 3RK2200-2CG00-2AA2 4 DI,
A/B address A/B address
3RK1200-0CE02-0AA2 3RK1200-0CG02-0AA2 4 DI,
standard address
3RK1400-0BE00-0AA2 3RK1400-0BG00-0AA2 2 DI/2 DQ, 3RK1400-2CE00-2AA2 3RK1400-2CG00-2AA2 4 DI/4 DQ,
standard address standard address
3RK1402-0BE00-0AA2 3RK1402-0BG00-0AA2 2 DI/2 DQ relay, 3RK2402-2ME00-2AA2 3RK2402-2MG00-2AA2 4 DI/2 DQ relay,
standard address A/B address
3RK1100-1CE00-0AA2 3RK1100-1CG00-0AA2 4 DQ, 3RK2100-1CE00-2AA2 3RK2100-1CG00-2AA2 4 DQ,
standard address A/B address
3RK2400-1CE01-0AA2 3RK2400-1CG01-0AA2 4 DI/4 DQ, 3RK2400-2CE00-2AA2 3RK2400-2CG00-2AA2 4 DI/4 DQ,
A/B address A/B address
3RK2400-1FE00-0AA2 3RK2400-1FG00-0AA2 4 DI/3 DQ,
A/B address
3RK1400-1CE00-0AA2 3RK1400-1CG00-0AA2 4 DI/4 DQ, 1A semiconductor, 3RK1400-2CE00-2AA2 3RK1400-2CG00-2AA2 4 DI/4 DQ, 2A
standard address semiconductor,
3RK1400-1CE01-0AA2 3RK1400-1CG01-0AA2 4 DI/4 DQ, 2A semiconductor, standard address
standard address
3RK1402-3CE01-0AA2 3RK1402-3CG01-0AA2 4 DI/4 DQ
(sensor supply from Uaux),
standard address
3RK1402-3CE00-0AA2 3RK1402-3CG00-0AA2 4 DI/4 DQ relay, 3RK2402-2CE00-2AA2 3RK2402-2CG00-2AA2 4 DI/4 DQ relay,
standard address A/B address
3RK1205-0BE00-0AA2 3RK1205-0BG00-0AA2 2 F-DI, 3RK1205-0BE00-2AA2 3RK1205-0BG00-2AA2 2 F-DI,
standard address standard address
3RK1405-0BE00-0AA2 3RK1405-0BG00-0AA2 2 F-DI/2 DQ, 3RK1405-2BE00-2AA2 3RK1405-2BG00-2AA2 2 F-DI/2 DQ,
standard address standard address
(outputs supplied from UASI) (supply UASI/Uaux
3RK1405-1BE00-0AA2 3RK1405-1BG00-0AA2 2 F-DI/2 DQ, selectable)
standard address
(outputs supplied from Uaux)

Siemens IC 10 · 2023 2/61


© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the control cabinet > F90 module

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)
2

F90 module
• Slave addressing type: Standard address
• Width 90 mm
• With COMBICON version:
Delivery without COMBICON plug
Type Connection Inputs Outputs
4 Screw Two and PNP transistor 3RG9002-0DB00 1 1 unit 42C
3RG9002-0DB00 inputs/ three-wire 1A
4 PNP transistor
outputs Two and PNP transistor 3RG9002-0DA00 1 1 unit 42C
three-wire 2A
PNP transistor
Two and PNP transistor 3RG9002-0DC00 1 1 unit 42C
three-wire 2A
PNP transistor
floating
COMBICON1) Two and PNP transistor 3RG9004-0DB00 1 1 unit 42C
three-wire 1A
PNP transistor
Two and PNP transistor 3RG9004-0DA00 1 1 unit 42C
three-wire 2A
PNP transistor
Two and PNP transistor 3RG9004-0DC00 1 1 unit 42C
three-wire 2A
PNP transistor
floating
1)
Scope of supply does not include COMBICON connector set
3RX9810-0AA00, this must be ordered separately, see "Accessories".

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

COMBICON connector sets 3RX9810-0AA00 1 1 unit 42C


For 4I/4O modules with COMBICON connection;
one set comprises:
• 4 x 5-pole plug for connection
• Standard sensors/actuators
• 2 x 4-pole plug for AS-Interface and external auxiliary voltage

* You can order this quantity or a multiple thereof.


2/62 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Slaves
I/O modules for use in the control cabinet > Flat module

■ Overview
The flat module for the control cabinet in degree of protection
IP20 has four inputs and four outputs.

2
The module is fitted at the front with an LED which indicates the
module's status.
With the integrated lugs, the modules can be screwed on.
An integrated addressing socket enables the module to be
addressed when it is installed.
Standard sensors/actuators and the AS-Interface cable can be
connected using screw terminals.

Flat module 4I/4O

■ Selection and ordering data


Version Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price
per PU
Flat module 4I/4O 3RK1400-0CE00-0AA3 1 1 unit 42C
Slave addressing type: Standard address
• 4 inputs/4 outputs
• 200 mA for all I/Os

3RK1400-0CE00-0AA3

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/63
© Siemens 2023

Industrial communication
AS-Interface
Slaves
Modules with special functions > Counter modules

■ Overview
This results in a maximum frequency of fZmax = 1/1.3 ms = 769 Hz
independently of the control system (see figure below).
2

U IN1

NSA0_00084

≥ 1 ms ≥ 300 s t

Maximum frequency for the counter module


If the time criterion stipulated in the figure is violated, the count
value is rejected.
The counter is active only for the reset parameter P2 (default).
The counter is deleted when P2 is set, and the incoming count
Counter module with spring-loaded terminals pulses are not registered until after P2 is reset again.
The counter module is used to send hexadecimally coded Note:
count values (LSB=D0, MSB=D3) to a higher-level controller.
The count value is increased by 1 for each valid count pulse at A customized function block is necessary or must be
terminal 8. Beginning at 0, the module counts up to 15 and then programmed.
begins again at 0. The controller adopts the current value and
determines the number of pulses between two host invocations
ASi+ ASi-
through subtraction from the previous value. The total number of
count pulses is determined by adding these differences.
Terminal 4: Bus connection ASi +
For the values sent to be unambiguous, no more than 15 count ASi
Terminal 5: Bus connection ASi -
values are allowed between two host invocations or AS-Interface ADDR
Terminal 6: Unused
master invocations at terminal 8. The maximum permissible
transmission frequency is calculated from these times:
fTrmax = 15/Tmax
Tmax: max. possible transmission time from the slave to the host IN1

A further condition for the maximum frequency is the required Terminal 7: Sensor supply +
pulse shape. For the counter to accept a pulse as valid, a Low Terminal 8: Counter input
must have been applied at the input for at least 300 µs and Terminal 9: Sensor supply -
NSA0_00085

a High for at least 1 ms.


+ IN1 -

Counter module connection options

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Counter modules
Slave addressing type: Standard address
Width 22.5 mm
• With screw terminals 3RK1200-0CE03-0AA2 1 1 unit 42C

• With spring-loaded terminals 3RK1200-0CG03-0AA2 1 1 unit 42C

3RK1200-0CG03-0AA2

* You can order this quantity or a multiple thereof.


2/64 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Slaves
Modules with special functions > Ground-fault detection modules

■ Overview
"Ground faults in any control circuit must not lead to unintentional
starting or potentially hazardous movements or prevent the
machine from stopping." (IEC 60204-1/VDE 0113-1).

2
The AS-Interface ground-fault detection module is used to meet
these requirements. Using this module from the SlimLine series,
ground faults in AS-Interface systems can be reliably detected
and reported.
The following ground faults are detected:
• Ground fault from AS-i "+" to ground
• Ground fault from AS-i "-" to ground
• Ground fault on sensors and actuators that are supplied from
the AS-Interface voltage.
Note:
Not suitable for AS-i Power24V.
Check whether the AS-i power supply unit or the AS-i master
module, etc. features integrated ground-fault detection, and
Ground-fault detection module with spring-loaded terminals therefore whether a separate ground fault detection module can
be omitted.
It should be noted that an AS-i cable segment behind an
AS-i repeater requires its own ground-fault monitoring.

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Ground-fault detection modules


Module does not require an AS-i address
Width 22.5 mm
• With screw terminals 3RK1408-8KE00-0AA2 1 1 unit 42C

• With spring-loaded terminals 3RK1408-8KG00-0AA2 1 1 unit 42C

3RK1408-8KG00-0AA2

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/65
© Siemens 2023

Industrial communication
AS-Interface
Slaves
Modules with special functions > Overvoltage protection modules

■ Overview
With the AS-Interface overvoltage protection module, it is now
also possible to integrate AS-Interface in the overall overvoltage
protection concept of a plant or machine.
2

The module has the same design and degree of protection (IP67)
as the AS-Interface K45 compact modules. It is a passive module
and as such does not need its own address on the AS-Interface
network. The module can be used to protect the AS-Interface cable
and the cable for the auxiliary voltage from overvoltage.
Overvoltages are discharged through a ground cable with a green/
yellow oil-proof outer sheath. This cable is fixed in the module and
must be connected with low resistance to the system's ground.
Rated discharge current Isn
The rated discharge current is the peak value of a surge current
of the form 8/20 s (microseconds), for which the protection
AS-Interface overvoltage protection module module is designed in accordance with a specified test
program. With an 8/20 waveform, 100% of the value is achieved
The AS-Interface overvoltage protection module (protection after 8s and 50% after 20 s.
module) protects downstream AS-Interface devices or individual
sections in AS-i networks from conducted overvoltages which can Protection level Up
be caused by switching operations and remote lightning strikes.
The protection level of a protection module is the highest
The location of the protection module forms the transition from
momentary value of the voltage at the terminals, established in
zone 1 to 2/3 within the lightning protection zone concept. Direct
individual tests and characterizes the capability of a protection
lightning strikes must be coped with using additional protective
module to limit overvoltages to a residual level.
measures at the transitions from lightning protection zone 0A to 1.
Configuration guidelines

AS- AS- NSA0_00093a


OVP Inter- Inter-
face face

Device without ground terminal


Application Application → Grounding of the mounting plate

Device with Mounting plate


ground terminal

OVP = Overvoltage protection

The grounding of protection modules and the units to be If insulated devices are protected, their mounts must be
protected must be effected through a shared grounding point. included in the grounding points.
Sample application

Zone 1 Zone 2 Zone 1

AS- AS- AS- AS-


OVP Inter- Inter- Inter- Inter- OVP
face face face face
A B

Protected range

NSA0_00092b
Equipotential bonding
(system earth)
Protection approx. 0.5 m to the left
Protection approx. 5 m to the right OVP = Overvoltage protection

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

AS-Interface overvoltage protection module 3RK1901-1GA01 1 1 unit 42C


Module does not require an AS-i address
Delivery includes mounting plate
(for wall and DIN-rail mounting)

* You can order this quantity or a multiple thereof.


2/66 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Power supply units and data decoupling modules
AS-Interface power supply units

■ Overview
Dimensions
AS-Interface power supply units have compact dimensions in

2
widths of 50/70/120 mm. No distances from other devices need
to be observed when mounting the power supply units.
Features
• Higher rating: The power supply units deliver currents
of 2.6 to 8 A.
• Integrated data decoupling: As the result, AS-Interface is able
to convey both data and power along a single line.
• Integrated ground-fault detection: The power supply units
perform the reliable detection and signaling of ground faults
according to IEC 60204-1. The AS-Interface voltage can be
disconnected automatically in the event of a ground fault.
• Integrated overload detection: An output overload is detected
and reported over a diagnostics LED.
• Diagnostics memory: Any ground faults or overloads on the
output side are stored in a diagnostics memory and signaled
AS-Interface power supply unit for 3 A
until the device is RESET.
More information • Remote RESET and remote signaling: Using relay contacts,
Operating Instructions for AS-i power supply units, see a ground fault can be signaled and evaluated by a central
https://support.industry.siemens.com/cs/ww/en/view/21489904 and controller and/or indicator light.
https://support.industry.siemens.com/cs/ww/en/view/22317836 • Diagnostics LEDs: Three different LEDs indicate the status
AS-Interface power supply units feed 30 V DC into the of the AS-Interface power supply unit locally at the power
AS-Interface cable and supply the AS-Interface components. supply unit.
They include power-optimized data decoupling for the • Ultra-wide input range/2-phase connection: The ultra-wide
separation of communication signals and supply voltage. As the input range of 120 to 500 V of the 8 A version means that the
result, AS-Interface is able to convey both data and power along supply units can be used in virtually any network worldwide.
a single line. The power supply units are resistant to overload In addition, this version dispenses with the need for an
and short circuits. N conductor as the device can be connected directly
between 2 phases of a network.
• Operation with 24 V DC: The 3 A power supply unit is also
available as a version with a 24 V DC input. This power supply
unit is suitable for use in battery-powered systems or in
systems with UPS (uninterruptible power supply).
• Removable terminal blocks with spring-loaded terminals:
For easy exchanging of devices, each power supply unit has
three removable terminal blocks: for the input side, for the
output side and for Signal/RESET connections.

■ Benefits
• Complete solution for supplying AS-Interface networks while • Fast fault detection and reduced downtimes thanks to
making full use of the maximum possible cable length per diagnostics memory, remote signaling and Remote RESET
AS-i segment • Reduced downtimes as the result of removable terminal
• Only AS-i masters and AS-i slaves need to be connected to blocks which enable the fast exchanging of devices
the AS-Interface cable in order to operate AS-Interface • Ultra-wide input range of the 8 A version permits 1-phase and
• Compact, space-saving dimensions 2-phase operation and removes the need for an N conductor
• Reliable power supply even for large numbers of AS-Interface • Can be used world-wide thanks to, for example, UL/CSA
modules with a high power requirement approval (UL 508)
• Integrated ground-fault and overload detection saves the • With the 2.6 A version, the output power is restricted to
need for additional components and enhances safety max. 100 W for use in Class 2 circuits in accordance with NEC
(National Electrical Code)

Siemens IC 10 · 2023 2/67


© Siemens 2023

Industrial communication
AS-Interface
Power supply units and data decoupling modules
AS-Interface power supply units

■ Selection and ordering data


Version Spring-loaded terminals PU PS* PG
(UNIT,
SET, M)
2

Article No. Price


per PU
AS-Interface power supply units, IP20
• AS-i single output 30 V DC
• Output voltage ES1 according to IEC 62368-1
• With integrated ground-fault detection
• Ambient temperature during operation -10 ... +70 °C
• 2.6 A version with output power restricted to max. 100 W
(for Class 2 circuits in accordance with NEC)
3RX9501-0BA00 • Dimensions:
Width: 50 mm (2.6 A/3 A), 70 mm (5 A), 120 mm (8 A);
Height: 125 mm;
Depth: 125 mm
Output current Input voltage
3A 120/230 V AC (selectable) 3RX9501-0BA00 1 1 unit 42C
5A 120/230 V AC (selectable) 3RX9502-0BA00 1 1 unit 42C
8A 120/230 ... 500 V AC 3RX9503-0BA00 1 1 unit 42C
3RX9503-0BA00 (selectable)
For special applications
3A 24 V DC 3RX9501-1BA00 1 1 unit 42C
2.6 A/max. 100 W 120/230 V AC (selectable) 3RX9501-2BA00 1 1 unit 42C

* You can order this quantity or a multiple thereof.


2/68 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Power supply units and data decoupling modules
30 V power supply units

■ Overview
The PSN130S 30 V power supply units feed 30 V DC into the
AS-Interface cable and supply the AS-Interface components,
but do not include data decoupling. Data decoupling modules

2
are needed in addition therefore to separate communication
signals and control supply voltage, see page 2/71 or 2/73.
The power supply units are resistant to overload and short
circuits.
Dimensions
The 30 V power supply units have compact dimensions with
widths of 50 and 70 mm. No distances from other devices need
to be observed when mounting the power supply units.
Features
• Primary switched-mode power supplies for connection to
a 1-phase AC system
• Power for currents of 3 A, 4 A and 8 A
• The output voltage is floating, and resistant to short-circuits
PSN130S 30 V power supply units for 3 A, 4 A and 8 A and no-load operation. If there is an overload, the output
voltage is reduced or cut-off. After a short circuit or overload,
More information the devices start up again automatically.
For operating instructions and other technical information, see • In the event of a device fault, the output voltage will be limited
https://support.industry.siemens.com/cs/ww/en/view/64364000 and
https://support.industry.siemens.com/cs/ww/en/view/44030789
to max. 37 V.
• Modular installation devices in degree of protection IP20 and
protection class I
• Diagnostics: With an output voltage > 26.5 V DC, the green
LED (30 V O.K.) is lit and the signaling contact 13-14 is closed.

■ Benefits
• Low-cost alternative solution for supplying AS-Interface • Reliable power supply even for large numbers of AS-Interface
networks while making full use of the maximum possible cable modules with a high power requirement
length per AS-i segment • Can be used world-wide thanks to, for example, UL/CSA
• Cost advantage particularly for multiple networks approval (UL 508)
• Compact, space-saving dimensions

■ Application
Configuration examples of AS-Interface networks with a 30 V power supply unit

PROFINET S7-1200 and


IC01_00221d
CM 1243-2 multiple AS-i master with
DCM 1271 data decoupling module

SIMATIC ET 200SP
IC01_00222a

with 2 x CM AS-i Master ST


and
double data decoupling module

AS-Interface
PSN130S
PSN130S 30 V power supply unit
30 V power
supply unit AS-Interface AS-Interface

AS-Interface AS-Interface

I/O modules I/O modules

Configuration of AS-Interface multiple networks with one PSN130S 30 V power supply unit (examples with schematic representation):
Left: Double network based on the S22.5 double data decoupling module and a SIMATIC ET 200SP with two CM AS-i Master ST modules
Right: Triple network based on the SIMATIC S7-1200 with DCM 1271 data decoupling modules and CM 1243-2 communications processors

Siemens IC 10 · 2023 2/69


© Siemens 2023

Industrial communication
AS-Interface
Power supply units and data decoupling modules
30 V power supply units

■ Technical specifications
PSN130S 30 V DC power supply unit 3A 4A 8A PSN130S 30 V DC power supply unit 3A 4A 8A
Input data Protection and monitoring
2

• Input voltage, rated value Ue V AC 120/230 V, 1-phase, • Output overvoltage protection V < 37
automatic selection • Current limiting, typ. A 4 5.5 11
• Range of input voltage V AC 85 ... 132/174 ... 264 Operating data
• Mains frequency Hz 50/60 Ambient temperature
• Power consumption at full load, typ. W 103 139 270 • Operation °C -20 ... +70
Output data • Transportation/storage °C -40 ... +85
• Output voltage, rated value Ua V DC 30 Pollution degree 2
• Residual ripple mVpp < 150 Humidity class Climate class according
• Output current, rated value A 3 4 8 to DIN 50010, relative air
at -20 ... +60 °C humidity max. 100%,
• Max. output current A 3 3 4 without condensation
at +60 ... +70 °C Dimensions and weight
Degree of efficiency under rated conditions • Width mm 50 50 70
• Degree of efficiency % 87 88 90 • Height x depth mm 125 x 126.5
• Power loss, typ. W 12 17 25 • Weight kg 0.4 0.4 0.7

■ Selection and ordering data


Version Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price
per PU
PSN130S 30 V DC power supply unit
(without AS-i data decoupling)
• Output voltage 30 V DC
• Output voltage ES1 according to IEC 62368-1
• Dimensions:
Width: 50 mm (3 A/4 A); 70 mm (8 A);
Height: 125 mm;
Depth: 126.5 mm

3RX9511-0AA00 Output current Input voltage


3A 120/230 V AC 3RX9511-0AA00 1 1 unit 42C
(automatic selection)
4A 120/230 V AC 3RX9512-0AA00 1 1 unit 42C
(automatic selection)
8A 120/230 V AC 3RX9513-0AA00 1 1 unit 42C
(automatic selection)

3RX9512-0AA00

3RX9513-0AA00

* You can order this quantity or a multiple thereof.


2/70 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Power supply units and data decoupling modules
S22.5 data decoupling modules

■ Overview ■ Benefits
• Compatible expansion of the AS-Interface system
• An existing standard power supply unit with 24 V DC or

2
30 V DC can be used for supplying AS-i networks
• The AS-Interface system can also be used in tightly budgeted
applications because no AS-Interface power supply unit
needs to be purchased
• Applications benefit in addition from the advantages of
a modern bus system:
- High level of standardization
- Additional diagnostics and maintenance information
- Faster commissioning
• Easy and cost-efficient design of single and multiple networks
is possible

■ Application
The AS-Interface data decoupling module is designed for
AS-Interface networks with 30 V or 24 V supply (AS-i Power24V).
AS-Interface S22.5 double data decoupling module: Operation of an AS-i network with the data decoupling module
Screw terminal version (picture on left),
Spring-loaded terminal version (picture on right)
and a 30 V standard power supply unit is technically equivalent
to the use of an AS-Interface power supply unit and offers the
More information service-proven features of AS-Interface for all applications.
Operating Instructions, see AS-Interface Power24V uses a 24 V power supply unit in
https://support.industry.siemens.com/cs/ww/en/view/44030789 conjunction with a data decoupling module and is particularly
More information on AS-i Power24V, see suitable for:
System Manual for AS-Interface,
https://support.industry.siemens.com/cs/ww/en/view/26250840 • Compact machines using AS-Interface input/output modules
• Applications in the control cabinet for AS-Interface integration
With the aid of the S22.5 data decoupling module, the of SIRIUS 3RT2 contactors using 3RA27 function modules
AS-Interface network can also be supplied with 24 V DC or
30 V DC from a standard power supply unit and the transmission When using the double data decoupling module or other
of data and power can be realized along one cable. data decoupling units, several AS-Interface networks can be
operated with a single power supply unit. This results in an
The combination of data decoupling modules and standard additional cost advantage.
power supply units is therefore a cost-efficient alternative to
the service-proven AS-Interface power supply units. Note:
The quality of the data signals and the reliable operation of The power supply units must comply with the ES1 (IEC 62368-1)
the AS-i network are not negatively affected as the result. or PELV (Protective Extra Low Voltage)/SELV (Safety Extra Low
Voltage) standards, have a residual ripple of < 250 mVpp, and
Features of the S22.5 data decoupling module must limit the output voltage to a maximum of 40 V in the event
• Degree of protection IP20 of a fault.
• Narrow design: 22.5 mm wide We recommend
• Version with screw or spring-loaded terminals • SITOP power supplies, see page 15/1 or Catalog KT 10.1,
• Versions for single and double data decoupling https://support.industry.siemens.com/cs/ww/en/view/109745655.
• Supply of several AS-i networks with a single power supply unit • PSN130S 30 V power supply units, see page 2/69
• Operation with 24 V DC or 30 V DC, grounded or non-grounded Note on AS-i Power24V:
• Adjustable current limiting up to 2 x 4 A The length of an AS-i Power24V network is restricted to 50 m in
• Integrated ground-fault detection with fault storage, display order to limit the voltage drop along the cable.
can optionally be switched off AS-i masters, AS-i slaves and the sensors and actuators
• Diagnostics LEDs and signaling contacts supplied through the AS-i cable must be designed for the
• RESET by button or Remote RESET reduced voltage. Sensors and actuators for the standard voltage
range of 10 to 30 V can be supplied with sufficient voltage.
Ground-fault detection
Please also observe the requirements specified in
The integrated ground-fault detection works with a grounded "AS-i Power24V" for the operation of an AS-i Power24V network,
and non-grounded supply: The connection of negative pole and see page 2/23.
ground (upstream from the data decoupling module) customary
with 24 V DC power supplies is permitted. A ground fault to For more information on AS-i Power24V, see System Manual for
the negative or positive pole on the AS-Interface network AS-Interface,
(downstream from the data decoupling module) is detected https://support.industry.siemens.com/cs/ww/en/view/26250840.
and stored as a fault and will be signaled using LEDs and
a relay contact.
Using the ground-fault detection in the AS-i master is
recommended for non-grounded supply. In this case,
the ground-fault indicator can be deactivated in the data
decoupling module to avoid any unwanted LED messages.

Siemens IC 10 · 2023 2/71


© Siemens 2023

Industrial communication
AS-Interface
Power supply units and data decoupling modules
S22.5 data decoupling modules
Configuration of an AS-i Power24V network with AS-Interface S22.5 data decoupling module

PROFINET PROFINET
2

S7-300 with CP 343-2P/CP 343-2 S7-300 with CP 343-2P/CP 343-2


and 24 V standard power supply unit and 24 V standard power supply unit

Single Up to 50 m Double Up to 50 m
data data
decoupling decoupling
module AS-Interface module AS-Interface

NSB0_02191b

I/O modules I/O modules

AS-Interface

NSB0_02192b
I/O modules

Single network Multiple network

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

S22.5 data decoupling modules Screw terminals


With screw terminals, removable terminals,
width 22.5 mm, height 101 mm, depth 115 mm
• Single data decoupling module, 1 x 4 A 3RK1901-1DE12-1AA0 1 1 unit 42C
• Double data decoupling module, 2 x 4 A 3RK1901-1DE22-1AA0 1 1 unit 42C

3RK1901-1DE12-1AA0
S22.5 data decoupling modules Spring-loaded
With spring-loaded terminals, removable terminals, terminals
width 22.5 mm, height 105 mm, depth 115 mm
• Single data decoupling module, 1 x 4 A 3RK1901-1DG12-1AA0 1 1 unit 42C
• Double data decoupling module, 2 x 4 A 3RK1901-1DG22-1AA0 1 1 unit 42C

3RK1901-1DG12-1AA0

* You can order this quantity or a multiple thereof.


2/72 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
Power supply units and data decoupling modules
Data decoupling modules for S7-1200 > DCM 1271 data decoupling module

■ Overview
The DCM 1271 data decoupling module has the same enclosure
design as the S7-1200 module and is therefore ideal for
combining with the CM 1243-2 AS-i master.

2
The DCM 1271 data decoupling module has no connection to
the backplane bus of the SIMATIC S7-1200 and is not counted
as a communications module when calculating the maximum
configuration.
Features of the DCM 1271 data decoupling module
• Design: S7-1200, width 30 mm, degree of protection IP20
• Detachable terminals (included in the scope of supply)
• Single data decoupling
• Supply of several AS-i networks with a single power supply unit
• Operation with 24 V DC or 30 V DC, grounded or non-grounded
• Current limiting at 4 A
• Integrated ground-fault detection
• Diagnostics LEDs for ground faults and overloads
DCM 1271 data decoupling module for SIMATIC S7-1200
• Signaling contacts for ground-fault detection
More information
Ground-fault detection
Manual for AS-i master CM 1234-2 and AS-i DCM 1271 data decoupling
module, see https://support.industry.siemens.com/cs/ww/en/view/57358958 The integrated ground-fault detection works with a grounded
For more information on AS-i Power24V, see and non-grounded supply: The connection of negative pole and
System Manual for AS-Interface, ground (upstream from the data decoupling module) customary
https://support.industry.siemens.com/cs/ww/en/view/26250840 with 24 V DC power supplies is permitted. A ground fault to
the negative or positive pole on the AS-Interface network
With the aid of the DCM 1271 data decoupling module,
(downstream of the data decoupling module) is identified
the AS-Interface network can also be supplied with 24 V DC or
and signaled via LED and a transistor output.
30 V DC from a standard power supply unit and the transmission
of data and power can be realized along one cable.

■ Benefits
• An existing standard power supply unit with 24 V DC or
30 V DC can be used for supplying AS-i networks
• The AS-Interface system can also be used in tightly budgeted
applications because no AS-Interface power supply unit
needs to be purchased
• Applications benefit in addition from the advantages of
a modern bus system:
- High level of standardization
- Additional diagnostics and maintenance information
- Faster commissioning

Siemens IC 10 · 2023 2/73


© Siemens 2023

Industrial communication
AS-Interface
Power supply units and data decoupling modules
Data decoupling modules for S7-1200 > DCM 1271 data decoupling module

■ Application
The AS-Interface data decoupling module is designed for Note on AS-i Power24V:
AS-Interface networks with 30 V or 24 V supply (AS-i Power24V).
The length of an AS-i Power24V network is restricted to 50 m in
2

Operation of an AS-i network with the data decoupling module order to limit the voltage drop along the cable.
and a 30 V standard power supply unit is technically equivalent
to the use of an AS-Interface power supply unit and offers the AS-i masters, AS-i slaves and the sensors and actuators
service-proven features of AS-Interface for all applications. supplied through the AS-i cable must be designed for the
reduced voltage. Sensors and actuators for the standard voltage
AS-i Power24V uses a 24 V power supply unit in conjunction with range of 10 to 30 V can be supplied with sufficient voltage.
a data decoupling module and is particularly suitable for
Please also observe the requirements specified in
• Compact machines using AS-Interface input/output modules "AS-i Power24V" for the operation of an AS-i Power24V network,
• Applications in the control cabinet for AS-Interface integration see page 2/23.
of SIRIUS 3RT2 contactors using 3RA27 function modules For more information on AS-i Power24V, see System Manual for
Note: AS-Interface,
https://support.industry.siemens.com/cs/ww/en/view/26250840.
The power supply units must comply with the ES1 (IEC 62368-1)
or PELV (Protective Extra Low Voltage)/SELV (Safety Extra Low
Voltage) standards, have a residual ripple of < 250 mVpp, and PROFINET
must limit the output voltage to a maximum of 40 V in the event
of a fault. S7-1200 with DCM 1271, CM 1243-2
We recommend and 24 V standard power supply unit

• SITOP power supplies, see page 15/1 or Catalog KT 10.1,


https://support.industry.siemens.com/cs/ww/en/view/109745655.
• PSN130S 30 V power supply units, see page 2/69 Up to 50 m

AS-Interface

NSB0_02245a
I/O modules

Configuration of an AS-i Power24V network with DCM 1271 AS-Interface


data decoupling module

2/74 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
Power supply units and data decoupling modules
Data decoupling modules for S7-1200 > DCM 1271 data decoupling module

■ Selection and ordering data


Version Screw terminals PU PS* PG
(UNIT,

2
SET, M)
Article No. Price
per PU
DCM 1271 data decoupling module 3RK7271-1AA30-0AA0 1 1 unit 42C
• Max. current: 1 x 4 A
• Removable terminals (included in the scope of supply)
• Dimensions W x H x D (mm): 30 x 100 x 75

3RK7271-1AA30-0AA0

■ Accessories
Version Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price
per PU
Screw terminals (spare part)
• 5-pole, 3RK1901-3MA00 1 1 unit 42C
For AS-i master CM 1243-2 and AS-i DCM 1271 data
decoupling module
• 3-pole, 3RK1901-3MB00 1 1 unit 42C
For AS-i DCM 1271 data decoupling module for
connecting the power supply unit
CM 1243-2 communications module 3RK7243-2AA30-0XB0 1 1 unit 42C
• AS-Interface master for SIMATIC S7-1200
• Corresponds to AS-Interface specification V3.0
• Removable terminals (included in the scope of supply)
• Dimensions W x H x D (mm): 30 x 100 x 75
See also from page 2/37 onwards

3RK7243-2AA30-0XB0

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/75
© Siemens 2023

Industrial communication
AS-Interface
Transmission media
AS-Interface shaped cable

■ Overview
To enable use in the most varied ambient conditions (e.g. in an
oily environment), the AS-Interface cable is available in different
materials (rubber, TPE, PUR).
2

For special applications it is also possible to use an unshielded


standard round cable H05VV-F 2 x 1.5 mm² according to
AS-i specification. With AS-Interface, data and energy for the
sensors (e.g. proximity switches) and actuators (e.g. indicator
lights) are transmitted over the yellow AS-Interface cable.
The black AS-Interface cable must be used for actuators with
a 24 V DC supply (e.g. solenoid valves) and a high power
requirement.
Suitable for operation in cable carriers
The use of the AS-Interface shaped cables with TPE and PUR
outer sheath was checked in a cable carrier test with the
following conditions:
Chain length m 6
AS-Interface shaped cable Travel m 10
Bending radius mm 75
The actuator-sensor interface – the networking system used for
the lowest field area – is characterized by very easy mounting Travel speed m/s 4
and installation. A new connection method was developed Acceleration m/s2 4
specially for AS-Interface. Number of cycles 10 million
The stations are connected using the AS-Interface cable. Duration of test approx. 3 years (11 000 cycles per day)
This two-wire AS-Interface shaped cable has a trapezoidal After termination of the 10 million cycles only slight wear was
shape, thus ruling out polarity reversal. visible due to the lugs of the cable carrier. No damage to the
Connection is effected by the insulation piercing method. cores and core insulation could be detected.
In other words, male contacts pierce the AS-Interface shaped Note:
cable and make reliable contact with the two wires. Cutting
to length and stripping are superfluous. Consequently, When using a cable carrier, the cables must be installed in such
AS-Interface stations (e.g. I/O modules, intelligent devices) a way that they are not subject to tensile forces. On no account
can be connected in the shortest possible time and exchanging may the cables be twisted, but they must be routed flat through
devices is quick. the cable carrier.

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

AS-Interface shaped cables


Material Color Quantity
Rubber Yellow (AS-Interface) 100 m roll 3RX9010-0AA00 1 1 unit 42C
Yellow (AS-Interface) 1 km drum 3RX9012-0AA00 1 1 unit 42C
Black (24 V DC) 100 m roll 3RX9020-0AA00 1 1 unit 42C
Black (24 V DC) 1 km drum 3RX9022-0AA00 1 1 unit 42C
TPE Yellow (AS-Interface) 100 m roll 3RX9013-0AA00 1 1 unit 42C
3RX90..-0AA00
Yellow (AS-Interface) 1 km drum 3RX9014-0AA00 1 1 unit 42C
Black (24 V DC) 100 m roll 3RX9023-0AA00 1 1 unit 42C
Black (24 V DC) 1 km drum 3RX9024-0AA00 1 1 unit 42C
TPE special Yellow (AS-Interface) 100 m roll 3RX9017-0AA00 1 1 unit 42C
version according Black (24 V DC) 100 m roll 3RX9027-0AA00 1 1 unit 42C
to UL Class 2
PUR Yellow (AS-Interface) 100 m roll 3RX9015-0AA00 1 1 unit 42C
Yellow (AS-Interface) 1 km drum 3RX9016-0AA00 1 1 unit 42C
Black (24 V DC) 100 m roll 3RX9025-0AA00 1 1 unit 42C
Black (24 V DC) 1 km drum 3RX9026-0AA00 1 1 unit 42C

* You can order this quantity or a multiple thereof.


2/76 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
System components and accessories
Repeaters

■ Overview
• A repeater adds an extra segment to an existing segment.
The extra segment can have a cable length of up to 100 m

2
(without extension plug) or up to 200 m (with an extension
plug in the extra segment)
• Each segment requires a separate AS-i power supply unit
The repeater is automatically supplied with power by the
AS-i power supply units.
• Electrical separation of the two AS-Interface shaped cable
lines, e.g. interfering signals or ground faults are blocked at
the repeater. The wanted signals are prepared by the repeater
and passed on after amplification.
• Slaves can be used on both sides of the repeater because the
repeater has a symmetrical internal structure. The AS-i master
can be positioned before or after the repeater.
AS-Interface repeater • The additional power supply can increase the current infeed for
slaves/sensors and lower the voltage drop on the AS-i cable
The AS-Interface repeater is used to extend the AS-Interface
• Separate display of the correct AS-Interface voltage by means
cable.
of LED for each segment
• In its basic version, an AS-i network comprises one segment
• Installed in K45 module enclosure IP67 with mounting plate
with a maximum cable length of 100 m. An extension plug
(see page 2/79) can be used to increase the cable length for • Easy mounting
a segment to a maximum of 200 m.
• If this is insufficient, however, you can use one or more
repeaters

■ Benefits
• More possibilities of use and greater freedom for plant In safety-related applications the following also applies:
planning through extension of the AS-Interface network • When used without an extension plug, no more than two
• Reduced downtime and servicing times in the event of a fault repeaters are permitted between evaluation unit (e.g.
thanks to separate display of the correct AS-Interface voltage F-CM AS-i Safety ST for ET 200SP) and ASIsafe input slave
for each side or safe output module.
• Increased operational reliability in extensive networks due to • When used with an extension plug, no more than
conditioning and amplification of the wanted signals. one repeater is permitted between the evaluation unit
(e.g. F-CM AS-i Safety ST for ET 200SP) and ASIsafe input
Design of an AS-Interface network with repeaters slave or safe output module.
• Parallel connection of several repeaters possible
(star configuration) Note:
• Combination of series and parallel connection possible The open end of an AS-i bus cable must not be in the
AS-Interface repeater. The AS-Interface shaped cable can
The following conditions apply to enable the signal propagation be terminated by means of a cable end terminator to provide
times to be maintained: degree of protection IP67 where required, see "Miscellaneous
• When used without an extension plug no more than two accessories" on page 2/86.
repeaters are permitted between AS-i master and slave The AS-Interface repeater is not suitable for AS-i Power24V
(repeaters connected in series) networks. It is recommended for use in AS-Interface networks
• When used with an extension plug no more than one repeater with AS-Interface power supply units (e.g. 3RX9501-0BA00).
is permitted between AS-i master and slave

ET 200SP with
CM AS-i Master ST
and optional
F-CM AS-i Safety ST

AS-Interface AS-Interface AS-Interface


power supply AS-Interface power supply AS-Interface power supply
power supply power supply

I/O modules Repeater I/O modules Repeater Repeater I/O modules


I/O modules I/O modules
IC01_00789
Repeater
AS-Interface
100 m 100 m 100 m 100 m 100 m
500 m network extension

Design of an example AS-Interface network with repeaters (without extension plug)

Siemens IC 10 · 2023 2/77


© Siemens 2023

Industrial communication
AS-Interface
System components and accessories
Repeaters

■ Application
The repeater is used to extend the AS-Interface network. In this In an example configuration with two repeaters and three
case there are AS-Interface slaves and one AS-Interface power extension plugs, the maximum possible size of the AS-Interface
supply unit on each side of the repeater. network is 600 m, see example configuration with extension plug
2

on page 2/79.
As with all AS-Interface networks, any network structure (line,
tree, star) is possible.

■ Selection and ordering data


.

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Repeaters for AS-Interface 6GK1210-0SA01 1 1 unit 42C


• Cable extension due to expansion of an existing cable
segment by an additional segment
• Doubling of the total cable length to 200 m when a repeater
is used
• Amplification of the wanted signals
• Delivery includes mounting plate
6GK1210-0SA01 (for wall and DIN-rail mounting)
• Direct connection to AS-Interface shaped cable using the
insulation displacement method
• Repeater does not require an AS-i address

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Cable end terminator 3RK1901-1MN00 1 10 units 42C


For sealing open cable ends
(AS-Interface shaped cable) with IP67

3RK1901-1MN00

* You can order this quantity or a multiple thereof.


2/78 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
System components and accessories
Extension plugs

■ Overview
Design of an AS-Interface segment with an extension plug
To construct an AS-Interface segment with a cable length of more

2
than 100 m and up to a maximum of 200 m, the extension plug is
installed in a radius of around 10 m at the point of the network
that is furthest from the AS-i power supply unit (tolerance up to
10 m from the end point). The extension plug is not allowed to be
used in AS-Interface networks smaller than 100 m. Generally,
any network structure (line, tree, star) is possible when using the
extension plug. Only one extension plug is required per 200 m
segment even with a tree or star structure.
The extension plug can be combined with the AS-Interface
AS-Interface Extension Plug Compact repeater, see page 2/78.
With the Extension Plug Compact, it is possible to double the cable Note:
length possible in an AS-Interface segment from 100 to 200 m. The open end of an AS-i bus cable must not be in the extension
Only one AS-i power supply unit is needed to supply power to plug. The AS-Interface shaped cable can be terminated by
the slaves on the up to 200 m long segment. means of a cable end terminator to provide degree of protection
IP67 where required, see "Miscellaneous accessories" on
The extension plug suppresses interfering signals that can arise page 2/86.
due to reflection at the end of a long cable. The extension plug
contains no amplification of the wanted signals. The AS-Interface extension plug is not suitable for
AS-i Power24V networks. It is recommended for use in
The extension plug is mounted directly on the AS-Interface AS-Interface networks with AS-Interface power supply units
shaped cable by means of the insulation displacement method (e.g. 3RX9501-0BA00).
and does not require its own power supply.

ET 200SP with
CM AS-i Master ST
and optional
F-CM AS-i Safety ST

AS-Interface AS-Interface AS-Interface


power supply power supply power supply

Extension
Extension Repeater I/O modules plug Repeater Extension
plug I/O modules I/O modules plug

AS-Interface

200 m 200 m 200 m


600 m
IC01_00788

Example configuration AS-Interface network with repeater and extension plug

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

AS-Interface Extension Plug Compact 3RK1901-1MX02 1 1 unit 42C


• Doubling of the cable length to 200 m per AS-Interface
segment
• Direct connection to AS-Interface shaped cable using the
insulation displacement method
• Extension Plug Compact does not require an AS-i address
3RK1901-1MX02

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Cable end terminator 3RK1901-1MN00 1 10 units 42C


For sealing open cable ends
(AS-Interface shaped cable) with IP67

3RK1901-1MN00
* You can order this quantity or a multiple thereof.
Illustrations are approximate Siemens IC 10 · 2023 2/79
© Siemens 2023

Industrial communication
AS-Interface
System components and accessories
Addressing units

■ Overview Note:
For operation of the addressing unit on an AS-Interface cable
with connected power supply unit, the following applies:
The AS-Interface addressing unit is suitable for standard
2

AS-i networks and AS-i Power24V networks (min. operational


voltage on the AS-Interface cable 19 V).

■ Benefits
• Increased power supply to the slaves to 150 mA
• Better utilization of the battery capacity thanks to improved
circuitry
• Support for the current AS-i specification V3.0
• Expanded display for simultaneously displaying input and
output states
• Clearly recognizable display of status of digital inputs/outputs
in binary format (0/1), optionally also available as hexadecimal
values
• Intuitive display of analog data either as decimal, hexadecimal
or as a percentage (e.g. 100% corresponds to input/output
The innovated addressing unit for AS-Interface of the AS-i specification value 20 mA)
V3.0
• I/O data of complex slaves (CTT2 profile) can be displayed
The addressing unit is used to assign an address during
commissioning to each AS-Interface slave. The device detects • Decoded display of the input data of safe input slaves,
a connected slave module or a complete AS-i network and including code table
displays the found module in the LCD display. Each address can • Simplification of the operating steps when setting the slave
be individually set using the Up/Down keys. By turning the rotary address with automatic read back of the set address
switch, further commissioning functions are selected intuitively. • Addressing cable, ready for operation even without screwing
The innovative device has been adapted to the current in tight into the M12 socket, thus faster availability of the
AS-i specification V3.0 and can now also handle the I/O data addressing unit
of the latest slaves.
• Proven compact housing with smooth keys and rotary switch
Functionality • Connection of standard AS-i networks possible with 30 V as
• Reading out and adjusting the slave address 0 to 31 or 1A to well as Power24V networks
31A, 1B to 31B, with automatic addressing aid and prevention • Complex slaves with high operating currents can be
of double addresses addressed without external supply
• Reading out the slave profile (IO, ID, ID2) • Longer operating time by automatic shutdown after approx.
• Reading out and adjusting the ID1 code 5 minutes (or approx. 1 minute when data exchange is active)
• Input/output test when commissioning the slaves: Read input after last operation
signals and write outputs with all digital and analog slaves • Can be used with all types of digital and analog slaves
according to AS-Interface specification V3.0, including safe • Comprehensive and fast input/output test of plants, even for
input slaves and complex CTT2 slaves A/B slaves with 4 DI/4 DQ and current analog modules with an
• Measuring the voltage on the AS-Interface cable (measuring A/B address
range from 2 to 35 V) • Faster and more reliable commissioning of the AS-Interface
• Display of the operational current in case of direct connection modules
of an AS-i slave (measuring range from 0 to 150 mA) • One-hand operation possible, with unique selection of
• Storage of complete network configurations (profiles of all the functions
slaves) to simplify the addressing • Connection via M12 socket (pin 1: ASI+; pin 3: ASI-;
• Adjusting the slave parameters for commissioning pins 2, 4, 5: not used)
• Reading out the identification and diagnostics of CTT2 slaves • Universal applicability for all AS-i networks
• Reading out the code table of safe input slaves (ASIsafe)

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

AS-Interface addressing unit V3.0 3RK1904-2AB02 1 1 unit 42C


• For AS-Interface modules and sensors and actuators with
integrated AS-Interface according to AS-i specification V3.0
• For setting the AS-i address of slaves with standard addresses,
and slaves with extended addressing mode (A/B slaves)
• With input/output test function and many other commissioning
functions
• Battery operation with four type AA batteries (IEC LR6, NEDA 15)
• Degree of protection IP40
• Dimensions W x H x D (mm): 84 x 195 x 35
• Scope of supply:
3RK1904-2AB02 - Addressing unit with four batteries
- Addressing cable, with M12 plug to addressing plug
(hollow plug), length 1.5 m

* You can order this quantity or a multiple thereof.


2/80 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
System components and accessories
Addressing units

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

2
Addressing cable, with M12 plug to M12 socket1) 3RK1902-4PB15-3AA0 1 1 unit 42D
• For addressing slaves with M12 connection,
e.g. K20 or K60R modules or light curtains
• Length 1.5 m, 3-pole, 3 x 0.34 mm2
3RK1902-4PB15-3AA0
AS-Interface M12 3RX feeder 3RX9801-0AA00 1 1 unit 42C
• Transition of AS-Interface cable to a standard round cable
• Insulation piercing method for connection of AS-Interface
cable
3RX9801-0AA00 • M12 socket for connection of standard round cable
• Current-carrying capacity up to 2 A
AS-Interface M12 3RK feeder 3RK1901-2NR10 1 1 unit 42C
• AS-Interface cable transition without Uaux,
with M12 socket
• Insulation piercing method for connection of AS-Interface
cable
3RK1901-2NR10 • M12 socket for connection of standard round cable
M12 cable plug2) 3RK1902-4HB50-5AA0 1 1 unit 42D
• Extruded M12 plug (angled cable outlet 90°),
other cable end open
• Length: 5 m, 5-pole, color: Black
3RK1902-4HB50-5AA0
M12 plug, straight2) 3RK1902-4BA00-5AA0 1 1 unit 42D
• For screw fixing, 5-pole screw terminal, max. 0.75 mm2
• A-coded, max. 4 A

3RK1902-4BA00-5AA0
Addressing cable, with M12 plug to addressing plug Z236A
(hollow plug)3)
• Included in the scope of supply of the addressing unit
• Length 1.5 m
1)
Not included in scope of supply of the 3RK1904-2AB02 addressing unit.
2) For connecting the addressing unit to an AS-i network via AS-Interface
M12 feeder it is necessary to establish a connection by means of
a connecting cable (M12 plug to M12 connector) which must be wired
as follows:
- M12 cable plug: pin 1/core brown M12 plug: pin 1
- M12 cable plug: pin 3/core blue M12 plug: pin 3
- Pin 2, 4, 5 not connected.
3)
Addressing cable available from:
GMC-I Messtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/81
© Siemens 2023

Industrial communication
AS-Interface
System components and accessories
Analyzer

■ Overview
Connection
2

ET 200SP with
CM AS-i Master ST and
optionally
F-CM AS-i Safety ST

M12 feeder
AS-Interface

Slave Slave Slave Slave

NSA0_00359d
AS-Interface analyzer
AS-Interface analyzer PC
The AS-Interface analyzer is used to test AS-Interface networks.
Installation errors, e.g. loose contacts or EMC interference under Connection of AS-Interface analyzer to PC and AS-Interface network
extreme loads, can be revealed by this device. The AS-Interface analyzer follows the communication on the
Thanks to the easy-to-use software the user can assess the AS-Interface network as a passive station. The unit is supplied
quality of complete networks even if he lacks detailed specialist simultaneously from the AS-Interface cable.
knowledge of AS-Interface. In addition it is an easy matter with This analyzer interprets the physical signals on the AS-Interface
the AS-Interface analyzer to create test logs from the records network and records the communication.
produced, thus providing documentation for startups and
service assignments. The data thus obtained are transferred through an RS 232
interface to a PC such as a notebook, for evaluation with the
For advanced AS-Interface users there are trigger functions for supplied diagnostics software.
detailed diagnostics.

■ Benefits
• Simple and user-friendly operation enables diagnostics of
AS-Interface networks without help from specialists
• Speedy troubleshooting thanks to intuitive display in statistics
mode
• Test logs provide verification of the state and quality of the
installation for service and approval
• Recorded logs facilitate remote diagnostics by
Technical Support
• Comprehensive trigger functions enable exact analysis
• Process data can be monitored online

2/82 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
AS-Interface
System components and accessories
Analyzer

■ Application
Online statistics Data mode

2
Online statistics, overview Presentation of the I/O data: Safety data

Online statistics, details, e.g. here a fault on slave 5 Presentation of the I/O data: Analog values
This mode provides a quick overview of the existing AS-Interface In this mode, the analyzer shows not only the digital input/output
system. The error rates are displayed per slave in a traffic-light values but also the current analog values and the input status of
function (green, yellow, red). the safety slaves.
The bus configuration and the currently transmitted data of
the slaves are shown in a well arranged presentation.
With the expanded statistics function, it is possible to determine
the error rates as the number of transmitted or faulty bus
message frames.
The bundle error overview shows in steps how many multiple
repetitions of message frames occurred in order to enable
a selective and look-ahead assessment of the transmission
quality.

Siemens IC 10 · 2023 2/83


© Siemens 2023

Industrial communication
AS-Interface
System components and accessories
Analyzer
Trace mode Test log
2

Example of a test log

Presentation of message frames in trace mode The recorded data of the online statistics are easy to output and
document using a test log. Verification of the state of the plant
The presentation of message frames in the style of a classic can thus be provided for approvals or service assignments.
fieldbus analyzer is indispensable for complex troubleshooting.
Extensive trigger functions and recording and viewing filters are The integrated measurement assistant records the bus signals
available for this purpose. An external trigger input and trigger for a variable duration, thereby triggering creation of an
output round off the scope of functions in order to find even the automatic test log. A standardized quality test of AS-i plants
most difficult errors. is thus possible.
For troubleshooting in connection with ASIsafe applications, Note:
changes of status in the code tables of safety slaves are The AS-Interface analyzer is suitable for standard AS-i networks
identified and assessed. and AS-i Power24V networks (min. operational voltage 20 V).
The AS-i analyzer can be used with an AS-i master in
accordance with AS-Interface specification V3.0 or
a predecessor version.
The analyzer does not automatically decode the process values
for type CTT2 - CTT5 AS-i slaves. As for other slave types, the
message frames are recorded and evaluated in the statistics.
If required, decoding can also be performed by the user manually.
For more information, see
https://support.industry.siemens.com/cs/ww/en/view/109746763.

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

AS-Interface analyzer 3RK1904-3AB01 1 1 unit 42C


• For testing AS-Interface systems
• For troubleshooting and service assignments in
installations and networks with AS-Interface systems
• Dimensions W x H x D (mm): 145 x 30 x 92
3RK1904-3AB01 • Scope of supply:
- AS-Interface analyzer
- RS 232 cable for connecting to a PC
- USB-to-serial/RS 232 adapter
- Screwdriver
- Magnetic adhesive tape for fastening the analyzer to
metal surfaces
- Service case with foam insert,
dimensions W x H x D (mm): approx. 260 x 70 x 200
- Diagnostics software (CD-ROM) for PC with Windows
operating system

Note:
Download the current version of the diagnostics software for PC
with Windows operating system, see
https://support.industry.siemens.com/cs/ww/en/view/109750259.

* You can order this quantity or a multiple thereof.


2/84 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
System components and accessories
Analyzer

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

2
AS-Interface M12 3RX feeder 3RX9801-0AA00 1 1 unit 42C
• Transition of AS-Interface shaped cable to a standard
round cable
• Insulation piercing method for connection of AS-Interface
3RX9801-0AA00 cable
• M12 socket for connection of standard round cable
• Current-carrying capacity up to 2 A
• Degree of protection IP67
AS-Interface M12 3RK feeder 3RK1901-2NR10 1 1 unit 42C
• AS-Interface cable transition without Uaux,
with M12 socket
• Insulation piercing method for connection of AS-Interface
cable
3RK1901-2NR10
• M12 socket for connection of standard round cable
• Max. 4 A
• Degree of protection IP67/IP68/IP69 (IP69K)
M12 cable plugs 3RK1902-4HB50-5AA0 1 1 unit 42D
• PUR cable, 5-pole
• Length 5 m
3RK1902-4HB50-5AA0 • Color black
• Extruded M12 plug (angled cable outlet 90°), other cable
end open

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/85
© Siemens 2023

Industrial communication
AS-Interface
System components and accessories
Miscellaneous accessories

■ Selection and ordering data


More information
System Manual for AS-Interface, see
2

https://support.industry.siemens.com/cs/ww/en/view/26250840

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

AS-Interface compact distributors, for AS-Interface 1 1 unit 42C


flat cable
• Current-carrying capacity up to 8 A
3RK1901-2NN10 • Degree of protection IP67/IP68/IP69 (IP69K)
For flat For Cable Cable end in
cable length feeder
AS-i or Flat ribbon cable -- Not available 3RK1901-2NN10 1 1 unit 42C
Uaux AS-i or Uaux

AS-Interface M12 3RX feeder


• Current-carrying capacity up to 2 A
• Degree of protection IP67
3RX9801-0AA00 For flat For Cable Cable end in
cable length feeder
AS-i M12 socket -- Available 3RX9801-0AA00 1 1 unit 42C
AS-Interface M12 3RK feeder
• Current-carrying capacity up to 4 A
• Degree of protection IP67/IP68/IP69 (IP69K)
For flat For Cable Cable end in
3RK1901-2NR10 cable length feeder
AS-i M12 socket -- Not available 3RK1901-2NR10 1 1 unit 42C
AS-i M12 cable box 1m Not available 3RK1901-2NR11 1 1 unit 42C
AS-i M12 cable box 2m Not available 3RK1901-2NR12 1 1 unit 42C
AS-i/Uaux M12 socket -- Not available 3RK1901-2NR20 1 1 unit 42C
AS-i/Uaux M12 cable box 1m Not available 3RK1901-2NR21 1 1 unit 42C
AS-i/Uaux M12 cable box 2m Not available 3RK1901-2NR22 1 1 unit 42C
3RK1901-2NR21
AS-Interface M12 feeders, 4-fold
• Current-carrying capacity up to 4 A
• Degree of protection IP67
For flat For Cable Cable end in
cable length feeder
AS-i/Uaux 4-fold M12 socket, -- Not available 3RK1901-1NR04 1 1 unit 42C
delivery includes
3RK1901-1NR04 mounting plate
(for wall and DIN-rail
mounting)
M12 Y-shaped coupler plugs 6ES7194-1KA01-0XA0 1 1 unit 250
For connection of two sensors to one M12 socket with
Y-assignment

6ES7194-1KA01-0XA0
AS-Interface sealing caps
For free M12 sockets
• M12
3RK1901- 3RK1901- - Standard version 3RK1901-1KA00 100 10 units 42C
1KA00 1KA01
- Tamper proof 3RK1901-1KA01 100 10 units 42C
• M8 standard version 3RK1901-1PN00 100 10 units 42C

3RK1901-1PN00
AS-Interface M20 seals 3RK1901-1MD00 100 10 units 42C
• For AS-Interface shaped cable
• For insertion in M20 glands
3RK1901-1MD00

* You can order this quantity or a multiple thereof.


2/86 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
AS-Interface
System components and accessories
Miscellaneous accessories

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

2
Cable adapters for flat cables
Connection of AS-Interface cable to metric gland with
insulation piercing method
• Continuation using standard cable
- For M16 gland 3RK1901-3QM00 1 1 unit 42C
- For M20 gland 3RK1901-3QM10 1 1 unit 42C
• Continuation using pins
3RK1901-3QM00 - For M16 gland 3RK1901-3QM01 1 1 unit 42C
- For M20 gland 3RK1901-3QM11 1 1 unit 42C
Cable clip for cable adapters 3RK1901-3QA00 100 10 units 42C

3RK1901-3QA00
Cable end terminator 3RK1901-1MN00 1 10 units 42C
For sealing open cable ends of the AS-Interface shaped
cable with IP67

3RK1901-1MN00
Mounting plates
• K45
- For wall mounting 3RK1901-2EA00 1 1 unit 42C
- For DIN-rail mounting 3RK1901-2DA00 1 1 unit 42C
• K60, suitable for all K60 compact modules
- For wall mounting 3RK1901-0CA00 1 1 unit 42C
- For DIN-rail mounting 3RK1901-0CB01 1 1 unit 42C
3RK1901- 3RK1901-
2EA00 0CA00
Sealing set 3RK1902-0AR00 100 5 units 42D
• For K60 mounting plate
• Cannot be used for K45 mounting plate
3RK1902-0AR00 • One set contains one straight and one shaped seal
Control cable, assembled at one end
Angled M12 socket for screw fixing, 4-pole, 4 x 0.34 mm2,
A-coded, black PUR sheath, max. 4 A
3RK1902-4GB50-4AA0
• Cable length 5 m 3RK1902-4GB50-4AA0 1 1 unit 42D
M12 socket, angled 3RK1902-4CA00-4AA0 1 1 unit 42D
For screw fixing, 4-pole screw terminals, max. 0.75 mm2,
A-coded, max. 4 A

3RK1902-4CA00-4AA0
M12 plugs
For screw fixing, 5-pole screw terminals, max. 0.75 mm2,
A-coded, max. 4 A
3RK1902-4BA00-5AA0 • Straight 3RK1902-4BA00-5AA0 1 1 unit 42D
• Angled 3RK1902-4DA00-5AA0 1 1 unit 42D

3RK1902-4DA00-5AA0
Control cable, assembled at one end
Angled M12 plug for screw fixing, 5-pole, 5 x 0.34 mm2,
A-coded, black PUR sheath, max. 4 A
3RK1902-4H...-5AA0 • Cable length 1.5 m 3RK1902-4HB15-5AA0 1 1 unit 42D
• Cable length 5 m 3RK1902-4HB50-5AA0 1 1 unit 42D
• Cable length 10 m 3RK1902-4HC01-5AA0 1 1 unit 42D
Control cable, assembled at both ends 3RK1902-4PB15-3AA0 1 1 unit 42D

3RK1902-4PB15-3AA0 Straight M12 plug, straight M12 socket, for screw fixing,
3-pole, 3 x 0.34 mm2,
A-coded, black PUR sheath, max. 4 A
• Cable length 1.5 m
• Also for addressing AS-i slaves with
M12 bus connection (e.g. K20, K60R compact modules,
M200D motor starters)

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/87
© Siemens 2023

Industrial communication
IO-Link
Introduction
Communications overview

■ Overview
More information
Homepage, see www.siemens.com/io-link For brochure, see
2

TIA Selection Tool Cloud (TST Cloud), see https://assets.new.siemens.com/siemens/assets/api/uuid:7460eb69-efa0-


www.siemens.com/tstcloud/?node=IoLink 4426-9213-af4d3619b567/dffa-b10447-01broschuereiolinkdeengb-144.pdf
For important topics at a glance, see
https://support.industry.siemens.com/cs/ww/en/view/109737170

IO-Link is an open communication standard for sensors and


actuators – defined by the PROFIBUS User Organization (PNO).
IO-Link technology is based on the point-to-point connection of
sensors and actuators to the control system.
Parameter and diagnostics data are transmitted in addition to
Video: The open communication standard IO-Link the cyclic operating data for the connected sensors/actuators.
The simple, unshielded three-wire cable customary for standard
sensors is used for this purpose.

Remote access, Telecontrol stations (RTUs)


Laptop e.g. via teleservice
ET 200SP
S7-1500 RTU RTU S7-1200
RTU
PC

OpenVPN
RTU3030C

Controller Numeric control


Control and SINEMA Motion control
monitoring system Telecontrol Remote SINEMA PC/PG/IPC Controller
and systems Database Remote
Connect server Connect
substation
control server

Firewall

PROFINET
Industrial Ethernet

Access Access
Controller point point
Controller PC/PG IWLAN
Notebook RCoax cable Industrial Ethernet
switches

Controller
Control and PC/PG/IPC
Field device for monitoring system Wireless
intrinsically safe area Remote devices
maintenance
access SCALANCE
Numeric SC646-2C
Coupler control
Link

PROFIBUS PA PROFIBUS
ASM456 Field devices

Mobile Optical
Field devices reading
Mobile HMI
SIMOCODE RF185C systems
HMI
pro IO-Link RFID system Access
RFID Optical master
reading IO-Link point
system DP slave Motion control
IO-Link systems systems
IO-Link
AS-i master I/O module AS-i master
IO-Link DP/AS-i Link 20E in ET 200SP in ET 200SP
I/O module AS-Interface
power supply Protection and
Slave monitoring Client
devices module
SINAMICS
drives RFID Compact
Compact Signaling column Protection and RFID system feeder
feeder monitoring system
G_IK10_XX_30049e
devices
AS-Interface
Compact
feeder Field device

Slave Slave
Slave Slave
AS-Interface
Compact Signaling column power supply
feeder

IO-Link in the SIMATIC NET communications landscape

2/88 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
IO-Link
Introduction
Communications overview

■ Benefits
Engineering Installation and commissioning
• Standardized, open system for greater flexibility • Faster assembly with minimized error rate as a result of

2
(non-Siemens IO-Link devices can be integrated in reduced control current wiring
engineering) • Less space required in the control cabinet
• Uniform, transparent configuring and programming through • Low-cost circuitry where there are several feeders by making
integrated engineering (SIMATIC STEP 7) full use of existing components
• Unassigned SIMATIC function blocks for easy parameter-
ization, diagnostics and read-out of measured values Operation and maintenance
• Efficient engineering thanks to pre-integration into • High transparency in the system right down to field level and
SIMATIC HMI integration into power management systems
• Low error rate in CAD circuit diagram design as a result of • Reduction in downtimes and maintenance times thanks to
reduced control current wiring system-wide diagnostics and faster fault correction
• Support of predictive maintenance
• Shorter changeover times, even for field devices, by means of
parameter and recipe management

■ Application
IO-Link can be used in the following main applications: Integration in STEP 7
• Easy connection of complex IO-Link sensors/actuators with Integration of the device configuration in the STEP 7
a large number of parameters and diagnostics data to the environment guarantees:
control system
• Quick and easy engineering
• Replacement of sensor boxes for connecting binary sensors
with the IO-Link input modules optimized in terms of cabling • Consistent data storage
• Optimized cable connection of switching devices to the • Quick localization and rectification of faults
control system
• Simple transmission of energy values from the device to the
control system for integration into a user program or power
management
In these cases, all the diagnostics data are transmitted to the
higher-level control system through IO-Link. The parameter
settings can be changed during operation.

Siemens IC 10 · 2023 2/89


© Siemens 2023

Industrial communication
IO-Link
Introduction
System components

■ Overview
2

IO-Link master

IC01_00787
IO-Link devices

IO-Link product family


To implement communication, a system installation has the • An IO-Link master
following main components: • One or more IO-Link devices, such as sensors
(e.g. RFID systems), actuators or combinations thereof
• A standard three-wire sensor/actuator cable

Engineering and visualization

IO-Link
engineering: Visualization:
SIMATIC SIMATIC HMI
S7-PCT WinCC

Switching cabinet installation Field installation

S7-300/ S7-1200/
S7-400 S7-1500
controller controller

PROFINET

ET 200SP SIMATIC
with IO-Link master ET 200eco PN
IO-Link
with IO-Link
master

SIRIUS SIRIUS IO-Link


3RB24 3RS28 I/O module
SIRIUS overload relay
3RA2 load feeders relay
SIRIUS with 3RA27 SIRIUS
3UG48 function modules 3RT2 contactor
relay with SIRIUS
3RR24 relay

3SU1 ID key-
operated switch
IK10_30141h

RF200 RF200 Standard


8WD44/8WD46 RFID system RFID system sensors
signaling column Actuators

Example of a configuration with the system components

2/90 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
IO-Link
Introduction
System components
IO-Link compatibility Overload relays
IO-Link ensures compatibility between IO-Link-capable A starter combination, for example, consists of one or more
modules and standard modules as follows: SIRIUS 3RT contactors and one 3RB24 electronic overload relay
• IO-Link sensors can generally be operated both on for IO-Link plus its 3RB29 current measuring module.

2
IO-Link modules (masters) and standard input modules. 3RB24 overload relays with IO-Link are basically designed
• IO-Link sensors/actuators as well as today's standard to provide current-dependent protection for loads against
sensors/actuators can be used on IO-Link masters. inadmissibly high temperature rises due to overload, phase
• If conventional components are used in the IO-Link system, asymmetry or phase failure.
then of course only the standard functions are available at Direct-on-line starters can, therefore, as shown in the image,
this point. be connected to the control system via IO-Link without much
wiring. Remote control of connected contactors, current value
Analog signals transmission and immediate remote fault diagnosis are just
Another advantage of IO-Link technology is that analog signals some examples of the large number of functions that can be
are already digitized in the IO-Link sensor itself and are digitally implemented with this device.
transmitted via IO-Link communication. As the result, faults are It is also possible to directly address a drive on-site via IO-Link
prevented and there is no extra cost for cable shielding. using the optional handheld device.
Enhancement with IO-Link input modules
IO-Link compatibility also permits connection of standard Programmable logic
sensors/actuators, i.e. conventional sensors/actuators can also controller (PLC)
CPU S7-1200 SM 1278 4 x IO-Link master
be connected to IO-Link. This is particularly cost-effective with
the IO-Link input modules, which allow several sensors to be Feeder
connected at one time via a cable to the controller.

3RV motor starter


protector
IO-Link and 3RT contactor

3RB29
current
SIRIUS 3RB24 measuring
electronic overload relay module
and 3RA69 handheld device

IC01_00295
Motor

Connection of an IO-Link-capable overload relay to a SIMATIC S7-1200


controller
Load feeders and motor starters
Through IO-Link it is possible to control not only sensors but also
actuators in the form of load feeders and motor starters.

ET 200SP ET 200SP with


with IO-Link master digital I/O modules

Point-to-point Classic
connection wiring
through IO-Link
IO-Link

IO-Link Sensor
I/O module box
NSA0_00489f

Sensors Actuators Actuators Sensors

Possibilities of connecting load feeders and motor starters to IO-Link or


in the conventional way

Siemens IC 10 · 2023 2/91


© Siemens 2023

Industrial communication
IO-Link
Introduction
System components
Monitoring relays
By using monitoring relays with IO-Link it is now possible to
send data that has already been recorded and evaluated in
the devices directly to the controller. This avoids the use of
2

duplicated sensors.

3 1
3UG46
monitoring 3UG48
relay monitoring
Feeder relay Feeder

ET 200SP
with IO-Link
master ET 200SP
with IO-Link master

1 Analog 2 IO-Link
signal 3UG46 3UG46
converter monitoring monitoring
relay relay 1 2
3UG48 3UG48
monitoring monitoring
relay relay

Current
trans-
former

IC01_00003a IC01_00004a

Motor Motor

1 Signaling of limit value violation plus measurement data 1 Signaling of limit value violation plus measurement data
transmission to PLC transmission to PLC
2 Autonomous operation without PLC 2 Autonomous operation without PLC
3 Signaling of limit value violation to PLC

Possibilities for interfacing conventional 3UG46 monitoring relays Possibilities of interfacing 3UG48 monitoring relays for IO-Link
(in comparison with 3UG48)

2/92 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
IO-Link
Introduction
System components
Wireless communication
Using an upstream IWLAN client module, such as The individual diagnostics options offered by the various IO-Link
SCALANCE W722-1 RJ45, allows IO-Link to be integrated into devices provide greater transparency for the production
the PROFINET world via a distributed I/O. Possible uses include process. Just like the parameter data for a device, these

2
acting as an alternative to fault-prone cable carrier or collector diagnostics data can be evaluated remotely using the
wire technology. possibilities offered by SIMATIC. This supports remote
maintenance down to the lowest level in the field.

Pump station Maintenance station

SCALANCE
W722-1 RJ45
ET 200SP
with IO-Link master

Industrial Ethernet
SIRIUS
3RA2 load feeders
with 3RA27 Control room
function modules

SIMATIC HMI
KTP 1500 Basic
SIMATIC
S7-300
IO-Link

Industrial Ethernet

SCALANCE

IC01_00198c
W786-1 RJ45
access point

Wireless communication between Industrial Ethernet and IO-Link components

Siemens IC 10 · 2023 2/93


© Siemens 2023

Industrial communication
IO-Link
Introduction
System components
IO-Link components
IO-Link masters IO-Link devices (continued)
Masters Monitoring with IO-Link
IO-Link master module for S7-1500 SIRIUS 3RR24 monitoring relays for mounting on
2

• CM 8xIO-Link, see page 2/97 3RT2 contactors for IO-Link


IO-Link master module for S7-1200 • Monitoring of current, phase failure, open circuit and
phase sequence
• SM 1278 4xIO-Link, see page 2/98 • Designed for mounting on 3RT2 contactors
IO-Link master module for ET 200SP • Terminal supports for stand-alone installation for
SIRIUS 3RR24 separate mounting
• CM 4xIO-Link V1.1 Standard, see page 2/99
CM 8xIO-Link monitoring relay See page 10/55 onwards
IO-Link master module for ET 200pro
for S7-1500 SIRIUS 3UG48 monitoring relays for stand-alone
• 4 IO-Link HF, see page 2/100 installation for IO-Link
IO-Link master module for ET 200eco PN • Monitoring the supply system, voltage, current,
• IO-Link master 4 IO-L + 8 DI + 4 DO 24 V DC/1.3 A power factor and active current, residual current or
• IO-Link master 4 IO-L speed depending on device design
• IO-Link master 8 IO-L + 4 DI 24 V DC • On/tripping delay time can be adjusted
See page 2/101 SIRIUS 3UG48 See page 10/96 onwards
IO-Link master module for ET 200AL monitoring relay
• CM IO-Link, see page 2/102 SIRIUS 3RS28 temperature monitoring relay for
IO-Link
For full product range, see Catalog ST 70.
• Digital device for temperature monitoring with
IO-Link devices connected sensors
Detection and output with IO-Link • Two limit values, can be adjusted separately
See page 10/119 onwards
IO-Link digital modules
SIRIUS 3RS28
IO-Link I/O modules temperature
• IO-Link, digital input modules monitoring relay
- DI 8 x 24 V DC, 8 x M8 Actuating and indicating with IO-Link
- DI 16 x 24 V DC, 8 x M12
SIRIUS ACT 3SU1 ID key-operated switches for
• IO-Link, digital output modules IO-Link
- DQ 8 x 24 V DC/2 A, 8 x M12
IO-Link I/O • Access system and selection system for four
modules • IO-Link, digital input/output modules authorization levels
- DIQ 4+DQ 4 x 24 V DC/0.5 A, 8 x M8 • Authentication of groups and persons
- DIQ 16 x 24 V DC/0.5 A, 8 x M12 SIRIUS ACT • Five ID keys with different coding
See page 2/103 3SU1 ID key- • Option for individual coding via IO-Link
operated switch • For installation in enclosures or fastening on front plate
Switching with IO-Link
• Solid-state module for ID key-operated switches must
Contactors and contactor assemblies be ordered separately.
SIRIUS 3RT contactors, 3-pole up to 250 kW, See page 13/12
see page 3/18 onwards SIRIUS ACT 3SU1 solid-state modules for IO-Link
SIRIUS 3RA23 reversing contactor assemblies, • Eight digital inputs and outputs possible
up to 55 kW, see page 3/142 onwards • DI and DQ freely selectable (programmable)
SIRIUS 3RA2711 SIRIUS 3RA24 contactor assemblies for star-delta • Input and output functions parameterizable
function module (wye-delta) starting, up to 90 kW, see page 3/158 • Connection method (push-in)
for IO-Link onwards SIRIUS ACT • For fastening on front plate or for installation in
3SU1 solid-state enclosure, see page 13/89
SIRIUS 3RA27 function modules
module
• For direct-on-line, reversing, and star-delta
(wye-delta) starting with IO-Link connection, Electronically configurable 8WD46 signaling
see page 3/101 onwards columns, 70 mm diameter
Motor starters for use in the control cabinet Signaling columns for IO-Link, with or without audible
signal
SIRIUS 3RA64, 3RA65 compact starters for IO-Link for
high-feature applications • Configuration of signaling column via IO-Link interface
(IODD)
• 3RA64 direct-on-line starters, see page 8/67
• Fast connection of signaling columns to application
• 3RA65 reversing starters, see page 8/68
using 4-pole M12 plugs
Infeed system for 3RA6, see page 8/76 onwards • Via the IO-Link interface, the pattern, color and
SIRIUS 3RA64
direct-on-line Accessories, see page 8/69 onwards brightness of the individual segments
starter (9 to 15 segments) can be set.
• The audible signal can also be set (volume, type of
Contactors with IO-Link 8WD46 signaling sound up to 105 dB).
column for IO-Link
Overload relays See page 13/163 onwards
SIRIUS 3RB24 electronic overload relays for IO-Link for 8WD44 signaling columns, 70 mm diameter
high-feature applications
• Up to five signaling elements can be connected using
• Evaluation modules an IO-Link adapter element
• Current measuring modules from 0.3 to 630 A • 24 V DC, diameter 70 mm
• In connection with contactors: Controlling direct-on- • Connection with bayonet mechanism
SIRIUS 3RB24 line, reversing and star-delta (wye-delta) starters via • For fastening on feet, 8WD44
overload relay IO-Link • Connection elements with screw or spring-loaded
• Full motor protection terminals or connection element with 5-pole M12 plug
• Diagnostics and current value transmission via IO-Link
See page 13/170 onwards
See page 7/127 onwards
8WD44 8WD44
signal- IO-Link
ing col- adapter
umn element

2/94 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
IO-Link
Introduction
System components
IO-Link RFID systems IO-Link software
SIMATIC RF200 RFID system in the HF range S7-PCT (Port Configuration Tool)
SIMATIC RF210R, SIMATIC RF220R, SIMATIC RF240R, Engineering software for configuring the IO-Link master
SIMATIC RF250R, SIMATIC RF260R products modules for SIMATIC S7-1200, ET 200SP, ET 200MP,

2
• Simple identification tasks such as reading an ET 200pro, ET 200eco PN and ET 200AL
ID number (UID) • Available as a stand-alone version or integrated into
• Reading of user data S7-PCT STEP 7 (V5.5 SP1 and higher) and TIA (V12 and higher)
RFID system • Writing of user data • Engineering of the IO-Link devices connected to the
for IO-Link • No RFID-specific programming, ideal for those new master
to RFID • Monitoring of the process image of the IO-Link devices
• Simple connection via master modules for IO-Link, • Open interface for importing further IODDs
such as SIMATIC S7-1200, ET 200SP, ET 200pro, • Freely available for download from
ET 200eco PN and ET 200AL Industry Online Support, see
• Use with the tried and tested ISO 15693 transponders https://support.industry.siemens.com/cs/ww/en/view/32469496
(MDS xxx) Library for IO-Link (LIOLink)
See Catalog ID 10
This library provides blocks and PLC data types to
IO-Link Device Description (IODD) enable communication between the SIMATIC controller
IODD files and the IO-Link master or IO-Link device.
These files provide the device description for IO-Link • Freely available for download from
devices. Industry Online Support, see
https://support.industry.siemens.com/cs/ww/en/view/82981502
• Comprehensive IODD catalog of SIEMENS IO-Link
devices Library for
• Freely available for download from IO-Link (LIOLink)
Industry Online Support, see WFB50001 Application of the device-specific blocks for IO-Link
IODD files for https://support.industry.siemens.com/cs/ww/en/ps/15851 "IO_LINK_DEVICE"
IO-Link EN END This application shows on a specific example how
REQ DONE_VALID
IODDfinder ID BUSY easy it is to connect Siemens IO-Link devices to
CAP ERROR
RD_WR STATUS a SIMATIC S7 CPU using the library for
The entire world of IO-Link under one roof PORT IOL_STATUS
IO-Link (LIOLink).
IOL_INDEX RD_LEN
The IODDfinder is a service provided by the IO-Link IOL_SUBINDEX
• Freely available for download from
IODDfinder for LEN

IC01_00467
community. It is a central cross-vendor database for RECORD_IOL_
Industry Online Support, see
IO-Link descriptive files (IODDs). In addition, the platform DATA
https://support.industry.siemens.com/cs/ww/en/view/90529409
provides an overview of the available IO-Link devices. IO-Link device
function block
For more information, see
https://ioddfinder.io-link.com/#/.

Siemens IC 10 · 2023 2/95


© Siemens 2023

Industrial communication
IO-Link
Introduction
IO-Link specification

■ Overview
Principles of the IO-Link specification Device data
According to the IO-Link specification, communication functions Device data can be parameters, identification data and
2

as follows: diagnostics information. Device data replacement is acyclic and


• Transmission takes place via an unshielded three-wire cable in response to an inquiry from the IO-Link master. Device data
no more than 20 m long, of the kind normally used for standard can be written into the device (Write) and also read from the
sensors. device (Read).
• Digital communication from 0 to 24 V on the so-called C/Q cable Events
• Most of the values transmitted are measured values from the When an event occurs, the device sends a signal to the master
sensors to report that an event is active. The master then reads out the
• The sensors and actuators are described by the event. Events can be fault messages (e.g. short circuit) and
IO Device Description (IODD) warnings/maintenance data (e.g. contamination, overheating).
Fault messages are transferred from the device via the IO-Link
• As a matter of principle, one IO-Link device can be connected master to the controller or HMI. The IO-Link master can also
to one IO-Link port of the master (point-to-point connection) transfer events and states. Events include, for example, open
• The transmission rates between IO-Link master and the circuit or communication breakdown.
devices are as follows:
- Via COM1: 4 800 Bd Device parameters and events are sent independently of the
- Via COM2: 38 400 Bd cyclic transmission of process data. The transmissions do not
- Via COM3: 230 400 Bd affect or impair each other.
• The average cycle time is 2 ms for the reading/writing of Data storage
16 data bits at a transmission rate of 38 400 Bd
As of specification V1.1, a data storage concept has been
IO-Link protocol created for IO-Link. In this concept, the IO-Link device initiates
storage of its data on a higher-level parameter server. In the
The IO-Link protocol supports both the Standard IO mode event that a device is replaced, the parameter server can restore
(SIO) and the IO-Link communications mode (COM). the original parameterization. It is therefore possible to replace
the devices without reparameterization.
Interface hardware: The IO-Link master contains the parameter server.
Compatible with sensors according to IEC 60947-5-2 and actuators The parameter server can also be implemented centrally
Communication and switching possible alternately in the PLC or in a system server. In this case the data must
be downloaded to the control system by means of the function
IO-Link master IO-Link device blocks provided.
L+
IO-Link masters
SIO COM
Standard IO Serial, The IO-Link master is the interface to higher-level control
switching bidirectional systems. The IO-Link master presents itself to the fieldbus as
operation communication a normal fieldbus node, and is integrated into the appropriate
1 network configurator via the relevant device description
2 4 SIO/IO-Link (GSD file).
C/Q
3
IO Device Description (IODD)
IC01_00176a

The IO Device Description (IODD) has been defined to provide


L– a full, transparent description of system characteristics as far as
the IO-Link device.
The structure of the protocol and its message frames depends on the The IODD contains information on communication
types of data to be transmitted. characteristics, device parameters, identification, process
and diagnostics data, and is supplied by the manufacturer.
Data types The design of the IODD is the same for all devices from all
The IO-Link specification makes a distinction between the manufacturers, and is always presented in the same way by the
following data types: IODD Interpreter Tools. This therefore ensures that the handling
is the same for all IO-Link devices, whatever the manufacturer.
Process data
New in IO-Link specification V1.1
The process data of the devices are transferred cyclically in
a data frame, with the process data width defined by the device. The IO-Link specification is currently available in Version 1.1,
Process data of 0 to 32 bytes are possible per device (input and and standardized in accordance with IEC 61131-9.
output in each case). The consistency width of the transmission
is not fixed and therefore depends on the master. Specification V1.1 offers the following new features compared
with the previous specification V1.0:
Value status • Transmission of up to 32 bytes of process data in one cycle
Each port has a value status (PortQualifier). The value status • Parameter server function
indicates whether the process data are valid or invalid. The value
status can be transferred cyclically with the process data.

2/96 Siemens IC 10 · 2023


© Siemens 2023

Industrial communication
IO-Link
Masters
IO-Link master module for S7-1500 > CM 8xIO-Link

■ Overview ■ Design
• Fastening to the S7-1500 DIN rail with a single screw
• 40-pole front connector, optionally with screw terminals or

2
push-in terminals
• Front connector with expandable cable compartment
• Included in the scope of supply:
- One U connector
- Front door

■ Function
Overview of functions
• Suitable for connecting up to 8 IO-Link devices (three-wire
connection) or 8 standard sensors
• IO-Link master according to IO-Link specification V1.1
• Data transmission rates COM1 (4.8 kBd), COM2 (38.4 kBd),
COM3 (230.4 kBd)
• Parameterizable diagnostics can be set for each channel
CM 8xIO-Link master • Master backup with "IO_Link_MASTER_8" function block
• Communications module for connecting up to 8 IO-Link • Replacement of the IO-Link device (for V1.1 devices only)
devices (three-wire connection) or 8 standard sensors
• Support for firmware updating of IO-Link devices
• Can be used directly downstream of an S7-1500 CPU or
distributed in ET 200MP via PROFINET or PROFIBUS • Variable address range for I/O data with up to 240 byte inputs
and 240 byte outputs;
• Powerful diagnostics functions facilitate preventive expansion limits:
maintenance to avoid plant standstills - Max. 32 bytes of input data and 32 bytes of output data
• Simple replacement of sensors/actuators without time- per port
consuming parameterization - Max. 240 bytes of input data and 240 bytes of output data
per module
■ Application • Port Qualifier Information (PQI)
IO-Link makes it easy to change the parameters for manu- • IO-Link port configuration with S7-PCT
facturing and processing different product versions and • IO-Link port configuration with STEP 7 or GSD (without S7-PCT)
batches, even during CPU runtime, down to the sensor/actuator • Standard system functions of SIMATIC ET 200MP:
level. Easy, much more detailed diagnostics are also possible - Identification and maintenance data IM0
down to the sensor or actuator, including remote diagnostics. - Firmware update
The CM 8xIO-Link enables direct connection of up to 8 IO-Link - Unequivocal, front-side module inscription
devices directly to SIMATIC S7-1500 and ET 200MP. This makes
external stations unnecessary.
■ Configuration
This results in savings on wiring, engineering and commissioning,
because everything can be configured centrally with the CPU. The SIMATIC S7-1500 IO-Link master of the S7-1500 can be
conveniently configured using the graphical user interface in the
free S7 Port Configuration Tool (S7-PCT, V3.5 and higher, SP1).
In addition to this configuration, commissioning without S7-PCT
is also possible. In this case, the port is configured by means of
either the TIA Portal or GSD file. The following port modes are
supported:
• Operation in "IO-Link autostart" mode (default)
• Operation in "IO-Link manual" mode
• Operation as DI
• Deactivated

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

CM 8xIO-Link communications module 6ES7547-1JF00-0AB0 1 1 unit 219


Communications module for connecting up to 8 IO-Link
devices (three-wire connection) or 8 standard sensors

6ES7547-1JF00-0AB0
For more information, see https://mall.industry.siemens.com/mall/en/ww/Catalog/Products/10355273.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/97
© Siemens 2023

Industrial communication
IO-Link
Masters
IO-Link master module for S7-1200 > SM 1278 4xIO-Link master

■ Overview ■ Design
• Expansion limits
- Cable length: Max. 20 m
- Max. 32 bytes of input data and 32 bytes of output data
2

per port
- Max. 32 bytes of input data and 32 bytes of output data
per module
LED displays
• DIAG: Operating state display (green/red) of the module
• C1..C4: Port status display (green) for ports 1, 2, 3 and 4
• Q1..Q4: Channel status display (green) for ports 1, 2, 3 and 4
• F1..F4: Port error display (red) for ports 1, 2, 3 and 4
Depending on the CPU type used, up to 8 SM 1278 units can be
used on one S7-1200 CPU.

■ Function
Supported functions
SM 1278 4xIO-Link master • I&M identification data
Module for connecting up to four IO-Link devices in accordance • Firmware update
with the IO-Link specification V1.1. The IO-Link parameters are • SIO Mode (standard IO mode)
configured by means of the Port Configuration Tool (PCT) with
• IO-Link parameter assignment with the S7-PCT interface
version V3.2 and higher.
configuration tool, TIA Portal from V13 and an
S7-1200 CPU V4.0 or higher
■ Application Supported data transmission rates
The SM 1278 module enables an exchange of data with up to • COM1 (4.8 kBd)
four external IO-Link devices through one three-wire cable each
or four standard actuators or standard encoders. Control can • COM2 (38.4 kBd)
be flexibly adapted to the communication partners using the • COM3 (230.4 kBd)
comprehensive parameter assignment options. Since IO-Link
is compatible with standard sensors, commercially available
sensors compliant with IEC 61131 Type 1 can also be operated
on the IO-Link master.

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

SM 1278 4xIO-Link master signal module 6ES7278-4BD32-0XB0 1 1 unit 212


For connecting up to four IO-Link devices in accordance
with the IO-Link specification V1.1

6ES7278-4BD32-0XB0

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Terminal block (spare part)


7-pole, tin-plated; 4 units
• Screw terminals 6ES7292-1AG30-0XA0 1 4 units 212
• Push-in terminals 6ES7292-2AG30-0XA0 1 4 units 212

6ES7292-1AG30-0XA0
For more information, see https://mall.industry.siemens.com/mall/en/ww/Catalog/Products/10231178.

* You can order this quantity or a multiple thereof.


2/98 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
IO-Link
Masters
IO-Link master module for ET 200SP > CM 4xIO-Link V1.1 Standard

■ Overview
• ET 200SP system functions supported
- Exchange of IO-Link device parameters (V1.1 devices only)
and of IO-Link master parameters without a PG including

2
automatic backup recovery without an engineering tool by
means of redundant parameter storage on the e-coding
element
- Reparameterization during ongoing operation
- I&M identification data
- Firmware update
- PROFIenergy
• Can be plugged onto type A0 BaseUnits (BU) with automatic
e-coding
• LED displays
- DIAG: Operating state display (green/red) of the module
- C1..C4: Port status display (green) for ports 1, 2, 3 and 4
- Q1..Q4: Channel status display (green) for ports 1, 2, 3 and 4
- F1..F4: Port error display (red) for ports 1, 2, 3 and 4
CM 4xIO-Link - PWR: Supply voltage display (green)
• CM 4xIO-Link communications module • Informative front-side module inscription
Serial communications module for connecting up to - Plain-text marking of the module type and function class
four IO-Link devices in accordance with the IO-Link - 2D matrix code (article and serial number)
specification V1.0 and V1.1. The IO-Link parameters are - Circuit diagram
configured by means of the Port Configuration Tool (PCT) - CM module class color coding: Silver
with version V3.0 and higher. - Hardware and firmware version
• Time-based IO - Complete article number
Time-based IO ensures that signals are output with a precisely • Optional accessories
defined response time. By combination of inputs and outputs, - Labeling strips
products passing by, for example, can be measured exactly - Reference identification label
or liquids can be perfectly dosed. - Color-coded label with color code CC04
• Supported data transmission rates • Optional system-integrated shield connection
- COM1 (4.8 kBd)
- COM2 (38.4 kBd)
- COM3 (230.4 kBd)
• Expansion limits
- Cable length: Max. 20 m
- Max. 32 bytes of input data and 32 bytes of output data
per port
- Max. 144 bytes of input data and 128 bytes of output data
per module

■ Application
• The CM 4xIO-Link communications module enables an • Since IO-Link is compatible with standard sensors,
exchange of data with up to 4 external IO-Link devices commercially available sensors compliant with IEC 61131
through one three-wire cable each. Type 1 can also be operated on the IO-Link master.
• Control can be flexibly adapted to the communication
partners using the comprehensive parameter assignment
options.

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

CM 4xIO-Link V1.1 Standard communications module 6ES7137-6BD00-0BA0 1 1 unit 255


• Serial communications module for connecting up to
4 IO-Link devices, time-based IO, BU type A0,
color code CC04

6ES7137-6BD00-0BA0
For more information, see https://mall.industry.siemens.com/mall/en/ww/Catalog/Products/10205200.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/99
© Siemens 2023

Industrial communication
IO-Link
Masters
IO-Link master module for ET 200pro > 4 IO-Link HF

■ Overview
• 45-mm-wide 4 IO-Link HF solid-state module
• 4 IO-Link ports according to IO-Link specification V1.1
2

• Port class B
• The IO-Link parameters are configured using the Port
Configuration Tool (S7-PCT), version V3.4 and higher

4 IO-LINK HF

■ Application
The 4 IO-Link HF solid-state module enables the exchange of Since IO-Link is compatible with standard sensors, commercially
data with up to 4 IO-Link devices. available sensors compliant with IEC 61131 Type 1 can also be
operated on the IO-Link master.

■ Design
The 4 IO-Link HF solid-state module is used together with the IO-Link devices (e.g. sensors) with a class A port are
CM IO-LINK 4 X M12 P connection module. Sensors and interconnected by means of a three-wire cable. IO-Link devices
actuators are integrated using commercially available 3- or that require an additional supply voltage and have a class B port
5-pole M12 plugs on the CM IO-Link 4 X M12 P. (e.g. actuators) are interconnected by means of a five-wire cable.

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

4 IO-Link HF solid-state module 6ES7147-4JD00-0AB0 1 1 unit 250


• 4 IO-Link ports according to IO-Link specification V1.1
• Port class B
• High Feature
• Channel diagnostics
• Including bus module
• Connection module must be ordered separately

6ES7147-4JD00-0AB0

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

CM IO-LINK 4 X M12 P connection module 6ES7194-4CA20-0AA0 1 1 unit 250


4 M12 sockets for connection of IO-Link devices to
ET 200pro 4 IO-Link HF solid-state module
Module labeling plates 6ES7194-4HA00-0AA0 1 500 units 250
For color coding of CM IOs in the colors white, red,
blue and green; pack of 100
M12 sealing caps 3RX9802-0AA00 100 10 units 42C
For protection of unused M12 terminals on ET 200pro
For more information, see https://mall.industry.siemens.com/mall/en/ww/Catalog/Products/10304039.

* You can order this quantity or a multiple thereof.


2/100 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
IO-Link
Masters
IO-Link master module for ET 200eco PN > IO-Link master modules

■ Overview
IO-Link master with 2 x M12-L coded power connector and
45-mm width

2
• IO-Link communications modules for connecting up to
8 IO-Link devices
• IO-Link master with 4 x port class A and 4 x port class B and
additional 4 digital inputs
• The IO-Link specifications V1.0 and V1.1 are supported.
IO-Link master with 2 x M12-A coded power connector and
30-mm width
• IO-Link communications modules for connecting up to
4 IO-Link devices
• IO-Link master with 4 x port class B
• The IO-Link specifications V1.0 and V1.1 are supported.
IO-Link master with 2 x M12-A coded power connector
and 60-mm width
• IO-Link communications modules for connecting up to
4 IO-Link devices
ET 200eco PN IO-Link master modules • IO-Link master with 4 x port class A and additional 8 digital
inputs and 4 digital outputs
• The IO-Link specification V1.0 is supported.

■ Application
IO-Link enables easy integration of sensors and actuators Since IO-Link is compatible with standard sensors,
from different manufacturers. ET200eco PN IO-Link master commercially available sensors compliant with IEC 61131
I/O devices enable an exchange of data with up to 4 or 8 IO-Link Type 1 can also be operated on the IO-Link master.
devices. With a high degree of protection, ruggedness and small
IO-Link devices (e.g. sensors) with a class A port are inter- dimensions, the IO-Link master I/O devices are especially well-
connected by means of a three-wire cable. IO-Link devices that suited for use at the machine level in confined spaces. They
require an additional supply voltage and have a class B port have adjustable parameters and diagnostics functions and can
(e.g. actuators) are interconnected by means of a five-wire cable. therefore be flexibly adapted to individual process requirements.

■ Function
In addition to the general functions of the ET 200eco PN • Expansion limits
I/O system, the IO-Link masters according to the IO-Link - Cable length to the IO-Link device: Max. 20 m
specification V1.1 have some further functions: - Max. 32 bytes of input data and 32 bytes of output data
• Supported data transmission rates of the IO-Link per IO-Link port
communication • Automatic backup of device parameters when the
- COM1 (4.8 kBd) IO-Link device is replaced (V1.1 devices only)
- COM2 (38.4 kBd) • Reparameterization of the device during operation using
- COM3 (230.4 kBd) a PLC function block
• Master backup using a PLC function block
• Support for firmware updates of IO-Link devices
• Configuration using a GSD file or S7-PCT

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

ET_200eco PN IO-Link master


• 4 IO-L + 8 DI + 4 DO, 24 V DC/1.3 A; 6ES7148-6JA00-0AB0 1 1 unit 257
8 x M12, degree of protection IP67, enclosure width 60 mm;
for connecting up to 4 IO-Link devices according to IO-Link
specification V1.0 and port class A as well as an additional
8 digital inputs and 4 digital outputs
• 4 IO-L; 6ES7148-6JD00-0AB0 1 1 unit 257
4 x M12, degree of protection IP67, enclosure width 30 mm;
for connecting up to 4 IO-Link devices according to IO-Link
specifications V1.0 and V1.1 and port class B
6ES7148-6J.00-0.B0 • 8 IO-L + 4 DI 24 V DC; 6ES7148-6JG00-0BB0 1 1 unit 257
8 x M12, degree of protection IP67, enclosure width 45 mm;
for connecting up to 8 IO-Link devices according to IO-Link
specifications V1.0 and V1.1, 4 x port class A + 4 x port class B
as well as an additional 4 digital inputs
For more information, see https://mall.industry.siemens.com/mall/en/ww/Catalog/Products/10370454.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/101
© Siemens 2023

Industrial communication
IO-Link
Masters
IO-Link master module for ET 200AL > CM IO-Link

■ Overview • A power supply connection with M8 connection technology


with loop-through
• LED display for port status
• LED display for channel status in SIO mode
2

• LED display for module status (DIAG)


• LED display for load voltage 2L+ (PWR)
• Labeling plates for channel, module and slot identification
• Integrated cable tie holder
• Meaningful module inscription on front panel:
- Plain text marking of module type
- Interface marking
- LED label
• Meaningful module inscription on side panel:
- Article number, function level and FW version
- 2D matrix code (article and serial number)
- Pin assignments of all interfaces
CM IO-Link communications module
• CM IO-Link communications module, 30 mm wide Labeling plates for channel, module and slot identification
are supplied with the modules. These labeling plates can be
• For connecting up to 4 IO-Link devices in accordance with the inscribed using commercially available inscription machines.
IO-Link specifications V1.0 and V1.1 and port class B
• The IO-Link parameters are configured by means of the
S7-PCT Port Configuration Tool with version V3.2 and higher.
■ Function
• IO-Link master according to IO-Link specification V1.1
■ Application • 4 ports, class B type
The CM IO-Link communications module supports data • Supported data transmission rates
exchange between up to four IO-Link devices. IO-Link devices - COM1 (4.8 kBd)
(e.g. sensors) with a class A port are interconnected by means - COM2 (38.4 kBd)
of a three-wire cable. IO-Link devices, which require an - COM3 (230.4 kBd)
additional supply voltage and have a class B port (e.g. • Expansion limits
actuators), are interconnected by means of a five-wire cable. - Cable length: Max. 20 m
Since IO-Link is compatible with standard sensors, - Max. 32 bytes of input data and 32 bytes of output data
commercially available sensors compliant with IEC 61131 per port
Type 1 can also be operated on the IO-Link master. - Max. 32 bytes of input data and 32 bytes of output data
per module
The 30-mm-wide I/O modules are ideally suited for use in • Automatic backup of device parameters when the IO-Link
extremely confined spaces. They have adjustable parameters device is replaced (V1.1 devices only)
and diagnostics functions and can therefore be flexibly adapted
to individual process requirements. • Reparameterization during ongoing operation
• Standardized display and diagnostics concept:
The following IO-Link masters are available:
- Port status display (port activated or deactivated, green LED)
• CM 4xIO-Link communications modules, 4XM12 - Channel status display for signal state in SIO mode
(green LED)
■ Design - Module status display (DIAG, red/green LED)
- Display for monitoring the load voltage 2L+ (PWR, green LED)
The I/O modules have a screw mounting hole at the front and
side, and can be mounted in any position. As a result, they are • Supported functions:
extremely flexible to install on either a level surface or on - Detailed module-level diagnostics and diagnostic interrupt
aluminum mounting rails using sliding blocks. - Identification and maintenance data IM0 ... IM3
- Firmware update
The CM IO-Link communications module features: - PROFIenergy
• A backplane bus connection (ET connection) with
M8 connection technology for connection to an interface
module or other I/O modules

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

CM IO-Link 6ES7147-5JD00-0BA0 1 1 unit 254


CM 4x IO-Link, 4x M12;
for connecting up to 4 IO-Link devices in accordance with
the IO-Link specifications V1.0 and V1.1 and port class B

6ES7147-5JD00-0BA0
For more information, see https://mall.industry.siemens.com/mall/en/ww/Catalog/Products/10233997.
* You can order this quantity or a multiple thereof.
2/102 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Industrial communication
IO-Link
IO-Link digital modules
IO-Link I/O modules

■ Overview
The IO-Link communication standard enables and standardizes
communication between machine and plant control systems on
one hand and sensors, actuators and other field devices on

2
the other.
The IO-Link I/O modules permit simple connection of binary
standard sensors and actuators and the signals and power
supply are transmitted via IO-Link (IO-Link master).
The IO-Link IO modules can be connected to any IO-Link master
and distributed I/O units that are independent of the fieldbus can
be built. The universal deployability of the IO-Link DIQ I/O
modules provides additional versatility.
With the ET 200AL IO-Link I/O modules, a rounded portfolio of
digital input, digital output and digital input/output modules is
available in the design and with the ET 200AL system features.

IO-Link I/O modules

■ Application
IO-Link can provide advantages as a communications system, I/O station, with which distributed signals can be detected and
e.g. when complex sensors and actuators are to be used. These output in the plant or machine.
IO-Link devices can be connected via an IO-Link master and be
integrated into the automation system with reduced effort, The following IO-Link I/O modules are available:
e.g. for cabling. • IO-Link, digital input module DI 8 x 24 V DC, 8 x M8
• IO-Link, digital input module DI 16 x 24 V DC, 8 x M12
If such an IO-Link master is available, further binary
sensor/actuator signals can be integrated in the field via the • IO-Link, digital output module DQ 8 x 24 V DC/2 A, 8 x M12
IO-Link I/O modules without great effort. IO-Link masters can • IO-Link, digital input/output module
be expanded with the IO-Link I/O modules to form a modular DIQ 4+DQ 4 x 24 V DC/0.5 A
• IO-Link, digital input/output module DIQ 16 x 24 V DC/0.5 A

■ Function
• Standardized display and diagnostics concept: Engineering
- Channel status display for signal status log. "0" and log. "1"
(green LED) The engineering of the IO-Link I/O modules is performed
- Module status display (DIAG, red/green LED) via IO-Link engineering of the relevant IO-Link master.
- Display for monitoring the load voltage 2L+ (PWR, green LED, For this purpose, one device description file (IODD)
only modules with outputs) per IO-Link I/O module is provided.
• Supported functions:
- Channel-specific parameterization
- Detailed module-level diagnostics and diagnostic interrupt
- Safety-related tripping of digital outputs according to
IEC 62061 (SILCL2) and ISO 13849-1 (Cat 3/PL d)
- IO-Link V1.1
- Support for the "general profile" of IO-Link
- Firmware update

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

IO-Link, digital input modules


Degree of protection IP67
• DI 8 x 24 V DC, 8 x M8 6ES7141-5BF00-0BL0 1 1 unit 250
• DI 16 x 24 V DC, 8 x M12 6ES7141-5AH00-0BL0 1 1 unit 250
IO-Link, digital output modules
Degree of protection IP67
• DQ 8 x 24 V DC/2 A, 8 x M12 6ES7142-5AF00-0BL0 1 1 unit 250
IO-Link, digital input/output modules
6ES714.-5..00-0BL0 Degree of protection IP67
• DIQ 4+DQ 4 x 24 V DC/0.5 A, 8 x M8 6ES7143-5BF00-0BL0 1 1 unit 250
• DIQ 16 x 24 V DC/0.5 A, 8 x M12 6ES7143-5AH00-0BL0 1 1 unit 250

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 2/103
© Siemens 2023

Industrial communication
IO-Link
IO-Link digital modules
IO-Link I/O modules

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)
2

Control connecting cables


M12-180/M12-180
Flexible 5-core cable, assembled with an A-coded,
5-pole M12 plug and A-coded, 5-pole M12 socket, both
ends with a straight cable outlet, for connecting IO-Link
sensors/actuators
6XV1801-2C... • Cable length 1 m 6XV1801-2CH10 1 1 unit 5K2
• Cable length 5 m 6XV1801-2CH50 1 1 unit 5K2
• Cable length 15 m 6XV1801-2CN15 1 1 unit 5K2
Power connecting cables
M12-90/M12-90
Flexible 4-core power supply cable, assembled with an
L-coded 4-pole M12 plug and L-coded,
4-pole M12 socket, both ends with 90° angled connectors,
for the 24-V DC device power supply
6XV1801-6GH50
• Cable length 5 m 6XV1801-6GH50 1 1 unit 5K1
M12 connector
Can be assembled, for connecting actuators or sensors,
5-pole, screw connection, max. 0.75 mm², A-coded,
3RK1902-4BA00-5AA0 max. 4 A
• Straight 3RK1902-4BA00-5AA0 1 1 unit 42D
• Angled 3RK1902-4DA00-5AA0 1 1 unit 42D

3RK1902-4DA00-5AA0
Control cable
Assembled at one end with 1 x M12 angled plug, 5-pole,
5 x 0.34 mm², A-coded, max. 4 A, PUR sheath, black
3RK1902-4H...-5AA0 • Cable length 5 m 3RK1902-4HB50-5AA0 1 1 unit 42D
• Cable length 10 m 3RK1902-4HC01-5AA0 1 1 unit 42D
AS-Interface sealing caps
• For free M12 sockets 3RK1901-1KA00 100 10 units 42C
• For free M8 sockets 3RK1901-1PN00 100 10 units 42C

3RK1901-1KA00

3RK1901-1PN00
For more information, see https://mall.industry.siemens.com/mall/en/ww/Catalog/Products/10383153.

* You can order this quantity or a multiple thereof.


2/104 Siemens IC 10 · 2023 Illustrations are approximate
3
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors

Price groups
PG 41B, 41E, 41H, 42F

3/2 Introduction

Power contactors for switching


motors
3/8 General data

3
3/18 SIRIUS 3RT contactors, 3-pole
up to 250 kW
Accessories for SIRIUS 3RT contactors
and SIRIUS 3RH2 contactor relays
3/69 - General data
3/81 - Auxiliary switches, instantaneous
NEW NEU

3/95 - Auxiliary switches, delayed


3/97 - Surge suppressors
3/99 - Modules for contactor control
3/104 - Link modules
3/109 - Connection modules/adapters
3/112 - Covers
3/113 - Miscellaneous accessories
Spare parts for SIRIUS 3RT contactors
and SIRIUS 3RH2 contactor relays
3/116 - Solenoid coils
3/119 - Contacts and arc chutes
3/120 SIRIUS 3RT12 and 3TF6 vacuum
contactors
3/133 Accessories and spare parts for
SIRIUS 3RT12 and 3TF6 vacuum
contactors
3/138 3TG10 power relays/miniature contactors

Reversing contactor assemblies


3/142 SIRIUS 3RA23 reversing contactor
assemblies, up to 55 kW
3/153 Reversing contactor assemblies
consisting of SIRIUS 3RT1 and 3TF6
contactors, up to 335 kW

Contactor assemblies for star-delta


(wye-delta) starting
3/158 SIRIUS 3RA24 contactor assemblies
for star-delta (wye-delta) starting,
up to 90 kW
3/171 Contactor assemblies for star-delta
(wye-delta) starting consisting of
SIRIUS 3RT and 3TF6 contactors,
up to 710 kW

Siemens IC 10 · 2023
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors

Introduction

■ Overview
AC-3/AC-3e

AC-3e

le
3

po
3-
3RT12 3TF6
500 A/250 kW 820 A/450 kW
AC-3/AC-3e

AC-3e

le
po
3-
3RT20 3RT10
110 A/55 kW 500 A/250 kW
AC-1

le
po
3-
3RT24 3RT14
160 A 690 A 2 650 A
AC-1

le
po
4-
3RT23 3RT13
160 A 525 A
AC- 6b

le
po
3-

3RT26
151 A/100 kvar
AC-3

IC01_00563b
le
po
4-

3RT25
80 A/37 kW

Overview of the 3RT and 3TF contactors

3/2 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors

Introduction

More information
Homepage, see www.siemens.com/sirius Conversion tool, see www.siemens.com/conversion-tool
Industry Mall, see www.siemens.com/product?3RT_3TK_3TC TIA Selection Tool Cloud (TST Cloud), see
www.siemens.com/tstcloud/?node=Contactor

3
Size S00 S0
Type 3RT201 3RT202
3RT20 contactors
Type 3RT2015 3RT2016 3RT2017 3RT2018 3RT2023 3RT2024 3RT2025 3RT2026 3RT2027 3RT2028
AC, DC operation (p. 3/47, 3/52 ... 3/55) (p. 3/48, 3/49, 3/56 ... 3/58, 3/60)
AC-3 and AC-3e
Ie/AC-3/AC-3e/400 V A 7 9 12 16 9 12 17 25 32 38
400 V kW 3 4 5.5 7.5 4 5.5 7.5 11 15 18.5
230 V kW 1.5 2.2 3 4 2.2 3 4 5.5 7.5 11
500 V kW 6 7.7 9.2 12.4 9 12 17 18 32 32
690 V kW 4 5.5 5.5 7.5 7.5 7.5 11 11 18.5 18.5
1 000 V kW -- -- -- -- -- -- -- -- -- --
AC-4 (at Ia = 6 x Ie)
400 V kW 3 4 4 5.5 4 5.5 7.5 7.5 11 11
400 V (200 000 operating cycles) kW 1.15 2 2 2.5 2 2.6 3.5 4.4 6 6
AC-1 (40 °C,  690 V)
Ie A 18 22 22 22 40 40 40 40 50 50

Accessories for contactors


Auxiliary • On the front 3RH29, 3RA28 (p. 3/87 ... 3/95) 3RH29, 3RA28 (p. 3/87 ... 3/95)
switches • Lateral 3RH29 (p. 3/91 ... 3/94) 3RH29 (p. 3/91 ... 3/94)
Function • Direct-on-line 3RA281. (p. 3/100) 3RA281. (p. 3/100)
modules starting,
star-delta (wye-delta)
starting
• IO-Link, AS-Interface 3RA271.-.AA00 (p. 3/101, 3/102) 3RA271.-.AA00 (p. 3/101, 3/102)
Surge suppressors 3RT2916 (p. 3/97, 3/98) 3RT2926 (p. 3/97, 3/98)

3RU2 and 3RB3 overload relays


3RU thermal overload relays 3RU2116 0.11 ... 16 A (p. 7/89) 3RU2126 1.8 ... 40 A (p. 7/89)
3RB electronic overload relays
• For standard applications 3RB3016, 0.1 ... 16 A (p. 7/102 ... 7/104) 3RB3026, 0.1 ... 40 A (p. 7/102 ... 7/104)
3RB3113 3RB3123
• For High-Feature applications 3RB22, 3RB23 and 3RB24 (p. 7/125, 7/133) 3RB22, 3RB23 and 3RB24 (p. 7/125, 7/133)
with current measuring module with current measuring module
3RB2906-2.G1 (p. 7/137) 3RB2906-2.G1 (p. 7/137)
0.3 ... 25 A 0.3 ... 25 A

3RV20 motor starter protectors


Motor starter protectors 3RV2011 0.11 ... 16 A (p. 7/27) 3RV2021 0.45 ... 40 A (p. 7/28)
Link modules 3RA1921, 3RA2911 (p. 7/61) 3RA2921 (p. 7/61)

3RA23 reversing contactor assemblies


Complete units Type 3RA2315 3RA2316 3RA2317 3RA2318 -- 3RA2324 3RA2325 3RA2326 3RA2327 3RA2328
(p. 3/149) (p. 3/150)
400 V kW 3 4 5.5 7.5 5.5 7.5 11 15 18.5
Assembly kits/wiring modules 3RA2913-2AA. (p. 3/104) -- 3RA2923-2AA. (p. 3/104)
Function modules 3RA271.-.BA00 (p. 3/101) -- 3RA271.-.BA00 (p. 3/101)

3RA24 contactor assemblies for star-delta (wye-delta) starting


Complete units Type 3RA2415 3RA2416 3RA2417 3RA2423 3RA2425 3RA2426
(p. 3/167) (p. 3/168)
400 V kW 5.5 7.5 11 11 15/18.5 22
Assembly kits/wiring modules 3RA2913-2BB. (p. 3/105) 3RA2923-2BB. (p. 3/105)
Function modules 3RA271.-.CA00 (p. 3/101) 3RA271.-.CA00 (p. 3/101)

Note:
Safety characteristics for contactors, see "Standards and
approvals", page 16/9.

Siemens IC 10 · 2023 3/3


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors

Introduction
3

Size S2 S3
Type 3RT203 3RT204
3RT20 contactors
Type 3RT2035 3RT2036 3RT2037 3RT2038 3RT2045 3RT2046 3RT2047
AC, DC operation (p. 3/50, 3/59, 3/61) (p. 3/51, 3/59, 3/63)
AC-3 and AC-3e
Ie/AC-3/AC-3e/400 V A 41 50 65 80 80 95 110
400 V kW 18.5 22 30 37 37 45 55
230 V kW 11 15 18.5 22 22 22 30
500 V kW 41 51 65 80 80 95 110
690 V kW 22 22 37 45 55 75 90
1 000 V kW -- -- -- -- 37 37 37
AC-4 (at Ia = 6 x Ie)
400 V kW 18.5 22 30 37 37 45 55
400 V (200 000 operating cycles) kW 11.6 12.6 14.7 15.8 17.9 22 24.3
AC-1 (40 °C,  690 V)
Ie A 60 70 80 90 125 130 130
Accessories for contactors
Auxiliary • On the front 3RH29, 3RA28 (p. 3/87 ... 3/95) 3RH29, 3RA28 (p. 3/87 ... 3/95)
switches • Lateral 3RH29 (p. 3/91 ... 3/94) 3RH29 (p. 3/91 ... 3/94)
Function • Direct-on-line starting 3RA283. (p. 3/100) 3RA283. (p. 3/100)
modules • IO-Link, AS-Interface 3RA271.-.AA00 (p. 3/101, 3/102) 3RA271.-.AA00 (p. 3/101, 3/102)
Surge suppressors 3RT2936 (p. 3/97, 3/98) 3RT2936, 3RT2946 (p. 3/97, 3/98)
Terminal covers 3RT2936-4EA2 (p. 3/112) 3RT2946-4EA2 (p. 3/112)
3RU2 and 3RB overload relays
3RU thermal overload relays 3RU2136 11 ... 80 A (p. 7/90) 3RU2146 28 ... 100 A (p. 7/90)
3RB electronic overload relays
• For standard applications 3RB3036, 12.5 ... 80 A (p. 7/102 ... 7/104) 3RB3046, 12.5 ... 115 A (p. 7/102 ... 7/104)
3RB3133 3RB3143
• For High-Feature applications 3RB22, 3RB23 and 3RB24 (p. 7/125, 7/133) 3RB22, 3RB23 and 3RB24 (p. 7/125, 7/133)
with current measuring with current measuring
module 3RB2906-2JG1 (p. 7/137) module 3RB2906-2JG1 (p. 7/137)
10 ... 100 A 10 ... 100 A
3RV20 motor starter protectors
Motor starter protectors 3RV2031, 3RV2032 9.5 ... 80 A (p. 7/30) 3RV2041, 3RV2042 28 ... 100 A (p. 7/30)
Link modules 3RA2931 (p. 7/61) 3RA1941 (p. 7/61)
3RA23 reversing contactor assemblies
Complete units Type 3RA2335 3RA2336 3RA2337 3RA2338 3RA2345 3RA2346 3RA2347
(p. 3/151) (p. 3/152)
400 V kW 18.5 22 30 37 37 45 55
Assembly kits/wiring modules 3RA2933-2AA. (p. 3/104) 3RA2943-2AA. (p. 3/104)
Function modules 3RA271.-.BA00 (p. 3/101) 3RA271.-.BA00 (p. 3/101)
Mechanical interlocks 3RA2934-2B (p. 3/108) 3RA2934-2B (p. 3/108)
3RA24 contactor assemblies for star-delta (wye-delta) starting
Complete units Type 3RA2434 3RA2435 3RA2436 3RA2437 3RA2444 3RA2445 3RA2446
(p. 3/169) (p. 3/170)
400 V kW 22/30 37 45 55 55 75 90
Assembly kits/wiring modules 3RA2933-2BB./-2C (p. 3/105) 3RA2943-2BB./-2C (p. 3/105)
Function modules 3RA271.-.CA00 (p. 3/101) 3RA271.-.CA00 (p. 3/101)

Note:
Safety characteristics for contactors, see "Standards and
approvals", page 16/9.

3/4 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors

Introduction

3
Size S6 S10 S12
Type 3RT105 3RT1.6 3RT1.7
3RT10 contactors · 3RT12 vacuum contactors
Type 3RT1054 3RT1055 3RT1056 3RT1064 3RT1065 3RT1066 3RT1075 3RT1076
AC, DC operation (p. 3/64 ... 3/66) (p. 3/64 ... 3/66) (p. 3/64 ... 3/66)
Type -- -- -- 3RT1264 3RT1265 3RT1266 3RT1275 3RT1276
(p. 3/130) (p. 3/130)
AC-3 and AC-3e
Ie/AC-3/AC-3e/400 V A 115 150 185 225 265 300 400 500
400 V kW 55 75 90 110 132 160 200 250
230 V kW 37 45 55 55 75 90 132 160
500 V kW 75 90 132 160 160 200 250 315 (355)1)
690 V kW 110 132 160 On request On request On request 400 400 (500)1)
1 000 V kW 75 90 90 90 (315)1) 132 (355)1) 132 (400)1) 250 (560)1) 250 (710)1)
AC-4 (at Ia = 6 x Ie)
400 V kW 55 75 90 110 132 160 200 250
400 V (200 000 operating kW 29 38 45 54 (78)1) 66 (93)1) 71 (112)1) 84 (140)1) 98 (161)1)
cycles)
AC-1 (40 °C,  690 V)
Ie A 160 185 215 275 (330)1) 330 330 430 (610)1) 610
3RT14 AC-1 contactors
Type 3RT1456 (p. 4/17, 4/18) 3RT1466 3RT1467 (p. 4/17, 4/18) 3RT1476
Ie/AC-1/40 °C/ 690 V A 275 400 500 690
Accessories for contactors
Auxiliary • On the front 3RH19, 3RT1926 (p. 3/90, 3/96)
switches • Lateral 3RH19 (p. 3/92 ... 3/94)
Surge suppressors 3RT1956-1C (RC element) (p. 3/98)
Terminal covers 3RT1956-4EA. (p. 3/112) 3RT1966-4EA. (p. 3/112)
Box terminal blocks 3RT1955-4G, 3RT1956-4G (p. 3/110) 3RT1966-4G (p. 3/110)
3RB2 overload relays
3RB electronic overload relays
• For standard applications 3RB2056 50 ... 200 A (p. 7/114, 7/115) 3RB2066 55 ... 250 A or 160 ... 630 A
3RB2153 50 ... 200 A (p. 7/116) 3RB2163 55 ... 250 A or 160 ... 630 A
• For High-Feature applications 3RB22, 3RB23 and 3RB24 (p. 7/125, 7/133) 3RB22, 3RB23 and 3RB24 (p. 7/125, 7/133)
with current measuring with current measuring module
module 3RB2956-2TH2 (p. 7/137) 3RB2966-2WH2 (p. 7/137)
20 ... 200 A 63 ... 630 A
3VA2 molded case motor starter protectors
Molded case motor starter (See Catalog LV 10)
protectors
• for 3RT10 3VA21 3VA22 3VA22 3VA23 3VA23 3VA24 3VA24 3VA25
• for 3RT12 3VA21 3VA22 3VA22 3VA23 3VA23 3VA24 3VA24 3VA25
Reversing contactor assemblies2)
Complete units Type --
400 V kW 55 75 90 110 132 160 200 250
Assembly kits/wiring modules 3RA1953-2A (p. 3/104) 3RA1963-2A (p. 3/104) 3RA1973-2A (p. 3/104)
Mechanical interlocks 3RA1954-2A (p. 3/108)
Contactor assemblies for star-delta (wye-delta) starting2)
Complete units Type --
400 V kW --
Assembly kits/wiring modules 3RA1953-2B (p. 3/106) 3RA1963-2B (p. 3/106) 3RA1973-2B (p. 3/106)
1) Value applies for 3RT12 contactors. Note:
2)
Contactor assemblies for customer assembly:
- Reversing contactor assemblies, see pages 3/154 to 3/156, Safety characteristics for contactors, see "Standards and
- Contactor assemblies for star-delta (wye-delta) starting, approvals", page 16/9.
see pages 3/172 to 3/177.

Siemens IC 10 · 2023 3/5


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors

Introduction
3

Size 14 14
Type 3TF68 3TF69
3TF68/3TF69 vacuum contactors
Type 3TF68 3TF69
(p. 3/131, 3/132) (p. 3/131, 3/132)
AC-3 and AC-3e
Ie/AC-3/AC-3e/690 V A 630 820 (630)1)
400 V kW 335 450 (335)1)
230 V kW 200 260 (200)1)
690 V kW 600 800 (600)1)
1 000 V kW 600 800
AC-4 (at Ia = 6 x Ie)
400 V kW 355 400
400 V (200 000 operating kW 168 191
cycles)
AC-1 (40 °C,  690 V)
Ie A 700 910
Accessories for contactors
Auxiliary switches
• Lateral 3TY7561 (p. 3/133)
Surge suppressors 3TX7572 (p. 3/134)
Terminal covers 3TX7686, 3TX7696 (p. 3/134)
3RB2 overload relays
3RB electronic overload relays
• For standard applications 3RB2066, 55 ... 250 A (p. 7/114, 7/115) 3RB22, 3RB23 and 3RB24 (p. 7/125, 7/133)
3RB2163 or (p. 7/116) with current measuring module
160 ... 630 A 3RB2906-2.G1 (p. 7/137)
• For High-Feature applications 3RB22, 3RB23 and 3RB24 (p. 7/125, 7/133) with 3UF series transformer
with current measuring up to 820 A
module 3RB2966-2WH2 (p. 7/137)
63 ... 630 A 63 ... 820 A
3VA2 molded case motor starter protectors
Molded case motor starter 3VA25 (See Catalog LV 10)
protectors
Reversing contactor assemblies2)
Complete units Type --
400 V kW 335
Assembly kits/wiring modules 3TX7680-1A (p. 3/135)
Mechanical interlocks 3TX7686-1A (p. 3/135)
Contactor assemblies for star-delta (wye-delta) starting2)
Complete units Type --
400 V kW 710
Assembly kits/wiring modules 3TX7680-1B (p. 3/135)
1)
Value applies for utilization category AC-3e. Note:
2)
Contactor assemblies for customer assembly:
- Reversing contactor assemblies, see page 3/157, Safety characteristics for contactors, see "Standards and
- Contactor assemblies for star-delta (wye-delta) starting, see page 3/178. approvals", page 16/9.

3/6 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors

Introduction
Connection methods
The 3RT contactors are available with screw terminals (box
terminals or flat connectors) or with spring-loaded terminals.
The 3TG10 power relays/miniature contactors are available with
screw terminals or flat connectors.

Screw terminals

3
Type 3TG10 Spring-loaded terminals
3TG10 power relays/miniature contactors
Number of main contacts 4 Flat connectors
AC, DC operation (p. 3/138)
AC-1 The terminals are indicated in the corresponding
Ie at 400 V 55 °C A 20 tables by the symbols shown on orange backgrounds.
P at 400 V kW 13
Voltage data
At 230 V kW 7.5
AC-3 The data for 3-phase power systems according to IEC 60947-4-1
Ie up to 400 V A 8.4 are valid for the following line system configurations:
.

P at 400 V kW 4 Voltage data Line system configurations


AC-3e Ue Three-phase Three-phase
Ie up to 400 V A 6.4 four-wire systems three-wire systems
P at 400 V kW 3

IC01_00703

IC01_00709
V V V
230 -- 230
400 230/400 400
440 260/440 440
500 -- 500
690 400/690 690 (only from size S3)
1 000 -- 1 000
-- Not specified

Use of 3RT contactors, 3RT and 3TF vacuum contactors,


reversing contactor assemblies, and contactor assemblies
for star-delta (wye-delta) starting with IE3 and IE4 motors
Note:
For the use of 3RT contactors, 3RT and 3TF vacuum contactors,
reversing contactor assemblies and contactor assemblies
for star-delta (wye-delta) starting in conjunction with highly
efficient IE3 and IE4 motors, please observe the information on
dimensioning and configuring, see Application Manual.
For more information, see page 1/8.

Siemens IC 10 · 2023 3/7


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
General data

■ Overview
The SIRIUS family of controls
The SIRIUS modular system with its components for the
switching, starting, protection and monitoring of motors and
industrial systems stands for the fast, flexible and space-saving
construction of control cabinets.

3RT2.1 contactors · Size S00 with mountable accessories


3

The figure shows the version with screw terminals

11 13
12
14

17

2 1 16

19
1
6 2
7
8 18

IC01_00614d
3 4
5
9
17

14
15

10

1 Contactor, size S00

2 2-pole auxiliary switch, laterally mountable 12 Star jumper, 3-pole, without connecting terminal
3 1-pole auxiliary switch, for snapping onto the front, 13 Link for paralleling, 3-pole, with connecting terminal
cable entry from the top
14 Solder pin adapter
4 2-pole auxiliary switch, for snapping onto the front, 15 Connection module (adapter and connector) for contactors
cable entry from the bottom with screw terminals
5 4-pole auxiliary switch, for snapping onto the front 16 Safety main current connector for two contactors
6 3RA27 function module for AS-Interface Assembly kit 3RA2913-2AA1
7 3RA27 function module for IO-Link Consisting of:
8 3RA28 function module 17 Wiring modules on the top and bottom for connecting the main,
auxiliary and control current paths, electrical interlock 1)
9 Surge suppressor with/without LED
included, interruptible (NC contact interlock)
10 Cover, sealable
18 Mechanical interlocks 2)
11 3-phase infeed terminal
19 Two connecting clips for two contactors 2)

For contactors
For contactors and coupling contactors
1) 3RT201. contactors with one NC contact in the basic unit
are required for the electrical interlock. An additional NO contact
is required for momentary-contact operation.
2) The parts
18 and 19 can only be ordered together as 3RA2912-2H
mechanical connectors.

Accessories and spare parts, see pages 3/69 to 3/119.

3/8 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
General data
3RT2.2 contactors · Size S0 with mountable accessories
The figure shows the version with screw terminals

16
17
15
19

3
2 1
18 1
21 2

4
3 5

IC01_00615e
6
20

7
8
9

10
19

11 15

14
13

12

1 Contactor, size S0

2 2-pole auxiliary switch, laterally mountable 13 Link for paralleling, 3-pole, with connecting terminal
3 1-pole auxiliary switch, for snapping onto the front 14 Connection module (adapter and plug) for contactors
cable entry from the top with screw terminals
4 2-pole auxiliary switch, for snapping onto the front 15 Coil connection module, on the top or bottom
cable entry from the bottom 16 3-phase infeed terminal
5 4-pole auxiliary switch, for snapping onto the front 17 Link for paralleling (star jumper), 3-pole,
6 Pneumatically delayed auxiliary switch without connecting terminal
18 Safety main current connector for two contactors
7 3RA27 function module for AS-Interface
8 3RA27 function module for IO-Link Assembly kit 3RA2923-2AA1
Consisting of:
9 3RA28 function module
19 Wiring modules on the top and bottom for connecting the
10 Surge suppressor with/without LED main current paths, electrical interlock included
11 Mechanical latching block (NC contact interlock)
12 Cover, sealable 20 Mechanical interlocks 1)
21 Two connecting clips for two contactors 1)

For contactors
For contactors and coupling contactors
1)
The parts 20 and 21 can only be ordered together as 3RA2922-2H
mechanical connectors.

Accessories and spare parts, see pages 3/69 to 3/119.

Siemens IC 10 · 2023 3/9


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
General data
3RT2.3 contactors · Size S2 with mountable accessories
The figure shows the version with screw terminals

12
13
14
3

16

1
17
15
2 1
18

2
3 4
5

IC01_00616d
6
7

14 16
8

11
10

1 Contactor, size S2

2 2-pole auxiliary switch, laterally mountable 14 Coil connection module, top or bottom
3 1-pole auxiliary switch, for snapping onto the front, 15 Safety main current connector for two contactors
cable entry from the top
Assembly kit 3RA2933-2AA1
4 2-pole auxiliary switch, for snapping onto the front, Consisting of:
cable entry from the bottom
16 Wiring modules on the top and bottom for connecting the
5 4-pole auxiliary switch, for snapping onto the front main current paths, electrical interlock included
6 3RA27 function module for AS-Interface (NC contact interlock)
7 3RA27 function module for IO-Link 17 Two connecting clips for two contactors
8 3RA28 function module
To be ordered separately:
9 Surge suppressor with/without LED
18 Mechanical interlocks
10 Cover, sealable
11 Link for paralleling, 3-pole, with connecting terminal
12 3-phase infeed terminal For contactors
13 Link for paralleling (star jumper), 3-pole, For contactors and coupling contactors
without connecting terminal

Accessories and spare parts, see pages 3/69 to 3/119.

3/10 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
General data
3RT2.4 contactors · Size S3 with mountable accessories
The figure shows the version with screw terminals

16

15
14

3
13
17

18 1
19

2
10 2

IC01_00617d
3 4
5

6
7
9
17

8 13

12

11

1 Contactor, size S3

2 2-pole auxiliary switch, laterally mountable 12 Links for paralleling, 3-pole, with connecting terminal
3 1-pole auxiliary switch, for snapping onto the front, 13 Coil connection module, top or bottom
cable entry from the top
14 Links for paralleling (star jumper), 3-pole,
4 2-pole auxiliary switch, for snapping onto the front, without connecting terminal
cable entry from the bottom
15 Auxiliary conductor terminal, 3-pole
5 4-pole auxiliary switch, for snapping onto the front
16 Single-phase infeed terminals (3 units)
6 3RA27 function module for AS-Interface
7 3RA27 function module for IO-Link Assembly kit 3RA2943-2AA1
Consisting of:
8 3RA28 function module
17 Wiring modules on the top and bottom for connecting the main,
9 Surge suppressor with/without LED auxiliary and control current paths, electrical interlock1)
(Varistor, diode assembly), can be plugged in on the front included, interruptible (NC contact interlock)
10 Surge suppressor without LED (RC element), can be 18 Two connectors for two contactors
plugged in on the front in the recesses on the left next to
the connection block To be ordered separately:
11 Cover, sealable 19 Mechanical interlock

1) For contactors
3RT201. contactors with one NC contact in the basic unit
are required for the electrical interlock. An additional NO contact For contactors and coupling contactors
is required for momentary-contact operation.

Accessories and spare parts, see pages 3/69 to 3/119.

Siemens IC 10 · 2023 3/11


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
General data
3RT105 and 3RT145 contactors · Size S6 with mountable accessories

15

15

17
3

16

13
12

18
11

15
8
9
10
16
14

1
Accessories 33 to 77 and
12 to 17 can be mounted onto
12
7 2
contactors 11 and 2 respectively.

7
7
3

IC01_00651a
6
5

1 3RT105 and 3RT145 air-break contactors, size S6


(version without withdrawable coil)
2 3RT105.-.P and 3RT145.-.P air-break contactors with solid-state operating
mechanism and remaining lifetime indicator, size S6
(version with withdrawable coil and laterally mountable add-on module)

Can be mounted onto the front of contactors 1 and 2 Can be plugged onto the top of contactor operating
3 3RT1926: Auxiliary switch, electronically delayed (ON-delay or OFF-delay mechanisms 88 and 99
or star-delta (wye-delta) starting) 11 3RT1956-1C: Surge suppressor (RC element)
4 3RH192: 4-pole auxiliary switch
Can be mounted onto the top or bottom on busbars or box
5 3RH192: 1-pole auxiliary switch (max. four can be snapped on) terminals of contactors 11 and 2
6 3RT1926-4MA10: Cover, sealable 12 3RT1956-4G: Box terminal block
Can be mounted onto the side of contactors 1 and 2 13 3TX7500-0A: Auxiliary conductor terminal, 1-pole
7 3RH192: 2-pole auxiliary switch 14 3TX6526-3B: Terminal cover (can be screwed on), covers one
busbar connection
Can be inserted in top of contactors
15 3RT1956-4EA1: Terminal cover for busbar connection and on box
8 3RT1955-5A.3.: Withdrawable coil, standard operating mechanism terminal
9 3RT1955-5N.3.: Withdrawable coil, solid-state operating mechanism 16 3RT1956-4EA3: Terminal cover for busbar connection
10 3RT1955-5P.3.: Withdrawable coil, solid-state operating mechanism and 17 3RT1956-4EA2: Terminal cover on box terminal
remaining lifetime indicator
18 3RT1956-4EA4: Terminal cover for busbar connection,
covers 15 , 16 to 18
18 can be mounted

Accessories and spare parts, see pages 3/69 to 3/119.

3/12 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
General data
3RT106 and 3RT146 contactors · Size S10 with mountable accessories

14

16

3
12

11

14

8
9
10
15
13

Accessories 33 to 7 and 2
12 to 16
17 can be mounted onto 7
contactors 1 and 2 respectively.
7
7
3

IC01_00652b
5 6

1 3RT106 and 3RT146 air-break contactors, size S10 Can be inserted in the top of contactors
(version without withdrawable coil) 8 3RT1965-5A.3.: Withdrawable coil, standard operating mech.
2 3RT106.-.P and 3RT146.-.P air-break contactors with solid-state operating 9 3RT1965-5N.3.: Withdrawable coil, solid-state operating mech.
mechanism and remaining lifetime indicator, size S10 10 3RT1965-5P.3.: Withdrawable coil, solid-state operating mech.
(version with withdrawable coil and laterally mountable add-on module) and remaining lifetime indicator
Can be mounted onto the front of contactors 11 and 2 Can be plugged onto the top of contactor operating
mechanisms 88 and 99
3 3RT1926: Auxiliary switch, electronically delayed (ON-delay or OFF-delay
or star-delta (wye-delta) starting) 11 3RT1956-1C: Surge suppressor (RC element)
4 3RH192: 4-pole auxiliary switch Can be mounted at the top or bottom on busbars or box
5 3RH192: 1-pole auxiliary switch (max. four can be snapped on) terminals of contactors 11 and 22
6 3RT1926-4MA10: Cover, sealable 12 3RT1966-4G: Box terminal block
Can be mounted onto the side of contactors 1 and 2 13 3TX6546-3B: Terminal cover (can be screwed on), covers one
busbar connection
7 3RH192: 2-pole auxiliary switch
14 3RT1966-4EA1: Terminal cover for busbar connection and on box
terminal
15 3RT1966-4EA3: Terminal cover for busbar connection
16 3RT1966-4EA2: Terminal cover on box terminal

Accessories and spare parts, see pages 3/69 to 3/119.

Siemens IC 10 · 2023 3/13


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
General data
3RT126 vacuum contactors · Size S10 with mountable accessories

9 11
3

10
7

3
4

1
IC01_00653b

1 3RT126 vacuum contactor, size S10


(version without withdrawable coil)
Can be mounted onto side of contactor Can be mounted onto the top or bottom on busbars
2 3RH192: 2-pole auxiliary switch or box terminals
7 3RT1966-4G: Box terminal block
Can be inserted in top of contactor
3 3RT1966-5A.3.: Withdrawable coil, standard operating mechanism 8 3TX6546-3B: Terminal cover (can be screwed on), covers one
busbar connection
4 3RT1966-5N.3.: Withdrawable coil, solid-state operating mechanism
9 3RT1966-4EA1: Terminal cover for busbar connection and on box
Can be plugged onto top of contactor operating mechanisms terminal
5 3RT1956-1C: Surge suppressor (RC element) 10 3RT1966-4EA3: Terminal cover for busbar connection
Can be mounted at bottom on busbars 11 3RT1966-4EA2: Terminal cover on box terminal
6 3RT1966-1PV.: Main current path surge suppression module

Accessories and spare parts, see pages 3/69 to 3/119 and


3/133 to 3/137.

3/14 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
General data
3RT107 and 3RT147 contactors · Size S12 with mountable accessories

14

16

3
12
11

14

8
9
10

15

13

Accessories 33 to 7 and 2
12 to 16
12 17 can be mounted onto
7
contactors 1 and 2 respectively.

7
7
3

IC01_00654b
5 6

1 3RT107 and 3RT147 air-break contactors, size S12 Can be inserted in top of contactors
(version without withdrawable coil) 8 3RT1975-5A.3.: Withdrawable coil, standard operating mech.
2 3RT107.-.P and 3RT147.-.P air-break contactors with solid-state operating 9 3RT1975-5N.3.: Withdrawable coil, solid-state operating mech.
mechanism and remaining lifetime indicator, size S12 10 3RT1975-5P.3.: Withdrawable coil, solid-state operating mech.
(version with withdrawable coil and laterally mountable add-on module) and remaining lifetime indicator
Can be mounted onto the front of contactors 1 and 2 Can be plugged onto top of contactor operating
mechanisms 88 and 99
3 3RT1926: Auxiliary switch, electronically delayed (ON-delay or OFF-delay
or star-delta (wye-delta) starting) 11 3RT1956-1C: Surge suppressor (RC element)
4 3RH192: 4-pole auxiliary switch Can be mounted at the top or bottom on busbars or box
5 3RH192: 1-pole auxiliary switch (max. four can be snapped on) terminals of contactors 11 and 2
6 3RT1926-4MA10: Cover, sealable 12 3RT1966-4G: Box terminal block
13 3TX6546-3B: Terminal cover (can be screwed on), covers one
Can be mounted onto the side of contactors 1 and 2
busbar connection
7 3RH192: 2-pole auxiliary switch
14 3RT1966-4EA1: Terminal cover for busbar connection and on box
terminal
15 3RT1966-4EA3: Terminal cover for busbar connection
16 3RT1966-4EA2: Terminal cover on box terminal

Accessories and spare parts, see pages 3/69 to 3/119.

Siemens IC 10 · 2023 3/15


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
General data
3RT127 vacuum contactors · Size S12 with mountable accessories

9 11
3

10
7

3
4
8

1
IC01_00573b

1 3RT127 vacuum contactor, size S12


(version without withdrawable coil)
Can be mounted onto the side of contactor Can be mounted at the top or bottom on busbars or box terminals
2 3RH192: 2-pole auxiliary switch 7 3RT1966-4G: Box terminal block
Can be inserted in top of contactors 8 3TX6546-3B: Terminal cover (can be screwed on), covers one
busbar connection
3 3RT1975-5A.3.: Withdrawable coil, standard operating mechanism
4 3RT1975-5N.3.: Withdrawable coil, solid-state operating mechanism 9 3RT1966-4EA1: Terminal cover for busbar connection and on box
terminal
Can be plugged onto the top of contactor operating mechanisms 10 3RT1966-4EA3: Terminal cover for busbar connection
5 3RT1956-1C: Surge suppressor (RC element) 11 3RT1966-4EA2: Terminal cover on box terminal
Can be mounted at bottom on busbars
6 3RT1966-1PV.: Main current path surge suppression module

Accessories and spare parts, see pages 3/69 to 3/119 and


3/133 to 3/137.

3/16 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
General data
3TF68 and 3TF69 vacuum contactors · Size S14 with mountable accessories

3
4

IC01_00721a
3

1 3TF68 and 3TF69 vacuum contactors, size 14

Can be inserted or mounted on the front of the contactor (with the Can be mounted on the front from above or below on busbars
cover removed) 4 Box terminal (1 set = 3 units)
2 Solenoid coils for AC operation, with switch-on electronics for contactor 3TF68: 3TX7570-1E
3TF6844-.C: 3TY7683-0C.7 3TF69: 3TX7690-1F
3TF6944-.C: 3TY7693-0C.7 5 Terminal cover for busbar connection (1 set = 2 units),
3 Solenoid coils for AC control supply voltage subject to attached to the right and left busbar connection in each case
strong interference 3TF68: 3TX7686-0A
3TF6833-.Q: 3TY7683-0Q.7 3TF69: 3TX7696-0A
3TF6933-.Q: 3TY7693-0Q.7 Can be mounted on the front of 3TF68 contactors from below on
Solenoid coils for DC operation busbars
3TF6833-.D: 3TY7683-0D.4 6 Terminal cover for busbar connection
(on outgoing side in combination with overload relay)
3TF68: 3TX7686-0B
Can be snapped onto the left-hand side of the auxiliary switches
7 Surge suppressor (only with DC operation)
3TF6.33-.D: 3TX7572-3.

Accessories and spare parts, see pages 3/133 to 3/137.

Siemens IC 10 · 2023 3/17


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

■ Overview
Version Size Ratings of three- Connection methods Type Page
phase motors at Screw Spring-
50 Hz and 400 V terminals loaded
terminals
kW
Power contactors for switching motors
AC operation
3

Basic unit S00 3 ... 7.5 ✓ ✓ 3RT201.-.A.0. 3/47


• With permanently mounted auxiliary switch ✓ ✓ 3RT201.-.AP04-3MA0 3/47
• With permanently mounted auxiliary switch and varistor ✓ ✓ 3RT201.-.CP04-3MA0 3/47
plugged into the front
Basic unit S0 4 ... 18.5 ✓ ✓ 3RT202.-.A.00 3/48
• With removable auxiliary switch ✓ ✓ 3RT202.-.A.04 3/49
• With permanently mounted auxiliary switch and varistor ✓ ✓ 3RT202.-.CL24-3MA0 3/49
plugged in
Basic unit S2 18.5 ... 37 ✓ ✓ 3RT203.-.A.00 3/50
• With removable auxiliary switch ✓ -- 3RT203.-1A.04 3/50
• With permanently mounted auxiliary switch and integrated ✓ ✓ 3RT203.-.CL24-3MA0 3/50
coil circuit
Basic unit S3 37 ... 55 ✓ ✓ 3RT20.-.A.00 3/51
• With removable auxiliary switch ✓ -- 3RT204.-1A.04 3/51
• With permanently mounted auxiliary switch and integrated ✓ -- 3RT204.-1CL24-3MA0 3/51
coil circuit
DC operation
Basic unit S00 3 ... 7.5 ✓ ✓ 3RT201.-.B.4. 3/52
• With integrated coil circuit ✓ ✓ 3RT201.-..B4. 3/52
• With permanently mounted auxiliary switch ✓ ✓ 3RT201.-.BB44-3MA0 3/53
• With permanently mounted auxiliary switch and integrated ✓ ✓ 3RT201.-.FB44-3MA0 3/53
coil circuit
• With voltage tap-off ✓ ✓ 3RT201.-.BB4.-0CC0 3/53
Basic unit S0 4 ... 18.5 ✓ ✓ 3RT202.-.B.40 3/56
• With coil circuit plugged into front ✓ ✓ 3RT202.-..B40 3/56
• With removable auxiliary switch ✓ ✓ 3RT202.-.BB44 3/56
• With permanently mounted auxiliary switch and integrated ✓ ✓ 3RT202.-..B44-3MA0 3/57
coil circuit
• With voltage tap-off ✓ ✓ 3RT202.-.BB40-0CC0 3/57
DC operation for direct control by PLC (coupling contactors)
Basic unit S00 3 ... 5.5 ✓ ✓ 3RT201.-..B4. 3/54
Basic unit with integrated coil circuit S00 3 ... 5.5 ✓ ✓ 3RT201.-..B4. 3/54, 3/55
S0 4 ... 15 ✓ ✓ 3RT202.-.KB40 3/58
S2 18.5 ... 37 ✓ ✓ 3RT203.-.KB40 3/59
S3 37 and 45 ✓ ✓ 3RT204.-.KB40 3/59
AC/DC operation (50/60 Hz AC or DC)
Basic unit with integrated coil circuit S0 5.5 ... 18.5 ✓ ✓ 3RT202.-.N.30 3/60
Basic unit with integrated coil circuit S2 18.5 ... 37 ✓ ✓ 3RT203.-.N.30 3/61
• With removable auxiliary switch ✓ -- 3RT203.-1N.34 3/61
• With permanently mounted auxiliary switch ✓ ✓ 3RT203.-.NB34-3MA0 3/61
• With voltage tap-off ✓ ✓ 3RT203.-.NB30-0CC0 3/61
• With fail-safe 24 V DC control signal input for safety-related ✓ ✓ 3RT203.-.S.30 3/62
applications up to SIL 3
Basic unit with integrated coil circuit S3 37 ... 55 ✓ ✓ 3RT204.-.N.30 3/63
• With removable auxiliary switch ✓ -- 3RT204.-1N.34 3/63
• With permanently mounted auxiliary switch ✓ ✓ 3RT204.-.NB34-3MA0 3/63
• With voltage tap-off ✓ ✓ 3RT204.-.NB30-0CC0 3/63
• With fail-safe 24 V DC control signal input for safety-related ✓ ✓ 3RT204.-.S.30 3/62
applications up to SIL 3
Basic unit with integrated coil circuit
• Standard operating mechanism for AC and DC operation S6 ... S12 55 ... 250 ✓1) ✓ 3RT10..-.A.36 3/64
• Solid-state operating mechanism with the option of control
via a separate 24 V DC control signal input
- Fail-safe control signal input S6 ... S12 55 ... 250 ✓1) -- 3RT10..-.S.36 3/65
for safety-related applications up to SIL 3
- Standard control signal input ✓1) ✓ 3RT10..-.N.36 3/66
- Standard control signal input, with remaining lifetime ✓1) -- 3RT10..-.P.35 3/66
indicator (RLT)
1)
-- Version not possible Connection method:
✓ Version possible - Main circuit: Busbar connection (optionally with box terminals),
- Auxiliary/control circuit: Screw terminals or spring-loaded terminals.

3/18 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

3
Contactors with screw terminals: 3RT20 (sizes S00 to S3) and 3RT10 (sizes S6 to S12)
Our power range of contactors for switching IE2 motors and Standards
highly efficient IE3 and IE4 motors:
IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1 (auxiliary switches)
• Contactors,
see pages 3/47 to 3/66: Contactors with increased tamper protection
- Size S00: 3RT201 up to 7.5 kW Increased tamper protection is ensured either by using our
- Size S0: 3RT202 up to 18.5 kW contactor versions with factory-installed, permanently mounted
- Size S2: 3RT203 up to 37 kW auxiliary switches protected against mechanical external
- Size S3: 3RT204 up to 55 kW actuation (e.g. 3RT20...-.....-3MA0 or 3RT10...-.....-3PA0
- Sizes S6 to S12: 3RT10 up to 250 kW contactors), or by using the 3RT2916-4MA10 or
• Vacuum contactors, 3RT1926-4MA10 sealable cover as an accessory
see page 3/120 onwards: (see page 3/112).
- Sizes S10 and S12: 3RT12 up to 250 kW
- Size 14: 3TF6 up to 450 kW

Siemens IC 10 · 2023 3/19


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW
Operating times

Coil voltage A1/A2 OFF ON OFF

Switching state of 1/2 open CD closed OD AT open


main contacts
Switching state of 13/14 open CD closed OD open

IC01_00747a
3

auxiliary NO contacts
Switching state of 21/22 closed OD open CD closed
auxiliary NC contacts
t (ms)
20 ms
CD = closing delay
OD = opening delay
AT = arcing time
Operation Closing delay Opening delay Total break time =
Opening delay +
Arcing time 10 … 15 ms
AC 20 ... 95 ms 40 ... 60 ms 50 ... 75 ms
DC 20 ... 95 ms 40 ... 60 ms 50 ... 75 ms

Operating times using the example of contactor 3RT1054-1AB36


Protection of the device connections from short circuit, Protection of contactors with digital input from short circuit and
overload and overvoltage overload
Appropriate steps must always be taken to protect device For the PLC input types according to IEC 60947-4-1 these inputs
connections from overload and short circuit. There are different have a typical rated current of 20 mA. These inputs can be
constraints depending on the type of connection: protected accordingly.
Protection of main terminals from short circuit and overload • Contactors with PLC and F-PLC inputs:
- For 3RT10..-.P marked with IN+/IN-
For information about protection of a single contactor, - For 3RT10..-.S, -.N and 3RT20..-.S marked with +/-
see the technical product data sheet.
• Supply voltage connections A1 - A2:
For more information on complete units such as contactors - For 3RT10..-.N, -.P and 3RT20..-.S, protection should be
with overload relays or contactors with motor starter protectors provided on the basis of the load characteristics.
as the motor feeder, see Configuration Manual for load feeders. For information about power consumption, see the technical
product data sheet.
Protection of auxiliary connections from short circuit and - For 3RT10..-.S, protection is already integrated.
overload
Protection of other connections from short circuit and overload
For information about protection of auxiliary contacts,
see the technical product data sheet. The contactor version 3RT10..-.P with remaining lifetime
indicator (RLT) has additional connections H1 - H2 and R1 - R2.
Protection of control supply voltage or supply voltage
connections from short circuit and overload If A1 - A2 is already protected, further protection of H1 - H2 is not
required.
First of all, the relevant standards and regulations for configuring
control panels and the parts and components installed in them For information about protection of R1 - R2, see the technical
must be taken into account, for example when dimensioning product data sheet.
the cables.
Overvoltage protection at the control supply voltage connection
One possible protection for these circuits could be the selection
of a suitable power supply, i.e. one with a current-limiting 3RT20 contactors supplied without a coil circuit can be
function. In the selection of the source and the connecting cable, retrofitted with RC elements, varistors, diodes or diode
the load characteristics of the contactor must be considered assemblies (combination of diode and Zener diode for short
(short-time inrush current peaks for solid-state contactor break times) for damping switching overvoltages in the coil and
operating mechanisms, closing, closed). can be ordered separately as accessories, see page 3/97
onwards.
If there are further switching elements in the circuits, such as the
auxiliary contact system of an overload relay that operates the The 3RT10 contactors are already equipped with coil damping
contactor, the short-circuit protection necessary for this must (varistor).
also be considered. Note:
For further recommendations, e.g. the use of miniature circuit The break times of the contactor, the opening delay times of the
breakers or circuit breakers for equipment in control circuits, NO contacts and the closing delay times of the NC contacts
see Control panel tip – Fast, reliable selection and dimensioning increase with damping.
of an appropriate power supply unit.
For more detailed information about how damping affects the
time response, see Equipment Manual.

3/20 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW
Connection methods Plant and application monitoring
Main circuit For monitoring and measuring in the application, 3RR2 moni-
• 3RT201 and 3RT202 contactors: toring relays can be mounted on the 3RT20 contactors (see
Screw terminals or spring-loaded terminals; page 10/47).
spring-loaded terminals with convenient plug-in design for Contactors with voltage tap
device connectors
• 3RT203 and 3RT204 contactors: The 3RT20 contactors with voltage tap-off are special versions
Screw terminals with box terminal; for mounting the SIRIUS 3RA27 function modules for connection
to the control system via IO-Link or AS-Interface (see page 3/73

3
direct connection to the connecting bar is possible with cable
lugs for 3RT204 when the box terminal is removed. onwards).
• 3RT10 contactors: Without a function module, these contactors can be used like the
Screw terminals with connecting bars that the cables can be standard versions.
connected to using either cable lugs or flexible or rigid For more information on IO-Link and AS-Interface, see
busbars. Alternatively, box terminals are available as "Industrial communication", page 2/1 onwards.
accessories.
Operating mechanism types
Auxiliary and control circuits
3RT20 contactors
The 3RT contactors are available with screw terminals or spring-
loaded terminals. The standard versions are available with AC or DC operating
mechanisms or as versions with a wide-range solid-state
Electromagnetic compatibility operating mechanism and a universal actuating voltage
The contactors fulfill the requirements for environment category A. (AC or DC operation possible).
Note: Versions with solid-state operating mechanisms for AC or DC
operation with a fail-safe PLC input are also available for the
When the contactors are used in an environment with 3RT203 and 3RT204 contactors.
frequency converters, the configuration notes must be
observed, see Equipment Manual. Control takes place via the control supply voltage connection
A1 - A2 with varying operating ranges (see the technical product
Contact reliability of the auxiliary contacts data sheet for further details).
If voltages  110 V and currents  100 mA are to be switched, DC coupling contactors with reduced power consumption are
the auxiliary contacts of the 3RT contactors or 3RH contactor also ideally suited for connection to the controller.
relays should be used as they guarantee a high level of contact
reliability. 3RT10 contactors

These auxiliary contacts are particularly suitable for solid-state The operating mechanisms are powered via a supply voltage
circuits with currents  1 mA at a voltage  17 V. with an operating range from 0.8 to 1.1 x Us, optionally also
controlled depending on the chosen mode of operation. Various
Motor protection rated voltage ranges are available for AC/DC control.
3RT20 contactors The following control and/or operating mechanism versions can
be selected for contactors 3RT105 to 3RT107:
For protection against overload, 3RU2 thermal overload relays
(see page 7/89 onwards) or 3RB3 electronic overload relays • 3RT10..-.A contactors:
(see page 7/102 onwards) can be mounted on the 3RT20 Standard operating mechanism for AC and DC operation
contactors. (reduced power consumption when closing and in the closed
state)
3RT10 contactors
• Solid-state operating mechanisms:
For protection against overload, 3RB2 electronic overload relays Overvoltage damping of the operating mechanism coil is
(see page 7/114 onwards) can be mounted on the 3RT10 already integrated in the electronics for contactors with
contactors. solid-state operating mechanisms.
The following versions are available:
- 3RT10..-.N contactors:
With two operating modes: Direct control or via PLC input
(24 V DC)
- 3RT10..-.P contactors:
Control via PLC input (24 V DC) only, but with additional
remaining lifetime indicator (RLT)
- 3RT10..-.S contactors:
Control via fail-safe PLC input (24 V DC) only, for
simplification of safety applications (without mode of
operation selection)

Siemens IC 10 · 2023 3/21


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW
Replacing solenoid coils, operating mechanisms or spare Fitting auxiliary contacts and mounting additional auxiliary
contacts switches
3RT20 contactors Features in the delivery state
Coil replacement is possible for contactors 3RT202 to 3RT204. • 3RT20 contactors:
- 3RT201 contactors:
NOTICE: An auxiliary contact is integrated in the basic unit.
Removal or changing of the operating mechanism or spare - Contactors 3RT202 to 3RT204:
contacts is not permitted for 3RT20..-.S contactors with fail-safe The basic units contain two integrated auxiliary contacts
control. (1 NO + 1 NC).
3

3RT10 contactors • 3RT10 contactors:


These contactors are supplied with two laterally mounted
The operating mechanisms for 3RT10..-.A/-.N/-.P contactors are auxiliary switches. The fitting of auxiliary switches is possible
removable and can be replaced simply by unlocking and pulling on the front and on the side.
them out.
Expansion possibilities
NOTICE:
Removal or changing of the operating mechanism is not All basic units (with the exception of coupling contactors in sizes
permitted for 3RT10..-.S contactors with fail-safe control. S00 and S0) can be expanded using auxiliary switches.
The permitted configuration must be taken into account.
For detailed information about the fitting of auxiliary switches for
3RT20 contactors, see pages 3/81 to 3/86.

3/22 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW
Connection of contactors to fail-safe control modules
While contactors with smaller power ratings can be connected Due to their fail-safe control input, special contactors provide
directly to the outputs of fail-safe controllers, implementing a much simpler way of doing this:
safety-related applications with standard contactors with higher • 3RT20..-.S contactors in sizes S2 and S3
power is much more complicated and elaborate because of the • 3RT10..-.S contactors in sizes S6 to S12
necessary coupling links.
For more information, see
• Safety technology, page 11/1 onwards
• Guide of use for contactors in safety applications

3
Example for SIL 2 and SIL 3/PL e application – previously:

L/+ 3RT contactors in sizes S2 to S12


with standard or solid-state operating mechanism
with PLC-IN (3RT105 contactor is shown)
3RT2 contactor or • Safety-related tripping only possible via coupling
3RH2 contactor relay
links and F-DQ
• Standard operating mechanism:
3RT2 contactor operational switching via coupling links and
F-DQ
Feedback • Solid-state operating mechanism:
operational switching with PLC-IN and DQ
EMERGENCY SIMATIC S7-1500 DQ
STOP F-DQ 3RT1
contactor
A1
PLC-IN
A2

3RT1 contactor

A1
PLC-IN
A2
IC01_00704

N/-

Application with safety-related disconnection with standard contactors using the example of a 3RT105 contactor
Example for SIL 3/PL e (left-hand side) or SIL 2/PL c (right-hand side) application – new:

L/+ 3RT contactors in sizes S2 to S12


with solid-state operating mechanism with fail-safe
control input F-PLC-IN (3RT1055-6SP36 contactor
is shown)
Feedback • Safety-related tripping and operational switching
via F-PLC-IN and F-DQ
• SIL 2/PL c possible with only one contactor
SIL 3/PL e with
two contactors

EMERGENCY SIMATIC S7-1500


STOP 3RT1 contactor
F-DQ
A1
F-PLC-IN SIL 2/PL c with
one contactor L/+
A2
Feedback

3RT1 contactor 3RT1 contactor


A1 A1
F-PLC-IN F-PLC-IN
A2 A2
IC01_00705

N/- N/-

Application with safety-related disconnection with contactors with fail-safe control using the example of a 3RT105 contactor

Siemens IC 10 · 2023 3/23


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW
Contactors for special applications
• SIRIUS 3RT.4 contactors for low or non-inductive loads
(AC-1), 3-pole, see page 4/7 onwards
• SIRIUS 3RT20 and 3RT10 contactors with an extended
application range, 3-pole (for railway applications), see
page 4/54 onwards

Article number scheme


3

Product versions Article number


SIRIUS power contactors 3RT2 @ @ @ – @ @ @ @ @ – @ @ @ @
Device type e.g. 0 = 3-pole motor contactor @
Size of the contactor e.g. 4 = S3 @
Rating dependent on size e.g. 5 = 37 kW for S3 @
Type of electrical connection e.g. 1 = screw terminals (main and auxiliary circuits) @
Operating range/solenoid coil circuit e.g. A = AC standard/without coil circuit @
Rated control supply voltage e.g. P0 = 230 V AC, 50 Hz @@
Auxiliary switches e.g. 0 = for S3: 1 NO + 1 NC integrated @
Special version @@@@
Example 3RT2 0 4 5 – 1 A P 0 0
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

3/24 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

■ Technical specifications
More information
Technical specifications, see System Manual for modular system, see
https://support.industry.siemens.com/cs/ww/en/ps/16134/td https://support.industry.siemens.com/cs/ww/en/view/60311318
FAQs, see Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/ps/16134/faq https://support.industry.siemens.com/cs/ww/en/view/60306557
Application Manual - Switching devices with IE3 and IE4 motors, see
https://support.industry.siemens.com/cs/ww/en/view/94770820

3
Configuration Manual for load feeders, see
https://support.industry.siemens.com/cs/ww/en/view/39714188
Configuration Manual for UL, see
https://support.industry.siemens.com/cs/ww/en/view/53433538
Guide of use for contactors in safety applications, see
https://support.industry.siemens.com/cs/ww/en/view/109807687

Type Contactors
3RT2 3RT1
Size S00 to S2 S3 S6 to S12
Rated data of the auxiliary contacts
According to IEC 60947-5-1
Data apply to integrated auxiliary contacts and conventional contacts
in the auxiliary switches
Rated insulation voltage Ui (pollution degree 3) V 690 1 000 --
(3RT20..-0CC0: 690)
• For laterally mountable auxiliary switches V 690 690 500
• For front auxiliary switches V 690 690 690
Conventional thermal current Ith = A 10
rated operational current Ie/AC-12
AC load
Rated operational current Ie/AC-15/AC-14
• At rated operational voltage Ue Up to 230 V A 101) 6 6
400 V A 3 3
500 V A 2 2
690 V A 1 12)
DC load
Rated operational current Ie/DC-12
• At rated operational voltage Ue 24 V A 10 10
60 V A 6 6
110 V A 3 3
125 V A 2 2
220 V A 1 1
440 V A 0.3 0.3
600 V A 0.15 0.152)
Rated operational current Ie/DC-13
• At rated operational voltage Ue 24 V A 101) 103)
60 V A 2 2
110 V A 1 1
125 V A 0.9 0.9
220 V A 0.3 0.3
440 V A 0.14 0.14
600 V A 0.1 0.152)
Contact reliability at 17 V, 1 mA Frequency of contact faults < 10-8 i.e. < 1 fault per 100 million operating cycles
According to IEC 60947-5-4
1)
3RH22, 3RH29, 3RT2...-....4, 3RT2...-....6: Ie = 6 A at AC-15/AC-14 and
DC-13.
2)
With laterally mountable auxiliary switches, only the currents for rated
operational voltages up to 500 V apply.
3) For laterally mountable auxiliary switches, DC-13/at 24 V: max. 6 A.

Siemens IC 10 · 2023 3/25


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Type 3RT contactors


Size S00 to S12
Electrical endurance of auxiliary contacts
It is assumed that the operating mechanisms are switched arbitrarily Sizes S00 to S3
and not synchronously with the phase angle of the supply system
switching operating mechanism. 30 NSB0_02061d
Basic unit
The electrical contact endurance is mainly dependent on the

Million operating cycles (106)


breaking current. 10
3

5 Basic unit with


4 attachable
3 AC-15/AC-14
2 contact block
DC-13 DC-13 Basic unit with
1 220 V 110 V attachable
0,5 contact block

DC-13
24 V
0,1
1)
0,05

0,01
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 6 7 10 a (A)
e -DC-13 e -DC-13 e -DC-13 e -AC-15
220 V 110 V 24 V < 230 V
Diagram legend:
a = Breaking current
e = Rated operational current

The characteristic curves apply to:


• integrated auxiliary contacts on 3RT2.
• 3RH2911, 3RH2921 auxiliary switches1)
Sizes S6 to S12
30
NSB0_00472d
Basic unit
Million operating cycles (106)

10
5 Basic unit
4 with attach.
3 contact block
2
DC-13
1 220 V DC-13 AC-15/AC-14
0,5 110 V

DC-13
24 V
0,1
0,05

2)

0,01
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 5 6 7 10 (A)
a

e -DC-13 e -DC-13 e -AC-15 e -DC-13


220 V 110 V < 230 V 24 V
Diagram legend:
a = Breaking current
e = Rated operational current

The characteristic curves apply to:


• Integrated auxiliary contacts on 3RT10
• 3RH1921 auxiliary switches3)
1) 3RH22, 3RH29, 3RT2...-....4, 3RT2...-....6: Ie = 6 A at AC-15/AC-14 and
DC-13, 3RT2.4: Ie = 6 A at AC-15/AC-14.
2)
For laterally mountable auxiliary switches, DC-13/at 24 V: max. 6 A.
3)
With laterally mountable auxiliary switches, the currents for rated
operational voltages up to 500 V apply.

3/26 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Type 3RT2 contactors


Size S00 and S0
Contact endurance of the main contacts
The characteristic curves show the contact Size S00
endurance of the contactors when switching
low inductive or non-inductive AC loads Operating cycles at
(AC-1) and motor-driven loads (AC-3 and

230 V

500 V

690 V

400 V
AC-3e) depending on the breaking current
and rated operational voltage. It is assumed Contactor 3RT2015, 3RT2016 3RT2017, 3RT2018

3
that the operating mechanisms are switched 7 type (3 kW, 4 kW) (5,5 kW, 7,5 kW)
arbitrarily and not synchronously with the 7 10
10 8 6 8
NSB0_02059a
phase angle of the supply system switching 6
8 4 6
operating mechanism. 6 4 4
The rated operational current Ie complies with 4 2
utilization category AC-4 (breaking 6 times 2
the rated operational current) and is intended 6 2
2 6 10
for a contact endurance of approximately 10 8 10
6
6 8
200 000 operating cycles. 10 6 8
8 6 4 6
If a shorter contact endurance is sufficient,
the rated operational current Ie/AC-4 can be 6 4 4
increased. 4 2
If the contacts are used for mixed operation, 2 2
2 5
i.e. normal switching (breaking the rated 5 10
operational current according to utilization 10 8 105
5
category AC-3 and AC-3e) in combination 10 8 6 8
with intermittent inching (breaking several 8 6 4 6
times the rated operational current according 6 4 4
to utilization category AC-4), the contact 4 2
endurance can be calculated approximately 2
from the following equation: 4
2
2 10
4
A 10 8 10
4
X = ---------------------------------------------------------- 2 3 4 5 6 8 10 15 20 30 40 50 60 80 100
1 + ----------  ---- – 1
C A
100  B  Breaking current a (A)

Characters in the equation: Size S0


X Contact endurance for mixed operation
Operating cycles at
in operating cycles
230 V

500 V

690 V

400 V

A Contact endurance for normal operation


(Ia = Ie) in operating cycles Cont. 3RT2023 3RT2024 3RT2025 3RT2026
B Contact endurance for inching 7 type (4 kW) (5,5 kW) (7,5 kW) (11 kW)
(Ia = multiple of Ie) in operating cycles 10
107 8 6 8
NSB0_02060a
C Inching operations as a percentage of 6
8 4 6
total switching operations 6 4 4
4 2
2 2 3RT2027, 3RT2028
6
2 6 10 (15 kW, 18,5 kW)
10 8 106
106 8 6 8
8 6 4 6
6 4 4
4 2
2 2
2 5
5 10
10 8 105
105 8 6 8
8 6 6
4
6 4 4
4 2
2 2
2 4
4 10
10 8 104
3 4 5 6 8 10 15 20 30 40 50 60 80 100 150 200
Breaking current a (A)

Siemens IC 10 · 2023 3/27


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Type 3RT contactors


Size S2 to S12
Contact endurance of main contacts
(continued)
Size S2
Operating cycles at

230 V

500 V

690 V

400 V
Contactor 3RT2035 3RT2036 3RT2037 3RT2038
3

7 type (18,5 kW) (22 kW) (30 kW) (37 kW)


7 10
10 8 6 8 IC01_00456
8 6 4 6
6 4 4
4 2
2 6 2
2 6 10
6 10 8 106
10 8 6 8
8 6 4 6
6 4 4
4 2
2 5 2
2 5 10 5
5 10 8 10
10 8 6 8
8 6 4 6
6 4 4
4 2
2 2
2 4
4 10 4
10 8 10
10 20 30 40 50 60 80 100 150 200 300 400500
Breaking current a (A)

Size S3
Operating cycles at
230 V

500 V

690 V

400 V

Contactor 3RT2045 3RT2046 3RT2047


7 type (37 kW) (45 kW) (55 kW)
7 10
10 8 6 8 IC01_00521a
8 6 4 6
6 4 4
4 2
2 6 2
2 6 10
6 10 8 106
10 8 6 8
8 6 4 6
6 4 4
4 2
2 5 2
2 5 10 5
5 10 8 10
10 8 6 8
8 6 4 6
6 4 4
4 2
2 2
2 4
4 10 4
10 8 10
10 20 30 40 50 60 80 100 200 300 400 500 600
Breaking current a (A)

Sizes S6 to S12
Operating cycles at
230 V
500 V

690 V

400 V

Contactor type
3RT1054 3RT1055 3RT1056 3RT1064 3RT1065 3RT1066 3RT1075 3RT1076
7 (55 kW) (75 kW) (90 kW) (110 kW) (132 kW) (160 kW) (200 kW) (250 kW)
7 10
10 8 6 8 NSB0_01141a
8 6 4 6
6 4 4
4 2
2 6 2
2 6 6 10
10
6 10 8
10 8 8 6
8 6 6 4
6 4 4
4 2
2 5 2
2 5 10 5
5 10 8 10
10 8 6 8
8 6 4 6
6 4 4
4 2
2 4 2
2 4 10 4
10 8 10
10 20 30 40 50 60 80 100 150 200 300 400 600 800 1 000 2 0003 000
Breaking current a (A)

3/28 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT2015, 3RT2016 3RT2017, 3RT2018
Size S00
General data
Dimensions (W x H x D)
• Basic unit
- Screw terminals mm 45 x 58 x 73

H
- Spring-loaded terminals mm 45 x 70 x 73

3
D
• Basic unit with mounted auxiliary switch W
- Screw terminals mm 45 x 58 x 117
- Spring-loaded terminals mm 45 x 70 x 121
• Basic unit with mounted function module or
solid-state time-delayed auxiliary switch
- Screw terminals mm 45 x 58 x 147
- Spring-loaded terminals mm 45 x 70 x 147
Permissible mounting position
The contactors are designed for operation on

NSB0_00478c
360° 22,5° 22,5°
a vertical mounting surface.

Upright mounting position

NSB0_00477a

Special version required


Mechanical endurance
• Basic unit Operat- 30 million
ing
cycles
- With mounted auxiliary switch Operat- 10 million
ing
cycles
- With solid-state compatible auxiliary switch Operat- 5 million
ing
cycles
Electrical endurance For contact endurance of the main contacts, see page 3/27.
Rated insulation voltage Ui (pollution degree 3) V 690
Rated impulse withstand voltage Uimp
• Auxiliary circuit kV 6
• Main circuit kV 6
Protective separation between the coil and the main contacts V 400
according to IEC 60947-1, Annex N
Mirror contacts
A mirror contact is an auxiliary NC contact that cannot be closed
simultaneously with an NO main contact.
• 3RT2.1 (removable auxiliary switch) Yes, in the basic unit as well as between the basic unit and the mounted
auxiliary switch according to IEC 60947-4-1 Annex F
• 3RH2919-.NF.. solid-state compatible auxiliary switches No mirror contact for size S00
Ambient temperature
• During operation °C -25 ... +60
• During storage °C -55 ... +80

Siemens IC 10 · 2023 3/29


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT2015, 3RT2016 3RT2017, 3RT2018
Size S00
Short-circuit protection
Main circuit
• Fuse links, operational class gG:
LV HRC, type 3NA; DIAZED, type 5SB; NEOZED, type 5SE
according to IEC 60947-4-1
3

- Type of coordination "1" A 35 50


- Type of coordination "2" A 20 25
- Weld-free (test conditions according to IEC 60947-4-1) A 10
• Miniature circuit breaker (up to 230 V) with C characteristic A 10
Short-circuit current 1 kA, type of coordination "1"
Auxiliary circuit
Short-circuit test according to IEC 60947-5-1
• With fuse links, operational class gG: A 10
DIAZED, type 5SB; NEOZED, type 5SE
with short-circuit current Ik = 1 kA
• With 230 V miniature circuit breaker, C characteristic A 6
with short-circuit current Ik = 400 A
Short-circuit protection for contactors with overload relays See Configuration Manual for load feeders
Short-circuit protection for fuseless load feeders See 3RA2 load feeders, page 8/5 onwards
Control
Solenoid coil operating range
• AC operation 50 Hz 0.8 ... 1.1 x Us
60 Hz 0.85 ... 1.1 x Us
• DC operation Up to 50 °C 0.8 ... 1.1 x Us
Up to 60 °C 0.85 ... 1.1 x Us
Power consumption of the solenoid coils
(for cold coil and 1.0 x Us)
• AC operation, 50/60 Hz, standard version
- Closing VA 27/24.3 37/33
- P.f. 0.8/0.75
- Closed VA 4.2/3.3 5.7/4.4
- P.f. 0.25/0.25
• AC operation, 50 Hz, for USA/Canada
- Closing VA 26.4 36
- P.f. for closing 0.81 0.8
- Closed VA 4.4 5.9
- P.f. for closed 0.24
• AC operation, 60 Hz, for USA/Canada
- Closing VA 31.7 43
- P.f. for closing 0.81 0.8
- Closed VA 4.8 6.5
- P.f. for closed 0.25
• DC operation (closing = closed) W 4
Permissible residual current of the electronics
(with 0 signal)
• AC operation < 3 mA x (230 V/Us)1) < 4 mA x (230 V/Us)1)
• DC operation < 10 mA x (24 V/Us)1)
1) The 3RT2916-1GA00 additional load module is recommended for higher
residual currents, see page 3/114.

Coupling contactors
Type 3RT201.-.HB4. 3RT201.-.JB4. 3RT201.-.KB4. 3RT201.-.MB4.-0KT0 3RT201.-.VB4. 3RT201.-.SB4.
Size S00
Control
Solenoid coil 0.7 ... 1.25 x Us 0.85 ... 1.85 x Us
operating range
Power consumption of at Us 24 V DC W 2.8 1.6
the solenoid coils
(for cold coil)
Closing = Closed
Permissible residual current < 6 mA x (24 V/Us) On request
of the electronics (with 0 signal)
Upright mounting position On request
Overvoltage No overvoltage Integrated Integrated No overvoltage Integrated Integrated
configuration of the damping diode suppressor damping diode suppressor
solenoid coil diode diode

3/30 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT2015 3RT2016 3RT2017 3RT2018
Size S00
Rated data of the main contacts
Load rating with AC
Utilization category AC-3 and AC-3e
• Rated operational currents Ie Up to 400 V A 7 9 12 16
440 V A 7 9 11 14

3
500 V A 6 7.7 9.2 12.4
690 V A 4.9 6.7 8.9
• Rated power for slip-ring or squirrel-cage at 230 V kW 1.5 2.2 3 4
motors at 50 and 60 Hz 400 V kW 3 4 5.5 7.5
690 V kW 4 5.5 7.5
Thermal load capacity 10 s current A 56 72 96 128
Power loss per main conducting path at Ie/AC-3/ W 0.2 0.3 0.5 1
AC-3e/400 V
Utilization category AC-4 (at Ia = 6 x Ie)1)
• Maximum values
- Rated operational current Ie Up to 400 V A 6.5 8.5 11.5
- Rated power for squirrel-cage motors at Up to 400 V kW 3 4 5.5
50 Hz and 60 Hz
• The following applies to a contact endurance
of about 200 000 operating cycles:
- Rated operational currents Ie Up to 400 V A 2.6 4.1 5.5
690 V A 1.8 3.3 4.4
- Rated power for squirrel-cage motors at at 230 V kW 0.67 1.1 1.5
50 Hz and 60 Hz 400 V kW 1.15 2 2.5
690 V kW 1.15 2.5 3.5
1)
The data only apply to 3RT2516 and 3RT2517 contactors (2 NO + 2 NC)
up to a rated operational voltage of 400 V.

Contactors
Type 3RT2015 to 3RT2018
Size S00
Conductor cross-sections
Main conductors, auxiliary conductors and coil terminals Screw terminals
(1 or 2 conductors can be connected)
• Solid or stranded mm2 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1); max. 2 x 4
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1)
• AWG cables, solid or stranded AWG 2 x (20 ... 16)1); 2 x (18 ... 14)1); 2 x 12
• Terminal screw M3 (for Pozidriv size 2;  5 ... 6 mm)
• Tightening torque Nm 0.8 ... 1.2 (7 ... 10.3 lb.in)
Main conductors, auxiliary conductors and coil terminals2) Spring-loaded terminals
(1 or 2 conductors can be connected)
• Operating devices mm 3.0 x 0.5
• Solid or stranded mm2 2 x (0.5 ... 4)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 2.5)
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 12)
Auxiliary conductors for front and laterally mounted auxiliary
switches2)
(1 or 2 conductors can be connected)
• Operating devices mm 3.0 x 0.5
• Solid or stranded mm2 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
1) 2)
If two different conductor cross-sections are connected to one clamping Max. outer diameter of the conductor insulation: 3.6 mm.
point, both cross-sections must lie in one of the ranges specified. On spring-loaded terminals with conductor cross-sections  1 mm2, an
insulation stop is recommended, see page 3/115.

Siemens IC 10 · 2023 3/31


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT2023 to 3RT2025 3RT2026 to 3RT2028
Size S0
General data
Dimensions (W x H x D)
AC operation

H
• Basic unit
- Screw terminals mm 45 x 85 x 97
3

D
- Spring-loaded terminals W mm 45 x 102 x 97
• Basic unit with mounted auxiliary switch
- Screw terminals mm 45 x 85 x 141
- Spring-loaded terminals mm 45 x 102 x 145
• Basic unit with mounted function module or
solid-state time-delayed auxiliary switch
- Screw terminals mm 45 x 85 x 171
- Spring-loaded terminals mm 45 x 102 x 171
DC operation
• Basic unit
- Screw terminals mm 45 x 85 x 107
- Spring-loaded terminals mm 45 x 102 x 107
• Basic unit with mounted auxiliary switch
- Screw terminals mm 45 x 85 x 151
- Spring-loaded terminals mm 45 x 102 x 155
• Basic unit with mounted function module or
solid-state time-delayed auxiliary switch
- Screw terminals mm 45 x 85 x 181
- Spring-loaded terminals mm 45 x 102 x 181
Permissible mounting position
The contactors are designed for operation on

NSB0_00478c
360° 22,5° 22,5°
a vertical mounting surface.

Upright mounting position

NSB0_00477a

Special version required,


also applies for 3RT202.-.K.40 coupling contactors
Mechanical endurance
• Basic unit and Operat- 10 million
basic unit with mounted auxiliary switch ing
cycles
• Basic unit with solid-state compatible auxiliary switch Operat- 5 million
ing
cycles
Electrical endurance For contact endurance of the main contacts, see page 3/27.
Rated insulation voltage Ui (pollution degree 3) V 690
Rated impulse withstand voltage Uimp
• Auxiliary circuit kV 6
• Main circuit kV 6
Protective separation between the coil and the main contacts V 400
(according to IEC 60947-1, Annex N)
Mirror contacts
A mirror contact is an auxiliary NC contact that cannot be closed
simultaneously with an NO main contact.
• Integrated auxiliary switches Yes, according to IEC 60947-4-1, Annex F
• 3RT2.2. (removable auxiliary switch) Yes, according to IEC 60947-4-1, Annex F
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -55 ... +80

3/32 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT2023 to 3RT2025 3RT2026 3RT2027, 3RT2028
Size S0
Short-circuit protection
Main circuit
• Fuse links, operational class gG:
LV HRC, type 3NA; DIAZED, type 5SB; NEOZED, type 5SE
according to IEC 60947-4-1

3
- Type of coordination "1" A 63 100 125
- Type of coordination "2" A 25 35 50
- Weld-free (test conditions according to IEC 60947-4-1) A 10 16
• Miniature circuit breaker with C characteristic A 25 32 40
(short-circuit current 3 kA, type of coordination "1")
Auxiliary circuit
• Fuse links, operational class gG: A 10
DIAZED, type 5SB; NEOZED, type 5SE
(weld-free protection at Ik  1 kA)
• 230 V miniature circuit breaker, C characteristic A 10
(short-circuit current Ik < 400 A)
Short-circuit protection for contactors with overload relays See Configuration Manual for load feeders
Short-circuit protection for fuseless load feeders See 3RA2 load feeders, page 8/5 onwards

Contactors
Type 3RT2023 to 3RT2026 to 3RT202.-.NB3 3RT202.-.NF3. 3RT202.-.NP3
3RT2025 3RT2028
Size S0
Control
Type of operating mechanism AC or DC AC/DC
Solenoid coil operating range AC/DC 0.8 ... 1.1 x Us1) 0.7 ... 1.3 x Us2)
Power consumption of the solenoid coils
(for cold coil and 1.0 x Us)
• AC operation, 50 Hz, standard version
- Closing VA 65 77 6.6 11.9 12.7
- P.f. 0.82 0.98
- Closed VA 7.6 9.8 1.9 1.6 3.9
- P.f. 0.25 0.86 0.79 0.51
• AC operation, 50/60 Hz, standard version
- Closing VA 68/67 81/79 6.6/6.7 11.9/12.0 12.7/14.7
- P.f. 0.72/0.74 0.98/0.98
- Closed VA 7.9/6.5 10.5/8.5 1.9/2.0 1.6/1.8 3.9/4.3
- P.f. 0.25/0.28 0.86/0.82 0.79/0.74 0.51/0.56
• AC operation, 50 Hz, for USA/Canada
- Closing VA 65 77 --
- P.f. 0.82 0.82 --
- Closed VA 73)/7.6 9.8 --
- P.f. 0.25 0.28 --
• AC operation, 60 Hz, for USA/Canada
- Closing VA 73 87 --
- P.f. 0.76 --
- Closed VA 7.2 9.4 --
- P.f. 0.28 --
• DC operation (closing = closed) W 5.9/5.9 5.9/1.4 10.2/1.3 14.3/1.9
Permissible residual current of the electronics
(with 0 signal)
• AC operation mA < 6 mA x (230 V/Us) < 7 mA x (230 V/Us)
• DC operation mA < 16 mA x (24 V/Us)
1) 2)
Coil operating range The following applies to Us max = 280 V: Upper limit = 1.1 x Us max
- At 50 Hz: 0.8 to 1.1 x Us 3)
Value applies to 3RT2023 contactor at 50 Hz AC.
- At 60 Hz: 0.85 to 1.1 x Us.

Coupling contactors
Type 3RT202.-.KB4.
Size S0
Control
Solenoid coil operating range 0.7 ... 1.25 x Us
Power consumption of the solenoid coils at Us 24 V DC W 4.5
(for cold coil)
Closing = Closed
Permissible residual current < 10 mA x (24 V/Us)
of the electronics (with 0 signal)
Overvoltage configuration of the solenoid coil Integrated varistor

Siemens IC 10 · 2023 3/33


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT2023 3RT2024 3RT2025 3RT2026 3RT2027 3RT2028
Size S0
Rated data of the main contacts
Load rating with AC
Utilization category AC-3 and AC-3e
• Rated operational currents Ie Up to 400 V A 9 12 17 25 32 38
440 V A 9 12 17 22 32 35
3

500 V A 9 12 17 18 32
690 V A 9 13 21
• Rated power for slip-ring or squirrel-cage motors at 230 V kW 2.2 3 4 5.5 7.5 11
at 50 and 60 Hz 400 V kW 4 5.5 7.5 11 15 18.5
690 V kW 7.5 11 18.5
Thermal load capacity 10 s current A 80 110 150 200 260 304
Power loss per main conducting path at Ie/AC-3/ W 0.2 0.3 0.6 1.9 2.3 3.2
AC-3e/400 V
Utilization category AC-4 (at Ia = 6 x Ie)
• Maximum values:
- Rated operational current Ie Up to 400 V A 8.5 12.5 15.5 22
- Rated power for squirrel-cage motors at 50 Hz at 400 V kW 4 5.5 7.5 11
and 60 Hz
• The following applies to a contact endurance
of about 200 000 operating cycles:
- Rated operational currents Ie Up to 400 V A 4.1 5.5 7.7 9 12
690 V A 3.3 5.5 7.7 9 12
- Rated power for squirrel-cage motors at 50 Hz at 110 V kW 0.5 0.73 1 1.2 1.6
and 60 Hz 230 V kW 1.1 1.5 2 2.5 3.4
400 V kW 2 2.6 3.5 4.4 6
690 V kW 2.5 4.6 6 7.7 10.3

Contactors
Type 3RT2023 to 3RT2028
Size S0
Conductor cross-sections
Main conductors Screw terminals
(1 or 2 conductors can be connected)
2
• Solid or stranded mm 2 x (1 ... 2.5)1); 2 x (2.5 ... 10)1)
2
• Finely stranded with end sleeve (DIN 46228) mm 2 x (1 ... 2.5)1); 2 x (2.5 ... 6)1); 1 x 10
• AWG cables, solid or stranded AWG 2 x (16 ... 12)1); 2 x (14 ... 8)1)
• Terminal screws M4 (for Pozidriv size 2;  5 ... 6 mm)
- Tightening torque Nm 2 ... 2.5 (18 ... 22 lb.in)
Auxiliary conductors
(1 or 2 conductors can be connected)
• Solid or stranded mm2 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1
2
• Finely stranded with end sleeve (DIN 46228) mm 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1)
• AWG cables, solid or stranded AWG 2 x (20 ... 16)1); 2 x (18 ... 14)1)
• Terminal screws M3 (for Pozidriv size 2;  5 ... 6 mm)
- Tightening torque Nm 0.8 ... 1.2 (7 ... 10.3 lb.in)
Main conductors2) Spring-loaded terminals
(1 or 2 conductors can be connected)
• Operating devices mm 3.0 x 0.5
• Solid or stranded mm2 2 x (1 ... 10)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (1 ... 6)
• Finely stranded without end sleeve mm2 2 x (1 ... 6)
• AWG cables, solid or stranded AWG 2 x (18 ... 8)
Auxiliary conductors2)
(1 or 2 conductors can be connected)
• Operating devices 3.0 x 0.5
• Solid or stranded mm2 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
1) 2)
If two different conductor cross-sections are connected to one clamping Max. outer diameter of the conductor insulation: 6.4 mm.
point, both cross-sections must lie in one of the ranges specified. On spring-loaded terminals with conductor cross-sections  1 mm2, an
insulation stop is recommended, see page 3/115.

3/34 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT2035 3RT2036 3RT2037 3RT2038
Size S2
General data
Dimensions (W x H x D)
• Basic unit
- Screw/spring-loaded terminals mm 55 x 114 x 130

H
• Basic unit with mounted auxiliary switch

3
D
- Screw terminals W mm 55 x 114 x 174
- Spring-loaded terminals mm 55 x 114 x 178
• Basic unit with mounted function module or
solid-state time-delayed auxiliary switch
- Screw/spring-loaded terminals mm 55 x 114 x 204
Permissible mounting position
The contactors are designed for operation on

NSB0_00478c
360° 22,5° 22,5°
a vertical mounting surface.

Upright mounting position

NSB0_00477a
Special version required
Mechanical endurance
• Basic units and Operat- 10 million (3RT203.-.S.30: 5 million)
basic units with mounted auxiliary switch ing
cycles
• Basic units with solid-state compatible auxiliary switch Operat- 5 million
ing
cycles
Electrical endurance For contact endurance of the main contacts, see page 3/28.
Rated insulation voltage Ui (pollution degree 3) V 690
Rated impulse withstand voltage Uimp
• Auxiliary circuit kV 6
• Main circuit kV 6
Protective separation between the coil and the main contacts V 400
(according to IEC 60947-1, Annex N)
Mirror contacts
A mirror contact is an auxiliary NC contact that cannot be closed
simultaneously with an NO main contact.
• Integrated auxiliary switches Yes, according to IEC 60947-4-1, Annex F
• 3RT2.3. (removable auxiliary switch) Yes, according to IEC 60947-4-1, Annex F
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -55 ... +80
Short-circuit protection
Main circuit
• Fuse links, operational class gG:
LV HRC, type 3NA; DIAZED, type 5SB; NEOZED, type 5SE
according to IEC 60947-4-1
- Type of coordination "1" A 160 250
- Type of coordination "2" A 80 125 160
- Weld-free (test conditions according to IEC 60947-4-1) A 16 25 50
Auxiliary circuit
• Fuse links, operational class gG: A 10
DIAZED, type 5SB; NEOZED, type 5SE
(weld-free protection at Ik  1 kA)
• 230 V miniature circuit breaker, C characteristic A 10
(short-circuit current Ik < 400 A)
Short-circuit protection for contactors with overload relays See Configuration Manual for load feeders
Short-circuit protection for fuseless load feeders See 3RA2 load feeders, page 8/5 onwards

Siemens IC 10 · 2023 3/35


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors Coupling
contactors
Type 3RT203.-.A..., 3RT203.-.N.3. 3RT203.-.S.3. 3RT203.-.KB4.
3RT203.-.C...
Size S2
Control
Type of operating mechanism AC AC/DC DC
Solenoid coil operating range
3

• AC operation1) 0.8 ... 1.1 x Us --


• AC/DC operation1) -- 0.8 ... 1.1 x Us --
• DC operation -- 0.8 ... 1.2 x Us
Power consumption of the solenoid coils
(for cold coil and 1.0 x Us)
• AC operation, 50 Hz, standard version
- Closing VA 190 --
- P.f. 0.72 --
- Closed VA 16 --
- P.f. 0.37 --
• AC operation, 50/60 Hz, standard version
- Closing VA 210/188 --
- P.f. 0.69/0.65 --
- Closed VA 17.2/16.5 --
- P.f. 0.36/0.39 --
• AC operation, 60 Hz, for USA/Canada
- Closing VA 212 --
- P.f. 0.67 --
- Closed VA 18.5 --
- P.f. 0.37 --
• AC/DC operation
- Closing for AC operation VA -- 40 --
- P.f. -- 0.95 --
- Closed for AC operation VA -- 2 --
- P.f. -- 0.95 0.7 --
- Closing for DC operation VA -- 232) 40 --
- Closed for DC operation VA -- 1 1.6 --
• DC operation
- Closing for DC operation W -- 21.53)
- Closed for DC operation W -- 1
Permissible residual current of the electronics
(with 0 signal)
• AC/DC operation mA -- < 20 --
• DC operation mA -- < 20
Overvoltage configuration of the solenoid coil -- Integrated varistor

U
PLC control input according to IEC 60947-1
• Solid-state operating mechanism -- Type 1 --
• Rated voltage V DC -- 24 --
• Operating range V DC -- 17 ... 30 --
• Power consumption mA --  30 --
• Recovery time after mains failure, typical s -- 2 --
1) Coil operating range
- At 50 Hz: 0.8 to 1.1 x Us,
- At 60 Hz: 0.85 to 1.1 x Us.
2)
In the case of AC/DC coils, increased pickup currents (2.6 A on average)
arise during the first 230 ms. For direct control by PLC, we therefore
recommend special coupling contactors with reduced power
consumption. The connection of one 3RT203.-.KB4. coupling contactor is
possible per PLC output port with an output current of 2 A, see page 3/59.
3) In the case of DC coils, increased pickup currents (2.1 A on average) arise
during the first 230 ms.

3/36 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT2035 3RT2036 3RT2037 3RT2038
Size S2
Rated data of the main contacts
Load rating with AC
Utilization category AC-3 and AC-3e
• Rated operational currents Ie Up to 400 V A 41 51 65 80
440 V A 41 51 65 80

3
500 V A 41 51 65 80
690 V A 24 47 58
• Rated power for slip-ring or at 230 V kW 11 15 18.5 22
squirrel-cage motors at 50 and 60 Hz 400 V kW 18.5 22 30 37
690 V kW 22 37 45
Thermal load capacity 10 s current A 400 420 520 640
Power loss per main conducting path at Ie/AC-3/ W 2.2 4 3.8 5.7
AC-3e/400 V
Utilization category AC-4 (at Ia = 6 x Ie)
• Maximum values
- Rated operational current Ie Up to 400 V A 35 41 55
- Rated power for squirrel-cage motors at 400 V kW 18.5 22 30
at 50 Hz and 60 Hz
• The following applies to a contact
endurance of about 200 000 operating
cycles:
- Rated operational currents Ie Up to 400 V A 22 24 28 30
690 V A 18.5 20 22 24
- Rated power for squirrel-cage motors at 110 V kW 3.2 3.5 4.1 4.3
at 50 Hz and 60 Hz 230 V kW 6.7 7.3 8.5 9.1
400 V kW 11.6 12.6 14.7 15.8
690 V kW 16.8 18.2 20 21.8

Contactors
Type 3RT2035 to 3RT2038
Size S2
Conductor cross-sections
Main conductors Screw terminals
(1 or 2 conductors can be connected)
• Solid or stranded mm2 2 x (1 ... 35)1); 1 x (1 ... 50)1)
2
• Finely stranded with end sleeve (DIN 46228) mm 2 x (1 ... 25)1); 1 x (1 ... 35)1)
• AWG cables, solid or stranded AWG 2 x (18 ... 2)1); 1 x (18 ... 1)1)
• Terminal screws Pozidriv size 2;  5 ... 6 mm
- Tightening torque Nm 3 ... 4.5 (27 ... 40 lb.in)
Auxiliary conductors and control conductors
(1 or 2 conductors can be connected)
• Solid or stranded mm2 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1)
2
• Finely stranded with end sleeve (DIN 46228) mm 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1)
• AWG cables, solid or stranded AWG 2 x (20 ... 16)1); 2 x (18 ... 14)1)
• Terminal screws M3 (for Pozidriv size 2;  5 ... 6 mm)
- Tightening torque Nm 0.8 ... 1.2 (7 ... 10.3 lb.in)
Auxiliary and control conductors2) Spring-loaded terminals
(1 or 2 conductors can be connected)
• Operating devices mm 3.0 x 0.5
• Solid or stranded mm2 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
1) 2)
If two different conductor cross-sections are connected to one clamping Max. outer diameter of the conductor insulation: 3.6 mm.
point, both cross-sections must lie in one of the ranges specified. On spring-loaded terminals with conductor cross-sections  1 mm2, an
insulation stop is recommended, see page 3/115.

Siemens IC 10 · 2023 3/37


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT2045 3RT2046 3RT2047
Size S3
General data
Dimensions (W x H x D)
• Basic unit
- Screw/spring-loaded terminals mm 70 x 140 x 152

H
• Basic unit with mounted auxiliary switch
3

D
- Screw terminals W mm 70 x 140 x 196
- Spring-loaded terminals mm 70 x 140 x 200
• Basic unit with mounted function module or
solid-state time-delayed auxiliary switch
- Screw/spring-loaded terminals mm 70 x 140 x 226
Permissible mounting position
The contactors are designed for operation on

NSB0_00478c
360° 22,5° 22,5°
a vertical mounting surface.

Upright mounting position

NSB0_00477a
Special version required
Mechanical endurance
• Basic units and Operat- 10 million
basic units with mounted auxiliary switch ing
cycles
• Basic units with solid-state compatible auxiliary switch Operat- 5 million
ing
cycles
Electrical endurance For contact endurance of the main contacts, see page 3/28.
Rated insulation voltage Ui (pollution degree 3) V 1 000 (3RT20..-.....-0CC0: 690)
Rated impulse withstand voltage Uimp
• Auxiliary circuit kV 6
• Main circuit kV 8
Protective separation between the coil and the main contacts V 690
(according to IEC 60947-1, Annex N)
Mirror contacts
A mirror contact is an auxiliary NC contact that cannot be closed
simultaneously with an NO main contact.
• Integrated auxiliary switches Yes, according to IEC 60947-4-1, Annex F
• 3RT2.4. (removable auxiliary switch) Yes, according to IEC 60947-4-1, Annex F
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -55 ... +80
Short-circuit protection
Main circuit
• Fuse links, operational class gG:
LV HRC, type 3NA; DIAZED, type 5SB; NEOZED, type 5SE
according to IEC 60947-4-1
- Type of coordination "1" A 250
- Type of coordination "2" A 160 160 200
- Weld-free (test conditions according to IEC 60947-4-1) A On request
Auxiliary circuit
• Fuse links, operational class gG: A 10
DIAZED, type 5SB; NEOZED, type 5SE
(weld-free protection at Ik  1 kA)
• 230 V miniature circuit breaker, C characteristic A 10
(short-circuit current Ik < 400 A)
Short-circuit protection for contactors with overload relays See Configuration Manual for load feeders
Short-circuit protection for fuseless load feeders See 3RA2 load feeders, page 8/5 onwards

3/38 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors Coupling
contactors
Type 3RT204.-.A..., 3RT204.-.N.3. 3RT204.-.S.3. 3RT204.-.KB4.
3RT204.-.C...
Size S3
Control
Type of operating mechanism AC AC/DC DC
Solenoid coil operating range

3
• AC operation1) 0.8 ... 1.1 x Us --
• AC/DC operation1) -- 0.8 ... 1.1 x Us --
• DC operation -- 0.8 ... 1.2 x Us
Power consumption of the solenoid coils
(for cold coil and 1.0 x Us)
• AC operation, 50 Hz, standard version
- Closing VA 296 --
- P.f. 0.61 --
- Closed VA 19 --
- P.f. 0.38 --
• AC operation, 50/60 Hz, standard version
- Closing VA 348/296 --
- P.f. 0.62/0.55 --
- Closed VA 25/18 --
- P.f. 0.35/0.41 --
• AC operation, 60 Hz, for USA/Canada
- Closing VA 326 --
- P.f. 0.62 --
- Closed VA 22 --
- P.f. 0.38 --
• AC/DC operation
- Closing for AC operation VA -- 163 130 --
- P.f. -- 0.95 --
- Closed for AC operation VA -- 3.1 2.4 --
- P.f. -- 0.95 0.7 --
- Closing for DC operation VA -- 762) 130 --
- Closed for DC operation VA -- 1.8 --
• DC operation
- Closing for DC operation W -- 253)
- Closed for DC operation W -- 0.9
Permissible residual current of the electronics
(with 0 signal)
• AC/DC operation mA -- < 20 --
• DC operation mA -- < 20
Overvoltage configuration of the solenoid coil -- Integrated varistor

PLC control input according to IEC 60947-1


• Solid-state operating mechanism -- Type 1 --
• Rated voltage V DC -- 24 --
• Operating range V DC -- 17 ... 30 --
• Power consumption mA --  30 --
• Recovery time after mains failure, typical s -- 2 --
1)
Coil operating range
- at 50 Hz: 0.8 to 1.1 x Us
- at 60 Hz: 0.85 to 1.1 x Us.
2)
In the case of AC/DC coils, increased pickup currents (6.5 A on average)
arise during the first 150 ms. For direct control by PLC, we therefore
recommend special coupling contactors with reduced power
consumption. The connection of one 3RT204.-.KB4. coupling contactor is
possible per PLC output port with an output current of 2 A, see page 3/59.
3)
In the case of DC coils, increased pickup currents (2.1 A on average) arise
during the first 150 ms.

Siemens IC 10 · 2023 3/39


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT2045 3RT2046 3RT2047
Size S3
Rated data of the main contacts
Load rating with AC
Utilization category AC-3 and AC-3e
• Rated operational currents Ie Up to 400 V A 80 95 110
500 V A 80 95 110
3

690 V A 58 78 98
1 000 V A 30
• Rated power for slip-ring at 230 V kW 22 22 30
or squirrel-cage motors 400 V kW 37 45 55
at 50 and 60 Hz 690 V kW 55 75 90
1 000 V kW 37
Thermal load capacity 10 s current A 760 880
Power loss per main conducting path at Ie/AC-3/ W 5.3 6.6 7.9
AC-3e/400 V
Utilization category AC-4 (at Ia = 6 x Ie)
• Maximum values
- Rated operational current Ie Up to 400 V A 66 80 97
- Rated power for squirrel-cage at 400 V kW 37 45 55
motors at 50 Hz and 60 Hz
• The following applies to a contact endurance
of about 200 000 operating cycles:
- Rated operational currents Ie Up to 400 V A 34 42 46
690 V A 24 30 36
- Rated power for squirrel-cage at 110 V kW 4.9 6.1 6.7
motors at 50 Hz and 60 Hz 230 V kW 10.4 12 14
400 V kW 17.9 22 24.3
690 V kW 21.8 27.4 32.9

Contactors
Type 3RT2045 to 3RT2047
Size S3
Conductor cross-sections
Main conductors Screw terminals
(1 or 2 conductors can be connected)
• Solid mm2 2 x (2.5 ... 16)1)
• Stranded mm2 2 x (6 ... 16)1); 2 x (10 ... 50)1); 1 x (10 ... 70)1)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (2.5 ...35)1); 1 x (2.5 ... 50)1)
• AWG cables, solid or stranded AWG 2 x (10 ... 1/0)1); 1 x (10 ... 2/0)1)
• Terminal screws Hexagon socket, size 4
- Tightening torque Nm 4.5 ... 6 (40 ... 53 lb.in)
Auxiliary conductors and control conductors
(1 or 2 conductors can be connected)
• Solid or stranded mm2 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1)
• AWG cables, solid or stranded AWG 2 x (20 ... 16)1); 2 x (18 ... 14)1)
• Terminal screws M3 (for Pozidriv size 2;  5 ... 6 mm)
- Tightening torque Nm 0.8 ... 1.2 (7 ... 10.3 lb.in)
2)
Auxiliary and control conductors Spring-loaded terminals
(1 or 2 conductors can be connected)
• Operating devices mm 3.0 x 0.5
• Solid or stranded mm2 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 16)
1) 2)
If two different conductor cross-sections are connected to one clamping Max. outer diameter of the conductor insulation: 3.6 mm.
point, both cross-sections must lie in one of the ranges specified. On spring-loaded terminals with conductor cross-sections  1 mm2, an
insulation stop is recommended, see page 3/115.

3/40 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT1054 3RT1055, 3RT1064 to 3RT1075 3RT1076
3RT1056 3RT1066
Size S6 S10 S12
General data
Dimensions (W x H x D) :
• Basic unit mm 120 x 172 x 170 145 x 210 x 202 160 x 214 x 225
• Basic unit with mounted auxiliary switch mm 120 x 172 x 217 145 x 210 x 251 160 x 214 x 271

3
+

'
Permissible mounting position

NSB0_00649a
22,5° 22,5°
The contactors are designed for operation on a vertical 90° 90°
mounting surface.

Mechanical endurance Operat- 10 million


ing
cycles
Electrical endurance For contact endurance of the main contacts, see page 3/28.
Rated insulation voltage Ui V 1 000
(pollution degree 3)
Rated impulse withstand voltage Uimp
• Auxiliary circuit kV 6
• Main circuit kV 8
Protective separation between the coil and the main V 690
contacts according to IEC 60947-1, Annex N
Mirror contacts Yes, according to IEC 60947-4-1, Annex F
A mirror contact is an auxiliary NC contact that cannot be
closed simultaneously with an NO main contact.
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -55 ... +80
Electromagnetic compatibility (EMC) See page 3/21
Short-circuit protection
Main circuit
Fuse links, operational class gG:
LV HRC, type 3NA; DIAZED, type 5SB; NEOZED, type 5SE
according to IEC 60947-4-1
• Type of coordination "1" A 355 500 630
• Type of coordination "2" A 250 315 400 500
• Weld-free A 80 160 250 315
Auxiliary circuit
Short-circuit test
• With fuse links of operational class gG: A 10
DIAZED, type 5SB; NEOZED, type 5SE
with short-circuit current Ik = 1 kA according to IEC 60947-5-1
• With miniature circuit breakers with C characteristic A 10
with short-circuit current Ik = 400 A
Short-circuit protection for contactors with overload relays See Configuration Manual for load feeders

Siemens IC 10 · 2023 3/41


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT105. 3RT106. 3RT107.
Size S6 S10 S12
Control
Operating range of the solenoid AC/DC 0.8 x Us min ... 1.1 x Us max
operating mechanism
Power consumption of the solenoid operating mechanism
(with cold coil and rated range Us min ... Us max)
3

• Standard operating mechanism


(3RT10..-.A)
- AC operation Closing at Us min VA/p.f. 250/0.9 490/0.9 700/0.9
Closing at Us max VA/p.f. 300/0.9 590/0.9 830/0.9
Closed at Us min VA/p.f. 4.8/0.8 5.6/0.9 7.6/0.9
Closed at Us max VA/p.f. 5.8/0.8 6.7/0.9 9.2/0.9
- DC operation Closing at Us min W 300 540 770
Closing at Us max W 360 650 920
Closed at Us min W 4.3 6.1 8.5
Closed at Us max W 5.2 7.4 10
• Solid-state operating mechanism
(3RT10..-.N/-.P/-.S)
- AC operation Closing at Us min VA/p.f. 190/0.8 400/0.8 560/0.8
Closing at Us max VA/p.f. 280/0.8 530/0.8 750/0.8
Closed at Us min VA/p.f. 3.5/0.6 5.5/0.5 5.6/0.5
Closed at Us max VA/p.f. 4.8/0.6 8.5/0.4 9/0.4
- DC operation Closing at Us min W 250 440 600
Closing at Us max W 320 580 800
Closed at Us min W 2.1 2.8 3
Closed at Us max W 2.8 3.4 3.6
PLC control input according to IEC 60947-1
• Solid-state operating mechanism 3RT10..-.N/-.P Type 2
3RT10..-.S Type 1
• Rated voltage V DC 24
• Operating range V DC 17 ... 30
• Power consumption mA  30
• Recovery time after mains failure, typical s 2
(applicable only for fail-safe version 3RT10..-.S)

3/42 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT1054 3RT1055 3RT1056 3RT1064 3RT1065 3RT1066 3RT1075 3RT1076
Size S6 S10 S12
Rated data of the main contacts
Load rating with AC
Utilization category AC-3 and AC-3e
• Rated operational currents Ie

3
- Up to 500 V A 115 150 185 225 265 300 400 500
- At 690 V A 115 150 170 225 265 280 400 450
- At 1 000 V A 53 65 65 68 95 95 180 180
• Rated power for slip-ring or squirrel-cage motors
at 50 and 60 Hz
- At 230 V kW 37 45 55 55 75 90 132 160
- At 400 V kW 55 75 90 110 132 160 200 250
- At 500 V kW 75 90 132 160 160 200 250 315
- At 690 V kW 110 132 160 On request On request On request 400 400
- At 1 000 V kW 75 90 160 200 132 132 250 250
Thermal load capacity, 10 s current A 1 100 1 300 1 480 1 800 2 400 3 200 4 000
Power loss per main conducting path W 7 9 13 17 18 22 35 55
at Ie/AC-3/AC-3e/400 V
Utilization category AC-4 (at Ia = 6 x Ie)
Maximum values:
• Rated operational current Ie
- Up to 400 V A 97 132 160 195 230 280 350 430
• Rated power for squirrel-cage motors at
50 Hz and 60 Hz
- At 400 V kW 55 75 90 110 132 160 200 250
The following applies to a contact endurance
of about 200 000 operating cycles:
• Rated operational currents Ie
- Up to 500 V A 54 68 81 96 117 125 150 175
- Up to 690 V A 48 57 65 85 105 115 135 150
• Rated power for squirrel-cage motors at
50 Hz and 60 Hz
- At 230 V kW 16 20 25 30 37 40 48 56
- At 400 V kW 29 38 45 54 66 71 85 98
- At 500 V kW 37 47 57 67 82 87 105 123
- At 690 V kW 48 55 65 82 102 112 133 148

Siemens IC 10 · 2023 3/43


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT105. 3RT106. 3RT107.
Size S6 S10 S12
Conductor cross-sections
Main conductors (1 or 2 conductors can be connected) Screw terminals

With mounted box terminals Type 3RT1955-4G (55 kW) 3RT1956-4G 3RT1966-4G
• Terminal screws M10 (hexagon socket, A/F 4) M12 (hexagon socket, A/F 5)
3

- Tightening torque Nm 10 ... 12 20 ... 22


lb.in 90 ... 110 180 ... 195
Front clamping point connected
• Finely stranded with end sleeve (DIN 46228) mm2 16 ... 70 16 ... 120 70 ... 240
mm2
NSB0_00479

• Finely stranded without end sleeve 16 ... 70 16 ... 120 70 ... 240
• Stranded mm2 16 ... 70 16 ... 120 95 ... 300
• AWG cables, solid or stranded AWG 6 ... 2/0 6 ... 250 kcmil 3/0 ... 600 kcmil
• Ribbon cable conductors mm Min. 3 x 9 x 0.8, Min. 3 x 9 x 0.8, Min. 6 x 9 x 0.8,
(number x width x thickness) max. 6 x 15.5 x 0.8 max. 10 x 15.5 x 0.8 max. 20 x 24 x 0.5
Rear clamping point connected
• Finely stranded with end sleeve (DIN 46228) mm2 16 ... 70 16 ... 120 120 ... 185
NSB0_00480

• Finely stranded without end sleeve mm2 16 ... 70 16 ... 120 120 ... 185
• Stranded mm2 16 ... 70 16 ... 120 120 ... 240
• AWG cables, solid or stranded AWG 6 ... 2/0 6 ... 250 kcmil 250 ... 500 kcmil
• Ribbon cable conductors mm Min. 3 x 9 x 0.8, Min. 3 x 9 x 0.8, Min. 6 x 9 x 0.8,
(number x width x thickness) max. 6 x 15.5 x 0.8 max. 10 x 15.5 x 0.8 max. 20 x 24 x 0.5
Both clamping points connected
(minimum cross-section 16 mm²)
• Finely stranded with end sleeve (DIN 46228) mm2 Max. 1 x 50, 1 x 70 Max. 1 x 95, 1 x 120 Min. 2 x 50, max. 2 x 185
• Finely stranded without end sleeve mm2 Max. 1 x 50, 1 x 70 Max. 1 x 95, 1 x 120 Min. 2 x 50, max. 2 x 185
NSB0_00481

• Stranded mm2 Max. 1 x 50, 1 x 70 Max. 1 x 95, 1 x 120 Min. 2 x 70, max. 2 x 240
• AWG cables, solid or stranded AWG Max. 2 x 1/0 Max. 2 x 3/0 Min. 2 x 2/0,
max. 2 x 500 kcmil
• Ribbon cable conductors mm Max. 2 x (6 x 15.5 x 0.8) Max. 2 x (10 x 15.5 x 0.8) Max. 2 x (20 x 24 x 0.5)
(number x width x thickness)
Busbar connections
Connecting bar (max. width) mm 17 25
Cable lug connection
• Finely stranded with cable lug1)2) mm2 16 ... 95 50 ... 240
• Stranded with cable lug1)2) mm2 25 ... 120 70 ... 240
• AWG cables, solid or stranded AWG 4 ... 250 kcmil 2/0 ... 500 kcmil
• Terminal screws M8 x 25 (A/F 13) M10 x 30 (A/F 17)
- Tightening torque Nm 10 ... 14 14 ... 24
lb.in 90 ... 124 124 ... 210
Auxiliary conductors (1 or 2 conductors can be connected)
• Solid mm2 2 x (0.5 ... 1.5)3); 2 x (0.75 ... 2.5)3); max. 2 x (0.75 ... 4)3)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)3); 2 x (0.75 ... 2.5)3)
• AWG cables, solid or stranded AWG 2 x (18 ... 14)
• Terminal screws M3 (Pozidriv size 2)
- Tightening torque Nm 0.8 ... 1.2
lb.in 7 ... 10.3
Auxiliary conductors4) (1 or 2 conductors can be connected) Spring-loaded terminals

• Operating devices 3.0 x 0.5; 3.5 x 0.5


• Solid mm2 2 x (0.25 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.25 ... 2.5)
• AWG cables, solid or stranded AWG 2 x (24 ... 14)
1) 3)
3RT105.: When using cable lugs according to DIN 46235, use the If two different conductor cross-sections are connected to one clamping
3RT1956-4EA1 terminal cover for conductor cross-sections from 95 mm2 point, both cross-sections must lie in one of the ranges specified.
to maintain the phase clearance; see page 3/112. 4)
Max. outer diameter of the conductor insulation: 3.6 mm.
2)
3RT106. and 3RT107.: When connecting cable lugs according to On spring-loaded terminals with conductor cross-sections  1 mm2, an
DIN 46234 for conductor cross-sections larger than 240 mm2 and insulation stop is recommended, see page 3/115.
according to DIN 46235 for conductor cross-sections larger than 185 mm2,
the 3RT1966-4EA1 terminal cover is required to maintain the phase
clearance, see page 3/112.

3/44 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW
Data for North America
Contactors
Type 3RT2015 3RT2016 3RT2017 3RT2018
Size S00
s and u rated data
Rated operational voltage V AC 600
Uninterrupted current, at 40 °C, open and enclosed A 20
Maximum horsepower ratings

3
(from s and u approved values)
• Rated power for three-phase motors at 200 V hp 1.5 2 3
at 60 Hz 230 V hp 2 3 5
460 V hp 3 5 7.5 10
575 V hp 5 7.5 10
Short-circuit protection at 600 V kA 5
(contactor)
• Class J fuse A 60
(values for RK5 fuses available on request)
• Circuit breakers in accordance with UL 489 A 50
("Inverse Time Breakers")
• Combination Motor Controllers (Type E) 3RV2.1 or 3RV2.2
according to UL 508 and UL 60947-4-1

Contactors
Type 3RT2023 3RT2024 3RT2025 3RT2026 3RT2326-.....-4AA0 3RT2027 3RT2028
Size S0
s and u rated data
Rated operational voltage V AC 600
Uninterrupted current, at 40 °C, open and enclosed A 30 42
Maximum horsepower ratings
(from s and u approved values)
• Rated power for three-phase motors at 200 V hp 2 3 5 3 10
at 60 Hz 230 V hp 3 5 7.5 5 10
460 V hp 5 7.5 10 15 10 20 25
575 V hp 7.5 10 15 20 15 25
Short-circuit protection at 600 V kA 5
(contactor)
• Class J fuse A 125 150
(values for RK5 fuses available on request)
• Circuit breakers in accordance with UL 489 A 70 100
("Inverse Time Breakers")
• Combination Motor Controllers (Type E) at 480 V Type 3RV202
according to UL 508 and UL 60947-4-1 at 600 V Type 3RV202

Contactors
Type 3RT2035 3RT2036, 3RT2037 3RT2038 3RT2045 3RT2046 3RT2047
3RT2336-.....-4AA0
Size S2 S3
s and u rated data
Rated operational voltage V AC 600
Uninterrupted current, at 40 °C, open and enclosed A 55 60 80 90 62 77 99
Maximum horsepower ratings
(from s and u approved values)
• Rated power for three-phase motors at 200/208 V hp 10 15 20 25 30
at 60 Hz 230/240 V hp 15 20 25 30 40
460/480 V hp 30 40 50 60 75
575/600 V hp 40 50 60 60 75 100
Short-circuit protection at 600 V kA 5 10 10
(contactor)
• RK5 fuse A 150 200 250 300 350
• Combination Motor Controllers (Type E) Type 3RV203 3RV204
according to UL 508 and UL 60947-4-1

Siemens IC 10 · 2023 3/45


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

Contactors
Type 3RT1054 3RT1055 3RT1056 3RT1064 3RT1065 3RT1066 3RT1075 3RT1076
Size S6 S10 S12
s and u rated data
Rated operational voltage V AC 600
Uninterrupted current, at 40 °C, open and A 140 195 250 330 400 540
enclosed
Maximum horsepower ratings
3

(from s and u approved values)


• Rated power for three-phase at 200 V hp 40 50 60 75 100 125 150
motors 230 V hp 50 60 75 100 125 150 200
at 60 Hz 460 V hp 100 125 150 200 250 300 400
575 V hp 125 150 200 250 300 400 500
Short-circuit protection For more information, see Certificate of Compliance for the individual devices.
For the dimensioning of load feeders, see Configuration Manual.

Contactors
Type 3RT201 3RT202 to 3RT204 3RT105 to 3RT107
Size S00 S0 to S3 S6 to S12
Integrated or Integrated Mountable auxiliary Mountable auxiliary
mountable auxiliary switch switch
switch
s and u rated data of the auxiliary contacts
Rated voltage V AC 600
Switching capacity A 600, Q 600 A 600, P 600 A 600, Q 600 A 600, Q 600
• Uninterrupted current at 240 V AC A 10

3/46 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors, 3-pole up to 250 kW

■ Selection and ordering data


AC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RT201.-1A... 3RT201.-2A... 3RT201.-1AP04-3MA0 3RT201.-2AP04-3MA0
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded
AC-3 and AC-3e, AC-1, supply terminals
tu: 60 °C tu: 40 °C voltage Us
Opera- Ratings of Opera- Ident. Version 50/60 Hz AC
tional three-phase tional No.
current Ie motors at current Ie Article No. Price Article No. Price
up to 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
7 3 18 10 1 -- 24 3RT2015-1AB01 3RT2015-2AB01
110 3RT2015-1AF01 3RT2015-2AF01
230 3RT2015-1AP01 3RT2015-2AP01
01 -- 1 24 3RT2015-1AB02 3RT2015-2AB02
110 3RT2015-1AF02 3RT2015-2AF02
230 3RT2015-1AP02 3RT2015-2AP02
9 4 22 10 1 -- 24 3RT2016-1AB01 3RT2016-2AB01
110 3RT2016-1AF01 3RT2016-2AF01
230 3RT2016-1AP01 3RT2016-2AP01
01 -- 1 24 3RT2016-1AB02 3RT2016-2AB02
110 3RT2016-1AF02 3RT2016-2AF02
230 3RT2016-1AP02 3RT2016-2AP02
12 5.5 22 10 1 -- 24 3RT2017-1AB01 3RT2017-2AB01
110 3RT2017-1AF01 3RT2017-2AF01
230 3RT2017-1AP01 3RT2017-2AP01
01 -- 1 24 3RT2017-1AB02 3RT2017-2AB02
110 3RT2017-1AF02 3RT2017-2AF02
230 3RT2017-1AP02 3RT2017-2AP02
16 7.5 22 10 1 -- 24 3RT2018-1AB01 3RT2018-2AB01
110 3RT2018-1AF01 3RT2018-2AF01
230 3RT2018-1AP01 3RT2018-2AP01
01 -- 1 24 3RT2018-1AB02 3RT2018-2AB02
110 3RT2018-1AF02 3RT2018-2AF02
230 3RT2018-1AP02 3RT2018-2AP02
With permanently mounted auxiliary switch
7 3 18 22 2 2 230 3RT2015-1AP04-3MA0 3RT2015-2AP04-3MA0
9 4 22 22 2 2 230 3RT2016-1AP04-3MA0 3RT2016-2AP04-3MA0
12 5.5 22 22 2 2 230 3RT2017-1AP04-3MA0 3RT2017-2AP04-3MA0
16 7.5 22 22 2 2 230 3RT2018-1AP04-3MA0 3RT2018-2AP04-3MA0
With permanently mounted auxiliary switch and varistor plugged
into the front
7 3 18 22 2 2 230 3RT2015-1CP04-3MA0 3RT2015-2CP04-3MA0
9 4 22 22 2 2 230 3RT2016-1CP04-3MA0 3RT2016-2CP04-3MA0
12 5.5 22 22 2 2 230 3RT2017-1CP04-3MA0 3RT2017-2CP04-3MA0
16 7.5 22 22 2 2 230 3RT2018-1CP04-3MA0 3RT2018-2CP04-3MA0

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/47
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
AC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RT202.-1A.00 3RT202.-2A.00
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded terminals
AC-3 and AC-3e, AC-1, supply voltage
tu: 60 °C tu: 40 °C Us
Opera- Ratings of three- Opera- Ident. Version 50 Hz AC
tional phase motors at tional No.
current Ie 50 Hz and current Ie Article No. Price Article No. Price
up to up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S0
9 4 40 11 1 1 24 3RT2023-1AB00 3RT2023-2AB00
110 3RT2023-1AF00 3RT2023-2AF00
230 3RT2023-1AP00 3RT2023-2AP00
12 5.5 40 11 1 1 24 3RT2024-1AB00 3RT2024-2AB00
110 3RT2024-1AF00 3RT2024-2AF00
230 3RT2024-1AP00 3RT2024-2AP00
17 7.5 40 11 1 1 24 3RT2025-1AB00 3RT2025-2AB00
110 3RT2025-1AF00 3RT2025-2AF00
230 3RT2025-1AP00 3RT2025-2AP00
25 11 40 11 1 1 24 3RT2026-1AB00 3RT2026-2AB00
110 3RT2026-1AF00 3RT2026-2AF00
230 3RT2026-1AP00 3RT2026-2AP00
32 15 50 11 1 1 24 3RT2027-1AB00 3RT2027-2AB00
110 3RT2027-1AF00 3RT2027-2AF00
230 3RT2027-1AP00 3RT2027-2AP00
38 18.5 50 11 1 1 24 3RT2028-1AB00 3RT2028-2AB00
110 3RT2028-1AF00 3RT2028-2AF00
230 3RT2028-1AP00 3RT2028-2AP00

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


3/48 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors, 3-pole up to 250 kW
AC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RT202.-1A.04 3RT202.-2A.04 3RT202.-1CL24-3MA0 3RT202.-2CL24-3MA0
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded
AC-3 and AC-3e, AC-1, supply voltage terminals
tu: 60 °C tu: 40 °C Us
Opera- Ratings of Opera- Ident. Version 50 Hz AC
tional three-phase tional No.
current Ie motors at current Ie Article No. Price Article No. Price
up to 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S0
With removable auxiliary switch
9 4 40 22 2 2 24 3RT2023-1AB04 3RT2023-2AB04
230 3RT2023-1AP04 3RT2023-2AP04
12 5.5 40 22 2 2 24 3RT2024-1AB04 3RT2024-2AB04
110 3RT2024-1AF04 3RT2024-2AF04
230 3RT2024-1AP04 3RT2024-2AP04
17 7.5 40 22 2 2 24 3RT2025-1AB04 3RT2025-2AB04
110 3RT2025-1AF04 3RT2025-2AF04
230 3RT2025-1AP04 3RT2025-2AP04
25 11 40 22 2 2 24 3RT2026-1AB04 3RT2026-2AB04
110 3RT2026-1AF04 3RT2026-2AF04
230 3RT2026-1AP04 3RT2026-2AP04
32 15 50 22 2 2 24 3RT2027-1AB04 3RT2027-2AB04
110 3RT2027-1AF04 3RT2027-2AF04
230 3RT2027-1AP04 3RT2027-2AP04
38 18.5 50 22 2 2 24 3RT2028-1AB04 3RT2028-2AB04
110 3RT2028-1AF04 3RT2028-2AF04
230 3RT2028-1AP04 3RT2028-2AP04
With permanently mounted auxiliary switch and varistor plugged in
9 4 40 22 2 2 230 3RT2023-1CL24-3MA0 3RT2023-2CL24-3MA0
12 5.5 40 22 2 2 230 3RT2024-1CL24-3MA0 3RT2024-2CL24-3MA0
17 7.5 40 22 2 2 230 3RT2025-1CL24-3MA0 3RT2025-2CL24-3MA0
25 11 40 22 2 2 230 3RT2026-1CL24-3MA0 3RT2026-2CL24-3MA0
32 15 50 22 2 2 230 3RT2027-1CL24-3MA0 3RT2027-2CL24-3MA0
38 18.5 50 22 2 2 230 3RT2028-1CL24-3MA0 3RT2028-2CL24-3MA0

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/49
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
AC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RT203.-1A.00 3RT203.-3A.00 3RT203.-1A.04 3RT203.-3CL24-3MA0 3RT203.-1CL24-3MA0

Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded


AC-3 and AC-3e, AC-1, supply voltage terminals
tu: 60 °C tu: 40 °C Us
Opera- Ratings of Opera- Ident. Version 50 Hz AC
tional three-phase tional No.
current Ie motors at current Ie Article No. Price Article No. Price
up to 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S2
41 18.5 60 11 1 1 24 3RT2035-1AB00 3RT2035-3AB00
110 3RT2035-1AF00 3RT2035-3AF00
230 3RT2035-1AP00 3RT2035-3AP00
51 22 70 11 1 1 24 3RT2036-1AB00 3RT2036-3AB00
110 3RT2036-1AF00 3RT2036-3AF00
230 3RT2036-1AP00 3RT2036-3AP00
65 30 80 11 1 1 24 3RT2037-1AB00 3RT2037-3AB00
110 3RT2037-1AF00 3RT2037-3AF00
230 3RT2037-1AP00 3RT2037-3AP00
80 37 90 11 1 1 24 3RT2038-1AB00 3RT2038-3AB00
110 3RT2038-1AF00 3RT2038-3AF00
230 3RT2038-1AP00 3RT2038-3AP00
With removable auxiliary switch
41 18.5 60 22 2 2 24 3RT2035-1AB04 --
110 3RT2035-1AF04 --
230 3RT2035-1AP04 --
51 22 70 22 2 2 24 3RT2036-1AB04 --
110 3RT2036-1AF04 --
230 3RT2036-1AP04 --
65 30 80 22 2 2 24 3RT2037-1AB04 --
110 3RT2037-1AF04 --
230 3RT2037-1AP04 --
80 37 90 22 2 2 24 3RT2038-1AB04 --
110 3RT2038-1AF04 --
230 3RT2038-1AP04 --
With permanently mounted auxiliary switch and integrated coil circuit
(varistor plugged in at the factory)
41 18.5 60 22 2 2 230 3RT2035-1CL24-3MA0 3RT2035-3CL24-3MA0
51 22 70 22 2 2 230 3RT2036-1CL24-3MA0 3RT2036-3CL24-3MA0
65 30 80 22 2 2 230 3RT2037-1CL24-3MA0 3RT2037-3CL24-3MA0
80 37 90 22 2 2 230 3RT2038-1CL24-3MA0 3RT2038-3CL24-3MA0

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


3/50 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors, 3-pole up to 250 kW
AC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RT204.-1A.00 3RT204.-1A.04 3RT204.-1CL24-3MA0 3RT204.-3A.00
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded
AC-3 and AC-3e, AC-1, supply voltage terminals
tu: 60 °C tu: 40 °C Us
Opera- Ratings of Opera- Ident. Version 50 Hz AC
tional three-phase tional No.
current Ie motors at current Ie Article No. Price Article No. Price
up to 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35-15 and
TH 75-15 DIN rails
Size S3
80 37 125 11 1 1 24 3RT2045-1AB00 3RT2045-3AB00
110 3RT2045-1AF00 3RT2045-3AF00
230 3RT2045-1AP00 3RT2045-3AP00
95 45 130 11 1 1 24 3RT2046-1AB00 3RT2046-3AB00
110 3RT2046-1AF00 3RT2046-3AF00
230 3RT2046-1AP00 3RT2046-3AP00
110 55 130 11 1 1 24 3RT2047-1AB00 3RT2047-3AB00
110 3RT2047-1AF00 3RT2047-3AF00
230 3RT2047-1AP00 3RT2047-3AP00
With removable auxiliary switch
80 37 125 22 2 2 24 3RT2045-1AB04 --
110 3RT2045-1AF04 --
230 3RT2045-1AP04 --
95 45 130 22 2 2 24 3RT2046-1AB04 --
110 3RT2046-1AF04 --
230 3RT2046-1AP04 --
110 55 130 22 2 2 24 3RT2047-1AB04 --
110 3RT2047-1AF04 --
230 3RT2047-1AP04 --
With permanently mounted auxiliary switch and integrated coil circuit
(varistor plugged in at the factory)
80 37 125 22 2 2 230 3RT2045-1CL24-3MA0 --
95 45 130 22 2 2 230 3RT2046-1CL24-3MA0 --
110 55 130 22 2 2 230 3RT2047-1CL24-3MA0 --

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/51
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RT201.-1B... 3RT201.-2B...
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded terminals
AC-3 and AC-3e, AC-1, supply voltage
tu: 60 °C tu: 40 °C Us
Opera- Ratings of Opera- Ident. Version DC
tional three-phase tional No.
current Ie motors at current Ie Article No. Price Article No. Price
up to 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
7 3 18 10 1 -- 24 3RT2015-1BB41 3RT2015-2BB41
220 3RT2015-1BM41 3RT2015-2BM41
01 -- 1 24 3RT2015-1BB42 3RT2015-2BB42
220 3RT2015-1BM42 3RT2015-2BM42
9 4 22 10 1 -- 24 3RT2016-1BB41 3RT2016-2BB41
220 3RT2016-1BM41 3RT2016-2BM41
01 -- 1 24 3RT2016-1BB42 3RT2016-2BB42
220 3RT2016-1BM42 3RT2016-2BM42
12 5.5 22 10 1 -- 24 3RT2017-1BB41 3RT2017-2BB41
220 3RT2017-1BM41 3RT2017-2BM41
01 -- 1 24 3RT2017-1BB42 3RT2017-2BB42
220 3RT2017-1BM42 3RT2017-2BM42
16 7.5 22 10 1 -- 24 3RT2018-1BB41 3RT2018-2BB41
220 3RT2018-1BM41 3RT2018-2BM41
01 -- 1 24 3RT2018-1BB42 3RT2018-2BB42
220 3RT2018-1BM42 3RT2018-2BM42
With integrated coil circuit (varistor integrated at the factory)
7 3 18 10 1 -- 24 3RT2015-1UB41 3RT2015-2UB41
01 -- 1 24 3RT2015-1UB42 3RT2015-2UB42
9 4 22 10 1 -- 24 3RT2016-1UB41 3RT2016-2UB41
01 -- 1 24 3RT2016-1UB42 3RT2016-2UB42
12 5.5 22 10 1 -- 24 3RT2017-1UB41 3RT2017-2UB41
01 -- 1 24 3RT2017-1UB42 3RT2017-2UB42
16 7.5 22 10 1 -- 24 3RT2018-1UB41 3RT2018-2UB41
01 -- 1 24 3RT2018-1UB42 3RT2018-2UB42
With integrated coil circuit (diode integrated at factory)
7 3 18 10 1 -- 24 3RT2015-1FB41 3RT2015-2FB41
01 -- 1 24 3RT2015-1FB42 3RT2015-2FB42
9 4 22 10 1 -- 24 3RT2016-1FB41 3RT2016-2FB41
01 -- 1 24 3RT2016-1FB42 3RT2016-2FB42
12 5.5 22 10 1 -- 24 3RT2017-1FB41 3RT2017-2FB41
01 -- 1 24 3RT2017-1FB42 3RT2017-2FB42
16 7.5 22 10 1 -- 24 3RT2018-1FB41 3RT2018-2FB41
01 -- 1 24 3RT2018-1FB42 3RT2018-2FB42

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


3/52 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors, 3-pole up to 250 kW
DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RT201.-1BB44-3MA0 3RT201.-2BB44-3MA0 3RT201.-1BB4.-0CC0 3RT201.-2BB4.-0CC0
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded terminals
AC-3 and AC-3e, AC-1, supply
tu: 60 °C tu: 40 °C voltage Us
Opera- Ratings of Opera- Ident. Version DC
tional three-phase tional No.
current Ie motors at current Ie Article No. Price Article No. Price
up to 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
With permanently mounted auxiliary switch
7 3 18 22 2 2 24 3RT2015-1BB44-3MA0 3RT2015-2BB44-3MA0
9 4 22 22 2 2 24 3RT2016-1BB44-3MA0 3RT2016-2BB44-3MA0
12 5.5 22 22 2 2 24 3RT2017-1BB44-3MA0 3RT2017-2BB44-3MA0
16 7.5 22 22 2 2 24 3RT2018-1BB44-3MA0 3RT2018-2BB44-3MA0
With permanently mounted auxiliary switch and integrated coil circuit
(diode integrated at the factory)
7 3 18 22 2 2 24 3RT2015-1FB44-3MA0 3RT2015-2FB44-3MA0
9 4 22 22 2 2 24 3RT2016-1FB44-3MA0 3RT2016-2FB44-3MA0
12 5.5 22 22 2 2 24 3RT2017-1FB44-3MA0 3RT2017-2FB44-3MA0
16 7.5 22 22 2 2 24 3RT2018-1FB44-3MA0 3RT2018-2FB44-3MA0
With voltage tap-off (only available with 24 V DC coils)
7 3 18 10 1 -- 24 3RT2015-1BB41-0CC0 3RT2015-2BB41-0CC0
01 -- 1 24 3RT2015-1BB42-0CC0 3RT2015-2BB42-0CC0
9 4 22 10 1 -- 24 3RT2016-1BB41-0CC0 3RT2016-2BB41-0CC0
01 -- 1 24 3RT2016-1BB42-0CC0 3RT2016-2BB42-0CC0
12 5.5 22 10 1 -- 24 3RT2017-1BB41-0CC0 3RT2017-2BB41-0CC0
01 -- 1 24 3RT2017-1BB42-0CC0 3RT2017-2BB42-0CC0
16 7.5 22 10 1 -- 24 3RT2018-1BB41-0CC0 3RT2018-2BB41-0CC0
01 -- 1 24 3RT2018-1BB42-0CC0 3RT2018-2BB42-0CC0

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/53
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
DC operation for direct control by PLC
• Coupling contactors with adapted power consumption
• Suitable for solid-state PLC/F-PLC outputs
• Cannot be expanded with auxiliary switches
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RT201.-1.B4. 3RT201.-2.B4.
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded
AC-3 and AC-3e, AC-1, supply terminals
tu: 60 °C tu: 40 °C voltage Us
Opera- Ratings of Opera- Ident. Version DC
tional three-phase tional No.
current Ie motors current Ie Article No. Price Article No. Price
up to at 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
(cannot be expanded with auxiliary switches)
Operating range 0.7 ... 1.25 x Us,
power consumption of the solenoid coils 2.8 W at 24 V
7 3 18 10 1 -- 24 3RT2015-1HB41 3RT2015-2HB41
01 -- 1 24 3RT2015-1HB42 3RT2015-2HB42
9 4 22 10 1 -- 24 3RT2016-1HB41 3RT2016-2HB41
01 -- 1 24 3RT2016-1HB42 3RT2016-2HB42
12 5.5 22 10 1 -- 24 3RT2017-1HB41 3RT2017-2HB41
01 -- 1 24 3RT2017-1HB42 3RT2017-2HB42
Operating range 0.85 ... 1.85 x Us,
power consumption of the solenoid coils 1.6 W at 24 V
7 3 18 10 1 -- 24 3RT2015-1MB41-0KT0 3RT2015-2MB41-0KT0
01 -- 1 24 3RT2015-1MB42-0KT0 3RT2015-2MB42-0KT0
9 4 22 10 1 -- 24 3RT2016-1MB41-0KT0 3RT2016-2MB41-0KT0
01 -- 1 24 3RT2016-1MB42-0KT0 3RT2016-2MB42-0KT0
12 5.5 22 10 1 -- 24 3RT2017-1MB41-0KT0 3RT2017-2MB41-0KT0
01 -- 1 24 3RT2017-1MB42-0KT0 3RT2017-2MB42-0KT0
With integrated coil circuit (diode integrated at factory)
(cannot be expanded with auxiliary switches)
Operating range 0.7 ... 1.25 x Us,
power consumption of the solenoid coils 2.8 W at 24 V
7 3 18 10 1 -- 24 3RT2015-1JB41 3RT2015-2JB41
01 -- 1 24 3RT2015-1JB42 3RT2015-2JB42
9 4 22 10 1 -- 24 3RT2016-1JB41 3RT2016-2JB41
01 -- 1 24 3RT2016-1JB42 3RT2016-2JB42
12 5.5 22 10 1 -- 24 3RT2017-1JB41 3RT2017-2JB41
01 -- 1 24 3RT2017-1JB42 3RT2017-2JB42
Operating range 0.85 ... 1.85 x Us,
power consumption of the solenoid coils 1.6 W at 24 V
7 3 18 10 1 -- 24 3RT2015-1VB41 3RT2015-2VB41
01 -- 1 24 3RT2015-1VB42 3RT2015-2VB42
9 4 22 10 1 -- 24 3RT2016-1VB41 3RT2016-2VB41
01 -- 1 24 3RT2016-1VB42 3RT2016-2VB42
12 5.5 22 10 1 -- 24 3RT2017-1VB41 3RT2017-2VB41
01 -- 1 24 3RT2017-1VB42 3RT2017-2VB42

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


3/54 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors, 3-pole up to 250 kW
DC operation for direct control by PLC
• Coupling contactors with adapted power consumption
• Suitable for solid-state PLC/F-PLC outputs
• Cannot be expanded with auxiliary switches
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RT201.-1.B4. 3RT201.-2.B4.
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded terminals
AC-3 and AC-3e, AC-1, supply voltage
tu: 60 °C tu: 40 °C Us
Opera- Ratings of Opera- Ident. Version DC
tional three-phase tional No.
current Ie motors current Ie Article No. Price Article No. Price
up to at 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
With integrated coil circuit (suppressor diode integrated at factory)
(cannot be expanded with auxiliary switches)
Operating range 0.7 ... 1.25 x Us,
power consumption of the solenoid coils 2.8 W at 24 V
7 3 18 10 1 -- 24 3RT2015-1KB41 3RT2015-2KB41
01 -- 1 24 3RT2015-1KB42 3RT2015-2KB42
9 4 22 10 1 -- 24 3RT2016-1KB41 3RT2016-2KB41
01 -- 1 24 3RT2016-1KB42 3RT2016-2KB42
12 5.5 22 10 1 -- 24 3RT2017-1KB41 3RT2017-2KB41
01 -- 1 24 3RT2017-1KB42 3RT2017-2KB42
Operating range 0.85 ... 1.85 x Us,
power consumption of the solenoid coils 1.6 W at 24 V
7 3 18 10 1 -- 24 3RT2015-1SB41 3RT2015-2SB41
01 -- 1 24 3RT2015-1SB42 3RT2015-2SB42
9 4 22 10 1 -- 24 3RT2016-1SB41 3RT2016-2SB41
01 -- 1 24 3RT2016-1SB42 3RT2016-2SB42
12 5.5 22 10 1 -- 24 3RT2017-1SB41 3RT2017-2SB41
01 -- 1 24 3RT2017-1SB42 3RT2017-2SB42

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/55
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RT202.-1B.40 3RT202.-2B.40 3RT202.-1B.44 3RT202.-2B.44


Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded terminals
AC-3 and AC-3e, AC-1, supply voltage
tu: 60 °C tu: 40 °C Us
Opera- Ratings of Opera- Ident. Version DC
tional three-phase tional No.
current Ie motors at current Ie Article No. Price Article No. Price
up to 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S0
9 4 40 11 1 1 24 3RT2023-1BB40 3RT2023-2BB40
12 5.5 40 11 1 1 24 3RT2024-1BB40 3RT2024-2BB40
220 3RT2024-1BM40 3RT2024-2BM40
17 7.5 40 11 1 1 24 3RT2025-1BB40 3RT2025-2BB40
220 3RT2025-1BM40 3RT2025-2BM40
25 11 40 11 1 1 24 3RT2026-1BB40 3RT2026-2BB40
220 3RT2026-1BM40 3RT2026-2BM40
32 15 50 11 1 1 24 3RT2027-1BB40 3RT2027-2BB40
220 3RT2027-1BM40 3RT2027-2BM40
38 18.5 50 11 1 1 24 3RT2028-1BB40 3RT2028-2BB40
220 3RT2028-1BM40 3RT2028-2BM40
With coil circuit plugged into front (varistor plugged in at the factory)
9 4 40 11 1 1 24 3RT2023-1DB40 3RT2023-2DB40
12 5.5 40 11 1 1 24 3RT2024-1DB40 3RT2024-2DB40
17 7.5 40 11 1 1 24 3RT2025-1DB40 3RT2025-2DB40
25 11 40 11 1 1 24 3RT2026-1DB40 3RT2026-2DB40
32 15 50 11 1 1 24 3RT2027-1DB40 3RT2027-2DB40
38 18.5 50 11 1 1 24 3RT2028-1DB40 3RT2028-2DB40
With coil circuit plugged into front (diode assembly plugged in at the factory)
9 4 40 11 1 1 24 3RT2023-1FB40 3RT2023-2FB40
12 5.5 40 11 1 1 24 3RT2024-1FB40 3RT2024-2FB40
17 7.5 40 11 1 1 24 3RT2025-1FB40 3RT2025-2FB40
25 11 40 11 1 1 24 3RT2026-1FB40 3RT2026-2FB40
32 15 50 11 1 1 24 3RT2027-1FB40 3RT2027-2FB40
38 18.5 50 11 1 1 24 3RT2028-1FB40 3RT2028-2FB40
With removable auxiliary switch
9 4 40 22 2 2 24 3RT2023-1BB44 3RT2023-2BB44
12 5.5 40 22 2 2 24 3RT2024-1BB44 3RT2024-2BB44
17 7.5 40 22 2 2 24 3RT2025-1BB44 3RT2025-2BB44
25 11 40 22 2 2 24 3RT2026-1BB44 3RT2026-2BB44
32 15 50 22 2 2 24 3RT2027-1BB44 3RT2027-2BB44
38 18.5 50 22 2 2 24 3RT2028-1BB44 3RT2028-2BB44

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


3/56 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors, 3-pole up to 250 kW
DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RT202.-1.B44-3MA0 3RT202.-2.B44-3MA0 3RT202.-1BB40-0CC0 3RT202.-2BB40-0CC0
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded
AC-3 and AC-3e, AC-1, supply voltage terminals
tu: 60 °C tu: 40 °C Us
Opera- Ratings of Opera- Ident. Version DC
tional three-phase tional No.
current Ie motors at current Ie Article No. Price Article No. Price
up to 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S0
With permanently mounted auxiliary switch and integrated coil circuit
(varistor integrated at the factory)
12 5.5 40 22 2 2 24 3RT2024-1DB44-3MA0 3RT2024-2DB44-3MA0
17 7.5 40 22 2 2 24 3RT2025-1DB44-3MA0 3RT2025-2DB44-3MA0
25 11 40 22 2 2 24 3RT2026-1DB44-3MA0 3RT2026-2DB44-3MA0
32 15 50 22 2 2 24 3RT2027-1DB44-3MA0 3RT2027-2DB44-3MA0
With permanently mounted auxiliary switch and integrated coil circuit
(diode assembly plugged in at the factory)
9 4 40 22 2 2 24 3RT2023-1FB44-3MA0 3RT2023-2FB44-3MA0
12 5.5 40 22 2 2 24 3RT2024-1FB44-3MA0 3RT2024-2FB44-3MA0
17 7.5 40 22 2 2 24 3RT2025-1FB44-3MA0 3RT2025-2FB44-3MA0
25 11 40 22 2 2 24 3RT2026-1FB44-3MA0 3RT2026-2FB44-3MA0
32 15 50 22 2 2 24 3RT2027-1FB44-3MA0 3RT2027-2FB44-3MA0
38 18.5 50 22 2 2 24 3RT2028-1FB44-3MA0 3RT2028-2FB44-3MA0
With voltage tap-off
9 4 40 11 1 1 24 3RT2023-1BB40-0CC0 3RT2023-2BB40-0CC0
12 5.5 40 11 1 1 24 3RT2024-1BB40-0CC0 3RT2024-2BB40-0CC0
17 7.5 40 11 1 1 24 3RT2025-1BB40-0CC0 3RT2025-2BB40-0CC0
25 11 40 11 1 1 24 3RT2026-1BB40-0CC0 3RT2026-2BB40-0CC0
32 15 50 11 1 1 24 3RT2027-1BB40-0CC0 3RT2027-2BB40-0CC0
38 18.5 50 11 1 1 24 3RT2028-1BB40-0CC0 3RT2028-2BB40-0CC0

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/57
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
DC operation for direct control by PLC
• Coupling contactors with adapted power consumption
• Suitable for solid-state PLC/F-PLC outputs
• Cannot be expanded with auxiliary switches
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RT202.-1KB40 3RT202.-2KB40
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded terminals
AC-3 and AC-3e, AC-1, supply voltage
tu: 60 °C tu: 40 °C Us
Opera- Ratings of three- Opera- Ident. Version DC
tional phase motors at tional No.
current Ie 50 Hz and current Ie Article No. Price Article No. Price
up to up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S0
With integrated coil circuit (varistor integrated in electronics at the factory)
(cannot be expanded with auxiliary switches)
Operating range 0.7 ... 1.25 x Us,
power consumption of the solenoid coils 4.5 W at 24 V
9 4 40 11 1 1 24 3RT2023-1KB40 3RT2023-2KB40
12 5.5 40 11 1 1 24 3RT2024-1KB40 3RT2024-2KB40
17 7.5 40 11 1 1 24 3RT2025-1KB40 3RT2025-2KB40
25 11 40 11 1 1 24 3RT2026-1KB40 3RT2026-2KB40
32 15 50 11 1 1 24 3RT2027-1KB40 3RT2027-2KB40

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


3/58 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors, 3-pole up to 250 kW
DC operation for direct control by PLC
• Coupling contactors with adapted power consumption
• Suitable for solid-state PLC/F-PLC outputs with 2 A
• Can be expanded using front or lateral auxiliary switch
(1 x left and 1 x right)
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RT203.-1KB40 3RT203.-3KB40 3RT204.-1KB40 3RT204.-3KB40
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded terminals
AC-3 and AC-3e, AC-1, supply voltage
tu: 60 °C tu: 40 °C Us
Opera- Ratings of three- Opera- Ident. Version DC
tional phase motors at tional No.
current Ie 50 Hz and current Ie Article No. Price Article No. Price
up to up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S2
With integrated coil circuit (varistor integrated in electronics at the factory)
Operating range 0.8 ... 1.2 x Us,
closing power of the solenoid coils 21.5 W at 24 V
41 18.5 60 11 1 1 24 3RT2035-1KB40 3RT2035-3KB40
51 22 70 11 1 1 24 3RT2036-1KB40 3RT2036-3KB40
65 30 80 11 1 1 24 3RT2037-1KB40 3RT2037-3KB40
80 37 90 11 1 1 24 3RT2038-1KB40 3RT2038-3KB40
For screw fixing and snap-on mounting on TH 35-15 and TH 75-15
DIN rails
Size S3
With integrated coil circuit (varistor integrated in electronics at the factory)
Operating range 0.8 ... 1.2 x Us,
closing power of the solenoid coils 25 W at 24 V
80 37 125 11 1 1 24 3RT2045-1KB40 3RT2045-3KB40
95 45 130 11 1 1 24 3RT2046-1KB40 3RT2046-3KB40

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/59
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
AC/DC operation
• Extended operating range of the solenoid coil 0.7 to 1.3 x Us
• Power consumption reduced from closing to closed
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RT202.-1N.30 3RT202.-2N.30
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded terminals
AC-3 and AC-3e, AC-1, supply voltage
tu: 60 °C tu: 40 °C Us
Opera- Ratings of three- Opera- Ident. Version 50/60 Hz AC
tional phase motors at tional No. or DC
current Ie 50 Hz and current Ie Article No. Price Article No. Price
up to up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S0
With integrated coil circuit (varistor integrated in electronics at the factory)
12 5.5 40 11 1 1 21 ... 28 3RT2024-1NB30 3RT2024-2NB30
95 ... 130 3RT2024-1NF30 3RT2024-2NF30
200 ... 280 3RT2024-1NP30 3RT2024-2NP30
17 7.5 40 11 1 1 21 ... 28 3RT2025-1NB30 3RT2025-2NB30
95 ... 130 3RT2025-1NF30 3RT2025-2NF30
200 ... 280 3RT2025-1NP30 3RT2025-2NP30
25 11 40 11 1 1 21 ... 28 3RT2026-1NB30 3RT2026-2NB30
95 ... 130 3RT2026-1NF30 3RT2026-2NF30
200 ... 280 3RT2026-1NP30 3RT2026-2NP30
32 15 50 11 1 1 21 ... 28 3RT2027-1NB30 3RT2027-2NB30
95 ... 130 3RT2027-1NF30 3RT2027-2NF30
200 ... 280 3RT2027-1NP30 3RT2027-2NP30
38 18.5 50 11 1 1 21 ... 28 3RT2028-1NB30 3RT2028-2NB30
95 ... 130 3RT2028-1NF30 3RT2028-2NF30
200 ... 280 3RT2028-1NP30 3RT2028-2NP30

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


3/60 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors, 3-pole up to 250 kW
AC/DC operation
• Extended operating range of the solenoid coil 0.8 to 1.1 x Us
• Power consumption reduced from closing to closed
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RT203.-1N.30 3RT203.-3N.30 3RT203.-1N.34 3RT203.-1NB34-3MA0 3RT203.-3NB34-3MA0
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded terminals
AC-3 and AC-3e, AC-1, supply voltage
tu: 60 °C tu: 40 °C Us
Opera- Ratings of Opera- Ident. Version 50/60 Hz AC
tional three-phase tional No. or DC
current Ie motors at 50 Hz current Ie Article No. Price Article No. Price
up to and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S2
With integrated coil circuit (varistor integrated in electronics at
the factory)
41 18.5 60 11 1 1 20 ... 33 3RT2035-1NB30 3RT2035-3NB30
83 ... 155 3RT2035-1NF30 3RT2035-3NF30
175 ... 280 3RT2035-1NP30 3RT2035-3NP30
51 22 70 11 1 1 20 ... 33 3RT2036-1NB30 3RT2036-3NB30
83 ... 155 3RT2036-1NF30 3RT2036-3NF30
175 ... 280 3RT2036-1NP30 3RT2036-3NP30
65 30 80 11 1 1 20 ... 33 3RT2037-1NB30 3RT2037-3NB30
83 ... 155 3RT2037-1NF30 3RT2037-3NF30
175 ... 280 3RT2037-1NP30 3RT2037-3NP30
80 37 90 11 1 1 20 ... 33 3RT2038-1NB30 3RT2038-3NB30
83 ... 155 3RT2038-1NF30 3RT2038-3NF30
175 ... 280 3RT2038-1NP30 3RT2038-3NP30
With removable auxiliary switch and integrated coil circuit
(varistor integrated in electronics at the factory)
41 18.5 60 22 2 2 20 ... 33 3RT2035-1NB34 --
83 ... 155 3RT2035-1NF34 --
175 ... 280 3RT2035-1NP34 --
51 22 70 22 2 2 20 ... 33 3RT2036-1NB34 --
83 ... 155 3RT2036-1NF34 --
175 ... 280 3RT2036-1NP34 --
65 30 80 22 2 2 20 ... 33 3RT2037-1NB34 --
83 ... 155 3RT2037-1NF34 --
175 ... 280 3RT2037-1NP34 --
80 37 90 22 2 2 20 ... 33 3RT2038-1NB34 --
83 ... 155 3RT2038-1NF34 --
175 ... 280 3RT2038-1NP34 --
With permanently mounted auxiliary switch and integrated coil circuit
(varistor integrated in electronics at the factory)
41 18.5 60 22 2 2 20 ... 33 3RT2035-1NB34-3MA0 3RT2035-3NB34-3MA0
51 22 70 22 2 2 20 ... 33 3RT2036-1NB34-3MA0 3RT2036-3NB34-3MA0
65 30 80 22 2 2 20 ... 33 3RT2037-1NB34-3MA0 3RT2037-3NB34-3MA0
80 37 90 22 2 2 20 ... 33 3RT2038-1NB34-3MA0 3RT2038-3NB34-3MA0
With voltage tap-off and integrated coil circuit (varistor integrated in
electronics at the factory)
41 18.5 60 11 1 1 20 ... 33 3RT2035-1NB30-0CC0 3RT2035-3NB30-0CC0
51 22 70 11 1 1 20 ... 33 3RT2036-1NB30-0CC0 3RT2036-3NB30-0CC0
65 30 80 11 1 1 20 ... 33 3RT2037-1NB30-0CC0 3RT2037-3NB30-0CC0
80 37 90 11 1 1 20 ... 33 3RT2038-1NB30-0CC0 3RT2038-3NB30-0CC0

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.
* You can order this quantity or a multiple thereof.
Illustrations are approximate Siemens IC 10 · 2023 3/61
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
AC/DC operation
• Certified and fail-safe 24 V DC control input with max. 20 mA, For more information, see
e.g. for control via the fail-safe output module of a controller • Safety technology, page 11/1 onwards
(F-PLC) or safety relay • Guide of use for contactors in safety applications
• Achievable Safety Integrity Level (SIL) according to
IEC 62061 and Performance Level (PL) according to
ISO 13849-1 with corresponding fault diagnostics:
- With one contactor: SIL 2/PL c
- With two contactors in series: SIL 3/PL e
3

- Fail-safe applications can be implemented using this


contactor. PU (UNIT, SET, M) = 1
• Extended operating range of the solenoid coil 0.8 to 1.1 x Us PS* = 1 unit
• Power consumption reduced from closing to closed PG = 41B

3RT203.-1S.30 3RT203.-3S.30 3RT204.-1S.30 3RT204.-3S.30


Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded
AC-3 and AC-3e, AC-1, supply voltage terminals
tu: 60 °C tu: 40 °C Us
Opera- Ratings of Opera- Ident. Version 50/60 Hz AC
tional three-phase tional No. or DC
current Ie motors at current Ie Article No. Price Article No. Price
up to 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S2
With integrated coil circuit (varistor integrated in electronics at
the factory)
41 18.5 60 01 -- 1 21 ... 33 3RT2035-1SB30 3RT2035-3SB30
83 ... 150 3RT2035-1SF30 3RT2035-3SF30
175 ... 280 3RT2035-1SP30 3RT2035-3SP30
51 22 70 01 -- 1 21 ... 33 3RT2036-1SB30 3RT2036-3SB30
83 ... 150 3RT2036-1SF30 3RT2036-3SF30
175 ... 280 3RT2036-1SP30 3RT2036-3SP30
65 30 80 01 -- 1 21 ... 33 3RT2037-1SB30 3RT2037-3SB30
83 ... 150 3RT2037-1SF30 3RT2037-3SF30
175 ... 280 3RT2037-1SP30 3RT2037-3SP30
80 37 90 01 -- 1 21 ... 33 3RT2038-1SB30 3RT2038-3SB30
83 ... 150 3RT2038-1SF30 3RT2038-3SF30
175 ... 280 3RT2038-1SP30 3RT2038-3SP30
For screw fixing and snap-on mounting on TH 35-15 and
TH 75-15 DIN rails
Size S3
With integrated coil circuit (varistor integrated in electronics at
the factory)
80 37 125 01 -- 1 21 ... 33 3RT2045-1SB30 3RT2045-3SB30
83 ... 150 3RT2045-1SF30 3RT2045-3SF30
175 ... 280 3RT2045-1SP30 3RT2045-3SP30
95 45 130 01 -- 1 21 ... 33 3RT2046-1SB30 3RT2046-3SB30
83 ... 150 3RT2046-1SF30 3RT2046-3SF30
175 ... 280 3RT2046-1SP30 3RT2046-3SP30
110 55 130 01 -- 1 21 ... 33 3RT2047-1SB30 3RT2047-3SB30
83 ... 150 3RT2047-1SF30 3RT2047-3SF30
175 ... 280 3RT2047-1SP30 3RT2047-3SP30

Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


3/62 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors, 3-pole up to 250 kW
AC/DC operation
• Extended operating range of the solenoid coil 0.8 to 1.1 x Us
• Power consumption reduced from closing to closed
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RT204.-1N.30 3RT204.-3N.30 3RT204.-1N.34 3RT204.-1NB34-3MA0 3RT204.-3NB34-3MA0
Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded
AC-3 and AC-3e, AC-1, supply voltage terminals
tu: 60 °C tu: 40 °C Us
Opera- Ratings of Opera- Ident. Version 50/60 Hz AC
tional three-phase tional No. or DC
current Ie motors at current Ie Article No. Price Article No. Price
up to 50 Hz and up to per PU per PU
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35-15 and
TH 75-15 DIN rails
Size S3
With integrated coil circuit (varistor integrated in electronics at
the factory)
80 37 125 11 1 1 20 ... 33 3RT2045-1NB30 3RT2045-3NB30
83 ... 155 3RT2045-1NF30 3RT2045-3NF30
175 ... 280 3RT2045-1NP30 3RT2045-3NP30
95 45 130 11 1 1 20 ... 33 3RT2046-1NB30 3RT2046-3NB30
83 ... 155 3RT2046-1NF30 3RT2046-3NF30
175 ... 280 3RT2046-1NP30 3RT2046-3NP30
110 55 130 11 1 1 20 ... 33 3RT2047-1NB30 3RT2047-3NB30
83 ... 155 3RT2047-1NF30 3RT2047-3NF30
175 ... 280 3RT2047-1NP30 3RT2047-3NP30
With removable auxiliary switch and integrated coil circuit
(varistor integrated in electronics at the factory)
80 37 125 22 2 2 20 ... 33 3RT2045-1NB34 --
83 ... 155 3RT2045-1NF34 --
175 ... 280 3RT2045-1NP34 --
95 45 130 22 2 2 20 ... 33 3RT2046-1NB34 --
83 ... 155 3RT2046-1NF34 --
175 ... 280 3RT2046-1NP34 --
110 55 130 22 2 2 20 ... 33 3RT2047-1NB34 --
83 ... 155 3RT2047-1NF34 --
175 ... 280 3RT2047-1NP34 --
With permanently mounted auxiliary switch and integrated coil circuit
(varistor integrated in electronics at the factory)
80 37 125 22 2 2 20 ... 33 3RT2045-1NB34-3MA0 3RT2045-3NB34-3MA0
95 45 130 22 2 2 20 ... 33 3RT2046-1NB34-3MA0 3RT2046-3NB34-3MA0
110 55 130 22 2 2 20 ... 33 3RT2047-1NB34-3MA0 3RT2047-3NB34-3MA0
With voltage tap-off and integrated coil circuit (varistor integrated in
electronics at the factory)
80 37 125 11 1 1 20 ... 33 3RT2045-1NB30-0CC0 3RT2045-3NB30-0CC0
95 45 130 11 1 1 20 ... 33 3RT2046-1NB30-0CC0 3RT2046-3NB30-0CC0
110 55 130 11 1 1 20 ... 33 3RT2047-1NB30-0CC0 3RT2047-3NB30-0CC0

Other voltages according to page 3/67 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/63
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
AC/DC operation
• Standard operating mechanism 3RT10..-.A
• For screw fixing
• Auxiliary and control conductors: Screw terminals
or spring-loaded terminals
• Main conductors: Busbar connections;
a connection kit with screws, spring washers and nuts
is enclosed.
PU (UNIT, SET, M) = 1
3

PS* = 1 unit
PG = 41B

3RT105.-6A.36 3RT106.-6A.36 3RT107.-6A.36 3RT107.-2A.36


Size Rated data Auxiliary Rated control Screw terminals Spring-loaded terminals
AC-3 and AC-3e, AC-1, contacts, supply
tu: 60 °C tu: 40 °C lateral voltage Us
Opera- Rating of Opera- Version 50/60 Hz AC
tional three-phase motors tional or DC
current Ie at 50 Hz and current Ie Article No. Price Article No. Price
up to up to per PU per PU

500 V 400 V 500 V 690 V 690 V


A kW kW kW A NO NC V
Standard operating mechanism for AC and DC operation
(power consumption reduced from closing to closed)
With integrated coil circuit (varistor integrated at the factory)
S6 115 55 75 110 160 2 2 110 ... 127 3RT1054-6AF36 3RT1054-2AF36
220 ... 240 3RT1054-6AP36 3RT1054-2AP36
150 75 90 132 185 2 2 110 ... 127 3RT1055-6AF36 3RT1055-2AF36
220 ... 240 3RT1055-6AP36 3RT1055-2AP36
185 90 132 160 215 2 2 110 ... 127 3RT1056-6AF36 3RT1056-2AF36
220 ... 240 3RT1056-6AP36 3RT1056-2AP36
S10 225 110 160 On request 275 2 2 110 ... 127 3RT1064-6AF36 3RT1064-2AF36
220 ... 240 3RT1064-6AP36 3RT1064-2AP36
265 132 160 On request 330 2 2 110 ... 127 3RT1065-6AF36 3RT1065-2AF36
220 ... 240 3RT1065-6AP36 3RT1065-2AP36
300 160 200 On request 330 2 2 110 ... 127 3RT1066-6AF36 3RT1066-2AF36
220 ... 240 3RT1066-6AP36 3RT1066-2AP36
S12 400 200 250 400 430 2 2 110 ... 127 3RT1075-6AF36 3RT1075-2AF36
220 ... 240 3RT1075-6AP36 3RT1075-2AP36
500 250 315 400 610 2 2 110 ... 127 3RT1076-6AF36 3RT1076-2AF36
220 ... 240 3RT1076-6AP36 3RT1076-2AP36

Other voltages according to page 3/68 on request.


Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


3/64 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors, 3-pole up to 250 kW
AC/DC operation
• Certified and fail-safe 24 V DC control input with max. 20 mA, • For screw fixing
e.g. for control via the fail-safe output module of a controller • Auxiliary and control conductors: Screw terminals
(F-PLC) or safety relay • Main conductors: Busbar connections;
• Achievable Safety Integrity Level (SIL) according to a connection kit with screws, spring washers and nuts
IEC 62061 and Performance Level (PL) according to is enclosed.
ISO 13849-1 with corresponding fault diagnostics:
- With one contactor: SIL 2/PL c For more information, see
- With two contactors in series: SIL 3/PL e • Safety technology, page 11/1 onwards

3
- Fail-safe applications can be implemented using • Guide of use for contactors in safety applications
this contactor.
• Version with removable lateral auxiliary switches or
permanently mounted auxiliary switches

3RT105.-6S.36 3RT106.-6S.36 3RT107.-6S.36 3RT105.-6S.36-3PA0 3RT107.-6S.36-3PA0

Size Rated data according to IEC 60947-4-1 Auxiliary Rated control Screw terminals PU PS* PG
AC-3 and AC-3e, contacts, supply voltage (UNIT,
tu: 60 °C lateral Us SET, M)
Operational Rating of three-phase Version 50/60 Hz AC
current Ie motors at 50 Hz and or DC
up to Article No. Price
per PU
500 V 400 V
A kW NO NC V
Solid-state operating mechanism
With two removable laterally mounted auxiliary switches
With integrated coil circuit (varistor integrated in electronics at the factory)
S6 115 55 2 2 96 ... 127 3RT1054-6SF36 1 1 unit 41B
200 ... 277 3RT1054-6SP36 1 1 unit 41B
150 75 2 2 96 ... 127 3RT1055-6SF36 1 1 unit 41B
200 ... 277 3RT1055-6SP36 1 1 unit 41B
185 90 2 2 96 ... 127 3RT1056-6SF36 1 1 unit 41B
200 ... 277 3RT1056-6SP36 1 1 unit 41B
S10 225 110 2 2 96 ... 127 3RT1064-6SF36 1 1 unit 41B
200 ... 277 3RT1064-6SP36 1 1 unit 41B
265 132 2 2 96 ... 127 3RT1065-6SF36 1 1 unit 41B
200 ... 277 3RT1065-6SP36 1 1 unit 41B
300 160 2 2 96 ... 127 3RT1066-6SF36 1 1 unit 41B
200 ... 277 3RT1066-6SP36 1 1 unit 41B
S12 400 200 2 2 96 ... 127 3RT1075-6SF36 1 1 unit 41B
200 ... 277 3RT1075-6SP36 1 1 unit 41B
500 250 2 2 96 ... 127 3RT1076-6SF36 1 1 unit 41B
200 ... 277 3RT1076-6SP36 1 1 unit 41B
With two permanently laterally mounted auxiliary switches
With integrated coil circuit (varistor integrated in electronics at the factory)
S6 115 55 2 2 96 ... 127 3RT1054-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1054-6SP36-3PA0 1 1 unit 41B
150 75 2 2 96 ... 127 3RT1055-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1055-6SP36-3PA0 1 1 unit 41B
185 90 2 2 96 ... 127 3RT1056-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1056-6SP36-3PA0 1 1 unit 41B
S10 225 110 2 2 96 ... 127 3RT1064-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1064-6SP36-3PA0 1 1 unit 41B
265 132 2 2 96 ... 127 3RT1065-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1065-6SP36-3PA0 1 1 unit 41B
300 160 2 2 96 ... 127 3RT1066-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1066-6SP36-3PA0 1 1 unit 41B
S12 400 200 2 2 96 ... 127 3RT1075-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1075-6SP36-3PA0 1 1 unit 41B
500 250 2 2 96 ... 127 3RT1076-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1076-6SP36-3PA0 1 1 unit 41B

Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/65
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
AC/DC operation
• Solid-state operating mechanism • For screw fixing
- 3RT10..-.N with 24 V DC control signal input • Auxiliary and control conductors: Screw terminals or
- 3RT10..-.P with 24 V DC control signal input and with spring-loaded terminals
remaining lifetime indicator (RLT) • Main conductors: Busbar connections;
a connection kit with screws, spring washers and nuts
is enclosed.
PU (UNIT, SET, M) = 1
PS* = 1 unit
3

PG = 41B

3RT105.-6N.36 3RT106.-2N.36 3RT107.-6N.36 3RT107.-6P.35 3RT107.-2N.36


Size Rated data Auxiliary Rated control Screw terminals Spring-loaded terminals
AC-3 and AC-3e, AC-1, contacts, supply
tu: 60 °C tu: 40 °C lateral voltage Us
Opera- Rating of Opera- Version 50/60 Hz AC
tional three-phase motors tional or DC
current Ie at 50 Hz and current Ie Article No. Price Article No. Price
up to up to per PU per PU

500 V 400 V 500 V 690 V 690 V


A kW kW kW A NO NC V
Solid-state operating mechanism
With 24 V DC control signal input
e.g. for control by PLC
With integrated coil circuit (varistor integrated in electronics at the factory)
S6 115 55 75 110 160 2 2 96 ... 127 3RT1054-6NF36 3RT1054-2NF36
200 ... 277 3RT1054-6NP36 3RT1054-2NP36
150 75 90 132 185 2 2 96 ... 127 3RT1055-6NF36 3RT1055-2NF36
200 ... 277 3RT1055-6NP36 3RT1055-2NP36
185 90 132 160 215 2 2 96 ... 127 3RT1056-6NF36 3RT1056-2NF36
200 ... 277 3RT1056-6NP36 3RT1056-2NP36
S10 225 110 160 On request 275 2 2 96 ... 127 3RT1064-6NF36 3RT1064-2NF36
200 ... 277 3RT1064-6NP36 3RT1064-2NP36
265 132 160 On request 330 2 2 96 ... 127 3RT1065-6NF36 3RT1065-2NF36
200 ... 277 3RT1065-6NP36 3RT1065-2NP36
300 160 200 On request 330 2 2 96 ... 127 3RT1066-6NF36 3RT1066-2NF36
200 ... 277 3RT1066-6NP36 3RT1066-2NP36
S12 400 200 250 400 430 2 2 96 ... 127 3RT1075-6NF36 3RT1075-2NF36
200 ... 277 3RT1075-6NP36 3RT1075-2NP36
500 250 315 400 610 2 2 96 ... 127 3RT1076-6NF36 3RT1076-2NF36
200 ... 277 3RT1076-6NP36 3RT1076-2NP36
With 24 V DC control signal input · With remaining lifetime indicator (RLT),
e.g. for control by PLC
With integrated coil circuit (varistor integrated in electronics at the factory)
S6 115 55 75 110 160 1 1 96 ... 127 3RT1054-6PF35 --
200 ... 277 3RT1054-6PP35 --
150 75 90 132 185 1 1 96 ... 127 3RT1055-6PF35 --
200 ... 277 3RT1055-6PP35 --
185 90 132 160 215 1 1 96 ... 127 3RT1056-6PF35 --
200 ... 277 3RT1056-6PP35 --
S10 225 110 160 On request 275 1 1 96 ... 127 3RT1064-6PF35 --
200 ... 277 3RT1064-6PP35 --
265 132 160 On request 330 1 1 96 ... 127 3RT1065-6PF35 --
200 ... 277 3RT1065-6PP35 --
300 160 200 On request 330 1 1 96 ... 127 3RT1066-6PF35 --
200 ... 277 3RT1066-6PP35 --
S12 400 200 250 400 430 1 1 96 ... 127 3RT1075-6PF35 --
200 ... 277 3RT1075-6PP35 --
500 250 315 400 610 1 1 96 ... 127 3RT1076-6PF35 --
200 ... 277 3RT1076-6PP35 --

Other voltages according to page 3/68 on request. Accessories and spare parts, see pages 3/69 to 3/119.

* You can order this quantity or a multiple thereof.


3/66 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW

■ Options
Rated control supply voltages for 3RT20 contactors,
possible on request (change of the 10th and 11th digits of the article number)
Delivery time on request
Rated control supply Contactor type 3RT201, 3RH2 3RT202 3RT203 3RT204
voltage Us Size S00 S0 S2 S3
Sizes S00 to S3

3
AC operation1)
Solenoid coils for 50 Hz
(exception: Size S00: 50 and 60 Hz2))
24 V AC B0 B0 B0 B0
42 V AC D0 D0 D0 D0
48 V AC H0 H0 H0 H0
110 V AC F0 F0 F0 F0
230 V AC P0 P0 P0 P0
240 V AC U0 U0 U0 U0
400 V AC V0 V0 V0 V0
Solenoid coils for 50 and 60 Hz2)
24 V AC B0 C2 C2 C2
42 V AC D0 D2 D2 D2
48 V AC H0 H2 H2 H2
110 V AC F0 G2 G2 G2
220 V AC N2 N2 N2 N2
230 V AC P0 L2 L2 L2
Solenoid coils (for USA and Canada3))
50 Hz 60 Hz
110 V AC 120 V AC K6 K6 K6 K6
220 V AC 240 V AC P6 P6 P6 P6
Solenoid coils (for Japan)
50/60 Hz4) 60 Hz5)
100 V AC 110 V AC G6 G6 G6 G6
200 V AC 220 V AC N6 N6 N6 N6
400 V AC 440 V AC R6 R6 R6 R6
DC operation1)
12 V DC A4 A4 -- --
24 V DC B4 B4 -- --
42 V DC D4 D4 -- --
48 V DC W4 W4 -- --
60 V DC E4 E4 -- --
110 V DC F4 F4 -- --
125 V DC G4 G4 -- --
220 V DC M4 M4 -- --
230 V DC P4 P4 -- --
Examples
AC operation 3RT2023-1AP00 Contactor with screw terminals; with solenoid coil for 50 Hz for rated control supply voltage 230 V AC.
3RT2023-1AG20 Contactor with screw terminals; with solenoid coil for 50/60 Hz for rated control supply voltage 110 V AC.
DC operation 3RT2025-2BB40 Contactor with spring-loaded terminals; for rated control supply voltage 24 V DC.
3RT2025-2BG40 Contactor with spring-loaded terminals; for rated control supply voltage 125 V DC.
1) 4)
For deviating coil voltages and operating ranges of sizes S00 and S0, Coil operating range
a SITOP 24 V DC power supply with wide-range input can be used for - Size S00:
the coil control, see page 15/1 and Catalog KT 10.1. at 50/60 Hz: 0.85 to 1.1 x Us,
2)
Coil operating range - Size S0:
- at 50 Hz: 0.8 to 1.1 x Us, at 50 Hz: 0.8 to 1.1 x Us,
- at 60 Hz: 0.85 to 1.1 x Us. at 60 Hz: 0.85 to 1.1 x Us.
3) 5) Coil operating range at 60 Hz: 0.8 to 1.1 x U .
Coil operating range s
- Size S00:
at 50 Hz: 0.85 to 1.1 x Us,
at 60 Hz: 0.8 to 1.1 x Us,
- Sizes S0 to S3: at 50 Hz and 60 Hz: 0.8 to 1.1 x Us.

Rated control supply voltage Contactor type 3RT202.-.N Rated control supply voltage Contactor type 3RT203.-.N 3RT204.-.N
Us min to Us max1) Size S0 Us min to Us max1) Size S2 S3
Sizes S00 to S3
AC/DC operation (50/60 Hz AC or DC)
21 ... 28 V AC/DC B3 20 ... 33 V AC/DC B3 B3
95 ... 130 V AC/DC F3 48 ... 80 V AC/DC E3 E3
200 ... 280 V AC/DC2) P3 83 ... 155 V AC/DC F3 F3
175 ... 280 V AC/DC P3 P3
1) 2)
Coil operating range The following applies to S0 and Us max = 280 V: Upper limit = 1.1 x Us max
- Size S0: 0.7 x Us min to 1.3 x Us max,
- Sizes S2 and S3: 0.8 x Us min to 1.1 x Us max.

Siemens IC 10 · 2023 3/67


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT contactors, 3-pole up to 250 kW
Rated control supply voltages for 3RT10 contactors,
possible on request (change of the 10th and 11th digits of the article number)
Delivery time on request
Rated control supply Contactor 3RT105.-.A, Rated control supply Contactor 3RT105.-.N, 3RT105.-.P,
voltage type 3RT106.-.A, voltage type 3RT106.-.N, 3RT105.-.S,
3RT107.-.A 3RT107.-.N 3RT106.-.P,
3RT106.-.S,
3RT107.-.P,
3RT107.-.S
3

Us min to Us max Sizes S6 to S12 Us min to Us max Sizes S6 to S12


Sizes S6 to S12
AC/DC operation (50/60 Hz AC or DC) and operating range 0.8 x Us min to 1.1 x Us max
Standard operating mechanism Solid-state operating mechanism
23 ... 26 V AC/DC B3 21 ... 27.3 V AC/DC B3 --
42 ... 48 V AC/DC D3 96 ... 127 V AC/DC F3 F3
110 ... 127 V AC/DC F3 200 ... 277 V AC/DC P3 P3
200 ... 220 V AC/DC M3
220 ... 240 V AC/DC P3
240 ... 277 V AC/DC U3
380 ... 420 V AC/DC V3
440 ... 480 V AC/DC R3
500 ... 550 V AC/DC S3
575 ... 600 V AC/DC T3

3/68 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data

■ Overview
Extensive accessories and spare parts are available for
SIRIUS 3RT power contactors and SIRIUS 3RH2 contactor relays. More information

These components are easily fitted to the contactors without TIA Selection Tool Cloud (TST Cloud), see
www.siemens.com/tstcloud/?node=Contactor
the use of any tools according to requirements.
Overview graphics with mountable accessories:
• 3RT2 contactors, see pages 3/8 to 3/11

3
• 3RT10, 3RT12 and 3RT14 contactors, see pages 3/12 to 3/16
• 3RH2 contactor relays, see page 5/5

Version For contactors Selection and


3RT2, 3RT105 to 3RT107, ordering data
sizes S00 to S3; 3RT126 and 3RT127,
3RH2, 3RT145 to 3RT147;
size S00 sizes S6 to S12 Page
Accessories for 3RT contactors and 3RH2 contactor relays
Auxiliary switches
Instantaneous 3RH29.1 3RH19.1 3/81 ... 3/94
Delayed
• Pneumatic time-delay auxiliary switches 3RT2927-2P..1 -- 3/95
• Solid-state time-delay auxiliary switches 3RA2813, 3RA2814, 3RA2815 3RT1926-2E/-2F/-2G 3/95, 3/96
Surge suppressors
• Without LED 3RT29.6-1B/-1C/-1D/-1E 3RT1956-1C 3/97, 3/98
• With LED 3RT29.6-1J/-1L/-1M -- 3/98
Modules for contactor control
Coupling links for control by PLC 3RH29.4-.GP11 -- 3/99
3RA28 function modules
• For direct on-line starting: ON delay or OFF-delay 3RA2811, 3RA2812, -- 3/100
3RA2831, 3RA2832
• For star-delta (wye-delta) starting 3RA2816 -- 3/100
3RA27 function modules for IO-Link or AS-Interface
• For direct-on-line, reversing or star-delta (wye-delta) starting 3RA271.-.A/-.B/-.C -- 3/101, 3/102
Mechanical latching blocks 3RT2926-3A.31 -- 3/103
OFF-delay devices for contactors with AC/DC and DC operation 3RT2916-2B.01 -- 3/103
Link modules
Link modules from motor starter protector to contactor 3RA.9.1 -- 7/61
Safety main current connectors for two contactors 3RA29.6-1A -- 3/104
Assembly kits
• For reversing contactor assemblies 3RA29.3-2AA. 3RA19.3-2A 3/104
• For contactor assemblies for star-delta (wye-delta) starting 3RA29..-2BB., 3RA29.3-2C 3RA1953-3G, 3RA19.3-2./-3. 3/105, 3/106
Single wiring modules 3RA.9.3-3.A. 3RA19.3-3. 3/107
Star jumpers (links for paralleling), 3-pole 3RT.9.6-4BA3. 3RT19.6-4BA31 3/107
Mechanical interlock kits for two contactors 3RA29.2-2H -- 3/108
Mechanical interlocks for contactor assemblies 3RA2934-2B 3RA1954-2. 3/108
Mechanical connectors for contactor assemblies 3RA29.2-2. 3RA1932-2D 3/108
Connection modules/adapters
Links for paralleling for main conducting paths 3RT.9.6-4BB.1 -- 3/109
1-phase infeed terminals 3RA2943-3L -- 3/110
3-phase infeed terminals 3RA2913-3K, 3RV29.5-5A. -- 3/110
• With increased clearance and creepage distances 3RV2935-5E -- 3/110
3-phase busbars 3RV1915-1AB -- 3/110
Terminal blocks for connecting auxiliary conductors to main terminals
• Box terminal blocks 3RT2946-4G 3RT19..-4G 3/110
• Box terminal for auxiliary conductor connection, 1-pole -- 3TX7500-0A 3/110
• Auxiliary conductor terminals, 3-pole 3RT2946-4F -- 3/110
Solder pin adapters for mounting contactors on printed circuit boards 3RT1916-4KA. -- 3/111
Coil connection modules for connections from top or from bottom 3RT2926-4R.1. -- 3/111
Connection module (adapter and plug) for contactors with screw
terminals
• Adapters 3RT19.6-4RD01 -- 3/111
• Motor feeder connector 3RT1900-4RE01 -- 3/111

Siemens IC 10 · 2023 3/69


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data

Version For contactors Selection and


3RT2, 3RT105 to 3RT107, ordering data
sizes S00 to S3; 3RT126 and 3RT127,
3RH2, 3RT145 to 3RT147;
size S00 sizes S6 to S12 Page
Accessories for 3RT contactors and 3RH2 contactor relays (continued)
Covers
Terminal covers 3RT1946-4EA1, 3RT29.6-4EA. 3RT1956-4EA., 3RT1966-4EA., 3/112
3TX65.6-3B
3

Sealable covers 3RT2916-4MA10 3RT1926-4MA10 3/112


Miscellaneous accessories
Base plates
• For reversing contactor assemblies -- 3RT19.2-2A 3/113
• For contactor assemblies for star-delta (wye-delta) starting 3RA29.2-2F 3RA19.2-2. 3/113
Adapters for screw fixing 3RT1926-4P -- 3/113
Connection kit for one complete contactor -- 3RT19..-4PA00 3/113
EMC suppression modules 3RT2916-1P . . -- 3/113
Additional load modules 3RT2916-1GA00 -- 3/114
LED modules for displaying contactor operation 3RT2926-1QT00 3RT1926-1QT00 3/114
Control kit 3RT29.6-4MC00 -- 3/114
Insulation stop for securely holding back the conductor insulation for 3RT2916-4JA02 3RT1916-4JA02 3/115
conductors up to 1 mm2
Tools for opening spring-loaded terminals 3RA2908-1A 3RA2908-1A 3/115
Blank labels 3RT2900-1SB.0 3RT2900-1SB.0 3/115
Spare parts for 3RT2 contactors
Solenoid coils 3RT29..-5...1 -- 3/116, 3/117
Withdrawable coils -- 3RT19..-5.... 3/118
Contacts with fixing parts 3RT29..-6. 3RT19..-6. 3/119
Arc chutes -- 3RT19..-7. 3/119

3/70 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data
Auxiliary switches Surge suppressors
The auxiliary switches can be designed as force-guided • Without LED (also for spring-loaded terminals)
contacts in 3RH contactor relays or also as mirror contacts in the Sizes S00 to S3, see page 3/97
case of 3RT power contactors. • With LED (also for spring-loaded terminals)
For more information on force-guided operation and mirror Sizes S00 to S3, see page 3/98
contacts, see Manuals "More information", page 3/76, and in All 3RT2 contactors and 3RH2 contactor relays can be retrofitted
the selection and ordering data, page 3/81 onwards. with RC elements or varistors for damping switching
overvoltages in the coil. Diodes or diode assemblies
Solid-state time-delay auxiliary switches for mounting on

3
(combination of interference suppression diode and Zener
3RT2 contactors and 3RH2 contactor relays diode for short break times) can also be used.
See pages 3/76 and 3/95 The surge suppressors are plugged onto the front of size S00
The 3RA28 solid-state time-delayed auxiliary switches which contactors. Space is provided for them next to a snap-on
can be mounted on the contactor are designed for applications auxiliary switch.
in the range from 24 to 240 V AC/DC (wide voltage range). Both Varistors, RC elements or diode assemblies can be plugged
the electrical and mechanical connection are made by simple onto the front of size S0 to S3 contactors. Exception: For size S3,
snapping on and locking. the RC element is inserted on the front into the recesses to the
The time-delay auxiliary switch is supplied with power directly by left of the connection block.
two plug-in contacts through the coil terminals of the contactor, Coupling contactors are supplied either without overvoltage
in parallel with A./A2. damping or with a suppressor diode, varistor or diode
A protection circuit (varistor) is integrated in each module. connected as standard, according to the version.
A sealable cover is available to protect against careless Note:
adjustment of the set times. The break times of the contactor, the opening delay times of the
Note: NO contacts and the closing delay times of the NC contacts
increase with damping.
Mounting more auxiliary switches on the contactor is not
permitted. For more detailed information about how damping affects the
time response, see Equipment Manual.
Coupling links for control by PLC
See pages 3/78 and 3/99
• Operation with 24 V DC
• Operating range 17 to 30 V
• Low power consumption of 0.5 W
• An LED indicates the switching state.
The 3RH2924-1GP11 coupling link has an integrated surge
suppressor (varistor) for the contactor coil being switched and
is mounted on the size S0 contactor coil via a coil connection
module.

Siemens IC 10 · 2023 3/71


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data
3RA28 function modules for mounting on 3RT2 contactors Assembly of reversing starters
and 3RH2 contactor relays
We offer ready-made wiring kits for the assembly of reversing
See pages 3/79 and 3/100 starters. Use of these wiring kits offers further advantages,
see page 3/148.
Simply by being plugged in place, the SIRIUS function modules
enable different functionalities required for the assembly of SIRIUS function modules for star-delta (wye-delta) starting
starters to be realized in the feeder. The function modules and
wiring kits thus help to reduce the wiring work within the feeder Both interlocking and timing functions are required for the
practically to zero. assembly of star-delta (wye-delta) starters. With the function
modules for star-delta (wye-delta) starting and the matching link
3

Protection of the device connections modules for the main circuit, these starters can be assembled
easily and with absolutely no errors.
The specifications for short-circuit protection (fuses, circuit
breakers, or miniature circuit breakers) are available for the The entire sequence in the control circuit is integrated in the
device connections of the main circuit and the auxiliary circuit. snap-on modules. This covers:
In order to ensure a holistic view for the protection of the device • An adjustable star time t from 0.5 to 60 s
connections, the manufacturer is obliged to provide all relevant • A non-adjustable dead interval of 50 ms
information for short-circuit protection and overcurrent • Electrical contacting of the contactors by means of coil
protection. pick-off (contact legs)
• Feedback of the switching state at the contactor using
For more information, for example if device connections for a mechanical switch position indicator (plunger)
the control supply voltage, the supply voltage, or digital • Electrical interlocking between the contactors
inputs/digital outputs are not connected to self-limiting current
sources or energy sources, see Equipment Manual or the These modules do not require their own terminals and can
technical product data sheet. therefore be used for contactors with both screw and spring-
loaded terminals in all the sizes S00 to S3. To start the star-delta
SIRIUS function modules for direct-on-line starting (wye-delta) starter, only the first of the three contactors (line
The electronic timing relays which can be mounted on the contactor) is actuated, like in the case of a direct-on-line starter.
contactor are available in these versions: All other functions then take place inside the individual modules.
• Sizes S00 and S0 for applications in the range from 24 to This also offers advantages if the timing function was previously
240 V AC/DC (wide voltage range) implemented in a controller, as it again results in a significant
• Sizes S2 and S3 for applications in either the range from reduction in the number of PLC outputs, the programming work
24 to 90 V AC/DC or 90 to 240 V AC/DC and the wiring outlay.
Both the electrical and mechanical connection are made The kits for the main circuit include the mechanical interlock,
by simple snapping on and locking. the star jumper, the wiring modules at the top and at the bottom,
and the required connectors or connecting clips.
A protection circuit (varistor) is integrated in each module.
A protection circuit (varistor) is integrated in the basic module.
The electronic timing relay with semiconductor output uses two
contact legs to actuate the contactor underneath by means of The function modules for star-delta (wye-delta) starting are
a semiconductor after the set time t has elapsed. mostly used where current-limiting measures for starting a drive
are required and a high level of availability is essential at the
The switching state feedback is performed by a mechanical same time. This technology has been used with success for
switching state indicator (plunger). In addition, the auxiliary several decades and has the additional advantage of requiring
switches in the contactors are freely accessible and can be used relatively little know-how. Through the use of function modules,
for feedbacks to the control system or for signal lamps. the assembly work with simple standard components is even
A sealable cover is available to protect against careless easier and absolutely error-free.
adjustment of the set times. The use of function modules for star-delta (wye-delta) starting
The snap-on function modules for direct-on-line starting are results in the following advantages:
used above all for realizing timing functions independently of • Operation solely through the line contactor A1/A2 – no further
the control system. control current wiring needed
With the OFF-delay variant of the timing relay it is possible for • Prevention of wiring errors
example for the fan motor for cooling a main drive to be switched • Reduction of testing costs
off with a delay so that sufficient cooling after operation is • Integrated electrical interlocking saves costs and prevents
guaranteed; the programmer of the control system does not errors
need to worry about such technical details of the plant. • Less space needed in the control cabinet compared to using
a separate timing relay
The ON-delay timing relays enable for example the time-delayed • Adjustable starting in star mode from 0.5 to 60 s
starting of several drives so that the summation starting current • Independent of the contactor's control supply voltage
does not rise too high, which could result in voltage failure. (24 to 240 V AC/DC)
• Varistor integrated – no additive protection circuit required
The use of snap-on function modules for direct-on-line starting • Mechanically coded assembly enables easy configuration
results in the following advantages: and reliable wiring
• Reduction of control current wiring • Fewer versions – one module kit for screw and spring-loaded
• Prevention of wiring errors connection and for all the contactor sizes S00 to S3
• Reduction of testing costs • Mechanical interlocking (with wiring kit for the main circuit)
• Implementation of timing functions independently of the
control system
• Less space required in the control cabinet compared to
a separate timing relay
• No additive protection circuit required (varistor integrated)

3/72 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data
SIRIUS 3RA27 function modules for IO-Link or AS-Interface The starters are connected to the higher-level control system
for mounting on 3RT2 contactors through IO-Link, with the possibility of connecting up to four
starters as a group to one port of the IO-Link master,
See pages 3/80 and 3/101
Optionally, the connection can be made via AS-Interface
The SIRIUS 3RA27 function modules enable the assembly of (specification V2.1 or higher, in A/B technology). As a result,
starters and contactor assemblies for direct-on-line, reversing up to 62 starters can be connected to one master and the
and star-delta (wye-delta) starting without any additional, address is entered in the normal manner with an addressing unit.
complicated wiring of the individual components. They include
the key control functions, e.g. timing and interlocking, required Through this type of connection to the control system, a maxi-
for the particular feeder and can be connected to the control mum of wiring is saved. In the case of AS-Interface, the wiring

3
system via either IO-Link or AS-Interface. amounts to the control supply voltage and the two individual
wires for AS-Interface.
The electrical and mechanical connection to the contactor
is established by snapping on and locking the respective The following essential signals are thus transmitted:
modules. An additive protection circuit for the individual • Availability of the feeder in response to an indirect inquiry from
contactors can be dispensed with completely because a varistor the motor starter protector/circuit breaker
is integrated in the modules. Feedback from the contactor
contacts is performed with Hall sensors which provide reliable • Starter control
feedback on the switching state even under extremely dusty • Feedback concerning the switching state of the starter
conditions.

Availability

Control

PLC Feedback on switching state PLC IO-Link

NSB0_02084a

Signal transmission through IO-Link

Availability

Control

PLC Feedback on switching state PLC AS-Interface

NSB0_02085a

Signal transmission through AS-Interface

Siemens IC 10 · 2023 3/73


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data
The inquiry from the motor starter protector/circuit breaker does not This requires special versions of the 3RT20..-.....-0CC0 contactors
take place through additive wiring between the auxiliary switch and with voltage tap-off (see pages 3/53, 3/57, 3/61 and 3/63).
the module but by means of a voltage inquiry at the contactor input.

Motor starter protector


3

Contactor

NSB0_02086
Availability signal through voltage tap-off
The following benefits result from the use of SIRIUS 3RA27 Protection of the device connections
function modules:
The specifications for short-circuit protection (fuses, circuit
• Reduction of control current wiring. In the case of IO-Link to no breakers, or miniature circuit breakers) are available for the
more than three cables for four feeders. device connections of the main circuit and the auxiliary circuit.
• Elimination of testing costs and wiring errors In order to ensure a holistic view for the protection of the device
• Reduction of configuration work connections, the manufacturer is obliged to provide all relevant
• Parameter server functionality information for short-circuit protection and overcurrent protection.
• Integration in TIA means unambiguous IO-Link diagnostics For more information, for example if device connections for the
if a fault occurs control supply voltage, the supply voltage, or digital inputs/digital
• Dispensing with IO modules saves space in the control outputs are not connected to self-limiting current sources or
cabinet energy sources, see Equipment Manual or the technical product
data sheet.
• All essential timing and interlocking functions for reversing
duty and star-delta (wye-delta) starting are integrated
• No additive protection circuit required
For more information on IO-Link and AS-Interface, see
"Industrial communication", page 2/1 onwards.
SIRIUS 3RA2711 function modules for IO-Link for mounting on 3RT2 contactors
By grouping up to four starters, it is possible to connect up to at the ET 200SP or S7-1200 master and at the switching devices,
16 starters to one master of the ET 200SP or S7-1200. In this the wiring can be further reduced by connecting the supply
case all the signals of the individual controls are made available voltage of the contactor coils to the communication wires via
directly in the process image of the input through only three jumpers.
individual wires per starter group. If the same potential is present

Group formation for 4 starters max. per IO-Link port


1 2 3 4
Direct-online Direct-online Reversing Reversing
IO-link master starter starter starter starter

Port 1

NSB0_02087b

...
Port 2

Group formation with IO-Link

3/74 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data
In case of a malfunction, the corresponding error signals are Local manual operation of the complete starter group is also
also sent directly to the PLC in acyclic mode. This is in addition straightforward using a handheld device. The latter is easily
to transmission of the switching signals and status signals. connected to the last starter and can be built into the front panel
of the control cabinet if required. This offers significant
Possible error signals: advantages particularly for commissioning.
• Switching element defective
SIRIUS function modules with IO-Link are used above all in
• No main voltage (motor starter protector tripped) machines and plants in which there are several motor feeders
• No control supply voltage in one control cabinet. Using IO-Link, the connection of these
• Limit position on the right/on the left feeders to the automation level is easy, quick and error-free.

3
And with IO modules no longer needed, the width of the PLC
• Manual mode is far smaller.
• Process image fault
This easy integration of the starters in the TIA world does not limit
the flexibility in the field in the least. For example, all function
modules have special terminals in order to enable direct local
disconnection. These terminals can be connected for example
to a position switch. The input interrupts the voltage supply to
the contactor coil directly, i.e. without going through the PLC.
These terminals are jumpered in the delivery state.

SIRIUS 3RA2712 function modules for AS-Interface for mounting on 3RT2 contactors

Direct-on-line starter Reversing starter Star-delta (wye-delta) starter

NSB0_02088b
Addr. 1a Addr. 1b Addr. 2a
AS-Interface

Topology with AS-Interface


This easy integration of the starters in the TIA world does not limit SIRIUS function modules with AS-Interface are recommended
the flexibility in the field in the least. For example, all function above all in machines and plants requiring easy connection of
modules have special terminals in order to enable direct local several different sensors and actuators both inside and outside
disconnection. These terminals can be connected for example the control cabinet to the higher-level control system. And with
to a position switch. The input interrupts the voltage supply to IO modules no longer needed, the width of the PLC is far smaller.
the contactor coil directly, i.e. without going through the PLC.
These terminals are jumpered in the delivery state.

Siemens IC 10 · 2023 3/75


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data

■ Technical specifications
More information
TIA Selection Tool Cloud (TST Cloud), see FAQs
www.siemens.com/tstcloud/?node=Contactor • SIRIUS 3RT2 contactors and SIRIUS 3RH2 contactor relays, see
Technical specifications https://support.industry.siemens.com/cs/ww/en/ps/16208/faq
• SIRIUS 3RT2 contactors and SIRIUS 3RH2 contactor relays, see • SIRIUS 3RT1 contactors, see
https://support.industry.siemens.com/cs/ww/en/ps/16208/td https://support.industry.siemens.com/cs/ww/en/ps/16209/faq
• SIRIUS 3RT1 contactors, see System Manual for modular system, see
3

https://support.industry.siemens.com/cs/ww/en/ps/16209/td https://support.industry.siemens.com/cs/ww/en/view/60311318
Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60306557

Solid-state time-delay auxiliary switches


for mounting on 3RT201 to 3RT204 (sizes S00 to S3) and 3RH2 contactor relays (size S00)
Type 3RA2813 3RA2814 3RA2815
Function ON-delay OFF-delay OFF-delay without
with control signal control signal
General data
Dimensions See 3RT2 contactors (pages 3/29, 3/32, 3/35, 3/38) and
(basic unit with mounted solid-state time-delay auxiliary switch) 3RH2 contactor relays (page 5/8)
Rated insulation voltage Ui V AC 300
Pollution degree 3, overvoltage category III
Rated impulse withstand voltage Uimp kV AC 4
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -40 ... +80
Electromagnetic compatibility (EMC) IEC 61000-6-2, IEC 61000-6-4, IEC 61812-1, IEC 60947-4-1
Overvoltage protection Varistor integrated
Control
Operating range of excitation 0.85 ... 1.1 x Us,
0.95 ... 1.05 times the rated frequency
Rated power W 1
• Power consumption at 230 V AC, 50 Hz VA 2
Recovery time ms 150 --
Minimum ON duration ms -- 35 200
Setting accuracy, typ., with reference to upper limit of scale  15%
Repeat accuracy, max.  1%
Load side
Rated operational currents Ie
• AC-15 at 24 ... 250 V, 50 Hz A 3
• DC-13 - At 24 V A 1
- At 125 V A 0.2
- At 250 V A 0.1
Mechanical endurance Operat- 10 x 106
ing
cycles
Electrical endurance at AC-15, 250 V, 3 A Operat- 100 000
ing
cycles
Residual current, max. mA --
Voltage drop, max., with conducting output VA --
Short-circuit protection
• Fuse links, operational class gG: DIAZED, type 5SB A 4

3/76 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data

Type 3RA2813 3RA2814 3RA2815


Function ON-delay OFF-delay OFF-delay without
with control signal control signal
Conductor cross-sections
Connection type Screw terminals
(1 or 2 conductors can be connected)
• Solid mm2 1 x (0.5 ... 4), 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)

3
• Terminal screws M3 (for standard screwdriver size 2 or Pozidriv 2)
• Tightening torque Nm 0.8 ... 1.2
Connection type Spring-loaded terminals
(1 or 2 conductors can be connected)
• Solid mm2 2 x (0.25 ... 1.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.25 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (24 ... 16)
• Operating devices mm 3.0 x 0.5

Solid-state time-delay auxiliary switches, for snapping onto 3RT1 contactors


Type 3RT1926-2E, Type 3RT1926-2E,
3RT1926-2F, 3RT1926-2F,
3RT1926-2G 3RT1926-2G
Sizes S6 to S12 Sizes S6 to S12
General data Load side
Dimensions (W x H x D) mm 33 x 46 x 73 Rated operational currents Ie
Rated insulation voltage Ui V AC 300 • AC-15, 230 V, 50 Hz A 3
Pollution degree 3, • DC-13, 24 V A 1
overvoltage category III according to
IEC 60664-1 • DC-13, 110 V A 0.2
Permissible ambient temperature • DC-13, 230 V A 0.1
• During operation °C -25 ... +60 Short-circuit protection
• During storage °C -40 ... +85 Fuse links, operational class gG: A 4
DIAZED, type 5SB
Electromagnetic compatibility IEC 61812-1
(EMC) Mechanical endurance Operat- 10 x 106
ing
Control cycles
Operating range of excitation 0.85 ... 1.1 x Us, Conductor cross-sections
0.95 ... 1.05 times the
rated frequency Connection type Screw terminals
(1 or 2 conductors can be connected)
Rated power W 2
• Solid mm2 2 x (0.5 ... 1.5),
Power consumption at 230 V AC, VA 4 2 x (0.75 ... 4)
50 Hz
• Finely stranded with end sleeve mm2 2 x (0.5 ... 2.5)
Recovery time ms 150
• AWG cables, solid or stranded AWG 2 x (18 ... 14)
Minimum ON duration ms 200
(with OFF-delay) • Terminal screws M3
Setting accuracy, typ., %  15 • Tightening torque Nm 0.8 ... 1.2
with reference to upper limit of scale
Repeat accuracy, max. % 1

Siemens IC 10 · 2023 3/77


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data
Coupling links for control by PLC
Type 3RH2924-1GP11 3RH2914-.GP11
Mounting on contactors of size S0 S00 to S3
General data
Standards IEC 60947
Rated insulation voltage Ui (pollution degree 3) V 300
Protective separation between coil and contacts V AC Up to 300
According to IEC 60947-1, Annex N
3

Permissible ambient temperature


• During operation °C -25 ... +60
• During storage °C -40 ... +80
Control side
Rated control supply voltage Us V DC 24
Operating range V DC 17 ... 30
Power consumption at Us W 0.5
Nominal current input mA 20
Release voltage V 4
Function display Yellow LED
Protection circuit Varistors
Load side
Mechanical endurance Operating 20 million 10 million
cycles
Electrical endurance at Ie Operating 0.1 million
cycles
Switching frequency 1/h 5 000
Make-time ms Approx. 7
Break-time ms Approx. 4
Bounce time ms Approx. 2
Contact material AgSnO2
Switching voltage V AC/DC 24 ... 250
Rated operational current Ie
• AC-15/AC-14 at 230 V A 3
• DC-13 at 230 V A 0.1
Permissible residual current of the electronics (with 0 signal) mA 2.5
Conductor cross-sections
Connection type Screw terminals
(1 or 2 conductors can be connected)
2
• Solid mm 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)
• Terminal screws M3
Connection type Spring-loaded terminals
(1 or 2 conductors can be connected)
• Solid mm2 -- 2 x (0.25 ... 1.5)
• Finely stranded with end sleeve (DIN 46228) mm2 -- 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 -- 2 x (0.25 ... 1.5)
• AWG cables, solid or stranded AWG -- 2 x (24 ... 16)
• Operating devices mm -- 3.0 x 0.5

3/78 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data
3RA28 function modules for mounting on 3RT2 contactors and 3RH2 contactor relays
Type 3RA2811 3RA2831 3RA2812 3RA2832 3RA2816
Mounting on contactors of size S00, S0 S2, S3 S00, S0 S2, S3 S00 to S3
Function For direct-on-line starting For star-delta (wye-
delta) starting
ON-delay OFF-delay
with control signal
General data

3
Dimensions (basic unit with mounted function module) See 3RT2 contactors (pages 3/29, 3/32, 3/35, 3/38) and
3RH2 contactor relays (page 5/8)
Rated insulation voltage Ui V AC 300
Pollution degree 3,
overvoltage category III
Rated impulse withstand voltage Uimp kV AC 4
Overvoltage protection Varistor integrated
Recovery time ms 50 150
Minimum ON duration ms -- 35 --
Setting accuracy, typ.,  15%
with reference to upper limit of scale
Repeat accuracy, max.  1%
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -40 ... +80
Electromagnetic compatibility (EMC) IEC 61000-6-2, IEC 61000-6-4, IEC 61812-1, IEC 60947-4-1
Control side
Operating range of excitation 0.85 ... 1.1 x Us,
0.95 ... 1.05 times the rated frequency
Rated power W 1
• Power consumption at 230 V AC, 50 Hz VA 1 2
Load side
Mechanical endurance Operating 100 x 106 10 x 106
cycles
Electrical endurance
• With 3RT2028 contactor Operating 100 000 --
cycles
• At AC-15, 250 V, 3 A Operating -- 100 000
cycles
Residual current, max. mA 5 -- --
Voltage drop, max., with conducting output VA 3.5 -- --
Short-circuit protection
Version of the fuse link required for short-circuit protection of A -- Fuse gL/gG: 4
the auxiliary switch
Conductor cross-sections
Connection type Screw terminals
(1 or 2 conductors can be connected)
• Solid mm2 1 x (0.5 ... 4), 2 x (0.5 ... 2.5) --
• Finely stranded with end sleeve (DIN 46228) mm2 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.5) --
• AWG cables, solid or stranded AWG 2 x (20 ... 14) --
• Terminal screws M3 (for standard screwdriver size 2 or Pozidriv 2) --
• Tightening torque Nm 0.8 ... 1.2 --
Connection type Spring-loaded terminals
(1 or 2 conductors can be connected)
• Operating devices mm 3.0 x 0.5 --
• Solid mm2 2 x (0.25 ... 1.5) --
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.25 ... 1.5) --
• Finely stranded without end sleeve mm2 2 x (0.25 ... 1.5) --
• AWG cables, solid or stranded AWG 2 x (24 ... 16) --

Siemens IC 10 · 2023 3/79


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > General data
3RA27 function modules for IO-Link for mounting on 3RT2 contactors
Type 3RA2711
General data
Dimensions See 3RT2 contactors: pages 3/29, 3/32, 3/35 and 3/38
Suitable for IO-Link masters according to specification 1.1
Permissible ambient temperature
• During operation According to °C -25 ... +60
IEC 60947-1
3

• During storage According to °C -40 ... +80


IEC 60721-3-1
• During transport According to °C -40 ... +80
IEC 60721-3-2
Operational voltage UHi V DC 24  20%
Max. length of the cables for the input Y1-Y2 m 30
Electromagnetic compatibility (EMC) IEC 61000-6-2, IEC 61000-6-4, IEC 60947-4-1
Conductor cross-sections
Connection type Screw terminals
(1 or 2 conductors can be connected)
• Solid mm2 1 x (0.5 ... 4), 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
• Terminal screws M3 (for standard screwdriver Ø 6 mm or Pozidriv 2)
• Tightening torque of the terminal screws Nm 0.8 ... 1.2
Connection type Spring-loaded terminals
(1 or 2 conductors can be connected)
• Operating devices mm 3.0 x 0.5
• Solid mm2 2 x (0.25 ... 1.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.25 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (24 ... 16)

3RA27 function modules for AS-Interface for mounting on 3RT2 contactors


Type 3RA2712
General data
Dimensions See 3RT2 contactors: pages 3/29, 3/32, 3/35 and 3/38
Slave type A/B slave
Suitable for AS-i masters according to specification 2.1 or higher
AS-i slave profile IO.ID.ID2 7.A.E
ID1 code (factory setting) 7
Permissible ambient temperature
• During operation According to °C -25 ... +60
IEC 60947-1
• During storage According to °C -40 ... +80
IEC 60721-3-1
• During transport According to °C -40 ... +80
IEC 60721-3-2
Operational voltage
• AS-Interface V 26.5 ... 31.6
• AUX PWR 24 V DC V 24  20%
Current consumption, max.
• AS-Interface mA 30
• AUX PWR
- Maximum pickup/hold current Size S00 mA 200/200
Size S0 mA 300/300
Size S2 mA 1 300/50
Size S3 mA 4 000/70
Max. length of the cables for the input Y1-Y2 m 30
Electromagnetic compatibility (EMC) IEC 61000-6-2, IEC 61000-6-4, IEC 60947-4-1
Conductor cross-sections
Connection type Screw terminals
(1 or 2 conductors can be connected)
• Solid mm2 1 x (0.5 ... 4), 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
• Terminal screws M3 (for standard screwdriver Ø 6 mm or Pozidriv 2)
• Tightening torque of the terminal screws Nm 0.8 ... 1.2
Connection type Spring-loaded terminals
(1 or 2 conductors can be connected)
• Operating devices mm 3.0 x 0.5
• Solid mm2 2 x (0.25 ... 1.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.25 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (24 ... 16)

3/80 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous

■ Overview
Auxiliary switch: Terminal designations and identification numbers for auxiliary contacts
Terminal designations Identification numbers
The terminal designations are 2-digit, e.g. 13, 14, 21, 22: The identification number indicates the number and type of the
• Tens digit: Sequence digit auxiliary contacts, e.g. 40, 31, 22, 13:
- Related terminals have the same sequence digit • 1st digit: number of normally open contacts (NO)
• 2nd digit: number of normally closed contacts (NC)

3
• Units digit: Function digit
- 1-2 for normally closed contacts (NC) Examples:
- 3-4 for normally open contacts (NO) • 31 = 3 NO + 1 NC
• 40 = 4 NO
Selection aid for mountable auxiliary switches for power contactors and contactor relays
The auxiliary switches of the 3RH29 series for mounting on the
front and side can be used for 3RT2 power contactors as well as Example 1 Example 2
for 3RH2 contactor relays. Type 3RT20 motor contactor, 3RT20 motor contactor,
S00 with 1 NO S0 with 1 NO + 1 NC
The possible combinations of basic unit and mounted auxiliary
switch can be found in the tables, see the following pages.
1 3 5
Where the columns and lines intersect (blue and green in the
SIRIUS
example) you will find the identification number for the 3. 4. 5. 6.
combination of basic unit (column) and auxiliary switch (line). 13 21 A1
1 3 5 13
SIRIUS
A1
2. 3. 4. 5.
Additional auxiliary switch 3-pole contactors
Article number Auxiliary contacts 3RT201 3RT201 3RT202
to
3RT204 3. 4. 5. 6.
Version S00 S00 S0 to S3 14 22 A2
NO NC 10 01 11 2. 3. 4. 5.
2 4 6
13 21 13 21 2 4 6 14 A2
Sequence
digit 2. 3. 4. 5. 3. 4. 5. 6.
14 22 14 22
Type Auxiliary switch with 4 NC, Auxiliary switch with 3 NC,
2. 3. 4. 5. 5. 6. 7. 8. 3. 4. 5. 6.
3RH2911-.FA04 3RH2911-.HA03
According to EN 500121)
.1 .1 .1 .1 .1 .1 .1
Auxiliary switches without NO contact
3RH2911- HA01 -- 1 .1 11 02 12

.2
.2 .2 .2 .2 .2 .2 .2
3RH2911- HA02 -- 2 .1 .1 12 03 13
Function 1. 1. 1. 1. 1. 1. 1.
digit 2. 2. 2. 2. 2. 2. 2.
.2 .2 Combi- 3RT20 motor contactor, 3RT20 motor contactor,
3RH2911- HA03 -- 3 .1 .1 .1 13 04 14 nation S00 with aux. switch S0 with aux. switch

.2 .2 .2
3RH2911- FA04 -- 4 .1 .1 .1 .1 14 -- --
IC01_00716

SIRIUS
3. 4. 5. 6.
.2 .2 .2 .2 13 21 A1
Auxiliary switch with 1 NO contact SIRIUS
13 A1 .1 .1
.1
2. 3. 4. 5.
3RH2911- HA10 1 -- .3 20 11 21
.1 .1 .1 .1

.4
.2 .2 .2
1 For screw terminals
14 22 A2
2 For spring-loaded terminals
.2 .2 .2 .2
1)
Combinations according to EN 50012, EN 50011 and IEC 60947-5-1 are in 14 A2
IC01_00717a

bold print. All combinations comply with EN 50005.


Terminal 13 21 31 41 51 13 21 31 41 51
Example 1 designation 14 22 32 42 52 14 22 32 42 52
Basic unit: 3-pole 3RT2017 motor contactor with 1 NO Result Ident. No. 14 Ident. No. 14
Required: 1 NO + 4 NC (Ident. No. 14)
Result: 3RH2911-.FA04 auxiliary switch
Example 2
Basic unit: 3-pole 3RT2023 motor contactor with 1 NO + 1 NC
Required: 1 NO + 4 NC (Ident. No. 14)
Result: 3RH2911-.HA03 auxiliary switch

Siemens IC 10 · 2023 3/81


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous

Additional auxiliary switches 3-pole contactors 4-pole contactors Contactor relays


Article number Auxiliary contacts S00 S0 to S3 S00 S0 to S3 S00
Version 3RT201 3RT202, 3RT231 3RT251 3RT232, 3RT252, 3RH21, 3RH24
3RT203, 3RT233, 3RT253,
3RT204, 3RT234 3RT254
3RT244
NO NC 10 01 11 -- -- 11 11 40E 31E 22E
13 21 13 21 13 21 13 21 13 23 33 43 13 21 33 43 13 21 31 43
3

14 22 14 22 14 22 14 22 14 24 34 44 14 22 34 44 14 22 32 44
2. 3. 4. 5. 5. 6. 7. 8. 3. 4. 5. 6. 1. 2. 3. 4. 1. 2. 3. 4. 3. 4. 5. 6. 3. 4. 5. 6. 5. 6. 7. 8. 5. 6. 7. 8. 5. 6. 7. 8.
According to EN 500121) According to EN 500121) According to EN 500111)
Auxiliary switches, front
Without NO contact
3RH2911-@HA01 -- 1 .1 11 02 12 01 01 12 12 41X 32X 23X

.2
3RH2911-@HA02 -- 2 .1 .1 12 03 13 02 02 13 -- 42E 33X 24

.2 .2
3RH2911-@HA03 -- 3 .1 .1 .1 13 04 14 03 -- -- -- 43 34 --

.2 .2 .2
3RH2911-@FA04 -- 4 .1 .1 .1 .1 14 -- -- -- -- -- -- 44E -- --

.2 .2 .2 .2

With 1 NO contact
3RH2911-@HA10 1 -- .3 20 11 21 10 10 21 21 50E 41E 32E

.4
3RH2911-@HA11 1 1 .1 .3 21 12 22 11 11 22 22 51X 42X 33X

.2 .4
3RH2911-@HA12 1 2 .1 .1 .3 22 13 23 12 12 23 -- 52 43 34

.2 .2 .4
3RH2911-@HA13 1 3 .1 .1 .1 .3 23 14 24 13 -- -- -- 53X 44X --

.2 .2 .2 .4

With 2 NO contacts
3RH2911-@HA20 2 -- .3 .3 30 21 31 20 20 31 31 60E 51X 42X

.4 .4
3RH2911-@HA21 2 1 .1 .3 .3 31 22 32 21 21 32 32 61 52 43

.2 .4 .4
3RH2911-@HA22 2 2 .1 .1 .3 .3 32 23 33 22 22 33 -- 62X 53 44X

.2 .2 .4 .4
3RH2911-@FA22 2 2 .3 .1 .1 .3 32 23 33 22 22 33 -- 62X 53 44X

.4 .2 .2 .4
With 3 NO contacts
3RH2911-@HA30 3 -- .3 .3 .3 40 31 41 30 30 41 41 70 61 52

.4 .4 .4
3RH2911-@HA31 3 1 .1 .3 .3 .3 41 32 42 31 31 42 42 71X 62X 53X

.2 .4 .4 .4

With 4 NO contacts
3RH2911-@FA40 4 -- .3 .3 .3 .3 50 41 51 40 40 51 51 80E 71X 62X

.4 .4 .4 .4
1) Combinations according to EN 50012, EN 50011 and IEC 60947-5-1 are in bold print. All combinations comply with EN 50005.

3/82 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous

Additional auxiliary switches 3-pole contactors 4-pole contactors Contactor relays


Article number Auxiliary contacts S00 S0 to S3 S00 S0 to S3 S00
Version 3RT201 3RT202, 3RT231 3RT251 3RT232, 3RT252, 3RH21, 3RH24
3RT203, 3RT233, 3RT253,
3RT204, 3RT234 3RT254
3RT244
NO NC S00 S0 to S3 S00 S0 to S3 40E 31E 22E
13 21 13 21 13 21 13 21 13 23 33 43 13 21 33 43 13 21 31 43

3
14 22 14 22 14 22 14 22 14 24 34 44 14 22 34 44 14 22 32 44
2. 3. 4. 5. 5. 6. 7. 8. 3. 4. 5. 6. 1. 2. 3. 4. 1. 2. 3. 4. 3. 4. 5. 6. 3. 4. 5. 6. 5. 6. 7. 8. 5. 6. 7. 8. 5. 6. 7. 8.
According to EN 50005 According to EN 50005 According to EN 50005
Auxiliary switches, front
(continued)
With make-before-break1)
3RH2911-@FB11 1 1 .7 .5 21 12 22 11 11 22 22 51 42 33

.8 .6
3RH2911-@FB22 2 2 .3 .1 .5 .7 32 23 33 22 22 33 -- 62 53 44

.4 .2 .6 .8
3RH2911-@FC22 2 2 .7 .7 .5 .5 32 23 33 22 22 33 -- 62 53 44

.8 .8 .6 .6

Complete inscription with terminals from top or bottom


3RH2911-1AA10 1 -- 73 20 11 21 10 10 21 21 50 41 32

74
3RH2911-1BA10 1 -- 73 20 11 21 10 10 21 21 50 41 32

74
3RH2911-1AA01 -- 1 71 11 02 12 01 01 12 12 41 32 23

72
3RH2911-1BA01 -- 1 71 11 02 12 01 01 12 12 41 32 23

72
3RH2911-1LA11 1 1 73 81 21 12 22 11 11 22 22 51 42 33

74 82
3RH2911-1MA11 1 1 73 81 21 12 22 11 11 22 22 51 42 33

74 82
3RH2911-1LA20 2 -- 73 83 30 21 31 20 20 31 31 60 51 42

74 84
3RH2911-1MA20 2 -- 73 83 30 21 31 20 20 31 31 60 51 42

74 84
1) Contacts with make-before-break have no mirror contact function.

Siemens IC 10 · 2023 3/83


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous

Additional auxiliary switches 3-pole contactors 4-pole contactors Contactor relays


Article number Auxiliary contacts S00 S0 to S3 S00 S0 to S3 S00
Version 3RT201 3RT202, 3RT231 3RT251 3RT232, 3RT252, 3RH21, 3RH24
3RT203, 3RT233, 3RT253,
3RT204, 3RT234 3RT254
3RT244
NO NC 10 01 11 -- -- 11 11 40E 31E 22E
13 21 13 21 13 21 13 21 13 23 33 43 13 21 33 43 13 21 31 43
3

14 22 14 22 14 22 14 22 14 24 34 44 14 22 34 44 14 22 32 44
2. 3. 4. 5. 5. 6. 7. 8. 3. 4. 5. 6. 1. 2. 3. 4. 1. 2. 3. 4. 3. 4. 5. 6. 3. 4. 5. 6. 5. 6. 7. 8. 5. 6. 7. 8. 5. 6. 7. 8.
According to EN 50005 According to EN 50005 According to EN 500111)
Auxiliary switches, front
(continued)
With complete inscription (for contactor relays)2)
3RH2911-@GA40 4 -- 53 63 73 83 -- -- -- -- -- -- -- 80E -- --

54 64 74 84
3RH2911-@GA31 3 1 53 61 73 83 -- -- -- -- -- -- -- 71E -- --

54 62 74 84
3RH2911-@GA22 2 2 53 61 71 83 -- -- -- -- -- -- -- 62E -- --

54 62 72 84
3RH2911-@GA13 1 3 53 61 71 81 -- -- -- -- -- -- -- 53E -- --

54 62 72 82
3RH2911-@GA04 -- 4 51 61 71 81 -- -- -- -- -- -- -- 44E -- --

52 62 72 82
Complete inscription
3RH2911-@XA40 4 -- 53 63 73 83 50 41 51 40 40 51 51 80E 71X 62X
-0MA0

54 64 74 84
3RH2911-@XA31 3 1 53 61 73 83 41 32 42 31 31 42 42 71E 62X 53
-0MA0

54 62 74 84
3RH2911-@XA22 2 2 53 61 71 83 32 23 33 22 22 33 -- 62E 53 44X
-0MA0

54 62 72 84
3RH2911-@XA04 -- 4 51 61 71 81 14 -- -- -- -- -- -- 44E -- --
-0MA0

52 62 72 82
Solid-state compatible3)
3RH2911-2NE21 24) 1 .3 .3 .1 31 22 32 21 21 32 32 61 52 43

.4 .4 .2
3RH2911-1NE22 24) 24) .3 .3 .1 .1 32 23 33 22 22 33 -- 62 53 44

.4 .4 .2 .2
3RH2911-@NF02 -- 2 .1 .1 12 03 13 02 02 13 -- 42 33 24

.2 .2
3RH2911-@NF11 1 1 .3 .1 21 12 22 11 11 22 22 51 42 33

.4 .2
3RH2911-@NF20 2 -- .3 .3 30 21 31 20 20 31 31 60 51 42

.4 .4
1) 3)
Combinations according to EN 50011 and IEC 60947-5-1 are in bold print. The internal circuit diagrams shown apply to sizes S00 to S3 (including
All combinations comply with EN 50005. mirror contacts). If size S00 is used for the contactor relays, the function of
2) For selection and ordering data, see page 3/89. the mirror contact is not needed.
4) Of which one auxiliary contact is not solid-state compatible.

3/84 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous

Additional auxiliary switches 3-pole contactors 4-pole contactors Contactor relays


Article number Auxiliary S00 S0 to S3 S00 S0 to S3 S00
contacts
Version 3RT201 3RT202, 3RT231 3RT251 3RT232, 3RT252, 3RH21
3RT203, 3RT233, 3RT253,
3RT204, 3RT234 3RT254
3RT244
NO NC 10 01 11 -- -- 11 11 40E 31E 22E
21 13 21 13 21 13 21 13 23 33 43 13 21 33 43 13 21 31 43

3
13

14 22 14 22 14 22 14 22 14 24 34 44 14 22 34 44 14 22 32 44
2. 3. 4. 5. 5. 6. 7. 8. 3. 4. 5. 6. 1. 2. 3. 4. 1. 2. 3. 4. 3. 4. 5. 6. 3. 4. 5. 6. 5. 6. 7. 8. 5. 6. 7. 8. 5. 6. 7. 8.
According to EN 500121) According to EN 500121) According to EN 500111)
Lateral auxiliary switches
For size S00 Left Right
3RH2911-@DA02 -- 2 -- 21 31 12 -- -- 02 02 -- -- -- -- --

22 32

3RH2911-@DA02 -- 2 41 51 21 31 14 -- -- -- -- -- -- -- -- --
+
3RH2911-@DA02 -- 2
42 52 22 32

3RH2911-@DA11 1 1 -- 21 33 21 -- -- 11 11 -- -- -- -- --

22 34

3RH2911-@DA11 1 1 41 53 21 33 32 -- -- 22 22 -- -- -- -- --
+
3RH2911-@DA11 1 1
42 54 22 34

3RH2911-@DA20 2 -- -- 23 33 30 -- -- 20 20 -- -- -- -- --

24 34

3RH2911-@DA20 2 -- 43 53 23 33 50 -- -- 40 40 -- -- -- -- --
+
3RH2911-@DA20 2 --
44 54 24 34

3RH2911-@DA20 2 -- 43 53 21 33 41 -- -- 31 31 -- -- -- -- --
+
3RH2911-@DA11 1 1
44 54 22 34

3RH2911-@DA20 2 -- 43 53 21 31 32 -- -- 22 22 -- -- -- -- --
+
3RH2911-@DA02 -- 2
44 54 22 32

3RH2911-@DA11 1 1 41 53 21 31 23 -- -- 13 -- -- -- -- -- --
+
3RH2911-@DA02 -- 2
42 54 22 32

For sizes S0 to S3 Left Right


3RH2921-@DA02 -- 2 -- 31 41 12 03 13 02 02 13 -- -- -- --

32 42

3RH2921-@DA02 -- 2 51 61 31 41 14 -- -- -- -- -- -- -- -- --
+
3RH2921-@DA02 -- 2
52 62 32 42

3RH2921-@DA11 1 1 -- 31 43 21 12 22 11 11 22 22 -- -- --

32 44

3RH2921-@DA11 1 1 51 63 31 43 32 23 33 22 22 -- -- -- -- --
+
3RH2921-@DA11 1 1
52 64 32 44

3RH2921-@DA20 2 -- -- 33 43 30 21 31 20 20 31 31 -- -- --

34 44

3RH2921-@DA20 2 -- 53 63 33 43 50 41 51 40 40 -- -- -- -- --
+
3RH2921-@DA20 2 --
54 64 34 44

1) Combinations according to EN 50012, EN 50011 and IEC 60947-5-1 are in bold print. All combinations comply with EN 50005.

Siemens IC 10 · 2023 3/85


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous

Additional auxiliary switches 3-pole contactors 4-pole contactors Contactor relays


Article number Auxiliary contacts S00 S0 to S3 S00 S0 to S3 S00
Version 3RT201 3RT202, 3RT231 3RT251 3RT232, 3RT252, 3RH21
3RT203, 3RT233, 3RT253,
3RT204, 3RT234 3RT254
3RT244
NO NC 10 01 11 -- -- 11 11 40E 31E 22E
13 21 13 21 13 21 13 21 13 23 33 43 13 21 33 43 13 21 31 43
3

14 22 14 22 14 22 14 22 14 24 34 44 14 22 34 44 14 22 32 44
2. 3. 4. 5. 5. 6. 7. 8. 3. 4. 5. 6. 1. 2. 3. 4. 1. 2. 3. 4. 3. 4. 5. 6. 3. 4. 5. 6. 5. 6. 7. 8. 5. 6. 7. 8. 5. 6. 7. 8.
According to EN 500121) According to EN 500121) According to EN 500111)
Lateral auxiliary switches
(continued)
For sizes S00 to S3 Left Right
3RH2921-@DA20 2 -- 53 63 31 43 41 32 42 31 31 -- -- -- -- --
+
3RH2921-@DA11 1 1
54 64 32 44

3RH2921-@DA20 2 -- 53 63 31 41 32 23 33 22 22 -- -- -- -- --
+
3RH2921-@DA02 -- 2
54 64 32 42

3RH2921-@DA11 1 1 51 63 31 41 23 14 24 13 -- -- -- -- -- --
+
3RH2921-@DA02 -- 2
52 64 32 42

For contactor relays2) Left


3RH2921-@DA02 -- 2 51 61 -- -- -- -- -- -- -- 42Z 33X 24

52 62

3RH2921-@DA11 1 1 51 63 -- -- -- -- -- -- -- 51X 42X 33X

52 64

3RH2921-@DA20 2 -- 53 63 -- -- -- -- -- -- -- 60Z 51X 42X

54 64

Solid-state compatible
For size S00 Left Right
3RH2911-2DE11 1 1 -- 23 31 21 -- -- 11 11 -- -- -- -- --

24 32

3RH2911-2DE11 1 1 41 53 23 31 32 -- -- 22 22 -- -- -- -- --
+
3RH2911-2DE11 1 1
42 54 24 32

For sizes S00 to S3 Left Right


3RH2921-@DE11 1 1 -- 33 41 21 12 22 11 11 22 22 -- -- --

34 42

3RH2921-@DE11 1 1 51 63 33 41 32 23 33 22 22 -- -- -- -- --
+
3RH2921-@DE11 1 1
52 64 34 42

For contactor relays2) Left


3RH2921-2DE11 1 1 51 63 -- -- -- -- -- -- -- 51X 42X 33X

52 64
1)
Combinations according to EN 50012, EN 50011 and IEC 60947-5-1 are in
bold print. All combinations comply with EN 50005.
2) Without force-guided operation.

3/86 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous

■ Selection and ordering data


PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RH2911-1HA22 3RH2911-2HA22
For contactors/ Auxiliary contacts Screw terminals Spring-loaded terminals
contactor relays1) Version
Article No. Price Article No. Price
per PU per PU

Type NO NC
Auxiliary switches for snapping onto the front
Sizes S00 to S3
3RT2.1, -- 1 .1 3RH2911-1HA01 3RH2911-2HA01
3RT2.2,
3RT2.3,
3RT2.4, .2
3RH21, -- 2 .1 .1 3RH2911-1HA02 3RH2911-2HA02
3RH24

.2 .2

-- 3 .1 .1 .1 3RH2911-1HA03 3RH2911-2HA03

.2 .2 .2

1 -- .3 3RH2911-1HA10 3RH2911-2HA10

.4

1 1 .1 .3 3RH2911-1HA11 3RH2911-2HA11

.2 .4
1 2 .1 .1 .3 3RH2911-1HA12 3RH2911-2HA12

.2 .2 .4
1 3 .1 .1 .1 .3 3RH2911-1HA13 3RH2911-2HA13

.2 .2 .2 .4
2 -- .3 .3 3RH2911-1HA20 3RH2911-2HA20

.4 .4
2 1 .1 .3 .3 3RH2911-1HA21 3RH2911-2HA21

.2 .4 .4
2 2 .1 .1 .3 .3 3RH2911-1HA22 3RH2911-2HA22

.2 .2 .4 .4
3 -- .3 .3 .3 3RH2911-1HA30 3RH2911-2HA30

.4 .4 .4
3 1 .1 .3 .3 .3 3RH2911-1HA31 3RH2911-2HA31

.2 .4 .4 .4
1) For detailed information on use, see page 3/82.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/87
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RH2911-1FC22 3RH2911-2FC22 3RH2911-1AA01 3RH2911-1BA01 3RH2911-1LA11 3RH2911-1MA11


For contactors/ Connections Auxiliary contacts Screw terminals Spring-loaded terminals
contactor relays1) Position Version
Article No. Price Article No. Price
per PU per PU

Type NO NC NO NC
Auxiliary switches for snapping onto the front
Sizes S00 to S3
3RT2.1, -- 4 -- -- -- .3 .3 .3 .3 3RH2911-1FA40 3RH2911-2FA40
3RT2.2,
3RT2.3,
3RT2.4, .4 .4 .4 .4
3RH21, -- 2 2 -- -- .3 .1 .1 .3 3RH2911-1FA22 3RH2911-2FA22
3RH24

.4 .2 .2 .4
-- -- 4 -- -- .1 .1 .1 .1 3RH2911-1FA04 3RH2911-2FA04

.2 .2 .2 .2
-- -- -- 1 1 .7 .5 3RH2911-1FB11 3RH2911-2FB11

.8 .6
-- 1 1 1 1 .3 .1 .5 .7 3RH2911-1FB22 3RH2911-2FB22

.4 .2 .6 .8
-- -- -- 2 2 .7 .7 .5 .5 3RH2911-1FC22 3RH2911-2FC22

.8 .8 .6 .6
1-pole and 2-pole auxiliary switches, cable entry from top or bottom
3RT2.1, Top 1 -- -- -- 73 3RH2911-1AA10 --
3RT2.2, Bottom 1 -- -- -- 3RH2911-1BA10 --
3RT2.3,
3RT2.4, 74
3RH21, Top -- 1 -- -- 71 3RH2911-1AA01 --
3RH24
Bottom -- 1 -- -- 3RH2911-1BA01 --
72
Top 1 1 -- -- 73 81 3RH2911-1LA11 --
Bottom 1 1 -- -- 3RH2911-1MA11 --
74 82
Top 2 -- -- -- 73 83 3RH2911-1LA20 --
Bottom 2 -- -- -- 3RH2911-1MA20 --
74 84
1)
For detailed information on use, see pages 3/82 and 3/83.

* You can order this quantity or a multiple thereof.


3/88 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous

PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3RH2911-1GA22 3RH2911-2GA22

3
For contactor Contactor relay with Auxiliary contacts Screw terminals Spring-loaded terminals
relays1) auxiliary switch
Ident. No. Version
Article No. Price Article No. Price
per PU per PU

Type NO NC
Auxiliary switches for snapping onto the front
Size S00
Blocks for the assembly of contactor relays with 8 contacts
3RH2140, 80E 4 -- 53 63 73 83 3RH2911-1GA40 3RH2911-2GA40
3RH2440,
Ident. No. 40E
54 64 74 84
71E 3 1 53 61 73 83 3RH2911-1GA31 3RH2911-2GA31

54 62 74 84
62E 2 2 53 61 71 83 3RH2911-1GA22 3RH2911-2GA22

54 62 72 84
53E 1 3 53 61 71 81 3RH2911-1GA13 3RH2911-2GA13

54 62 72 82
44E -- 4 51 61 71 81 3RH2911-1GA04 3RH2911-2GA04

52 62 72 82
1)
For detailed information on use, see page 3/84.
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3RH2911-1XA22-0MA0 3RH2911-2XA22-0MA0
For contactors/ Auxiliary Screw terminals Spring-loaded terminals
contactor relays1) contacts
Version
Article No. Price Article No. Price
per PU per PU

Type NO NC
Auxiliary switches for snapping onto the front
Sizes S00 to S3 S00 S0 ... S3
3RT2.1, 4 -- 53 63 73 83 53 63 73 83 3RH2911-1XA40-0MA0 3RH2911-2XA40-0MA0
3RT2.2,
3RT2.3,
3RT2.4, 54 64 74 84 54 64 74 84
3RH212), 3 1 53 61 73 83 53 61 73 83 3RH2911-1XA31-0MA0 3RH2911-2XA31-0MA0
3RH242)

54 62 74 84 54 62 74 84
2 2 53 61 71 83 53 61 71 83 3RH2911-1XA22-0MA0 3RH2911-2XA22-0MA0

54 62 72 84 54 62 72 84
-- 4 51 61 71 81 51 61 71 81 3RH2911-1XA04-0MA0 3RH2911-2XA04-0MA0

52 62 72 82 52 62 72 82
1) 2)
For detailed information on use, see page 3/84. For size S00, positively driven operation only applies for the 3RH contactor
relay, and there is no positively driven operation for 3RT2 power contactors.
* You can order this quantity or a multiple thereof.
Illustrations are approximate Siemens IC 10 · 2023 3/89
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RH1921-1XA22-0MA0 3RH1921-2XA22-0MA0 3RH1921-1CA10 3RH1921-1CD10 3RH1921-2CA10 3RH1921-2CA01


For Auxiliary contacts Screw terminals Spring-loaded terminals
contactors Ident. No. Version
Article No. Price Article No. Price
per PU per PU

Type NO NC NO NC
Auxiliary switches for snapping onto the front
Sizes S6 to S12
4-pole auxiliary switches
• According to EN 50012
3RT1.5 ... 22 2 2 -- -- 53 61 71 83 3RH1921-1XA22-0MA0 3RH1921-2XA22-0MA0
3RT1.7

54 62 72 84

1-pole auxiliary switches


• According to EN 50005 and EN 50012
3RT1.5 ... 10 1 -- -- -- .3 3RH1921-1CA10 3RH1921-2CA10
3RT1.7

.4
01 -- 1 -- -- .1 3RH1921-1CA01 3RH1921-2CA01

.2
10 -- -- 1 -- .7 3RH1921-1CD10 --
(lead-
ing)
.8
01 -- -- -- 1 .5 3RH1921-1CD01 --
(lag-
ging)
.6

* You can order this quantity or a multiple thereof.


3/90 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RH2911-1DA02 3RH2911-2DA02
For Auxiliary contacts Screw terminals Spring-loaded terminals
contactors/ Version
contactor
relays1)
Article No. Price Article No. Price
per PU per PU

Type NO NC
Laterally mountable auxiliary switches,
mounting on the right and/or the left,
2-pole
Size S00 Left Right
3RT2.1 -- 2 41 51 21 31 3RH2911-1DA02 3RH2911-2DA02

42 52 22 32

1 1 41 53 21 33 3RH2911-1DA11 3RH2911-2DA11

42 54 22 34

2 -- 43 53 23 33 3RH2911-1DA20 3RH2911-2DA20

44 54 24 34

3RH21, -- 2 51 61 -- 3RH2921-1DA02 3RH2921-2DA02


3RH24

52 62

1 1 51 63 -- 3RH2921-1DA11 3RH2921-2DA11

52 64

2 -- 53 63 -- 3RH2921-1DA20 3RH2921-2DA20

54 64

Sizes S0 to S3 Left Right


3RT2.22), -- 2 51 61 31 41 3RH2921-1DA02 3RH2921-2DA02
3RT2.33),
3RT2.43)
52 62 32 42

1 1 51 63 31 43 3RH2921-1DA11 3RH2921-2DA11

52 64 32 44

2 -- 53 63 33 43 3RH2921-1DA20 3RH2921-2DA20

54 64 34 44

1) 2)
For detailed information on use, see pages 3/85 and 3/86. With 3RT232. and 3RT252. contactors, mountable only on the right.
3) 3RH2921-1DA.. lateral auxiliary switches can only be mounted on 3RT26
capacitor contactors of sizes S2 and S3.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/91
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RH1921-1DA11 3RH1921-1JA11 3RH1921-1EA02 3RH1921-1KA02 3RH1921-2DA11

For contactors Auxiliary contacts Screw terminals Spring-loaded terminals


Version
Article No. Price Article No. Price
per PU per PU

Type NO NC
Lateral auxiliary switches,
mounting on the right or left,
2-pole
Sizes S6 to S12 Left Right
First auxiliary switch
• According to EN 50012
3RT1.5 ... 1 1 21 13 31 43 3RH1921-1DA11 3RH1921-2DA11
3RT1.7

22 14 32 44

• According to EN 50005
3RT1.5 ... 2 -- 53 63 73 83 3RH1921-1EA20 3RH1921-2EA20
3RT1.7

54 64 74 84
1 1 51 63 71 83 3RH1921-1EA11 --

52 64 72 84
-- 2 51 61 71 81 3RH1921-1EA02 3RH1921-2EA02

52 62 72 82

Second auxiliary switch


• According to EN 50012
3RT1.5 ... 1 1 61 53 71 83 3RH1921-1JA11 3RH1921-2JA11
3RT1.7

62 54 72 84

• According to EN 50005
3RT1.5 ... 2 -- 153 163 173 183 3RH1921-1KA20 3RH1921-2KA20
3RT1.7

154 164 174 184


1 1 151 163 171 183 3RH1921-1KA11 --

152 164 172 184


-- 2 151 161 171 181 3RH1921-1KA02 3RH1921-2KA02

152 162 172 182

* You can order this quantity or a multiple thereof.


3/92 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RH2911-1NF.. 3RH2911-2NF..
For Size Contacts Screw terminals Spring-loaded terminals
contactors/ Version
contactor
relays1)
Article No. Price Article No. Price
per PU per PU

Type NO NC
Auxiliary switches for snapping onto the front
Solid-state compatible auxiliary switches, 2-pole
• For operation in dusty atmospheres
• For solid-state circuits with rated operational currents Ie/AC-14 and DC-13 from
1 to 300 mA at 3 to 60 V
• Hard gold-plated contacts
• Auxiliary switches for snapping onto the front for 3RT2.2 to 3RT2.4 contactors are
designed as mirror contacts according to IEC 60947-4-1, Annex F.
Sizes S00 to S3 S00 S0 ... S3
3RT2.1, S00 ... S3 22) 1 .3 .3 .1 .3 .3 .1 NEW NEU -- 3RH2911-2NE21
3RT2.2,
3RT2.3,
3RT2.4 .4 .4 .2 .4 .4 .2
2) 2)
2 2 .3 .3 .1 .1 .3 .3 .1 .1 NEW NEU 3RH2911-1NE22 --

.4 .4 .2 .2 .4 .4 .2 .2

-- 2 .1 .1 .1 .1 3RH2911-1NF02 3RH2911-2NF02

.2 .2 .2 .2

1 1 .3 .1 .3 .1 3RH2911-1NF11 3RH2911-2NF11

.4 .2 .4 .2

2 -- .3 .3 .3 .3 3RH2911-1NF20 3RH2911-2NF20

.4 .4 .4 .4
2)
3RH21, S00 2 1 .3 .3 .1 -- NEW NEU -- 3RH2911-2NE21
3RH24

.4 .4 .2

22) 22) .3 .3 .1 .1 -- NEW NEU 3RH2911-1NE22 --

.4 .4 .2 .2

-- 2 .1 .1 -- 3RH2911-1NF02 3RH2911-2NF02

.2 .2

1 1 .3 .1 -- 3RH2911-1NF11 3RH2911-2NF11

.4 .2

2 -- .3 .3 -- 3RH2911-1NF20 3RH2911-2NF20

.4 .4

1)
For detailed information on use, see page 3/84.
2)
Of which one auxiliary contact is not solid-state compatible.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/93
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, instantaneous
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RH2911-2DE11 3RH1921-2JE11
For Size Contacts Screw terminals Spring-loaded terminals
contactors/ Version
contactor
relays1)
Article No. Price Article No. Price
per PU per PU

Type NO NC
Lateral auxiliary switches, mounting on the right and/or the left,
according to EN 50012
Solid-state compatible auxiliary switches, 2-pole
• For operation in dusty atmospheres
• For solid-state circuits with rated operational currents Ie/AC-14 and DC-13
from 1 to 300 mA at 3 to 60 V
• Hard gold-plated contacts
• Laterally mountable auxiliary switches for 3RT2.1 to 3RT2.4 and 3RT1.5 to 3RT1.7
contactors are designed as mirror contacts according to IEC 60947-4-1, Annex F.
Sizes S00 to S3 Left Right
Auxiliary switches
3RT2.1 S00 1 1 41 53 23 31 -- 3RH2911-2DE11

42 54 24 32

3RH21, S00 1 1 51 63 -- -- 3RH2921-2DE11


3RH24

52 64

3RT2.2, S0 ... S3 1 1 51 63 33 41 -- 3RH2921-2DE11


3RT2.3,
3RT2.4
52 64 34 42

Sizes S6 to S12 Left Right


First auxiliary switch
3RT1.5 S6 ... S12 1 1 21 13 31 43 -- 3RH1921-2DE11
...
3RT1.7
22 14 32 44
Second auxiliary switch
3RT1.5 S6 ... S12 1 1 61 53 71 83 -- 3RH1921-2JE11
...
3RT1.7
62 54 72 84
1)
Applies to 3RT2 and 3RH2 contactors: For detailed information on use,
see page 3/86.

* You can order this quantity or a multiple thereof.


3/94 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, delayed

■ Selection and ordering data


For contactors Time setting range t Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price
Type s per PU
Pneumatic time-delay auxiliary switches
for mounting on 3RT2 contactors

3
Size S0
Auxiliary contacts 1 NO and 1 NC1)
ON-delay
3RT2022) 1 ... 30 3RT2927-2PA01 1 1 unit 41B
10 ... 180 3RT2927-2PA11 1 1 unit 41B
OFF-delay
3RT2022) 1 ... 30 3RT2927-2PR01 1 1 unit 41B
3RT2927-2P..1
10 ... 180 3RT2927-2PR11 1 1 unit 41B
1)
In addition to these, no other auxiliary contacts are permitted.
2)
Cannot be fitted onto coupling contactors and coupling contactor relays.

PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3RA2813-1FW10 3RA2813-2AW10
For Rated control supply Time setting Output/ Screw terminals Spring-loaded terminals
contactors voltage Us1) range t auxiliary contacts
Article No. Price Article No. Price
Type V s per PU per PU
Solid-state time-delay auxiliary switches2)
for mounting on 3RT2 contactors and 3RH2 contactor relays
Sizes S00 to S3
The electrical connection between the solid-state time-delay auxiliary
switch and the contactor or contactor relay underneath is established
automatically when it is snapped on and locked.
ON-delay
(varistor integrated)
3RT23)4), 24 ... 240 AC/DC 0.05 ... 100 1 CO 3RA2813-1AW10 3RA2813-2AW10
3RH213), (1, 10, 100; 1 NO + 1 NC 3RA2813-1FW10 3RA2813-2FW10
3RH24 selectable)
OFF-delay with control signal
(varistor integrated)
3RT23)4), 24 ... 240 AC/DC 0.05 ... 100 1 CO 3RA2814-1AW10 3RA2814-2AW10
3RH213), (1, 10, 100; 1 NO + 1 NC 3RA2814-1FW10 3RA2814-2FW10
3RH24 selectable)
5)
OFF-delay without control signal
(varistor integrated)
3RT23)4), 24 ... 240 AC/DC 0.05 ... 100 1 CO 3RA2815-1AW10 3RA2815-2AW10
3RH213), (1, 10, 100; 1 NO + 1 NC 3RA2815-1FW10 3RA2815-2FW10
3RH24 selectable)
1) AC voltage values apply for 50 Hz and 60 Hz. Technical specifications, see page 3/76.
2)
The solid-state time-delay auxiliary switches are also available as 3RA28
function modules for mounting on 3RT2 contactors and 3RH2 contactor
relays, see page 3/100.
3)
Cannot be fitted onto coupling contactors and coupling contactor relays.
4) From product version E04 onwards, 3RA281. solid-state time-delay
auxiliary switches can be used for 3RT2.4 contactors.
5)
Setting of output contacts in as-supplied state not defined (bistable relay).
Application of the control supply voltage once results in contact
changeover to the correct setting.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/95
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Auxiliary switches, delayed

For contactors Auxiliary contacts Rated control Time setting Screw terminals PU PS* PG
supply voltage Us1) range t (UNIT,
SET, M)
Article No. Price
Type V s per PU
Solid-state time-delay auxiliary switches
for mounting on 3RT1 contactors
Sizes S6 to S12
ON-delay2)
3

3RT10, 1 NO + 1 NC 24 AC/DC 0.05 ... 1 3RT1926-2EJ11 1 1 unit 41H


3RT14 0.5 ... 10 3RT1926-2EJ21 1 1 unit 41H
5 ... 100 3RT1926-2EJ31 1 1 unit 41H
100 ... 127 AC 0.05 ... 1 3RT1926-2EC11 1 1 unit 41H
0.5 ... 10 3RT1926-2EC21 1 1 unit 41H
5 ... 100 3RT1926-2EC31 1 1 unit 41H
3RT1926-2E..1, 200 ... 240 AC 0.05 ... 1 3RT1926-2ED11 1 1 unit 41H
3RT1926-2F..1 0.5 ... 10 3RT1926-2ED21 1 1 unit 41H
5 ... 100 3RT1926-2ED31 1 1 unit 41H
OFF-delay without control signal2)3)
3RT10, 1 NO + 1 NC 24 AC/DC 0.05 ... 1 3RT1926-2FJ11 1 1 unit 41H
3RT14 0.5 ... 10 3RT1926-2FJ21 1 1 unit 41H
5 ... 100 3RT1926-2FJ31 1 1 unit 41H
100 ... 127 AC/DC 0.05 ... 1 3RT1926-2FK11 1 1 unit 41H
0.5 ... 10 3RT1926-2FK21 1 1 unit 41H
5 ... 100 3RT1926-2FK31 1 1 unit 41H
200 ... 240 AC/DC 0.05 ... 1 3RT1926-2FL11 1 1 unit 41H
0.5 ... 10 3RT1926-2FL21 1 1 unit 41H
5 ... 100 3RT1926-2FL31 1 1 unit 41H
Star-delta (wye-delta) starting (varistor integrated)2)
3RT10, 1 NO delayed + 24 AC/DC 1.5 ... 30 3RT1926-2GJ51 1 1 unit 41H
3RT14 1 NO instantaneous, 100 ... 127 AC 1.5 ... 30 3RT1926-2GC51 1 1 unit 41H
dead time 50 ms
200 ... 240 AC 1.5 ... 30 3RT1926-2GD51 1 1 unit 41H

3RT1926-2G.51
1)
AC voltage values apply for 50 and 60 Hz.
2)
Connecting terminals A1 and A2 for the control supply voltage of the solid-
state time-delay auxiliary switch must be connected to the associated
contactor by means of cables.
3) Setting of output contacts in as-supplied state not defined (bistable relay).
Application of the control supply voltage once results in contact
changeover to the correct setting.

* You can order this quantity or a multiple thereof.


3/96 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Surge suppressors

■ Selection and ordering data


For con- Version Rated control supply voltage Us1) Article No. Price PU PS* PG
tactors AC operation DC operation per PU (UNIT,
SET, M)
Type V AC V DC
Surge suppressors without LED (also for spring-loaded terminals)
Size S00
For plugging onto the front of the contactors

3
(with or without auxiliary switches)
3RT2.1, Varistors 24 ... 48 24 ... 70 3RT2916-1BB00 1 1 unit 41B
3RH2 48 ... 127 70 ... 150 3RT2916-1BC00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2916-1BD00 1 1 unit 41B
240 ... 400 -- 3RT2916-1BE00 1 1 unit 41B
3RT2916-1B.00 400 ... 600 -- 3RT2916-1BF00 1 1 unit 41B
3RT2.1, RC elements 24 ... 48 24 ... 70 3RT2916-1CB00 1 1 unit 41B
3RH2 48 ... 127 70 ... 150 3RT2916-1CC00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2916-1CD00 1 1 unit 41B
240 ... 400 -- 3RT2916-1CE00 1 1 unit 41B
400 ... 600 -- 3RT2916-1CF00 1 1 unit 41B
3RT2.1, Interference -- 12 ... 250 3RT2916-1DG00 1 1 unit 41B
3RH2 suppression
diode
3RT2.1, Diode assemblies -- 12 ... 250 3RT2916-1EH00 1 1 unit 41B
3RH2 (diode and Zener
diode) for DC
operation
Size S0
For plugging into the front of the contactors
(before mounting the auxiliary switch)
3RT2.2 Varistors2) 24 ... 48 24 ... 70 3RT2926-1BB00 1 1 unit 41B
48 ... 127 70 ... 150 3RT2926-1BC00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2926-1BD00 1 1 unit 41B
240 ... 400 -- 3RT2926-1BE00 1 1 unit 41B
3RT2926-1E.00 400 ... 600 -- 3RT2926-1BF00 1 1 unit 41B
3RT2.2 RC elements 24 ... 48 24 ... 70 3RT2926-1CB00 1 1 unit 41B
48 ... 127 70 ... 150 3RT2926-1CC00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2926-1CD00 1 1 unit 41B
240 ... 400 -- 3RT2926-1CE00 1 1 unit 41B
400 ... 600 -- 3RT2926-1CF00 1 1 unit 41B
3RT2.2 Diode assemblies -- 24 3RT2926-1ER00 1 1 unit 41B
for DC operation -- 30 ... 250 3RT2926-1ES00 1 1 unit 41B
Size S2
For plugging into the front of the contactors
(before mounting the auxiliary switch)
3RT2.3 Varistors2) 24 ... 48 -- 3RT2936-1BB00 1 1 unit 41B
48 ... 127 -- 3RT2936-1BC00 1 1 unit 41B
127 ... 240 -- 3RT2936-1BD00 1 1 unit 41B
240 ... 400 -- 3RT2936-1BE00 1 1 unit 41B
3RT2936-1BF00 400 ... 600 -- 3RT2936-1BF00 1 1 unit 41B
3RT2.3 RC elements 24 ... 48 24 ... 70 3RT2936-1CB00 1 1 unit 41B
48 ... 127 70 ... 150 3RT2936-1CC00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2936-1CD00 1 1 unit 41B
240 ... 400 -- 3RT2936-1CE00 1 1 unit 41B
400 ... 600 -- 3RT2936-1CF00 1 1 unit 41B
3RT2.3 Diode assemblies -- 24 3RT2936-1ER00 1 1 unit 41B
for DC operation -- 30 ... 250 3RT2936-1ES00 1 1 unit 41B
Size S3
For plugging into the front of the contactors
(before mounting the auxiliary switch)
3RT2.4 Varistors2) 24 ... 48 -- 3RT2936-1BB00 1 1 unit 41B
48 ... 127 -- 3RT2936-1BC00 1 1 unit 41B
127 ... 240 -- 3RT2936-1BD00 1 1 unit 41B
240 ... 400 -- 3RT2936-1BE00 1 1 unit 41B
3RT2936-1ER00 400 ... 600 -- 3RT2936-1BF00 1 1 unit 41B
3RT2.4 Diode assemblies -- 24 3RT2936-1ER00 1 1 unit 41B
for DC operation -- 30 ... 250 3RT2936-1ES00 1 1 unit 41B
For plugging into the two recesses on the left next to
the connection block for auxiliary switches and coils A1
and A2, the connecting cables are wired to A1 and A2
(see also overview graphic on page 3/11)
3RT2.4 RC elements 24 ... 48 24 ... 70 3RT2946-1CB00 1 1 unit 41B
48 ... 127 70 ... 150 3RT2946-1CC00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2946-1CD00 1 1 unit 41B
240 ... 400 -- 3RT2946-1CE00 1 1 unit 41B
400 ... 600 -- 3RT2946-1CF00 1 1 unit 41B
3RT2946-1C.00
1) Can be used for AC operation for 50/60 Hz. Other voltages on request. 2) The varistor is already integrated on the AC/DC contactors.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/97
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Surge suppressors

For con- Version Rated control supply voltage Us1) Article No. Price PU PS* PG
tactors AC operation DC operation per PU (UNIT,
SET, M)
Type V AC V DC
Surge suppressors without LED
Sizes S6 to S12
For connecting to withdrawable coil for contactors Screw terminals
with
• Standard operating mechanisms 3RT1...-.A...
3

• Solid-state operating mechanisms 3RT1...-.N...


3RT1.5 ... RC elements 24 ... 48 24 ... 70 3RT1956-1CB00 1 1 unit 41B
3RT1.7 48 ... 127 70 ... 150 3RT1956-1CC00 1 1 unit 41B
127 ... 240 150 ... 250 3RT1956-1CD00 1 1 unit 41B
3RT1956-1C.00 240 ... 400 -- 3RT1956-1CE00 1 1 unit 41B
400 ... 600 -- 3RT1956-1CF00 1 1 unit 41B
Spring-loaded terminals

3RT1.5 ... RC elements 24 ... 48 24 ... 70 3RT1956-1CB02 1 1 unit 41B


3RT1.7 48 ... 127 70 ... 150 3RT1956-1CC02 1 1 unit 41B
127 ... 240 150 ... 250 3RT1956-1CD02 1 1 unit 41B
240 ... 400 -- 3RT1956-1CE02 1 1 unit 41B
3RT1956-1C.02 400 ... 600 -- 3RT1956-1CF02 1 1 unit 41B
1)
Can be used for AC operation for 50/60 Hz. Other voltages on request.

For con- Version Rated control supply Power con- Article No. Price PU PS* PG
tactors voltage Us1) sumption P per PU (UNIT,
AC DC of LED SET, M)
operation operation at Us
Type V AC V DC mW
Surge suppressors with LED (also for spring-loaded terminals)
Size S00
For plugging onto the front of the contactors
(with or without auxiliary switches)
3RT2.1, Varistors 24 ... 48 12 ... 24 10 ... 120 3RT2916-1JJ00 1 1 unit 41B
3RH2 48 ... 127 24 ... 70 20 ... 470 3RT2916-1JK00 1 1 unit 41B
127 ... 240 70 ... 150 50 ... 700 3RT2916-1JL00 1 1 unit 41B
-- 150 ... 250 160 ... 950 3RT2916-1JP00 1 1 unit 41B
3RT2916-1J.00 3RT2.1, Interference -- 24 ... 70 20 ... 470 3RT2916-1LM00 1 1 unit 41B
3RH2 suppression -- 50 ... 150 50 ... 700 3RT2916-1LN00 1 1 unit 41B
diodes -- 150 ... 250 160 ... 950 3RT2916-1LP00 1 1 unit 41B
Size S0
For plugging into the front of the contactors
(before mounting the auxiliary switch)
3RT2.2 Varistors 24 ... 48 12 ... 24 10 ... 120 3RT2926-1JJ00 1 1 unit 41B
48 ... 127 24 ... 70 20 ... 470 3RT2926-1JK00 1 1 unit 41B
127 ... 240 70 ... 150 50 ... 700 3RT2926-1JL00 1 1 unit 41B
3RT2.2 Diode -- 24 20 ... 470 3RT2926-1MR00 1 1 unit 41B
3RT2926-1MR00 assemblies
Sizes S2 and S3
For plugging into the front of the contactors
(before mounting the auxiliary switch)
3RT2.3, Varistors 24 ... 48 12 ... 24 10 ... 120 3RT2936-1JJ00 1 1 unit 41B
3RT2.4 48 ... 127 24 ... 70 20 ... 470 3RT2936-1JK00 1 1 unit 41B
127 ... 240 70 ... 150 50 ... 700 3RT2936-1JL00 1 1 unit 41B

3RT2936-1JJ00
1)
Can be used for AC operation for 50/60 Hz. Other voltages on request.

* You can order this quantity or a multiple thereof.


3/98 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Modules for contactor control

■ Selection and ordering data


For contactors Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)
Type
Coupling links for control by PLC
Screw terminals

3
Size S0
For mounting on the coil terminals of the
contactors
(for contactors with screw terminals only)
With LED for the switching state and
with integrated varistor for damping switching
overvoltages
3RT2.2 • 24 V DC control, 3RH2924-1GP11 1 1 unit 41B
3RH2924-1GP11 17 ... 30 V DC operating range
Sizes S00 to S3
For mounting on the front of contactors
with AC, DC or AC/DC operation
3RT2.1, • 24 V DC control, 3RH2914-1GP11 1 1 unit 41B
3RT2.2, 17 ... 30 V DC operating range
3RT2.3,
3RT2.4
3RH2
3RH2914-1GP11 Spring-loaded terminals

3RT2.1, • 24 V DC control, 3RH2914-2GP11 1 1 unit 41B


3RT2.2, 17 ... 30 V DC operating range
3RT2.3,
3RT2.4
3RH2

3RH2914-2GP11
Technical specifications, see page 3/78.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/99
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Modules for contactor control
PU (UNIT, SET, M) = 1
PS* = 1 unit More information
PG = 41B Equipment Manual for 3RA28 function modules, see
https://support.industry.siemens.com/cs/ww/en/view/60279150
3

3RA2811-2CW10 3RA2812-1DW10 3RA2816-0EW20

For Size Version Rated control Time Screw terminals Spring-loaded terminals
contactors supply setting
voltage Us1) range t
Article No. Price Article No. Price
Type V AC/DC s per PU per PU
3RA28 function modules for mounting on 3RT2 contactors and
3RH2 contactor relays
For direct-on-line starting
3RT2.12), S00, S0 ON-delay 24 ... 240 0.05 ... 100 3RA2811-1CW10 3RA2811-2CW10
3RT2.22), two-wire design, (1, 10, 100;
3RH212), varistor integrated selectable)
3RH24 The electrical connection
3RT2.32), S2, S3 between the function 24 ... 90 0.05 ... 100 3RA2831-1DG10 3RA2831-2DG10
3RT2.42)3) module and the contactor 90 ... 240 (1, 10, 100; 3RA2831-1DH10 3RA2831-2DH10
underneath is established selectable)
automatically when it is
snapped on and locked.
3RT2.12), S00, S0 OFF-delay 24 ... 240 0.05 ... 100 3RA2812-1DW10 3RA2812-2DW10
3RT2.22), with control signal, (1, 10, 100;
3RH212), varistor integrated selectable)
3RH24 The electrical connection
3RT2.32), S2, S3 between the function 24 ... 90 0.05 ... 100 3RA2832-1DG10 3RA2832-2DG10
3RT2.42)3) module and the contactor 90 ... 240 (1, 10, 100; 3RA2832-1DH10 3RA2832-2DH10
underneath is established selectable)
automatically when it is
snapped on and locked.
For star-delta (wye-delta) starting
3RT2.1, S00 ... S3 Varistor integrated 24 ... 240 0.5 ... 60 3RA2816-0EW20 3RA2816-0EW20
3RT2.2, Comprising one basic (10, 30, 60;
3RT2.32), module and two coupling selectable)
3RT2.42)4) modules
The electrical connection
between the function
module and the contactor
assembly is established
automatically by snapping
on and plugging in the
connecting cables.
Accessories
3RA28 S00 ... S3 Cover, sealable 3RA2910-0 3RA2910-0

1)
AC voltage values apply for 50 and 60 Hz. Assembly of reversing starters
2)
Cannot be fitted onto coupling relays and coupling contactor relays.
3) From product version E03 onwards, 3RA283. function modules can be We offer ready-made wiring kits for the assembly of reversing
used for 3RT2.4 contactors.
starters. Use of these wiring kits offers further advantages,
4) see page 3/148.
From product version E04 onwards, 3RA2816 function modules can be
used for 3RT2.4 contactors.
Technical specifications, see page 3/79.

* You can order this quantity or a multiple thereof.


3/100 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Modules for contactor control
PU (UNIT, SET, M) = 1
PS* = 1 unit More information
PG = 41B Equipment Manual for 3RA2711 function modules for IO-Link, see
https://support.industry.siemens.com/cs/ww/en/view/39319600
Equipment Manual for 3RA2712 function modules for AS-Interface, see
https://support.industry.siemens.com/cs/ww/en/view/39318922

3
3RA2711-1AA00 3RA2711-2AA00 3RA2711-1BA00 3RA2712-1CA00 3RA2711-2BA00 3RA2711-2CA00

For con- Size Version Screw terminals Spring-loaded terminals


tactors
Article No. Price Article No. Price
Type per PU per PU
SIRIUS 3RA27 function modules for direct-on-line starting
3RT201 S00 IO-Link connection 3RA2711-1AA00 3RA2711-2AA00
... ... Includes one module connector for creating an IO-Link group
3RT2041) S3 AS-Interface integration 3RA2712-1AA00 3RA2712-2AA00
SIRIUS 3RA27 function modules for reversing starting2)
3RT201 S00 IO-Link connection 3RA2711-1BA00 3RA2711-2BA00
... ... Comprising one basic and one coupling module and an
3RT2041) S3 additional module connector3) for creating an IO-Link group
AS-Interface integration 3RA2712-1BA00 3RA2712-2BA00
Comprising one basic and one coupling module
Assembly kits for making 3-pole contactor assemblies
See page 3/104
SIRIUS 3RA27 function modules for star-delta (wye-delta) starting4)
3RT201 S00 IO-Link connection 3RA2711-1CA00 3RA2711-2CA00
... ... Comprising one basic and two coupling modules and an
3RT2041) S3 additional module connector3) for creating an IO-Link group
AS-Interface integration 3RA2712-1CA00 3RA2712-2CA00
Comprising one basic and two coupling modules
Assembly kits for making 3-pole contactor assemblies
See page 3/105
1)
From product version E06 onwards, 3RA271. function modules can be Technical specifications for 3RA27 function modules,
used for 3RT2.4 contactors. see page 3/80.
2) For prewired reversing contactor assemblies with voltage tap-off,
see pages 3/149 to 3/152. When these contactor assemblies are used, For contactors with voltage tap-off, see pages 3/53, 3/57, 3/61
the assembly kit for the wiring is already integrated. and 3/63.
3)
3RA2711-0EE17 module connectors for size S3 must be ordered
separately, see page 3/102. For IO-Link masters and AS-Interface masters, routers and
4) power supply units, see "Industrial communication", page 2/1
For complete contactor assemblies for star-delta (wye-delta) starting
including function modules, see pages 3/167 to 3/170. onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/101
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Modules for contactor control

3RA2711-0EE10 3RA2711-0EE06 3RA2711-0EE15 3RA2910-0 3RA2711-0EE11 3RA6935-0A

For function Version Article No. Price PU PS* PG


modules per PU (UNIT,
SET, M)
3

Type
Accessories for 3RA27 function modules
3RA271.-..A00 Module connector set 3RA2711-0EE10 1 1 unit 41B
Comprising:
• Two module connectors (14-pole, short)
• Two interface covers
3RA271.-..A00 Module connectors
• 14-pole
- 6 cm 3RA2711-0EE17 1 1 unit 41B
- 9 cm 3RA2711-0EE06 1 1 unit 41B
- 13 cm 3RA2711-0EE18 1 1 unit 41B
- 26 cm 3RA2711-0EE07 1 1 unit 41B
- 33.5 cm 3RA2711-0EE08 1 1 unit 41B
• 10-pole, 9 cm 3RA2711-0EE16 1 1 unit 41B
for the additional auxiliary voltage infeed
Note:
Selection of module connectors, see Equipment Manual for 3RA2711
function modules for IO-Link.
3RA271.-..A00 Interface covers 3RA2711-0EE15 1 1 unit 41B
(set of 5)
3RA271.-..A00 Cover, sealable 3RA2910-0 1 5 units 41B
Operator panel for communication via IO-Link
3RA2711-..A00 Operator panel (set) 3RA6935-0A 1 1 unit 42F
Comprising:
• 1 x operator panel
• 1 x enabling module
• 1 x interface cover
• 1 x fixing terminal
3RA2711-..A00 Connecting cable 3RA2711-0EE11 1 1 unit 41B
For connecting the operator panel to the coupling module
Length 2 m, 10- to 14-pole
3RA2711-..A00 Enabling modules (replacement) 3RA6936-0A 1 1 unit 42F
3RA2711-..A00 Interface covers (replacement) 3RA6936-0B 1 5 units 42F

* You can order this quantity or a multiple thereof.


3/102 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Modules for contactor control

For contactors Rated control supply Time setting Screw terminals PU PS* PG
voltage Us range t (UNIT,
SET, M)
Article No. Price
Type V s per PU
Mechanical latching blocks
(no switching state change in the event of voltage drop)
Size S0
For snapping onto the front of contactors

3
The contactor remains in the energized state in the event of voltage
drop.
3RT202, 24 AC/DC -- 3RT2926-3AB31 1 1 unit 41B
3RT232, 110 AC/DC -- 3RT2926-3AF31 1 1 unit 41B
3RT252
230 AC/DC -- 3RT2926-3AP31 1 1 unit 41B

3RT2926-3A.31
OFF-delay devices for contactors with AC/DC and DC operation
Sizes S00 to S3
Non-adjustable delay time
3RT201.-1BF4., 110 AC/DC S00: > 0.1 3RT2916-2BK01 1 1 unit 41B
3RT202.-1BF4., S0: > 0.08
3RT203.-1NF3., S2: > 0.25
3RH2...-1BF40
3RT201.-1BM4./-1BP4., 220/230 AC/DC S00: > 0.5 3RT2916-2BL01 1 1 unit 41B
3RT202.-1BM4./-1BP4., S0: > 0.3
3RT203.-1NP3., S2: > 0.8
3RH2...-1BM40/-1BP40
3RT2916-2B.01 3RT201.-1BB4., 24 DC S00: > 0.2 3RT2916-2BE01 1 1 unit 41B
3RT202.-1BB4., S0: > 0.1
3RT203.-1NB3., S2: > 0.1
3RT204.-1NB3.,
3RT244.-1NB3., S3: > 0.05
3RH2...-1BB40

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/103
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Link modules

■ Selection and ordering data


For Size Version Article No. Price PU PS* PG
contactors per PU (UNIT,
SET, M)
Type
Safety main circuit connectors for two contactors
3RT2.1 S00 For series connection of two contactors 3RA2916-1A 1 1 unit 41B
3RT2.2 S0 3RA2926-1A 1 1 unit 41B
3

3RT2.3 S2 3RA2936-1A 1 1 unit 41B

3RA2926-1A

PU (UNIT, SET, M) = 1
PS* = 1 unit (unless otherwise specified)
PG = 41B
For con- Size Version Article No. Price Article No. Price
tactors per PU per PU
Type
Assembly kits for reversing contactor assemblies
for making 3-pole contactor assemblies
Screw terminals Spring-loaded terminals

3RT201 S00-S00 The assembly kit contains:


Mechanical interlock,
two connecting clips for two contactors,
3RA2923-2AA1 wiring modules on the top and bottom
• For main, auxiliary and control circuits 3RA2913-2AA1 3RA2913-2AA2
3RT202 S0-S0 The assembly kit contains:
Mechanical interlock,
two connecting clips for two contactors,
wiring modules on the top and bottom
3RA2923-2AA2
• For main, auxiliary and control 3RA2923-2AA1 --
circuits1)
• Only for main circuit2) -- 3RA2923-2AA2
3RT203 S2-S2 The assembly kit contains:
Two connectors for two contactors,
wiring modules on the top and bottom
3RA2933-2AA1 (3RA2934-2B mechanical interlock
must be ordered separately,
see page 3/108)
• For main and auxiliary circuits 3RA2933-2AA1 --
• Only for main circuit3) -- 3RA2933-2AA2
3RT204 S3-S3 The assembly kit contains:
Two connectors for two contactors,
3RA2943-2AA1 wiring modules on the top and bottom
(3RA2934-2B mechanical interlock
must be ordered separately,
see page 3/108)
• For main and auxiliary circuits 3RA2943-2AA1 --
• Only for main circuit3) -- 3RA2943-2AA2
3RT1.5 S6-S6 The assembly kit contains: 3RA1953-2A 3RA1953-2A
3RA2943-2AA2
3RT1.6 S10-S10 Wiring modules on the top 3RA1963-2A 3RA1963-2A
and bottom
3RT1.7 S12-S12 3RA1973-2A 3RA1973-2A

3RA1953-2A

3RA1963-2A
1) 2)
Use of the 3RA2923-2AA1 assembly kit in conjunction with the Version in size S0 with spring-loaded terminals:
3RT202.-.....-3MA0 contactors is limited because the auxiliary switches Only the wiring modules for the main circuit are included.
in the basic unit are not allowed to be used on account of the permanently No connecting clips are included for the auxiliary and control circuit.
mounted auxiliary switch. 3)
Version in sizes S2 and S3 with spring-loaded terminals in the auxiliary and
control circuits: Only the wiring modules for the main circuit are included.
A cable set is included for the auxiliary circuit.

* You can order this quantity or a multiple thereof.


3/104 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Link modules
PU (UNIT, SET, M) = 1
PS* = 1 unit (unless otherwise specified)
PG = 41B

3
3RA2913-2BB1 3RA2923-2BB1 3RA2923-2BB2 3RA2933-2BB1 3RA2943-2C 3RA2943-2BB2

For con- Size Version Screw terminals Spring-loaded terminals


tactors
Article No. Price Article No. Price
Type per PU per PU
Assembly kits1) for contactor assemblies for star-delta (wye-delta)
starting for making 3-pole contactor assemblies
3RT201 S00-S00-S00 The assembly kit contains:
Mechanical interlock, four connecting clips for three
contactors, a star jumper, wiring modules on the top
and bottom
• For main, auxiliary and control circuits 3RA2913-2BB1 3RA2913-2BB2
3RT202 S0-S0-S0 The assembly kit contains:
Mechanical interlock, four connecting clips for three
contactors, a star jumper, wiring modules on the top
and bottom
• For main, auxiliary and control circuits 3RA2923-2BB1 --
• Only for main circuit -- 3RA2923-2BB2
3RT202 S0-S0-S0 The assembly kit contains:
Mechanical interlock, four connecting clips for three
contactors, a star jumper, wiring modules on the top
and bottom, 3-phase infeed terminal
• For main, auxiliary and control circuits 3RA2924-2BB1 --
3RT203 S2-S2-S0 The assembly kit2) contains: 3RA2933-2C 3RA2933-2C
Two connectors for three contactors, an S0 star
jumper, a spacer, wiring modules on the top and
bottom (S2-S0) for the main circuit, a cable set for
the auxiliary circuit, a cable for connecting the
A2 coil contact of the line contactor to the A2 coil
contact of the delta contactor
3RT203 S2-S2-S2 The assembly kit2) contains:
Four connectors for three contactors, an S2 star
jumper, a cable for connecting the A2 coil contact of
the line contactor to the A2 coil contact of the delta
contactor and
• Wiring modules on the top and bottom for the main 3RA2933-2BB1 --
circuit and the auxiliary circuit
• Wiring modules on the top and bottom for the main -- 3RA2933-2BB2
circuit, a cable set for the auxiliary circuit
3RT204 S3-S3-S2 The assembly kit2)contains: 3RA2943-2C 3RA2943-2C
Two connectors for three contactors, an S2 star
jumper, a spacer, wiring modules on the top and
bottom (S3-S2) for the main circuit, a cable set for
the auxiliary circuit, a cable for connecting the
A2 coil contact of the line contactor to the A2 coil
contact of the delta contactor
3RT204 S3-S3-S3 The assembly kit2) contains:
Four connectors for three contactors, an S3 star
jumper, a cable for connecting the A2 coil contact of
the line contactor to the A2 coil contact of the delta
contactor and
• Wiring modules on the top and bottom for the main 3RA2943-2BB1 --
circuit and the auxiliary circuit
• Wiring modules on the top and bottom for the main -- 3RA2943-2BB2
circuit, a cable set for the auxiliary circuit
1) When using the function modules for contactor assemblies for star-delta 2) The 3RA2934-2B mechanical interlock for sizes S2 and S3 must be
(wye-delta) starting, the wiring modules for the auxiliary current are not ordered separately, see page 3/108.
required.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/105
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Link modules

For Size Version Article No. Price PU PS* PG


contactors per PU (UNIT,
SET, M)
Type
Assembly kits for contactor assemblies for star-delta (wye-delta)
starting for making 3-pole contactor assemblies
The assembly kit contains:
link rails at bottom (a double
infeed between the line
3

contactor and the delta


contactor is
recommended.)
3RT1.5, S6-S6-S3 The S3 star jumper must be 3RA1953-3G 1 1 unit 41B
3RT204 For ordered separately,
connection see page 3/107.
with box
3RA1953-3G terminal only
3RT1.5 S6-S6-S6 -- 3RA1953-2B 1 1 unit 41B
For
connection
with box
terminal only

3RA1953-2B
3RT1.5 S6-S6-S6 -- 3RA1953-2N 1 1 unit 41B
For
connection
without box
terminal

3RA1953-2N
3RT1.6, S10-S10-S6 The S6 star jumper must be 3RA1963-3E 1 1 unit 41B
3RT1.5 For ordered separately,
connection see page 3/107.
with box
3RA1963-3E terminal only
3RT1.6 S10-S10-S10 -- 3RA1963-2B 1 1 unit 41B
For
connection
without box
terminal

3RA1963-2B
3RT1.7, S12-S12-S10 The S10 star jumper must 3RA1973-3E 1 1 unit 41B
3RT1.6 For be ordered separately,
connection see page 3/107.
with box
terminal only
3RA1973-3E
3RT1.7 S12-S12-S12 -- 3RA1973-2B 1 1 unit 41B
For
connection
without box
terminal

3RA1973-2B

* You can order this quantity or a multiple thereof.


3/106 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Link modules
PU (UNIT, SET, M) = 1
PS* = 1 unit (unless otherwise specified)
PG = 41B
For con- Size Version Article No. Price Article No. Price
tactors per PU per PU
Type
Single wiring modules
for making 3-pole contactor assemblies

3
Screw terminals Spring-loaded terminals

3RT201 S00-S00 • Top (in-phase) PS = 3RA2913-3DA1 3RA2913-3DA2


5 units
• Bottom PS = 3RA2913-3EA1 3RA2913-3EA2
3RA2913-3DA1 (with phase reversal) 5 units
3RT202 S0-S0 • Top (in-phase) PS = 3RA2923-3DA1 3RA2923-3DA2
5 units
• Bottom PS = 3RA2923-3EA1 3RA2923-3EA2
3RA2923-3DA1 (with phase reversal) 5 units
3RT203 S2-S2 • Top (in-phase), 3RA1933-3D 3RA1933-3D
contactor clearance
10 mm
• Bottom (with phase 3RA1933-3E 3RA1933-3E
3RA1933-3D
reversal), contactor
clearance 10 mm
3RT204 S3-S3 • Top (in-phase), 3RA1943-3D 3RA1943-3D
contactor clearance
10 mm
• Bottom (with phase 3RA1943-3E 3RA1943-3E
3RA1943-3E reversal), contactor
clearance 10 mm
3RT1.5 S6-S6 • Top (in-phase, 3RA1953-3D 3RA1953-3D
for connection with box
terminal), contactor
clearance 10 mm
3RA1953-3D • Top (with phase 3RA1953-3P 3RA1953-3P
reversal, for connection
without box terminal),
contactor clearance
10 mm
Star jumpers (links for paralleling), 3-pole
Screw terminals Spring-loaded terminals

3RT201 S00 With through-hole 3RT1916-4BA31 3RT2916-4BA32


The links for paralleling
can be reduced by one
pole.
3RT1916-4BA31
Without connecting
3RT202 S0 terminal 3RT1926-4BA31 3RT2926-4BA32

3RT2926-4BA32
3RT203 S2 3RT1936-4BA31 3RT1936-4BA31

3RT1936-4BA31
3RT204 S3 3RT1946-4BA31 3RT1946-4BA31

3RT1946-4BA31
3RT1.5 S6 3RT1956-4BA31 3RT1956-4BA31

3RT1956-4BA31
3RT1.6, S10, 3RT1966-4BA31 3RT1966-4BA31
3RT1.7 S12

3RT1966-4BA31

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/107
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Link modules

For con- Size Version Article No. Price PU PS* PG


tactors per PU (UNIT,
SET, M)
Type
Mechanical interlock assembly kits for two contactors
for making 3- and 4-pole contactor assemblies
3RT201, S00-S00 The interlocking assembly kits can be used 3RA2912-2H 1 10 units 41B
3RT231 without a contactor clearance.
3

3RT202, S0-S0 One assembly kit consists of a mechanical 3RA2922-2H 1 10 units 41B
3RT232 interlock and two connecting clips.
3RA2922-2H

For con- Size Version Article No. Price PU PS* PG


tactors per PU (UNIT,
SET, M)
Type
Mechanical interlocks for contactor assemblies
A contactor clearance of 10 mm must be
considered when using the following
mechanical interlocks.
3RT202, S2-S2, Mechanical interlocks 3RA2934-2B 1 1 unit 41B
3RT203 S3-S3 Note:
3RT202, S2-S2-S0, The mechanical interlock for sizes S2
3RT203, S2-S2-S2, and S3 must be ordered separately.
3RT204 S3-S3-S2,
S3-S3-S3

3RA2934-2B
3RT1.5 S6 (3RT1)- Adapter in addition to the mechanical 3RA1954-2G 1 1 unit 41B
with S6 (3RT1)- interlock
1)
3RT204 S3 (3RT2)1) The mechanical interlock is only possible
together with this 3RA1954-2G adapter
and the 3RA1954-2A mechanical
interlock.
Two connectors are included with the
adapter, the interlock must be ordered
3RA1954-2G separately.
3RT1.5 S6 Mechanical interlocks 3RA1954-2A 1 1 unit 41B
3RT1.6 S10 Without auxiliary contacts;
3RT1.7 S12 contactors in sizes S6, S10 and S12 can
be interlocked with each other as
required. No adaption of mounting depth
3RA1954-2A is necessary.
Mechanical connectors for contactor assemblies
Two connectors are required for each
assembly. The contactor clearance must
be considered when selecting the
connectors.
3-pole version
3RT203, S2-S2, • Without contactor clearance 3RA2932-2C 1 10 units 41B
3RT204 S3-S3 • With 10 mm contactor clearance 3RA2932-2D 1 10 units 41B
3RA1932-2D
3RT105 S6-S6 • With 10 mm contactor clearance 3RA1932-2D 1 10 units 41B
(1 unit corresponds to 2 parts for
1 assembly)
4-pole version
3RT233 S2-S2 • With 20 mm contactor clearance 3RA2932-2G 1 10 units 41B
3RT234. S3-S3 • With 10 mm contactor clearance 3RA2942-2G 1 10 units 41B

3RA2942-2G
1) The 3RA1954-2G adapter cannot be used in conjunction with
3RT204..-.KB coupling contactors, size S3.

* You can order this quantity or a multiple thereof.


3/108 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Connection modules/adapters

■ Selection and ordering data


For con- Size Version Screw terminals PU PS* PG
tactors (UNIT,
SET, M)
Article No. Price
Type per PU
Links for paralleling for main conducting paths
The links for paralleling (insulated) can be reduced by

3
one pole. With connecting terminal
3-pole
3RT201 S00 • Max. conductor cross-section: 25 mm2, stranded 3RT1916-4BB31 1 1 unit 41B

3RT1916-4BB31
3RT202 S0 • Max. conductor cross-section: 50 mm2, stranded 3RT2926-4BB31 1 1 unit 41B

3RT2926-4BB31
3RT203 S2 • Max. conductor cross-section: 120 mm2, stranded 3RT1936-4BB31 1 1 unit 41B

3RT1936-4BB31
3RT204, S3 • Max. conductor cross-section: 185 mm2, stranded 3RT1946-4BB31 1 1 unit 41B
3RT244 A cover plate is included for touch protection
(can only be used when box terminal is removed).

3RT1946-4BB31
4-pole
3RT231, S00 • Max. conductor cross-section: 25 mm2, stranded 3RT1916-4BB41 1 1 unit 41B
3RT251

3RT1916-4BB41

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/109
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Connection modules/adapters

For con- Size Version Article No. Price PU PS* PG


tactors per PU (UNIT,
SET, M)
Type
1-phase infeed terminals
3RT204, S3 Conductor cross-section: 95 mm2 3RA2943-3L 1 1 unit 41B
3RT244,
3RT264
3

3RA2943-3L
3-phase infeed terminals
3RT201 S00 Max. conductor cross-section: 3RA2913-3K 1 10 units 41B
Up to 10 mm2, AWG 12 ... 8

3RA2913-3K
3RT202, S0 Max. conductor cross-section: 3RV2925-5AB 1 1 unit 41E
3RT262 Up to 25 mm2, AWG 10 ... 2/0

3RV2925-5AB
3RT203, S2 Max. conductor cross-section: 3RV2935-5A 1 1 unit 41E
3RT263 Up to 70 mm2, AWG 10 ... 2/0

3RV2935-5A
3-phase infeed terminals with increased clearance and creepage
distances
3RT203 S2 Max. conductor cross-section: 3RV2935-5E 1 1 unit 41E
Up to 70 mm2, AWG 10 ... 2/0

3RV2935-5E
3-phase busbars
3RT202 S0 Bridging phase-by-phase of all input 3RV1915-1AB 1 1 unit 41E
terminals of the line contactor (Q11)
and delta contactor (Q13)
3RV1915-1AB
Terminal blocks for connecting auxiliary conductors to main terminals
Box terminal blocks
For round and ribbon cables
(Connectable cross-sections of the
contactors for size S3, see page 3/40 and
for sizes 6 to S12, see page 3/44)
3RT204 S3 • 3-pole, for connection of main contacts, 3RT2946-4G 1 1 unit 41B
2.5 to 70 mm2

3RT2946-4G
3RT1.5 S6 • Up to 70 mm2, as standard on 3RT1955-4G 1 1 unit 41B
3RT1054-1 contactor (55 kW)
• Up to 120 mm2 3RT1956-4G 1 1 unit 41B

3RT1956-4G
3RT1.6, S10, • Up to 240 mm2, 3RT1966-4G 1 1 unit 41B
3RT1.7 S12 with auxiliary conductor connection up to
2.5 mm2

3RT1966-4G
3RT1.5 S6 Box terminal for auxiliary conductor 3TX7500-0A 1 1 unit 41B
connection, 1-pole
For connection of auxiliary and control
3TX7500-0A cables (0.5 ... 2.5 mm2) to the main
conductor terminals
3RT204 S3 Auxiliary conductor terminals, 3-pole 3RT2946-4F 1 1 unit 41B
For connection of auxiliary and control
cables (0.5 ... 2.5 mm2) to the main
3RT2946-4F conductor terminals

* You can order this quantity or a multiple thereof.


3/110 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Connection modules/adapters

For Size Version Article No. Price PU PS* PG


contactors per PU (UNIT,
SET, M)
Type
Solder pin adapters for mounting contactors on printed circuit boards up
to 5.5 kW/12 A
Screw terminals

3RT2.1, S00 Assembly kit for soldering contactors 3RT1916-4KA1 1 4 units 41B

3
3RH21 with an integrated auxiliary contact onto
a printed circuit board
Note:
One kit is required for one contactor.

3RT1916-4KA1
3RT2.1, S00 Assembly kit for soldering contactors 3RT1916-4KA2 1 4 units 41B
3RH21 with 4-pole mounted auxiliary switch
onto a printed circuit board
Note:
One kit is required for one contactor.

3RT1916-4KA2
Coil connection modules for connections from top or from below
3RT2.2, S0 to S3 • Connection from top 3RT2926-4RA11 1 1 unit 41B
3RT2.3, • Connection from below 3RT2926-4RB11 1 1 unit 41B
3RT2.4
• Connection diagonally 3RT2926-4RC11 1 1 unit 41B
Spring-loaded terminals
3RT2926-4RA11
3RT2.2 S0 • Connection from top 3RT2926-4RA12 1 1 unit 41B
• Connection from below 3RT2926-4RB12 1 1 unit 41B

3RT2926-4RA12

For Size Version Screw terminals PU PS* PG


contactors (UNIT,
SET, M)
Article No. Price
Type per PU
Connection module (adapter and plug) for contactors with screw terminals
The connection module comprises an
adapter and a motor feeder connector.
Adapters
Ambient temperature tu max. = 60 °C
3RT201, S00 • Rated operational current Ie at 3RT1916-4RD01 1 1 unit 41B
3RT1926-4RD01 3RH2 AC-3/AC-3e/400 V: 20 A
3RT202 S0 • Rated operational current Ie at 3RT1926-4RD01 1 1 unit 41B
AC-3/AC-3e/400 V: 25 A
3RT201, S00, S0 Motor feeder connector 3RT1900-4RE01 1 1 unit 41B
3RT202,
3RH2

3RT1900-4RE01

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/111
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Covers

■ Selection and ordering data


For con- Size Version Article No. Price PU PS* PG
tactors per PU (UNIT,
SET, M)
Type
Terminal covers
Covers for contactors with
screw terminals (box terminals)
3

(2 units required per contactor)


3RT203 S2 • For 3-pole contactors 3RT2936-4EA2 1 1 unit 41B
3RT204, S3 3RT2946-4EA2 1 1 unit 41B
3RT244
3RT2936-4EA2 3RT2946-4EA2
3RT1.5 S61) 3RT1956-4EA2 1 1 unit 41B
3RT1.6, S101), 3RT1966-4EA2 1 1 unit 41B
3RT1.7 S121)
3RT1956-4EA2 3RT1966-4EA2
3RT233, S2 • For 4-pole contactors 3RT2936-4EA4 1 1 unit 41B
3RT253 (Scope of supply:
3RT234, S3 one 3-pole and two 1-pole 3RT2946-4EA4 1 1 unit 41B
3RT254 terminal covers are supplied)

3RT2936-4EA4 3RT2946-4EA4
Covers for contactors with
cable lugs and busbar
connections
• For complying with the phase
clearances and as touch
protection if box terminal is
removed (2 units required per
contactor)
3RT1946-4EA1 3RT2.4 S3 - Length: 100 mm 3RT1946-4EA1 1 1 unit 41B
3RT1.5 S61) - Length: 100 mm 3RT1956-4EA1 1 1 unit 41B
3RT1.6, S101), - Length: 120 mm 3RT1966-4EA1 1 1 unit 41B
3RT1.7 S121)
• For the assembly kits for
3RA1953-.. contactor assemblies
3RT1956-4EA1 3RT1966-4EA1 for star-delta (wye-delta) starting
(see page 3/106) or for the
3RA1953-3 single wiring
modules. (see page 3/107)
3RT1956-4EA4 3RT1.5 S6 - Length: 38 mm 3RT1956-4EA4 1 1 unit 41B
• For the assembly kits for
reversing contactor assemblies
and contactor assemblies for
3RT1966-4EA3 star-delta (wye-delta) starting
3RT1.6, S10, - Length: 42 mm 3RT1966-4EA3 1 1 unit 41B
3RT1.7 S12
Terminal covers for busbar
connections
• Cover the three busbar
connections, between the
contactor and 3RB2 overload
3RT1956-4EA3 3RT1966-4EA3 relay
3RT1.5 S6 - Length: 27 mm 3RT1956-4EA3 1 1 unit 41B
3RT1.6, S10, - Length: 42 mm 3RT1966-4EA3 1 1 unit 41B
3RT1.7 S12
• Can be screwed on free screw
end; covers one busbar
connection (1 set = 6 units)
3RT1.5 S6 - M8 3TX6526-3B 1 1 unit 41B
3RT1.6, S10, - M10 3TX6546-3B 1 1 unit 41B
3RT1.7 S12
3TX6526-3B 3TX6546-3B
Sealable covers
3RT2.1, S00 ... For preventing manual 3RT2916-4MA10 1 5 units 41B
3RT2.2, S3 operation
3RT2.3, (Not suitable for coupling
3RT2.4, contactors)
3RH22)
3RT2916-4MA10 3RT1926-4MA10
3RT1.5 S6 ... 3RT1926-4MA10 1 5 units 41B
... S12
3RT1.72)
1) 2)
Also fits on contactors of sizes S6 to S12 with box terminals. Exception: Contactors and contactor relays with auxiliary switch mounted
on the front.
* You can order this quantity or a multiple thereof.
3/112 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Miscellaneous accessories

■ Selection and ordering data


For con- Size Version Article No. Price PU PS* PG
tactors per PU (UNIT,
SET, M)
Type
Base plates
For reversing contactor assemblies
3RT1.5 S6 For customer assembly of reversing 3RA1952-2A 1 1 unit 41B

3
3RT1.6 S10 contactor assemblies 3RA1962-2A 1 1 unit 41B
3RT1.7 S12 3RA1972-2A 1 1 unit 41B

3RA1952-2A
For contactor assemblies for star-delta (wye-delta) starting
3RT2/ S2-S2-S0, For configuring contactor assemblies 3RA2932-2F 1 1 unit 41B
3RT2/ S2-S2-S2 for star-delta (wye-delta) starting
3RT2 S3-S3-S2, 3RA2942-2F 1 1 unit 41B
S3-S3-S3

3RA2932-2F

3RA2942-2F
3RT1/ S6-S6-S3 For customer assembly of contactor 3RA1952-2E 1 1 unit 41B
3RT1/ assemblies for star-delta (wye-delta)
3RT2 starting with a laterally mounted
3RT1/ S6-S6-S6 timing relay 3RA1952-2F 1 1 unit 41B
3RT1/ S10-S10-S6 10 mm clearance between the 3RA1962-2E 1 1 unit 41B
3RT1 contactors
S10-S10-S10 3RA1962-2F 1 1 unit 41B
3RA1952-2E S12-S12-S10 3RA1972-2E 1 1 unit 41B
S12-S12-S12 3RA1972-2F 1 1 unit 41B

3RA1952-2F
Adapters for screw fixing
3RT2.2 S0 Screw adapters for securing the 3RT1926-4P 1 10 units 41B
contactors, two units required per
contactor
3RT1926-4P (1 pack = 10 sets for 10 contactors)

Connection kit for one complete contactor


Each set includes 6 screws, spring
washers and nuts.
3RT105 S6 M 8 x 25 3RT1955-4PA00 1 1 unit 41B
3RT106, S10, S12 M 10 x 30 3RT1966-4PA00 1 1 unit 41B
3RT107

3RT1955-4PA00
EMC suppression modules; 3-phase, up to 7.5 kW
For contactors with AC or DC operation
Screw terminals

3RT201 S00 RC elements (3 x 220 /0.22 µF)


• Up to 400 V 3RT2916-1PA1 1 1 unit 41B
• Up to 575 V 3RT2916-1PA2 1 1 unit 41B
• Up to 690 V 3RT2916-1PA3 1 1 unit 41B
3RT201 S00 Varistors
• Up to 400 V 3RT2916-1PB1 1 1 unit 41B
3RT2916-1PA. • Up to 575 V 3RT2916-1PB2 1 1 unit 41B
• Up to 690 V 3RT2916-1PB3 1 1 unit 41B

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/113
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Miscellaneous accessories

For con- Size Version Article No. Price PU PS* PG


tactors per PU (UNIT,
SET, M)
Type
Additional load modules
3RT2.1, S00 For plugging onto the front of the 3RT2916-1GA00 1 1 unit 41B
3RH2 contactors with or without auxiliary
switches
For increasing the permissible
3

residual current and for limiting the


residual voltage,
it ensures the safe opening of
contactors with direct control via
230 V AC semiconductor outputs of
SIMATIC controllers,
3RT2916-1GA00 simultaneously provides overvoltage
damping
Rated voltage:
50/60 Hz AC, 180 ... 255 V
Operating range: 0.8 ... 1.1 x Us
LED modules for displaying contactor operation
3RT2, S00 ... S12 For snapping into the location hole of 3RT2926-1QT00 1 5 units 41B
3RT1 an inscription label on the front of
a contactor either directly on the
contactor or on the front auxiliary
switch.
The LED module is connected to coil
terminals A1 and A2 of the contactor
and indicates its energized state with
a yellow LED. Connecting leads
3RT2926-1QT00 need to be extended as required.
Rated voltage:
24 ... 240 V AC/DC with reverse
polarity protection
Control kit
3RT2.1, S00 For manual operation of contactor 3RT2916-4MC00 1 5 units 41B
3RH2 contacts, for startup and service
3RT2.2 S0 3RT2926-4MC00 1 5 units 41B
3RT2.3, S2, S3 3RT2936-4MC00 1 5 units 41B
3RT2.4
3RT2916-4MC00

* You can order this quantity or a multiple thereof.


3/114 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Miscellaneous accessories

For con- Size Version Article No. Price PU PS* PG


tactors per PU (UNIT,
SET, M)
Type
Insulation stop for securely holding back the conductor insulation
for conductors up to 1 mm2
Spring-loaded terminals

Insulation stop strip

3
Can be inserted in cable entry of the
spring-loaded terminal (two strips per
3RT2916-4JA02 contactor required)
3RT2.1, S00 • For basic units, removable individually 3RT2916-4JA02 1 20 units 41B
3RH2
3RT2.2 S0 ... S12 • For auxiliary and control current on 3RT1916-4JA02 1 20 units 41B
3RT1916-4JA02 ... basic units and for mountable 3RH29
3RT2.4, auxiliary switches, removable in pairs
3RT1,
3RH29
Tools for opening spring-loaded terminals
3RT, S00 ... S12 Screwdrivers 3RA2908-1A 1 1 unit 41B
3RH For all SIRIUS devices with
spring-loaded terminals
Length: approx. 200 mm,
3.0 mm x 0.5 mm,
titanium gray/black,
3RA2908-1A
partially insulated
Blank labels
Unit labeling plates1)
For SIRIUS devices
3RT S00 ... S12 • 10 mm x 7 mm, titanium gray 3RT2900-1SB10 100 816 units 41B
• 20 mm x 7 mm, titanium gray 3RT2900-1SB20 100 340 units 41B
IC01_00181

Adhesive labels
For SIRIUS devices
3RT S00 ... S12 • 19 mm x 6 mm, titanium gray 3RT2900-1SB60 100 3060 units 41B
3RT2900-1SB20
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/115
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Spare parts for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Solenoid coils

■ Selection and ordering data


Screw terminals and spring-loaded terminals
3

3RT2924-5A.01
For contactors Rated control supply voltage Us Article No. Price PU PS* PG
50 Hz 50/60 Hz 60 Hz per PU (UNIT,
SET, M)
Type V V V
Solenoid coils  AC operation
Size S0
3RT2023-.A, 24 -- -- 3RT2924-5AB01 1 1 unit 41B
3RT2024-.A, 42 -- -- 3RT2924-5AD01 1 1 unit 41B
3RT2025-.A 48 -- -- 3RT2924-5AH01 1 1 unit 41B
110 -- -- 3RT2924-5AF01 1 1 unit 41B
230 -- -- 3RT2924-5AP01 1 1 unit 41B
400 -- -- 3RT2924-5AV01 1 1 unit 41B
-- 24 -- 3RT2924-5AC21 1 1 unit 41B
-- 42 -- 3RT2924-5AD21 1 1 unit 41B
-- 48 -- 3RT2924-5AH21 1 1 unit 41B
-- 110 -- 3RT2924-5AG21 1 1 unit 41B
-- 220 -- 3RT2924-5AN21 1 1 unit 41B
-- 230 -- 3RT2924-5AL21 1 1 unit 41B
-- -- 24 3RT2924-5AC11 1 1 unit 41B
110 -- 120 3RT2924-5AK61 1 1 unit 41B
220 -- 240 3RT2924-5AP61 1 1 unit 41B
-- 100 110 3RT2924-5AG61 1 1 unit 41B
-- 200 220 3RT2924-5AN61 1 1 unit 41B
-- 400 440 3RT2924-5AR61 1 1 unit 41B
3RT2026-.A, 24 -- -- 3RT2926-5AB01 1 1 unit 41B
3RT2027-.A, 42 -- -- 3RT2926-5AD01 1 1 unit 41B
3RT2028-.A 48 -- -- 3RT2926-5AH01 1 1 unit 41B
3RT2325-.A, 110 -- -- 3RT2926-5AF01 1 1 unit 41B
3RT2326-.A, 230 -- -- 3RT2926-5AP01 1 1 unit 41B
3RT2327-.A 400 -- -- 3RT2926-5AV01 1 1 unit 41B
3RT2526-.A
-- 24 -- 3RT2926-5AC21 1 1 unit 41B
-- 42 -- 3RT2926-5AD21 1 1 unit 41B
-- 48 -- 3RT2926-5AH21 1 1 unit 41B
-- 110 -- 3RT2926-5AG21 1 1 unit 41B
-- 220 -- 3RT2926-5AN21 1 1 unit 41B
-- 230 -- 3RT2926-5AL21 1 1 unit 41B
-- -- 24 3RT2926-5AC11 1 1 unit 41B
110 -- 120 3RT2926-5AK61 1 1 unit 41B
220 -- 240 3RT2926-5AP61 1 1 unit 41B
-- 100 110 3RT2926-5AG61 1 1 unit 41B
-- 200 220 3RT2926-5AN61 1 1 unit 41B
-- 400 440 3RT2926-5AR61 1 1 unit 41B

Note:
Contactors with AC and AC/DC coils have different depths. It is
only possible to replace the coils on AC contactors with AC coils.
It is not possible to replace the coils on DC contactors.

* You can order this quantity or a multiple thereof.


3/116 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Spare parts for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Solenoid coils
Screw terminals and spring-loaded terminals

3
3RT2934-5A.01 3RT2934-5N.31 3RT2944-5A..1 3RT2944-5N.31
For contactors Rated control supply voltage Us Article No. Price PU PS* PG
50 Hz 50/60 Hz 60 Hz DC per PU (UNIT,
SET, M)
Type V V V
Solenoid coils  AC operation
Size S2
3RT203.-.A, 24 -- -- -- 3RT2934-5AB01 1 1 unit 41B
3RT233.-.A, 42 -- -- -- 3RT2934-5AD01 1 1 unit 41B
3RT243.-.A, 48 -- -- -- 3RT2934-5AH01 1 1 unit 41B
3RT253.-.A 110 -- -- -- 3RT2934-5AF01 1 1 unit 41B
230 -- -- -- 3RT2934-5AP01 1 1 unit 41B
400 -- -- -- 3RT2934-5AV01 1 1 unit 41B
-- 24 -- -- 3RT2934-5AC21 1 1 unit 41B
-- 42 -- -- 3RT2934-5AD21 1 1 unit 41B
-- 48 -- -- 3RT2934-5AH21 1 1 unit 41B
-- 110 -- -- 3RT2934-5AG21 1 1 unit 41B
-- 208 -- -- 3RT2934-5AM21 1 1 unit 41B
-- 220 -- -- 3RT2934-5AN21 1 1 unit 41B
-- 230 -- -- 3RT2934-5AL21 1 1 unit 41B
110 -- 120 -- 3RT2934-5AK61 1 1 unit 41B
220 -- 240 -- 3RT2934-5AP61 1 1 unit 41B
-- -- 480 -- 3RT2934-5AV61 1 1 unit 41B
-- -- 600 -- 3RT2934-5AT61 1 1 unit 41B
-- 100 110 -- 3RT2934-5AG61 1 1 unit 41B
-- 200 220 -- 3RT2934-5AN61 1 1 unit 41B
-- -- 277 -- 3RT2934-5AU61 1 1 unit 41B
-- 400 440 -- 3RT2934-5AR61 1 1 unit 41B
Size S3
3RT204.-.A, 24 -- -- -- 3RT2944-5AB01 1 1 unit 41B
3RT234.-.A, 42 -- -- -- 3RT2944-5AD01 1 1 unit 41B
3RT244.-.A, 48 -- -- -- 3RT2944-5AH01 1 1 unit 41B
3RT254.-.A 110 -- -- -- 3RT2944-5AF01 1 1 unit 41B
230 -- -- -- 3RT2944-5AP01 1 1 unit 41B
400 -- -- -- 3RT2944-5AV01 1 1 unit 41B
-- 24 -- -- 3RT2944-5AC21 1 1 unit 41B
-- 42 -- -- 3RT2944-5AD21 1 1 unit 41B
-- 48 -- -- 3RT2944-5AH21 1 1 unit 41B
-- 110 -- -- 3RT2944-5AG21 1 1 unit 41B
-- 220 -- -- 3RT2944-5AN21 1 1 unit 41B
-- 230 -- -- 3RT2944-5AL21 1 1 unit 41B
110 -- 120 -- 3RT2944-5AK61 1 1 unit 41B
220 -- 240 -- 3RT2944-5AP61 1 1 unit 41B
-- -- 480 -- 3RT2944-5AV61 1 1 unit 41B
-- -- 600 -- 3RT2944-5AT61 1 1 unit 41B
-- 100 110 -- 3RT2944-5AG61 1 1 unit 41B
-- 200 220 -- 3RT2944-5AN61 1 1 unit 41B
-- 400 440 -- 3RT2944-5AR61 1 1 unit 41B
Solenoid coils  AC/DC operation, with varistor
Size S2
3RT203.-.N, -- 20 ... 33 -- 20 ... 33 3RT2934-5NB31 1 1 unit 41B
3RT233.-.N -- 30 ... 42 -- 30 ... 42 3RT2934-5ND31 1 1 unit 41B
-- 48 ... 80 -- 48 ... 80 3RT2934-5NE31 1 1 unit 41B
-- 83 ... 155 -- 83 ... 155 3RT2934-5NF31 1 1 unit 41B
-- 175 ... 280 -- 175 ... 280 3RT2934-5NP31 1 1 unit 41B
Size S3
3RT204.-.N, -- 20 ... 33 -- 20 ... 33 3RT2944-5NB31 1 1 unit 41B
3RT234.-.N, -- 30 ... 42 -- 30 ... 42 3RT2944-5ND31 1 1 unit 41B
3RT244.-.N, -- 48 ... 80 -- 48 ... 80 3RT2944-5NE31 1 1 unit 41B
3RT254.-.N -- 83 ... 155 -- 83 ... 155 3RT2944-5NF31 1 1 unit 41B
-- 175 ... 280 -- 175 ... 280 3RT2944-5NP31 1 1 unit 41B

Notes:
It is only possible to replace the coils on AC contactors with Coil replacement is not permitted for 3RT20..-.S contactors with
AC coils, and on AC/DC contactors with AC/DC coils. fail-safe control.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/117
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Spare parts for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Solenoid coils
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
For contactors Rated control Screw terminals Spring-loaded terminals
supply voltage
Us Article No. Price Article No. Price
Size Type V per PU per PU
Withdrawable coils
Standard operating mechanism for AC/DC
3

S6 3RT105, 23 ... 26 AC/DC 3RT1955-5AB31 3RT1955-5AB32


3RT145 42 ... 48 AC/DC 3RT1955-5AD31 3RT1955-5AD32
110 ... 127 AC/DC 3RT1955-5AF31 3RT1955-5AF32
200 ... 220 AC/DC 3RT1955-5AM31 3RT1955-5AM32
220 ... 240 AC/DC 3RT1955-5AP31 3RT1955-5AP32
240 ... 277 AC/DC 3RT1955-5AU31 3RT1955-5AU32
380 ... 420 AC/DC 3RT1955-5AV31 3RT1955-5AV32
440 ... 480 AC/DC 3RT1955-5AR31 3RT1955-5AR32
500 ... 550 AC/DC 3RT1955-5AS31 3RT1955-5AS32
3RT1955-5A.31 575 ... 600 AC/DC 3RT1955-5AT31 3RT1955-5AT32
S10 3RT106, 23 ... 26 AC/DC 3RT1965-5AB31 3RT1965-5AB32
3RT146 42 ... 48 AC/DC 3RT1965-5AD31 3RT1965-5AD32
110 ... 127 AC/DC 3RT1965-5AF31 3RT1965-5AF32
200 ... 220 AC/DC 3RT1965-5AM31 3RT1965-5AM32
220 ... 240 AC/DC 3RT1965-5AP31 3RT1965-5AP32
240 ... 277 AC/DC 3RT1965-5AU31 3RT1965-5AU32
380 ... 420 AC/DC 3RT1965-5AV31 3RT1965-5AV32
440 ... 480 AC/DC 3RT1965-5AR31 3RT1965-5AR32
500 ... 550 AC/DC 3RT1965-5AS31 3RT1965-5AS32
575 ... 600 AC/DC 3RT1965-5AT31 3RT1965-5AT32
3RT1955-5A.32
S12 3RT107, 23 ... 26 AC/DC 3RT1975-5AB31 3RT1975-5AB32
3RT147 42 ... 48 AC/DC 3RT1975-5AD31 3RT1975-5AD32
110 ... 127 AC/DC 3RT1975-5AF31 3RT1975-5AF32
200 ... 220 AC/DC 3RT1975-5AM31 3RT1975-5AM32
220 ... 240 AC/DC 3RT1975-5AP31 3RT1975-5AP32
240 ... 277 AC/DC 3RT1975-5AU31 3RT1975-5AU32
380 ... 420 AC/DC 3RT1975-5AV31 3RT1975-5AV32
440 ... 480 AC/DC 3RT1975-5AR31 3RT1975-5AR32
500 ... 550 AC/DC 3RT1975-5AS31 3RT1975-5AS32
575 ... 600 AC/DC 3RT1975-5AT31 3RT1975-5AT32
Solid-state operating mechanism for AC/DC with 24 V DC control signal input
e.g. for control by PLC
S6 3RT105, 21 ... 27.3 AC/DC 3RT1955-5NB31 3RT1955-5NB32
3RT145 96 ... 127 AC/DC 3RT1955-5NF31 3RT1955-5NF32
200 ... 277 AC/DC 3RT1955-5NP31 3RT1955-5NP32
S10 3RT106, 21 ... 27.3 AC/DC 3RT1965-5NB31 3RT1965-5NB32
3RT146 96 ... 127 AC/DC 3RT1965-5NF31 3RT1965-5NF32
200 ... 277 AC/DC 3RT1965-5NP31 3RT1965-5NP32
S12 3RT107, 21 ... 27.3 AC/DC 3RT1975-5NB31 3RT1975-5NB32
3RT147 96 ... 127 AC/DC 3RT1975-5NF31 3RT1975-5NF32
3RT1955-5N.31
200 ... 277 AC/DC 3RT1975-5NP31 3RT1975-5NP32
• Additionally with PLC relay output and remaining
lifetime indicator (RLT)
(withdrawable coil with laterally mounted solid-state
module)
S6 3RT105, 96 ... 127 AC/DC 3RT1955-5PF31 --
3RT145 200 ... 277 AC/DC 3RT1955-5PP31 --
S10 3RT106, 96 ... 127 AC/DC 3RT1965-5PF31 --
3RT146 200 ... 277 AC/DC 3RT1965-5PP31 --
S12 3RT107, 96 ... 127 AC/DC 3RT1975-5PF31 --
3RT1955-5P.31 3RT147 200 ... 277 AC/DC 3RT1975-5PP31 --

Solid-state operating mechanism for DC with 24 ... 110 V DC control signal input
e.g. for control by PLC with extended application range
(see also contactors for railway applications, page 4/61 onwards)
S6 3RT105..-.X...-0LA2 24 DC -- 3RT1955-5XB42
72 DC -- 3RT1955-5XJ42
110 DC -- 3RT1955-5XF42
S10 3RT106..-.X...-0LA2 24 DC -- 3RT1965-5XB42
72 DC -- 3RT1965-5XJ42
110 DC -- 3RT1965-5XF42
3RT1955-5X.42 S12 3RT107..-.X...-0LA2 24 DC -- 3RT1975-5XB42
72 DC -- 3RT1975-5XJ42
110 DC -- 3RT1975-5XF42

Note:
In the case of 3RT10..-.S contactors with fail-safe control inputs,
removing and replacing the operating mechanism are not permitted.
* You can order this quantity or a multiple thereof.
3/118 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Spare parts for SIRIUS 3RT contactors and SIRIUS 3RH2 contactor relays > Contacts and arc chutes

■ Selection and ordering data


For contactors Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)
Size Type
Contacts with fixing parts
For contactors with 3 main contacts
S21) 3RT2035 Main contacts (3 NO contacts) for 3RT2935-6A 1 1 unit 41B

3
3RT2036 utilization category AC-3 and AC-3e 3RT2936-6A 1 1 unit 41B
3RT2037 (1 set = 3 movable and 6 fixed 3RT2937-6A 1 1 unit 41B
3RT2038 contacts with fixing parts) 3RT2938-6A 1 1 unit 41B
1)
S3 3RT2045 3RT2945-6A 1 1 unit 41B
3RT2046 3RT2946-6A 1 1 unit 41B
3RT2047 3RT2947-6A 1 1 unit 41B
3RT294.-6A S6 3RT1054 3RT1954-6A 1 1 unit 41B
3RT1055 3RT1955-6A 1 1 unit 41B
3RT1056 3RT1956-6A 1 1 unit 41B
S10 3RT1064 3RT1964-6A 1 1 unit 41B
3RT1065 3RT1965-6A 1 1 unit 41B
3RT1066 3RT1966-6A 1 1 unit 41B
S12 3RT1075 3RT1975-6A 1 1 unit 41B
3RT1076 3RT1976-6A 1 1 unit 41B
3RT1954-6A S3 3RT2446 Main contacts (3 NO contacts) for 3RT2946-6D 1 1 unit 41B
3RT2448 utilization category AC-1 3RT2948-6D 1 1 unit 41B
S6 3RT1456 (1 set = 3 movable and 6 fixed 3RT1956-6D 1 1 unit 41B
S10 3RT1466 contacts with fixing parts) 3RT1966-6D 1 1 unit 41B
3RT1467 3RT1967-6D 1 1 unit 41B
S12 3RT1476 3RT1976-6D 1 1 unit 41B

3RT197.-6A,
3RT1976-6D
For contactors with 4 main contacts
S2 3RT2336 Main contacts (4 NO contacts) for 3RT2936-6E 1 1 unit 41B
3RT2337 utilization category AC-1 3RT2937-6E 1 1 unit 41B
(1 set = 3 movable and 6 fixed
contacts and spare pole with fixing
parts)

3RT2936-6E
Arc chutes
For contactors with 3 main contacts
S6 3RT1054 Only for contactors with AC/DC coil 3RT1954-7A 1 1 unit 41B
3RT1055 3RT1955-7A 1 1 unit 41B
3RT1056 3RT1956-7A 1 1 unit 41B
3RT1456 3RT1956-7B 1 1 unit 41B

3RT195.-7.
S10 3RT1064 3RT1964-7A 1 1 unit 41B
3RT1065 3RT1965-7A 1 1 unit 41B
3RT1066 3RT1966-7A 1 1 unit 41B
3RT1466 3RT1966-7B 1 1 unit 41B

3RT196.-7.
S12 3RT1075 3RT1975-7A 1 1 unit 41B
3RT1076 3RT1976-7A 1 1 unit 41B
3RT1476 3RT1976-7B 1 1 unit 41B

3RT197.-7.
1)
Switching of the spare contact is not permitted for
3RT20..-.S contactors with fail-safe control.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/119
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors

■ Overview
If there are further switching elements in the circuit, such as the
auxiliary contact system of an overload relay that operates the
contactor, the short-circuit protection necessary for this must
also be considered.
For further recommendations, e.g. the use of miniature circuit
breakers or circuit breakers for equipment in control circuits, see
Control panel tip – Fast, reliable selection and dimensioning of
3

an appropriate power supply unit.


Protection of contactors with digital input from short circuit
and overload
For the PLC input types according to IEC 60947-4-1 these inputs
have a typical rated current of 20 mA.
These inputs can be protected accordingly (for 3RT12..-.N
contactors marked with IN+/IN-).
The supply voltage connections A1 - A2 must be protected
3RT12 and 3TF6 vacuum contactors according to the load characteristics.
Our power range of vacuum contactors for switching IE2 motors For information about power consumption, see the technical
and highly efficient IE3 and IE4 motors: product data sheet.
• Sizes S10 and S12: 3RT12 up to 250 kW Overvoltage protection at the control supply voltage connection
• Size 14: 3TF6 up to 450 kW The 3RT12 contactors are already equipped with coil damping
See from page 3/120 onwards (varistor).
Standards Note:
IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1 (auxiliary switches) The break times of the contactor, the opening delay times of the
NO contacts and the closing delay times of the NC contacts
Terminal covers may have to be fitted onto the connecting bars, increase with damping.
depending on the configuration with other devices (see
pages 3/112 and 3/134). For more detailed information about how damping affects the
time response, see Equipment Manual.
Operating conditions
Protection from overvoltage in the main circuit
Vacuum contactors are basically unsuitable for switching
DC voltage. Vacuum contactors are only approved for The 3RT12 and 3TF6 vacuum contactors can be retrofitted with
applications in the frequency range 45 to 60 Hz. Help with varistors for damping switching overvoltages in the coil.
applications > 60 Hz is available from our Technical Support, The 3TF6 contactors have integrated damping depending on
www.siemens.com/support-request. the version.
Protection of the device connections from short circuit, Note:
overload and overvoltage
When the 3TF6 contactors are used in an environment with
Appropriate steps must always be taken to protect device frequency converters, the overvoltage damping (if any)
connections from overload and short circuit. There are different must always be removed.
constraints depending on the type of connection:
For more information, see Equipment Manual.
Protection of main terminals from short circuit and overload
Connection methods
For information about protection of a single contactor,
see the technical product data sheet. Main circuit
For more information on complete units such as contactors with 3RT12 vacuum contactors are available with busbar connec-
overload relays or contactors with motor starter protectors as the tions. Box terminal blocks can be ordered separately as
motor feeder, see Configuration Manual for load feeders. accessories for versions with screw terminals, see page 3/134.
Protection of auxiliary connections from short circuit and overload The 3TF6 vacuum contactors are available with busbar
connections.
For information about protection of auxiliary contacts,
see the technical product data sheet. Auxiliary and control circuits
Protection of control supply voltage or supply voltage The 3RT12 and 3TF6 contactors are available with screw terminals.
connections from short circuit and overload Motor protection
First of all, the relevant standards and regulations for configuring For protection against overload, 3RB2 electronic overload relays
control panels and the parts and components installed in them (see page 7/114 onwards) can be mounted on the 3RT12
must be taken into account, for example when dimensioning vacuum contactors.
the cables.
One possible protection for these circuits could be the selection
of a suitable power supply, i.e. one with a current-limiting
function. In the selection of the source and the connecting cable,
the load characteristics of the contactor must be considered
(short-time inrush current peaks for solid-state contactor
operating mechanisms, closing, closed).

3/120 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors
Electromagnetic compatibility (EMC) Replacing operating mechanisms
The contactors satisfy the conditions for environment A 3RT12 vacuum contactors
according to IEC 60947-1.
The operating mechanisms of the vacuum contactors are
Contact reliability of the auxiliary contacts removable and can be replaced simply by unlocking and pulling
them out.
If voltages  110 V and currents  100 mA are to be switched,
the auxiliary contacts of the vacuum contactors or 3RH contac- 3TF6 vacuum contactors
tor relays should be used as they guarantee a high level of It is also possible replace the drive components of the vacuum
contact reliability.

3
contactor.
These auxiliary contacts are particularly suitable for solid-state
circuits with currents  1 mA at a voltage  17 V. Fitting auxiliary contacts and mounting additional auxiliary
switches
Vacuum interrupters Features in the delivery state
3RT12 vacuum contactors • 3RT12 vacuum contactors:
The contact gaps of the vacuum contactors are contained These contactors are supplied with two laterally mounted
in hermetically enclosed vacuum interrupters unlike the auxiliary switches with two contacts each (2 NO + 2 NC)
3RT10 contactors – the main contacts operate in air under • 3TF6 vacuum contactors:
atmospheric conditions. The particular benefit of vacuum These contactors are supplied with four laterally mounted
contactors, however, is that their electrical endurance is auxiliary switches with two contacts each (4 NO + 4 NC).
significantly higher. For operating mechanism versions with 3TC (3 NO + 3 NC)
series contactor, two auxiliary contacts are already defined.
They are especially suited to frequent switching in inching/mixed
operation, e.g. in crane control systems. Expansion possibilities
3TF6 vacuum contactors • 3RT12 vacuum contactors:
All basic devices can be expanded via auxiliary switches.
The switching contacts of the vacuum contactors are contained The permitted configuration must be taken into account.
in hermetically enclosed vacuum interrupters.
• Vacuum contactor 3TF6:
With these contactors, the contact erosion of the vacuum These devices are already fully equipped and no expansion
interrupters can be checked in the energized state with the help is possible.
of three white double slides below the connecting bars on the
outgoing side.
Operating mechanism types
3RT12 vacuum contactors
The contactors can be operated with AC (50 to 60 Hz) as well as
with DC.
Two types of solenoid operation are available:
• Standard operating mechanism for AC and DC operation
(power consumption reduced from closing to closed),
version 3RT12..-.A
• Solid-state operating mechanism, version 3RT12..-.N
3TF6 vacuum contactors
• Standard version 3TF6.44-.C.7 with AC operation
• Version 3TF6.33-.Q.7 for AC control supply voltage subject to
strong interference:
Contactors in this version are more robust against
EMC interference and are therefore designed for operation in
systems with AC control supply voltage that is subject to
strong interference. A 3TC44 (3TY7684-0Q..) reversing
contactor with a series resistor fitted is used to switch over
to holding control. The reversing contactor can be mounted
separately. It is connected to the 3TF6 main contactor by
means of a pre-assembled connecting cable (approx. 1 m
long) with plug-in connectors.
This version is recommended in the environment of frequency
converters and in the case of unshielded control cables.
• 3TF6.33-.D.4 contactors with DC control are supplied with
a 3TC4417-4A.. reversing contactor and a series resistor.

Siemens IC 10 · 2023 3/121


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors

■ Technical specifications
Unless otherwise listed on subsequent pages, the technical
specifications of the SIRIUS 3RT12 vacuum contactors More information
correspond to those of the 3RT10 basic units; see pages 3/25, Technical specifications, see
and 3/41 to 3/46. https://support.industry.siemens.com/cs/ww/en/ps/16137/td
FAQs, see
https://support.industry.siemens.com/cs/ww/en/ps/16137/faq
System Manual for modular system, see
3

https://support.industry.siemens.com/cs/ww/en/view/60311318
Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60306557
Application Manual - Switching devices with IE3 and IE4 motors, see
https://support.industry.siemens.com/cs/ww/en/view/94770820
Configuration Manual for load feeders, see
https://support.industry.siemens.com/cs/ww/en/view/39714188
Configuration Manual for UL, see
https://support.industry.siemens.com/cs/ww/en/view/53433538
Guide of use for contactors in safety applications, see
https://support.industry.siemens.com/cs/ww/en/view/109807687

SIRIUS vacuum contactors


Type 3RT12
Size S10 and S12
Contact endurance of the main contacts
The characteristic curves show the contact endurance of the
contactors when switching low inductive or non-inductive AC loads Operating cycles at
(AC-1) and motor-driven loads (AC-3 and AC-3e) depending on the
230 V
500 V

690 V

400 V

breaking current and rated operational voltage. It is assumed that Contactor 3RT1264 3RT1265 3RT1266 3RT1275 3RT1276
the operating mechanisms are switched arbitrarily and not type (110 kW) (132 kW) (160 kW) (200 kW) (250 kW)
synchronously with the phase angle of the supply system switching 7
10
operating mechanism. 107 8 6 8 NSB0_01142a
8 6 4 6
The rated operational current Ie complies with utilization 6 4 4
category AC-4 (breaking 6 times the rated operational current) 4 2
and is intended for a contact endurance of approximately 2 6 2
200 000 operating cycles. 2 6 10
10 6
6 8 10
If a shorter contact endurance is sufficient, the rated operational 10 8 6 8
current Ie/AC-4 can be increased. 8 6 4 6
6 4 4
If the contacts are used for mixed operation, i.e. normal switching 4 2
(breaking the rated operational current according to utilization 2 5 2
category AC-3 and AC-3e) in combination with intermittent inching 2 5 10
10 5
(breaking several times the rated operational current according to 5 8 10
10 8 6 8
utilization category AC-4), the contact endurance can be 8 6 4 6
calculated approximately from the following equation: 6 4 4
4 2
A 2 2
X = ---------------------------------------------------------- 2 4
4 10
1 + ----------  ---- – 1
C A 4
10
100  B  8 10
40 50 60 80 100 200 300 400 600 8001 000 2 000 3 000
Characters in the equation: Breaking current a(A)
X Contact endurance for mixed operation in operating cycles
A Contact endurance for normal operation
(Ia = Ie) in operating cycles
B Contact endurance for inching
(Ia = multiple of Ie) in operating cycles
C Inching operations as a percentage of
total switching operations

3/122 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors

Vacuum contactors
Type 3TF6
Size 14
Rated data of the auxiliary contacts According to IEC 60947-5-1
Rated insulation voltage Ui V 690
(pollution degree 3)
Conventional thermal current Ith = A 10
rated operational current Ie/AC-12

3
AC load
Rated operational current Ie/AC-15/AC-14
• At rated operational voltage Ue - At 24 V A 10
- At 110 V A 10
- At 125 V A 10
- At 220 V A 6
- At 230 V A 5.6
- At 380 V A 4
- At 400 V A 3.6
- At 500 V A 2.5
- At 660 V A 2.5
- At 690 V A 2.3
DC load
Rated operational current Ie/DC-12
• At rated operational voltage Ue - At 24 V A 10 10 10
- At 60 V A 10 10 10
- At 110 V A 3.2 3.2 3.2
- At 125 V A 2.5 2.5 2.5
- At 220 V A 0.9 0.9 0.9
- At 440 V A 0.33 0.33 0.33
- At 600 V A 0.22 0.22 0.22
Rated operational current Ie/DC-13 Auxiliary contacts with
delayed NC contact: N S = No specification
• At rated operational voltage Ue - At 24 V A 10 6
- At 60 V A 5 NS
- At 110 V A 1.14 0.98
- At 125 V A 0.98 NS
- At 220 V A 0.48 NS
- At 440 V A 0.13 NS
- At 600 V A 0.07 0.07
s and u rated data of the auxiliary contacts
Rated voltage, max. V AC 600
Switching capacity A 600, P 600

Siemens IC 10 · 2023 3/123


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors

Vacuum contactors
Type 3TF6
Size 14
Electrical endurance of auxiliary contacts
The electrical endurance for utilization category
AC-12 or AC-15/AC-14 depends mainly on 4 NSB0_00651b
the breaking current. It is assumed that the 3
operating mechanisms are switched arbitrarily 2

Operating cycles
and not synchronously with the phase angle of
3

the supply system switching operating 7


10
mechanism. 8
6
The characteristic curves apply to 230 V AC.
4
3
2
6
10
8
6
4
3
2
5
10
-2 -1 0 1
10 2 3 4 6 8 10 2 3 4 6 8 10 2 3 4 6 8 10 2
Breaking current a (A)

Contact endurance of the main contacts


The characteristic curves show the contact
endurance of the contactors when switching low Operating cycles at
inductive or non-inductive AC loads (AC-1) and
230 V

500 V

690 V

400 V

motor-driven loads (AC-3 and AC-3e)


depending on the breaking current and rated
operational voltage. It is assumed that the Contactor type 3TF68 3TF69
7 8 107
operating mechanisms are switched arbitrarily 10 6 8 NSB0_00654b
and not synchronously with the phase angle of 8 6 6
4
the supply system switching operating 6 4 4
mechanism. 4 2
2
The rated operational current Ie complies with 6 2
2 6 10
utilization category AC-4 (breaking 6 times 10 8 106
the rated operational current) and is intended 6 8
10 6 8
for a contact endurance of approximately 8 6
4 6
200 000 operating cycles. 6 4 4
If a shorter contact endurance is sufficient, 4 2
the rated operational current Ie/AC-4 can be 2 2
increased. 2 5
5 10
10 8 105
If the contacts are used for mixed operation, 5 8 6 8
10
i.e. normal switching (breaking the rated 8 6
operational current according to utilization 4 6
6 4
category AC-3 and AC-3e) in combination with 4
4 2
intermittent inching (breaking several times the 2
rated operational current according to utilization 2
2 4
category AC-4), the contact endurance can be 4 10
10 8 10 4
calculated approximately from the following 4 8 6 8
equation: 10
8 6
4 6
A 6 4
X = ---------------------------------------------------------- 4
4
1 + ----------  ---- – 1
C A 2
2 2
100 B 3
2 3 10
Characters in the equation: 10 10
3

X Contact endurance for mixed operation 100 200 400 600 1 000 2 000 4 000 6 000
in operating cycles Breaking current a (A)
A Contact endurance for normal operation
(Ia = Ie) in operating cycles
B Contact endurance for inching
(Ia = multiple of Ie) in operating cycles
C Inching operations as a percentage of total
switching operations

3/124 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors

SIRIUS vacuum contactors Vacuum contactors


Type 3RT126 3RT127 3TF68 3TF69
Size S10 S12 14
General data
Dimensions (W x H x D) : mm 145 x 210 x 206 160 x 214 x 225 230 x 276 x 237 230 x 295 x 237

3
'
Permissible mounting position

NSB0_00649a
NSB0_00650c
22,5° 22,5° 22,5° 22,5° 22,5° 22,5°
The contactors are designed for operation on a vertical 90° 90°
mounting surface.

• To easily replace the laterally mounted auxiliary switches No Yes


it is recommended to maintain a minimum clearance of
30 mm between the contactors.
• If mounted at a 90° angle (conducting paths are No Yes
horizontally above each other), the switching frequency
is reduced to 80% compared with the normal values.
Mechanical endurance Oper- 10 million 5 million
ating
cycles
Electrical endurance
Contact endurance of the main contacts See page 3/122 See page 3/124
Rated insulation voltage Ui kV 1
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 8
Protective separation between the coil and the main V 690 1 000
contacts according to IEC 60947-1, Annex N
Mirror contacts Yes, according to IEC 60947-4-1, Annex F Yes, according to IEC 60947-4-1, Annex F
A mirror contact is an auxiliary NC contact that cannot be One NC contact each must be connected in
closed simultaneously with an NO main contact. series for the left and right auxiliary switch
respectively.
Permissible ambient temperature
• During operation °C -25 ... +60 -25 ... +551)
• During storage °C -55 ... +80 -55 ... +80
Electromagnetic compatibility (EMC) See page 3/121
Short-circuit protection
Main circuit
Fuse links, operational class gG:
LV HRC, type 3NA; DIAZED, type 5SB; NEOZED,
type 5SE according to IEC 60947-4-1
• Type of coordination "1" A 500 800 1 000 1 250
• Type of coordination "2" A 500 800 500 630
• Weld-free (test conditions according to IEC 60947-4-1) A 400 500 400 500
Auxiliary circuit
Short-circuit test
• Fuse links, operational class gG: A 10
DIAZED, type 5SB; NEOZED, type 5SE
(weld-free protection at Ik  1 kA)
• Miniature circuit breaker with C characteristic A 10
(short-circuit current Ik  400 A)
Short-circuit protection for contactors with overload relays See Configuration Manual for load feeders
1)
For ambient temperatures > 55 °C, only 3TF6.33-.Q..-Z A02 contactors
(= without connection of the main conducting paths) can be used.
However, derating must be taken into account for these contactors too:
- AC-1: Ie = 782 A, 644 operating cycles/h;
- AC-3/AC-3e: Operating range 0.85 to 1.05 x Us, 460 operating cycles/h,
mech. service life 5 million operating cycles, lateral clearance 10 mm.

Siemens IC 10 · 2023 3/125


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors

SIRIUS vacuum contactors Vacuum contactors


Type 3RT126 3RT127 3TF68 3TF69
Size S10 S12 14
Control
Solenoid coil operating range AC/DC 0.8 x Us min ... 1.1 x Us max 0.8 x Us min ... 1.1 x Us max
Power consumption of the solenoid coils
(for cold coil and 1.0 x Us)
• Standard operating
3

mechanism
(3RT10..-.A)
- AC operation Closing at Us min/Us max VA 530/630 700/830 --
P.f. 0.9 --
Closed at Us min/Us max VA 6.1/7.4 7.6/9.2 --
P.f. 0.9 --
- DC operation Closing at Us min/Us max W 580/780 770/920 --
Closed at Us min/Us max W 6.8/8.2 8.5/10 --
• Solid-state operating
mechanism
(3RT10..-.N/-.P)
- AC operation Closing at Us min/Us max VA 420/570 560/750 --
P.f. 0.8 --
Closed at Us min/Us max VA 5.5/8.5 5.6/9 --
P.f. 0.5/0.4 --
- DC operation Closing at Us min/Us max W 460/630 600/800 --
Closed at Us min/Us max W 2.8/3.4 3/3.6 --
• Solid-state operating
mechanism
- AC operation Closing at Us min/Us max VA -- 1 200/1 850 600/950
(3TF6...-.C) P.f. -- 1 0.98
Closed at Us min/Us max VA -- 13.5/49 12.9/30.6
P.f. -- 0.15 0.31
- AC operation Closing at Us min VA -- 1 000 1 150
(3TF6...-.Q) P.f. -- 0.99
Closed at Us min VA -- 11
P.f. -- 1
- DC operation1) Closing at Us min W -- 1 010 960
(3TF6...-.D) Closed at Us min W -- 28 20.6
PLC control input according to IEC 61131-2 Type 2 --
• Rated voltage V DC 24 --
• Operating range V DC 17 ... 30 --
• Power consumption mA  30 --
Minimum command Standard ms -- 120
duration Reduced make-time ms -- 90 --
For closing
Minimum interval time between two ON commands ms -- 100 300
1)
At 24 V DC; for further voltages, deviations of up to  10% are possible.

3/126 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors

SIRIUS vacuum contactors Vacuum contactors


Type 3RT1264 3RT1265 3RT1266 3RT1275 3RT1276 3TF68 3TF69
Size S10 S12 14
Rated data of the main contacts
Load rating with AC
Utilization category AC-3 and AC-3e
• Rated operational currents Ie - Up to 690 V A 225 265 300 400 500 630 820 (630)1)
- Up to 1 000 V A 225 265 300 400 500 435 580

3
• Rated power for slip-ring or - At 230 V kW 55 75 90 132 160 200 260 (200)1)
squirrel-cage motors - At 400 V kW 110 132 160 200 250 335 450 (335)1)
at 50 and 60 Hz - At 500 V kW 160 160 200 250 335 -- --
- At 690 V kW 200 250 250 400 500 600 800 (600)1)
- At 1 000 V kW 315 355 400 560 710 600 800
Thermal load capacity, 10 s current A 1 800 2 120 2 400 3 200 4 000 5 040 7 000
Power loss per main conducting path at Ie/AC-3/AC-3e/400 V W 9 12 14 21 32 45 70
Utilization category AC-4 (at Ia = 6 x Ie)
Maximum values:
• Rated operational current Ie - Up to 690 V A 195 230 280 350 430 610 690
• Rated power - At 400 V kW 110 132 160 200 250 355 400
for squirrel-cage motors
at 50 Hz and 60 Hz
The following applies to a contact endurance of about
200 000 operating cycles:
• Rated operational currents Ie - Up to 690 V A 97 115 140 175 215 300 360
- Up to 1 000 V A 68 81 98 123 151 210 250
• Rated power - At 230 V kW 30 37 45 56 70 97 110
for squirrel-cage motors - At 400 V kW 55 65 79 98 122 168 191
at 50 Hz and 60 Hz - At 500 V kW 68 81 98 124 153 2102) 2502)
- At 690 V kW 94 112 138 172 212 2782) 3352)
- At 1 000 V kW 95 114 140 183 217 2902) 3502)
1)
Value applies for utilization category AC-3e.
2) Max. permissible rated operational current Ie/AC-4 = Ie/AC-3/AC-3e up to
500 V, for reduced contact endurance and reduced switching frequency.

Siemens IC 10 · 2023 3/127


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors

SIRIUS vacuum contactors Vacuum contactors


Type 3RT126 3RT127 3TF68 3TF69
Size S10 S12 14
Conductor cross-sections
Main conductors (1 or 2 conductors can be connected) Screw terminals

With mounted box terminals Type 3RT1966-4G --


• Terminal screws M12 (hexagon socket, A/F 5) --
3

- Tightening torque Nm 20 ... 22 (180 ... 195 lb.in) --


Front clamping point connected
• Finely stranded with end sleeve (DIN 46228) mm2 70 ... 240 --
mm2
NSB0_00479

• Finely stranded without end sleeve 70 ... 240 --


• Stranded mm2 95 ... 300 --
• AWG cables, solid or stranded AWG 3/0 ... 600 kcmil --
• Ribbon cable conductors mm Min. 6 x 9 x 0.8; max. 20 x 24 x 0.5 --
(number x width x thickness)
Rear clamping point connected
• Finely stranded with end sleeve (DIN 46228) mm2 120 ... 185 --
NSB0_00480

• Finely stranded without end sleeve mm2 120 ... 185 --


• Stranded mm2 120 ... 240 --
• AWG cables, solid or stranded AWG 250 ... 500 kcmil --
• Ribbon cable conductors mm Min. 6 x 9 x 0.8; max. 20 x 24 x 0.5 --
(number x width x thickness)
Both clamping points connected
• Finely stranded with end sleeve (DIN 46228) mm2 Min. 2 x 50, max. 2 x 185 --
• Finely stranded without end sleeve mm2 Min. 2 x 50, max. 2 x 185 --
NSB0_00481

• Stranded mm2 Min. 2 x 70, max. 2 x 240 --


• AWG cables, solid or stranded AWG Min. 2 x 2/0, max. 1 x 500 kcmil --
• Ribbon cable conductors mm Max. 2 x (20 x 24 x 0.5) --
(number x width x thickness)
Cable lug connection
• Finely stranded with cable lug1) mm2 50 ... 240 --
• Stranded with cable lug1) mm2 70 ... 240 --
• AWG cables, solid or stranded AWG 2/0 ... 500 kcmil --
• Terminal screws M10 x 30 (A/F 17) --
- Tightening torque Nm 14 ... 24 (124 ... 210 lb.in) --
Busbar connections
• Finely stranded with cable lug mm2 -- 50 ... 240
• Stranded with cable lug mm2 -- 70 ... 240 50 ... 240
• Solid or stranded AWG -- 2/0 ... 500 MCM 2/0 ... 500 MCM
• Connecting bar (max. width) mm 25 50 60 (Ue  690 V),
50 (Ue > 690 V)
• Terminal screws -- M10 x 30 M12 x 40
- Tightening torque Nm -- 14 ... 24 20 ... 35
lb.in -- 124 ... 210 177 ... 310
With box terminal (see page 3/134)
• Connectable laminated copper bars -- Yes
• Width mm -- 15 ... 25 15 ... 38
• Max. thickness mm -- 1 x 26 or 2 x 11 1 x 46 or 2 x 18
• Terminal screw -- A/F 6 A/F 8
(hexagon socket) (hexagon socket)
• Tightening torque Nm -- 25 ... 40 35 ... 50
(221 ... 354 lb.in) (266 ... 443 lb.in)
Auxiliary conductors (1 or 2 conductors can be connected)
• Solid mm2 2 x (0.5 ... 1.5)2); 2 x (0.75 ... 2.5)2) 2 x (0.5 ... 1)2)/2 x (1 ... 2.5)2)
according to IEC 60947; max. 2 x (0.75 ... 4)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)2); 2 x (0.75 ... 2.5)2) 2 x (0.5 ... 1)2), 2 x (0.75 ... 2.5)2)
• Pin cable lug according to DIN 46231 mm2 -- 2 x (1 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (18 ... 14) 2 x (18 ... 12)
• Terminal screws M3 (Pozidriv size 2) --
- Tightening torque Nm 0.8 ... 1.2 (7 ... 10.3 lb.in) 0.8 ... 1.4 (7 ... 12 lb.in)
1) When connecting cable lugs according to DIN 46234 for conductor cross- 2) If two different conductor cross-sections are connected to one clamping
sections larger than 240 mm2 and according to DIN 46235 for conductor point, both cross-sections must lie in one of the ranges specified.
cross-sections larger than 185 mm2, the 3RT1966-4EA1 terminal cover is
required to maintain the phase clearance, see page 3/112.

3/128 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors

SIRIUS vacuum contactors Vacuum contactors


Type 3RT1264 3RT1265 3RT1266 3RT1275 3RT1276 3TF68 3TF69
Size S10 S12 14
s and u rated data
Rated insulation voltage V AC 600 600
Uninterrupted current at 40 °C, open and enclosed A 330 540 630 820
Maximum horsepower ratings
(from s and u approved values)

3
• Rated power for three-phase motors at 60 Hz
- At 200 V hp 60 75 100 125 150 231 290
- At 230 V hp 75 100 125 150 200 266 350
- At 460 V hp 150 200 250 300 400 530 700
- At 575 V hp 200 250 300 400 500 664 860
NEMA/EEMAC ratings
SIZE hp -- 6 7
• Uninterrupted current
- Open A -- 600 820
- Enclosed A -- 540 810
• Rated power for three-phase motors at 60 Hz
- At 200 V hp -- 150 --
- At 230 V hp -- 200 300
- At 460 V hp -- 400 600
- At 575 V hp -- 400 600
Short-circuit protection1) kA 10 18 30 100
• CLASS L fuse A 600 700 800 1 000 1 200 1 600
• Circuit breakers according to UL 489 A 500 700 800 1 000 1 200 On request1)
1) For more information about short-circuit values, e.g. for protection against
high short-circuit currents, see Certificate of Compliance for the individual
devices.
For the selection and dimensioning of load feeders, see
Configuration Manual for UL and the
UL guide "Competitive control panels for the North American market".

Siemens IC 10 · 2023 3/129


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors IE3 ready IE4 ready IE3/IE4 ready
AC-3e

■ Selection and ordering data


SIRIUS 3RT12 vacuum contactors, 3-pole, 110 to 250 kW
AC/DC operation
• Standard operating mechanism 3RT12..-.A • Auxiliary and control conductors: Screw terminals
• 3RT12..-.N solid-state operating mechanism with 24 V DC • Main conductors: Busbar connections;
control signal input a connection kit with screws, spring washers and nuts
• For screw fixing is enclosed.
3

3RT1264-6AF36 3RT127.-6N.36
Size Rated data Auxiliary Rated control Screw terminals PU PS* PG
AC-3 and AC-3e, AC-1, contacts, supply (UNIT,
tu: up to 60 °C tu: 40 °C lateral voltage Us SET, M)
50/60 Hz AC
or DC
Opera- Rating of Opera- Article No. Price
tional three-phase motors tional per PU
current Ie at 50 Hz and current Ie
up to up to
1 000 V 230 V 400 V 500 V 690 V 1 000 V
A kW kW kW kW A NO NC V
Standard operating mechanism for AC and DC operation
(power consumption reduced from closing to closed)
With integrated coil circuit (varistor integrated at the factory)
S10 225 55 110 160 200 330 2 2 110 ... 127 3RT1264-6AF36 1 1 unit 41B
220 ... 240 3RT1264-6AP36 1 1 unit 41B
265 75 132 160 250 330 2 2 110 ... 127 3RT1265-6AF36 1 1 unit 41B
220 ... 240 3RT1265-6AP36 1 1 unit 41B
300 90 160 200 250 330 2 2 110 ... 127 3RT1266-6AF36 1 1 unit 41B
220 ... 240 3RT1266-6AP36 1 1 unit 41B
S12 400 132 200 250 400 610 2 2 110 ... 127 3RT1275-6AF36 1 1 unit 41B
220 ... 240 3RT1275-6AP36 1 1 unit 41B
500 160 250 355 500 610 2 2 110 ... 127 3RT1276-6AF36 1 1 unit 41B
220 ... 240 3RT1276-6AP36 1 1 unit 41B
Solid-state operating mechanism
With 24 V DC control signal input
e.g. for control by PLC
With integrated coil circuit (varistor integrated in electronics at the factory)
S10 225 55 110 160 200 330 2 2 96 ... 127 3RT1264-6NF36 1 1 unit 41B
200 ... 277 3RT1264-6NP36 1 1 unit 41B
265 75 132 160 250 330 2 2 96 ... 127 3RT1265-6NF36 1 1 unit 41B
200 ... 277 3RT1265-6NP36 1 1 unit 41B
300 90 160 200 250 330 2 2 96 ... 127 3RT1266-6NF36 1 1 unit 41B
200 ... 277 3RT1266-6NP36 1 1 unit 41B
S12 400 132 200 250 400 610 2 2 96 ... 127 3RT1275-6NF36 1 1 unit 41B
200 ... 277 3RT1275-6NP36 1 1 unit 41B
500 160 250 355 500 610 2 2 96 ... 127 3RT1276-6NF36 1 1 unit 41B
200 ... 277 3RT1276-6NP36 1 1 unit 41B

Other voltages according to page 3/68 on request.


For an overview of the 3RT12 vacuum contactors with mountable
accessories, see pages 3/14 and 3/16.
The accessories for the 3RT1 vacuum contactors correspond to
those for the basic units of the 3RT1 contactors, see page 3/69
onwards.
For spare parts, see page 3/136.

* You can order this quantity or a multiple thereof.


3/130 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT12 and 3TF6 vacuum contactors
3TF6 vacuum contactors, 3-pole, 335 to 450 kW
AC operation
• For screw fixing
• Main conductors: Busbar connections
• Auxiliary and control conductors: Screw terminals
• With overvoltage protection of the coil (varistor)

3
3TF68 3TF69
Size Rated data Auxiliary Rated control Screw terminals PU PS* PG
AC-3 and AC-3e, AC-1, contacts, supply (UNIT,
tu: up to 55 °C tu: 40 °C lateral voltage Us SET, M)
50/60 Hz AC
Opera- Rating of Opera- Article No. Price
tional three-phase motors tional per PU
current Ie at 50 Hz and current
up to Ie up to
690 V 230 V 400 V 690 V 1 000 V 690 V
A kW kW kW kW A NO NC V
AC operation 50/60 Hz1)
14 630 200 335 600 -- 700 4 4 110 ... 132 3TF6844-0CF7 1 1 unit 41B
200 ... 240 3TF6844-0CM7 1 1 unit 41B
600 700 4 4 110 ... 132 3TF6844-8CF7 1 1 unit 41B
200 ... 240 3TF6844-8CM7 1 1 unit 41B
14 820 260 450 800 -- 910 4 4 110 ... 132 3TF6944-0CF7 1 1 unit 41B
(630)2) (200)2) (335)2) (600)2) 200 ... 240 3TF6944-0CM7 1 1 unit 41B
800 910 4 4 110 ... 132 3TF6944-8CF7 1 1 unit 41B
200 ... 240 3TF6944-8CM7 1 1 unit 41B
1)
Please observe the information regarding the use of 3TF6 vacuum Rated control supply voltages, possible on request
contactors in the environment of frequency converters, see page 3/120. (change of the 10th and 11th digits of the article number)
2)
Value applies for utilization category AC-3e.
Delivery time on request
For an overview of the 3TF6 vacuum contactors with mountable
accessories, see page 3/17. Rated control supply Contactor type 3TF6844-.C..,
voltage Us 3TF6944-.C..
Accessories and spare parts, see pages 3/133 to 3/137.
Size 14
AC operation
Solenoid coils for 50/60 Hz
110 ... 132 V AC F7
200 ... 240 V AC M7
230 ... 277 V AC P7
380 ... 460 V AC Q7
500 ... 600 V AC S7

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/131
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
SIRIUS 3RT12 and 3TF6 vacuum contactors IE3 ready IE4 ready IE3/IE4 ready
AC-3e
DC operation
and for AC control supply voltage subject to
strong interference
• Main conductors: Busbar connections
• Auxiliary and control conductors: Screw terminals
• Power consumption reduced from closing to closed

A1 3TF68,
A2 Main
3TF69
3

V contactor
V

6 Connecting
cable, 1 m
NSB0_01374a

3TC44 Reversing
contactor

Circuit diagram 3TF6833-1D.4 3TF6933-1Q.7


for AC operation, 50/60 Hz, with reversing contactor 3TC4417-0A with reversing contactor 3TC4417-0B
for AC control supply voltage
subject to strong interference
Size Rated data Auxiliary Rated control Screw terminals PU PS* PG
AC-3 and AC-3e, AC-1, contacts, supply voltage (UNIT,
tu: up to 55 °C tu: 40 °C lateral Us SET, M)
50/60 Hz
AC or DC
Opera- Rating of Opera- Article No. Price
tional three-phase motors tional per PU
current Ie at 50 Hz and current
up to Ie up to
690 V 230 V 400 V 690 V 1 000 V 690 V
A kW kW kW kW A NO NC V
DC operation1)
14 630 200 335 600 -- 700 3 3 24 DC 3TF6833-1DB4 1 1 unit 41B
600 700 3 3 24 DC 3TF6833-8DB4 1 1 unit 41B
14 820 260 450 800 -- 910 3 3 24 DC 3TF6933-1DB4 1 1 unit 41B
(630)2) (200)2) (335)2) (600)2) 800 910 3 3 24 DC 3TF6933-8DB4 1 1 unit 41B
AC operation 50/60 Hz1)3) ·
For AC control supply voltage subject to strong interference
14 630 200 335 600 -- 700 3 3 110 ... 120 AC 3TF6833-1QG7 1 1 unit 41B
220 ... 240 AC 3TF6833-1QL7 1 1 unit 41B
380 ... 420 AC 3TF6833-1QV7 1 1 unit 41B
600 700 3 3 220 ... 240 AC 3TF6833-8QL7 1 1 unit 41B
14 820 260 450 800 -- 910 3 3 110 ... 120 AC 3TF6933-1QG7 1 1 unit 41B
(630)2) (200)2) (335)2) (600)2) 220 ... 240 AC 3TF6933-1QL7 1 1 unit 41B
380 ... 420 AC 3TF6933-1QV7 1 1 unit 41B
800 910 3 3 110 ... 120 AC 3TF6933-8QG7 1 1 unit 41B
220 ... 240 AC 3TF6933-8QL7 1 1 unit 41B
1) Please observe the information regarding the use of 3TF6 vacuum Rated control supply voltages, possible on request
contactors in the environment of frequency converters, see page 3/120. (change of the 10th and 11th digits of the article number)
2)
Value applies for utilization category AC-3e.
3)
A DC solenoid system with rectifier is used in this version. Varistor Delivery time on request
integrated. A 3TC4417-.... reversing contactor with pre-assembled
connecting cable (approx. 1 m) and plug-in connector is included in the Rated control supply Contactor type 3TF6833-.D..,
scope of supply of the vacuum contactor. voltage Us 3TF6933-.D..
Size 14
For an overview of the 3TF6 vacuum contactors with mountable
accessories, see page 3/17. DC operation
Solenoid coils
Accessories and spare parts, see pages 3/133 to 3/137.
24 V DC B4
110 V DC F4
125 V DC G4
220 V DC M4
230 V DC P4

* You can order this quantity or a multiple thereof.


3/132 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories and spare parts for SIRIUS 3RT12 and 3TF6 vacuum contactors

■ Selection and ordering data


Accessories Overview graphics with mountable accessories:
For further accessories for the SIRIUS 3RT12 vacuum • 3RT12 contactors, see pages 3/14 and 3/16
contactors, see 3RT10 basic units, page 3/69 onwards. • 3TF68 and 3TF69 contactors, see page 3/17
For Auxiliary contacts Screw terminals PU PS* PG
contactors Version Connections (UNIT,
SET, M)

3
Article No. Price
per PU

Size Type NO NC NC Left Right


Auxiliary switches, instantaneous
For lateral mounting
14 3TF68, First auxiliary switch 3TY7561-1AA00 1 1 unit 41B
3TF69 1 1 -- 13 21 31 43

14 22 32 44

3TY7561-1AA00
3TF68, First auxiliary switch 3TY7561-1EA00 1 1 unit 41B
3TF69 1 -- 1 13 25 35 43

14 26 36 44

3TY7561-1EA00
3TF68, Second auxiliary switch 3TY7561-1KA00 1 1 unit 41B
3TF69 1 1 -- 53 61 71 83

54 62 72 84

3TY7561-1KA00
For switchover of the coil with DC circuit
14 3TF68, -- -- 1 B1 25 -- 3TY7681-1G 1 1 unit 41B
3TF69

B2 26

3TY7681-1G
Solid-state compatible auxiliary switches
For lateral mounting
14 3TF68, Second auxiliary switch, left or right 3TY7561-1UA00 1 1 unit 41B
3TF69 1 CO contact
51 61

52 54 62 64

5TY7561-1UA00

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/133
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories and spare parts for SIRIUS 3RT12 and 3TF6 vacuum contactors

For contactors Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)
Size Type

Main conducting path surge suppression modules


S10/ 3RT12 For damping overvoltages and protecting motor
S12 windings against multiple re-ignition when
switching off three-phase motors
3

For connection on the outgoing contactor side


3RT1966-1PV3 (2-T1/4-T2/6-T3), for separate installation
Rated operational voltage Ue
• 690 V AC 3RT1966-1PV3 1 1 unit 41B
• 1 000 V AC 3RT1966-1PV4 1 1 unit 41B
3RT1966-1PV4
Box terminal blocks for connecting auxiliary conductors to main terminals
For round and ribbon cables
Connectable cross-sections of the contactors,
see Technical specifications, page 3/128.
S10/ 3RT12 • Up to 240 mm2, 3RT1966-4G 1 1 unit 41B
S12 with auxiliary conductor connection up to
2.5 mm2

3RT1966-4G
Surge suppressors
14 3TF68, Varistors
3TF69 AC operation
The surge suppressor (varistor) is included in
the scope of supply of the 3TF68 and 3TF69
contactors with AC operation.
DC operation
3TX7572-3.
Varistor for snapping onto the side of the auxiliary
switch (includes the peak value of the alternating
voltage on the DC side),
connection to A1 and A2
Rated control supply voltage Us
• 24 ... 48 V DC 3TX7572-3G 1 1 unit 41B
• 127 ... 240 V DC 3TX7572-3J 1 1 unit 41B
Terminal covers
14 3TF68 For protection against inadvertent contact, 3TX7686-0A 1 1 unit 41B
3TF69 two units required per contactor 3TX7696-0A 1 1 unit 41B
(1 set = 2 units)

3TX76.6-0A
3TF68 On the outgoing side combined with overload 3TX7686-0B 1 1 unit 41B
relay, for protection against inadvertent contact
with exposed busbar connections
3TX7686-0B
Links for paralleling (star jumpers), 3-pole
14 3TF68, without connecting terminal 3TX7680-0D 1 1 unit 41B
3TF69 (the link for paralleling can be reduced
by one pole)
3TX7680-0D
Box terminals for laminated copper bars
14 3TF68 Without auxiliary conductor connection 3TX7570-1E 1 1 unit 41B
(1 set = 3 units)
With single covers for protection against
3TX7570-1E inadvertent contact (IEC 60529)
3TF69 With auxiliary conductor connection 3TX7690-1F 1 1 unit 41B
(1 set = 3 units)
Conductor cross-sections for auxiliary conductors:
3TX7690-1F • Solid 2 x (0.75 ... 2.5) mm2
• Finely stranded with end sleeve
2 x (0.5 ... 2.5) mm2
• AWG, solid or stranded 2 x (18 ... 12)
• Tightening torque 0.8 ... 1.4 Nm (7 ... 12 lb.in)

* You can order this quantity or a multiple thereof.


3/134 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories and spare parts for SIRIUS 3RT12 and 3TF6 vacuum contactors

For contactors Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)
Size Type

Locking devices for mechanical interlock


14 3TF68- For two contactors of the same size, 3TX7686-1A 1 1 unit 41B
3TF68 for mounting on base plate

3
3TX7686-1A
Base plates
For reversing contactor assemblies
14 3TF68- For customer assembly of reversing contactor 3TX7681-1A 1 1 unit 41B
3TF68 assemblies

3TX7681-1A
For contactor assemblies for star-delta
(wye-delta) starting
14 3TF68- For configuring contactor assemblies for 3TX7681-1B 1 1 unit 41B
3TF68- star-delta (wye-delta) starting
3RT1.7

3TX7681-1B
Assembly kits for contactor assemblies
For reversing contactor assemblies
14 3TF68- The assembly kit contains: 3TX7680-1A 1 1 unit 41B
3TF68 wiring modules on the top and bottom

3TX7680-1A
For contactor assemblies for star-delta
(wye-delta) starting
14 3TF68- The assembly kit contains: 3TX7680-1B 1 1 unit 41B
3TF68- Wiring modules on the top and bottom,
3RT1.7 Star jumper S12

3TX7680-1B

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/135
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories and spare parts for SIRIUS 3RT12 and 3TF6 vacuum contactors
Spare parts
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
For contactors Rated control supply voltage Screw terminals Spring-loaded
Us min to Us max terminals
Article No. Price Article No. Price
Size Type V AC/DC per PU per PU
3

Withdrawable coils
Standard operating mechanism for AC/DC
S10 3RT126 23 ... 26 3RT1966-5AB31 --
42 ... 48 3RT1966-5AD31 --
110 ... 127 3RT1966-5AF31 --
200 ... 220 3RT1966-5AM31 --
220 ... 240 3RT1966-5AP31 --
240 ... 277 3RT1966-5AU31 --
380 ... 420 3RT1966-5AV31 --
440 ... 480 3RT1966-5AR31 --
500 ... 550 3RT1966-5AS31 --
3RT1975-5A.31 575 ... 600 3RT1966-5AT31 --
S12 3RT127 23 ... 26 3RT1975-5AB31 3RT1975-5AB32
42 ... 48 3RT1975-5AD31 3RT1975-5AD32
110 ... 127 3RT1975-5AF31 3RT1975-5AF32
200 ... 220 3RT1975-5AM31 3RT1975-5AM32
220 ... 240 3RT1975-5AP31 3RT1975-5AP32
240 ... 277 3RT1975-5AU31 3RT1975-5AU32
380 ... 420 3RT1975-5AV31 3RT1975-5AV32
440 ... 480 3RT1975-5AR31 3RT1975-5AR32
500 ... 550 3RT1975-5AS31 3RT1975-5AS32
3RT1975-5A.32 575 ... 600 3RT1975-5AT31 3RT1975-5AT32

Solid-state operating mechanism for AC/DC


with 24 V DC control signal input
e.g. for control by PLC
S10 3RT126 21 ... 27.3 3RT1966-5NB31 --
96 ... 127 3RT1966-5NF31 --
200 ... 277 3RT1966-5NP31 --
S12 3RT127 21 ... 27.3 3RT1975-5NB31 3RT1975-5NB32
96 ... 127 3RT1975-5NF31 3RT1975-5NF32
200 ... 277 3RT1975-5NP31 3RT1975-5NP32
3RT1975-5N.31

* You can order this quantity or a multiple thereof.


3/136 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
Accessories and spare parts for SIRIUS 3RT12 and 3TF6 vacuum contactors

For contactors Version Rated control Article No. Price PU PS* PG


supply voltage per PU (UNIT,
Us SET, M)
Size Type V
Solenoid coils
AC operation 50/60 Hz AC
14 3TF68 The solenoid coils are fitted 110 ... 132 3TY7683-0CF7 1 1 unit 41B
as standard with varistors 200 ... 240 3TY7683-0CM7 1 1 unit 41B
against overvoltage; the coil 230 ... 277 3TY7683-0CP7 1 1 unit 41B

3
is supplied with switch-on 200 ... 240 3TY7683-0CQ7 1 1 unit 41B
electronics. 380 ... 460 3TY7683-0CS7 1 1 unit 41B
3TF69 110 ... 132 3TY7693-0CF7 1 1 unit 41B
200 ... 240 3TY7693-0CM7 1 1 unit 41B
3TY76.3-0C.. 230 ... 277 3TY7693-0CP7 1 1 unit 41B
200 ... 240 3TY7693-0CQ7 1 1 unit 41B
380 ... 460 3TY7693-0CS7 1 1 unit 41B
DC operation
14 3TF68 The solenoid coils are 24 DC 3TY7683-0DB4 1 1 unit 41B
supplied without reversing 110 DC 3TY7683-0DF4 1 1 unit 41B
3TY7683-0D.. contactor. 125 DC 3TY7683-0DG4 1 1 unit 41B
220 DC 3TY7683-0DM4 1 1 unit 41B
230 DC 3TY7683-0DP4 1 1 unit 41B
Vacuum interrupters
S10 3RT1264 Set with three vacuum -- 3RT1964-6V 1 1 unit 41B
3RT1265 interrupters with fixing parts -- 3RT1965-6V 1 1 unit 41B
3RT1266 -- 3RT1966-6V 1 1 unit 41B
S12 3RT1275 -- 3RT1975-6V 1 1 unit 41B
3RT1276 -- 3RT1976-6V 1 1 unit 41B
3RT197.-6V
14 3TF68 Set with three vacuum -- 3TY7680-0B 1 1 unit 41B
3TF69 interrupters with components -- 3TY7690-0B 1 1 unit 41B
Note:
In order to ensure reliable
operation of the contactors,
only original replacement
interrupters should be used.

3TY7690-0B

For contactors Version Rated control Article No. Price PU PS* PG


supply voltage per PU (UNIT,
Us SET, M)
50/60 Hz AC
Size Type V
Solenoid coils for main contactors
14 3TF68..-.Q With rectifier bridge 220 ... 240 3TY7683-0QL7 1 1 unit 41B
14 3TF69..-.Q With rectifier bridge 110 ... 120 3TY7693-0QG7 1 1 unit 41B
220 ... 240 3TY7693-0QL7 1 1 unit 41B
3TC44 reversing contactors
14 3TF68..-.Q, Complete with series resistor, 110 ... 120 3TY7684-0QG7 1 1 unit 41B
3TF69..-.Q 1 m connecting cable and 220 ... 240 3TY7684-0QL7 1 1 unit 41B
plug-in connector 380 ... 420 3TY7684-0QV7 1 1 unit 41B

3TY7684-0Q.7
AC solenoid operating mechanism with coil
14 3TF6844-.C Solenoid operating 200 ... 240 3TY7685-0CM7 1 1 unit 41B
mechanism with coil 230 ... 276 3TY7685-0CP7 1 1 unit 41B
380 ... 420 3TY7685-0CS7 1 1 unit 41B

3TY7685-0C.7

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/137
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
3TG10 power relays/miniature contactors

■ Overview ■ Application
Standards Because they are hum-free they are suitable for use in
household appliances and distribution boards in office and
IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1 residential areas.
Version They can also be used for applications where there is little
The 3TG10 power relays/miniature contactors are available with space, such as air conditioners, heating systems, pumps
screw terminals or 6.3 mm × 0.8 mm flat connectors. and fans, i.e. for simple electrical controls.
3

The 3TG10 miniature contactors are characterized by their width


of just 36 mm.
Protection of the device connections from overvoltage
The 3TG10 power relays/miniature contactors have an
integrated protective circuit against switching overvoltages.

■ Technical specifications
More information
Technical specifications, see Reference Manual for switching devices, see
https://support.industry.siemens.com/cs/ww/en/ps/16186/td https://support.industry.siemens.com/cs/ww/en/view/35554359
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16186/faq

Type 3TG10
General data
Dimensions (W x H x D) mm 36 x 56 x 56
H

Endurance
• Mechanical Operating cycles 3 million
• Electrical
- AC-1 at Ie Operating cycles 0.1 million
- AC-3/AC-3e at Ie Operating cycles 0.4 million
Rated insulation voltage Ui (pollution degree 3) V 400
Rated impulse withstand voltage Uimp kV 4
Protective separation
Between the coil and the contacts according to IEC 60947-1, Annex N V Up to 300
Permissible ambient temperature
• During operation1) °C -25 ... + 55
• During storage °C -50 ... + 80
Short-circuit protection
Fuse links, operational class gG:
LV HRC, type 3NA; DIAZED, type 5SB; NEOZED, type 5SE
according to IEC 60947-4-1
• Type of coordination "1" A 25
• Type of coordination "2" A 10
Miniature circuit breakers, C characteristic A 10
Control
Solenoid coil operating range 0.85 ... 1.1 x Us
Power consumption of the solenoid coils (for cold coil and 1.0 x Us)
• AC operation, 45 ... 450 Hz VA 4.4
- P.f. 0.9 (hum-free)
• DC operation W 4
Rated data of the main contacts
Load rating with AC
Utilization category AC-1
• Rated operational current Ie up to 400 V at 55 °C1) A 20 for screw terminals, 16 for flat connectors
• Rated power Ue for AC loads with p.f. = 1, 230/220 V
- For screw terminals kW 7.5 (13 at 400 V)
- For flat connectors kW 6 (10 at 400 V)
• Minimum conductor cross-section for loads with Ie mm2 2.5
1) If the three main conducting paths carry a load of 20 A, the following
applies if I > 10 A in the fourth conducting path: Permissible ambient
temperature 40 °C.

3/138 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
3TG10 power relays/miniature contactors

Type 3TG10
Rated data of the main contacts (continued)
Load rating with AC
Utilization category AC-3 and AC-3e
• Operational current for AC-3/AC-3e at Ue  400 V rated value A 8.4/6.4
• Rated power for slip-ring or squirrel-cage motors for kW 4/3
AC-3/AC-3e, at 50 and 60 Hz and at Ue  400 V
Utilization category AC-5a (permissible nominal impedance:  0.5 )

3
Switching of gas discharge lamps
Per main conducting path at 230 V, 50 Hz
Rated power Rated
per lamp operational
current per
lamp
• Uncompensated 18 W 0.37 A Unit(s) 43
36 W 0.43 A Unit(s) 37
58 W 0.67 A Unit(s) 24
• DUO switching 18 W 2 x 0.11 A Unit(s) 2 x 81
36 W 2 x 0.21 A Unit(s) 2 x 42
58 W 2 x 0.32 A Unit(s) 2 x 28
Switching of gas discharge lamps with compensation or ECG
Per main conducting path 230 V, 50 Hz
Connection Rated power Capacitor Rated
per lamp capacitance operational
current
per lamp
• Shunt compensation L18 W 4.5 µF 0.11 A Unit(s) 15
L36 W 4.5 µF 0.21 A Unit(s) 15
L58 W 7 µF 0.32 A Unit(s) 10
• With ECG (single lamp) L18 W 6.8 µF 0.10 A Unit(s) 39
L36 W 6.8 µF 0.18 A Unit(s) 39
L58 W 10 µF 0.27 A Unit(s) 26
• With ECG (two lamps) L18 W 10 µF 0.18 A Unit(s) 2 x 26
L36 W 10 µF 0.35 A Unit(s) 2 x 26
L58 W 22 µF 0.52 A Unit(s) 2 x 12
Utilization category AC-5b, switching incandescent lamps kW 1.6
Per main conducting path at 230 V, 50 Hz
Load rating with DC
Utilization category DC-1, (L/R  15 ms)
• Rated operational currents Ie
- 1 conducting path Up to 24 V A 16
60 V A 6
110 V A 2
220 V/240 V A 0.8
- 2 conducting paths in series Up to 24 V A 16
60 V A 16
110 V A 6
220 V/240 V A 1.6
- 3 conducting paths in series Up to 24 V A 18
60 V A 18
110 V A 16
220 V/240 V A 6
Utilization category DC-3 and DC-5
Shunt-wound and series-wound motors (L/R  15 ms)
• Rated operational currents Ie
- 1 conducting path Up to 24 V A 10
60 V A 0.5
110 V A 0.15
220 V/240 V A 0
- 2 conducting paths in series Up to 24 V A 16
60 V A 5
110 V A 0.35
220 V/240 V A 0
- 3 conducting paths in series Up to 24 V A 16
60 V A 16
110 V A 10
220 V/240 V A 1.75

Siemens IC 10 · 2023 3/139


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
3TG10 power relays/miniature contactors

Type 3TG10
Conductor cross-sections
Screw terminals

• Terminal screws M3
• Finely stranded with end sleeve (DIN 46228 Form A/D/C) mm2 2 x (0.75 ... 2.5)
• Solid mm2 2 x (1 ... 2.5), 1 x 4
• Permissible opening tool (screwdriver) 3.0 mm x 0.5 mm (3RA2908-1A) or Pozidriv 2
3

Flat connectors

• Finely stranded 6.3 mm plug-in sleeve according to DIN 46245/DIN 46247


- 6.3 ... 1 mm2 0.5 ... 1
- 6.3 ... 2.5 mm2 1 ... 2.5
s and u rating (screw terminals)
Rated insulation voltage V AC 600
Uninterrupted current Open and enclosed A 20
Maximum horsepower ratings 1-phase/3-phase
(from s and u approved values)
• Rated power for at 115 V hp 0.5/--
three-phase motors at 60 Hz 200 V hp 1/3
230 V hp 1.5/3
460 ... 600 V hp 0/5

3/140 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Power contactors for switching motors
AC-3e E3 ready IE4 ready IE3/IE4 ready 3TG10 power relays/miniature contactors

■ Selection and ordering data


AC operation or DC operation
For screw fixing and snap-on mounting on TH 35 DIN rail
Rated data Auxiliary Rated Article No. Price PU PS* PG
Utilization category contacts control per PU (UNIT,
AC-1 AC-3/AC-3e supply SET, M)
at 55 °C voltage
Us

3
Opera- Power of Opera- Power of Version
tional AC loads at tional AC loads at
current Ie 50 Hz and current Ie 50 Hz and
up to 400 V up to 400 V
400 V 400 V1)
A kW A kW NO NC V
Hum-free  with screw terminals
Screw terminals

AC operation, 45 ... 450 Hz


20 13 8.4/6.4 4/3 1 -- 24 AC 3TG1010-0AC2 1 1 unit 41H
110 AC 3TG1010-0AG2 1 1 unit 41H
230 AC 3TG1010-0AL2 1 1 unit 41H
-- 1 24 AC 3TG1001-0AC2 1 1 unit 41H
110 AC 3TG1001-0AG2 1 1 unit 41H
3TG10..-0... 230 AC 3TG1001-0AL2 1 1 unit 41H
DC operation
20 13 8.4/6.4 4/3 1 -- 24 DC 3TG1010-0BB4 1 1 unit 41H
-- 1 24 DC 3TG1001-0BB4 1 1 unit 41H
Hum-free  with 6.3 mm x 0.8 mm flat connectors
Flat connectors

AC operation, 45 ... 450 Hz


16 10 8.4/6.4 4/3 1 -- 24 AC 3TG1010-1AC2 1 1 unit 41H
110 AC 3TG1010-1AG2 1 1 unit 41H
230 AC 3TG1010-1AL2 1 1 unit 41H
-- 1 24 AC 3TG1001-1AC2 1 1 unit 41H
110 AC 3TG1001-1AG2 1 1 unit 41H
3TG10..-1... 230 AC 3TG1001-1AL2 1 1 unit 41H
DC operation
16 10 8.4/6.4 4/3 1 -- 24 DC 3TG1010-1BB4 1 1 unit 41H
-- 1 24 DC 3TG1001-1BB4 1 1 unit 41H
1) The rated operational currents apply to each pole.

■ Accessories
Version Max. rated operational Max. Screw terminals PU PS* PG
currents Ie/AC-1 conductor (UNIT,
(at 55 °C) of the cross-sections SET, M)
contactors
Article No. Price
A mm2 per PU
Links for paralleling (insulated star jumpers)1)
3-pole
• Without connecting 16 -- 3RT1916-4BA31 1 1 unit 41B
terminal
• With connecting terminal 40 25 3RT1916-4BB31 1 1 unit 41B
4-pole
3RT1916-4BB31 • With connecting terminal 40 25 3RT1916-4BB41 1 1 unit 41B
1)
The links for paralleling can be reduced by one pole.
The rated operational currents apply to each pole.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/141
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW

■ Overview
More information
Homepage, see www.siemens.com/sirius TIA Selection Tool Cloud (TST Cloud), see
Industry Mall, see www.siemens.com/product?3RA23_3RT1 www.siemens.com/tstcloud/?node=LoadFeeder
Conversion tool, see www.siemens.com/conversion-tool Guide of use for contactors in safety applications, see
https://support.industry.siemens.com/cs/ww/en/view/109807687

The 3RA23 reversing contactor assemblies in sizes S00 to S3 Complete 3RA23 reversing contactor assemblies
3

can be ordered as follows:


The 3RA23 reversing contactor assemblies of size S00 to S3
• Fully wired and tested, with mechanical and electrical each consist of two contactors with the same power, with one
interlock, see page 3/149 onwards. NC contact (S00) or one NO contact and one NC contact
• For all individual parts for customer assembly, see page 3/69 (S0 to S3) in the basic unit. The contactors are mechanically
onwards. and electrically interlocked (NC contact interlock).
The 3RA23 reversing contactor assemblies have screw 3RU2 overload relays (see page 7/89 onwards) or 3RB3 overload
terminals or spring-loaded terminals (main and control circuits) relays (see page 7/102 onwards) for contactor mounting or stand-
and are suitable for screw fixing and snap-on mounting on alone installation, SIMOCODE pro 3UF7 motor management and
TH 35 DIN rails. control devices (see page 10/12 onwards) or 3RN2 thermistor
motor protection relays (see page 10/136 onwards) can be used
for motor protection.
3RA23 reversing contactor assemblies with voltage tap-off
The reversing contactor assemblies with voltage tap-off
(see pages 3/149 to 3/152) are required for mounting the
function modules for connection to the controller via the IO-Link
or AS-Interface communications systems. The 3RA27 function
modules must be ordered separately, see page 3/101.
For more information on IO-Link and AS-Interface, see
"Industrial communication", page 2/1 onwards.

3/142 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW
Sizes S00 to S3
Rated data for AC-3/AC-3e Size Type
at AC 50 Hz 400 V
Rating Operational current Contactor Assembly kit Fully wired and tested
P Ie (see page 3/47 onwards) (see page 3/104) reversing contactor
assemblies
kW A
Screw terminals

3
3 7 S00-S00 3RT2015-1...2 3RA2913-2AA1 3RA2315-8XB30-1...
4 9 3RT2016-1...2 3RA2913-2AA1 3RA2316-8XB30-1...
5.5 12 3RT2017-1...2 3RA2913-2AA1 3RA2317-8XB30-1...
7.5 16 3RT2018-1...2 3RA2913-2AA1 3RA2318-8XB30-1...
5.5 12 S0-S0 3RT2024-1...0 3RA2923-2AA1 3RA2324-8XB30-1...
7.5 17 3RT2025-1...0 3RA2923-2AA1 3RA2325-8XB30-1...
11 25 3RT2026-1...0 3RA2923-2AA1 3RA2326-8XB30-1...
15 32 3RT2027-1...0 3RA2923-2AA1 3RA2327-8XB30-1...
18.5 38 3RT2028-1...0 3RA2923-2AA1 3RA2328-8XB30-1...
18.5 41 S2-S2 3RT2035-1...0 3RA2933-2AA1 3RA2335-8XB30-1...
22 51 3RT2036-1...0 3RA2933-2AA1 3RA2336-8XB30-1...
30 65 3RT2037-1...0 3RA2933-2AA1 3RA2337-8XB30-1...
37 80 3RT2038-1...0 3RA2933-2AA1 3RA2338-8XB30-1...
37 80 S3-S3 3RT2045-1...0 3RA2943-2AA1 3RA2345-8XB30-1...
45 95 3RT2046-1...0 3RA2943-2AA1 3RA2346-8XB30-1...
55 110 3RT2047-1...0 3RA2943-2AA1 3RA2347-8XB30-1...
Spring-loaded terminals

3 7 S00-S00 3RT2015-2...2 3RA2913-2AA2 3RA2315-8XB30-2...


4 9 3RT2016-2...2 3RA2913-2AA2 3RA2316-8XB30-2...
5.5 12 3RT2017-2...2 3RA2913-2AA2 3RA2317-8XB30-2...
7.5 16 3RT2018-2...2 3RA2913-2AA2 3RA2318-8XB30-2...
5.5 12 S0-S0 3RT2024-2...0 3RA2923-2AA2 3RA2324-8XB30-2...
7.5 17 3RT2025-2...0 3RA2923-2AA2 3RA2325-8XB30-2...
11 25 3RT2026-2...0 3RA2923-2AA2 3RA2326-8XB30-2...
15 32 3RT2027-2...0 3RA2923-2AA2 3RA2327-8XB30-2...
18.5 38 3RT2028-2...0 3RA2923-2AA2 3RA2328-8XB30-2...

Article number scheme


Product versions Article number
SIRIUS reversing contactor assembly 3RA23 @ @ – @ @ @ @ @ – @ @ @ @
Size of the contactor e.g. 4 = S3 @
Rating dependent on size e.g. 5 = 37 kW for size S3 @
Type of overload relay e.g. 8X = Without @@
Assembly e.g. E = Communication-capable installation @
Interlock e.g. 3 = Mechanical and electrical @
Free auxiliary switches e.g. 0 = S3: 2 NO total @
Type of electrical connection e.g. 1 = Screw terminals (main and auxiliary circuits) @
Operating range/solenoid coil circuit e.g. A = AC standard/without coil circuit @
Rated control supply voltage e.g. L2 = 230 V AC, 50/60 Hz @@
Example 3RA23 4 5 – 8 X E 3 0 – 1 A L 2
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

Siemens IC 10 · 2023 3/143


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW
Fully wired and tested reversing contactor assemblies · Size S00-S00 · Up to 7.5 kW
The figure shows the version with screw terminals

9
3

5
7
1 4
2

IC01_00621c
10
10
3

8
9
6
6
6

6
6

Mountable accessories (optional) Complete reversing contactor assembly


To be ordered separately Type Page Individual parts Type Page
Q11 Q12
6 Auxiliary switch, front1) 3RH2911 3/87 ... 3/89 1 2 Contactors, 3 kW 3RT2015 3RT2015 3/47, 3/52, 3/53
7 Auxiliary switch, lateral 3RH2921 3/91 1 2 Contactors, 4 kW 3RT2016 3RT2016 3/47, 3/52, 3/53
8 Surge suppressor 3RT2916 3/97, 3/98 1 2 Contactors, 5.5 kW 3RT2017 3RT2017 3/47, 3/52, 3/53
9 Solder pin adapter 3RT1916-4KA1 3/111 1 2 Contactors, 7.5 kW 3RT2018 3RT2018 3/47, 3/52, 3/53
10 Function module for connection to 3RA271.-1BA00 3/101 3 ... 5 Assembly kit 3RA2913-2AA1 3/104
the control system comprising:
3 Mechanical interlock2)
4 Two connecting clips for two contactors2)
5 Wiring modules on the top and bottom for
connecting the main current paths, electrical
interlock included3), interruptible (NC contact
interlock)

1) Auxiliary switch according to EN 50005 must be used. For complete reversing contactor assemblies, see page 3/149.
2)
The parts 3 and 4 can only be ordered together as 3RA2912-2H
mechanical connectors.
3)
3RT201. contactors with one NC contact in the basic unit are required for
the electrical interlock. An additional NO contact is required for
momentary-contact operation.

3/144 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW
Fully wired and tested reversing contactor assemblies · Size S0-S0 · Up to 18.5 kW
The figure shows the version with screw terminals

3
1
7
4 2

IC01_00622b
9
9 3

8 5

6
6 6

6
6

Mountable accessories (optional) Complete reversing contactor assembly


To be ordered separately Type Page Individual parts Type Page
Q11 Q12
6 Auxiliary switch, front 3RH2911 3/87 ... 3/89 1 2 Contactors, 5.5 kW 3RT2024 3RT2024 3/48, 3/56, 3/57
7 Auxiliary switch, lateral 3RH2921 3/91 1 2 Contactors, 7.5 kW 3RT2025 3RT2025 3/48, 3/56, 3/57
8 Surge suppressor 3RT2926 3/97, 3/98 1 2 Contactors, 11 kW 3RT2026 3RT2026 3/48, 3/56, 3/57
9 Function module for connection to 3RA271.-1BA00 3/101 1 2 Contactors, 15 kW 3RT2027 3RT2027 3/48, 3/56, 3/57
the control system Contactors, 18.5 kW 3RT2028 3RT2028 3/48, 3/56, 3/57
1 2
3 ... 5 Assembly kit 3RA2923-2AA1 3/104
comprising:
1)
3 Mechanical interlock
4 Two connecting clips for two contactors1)
5 Wiring modules on the top and bottom for
connecting the main current paths, electrical
interlock included (NC contact interlock)

1)
The parts 3 and 4 can only be ordered together as 3RA2922-2H For complete reversing contactor assemblies, see page 3/150.
mechanical connectors.

Siemens IC 10 · 2023 3/145


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW
Fully wired and tested reversing contactor assemblies · Size S2-S2 · Up to 37 kW
The figure shows the version with screw terminals
3

3
1
5 2
7

IC01_00623b
9

8 4
6
6
6

6
6

Mountable accessories (optional) Complete reversing contactor assembly


To be ordered separately Type Page Individual parts Type Page
Q11 Q12
6 Auxiliary switch, front 3RH2911 3/87 ... 3/89 1 2 Contactors, 18.5 kW 3RT2035 3RT2035 3/50, 3/61
7 Auxiliary switch, lateral 3RH2921 3/91 1 2 Contactors, 22 kW 3RT2036 3RT2036 3/50, 3/61
8 Surge suppressor 3RT2936 3/97, 3/98 1 2 Contactors, 30 kW 3RT2037 3RT2037 3/50, 3/61
9 Function module for connection to 3RA271.-1BA00 3/101 1 2 Contactors, 37 kW 3RT2038 3RT2038 3/50, 3/61
the control system Assembly kit 3RA2933-2AA1 3/104
3 4
comprising:
3 Two connectors for two contactors
4 Wiring modules on the top and bottom
for connecting the main and auxiliary circuits,
electrical interlock included (NC contact interlock)
5 Mechanical interlock 3RA2934-2B 3/108

For complete reversing contactor assemblies, see page 3/151.

3/146 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW
Fully wired and tested reversing contactor assemblies · Size S3-S3 · Up to 55 kW
The figure shows the version with screw terminals

3
1

3 2

5
7
9

IC01_00624d
10
10

8 4

6
6
6

6
6

Mountable accessories (optional) Complete reversing contactor assembly


To be ordered separately Type Page Individual parts Type Page
Q11 Q12
6 Auxiliary switch, front 3RH2911 3/87 ... 3/89 1 2 Contactors, 37 kW 3RT2045 3RT2045 3/51, 3/63
7 Auxiliary switch, lateral 3RH2921 3/91 1 2 Contactors, 45 kW 3RT2046 3RT2046 3/51, 3/63
8 Surge suppressor (varistor, 3RT2936 3/97, 3/98 1 2 Contactors, 55 kW 3RT2047 3RT2047 3/51, 3/63
diode assembly) Assembly kit 3RA2943-2AA1 3/104
3 4
9 Surge suppressor 3RT2946 3/97 comprising:
(RC element) Two connectors for two contactors
3
10 Function module for connection 3RA271.-1BA00 3/101 4 Wiring modules on the top and bottom
to the control system for connecting the main and auxiliary circuits,
(the associated module electrical interlock included (NC contact interlock)
connectors 3RA2711-0EE17 Mechanical interlock 3RA2934-2B 3/108
must be ordered separately,
5
see page 3/102)

For complete reversing contactor assemblies, see page 3/152.

Siemens IC 10 · 2023 3/147


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW

■ Benefits
Using wiring kits for reversing contactor assemblies has the Connecting combs for screw terminals also result in:
following advantages: • Prevention of wiring errors in the control circuit
• Notable reduction of wiring in the control circuit • Reduction of testing costs
• Integrated mechanical interlock for sizes S00 to S3 • Ready-jumpered actuation of the auxiliary switches and
• Prevention of wiring errors in the main circuit the frame (A2)
• Integrated electrical interlocking
3

■ Accessories
Selecting the auxiliary switches Surge suppression
The following points should be noted: Sizes S00 to S3
Size S00 All reversing contactor assemblies can be fitted with
• For maintained-contact operation: RC elements or varistors for damping switching overvoltages
Use contactors with an NC contact in the basic unit for in the coil.
the electrical interlock. As with the individual contactors, the surge suppressors can
• For momentary-contact operation: either be plugged onto the top of the contactors (S00) or be
Use contactors with an NC contact in the basic unit for the plugged into the front of the contactors (S0 to S3).
electrical interlock; in addition, an auxiliary switch with at least
one NO contact for self-locking is required per contactor.
Sizes S0 to S3
• For maintained-contact operation:
The contactors have two integrated auxiliary contacts
(1 NO contact + 1 NC contact); the NC contact can be
used for electrical interlocking.
• For momentary-contact operation:
Electrical interlock as for maintained-contact operation;
the NO contact in the basic unit can be used for the latching.

■ Technical specifications
More information
Technical specifications, see System Manual for modular system, see
https://support.industry.siemens.com/cs/ww/en/ps/16146/td https://support.industry.siemens.com/cs/ww/en/view/60311318
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16146/faq Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60306557
Application Manual - Switching devices with IE3 and IE4 motors, see
https://support.industry.siemens.com/cs/ww/en/view/94770820
Guide of use for contactors in safety applications, see
https://support.industry.siemens.com/cs/ww/en/view/109807687

The technical specifications are the same as for the individual


contactors (see page 3/25 onwards).

3/148 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW

■ Selection and ordering data


Fully wired and tested reversing contactor assemblies1) · Size S00-S00 · Up to 7.5 kW
AC operation or DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RA231.-8XB30-1A.0 3RA231.-8XE30-1BB4 3RA231.-8XB30-2A.0
Rated data AC-3 and AC-3e Rated control Screw terminals Spring-loaded
Operational Ratings of three-phase motors supply voltage terminals
current Ie up to at 50 Hz and 60 Hz Us Article No. Price Article No. Price
400 V 230 V 400 V 690 V per PU per PU
A kW kW kW V
AC operation, 50/60 Hz
7 2.2 3 4 24 AC 3RA2315-8XB30-1AB0 3RA2315-8XB30-2AB0
110 AC 3RA2315-8XB30-1AF0 3RA2315-8XB30-2AF0
230 AC 3RA2315-8XB30-1AP0 3RA2315-8XB30-2AP0
9 3 4 5.5 24 AC 3RA2316-8XB30-1AB0 3RA2316-8XB30-2AB0
110 AC 3RA2316-8XB30-1AF0 3RA2316-8XB30-2AF0
230 AC 3RA2316-8XB30-1AP0 3RA2316-8XB30-2AP0
12 3 5.5 5.5 24 AC 3RA2317-8XB30-1AB0 3RA2317-8XB30-2AB0
110 AC 3RA2317-8XB30-1AF0 3RA2317-8XB30-2AF0
230 AC 3RA2317-8XB30-1AP0 3RA2317-8XB30-2AP0
16 4 7.5 7.5 24 AC 3RA2318-8XB30-1AB0 3RA2318-8XB30-2AB0
110 AC 3RA2318-8XB30-1AF0 3RA2318-8XB30-2AF0
230 AC 3RA2318-8XB30-1AP0 3RA2318-8XB30-2AP0
DC operation
7 2.2 3 4 24 DC 3RA2315-8XB30-1BB4 3RA2315-8XB30-2BB4
9 3 4 5.5 24 DC 3RA2316-8XB30-1BB4 3RA2316-8XB30-2BB4
12 3 5.5 5.5 24 DC 3RA2317-8XB30-1BB4 3RA2317-8XB30-2BB4
16 4 7.5 7.5 24 DC 3RA2318-8XB30-1BB4 3RA2318-8XB30-2BB4
With voltage tap-off
7 2.2 3 4 24 DC 3RA2315-8XE30-1BB4 3RA2315-8XE30-2BB4
9 3 4 5.5 24 DC 3RA2316-8XE30-1BB4 3RA2316-8XE30-2BB4
12 3 5.5 5.5 24 DC 3RA2317-8XE30-1BB4 3RA2317-8XE30-2BB4
16 4 7.5 7.5 24 DC 3RA2318-8XE30-1BB4 3RA2318-8XE30-2BB4
1)
The contactors integrated in the reversing contactor assemblies have no Representation of the complete reversing contactor assemblies
unassigned auxiliary contacts. When used with a voltage tap-off and with optionally mountable accessories, see page 3/144.
function module, the auxiliary contacts are unassigned.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/149
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
Fully wired and tested reversing contactor assemblies · Size S0-S0 · Up to 18.5 kW
AC operation or DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RA232.-8XB30-1A.2 3RA2324-8XE30-1BB4 3RA232.-8XB30-2A.2


Rated data AC-3 and AC-3e Rated control Screw terminals Spring-loaded
Operational Ratings of three-phase motors supply voltage terminals
current Ie up to at 50 Hz and 60 Hz Us
Article No. Price Article No. Price
400 V 230 V 400 V 690 V per PU per PU
A kW kW kW V
AC operation, 50/60 Hz
12 3 5.5 7.5 24 AC 3RA2324-8XB30-1AC2 3RA2324-8XB30-2AC2
110 AC 3RA2324-8XB30-1AG2 3RA2324-8XB30-2AG2
230 AC 3RA2324-8XB30-1AL2 3RA2324-8XB30-2AL2
17 4 7.5 11 24 AC 3RA2325-8XB30-1AC2 3RA2325-8XB30-2AC2
110 AC 3RA2325-8XB30-1AG2 3RA2325-8XB30-2AG2
230 AC 3RA2325-8XB30-1AL2 3RA2325-8XB30-2AL2
25 5.5 11 11 24 AC 3RA2326-8XB30-1AC2 3RA2326-8XB30-2AC2
110 AC 3RA2326-8XB30-1AG2 3RA2326-8XB30-2AG2
230 AC 3RA2326-8XB30-1AL2 3RA2326-8XB30-2AL2
32 7.5 15 18.5 24 AC 3RA2327-8XB30-1AC2 3RA2327-8XB30-2AC2
110 AC 3RA2327-8XB30-1AG2 3RA2327-8XB30-2AG2
230 AC 3RA2327-8XB30-1AL2 3RA2327-8XB30-2AL2
38 11 18.5 18.5 24 AC 3RA2328-8XB30-1AC2 3RA2328-8XB30-2AC2
110 AC 3RA2328-8XB30-1AG2 3RA2328-8XB30-2AG2
230 AC 3RA2328-8XB30-1AL2 3RA2328-8XB30-2AL2
DC operation
12 3 5.5 7.5 24 DC 3RA2324-8XB30-1BB4 3RA2324-8XB30-2BB4
17 4 7.5 11 24 DC 3RA2325-8XB30-1BB4 3RA2325-8XB30-2BB4
25 5.5 11 11 24 DC 3RA2326-8XB30-1BB4 3RA2326-8XB30-2BB4
32 7.5 15 18.5 24 DC 3RA2327-8XB30-1BB4 3RA2327-8XB30-2BB4
38 11 18.5 18.5 24 DC 3RA2328-8XB30-1BB4 3RA2328-8XB30-2BB4
With voltage tap-off
12 3 5.5 7.5 24 DC 3RA2324-8XE30-1BB4 3RA2324-8XE30-2BB4
17 4 7.5 11 24 DC 3RA2325-8XE30-1BB4 3RA2325-8XE30-2BB4
25 5.5 11 11 24 DC 3RA2326-8XE30-1BB4 3RA2326-8XE30-2BB4
32 7.5 15 18.5 24 DC 3RA2327-8XE30-1BB4 3RA2327-8XE30-2BB4
38 11 18.5 18.5 24 DC 3RA2328-8XE30-1BB4 3RA2328-8XE30-2BB4

Representation of the complete reversing contactor assemblies


with optionally mountable accessories, see page 3/145.

* You can order this quantity or a multiple thereof.


3/150 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW
Fully wired and tested reversing contactor assemblies · Size S2-S2 · Up to 37 kW
AC operation or AC/DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RA233.-8XB30-1A.2 3RA233.-8XE30-1NB3
Rated data AC-3 and AC-3e Rated control Screw terminals Spring-loaded
Operational Ratings of three-phase motors supply voltage terminals
current Ie up to at 50 Hz and 60 Hz Us
Article No. Price Article No. Price
400 V 230 V 400 V 690 V per PU per PU
A kW kW kW V
AC operation, 50/60 Hz
41 11 18.5 22 110 AC 3RA2335-8XB30-1AG2 --
230 AC 3RA2335-8XB30-1AL2 --
51 15 22 22 110 AC 3RA2336-8XB30-1AG2 --
230 AC 3RA2336-8XB30-1AL2 --
65 18.5 30 37 110 AC 3RA2337-8XB30-1AG2 --
230 AC 3RA2337-8XB30-1AL2 --
80 22 37 45 110 AC 3RA2338-8XB30-1AG2 --
230 AC 3RA2338-8XB30-1AL2 --
AC/DC operation
With integrated coil circuit
(varistor integrated in electronics at the factory)
41 11 18.5 22 20 ... 33 AC/DC 3RA2335-8XB30-1NB3 --
51 15 22 22 20 ... 33 AC/DC 3RA2336-8XB30-1NB3 --
65 18.5 30 37 20 ... 33 AC/DC 3RA2337-8XB30-1NB3 --
80 22 37 45 20 ... 33 AC/DC 3RA2338-8XB30-1NB3 --
With voltage tap-off
41 11 18.5 22 20 ... 33 AC/DC 3RA2335-8XE30-1NB3 --
51 15 22 22 20 ... 33 AC/DC 3RA2336-8XE30-1NB3 --
65 18.5 30 37 20 ... 33 AC/DC 3RA2337-8XE30-1NB3 --
80 22 37 45 20 ... 33 AC/DC 3RA2338-8XE30-1NB3 --

Representation of the complete reversing contactor assemblies


with optionally mountable accessories, see page 3/146.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/151
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW IE3 ready IE4 ready IE3/IE4 ready
AC-3e
Fully wired and tested reversing contactor assemblies · Size S3-S3 · Up to 55 kW
AC operation or AC/DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RA234.-8XB30-1A.2 3RA234.-8XE30-1NB3
Rated data AC-3 and AC-3e Rated control Screw terminals Spring-loaded
Operational Ratings of three-phase motors supply voltage terminals
current Ie up to at 50 Hz and 60 Hz Us1) Article No. Price Article No. Price
400 V 230 V 400 V 690 V per PU per PU
A kW kW kW V
AC operation, 50/60 Hz
80 22 37 55 110 AC 3RA2345-8XB30-1AG2 --
230 AC 3RA2345-8XB30-1AL2 --
95 22 45 75 110 AC 3RA2346-8XB30-1AG2 --
230 AC 3RA2346-8XB30-1AL2 --
110 30 55 75 110 AC 3RA2347-8XB30-1AG2 --
230 AC 3RA2347-8XB30-1AL2 --
AC/DC operation
With integrated coil circuit
(varistor integrated in electronics at the factory)
80 22 37 55 20 ... 33 AC/DC 3RA2345-8XB30-1NB3 --
95 22 45 75 20 ... 33 AC/DC 3RA2346-8XB30-1NB3 --
110 30 55 75 20 ... 33 AC/DC 3RA2347-8XB30-1NB3 --
With voltage tap-off 1)
80 22 37 55 20 ... 33 AC/DC 3RA2345-8XE30-1NB3 --
95 22 45 75 20 ... 33 AC/DC 3RA2346-8XE30-1NB3 --
110 30 55 75 20 ... 33 AC/DC 3RA2347-8XE30-1NB3 --
1)
The associated module connectors 3RA2711-0EE17 for the 3RA271. Representation of the complete reversing contactor assemblies
function modules must be ordered separately, see page 3/102. with optionally mountable accessories, see page 3/147.

* You can order this quantity or a multiple thereof.


3/152 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
Reversing contactor assemblies consisting of SIRIUS 3RT1 and 3TF6 contactors, up to 335 kW

■ Overview
The individual parts for the reversing contactor assemblies for
customer assembly must be ordered separately. More information

• 3RT1 contactors (see page 3/64 onwards) and Homepage, see www.siemens.com/sirius
3RT12 and 3TF6 vacuum contactors (see page 3/130 Industry Mall, see www.siemens.com/product?3RA23_3RT1
onwards): Guide of use for contactors in safety applications, see
The operating times of the individual contactors are rated in https://support.industry.siemens.com/cs/ww/en/view/109807687
such a way that no overlapping of the contact connection and

3
the arcing time between two contactors can occur on
reversing, provided they are interlocked by way of their
auxiliary switches (NC contact interlock) and the mechanical
interlock.
For assemblies with AC operation and 50/60 Hz, a dead
interval of 50 ms must be provided when used with voltages
over 500 V; a dead interval of 30 ms is recommended for use
with voltages up to and including 400 V. These dead times do
not apply to assemblies with DC operation.
The operating times of the individual contactors are not
affected by the mechanical interlock.
• Mechanical interlocks
- 3RT1 contactors: see page 3/108
- 3TF68 vacuum contactors: Locking device for mechanical
interlock, see page 3/135.
• Wiring kits consisting of wiring modules on the top and bottom
- 3RT1 contactors: see page 3/104
- 3TF68 vacuum contactors: see page 3/135
• Base plates
- 3RT1 contactors: see page 3/113
- 3TF68 vacuum contactors: see page 3/135
Additional components
• For momentary-contact operation: auxiliary switch
(NO contact) for self-locking
• 3RB2 overload relays (see page 7/114 onwards),
SIMOCODE pro 3UF7 motor management and control
devices (see page 10/12 onwards) or 3RN2 thermistor motor
protection relays (see page 10/136 onwards) can be used for
overload protection.

Siemens IC 10 · 2023 3/153


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
Reversing contactor assemblies consisting of SIRIUS 3RT1 and 3TF6 contactors, up to 335 kW
Reversing contactor assemblies for customer assembly · Size S6-S6 · Up to 90 kW

6
3

2
8
4

8
5

IC01_00583c
7
7

Mountable accessories (optional) Reversing contactor assembly for customer assembly


To be ordered separately Type Page Individual parts Type Page
Q11 Q12
7 Auxiliary switch, front 3RH1921 3/90 1 2 Contactors, 55 kW 3RT1054 3RT1054 3/64 ... 3/66
8 Auxiliary switch, lateral 3RH1921 3/92 1 2 Contactors, 75 kW 3RT1055 3RT1055 3/64 ... 3/66
1 2 Contactors, 90 kW 3RT1056 3RT1056 3/64 ... 3/66
3 Assembly kit 3RA1953-2A 3/104
consisting of:
Wiring modules on the top and bottom
for contactors without box terminals
for connecting the main and auxiliary
circuits, electrical interlock included
(NC contact interlock)
4 Two connectors for two contactors 3RA1932-2D 3/108
5 Mechanical interlock 3RA1954-2A 3/108
6 Base plate for reversing contactor 3RA1952-2A 3/113
assemblies

3/154 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
Reversing contactor assemblies consisting of SIRIUS 3RT1 and 3TF6 contactors, up to 335 kW
Reversing contactor assemblies for customer assembly · Size S10-S10 · Up to 160 kW

3
3
1

2
7

IC01_00584c
6
6

Mountable accessories (optional) Reversing contactor assembly for customer assembly


To be ordered separately Type Page Individual parts Type Page
Q11 Q12
6 Auxiliary switch, front 3RH1921 3/90 1 2 Contactors, 110 kW 3RT1.64 3RT1.64 3/64 ... 3/66,
3/130
7 Auxiliary switch, lateral 3RH1921 3/92 1 2 Contactors, 132 kW 3RT1.65 3RT1.65 3/64 ... 3/66,
3/130
1 2 Contactors, 160 kW 3RT1.66 3RT1.66 3/64 ... 3/66,
3/130
3 Assembly kit 3RA1963-2A 3/104
consisting of:
Wiring modules on the top and bottom
for contactors without box terminals
for connecting the main and auxiliary
circuits, electrical interlock included
(NC contact interlock)
4 Mechanical interlock 3RA1954-2A 3/108
5 Base plate for reversing contactor 3RA1962-2A 3/113
assemblies

Siemens IC 10 · 2023 3/155


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
Reversing contactor assemblies consisting of SIRIUS 3RT1 and 3TF6 contactors, up to 335 kW
Reversing contactor assemblies for customer assembly · Size S12-S12 · Up to 250 kW

5
3

3
1

IC01_00585c
6
6

Mountable accessories (optional) Reversing contactor assembly for customer assembly


To be ordered separately Type Page Individual parts Type Page
Q11 Q12
6 Auxiliary switch, front 3RH1921 3/90 1 2 Contactors, 200 kW 3RT1.75 3RT1.75 3/64 ... 3/66,
3/130
7 Auxiliary switch, lateral 3RH1921 3/92 1 2 Contactors, 250 kW 3RT1.76 3RT1.76 3/64 ... 3/66,
3/130
3 Assembly kit 3RA1973-2A 3/104
consisting of:
Wiring modules on the top and bottom
for contactors without box terminals
for connecting the main and auxiliary
circuits, electrical interlock included
(NC contact interlock)
4 Mechanical interlock 3RA1954-2A 3/108
5 Base plate for reversing contactor 3RA1972-2A 3/113
assemblies

3/156 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Reversing contactor assemblies
Reversing contactor assemblies consisting of SIRIUS 3RT1 and 3TF6 contactors, up to 335 kW
Reversing contactor assemblies for customer assembly · Size 14-14 · Up to 335 kW

3
2

IC01_00779
2

Reversing contactor assembly for customer assembly


Individual parts Type Page
Q11 Q12
1 Vacuum contactors, 335 kW 3TF68 3TF68 3/131, 3/132
2 Assembly kit 3TX7680-1A 3/135
consisting of:
Wiring modules on the top and bottom
for connecting the main and auxiliary circuits,
electrical interlock included (NC contact interlock)
3 Locking device for mechanical interlock 3TX7686-1A 3/135
4 Base plate for reversing contactor assemblies 3TX7681-1A 3/135

Siemens IC 10 · 2023 3/157


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW

■ Overview
More information
Homepage, see www.siemens.com/sirius TIA Selection Tool Cloud (TST Cloud), see
Industry Mall, see www.siemens.com/product?3RA24_3RT www.siemens.com/tstcloud/?node=LoadFeeder
Conversion tool, see www.siemens.com/conversion-tool Guide of use for contactors in safety applications, see
https://support.industry.siemens.com/cs/ww/en/view/109807687

The 3RA24 contactor assemblies for star-delta (wye-delta) Surge suppression


3

starting in sizes S00 to S3 can be ordered as follows:


Surge suppression (varistor) is included in the 3RA28 function
• Fully wired and tested, with electrical and mechanical modules for star-delta (wye-delta) starting.
interlock, see page 3/167 onwards.
• For all individual parts for customer assembly, see page 3/69 Motor protection
onwards. 3RU2 overload relays (see page 7/89 onwards) or 3RB3
The 3RA24 contactor assemblies for star-delta (wye-delta) overload relays (see page 7/102 onwards) for contactor
starting have screw terminals or spring-loaded terminals mounting or stand-alone installation, SIMOCODE pro 3UF7
and are suitable for screw fixing and snap-on mounting on motor management and control devices (see page 10/12
TH 35 DIN rails. onwards) or 3RN2 thermistor motor protection relays (see
page 10/136 onwards) can be used for motor protection.
A base plate is also available for the size S2 and S3 assemblies.
The overload relay can either be mounted on the line contactor
A dead interval of 50 ms on reversing is already integrated in the or fitted separately. It must be set to 0.58 times the rated motor
3RA28 function module for star-delta (wye-delta) starting. current.
With the fully wired and tested 3RA24 contactor assemblies for SIRIUS 3RA28 function module for star-delta (wye-delta)
star-delta (wye-delta) starting, the auxiliary contacts included in starting
the basic units are unassigned.
The 3RA2816-0EW20 star-delta (wye-delta) function module
The 3RA24 contactor assemblies for star-delta (wye-delta) (see page 3/100) replaces the complete wiring in the control
starting are designed for standard applications. circuit and can be used in the voltage range from 24 to
Note: 240 V AC/DC. It is snapped onto the front of the contactor
assembly for star-delta (wye-delta) starting size S00, S0,
Contactor assemblies for star-delta (wye-delta) starting in S2 or S3.
special applications such as very heavy starting1) or star-delta
(wye-delta) starting of special motors must be customized. One function module comprises a complete module kit:
Help with designing such special applications is available from • Basic module with integrated control logic and time setting
our Technical Support, • Two coupling modules with corresponding connecting cables
www.siemens.com/support-request.
The scope of supply thus comprises a complete module kit for
one contactor assembly for star-delta (wye-delta) starting in size
S00, S0, S2 or S3, regardless of the connection method.
Data of the control circuit:
• Wide voltage range 24 to 240 V AC/DC
• Time setting range 0.5 to 60 s (3 selectable settings)
• Dead interval of 50 ms, non-adjustable
1)
For effective assistance from Technical Support, you must provide the
following details:
- Rated motor voltage,
- Rated motor current,
- Service factor, operating values
- Motor starting current factor
- Starting time
- Ambient temperature

3/158 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW
Complete units
Note:
The selection of contactor types refers to fused designs.
Rated data at 50 Hz 400 V AC Size Type
Rating Operational current Motor current Line/delta contactor Star contactor Fully wired and tested
P Ie contactor assemblies for
kW A A star-delta (wye-delta) starting

3
Screw terminals

5.5 12 9.5 ... 13.8 S00-S00-S00 3RT2015-1.... 3RT2015-1.... 3RA2415-8XF31-1...


7.5 16 12.1 ... 17 3RT2017-1.... 3RT2015-1.... 3RA2416-8XF31-1...
11 25 19 ... 25 3RT2018-1.... 3RT2016-1.... 3RA2417-8XF31-1...
11 25 19 ... 25 S0-S0-S0 3RT2024-1...0 3RT2024-1...0 3RA2423-8XF32-1...
15 32 24.1 ... 34 3RT2026-1...0 3RT2024-1...0 3RA2425-8XF32-1...
18.5 40 34.5 ... 40 3RT2026-1...0 3RT2024-1...0 3RA2425-8XF32-1...
22 50 31 ... 43 3RT2027-1...0 3RT2026-1...0 3RA2426-8XF32-1...
22/30 50 31 ... 43 S2-S2-S0 3RT2035-1...0 3RT2026-1...0 3RA2434-8XF32-1...
37 80 62.1 ... 77.8 3RT2035-1...0 3RT2027-1...0 3RA2435-8XF32-1...
45 86 69 ... 86 3RT2036-1...0 3RT2028-1...0 3RA2436-8XF32-1...
55 115 77.6 ... 108.6 S2-S2-S2 3RT2037-1...0 3RT2035-1...0 3RA2437-8XF32-1...
55 115 77.6 ... 108.6 S3-S3-S2 3RT2045-1...0 3RT2035-1...0 3RA2444-8XF32-1...
75 150 120.7 ... 150 3RT2045-1...0 3RT2036-1...0 3RA2445-8XF32-1...
90 160 86 ... 160 3RT2046-1...0 3RT2037-1...0 3RA2446-8XF32-1...
Spring-loaded terminals

5.5 12 9.5 ... 13.8 S00-S00-S00 3RT2015-2.... 3RT2015-2.... 3RA2415-8XF31-2...


7.5 16 12.1 ... 17 3RT2017-2.... 3RT2015-2.... 3RA2416-8XF31-2...
11 25 19 ... 25 3RT2018-2.... 3RT2016-2.... 3RA2417-8XF31-2...
11 25 19 ... 25 S0-S0-S0 3RT2024-2...0 3RT2024-2...0 3RA2423-8XF32-2...
15 32 24.1 ... 34 3RT2026-2...0 3RT2024-2...0 3RA2425-8XF32-2...
18.5 40 34.5 ... 40 3RT2026-2...0 3RT2024-2...0 3RA2425-8XF32-2...
22 50 31 ... 43 3RT2027-2...0 3RT2026-2...0 3RA2426-8XF32-2...

Article number scheme


Product versions Article number
SIRIUS contactor assembly for star-delta (wye-delta) starting 3RA24 @ @ – @ @ @ @ @ – @ @ @ @
Size of the contactor e.g. 4 = S3 @
Rating dependent on size e.g. 5 = 75 kW for size S3 @
Type of overload relay e.g. 8X = Without @@
Assembly e.g. F = Ready-assembled with function modules @
Interlock e.g. 3 = Mechanical and electrical @
Free auxiliary switches e.g. 2 = S3: 3 NO + 3 NC total @
Type of electrical connection e.g. 1 = Screw terminals (main and auxiliary circuits) @
Operating range/solenoid coil circuit e.g. A = AC standard/without coil circuit @
Rated control supply voltage e.g. L2 = 230 V AC, 50/60 Hz @@
Example 3RA24 4 5 – 8 X F 3 2 – 1 A L 2
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

Siemens IC 10 · 2023 3/159


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW
Fully wired and tested contactor assemblies for star-delta (wye-delta) starting · Size S00-S00-S00 · Up to 11 kW
The figure shows the version with screw terminals

9
3

2
1 5 3

IC01_00625c
4

Mountable accessories (optional) Complete contactor assembly for star-delta (wye-delta) starting
To be ordered separately Type Page Individual parts Type Page
Q112) Q13 Q12
9 3-phase infeed terminal1) 3RA2913-3K 3/110 1 2 3 Contactors, 5.5 kW 3RT2015 3RT2015 3RT2015 3/47, 3/52
1 2 3 Contactors, 7.5 kW 3RT2017 3RT2017 3RT2015 3/47, 3/52
1 2 3 Contactors, 11 kW 3RT2018 3RT2018 3RT2016 3/47, 3/52
4 ... 7 Assembly kit S00-S00-S00 3RA2913-2BB1 3/105
comprising:
4 Mechanical interlock
5 Four connecting clips for three contactors
6 Wiring modules on top and bottom for
connecting the main and auxiliary circuits
7 Star jumper
8 Function modules for star-delta 3RA2816-0EW20 3/100
(wye-delta) starting

1)
Part 9 can only be mounted for contactors with screw terminals. Complete contactor assemblies for star-delta (wye-delta)
2)
The version with 1 NO is required for momentary-contact operation. starting, see page 3/167.

3/160 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW
Fully wired and tested contactor assemblies for star-delta (wye-delta) starting · Size S0-S0-S0 · Up to 22 kW
The figure shows the version with screw terminals

10
9 6

3
7

2
3
1

IC01_00626c
4

Mountable accessories (optional) Complete contactor assembly for star-delta (wye-delta) starting
To be ordered separately Type Page Individual parts Type Page
Q11 Q13 Q12
9 3-phase infeed terminal1) 3RV2925-5AB 3/110 1 2 3 Contactors, 11 kW 3RT2024 3RT2024 3RT2024 3/48, 3/56
10 3-phase busbar1) 3RV1915-1AB 3/110 1 2 3 Contactors, 15/18.5 kW 3RT2026 3RT2026 3RT2024 3/48, 3/56
1 2 3 Contactors, 22 kW 3RT2027 3RT2027 3RT2026 3/48, 3/56
4 ... 7 Assembly kit S0-S0-S0 3RA2923-2BB1 3/105
comprising:
4 Mechanical interlock
5 Four connecting clips for three contactors
6 Wiring modules on top and bottom for
connecting the main and auxiliary circuits
7 Star jumper
8 Function modules for star- 3RA2816-0EW20 3/100
delta (wye-delta) starting

1)
The parts 9 and 10 can only be mounted for contactors with screw Complete contactor assemblies for star-delta (wye-delta)
terminals, the wiring modules 6 must be removed beforehand. starting, see page 3/168.

Siemens IC 10 · 2023 3/161


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW
Fully wired and tested contactor assemblies for star-delta (wye-delta) starting · Size S2-S2-S01) · Up to 45 kW and S2-S2-S2 · 55 kW
The figure shows the version with screw terminals in S2-S2-S2

10

5
3

11

2
4
3
1
8

IC01_00627c
9
5

Mountable accessories (optional) Complete contactor assembly for star-delta (wye-delta) starting
To be ordered separately Type Page Individual parts Type Page
Q11 Q13 Q12
11 3-phase infeed terminal 3RV2935-5A 3/110 1 2 3 Contactors, 22/30 kW 3RT2035 3RT2035 3RT2026 3/50, 3/61
1 2 3 Contactors, 37 kW 3RT2035 3RT2035 3RT2027 3/50, 3/61
1 2 3 Contactors, 45 kW 3RT2036 3RT2036 3RT2028 3/50, 3/61
1 2 3 Contactors, 55 kW 3RT2037 3RT2037 3RT2035 3/50, 3/61
4 ... 7 Assembly kit S2-S2-S2 3RA2933-2BB1 3/105
comprising:
4 Four connectors for three contactors (not required for fully
pre-wired contactor assemblies for star-delta (wye-delta) starting)
5 Wiring modules on top and bottom for
connecting the main and auxiliary circuits
6 Star jumper S2
7 Cable for connecting the A2 coil contact of the line contactor
with the A2 coil contact of the delta contactor
(not shown in the drawing)
8 Mechanical interlock 3RA2934-2B 3/108
9 Function modules for star-delta 3RA2816-0EW20 3/100
(wye-delta) starting
10 Base plate star-delta 3RA2932-2F 3/113
(wye-delta)

1) Complete contactor assembly for star-delta (wye-delta) starting in size Complete contactor assemblies for star-delta (wye-delta)
S2-S2-S0 (not shown): The 3RA2933-2C assembly kit is to be used here, starting, see page 3/169.
see page 3/105.

3/162 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW
Fully wired and tested contactor assemblies for star-delta (wye-delta) starting · Size S3-S3-S21) · Up to 90 kW

10
5

11

3
1
2
6
4
3

IC01_00628c
9 5
9

Mountable accessories (optional) Complete contactor assembly for star-delta (wye-delta) starting
To be ordered separately Type Page Individual parts Type Page
Q11 Q13 Q12
11 1-phase infeed terminal 3RA2943-3L 3/110 1 2 3 Contactors, 55 kW 3RT2045 3RT2045 3RT2035 3/51, 3/63
(three units are required) Contactors, 75 kW 3RT2045 3RT2045 3RT2036 3/51, 3/63
1 2 3
1 2 3 Contactors, 90 kW 3RT2046 3RT2046 3RT2037 3/51, 3/63
4 ... 7 Assembly kit S3-S3-S2 3RA2943-2C 3/105
comprising:
4 Two connectors for three contactors (not required for fully
pre-wired contactor assemblies for star-delta (wye-delta) starting)
5 Wiring modules on top and bottom (S3-S2) for connecting the
main and auxiliary circuits and a cable set for the auxiliary circuit
6 Star jumper S2
7 Cable for connecting the A2 coil contact of the line contactor
with the A2 coil contact of the delta contactor
(not shown in the drawing)
8 Mechanical interlock 3RA2934-2B 3/108
9 Function modules for star-delta 3RA2816-0EW20 3/100
(wye-delta) starting
10 Base plate star-delta 3RA2942-2F 3/113
(wye-delta)

1)
Contactor assembly for star-delta (wye-delta) starting for customer Complete contactor assemblies for star-delta (wye-delta)
assembly in size S3-S3-S3 (not shown): The 3RA2943-2BB. assembly kit is starting, see page 3/170.
to be used here, see page 3/105.

Siemens IC 10 · 2023 3/163


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW

■ Technical specifications
More information
Technical specifications, see Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/ps/16150/td https://support.industry.siemens.com/cs/ww/en/view/60306557
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16150/faq Application Manual - Switching devices with IE3 and IE4 motors, see
System Manual for modular system, see https://support.industry.siemens.com/cs/ww/en/view/94770820
https://support.industry.siemens.com/cs/ww/en/view/60311318 Guide of use for contactors in safety applications, see
https://support.industry.siemens.com/cs/ww/en/view/109807687
3

Unless otherwise indicated below, the technical specifications


correspond to those of the 3RT individual contactors
(see page 3/25 onwards) and 3RU2 overload relays
(see page 7/85 onwards).
Type 3RA2415 3RA2416 3RA2417 3RA2423 3RA2425 3RA2426
Sizes S00-S00-S00 S00-S00-S00 S00-S00-S00 S0-S0-S0 S0-S0-S0 S0-S0-S0
General data
Dimensions (W x H x D) with function module
• AC operation
- Screw terminals mm 135 x 68 x 145 135 x 101 x 171
H

- Spring-loaded terminals mm 135 x 84 x 145 135 x 114 x 171


• DC operation
D

W
- Screw terminals mm 135 x 68 x 145 135 x 101 x 181
- Spring-loaded terminals mm 135 x 84 x 145 135 x 114 x 181
Individual contactors
• Q11 line contactor Type 3RT2015 3RT2017 3RT2018 3RT2024 3RT2026 3RT2027
• Q13 delta contactor Type 3RT2015 3RT2017 3RT2018 3RT2024 3RT2026 3RT2027
• Q12 star contactor Type 3RT2015 3RT2015 3RT2016 3RT2024 3RT2024 3RT2026
Mechanical endurance Operating 3 million
cycles
Unassigned auxiliary contacts of the individual For circuit diagrams of the control circuit, see
contactors Equipment Manual for contactors/contactor assemblies
Short-circuit protection
Main circuit without overload relays
Fuse links, operational class gG:
LV HRC, type 3NA; DIAZED, type 5SB; NEOZED,
type 5SE with single or double infeed
• Highest rated current of the fuse
according to IEC 60947-4-1
- Type of coordination "1" A 35 63 100 125
- Type of coordination "2" A 20 25 35 63
Auxiliary circuit
Short-circuit test
• With fuse links, operational class gG: A 10
DIAZED, type 5SB; NEOZED, type 5SE A 6 (up to Ik < 0.5 kA;  260 V),
with short-circuit current Ik = 1 kA according to if the auxiliary contact of the overload relay is connected in the contactor coil circuit
IEC 60947-5-1
• With miniature circuit breaker, C characteristic A 10
with short-circuit current Ik = 400 A A 6 (up to Ik < 0.5 kA;  260 V),
if the auxiliary contact of the overload relay is connected in the contactor coil circuit
Short-circuit protection with overload relay See Configuration Manual for load feeders

3/164 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW

Type 3RA2415 3RA2416 3RA2417 3RA2423 3RA2425 3RA2426


Sizes S00-S00-S00 S00-S00-S00 S00-S00-S00 S0-S0-S0 S0-S0-S0 S0-S0-S0
Rated data of the main contacts
Current-carrying capacity with reversing time
up to 10 s
• Rated operational current Ie at 400 V A 12 17 25 40 55
690 V A 6.9 9 20.8 22.5 35
• Rated power for three-phase at 230 V kW 3.3 4.7 7.2 12 16.6

3
motors at 50 Hz and 60 Hz 400 V kW 5.8 8.2 12.5 21 30.1
690 V kW 5.8 7.5 18 20.4 33
• Switching frequency with overload relay 1/h 15
Current-carrying capacity with reversing time
up to 15 s
• Rated operational current Ie at 400 V A 12 17 25 31 44
690 V A 6.9 9 20.8 22.5 35
• Rated power for three-phase at 230 V kW 3.3 4.7 7.2 9.4 13.8
motors at 50 Hz and 60 Hz 400 V kW 5.8 8.2 12.5 16.3 24
690 V kW 5.8 7.5 18 20.4 33
• Switching frequency with overload relay 1/h 15
Current-carrying capacity with reversing time
up to 20 s
• Rated operational current Ie at 400 V A 12 17 25 28 39
690 V A 6.9 9 20.8 22.5 35
• Rated power for three-phase at 230 V kW 3.3 4.7 7.2 8.5 12.2
motors at 50 Hz and 60 Hz 400 V kW 5.8 8.2 12.5 14.7 21.3
690 V kW 5.8 7.5 18 20.4 33
• Switching frequency with overload relay 1/h 15

Siemens IC 10 · 2023 3/165


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW

Type 3RA2434 3RA2435 3RA2436 3RA2437 3RA2444 3RA2445 3RA2446


Sizes S2-S2-S0 S2-S2-S0 S2-S2-S0 S2-S2-S2 S3-S3-S2 S3-S3-S2 S3-S3-S2
General data
Dimensions (W x H x D) with
function module
• AC and DC operation
H
- Screw terminals mm 177.5 x 142 x 223 220 x 180 x 244

D
W
3

Individual contactors
• Q11 line contactor Type 3RT2035 3RT2035 3RT2036 3RT2037 3RT2045 3RT2045 3RT2046
• Q13 delta contactor Type 3RT2035 3RT2035 3RT2036 3RT2037 3RT2045 3RT2045 3RT2046
• Q12 star contactor Type 3RT2026 3RT2027 3RT2028 3RT2035 3RT2035 3RT2036 3RT2037
Mechanical endurance Operat- 1 million
ing
cycles
Unassigned auxiliary contacts of the individual For circuit diagrams of the control circuit, see Equipment Manual.
contactors
Short-circuit protection
Main circuit without overload relays
Fuse links, operational class gG:
LV HRC, type 3NA; DIAZED, type 5SB; NEOZED,
type 5SE with single or double infeed
• Highest rated current of the fuse
according to IEC 60947-4-1
- Type of coordination "1" A 160 250
- Type of coordination "2" A 80 125 160
Auxiliary circuit
Short-circuit test
• With fuse links, operational class gG: A 10
DIAZED, type 5SB; NEOZED, type 5SE A 6 (up to Ik < 0.5 kA;  260 V),
with short-circuit current Ik = 1 kA if the auxiliary contact of the overload relay is connected in the contactor coil circuit
according to IEC 60947-5-1
• With miniature circuit breaker, C characteristic A 10
with short-circuit current Ik = 400 A A 6 (up to Ik < 0.5 kA;  260 V),
if the auxiliary contact of the overload relay is connected in the contactor coil circuit
Short-circuit protection with overload relay See Configuration Manual for load feeders On request
Rated data of the main contacts
Current-carrying capacity with reversing time
up to 10 s
• Rated operational current Ie at 400 V A On request
690 V A On request
• Rated power for three-phase at 230 V kW On request
motors at 50 Hz and 60 Hz 400 V kW On request
690 V kW On request
• Switching frequency with overload relay 1/h 15
Current-carrying capacity with reversing time
up to 15 s
• Rated operational current Ie at 400 V A On request
690 V A On request
• Rated power for three-phase at 230 V kW On request
motors at 50 Hz and 60 Hz 400 V kW On request
690 V kW On request
• Switching frequency with overload relay 1/h 15
Current-carrying capacity with reversing time
up to 20 s
• Rated operational current Ie at 400 V A On request
690 V A On request
• Rated power for three-phase at 230 V kW On request
motors at 50 Hz and 60 Hz 400 V kW On request
690 V kW On request
• Switching frequency with overload relay 1/h 15

3/166 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
IE3 ready IE4 ready IE3/IE4 ready SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW

■ Selection and ordering data


Fully wired and tested contactor assemblies for star-delta (wye-delta) starting · Size S00-S00-S00 · Up to 11 kW
AC operation or DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RA241.-8XF31-1A.0 3RA241.-8XF31-2A.0 3RA241.-8XE31-2BB4
Rated data AC-3 Rated control Screw terminals Spring-loaded
Operational Ratings of three-phase motors supply terminals
current Ie at 50 Hz and 60 Hz voltage Us Article No. Price Article No. Price
up to at per PU per PU
400 V 230 V 400 V 690 V
A kW kW kW V
AC operation, 50/60 Hz
12 3.3 5.5 9.2 24 AC 3RA2415-8XF31-1AB0 3RA2415-8XF31-2AB0
110 AC 3RA2415-8XF31-1AF0 3RA2415-8XF31-2AF0
230 AC 3RA2415-8XF31-1AP0 3RA2415-8XF31-2AP0
16 4.7 7.5 9.2 24 AC 3RA2416-8XF31-1AB0 3RA2416-8XF31-2AB0
110 AC 3RA2416-8XF31-1AF0 3RA2416-8XF31-2AF0
230 AC 3RA2416-8XF31-1AP0 3RA2416-8XF31-2AP0
25 5.5 11 11 24 AC 3RA2417-8XF31-1AB0 3RA2417-8XF31-2AB0
110 AC 3RA2417-8XF31-1AF0 3RA2417-8XF31-2AF0
230 AC 3RA2417-8XF31-1AP0 3RA2417-8XF31-2AP0
DC operation
12 3.3 5.5 9.2 24 DC 3RA2415-8XF31-1BB4 3RA2415-8XF31-2BB4
16 4.7 7.5 9.2 24 DC 3RA2416-8XF31-1BB4 3RA2416-8XF31-2BB4
25 5.5 11 11 24 DC 3RA2417-8XF31-1BB4 3RA2417-8XF31-2BB4
For IO-Link connection
12 3.3 5.5 9.2 24 DC 3RA2415-8XE31-1BB4 3RA2415-8XE31-2BB4
16 4.7 7.5 9.2 24 DC 3RA2416-8XE31-1BB4 3RA2416-8XE31-2BB4
25 5.5 11 11 24 DC 3RA2417-8XE31-1BB4 3RA2417-8XE31-2BB4
For AS-Interface integration
12 3.3 5.5 9.2 24 DC 3RA2415-8XH31-1BB4 3RA2415-8XH31-2BB4
16 4.7 7.5 9.2 24 DC 3RA2416-8XH31-1BB4 3RA2416-8XH31-2BB4
25 5.5 11 11 24 DC 3RA2417-8XH31-1BB4 3RA2417-8XH31-2BB4

Representation of the complete contactor assemblies for


star-delta (wye-delta) starting with optionally mountable
accessories, see page 3/160.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/167
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW IE3 ready IE4 ready IE3/IE4 ready

Fully wired and tested contactor assemblies for star-delta (wye-delta) starting · Size S0-S0-S0 · Up to 22 kW
AC operation or DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RA242.-8XF32-1A.2 3RA242.-8XE32-1BB4 3RA242.-8XF32-2A.2


Rated data AC-3 Rated control Screw terminals Spring-loaded
Operational Ratings of three-phase motors supply terminals
current Ie at 50 Hz and 60 Hz voltage Us
Article No. Price Article No. Price
up to at per PU per PU
400 V 230 V 400 V 690 V
A kW kW kW V
AC operation, 50/60 Hz
25 7.1 11 19 24 AC 3RA2423-8XF32-1AC2 3RA2423-8XF32-2AC2
110 AC 3RA2423-8XF32-1AG2 3RA2423-8XF32-2AG2
230 AC 3RA2423-8XF32-1AL2 3RA2423-8XF32-2AL2
32/40 11.4 15/18.5 19 24 AC 3RA2425-8XF32-1AC2 3RA2425-8XF32-2AC2
110 AC 3RA2425-8XF32-1AG2 3RA2425-8XF32-2AG2
230 AC 3RA2425-8XF32-1AL2 3RA2425-8XF32-2AL2
50 -- 22 19 24 AC 3RA2426-8XF32-1AC2 3RA2426-8XF32-2AC2
110 AC 3RA2426-8XF32-1AG2 3RA2426-8XF32-2AG2
230 AC 3RA2426-8XF32-1AL2 3RA2426-8XF32-2AL2
DC operation
25 7.1 11 19 24 DC 3RA2423-8XF32-1BB4 3RA2423-8XF32-2BB4
32/40 11.4 15/18.5 19 24 DC 3RA2425-8XF32-1BB4 3RA2425-8XF32-2BB4
50 -- 22 19 24 DC 3RA2426-8XF32-1BB4 3RA2426-8XF32-2BB4
For IO-Link connection
25 7.1 11 19 24 DC 3RA2423-8XE32-1BB4 3RA2423-8XE32-2BB4
32/40 11.4 15/18.5 19 24 DC 3RA2425-8XE32-1BB4 3RA2425-8XE32-2BB4
50 -- 22 19 24 DC 3RA2426-8XE32-1BB4 3RA2426-8XE32-2BB4
For AS-Interface integration
25 7.1 11 19 24 DC 3RA2423-8XH32-1BB4 3RA2423-8XH32-2BB4
32/40 11.4 15/18.5 19 24 DC 3RA2425-8XH32-1BB4 3RA2425-8XH32-2BB4
50 -- 22 19 24 DC 3RA2426-8XH32-1BB4 3RA2426-8XH32-2BB4

Representation of the complete contactor assemblies for


star-delta (wye-delta) starting with optionally mountable
accessories, see page 3/161.

* You can order this quantity or a multiple thereof.


3/168 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
IE3 ready IE4 ready IE3/IE4 ready SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW
Fully wired and tested contactor assemblies for star-delta (wye-delta) starting · Size S2-S2-S0 · Up to 45 kW and S2-S2-S2 · 55 kW
AC operation or AC/DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

3
3RA2437-8XF32-1A.2 3RA2434-8XE32-1NB3
Rated data AC-3 Rated control Screw terminals Spring-loaded
Operational Ratings of three-phase motors supply terminals
current Ie at 50 Hz and 60 Hz voltage Us Article No. Price Article No. Price
up to at per PU per PU
400 V 230 V 400 V 690 V
A kW kW kW V
AC operation, 50/60 Hz
50/65 19.6 22/30 34 24 AC 3RA2434-8XF32-1AC2 --
110 AC 3RA2434-8XF32-1AG2 --
230 AC 3RA2434-8XF32-1AL2 --
80 25 37 63 24 AC 3RA2435-8XF32-1AC2 --
110 AC 3RA2435-8XF32-1AG2 --
230 AC 3RA2435-8XF32-1AL2 --
86 27 45 63 24 AC 3RA2436-8XF32-1AC2 --
110 AC 3RA2436-8XF32-1AG2 --
230 AC 3RA2436-8XF32-1AL2 --
115 37 55 93 24 AC 3RA2437-8XF32-1AC2 --
110 AC 3RA2437-8XF32-1AG2 --
230 AC 3RA2437-8XF32-1AL2 --
AC/DC operation, 50/60 Hz AC or DC
With integrated coil circuit
(varistor integrated in electronics at the factory)
50/65 19.6 22/30 34 20 ... 33 AC/DC 3RA2434-8XF32-1NB3 --
80 25 37 63 20 ... 33 AC/DC 3RA2435-8XF32-1NB3 --
86 27 45 63 20 ... 33 AC/DC 3RA2436-8XF32-1NB3 --
115 37 55 93 20 ... 33 AC/DC 3RA2437-8XF32-1NB3 --
For IO-Link connection
50/65 19.6 22/30 34 20 ... 33 AC/DC 3RA2434-8XE32-1NB3 --
80 25 37 63 20 ... 33 AC/DC 3RA2435-8XE32-1NB3 --
86 27 45 63 20 ... 33 AC/DC 3RA2436-8XE32-1NB3 --
115 37 55 93 20 ... 33 AC/DC 3RA2437-8XE32-1NB3 --
For AS-Interface integration
50/65 19.6 22/30 34 20 ... 33 AC/DC 3RA2434-8XH32-1NB3 --
80 25 37 63 20 ... 33 AC/DC 3RA2435-8XH32-1NB3 --
86 27 45 63 20 ... 33 AC/DC 3RA2436-8XH32-1NB3 --
115 37 55 93 20 ... 33 AC/DC 3RA2437-8XH32-1NB3 --

Representation of the complete contactor assemblies for


star-delta (wye-delta) starting in size S2-S2-S2 with optionally
mountable accessories, see page 3/162.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 3/169
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
SIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW IE3 ready IE4 ready IE3/IE4 ready

Fully wired and tested contactor assemblies for star-delta (wye-delta) starting · Size S3-S3-S2 · Up to 90 kW
AC operation or AC/DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
3

3RA244.-8XF32-1A.2 3RA244.-8XE32-1NB3 3RA244.-8XH32-1NB3


Rated data AC-3 Rated control supply Screw terminals Spring-loaded
Operational Ratings of three-phase motors voltage Us terminals
current Ie at 50 Hz and 60 Hz Article No. Price Article No. Price
up to at per PU per PU
400 V 230 V 400 V 690 V
A kW kW kW V
AC operation, 50/60 Hz
115 30 55 90 24 AC 3RA2444-8XF32-1AC2 --
110 AC 3RA2444-8XF32-1AG2 --
230 AC 3RA2444-8XF32-1AL2 --
150 37 75 110 24 AC 3RA2445-8XF32-1AC2 --
110 AC 3RA2445-8XF32-1AG2 --
230 AC 3RA2445-8XF32-1AL2 --
160 45 90 132 24 AC 3RA2446-8XF32-1AC2 --
110 AC 3RA2446-8XF32-1AG2 --
230 AC 3RA2446-8XF32-1AL2 --
AC/DC operation, 50/60 Hz AC or DC
With integrated coil circuit
(varistor integrated in electronics at the factory)
115 30 55 90 20 ... 33 AC/DC 3RA2444-8XF32-1NB3 --
150 37 75 110 20 ... 33 AC/DC 3RA2445-8XF32-1NB3 --
160 45 90 132 20 ... 33 AC/DC 3RA2446-8XF32-1NB3 --
For IO-Link connection
115 30 55 90 20 ... 33 AC/DC 3RA2444-8XE32-1NB3 --
150 37 75 110 20 ... 33 AC/DC 3RA2445-8XE32-1NB3 --
160 45 90 132 20 ... 33 AC/DC 3RA2446-8XE32-1NB3 --
For AS-Interface integration
115 30 55 90 20 ... 33 AC/DC 3RA2444-8XH32-1NB3 --
150 37 75 110 20 ... 33 AC/DC 3RA2445-8XH32-1NB3 --
160 45 90 132 20 ... 33 AC/DC 3RA2446-8XH32-1NB3 --

Representation of the complete contactor assemblies for


star-delta (wye-delta) starting with optionally mountable
accessories, see page 3/163.

* You can order this quantity or a multiple thereof.


3/170 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
Contactor assemblies for star-delta (wye-delta) starting consisting of SIRIUS 3RT and 3TF6 contactors, up to 710 kW

■ Overview
The individual parts for the contactor assemblies for star-delta
(wye-delta) starting for customer assembly must be ordered
separately.
• 3RT contactors (see page 3/64 onwards) and
3RT12 and 3TF6 vacuum contactors (see page 3/135
onwards): Video: SIRIUS contactor assembly for star-delta (wye-delta) starting –
The operating times of the individual contactors are rated in configuration example with 75 kW contactors

3
such a way that no overlapping of the contact connection and
the arcing time between two contactors can occur on More information
reversing, provided they are interlocked by way of their
Homepage, see www.siemens.com/sirius
auxiliary switches (NC contact interlock) and the mechanical
interlock. Industry Mall, see www.siemens.com/product?3RA24_3RT
For assemblies with AC operation and 50/60 Hz, a dead Guide of use for contactors in safety applications, see
interval of 50 ms must be provided when used with voltages https://support.industry.siemens.com/cs/ww/en/view/109807687
over 500 V; a dead interval of 30 ms is recommended for use
with voltages up to and including 400 V. These dead times do
not apply to assemblies with DC operation.
The operating times of the individual contactors are not
affected by the mechanical interlock.
• Mechanical interlocks
- 3RT contactors and 3RT12 vacuum contactors: Adapter and
mechanical interlock to interlock S6 and S3, see page 3/108.
- 3TF68 vacuum contactors: Locking device for mechanical
interlock, see page 3/135.
• Wiring kits consisting of wiring modules or link rails and star
jumpers
- 3RT contactors and 3RT12 vacuum contactors:
see page 3/106 onwards
- 3TF68 vacuum contactors: see page 3/135
• Base plates
- 3RT contactors and 3RT12 vacuum contactors:
see page 3/113
- 3TF68 vacuum contactors: see page 3/135
Additional components
• For momentary-contact operation: auxiliary switch
(NO contact) for self-locking
• 3RB2 overload relays (see page 7/114 onwards),
SIMOCODE pro 3UF7 motor management and control
devices (see page 10/12 onwards) or 3RN2 thermistor motor
protection relays (see page 10/136 onwards) can be used for
overload protection.
The overload relay can either be mounted on the line
contactor or separately fitted. It must be set to 0.58 times
the rated motor current.
• Optional surge suppression for the S3 contactors; the
contactors in sizes S6 to S12 are wired as standard with
varistors.
The contactor assemblies for star-delta (wye-delta) starting
for customer assembly are designed for standard applications.
Note:
Contactor assemblies for star-delta (wye-delta) starting in
special applications such as very heavy starting1) or star-delta
(wye-delta) starting of special motors must be customized.
Help with designing such special applications is available from
our Technical Support,
www.siemens.com/support-request.

1)
For effective assistance from Technical Support, you must provide the
following details:
- Rated motor voltage,
- Rated motor current,
- Service factor, operating values
- Motor starting current factor
- Starting time
- Ambient temperature

Siemens IC 10 · 2023 3/171


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
Contactor assemblies for star-delta (wye-delta) starting consisting of SIRIUS 3RT and 3TF6 contactors, up to 710 kW
Contactor assemblies for star-delta (wye-delta) starting for customer assembly · Size S6-S6-S3 · Up to 160 kW

10
3

11

11

1
2
5

3 9

IC01_00630b
6

11
8
11
9

4 Additional connecting
cables are not shown.

Mountable accessories (optional) Contactor assemblies for star-delta (wye-delta) starting for customer assembly
To be ordered separately Type Page Individual parts Type Page
Q11 Q13 Q12
11 Box terminal blocks 3RT1955-4G 3/110 1 2 3 Contactors, 110 kW 3RT1054 3RT1054 3RT2045 3/51, 3/59,
3/63 ... 3/66
1 2 3 Contactors, 132 kW 3RT1055 3RT1055 3RT2046 3/51, 3/59,
3/63 ... 3/66
1 2 3 Contactors, 160 kW 3RT1056 3RT1056 3RT2047 3/51, 3/59,
3/63 ... 3/66
4 Assembly kit S6-S6-S3 3RA1953-3G 3/106
for contactors with box terminals
consisting of:
Wiring modules, bottom
5 Star jumper S3 3RT1946-4BA31 3/107
6 Adapter for the mechanical interlock 3RA1954-2G1) 3/108
between S6 and S3 (including two
connectors)
7 Mechanical interlock between S6 3RA1954-2A 3/108
and S3
8 Timing relay with star-delta 3RP257. 10/34
(wye-delta) function
9 Push-in lugs for star-delta 3ZY1311-0AA00 10/35
(wye-delta) timing relays
10 Base plate star-delta (wye-delta) 3RA1952-2E 3/113
11 Box terminal block 3RT1955-4G 3/110
1)
The 3RA1954-2G adapter cannot be used in conjunction
with 3RT204..-.KB coupling contactors, size S3.

3/172 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
Contactor assemblies for star-delta (wye-delta) starting consisting of SIRIUS 3RT and 3TF6 contactors, up to 710 kW
Contactor assemblies for star-delta (wye-delta) starting for customer assembly · Size S6-S6-S6 · Up to 160 kW

11

5 5

3
12
12

12

1
2

8 3 10

IC01_00629b
8

10
6

12
12

12

Mountable accessories (optional) Contactor assemblies for star-delta (wye-delta) starting for customer assembly
To be ordered separately Type Page Individual parts Type Page
Q11 Q13 Q12
12 Box terminal blocks 3RT1955-4G 3/110 1 2 3 Contactors, 110 kW 3RT1054 3RT1054 3RT1054 3/64 ... 3/66
1 2 3 Contactors, 132 kW 3RT1055 3RT1055 3RT1055 3/64 ... 3/66
1 2 3 Contactors, 160 kW 3RT1056 3RT1056 3RT1056 3/64 ... 3/66
4 5 Assembly kit S6-S6-S6 3RA1953-2B 3/106
for contactors with box terminals
consisting of:
4 Link rails, bottom
5 Star jumper S6
5 6 Assembly kit S6-S6-S6 3RA1953-2N 3/106
for contactors without box terminals
consisting of:
6 Link rails, bottom
5 Star jumper S6
7 Mechanical interlock 3RA1954-2A 3/108
8 Four connectors 3RA1932-2D 3/108
9 Timing relay with star-delta (wye-delta) function 3RP257. 10/34
10 Push-in lugs for star-delta (wye-delta) timing relays 3ZY1311-0AA00 10/35
11 Base plate star-delta (wye-delta) 3RA1952-2F 3/113
12 Box terminal block 3RT1955-4G 3/110

Video: SIRIUS contactor assembly for star-delta (wye-delta) starting – configuration example with 75 kW contactors

Siemens IC 10 · 2023 3/173


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
Contactor assemblies for star-delta (wye-delta) starting consisting of SIRIUS 3RT and 3TF6 contactors, up to 710 kW
Contactor assemblies for star-delta (wye-delta) starting for customer assembly · Size S10-S10-S6 · Up to 250 kW

9
3

10

10

2
5
8

3
6 7

IC01_00589b
10

10
8

Mountable accessories (optional) Contactor assemblies for star-delta (wye-delta) starting for customer assembly
To be ordered separately Type Page Individual parts Type Page
Q11 Q13 Q12
10 Box terminal blocks 3RT1966-4G 3/110 1 2 3 Contactors, 200 kW 3RT1.64 3RT1.64 3RT1054 3/64 ... 3/66, 3/130
1 2 3 Contactors, 250 kW 3RT1.65 3RT1.65 3RT1055 3/64 ... 3/66, 3/130
4 Assembly kit S10-S10-S6 3RA1963-3E 3/106
for contactors with box terminals
consisting of:
Wiring modules, bottom
5 Star jumper S6 3RT1956-4BA31 3/107
6 Mechanical interlock between 3RA1954-2A 3/108
S10 and S6
7 Timing relay with star-delta 3RP257. 10/34
(wye-delta) function
8 Push-in lugs for star-delta 3ZY1311-0AA00 10/35
(wye-delta) timing relays
9 Base plate star-delta (wye-delta) 3RA1962-2E 3/113
10 Box terminal block 3RT1966-4G 3/110

Video: SIRIUS contactor assembly for star-delta (wye-delta) starting – configuration example with 75 kW contactors

3/174 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
Contactor assemblies for star-delta (wye-delta) starting consisting of SIRIUS 3RT and 3TF6 contactors, up to 710 kW
Contactor assemblies for star-delta (wye-delta) starting for customer assembly · Size S10-S10-S10 · Up to 250 kW

3
5

10
10

10

3 8

IC01_00588b
10 7

8
4

Mountable accessories (optional) Contactor assemblies for star-delta (wye-delta) starting for customer assembly
To be ordered separately Type Page Individual parts Type Page
Q11 Q13 Q12
10 Box terminal blocks 3RT1966-4G 3/110 1 2 3 Contactors, 200 kW 3RT1.64 3RT1.64 3RT1.64 3/64 ... 3/66, 3/130
1 2 3 Contactors, 250 kW 3RT1.65 3RT1.65 3RT1.65 3/64 ... 3/66, 3/130
4 5 Assembly kit S10-S10-S10 3RA1963-2B 3/106
for contactors without box terminals
consisting of:
4 Link rails, bottom
5 Star jumper S10
6 Mechanical interlock 3RA1954-2A 3/108
7 Timing relay with star-delta 3RP257. 10/34
(wye-delta) function
8 Push-in lugs for star-delta 3ZY1311-0AA00 10/35
(wye-delta) timing relays
9 Base plate star-delta (wye-delta) 3RA1962-2F 3/113

Video: SIRIUS contactor assembly for star-delta (wye-delta) starting – configuration example with 75 kW contactors

Siemens IC 10 · 2023 3/175


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
Contactor assemblies for star-delta (wye-delta) starting consisting of SIRIUS 3RT and 3TF6 contactors, up to 710 kW
Contactor assemblies for star-delta (wye-delta) starting for customer assembly · Size S12-S12-S10 · Up to 500 kW

9
3

10
10

10
1
2

3 8

IC01_00587b
10
10

10 8

Mountable accessories (optional) Contactor assemblies for star-delta (wye-delta) starting for customer assembly
To be ordered separately Type Page Individual parts Type Page
Q11 Q13 Q12
10 Box terminal blocks 3RT1966-4G 3/110 1 2 3 Contactors, 355 kW 3RT1.75 3RT1.75 3RT1.64 3/64 ... 3/66, 3/130
1 2 3 Contactors, 400 kW 3RT1.75 3RT1.75 3RT1.65 3/64 ... 3/66, 3/130
1 2 3 Contactors, 500 kW 3RT1.76 3RT1.76 3RT1.66 3/64 ... 3/66, 3/130
4 Assembly kit S12-S12-S10 3RA1973-3E 3/106
for contactors with box terminals
consisting of:
Wiring modules, bottom
5 Star jumper S10 3RT1966-4BA31 3/107
6 Mechanical interlock between S12 and S10 3RA1954-2A 3/108
7 Timing relay with star-delta (wye-delta) function 3RP257. 10/34
8 Push-in lugs for star-delta 3ZY1311-0AA00 10/35
(wye-delta) timing relays
9 Base plate star-delta (wye-delta) 3RA1972-2E 3/113
10 Box terminal blocks 3RT1966-4G 3/110

Video: SIRIUS contactor assembly for star-delta (wye-delta) starting – configuration example with 75 kW contactors

3/176 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
Contactor assemblies for star-delta (wye-delta) starting consisting of SIRIUS 3RT and 3TF6 contactors, up to 710 kW
Contactor assemblies for star-delta (wye-delta) starting for customer assembly · Size S12-S12-S12 · Up to 500 kW

3
5

10

10

10

3 8

IC01_00586b
10 7

Mountable accessories (optional) Contactor assemblies for star-delta (wye-delta) starting for customer assembly
To be ordered separately Type Page Individual parts Type Page
Q11 Q13 Q12
10 Box terminal blocks 3RT1966-4G 3/110 1 2 3 Contactors, 400 kW 3RT1.75 3RT1.75 3RT1.75 3/64 ... 3/66, 3/130
1 2 3 Contactors, 500 kW 3RT1.76 3RT1.76 3RT1.76 3/64 ... 3/66, 3/130
4 5 Assembly kit S12-S12-S12 3RA1973-2B 3/106
for contactors without box
terminals
consisting of:
4 Link rails, bottom
5 Star jumper S12
6 Mechanical interlock 3RA1954-2A 3/108
7 Timing relay with star-delta 3RP257. 10/34
(wye-delta) function
8 Push-in lugs for star-delta 3ZY1311-0AA00 10/35
(wye-delta) timing relays
9 Base plate star-delta (wye-delta) 3RA1972-2F 3/113

Video: SIRIUS contactor assembly for star-delta (wye-delta) starting – configuration example with 75 kW contactors

Siemens IC 10 · 2023 3/177


© Siemens 2023

Switching devices – Contactors and contactor assemblies – for switching motors


Contactor assemblies for star-delta (wye-delta) starting
Contactor assemblies for star-delta (wye-delta) starting consisting of SIRIUS 3RT and 3TF6 contactors, up to 710 kW
Contactor assemblies for star-delta (wye-delta) starting for customer assembly · Sizes 14-14-S12 · Up to 710 kW

7
3

1
4

2 6

IC01_00778
6

Contactor assemblies for star-delta (wye-delta) starting for customer assembly


Individual parts Type Page
Q11 Q13 Q12
1 2 Contactors, 710 kW 3TF68 3TF68 3RT127. 3/130 ... 3/132
3 4 Assembly kit 14-14-S12 3TX7680-1B 3/135
for contactors without box terminals
consisting of:
3 Wiring modules on the top and bottom
4 Star jumper S12
5 Timing relay with star-delta (wye-delta) function 3RP257. 10/34
6 Push-in lugs for star-delta (wye-delta) timing relays 3ZY1311-0AA00 10/35
7 Base plate star-delta (wye-delta) 3TX7681-1B 3/135

3/178 Siemens IC 10 · 2023


4
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications

Price groups
PG 41A, 41B

4/2 Introduction

Contactors for special


applications
4/7 SIRIUS 3RT.4 contactors for low or
non-inductive loads (AC-1), 3-pole
up to 2 650 A
4/21 SIRIUS 3RT.3 contactors, 4-pole,
up to 525 A

4
4/36 SIRIUS 3RT25 contactors, 4-pole,
2 NO + 2 NC
4/42 SIRIUS 3RT26 contactors for capacitive
loads (AC-6b), 3-pole
4/52 SIRIUS 3RT23 to 3RT26, 3RT14
contactors
Contactors for railway applications
4/54 - SIRIUS 3RT contactors with extended
operating range, 3-pole
4/63 - SIRIUS 3RH2 contactor relays with
extended operating range
4/66 - 3TH4 contactor relays, 8-pole
4/68 - 3TC contactors for switching DC
voltage, 2-pole
4/70 3TC contactors for switching DC
voltage, 1- and 2-pole

3/138 3TG10 power relays/miniature


contactors

Siemens IC 10 · 2023
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications

Introduction

■ Overview
AC-3/AC-3e

AC-3e

le
po
3-
3RT12 3TF6
500 A/250 kW 820 A/450 kW
4

AC-3/AC-3e

AC-3e

le
po
3-
3RT20 3RT10
110 A/55 kW 500 A/250 kW
AC-1

le
po
3-
3RT24 3RT14
160 A 690 A 2 650 A
AC-1

le
po
4-
3RT23 3RT13
160 A 525 A
AC- 6b

le
po
3-

3RT26
151 A/100 kvar
AC-3

IC01_00563b
le
po
4-

3RT25
80 A/37 kW

Overview of the 3RT and 3TF contactors

4/2 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications

Introduction

More information
Homepage, see www.siemens.com/sirius Conversion tool, see www.siemens.com/conversion-tool
Industry Mall, see www.siemens.com/product?3RT_3TK_3TC TIA Selection Tool Cloud (TST Cloud), see
www.siemens.com/tstcloud/?node=Contactor

4
Size S3 S6 S10 S12
Type 3RT244. 3RT1456 3RT146. 3RT1476
3-pole 3RT244 and 3RT145 to 3RT147 contactors
Type 3RT2446 3RT2448 3RT1456 3RT1466 3RT1467 3RT1476
Number of main contacts 3 NO 3 NO 3 NO 3 NO
AC, AC/DC operation (p. 4/16) (p. 4/17, 4/18) (p. 4/17, 4/18) (p. 4/17, 4/18)
AC-1
Ui V 1 000
Ue V 690
Ie up to 690 V 40 °C A 140 160 275 400 500 690
60 °C A 130 140 250 380 450 Standard operating
mechanism: 650,
solid-state operating
mechanism: 600

Accessories for contactors


Auxiliary switches 3RH29, 3RA28 (p. 3/87 ... 3/95) 3RH19, 3RT1926 (p. 3/90, 3/92, 3/94, 3/96)
Function modules 3RA281. (p. 3/100) --
(direct-on-line starting, star-delta
(wye-delta) starting)
Terminal covers 3RT2946-4EA4 (p. 3/112) 3RT1956-4EA. (p. 3/112)
Box terminal blocks -- 3RT1955/56-4G (p. 3/110)
Surge suppressors 3RT2936, 3RT2946 (p. 3/97, 3/98) 3RT1956-1C (RC element) (p. 3/98)

Type 3RT1481, 3RT1482 3RT1483 3RT1485, 3RT1486 3RT1487


3-pole 3RT148 contactors
Type 3RT1481 3RT1482 3RT1483 3RT1485 3RT1486 3RT1487
Number of main contacts 3 NO
AC/DC operation (p. 4/19)
AC-1
Ui V 1 000
Ue V 1 000
Ie 40 °C A 900 1 050 1 260 1 700 2 100 2 650

Accessories for contactors


Second auxiliary switch, lateral 3RH1981-1JA11 (p. 4/19)
Spare parts for contactors
First auxiliary switch, lateral 3RH1981-1DA11 (p. 4/20)
Phase barriers 3RT1983-4AA1 (p. 4/20) 3RT1987-4AA1 (p. 4/20)
Withdrawable coils 3RT1982-5A.31 (p. 4/20) 3RT1983-5AP31 (p. 4/20) 3RT1987-5AP31 (p. 4/20)

Siemens IC 10 · 2023 4/3


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications

Introduction

Size S00 S0 S2 S3
Type 3RT231. 3RT232. 3RT233. 3RT234.
4-pole 3RT23 contactors
Type 3RT2316 3RT2317 3RT2325 3RT2326 3RT2327 3RT2336 3RT2337 3RT2344 3RT2346 3RT2348
4

Number of main contacts 4 NO 4 NO 4 NO 4 NO


AC, DC and AC/DC operation (p. 4/29, 4/31) (p. 4/29 ... 4/31) (p. 4/29 ... 4/33) (p. 4/29 ... 4/33)
AC-1
Ui V 690
Ue V 690
Ie up to 690 V 40 °C A 18 22 35 40 50 60 110 110 140 160
60 °C A 16 20 30 35 42 55 95 100 130 140
AC-3
Ie up to 400 V A 9 12 15.5 15.5 15.5 -- -- -- -- --
P at 400 V kW 4 5.5 7.5 7.5 7.5 -- -- -- -- --

Accessories for contactors


Auxiliary switches 3RH29, 3RA28 (p. 3/87 ... 3/95)
Function modules 3RA281. (p. 3/100)
(direct-on-line starting, star-delta
(wye-delta) starting)
Terminal covers -- 3RT2936-4EA4 (p. 3/112) 3RT2946-4EA4 (p. 3/112)
Surge suppressors 3RT2916 (p. 3/97, 3/98) 3RT2936 (p. 3/97, 3/98) 3RT2936, 3RT2946 (p. 3/97, 3/98)

Size S6 S10 S12


Type 3RT1355 3RT136. 3RT137.
4-pole 3RT13 contactors
Type 3RT1355 3RT1363 3RT1364 3RT1373 3RT1374 3RT1375
Number of main contacts 4 NO 4 NO 4 NO
AC/DC operation (p. 4/34) (p. 4/34) (p. 4/34)
AC-1
Ui V 1 000
Ue V 690 1 000
Ie 40 °C A 200 275 350 400 500 525

Accessories for contactors


Second auxiliary switch, lateral 3RH1951-1SA11 (p. 4/35)
Terminal covers 3RT1956-4EB10 (p. 4/35) 3RT1966-4EB10 (p. 4/35) 3RT1976-4EB10 (p. 4/35)
Mechanical interlocks 3RA1954-3A (p. 4/35)
Bus connectors offset -- 3RT1966-4D (p. 4/35) 3RT1976-4D (p. 4/35)
Spare parts for contactors
First auxiliary switch, lateral 3RH1951-1TA11 (p. 4/35)

4/4 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications

Introduction

Size S00 S0 S2 S3
Type 3RT251. 3RT252. 3RT253. 3RT254.
4-pole 3RT25 contactors
Type 3RT2516 3RT2517 3RT2518 3RT2526 3RT2535 3RT2536 3RT2544 3RT2545

4
Number of main contacts 2 NO + 2 NC 2 NO + 2 NC 2 NO + 2 NC 2 NO + 2 NC
AC, DC and AC/DC operation (p. 4/39, 4/40) (p. 4/39, 4/40) (p. 4/39, 4/41) (p. 4/39, 4/41)
AC-1
Ui V 690
Ue V 690
Ie up to 690 V 40 °C A 18 22 22 40 60 70 100 125
60 °C A 16 20 20 35 55 60 90 105
AC-3
Ie up to 400 V NO A 9 12 16 25 35 41 65 80
NC A 9 9 9 25 (20)1) 35 41 65 80
P
At 400 V NO kW 4 5.5 7.5 11 18.5 22 30 37
NC kW 4 4 4 11 (7.5)1) 18.5 22 30 37
At 230 V NO kW 2.2 3/2.2 4/2.2 5.5 11 11 18.5 22
NC kW 2.2 3/2.2 4/2.2 5.5 11 11 18.5 22

Accessories for contactors


Auxiliary switches 3RH29, 3RA28 (p. 3/87 ... 3/95)
Function modules (direct-on-line starting, 3RA281. (p. 3/100)
star-delta (wye-delta) starting)
Terminal covers -- 3RT2936-4EA4 3RT2946-4EA4
(p. 3/112) (p. 3/112)
Surge suppressors 3RT2916 3RT2926 3RT2936 3RT2936, 3RT2946
(p. 3/97, 3/98) (p. 3/97, 3/98) (p. 3/97, 3/98) (p. 3/97, 3/98)
1) The value in brackets applies to the NC for DC operation.

Further contactors
• SIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole,
see page 4/42 onwards
• 3TC contactors for switching DC voltage, 1-pole and 2-pole,
see page 4/70 onwards
• Contactors for railway applications
- SIRIUS 3RT contactors with extended operating range, 3-pole,
see page 4/54 onwards
- SIRIUS 3RH2 contactor relays with extended operating
range, see page 4/65
- 3TH4 contactor relays, 8-pole, see page 4/66 onwards

Siemens IC 10 · 2023 4/5


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications

Introduction
Connection methods Voltage data
The following connection options are available for The data for 3-phase power systems according to
3RT contactors depending on the size and version: IEC 60947-4-1 are valid for the following forms of power supply:
.

• 3RT2 contactors Voltage data Line system configurations


- Sizes S00 and S0: screw terminals or spring-loaded Ue Three-phase Three-phase
terminals both for the main as well as for the auxiliary and four-wire systems three-wire systems
control circuits
- Sizes S2 and S3: screw terminals (complete devices)
or spring-loaded terminals (auxiliary circuit only)

IC01_00703
• 3RT13 contactors, sizes S6 to S12: Busbar connections

IC01_00709
(partly with bus connectors offset), auxiliary and control
circuits with screw terminals
4

• 3RT14 contactors: Busbar connections


V V V
Screw terminals 230 -- 230
400 230/400 400
440 260/440 440
Spring-loaded terminals
500 -- 500
690 400/690 690 (only from size S3)
Busbar connections 1 000 -- 1 000
-- Not specified
The connection method is indicated in the
corresponding tables by the symbols shown on
orange backgrounds.

4/6 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A

■ Overview

4
3-pole AC-1 contactors
top row: 3RT148 contactors
bottom row: 3RT244, 3RT145 to 3RT147 contactors
Standards If there are further switching elements in the circuit, such as the
auxiliary contact system of an overload relay that operates the
IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1 (auxiliary switches) contactor, the short-circuit protection necessary for this must
Contactors with increased tamper protection also be considered.
Increased tamper protection is ensured either by using our For further recommendations, e.g. the use of miniature circuit
contactor versions with factory-installed, permanently mounted breakers or circuit breakers for equipment in control circuits, see
auxiliary switches which are protected against mechanical Control panel tip – Selecting and dimensioning suitable power
external actuation (e.g. 3RT14..-.....-3PA0 contactors), or by supplies quickly and reliably.
using the 3RT1926-4MA10 sealable cover as an accessory, Short-circuit and overload protection of contactors with
(see page 3/112). a digital input
Protecting connections against short circuit, overload and A typical rated current of 20 mA applies to these inputs
overvoltage according to the PLC input types according to IEC 60947-4-1.
All connections must generally be protected against overload The inputs can be protected accordingly.
and short circuits using suitable measures. Different constraints • Contactors with PLC and F-PLC inputs:
must be considered depending on the type of connection: - For 3RT14..-.S and 3RT14..-.N, marked with +/-
Short-circuit and overload protection of main connections • Supply voltage connections A1 - A2:
- For 3RT14..-.N, protection based on the load characteristics
For information on the protection of a free-standing contactor, must be employed.
see the technical product data sheet. For information on power consumption, see the technical
For more information on complete units such as contactors with product data sheet.
overload relays or contactors with motor starter protectors as the - For 3RT14..-.S, protection is already integrated.
motor feeder, see Configuration Manual for load feeders. Short-circuit and overload protection of other connections
Short-circuit and overload protection of auxiliary connections The 3RT14..-.P contactor version with remaining lifetime
For information on the protection of auxiliary contacts, see the indicator (RLT) also has additional connections H1 - H2 and
technical product data sheet R1 - R2.

Short-circuit and overload protection of control supply voltage If A1 - A2 is already protected, further protection of H1 - H2 is not
connections or supply voltage connections required.

First of all, the relevant standards and regulations for configuring For protection specifications for protecting R1 - R2, see the
control panels and the parts and components installed in them technical product data sheet.
must be taken into account, for example for cable dimensioning.
One possible protection for these circuits could be the selection
of a suitable power supply, i.e. one with a current-limiting
function. In the selection of the source and the connecting cable,
the load characteristics of the contactor must be considered
(short-time inrush current peaks for solid-state operating
mechanisms, switch-on power, holding power).

Siemens IC 10 · 2023 4/7


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A
Protection against overvoltage at the control supply voltage 3RT145 to 3RT147 contactors
connection
The contactors are powered via a supply voltage with an
3RT244 contactors supplied without a coil circuit can be operating range from 0.8 to 1.1 x Us, optionally also controlled
retrofitted with RC elements, varistors, diodes or diode depending on the chosen mode of operation. Alternatively,
assemblies (combination of diode and Zener diode for short control is via the separate 24 V DC control signal input. Various
break times) for damping switching overvoltages in the coil and rated voltage ranges for AC/DC control are available.
can be ordered separately as accessories, see page 3/97
onwards. The following control and/or operating mechanism versions are
available:
3RT14 contactors are already equipped with coil damping • 3RT14..-.A contactors:
(varistor). Standard operating mechanism for AC and DC operation
Note: (power consumption reduced from closing to closed)
The break times of the contactor, the opening delay times of the • Solid-state operating mechanisms:
Overvoltage damping of the operating mechanism coil is
4

NO contacts and the closing delay times of the NC contacts


increase with damping. already integrated in the electronics for contactors with
solid-state operating mechanisms.
For more information about influencing the time response using The following versions are available:
damping, see Equipment Manual. - 3RT14..-.N contactors:
With two operating modes: direct control or via PLC input
Connection methods (24 V DC)
Main circuit - 3RT14..-.P contactors:
Control via PLC input (24 V DC) only, but with additional
• 3RT244 contactors: remaining lifetime indicator (RLT)
Screw terminals with box terminal; - 3RT14..-.S contactors:
direct connection to the connecting bar possible with cable Control via fail-safe PLC input (24 V DC) only, for simplification
lugs when the box terminal is removed. of safety applications
• 3RT145 to 3RT147 contactors:
Screw terminals with connecting bars that the cables can be 3RT148 contactors
connected to using either cable lugs or flexible or rigid The contactors are equipped with a solid-state operating
busbars. Alternatively, box terminals are available as mechanism for AC/DC control; coil damping is integrated.
accessories. The operating range is 0.85 to 1.1 x Us.
• 3RT148 contactors:
Screw terminals with connecting bars Replacing solenoid coils, operating mechanisms or spare
contacts
Auxiliary and control circuits
3RT244 contactors
• 3RT24, 3RT145 to 3RT147:
Screw or spring-loaded terminals Solenoid coil or spare contact replacement is possible.
• 3RT148: 3RT145 to 3RT147 contactors
Screw terminals
The operating mechanisms for 3RT14..-.A/-.N/-.P contactors are
Electromagnetic compatibility (EMC) removable and can be replaced simply by unlocking and pulling
them out. The spare contacts can also be replaced.
The contactors comply with the conditions for environment A
according to IEC 60947-1. NOTICE:
Removal or changing of the operating mechanism is not
Note: permitted for 3RT14..-.S contactors with fail-safe control.
When the contactors are used in an environment with frequency 3RT148 contactors
converters, the configuration notes must be observed, see
Equipment Manual. The operating mechanisms are removable and can be replaced
simply by unlocking and pulling them out.
Contact reliability of the auxiliary contacts
Fitting auxiliary contacts and mounting additional auxiliary
If voltages  110 V and currents  100 mA are to be switched, switches
the auxiliary contacts of the 3RT contactors or 3RH contactor
relays should be used as they guarantee a high level of contact Features in delivery condition
reliability. • 3RT244 contactors:
These auxiliary contacts are particularly suitable for solid-state Two auxiliary contacts (1 NO + 1 NC) are integrated in the
circuits with currents  1 mA at a voltage  17 V. basic unit.
• 3RT14 contactors:
Operating mechanism types These contactors are supplied with two laterally mounted
3RT244 contactors auxiliary switches with two contacts each (2 NO + 2 NC).
The contactors are available as versions with conventional AC or Expansion possibilities
DC operating mechanisms or as versions with a wide-range All basic units can be expanded using auxiliary switches;
solid-state operating mechanism and a universal actuating the permissible configuration must be observed.
voltage (AC or DC operation).
For detailed information about the fitting of auxiliary switches for
With an operating range from 0.8 to 1.1 x Us, control takes place 3RT244 contactors, see pages 3/81 to 3/86.
via the control supply voltage connection A1 - A2.
Accessories and spare parts
• 3RT244 and 3RT145 to 3RT147 contactors, see Basic units,
page 3/69 onwards
• 3RT148 contactors, see page 4/19 onwards

4/8 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A
Connection of contactors to fail-safe control modules
While contactors with smaller power ratings can be connected Due to their fail-safe control input, the special versions from size
directly to the outputs of fail-safe controllers, implementing S6 to S12 (3RT14..-.S) provide a much simpler way of doing this.
safety-related applications with standard contactors with higher
power is much more complicated and elaborate because of the More information, see
necessary coupling links. • Safety technology, page 11/1 onwards
• Guide of use for contactors in safety applications
Example for SIL 2 and SIL 3/PL e application – previously:

3RT1 contactor in size S6 with standard or


L/+
solid-state operating mechanism with PLC-IN
• Safety-related tripping only possible via
3RT2 contactor or coupling links and F-DQ

4
3RH2 contactor relay
• Standard operating mechanism:
operational switching via coupling links and
3RT2 contactor F-DQ
• Solid-state operating mechanism:
Feedback operational switching with PLC-IN and DQ
EMERGENCY SIMATIC S7-1500 DQ 3RT1
STOP F-DQ
contactor
A1
PLC-IN
A2

3RT1 contactor

A1
PLC-IN
A2
IC01_00540

N/-

Application with safety-related disconnection with standard contactors using the example of a 3RT145 contactor

Example for SIL 3/PL e (left-hand side) or SIL 2/PL c (right-hand side) application – new:

L/+ 3RT1 contactor in size S6 with solid-state


operating mechanism with fail-safe control input
F-PLC-IN (e.g. 3RT1456-6SP36)
• Safety-related tripping and operational switching
Feedback via F-PLC-IN and F-DQ
• SIL 2/PL c possible with only one contactor

SIL 3/PL e with


two contactors

EMERGENCY SIMATIC S7-1500


STOP 3RT1 contactor
F-DQ
A1
F-PLC-IN SIL 2/PL c with
one contactor L/+
A2
Feedback

3RT1 contactor 3RT1 contactor


A1 A1
F-PLC-IN F-PLC-IN
A2 A2
IC01_00542

N/- N/-

Application with safety-related disconnection with contactors with fail-safe control using the example of a 3RT145 contactor

Siemens IC 10 · 2023 4/9


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A
Overview graphics with mountable accessories
• 3RT244 contactors, see page 3/11
• 3RT145 to 3RT147 contactors, see page 3/12 onwards
• 3RT148 contactors, see following graphic

1 3RT1481 to 3RT1487 contactors


1 (3RT1487 contactor is shown)

2 Can be mounted onto side of contactor


2 3RH1981-1JA11 second auxiliary switch
2
4

IC01_00694

3RT1481 to 3RT1487 contactors with mountable accessories

■ Application
The 3RT.4 contactors can be used for the following applications:
• For switching weak or non-inductive loads (AC-1)
• Disconnecting loads or power generation plants from the grid
(e.g. wind turbines or photovoltaic systems)
• Disconnecting frequency converters from the grid

4/10 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/24229/td https://support.industry.siemens.com/cs/ww/en/ps/24229/man
For FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/24229/faq Guide of use for contactors in safety applications, see
https://support.industry.siemens.com/cs/ww/en/view/109807687

Type 3RT2446, 3RT2448 3RT1456 3RT1466 3RT1467 3RT1476


Size S3 S6 S10 S12
General data
Dimensions (W x H x D)

4
• Basic units
- Screw/spring-loaded terminals mm 70 x 140 x 152 120 x 172 x 170 145 x 210 x 202 160 x 214 x 225
H

• Basic unit with mounted auxiliary


D

switch W
- Screw terminals mm 70 x 140 x 196 120 x 172 x 217 145 x 210 x 251 160 x 214 x 271
- Spring-loaded terminals mm 70 x 140 x 200 --
• Basic unit with mounted function
module or solid-state time-delayed
auxiliary switch
- Screw/spring-loaded terminals mm 70 x 140 x 226 --
Permissible mounting position

NSB0_00649a
NSB0_00478c
360° 22,5° 22,5° 22,5° 22,5°
The contactors are designed for operation on a vertical 90° 90°
mounting surface.

Upright mounting position --

NSB0_00477a

Special version required


Mechanical endurance
• Basic units and Oper- 10 million
basic units with mounted auxiliary switch ating
cycles
• Basic units with solid-state compatible auxiliary switch Oper- 5 million --
ating
cycles
Electrical endurance Oper- 0.5 million 0.35 0.5 million
for utilization category AC-1, at Ue = 400 V ating million
cycles
Rated insulation voltage Ui V 1 000
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 6 8
Protective separation between the coil and the main V 690
contacts according to IEC 60947-1, Annex N
Mirror contacts according to IEC 60947-4-1, Annex F
A mirror contact is an auxiliary NC contact that cannot be
closed simultaneously with an NO main contact.
• Integrated auxiliary switches Yes --
• Removable auxiliary switches -- Yes
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -55 ... +80
Short-circuit protection
Main circuit
• Version of the fuse link required for short-circuit protection
of the main circuit
- For type of coordination 1 gG: 250 A gG: 355 A gG: 500 A gG: 800 A
(690 V, 100 kA) (690 V, 100 kA) (690 V, 100 kA) (690 V, 50 kA)
- For type of coordination 2 gG: 250 A gG: 350 A gG: 500 A gG: 710 A
(690 V, 100 kA) (690 V, 100 kA) (690 V, 100 kA) (690 V, 100 kA)
Auxiliary circuit
• Version of the fuse link required for short-circuit protection A Fuse gG: 10
of the auxiliary switch
• Version of the miniature circuit breaker required for A On request
short-circuit protection of the auxiliary switch
Short-circuit protection for contactors with overload relays See Configuration Manual for load feeders
Short-circuit protection for fuseless load feeders See
• 3RA2 load feeders, page 8/5 onwards
• Configuration Manual for load feeders

Siemens IC 10 · 2023 4/11


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A

Type 3RT2446, 3RT2448 3RT1456 3RT1466, 3RT1467 3RT1476


-.A -.N -.A -.N/-.P/-.S -.A -.N/-.P/-.S -.A -.N/-.P/-.S
Size S3 S6 S10 S12
Control
Solenoid coil operating range (AC/DC) 0.8 ... 0.8 x Us min ... 1.1 x Us max
1.1 x Us
Power consumption of the solenoid coils
(for cold coil and 1.0 x Us)
• AC operation, 50 Hz, Closing VA 296 --
standard version P.f.  0.61 --
Closed VA 19 --
P.f.  0.38 --
• AC operation, 50/60 Hz, Closing VA 348/296 --
standard version P.f.  0.62/0.55 --
4

Closed VA 25/18 --
P.f.  0.35/0.41 --
• AC operation, 50/60 Hz, Closing VA 326/326 --
for USA/Canada P.f.  0.62/0.55 --
Closed VA 22/22 --
P.f.  0.38/0.4 --
• AC/DC operation Closing for VA -- 163 300 280 590 530 830 750
AC operation
P.f.  -- 0.9 0.8 0.9 0.8 0.9 0.8
Closed for VA -- 3.1 5.8 4.8 6.7 8.5 9.2 9
AC operation
P.f.  -- 0.8 0.6 0.9 0.4 0.9 0.4
Closing for W -- 76 360 320 650 580 920 800
DC operation
Closed for W -- 1.8 5.2 2.8 7.4 3.4 10 3.6
DC operation
Type of PLC control input according to IEC 60947-1
• Solid-state operating mechanism 3RT14..-.N/-.P -- Type 2
3RT14..-.S -- Type 1
• Rated voltage V DC -- 24
• Operating range V DC -- 17 ... 30
• Power consumption mA --  30
• Recovery time after mains failure, typical s -- 2
(applicable only for fail-safe version 3RT14..-.S)

Type 3RT2446 3RT2448 3RT1456 3RT1466 3RT1467 3RT1476


Size S3 S6 S10 S12
Rated data of the main contacts
Load rating with AC
Utilization category AC-1
• Rated operational currents Ie At 40 °C up to 690 V A 140 160 275 400 500 690
At 60 °C up to 690 V A 130 140 250 380 450 Standard operating
mechanism: 650,
solid-state operating
mechanism: 600
At 40 °C up to 1 000 V A 60 80 --
At 60 °C up to 1 000 V A 60 80 --
• Minimum cross-section in the main mm2 50 70 140 240 300 480
circuit at maximum AC-1 rated value
Power loss per main conducting path At Ie/AC-1/40 °C W 9.8 12.8 28.8 35.2 35.2 61.9

Type 3RT2446, 3RT2448


Size S3
Conductor cross-sections
Main conductors (1 or 2 conductors can be connected) Screw terminals

• Solid mm2 2 x (2.5 ... 16)1)


• Stranded mm2 2 x (6 ... 16)1); 2 x (10 ... 50)1); 1 x (10 ... 70)1)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (2.5 ...35)1); 1 x (2.5 ... 50)1)
• AWG cables, solid or stranded AWG 2 x (10 ... 1/0)1); 1 x (10 ... 2/0)1)
• Terminal screws Hexagon socket, size 4
- Tightening torque Nm 4.5 ... 6 (40 ... 53 lb.in)
Auxiliary conductors and control conductors
(1 or 2 conductors can be connected)
• Solid or stranded mm2 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1)
• AWG cables, solid or stranded AWG 2 x (20 ... 16)1); 2 x (18 ... 14)1)
• Terminal screws M3 (for Pozidriv size 2;  5 ... 6 mm)
- Tightening torque Nm 0.8 ... 1.2 (7 ... 10.3 lb.in)
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in one of the ranges specified.

4/12 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A

Type 3RT1456 3RT1466, 3RT1476


3RT1467
Size S6 S10 S12
Conductor cross-sections
Main conductors Screw terminals
(1 or 2 conductors can be connected)
With mounted box terminals Type 3RT1955-4G 3RT1956-4G 3RT1966-4G
Terminal screws M10 (hexagon socket, A/F 4) M10 (hexagon socket, A/F 4) M12 (hexagon socket, A/F 5)
• Tightening torque Nm 10 ... 12 10 ... 12 20 ... 22
lb.in 90 ... 110 90 ... 110 180 ... 195
Front clamping point connected
• Finely stranded with end sleeve (DIN 46228) mm2 16 ... 70 16 ... 120 70 ... 240
mm2
NSB0_00479

• Finely stranded without end sleeve 16 ... 70 16 ... 120 70 ... 240

4
• Stranded mm2 16 ... 70 16 ... 120 95 ... 300
• AWG cables, solid or stranded AWG 6 ... 2/0 6 ... 250 kcmil 3/0 ... 600 kcmil
• Ribbon cable conductors mm Min. 3 x 9 x 0.8, Min. 3 x 9 x 0.8, Min. 6 x 9 x 0.8,
(Number x Width x Thickness) max. 6 x 15.5 x 0.8 max. 10 x 15.5 x 0.8 max. 20 x 24 x 0.5
Rear clamping point connected
• Finely stranded with end sleeve (DIN 46228) mm2 16 ... 70 16 ... 120 120 ... 185
NSB0_00480

• Finely stranded without end sleeve mm2 16 ... 70 16 ... 120 120 ... 185
• Stranded mm2 16 ... 70 16 ... 120 120 ... 240
• AWG cables, solid or stranded AWG 6 ... 2/0 6 ... 250 kcmil 250 ... 500 kcmil
• Ribbon cable conductors mm Min. 3 x 9 x 0.8, Min. 3 x 9 x 0.8, Min. 6 x 9 x 0.8,
(Number x Width x Thickness) max. 6 x 15.5 x 0.8 max. 10 x 15.5 x 0.8 max. 20 x 24 x 0.5
Both clamping points connected
(minimum cross-section 16 mm²)
• Finely stranded with end sleeve (DIN 46228) mm2 Max. 1 x 50, 1 x 70 Max. 1 x 95, 1 x 120 Min. 2 x 50, max. 2 x 185
• Finely stranded without end sleeve mm2 Max. 1 x 50, 1 x 70 Max. 1 x 95, 1 x 120 Min. 2 x 50, max. 2 x 185
NSB0_00481

• Stranded mm2 Max. 1 x 50, 1 x 70 Max. 1 x 95, 1 x 120 Min. 2 x 70, max. 2 x 240
• AWG cables, solid or stranded AWG Max. 2 x 1/0 Max. 2 x 3/0 Min. 2 x 2/0,
max. 2 x 500 kcmil
• Ribbon cable conductors mm Max. 2 x (6 x 15.5 x 0.8) Max. 2 x (10 x 15.5 x 0.8) Max. 2 x (20 x 24 x 0.5)
(Number x Width x Thickness)
Busbar connections
• Connecting bar (max. width) mm 17 25
- Bore diameter mm 9 11
1) 2)
Cable lug connection
• Finely stranded with cable lug mm2 16 ... 95 50 ... 240
• Stranded with cable lug mm2 25 ... 120 70 ... 240
• AWG cables, solid or stranded AWG 4 ... 250 kcmil 2/0 ... 500 kcmil
• Terminal screws M8 x 25 (A/F 13) M10 x 30 (A/F 17)
- Tightening torque Nm 10 ... 14 14 ... 24
lb.in 90 ... 124 124 ... 210
Auxiliary conductors
(1 or 2 conductors can be connected)
• Solid mm2 2 x (0.5 ... 1.5)3), 2 x (0.75 ... 2.5)3) according to IEC 60947;
max. 2 x (0.75 ... 4)3)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)3); 2 x (0.75 ... 2.5)3)
• AWG cables, solid or stranded AWG 2 x (18 ... 14)
• Terminal screws M3 (Pozidriv size 2)
- Tightening torque Nm 0.8 ... 1.2
lb.in 7 ... 10.3
Auxiliary conductors4) Spring-loaded terminals
(1 or 2 conductors can be connected)
• Operating devices 3.0 x 0.5; 3.5 x 0.5
• Solid mm2 2 x (0.25 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.25 ... 2.5)
• AWG cables, solid or stranded AWG 2 x (24 ... 14)
1) 3RT1456: When connecting cable lugs according to DIN 46235, use the 3) If two different conductor cross-sections are connected to one clamping
3RT1956-4EA1 terminal cover for conductor cross-sections from 95 mm2 point, both cross-sections must lie in one of the ranges specified.
to maintain the phase clearance, see page 3/112. 4)
Max. external diameter of the conductor insulation: 3.6 mm.
2)
3RT1466, 3RT1467 and 3RT1476: When connecting cable lugs according On spring-loaded terminals with conductor cross-sections  1 mm2
to DIN 46234 for conductor cross-sections larger than 240 mm2 and an insulation stop is recommended, see page 3/115.
according to DIN 46235 for conductor cross-sections larger than 185 mm2,
the 3RT1966-4EA1 terminal cover is required to maintain the phase
clearance, see page 3/112.

Siemens IC 10 · 2023 4/13


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A

Type 3RT1481- 3RT1482- 3RT1483- 3RT1485- 3RT1486- 3RT1487-


6A.36 6A.36 6AP36 6AP36 6AP36 6AP36
General data
Dimensions
• Width mm 285 431
• Height mm 352 403
H
• Depth mm 250 246

D
W

Mounting position For vertical mounting surface can be rotated  30°,


for vertical mounting surface can be tilted  30° forward or backward
Installation altitude at height above sea level, maximum m 2 000
Insulation voltage at pollution degree 3
• Of the main circuit V 1 000
4

• Of the auxiliary circuit V 600


Impulse withstand voltage
• Of the main circuit kV 8
• Of the auxiliary circuit kV 6
Product function, mirror contact according to Yes
IEC 60947-4-1
Ambient temperature
• During operation °C -25 ... +55
• During storage °C -40 ... +80
Short-circuit protection
Version of the fuse link required
• For short-circuit protection of the main circuit for type of aR: 1 000 A aR: 1 100 A aR: 1 400 A aR: 2 200 A aR: 2 500 A aR: 2 800 A
coordination 2 (1 000 V, (1 000 V, (1 000 V, (1 000 V, (1 000 V, (1 000 V,
30 kA) 42 kA) 42 kA) 42 kA) 42 kA) 50 kA)
• For short-circuit protection of the auxiliary switch gG: 16 A (600 V, 1 kA)

4/14 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A

Type 3RT1481- 3RT1482- 3RT1483- 3RT1485- 3RT1486- 3RT1487-


6AF36 6AP36 6AF36 6AP36 6AP36 6AP36 6AP36 6AP36
Control circuit/control
Operating range factor of the control supply voltage,
rated value of the solenoid coil
• At AC at 50 Hz 0.85 ... 1.1
• At AC at 60 Hz 0.85 ... 1.1
• At DC 0.85 ... 1.1
Solenoid coil closing power for DC W 1 400 2 000 1 400 2 000 2 700 2 800
Closing apparent power of the solenoid coil for AC
• At 50 Hz VA 1 000 1 700 1 800
• At 60 Hz VA 1 000 1 700 1 800
Solenoid coil closed for DC W 6 7 6 7 8 11

4
Closed apparent power of the solenoid coil for AC
• At 50 Hz VA 18 23 18 23 20 33
• At 60 Hz VA 18 23 18 23 20 33
Main circuit
Operational current at AC-1
• Up to 690 V
- At an ambient temperature of 40 °C A 900 1 050 1 260 1 700 2 100 2 650
- At an ambient temperature of 55 °C A 900 1 050 1 260 1 700 2 100 2 650
• Up to 1000 V
- At an ambient temperature of 40 °C A 900 1 050 1 260 1 700 2 100 2 650
- At an ambient temperature of 55 °C A 900 1 050 1 260 1 700 2 100 2 650
Type of electrical connection for the main circuit Busbar connections
Minimum cross-section in the main circuit for mm2 600 800 1 000 1 500 2 000 3 000
max. AC-1 rated value

Type 3RT1481-6A.36, 3RT1483-6AP36 3RT1485-6AP36, 3RT1487-6AP36


3RT1482-6A.36 3RT1486-6AP36
Conductor cross-sections
Control circuit/control
Type of connectable conductor cross-sections for
auxiliary contacts
• Solid 2x (1 ... 2.5 mm2)
• Solid or stranded 2x (1 ... 2.5 mm2)
• Finely stranded with end sleeve 2x (1 ... 2.5 mm2)
Main circuit
Width of connecting bar mm 40 50 103
Thickness of connecting bar mm 10 13 10 20
Diameter of hole mm 17 13 15 13

Siemens IC 10 · 2023 4/15


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A

■ Selection and ordering data


Size S3: AC operation or AC/DC operation
• Coil circuits (varistors, diodes, etc.) retrofittable
• Auxiliary switches can be retrofitted
• Main and control conductors: Screw terminals
4

3RT244.-1...0
Size Rated data Auxiliary contacts Rated control supply voltage Us Screw terminals PU PS* PG
AC-1, tu: (UNIT,
SET, M)
40 °C 60 °C
Operational Ident. No. Version 50 Hz AC 50 Hz AC or DC
current Ie Article No. Price
up to per PU

690 V 690 V
A A NO NC V V
For screw fixing and snap-on mounting on TH 35-15 and TH 75-15 DIN rails
AC operation
S3 140 130 11 1 1 24 -- 3RT2446-1AB00 1 1 unit 41B
110 -- 3RT2446-1AF00 1 1 unit 41B
230 -- 3RT2446-1AP00 1 1 unit 41B
160 140 11 1 1 24 -- 3RT2448-1AB00 1 1 unit 41B
110 -- 3RT2448-1AF00 1 1 unit 41B
230 -- 3RT2448-1AP00 1 1 unit 41B
AC/DC operation
With integrated coil circuit (varistor integrated in electronics at the factory)
S3 140 130 11 1 1 -- 20 ... 33 3RT2446-1NB30 1 1 unit 41B
-- 83 ... 155 3RT2446-1NF30 1 1 unit 41B
-- 175 ... 280 3RT2446-1NP30 1 1 unit 41B
160 140 11 1 1 -- 20 ... 33 3RT2448-1NB30 1 1 unit 41B
-- 83 ... 155 3RT2448-1NF30 1 1 unit 41B
-- 175 ... 280 3RT2448-1NP30 1 1 unit 41B

Other voltages according to page 4/52 on request.


Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


4/16 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A
Sizes S6 to S12: AC/DC operation
• 3RT14..-.A standard operating mechanism • Auxiliary and control conductors: Screw terminals
• Solid-state operating mechanism • Main conductors: Busbar connections;
- 3RT14..-.N with 24 V DC control signal input a connection kit with screws, spring washers and nuts is
- 3RT14..-.P with 24 V DC control signal input and remaining enclosed.
lifetime indicator (RLT)
• For screw fixing

4
3RT1456-6A.36 3RT1466-6A.36 3RT1476-6A.36 3RT1476-6N.36 3RT1476-6P.35

Size Rated data Auxiliary Rated control Screw terminals PU PS* PG


contacts, lateral supply voltage Us (UNIT,
AC-1, tu: SET, M)
40 °C 60 °C
Operational current Ie Version 50/60 Hz AC or DC
up to Article No. Price
per PU
690 V 690 V
A A NO NC V
Standard operating mechanism for AC and DC operation
(power consumption reduced from closing to closed)
With integrated coil circuit (varistor integrated at the factory)
S6 275 250 2 2 110 ... 127 3RT1456-6AF36 1 1 unit 41B
220 ... 240 3RT1456-6AP36 1 1 unit 41B
S10 400 380 2 2 110 ... 127 3RT1466-6AF36 1 1 unit 41B
220 ... 240 3RT1466-6AP36 1 1 unit 41B
500 450 2 2 110 ... 127 3RT1467-6AF36 1 1 unit 41B
220 ... 240 3RT1467-6AP36 1 1 unit 41B
S12 690 650 2 2 110 ... 127 3RT1476-6AF36 1 1 unit 41B
220 ... 240 3RT1476-6AP36 1 1 unit 41B
Solid-state operating mechanism
With 24 V DC control signal input
e.g. for control by PLC
With integrated coil circuit (varistor integrated in electronics at the factory)
S6 275 250 2 2 96 ... 127 3RT1456-6NF36 1 1 unit 41B
200 ... 277 3RT1456-6NP36 1 1 unit 41B
S10 400 380 2 2 96 ... 127 3RT1466-6NF36 1 1 unit 41B
200 ... 277 3RT1466-6NP36 1 1 unit 41B
500 450 2 2 96 ... 127 3RT1467-6NF36 1 1 unit 41B
200 ... 277 3RT1467-6NP36 1 1 unit 41B
S12 690 650 2 2 96 ... 127 3RT1476-6NF36 1 1 unit 41B
200 ... 277 3RT1476-6NP36 1 1 unit 41B
With 24 V DC control signal input · with remaining lifetime indicator (RLT)
e.g. for control by PLC
With integrated coil circuit (varistor integrated in electronics at the factory)
S6 275 250 1 1 96 ... 127 3RT1456-6PF35 1 1 unit 41B
200 ... 277 3RT1456-6PP35 1 1 unit 41B
S10 400 380 1 1 96 ... 127 3RT1466-6PF35 1 1 unit 41B
200 ... 277 3RT1466-6PP35 1 1 unit 41B
500 450 1 1 96 ... 127 3RT1467-6PF35 1 1 unit 41B
200 ... 277 3RT1467-6PP35 1 1 unit 41B
S12 690 650 1 1 96 ... 127 3RT1476-6PF35 1 1 unit 41B
200 ... 277 3RT1476-6PP35 1 1 unit 41B

Other voltages according to page 4/53 on request.


Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/17
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A
Sizes S6 to S12: AC/DC operation
• Certified and fail-safe 24 V DC control input with max. 20 mA, • Version with removable lateral auxiliary switches or
e.g. for control via the fail-safe output module of a controller permanently mounted auxiliary switches
(F-PLC) or safety relay • For screw fixing
• Achievable Safety Integrity Level (SIL) according to IEC 62061 • Auxiliary and control conductors: Screw terminals
and Performance Level (PL) according to ISO 13849-1 with • Main conductors: Busbar connections;
corresponding fault diagnostics: a connection kit with screws, spring washers and nuts is
- With one contactor: SIL 2/PL c enclosed.
- With two contactors in series: SIL 3/PL e
- Fail-safe applications can be implemented using this More information, see
contactor. • Safety technology, page 11/1 onwards
• Guide of use for contactors in safety applications
4

3RT1456-6S.36 3RT1466-6S.36 3RT1476-6S.36 3RT1456-6S.36-3PA0 3RT1476-6S.36-3PA0


Size Rated data according to Auxiliary Rated control supply Screw terminals PU PS* PG
IEC 60947-4-1 contacts, lateral voltage Us (UNIT,
AC-1, tu: SET, M)
40 °C 60 °C
Operational current Ie Version 50/60 Hz AC or DC
up to Article No. Price
per PU
690 V 690 V
A A NO NC V
Solid-state operating mechanism
With two removable laterally mounted auxiliary switches
With integrated coil circuit (varistor integrated in electronics at the factory)
S6 275 250 2 2 96 ... 127 3RT1456-6SF36 1 1 unit 41B
200 ... 277 3RT1456-6SP36 1 1 unit 41B
S10 400 380 2 2 96 ... 127 3RT1466-6SF36 1 1 unit 41B
200 ... 277 3RT1466-6SP36 1 1 unit 41B
500 450 2 2 96 ... 127 3RT1467-6SF36 1 1 unit 41B
200 ... 277 3RT1467-6SP36 1 1 unit 41B
S12 690 650 2 2 96 ... 127 3RT1476-6SF36 1 1 unit 41B
200 ... 277 3RT1476-6SP36 1 1 unit 41B
With two permanently laterally mounted auxiliary switches
With integrated coil circuit (varistor integrated in electronics at the factory)
S6 275 250 2 2 96 ... 127 3RT1456-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1456-6SP36-3PA0 1 1 unit 41B
S10 400 380 2 2 96 ... 127 3RT1466-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1466-6SP36-3PA0 1 1 unit 41B
500 450 2 2 96 ... 127 3RT1467-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1467-6SP36-3PA0 1 1 unit 41B
S12 690 650 2 2 96 ... 127 3RT1476-6SF36-3PA0 1 1 unit 41B
200 ... 277 3RT1476-6SP36-3PA0 1 1 unit 41B
Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


4/18 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A
AC/DC operation
• Solid-state operating mechanism • For screw fixing
• Version with two laterally mounted auxiliary switches • Auxiliary and control conductors: Screw terminals
(2 NO + 2 NC each) • Main conductors: Busbar connections

4
3RT1481-6A.36, 3RT1482-6A.36 3RT1483-6AP36 3RT1485-6AP36, 3RT1486-6AP36 3RT1487-6AP36
Rated data according to Auxiliary Rated control supply voltage Us Busbar PU PS* PG
IEC 60947-4-1 contacts, lateral connections (UNIT,
AC-1, tu: 40 °C Version 50/60 Hz AC DC SET, M)
Operational current Ie Article No. Price
up to per PU
1 000 V
A NO NC V V
Solid-state operating mechanism
With integrated coil circuit
900 2 2 100 ... 127 100 ... 110 3RT1481-6AF36 1 1 unit 41B
200 ... 240 200 ... 220 3RT1481-6AP36 1 1 unit 41B
1 050 2 2 100 ... 127 100 ... 110 3RT1482-6AF36 1 1 unit 41B
200 ... 240 200 ... 220 3RT1482-6AP36 1 1 unit 41B
1 260 2 2 100 ... 240 100 ... 220 3RT1483-6AP36 1 1 unit 41B
1 700 2 2 100 ... 240 100 ... 220 3RT1485-6AP36 1 1 unit 41B
2 100 2 2 100 ... 240 100 ... 220 3RT1486-6AP36 1 1 unit 41B
2 650 2 2 100 ... 240 100 ... 220 3RT1487-6AP36 1 1 unit 41B
Accessories, see next table; spare parts, see page 4/19.

■ Accessories
Overview graphics for 3RT148 contactors with mountable
accessories, see page 4/10. More information
Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/24229/man

For contactors Auxiliary contacts Screw terminals PU PS* PG


Version (UNIT,
SET, M)
Article No. Price
per PU

Type NO NC Left Right


Second auxiliary switch (1 NO + 1 NC)
Lateral mounting on the right and/or the left
3RT148. 1 1 61 53 71 83 3RH1981-1JA11 1 1 unit 41B

62 54 72 84

3RH1981-1JA11

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/19
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A

■ Spare parts
For Auxiliary contacts Rated control supply Article No. Price PU PS* PG
contactors voltage Us per PU (UNIT,
Version 50/60 Hz AC DC SET, M)

Type NO NC Left Right V V


First auxiliary switch (1 NO + 1 NC)
Lateral mounting on the right and/or Screw terminals
the left
3RT148. 1 1 21 13 31 43 -- -- 3RH1981-1DA11 1 1 unit 41B
4

22 14 32 44

3RH1981-1DA11
Phase barriers
(1 set = 4 units)
3RT1481 -- -- -- -- -- -- 3RT1983-4AA1 1 1 unit 41B
...
3RT1483

3RT1983-4AA1
3RT1485 -- -- -- -- -- -- 3RT1987-4AA1 1 1 unit 41B
...
3RT1487

3RT1987-4AA1
Withdrawable coils ·AC/DC operation
3RT1481, -- -- -- -- 100 ... 127 100 ... 110 3RT1982-5AF31 1 1 unit 41B
3RT1482 -- -- -- -- 200 ... 240 200 ... 220 3RT1982-5AP31 1 1 unit 41B
3RT1483 -- -- -- -- 100 ... 240 100 ... 220 3RT1983-5AP31 1 1 unit 41B

3RT1982-5A.31,
3RT1983-5AP31
3RT1485 -- -- -- -- 100 ... 240 100 ... 220 3RT1987-5AP31 1 1 unit 41B
...
3RT1487

3RT1987-5AP31

* You can order this quantity or a multiple thereof.


4/20 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A

■ Overview
Protection against overvoltage at the control supply voltage
connection
3RT23 contactors supplied without a coil circuit can be
retrofitted with RC elements, varistors, diodes or diode
assemblies (combination of diode and Zener diode for short
break times) for damping switching overvoltages in the coil and
can be ordered separately as accessories, see page 3/97
onwards.
3RT13 contactors are already equipped with coil damping
(varistor).
Note:

4
The break times of the contactor, the opening delay times of the
NO contacts and the closing delay times of the NC contacts
increase with damping.
For more information about influencing the time response using
damping, see Equipment Manual.
3RT231 to 3RT234 and 3RT135 to 3RT137 contactors, Connection methods
with screw terminals
Main circuit
Standards • 3RT231 and 3RT232 contactors:
IEC 60947-1, IEC 60947-4-1, IEC60947-5-1 (auxiliary switches) Screw terminals or spring-loaded terminals;
spring-loaded terminals with convenient plug-in design for
Protecting connections against short circuit, overload and device connectors
overvoltage
• 3RT233 and 3RT234 contactors:
All connections must generally be protected against overload Screw terminals with box terminal;
and short circuits using suitable measures. Different constraints direct connection to the connecting bar possible with cable
must be considered depending on the type of connection: lugs for 3RT234 when the box terminal is removed.
Short-circuit and overload protection of main connections • 3RT135 to 3RT137 contactors:
Screw terminals with connecting bars that the cables can be
For information on the protection of a free-standing contactor, connected to using either cable lugs or flexible or rigid
see the technical product data sheet. busbars.
For more information on complete units such as contactors with • 3RT136 and 3RT137 contactors:
overload relays or contactors with motor starter protectors as the These can be fitted with bus connectors offset, see page 4/35.
motor feeder, see Configuration Manual for load feeders.
Auxiliary and control circuits
Short-circuit and overload protection of auxiliary connections
Screw terminals
For information on the protection of auxiliary contacts, see the
technical product data sheet. Electromagnetic compatibility

Short-circuit and overload protection of control supply voltage The contactors fulfill the requirements for environment category A.
connections or supply voltage connections Note:
First of all, the relevant standards and regulations for configuring When the contactors are used in an environment with frequency
control panels and the parts and components installed in them converters, the configuration notes must be observed, see
must be taken into account, for example for cable dimensioning. Equipment Manual.
One possible protection for these circuits could be the selection
of a suitable power supply, i.e. one with a current-limiting
function. In the selection of the source and the connecting cable,
the load characteristics of the contactor must be considered
(short-time inrush current peaks for solid-state operating
mechanisms, switch-on power, holding power).
If there are further switching elements in the circuit, such as the
auxiliary contact system of an overload relay that operates the
contactor, the short-circuit protection necessary for this must
also be considered.
For further recommendations, e.g. the use of miniature circuit
breakers or circuit breakers for equipment in control circuits, see
Control panel tip – Selecting and dimensioning suitable power
supplies quickly and reliably.

Siemens IC 10 · 2023 4/21


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A
Contact reliability of the auxiliary contacts Replacing solenoid coils, operating mechanisms or spare
contacts
If voltages  110 V and currents  100 mA are to be switched,
the auxiliary contacts of the 3RT contactors or 3RH contactor 3RT23 contactors
relays should be used as they guarantee a high level of contact
reliability. Solenoid coil replacement is possible. Only the contacts for
3RT233 contactors can be replaced.
These auxiliary contacts are particularly suitable for solid-state
circuits with currents  1 mA at a voltage  17 V. 3RT13 contactors
It is not possible to change the operating mechanism or contacts.
Motor protection
3RT23 contactors Fitting auxiliary contacts and mounting additional auxiliary
switches
For protection against overload, 3RU2 thermal overload relays
(see page 7/89 onwards) or 3RB3 electronic overload relays Features in the delivery state
(see page 7/102 onwards) can be mounted on the 3RT23 • 3RT23 contactors
4

contactors. - 3RT231 contactor:


An auxiliary contact is integrated in the basic unit.
3RT13 contactors - 3RT232 to 3RT234 contactors:
For protection against overload, 3RB2 electronic overload relays The basic units contain two integrated auxiliary contacts
(see page 7/114 onwards) can be mounted on the 3RT13 (1 NO + 1 NC).
contactors. • 3RT13 contactors
These contactors are supplied with two laterally mounted
Operating mechanism types auxiliary switches.
3RT23 contactors Expansion possibilities
The contactors are available as versions with conventional AC All basic units can be expanded using auxiliary switches;
or DC operating mechanisms or as versions with a wide-range the permissible configuration must be observed.
solid-state operating mechanism and a universal actuating
voltage (AC or DC operation possible). For detailed information about the fitting of auxiliary switches for
3RT23 contactors, see pages 3/81 to 3/86.
Control takes place via the control supply voltage connection
A1 - A2 with varying operating ranges (see relevant product data Accessories and spare parts
sheet for further details). • 3RT231 to 3RT234 contactors, see page 3/69 onwards
3RT13 contactors • 3RT135 to 3RT137 contactors, see page 4/35
The contactors are fitted with a wide-range solid-state operating
mechanism that can be controlled with both 50/60 Hz AC and DC.
The operating range of the DC control is 0.8 x Us min and
1.1 x Us max, and for AC operation 0.85 x Us min and 1.1 x Us max.

4/22 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A
Overview graphic with mountable accessories
• 3RT23 contactors, see page 3/8 onwards
• 3RT135 to 3RT137 contactors, see following graphic

4 5

4
1

1
2

IC01_00577a
5

4
5

1 4-pole 3RT13 contactors, sizes S6 to S12 4 3RT19.6-4D bus connectors offsets, can be mounted on the top or
(scope of supply: The contactors are supplied with two laterally bottom (providing no terminal cover 55 is mounted)
mounted auxiliary switch blocks)
5 3RT19.6-4EB10 terminal covers, can be mounted on the top or bottom
2 3RH1951-1SA11 second auxiliary switch block, can be laterally (providing no bus connectors offset 44 is mounted)
mounted on the left or right
3 3RA1954-3A mechanical interlock for configuring contactor
assemblies:
Two 3RT13 contactors of the same size (S6, S10 and S12) can be
interlocked with each other. The laterally mounted auxiliary switches
of the contactors must be removed beforehand.
The mechanical interlock cannot be used in conjunction with the bus Same accessories for sizes S6 to S12
connectors offset (4)
4 . Different accessories depending on size

Size S6 S10 S12


1 Contactor 3RT1355 3RT1363 3RT1364 3RT1373 3RT1374 3RT1375
( e = 200 A) ( e = 275 A) ( e = 350 A) ( e = 400 A) ( e = 500 A) ( e = 525 A)

2 Second auxiliary 3RH1951-1SA11


switch block
3 Mechanical interlock 3RA1954-3A

4 Bus connectors offset -- 3RT1966-4D 3RT1976-4D


(from > 275 A) (from > 450 A)

5 Terminal cover 3RT1956-4EB10 3RT1966-4EB10 3RT1976-4EB10

3RT135 to 3RT137 contactors with mountable accessories

Siemens IC 10 · 2023 4/23


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A

■ Application
The 3RT.3 contactors can be used for the following applications: We additionally offer special versions of the 3RT23 contactors for
• 4-pole switching of weak or non-inductive loads (AC-1) switching motor-driven loads (AC-3).
• Disconnecting loads or power generation plants from the grid
• For system transfers

■ Technical specifications
More information
Technical specifications, see Manuals, see
4

https://support.industry.siemens.com/cs/ww/en/ps/16165/td https://support.industry.siemens.com/cs/ww/en/ps/16165/man
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16165/faq

Type 3RT2316, 3RT2317 3RT2325 to 3RT2327 3RT2336, 3RT2337 3RT2344, 3RT2346, 3RT2348
Size S00 S0 S2 S3
General data
Dimensions (W x H x D) (The values in brackets
AC or DC operation apply for DC
operation)
H

• Basic units
- Screw terminals mm 45 x 58 x 73 60 x 85 x 97 (107) 75 x 114 x 130 96 x 140 x 152
D

- Spring-loaded terminals W mm 45 x 70 x 73 61 x 102 x 97 (107) -- --


• Basic unit with mounted
auxiliary switch
- Screw terminals mm 45 x 58 x 117 60 x 85 x 141 (151) 75 x 114 x 174 96 x 140 x 196
- Spring-loaded terminals mm 45 x 70 x 121 61 x 102 x 145 (155) -- --
• Basic unit with mounted
function module or solid-state
time-delayed auxiliary switch
- Screw terminals mm 45 x 58 x 147 60 x 85 x 171 (181) 75 x 114 x 204 96 x 140 x 226
- Spring-loaded terminals mm 45 x 70 x 147 61 x 102 x 171 (181) -- --
Permissible mounting position
The contactors are designed for operation
NSB0_00478c

360° 22,5° 22,5°


on a vertical mounting surface.

Upright mounting position

NSB0_00477a
Special version required
Mechanical endurance Oper- 30 million 10 million
ating
cycles
Electrical endurance at Ie/AC-1 Oper- Approx. 0.5 million
ating
cycles
Rated insulation voltage Ui V 690
(pollution degree 3)
Protective separation V 400 690
between the coil and the main contacts
according to IEC 60947-1, Annex N
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -55 ... +80

4/24 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A

Type 3RT2316, 3RT2317 3RT2325, 3RT2326 3RT2326-1...0-4AA0 3RT2327


Size S00 S0
Short-circuit protection
Main circuit
• Version of the fuse link required for short-circuit
protection of the main circuit
- For type of coordination 1 gG: 35 A gG: 63 A gG: 100 A (690 V, 100 kA), gG: 63 A
(690 V, 100 kA) (690 V, 100 kA) aM: 50 A (690 V, 100 kA), (690 V, 100 kA)
BS88: 100 A (415 V, 80 kA)
- For type of coordination 2 gG: 20 A gG: 35 A (690 V, 100 kA), gG: 20 A
(690 V, 100 kA) aM: 20 A (690 V, 100 kA), (690 V, 100 kA)
BS88: 35 A (415 V, 80 kA)
Auxiliary circuit

4
• Version of the fuse link required for short-circuit Fuse gG: 10 A (690 V, 1 kA)
protection of the auxiliary switch
• Miniature circuit breaker version required for 6 A (230 V, 400 A, C characteristic)
short-circuit protection of the auxiliary switch

Type 3RT2336, 3RT2337 3RT2344, 3RT2346 3RT2346-1...0-4AA0 3RT2348


Size S2 S3
Short-circuit protection
Main circuit
• Version of the fuse link required for short-circuit
protection of the main circuit
- For type of coordination 1 gG: 160 A gG: 250 A gG: 250 A (690 V, 100 kA), gG: 250 A
(690 V, 100 kA) (690 V, 100 kA) aM: 160 A (690 V, 100 kA), (690 V, 100 kA)
BS88: 200 A (415 V, 80 kA)
- For type of coordination 2 gG: 63 A gR: 80 A gR: 250 A gG: 160 A (690 V, 100 kA), gR: 250 A
(690 V, (690 V, (690 V, 100 kA) aM: 100 A (690 V, 100 kA), (690 V, 100 kA)
100 kA) 100 kA) BS88: 125 A (415 V, 80 kA)
Auxiliary circuit
• Version of the fuse link required for short-circuit Fuse gG: 10 A (690 V, 1 kA)
protection of the auxiliary switch
• Miniature circuit breaker version required for 6 A (230 V, 400 A, C characteristic)
short-circuit protection of the auxiliary switch

Siemens IC 10 · 2023 4/25


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A

Type 3RT2316 3RT2317 3RT2325 3RT2326, 3RT2327 3RT2336, 3RT2337 3RT2344, 3RT2346, 3RT2348
Size S00 S0 S2 S3
Control
Solenoid coil operating range
• AC operation At 50 Hz 0.8 ... 1.1 x Us
At 60 Hz 0.85 ... 1.1 x Us 0.8 ... 1.1 x Us
• DC operation At 50 °C 0.8 ... 1.1 x Us --
At 60 °C 0.85 ... 1.1 x Us --
• AC/DC operation -- 0.8 ... 1.1 x Us
Power consumption of the solenoid coils
(for cold coil and 1.0 x Us)
• AC operation, 50 Hz, standard version
4

- Closing VA -- 77 190 296


- P.f.  -- 0.82 0.72 0.61
- Closed VA -- 9.8 16 19
- P.f.  -- 0.25 0.37 0.38
• AC operation, 50/60 Hz, standard version
- Closing VA 27/24.3 37/33 81/79 210/188 348/296
- P.f.  0.8/0.75 0.72/0.74 0.69/0.65 0.62/0.55
- Closed VA 4.2/3.3 5.7/4.4 10.5/8.5 17.2/16.5 25/18
- P.f.  0.25/0.25 0.25/0.28 0.36/0.39 0.35/0.41
• AC operation, 60 Hz, USA, Canada
- Closing VA 31.7 43 87 188 326
- P.f.  0.77 0.76 0.67 0.55
- Closed VA 4.8 6.5 9.4 16.5 22
- P.f.  0.25 0.28 0.37 0.4
• AC/DC operation
- Closing for AC operation VA -- 40 151
- P.f.  -- 0.95 0.95
- Closed for AC operation VA -- 2 3.5
- P.f.  -- 0.95 0.95
- Closing for DC operation W -- 23 76
- Closed for DC operation W -- 1 2.7
• DC operation W 4 5.9 -- --1)
(closing = closed)
1)
In the case of AC/DC coils, increased pickup currents (6.5 A on average)
arise during the first 200 ms.

Type 3RT2316 3RT2317 3RT2325 3RT2326 3RT2327 3RT2336 3RT2337 3RT2344 3RT2346 3RT2348
Size S00 S0 S2 S3
Rated data of the main contacts
Load rating with AC
Utilization category AC-1
• Rated operational At 40 °C, up to 690 V A 18 22 35 40 50 60 110 110 140 160
currents Ie (110)1)
At 60 °C, up to 690 V A 16 20 30 35 42 55 95 100 130 140
(100)1)
• Rated power for AC At 230 V kW 6 7.5 11 13 16 21 36 38 49 53
loads 400 V kW 10.5 13 20 23 28 36 63 72 92 105
P.f. = 0.95
(at 60 °C)
• Minimum cross- mm2 2.5 4 10 16 35 50 (35)1) 70
section in the main
circuit at maximum
AC-1 rated value
Power loss per main conducting path
• At Ie/AC-1 At 40 °C W 1.1 1.6 1.8 2.4 3 3.2 9.7 7.3 11.8 15.4
• At Ie/AC-3 At 400 V W -- -- -- (2.6)1) -- (4.3)1) -- -- (6.8)1) --
1) The values in brackets apply for 3RT23.6-1...0-4AA0 versions.

Data for North America


Technical specifications of 3RT contactors, see page 3/45
onwards.

4/26 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A

Type 3RT1355-6A.36 3RT1363-6A.36 3RT1364-6A.36 3RT1373-6A.36,


3RT1374-6A.36,
3RT1375-6A.36
Size S6 S10 S12
General data
Dimensions
• Width mm 120 140 184
• Height mm 150 196 225
H

• Depth mm 128 153 180


W D

Mounting position For vertical mounting surface can be rotated  180°,


and with 0° rotation can be tilted forward or backward  30°, or standing
Installation altitude at height above sea level, m 2 000

4
maximum
Insulation voltage at pollution degree 3
• Of the main circuit V 1 000
• Of the auxiliary circuit V 690
Impulse withstand voltage
• Of the main circuit kV 8
• Of the auxiliary circuit kV 6
Product function, mirror contact according to Yes
IEC 60947-4-1
Ambient temperature
• During operation °C -40 ... +60
• During storage °C -40 ... +70
Short-circuit protection
Version of the fuse link required
• For short-circuit protection of the main circuit for gG: 250 A gG: 355 A gG: 400 A gG: 630 A
type of coordination 2 (500 V, 100 kA) (500 V, 100 kA) (500 V, 100 kA) (500 V, 100 kA)
• For short-circuit protection of the auxiliary switch gG: 10 A (690 V, 1 kA)

Type 3RT1355- 3RT1363- 3RT1364-


6AE36 6AF36 6AP36 6AR36 6AE36 6AF36 6AP36 6AR36 6AE36 6AF36 6AP36 6AR36
Size S6 S10
Control circuit/control
Operating range factor of the control supply
voltage, rated value of the solenoid coil
• At AC at 50 Hz 0.85 ... 1.1
• At AC at 60 Hz 0.85 ... 1.1
• At DC 0.8 ... 1.1
Solenoid coil closing for DC W 210 130 135 205 130 190 205 130 190
Closing apparent power of the solenoid coil
for AC
• At 50 Hz VA 225 170 130 205 165 175 220 185 165 175 220 185
• At 60 Hz VA 225 170 130 205 165 175 220 185 165 175 220 185
Solenoid coil closed for DC W 2.5 3 4 2.5 4 2.5 4
Closed apparent power of the solenoid coil
for AC
• At 50 Hz VA 5.5 4 6 16 6 4 7 16 6 4 7 16
• At 60 Hz VA 5.5 4 6 16 6 4 7 16 6 4 7 16
Main circuit
Operational current at AC-1
• Up to 690 V
- At an ambient temperature of 40 °C A 200 275 350
- At an ambient temperature of 60 °C A 175 250 300
• Up to 1000 V
- At an ambient temperature of 40 °C A -- 250 275
- At an ambient temperature of 60 °C A -- 225 250

Siemens IC 10 · 2023 4/27


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A

Type 3RT1373- 3RT1374- 3RT1375-


6AE36 6AF36 6AP36 6AR36 6AE36 6AF36 6AP36 6AR36 6AE36 6AF36 6AP36 6AR36
Size S12
Control circuit/control
Operating range factor of the control supply
voltage, rated value of the solenoid coil
• At AC at 50 Hz 0.85 ... 1.1
• At AC at 60 Hz 0.85 ... 1.1
• At DC 0.8 ... 1.1
Solenoid coil closing for DC W 400 360 410 600 400 360 410 600 400 360 410 600
Closing apparent power of the solenoid coil
for AC
• At 50 Hz VA 475 340 385 420 475 340 385 420 475 340 385 420
4

• At 60 Hz VA 475 340 385 420 475 340 385 420 475 340 385 420
Solenoid coil closed for DC W 3.5 2.5 4.5 4.7 3.5 2.5 4.5 4.7 3.5 2.5 4.5 4.7
Closed apparent power of the solenoid coil
for AC
• At 50 Hz VA 8.5 17 17.5 21 8.5 17 17.5 21 8.5 17 17.5 21
• At 60 Hz VA 8.5 17 17.5 21 8.5 17 17.5 21 8.5 17 17.5 21
Main circuit
Operational current at AC-1
• Up to 690 V
- At an ambient temperature of 40 °C A 400 500 525
- At an ambient temperature of 60 °C A 350 400 425
• Up to 1000 V
- At an ambient temperature of 40 °C A 350 375 400
- At an ambient temperature of 60 °C A 300 325 350

Type 3RT1355- 3RT1363- 3RT1364- 3RT1373- 3RT1374- 3RT1375-


6A.36 6A.36 6A.36 6A.36 6A.36 6A.36
Size S6 S10 S12
Conductor cross-sections
Type of electrical connection for the main Connecting bar Connecting Connecting bar Connecting bar,
circuit bar, bus bus connectors offset
connectors > 450 A required
offset > 275 A
required
Minimum cross-section in the main circuit at mm2 95 150 240 300 370
maximum AC-1 rated value

4/28 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A

■ Selection and ordering data


AC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

4
3RT231.-1A.00 3RT231.-2A.00 3RT232.-1A.00 3RT232.-2A.00 3RT233.-1A.00 3RT234.-1A.00

Rated data AC-1, Auxiliary contacts Rated control supply Screw terminals Spring-loaded terminals
tu: 40/60 °C voltage Us
Operational current Ie Ident. No. Version 50/60 Hz AC 50 Hz AC
up to Article No. Price Article No. Price
690 V per PU per PU

A NO NC V V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
18/16 -- -- -- 24 -- 3RT2316-1AB00 3RT2316-2AB00
110 -- 3RT2316-1AF00 3RT2316-2AF00
230 3RT2316-1AP00 3RT2316-2AP00
22/20 -- -- -- 24 -- 3RT2317-1AB00 3RT2317-2AB00
110 -- 3RT2317-1AF00 3RT2317-2AF00
230 -- 3RT2317-1AP00 3RT2317-2AP00
Size S0
35/301) 11 1 1 -- 24 3RT2325-1AB00 3RT2325-2AB00
-- 110 3RT2325-1AF00 3RT2325-2AF00
-- 230 3RT2325-1AP00 3RT2325-2AP00
40/351) 11 1 1 -- 24 3RT2326-1AB00 3RT2326-2AB00
-- 110 3RT2326-1AF00 3RT2326-2AF00
-- 230 3RT2326-1AP00 3RT2326-2AP00
50/421) 11 1 1 -- 24 3RT2327-1AB00 3RT2327-2AB00
-- 110 3RT2327-1AF00 3RT2327-2AF00
-- 230 3RT2327-1AP00 3RT2327-2AP00
Size S2
60/55 11 1 1 -- 24 3RT2336-1AB00 --
-- 110 3RT2336-1AF00 --
-- 230 3RT2336-1AP00 --
110/95 11 1 1 -- 24 3RT2337-1AB00 --
-- 110 3RT2337-1AF00 --
-- 230 3RT2337-1AP00 --
For screw fixing and snap-on mounting on TH 35-15 and TH 75-15
DIN rails
Size S3
110/100 11 1 1 -- 24 3RT2344-1AB00 --
-- 110 3RT2344-1AF00 --
-- 230 3RT2344-1AP00 --
140/130 11 1 1 -- 24 3RT2346-1AB00 --
-- 110 3RT2346-1AF00 --
-- 230 3RT2346-1AP00 --
160/140 11 1 1 -- 24 3RT2348-1AB00 --
-- 110 3RT2348-1AF00 --
-- 230 3RT2348-1AP00 --
1) Required conductor cross-section 10 mm2. Other voltages according to page 4/52 on request.
Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/29
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A AC-3e
AC operation
Version for AC-3 and AC-3e motor loads
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
4

3RT2326-1AP00-4AA0 3RT2336-1AP00-4AA0 3RT2346-1AP00-4AA0

Rated data Auxiliary contacts Rated control Screw terminals Spring-loaded terminals
AC-3/AC-3e, AC-1, supply
tu: up to 60 °C tu: 40/60 °C voltage Us
Operational Operational Ident. No. Version 50 Hz AC
current Ie current Ie Article No. Price Article No. Price
up to up to per PU per PU
400 V 690 V

A A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S0
32 40/35 11 1 1 230 3RT2326-1AP00-4AA0 --

Size S2
50 60/55 11 1 1 230 3RT2336-1AP00-4AA0 --

For screw fixing and snap-on mounting on TH 35-15 and TH 75-15


DIN rails
Size S3
95 110/100 11 1 1 230 3RT2346-1AP00-4AA0 --

Other voltages according to page 4/52 on request.


Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


4/30 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A
DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

4
3RT231.-1B.40 3RT231.-2B.40 3RT232.-1B.40 3RT232.-2B.40
Rated data Auxiliary contacts Rated control supply Screw terminals Spring-loaded terminals
AC-1, tu: 40/60 °C voltage Us
Operational current Ie Ident. No. Version DC
up to Article No. Price Article No. Price
690 V per PU per PU

A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
18/16 -- -- -- 24 3RT2316-1BB40 3RT2316-2BB40
220 3RT2316-1BM40 3RT2316-2BM40
22/20 -- -- -- 24 3RT2317-1BB40 3RT2317-2BB40
220 3RT2317-1BM40 3RT2317-2BM40
Size S0
35/301) 11 1 1 24 3RT2325-1BB40 3RT2325-2BB40
220 3RT2325-1BM40 3RT2325-2BM40
40/351) 11 1 1 24 3RT2326-1BB40 3RT2326-2BB40
220 3RT2326-1BM40 3RT2326-2BM40
50/421) 11 1 1 24 3RT2327-1BB40 3RT2327-2BB40
220 3RT2327-1BM40 3RT2327-2BM40
1)
Required conductor cross-section 10 mm2. Other voltages according to page 4/52 on request.
Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/31
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A
AC/DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
4

3RT233.-1N.30 3RT234.-1N.30
Rated data Auxiliary contacts Rated control supply Screw terminals Spring-loaded terminals
AC-1, tu: 40/60 °C voltage Us
Operational current Ie Ident. No. Version 50/60 Hz AC or DC
up to Article No. Price Article No. Price
690 V per PU per PU

A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S2
With integrated coil circuit
(varistor integrated in electronics at the factory)
60/55 11 1 1 20 ... 33 3RT2336-1NB30 --
175 ... 280 3RT2336-1NP30 --
110/95 11 1 1 20 ... 33 3RT2337-1NB30 --
175 ... 280 3RT2337-1NP30 --
For screw fixing and snap-on mounting on TH 35-15 and
TH 75-15 DIN rails
Size S3
With integrated coil circuit
(varistor integrated in electronics at the factory)
110/100 11 1 1 20 ... 33 3RT2344-1NB30 --
175 ... 280 3RT2344-1NP30 --
140/130 11 1 1 20 ... 33 3RT2346-1NB30 --
175 ... 280 3RT2346-1NP30 --
160/140 11 1 1 20 ... 33 3RT2348-1NB30 --
175 ... 280 3RT2348-1NP30 --

Other voltages according to page 4/52 on request.


Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


4/32 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
AC-3e SIRIUS 3RT.3 contactors, 4-pole, up to 525 A
AC/DC operation
Version for AC-3 and AC-3e motor loads
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

4
3RT2336-1NB30-4AA0 3RT2346-1NB30-4AA0
Rated data Auxiliary contacts Rated control supply Screw terminals Spring-loaded terminals
AC-3/AC-3e, AC-1, Ident. No. Version voltage Us
tu: up to tu: 40/60 °C 50/60 Hz AC or DC
60 °C
Operational Operational Article No. Price Article No. Price
current Ie current Ie per PU per PU
up to up to
400 V 690 V
A A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S2
With integrated coil circuit
(varistor integrated in electronics at the factory)
50 60/55 11 1 1 20 ... 33 3RT2336-1NB30-4AA0 --

For screw fixing and snap-on mounting on TH 35-15 and


TH 75-15 DIN rails
Size S3
With integrated coil circuit
(varistor integrated in electronics at the factory)
95 110/100 11 1 1 20 ... 33 3RT2346-1NB30-4AA0 --

Other voltages according to page 4/52 on request.


Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/33
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A
Sizes S6 to S12: AC/DC operation
• Solid-state operating mechanism • For screw fixing
• Version with two laterally mounted auxiliary switches • Auxiliary and control circuits: Screw terminals
(2 NO + 2 NC each) • Main conductors: Busbar connections;
a connection kit is enclosed.
4

3RT1355-6A.36 3RT1363-6A.36 3RT1373-6A.36


Size Rated data Auxiliary Operating range Busbar connections PU PS* PG
AC-1, tu: 40 °C contacts, 0.85 ... 1.1 x Us 0.8 ... 1.1 x Us (UNIT,
lateral SET, M)
Rated control supply voltage Us
Operational Version 50/60 Hz AC DC
current Ie Article No. Price
at per PU
690 V

A NO NC V V
Solid-state operating mechanism
With integrated coil circuit (varistor integrated in electronics at the factory)
S6 200 2 2 24 ... 60 20 ... 60 3RT1355-6AE36 1 1 unit 41B
48 ... 130 48 ... 130 3RT1355-6AF36 1 1 unit 41B
100 ... 250 100 ... 250 3RT1355-6AP36 1 1 unit 41B
250 ... 500 250 ... 500 3RT1355-6AR36 1 1 unit 41B
S10 275 2 2 24 ... 60 20 ... 60 3RT1363-6AE36 1 1 unit 41B
48 ... 130 48 ... 130 3RT1363-6AF36 1 1 unit 41B
100 ... 250 100 ... 250 3RT1363-6AP36 1 1 unit 41B
250 ... 500 250 ... 500 3RT1363-6AR36 1 1 unit 41B
350 2 2 24 ... 60 20 ... 60 3RT1364-6AE36 1 1 unit 41B
48 ... 130 48 ... 130 3RT1364-6AF36 1 1 unit 41B
100 ... 250 100 ... 250 3RT1364-6AP36 1 1 unit 41B
250 ... 500 250 ... 500 3RT1364-6AR36 1 1 unit 41B
S12 400 2 2 24 ... 60 20 ... 60 3RT1373-6AE36 1 1 unit 41B
48 ... 130 48 ... 130 3RT1373-6AF36 1 1 unit 41B
100 ... 250 100 ... 250 3RT1373-6AP36 1 1 unit 41B
250 ... 500 250 ... 500 3RT1373-6AR36 1 1 unit 41B
500 2 2 24 ... 60 20 ... 60 3RT1374-6AE36 1 1 unit 41B
48 ... 130 48 ... 130 3RT1374-6AF36 1 1 unit 41B
100 ... 250 100 ... 250 3RT1374-6AP36 1 1 unit 41B
250 ... 500 250 ... 500 3RT1374-6AR36 1 1 unit 41B
525 2 2 24 ... 60 20 ... 60 3RT1375-6AE36 1 1 unit 41B
48 ... 130 48 ... 130 3RT1375-6AF36 1 1 unit 41B
100 ... 250 100 ... 250 3RT1375-6AP36 1 1 unit 41B
250 ... 500 250 ... 500 3RT1375-6AR36 1 1 unit 41B

Depending on the operational current, bus connectors offset Accessories and spare parts, see page 4/35 onwards.
must be used for sizes S10 and S12, see page 4/35:
• 3RT136: For more than 275 A, the 3RT1966-4D bus
connectors offset must be used.
• 3RT137: For more than 450 A, the 3RT1976-4D bus
connectors offset must be used.

* You can order this quantity or a multiple thereof.


4/34 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A

■ Accessories
Overview graphic for 3RT135 to 3RT137 contactors with
mountable accessories, see page 4/23. More information
Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60306557

For contactors Auxiliary contacts Article No. Price PU PS* PG


Version per PU (UNIT,
SET, M)

Type NO NC Left Right

4
Second auxiliary switch (1 NO + 1 NC)
Lateral mounting on the right and/or the left, 2-pole Screw terminals

3RT135 ... 1 1 53 61 71 83 3RH1951-1SA11 1 1 unit 41B


3RT137

54 62 72 84
3RH1951-1SA11
Terminal covers
Two units required per contactor (1 set = 2 units)
Either bus connectors offset or terminal covers can be used.
3RT135 -- -- -- -- 3RT1956-4EB10 1 1 unit 41B
3RT136 -- -- -- -- 3RT1966-4EB10 1 1 unit 41B
3RT1956-4EB10
3RT137 -- -- -- -- 3RT1976-4EB10 1 1 unit 41B

3RT1966-4EB10

3RT1976-4EB10
Bus connectors offset
(Two units required per contactor)
Either terminal covers or bus connectors offset can be used.
3RT136 -- -- -- -- 3RT1966-4D 1 1 unit 41B
3RT1966-4D 3RT137 -- -- -- -- 3RT1976-4D 1 1 unit 41B

3RT1976-4D
Mechanical interlocks for contactor assemblies
Enables two 3RT13 contactors of the same size (S6, S10 and S12)
to be interlocked with each other. The laterally mounted auxiliary
switches of the contactor must be removed beforehand.
The mechanical interlock cannot be used in conjunction with the
bus connectors offset.
3RA1954-3A 3RT135 ... -- -- -- -- 3RA1954-3A 1 1 unit 41B
3RT137

■ Spare parts
For contactors Auxiliary contacts Screw terminals PU PS* PG
Version (UNIT,
SET, M)
Article No. Price
per PU

Type NO NC Left Right


First auxiliary switch (1 NO + 1 NC)
Lateral mounting on the right and/or the left, 2-pole
3RT135 ... 1 1 13 21 31 43 3RH1951-1TA11 1 1 unit 41B
3RT137

14 22 32 44
3RH1951-1TA11

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/35
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT25 contactors, 4-pole, 2 NO + 2 NC

■ Overview
Standards Protection against overvoltage at the control supply voltage
connection
IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1 (auxiliary switches)
3RT25 contactors supplied without a coil circuit can be
Protecting connections against short circuit, overload and retrofitted with RC elements, varistors, diodes or diode
overvoltage assemblies (combination of diode and Zener diode for short
All connections must generally be protected against overload break times) for damping switching overvoltages in the coil and
and short circuits using suitable measures. Different constraints can be ordered separately as accessories, see page 3/97
must be considered depending on the type of connection: onwards.
Short-circuit and overload protection of main connections Note:
For information on the protection of a free-standing contactor, The break times of the contactor, the opening delay times of the
4

see the technical product data sheet. NO contacts and the closing delay times of the NC contacts
increase with damping.
For more information on complete units such as contactors with
overload relays or contactors with motor starter protectors as the For more information about influencing the time response using
motor feeder, see Configuration Manual for load feeders. damping, see Equipment Manual.
Short-circuit and overload protection of auxiliary connections Replacing solenoid coils or spare contacts
For information on the protection of auxiliary contacts, see the Solenoid coil or contact replacement is possible.
technical product data sheet.
Fitting auxiliary contacts and mounting additional auxiliary
Short-circuit and overload protection of control supply voltage switches
connections or supply voltage connections
Features in the delivery state
First of all, the relevant standards and regulations for configuring
control panels and the parts and components installed in them The 3RT252 to 3RT254 basic units contain two integrated
must be taken into account, for example for cable dimensioning. auxiliary contacts (1 NO + 1 NC).

One possible protection for these circuits could be the selection Expansion possibilities
of a suitable power supply, i.e. one with a current-limiting All basic units can be expanded using auxiliary switches;
function. In the selection of the source and the connecting cable, the permissible configuration must be observed.
the load characteristics of the contactor must be considered
(short-time inrush current peaks for solid-state operating For detailed information about the fitting of auxiliary switches for
mechanisms, switch-on power, holding power). 3RT25 contactors, see pages 3/81 to 3/86.

If there are further switching elements in the circuit, such as the Accessories
auxiliary contact system of an overload relay that operates the The accessories for the 3-pole SIRIUS 3RT2 contactors can also
contactor, the short-circuit protection necessary for this must be used for the 4-pole versions, see page 3/69 onwards.
also be considered.
Use of 3RT contactors with IE3 and IE4 motors
For further recommendations, e.g. the use of miniature circuit
breakers or circuit breakers for equipment in control circuits, see Note:
Control panel tip – Selecting and dimensioning suitable power
supplies quickly and reliably. For the use of 3RT25 contactors in conjunction with highly
efficient IE3 and IE4 motors, please observe the information on
dimensioning and configuring, see Application Manual.
More information, see page 1/8.

■ Application
The contactors are suitable: Note:
• For changing the polarity of hoisting gear motors Single device for pole reversal; not suitable for reversing operation.
• For switching two separate loads 3RT25 contactors are not suitable for switching a load between two
current sources.

4/36 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT25 contactors, 4-pole, 2 NO + 2 NC

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/16169/td https://support.industry.siemens.com/cs/ww/en/ps/16169/man
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16169/faq

Type 3RT2516 to 3RT2518 3RT2526 3RT2535 3RT2536 3RT2544, 3RT2545


Size S00 S0 S2 S3
General data
Dimensions (W x H x D) See 3RT231., See 3RT232., See 3RT233., See 3RT234.,
page 4/24 page 4/24 page 4/24 page 4/24

4
Permissible mounting position
The contactors are designed for operation

NSB0_00478c
360° 22,5° 22,5°
on a vertical mounting surface.

Upright mounting position

NSB0_00477a

Special version required


Mechanical endurance Operating 30 million 10 million
cycles
Electrical endurance at Ie/AC-1 Operating Approx. 0.5 million
cycles
Rated insulation voltage Ui V 690
(pollution degree 3)
Protective separation between the coil and the V 400 690
main contacts according to IEC 60947-1, Annex N
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -55 ... +80
Short-circuit protection
Main circuit
• Version of the fuse link required for short-circuit
protection of the main circuit
- For type of coordination 1 gG: 35 A gG: 63 A gG: 125 A gG: 160 A gG: 250 A
(690 V, 100 kA) (690 V, 100 kA) (690 V, (690 V, (690 V, 100 kA)
100 kA) 100 kA)
- For type of coordination 2 gG: 20 A gG: 35 A gG: 63 A gG: 80 A gR: 250 A
(690 V, 100 kA) (690 V, 50 kA) (690 V, (690 V, (690 V, 100 kA)
100 kA) 100 kA)
Auxiliary circuit
• Version of the fuse link required for short-circuit Fuse gG: 10 A (690 V, 1 kA)
protection of the auxiliary switch
• Version of the miniature circuit breaker required 6 A (230 V, 400 A, C characteristic)
for short-circuit protection of the auxiliary switch

Siemens IC 10 · 2023 4/37


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT25 contactors, 4-pole, 2 NO + 2 NC

Type 3RT2516- 3RT2517-1A, 3RT2516-1B, 3RT2526- 3RT2526- 3RT253.- 3RT253.- 3RT254.- 3RT254.-
1A 3RT2518-1A 3RT2517-1B, 1A 1B 1A 1N 1A 1N
3RT2518-1B
Size S00 S0 S2 S3
Control
Type of operating mechanism AC DC AC DC AC AC/DC AC AC/DC
Solenoid coil operating range
• AC operation At 50 Hz 0.8 ... -- 0.8 ... -- 0.8 ... -- 0.8 ... --
1.1 x Us 1.1 x Us 1.1 x Us 1.1 x Us
At 60 Hz 0.85 ... -- 0.8 ... -- 0.8 ... -- 0.8 ... --
1.1 x Us 1.1 x Us 1.1 x Us 1.1 x Us
• DC operation Up to 50 °C -- 0.8 ... -- 0.8 ... --
1.1 x Us 1.1 x Us
4

Up to 60 °C -- 0.85 ... -- 0.8 ... --


1.1 x Us 1.1 x Us
• AC/DC operation -- 0.8 x Us min -- 0.8 x Us min
... ...
1.1 x Us max 1.1 x Us max
Power consumption of the
solenoid coils
(for cold coil and 1.0 x Us)
• AC operation, 50/60 Hz,
standard version
- Closing VA 27/24.3 37/33 -- 81/79 -- 210/188 110 348/296 --
- P.f.  0.8/0.75 -- 0.72/0.74 -- 0.69/0.65 0.95 0.62/0.55 --
- Closed VA 4.2/3.3 5.7/4.4 -- 10.5/8.5 -- 17.2/16.5 2.5 25/18 --
- P.f.  0.25/0.25 -- 0.25/0.28 -- 0.36/0.39 0.95 0.35/0.41 --
• DC operation
- Closing W -- 4 -- 5.9 23 70 -- 76
- Closed W -- 4 -- 5.9 1 1.5 -- 1.8

Type 3RT2516 3RT2517 3RT2518 3RT2526 3RT2535 3RT2536 3RT2544 3RT2545


Size S00 S0 S2 S3
Rated data of the main contacts
Load rating with AC
Utilization category AC-1
• Rated operational At 40 °C up to 690 V A 18 22 40 60 70 100 125
currents Ie At 60 °C up to 690 V A 16 20 35 55 60 90 105
• Rated power for AC loads At 230 V kW 6 7.5 13.3 21 23 34 59
P.f. = 0.95 (at 60 °C) 400 V kW 10.5 13 23 36 39 40 69
2
• Minimum cross-section in mm 2.5 4 10 16 25 35 50
the main circuit at maximum
AC-1 rated value
Utilization category AC-3 AC1) DC1)
• Rated operational NO up to 400 V A 9 12 16 25 35 41 65 80
currents Ie NC up to 400 V A 9 25 20 35 41 65 80
(at 60 °C)
• Rated power for slip-ring or NO at 230 V kW 2.2 3 4 5.5 11 18.5 22
squirrel-cage motors NC at 230 V kW 2.2 5.5 11 18.5 22
at 50 and 60 Hz NO at 400 V kW 4 5.5 7.5 11 18.5 22 30 37
NC at 400 V kW 4 11 7.5 18.5 22 30 37
1)
Values for devices with AC and DC operation: For 3RT2526 with DC
operation, different values apply to AC-3 for the NC.

4/38 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT25 contactors, 4-pole, 2 NO + 2 NC

■ Selection and ordering data


AC operation
Single device for pole reversal (not suitable for reversing operation)
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

4
3RT251.-1A.00 3RT251.-2A.00 3RT252.-1A.00 3RT252.-2A.00 3RT253.-1A.00 3RT254.-1A.00

Rated data Auxiliary Rated control supply Screw terminals Spring-loaded terminals
contacts voltage Us
AC-3, AC-1, Ident. Version 50/60 Hz AC 50 Hz AC
tu: up to 60 °C tu: 40/60 °C No.
Opera- Ratings of Operational Article No. Price Article No. Price
tional three-phase current Ie per PU per PU
current Ie motors up to
up to at 50 Hz and
400 V 400 V 690 V
A kW A NO NC V V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
9 4 18/16 -- -- -- 24 -- 3RT2516-1AB00 3RT2516-2AB00
110 -- 3RT2516-1AF00 3RT2516-2AF00
230 -- 3RT2516-1AP00 3RT2516-2AP00
12/91) 5.5/41) 22/20 -- -- -- 24 -- 3RT2517-1AB00 3RT2517-2AB00
110 -- 3RT2517-1AF00 3RT2517-2AF00
230 -- 3RT2517-1AP00 3RT2517-2AP00
16/91) 7.5/41) 22/20 -- -- -- 24 -- 3RT2518-1AB00 3RT2518-2AB00
110 -- 3RT2518-1AF00 3RT2518-2AF00
230 -- 3RT2518-1AP00 3RT2518-2AP00
Size S0
25 11 40/35 11 1 1 -- 24 3RT2526-1AB00 3RT2526-2AB00
-- 110 3RT2526-1AF00 3RT2526-2AF00
-- 230 3RT2526-1AP00 3RT2526-2AP00
Size S2
35 18.5 60/55 11 1 1 -- 24 3RT2535-1AB00 --
-- 110 3RT2535-1AF00 --
-- 230 3RT2535-1AP00 --
41 22 70/60 11 1 1 -- 24 3RT2536-1AB00 --
-- 110 3RT2536-1AF00 --
-- 230 3RT2536-1AP00 --
For screw fixing and snap-on mounting on TH 35-15 and
TH 75-15 DIN rails
Size S3
65 30 100/90 11 1 1 -- 24 3RT2544-1AB00 --
-- 110 3RT2544-1AF00 --
-- 230 3RT2544-1AP00 --
80 37 125/105 11 1 1 -- 24 3RT2545-1AB00 --
-- 110 3RT2545-1AF00 --
-- 230 3RT2545-1AP00 --
1)
Values for NO contact/NC contact. The NC contact can switch no more Other voltages according to page 4/52 on request.
than 4 kW.
Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/39
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT25 contactors, 4-pole, 2 NO + 2 NC
DC operation
Single device for pole reversal (not suitable for reversing operation)
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B
4

3RT251.-1B.40 3RT251.-2B.40 3RT252.-1B.40 3RT252.-2B.40


Rated data Auxiliary Rated control Screw terminals Spring-loaded terminals
contacts supply voltage Us
AC-3, AC-1, Ident. Version DC
tu: up to 60 °C tu: 40/60 °C No.
Opera- Ratings of Operational Article No. Price Article No. Price
tional three-phase current Ie per PU per PU
current Ie motors up to
up to at 50 Hz and
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
9 4 18/16 -- -- -- 24 3RT2516-1BB40 3RT2516-2BB40
220 3RT2516-1BM40 3RT2516-2BM40
12/91) 5.5/41) 22/20 -- -- -- 24 3RT2517-1BB40 3RT2517-2BB40
220 3RT2517-1BM40 3RT2517-2BM40
16/91) 7.5/41) 22/20 -- -- -- 24 3RT2518-1BB40 3RT2518-2BB40
220 3RT2518-1BM40 3RT2518-2BM40
Size S0
25 (20)2) 11 (7.5)2) 40/35 11 1 1 24 3RT2526-1BB40 3RT2526-2BB40
220 3RT2526-1BM40 3RT2526-2BM40
1)
Values for NO contact/NC contact. The NC contact can switch no more Other voltages according to page 4/52 on request.
than 4 kW.
2) Value in brackets for NC contact (the deviating value for the NC contact Accessories and spare parts, see page 3/69 onwards.
applies only for devices with DC operation).

* You can order this quantity or a multiple thereof.


4/40 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT25 contactors, 4-pole, 2 NO + 2 NC
AC/DC operation
Single device for pole reversal (not suitable for reversing operation)
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41B

4
3RT253.-1N.30 3RT254.-1N.30
Rated data Auxiliary Rated control Screw terminals Spring-loaded terminals
contacts supply voltage Us
AC-3, AC-1, Ident. Version 50/60 Hz AC
tu: up to 60 °C tu: 40/60 °C No. or DC
Opera- Ratings of Operational Article No. Price Article No. Price
tional three-phase current Ie per PU per PU
current motors up to
Ie up to at 50 Hz and
400 V 400 V 690 V
A kW A NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S2
With integrated coil circuit (varistor integrated in electronics at the factory)
35 18.5 60/55 11 1 1 20 ... 33 3RT2535-1NB30 --
83 ... 155 3RT2535-1NF30 --
175 ... 280 3RT2535-1NP30 --
41 22 70/60 11 1 1 20 ... 33 3RT2536-1NB30 --
83 ... 155 3RT2536-1NF30 --
175 ... 280 3RT2536-1NP30 --
For screw fixing and snap-on mounting on TH 35-15 and
TH 75-15 DIN rails
Size S3
With integrated coil circuit (varistor integrated in electronics at the factory)
65 30 100/90 11 1 1 20 ... 33 3RT2544-1NB30 --
175 ... 280 3RT2544-1NP30 --
80 37 125/105 11 1 1 20 ... 33 3RT2545-1NB30 --
175 ... 280 3RT2545-1NP30 --

Other voltages according to page 4/52 on request.


Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/41
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole

■ Overview
Standards Protection against overvoltage at the control supply voltage
connection
IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1, IEC 60831-1,
IEC 61921 3RT26 contactors supplied without a coil circuit can be
retrofitted with RC elements, varistors, diodes or diode
Function assemblies (combination of diode and Zener diode for short
The 3RT26 contactors are special versions of the 3RT2, break times) for damping switching overvoltages in the coil and
designed for switching capacitive loads (AC-6b) up to 100 kvar can be ordered separately as accessories, see page 3/97
at 400 V. onwards.
Characteristic components of the 3RT26 contactors are the Note:
precharging resistors switched on via leading auxiliary contacts, The break times of the contactor, the opening delay times of the
which are closed before the main contacts. This limits the peak
4

NO contacts and the closing delay times of the NC contacts


charging current of capacitive loads and thus minimizes increase with damping.
negative impacts on the power supply network.
For more information about influencing the time response using
The 3RT26 contactors are suitable for switching choked or damping, see Equipment Manual.
unchoked capacitors in reactive current compensation systems
and are also used to switch converters. Fitting auxiliary contacts and mounting additional auxiliary
switches
Protecting connections against short circuit, overload and
overvoltage Features in the delivery state
All connections must generally be protected against overload • 3RT261 contactors:
and short circuits using suitable measures. Different constraints The basic units are equipped with a 4-pole front-mounted
must be considered depending on the type of connection: auxiliary switch with one freely accessible contact. The other
three contacts are assigned to the precharging resistors.
Short-circuit and overload protection of main connections Additional free auxiliary contacts are provided in the basic unit
For information on the protection of a free-standing contactor, (depending on the version, 1 NO + 1 NC or 2 NO).
see the technical product data sheet. • 3RT262 contactors:
The basic units are equipped with a 4-pole front-mounted
For more information on complete units such as contactors with auxiliary switch with one freely accessible contact. The other
overload relays or contactors with motor starter protectors as the three contacts are assigned to the precharging resistors.
motor feeder, see Configuration Manual for load feeders. Two additional free auxiliary contacts are provided in the basic
Short-circuit and overload protection of auxiliary connections unit (1 NO + 1 NC).
For information on the protection of auxiliary contacts, see the • 3RT263 and 3RT264 contactors:
technical product data sheet. The auxiliary contacts for the resistors are already integrated
in the basic units, which do not have any additional integrated
Short-circuit and overload protection of control supply voltage and freely assignable auxiliary contacts. A 2-pole lateral
connections or supply voltage connections auxiliary switch is already mounted on the left (depending on
the version, 1 NO + 1 NC or 2 NC).
First of all, the relevant standards and regulations for configuring
control panels and the parts and components installed in them Expansion possibilities
must be taken into account, for example for cable dimensioning.
All 3RT263 and 3RT264 contactors can be expanded using
One possible protection for these circuits could be the selection lateral auxiliary switches; the permissible configuration must
of a suitable power supply, i.e. one with a current-limiting be observed.
function. In the selection of the source and the connecting cable,
the load characteristics of the contactor must be considered Type 3RT261 3RT262 3RT263, 3RT264
(short-time inrush current peaks for solid-state operating Size S00 S0 S2, S3
mechanisms, switch-on power, holding power). Number of unassigned auxiliary 2 3 2
contacts as delivered from the
If there are further switching elements in the circuit, such as the factory
auxiliary contact system of an overload relay that operates the Number of expansion auxiliary 0 0 2
contactor, the short-circuit protection necessary for this must contacts that can be fitted
also be considered.
Conductor cross-sections
For further recommendations, e.g. the use of miniature circuit
breakers or circuit breakers for equipment in control circuits, see In order to connect the required minimum cross-section, the use
Control panel tip – Selecting and dimensioning suitable power of 3RV2935-5A 3-phase infeed terminal may be necessary for
supplies quickly and reliably. 3RT263 contactors and of 3RA2943-3L 1-phase infeed terminal
for 3RT264 contactors, see page 3/110. These infeed terminals
enable the clamping of larger cross-sections than the device
connection itself actually allows.
For 3RT2628 contactors, this infeed terminal is included in the
scope of supply and is mounted on the contactor.

4/42 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/16171/td https://support.industry.siemens.com/cs/ww/en/ps/16171/man

Type 3RT26
Size S00 to S3
Contact endurance of the main contacts
The characteristic curves show the contact endurance of the contactors
when switching capacitive loads (AC-6b) depending on the reactive 10+6 IC01_00386d
power QN and the rated operational voltage. 8

Electrical endurance (operating cycles)


The rated operational current Ie complies with utilization category AC-6b 6

4
(breaking of 1.35 times the rated operational current) and is intended for 4 3RT2617
a contact endurance of approximately 150 000 to 200 000 operating cycles.
3RT2625
2 3RT2626
3RT2627
10+5 3RT2628
3RT2636
3RT2637
3RT2645
3RT2646

10+4
100 2 4 6 8 101 2 4 6 8 102 2
Reactive power N
[kvar] at 400 V

1,4 2,9 5,8 14 28 144


Reactive current a AC-6b [A]

Siemens IC 10 · 2023 4/43


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole
All technical specifications not mentioned in the table below are
identical to those of the 3RT20 contactors:
• For size S00 as for the 3RT201 contactors
• For size S0 as for the 3RT202 contactors
• For size S2 as for the 3RT203 contactors
• For size S3 as for the 3RT204 contactors
See page 3/25 onwards.
Type 3RT2617 3RT2625 3RT2626 3RT2627 3RT2628 3RT2636 3RT2637 3RT2645 3RT2646
Size S00 S0 S2 S3
General data
Dimensions (W x H x D)
4

Including auxiliary switches


and connecting cables
H

• AC operation mm 45 x 125 x 45 x 135 x 155 45 x 150 x 65 x 114 x 130 80 x 140 x 152


120 155
D

W
• DC operation, mm 45 x 125 x 45 x 135 x 165 45 x 150 x 65 x 114 x 130 80 x 140 x 152
AC/DC operation 120 165
Permissible mounting position

NSB0_00478c
360° 22,5° 22,5°
The contactors are designed for operation on
a vertical mounting surface.

Mechanical endurance
Basic units with mounted auxiliary switch Operat- 3 million
ing
cycles
Electrical endurance kvar 12.5 16.7 20 25 33 50 75 100
For apparent power at 400 V Operat- 300 000 200 000 150 000 200 000 150 000 200 000 150 000
ing
cycles
Rated insulation voltage Ui V 690 1 0002)
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 6 82)
Protective separation V 400 690
between the coil and the main contacts
according to IEC 60947-1, Annex N
Permissible ambient temperature
• During operation1) °C -25 ... +60
• During storage °C -55 ... +80
Short-circuit protection
Main circuit
Fuse links, operational class gG:
LV HRC, type 3NA; DIAZED, type 5SB;
NEOZED, type 5SE
according to IEC 60947-4-1
• Type of coordination "1" A 25 ... 40 32 ... 80 40 ... 80 50 ... 100 63 ... 100 100 ... 160 160 ... 200 200 ...
250
Auxiliary circuit
• With fuse links of operational class gG: A 10
DIAZED, type 5SB; NEOZED, type 5SE
With short-circuit current Ik = 1 kA
according to IEC 60947-5-1
• With miniature circuit breakers with A 10
C characteristic with short-circuit
current Ik = 400 A
1) A clearance of 10 mm is required for side-by-side mounting. 2) Only applies for main conducting paths, otherwise Ui = 690 V; Uimp = 6 kV.

4/44 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole

Type 3RT2617-1A, -1B 3RT2625-1A, -1B, 3RT2636-1A, 3RT2645-1A,


3RT2626-1A, -1B, 3RT2637-1A 3RT2646-1A
3RT2627-1A, -1B,
3RT2628-1A, -1B
Size S00 S0 S2 S3
Control
Solenoid coil operating range
• AC operation 50 Hz 0.8 ... 1.1 x Us
60 Hz 0.85 ... 1.1 x Us 0.8 ... 1.1 x Us
• DC operation At 50 °C 0.8 ... 1.1 x Us --
At 60 °C 0.85 ... 1.1 x Us 0.8 ... 1.1 x Us --
Power consumption of the solenoid coils
(for cold coil and 1.0 x Us)

4
• AC operation, 50 Hz, standard version
- Closing VA -- 77 190 296
- P.f.  -- 0.82 0.72 0.61
- Closed VA -- 9.8 16 19
- P.f.  -- 0.25 0.37 0.38
• AC operation, 50/60 Hz, standard version
- Closing VA 49 81/79 210/188 348/296
- P.f.  0.8 0.72/0.74 0.69/0.65 0.62/0.55
- Closed VA 7.8 10.5/8.5 17.2/16.5 25/18
- P.f.  0.25 0.25/0.28 0.36/0.39 0.35/0.41
• DC operation
- Closing W 4 5.9 --
- Closed W 4 5.9 --

Type 3RT262.-1NB35 3RT262.-1NF35 3RT262.-1NP35 3RT263.-1N.35 3RT264.-1N.35


Size S0 S2 S3
Control
Solenoid coil operating range
• AC/DC operation 0.7 ... 1.3 x Us 0.8 ... 1.1 x Us
(50/60 Hz AC or DC)
Power consumption of the solenoid coils
(for cold coil and 1.0 x Us)
• AC operation, 50/60 Hz, standard version
- Closing VA 6.6/6.7 11.9/12.0 12.7/14.7 110 163
- P.f.  0.98/0.98 0.95 --
- Closed VA 1.9/2.0 1.6/1.8 3.9/4.3 2.5 3.1
- P.f.  0.86/0.82 0.79/0.74 0.51/0.56 0.95 --
• DC operation
- Closing W 5.9 10.2 14.3 70 76
- Closed W 1.4 1.3 1.9 1.5 1.8
Maximum permissible residual current of the
electronics (with 0 signal)
• AC operation (230 V/Us) mA 7 < 20
• DC operation (24 V/Us) mA 16 < 20

Siemens IC 10 · 2023 4/45


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole

Type 3RT2617 3RT2625 3RT2626 3RT2627 3RT2628 3RT2636 3RT2637 3RT2645 3RT2646
Size S00 S0 S2 S3
Auxiliary circuit
Auxiliary contacts (unassigned) 1 NO + 1 NO + 2 NC 1 NO + 1 NC, 2 NC
1 NC,
2 NC
Further auxiliary switches, -- No more than one lateral auxiliary switch can
laterally mountable be mounted.
Technical specifications including CSA and UL
rated data of the auxiliary contacts, see
"3RT20 contactors", page 3/25 onwards.
Rated data of the main contacts
Load rating with AC
4

Utilization category AC-6b


Switching of AC capacitors
• Rated operational current
Ie at AC-6b
- Up to 690 V at ambient 40 °C A 18.9 25.3 30.2 37.8 50 75.8 113.4 113 151
temperature 60 °C A 18 24 29 36 47.6 72.2 108 144
- Up to 1 000 V at ambient 60 °C A -- 54 68
temperature
• Rated operational reactive 230 V, 50/60 Hz kvar 7.2 9.6 11.5 14 19 29 43 57
power at rated operational 400 V, 50/60 Hz kvar 12.5 16.7 20 25 33 50 75 100
voltage 500 V, 50/60 Hz kvar 15 21 25 31 41 63 94 125
690 V, 50/60 Hz kvar 21 29 34 43 57 86 129 172
1 000 V, 50/60 Hz kvar -- 94 125
• Minimum cross-section in See
the main circuit for max. • Product data sheets of the relevant capacitor contactors and capacitors
AC-6b rated value • Operating instructions and manuals,
https://support.industry.siemens.com/cs/ww/en/ps/16171/man
s and u rated data
Rated insulation voltage V AC 600
Operational reactive 110 ... 120 V kvar 3.4 4.6 5.5 6.3 8.3 14 19 20 25
power at AC-6b, 3-phase, 200 ... 208 V kvar 6.2 8.3 10 11 15 25 34 37 45
at operational voltage 220 ... 230 V kvar 6.9 9.2 11 13 17 27 38 41 50
460 ... 480 V kvar 14 18 22 25 33 55 75 82 100
575 ... 600 V kvar 17 23 27 31 41 69 94 103 125
Short-circuit protection At 600 V kA 5 10
Fuse for main circuit Class RK5 A 40 80 100 250

4/46 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole

Type 3RT2617 3RT2625, 3RT2628 3RT2636 3RT2637 3RT2645,


3RT2626, 3RT2646
3RT2627
Size S00 S0 S2 S3
Conductor cross-sections
Main conductors Screw terminals
(1 or 2 conductors can be
connected)
• Solid or stranded mm2 2 x (0.5 ... 1.5)1); 2 x (1 ... 2.5)1); 2 x (2.5 ... 35); 2 x (10 ... 70);
2 x (0.75 ... 2.5)1); 2 x (2.5 ... 10)1) 1 x (2.5 ... 50) 1 x (10 ... 70)
max. 2 x 4
• Finely stranded with end sleeve mm2 2 x (0.5 ... 1.5)1); 2 x (1 ... 2.5)1); 1 x (2.5 ... 16) 2 x (1 ... 25); -- 2 x (10 ... 50);
(DIN 46228) 2 x (0.75 ... 2.5)1) 2 x (2.5 ... 6)1); 1 x (1 ... 35) 1 x (10 ... 50)
1 x 10

4
• AWG cables, AWG 2 x (20 ... 16)1); 2 x (16 ... 12)1); 1 x (10 ... 4) 2 x (18 ... 2); 2 x (8 ... 3/0);
solid or stranded 2 x (18 ... 14)1); 2 x (14 ... 8)1) 1 x (18 ... 0) 1 x (8 ... 3/0)
2 x 12
• Terminal screw M3 M4 M8 M6 M8
(for Pozidriv size 2; (for Pozidriv size 2; (for Pozidriv size 2; (hexagon socket,
 5 ... 6 mm)  5 ... 6 mm)  5 ... 6 mm) A/F 4)
• Tightening torque Nm 0.8 ... 1.2 2 ... 2.5 3 ... 4 3 ... 4.5 4.5 ... 6
lb.in 7 ... 10.3 18 ... 22 27 ... 36 27 ... 40 40 ... 53
Auxiliary conductors
(1 or 2 conductors can be
connected)
• Solid or stranded mm2 2 x (0.5 ... 1.5)1);
2 x (0.75 ... 2.5)1); max. 2 x 4
• Finely stranded with end sleeve mm2 2 x (0.5 ... 1.5)1);
(DIN 46228) 2 x (0.75 ... 2.5)1)
• AWG cables, AWG 2 x (20 ... 16)1);
solid or stranded 2 x (18 ... 14)1);
2 x 12
• Terminal screw M3
(for Pozidriv size 2;
 5 ... 6 mm)
• Tightening torque Nm 0.8 ... 1.2
lb.in 7 ... 10.3
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in one of the ranges specified.

Siemens IC 10 · 2023 4/47


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole

■ Selection and ordering data


AC operation
Main, auxiliary and control conductors: Screw terminals
4

3RT2617-1A.05 3RT262.-1A.05 3RT2628-1A.05


with infeed terminal
Utilization category AC-6b Auxiliary Rated control supply Screw terminals PU PS* PG
Switching AC capacitors contacts, voltage Us (UNIT,
at an ambient temperature of 60 °C unassigned SET, M)
Version 50 Hz AC 50/60 Hz AC
Capacitor rating at Article No. Price
operational voltage 50/60 Hz per PU
at 230 V at 400 V at 500 V at 690 V
kvar kvar kvar kvar NO NC V V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
7.2 12.5 15 21 1 1 -- 24 3RT2617-1AB03 1 1 unit 41B
-- 110 3RT2617-1AF03 1 1 unit 41B
-- 230 3RT2617-1AP03 1 1 unit 41B
7.2 12.5 15 21 0 2 -- 24 3RT2617-1AB05 1 1 unit 41B
-- 110 3RT2617-1AF05 1 1 unit 41B
-- 230 3RT2617-1AP05 1 1 unit 41B
Size S0
9.6 16.7 21 29 1 2 24 -- 3RT2625-1AB05 1 1 unit 41B
110 -- 3RT2625-1AF05 1 1 unit 41B
230 -- 3RT2625-1AP05 1 1 unit 41B
11.5 20 25 34 1 2 24 -- 3RT2626-1AB05 1 1 unit 41B
110 -- 3RT2626-1AF05 1 1 unit 41B
230 -- 3RT2626-1AP05 1 1 unit 41B
14 25 31 43 1 2 24 -- 3RT2627-1AB05 1 1 unit 41B
110 -- 3RT2627-1AF05 1 1 unit 41B
230 -- 3RT2627-1AP05 1 1 unit 41B
19 33 41 57 1 2 24 -- 3RT2628-1AB05 1 1 unit 41B
110 -- 3RT2628-1AF05 1 1 unit 41B
230 -- 3RT2628-1AP05 1 1 unit 41B

Other voltages according to page 4/52 on request.


Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


4/48 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole
AC operation
Main, auxiliary and control conductors: Screw terminals

4
3RT263.-1A.05 3RT264.-1A.05
Utilization category AC-6b Auxiliary Rated control supply Screw terminals PU PS* PG
Switching AC capacitors contacts, voltage Us (UNIT,
at an ambient temperature of 60 °C unassigned SET, M)
Version 50 Hz AC
Capacitor rating at Article No. Price
operational voltage 50/60 Hz per PU
at 230 V at 400 V at 500 V at 690 V
kvar kvar kvar kvar NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S2
29 50 63 86 1 1 24 3RT2636-1AB03 1 1 unit 41B
110 3RT2636-1AF03 1 1 unit 41B
230 3RT2636-1AP03 1 1 unit 41B
29 50 63 86 0 2 24 3RT2636-1AB05 1 1 unit 41B
110 3RT2636-1AF05 1 1 unit 41B
230 3RT2636-1AP05 1 1 unit 41B
43 75 94 129 1 1 24 3RT2637-1AB03 1 1 unit 41B
110 3RT2637-1AF03 1 1 unit 41B
230 3RT2637-1AP03 1 1 unit 41B
43 75 94 129 0 2 24 3RT2637-1AB05 1 1 unit 41B
110 3RT2637-1AF05 1 1 unit 41B
230 3RT2637-1AP05 1 1 unit 41B
For screw fixing and snap-on mounting on TH 35-15 and TH 75-15 DIN rails
Size S3
43 75 94 129 1 1 24 3RT2645-1AB03 1 1 unit 41B
110 3RT2645-1AF03 1 1 unit 41B
230 3RT2645-1AP03 1 1 unit 41B
43 75 94 129 0 2 24 3RT2645-1AB05 1 1 unit 41B
110 3RT2645-1AF05 1 1 unit 41B
230 3RT2645-1AP05 1 1 unit 41B
57 100 125 172 1 1 24 3RT2646-1AB03 1 1 unit 41B
110 3RT2646-1AF03 1 1 unit 41B
230 3RT2646-1AP03 1 1 unit 41B
57 100 125 172 0 2 24 3RT2646-1AB05 1 1 unit 41B
110 3RT2646-1AF05 1 1 unit 41B
230 3RT2646-1AP05 1 1 unit 41B

Other voltages according to page 4/52 on request.


Accessories, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/49
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole
DC operation
Main, auxiliary and control conductors: Screw terminals
4

3RT2617-1B.45 3RT262.-1B.45 3RT2628-1B.45


with infeed terminal
Utilization category AC-6b Auxiliary Rated control supply Screw terminals PU PS* PG
Switching AC capacitors contacts, voltage Us (UNIT,
at an ambient temperature of 60 °C unassigned SET, M)
Version DC
Capacitor rating at Article No. Price
operational voltage 50/60 Hz per PU
at 230 V at 400 V at 500 V at 690 V
kvar kvar kvar kvar NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
7.2 12.5 15 21 1 1 24 3RT2617-1BB43 1 1 unit 41B
110 3RT2617-1BF43 1 1 unit 41B
7.2 12.5 15 21 0 2 24 3RT2617-1BB45 1 1 unit 41B
110 3RT2617-1BF45 1 1 unit 41B
Size S0
9.6 16.7 21 29 1 2 24 3RT2625-1BB45 1 1 unit 41B
110 3RT2625-1BF45 1 1 unit 41B
11.5 20 25 34 1 2 24 3RT2626-1BB45 1 1 unit 41B
110 3RT2626-1BF45 1 1 unit 41B
14 25 31 43 1 2 24 3RT2627-1BB45 1 1 unit 41B
110 3RT2627-1BF45 1 1 unit 41B
19 33 41 57 1 2 24 3RT2628-1BB45 1 1 unit 41B
110 3RT2628-1BF45 1 1 unit 41B

Other voltages according to page 4/52 on request.


Accessories, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


4/50 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole
AC/DC operation
Main, auxiliary and control conductors: Screw terminals

4
3RT262.-1N.35 3RT2628-1N.35 3RT263.-1N.35 3RT264.-1N.35
with infeed terminal
Utilization category AC-6b Auxiliary Rated control supply Screw terminals PU PS* PG
Switching AC capacitors contacts, voltage Us (UNIT,
at an ambient temperature of 60 °C unassigned SET, M)
Version 50/60 Hz AC or DC
Capacitor rating at Article No. Price
operational voltage 50/60 Hz per PU
at 230 V at 400 V at 500 V at 690 V
kvar kvar kvar kvar NO NC V
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S0
9.6 16.7 21 29 1 2 21 ... 28 3RT2625-1NB35 1 1 unit 41B
95 ... 130 3RT2625-1NF35 1 1 unit 41B
200 ... 280 3RT2625-1NP35 1 1 unit 41B
11.5 20 25 34 1 2 21 ... 28 3RT2626-1NB35 1 1 unit 41B
95 ... 130 3RT2626-1NF35 1 1 unit 41B
200 ... 280 3RT2626-1NP35 1 1 unit 41B
14 25 31 43 1 2 21 ... 28 3RT2627-1NB35 1 1 unit 41B
95 ... 130 3RT2627-1NF35 1 1 unit 41B
200 ... 280 3RT2627-1NP35 1 1 unit 41B
19 33 41 57 1 2 21 ... 28 3RT2628-1NB35 1 1 unit 41B
95 ... 130 3RT2628-1NF35 1 1 unit 41B
200 ... 280 3RT2628-1NP35 1 1 unit 41B
Size S2
29 50 63 86 0 2 20 ... 33 3RT2636-1NB35 1 1 unit 41B
83 ... 155 3RT2636-1NF35 1 1 unit 41B
175 ... 280 3RT2636-1NP35 1 1 unit 41B
43 75 94 129 0 2 20 ... 33 3RT2637-1NB35 1 1 unit 41B
83 ... 155 3RT2637-1NF35 1 1 unit 41B
175 ... 280 3RT2637-1NP35 1 1 unit 41B
For screw fixing and snap-on mounting on TH 35-15 and TH 75-15 DIN rails
Size S3
43 75 94 129 0 2 20 ... 33 3RT2645-1NB35 1 1 unit 41B
83 ... 155 3RT2645-1NF35 1 1 unit 41B
175 ... 280 3RT2645-1NP35 1 1 unit 41B
57 100 125 172 0 2 20 ... 33 3RT2646-1NB35 1 1 unit 41B
83 ... 155 3RT2646-1NF35 1 1 unit 41B
175 ... 280 3RT2646-1NP35 1 1 unit 41B

Other voltages according to page 4/52 on request.


Accessories, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/51
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT23 to 3RT26, 3RT14 contactors

■ Options
Rated control supply voltages for 3RT2 contactors, possible on request
(change of the 10th and 11th digits of the article number)
Delivery time on request
Rated control supply Contactor type 3RT231, 3RT232, 3RT233, 3RT234, 3RT2617,
voltage Us 3RT251 3RT252 3RT253 3RT244, 3RT262, 3RT263,
3RT254 3RT264
Size S00 S0 S2 S3 S00 to S3
Sizes S00 to S3
AC operation1)
Solenoid coils for 50 Hz
(exception: Size S00: 50 and 60 Hz2))
4

24 V AC B0 B0 B0 B0 B0
42 V AC D0 D0 D0 D0 --
48 V AC H0 -- -- H0 --
110 V AC F0 F0 F0 F0 F0
230 V AC P0 P0 P0 P0 P0
240 V AC -- -- U0 U0 --
400 V AC V0 V0 V0 V0 --
Solenoid coils for 50 and 60 Hz2)
24 V AC B0 C2 C2 C2 C2
42 V AC D0 D2 D2 D2 --
48 V AC H0 H2 H2 H2 --
110 V AC F0 G2 G2 G2 --
220 V AC N2 N2 N2 N2 N2
230 V AC P0 L2 L2 L2 L2
Solenoid coils (for USA and Canada3))
50 Hz 60 Hz
110 V AC 120 V AC K6 K6 K6 K6 --
220 V AC 240 V AC P6 P6 P6 P6 --
Solenoid coils (for Japan)
50/60 Hz4) 60 Hz5)
100 V AC 110 V AC G6 G6 G6 G6 G6
200 V AC 220 V AC N6 N6 N6 N6 N6
400 V AC 440 V AC R6 R6 R6 R6 R6
DC operation1)
12 V DC A4 A4 -- -- --
24 V DC B4 B4 -- -- B4
42 V DC D4 D4 -- -- --
48 V DC W4 W4 -- -- --
60 V DC -- -- -- -- --
110 V DC F4 F4 -- -- F4
125 V DC G4 G4 -- -- --
220 V DC M4 M4 -- -- --
230 V DC P4 -- -- -- --

Examples
AC operation 3RT2325-1AP00 Contactor with screw terminals; with solenoid coil for 50 Hz for rated control supply voltage 230 V AC
3RT2325-1AG20 Contactor with screw terminals; with solenoid coil for 50/60 Hz for rated control supply voltage 110 V AC
DC operation 3RT2526-2BB40 Contactor with spring-loaded terminals; for rated control supply voltage of 24 V DC
3RT2526-2BG40 Contactor with spring-loaded terminals; for rated control supply voltage 125 V DC
1) 4)
For deviating coil voltages and operating ranges of sizes S00 and S0, Coil operating range
a SITOP 24 V DC power supply with wide-range input can be used for the - Size S00:
coil control, see page 15/1 and Catalog KT 10.1. at 50/60 Hz: 0.85 to 1.1 x Us,
2) Coil operating range - Sizes S0 to S3:
- at 50 Hz: 0.8 to 1.1 x Us, at 50 Hz: 08 to 1.1 x Us,
- at 60 Hz: 0.85 to 1.1 x Us. at 60 Hz: 0.85 to 1.1 x Us.
5)
3)
Coil operating range Coil operating range at 60 Hz: 0.8 to 1.1 x Us.
- Size S00:
at 50 Hz: 0.85 to 1.1 x Us,
at 60 Hz: 0.8 to 1.1 x Us,
- Sizes S0 to S3: at 50 Hz and 60 Hz: 0.8 to 1.1 x Us.

Rated control supply Contactor 3RT2.2.-.N Rated control supply Contactor 3RT2.3.-.N 3RT2.4.-.N
voltage type voltage type
Us min to Us max1) Size S0 Us min to Us max1) Size S2 S3
Sizes S0 to S3
AC/DC operation (50/60 Hz AC or DC)
21 ... 28 V AC/DC B3 20 ... 33 V AC/DC B3 B3
95 ... 130 V AC/DC F3 48 ... 80 V AC/DC E3 E3
200 ... 280 V AC/DC P3 83 ... 155 V AC/DC F3 F3
175 ... 280 V AC/DC P3 P3
1)
Coil operating range: 0.8 x Us min to 1.1 x Us max.

4/52 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
SIRIUS 3RT23 to 3RT26, 3RT14 contactors
Rated control supply voltages for 3RT14 contactors,
possible on request (change of the 10th and 11th digits of the article number)
Delivery time on request
Rated control supply Contactor 3RT145.-.A, Rated control supply Contactor 3RT145.-.N, 3RT145.-.P,
voltage type 3RT146.-.A, voltage type 3RT146.-.N, 3RT145.-.S,
3RT147.-.A 3RT147.-.N 3RT146.-.P,
3RT146.-.S,
3RT147.-.P,
3RT147.-.S
Us min to Us max Sizes S6 to S12 Us min to Us max Sizes S6 to S12
Sizes S6 to S12
AC/DC operation (50/60 Hz AC or DC) and operating range 0.8 x Us min to 1.1 x Us max
Standard operating mechanism Solid-state operating mechanism

4
23 ... 26 V AC/DC B3 21 ... 27.3 V AC/DC B3 --
42 ... 48 V AC/DC D3 96 ... 127 V AC/DC F3 F3
110 ... 127 V AC/DC F3 200 ... 277 V AC/DC P3 P3
200 ... 220 V AC/DC M3
220 ... 240 V AC/DC P3
240 ... 277 V AC/DC U3
380 ... 420 V AC/DC V3
440 ... 480 V AC/DC R3
500 ... 550 V AC/DC S3
575 ... 600 V AC/DC T3

Siemens IC 10 · 2023 4/53


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
SIRIUS 3RT contactors with extended operating range, 3-pole

■ Overview
Standards Performance range
IEC 60947-4-1, IEC 60077-2, EN 50155 Sizes S00 to S3
• 3RT20 contactors for motor loads (AC-3 and AC-3e)
up to 110 A/55 kW
Sizes S6 to S12
• 3RT10 contactors for motor loads (AC-3 and AC-3e)
from 55 kW to 500 A/250 kW
• 3RT14 contactors for weak or non-inductive loads (AC-1)
up to 690 A

■ Application
4

Besides standard approval in compliance with IEC 60947-4-1, Short-circuit and overload protection of auxiliary connections
the contactors with an extended operating range are also
approved in compliance with the relevant parts of IEC 60077-2, For information on the protection of auxiliary contacts, see the
thus fulfilling the requirement for use in railway applications. technical product data sheet.

Thus, their suitability for increased requirements such as an Short-circuit and overload protection of control supply voltage
connections or supply voltage connections
• extended temperature range compared to the IEC 60947-4-1
product standard or First of all, the relevant standards and regulations for configuring
control panels and the parts and components installed in them
• extended operating range of the contactor operating must be taken into account, for example for cable dimensioning.
mechanisms or also
• increased resistance to mechanical oscillations and vibrations One possible protection for these circuits could be the selection
is warranted. The design of the terminals in the spring-loaded of a suitable power supply, i.e. one with a current-limiting
connection system also contributes toward vibration function. In the selection of the source and the connecting cable,
resistance. the load characteristics of the contactor must be considered
(short-time inrush current peaks for solid-state operating
Operating range of contactor operating mechanisms mechanisms, switch-on power, holding power).
The contactors with extended operating range and railway If there are further switching elements in the circuit, such as the
approval are available with a solid-state DC operating auxiliary contact system of an overload relay that operates the
mechanism in all sizes from S00 to S12. contactor, the short-circuit protection necessary for this must
also be considered.
This operating mechanism version has an operating range from
0.7 to 1.25 x Us in the temperature range -40 to 70 °C. For further recommendations, e.g. the use of miniature circuit
breakers or circuit breakers for equipment in control circuits, see
As from size S6, the operating mechanisms are equipped with Control panel tip – Selecting and dimensioning suitable power
an additional control input that can be operated between 24 DC supplies quickly and reliably.
and 110 V. This function can optionally be switched on or off via
a selector switch. Short-circuit and overload protection of contactors with
a digital input
Protecting connections against short circuit, overload and
overvoltage A typical rated current of 20 mA applies to these inputs based
on the PLC input types according to IEC 60947-4-1.
All connections must generally be protected against overload
and short circuits using suitable measures. Different constraints The inputs can be protected accordingly (for 3RT1...-.X contactors,
must be considered depending on the type of connection: marked with IN+/IN-). The supply voltage connections A1 - A2 must
be protected based on the load characteristics.
Short-circuit and overload protection of main connections
For information on power consumption, see the technical
For information on the protection of a free-standing contactor, product data sheet.
see the technical product data sheet.
Protection against overvoltage at the control supply voltage
For more information on complete units such as contactors with connection
overload relays or contactors with motor starter protectors as the
motor feeder, see Configuration Manual for load feeders. 3RT contactors are already equipped with coil damping
(varistor).
Note:
The break times of the contactor, the opening delay times of the
NO contacts and the closing delay times of the NC contacts
increase with damping.
For more information about influencing the time response using
damping, see Equipment Manual.

4/54 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
SIRIUS 3RT contactors with extended operating range, 3-pole
Fitting auxiliary contacts and mounting additional auxiliary Side-by-side mounting
switches
Contactors with conventional operating mechanism
Features in the delivery state • Sizes S00 and S0:
• 3RT20 contactors: Side-by-side mounting is permissible at ambient
- 3RT201 contactors: temperatures up to 60 °C. At > 60 to 70 °C, a clearance
An auxiliary contact is integrated in the basic unit. of at least 10 mm shall be provided.
- Contactors 3RT202 to 3RT204:
The basic units contain two integrated auxiliary contacts Contactors with series resistor
(1 NO + 1 NC). • Size S00:
• 3RT10 and 3RT14 contactors: Side-by-side mounting is permissible at ambient
These contactors are supplied with two laterally mounted temperatures up to 70 °C.
auxiliary switches. The fitting of auxiliary switches is possible Contactors with solid-state operating mechanism
on the front and on the side. (version: 3RT....-.....-0LA2)

4
Expansion possibilities • Sizes S00 to S3:
Side-by-side mounting is permissible at ambient
All basic units (with the exception of coupling contactors in size temperatures up to 70 °C.
S00) can be expanded using auxiliary switches; the permissible
configuration must be observed. • Sizes S6 to S12:
Side-by-side mounting is permissible at ambient
Detailed information about the fitting of auxiliary switches for temperatures up to 60 °C. At > 60 to 70 °C, a clearance
3RT20 contactors, see pages 3/81 to 3/86. of at least 10 mm shall be provided.
Ambient temperature
The permissible ambient temperature for operation of the
contactors (across the full operating range of the operating
mechanisms) is -40 to +70 °C.

Siemens IC 10 · 2023 4/55


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
SIRIUS 3RT contactors with extended operating range, 3-pole

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/16177/td https://support.industry.siemens.com/cs/ww/en/ps/16177/man
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16177/faq Guide of use for contactors in safety applications, see
https://support.industry.siemens.com/cs/ww/en/view/109807687

Type 3RT2017 3RT2017- 3RT2018- 3RT202. 3RT202.-


2XB4.- 2XF4.- 2XB4.- 2XF4.- 2XB40- 2XF40-
0LA2 0LA2 0LA2 0LA2 0LA2 0LA2
Size S00 S0
General data
4

Upright mounting position


• Contactors with series resistor Special version (on request)
• Contactors with conventional coil Special version (on request)
Ambient temperature
• During operation °C -40 ... +701) -40 ... +70
• During storage °C -55 ... +80
Control
Solenoid coil operating range DC 0.7 ... 1.25 x Us
Power consumption of the solenoid coils For cold coil and 1.0 x Us
• Contactors with series resistor Closing W 13 --
Closed W 4.0 --
• Contactors with conventional coil Closing W 2.8 -- 4.5 --
Closed W 2.8 -- 4.5 --
• Contactors with solid-state operating Closing W -- 4.0 4.5 4.0 4.5 -- 6.7 13.2
mechanism Closed W -- 0.95 0.75 0.95 0.75 -- 1.4 1.3
Rated data of the main contacts
Load rating with AC
Minimum cross-section in the main circuit
• At maximum AC-1 rated value mm2 4 10
• At maximum Ith rated value mm2 -- 4 -- 10
1)
3RT20..-.K contactors without the article number suffix "-0LA2" are All details and technical specifications not mentioned here are
coupling contactors that are certified for the -25 to +60 °C standard identical to those of the basic units, see page 3/25 onwards.
temperature range. For railway applications, an additional certification
approves these contactors with a minimum clearance of 10 mm for the
extended temperature range from -40 to +70 °C.

Type 3RT2035- 3RT2036- 3RT2037- 3RT2038- 3RT204.-


3XB40- 3XF40- 3XB40- 3XF40- 3XB40- 3XF40- 3XB40- 3XF40- 3XB40- 3XF40-
0LA2 0LA2 0LA2 0LA2 0LA2 0LA2 0LA2 0LA2 0LA2 0LA2
Size S2 S3
General data
Ambient temperature
• During operation °C -40 ... +70
• During storage °C -55 ... +80
Control
Solenoid coil operating range DC 0.7 ... 1.25 x Us
Power consumption of the solenoid coils For cold coil and 1.0 x Us
• Contactors with solid-state operating Closing W 23 76 64
mechanism Closed W 1 1.8 1.0
Rated data of the main contacts
Load rating with AC
Minimum cross-section in the main circuit
• At maximum AC-1 rated value mm2 16 25 35 50
• At maximum Ith rated value mm2 16 25 35 50

All details and technical specifications not mentioned here are


identical to those of the basic units, see page 3/25 onwards.

4/56 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
SIRIUS 3RT contactors with extended operating range, 3-pole

Type 3RT1054- 3RT1055- 3RT1056- 3RT1064- 3RT1065- 3RT1066- 3RT1075- 3RT1076-


.X.46- .X.46- .X.46- .X.46- .X.46- .X.46- .X.46- .X.46-
0LA2 0LA2 0LA2 0LA2 0LA2 0LA2 0LA2 0LA2
Size S6 S10 S12
General data
Ambient temperature
• During operation °C -40 ... +70
• During storage °C -55 ... +80
Control
• Solenoid coil closing for DC W 320 580 800
• Solenoid coil closed for DC W 2.8 3.4 3.6
• Control version of the switch operating mechanism PLC-IN or standard A1 - A2 (can be set)

4
Actuated via A1/A2
• Rated control supply voltage V DC 24, 72 or 110
• Operating range 0.7 ... 1.25
Actuated via PLC input
• Rated voltage V DC 24 ... 110
• Operating range 0.7 ... 1.25
• Consumed current at PLC control input according to mA 2
IEC 60947-1, maximum
Rated data of the main contacts
Load rating with AC
Minimum cross-section in the main circuit
• At maximum AC-1 rated value mm2 70 95 150 185 300 370
• At maximum Ith rated value mm2 70 95 150 185 300 370

All details and technical specifications not mentioned here, see


https://support.industry.siemens.com/cs/ww/en/ps/16177/td.

Type 3RT1456-.X.46-0LA2 3RT1466-.X.46-0LA2 3RT1467-.X.46-0LA2 3RT1476-.X.46-0LA2


Size S6 S10 S12
General data
Ambient temperature
• During operation °C -40 ... +70
• During storage °C -55 ... +80
Control
• Solenoid coil closing for DC 320 580 800
• Solenoid coil closed for DC 2.8 3.4 3.6
• Control version of the switch operating mechanism PLC-IN or standard A1 - A2 (can be set)
Actuated via A1/A2
• Rated control supply voltage V DC 24, 72 or 110
• Operating range 0.7 ... 1.25
Actuated via PLC input
• Rated voltage V DC 24 ... 110
• Operating range 0.7 ... 1.25
• Consumed current at PLC control input according to mA 2
IEC 60947-1, maximum
Rated data of the main contacts
Load rating with AC
Minimum cross-section in the main circuit
• At maximum AC-1 rated value mm2 140 240 300 480
• At maximum Ith rated value mm2 140 240 480

All details and technical specifications not mentioned here, see


https://support.industry.siemens.com/cs/ww/en/ps/16177/td.

Siemens IC 10 · 2023 4/57


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
SIRIUS 3RT contactors with extended operating range, 3-pole IE3 ready IE4 ready IE3/IE4 ready
AC-3e

■ Selection and ordering data


DC operation
4

3RT201.-2K.4. 3RT201.-2K.42-0LA0
Rated data according to IEC 60947-4-1 Auxiliary contacts Rated control Spring-loaded PU PS* PG
AC-3 and AC-3e, supply terminals (UNIT,
tu: 70 °C voltage Us SET, M)
Operational Rating of Ident. No. Version
current Ie three-phase motors Article No. Price
up to at per PU
400 V 230 V 400 V 500 V 690 V
A kW kW kW kW NO NC V DC
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
Coupling contactors with integrated coil circuit
• Suppressor diode integrated at the factory
12 3 5.5 5.5 5.5 101) 1 -- 24 3RT2017-2KB41 1 1 unit 41B
110 3RT2017-2KF41 1 1 unit 41B
12 3 5.5 5.5 5.5 011) -- 1 24 3RT2017-2KB42 1 1 unit 41B
110 3RT2017-2KF42 1 1 unit 41B
• Varistor integrated at the factory
12 3 5.5 5.5 5.5 101) 1 -- 24 3RT2017-2LB41 1 1 unit 41B
110 3RT2017-2LF41 1 1 unit 41B
12 3 5.5 5.5 5.5 011) -- 1 24 3RT2017-2LB42 1 1 unit 41B
110 3RT2017-2LF42 1 1 unit 41B
With plug-on series resistor and integrated coil circuit
• Suppressor diode integrated at the factory
12 3 5.5 5.5 5.5 --2) -- 13) 24 3RT2017-2KB42-0LA0 1 1 unit 41B
110 3RT2017-2KF42-0LA0 1 1 unit 41B
16 4 7.5 10 11 --2) -- 13) 24 3RT2018-2KB42-0LA0 1 1 unit 41B
110 3RT2018-2KF42-0LA0 1 1 unit 41B
• Varistor integrated at the factory
12 3 5.5 5.5 5.5 --2) -- 13) 24 3RT2017-2LB42-0LA0 1 1 unit 41B
110 3RT2017-2LF42-0LA0 1 1 unit 41B
16 4 7.5 10 11 --2) -- 13) 24 3RT2018-2LB42-0LA0 1 1 unit 41B
110 3RT2018-2LF42-0LA0 1 1 unit 41B
1) It is not possible to mount an auxiliary switch. A clearance of 10 mm is Accessories and spare parts, see page 3/69 onwards.
required for side-by-side mounting at ambient temperatures > 60 °C.
2)
One 4-pole auxiliary switch according to EN 50005 can be mounted
from -40 to 70 °C; no clearance required.
3)
NC contact cannot be used because it is used for switching of the series
resistor.

* You can order this quantity or a multiple thereof.


4/58 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors with extended operating range, 3-pole
DC operation

3RT201.-2X.41-0LA2 3RT201.-2X.42-0LA2 3RT202.-2K.40 3RT202.-2X.40-0LA2

4
Rated data according to Auxiliary contacts Rated Spring-loaded PU PS* PG
IEC 60077-2 IEC 60947-4-1 control terminals (UNIT,
supply SET, M)
AC-3 and AC-3e voltage Us
tu: 70 °C tu: 60 °C
Conventional Opera- Rating of three-phase Ident. Version
thermal tional motors No.
current Ith current Ie at Article No. Price
up to up to per PU

690 V 400 V 230 V 400 V 500 V 690 V


A A kW kW kW kW NO NC V DC
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
With integrated coil circuit (varistor integrated in electronics at the factory)
18 12 3 5.5 5.5 5.5 10 1 -- 24 ... 34 3RT2017-2XB41-0LA2 1 1 unit 41B
72 ... 125 3RT2017-2XF41-0LA2 1 1 unit 41B
18 12 3 5.5 5.5 5.5 01 -- 1 24 ... 34 3RT2017-2XB42-0LA2 1 1 unit 41B
72 ... 125 3RT2017-2XF42-0LA2 1 1 unit 41B
18 16 4 7.5 10 11 10 1 -- 24 ... 34 3RT2018-2XB41-0LA2 1 1 unit 41B
72 ... 125 3RT2018-2XF41-0LA2 1 1 unit 41B
18 16 4 7.5 10 11 01 -- 1 24 ... 34 3RT2018-2XB42-0LA2 1 1 unit 41B
72 ... 125 3RT2018-2XF42-0LA2 1 1 unit 41B
Size S0
With integrated coil circuit
• Coupling contactors with varistor integrated at the factory
-- 17 4 7.5 10 11 111) 1 1 24 3RT2025-2KB40 1 1 unit 41B
110 3RT2025-2KF40 1 1 unit 41B
-- 25 5.5 11 11 11 111) 1 1 24 3RT2026-2KB40 1 1 unit 41B
110 3RT2026-2KF40 1 1 unit 41B
-- 32 7.5 15 18.5 18.5 111) 1 1 24 3RT2027-2KB40 1 1 unit 41B
110 3RT2027-2KF40 1 1 unit 41B
• Varistor integrated in electronics at the factory
30 17 4 7.5 10 11 11 1 1 24 3RT2025-2XB40-0LA2 1 1 unit 41B
110 3RT2025-2XF40-0LA2 1 1 unit 41B
30 25 5.5 11 11 11 11 1 1 24 3RT2026-2XB40-0LA2 1 1 unit 41B
110 3RT2026-2XF40-0LA2 1 1 unit 41B
36 32 7.5 15 18.5 18.5 11 1 1 24 3RT2027-2XB40-0LA2 1 1 unit 41B
110 3RT2027-2XF40-0LA2 1 1 unit 41B
38 38 7.5 18.5 18.5 18.5 11 1 1 24 3RT2028-2XB40-0LA2 1 1 unit 41B
110 3RT2028-2XF40-0LA2 1 1 unit 41B
1) It is not possible to mount an auxiliary switch. A clearance of 10 mm is Accessories and spare parts, see page 3/69 onwards.
required for side-by-side mounting at ambient temperatures > 60 °C.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/59
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
SIRIUS 3RT contactors with extended operating range, 3-pole IE3 ready IE4 ready IE3/IE4 ready
AC-3e
DC operation
4

3RT203.-3X.40-0LA2 3RT204.-3X.40-0LA2
Rated data according to Auxiliary contacts Rated Spring-loaded PU PS* PG
IEC 60077-2 IEC 60947-4-1 control terminals (UNIT,
supply for auxiliary and control SET, M)
AC-3 and AC-3e voltage circuits
tu: 70 °C tu: 60 °C Us
Conventional Opera- Rating of three-phase Ident. Version
thermal tional motors No.
current Ith current Ie at Article No. Price
up to up to per PU

690 V 400 V 230 V 400 V 500 V 690 V


A A kW kW kW kW NO NC V DC
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S2
With integrated coil circuit (varistor integrated in electronics at the factory)
50 40 11 18.5 22 22 11 1 1 24 3RT2035-3XB40-0LA2 1 1 unit 41B
110 3RT2035-3XF40-0LA2 1 1 unit 41B
55 50 15 22 30 22 11 1 1 24 3RT2036-3XB40-0LA2 1 1 unit 41B
110 3RT2036-3XF40-0LA2 1 1 unit 41B
60 65 18.5 30 37 37 11 1 1 24 3RT2037-3XB40-0LA2 1 1 unit 41B
110 3RT2037-3XF40-0LA2 1 1 unit 41B
75 80 22 37 37 45 11 1 1 24 3RT2038-3XB40-0LA2 1 1 unit 41B
110 3RT2038-3XF40-0LA2 1 1 unit 41B
For screw fixing and snap-on mounting on TH 35-15 and
TH 75-15 DIN rails
Size S3
With integrated coil circuit (varistor integrated in electronics at the factory)
90 80 22 37 45 55 11 1 1 24 3RT2045-3XB40-0LA2 1 1 unit 41B
110 3RT2045-3XF40-0LA2 1 1 unit 41B
95 95 22 45 55 75 11 1 1 24 3RT2046-3XB40-0LA2 1 1 unit 41B
110 3RT2046-3XF40-0LA2 1 1 unit 41B
95 110 30 55 75 75 11 1 1 24 3RT2047-3XB40-0LA2 1 1 unit 41B
110 3RT2047-3XF40-0LA2 1 1 unit 41B

Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


4/60 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
AC-3e E3 ready IE4 ready IE3/IE4 ready SIRIUS 3RT contactors with extended operating range, 3-pole
DC operation
• Solid-state operating mechanism with 24 to 110 V DC control • Main conductors: Busbar connections;
signal input a connection kit with screws, spring washers and nuts
• For screw fixing is enclosed.
• Auxiliary and control conductors: Spring-loaded terminals

4
3RT105.-2X.46-0LA2 3RT106.-2X.46-0LA2 3RT107.-2X.46-0LA2
Size Rated data according to Auxiliary Rated control Spring-loaded PU PS* PG
IEC 60077-2 IEC 60947-4-1 contacts, supply voltage terminals (UNIT,
lateral Us SET, M)
AC-3 and AC-3e
tu: 70 °C tu: 60 °C
Conventional thermal Operational Version
current Ith current Ie Article No. Price
up to up to per PU
690 V 400 V

A A NO NC V DC
Solid-state operating mechanism
With control signal input 24 ... 110 V DC
e. g. for control by PLC
With integrated coil circuit (varistor integrated in electronics at the factory)
S6 120 115 2 2 24 3RT1054-2XB46-0LA2 1 1 unit 41B
72 3RT1054-2XJ46-0LA2 1 1 unit 41B
110 3RT1054-2XF46-0LA2 1 1 unit 41B
140 150 2 2 24 3RT1055-2XB46-0LA2 1 1 unit 41B
72 3RT1055-2XJ46-0LA2 1 1 unit 41B
110 3RT1055-2XF46-0LA2 1 1 unit 41B
145 185 2 2 24 3RT1056-2XB46-0LA2 1 1 unit 41B
72 3RT1056-2XJ46-0LA2 1 1 unit 41B
110 3RT1056-2XF46-0LA2 1 1 unit 41B
S10 215 225 2 2 24 3RT1064-2XB46-0LA2 1 1 unit 41B
72 3RT1064-2XJ46-0LA2 1 1 unit 41B
110 3RT1064-2XF46-0LA2 1 1 unit 41B
265 265 2 2 24 3RT1065-2XB46-0LA2 1 1 unit 41B
72 3RT1065-2XJ46-0LA2 1 1 unit 41B
110 3RT1065-2XF46-0LA2 1 1 unit 41B
265 300 2 2 24 3RT1066-2XB46-0LA2 1 1 unit 41B
72 3RT1066-2XJ46-0LA2 1 1 unit 41B
110 3RT1066-2XF46-0LA2 1 1 unit 41B
S12 350 400 2 2 24 3RT1075-2XB46-0LA2 1 1 unit 41B
72 3RT1075-2XJ46-0LA2 1 1 unit 41B
110 3RT1075-2XF46-0LA2 1 1 unit 41B
475 500 2 2 24 3RT1076-2XB46-0LA2 1 1 unit 41B
72 3RT1076-2XJ46-0LA2 1 1 unit 41B
110 3RT1076-2XF46-0LA2 1 1 unit 41B

Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/61
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
SIRIUS 3RT contactors with extended operating range, 3-pole
DC operation
• Solid-state operating mechanism with 24 to 110 V DC control • Main conductors: Busbar connections;
signal input a connection kit with screws, spring washers and nuts
• For screw fixing is enclosed.
• Auxiliary and control conductors: Spring-loaded terminals
4

3RT1456-2X.46-0LA2 3RT146.-2X.46-0LA2 3RT1476-2X.46-0LA2


Size Rated data according to Auxiliary Rated control Spring-loaded PU PS* PG
IEC 60077-2 IEC 60947-4-1 contacts, supply voltage terminals (UNIT,
lateral Us SET, M)
AC-1
tu: 70 °C tu: 40 °C
Conventional thermal Operational Version
current Ith current Ie Article No. Price
up to up to per PU
690 V 400 V

A A NO NC V DC
Solid-state operating mechanism
With control signal input 24 ... 110 V DC
e. g. for control by PLC
With integrated coil circuit (varistor integrated in electronics at the factory)
S6 190 275 2 2 24 3RT1456-2XB46-0LA2 1 1 unit 41B
72 3RT1456-2XJ46-0LA2 1 1 unit 41B
110 3RT1456-2XF46-0LA2 1 1 unit 41B
S10 330 400 2 2 24 3RT1466-2XB46-0LA2 1 1 unit 41B
72 3RT1466-2XJ46-0LA2 1 1 unit 41B
110 3RT1466-2XF46-0LA2 1 1 unit 41B
330 500 2 2 24 3RT1467-2XB46-0LA2 1 1 unit 41B
72 3RT1467-2XJ46-0LA2 1 1 unit 41B
110 3RT1467-2XF46-0LA2 1 1 unit 41B
S12 520 690 2 2 24 3RT1476-2XB46-0LA2 1 1 unit 41B
72 3RT1476-2XJ46-0LA2 1 1 unit 41B
110 3RT1476-2XF46-0LA2 1 1 unit 41B

Accessories and spare parts, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


4/62 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
SIRIUS 3RH2 contactor relays with extended operating range

■ Overview
Standards Control and auxiliary circuits
IEC 60947-5-1 The solenoid coils of the contactor relays have an extended coil
operating range from 0.7 to 1.25 x Us and are fitted as standard
Ambient temperature with surge suppressors. The opening delay time is consequently
The permissible ambient temperature for operation of the 2 to 5 ms longer than for standard contactors.
contactor relays (across the full operating range of the operating
mechanisms) is -40 to +70 °C.
Uninterrupted duty at temperatures > +60 °C reduces the
mechanical endurance, the current carrying capacity of the
conducting paths and the switching frequency.

4
■ Application
For operation in installations that are subject both to If there are further switching elements in the circuit, such as the
considerable variations in the control voltage and to high auxiliary contact system of an overload relay that operates the
ambient temperatures, e. g. railway applications under extreme auxiliary contactor, the short-circuit protection necessary for this
climatic conditions, rolling mills, etc. must also be considered.
Also for control supply voltages with battery buffering to extend For further recommendations, e.g. the use of miniature circuit
the operating time in the event of battery charge failure. breakers or circuit breakers for equipment in control circuits, see
Control panel tip – Selecting and dimensioning suitable power
Operating mechanism types supplies quickly and reliably.
Contactor relays with conventional coil Protection against overvoltage at the control supply voltage
These auxiliary contactors have an extended operating range of connection
0.7 to 1.25 x Us. An additional auxiliary switch is not required. • Contactor relays with conventional coil:
Contactor relays with series resistor A surge suppressor (suppressor diode) is integrated.
• Contactor relays with series resistor:
These auxiliary contactors have an extended operating range of A surge suppressor (a suppressor diode or varistor as
0.7 to 1.25 x Us. preferred) is integrated.
The DC solenoid system is modified to holding operation by • Contactor relays with solid-state operating mechanism:
means of a series resistor. This is plugged on in a prewired A surge suppressor (varistor) is integrated.
module.
Connection methods
A 4-pole auxiliary switch can be fitted additionally.
The 3RH2 contactor relays are available with screw terminals.
Contactor relays with solid-state operating mechanism
Side-by-side mounting
Thanks to the integrated electronics, these auxiliary contactors
have an extended operating range of 0.7 to 1.25 x Us. Contactor relays with conventional coil
Protecting connections against short circuit, overload and A clearance of 10 mm is required for side-by-side mounting at
overvoltage ambient temperatures > 60 °C  70 °C.
All connections must generally be protected against overload Contactor relays with series resistor
and short circuits using suitable measures. Different constraints Side-by-side mounting is permissible at ambient temperatures
must be considered depending on the type of connection: up to 70 °C.
Short-circuit and overload protection of auxiliary connections Contactor relays with solid-state operating mechanism
For information on the protection of auxiliary contacts, see the Side-by-side mounting is permissible at ambient temperatures
technical product data sheet. up to 70 °C.
Short-circuit and overload protection of control supply voltage
connections or supply voltage connections
First of all, the relevant standards and regulations for configuring
control panels and the parts and components installed in them
must be taken into account, for example for cable dimensioning.
One possible protection for these circuits could be the selection
of a suitable power supply, i.e. one with a current-limiting
function. In the selection of the source and the connecting cable,
the load characteristics of the contactor relay must be
considered (short-time inrush current peaks for solid-state
operating mechanisms, switch-on power, holding power).

Siemens IC 10 · 2023 4/63


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
SIRIUS 3RH2 contactor relays with extended operating range

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/16174/td https://support.industry.siemens.com/cs/ww/en/ps/16174/man
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16174/faq

Contactor relays Type 3RH21..-2K, -2L 3RH2122-2XB40-0LA2 3RH2122-2XF40-0LA2


General data
Upright mounting position
• Contactors with series resistor Special version (on request)
• Contactors with conventional coil Special version (on request)
4

Ambient temperature
• During operation °C -40 ... +701)
• During storage °C -55 ... +80
Control
Solenoid coil operating range DC operation 0.7 ... 1.25 x Us
Power consumption of the solenoid coils For cold coil and 1.0 x Us
• Contactors with series resistor Closing W 13 -- --
Closed W 4 -- --
• Contactors with conventional coil Closing W 2.8 -- --
Closed W 2.8 -- --
• Contactors with solid-state operating Closing W -- 4 4.5
mechanism Closed W -- 0.95 0.75
1) 3RH21..-.K contactor relays without article number suffix "-0LA." are
coupling contactor relays that are certified for the temperature range -25 to
+60 °C. For railway applications, an additional certification approves these
contactors with a minimum clearance of 10 mm for the extended
temperature range from -40 to +70 °C.
All details and technical specifications not mentioned here are
identical to those of the 3RH2 basic units, see page 5/5 onwards.

4/64 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
SIRIUS 3RH2 contactor relays with extended operating range

■ Selection and ordering data


DC operation

3RH2122-2K.40 3RH2122-2K.40-0LA0

4
Rated operational current Contacts Rated control Spring-loaded PU PS* PG
Ie/AC-15/AC-14 Ident. No. Version supply voltage terminals (UNIT,
tu: 70 °C at according Us SET, M)
to
230 V 400 V 500 V 690 V EN 50011
Article No. Price
per PU

A A A A NO NC V DC
For screw fixing and snap-on mounting on TH 35 DIN rail
Size S00
With integrated coil circuit
• Suppressor diode integrated at the factory
10 3 2 1 22E 2 21) 24 3RH2122-2KB40 1 1 unit 41A
110 3RH2122-2KF40 1 1 unit 41A
31E 3 11) 24 3RH2131-2KB40 1 1 unit 41A
40E 4 01) 24 3RH2140-2KB40 1 1 unit 41A
• Varistor integrated at the factory
10 3 2 1 22E 2 21) 24 3RH2122-2LB40 1 1 unit 41A
110 3RH2122-2LF40 1 1 unit 41A
With plug-on series resistor and integrated coil circuit
• Suppressor diode integrated at the factory
10 3 2 1 21X 2 12) 24 3RH2122-2KB40-0LA0 1 1 unit 41A
110 3RH2122-2KF40-0LA0 1 1 unit 41A
• Varistor integrated at the factory
10 3 2 1 21X 2 12) 24 3RH2122-2LB40-0LA0 1 1 unit 41A
110 3RH2122-2LF40-0LA0 1 1 unit 41A
With integrated coil circuit (varistor integrated in electronics at the factory)
10 3 2 1 22E 2 22) 24 ... 34 3RH2122-2XB40-0LA2 1 1 unit 41A
72 ... 125 3RH2122-2XF40-0LA2 1 1 unit 41A
1) It is not possible to mount an auxiliary switch. Accessories, see page 3/69 onwards.
2)
4-pole auxiliary switch according to EN 50005 can be mounted.
Other voltages according to page 3/67 on request.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/65
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
3TH4 contactor relays, 8-pole

■ Overview
Standards Ambient temperature
IEC 60947-5-1 The permissible ambient temperature for operation of the
contactors (across the full solenoid coil operating range)
Terminal covers may have to be fitted onto the connecting bars, is -50 to +70 °C. Uninterrupted duty at temperatures < -25 °C
depending on the configuration with other devices. and > +55 °C reduces the mechanical endurance, the current
carrying capacity of the conducting paths and the switching
frequency.
A clearance of 10 mm is required for side-by-side mounting at
ambient temperatures > 55 °C. There is no need to reduce the
technical specifications.
4

■ Application
For operation in installations which are subject both to Control and auxiliary circuits
considerable variations in the control voltage and to high
ambient temperatures, e.g. in railway applications. The solenoid coils of the contactor relays have an extended coil
operating range from 0.7 to 1.25 x Us and are fitted as standard
with varistors to provide protection against overvoltage. The
opening delay time is consequently 2 to 5 ms longer than for
standard contactors.

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/16176/td https://support.industry.siemens.com/cs/ww/en/ps/16176/man
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16176/faq

Contactor relays Type 3TH42


General data
Permissible ambient temperature
• During operation °C -50 ... +701)
• During storage °C -55 ... +80
Control
Solenoid coil operating range 0.7 ... 1.25 x Us
Power consumption of the solenoid coils (for cold coil and 1.0 x Us) W 5.2
For cold coil: Closing = Closed
Permissible residual current of the electronics (with 0 signal)
• DC operation  10 mA x (24 V/Us)
Operating times within operating range
Total break time = Opening delay time + Arcing time
• DC operation Closing delay ms 40 ... 200
Opening delay time ms 20 ... 30
• Arcing time ms 10 ... 20
1)
Side-by-side mounting with 10 mm clearance. All details and technical specifications not mentioned here are
identical to those of the 3TH4 basic units, see page 5/14
onwards.

4/66 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
3TH4 contactor relays, 8-pole

■ Selection and ordering data


DC operation

3TH4244-0L..

4
Contacts Rated operational current Contacts1) Rated control Screw terminals PU PS* PG
Ie/AC-15/AC-14 Ident. No. Version supply voltage (UNIT,
according Us SET, M)
to
230 V 400 V 500 V 690 V EN 50011
Article No. Price
per PU

Number A A A A NO NC V DC
For screw fixing and snap-on mounting on TH 35 DIN rail
With integrated coil circuit (varistor integrated at the factory)
8 10 6 4 2 44E 4 4 24 3TH4244-0LB4 1 1 unit 41A
110 3TH4244-0LF4 1 1 unit 41A
8 10 6 4 2 53E 5 3 24 3TH4253-0LB4 1 1 unit 41A
110 3TH4253-0LF4 1 1 unit 41A
8 10 6 4 2 62E 6 2 24 3TH4262-0LB4 1 1 unit 41A
110 3TH4262-0LF4 1 1 unit 41A
1)
No expansion contacts can be fitted. Other voltages according to page 5/19 on request.
Accessories, see page 5/20.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/67
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
3TC contactors for switching DC voltage, 2-pole

■ Overview
Standards Protection against overvoltage at the control supply voltage
connection
IEC 60947-4-1
The 3TC contactors for railway applications are fitted as
Protecting connections against short circuit, overload and standard with varistors against overvoltage.
overvoltage
Ambient temperature
All connections must generally be protected against overload
and short circuits using suitable measures. Different constraints The permissible ambient temperature for operation of the
must be considered depending on the type of connection: contactors (across the full solenoid coil operating range)
is -50 to +70 °C. Uninterrupted duty at temperatures < -25 °C and
Short-circuit and overload protection of main connections > +55 °C reduces the mechanical endurance, the current
For information on the protection of a free-standing contactor, carrying capacity of the conducting paths and the switching
4

see the technical product data sheet. frequency.


For more information on complete units such as contactors with A clearance of 10 mm is required for side-by-side mounting of
overload relays or contactors with motor starter protectors as the size 2 contactors at ambient temperatures > 55 °C. There is no
motor feeder, see Configuration Manual for load feeders. need to reduce the technical specifications.
Short-circuit and overload protection of auxiliary connections Series resistor
For information on the protection of auxiliary contacts, see the The DC solenoid systems of the 3TC contactors must be modified
technical product data sheet. (to holding coil) by means of a series resistor. This series resistor
is supplied separately packed with the contactors.
Short-circuit and overload protection of control supply voltage
connections or supply voltage connections With types 3TC48, the series resistor must be attached onto the
right-hand side of the auxiliary switch by means of the enclosed
First of all, the relevant standards and regulations for configuring mounting parts and sets of links provided, while in the case of
control panels and the parts and components installed in them the 3TC44 it must be mounted and wired between the contactor
must be taken into account, for example for cable dimensioning. poles. With types 3TC52 and 3TC56, the series resistor must be
One possible protection for these circuits could be the selection attached separately next to the contactors.
of a suitable power supply, i.e. one with a current-limiting
function. In the selection of the source and the connecting cable, Fitting auxiliary contacts and mounting additional auxiliary
the load characteristics of the contactor must be considered switches
(short-time inrush current peaks for solid-state operating Features in the delivery state
mechanisms, switch-on power, holding power).
The 3TC contactors are equipped with two lateral auxiliary
If there are further switching elements in the circuit, such as the switches with four auxiliary contacts. Of those contacts, one NC
auxiliary contact system of an overload relay that operates the contact is required if a series resistor is used (2 NO + 1 NC).
contactor, the short-circuit protection necessary for this must
also be considered. Expansion possibilities

For further recommendations, e.g. the use of miniature circuit Contactors with AC operation can be expanded using auxiliary
breakers or circuit breakers for equipment in control circuits, see switches; the permissible configuration must be observed.
Control panel tip – Selecting and dimensioning suitable power Reversing contactors
supplies quickly and reliably.
With the 3TC52 and 3TC56 contactors, the series resistor must
be connected using an additional K2 reversing contactor.
This contactor is automatically included in the scope of supply.

■ Application
For operation in installations which are subject both to Control and auxiliary circuits
considerable variations in the control voltage and to high
ambient temperatures, e.g. in railway applications. The solenoid coils of the contactors have an extended coil
operating range from 0.7 to 1.25 x Us.

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/16180/td https://support.industry.siemens.com/cs/ww/en/ps/16180/man

Type 3TC44 3TC48 3TC52 3TC56


Size 2 4 8 12
General data
Ambient temperature
• During operation °C -40 ... +70
Control
Solenoid coil operating range 0.7 ... 1.25 x Us
Power consumption of the solenoid coils For cold coil and 1.0 x Us
• Closing W 48 26 40 130
• Closed W 13 14 21 59

All details and technical specifications not mentioned here see page 4/71.
are identical to those of the basic units of the 3TC contactors,

4/68 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
Contactors for railway applications
3TC contactors for switching DC voltage, 2-pole

■ Selection and ordering data


DC operation
3TC44: For screw fixing and snap-on mounting on 35 mm DIN rail
3TC48 to 3TC56: For screw fixing

4
3TC48 3TC56 with reversing contactor
Size Utilization Rated Rated power Auxiliary Rated control Screw terminals PU PS* PG
category operational of loads contacts1) supply (UNIT,
current Ie at voltage Us SET, M)
at Version
Article No. Price
per PU
750 V 220 V 440 V 600 V 750 V
A kW kW kW kW NO NC V DC
Contactors for switching DC voltage
With integrated coil circuit (varistor integrated at the factory)
2 DC-1 32 7 14 19.2 24 2 12) 24 3TC4417-0LB4 1 1 unit 41B
DC-3/DC-5 7.5 5 9 9 4 110 3TC4417-0LF4 1 1 unit 41B
With laterally mounted coil circuit (varistor mounted externally in
additional auxiliary switch enclosure on the contactor)
4 DC-1 75 16.5 33 45 56 2 12) 24 3TC4817-0LB4 1 1 unit 41B
DC-3/DC-5 75 13 27 38 45 110 3TC4817-0LF4 1 1 unit 41B
8 DC-1 170 48 97 132 165 2 12) 24 3TC5217-0LB4 1 1 unit 41B
DC-3/DC-5 170 41 82 110 110 110 3TC5217-0LF4 1 1 unit 41B
12 DC-1 400 88 176 240 300 2 12) 24 3TC5617-0LB4 1 1 unit 41B
DC-3/DC-5 400 70 140 200 250 110 3TC5617-0LF4 1 1 unit 41B
1) No expansion auxiliary contacts can be fitted. Other rated control supply voltages according to page 4/78
2)
One NC contact used for series resistor. on request.

■ Accessories
Accessories, see basic units of the 3TC contactors, page 4/78
onwards.
Spare parts for contactors with extended operating range
For contactors Remarks Rated control Article No. Price PU PS* PG
supply voltage per PU (UNIT,
Us SET, M)
Size Type V DC
Arc chutes
2 3TC4417-0L.. With recess for resistor -- 3TY2442-0B 1 1 unit 41B
mounting
Solenoid coils
2 3TC44 With series resistor, 24 3TY6443-0LB4 1 1 unit 41B
without varistor 110 3TY6443-0LF4 1 1 unit 41B
4 3TC48 24 3TY6483-0LB4 1 1 unit 41B
110 3TY6483-0LF4 1 1 unit 41B

All spare parts not mentioned here are identical to those of


the basic units of the 3TC contactors, see page 4/78.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/69
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
3TC contactors for switching DC voltage, 1- and 2-pole

■ Overview
3TC4 and 3TC5 3TC7
IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1 (auxiliary switches) IEC 60947-4-1
The DC motor ratings given in the tables are applicable to the The contactors are suitable for switching and controlling
DC-3 and DC-5 utilization categories with 2-pole switching of the DC motors as well as all other DC loads.
load or with the two conducting paths of the contactor
connected in series. The solenoid excitation is configured for a particularly large
operating range. It is between 0.7 or 0.8 and 1.2  Us.
One contactor conducting path can switch full power up to
220 V. For voltages over 220 V, the two conducting paths are to 3TC74 contactors can be used at up to 750 V/400 A and 50 Hz
be switched in series, see Rated data of the main contacts, in AC-1 operation. For voltages over 750 V, the two conducting
page 4/73. paths (3TC74: two contactors) are to be switched in series,
see Rated data of the main contacts, page 4/75.
4

Surge suppression
Contactors (not for railway applications) supplied without a coil
circuit can be retrofitted with RC elements, varistors, diodes or
diode assemblies (combination of diode and Zener diode for
short break times) for damping switching overvoltages in the
coil, see page 4/79 onwards.
Fitting auxiliary contacts and mounting additional auxiliary
switches
• Features in the delivery state:
The 3TC contactors are equipped with two lateral auxiliary
switches with four auxiliary contacts. Of those contacts,
one NC contact is required if a series resistor is used
(2 NO + 1 NC).
• Expansion possibilities:
Contactors with AC operation can be expanded using
auxiliary switches; the permissible configuration must be
observed.

■ Application
The contactors are suitable for switching and controlling A version with a particularly large solenoid coil operating range
DC motors as well as all other DC circuits. is available for operation in electrically driven vehicles and in
switchgear subject to large fluctuations in actuating voltage
(see page 4/69).

4/70 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
3TC contactors for switching DC voltage, 1- and 2-pole

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/16181/td https://support.industry.siemens.com/cs/ww/en/ps/16181/man
FAQs, see
https://support.industry.siemens.com/cs/ww/en/ps/16181/faq

Type 3TC4 and 3TC7 3TC5


Rated data of the auxiliary contacts
Rated insulation voltage Ui (pollution degree 3) V 690
Conventional thermal current Ith = A 10 10
rated operational current Ie/AC-12

4
AC load
Rated operational current Ie/AC-15/AC-14
• At rated operational voltage Ue 24 V A 10 10
110 V A 10 10
125 V A 10 10
220 V A 6 6
230 V A 5.6 5.6
380 V A 4 4
400 V A 3.6 3.6
500 V A 2.5 2.5
660 V A 2.5 2.5
690 V A -- --
DC load
Rated operational current Ie/DC-12
• At rated operational voltage Ue 24 V A 10 10
60 V A 10 10
110 V A 3.2 8
125 V A 2.5 6
220 V A 0.9 2
440 V A 0.33 0.6
600 V A 0.22 0.4
Rated operational current Ie/DC-13
• At rated operational voltage Ue 24 V A 10 10
48 V A 5 5
110 V A 1.14 2.4
125 V A 0.98 2.1
220 V A 0.48 1.1
440 V A 0.13 0.32
600 V A 0.07 0.21

Type 3TC44 to 3TC56


s and u rated data of the auxiliary contacts
Rated voltage, max. V AC 600
Switching capacity A 600, P 600

Siemens IC 10 · 2023 4/71


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
3TC contactors for switching DC voltage, 1- and 2-pole

Type 3TC44 to 3TC78


Contact endurance of the main contacts
10 7 20
8 NSB0_00655 NSB0_00656
6 Mill.
4

Operating cycles at 500 V


Operating cycles at 500 V

18
3TC44 3TC48 3TC52 3TC56
2
16
10 6
8
6 14
4

2 12

5
10 10
4

8
6
4 8
2
6
10 4
8
6 4
4
2
2
0,5
10 3
200 400 50 100 150 200 250 300 a (A) 400
10 20 40 100 600 1 000 a (A)

3TC44 to 3TC56 contactors 3TC74 and 3TC78 contactors


Legend for the diagrams:
Ia = Breaking current

Contactor Type 3TC44 3TC48 3TC52 3TC56


Size 2 4 8 12
General data
Dimensions (W x H x D)
• DC operation mm 70 x 85 x 141 100 x 183 x 180 135 x 238 x 232 160 x 279 x 310
H

• AC operation mm 70 x 85 x 100 100 x 183 x 154 135 x 238 x 200 160 x 279 x 251
D

Permissible mounting position


NSB0_00650c

22,5° 22,5° 22,5° 22,5°


The contactors are designed for operation on a vertical mounting surface.

Mechanical endurance Operating cycles 10 million


Electrical endurance See the endurance diagram above
Rated insulation voltage Ui (pollution degree 3) V 800 1 000
Rated impulse withstand voltage Uimp kV 8
Protective separation between the coil and the main contacts V Up to 300 Up to 660
according to IEC 60947-1, Annex N
Mirror contacts1) Yes, according to IEC 60947-4-1, Annex F
A mirror contact is an auxiliary NC contact that cannot be closed
simultaneously with an NO main contact.
Permissible ambient temperature
• During operation °C -25 ... +55
• During storage °C -50 ... +80
Short-circuit protection
Main circuit
• Type of coordination "1" 2 x 3NA3020 2 x 3NA31.. 3NE1332-4D 2 x 3NE1330-4D
(50 A) in series (160 A) in series (400 A) (315 A) parallel
• Type of coordination "2" 2 x 3NA3020 2 x 3NA31.. 3NE1332-4D 2 x 3NE1330-4D
(50 A) in series (63 A) in series (400 A) (315 A) parallel
Auxiliary circuit
(short-circuit current Ik  1 kA)
• Fuse links, operational class gG: A 16
DIAZED, type 5SB; NEOZED, type 5SE
• Miniature circuit breaker with C characteristic A 10
1)
For 3TC44, one NC contact each must be connected in series for the right Rated data of the auxiliary contacts, see page 4/71.
and left auxiliary switch respectively.

4/72 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
3TC contactors for switching DC voltage, 1- and 2-pole

Type 3TC44 3TC48 3TC52 3TC56


Size 2 4 8 12
Control
Solenoid coil operating range
• DC operation 0.7 ... 1.25 x Us
• AC operation 0.8 ... 1.1 x Us
Power consumption of the solenoid coils
(for cold coil and 1.0 x Us)
• DC operation Closing = W 10 19 30 86
Closed
• AC operation, 50 Hz coil Closing VA/p.f.  68/0.86 300/0.5 640/0.48 1 780/0.3
Closed VA/p.f.  10/0.29 26/0.24 46/0.23 121/0.22
VA/p.f. 

4
• AC operation, 60 Hz coil Closing 95/0.79 365/0.45 730/0.38 2 140/0.3
Closed VA/p.f.  12/0.3 35/0.26 56/0.24 140/0.29
• AC operation, 50/60 Hz coil Closing VA/p.f.  79/73/0.83/0.78 --
at 50/60 Hz
Closed VA/p.f.  11/9/0.28/0.27 --
at 50/60 Hz
Rated data of the main contacts
Load rating with DC
Utilization category DC-1 (L/R  1 ms)
• Rated operational currents Ie Up to Ue 750 V A 32 75 220 400
(at 55 °C)
• Minimum conductor cross-section mm2 6 25 95 240
• Rated power at Ue At 220 V kW 7 16.5 48 88
( 220 V DC: one conducting path, 440 V kW 14 33 97 176
> 220 V DC: two conducting paths in series) 600 V kW 19.2 45 132 240
750 V kW 24 56 165 300
Utilization category DC-3 and DC-5,
shunt-wound and series-wound motors (L/R  15 ms)
• Rated operational currents Ie Up to 220 V A 32 75 220 400
(at 55 °C) 440 V A 29 75 220 400
600 V A 21 75 220 400
750 V A 7.5 75 170 400
• Rated power at Ue At 110 V kW 2.5 6.5 20 35
( 220 V DC: one conducting path, 220 V kW 5 13 41 70
> 220 V DC: two conducting paths in series) 440 V kW 9 27 82 140
600 V kW 9 38 110 200
750 V kW 4 45 110 250
Conductor cross-sections
Main conductors Screw terminals
(1 or 2 conductors can be connected)
• Solid mm2 2 x (2.5 ... 10) 2 x (6 ... 16) --
• Finely stranded with end sleeve mm2 2 x (1.5 ... 4) --
• Stranded with cable lug mm2 2 x 16 2 x 35 2 x 120 2 x 150
• Pin cable lug according to DIN 46231 mm2 2 x (1 ... 6) --
• Busbars mm -- 15 x 2.5 25 x 4 2 x (25 x 3)
• Terminal screw M5 M6 M10
Auxiliary conductors
(1 or 2 conductors can be connected)
• Solid mm2 2 x (1 ... 2.5)
• Finely stranded with end sleeve mm2 2 x (0.75 ... 1.5)

Rated data of the auxiliary contacts, see page 4/71.

Siemens IC 10 · 2023 4/73


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
3TC contactors for switching DC voltage, 1- and 2-pole

Type 3TC74 3TC78


Design 1-pole contactors 2-pole contactors
General data
Dimensions (W x H x D) mm 78 x 352 x 276 160 x 366 x 290

D
W

Permissible mounting position

NSB0_00650c
22,5° 22,5° 22,5° 22,5°
The contactors are designed for operation on a vertical
mounting surface.
4

Mechanical endurance Oper- 30 million


ating
cycles
Electrical endurance See page 4/72
Rated insulation voltage Ui (pollution degree 3) V 1 500
Rated impulse withstand voltage Uimp kV 8
Protective separation between the coil and the main contacts V 630
according to IEC 60947-1, Annex N
Mirror contacts1) Yes, according to IEC 60947-4-1, Annex F
A mirror contact is an auxiliary NC contact that cannot
be closed simultaneously with an NO main contact.
Permissible ambient temperature °C -25 ... +55
Short-circuit protection
Main circuit
• Type of coordination "1" A 2 x 3NE1330-4D (315 A) parallel 2 x 3NE1330-5E (315 A) parallel
• Type of coordination "2" A 2 x 3NE1330-4D (315 A) parallel 2 x 3NE1330-5E (315 A) parallel
Auxiliary circuit
(short-circuit current Ik  1 kA)
• Fuse links, operational class gG: A 16
DIAZED, type 5SB; NEOZED, type 5SE
• Miniature circuit breaker with C characteristic A 10
Control
Solenoid coil operating range
• DC operation At Uc = 24 V 0.8 ... 1.2 x Us
At Uc > 24 V 0.7 ... 1.2 x Us
• AC operation At Uc = 24 V 0.7 ... 1.15 x Us
At Uc > 24 V 0.7 ... 1.14 x Us
Power consumption of the solenoid coils
(for cold coil and 1.0 x Us)
• DC operation Closing W 46 92
= Closed
• AC operation, 50 Hz Closing VA 80 160
= Closed
P.f.  0.95
1) For 3TC78, one auxiliary NC contact each of the right and left conducting Rated data of the auxiliary contacts, see page 4/71.
paths must be connected in series.

4/74 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
3TC contactors for switching DC voltage, 1- and 2-pole

Type 3TC74 3TC78


Design 1-pole contactors 2-pole contactors
Rated data of the main contacts
Load rating with DC
Utilization category DC-1 (L/R  1 ms)
• Rated operational current Ie/DC-1 (at 55 °C) A 500
• Minimum conductor cross-section mm2 2 x 150
• Rated power At 220 V kW 110
( 750 V DC: one conducting path, 440 V kW 220
> 750 V DC: two conducting paths in series) 600 V kW 300
750 V kW 375
1 200 V kW -- 600
1 500 V kW -- 750

4
• Critical currents, without arc extinction At 440 V A 7 --
600 V A  13 --
750 V A  15 --
800 V A -- 7
1 200 V A --  13
1 500 V A --  15
Utilization category DC-3 and DC-5,
shunt-wound and series-wound motors (L/R  15 ms)
• Rated operational current Ie (at 55 °C) A 400
• Rated power at Ue At 110 V kW 35
( 750 V DC: one conducting path, 220 V kW 70
> 750 V DC: two conducting paths in series) 440 V kW 140
600 V kW 200
750 V kW 250
1 200 V kW -- 400
1 500 V kW -- 500
Permissible rated current for regenerative braking A 400
At 110 ... 600 V
Conductor cross-sections
Main conductors Screw terminals
(1 or 2 conductors can be connected)
• Stranded with cable lug mm2 2 x ... 150
• Busbars mm 2 x (30 x 4)
Auxiliary conductors
(1 or 2 conductors can be connected)
• Solid mm2 1 ... 2.5
• Finely stranded with end sleeve mm2 0.75 ... 1.5

Rated data of the auxiliary contacts, see page 4/71.

Siemens IC 10 · 2023 4/75


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
3TC contactors for switching DC voltage, 1- and 2-pole

■ Selection and ordering data


DC operation or AC operation, 50 Hz

3TC44 3TC48
4

Size Utilization Opera- Ratings of Auxiliary Rated control Screw terminals PU PS* PG
category1) tional DC motors contacts3) supply voltage (UNIT,
current at Version Us SET, M)
Ie2)
110 V 220 V 440 V 600 V 750 V Article No. Price
per PU

A kW kW kW kW kW NO NC V
3TC44 to 3TC56 2-pole contactors · Operational voltage up to 750 V
DC operation
For screw fixing and snap-on mounting on TH 35 DIN rail
2 DC-3, 32 2.5 5 9 9 4 2 2 24 DC 3TC4417-0AB4 1 1 unit 41B
DC-5 110 DC 3TC4417-0AF4 1 1 unit 41B
220 DC 3TC4417-0AM4 1 1 unit 41B
For screw fixing
4 DC-3, 75 6.5 13 27 38 45 2 2 24 DC 3TC4817-0AB4 1 1 unit 41B
DC-5 110 DC 3TC4817-0AF4 1 1 unit 41B
220 DC 3TC4817-0AM4 1 1 unit 41B
8 DC-3, 2204) 20 41 82 110 110 2 2 24 DC 3TC5217-0AB4 1 1 unit 41B
DC-5 110 DC 3TC5217-0AF4 1 1 unit 41B
220 DC 3TC5217-0AM4 1 1 unit 41B
12 DC-3, 400 35 70 140 200 250 2 2 24 DC 3TC5617-0AB4 1 1 unit 41B
DC-5 110 DC 3TC5617-0AF4 1 1 unit 41B
220 DC 3TC5617-0AM4 1 1 unit 41B
AC operation, 50 Hz
For screw fixing and snap-on mounting on TH 35 DIN rail
2 DC-3, 32 2.5 5 9 9 4 2 2 220/230 AC5) 3TC4417-0BP0 1 1 unit 41B
DC-5 110/110 AC 3TC4417-0BF0 1 1 unit 41B
For screw fixing
4 DC-3, 75 6.5 13 27 38 45 2 2 220/230 AC5) 3TC4817-0BP0 1 1 unit 41B
DC-5 110 AC 3TC4817-0BF0 1 1 unit 41B
8 DC-3, 2204) 20 41 82 110 110 2 2 220/230 AC5) 3TC5217-0BP0 1 1 unit 41B
DC-5 110 AC 3TC5217-0BF0 1 1 unit 41B
12 DC-3, 400 35 70 140 200 250 2 2 220/230 AC5) 3TC5617-0BP0 1 1 unit 41B
DC-5 110 AC 3TC5617-0BF0 1 1 unit 41B
1)
Permissible load for DC-1 utilization category, see detailed technical Other rated control supply voltages according to page 4/78
specifications in the Reference Manual. on request.
2)
The following rated operational currents are permitted for reversing duty
with 3TC44 to 3TC56 contactors: Accessories, see page 4/78 onwards.
Contactor Rated operational voltage Spare parts, see page 4/80.
Type 110 V, 220 V 440 V
3TC44 32 A 7A
3TC48 75 A 75 A
3TC52 170 A 170 A
3TC56 400 A 400 A
3) The fitting of auxiliary switches cannot be altered on DC-operated
contactors.
4)
At > 600 V: Ie = 170 A.
5)
Operating range at 220 V AC: 0.85 to 1.15 × Us;
lower operating range limit according to IEC 60947.

* You can order this quantity or a multiple thereof.


4/76 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
3TC contactors for switching DC voltage, 1- and 2-pole
DC operation or AC operation, 50 Hz
For screw fixing

3TC74 3TC78

4
Size Utiliza- Oper- Ratings of Auxil- Rated Screw terminals PU PS* PG
tion cat- ational DC motors iary control (UNIT,
egory1) cur- at con- supply SET, M)
rent Ie tacts2) voltage
Ver- Us
sion
110 V 220 V 440 V 600 V 750 V 1 200 V 1 500 V Article No. Price
per PU

A kW kW kW kW kW kW kW NO NC V
3TC74 1-pole contactors · Operational voltage up to 750 V
DC operation
12 DC-3, 400 35 70 140 200 250 -- -- 4 4 24 DC 3TC7414-0EB 1 1 unit 41B
DC-5 110 DC 3TC7414-0EF 1 1 unit 41B
AC operation, 50 Hz
12 DC-3, 400 35 70 140 200 250 -- -- 4 4 230/220 3TC7414-1CM 1 1 unit 41B
DC-5 AC3)
3TC78 2-pole contactors · Operational voltage up to 1 500 V
DC operation
12 DC-3, 400 35 70 140 200 250 400 500 4 4 24 DC 3TC7814-0EB 1 1 unit 41B
DC-5 110 DC 3TC7814-0EF 1 1 unit 41B
AC operation, 50 Hz
12 DC-3, 400 35 70 140 200 250 400 500 4 4 230/220 3TC7814-1CM 1 1 unit 41B
DC-5 AC3)
1) Permissible load for DC-1 utilization category, see detailed technical Other rated control supply voltages according to page 4/78
specifications in the Reference Manual. on request.
2)
The fitting of auxiliary switches cannot be altered on DC-operated
contactors. Spare parts, see page 4/80.
3)
Upper operating range limit at 230 V AC: 1.14 x Us.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/77
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
3TC contactors for switching DC voltage, 1- and 2-pole

■ Options
Rated control supply voltages,
possible on request (change of the 10th and 11th digits of the article number)
Delivery time on request
Rated control supply Contactor type 3TC44 3TC48 3TC52/3TC56 3TC74/3TC78
voltage Us

DC operation
24 V DC B4 B4 B4 B
48 V DC W4 W4 -- --
60 V DC E4 E4 -- --
110 V DC F4 F4 F4 F
4

125 V DC G4 G4 -- --
220 V DC M4 M4 M4 M
230 V DC P4 P4 -- --
AC operation
Solenoid coils for 50 Hz
24 V AC B0 B0 -- --
110 V AC F0 F0 F0 --
230/220 V AC P01) P01) P01) M2)
240 V AC U0 U0 -- --
Solenoid coils for 50/60 Hz
24 V AC C2 -- -- --
110 V AC G2 -- -- --
120 V AC K2 -- -- --
220 V AC N2 -- -- --
230 V AC L2 -- -- --
1) 2)
Operating range at 220 V AC: 0.85 to 1.15 × Us; Upper operating range limit at 230 V AC: 1.14 x Us.
lower operating range limit according to IEC 60947.

■ Accessories
For contactors Version Auxiliary switches Screw terminals PU PS* PG
Auxiliary Left Right (UNIT,
contacts SET, M)
Article No. Price
per PU

Size Type NO NC
Second auxiliary switch (for AC operation only)
4 3TC48 2nd auxiliary switch, left 3TY6501-1K 1 1 unit 41B
1 1 53 61 --

54 62
2nd auxiliary switch, right 3TY6501-1L 1 1 unit 41B
1 1 -- 71 83

72 84
8 and 12 3TC52, 2nd auxiliary switch, left 3TY6561-1K 1 1 unit 41B
3TC56 1 1 53 61 --

54 62
2nd auxiliary switch, right 3TY6561-1L 1 1 unit 41B
1 1 -- 71 83

72 84

Solid-state compatible auxiliary switches


For operation in dusty atmospheres and in
solid-state circuits with rated operational currents
Ie/AC-14 and DC-13 of 1 ... 300 mA at 3 ... 60 V
2 and 4 3TC44, 2nd auxiliary switch, left or right 3TY7561-1UA00 1 1 unit 41B
3TC48 (replacement for 3TY6561-1U, 3TY6561-1V)
1 CO contact 51 61

52 54 62 64
5TY7561-1.

* You can order this quantity or a multiple thereof.


4/78 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
3TC contactors for switching DC voltage, 1- and 2-pole

For contactors Version Rated control supply Article No. Price PU PS* PG
voltage Us per PU (UNIT,
SET, M)
Size Type V AC V DC
Surge suppressors · Varistors
2 3TC441) Varistors2) 24 ... 48 24 ... 70 3TX7402-3G 1 1 unit 41B
With line spacer, 48 ... 127 70 ... 150 3TX7402-3H 1 1 unit 41B
for mounting on 127 ... 240 150 ... 250 3TX7402-3J 1 1 unit 41B
the coil terminal 240 ... 400 -- 3TX7402-3K 1 1 unit 41B
400 ... 600 -- 3TX7402-3L 1 1 unit 41B
4 3TC48 Varistors2) 24 ... 48 24 ... 70 3TX7462-3G 1 1 unit 41B
For sticking onto 48 ... 127 70 ... 150 3TX7462-3H 1 1 unit 41B
3TX7402-3. the contactor base 127 ... 240 150 ... 250 3TX7462-3J 1 1 unit 41B
or for mounting 240 ... 400 -- 3TX7462-3K 1 1 unit 41B
separately

4
400 ... 600 -- 3TX7462-3L 1 1 unit 41B
8 and 12 3TC52, Varistors 24 ... 48 -- 3TX7462-3G 1 1 unit 41B
3TC56 For sticking onto 48 ... 127 -- 3TX7462-3H 1 1 unit 41B
the contactor base 127 ... 240 -- 3TX7462-3J 1 1 unit 41B
or for mounting 240 ... 400 -- 3TX7462-3K 1 1 unit 41B
separately 400 ... 600 -- 3TX7462-3L 1 1 unit 41B
3TX7462-3. 8 and 12 3TC52, Varistors2) -- 24 ... 70 3TX7522-3G 1 1 unit 41B
3TC56 For separate screw -- 70 ... 150 3TX7522-3H 1 1 unit 41B
fixing or snapping -- 150 ... 250 3TX7522-3J 1 1 unit 41B
onto TH 35 DIN rail

3TX7522-3.
Surge suppressors · RC elements
4 3TC48 RC elements 24 ... 48 -- 3TX7462-3R 1 1 unit 41B
For lateral -- 24 ... 70 3TX7522-3R 1 1 unit 41B
snapping onto 48 ... 127 -- 3TX7462-3S 1 1 unit 41B
auxiliary switch or -- 70 ... 150 3TX7522-3S 1 1 unit 41B
TH 35 DIN rail
127 ... 240 -- 3TX7462-3T 1 1 unit 41B
-- 150 ... 250 3TX7522-3T 1 1 unit 41B
240 ... 400 -- 3TX7462-3U 1 1 unit 41B
400 ... 600 -- 3TX7462-3V 1 1 unit 41B
3TX7462-3., 8 and 12 3TC52, RC elements 24 ... 48 -- 3TX7522-3R 1 1 unit 41B
3TX7522-3. 3TC56 For lateral 48 ... 127 -- 3TX7522-3S 1 1 unit 41B
snapping onto 127 ... 240 -- 3TX7522-3T 1 1 unit 41B
auxiliary switch or 240 ... 400 -- 3TX7522-3U 1 1 unit 41B
TH 35 DIN rail 400 ... 600 -- 3TX7522-3V 1 1 unit 41B
Surge suppressors · Diodes
4 to 12 3TC48, Diode -- 24 ... 250 3TX7462-3D 1 1 unit 41B
3TC52, assemblies3)
3TC56 (Diode and Zener
diode) for DC
solenoid system,
for sticking onto the
contactor base or
for mounting
3TX7462-3. separately
1) 2)
The connection piece for mounting the surge suppressor must be bent Includes the peak value of the alternating voltage on the DC side.
slightly. 3) Not for DC operation.

For contactors Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)
Size Type
Terminal covers
2 3TC44 For protection against inadvertent -- 3TY2444-0B 1 1 unit 41B
contact with exposed busbar
connections (1 set = 2 units)
6 3TC48 For protection against inadvertent M6 3TX6506-3B 1 1 unit 41B
8 and 12 3TC52, contact with exposed busbar M10 3TX6546-3B 1 1 unit 41B
3TC56 connections
3TX6546-3B Can be screwed on free screw end;
covers one busbar connection
(1 set = 6 units)

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 4/79
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Special applications


Contactors for special applications
3TC contactors for switching DC voltage, 1- and 2-pole

■ Spare parts
For contactors Version Auxiliary Auxiliary switches Screw terminals PU (UNIT, PS* PG
contacts Left Right SET, M)
Article No. Price
per PU

Size Type NO NC
Auxiliary switches
For lateral mounting
2 and 4 3TC44, Auxiliary switch 1 1 13 21 31 43 3TY6501-1AA00 1 1 unit 41B
3TC48 (replacement for
3TY6501-1A,
3TY6501-1B) 14 22 32 44
4

8 and 12 3TC52, Auxiliary switch, 1 1 13 21 -- 3TY6561-1A 1 1 unit 41B


3TC56 left

14 22
3TY6561-1A Auxiliary switch, 1 1 -- 31 43 3TY6561-1B 1 1 unit 41B
right

32 44
12 3TC74 Auxiliary 4 4 13 21 31 43 53 61 71 83 3TY2741-2J 1 1 unit 41B
switches
14 22 32 44 54 62 72 84

12 3TC78 Auxiliary switch, 2 2 13 21 31 43 -- 3TY2781-2C 1 1 unit 41B


left
14 22 32 44
Auxiliary switch, 2 2 -- 53 61 71 83 3TY2781-2D 1 1 unit 41B
right

54 62 72 84

For contactors Version Rated control supply Article No. Price PU (UNIT, PS* PG
voltage Us per PU SET, M)
Size Type V AC/DC
Surge suppressors  Varistors
12 3TC7 For sticking onto the 24 3TX2746-2F 1 1 unit 41B
contactor base 110 3TX2746-2G 1 1 unit 41B

For contactors Version Article No. Price PU (UNIT, PS* PG


per PU SET, M)
Size Type
Solenoid coils
DC operation1)
2 3TC44 -- 3TY6443-0B..
4 3TC48 3TY6483-0B..
8 3TC52 3TY6523-0B..
12 3TC56 3TY6563-0B..
AC operation1)
2 3TC44 -- 3TY7403-0A..
4 3TC48 3TY6483-0A..
8 3TC52 3TY6523-0A..
12 3TC56 3TY6566-0A..
Contacts with fixing parts
In order to ensure reliable operation of the contactors,
only original spare contacts should be used.
2 3TC44 (1 set = 2 moving and 4 fixed contacts) 3TY2440-0A 1 1 unit 41B
4 3TC48 3TY2480-0A 1 1 unit 41B
3TY2520-0A 8 3TC52 3TY2520-0A 1 1 unit 41B
12 3TC56 3TY2560-0A 1 1 unit 41B
12 3TC7 Main contacts (1 set) 3TY2740-0E 1 1 unit 41B
For 3TC78: 2 units required per contactor
Arc chutes
2 3TC44 Arc chutes, 2-pole 3TY2442-0A 1 1 unit 41B
4 3TC48 3TY2482-0A 1 1 unit 41B
8 3TC52 3TY2522-0A 1 1 unit 41B
12 3TC56 3TY2562-0A 1 1 unit 41B
12 3TC7 For 3TC78: 2 units required per contactor 3TY2742-0C 1 1 unit 41B

3TY2482-0A
1)
Rated control supply voltages, see page 4/78. The 10th and 11th digits of
the article number must be supplemented accordingly.

* You can order this quantity or a multiple thereof.


4/80 Siemens IC 10 · 2023 Illustrations are approximate
5
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays

Price groups
PG 41A, 41B, 41H, 41L

5/2 Introduction

Contactor relays
5/5 SIRIUS 3RH2 contactor relays,
4- and 8-pole
5/14 3TH4 contactor relays,
8- and 10-pole
5/20 - Accessories for 3TH4 contactor relays
Contactors for railway applications
4/63 - SIRIUS 3RH2 contactor relays with
extended operating range
4/66 - 3TH4 contactor relays, 8-pole

5
Coupling relays
5/21 SIRIUS 3RQ1 force-guided coupling
relays, fail-safe up to SIL 3/PL e
NEW NEU

5/29 SIRIUS 3RQ2 coupling relays with


industrial enclosure
5/33 SIRIUS 3RQ3 coupling relays,
narrow design
5/42 LZS coupling relays with plug-in relays

3/138 3TG10 power relays/miniature


contactors

Siemens IC 10 · 2023
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays

Introduction

■ Overview
More information
Homepage, see www.siemens.com/sirius Conversion tool, see www.siemens.com/conversion-tool
Industry Mall, see www.siemens.com/product?3RH_3TH

The advantages at a glance

Size S00 S00 -- --


Type 3RH21 3RH22 3TH42 3TH43
5

Article No. Page


SIRIUS 3RH2 contactor relays
4-pole • Screw or spring-loaded terminals 3RH21 5/10, 5/11
8-pole 3RH22 5/10, 5/11
4-pole, latched 3RH24 5/10, 5/11
Coupling contactor relays • Coils for control by the PLC 3RH21 5/12, 5/13
Contactor relays • Coils with extended voltage range 3RH21 4/65
for railway applications
3TH4 contactor relays
8-pole • Screw terminals 3TH42 5/17
10-pole 3TH43 5/18
Contactor relays • Coils with extended voltage range 3TH42 4/66
for railway applications
Accessories for SIRIUS 3RH2 contactor relays
Auxiliary switches • On the front 3RH29, from 3/81 onwards,
3RA281. 3/95
• Lateral 3RH29 3/91
Function modules • On the front 3RA281., 3RA283. 3/100
(direct-on-line starting, star-delta
(wye-delta) starting)
Surge suppressors • On the front 3RT2916 3/97, 3/98
Additional load modules • On the front 3RT2916 3/114

Note:
Safety characteristics for contactors, see "Standards and
approvals", page 16/9.

5/2 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays

Introduction

More information
Homepage, see www.siemens.com/sirius-coupling-relays
Industry Mall, see www.siemens.com/product?3RQ_3RS_LZ
TIA Selection Tool Cloud (TST Cloud), see
www.siemens.com/tstcloud/?node=SIRIUSRelais
Video: Overview of SIRIUS coupling relays
Conversion tool, see www.siemens.com/conversion-tool

The advantages at a glance

Type 3RQ1 3RQ2 3RQ3 LZS/LZX

5
Article No. Page
SIRIUS 3RQ1 force-guided coupling relays, fail-safe up to SIL 3/PL e
Coupling relays with • Widths 17.5 and 22.5 mm 3RQ1 5/21
force-guided contacts • Safety certification according to functional safety SIL 3/PL e
• Can be used as output extension for SIRIUS 3SK safety relays via
device connectors
SIRIUS 3RQ2 coupling relays with industrial enclosure
Coupling relays with relay output • 1, 2 or 3 changeover contacts with wide voltage range 3RQ2 5/29
• Also available with hard gold-plated contacts
SIRIUS 3RQ3 coupling relays, narrow design
Coupling relays with relay output • Width 6.2 mm, 1 CO,
(not plug-in) versions with hard gold-plated contacts optionally available
- Output coupling links 3RQ301 5/33
- Input coupling links 3RQ303 5/33
Coupling relays with plug-in • Width 6.2 mm, 1 CO,
relays versions with hard gold-plated contacts optionally available
- Output coupling links 3RQ311 5/33
Coupling relays • Width 6.2 mm, output 1 semiconductor, triac or transistor
with semiconductor output - Output coupling links 3RQ305, 3RQ306 5/33
(not plug-in) - Input coupling links 3RQ307 5/33
LZS coupling relays with plug-in relays
Coupling relays with plug-in • Switching capacity 12 A/10 A/6 A LZS:PT, LZX:PT 5/48 ... 5/50
relays with 2, 3 and 4 changeover • Width 27 mm
contacts • Base with or without logical separation
Coupling relays with plug-in • Switching capacity 10 A LZS:MT, LZX:MT 5/48
relays with 3 changeover • 11-pole circular base
contacts and circular base • Width 38 mm
Coupling relays with plug-in • Switching capacity 16 A/8 A LZS:RT, LZX:RT 5/49
relays with 1 or 2 changeover • Width 15.5 mm
contacts • Base with or without logical separation

Siemens IC 10 · 2023 5/3


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays

Introduction
Connection methods Ordering notes for multi-unit packaging
The contactor relays and the relays are available with screw On request, 3RQ1 and 3RQ2 coupling relays can also be
terminals (box terminals) or with spring-loaded terminals. ordered in practical and environmentally friendly multi-unit
packaging.
The 3RQ coupling relays are supplied with screw terminals or
spring-loaded (push-in) terminals. The plug-in sockets for Multi-unit packaging with order code X90
LZS/LZX coupling relays are also available with plug-in (push-in)
terminals. When ordering products in multi-unit packaging, the article number
of the product concerned must be supplemented with "-Z" and,
in addition, the order code "X90" must be specified.
Screw terminals
Ordering examples:
Spring-loaded terminals, • 3RQ10 coupling relays with a width of 17.5 mm
spring-loaded terminals (push-in) 3RQ1000-1EB00-Z X90;
Order quantity 16 units  Delivered in one package
Flat connectors containing 16 units
• 3RQ20 coupling relays with a width of 22.5 mm
3RQ2000-1AW00-Z X90;
Plug-in terminals (push-in) Order quantity 12 units  Delivered in one package
containing 12 units
5

The terminals are indicated in the corresponding


tables by the symbols shown on orange backgrounds. For more information, see page 16/7.

3RQ coupling relays: Spring-loaded terminals (push-in) with


TOP wiring
Push-in terminals are a form of spring-loaded terminals allowing
fast wiring without tools for rigid conductors or conductors
equipped with end sleeves.
As with other spring-type terminals, a screwdriver (with
3.0 x 0.5 mm blade) is required to disconnect the conductor.
The same tool can also be used to wire finely-stranded or
stranded conductors with no end finishing.
The advantages of the push-in terminals are found, as with all
spring-loaded terminals, in speed of assembly and disassembly
and vibration-proof connection. There is no need for the
checking and tightening required with screw terminals.
With the TOP wiring method, the wire inlet and terminals can be
reached from the front. This helps to speed up the wiring
process and eliminate wiring errors.

Video: SIRIUS spring-loaded terminals - Strong, flexible, safe, fast

5/4 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
SIRIUS 3RH2 contactor relays, 4- and 8-pole

■ Overview
Contactor relays,
size S00, with accessories

10

11
11
1

5
IC01_00632c
8
9
3

12
13 14
11
6
4
5 11
7

10
1 Contactor relay
2 Coupling contactor relay for auxiliary circuits

3 3RA28 function module 10 Solder pin adapter for contactor relays with 4-pole auxiliary switch
4 1-pole auxiliary switch, cable entry from the top 11 Solder pin adapter
5 2-pole auxiliary switch, cable entry from the top 12 Additional load module for increasing the permissible residual current
6 1-pole auxiliary switch, cable entry from the bottom 13 Surge suppressor with LED
7 2-pole auxiliary switch, cable entry from the bottom 14 Surge suppressor without LED
8 4-pole auxiliary switch
(terminal designations according to EN 50011 or EN 50005)
For contactor relays
9 2-pole auxiliary switch, solid-state compatible version
(terminal designations according to EN 50005) For contactor relays and coupling contactor relays

Accessories, see page 3/69 onwards.

Siemens IC 10 · 2023 5/5


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
SIRIUS 3RH2 contactor relays, 4- and 8-pole
Standards Accessories
IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1 The accessories for the 3RT2 contactors in size S00 can also be
used for the 3RH2 contactor relays (see page 3/69 onwards).
The 3RH2 contactor relays are available with screw or spring-
loaded terminals. The basic unit contains four contacts with Mounting of additional auxiliary switches
terminal designations according to EN 50011.
Expansion possibilities
The 3RH21 coupling contactor relays for switching auxiliary
circuits are tailored to the special requirements of working with All 3RH21 contactor relays (except for coupling contactor
electronic controls. relays) can be expanded using auxiliary switches;
the permissible configuration must be observed.
Contact reliability of auxiliary contacts
For detailed information about fitting of auxiliary switches, see
High contact stability at low voltages and currents, suitable for pages 3/81 to 3/86.
solid-state circuits with currents  1 mA at a voltage of  17 V.
The auxiliary switch can easily be snapped onto the front of the
Protection of the device connections against overvoltage contactor relays. The auxiliary switch has a centrally positioned
release lever for disassembly.
Protection against overvoltage at the control supply voltage
connection The conventional front auxiliary contacts fulfill the characteristics
of force-guided operation and are therefore suitable for safety
RC elements, varistors, diodes or diode assemblies
5

applications.
(combination of a diode and a Zener diode) can be plugged
onto all 3RH2 contactor relays from the front for damping Contactor relays in safety-related applications
opening surges in the coil. The plug-in direction is determined
by a coding device. Contactor relays are a significant part of safety-related
applications. They are generally the actuators that perform
Coupling contactor relays have a low power consumption and the switching operation leading to the safe disconnection
an extended solenoid coil operating range. of the corresponding application or system.
Depending on the version, the solenoid coils of the coupling Contactor relays with force-guided operation according to
contactor relays are supplied either without overvoltage IEC 60947-5-1 are generally required for use in safety-related
damping (versions 3RH21..-.HB40 or 3RH21..-.MB40-0KT0) applications. Most of our contactors meet this requirement;
or with a diode or suppressor diode connected as standard. a corresponding note can be found in the technical product
data sheet.
Note:
The break times of the contactor, the opening delay times of the Contactor relays with increased tamper protection
NO contacts and the closing delay times of the NC contacts Increased tamper protection is ensured either by using our
increase with damping. contactor relay versions with permanently mounted auxiliary
For more information on how damping influences the time switches installed in the factory (e.g. 3RH22 contactor relays),
response, see the Equipment Manual. or by using the 3RT2916-4MA10 sealable cover as an accessory
(see page 3/112).

Article number scheme


Product versions Article number
SIRIUS contactor relays 3RH2 @ @ @ – @ @ @ @ 0 – @ @ @ @
Device type e.g. 1 = 4-pole contactor relay @
Number of NO contacts e.g. 2 = 2 NO @
Number of NC contacts e.g. 2 = 2 NC @
Type of electrical connection Screw terminals 1
Spring-loaded terminals 2
Operating range/solenoid coil circuit e.g. A = AC standard/without coil circuit @
Rated control supply voltage e.g. P0 = 50/60 Hz 230 V AC @@
Special version @@@@
Example 3RH2 1 2 2 – 1 A P 0 0
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted
versions for better understanding of the logic behind the article in the selection and ordering data.
numbers.

5/6 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
SIRIUS 3RH2 contactor relays, 4- and 8-pole

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/16188/td https://support.industry.siemens.com/cs/ww/en/ps/16188/man
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16188/faq

Contactor relays
Type 3RH2
Size S00
Permissible mounting position
The contactor relays are designed for operation

NSB0_00478c
360° 22,5° 22,5°
on a vertical mounting surface.

Upright mounting position

5
NSB0_00477a
Special version required
(in the case of coupling contactor relays and contactor relays with extended
operating range 3RH2122-2K.40 on request)
Force-guided operation of contacts in contactor relays
3RH2: Explanations:
Yes, in the basic unit and the auxiliary switch as well as between the There is force-guided operation if it is ensured that the NC and NO contacts
basic unit and the mounted auxiliary switch (removable) according to: cannot be closed at the same time.
• ZH1/457
• IEC 60947-5-1, Annex L ZH1/457
3RH22: Safety Rules for Controls on Power-Operated Metalworking Presses.
Yes, in the basic unit and the auxiliary switch as well as between the
basic unit and the mounted auxiliary switch (permanently mounted) IEC 60947-5-1, Annex L
according to: Standard for low-voltage switchgear and controlgear; "Special requirements
• ZH1/457 for mechanically linked contact elements"
• IEC 60947-5-1, Annex L
Note:
3RH2911-.NF. solid-state-compatible auxiliary switches have
no force-guided contacts.
Contact reliability
Contact reliability at 17 V, 1 mA according to IEC 60947-5-4 Frequency of contact faults <10-8, i.e. < 1 fault per 100 million operating cycles
Contact endurance for AC-15/AC-14 and
DC-13 utilization categories
The contact endurance is mainly dependent on the breaking current.
It is assumed that the operating mechanisms are switched arbitrarily and 30 NSB0_02061d
not synchronously with the phase angle of the supply system switching Basic unit
operating mechanism.
Million operating cycles (106)

10
If magnetic circuits other than the contactor operating mechanisms or
5 Basic unit with
solenoid valves are present, e.g. magnetic brakes, protective measures 4
for the load circuits are necessary, e.g. in the form of RC elements and 3 attachable
contact block AC-15/AC-14
freewheeling diodes. 2
DC-13 DC-13 Basic unit with
The characteristic curves apply to 1 220 V 110 V attachable
• 3RH21/3RH22 contactor relays1) 0,5 contact block
• 3RH24 latched contactor relays
• 3RH2911 auxiliary switches1) DC-13
• Auxiliary switches for snapping onto the front, 24 V
max. 4-pole and for mounting on the side in size S00 0,1
1)
0,05

0,01
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 6 7 10 a (A)
e -DC-13 e -DC-13 e -DC-13 e -AC-15
220 V 110 V 24 V < 230 V
Diagram legend:
a = Breaking current
e = Rated operational current

1)
3RH22, 3RH2911: Ie = 6 A for AC-15/AC-14 and DC-13.

Siemens IC 10 · 2023 5/7


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
SIRIUS 3RH2 contactor relays, 4- and 8-pole

Contactor relays
Type 3RH21 3RH22 3RH24
Size S00
General data
Dimensions (W x H x D)
• Basic units

H
- Screw terminals mm 45 x 58 x 73 -- 90 x 58 x 73
- Spring-loaded terminals mm 45 x 70 x 73 --

D
W
• Basic unit with mounted auxiliary switch
- Screw terminals mm 45 x 58 x 117 --
- Spring-loaded terminals mm 45 x 70 x 121 --
• Basic unit with mounted function module
or solid-state time-delay auxiliary switch
- Screw terminals mm 45 x 58 x 147 --
- Spring-loaded terminals mm 45 x 70 x 147 --
Mechanical endurance
5

• Basic units Operat- 30 million 5 million


ing
cycles
• Basic unit with mounted auxiliary switch Operat- 10 million 5 million
ing
cycles
• Solid-state-compatible auxiliary switch Operat- 5 million
ing
cycles
Rated insulation voltage Ui (pollution degree 3) V 690
Rated impulse withstand voltage Uimp kV 6
Protective separation between coil and contacts in the basic unit, V 400
according to IEC 60947-1, Annex N
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -55 ... +80
Short-circuit protection
• Short-circuit test
- With fuse links of operational class gG: A 10
DIAZED, type 5SB; NEOZED, type 5SE
with short-circuit current Ik = 1 kA according to IEC 60947-5-1
- With miniature circuit breakers with C characteristic A 6
with short-circuit current Ik = 400 A according to IEC 60947-5-1

Contactor relays
Type 3RH21 3RH22 3RH24
Size S00
Conductor cross-sections
Auxiliary conductors and coil terminals Screw terminals
(1 or 2 conductors can be connected)
• Solid or stranded mm2 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1), max. 2 x 4
• Finely stranded with end sleeve mm2 2 x (0.5 ... 1.5)1); 2 x (0.75 ... 2.5)1)
• AWG cables, solid or stranded AWG 2 x (20 ... 16)1); 2 x (18 ... 14)1)
• Terminal screw M3 (for Pozidriv size 2,  5 ... 6 mm)
- Tightening torque Nm 0.8 ... 1.2 (7 ... 10.3 lb.in)
Auxiliary conductors and coil terminals2) Spring-loaded terminals
(1 or 2 conductors can be connected)
• Operating devices mm 3.0 x 0.5; 3.5 x 0.5
• Solid or stranded mm2 2 x (0.5 ... 4)
• Finely stranded with end sleeve mm2 2 x (0.5 ... 2.5)
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 12)
Auxiliary conductors for front and laterally mounted auxiliary switches2)
• Operating devices mm 3.0 x 0.5; 3.5 x 0.5
• Solid or stranded mm2 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve mm2 2 x (0.5 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in one of the ranges specified.
2)
Max. external diameter of the conductor insulation: 3.6 mm.
On spring-loaded terminals with conductor cross-sections  1 mm2
an insulation stop is recommended, see page 3/115.

5/8 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
SIRIUS 3RH2 contactor relays, 4- and 8-pole

Contactor relays
Type 3RH2
Size S00
Control
Solenoid coil operating range
• AC operation at 50 Hz 0.8 ... 1.1 x Us
at 60 Hz 0.85 ... 1.1 x Us
• DC operation at +50 °C 0.8 ... 1.1 x Us
at +60 °C 0.85 ... 1.1 x Us
Power consumption of the solenoid coil
(for cold coil and 1.0 x Us)
• AC operation, 50 Hz
- Closing VA/p.f. 37/0.8
- Closed VA/p.f. 5.7/0.25
• AC operation, 60 Hz
- Closing VA/p.f. 33/0.75
- Closed VA/p.f. 4.4/0.25

5
• DC operation W 4.0
Closing = Closed
Permissible residual current of the electronics
(with 0 signal)
• For AC operation1) < 4 mA x (230 V/Us)
• For DC operation < 10 mA x (24 V/Us)
1)
The 3RT2916-1GA00 additional load module is recommended for higher
residual currents, see page 3/114.

Coupling contactor relays


Type 3RH21..
-.HB40 -.JB40 -.KB40 -.MB40-0KT0 -.VB40 -.SB40
Size S00
Control
Solenoid coil operating range 0.7 ... 1.25 x Us 0.85 ... 1.85 x Us
Power consumption of the solenoid coil W 2.8 1.6
(for cold coil and 1.0 x Us)
Closing = Closed
at Us = 24 V
Permissible residual current <10 mA x (24 V/Us) < 8 mA x (24 V/Us)
of the electronics with 0 signal
Overvoltage configuration of No overvoltage Inte- Integrated No overvoltage Inte- Integrated
the solenoid coil damping grated suppressor damping grated suppressor
diode diode diode diode

Contactor relays
Type 3RH2
Size S00
Rated data of the auxiliary contacts
Load rating with AC
Rated operational currents Ie
AC-12 A 10
AC-15/AC-14, at rated operational voltage Ue
Up to 230 V A 101)
400 V A 3
500 V A 2
690 V A 1
s and u rated data
Basic units and auxiliary switches
• Rated control supply voltage V AC max. 600
• Rated voltage V AC 600
• Switching capacity A 600, Q 600
• Uninterrupted current at 240 V AC A 10
1)
3RH22, 3RH29: Ie = 6 A for AC-15/AC-14 and DC-13.

Siemens IC 10 · 2023 5/9


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
SIRIUS 3RH2 contactor relays, 4- and 8-pole

■ Selection and ordering data


AC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41A

3RH2122-1A..0 3RH2122-2A..0 3RH2244-1A..0 3RH2244-2A..0 3RH2422-1A..0


5

Rated operational current Contacts Rated control supply Screw terminals Spring-loaded
Ie/AC-15/AC-14 voltage Us terminals
at 230 V Ident. No. Version at 50/60 Hz1)
Article No. Price Article No. Price
per PU per PU

A NO NC V AC
For screw and snap-on mounting on TH 35 DIN rail
Size S00
10 40E 4 -- 24 3RH2140-1AB00 3RH2140-2AB00
110 3RH2140-1AF00 3RH2140-2AF00
230 3RH2140-1AP00 3RH2140-2AP00
31E 3 1 24 3RH2131-1AB00 3RH2131-2AB00
110 3RH2131-1AF00 3RH2131-2AF00
230 3RH2131-1AP00 3RH2131-2AP00
22E 2 2 24 3RH2122-1AB00 3RH2122-2AB00
110 3RH2122-1AF00 3RH2122-2AF00
230 3RH2122-1AP00 3RH2122-2AP00
With permanently mounted auxiliary switch
6 44E 4 4 230 3RH2244-1AP00 3RH2244-2AP00
62E 6 2 230 3RH2262-1AP00 3RH2262-2AP00
Latched
No lateral auxiliary switches can be mounted
10 40 E 4 -- 24 3RH2440-1AB00 --
110 3RH2440-1AF00 --
230 3RH2440-1AP00 --
31 E 3 1 24 3RH2431-1AB00 --
110 3RH2431-1AF00 --
230 3RH2431-1AP00 --
22 E 2 2 24 3RH2422-1AB00 --
110 3RH2422-1AF00 --
230 3RH2422-1AP00 --
1) Coil operating range Other voltages according to page 3/67 on request.
- at 50 Hz: 0.8 to 1.1 x Us
- at 60 Hz: 0.85 to 1.1 x Us. Accessories, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


5/10 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
SIRIUS 3RH2 contactor relays, 4- and 8-pole
DC operation
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41A

3RH2122-1B..0 3RH2122-2B..0 3RH2244-1B..0 3RH2244-2B..0 3RH2422-1B.40

Rated operational current Contacts Rated control supply Screw terminals Spring-loaded
Ie/AC-15/AC-14 Ident. No. Version voltage Us terminals
at 230 V

5
Article No. Price Article No. Price
per PU per PU

A NO NC V DC
For screw and snap-on mounting on TH 35 DIN rail
Size S00
10 40E 4 -- 24 3RH2140-1BB40 3RH2140-2BB40
220 3RH2140-1BM40 3RH2140-2BM40
31E 3 1 24 3RH2131-1BB40 3RH2131-2BB40
220 3RH2131-1BM40 3RH2131-2BM40
22E 2 2 24 3RH2122-1BB40 3RH2122-2BB40
220 3RH2122-1BM40 3RH2122-2BM40
With integrated coil circuit (diode integrated at the factory)
10 40E 4 -- 24 3RH2140-1FB40 3RH2140-2FB40
31E 3 1 24 3RH2131-1FB40 3RH2131-2FB40
22E 2 2 24 3RH2122-1FB40 3RH2122-2FB40
With permanently mounted auxiliary switch
6 44E 4 4 24 3RH2244-1BB40 3RH2244-2BB40
62E 6 2 24 3RH2262-1BB40 3RH2262-2BB40
Latched
No lateral auxiliary switches can be mounted
10 40E 4 -- 24 3RH2440-1BB40 --
110 3RH2440-1BF40 --
220 3RH2440-1BM40 --
31E 3 1 24 3RH2431-1BB40 --
110 3RH2431-1BF40 --
220 3RH2431-1BM40 --
22E 2 2 24 3RH2422-1BB40 --
110 3RH2422-1BF40 --
220 3RH2422-1BM40 --

Other voltages according to page 3/67 on request.


Accessories, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 5/11
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
SIRIUS 3RH2 contactor relays, 4- and 8-pole
DC operation for direct control by PLC
• Coupling contactor relays with adapted power consumption
• Suitable for solid-state PLC outputs
• Cannot be expanded with auxiliary switches
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41A

3RH21..-1.B40 3RH21..-2.B40
5

Rated operational current Auxiliary contacts Rated control Screw terminals Spring-loaded
Ie/AC-15/ AC-14 Ident. No. Version supply voltage Us terminals
at 230 V according
to
EN 50011
Article No. Price Article No. Price
per PU per PU

A NO NC V DC
For screw and snap-on mounting on TH 35 DIN rail
Size S00
Cannot be expanded with auxiliary switches
Operating range 0.7 to 1.25 x Us,
power consumption of the solenoid coils 2.8 W at 24 V
10 40E 4 -- 24 3RH2140-1HB40 3RH2140-2HB40
31E 3 1 24 3RH2131-1HB40 3RH2131-2HB40
22E 2 2 24 3RH2122-1HB40 3RH2122-2HB40
Operating range 0.85 to 1.85 x Us,
power consumption of the solenoid coils 1.6 W at 24 V
10 40E 4 -- 24 3RH2140-1MB40-0KT0 3RH2140-2MB40-0KT0
31E 3 1 24 3RH2131-1MB40-0KT0 3RH2131-2MB40-0KT0
22E 2 2 24 3RH2122-1MB40-0KT0 3RH2122-2MB40-0KT0

Other voltages according to page 3/67 on request.


Accessories, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


5/12 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
SIRIUS 3RH2 contactor relays, 4- and 8-pole
DC operation for direct control by PLC
• Coupling contactor relays with adapted power consumption
• Suitable for solid-state PLC outputs
• Cannot be expanded with auxiliary switches
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41A

5
3RH21..-1.B40 3RH21..-2.B40

Rated operational current Auxiliary contacts Rated control Screw terminals Spring-loaded
Ie/AC-15/ AC-14 Ident. No. Version supply voltage Us terminals
at 230 V according
to
EN 50011
Article No. Price Article No. Price
per PU per PU

A NO NC V DC
For screw and snap-on mounting on TH 35 DIN rail
Size S00
With integrated coil circuit (diode integrated at factory)
Cannot be expanded with auxiliary switches
Operating range 0.7 to 1.25 x Us
Power consumption of the solenoid coils 2.8 W at 24 V
10 40E 4 -- 24 3RH2140-1JB40 3RH2140-2JB40
31E 3 1 24 3RH2131-1JB40 3RH2131-2JB40
22E 2 2 24 3RH2122-1JB40 3RH2122-2JB40
Operating range 0.85 to 1.85 x Us
Power consumption of the solenoid coils 1.6 W at 24 V
10 40E 4 -- 24 3RH2140-1VB40 3RH2140-2VB40
31E 3 1 24 3RH2131-1VB40 3RH2131-2VB40
22E 2 2 24 3RH2122-1VB40 3RH2122-2VB40
With integrated coil circuit (suppressor diode integrated at factory)
Cannot be expanded with auxiliary switches
Operating range 0.7 to 1.25 x Us
Power consumption of the solenoid coils 2.8 W at 24 V
10 40E 4 -- 24 3RH2140-1KB40 3RH2140-2KB40
31E 3 1 24 3RH2131-1KB40 3RH2131-2KB40
22E 2 2 24 3RH2122-1KB40 3RH2122-2KB40
Operating range 0.85 to 1.85 x Us
Power consumption of the solenoid coils 1.6 W at 24 V
10 40E 4 -- 24 3RH2140-1SB40 3RH2140-2SB40
31E 3 1 24 3RH2131-1SB40 3RH2131-2SB40
22E 2 2 24 3RH2122-1SB40 3RH2122-2SB40

Other voltages according to page 3/67 on request.


Accessories, see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 5/13
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
3TH4 contactor relays, 8- and 10-pole

■ Overview
Standards Protection of the device connections against overvoltage
IEC 60947-1, IEC 60947-5-1 Protection against overvoltage at the control supply voltage
connection
Note:
The 3TH42 and 3TH43 contactor relays can be equipped with
The 3TH42 and 3TH43 contactor relays feature force-guided RC elements, varistors, diodes or diode assemblies
operation in accordance with IEC 60947-5-1, Ed. 3.1. (combination of a diode and a Zener diode) for damping
Terminal designations according to EN 50011 opening surges. The surge suppressors can be mounted
directly on the coil, see page 5/20.
In terms of their terminal designations, identification numbers
and identification letters, the 3TH42 and 3TH43 contactor Note:
relays conform to the standard EN 50011 for "Particular The break times of the contactor, the opening delay times of the
Contactor Relays". NO contacts and the closing delay times of the NC contacts
Contact reliability of auxiliary contacts increase with damping.

High contact stability at low voltages and currents as a result of For more information on how damping influences the time
double-break contacts, suitable for solid-state circuits with response, see the Equipment Manual.
5

currents  1 mA at a voltage of  17 V. Mounting


Note:
With 3TH4 contactor relays with AC operation, an overvoltage of
1.1 x Us, an ambient temperature  45 °C and 100% ON period
of all contactors, a minimum clearance of 5 mm between the
contactors shall be observed in the case of side-by-side
mounting.

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/16176/td https://support.industry.siemens.com/cs/ww/en/ps/16176/man
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16176/faq

Contactor relays Type 3TH42, 3TH43


Contact endurance for AC-15/AC-14 and
DC-13 utilization categories
The contact endurance is mainly dependent on the breaking current.
It is assumed that the operating mechanisms are switched arbitrarily and 30
NSB0_01391b
not synchronously with the phase angle of the supply system switching
Million operating cycles (10 6 )

operating mechanism.
10
If magnetic circuits other than the contactor operating mechanisms or
solenoid valves are present, e.g. magnetic brakes, protective measures DC-13 AC-15/AC-14
for the load circuits are necessary. 5
4
110 V
RC elements or freewheeling diodes are suitable as protective measures 3
for the circuits.
2
DC-13 DC-13
220 V 24 V
1

0,5

0,1
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10 a (A)
-DC-13 e -DC-13
e -DC-13
e
220 V 110 V 24 V

Diagram legend:
e-AC-15/AC-14
a = Breaking current ≤ 230 V
e = Rated operational current

5/14 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
3TH4 contactor relays, 8- and 10-pole

Contactor relays Type 3TH42 3TH43


General data
Dimensions (W x H x D)
• AC operation mm 45 x 78 x 97 55 x 78 x 97

H
• DC operation mm 45 x 78 x 130 55 x 78 x 130

D
W

Permissible mounting position


The contactor relays are designed for operation
on a vertical mounting surface.
• AC operation

NSB0_00478c
360° 22,5° 22,5°

• DC operation

NSB0_00649a
22,5° 22,5°
90° 90°

5
Upright mounting position
AC and DC operation
NSB0_00477a
Special version required
Mechanical endurance Basic units Operat- 30 million
ing
cycles
Rated insulation voltage Ui V 690
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 8
Protective separation between the coil and the main contacts V Up to 500
according to IEC 60947-1, Annex N
Permissible ambient temperature
• During operation °C -25 ... +55
• During storage °C -55 ... +80
Short-circuit protection
Short-circuit test
• With fuse links of operational class gG
With short-circuit current Ik = 1 kA according to IEC 60947-5-1
- LV HRC, type 3NA A 16
- DIAZED, type 5SB A 16
- NEOZED, type 5SE, quick A 20
• With miniature circuit breakers
With short-circuit current Ik = 400 A according to IEC 60947-5-1
- C characteristic A 16
- B characteristic A 16
s and u rated data
Basic units
Rated control supply voltage Us Max. 600 V AC, 230 V DC (according to UL 240 V DC)
Rated voltage 600 V AC, 600 V DC
Switching capacity A 600, P 600
Conductor cross-sections
Auxiliary conductors and coil terminals Screw terminals
(1 or 2 conductors can be connected)
• Solid or stranded mm2 2 x (0.5 ... 1)1); 2 x (1 ... 2.5)1); 1 x 4
• Finely stranded with end sleeve mm2 2 x (0.75 ... 2.5)
• Terminal screw M3.5
1) If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in one of the ranges specified.

Siemens IC 10 · 2023 5/15


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
3TH4 contactor relays, 8- and 10-pole

Contactor relays Type 3TH42, 3TH43


Control
Solenoid coil operating range
• AC operation 0.8 ... 1.1 x Us1)
• DC operation (except 24 V) 0.8 ... 1.1 x Us
- At 24 V DC 0.8 ... 1.2 x Us
Power consumption of the solenoid coil (for cold coil and 1.0 x Us)
• AC operation, 50 Hz, standard version
- Closing VA/p.f. 68/0.82
- Closed VA/p.f. 10/0.29
• AC operation, 50/60 Hz, standard version
- Closing, 50 Hz VA/p.f. 77/0.81
- Closed, 50 Hz VA/p.f. 11/0.28
- Closing, 60 Hz VA/p.f. 71/0.75
- Closed, 60 Hz VA/p.f. 9/0.27
• AC operation, 50 Hz, USA/Canada
- Closing VA/p.f. 68/0.82
- Closed VA/p.f. 10/0.29
5

• AC operation, 60 Hz, USA/Canada


- Closing VA/p.f. 75/0.76
- Closed VA/p.f. 9.4/0.29 ... 0.3
• AC operation, 50 Hz, Japan
- Closing VA/p.f. 80/0.8
- Closed VA/p.f. 10.7/0.29
• AC operation, 60 Hz, Japan
- Closing VA/p.f. 75 ... 90/0.73
- Closed VA/p.f. 8.5 ... 10.7/0.29 ... 0.3
• DC operation up to 250 V W 6.2
Closing = Closed
Permissible residual current of the electronics (with 0 signal)
• For AC operation  8 mA x (220 V/Us)
• For DC operation  1.25 mA x (220 V/Us)
Rated data of the auxiliary contacts
Load rating with AC
Rated operational currents Ie
• AC-12 A 16
• AC-15/AC-14, 230 V A 10
at rated operational voltage Ue 400 V A 6
500 V A 4
690 V A 2
Rated power of three-phase motors 230/220 V kW 2.4
According to utilization categories AC-3 and AC-3e, 50 Hz 400/380 V kW 4
500 V kW 4
690/660 V kW 4
1)
Coils for USA, Canada and Japan: 0.85 to 1.1 x Us at 60 Hz.

5/16 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
3TH4 contactor relays, 8- and 10-pole

■ Selection and ordering data


8-pole contactor relays
AC operation or DC operation

3TH4280-0AP0 3TH4244-0BB4
Contacts Rated operational current Contacts Screw terminals PU PS* PG
Ie/AC-15/AC-14 (UNIT,
at SET, M)
230/ 400/ 500 V 690/ Ident. No. Version

5
220 V 380 V 660 V according to
EN 50011
Article No. Price
per PU

Number A A A A NO NC NO NC
For screw and snap-on mounting on TH 35 DIN rail
AC operation, rated control supply voltage Us = 50 Hz 230/220 V AC1)
8 10 6 4 2 80E 8 -- -- -- 3TH4280-0AP0 1 1 unit 41A
71E 7 1 -- -- 3TH4271-0AP0 1 1 unit 41A
62E 6 2 -- -- 3TH4262-0AP0 1 1 unit 41A
53E 5 3 -- -- 3TH4253-0AP0 1 1 unit 41A
44E 4 4 -- -- 3TH4244-0AP0 1 1 unit 41A
44E, U 3 3 1 1 3TH4293-0AP0 1 1 unit 41A
DC operation, rated control supply voltage Us = 24 V DC
8 10 6 4 2 80E 8 -- -- -- 3TH4280-0BB4 1 1 unit 41A
71E 7 1 -- -- 3TH4271-0BB4 1 1 unit 41A
62E 6 2 -- -- 3TH4262-0BB4 1 1 unit 41A
53E 5 3 -- -- 3TH4253-0BB4 1 1 unit 41A
44E 4 4 -- -- 3TH4244-0BB4 1 1 unit 41A
44E, U 3 3 1 1 3TH4293-0BB4 1 1 unit 41A
1)
Operating range at 220 V: 0.85 to 1.1 × Us; Other voltages according to page 5/19 on request.
lower operating range limit according to IEC 60947.
Accessories, see page 5/20.
Note:
The solenoid coils of the 3TH42 contactor relays are available in
various voltages as spare parts (on request).
- AC operation: 3TY7403-0A..
- DC operation: 3TY4803-0B..
The contacts cannot be replaced on 3TH42 contactor relays.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 5/17
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
3TH4 contactor relays, 8- and 10-pole
10-pole contactor relays
AC operation or DC operation

3TH4355-0AP0 3TH4355-0BB4
Contacts Rated operational current Contacts Screw terminals PU PS* PG
Ie/AC-15/AC-14 (UNIT,
at SET, M)
230 V 400 V 500 V 690 V Ident. No. Version
according to
EN 50011
Article No. Price
5

per PU

Number A A A A NO NC NO NC
For screw and snap-on mounting on TH 35 DIN rail
AC operation, rated control supply voltage Us = 50 Hz 230/220 V AC1)
10 10 6 4 2 100E 10 -- -- -- 3TH4310-0AP0 1 1 unit 41A
91E 9 1 -- -- 3TH4391-0AP0 1 1 unit 41A
82E 8 2 -- -- 3TH4382-0AP0 1 1 unit 41A
73E 7 3 -- -- 3TH4373-0AP0 1 1 unit 41A
73E, U 6 2 1 1 3TH4346-0AP0 1 1 unit 41A
64E 6 4 -- -- 3TH4364-0AP0 1 1 unit 41A
55E 5 5 -- -- 3TH4355-0AP0 1 1 unit 41A
55E, U 4 4 1 1 3TH4394-0AP0 1 1 unit 41A
DC operation, rated control supply voltage Us = 24 V DC
10 10 6 4 2 100E 10 -- -- -- 3TH4310-0BB4 1 1 unit 41A
91E 9 1 -- -- 3TH4391-0BB4 1 1 unit 41A
82E 8 2 -- -- 3TH4382-0BB4 1 1 unit 41A
73E 7 3 -- -- 3TH4373-0BB4 1 1 unit 41A
73E, U 6 2 1 1 3TH4346-0BB4 1 1 unit 41A
64E 6 4 -- -- 3TH4364-0BB4 1 1 unit 41A
55E 5 5 -- -- 3TH4355-0BB4 1 1 unit 41A
55E, U 4 4 1 1 3TH4394-0BB4 1 1 unit 41A
1)
Operating range at 220 V: 0.85 to 1.1 × Us; Other voltages according to page 5/19 on request.
lower operating range limit according to IEC 60947.
Accessories, see page 5/20.
Note:
The solenoid coils of the 3TH43 contactor relays are available in
various voltages as spare parts (on request).
- AC operation: 3TY7403-0A..
- DC operation: 3TY4803-0B..
The contacts cannot be replaced on 3TH43 contactor relays.

* You can order this quantity or a multiple thereof.


5/18 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
3TH4 contactor relays, 8- and 10-pole

■ Options
Rated control supply voltages, possible on request (change of the 10th and 11th digits of the article number)
Delivery time on request
Contactor type 3TH42/3TH43 Contactor type 3TH42/3TH43
Rated control supply Control supply voltage Rated control supply
voltage Us at voltage Us

AC operation DC operation
Solenoid coils for 50 and 60 Hz AC 12 V DC A4
24 V DC B4
50 Hz 60 Hz
30 V DC C4
24 V AC 29 V AC B0
36 V DC V4
36 V AC 42 V AC G0
42 V DC D4
42 V AC 50 V AC D0
48 V DC W4
48 V AC 58 V AC H0
60 V DC E4
60 V AC 72 V AC E0
110 V DC F4
110 V AC 132 V AC F0
125 V DC G4
125/127 V AC 150/152 V AC L0

5
220 V DC M4
230/220 V AC 276 V AC P01)
230 V DC P4
240 V AC 288 V AC U0
240 V DC Q4
400/380 V AC 480/460 V AC V01)
415 V AC 500 V AC R0
500 V AC 600 V AC S0
50/60 Hz
24 V AC C2
42 V AC D2
110 V AC G2
115 V AC J2
120 V AC K2
220 V AC N2
230 V AC L2
240 V AC P2
440 V AC R2
For Japan
50 Hz 60 Hz
100 V AC 100 ... 110 V AC G62)
200 V AC 200 ... 220 V AC N62)
For USA and Canada
50 Hz 60 Hz
110 V AC 120 V AC K62)
220 V AC 240 V AC P62)
1)
Operating range at 220 V or 380 V: 0.85 to 1.1 x Us.
2)
Operating range at 60 Hz: 0.85 to 1.1 x Us.

Siemens IC 10 · 2023 5/19


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Contactor relays
3TH4 contactor relays, 8- and 10-pole > Accessories for 3TH4 contactor relays

■ Selection and ordering data


Version Rated control supply Article No. Price PU PS* PG
voltage Us per PU (UNIT,
SET, M)
AC DC
V V
Surge suppressors for 3TH4 contactor relays
Interference suppression diodes -- 24 ... 250 3TX7402-3A 1 1 unit 41B
With line spacer,
for mounting on the coil terminal
Diode assemblies -- 24 ... 250 3TX7402-3D 1 1 unit 41B
(diode and Zener diode)
With line spacer,
DC operation,
3TX7402-3. for mounting on the coil terminal
Varistors1) 24 ... 48 24 ... 70 3TX7402-3G 1 1 unit 41B
With line spacer, 48 ... 127 70 ... 150 3TX7402-3H 1 1 unit 41B
for mounting on the coil terminal 127 ... 240 150 ... 250 3TX7402-3J 1 1 unit 41B
5

240 ... 400 -- 3TX7402-3K 1 1 unit 41B


400 ... 600 -- 3TX7402-3L 1 1 unit 41B
RC elements 24 ... 48 24 ... 70 3TX7402-3R 1 1 unit 41B
With line spacer, 48 ... 127 70 ... 150 3TX7402-3S 1 1 unit 41B
for mounting on the coil terminal 127 ... 240 150 ... 250 3TX7402-3T 1 1 unit 41B
240 ... 400 -- 3TX7402-3U 1 1 unit 41B
400 ... 600 -- 3TX7402-3V 1 1 unit 41B
Covers for switch position indicator -- -- 3TX4210-0P 1 1 unit 41B
1)
Includes the peak value of the alternating voltage on the DC side.

For Version Rated control Time setting Screw terminals PU PS* PG


contactors supply voltage Us range (UNIT,
50/60 Hz AC (minimum SET, M)
times)
Article No. Price
Type V s per PU
ON-delay devices
3TH42, NTC 220 ... 230 0.1 3TX4180-0A 1 1 unit 41B
3TH43 thermistors
Time tolerance
+100%, -50%

3TX4180-0A

* You can order this quantity or a multiple thereof.


5/20 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
NEW NEU
SIRIUS 3RQ1 force-guided coupling relays, fail-safe up to SIL 3/PL e

■ Overview
More information
Homepage, see www.siemens.com/sirius-coupling-relays
Industry Mall, see www.siemens.com/product?3RQ1
Technical specifications, see
https://support.industry.siemens.com/cs/ww/en/ps/26008/td
Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/26008/man
TIA Selection Tool Cloud (TST Cloud), see
www.siemens.com/tstcloud/?node=SIRIUSRelais
SIRIUS 3SK safety relays, see
https://mall.industry.siemens.com/mall/en/ww/Catalog/Products/
10143262?tree=CatalogTree

5
Video: SIRIUS 3RQ1 coupling relays
Picture on left: 3RQ1000-1EW00 coupling relay,
1 NO contact + 1 NC contact, screw terminal The force-guided SIRIUS 3RQ1 coupling relays in a modern
Picture on right: 3RQ1000-2LW00 coupling relay, titanium gray industrial enclosure are available in widths of
4 NO contacts + 1 NC contact, spring-loaded terminal (push-in)
17.5 mm and 22.5 mm, and each with a supply voltage
of 24 V DC (120 mm mounting depth) and 24 to 240 V AC/DC
(90 mm mounting depth).
They are used for safe coupling up to SIL 3/PL e of control
signals to and from a control system or as an output expansion
for the SIRIUS 3SK safety relays (see page 11/13 onwards).
Further fields of application are based on the force-guided
operation of relays according to IEC 60947-5-1 and EN 61810-3
for reading back relay states, for reliable diagnostics or signaling,
or for the use of antivalent signals. Typical fields of application
here are railways, signaling technology and elevators.
The series consists of devices with up to five outputs and can be
supplied with screw or spring-loaded (push-in) terminals.
International standards and certifications including CE, UL/CSA,
EAC and railway approvals ensure international usability and
exportability.
An extensive range of accessories is also available, such as
device connectors for easy and safe connection of the 3RQ1
3RQ1 coupling relay in the 3SK system devices, replacement terminals, push-in lugs for wall mounting
and coding pins, see page 5/27 onwards.

Siemens IC 10 · 2023 5/21


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ1 force-guided coupling relays, fail-safe up to SIL 3/PL e NEW NEU

Article number scheme


Product versions Article number
Coupling relays with force-guided contacts 3RQ1 @ 0 0 – @ @ @ 0 0
Version Performance Level (SIL): c (SIL 2) 0
Performance Level (SIL): e (SIL 3) 2
Connection methods Screw terminals 1
Spring-loaded terminals (push-in) 2
Outputs 1 NO + 1 NC E Width 17.5 mm
2 NO + 1 NC G Width 17.5 mm
2 NO + 2 NC H Width 22.5 mm
4 NO + 1 NC L Width 22.5 mm
Rated control supply voltage 24 V DC B Depth 120 mm
24 to 240 V AC/DC W Depth 90 mm
Example 3RQ1 0 0 0 – 1 E W 0 0
Note:
5

The article number scheme shows an overview of product versions For your orders, please use the article numbers quoted in the
for better understanding of the logic behind the article numbers. selection and ordering data.

■ Benefits
• Wide-range voltage versions from 24 to 240 V AC/DC
available with a mounting depth of 90 mm for all variants
• Permanent wiring thanks to removable terminals in screw
or spring-loaded technology (push-in)
• Replacement of individual terminals minimizes wiring effort
• Can be used as output extension for SIRIUS 3SK safety relays
via device connectors
• All versions with real load contacts, also in the NC circuit
• Safety certification according to functional safety SIL 3/PL e
• International standards and certifications including CE,
UL/CSA, EAC, railway approvals, and more

5/22 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
NEW NEU
SIRIUS 3RQ1 force-guided coupling relays, fail-safe up to SIL 3/PL e

■ Application
• Safe coupling up to SIL 3/PL e of control signals from and
to a control system
• Output expansion for 3SK safety relays
• Use of force-guided contacts for reading back relay states
• For reliable diagnostics or signaling or for antivalent switching
1 of loads
IC 01_0 06
92a • Safe coupling:
- Electrical separation between the input and output circuit
- Adjustment of different signal levels
2 - Signal amplification
2 2 2 3 - Contact multiplication
3RQ1 output expansion (up to SIL 3/PL e) for the 3SK system
The force-guided 3RQ1 coupling relays with a mounting depth
of 120 mm can be used as an output expansion up to SIL 3/PL e
and can be connected by wiring to all 3SK basic units and by

5
using the 3ZY12 device connector to all 3SK1 and 3SK2
Advanced basic units.
They have a switching capacity of AC-15 5/3 A (like 3SK1211)
at a switching voltage of 230 V and are available in widths of
17.5 mm and 22.5 mm. Furthermore, they have NC contacts with
8 a switching capacity of AC-15 2/1.5 A for direct switching of
7 loads (anti-parallel switching, signaling, etc.).
6
5
1 DIN rail 4

2 Device connector
3 Device termination connector
4 SIRIUS 3RM1 motor starter
5 Force-guided 3RQ1 coupling relay as output
expansion up to SIL 3/PL e
6 SIRIUS 3SK1211 output expansion
7 SIRIUS 3SK1121 Advanced basic unit
8 SIRIUS 3SK1220 sensor expansion

System configuration example with SIRIUS 3SK safety relays

Electronic
I/O control
devices 110 V AC 110 V AC Actuators
Output

230 V AC
Input

24 V DC 24 V DC 230 V AC
M

Pushbutton Coupling Coupling Motor


Position link NSB0_00186a link contactor
switch

Typical application with a fail-safe control system

Siemens IC 10 · 2023 5/23


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ1 force-guided coupling relays, fail-safe up to SIL 3/PL e NEW NEU

Applications

IC01_00741
IC01_00740
F-PLC

Controller 3RQ1 coupling relay


Input Output

3RQ1
coupling
relay
5

3RT2
contactor

Sensor Actuator
(e.g. SIDOOR) Motor Valve

Application based on force-guided operation 3RQ1 as coupling link for signals, e.g. for a fail-safe control system

3SK1 safety
relays 3RQ1 coupling
relays
IC01_00742

3RT2
contactors

Motor 1 Motor 2 Motor 3 Signaling


(SIL 3/PL e) (SIL 3/PL e) (SIL 1/PL c) column
via NC contact

3RQ1 as output expansion (SIL 1 to 3) for 3SK with direct control of


actuators and signaling elements

5/24 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
NEW NEU
SIRIUS 3RQ1 force-guided coupling relays, fail-safe up to SIL 3/PL e

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/26008/td https://support.industry.siemens.com/cs/ww/en/ps/26008/man
Equipment Manual 3SK1/3RQ1, see
https://support.industry.siemens.com/cs/ww/en/view/67585885

Article number 3RQ1000-.EB00, 3RQ1200-.EB00 3RQ1000-.EW00, 3RQ1200-.EW00 3RQ1000-.HB00, 3RQ1000-.HW00,


3RQ1000-.GB00 3RQ1000-.GW00 3RQ1000-.LB00 3RQ1000-.LW00
General data
Dimensions mm 17.5 x 100 x 120 17.5 x 100 x 90 22.5 x 100 x 120 22.5 x 100 x 90
(W x H x D)
H

5
Safety Integrity Level (SIL) 2 3 2 3 2
according to IEC 62061
Performance Level (PL) c e c e c
according to ISO 13849-1
Certificate of suitability
• UL approval Yes
• TÜV approval Yes
Insulation voltage for overvoltage V 300
category III according to IEC 60664 for
pollution degree 3
Ambient temperature
• During operation °C -25 ... +60
• During storage °C -40 ... +80
Degree of protection IP IP20
Control circuit
Control supply voltage
• At AC
- At 50 Hz V -- 24 ... 240 -- 24 ... 240
- At 60 Hz V -- 24 ... 240 -- 24 ... 240
• At DC V 24 24 ... 240 24 24 ... 240
Operating range factor of the control
supply voltage, rated value
• At DC 0.8 ... 1.2 0.7 ... 1.1 0.8 ... 1.2 0.7 ... 1.1
Load circuit
Thermal current of the non-solid-state A 5
contact blocks, maximum
Mechanical endurance (operating 10 000 000
cycles) typical

Article number 3RQ1000-1, 3RQ1200-1 3RQ1000-2, 3RQ1200-2


Type of electrical connection Screw terminals Spring-loaded terminals
(push-in)
Type of connectable conductor
cross-sections
• Solid 1x (0.5 ... 4.0 mm2), 2x (0.5 ... 2.5 mm2) 1x (0.5 ... 4 mm2)
• Finely stranded with end sleeve 1x (0.5 ... 4 mm2), 2x (0.5 ... 1.5 mm2) 1x (0.5 ... 2.5 mm2)
• Solid for AWG cables AWG 1x (20 ... 12), 2x (20 ... 14) 1x (20 ... 12)
Tightening torque Nm 0.6 ... 0.8 --

Siemens IC 10 · 2023 5/25


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ1 force-guided coupling relays, fail-safe up to SIL 3/PL e NEW NEU

■ Selection and ordering data


PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41H
Multi-unit packaging, Control supply voltage Number Depth Suitable for Screw terminals Spring-loaded terminals
see page 16/7. at AC at DC of use with (push-in)
at 50/60 Hz auxiliary 3ZY12
contacts device
connector
Article No. Price Article No. Price
V V NO NC mm per PU per PU
Width 17.5 mm
Fail-safe up to SIL 2/PL c
-- 24 1 1 120 ✓ 3RQ1000-1EB00 3RQ1000-2EB00
-- 24 2 1 120 ✓ 3RQ1000-1GB00 3RQ1000-2GB00
24 ... 240 24 ... 240 1 1 90 -- 3RQ1000-1EW00 3RQ1000-2EW00
24 ... 240 24 ... 240 2 1 90 -- 3RQ1000-1GW00 3RQ1000-2GW00
5

Fail-safe up to SIL 3/PL e


-- 24 1 --1) 120 ✓ 3RQ1200-1EB00 3RQ1200-2EB00
24 ... 240 24 ... 240 1 1 90 -- 3RQ1200-1EW00 3RQ1200-2EW00
3RQ1000- 3RQ1000-
1EW00 2EW00
Width 22.5 mm
Fail-safe up to SIL 2/PL c
-- 24 2 2 120 ✓ 3RQ1000-1HB00 3RQ1000-2HB00
-- 24 4 1 120 ✓ 3RQ1000-1LB00 3RQ1000-2LB00
24 ... 240 24 ... 240 2 2 90 -- 3RQ1000-1HW00 3RQ1000-2HW00
24 ... 240 24 ... 240 4 1 90 -- 3RQ1000-1LW00 3RQ1000-2LW00

3RQ1000- 3RQ1000-
1LW00 2LW00
✓ Yes Note:
-- No
1)
All force-guided 3RQ1 coupling relays have safety certification up
NC contact designed to act as feedback contact. to SIL 2/PL c or SIL 3/PL e according to IEC 62061/ISO 13849.
To achieve SIL 3/PL e, two 3RQ10 devices can also be wired in
series, see Equipment Manual.
In addition, the 3SK1211 devices (output expansions for 3SK)
provide force-guided coupling relays with 4 NO contacts and
1 NC contact up to SIL 3/PL e with 24 V AC, 24 V DC, and 110 to
240 V AC/DC.
For applications with high currents up to a switching capacity of
10 A AC-15, the 3SK1213 output expansions are also available
with 24 V AC, 24 V DC and 110 to 240 V AC/DC.
These devices can be used in the same way as the 3RQ1
coupling relays for coupling to and from safe control systems,
they feature 4 NO contacts and 1 NC contact, and are available
as variants with 24 V AC, 24 V DC and 110 to 240 V AC/DC (see
page 11/27).

* You can order this quantity or a multiple thereof.


5/26 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
NEW NEU
SIRIUS 3RQ1 force-guided coupling relays, fail-safe up to SIL 3/PL e

■ Accessories
More information
Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/26008/man

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Device connectors for the electrical connection of SIRIUS devices


in the industrial DIN-rail enclosure
Device connectors
• Width 17.5 mm (for 3RQ1000-.EB00/-.GB00, 3ZY1212-1BA00 1 1 unit 41L
3RQ1200-.EB00)
• Width 22.5 mm (for 3RQ1000-.HB00/-.LB00) 3ZY1212-2BA00 1 1 unit 41L

5
3ZY1212- 3ZY1212-
1BA00 2BA00
Device termination connectors
• Width 17.5 mm (for 3RQ1000-.EB00/-.GB00, 3ZY1212-1DA00 1 1 unit 41L
3RQ1200-.EB00)
• Width 22.5 mm (for 3RQ1000-.HB00/-.LB00) 3ZY1212-2DA00 1 1 unit 41L
Note:
Observe positions of the slide switch for width
22.5 mm, see Equipment Manual.

3ZY1212-
2DA00
Device daisy chain connectors 3ZY1212-2AB00 1 1 unit 41L
24 V DC, 22.5 mm, for implementation of distances
between devices according to the installation
guidelines
Device connectors 3ZY1210-2AA00 1 1 unit 41L
For height adjustment for device arrangements
without electrical connection via device connector,
with a width of 22.5 mm or greater
Terminals for SIRIUS devices in the industrial DIN-rail enclosure
Removable terminals Screw terminals

• 2-pole, up to 1 x 4 mm² or 2 x 2.5 mm² 3ZY1122-1BA00 1 6 units 41L


Spring-loaded terminals
(push-in)
3ZY1122- 3ZY1122- • 2-pole, up to 1 x 4 mm² or 2 x 1.5 mm² 3ZY1122-2BA00 1 6 units 41L
1BA00 2BA00 (in shared end sleeve)

Siemens IC 10 · 2023 5/27


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ1 force-guided coupling relays, fail-safe up to SIL 3/PL e NEW NEU

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Accessories for enclosures


Sealing covers
• 17.5 mm 3ZY1321-1AA00 1 5 units 41L
• 22.5 mm 3ZY1321-2AA00 1 5 units 41L

3ZY1321-2AA00
Push-in lugs 3ZY1311-0AA00 1 10 units 41L
For wall mounting
5

3ZY1311-0AA00
Coding pins 3ZY1440-1AA00 1 12 units 41L
For removable terminals of SIRIUS devices
in the industrial DIN-rail enclosure;
they enable the mechanical coding of terminals,
3ZY1440-1AA00 see Equipment Manual.
Hinged cover
Replacement cover, without terminal labeling, yellow
• 17.5 mm wide 3ZY1450-1BA00 1 5 units 41L
• 22.5 mm wide 3ZY1450-1BB00 1 5 units 41L

3ZY1450- 3ZY1450-
1BA00 1BB00
Blank labels
Unit labeling plates1)
For SIRIUS devices
• 17.5 mm: 10 mm x 7 mm, titanium gray 3RT2900-1SB10 100 816 units 41B
• 22.5 mm: 20 mm x 7 mm, titanium gray 3RT2900-1SB20 100 340 units 41B
IC01_00181

3RT2900-1SB20
Tools for opening spring-loaded terminals
Screwdriver Spring-loaded terminals
For all SIRIUS devices with spring-loaded terminals (push-in)
3.0 mm x 0.5 mm, 3RA2908-1A 1 1 unit 41B
length approx. 200 mm,
titanium gray/black,
3RA2908-1A partially insulated
1)
PC labeling system for individual inscription of
unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

5/28 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ2 coupling relays with industrial enclosure

■ Overview
More information
Homepage, see www.siemens.com/sirius-coupling-relays
Industry Mall, see www.siemens.com/product?3RQ2
TIA Selection Tool Cloud (TST Cloud), see
www.siemens.com/tstcloud/?node=SIRIUSRelais
Conversion tool, see www.siemens.com/conversion-tool
3RQ2 coupling relays in their 22.5 mm industrial enclosure serve
to couple control signals to and from a controller and replace
the 3RS18 coupling relays. The 3RQ2 has an impressively
high-quality industrial enclosure finished in modern titanium
gray so that it fits in visually with the SIRIUS series of relays.
The series consists of devices with up to three changeover
contacts with screw or spring-loaded terminals (push-in) and,
with its wide voltage range from 24 to 240 V AC/DC, is a genuine
highlight in the coupling relay market.

5
Thanks to terminal assignment that is identical to the previous
version, existing products can easily be converted.
SIRIUS 3RQ2 coupling relay, screw terminals, 3 changeover contacts
The reduced variety of components simplifies product selection
and standardization.
Numerous accessories are available for the 3RQ2 coupling
relays, for example replacement terminals, push-in lugs for wall
mounting and coding pins.
Article number scheme
Product versions Article number
Coupling relays, standard 3RQ2000 – @ @ @ 0 @
Connection methods Screw terminals 1
Spring-loaded terminals (push-in) 2
Outputs 1 CO contact A
2 CO contacts B
3 CO contacts C
Rated control supply voltage 24 ... 240 V AC/DC W
Material of switching contacts 0 = AgSnO2 0
1 = AgNi + Au 1
Example 3RQ2000 – 1 C W 0 1
Note:
The article number scheme shows an overview of product versions For your orders, please use the article numbers quoted
for better understanding of the logic behind the article numbers. in the selection and ordering data.

■ Benefits
• Permanent wiring thanks to removable terminals in screw • Reduced costs thanks to fewer versions
or spring-loaded technology (push-in) • Especially high contact reliability even at low currents thanks
• Replacement of individual terminals minimizes wiring effort to versions with hard gold-plated contacts
• A product for all voltages from 24 to 240 V AC/DC • International standards and certifications including CE,
UL/CSA, EAC, railway approvals, and more

■ Application
• Electrical separation between the input and output circuit • Signal amplification
• Adjustment of different signal levels • Contact multiplication

Electronic
I/O control
devices 110 V AC 110 V AC Actuators
Output

230 V AC
Input

24 V DC 24 V DC 230 V AC
M

Pushbutton Coupling Coupling Motor


Position link NSB0_00186a link contactor
switch

Application example motor controller

Siemens IC 10 · 2023 5/29


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ2 coupling relays with industrial enclosure

■ Technical specifications
More information
Technical specifications, see Operating Instructions, see
https://support.industry.siemens.com/cs/ww/en/ps/25158/td https://support.industry.siemens.com/cs/ww/en/ps/25158/man

Article number 3RQ2000-.AW00 3RQ2000-.CW01


3RQ2000-.BW00
3RQ2000-.CW00
General data
Width x height x depth mm 22.5 x 100 x 90

D
W

Insulation voltage for overvoltage category III V 300


according to IEC 60664 for pollution degree 3
5

Max. permissible voltage for protective separation V 300


between control circuit and auxiliary circuit according
to IEC 60947-1
Ambient temperature
• During operation °C -40 ... +60
• During storage °C -40 ... +80
Degree of protection IP IP20
Control circuit
Control supply voltage V 24 ... 240 AC/DC; 50/60 Hz
Operating range factor of control supply voltage 0.7 ... 1.1
Load circuit
Thermal current of the non-solid-state contact blocks, maximum A 5
Current-carrying capacity of the output relay
• At AC-15 at 250 V A 3
• At DC-13 at 24 V A 1
• At DC-13 at 125 V A 0.2
• At DC-13 at 250 V A 0.1
Mechanical endurance (operating cycles) typical 10 000 000
Electrical endurance (operating cycles) for AC-15 at 230 V, typical 100 000
Material of switching contacts AgSnO2 AgNi + Au

Article number 3RQ2000-1 3RQ2000-2


Type of electrical connection Screw terminals Spring-loaded terminals
(push-in)
Type of connectable conductor cross-sections
• Solid 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) 1x (0.5 ... 4 mm²)
• Finely stranded with end sleeve 1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²) 1x (0.5 ... 2.5 mm²)
• Solid for AWG cables 1x (20 ... 12), 2x (20 ... 14) 1x (20 ... 12)
Tightening torque Nm 0.6 ... 0.8 --

5/30 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ2 coupling relays with industrial enclosure

■ Selection and ordering data


PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41H
Multi-unit packaging, Control supply voltage Number of Material of Screw terminals Spring-loaded terminals
see page 16/7. at AC at DC CO contacts switching (push-in)
at 50 Hz for auxiliary contacts
contacts
Article No. Price Article No. Price
V V W per PU per PU
Coupling relays with industrial enclosure, 22.5 mm
24 ... 240 24 ... 240 1 AgSnO2 3RQ2000-1AW00 3RQ2000-2AW00
2 AgSnO2 3RQ2000-1BW00 3RQ2000-2BW00
3 AgSnO2 3RQ2000-1CW00 3RQ2000-2CW00
3 AgNi + Au 3RQ2000-1CW01 3RQ2000-2CW01

5
3RQ2000- 3RQ2000-
1CW00 2CW00

■ Accessories
More information
Operating Instructions, see Conversion tool, see www.siemens.com/conversion-tool
https://support.industry.siemens.com/cs/ww/en/ps/25158/man

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Terminals for SIRIUS devices in the industrial DIN-rail enclosure


Removable terminals Screw terminals

• 2-pole, up to 1 x 4 mm² or 2 x 2.5 mm² 3ZY1122-1BA00 1 6 units 41L


Spring-loaded terminals
(push-in)
3ZY1122-1BA00 • 2-pole, up to 1 x 4 mm² or 2 x 1.5 mm² 3ZY1122-2BA00 1 6 units 41L
(in shared end sleeve)
Accessories for enclosures
Hinged cover 3ZY1450-1AB00 1 5 units 41L
Replacement cover, without terminal labeling,
titanium gray, 22.5 mm wide

3ZY1450-1AB00
Push-in lugs 3ZY1311-0AA00 1 10 units 41L
For wall mounting

3ZY1311-0AA00
Coding pins 3ZY1440-1AA00 1 12 units 41L
For removable terminals of SIRIUS devices
in the industrial DIN-rail enclosure;
3ZY1440-1AA00 they enable the mechanical coding of terminals
Blank labels
Unit labeling plates 3RT2900-1SB20 100 340 units 41B
For SIRIUS devices
20 mm x 7 mm, titanium gray1)
IC01_00181

3RT2900-1SB20
Tools for opening spring-loaded terminals
Screwdriver Spring-loaded terminals
For all SIRIUS devices with spring-loaded terminals (push-in)
3.0 mm x 0.5 mm, length approx. 200 mm, 3RA2908-1A 1 1 unit 41B
titanium gray/black, partially insulated
3RA2908-1A
1) PC labeling system for individual inscription of murrplastik Systemtechnik GmbH
unit labeling plates available from: (see page 16/18).
* You can order this quantity or a multiple thereof.
Illustrations are approximate Siemens IC 10 · 2023 5/31
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ2 coupling relays with industrial enclosure

■ More information
Code conversion table
SIRIUS 3RS18 coupling relays Comparison type SIRIUS 3RQ2 coupling relays
Screw terminals Spring-loaded Version Contacts Screw terminals Spring-loaded Version Contacts
terminals terminals
(push-in)
3RS1800-1AQ00 3RS1800-2AQ00 24 V AC/DC; 110 ... 120 V AC 1 CO 3RQ2000-1AW00 3RQ2000-2AW00 24 ... 240 V AC/DC 1 CO
3RS1800-1AP00 3RS1800-2AP00 24 V AC/DC; 220 ... 240 V AC contact contact
3RS1800-1BW00 3RS1800-2BW00 24 ... 240 V AC/DC 2 CO 3RQ2000-1BW00 3RQ2000-2BW00 24 ... 240 V AC/DC 2 CO
3RS1800-1BQ00 3RS1800-2BQ00 24 V AC/DC; 110 ... 120 V AC contacts contacts
3RS1800-1BP00 3RS1800-2BP00 24 V AC/DC; 220 ... 240 V AC
3RS1800-1HW00 3RS1800-2HW00 24 ... 240 V AC/DC 3 CO 3RQ2000-1CW00 3RQ2000-2CW00 24 ... 240 V AC/DC 3 CO
3RS1800-1HQ00 3RS1800-2HQ00 24 V AC/DC; 110 ... 120 V AC contacts contacts
3RS1800-1HP00 3RS1800-2HP00 24 V AC/DC; 220 ... 240 V AC
3RS1800-1HW01 3RS1800-2HW01 24 ... 240 V AC/DC 3 CO 3RQ2000-1CW01 3RQ2000-2CW01 24 ... 240 V AC/DC 3 CO
24 V AC/DC; 110 ... 120 V AC contacts, contacts,
5

3RS1800-1HQ01 3RS1800-2HQ01
hard gold- hard gold-
3RS1800-1HP01 3RS1800-2HP01 24 V AC/DC; 220 ... 240 V AC plated plated

5/32 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ3 coupling relays, narrow design

■ Overview
Coupling relays with relay output (not plug-in)
AC and DC operation
IEC 60947-5-1
The input and output coupling relays differ with regard to the
positioning of the terminals and the LEDs.
Coupling relays with plug-in relays
AC and DC operation
IEC 60947-1
The coupling relays are plug-in, so the relay can be replaced
quickly at the end of its service life without detaching the wiring.
Coupling relays with semiconductor output (not plug-in)
AC and DC operation

5
IEC 60947-1, EN 60664-1 and EN 50005;
coupling relays with semiconductor output: EN 60747-5;
SIRIUS 3RQ3 coupling relays programmable logic controllers: IEC 61131-2
More information The input and output coupling relays differ with regard to the
Homepage, see www.siemens.com/sirius-coupling-relays positioning of the terminals and the LEDs.
Industry Mall, see www.siemens.com/product?3RQ3 The coupling relays with semiconductor output have extremely
TIA Selection Tool Cloud (TST Cloud), see high contact reliability, so they are especially suitable for
www.siemens.com/tstcloud/?node=SIRIUSRelais solid-state systems.
Conversion tool, see www.siemens.com/conversion-tool
For test purposes, versions are available with manual-off-
SIRIUS 3RQ3 coupling relays in narrow design are used for automatic switches.
coupling control signals from and to a controller, and they are
available in different versions:
• Coupling relays with relay output (not plug-in)
• Coupling relays with plug-in relays
• Coupling relays with semiconductor output (not plug-in)

Siemens IC 10 · 2023 5/33


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ3 coupling relays, narrow design
Article number schemes
Product versions Article number
Coupling relays with relay output (not plug-in) 3RQ30 @ 8 – @ A @ 0 @
Design and type of output Output coupler, without manual-off-automatic 1
switch
Input coupler 3
Type of electrical connection Screw terminals 1
Spring-loaded terminals (push-in) 2
Control supply voltage 24 V AC/DC B
115 V AC/DC E
230 V AC/DC F
Material of switching e.g.
contacts 0 = AgSnO2 @
1 = AgSnO2 hard gold-plated @
Example 3RQ30 1 8 – 1 A B 0 1
5

Product versions Article number


Coupling relays with relay output (not plug-in) 3RQ30 1 8 – 2 A @ 0 8 – 0 A @ 0
Railway version with extended operating range 0.7 ... 1.2 x Us
Control supply voltage 24 V DC M
110 V DC N
Standard printed circuit A
board
Protective coating on printed circuit board X
Example 3RQ30 1 8 – 2 A M 0 8 – 0 A A 0

Product versions Article number


Coupling relays with plug-in relays 3RQ31 1 8 – @ A @ 0 @
Type of electrical connection Screw terminals 1
Spring-loaded terminals (push-in) 2
Control supply voltage 24 V AC/DC B
115 V AC/DC E
230 V AC/DC F
24 V DC M
Material of switching AgSnO2 0
contacts AgSnO2 hard gold-plated 1
Example 3RQ31 1 8 – 1 A B 0 1

Product versions Article number


Coupling relays with semiconductor output (not plug-in) 3RQ30 @ @ – @ S @ @ 0
Current-carrying capacity of the semiconductor Control supply Switching voltage of
output voltage the semiconductor
output
Output coupler
• Without manual-off- 1 mA ... 0.5 A 5 0 @ M5 11 ... 30 V DC 10 ... 60 V DC
automatic switch 5 mA ... 2 A 5 2 @ M3 11 ... 30 V DC 10 ... 30 V DC
1 mA ... 2 A 5 2 @ M4 11 ... 30 V DC 10 ... 60 V DC
5 mA ... 2 A 5 2 @ M5 11 ... 30 V DC 20 ... 264 V AC
1 mA ... 3 A 5 3 @ G 3 110 ... 230 V AC/DC 10 ... 30 V DC
5 mA ... 5 A 5 5 @ M3 11 ... 30 V DC 10 ... 30 V DC
• With manual-off-automatic 5 mA ... 5 A 6 5 @ M3 11 ... 30 V DC 10 ... 30 V DC
switch
Input coupler 10 mA ... 0.5 A 7 0 @ B 3 11 ... 30 V AC/DC 10 ... 30 V DC
7 0 @ G 3 110 ... 230 V AC/DC 10 ... 30 V DC
Type of electrical connection Screw terminals 1
Spring-loaded terminals (push-in) 2
Example 3RQ30 7 0 – 1 S B 3 0
Note:
The article number schemes show an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the selection and ordering data.
article numbers.

5/34 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ3 coupling relays, narrow design

■ Benefits
General Coupling relays with relay output (not plug-in)
• All versions with screw terminals or spring-loaded terminals • Relays fixed in enclosure for increased contact reliability
(push-in technology) • Device variants with hard gold-plated contacts, hence high
• TOP wiring with spring-loaded terminals (push-in) for quick contact reliability at low currents
and reliable wiring
Coupling relays with plug-in relays
• Low space requirements in the control cabinet thanks to a
consistent width of 6.2 mm • Fast replacement of the relays with existing wiring
• Reduced stock-keeping due to fewer variants • Shorter installation times thanks to certified complete units
• Clearly visible functional state of the coupling relay by green • Individual relays available as spare parts
LED • Device variants with hard gold-plated contacts, hence high
• Integrated reverse polarity protection and EMC suppressor contact reliability at low currents
diode Coupling relays with semiconductor output (not plug-in)
• Standardized accessories across the entire 3RQ3 series • Long service life since there is no mechanical wear
• Universal bridging option using connecting combs for all • High switching frequency thanks to short make-break times

5
terminals
• Vibration-resistant
• Galvanic isolation plate for isolating different voltages for
neighboring units • No contact bounce
• Clip-on labels available as set for individual labeling • Extremely high contact reliability
• Noise-free switching
• Low control power required
• Switching of DC and capacitive loads
Note:
With semiconductors, the switching current is not dependent
on the inductance of the load, i.e. the switching current for an
inductive DC-13 load is the same as that for a DC-12 load.
This means that coupling links with a semiconductor output are
particularly suitable for inductive loads such as solenoid valves.
It is not relevant to specify the number of operating cycles,
because this does not affect the endurance of the semiconductor,
provided it is not overheated.

■ Application
• Electrical separation between the input and output circuit
• Adjustment of different signal levels
• Signal amplification

Electronic
I/O control
devices 110 V AC 110 V AC Actuators
Output

230 V AC
Input

24 V DC 24 V DC 230 V AC
M

Pushbutton Coupling Coupling Motor


Position link NSB0_00186a link contactor
switch

Application example motor controller

Siemens IC 10 · 2023 5/35


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ3 coupling relays, narrow design

■ Technical specifications
More information
Technical specifications, see Operating Instructions, see
https://support.industry.siemens.com/cs/ww/en/ps/16198/td https://support.industry.siemens.com/cs/ww/en/ps/16198/man
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16198/faq

Coupling relays with relay output (not plug-in)


Article number 3RQ30.8- 3RQ30.8- 3RQ30.8- 3RQ30.8- 3RQ30.8- 3RQ30.8- 3RQ3018- 3RQ3018-
.AB00 .AB01 .AE00 .AE01 .AF00 .AF01 2AM08-0A.0 2AN08-0A.0
General technical specifications
Width x height x depth mm 6.2 x 93 x 72.5
H

Insulation voltage for overvoltage category III V 300


5

according to IEC 60664 for pollution degree 3


Max. permissible voltage for protective separation V 300
between control circuit and auxiliary circuit
Ambient temperature
• During operation °C -25 ... +60 -40 ... +70
• During storage °C -40 ... +85
Degree of protection IP IP20
Version of the fuse link required for short-circuit Fuse gG: 4 A
protection of the auxiliary switch
Operational current of the auxiliary contacts
• At AC-15
- At 24 V A 3
- At 250 V A 3
• At DC-13
- At 24 V A 1
- At 125 V A 0.2
- At 250 V A 0.1
Contact reliability of the auxiliary contacts 17 V, 5 V, 17 V, 5 V, 17 V, 5 V, 17 V,
(one contact failure per 100 million) 5 mA 1 mA 5 mA 1 mA 5 mA 1 mA 5 mA
Mechanical endurance (operating cycles) typical 10 000 000
Electrical endurance (operating cycles) for AC-15 100 000
at 250 V typical
Operating range factor of the control supply
voltage, rated value
• At AC
- At 50 Hz 0.8 ... 1.25 0.8 ... 1.1 --
- At 60 Hz 0.8 ... 1.25 0.8 ... 1.1 --
• At DC 0.8 ... 1.25 0.8 ... 1.1 0.7 ... 1.25
Active power input W 0.3 0.5 1 0.3 0.6
Thermal current A 6
• Note -- Derating, see
characteristic curves

5/36 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ3 coupling relays, narrow design
Coupling relays with plug-in relays
Article number 3RQ3118- 3RQ3118- 3RQ3118- 3RQ3118- 3RQ3118- 3RQ3118- 3RQ3118- 3RQ3118-
.AB00 .AB01 .AE00 .AE01 .AF00 .AF01 .AM00 .AM01
General technical specifications
Width x height x depth mm 6.2 x 93 x 76

D
W

Insulation voltage for overvoltage category III V 300


according to IEC 60664 for pollution degree 3
Max. permissible voltage for protective separation V 300
between control circuit and auxiliary circuit
Ambient temperature
• During operation °C -25 ... +60
• During storage °C -40 ... +85
Degree of protection IP IP20

5
Version of the fuse link required for short-circuit Fuse gG: 4 A
protection of the auxiliary switch
Operational current of the auxiliary contacts
• At AC-15
- At 24 V A 3
- At 250 V A 3
• At DC-13
- At 24 V A 1
- At 125 V A 0.2
- At 250 V A 0.1
Contact reliability of the auxiliary contacts 17 V, 5 V, 17 V, 5 V, 17 V, 5 V, 17 V, 5 V,
(one contact failure per 100 million) 5 mA 1 mA 5 mA 1 mA 5 mA 1 mA 5 mA 1 mA
Mechanical endurance (operating cycles) typical 10 000 000
Electrical endurance (operating cycles) for AC-15 100 000
at 250 V typical
Operating range factor of the control supply
voltage, rated value
• At AC
- At 50 Hz 0.8 ... 1.25 0.8 ... 1.1 --
- At 60 Hz 0.8 ... 1.25 0.8 ... 1.1 --
• At DC 0.8 ... 1.25 0.8 ... 1.1 0.8 ... 1.25
Active power input W 0.3 0.5 1 0.3
Thermal current A 6

Siemens IC 10 · 2023 5/37


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ3 coupling relays, narrow design
Coupling relays with semiconductor output (not plug-in)
Article number 3RQ3050- 3RQ3052- 3RQ3052- 3RQ3052- 3RQ3053- 3RQ3055- 3RQ3065- 3RQ3070- 3RQ3070-
.SM50 .SM30 .SM40 .SM50 .SG30 .SM30 .SM30 .SB30 .SG30
General technical specifications
Width x height x mm 6.2 x 93 x 72.5 6.2 x 93 x 6.2 x 93 x 72.5
depth 75
H

Insulation voltage for overvoltage V 50 300 50 --


category III according
to IEC 60664 for pollution degree 3
Ambient temperature
• During operation °C -25 ... +60
• During storage °C -40 ... +85
Degree of protection IP IP20
Switching voltage of the
5

semiconductor output
• At AC V -- 20 ... 264 --
• At DC V 10 ... 60 10 ... 30 10 ... 60 -- 10 ... 30
Current-carrying capacity of the
semiconductor output
• At AC -- 5 mA ... 2 A --
• At DC 1 mA ... 0.5 A 5 mA ... 2 A 1 mA ... 2 A -- 1 mA ... 3 A 5 mA ... 5 A 10 mA ... 0.5 A
Operating range factor of the
control supply voltage, rated value
• At AC
- At 50 Hz -- 0.7 ... 1.1 -- 1 ... 1 0.7 ... 1.1
- At 60 Hz -- 0.7 ... 1.1 -- 1 ... 1 0.7 ... 1.1
• At DC 1 ... 1 0.7 ... 1.1 1 ... 1 0.7 ... 1.1
Active power input W 0.3 0.25 0.3 0.5
Thermal current A 0.5 2 3 5 0.5

Article number 3RQ3...-1.... 3RQ3...-2....


Type of electrical connection for Screw terminals Spring-loaded terminals (push-in)
auxiliary and control circuits
Type of connectable conductor
cross-sections
• Solid 1x (0.25 ... 2.5 mm2)
• Finely stranded
- Without end sleeves -- 1x (0.25 ... 2.5 mm2)
2
- With end sleeves 1x (0.25 ... 1.5 mm )
• Solid for AWG cables 1x (20 ... 14)

5/38 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ3 coupling relays, narrow design

■ Selection and ordering data


Type of Control supply voltage Number Material of Protective Article No. Price PU PS* PG
voltage at AC at DC of CO switching coating per PU (UNIT,
contacts contacts on printed SET, M)
at at for auxiliary circuit
50 Hz 60 Hz contacts board
V V V
Coupling relays with relay output (not plug-in)
Output coupling links
AC/DC 24 24 24 1 AgSnO2 -- 3RQ3018-@AB00 1 5 units 41H
AgSnO2 -- 3RQ3018-@AB01 1 5 units 41H
Hard gold-
plated
115 115 115 1 AgSnO2 -- 3RQ3018-@AE00 1 5 units 41H
230 230 230 1 AgSnO2 -- 3RQ3018-@AF00 1 5 units 41H
DC -- -- 24 1 AgSnO2 -- 3RQ3018-2AM08-0AA0 1 5 units 41H
AgSnO2 Yes NEW NEU
3RQ3018-2AM08-0AX0
3RQ30.8-

5
2.... 110 1 AgSnO2 -- 3RQ3018-2AN08-0AA0 1 5 units 41H
AgSnO2 Yes NEW NEU
3RQ3018-2AN08-0AX0
Input coupling links
AC/DC 24 24 24 1 AgSnO2 -- 3RQ3038-@AB00 1 5 units 41H
AgSnO2 -- 3RQ3038-@AB01 1 5 units 41H
Hard gold-
plated
115 115 115 1 AgSnO2 -- 3RQ3038-@AE00 1 5 units 41H
AgSnO2 -- 3RQ3038-@AE01 1 5 units 41H
Hard gold-
plated
230 230 230 1 AgSnO2 -- 3RQ3038-@AF00 1 5 units 41H
AgSnO2 -- 3RQ3038-@AF01 1 5 units 41H
Hard gold-
plated
Coupling relays with plug-in relays
Output coupling links
AC/DC 24 24 24 1 AgSnO2 -- 3RQ3118-@AB00 1 5 units 41H
AgSnO2 -- 3RQ3118-@AB01 1 5 units 41H
Hard gold-
plated
115 115 115 1 AgSnO2 -- 3RQ3118-@AE00 1 5 units 41H
AgSnO2 -- 3RQ3118-@AE01 1 5 units 41H
Hard gold-
plated
3RQ3118- 230 230 230 1 AgSnO2 -- 3RQ3118-@AF00 1 5 units 41H
2....
AgSnO2 -- 3RQ3118-@AF01 1 5 units 41H
Hard gold-
plated
DC -- -- 24 1 AgSnO2 -- 3RQ3118-@AM00 1 5 units 41H
AgSnO2 -- 3RQ3118-@AM01 1 5 units 41H
Hard gold-
plated
Type of electrical connection
• Screw terminals 1
• Spring-loaded terminals (push-in) 2

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 5/39
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ3 coupling relays, narrow design

Type of Control supply voltage Current-carrying capacity Operating Article No. Price PU PS* PG
voltage of the semiconductor mode per PU (UNIT,
output selectable SET, M)
at AC at DC at AC at DC via switch
position
at at
50 Hz 60 Hz

Coupling relays with semiconductor output (not plug-in)


Output coupling links
DC -- -- 11 ... -- 1 mA ... 0.5 A -- 3RQ3050-@SM50 1 5 units 41H
30 V 5 mA ... 2 A -- 3RQ3052-@SM30 1 5 units 41H
1 mA ... 2 A -- 3RQ3052-@SM40 1 5 units 41H
5 mA ... 2 A -- -- 3RQ3052-@SM50 1 5 units 41H
-- 5 mA ... 5 A -- 3RQ3055-@SM30 1 5 units 41H
Manual/ 3RQ3065-@SM30 1 5 units 41H
Off/
Automatic
3RQ3050-
5

2SM50 AC/DC 110 ... 110 ... 110 ... -- 1 mA ... 3 A -- 3RQ3053-@SG30 1 5 units 41H
230 V 230 V 230 V
Input coupling links
AC/DC 11 ... 11 ... 11 ... -- 10 mA ... -- 3RQ3070-@SB30 1 5 units 41H
30 V 30 V 30 V 0.5 A
110 ... 110 ... 110 ... -- 10 mA ... -- 3RQ3070-@SG30 1 5 units 41H
230 V 230 V 230 V 0.5 A
Type of electrical connection
• Screw terminals 1
• Spring-loaded terminals (push-in) 2

* You can order this quantity or a multiple thereof.


5/40 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
SIRIUS 3RQ3 coupling relays, narrow design

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Galvanic isolation plates


For electrical separation of different potentials when devices 3RQ3900-0A 1 10 units 41H
of different types are installed side by side

3RQ3900-0A
Connecting combs
For linking the same potentials,
current carrying capacity for infeed max. 6 A

5
• 2-pole 3RQ3901-0A 1 10 units 41H
3RQ3901-0B
• 4-pole 3RQ3901-0B 1 10 units 41H
• 8-pole 3RQ3901-0C 1 10 units 41H
• 16-pole 3RQ3901-0D 1 10 units 41H
Clip-on labels1)
For terminal and equipment labeling, white
• 5 x 5 mm 3RQ3902-0A 100 2000 units 41H
• 6 x 12 mm (for 3RQ31 only) 3RQ3902-0B 100 1200 units 41H
3RQ3902-0A
Tools for opening spring-loaded terminals
Screwdriver Spring-loaded terminals
For all SIRIUS devices with spring-loaded terminals (push-in)
3.0 mm x 0.5 mm, 3RA2908-1A 1 1 unit 41B
length approx. 200 mm,
titanium gray/black,
3RA2908-1A partially insulated
1) PC labeling system for individual inscription of unit labeling
plates available from:
Conta-Clip Verbindungstechnik GmbH
(see page 16/18).

Coupling relays Control Material of switching Number Article No. Price PU PS* PG
with plug-in supply contacts of CO per PU (UNIT,
relays voltage contacts SET, M)
for
auxiliary
contacts
Type V
Replacement modules for 3RQ3118 coupling relays with plug-in relays
3RQ3118-.AM00 24 DC AgSnO2 1 3TX7014-7BM00 1 15 units 41H
3RQ3118-.AM01 AgSnO2 3TX7014-7BM02 1 15 units 41H
Hard gold-plated
3RQ3118-.AB00 24 AC/DC AgSnO2 1 3TX7014-7BM00 1 15 units 41H
3RQ3118-.AB01 AgSnO2 3TX7014-7BM02 1 15 units 41H
Hard gold-plated
3RQ3118-.AE00 115 AC/DC AgSnO2 1 3TX7014-7BP00 1 20 units 41H
3RQ3118-.AF00 230 AC/DC AgSnO2
3RQ3118-.AE01 115 AC/DC AgSnO2 1 3TX7014-7BP02 1 20 units 41H
Hard gold-plated
3RQ3118-.AF01 230 AC/DC AgSnO2
Hard gold-plated

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 5/41
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
LZS coupling relays with plug-in relays

■ Overview
Logical separation
More information
Homepage, see www.siemens.com/sirius-coupling-relays The terminals for the contacts and the terminals for the coil are
arranged on separate levels, e.g. above for contacts and below
Industry Mall, see www.siemens.com/product?3RQ_3RS_LZ
for coil. Logical separation is not necessarily protective
TIA Selection Tool Cloud (TST Cloud), see separation.
www.siemens.com/tstcloud/?node=SIRIUSRelais
LZS coupling relays with plug-in relays can be ordered as Protective separation
complete units or as individual modules for customer assembly. For protective separation, transfer of the voltage of one circuit to
another circuit is prevented to a suitable degree of safety
Function
(requirements and tests are described in IEC 60947-1 in Annex N).
The coupling relays with semiconductor output have low power
consumption and are therefore particularly well-suited to solid- Notes on the previous LZX series
state systems. In the versions equipped with LEDs, these The lower-cost complete units of the LZS series are fully
indicate the switching state. The LZS:PT/MT coupling relays compatible with the corresponding complete units of the
have a test button. This can be used to force the relays into the previous LZX series.
switching state and to lock it without electrical control. This is
indicated by a raised petrol-colored lever. The LZX plug-in relays are available unchanged and are used
5

accordingly in both the LZS and the LZX series.


Control with solid-state output
Note:
In the case of solid-state outputs (e.g. proximity switch) with
overload and short-circuit protection, you must make allowance Due to differences in geometry, the LED modules, plug-in
during configuration for the temporarily flowing capacitor sockets, fixing brackets and labels can be combined and/or
charging currents! This is possible, for example, by using used only in the respective series, LZS or LZX.
a suitable LZS coupling relay with plug-in relay. The LZS series offers not only service-proven screw connections
but also versions with plug-in terminals (push-in).
Surge suppression
The 24 V DC relays LZX:RT and LZX:PT with LEDs can be
supplied with, all others without integral surge suppression
(freewheeling diode connected in parallel with A1/A2). The
positive control supply voltage must be connected to coil
terminal A1.
Mounting
The relays are plugged into the base and this is snapped onto
a TH 35 DIN rail according to IEC 60715.
A fixing bracket can be ordered for the MT series that
additionally fixes the relay into a plug-in socket (under
conditions of increased mechanical stress). For the RT and
PT series, a combined fixing and ejection bracket is available
which can be used to disassemble the relays when they are
mounted side-by-side.
They can be mounted as required.

5/42 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
LZS coupling relays with plug-in relays

■ Technical specifications
More information
Technical specifications, see Manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/16204/td https://support.industry.siemens.com/cs/ww/en/ps/16204/man

Relay type LZX:RT print relay, 8-pole, LZX:PT industrial relay, 8-, 11- and 14-pole,
(12.7 mm) 1 CO/2 CO (22.5 mm) 2 CO/3 CO/4 CO
General data
Dimensions (W x H x D)
• LZS:RT.A4/LZS:PT.A5 mm 15.5 x 78 x 71 28 x 74 x 72
H

• LZS:RT.B4/LZS:PT.B5 mm 15.5 x 77 x 71 28 x 77 x 79
• LZS:RT.D4/LZS:PT.D5 mm 15.5 x 98 x 71 28 x 98 x 79
D

Rated control supply voltage Us1) V 24 24 AC 115 AC 230 AC 24 DC 24 AC 115 AC 230 AC


DC
Rated insulation voltage Ui V 250

5
(Pollution degree 3)
Overvoltage category III
According to IEC 60664-1
Protective separation Up to 250 V (with plug-in socket LZS:RT78726) No
Between coil and contacts No (for complete units with standard socket)
According to IEC 60947-1, Annex N
Degree of protection
• Relays IP67 IP50
• Bases IP20
Permissible ambient temperature
• During operation °C -40 ... +70
• During storage °C -40 ... +80
Conductor cross-sections
Connection type Screw terminals

• Solid mm2 2 x 2.5


• Finely stranded with end sleeve mm2 2 x 1.5
• Corresponding opening tool Screwdriver, size 3.0 ... 3.5 mm x 0.5 mm (3RA2908-1A)
Connection type Plug-in terminals (push-in)

• Solid mm2 1 x (0.75 ... 1.5), 2 x (0.75 ... 1.0), 2 x 1.5


• Finely stranded without end sleeve mm2 1 x (0.75 ... 1.5), 2 x (0.75 ... 1.0), 2 x 1.5
• Finely stranded with end sleeve mm2 1 x (0.75 ... 1.0), 2 x 0.75, 1 x 1.5
1) AC voltages, 50 Hz; for 60 Hz operation, the lower response value must be
increased by 10%; the power loss will decrease slightly.

Siemens IC 10 · 2023 5/43


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
LZS coupling relays with plug-in relays

Relay type LZX:RT print relay, 8-pole, LZX:PT industrial relay, 8-, 11- and 14-pole,
(12.7 mm) 1 CO/2 CO (22.5 mm) 2 CO/3 CO/4 CO
Rated control supply voltage Us1) V 24 DC 24 AC 115 AC 230 AC 24 DC 24 AC 115 AC 230 AC
Control side
Operating range factor 0.9 ... 1.4 0.9 ... 1.1 0.9 ... 1.4 0.9 ... 1.1
Power consumption at Us
• AC VA -- 0.75 -- 1
• DC W 0.4 -- 0.75 --
Release voltage V 2.4 3.6 17.3 34.5 2.4 7.2 34.5 69
Protection circuit Freewheel- -- Freewheel- --
ing diode ing diode
for com- in LED
plete unit module
Load side
Switching voltage
AC/DC V 24 ... 250
Rated currents2)
5

• Conventional thermal current Ith


- 1 CO contact A 16 --
- 2 CO contacts A 8 12
- 3 CO contacts A -- 10
- 4 CO contacts A -- 6
• Rated operational current Ie/AC-15
according to utilization categories
(IEC 60947-5-1)
- 1 CO contact A 6 3 4 2
- 2 CO contacts A 3 4 2
- 3 CO contacts A -- 4 2
- 4 CO contacts A -- 4 2
• Rated operational current Ie/DC-13 with A 2 at 24 V, PT2, PT3, PT5:
suppressor diode according to utilization 0.27 at 230 V 4 at 24 V,
categories (IEC 60947-5-1) 0.5 at 230 V
Short-circuit protection
Short-circuit test with fuse links
of operational class gG
with short-circuit current Ik = 1 kA
according to IEC 60947-5-1
• DIAZED, type 5SB A 10 6
Min. contact load Standard 17 V, 10 mA; Standard 17 V, 10 mA;
(reliability: 1 ppm) hard gold-plated 17 V/0.1 mA hard gold-plated 20 V/1 mA
Mechanical endurance
• 1 CO contact Oper- 30 x 106 10 x 106 1 x 105 7 x 104 30 x 106 20 x 106
ating
cycles
• 2 CO contacts Oper- 30 x 106 5 x 106 1 x 105 8 x 104 30 x 106 20 x 106
ating
cycles
• 3 CO contacts Oper- -- 30 x 106 20 x 106
ating
cycles
• 4 CO contacts Oper- -- 30 x 106 20 x 106
ating
cycles
Electrical endurance
(resistive load at 250 V AC)
• 1 CO contact Oper- 1 x 105 7 x 104 --
ating
cycles
• 2 CO contacts Oper- 1 x 105 8 x 104 180 x 103
ating
cycles
• 3 CO contacts Oper- -- 180 x 103
ating
cycles
• 4 CO contacts Oper- -- 250 x 103
ating
cycles
1)
AC voltages, 50 Hz; for 60 Hz operation, the lower response value must be
increased by 10%; the power loss will decrease slightly.
2)
Capacitive loads can result in micro-welding on the contacts.

5/44 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
LZS coupling relays with plug-in relays

Relay type LZS industrial relay: MT, 11-pole


(35.5 mm) 3 CO contacts
General data
Dimensions (W x H x D) mm 36 x 69 x 36

D
W

Rated control supply voltage Us1) V 24 DC 24 AC 115 AC 230 AC


Rated insulation voltage Ui V 250
(Pollution degree 3)
Overvoltage category III
According to IEC 60664-1
Protective separation No
Between coil and contacts
According to IEC 60947-1, Annex N
Degree of protection of relays/bases
• Relays IP50

5
• Bases IP20
Permissible ambient temperature
• During operation °C -40 ... +60 -45 ... +50
• During storage °C -45 ... +80
Conductor cross-sections
Connection type Screw terminals

• Solid mm2 2 x 2.5


• Finely stranded with or without end sleeve mm2 2 x 1.5
• Corresponding opening tool Screwdriver, size 1 or Pozidriv 1
Control side
Operating range V 18 ... 38 19.2 ... 38 92 ... 137 184 ... 264
Power consumption
• AC VA -- 2.3
• DC W 1.2 --
Release voltage V 2.4 9.6 46 92
Protection circuit --
Load side
Switching voltage
• AC/DC V 24 ... 250
Rated currents2)
• Conventional thermal current Ith A 10
• Rated operational current Ie/DC-13 A 2 at 24 V,
according to utilization categories (IEC 60947-5-1) 0.27 at 230 V
• Rated operational current Ie/AC-15 A 5 at 24 V and 230 V
according to utilization categories (IEC 60947-5-1)
Short-circuit protection
Short-circuit test with fuse links of
operational class gG
with short-circuit current Ik = 1 kA according to
IEC 60947-5-1
• DIAZED, type 5SB A 10
Min. contact load 12 V DC/10 mA
(reliability: 1 ppm)
Mechanical endurance Operat- 20 x 106
ing
cycles
Electrical endurance Operat- 3 x 105
(resistive load at 250 V AC) ing
cycles
1) AC voltages, 50 Hz; for 60 Hz operation, the lower response value must be
increased by 10%; the power loss will decrease slightly.
2)
Capacitive loads can result in micro-welding on the contacts.

Siemens IC 10 · 2023 5/45


© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
LZS coupling relays with plug-in relays

■ Selection and ordering data


Version Rated control supply Contacts, Width Article No. Price PU PS* PG
voltage Us number of per PU (UNIT,
at 50/60 Hz AC CO SET, M)
contacts
V mm
Complete units, 11- and 14-pole, PT series
Complete units with plug-in socket Screw terminals
For snap-on mounting on TH 35 DIN rail
Comprising:
• Coupling relays with plug-in relays
• Standard plug-in socket with screw terminals
• LED module (24 V DC version: LED module with freewheeling
diode)
• Fixing/ejection brackets
• Labels
3 CO contacts 24 DC 3 28 LZS:PT3A5L24 1 5 units 41H
LZS:PT3A5L24 24 AC LZS:PT3A5R24 1 5 units 41H
115 AC LZS:PT3A5S15 1 5 units 41H
5

230 AC LZS:PT3A5T30 1 5 units 41H


4 CO contacts 24 DC 4 28 LZS:PT5A5L24 1 5 units 41H
24 AC LZS:PT5A5R24 1 5 units 41H
115 AC LZS:PT5A5S15 1 5 units 41H
230 AC LZS:PT5A5T30 1 5 units 41H
Complete units with plug-in socket
With logical separation
For snap-on mounting on TH 35 DIN rail
Comprising:
• Coupling relays with plug-in relays
• Plug-in socket with logical separation and screw terminals
• LED module (24 V DC version: LED module with freewheeling
diode)
• Fixing/ejection brackets
• Labels
4 CO contacts 24 DC 4 28 LZS:PT5B5L24 1 5 units 41H
24 AC LZS:PT5B5R24 1 5 units 41H
115 AC LZS:PT5B5S15 1 5 units 41H
230 AC LZS:PT5B5T30 1 5 units 41H
Complete units, 8- and 14-pole, PT series
Complete units with plug-in socket Plug-in terminals
With logical separation (push-in)
For snap-on mounting on TH 35 DIN rail
Comprising:
• Coupling relays with plug-in relays
• Plug-in socket with logical separation and plug-in terminals (push-in)
• LED module (24 V DC version: LED module with freewheeling
diode)
• Fixing/ejection brackets
• Labels
2 CO contacts 24 DC 2 28 LZS:PT2D5L24 1 5 units 41H
230 AC LZS:PT2D5T30 1 5 units 41H
4 CO contacts 24 DC 4 28 LZS:PT5D5L24 1 5 units 41H
LZS:PT5D5L24 24 AC LZS:PT5D5R24 1 5 units 41H
115 AC LZS:PT5D5S15 1 5 units 41H
230 AC LZS:PT5D5T30 1 5 units 41H

Note:
Logical separation: The terminals for the contacts and the
terminals for the coil are arranged on separate levels, e.g. above
for contacts and below for the coil. Logical separation is not
necessarily protective separation.
Protective separation: Protective separation prevents voltage
of one circuit affecting another circuit with sufficient protection
(IEC 61140).

* You can order this quantity or a multiple thereof.


5/46 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
LZS coupling relays with plug-in relays

Version Rated control supply Contacts, Width Article No. Price PU PS* PG
voltage Us number of per PU (UNIT,
at 50/60 Hz AC CO SET, M)
contacts
V mm
Individual modules for customer assembly, PT series
Industrial relays, 8-, 11-, and 14-pole
Mini industrial relays
• With test bracket and mechanical
switch position indicator, without LED1)
24 DC 2 22.5 LZX:PT270024 1 1 unit 41H
3 LZX:PT370024 1 1 unit 41H
4 LZX:PT570024 1 1 unit 41H
LZX:PT370024 24 AC 2 22.5 LZX:PT270524 1 1 unit 41H
3 LZX:PT370524 1 1 unit 41H
4 LZX:PT570524 1 1 unit 41H
115 AC 2 22.5 LZX:PT270615 1 1 unit 41H
3 LZX:PT370615 1 1 unit 41H

5
4 LZX:PT570615 1 1 unit 41H
230 AC 2 22.5 LZX:PT270730 1 1 unit 41H
3 LZX:PT370730 1 1 unit 41H
4 LZX:PT570730 1 1 unit 41H
• With hard gold-plating
24 DC 4 22.5 LZX:PT580024 1 1 unit 41H
230 AC LZX:PT580730 1 1 unit 41H
• Without test bracket
24 DC 4 22.5 LZX:PT520024 1 1 unit 41H
230 AC LZX:PT520730 1 1 unit 41H
Plug-in sockets for PT relays
Standard plug-in sockets Screw terminals
For mounting on TH 35 DIN rail
-- 2 28 LZS:PT78720 1 1 unit 41H
3 LZS:PT78730 1 1 unit 41H
4 LZS:PT78740 1 1 unit 41H

LZS:PT78740
Plug-in sockets with logical separation
For mounting on TH 35 DIN rail
-- 2 28 LZS:PT78722 1 1 unit 41H
4 LZS:PT78742 1 1 unit 41H

LZS:PT78722
Plug-in sockets with logical separation Plug-in terminals
For mounting on TH 35 DIN rail (push-in)
-- 2 28 LZS:PT7872P 1 1 unit 41H
4 LZS:PT7874P 1 1 unit 41H

LZS:PT7874P
1)
The test bracket is designed to be non-latching. If the test bracket is
pressed further until 90° has been reached, two small lugs break off and
the test bracket can be latched in position.
Note:
Logical separation: The terminals for the contacts and the
terminals for the coil are arranged on separate levels, e.g. above
for contacts and below for the coil. Logical separation is not
necessarily protective separation.
Protective separation: Protective separation prevents voltage
of one circuit affecting another circuit with sufficient protection
(IEC 61140).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 5/47
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
LZS coupling relays with plug-in relays

Version Rated control supply Contacts, Width Article No. Price PU PS* PG
voltage Us number of per PU (UNIT,
at 50/60 Hz AC CO SET, M)
contacts
V mm
Individual modules for customer assembly, PT series
More individual modules
LED modules
• Red
- With freewheeling 24 DC -- 12.5 LZS:PTML0024 1 1 unit 41H
diode
LZS:PTML0024 - Without 24 AC/DC LZS:PTML0524 1 1 unit 41H
freewheeling diode 110 … 230 AC LZS:PTML0730 1 1 unit 41H
• Green
- With freewheeling 24 DC -- 12.5 LZS:PTMG0024 1 1 unit 41H
diode
- Without 24 AC/DC LZS:PTMG0524 1 1 unit 41H
freewheeling diode 110 … 230 AC LZS:PTMG0730 1 1 unit 41H
LZS:PT17021
5

Fixing/ejection brackets for PT base


With logical separation
Screw terminals -- -- 26 LZS:PT17021 100 10 units 41H
and plug-in terminals
(push-in)
Fixing/ejection brackets for standard plug-in socket
Without logical separation
LZS:PT17024 Screw terminals -- -- 26 LZS:PT17024 100 10 units 41H
Labels
-- -- 26 LZS:PT17040 100 10 units 41H
RC elements
LZS:PT17040 6 ... 60 AC -- 26 LZS:PTMU0524 1 1 unit 41H
110 … 230 AC LZS:PTMU0730 1 1 unit 41H
Freewheeling diodes with connection to A1
6 … 230 DC -- 26 LZS:PTMT00A0 1 1 unit 41H
Connecting combs for PT screw base
6-pole, 10 A current-carrying capacity,
LZS:PTMU0730 natural-colored
-- -- -- LZS:PT170R6 1 10 units 41H
Connecting brackets for PT push-in base
2-pole, 10 A current-carrying capacity,
natural-colored
-- -- -- LZS:PT170P1 1 10 units 41H
Individual modules for customer assembly, MT series
Industrial relays, 11-pole
Industrial relays with test bracket
Without LED 24 DC 3 35.5 LZX:MT321024 1 1 unit 41H
With LED LZX:MT323024 1 1 unit 41H
Without LED 24 AC 3 35.5 LZX:MT326024 1 1 unit 41H
With LED LZX:MT328024 1 1 unit 41H
Without LED 115 AC 3 35.5 LZX:MT326115 1 1 unit 41H
LZX:MT326024 With LED LZX:MT328115 1 1 unit 41H
Without LED 230 AC 3 35.5 LZX:MT326230 1 1 unit 41H
With LED LZX:MT328230 1 1 unit 41H
Plug-in sockets Screw terminals
For mounting on TH 35 DIN rail
-- -- 38 LZS:MT78750 1 1 unit 41H
Fixing brackets
-- -- 38 LZS:MT28800 1 1 unit 41H

LZS:MT78750
Note:
Logical separation: The terminals for the contacts and the
terminals for the coil are arranged on separate levels, e.g. above
for contacts and below for the coil. Logical separation is not
necessarily protective separation.
Protective separation: Protective separation prevents voltage of
one circuit affecting another circuit with sufficient protection
(IEC 61140).
SITOP DC power supplies such as 6EP1331-5BA00 or
6EP1331-5BA10 can be used for unavailable coil voltages,
see page 15/1 or Catalog KT 10.1.

* You can order this quantity or a multiple thereof.


5/48 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
LZS coupling relays with plug-in relays

Version Rated control supply Contacts, Width Article No. Price PU PS* PG
voltage Us number of per PU (UNIT,
at 50/60 Hz AC CO SET, M)
contacts
V mm
Complete units, 8-pole, 5 mm pinning, RT series
Complete units with standard plug-in socket Screw terminals
For snap-on mounting on TH 35 DIN rail
Comprising:
• Coupling relays with plug-in relays
• Standard plug-in socket with screw terminals
• LED module (24 V DC version: LED module with freewheeling diode)
• Fixing/ejection brackets
• Labels
1 CO contact 24 DC 1 15.5 LZS:RT3A4L24 1 5 units 41H
24 AC LZS:RT3A4R24 1 5 units 41H
LZS:RT4A4T30 115 AC LZS:RT3A4S15 1 5 units 41H
230 AC LZS:RT3A4T30 1 5 units 41H
2 CO contacts 24 DC 2 15.5 LZS:RT4A4L24 1 5 units 41H
24 AC LZS:RT4A4R24 1 5 units 41H

5
115 AC LZS:RT4A4S15 1 5 units 41H
230 AC LZS:RT4A4T30 1 5 units 41H
Complete units with plug-in socket
With logical separation
For snap-on mounting on TH 35 DIN rail
Comprising:
• Coupling relays with plug-in relays
• Plug-in socket with logical separation and screw terminals
• LED module (24 V DC version: LED module with freewheeling diode)
• Fixing/ejection brackets
• Labels
1 CO contact 24 DC 1 15.5 LZS:RT3B4L24 1 5 units 41H
24 AC LZS:RT3B4R24 1 5 units 41H
LZS:RT4B4T30 115 AC LZS:RT3B4S15 1 5 units 41H
230 AC LZS:RT3B4T30 1 5 units 41H
2 CO contacts 24 DC 2 15.5 LZS:RT4B4L24 1 5 units 41H
24 AC LZS:RT4B4R24 1 5 units 41H
115 AC LZS:RT4B4S15 1 5 units 41H
230 AC LZS:RT4B4T30 1 5 units 41H
Complete units with plug-in socket Plug-in terminals
With logical separation (push-in)
For snap-on mounting on TH 35 DIN rail
Comprising:
• Coupling relays with plug-in relays
• Plug-in socket with logical separation and plug-in terminals (push-in)
• LED module (24 V DC version: LED module with freewheeling diode)
• Fixing/ejection brackets
• Labels
1 CO contact 24 DC 1 15.5 LZS:RT3D4L24 1 5 units 41H
24 AC LZS:RT3D4R24 1 5 units 41H
LZS:RT3D4L24 115 AC LZS:RT3D4S15 1 5 units 41H
230 AC LZS:RT3D4T30 1 5 units 41H
2 CO contacts 24 DC 2 15.5 LZS:RT4D4L24 1 5 units 41H
24 AC LZS:RT4D4R24 1 5 units 41H
115 AC LZS:RT4D4S15 1 5 units 41H
230 AC LZS:RT4D4T30 1 5 units 41H

Note:
Logical separation: The terminals for the contacts and the
terminals for the coil are arranged on separate levels, e.g. above
for contacts and below for the coil. Logical separation is not
necessarily protective separation.
Protective separation: Protective separation prevents voltage
of one circuit affecting another circuit with sufficient protection
(IEC 61140).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 5/49
© Siemens 2023

Switching devices – Contactors and contactor assemblies – Contactor relays and relays
Coupling relays
LZS coupling relays with plug-in relays

Version Rated control Contacts, Width Article No. Price PU PS* PG


supply voltage Us number per PU (UNIT,
at 50/60 Hz AC of CO SET, M)
contacts
V mm
Individual modules for customer assembly, RT series
Print relays, 8-pole, 5 mm pinning
Print relays
With hard gold-plating
Version with 1 CO contact
LZX:RT314024 24 DC 1 12.7 LZX:RT315024 1 1 unit 41H
230 AC LZX:RT315730 1 1 unit 41H
Print relays
Version with 1 CO contact
24 DC 1 12.7 LZX:RT314024 1 1 unit 41H
24 AC LZX:RT314524 1 1 unit 41H
115 AC LZX:RT314615 1 1 unit 41H
230 AC LZX:RT314730 1 1 unit 41H
5

Version with 2 CO contacts


12 DC 2 12.7 LZX:RT424012 1 1 unit 41H
LZS:RT78725 24 DC LZX:RT424024 1 1 unit 41H
24 AC LZX:RT424524 1 1 unit 41H
115 AC LZX:RT424615 1 1 unit 41H
230 AC LZX:RT424730 1 1 unit 41H
Standard plug-in sockets Screw terminals
For mounting on TH 35 DIN rail
-- -- 15.5 LZS:RT78725 1 1 unit 41H
Plug-in sockets with logical separation
For mounting on TH 35 DIN rail
LZS:RT78726 -- -- 15.5 LZS:RT78726 1 1 unit 41H
Plug-in sockets with logical separation Plug-in terminals
For mounting on TH 35 DIN rail (push-in)
-- -- 15.5 LZS:RT7872P 1 1 unit 41H
LED modules
• Red
With freewheeling diode 24 DC -- 15.5 LZS:PTML0024 1 1 unit 41H
Without freewheeling 24 AC/DC -- LZS:PTML0524 1 1 unit 41H
diode 110 ... 230 AC -- LZS:PTML0730 1 1 unit 41H
LZS:RT7872P • Green
With freewheeling diode 24 DC -- 15.5 LZS:PTMG0024 1 1 unit 41H
Without freewheeling 24 AC/DC -- LZS:PTMG0524 1 1 unit 41H
diode 110 ... 230 AC -- LZS:PTMG0730 1 1 unit 41H

LZS:PTML0024
Fixing/ejection brackets
For RT base
-- -- 15.5 LZS:RT17016 100 10 units 41H
Labels
-- -- 15.5 LZS:RT17040 100 10 units 41H
LZS:RT17016
RC elements
6 ... 60 AC -- 15.5 LZS:PTMU0524 1 1 unit 41H
110 ... 230 AC LZS:PTMU0730 1 1 unit 41H
Freewheeling diodes with connection to A1
LZS:RT17040
6 … 230 DC -- 15.5 LZS:PTMT00A0 1 1 unit 41H
Connecting combs for RT screw base
8-pole, -- -- -- LZS:RT170R8 1 10 units 41H
10 A current-carrying
capacity, natural-colored
LZS:PTMU0730 Connecting brackets for push-in base
2-pole, -- -- -- LZS:RT170P1 100 10 units 41H
10 A current-carrying
capacity, natural-colored
Note:
SITOP DC power supplies such as 6EP1331-5BA00 or
6EP1331-5BA10 can be used for unavailable coil voltages,
see page 15/1 or Catalog KT 10.1.

* You can order this quantity or a multiple thereof.


5/50 Siemens IC 10 · 2023 Illustrations are approximate
6
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices

Price groups Solid-state switching devices


PG 14O, 41B, 41C, 41E, 41H, 41L, 42G, for resistive/inductive loads
42J, 42S SIRIUS 3RF2 solid-state relays and
contactors
6/2 Introduction
6/117 General data
SIRIUS 3RW soft starters Solid-state relays
6/5 General data 6/121 - General data
High Performance soft starters 6/122 - SIRIUS 3RF21 solid-state relays,
3RW55 soft starters 1-phase, 22.5 mm
6/15 - General data 6/128 - SIRIUS 3RF20 solid-state relays,
6/29 - Standard (inline) circuit 1-phase, 45 mm
6/33 - Inside-delta circuit 6/132 - SIRIUS 3RF22 solid-state relays,
6/37 - Accessories 3-phase, 45 mm
3RW55 Failsafe soft starters Solid-state contactors
6/39 - General data 6/135 - General data
6/51 - Standard (inline) circuit 6/136 - SIRIUS 3RF23 solid-state contactors,
6/52 - Inside-delta circuit 1-phase
6/53 - Accessories 6/146 - SIRIUS 3RF24 solid-state contactors,
General Performance soft starters 3-phase

6
3RW52 soft starters SIRIUS 3RF29 function modules
6/55 - General data 6/150 General data
6/67 - Standard (inline) circuit 6/152 SIRIUS converters for 3RF2
6/69 - Inside-delta circuit
6/71 - Accessories 6/153 SIRIUS load monitoring for 3RF2
Basic Performance soft starters 6/154 SIRIUS heating current monitoring
for 3RF2
3RW50 soft starters
6/73 - General data 6/155 SIRIUS power controllers for 3RF2
6/81 - Standard (inline) circuit 6/157 SIRIUS power regulators for 3RF2
6/82 - Accessories
SIRIUS 3RF34 solid-state switching
3RW40 soft starters
devices for switching motors
6/84 - General data
6/92 - Standard (inline) circuit Solid-state contactors
6/94 - Accessories 6/159 General data
3RW30 soft starters 6/162 SIRIUS 3RF34 solid-state contactors,
6/96 - General data 3-phase
6/103 - Standard (inline) circuit 6/165 SIRIUS 3RF34 solid-state reversing
6/104 - Accessories contactors, 3-phase
Spare parts
6/106 For 3RW55
6/110 For 3RW55 Failsafe
6/112 For 3RW52
6/115 For 3RW50
Software
14/4 Simulation Tool for Soft Starters (STS)
14/5 SIRIUS Soft Starter ES (TIA Portal)
14/8 SIRIUS 3RW soft starter block library for
SIMATIC PCS 7
14/25 SIRIUS Sim

Siemens IC 10 · 2023
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices

Introduction

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter Industry Online Support (SIOS) topic page, see
Industry Mall, see www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/109747404
TIA Selection Tool Cloud (TST Cloud), see Simulation Tool for Soft Starters (STS), see page 6/9 or
www.siemens.com/tstcloud/?node=Sirius3rwFolder https://support.industry.siemens.com/cs/ww/en/view/101494917
Conversion tool, see www.siemens.com/conversion-tool

3RW55 3RW55 Failsafe 3RW52 3RW50 3RW40 3RW30


Article No. Page
3RW soft starters
6

High Performance soft starters


3RW55 soft starters • TIA integration optional 3RW55..-.HA.. 6/15
• Plug-in communications modules for PROFINET, PROFIBUS, EtherNet/IP and Modbus
• Removable HMI module with color display, local interface and slot for
a micro SD memory card
• Extended protection functions
• Up to 1 200 kW at 400 V (can be used in supply systems up to 690 V)
• Automatic parameterization for simple commissioning and reliability even under changing
load conditions
• Hybrid switching technology for minimum power loss and 3-phase motor control for
optimum/symmetrical motor control
• Pump stop for reduced mechanical loading and optimum pump stop control
• ATEX/IECEx certification
• System redundancy S2 (with PROFINET High-Feature communications module)
3RW55 Failsafe • TIA integration optional 3RW55..-.HF.. 6/39
soft starters • Plug-in communications modules for PROFINET, PROFIBUS, EtherNet/IP and Modbus
• Removable HMI module with color display, local interface and slot for
a micro SD memory card
• Extended protection functions
• Up to 560 kW at 400 V (can be used in supply systems up to 480 V)
• SIL 1/PL c/STO without additional components
• SIL 3/PL e/STO with additional contactor and safety relay
• Hybrid switching technology for minimum power loss and 3-phase motor control for
optimum/symmetrical motor control
• Pump stop for reduced mechanical loading and optimum pump stop control
• ATEX/IECEx certification
• System redundancy S2 (with PROFINET High-Feature communications module)
General Performance soft starters
3RW52 soft starters • TIA integration optional 3RW52 6/55
• Plug-in communications modules for PROFINET, PROFIBUS, EtherNet/IP and Modbus
• HMI modules optional
• Soft starting and stopping
• Current limiting
• Motor overload protection (optionally with thermistor motor protection)
• Analog output (optional)
• Up to 560 kW at 400 V (can be used in supply systems up to 600 V)
• Hybrid switching technology for minimum power loss and 3-phase motor control for
optimum/symmetrical motor control
• Soft Torque for reduced mechanical loading and optimum pump stop
• Parameterization using potentiometers

6/2 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices

Introduction

3RW55 3RW55 Failsafe 3RW52 3RW50 3RW40 3RW30


Article No. Page
3RW soft starters
Basic Performance soft starters
3RW50 soft starters • TIA integration optional 3RW50 6/73
• Communications modules for PROFINET, PROFIBUS, EtherNet/IP and Modbus
• HMI modules optional
• Soft starting and stopping
• Current limiting
• Motor overload protection (optionally with thermistor motor protection)
• Analog output (optional)

6
• Up to 315 kW at 400 V (can be used in supply systems up to 600 V)
• Hybrid switching technology for minimum power loss and 2-phase motor control
• Soft Torque for reduced mechanical loading and optimum pump stop
• Parameterization using potentiometers
• ATEX/IECEx certification
3RW40 soft starters • Soft starting and stopping 3RW40 6/84
• Current limiting
• Motor overload protection (optionally with thermistor motor protection)
• Up to 55 kW at 400 V (can be used in supply systems up to 600 V)
• Hybrid switching technology for minimum power loss and 2-phase motor control
• ATEX certification
3RW30 soft starters • Soft starting with voltage ramp 3RW30 6/96
• Up to 55 kW at 400 V (can be used in supply systems up to 480 V)

Use of SIRIUS 3RW soft starters in conjunction with IE3 and Decision-making support for motor starting – Starting and
IE4 motors running three-phase asynchronous motors efficiently
Note:
For the use of SIRIUS 3RW soft starters in conjunction with highly
efficient IE3 and IE4 motors, please observe the information on
dimensioning and configuring, see Application Manual.
More information, see page 1/8.

Decision-making support tool for motor starting


By asking some short questions about the application, this tool
provides the optimum individual drive solution.
Based on this approach, you are taken to the correct product
configurator where you can select suitable products, see
www.siemens.com/motorstart-guide.

Siemens IC 10 · 2023 6/3


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices

Introduction

More information
Industry Mall, see www.siemens.com/product?3RF Online configurator, see www.siemens.com/sirius/configurators
Conversion tool, see www.siemens.com/conversion-tool

3RF21 3RF20 3RF22 3RF23 3RF24 3RF29 3RF34 (motor)


Article No. Page
SIRIUS solid-state switching devices for switching resistive/inductive loads
Solid-state relays
Solid-state relays • Widths of 22.5 mm and 45 mm 3RF21 6/122
• Compact and space-saving design 3RF20 6/128
3RF22 6/132
• "Zero-point switching" version
6

• Mounting on existing cooling surfaces


Solid-state contactors
Solid-state contactors • Complete units comprising a solid-state relay and an optimized heat sink, 3RF23 6/136
"ready to use" 3RF24 6/146
• Compact and space-saving design
• Versions for resistive loads "zero-point switching"
and inductive loads "instantaneous switching"
• Special "low noise" and "short-circuit-proof" versions
Function modules
For extending the functionality of the 3RF21 solid-state relays and the
3RF23 solid-state contactors for many different applications
Converters • For converting an analog input signal into an on/off ratio; 3RF2900-0EA18 6/152
can also be used on 3RF22 and 3RF24 3-phase switching devices
Load monitoring • For load monitoring of one or more loads (partial loads) 3RF29..-0FA08, 6/153
3RF29.0-0GA1.
Heating current monitoring • For load monitoring of one or more loads (partial loads); 3RF29..-0JA.. 6/154
remote teach
Power controllers • For setting the current by means of a solid-state switching device 3RF29..-0KA.. 6/155
depending on a setpoint value set by the power controller.
There is a choice of full-wave control and generalized phase control.
Power regulators • For regulating the current by means of a solid-state switching device, 3RF29.0-0HA.. 6/157
depending on a setpoint value set by the power regulator.
Closed-loop control: full-wave control or generalized phase control
SIRIUS solid-state switching devices for switching motors
Solid-state contactors
Solid-state contactors, solid-state • Complete units in the insulated enclosure with integrated heat sink, 3RF34 6/162, 6/165
reversing contactors "ready to use"
• Compact and space-saving design
• Version for motors, "instantaneous switching"

Use of SIRIUS solid-state switching devices for switching


motors in conjunction with IE3 and IE4 motors
Note:
For the use of SIRIUS 3RF solid-state switching devices for
switching motors in conjunction with highly efficient IE3 and
IE4 motors, please observe the information on dimensioning
and configuring, see Application Manual.
For more information, see page 1/8.

6/4 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General data

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter Simulation Tool for Soft Starters (STS), see page 6/9 or
Industry Mall, see www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/101494917
TIA Selection Tool Cloud (TST Cloud), see SIRIUS Soft Starter ES (TIA Portal), see page 6/9 or
www.siemens.com/tstcloud/?node=Sirius3rwFolder https://support.industry.siemens.com/cs/ww/en/ps/24230/dl
Industry Online Support (SIOS) topic page, see Decision-making support for motor starting – Starting and running three-phase
https://support.industry.siemens.com/cs/ww/en/view/109747404 asynchronous motors efficiently see www.siemens.com/motorstart-guide
Conversion tool, see www.siemens.com/conversion-tool

Video: Soft starter teaser

SIRIUS 3RW soft starters – as versatile as your application

High 3RW55 ( 3)
5.5 ... 710/1 200 kW ( 3)
Performance

6
3-phase controlled
3RW55 Failsafe
5.5 ... 315/560 kW ( 3) ( 3)

TIA Integration
General 3RW52
5.5 ... 315/560 kW ( 3)
Performance
( 3)

2-phase controlled
3RW50
Basic 75 ... 315 kW
Performance
3RW40
5.5 ... 55 kW

3RW30
1.5 ... 55 kW

IC01_00698a
Typical
Pumping Ventilating Compressing Conveying Processing
applications

SIRIUS 3RW soft starters

Siemens IC 10 · 2023 6/5


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General data

Applications High Performance General Basic Performance


Performance
SIRIUS soft starters 3RW55/3RW55-F 3RW52 3RW50 3RW40 3RW30
Selection aid for soft starters
Normal starting (CLASS 10)
Pumps ● ● ● ● ●
Pumps with special pump stop ● ❍ ❍
(to prevent water hammer)
Heat pumps ● ● ● ● ●
Hydraulic pumps ● ● ● ● ❍
Presses ● ● ● ● ❍
Conveyor belts ● ● ● ● ❍
Roller conveyors ● ● ● ● ❍
Screw conveyors ● ● ● ● ❍
6

Escalators ● ● ● ●
Piston compressors ● ● ● ●
Screw compressors ● ● ● ●
Small fans1) ● ● ● ●
Centrifugal blowers ● ● ● ●
Bow thrusters ● ● ● ●

Heavy starting (CLASS 20)


Stirrers ● ❍ ❍ ❍
Extruders ● ❍ ❍ ❍
Lathes ● ❍ ❍ ❍
Milling machines ● ❍ ❍ ❍

Heavy starting (CLASS 30)


Large fans2) ●
Circular saws/bandsaws ●
Centrifuges ●
Mills ●
Crushers ●
1)
● Recommended soft starter The mass inertia of the fan is <10 times the mass inertia of the motor.
❍ Possible soft starter
2)
The mass inertia of the fan is 10 times the mass inertia of the motor.

6/6 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General data

Applications High Performance General Basic Performance


Performance
SIRIUS soft starters 3RW55 3RW55-F 3RW52 3RW50 3RW40 3RW30
General technical specifications
Operational current at 40 °C A 13 ... 2 217 13 ... 987 13 ... 987 143 ... 570 12.5 ... 106 3 ... 106
Operational voltage V 200 ... 6901) 200 ... 480 200 ... 600 200 ... 600 200 ... 600 200 ... 480
Operating power for three-phase motors
• At 400 V, at 40 °C
- Standard (inline) circuit kW 5.5 ... 710 5.5 ... 315 5.5 ... 315 75 ... 315 5.5 ... 55 1.5 ... 55
- Inside-delta circuit kW 11 ... 1 200 11 ... 560 11 ... 560 -- -- --
• At 460/480 V at 50 °C
- Standard (inline) circuit hp 7.5 ... 1 000 7.5 ... 400 7.5 ... 400 100 ... 400 7.5 ... 75 1.5 ... 75
- Inside-delta circuit hp 10 ... 1 700 10 ... 750 10 ... 750 -- -- --
Ambient temperature2) °C -25 ... +60 -25 ... +60 -25 ... +60 -25 ... +60 -25 ... +60 -25 ... +60
Soft starting/stopping ✓ ✓ ✓ ✓ ✓ ✓3)

6
Voltage ramp ✓ ✓ ✓ ✓ ✓ ✓
Starting voltage % 20 ... 100 20 ... 100 30 ... 100 30 ... 100 40 ... 100 40 ... 100
Ramp-up and ramp-down time s 0 ... 360 0 ... 360 0 ... 20 0 ... 20 0 ... 20 0 ... 203)
Pump stop (torque control)4) ✓ ✓ -- -- -- --
• Starting torque % 10 ... 100 10 ... 100 -- -- -- --
• Torque limit % 20 ... 200 20 ... 200 -- -- -- --
Soft Torque (torque limit) -- -- ✓ ✓ -- --
Integral bypass contact system ✓ ✓ ✓ ✓ ✓ ✓
Intrinsic device protection ✓ ✓ ✓ ✓ ✓ --
Motor overload protection ✓5) ✓5) ✓ ✓5) ✓5) --
Thermistor motor protection evaluation ✓ ✓ ✓6) ✓6) ✓6) --
Analog output ✓ ✓ ✓6) ✓6) -- --
Remote RESET ✓ ✓ ✓ ✓ ✓ --
Adjustable current limiting ✓ ✓ ✓ ✓ ✓ --
Inside-delta circuit1) ✓ ✓ ✓ -- -- --
Breakaway pulse ✓ ✓ -- -- -- --
Automatic parameterization ✓ ✓ -- -- -- --
Pump cleaning ✓ ✓ -- -- -- --
Condition monitoring ✓ ✓ -- -- -- --
User account administration7) ✓ ✓ -- -- -- --
Creep speed in both directions of rotation ✓ -- -- -- -- --
Reversing operation ✓ ✓ -- -- -- --
Reversing DC braking4)8) ✓ -- -- -- -- --
DC braking4)8) ✓ -- -- -- -- --
Dynamic DC braking4)8) ✓ -- -- -- -- --
Motor heating ✓ -- -- -- -- --
Communication function9) ✓ ✓ ✓ ✓ -- --
HMI module installable in the control ✓ ✓ ✓9) ✓9) -- --
cabinet door
Operating measured value display ✓ ✓ ✓9) ✓9) -- --
Logbooks ✓ ✓ ✓9) ✓9) -- --
Statistical data and slave pointer function ✓ ✓ ✓9) ✓9) -- --
Trace function7) ✓ ✓ -- -- -- --
Programmable control inputs and outputs ✓ ✓ -- -- -- --
Number of parameter sets 3 3 1 1 1 1
Parameterizable via software7) ✓ ✓ -- -- -- --
Number of controlled phases 3 3 3 2 2 2
Heavy starting CLASS 304) ✓ ✓ -- -- -- --
5)
✓ Function available When using the motor overload protection according to ATEX/IECEx,
-- Function not available an upstream contactor may be required, see page 6/13.
6) Special device versions only.
1)
Inside-delta circuit only up to operational voltage 600 V. 7)
2) With software Soft Starter ES (TIA Portal).
Note derating above 40 °C. 8)
3) Not possible in inside-delta circuit.
Only soft starting available for 3RW30. 9)
4) Only in conjunction with special accessories.
Calculate soft starter and motor with overdimension where required.

Siemens IC 10 · 2023 6/7


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General data
Constraints
105

NSB0_01704
The 3RW soft starters should always be designed on the basis
of the required rated operational current of the motor. 100

Rated operational current e in %


The motor ratings listed in the selection and ordering data are
95
rough guide values and designed for basic starting conditions
(CLASS 10). For other starting conditions, we recommend the 90
Simulation Tool for Soft Starters (STS).
85
Motor rating data in kW and hp are based on IEC 60947-4-1.
80
At an installation altitude above 2 000 m, the max. permissible
operational voltage is reduced to 480 V. 75
70
0 1 000 2 000 3 000 4 000 5 000
Installation altitude in m

Installation altitude for SIRIUS 3RW soft starters

The selection and ordering data were determined for the following constraints (stand-alone installation without auxiliary fan)
6

Applications High Performance General Basic Performance


Performance
SIRIUS soft starters 3RW55/3RW55-F 3RW52 3RW50 3RW40 3RW30
Constraints
Maximum starting time s 20 10 3

Maximum starting current in % Ie 300


of motor current
Maximum number of starts per hour 1/h 5 20

6/8 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General data
Simulation Tool for Soft Starters (STS) (see page 14/4) SIRIUS Soft Starter ES (TIA Portal) (see page 14/5 onwards)

Easy and clearly arranged parameter setting of the SIRIUS 3RW44 and
3RW55 soft starters with SIRIUS Soft Starter ES (TIA Portal)
The SIRIUS Soft Starter ES (TIA Portal) software permits quick
Easy input of motor and load data and easy parameterization, monitoring and diagnostics of
The Simulation Tool for Soft Starters (STS) provides a convenient SIRIUS 3RW44 and 3RW5 soft starters for service purposes.
means of designing soft starters using a simple, quick and easy-

6
• Transparent setting of the device functions and their
to-use interface. Entering the motor and load data will simulate parameters – online and offline
the application and prompt suggestions for suitable soft starters.
• Effective diagnostics functions on the soft starter and display
• Simple, quick and user-friendly interface of the most important measured values
• Detailed and up-to-date Siemens motor database, • Trace function (oscilloscope function) for recording measured
including IE3 and IE4 motors. values and events (only in the Professional software version)
• Simulation of heavy starting up to CLASS 30 • Time savings through shorter startup times
• Update-capable (e.g. motors, load types, functions) • Fast, low-cost licensing using a simple licensing procedure
• Fast simulations with minimum input data (also available online)
• Immediate, graphical curve charts of start operations with
limit values
• Table view of suitable soft starters for the application
The Simulation Tool for Soft Starters (STS) is available as a free
download for Windows and as an app (for Android and iOS).

Siemens IC 10 · 2023 6/9


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General data
SIRIUS 3RW soft starter block library for SIMATIC PCS 7 SIRIUS 3RW55 and 3RW55 Failsafe system redundancy S2
(see page 14/7 onwards) with PROFINET High-Feature communications module
(see pages 6/37 and 6/53)

Faceplate of the motor block


The PCS 7 block library for SIRIUS 3RW soft starter can be used
for simple and convenient integration of SIRIUS 3RW44, 3RW52
and 3RW55 soft starters into the SIMATIC PCS 7 process control
system. PROFINET High-Feature communications module 3RW5950-0CH00

The PCS 7 block library for SIRIUS 3RW soft starter contains The PROFINET High-Feature communications module for
the diagnostics and driver blocks that correspond to the the SIRIUS 3RW55 and SIRIUS 3RW55 Failsafe soft starters
supports the S2 system redundancy mechanisms of
6

SIMATIC PCS 7 diagnostics and driver concept as well as the


elements (symbols and faceplates) required for operator control PROFINET IO from firmware version 3.0 and can therefore
and process monitoring. be operated directly on fault-tolerant systems, such as
SIMATIC S7-400H and S7-1500H. As such, 3RW55 and 3RW55
SIRIUS Sim (see page 14/25 onwards) Failsafe soft starters can provide decisive added value also for
the field level of plants in which plant availability and control
system redundancy are priorities.

SIRIUS Sim 3RW55


The SIRIUS simulation tool can be used to quickly and easily test
functions and configurations in an office environment. These
configurations can then be loaded directly into real devices.
SIRIUS Sim V2.0 integrates the SIRIUS 3RW55 and
SIRIUS 3RW55 Failsafe soft starters with the following features:
• Complete parameterization of the SIRIUS 3RW55
High Performance soft starters
• Complete navigation with the same menu structure
as on the HMI
• Optional storage of the parameterization on a micro SD
memory card for transfer to the real soft starter
• Simulation of starting and stopping, including operating
phases as well as different fault conditions
SIRIUS Sim is available as a free download.

6/10 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General data
Circuit concept Configuration
3-phase controlled SIRIUS 3RW soft starters can be operated The solid-state 3RW soft starters are designed for normal
in two different types of circuit: starting. In case of heavy starting or increased starting
• Standard (inline) circuit frequency, a larger unit must be selected. The 3RW50 and
The controls for isolating and protecting the motor are 3RW52 soft starters may be used in isolated supply networks
simply connected in series with the soft starter. The motor (IT systems) up to 600 V AC and the 3RW55 soft starters even
is connected to the soft starter with three cables. up to 690 V.
• Inside-delta circuit For long starting times it is recommended to have a PTC sensor
The wiring is similar to that of star-delta (wye-delta) starters. or temperature switch in the motor. This also applies for the
The phases of the soft starter are connected in series with the ramp-down modes torque control, pump stop and DC braking,
individual motor windings. The soft starter then only has to because during the ramp-down time in these modes, an
carry the phase current, amounting to about 58% of the rated additional current loading applies in contrast to free ramp-down.
motor current (conductor current). No capacitive elements are permitted in the motor feeder
Comparison of the types of circuit between the SIRIUS 3RW soft starter and the motor (e.g. no
reactive-power compensation equipment). In addition, neither
L1 NSB0_00424
static systems for reactive power compensation nor dynamic
L2
PFC (Power Factor Correction) must be operated in parallel
L3 during starting and stopping of the soft starter. This is important
N to prevent faults arising on the compensation equipment and/or
PE the soft starter.
All elements of the main circuit (such as fuses and switching
devices) should be dimensioned for direct-on-line starting,

6
following the local short-circuit conditions. Fuses and switching
devices must be ordered separately. The harmonic component
load of the starting current must be taken into consideration for
the selection of motor starter protectors/circuit breakers
(selection of release). Please observe the maximum switching
frequencies specified in the technical specifications.
Notes:
When three-phase motors are switched on, voltage drops occur
as a rule on starters of all types (direct-on-line starters, star-delta
Standard (inline) circuit: Rated current Ie corresponds to the rated motor (wye-delta) starters, soft starters). The infeed transformer must
current In, three cables to the motor always be dimensioned such that the voltage dip when starting
the motor remains within the permissible tolerance. If the infeed
transformer is dimensioned with only a small margin, it is best for
L1 NSB0_00425
L2
the control voltage to be supplied from a separate circuit
L3
(independently of the main voltage) in order to avoid the
N potential switching off of the soft starter.
PE
For dimensioning soft starters, we recommend our Simulation Tool
for Soft Starters (STS), see page 6/9 or our Technical Support,
www.siemens.com/support-request.
U2 L2 Recommended parameters for the initial commissioning of
U1 our SIRIUS 3RW soft starters are listed in every report of
T1 T2 our Simulation Tool for Soft Starters (STS). In addition,
V1 our High Performance soft starters provide support by means
L1 V2 of their commissioning wizards.

W2 W1 T3 L3

Inside-delta circuit: Rated current Ie corresponds to approx. 58% of


the rated motor current In, six cables to the motor (as for star-delta
(wye-delta) starters)
Which circuit?
Using the standard (inline) circuit involves the lowest wiring
outlay. If the soft starter to motor connections are long, this circuit
is preferable.
The wiring complexity is twice as high when using the inside-
delta circuit, but a smaller device can be used with the same
rating. Thanks to the choice of operating mode between the
standard (inline) circuit and inside-delta circuit, it is always
possible to select the most favorable solution.
The braking function is possible only in the standard (inline) circuit.
The inside-delta circuit cannot be used in 690 V line supplies.

Siemens IC 10 · 2023 6/11


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General data
Motor feeders with soft starters There are operating states of the thyristors (caused, for example,
by high starting frequencies or heavy starting) that do not permit
The type of coordination according to which the motor feeder with an overload to be disconnected by the SIRIUS 3RW soft starter.
soft starter is mounted depends on the application-specific These cases are very rare but can not be ruled out in all cases.
requirements. Normally, fuseless mounting (combination of motor
starter protector/circuit breaker and soft starter) is sufficient. In accordance with IEC 60947-4-2, the SIRIUS 3RW soft starters
are dimensioned and checked for operation with up to 8 times
If type of coordination "2" is to be fulfilled, then semiconductor the rated operational current Ie. For currents larger than this,
fuses must be fitted in the motor feeder. reliable disconnection of an overcurrent by the SIRIUS 3RW
Type of coordination "1" according to IEC 60947-4-1: soft starter is not ensured. Such large overcurrents have to be
ToC
1
After a short-circuit incident, the unit is defective and disconnected by a switching device at a higher level (e.g. by
therefore unsuitable for further use (protection of a motor starter protector/circuit breaker or a fuse in conjunction
persons and system guaranteed). with an optional line contactor).
Motor protection by the SIRIUS 3RW soft starter is ensured for
ToC Type of coordination "2" according to IEC 60947-4-1: currents up to 8 times the rated operational current Ie in any
2
After a short-circuit incident the unit is suitable for case. Line protection is covered by the line-side motor starter
further use (protection of persons and system protector/circuit breaker or fuse.
guaranteed). These motor feeder components must be dimensioned
accordingly and the cable cross-sections must be chosen
The type of coordination refers to soft starters in to match.
combination with the stipulated protective device
(motor starter protector/circuit breaker, fuse), Line protection
not to any additional components in the feeder. Line protection in motor feeders with soft starters is always
covered by a fuse or a circuit breaker both in case of an overload
6

The types of coordination are indicated in the and in case of a short circuit. The circuit breaker must have an
corresponding tables by the symbols shown on overload release. That is the case for motor starter protectors
orange backgrounds. (e.g. SIRIUS 3RV20).

Feeder tests and results Circuit breakers without an overload release (e.g. SIRIUS 3RV23
motor starter protectors) must not be used because they do not
To keep the scope of feeder tests with SIRIUS 3RW soft starters provide overload protection. The feeder tests for these were
within economically reasonable limits, tests were conducted with therefore not performed. If the motor feeder with SIRIUS 3RW
feeder components (motor starter protectors/circuit breakers, soft starters is configured without a fuse, motor starter protectors
fuses) that cover the greatest number of use cases (different soft must be used that ensure tripping on an overload in all cases.
starter versions depending on, for example, line voltage, type of
circuit, or necessary overdimensioning). For the combined tests Motor protection
that were conducted, the values for the short-circuit breaking If fuses are used to provide protection against overload
capacity Iq in kA were determined and documented. and short circuit of the cables, the motor is protected by
If the short-circuit breaking capacity is the same, of course, the SIRIUS 3RW soft starter. If the constraints (simple starting
smaller motor starter protectors/circuit breakers or fuses can conditions CLASS 10, listed maximum values for starting
also be used for the selected soft starter provided the current, starting time and number of starts per hour) of page 6/8
dimensioning of the short-circuit components is suitable for the are observed, the motor feeders can be configured according to
connected three-phase motor and the line protection for the IEC as described in the section about soft starters (an optional
cables used. For type of coordination "2" (with semiconductor line contactor is not required). If these preconditions are met,
protection), it is also necessary to compare the characteristics the SIRIUS 3RW soft starters are able to trip on overloads to
because the protection function would no longer be completely protect the motor in any case.
ensured if too small a fuse were selected. If the soft starter does In other starting conditions and on heavy starting, the following
not have a motor protection function, the motor protection must must be considered:
also be dimensioned appropriately.
Trip classes
Setting the motor current
Tested fuseless switchgear assemblies comprising SIRIUS 3RW
If circuit breakers with an overload release are used soft starters and motor starter protectors only comply with
(e.g. SIRIUS 3RV20 motor starter protector), we recommend CLASS 10.
activating the motor protection function of the SIRIUS 3RW soft To configure tested motor feeders, for example, for CLASS 20
starter to protect the motor and setting the soft starter to the or CLASS 30, fuses must be used together with SIRIUS 3RW
rated operational current Ie of the motor. We recommend setting soft starters.
the motor starter protector/circuit breaker in such a way that it
provides line protection but does not usually trip before the soft Line contactor
starter when a motor overload occurs. In applications with high starting frequencies or heavy starting
Line protection and motor protection as of CLASS 20, we recommend combining fuses with the use of
a line contactor on the line side so that a motor overload is
Line protection and motor protection are not ensured in all disconnected by the fault signaling contact of the soft starter in
operating cases, depending on: any case (that is, even in rare cases in which disconnection by
• How the motor feeder is constructed (e.g. with fuses or motor the SIRIUS 3RW soft starter is no longer possible due to the
starter protectors/circuit breakers) operating state of the thyristors).
• Whether the SIRIUS 3RW soft starters are operated within
the specification relevant for the tests (IEC 60947-4-2)
• Or whether the documented constraints (see page 6/8)
have been observed

6/12 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General data
ATEX/IECEx-certified motor overload protection Line contactor or additional undervoltage release on the motor
starter protector/circuit breaker
Ambient temperature during operation
In many ATEX/IECEx applications no additional measures
The SIRIUS 3RW soft starters are approved for operation in (e.g. the use of a line contactor) are necessary with regard to
a temperature range of -25 to +60 °C. the motor feeder configuration.
The derating of the rated operational current must be taken The operation of the selected soft starter may, depending on the
into account for ambient temperatures above 40 °C. amplitude of the line voltage and the type of motor connection
For more information, see Equipment Manual and the technical (standard (inline) circuit or inside-delta circuit), result in the loss
product data sheet of the selected soft starter. of the certified motor overload protection according to
ATEX/IECEx if one of the two remedial measures listed below
Trip class (electronic overload protection) is not implemented.
The motor and cables must be dimensioned for the selected Remedial measures
trip class.
• An additional line contactor in the main circuit
The rated data of the soft starters refers to normal starting • An additional undervoltage release for a motor feeder
(CLASS 10). For heavy starting (> CLASS 10), the soft starter configuration with a motor starter protector/circuit breaker
may need to be overdimensioned as only a rated motor current
that is lower than the soft starter rated current can be set. The line contactor or the undervoltage release are connected to
error outputs 95, 96 and 98 of the selected soft starter.
Short-circuit protection
Note:
The SIRIUS 3RW soft starter does not have short-circuit
protection. Short-circuit protection must be ensured. For ATEX/IECEx applications, the accompanying information on
parameterization and commissioning must be observed in the
Line protection

6
ATEX/IECEx chapters of the Equipment Manual for the selected
Avoid impermissibly high cable surface temperatures by soft starter.
correctly dimensioning the cross-sections.
The cable cross-section must be adequately dimensioned.

Article number scheme


Product versions Article number
Device type High Performance soft starters 3RW55 @ @ – @ @ @ @ @
General Performance soft starters 3RW52 @ @ – @ @ @ @ @
Basic Performance soft starters 3RW50 @ @ – @ @ @ @ @
3RW40 @ @ – @ @ @ @ @
3RW30 @ @ – @ @ @ @ @
Size/rated operational current Ie e.g. 15 = 25 A in size S1 @@
Connection type e.g. 1 = screw terminal @
Soft starter functionality e.g. AC = with bypass and analog output, @@
3-phase controlled
Rated control supply voltage Us e.g. 0 = 24 V AC/DC @
Rated operational voltage Ue e.g. 4 = 200 ... 480 V AC @
Example 3RW52 1 5 – 1 A C 0 4
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in
versions for better understanding of the logic behind the the selection and ordering data.
article numbers.

Siemens IC 10 · 2023 6/13


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General data

■ Benefits
Can be flexibly deployed in many applications
Strong portfolio: Intelligent operation:
wide range of matching products concentrated, application-specific functionality
• The right hardware for all requirements, • Can be used in a wide variety of applications:
soft starters for tasks ranging from simple to demanding starting in Basic, Pumping, ventilating, compressing, conveying and processing
General and High Performance versions
• Integrated, self-learning automatic parameterization depending on
• Extensive portfolio for individual expansion: motor starting conditions
Optional HMIs for installation in the device or mounting on the control
cabinet door • Application-specific functionality such as pump cleaning and pump stop

• Communication via PROFINET, PROFIBUS, EtherNet/IP and Modbus • Condition monitoring:


Current and power monitoring with warning and alarm limits,
• Design enclosure with removable terminals, space-saving thanks to starting time monitoring
compact design and rugged thanks to coated printed circuit boards

• Can be used worldwide thanks to numerous certificates and approvals:


IEC, UL, CSA, CCC, ATEX/IECEx, shipbuilding

Efficient switching: Ready for a digital future:


hybrid switching technology on board data available whenever and wherever needed
6

• Energy-efficient switching and mechanical protection of the drive train • Support from tools and data during engineering
thanks to soft starters with hybrid switching technology
• Simulation Tool for Soft Starters for support during product selection
• Low-wear switching extends the service life of the devices
• Very simple, standardized commissioning and configuration via
• Soft starting prevents current peaks, thereby increasing the network Soft Starter ES in TIA Portal
stability
• Integration in the automation system via communication links
• Protection against disturbances in the application:
Mechanical protection for the drive train • Data availability and analysis:
large volumes of data at any time and anywhere, even into MindSphere

6/14 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter SIRIUS Soft Starter ES (TIA Portal), see page 6/9 or
Industry Mall, see www.siemens.com/product?3RW55 https://support.industry.siemens.com/cs/ww/en/ps/24230/dl
TIA Selection Tool Cloud (TST Cloud), see SIRIUS 3RW soft starter block library for SIMATIC PCS 7, see page 6/10 or
www.siemens.com/tstcloud/?node=3rw55 https://support.industry.siemens.com/cs/ww/en/view/109770336
Industry Online Support (SIOS) topic page, see Decision-making support for motor starting – Starting and running three-phase
https://support.industry.siemens.com/cs/ww/en/view/109747404 asynchronous motors efficiently, see www.siemens.com/motorstart-guide
Simulation Tool for Soft Starters (STS), see page 6/9 or SIRIUS Sim, see page 6/10 or
https://support.industry.siemens.com/cs/ww/en/view/101494917 https://support.industry.siemens.com/cs/ww/en/view/109763750
Conversion tool, see www.siemens.com/conversion-tool

Equipped with the utmost functionality, the SIRIUS 3RW55


High Performance soft starters confidently handle even difficult
starting and stopping operations. Thanks to innovative torque
control, the device can be used for drives with an output of
between 5.5 kW and 1 200 kW (at 400 V).
The functions have been specially designed to offer maximum
user friendliness. The HMI (with color display, local interface and
a slot for micro SD memory card) and plug-in communications
modules (PROFINET, PROFIBUS, EtherNet/IP and Modbus)
ensure maximum flexibility.

6
With their modern hybrid switching technology,
the SIRIUS 3RW55 soft starters offer efficient switching
for long-term, energy-saving use.

SIRIUS 3RW55 soft starters device family

5 1 3RW55 soft starter

2 Communications modules
3 Hinged cover
4 Fan covers
5 Terminal covers (size 2 to size 4)
1 6 Push-in lugs for wall mounting

6 7 IP65 door mounting kit


8 HMI soft starter connecting cable
3

7
IC01_00582d

2 4

SIRIUS 3RW55 High Performance soft starter with accessories (see page 6/37)

Siemens IC 10 · 2023 6/15


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data

■ Benefits
6

Product characteristics/function Performance features/benefits

Automatic parameterization Extremely easy commissioning and reliability even under changing
load conditions

Hybrid switching technology and 3-phase motor control Minimum power loss and optimum/symmetrical motor control

TIA integration – communications modules optional Efficient configuration and maximum flexibility in automation engineering

Removable HMI with color display, local interface, slot for Maximum flexibility with regard to user interface and intuitive menu guidance
micro SD memory card

Pump stop and torque control Reduced mechanical loading and optimum pump stop control

Certified according to ATEX/IECEx directive Suitable for the starting of explosion-proof motors

System redundancy S2 Simple and straight-forward integration into fault-tolerant automation systems

Direct integration into MindSphere via the OPC UA server Worldwide data availability for optimal plant operation

6/16 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data

■ Technical specifications
More information
Technical specifications, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/25099/faq
https://support.industry.siemens.com/cs/ww/en/ps/25099/td Simulation Tool for Soft Starters (STS), see page 6/9 or
Equipment Manual, see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/109753752

Type 3RW551. 3RW552., 3RW553. 3RW554. 3RW555.


-.HA.4 -.HA.5 -.HA.4 -.HA.6 -.HA.4 -.HA.6 -.HA.4 -.HA.6
Installation/fixing/dimensions
Width x height x depth mm 170 x 275 x 152 185 x 306 x 203 210 x 393 x 203 478 x 764 x 241
H

Type of mounting Screw fixing


Mounting position Vertical (can be rotated +/- 90° and tilted +/- 22.5° forward or backward)
Distance to be maintained with side-by-side
mounting

6
• Above mm 100
• At the side mm 5
• Below mm 75
Installation altitude at height above sea level, m 5 000 2 000 5 000 2 000 5 000 2 000
maximum1)
Degree of protection IP on the front IP20 IP00 (IP20 with cover) IP00
according to IEC 60529
Touch protection on the front Finger-safe for vertical Finger-safe for vertical touching from the front --
according to IEC 60529 touching from the front with cover
Ambient conditions
Ambient temperature
• During operation2) °C -25 ... +60
• During storage and transport °C -40 ... +80 -25 ... +80 -40 ... +80
Environmental category according to IEC 60721
• During operation 3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist),
3S2 (sand must not get into the devices), 3M6
• During storage 1K6 (only occasional condensation), 1C2 (no salt mist),
1S2 (sand must not get into the devices), 1M4
• During transport 2K2, 2C1, 2S1, 2M2 (max. height of fall 0.3 m)
1)
Derating from 1 000 m, see characteristic curve on page 6/8.
2)
Note derating above 40 °C.

Siemens IC 10 · 2023 6/17


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data

Type 3RW55..-.HA0. 3RW55..-.HA1.


Control circuit/control
Control supply voltage
• At AC/DC V 24/24 --/--
• At AC V -- 110 ... 250
• Relative negative tolerance/relative positive tolerance with AC % -20/20 -15/10
• Relative negative tolerance/relative positive tolerance with DC % -20/20 --/--
Frequency of the control supply voltage Hz 50 ... 60
• Relative negative tolerance/relative positive tolerance % -10/10
Type of overvoltage protection Varistors
Type of short-circuit protection for control circuit1) Fuse 4 A gG (Icu =1 kA), fuse 6 A quick-response (Icu =1 kA),
MCB C1 (Icu = 600 A), MCB C6 (Icu = 300 A)
1)
Not included in scope of supply.

Type 3RW55..-.HA.4 3RW55..-.HA.5 3RW55..-.HA.6


Power electronics
Operational voltage V 200 ... 480 200 ... 600 200 ... 690
• Relative negative tolerance/relative positive tolerance % -15/10
Operational voltage for inside-delta circuit V 200 ... 480 200 ... 600
• Relative negative tolerance/relative positive tolerance % -15/10
6

Operating frequency Hz 50 ... 60


• Relative negative tolerance/relative positive tolerance % -10/10
Minimum load [% of IM]1) % 10
Maximum cable length between soft starter and motor m 800
1)
Relative to set Ie.

6/18 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data

Type 3RW5513 3RW5514 10


3RW5515 3RW5516 3RW5517
Rated operational current Ie A 13 18 25 32 38
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 32/28.4/26 38/33.5/30.5
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 32/28.4/26 38/33.5/30.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43 43 43
- Start-up time 10 s 1/h 18 18 18 18 18
• 350% IM
- Start-up time 5 s 1/h 28 28 28 28 28
- Start-up time 10 s 1/h 10 10 10 10 10
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 32/28.4/26 38/33.5/30.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 21 21 21
- Start-up time 20 s 1/h 8 8 8 8 8

6
• 350% IM
- Start-up time 10 s 1/h 13 13 13 13 13
- Start-up time 20 s 1/h 4 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 29.6/27.2/23.6 33.5/30.5/27.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 26/23.6/21.2 29/26/23
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 30 s 1/h 7 7 7 7 7
- Start-up time 60 s 1/h 3 3 3 3 3
• 350% IM
- Start-up time 30 s 1/h 4 4 4 4 4
- Start-up time 60 s 1/h 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 2.5/13 3.5/18 5/25 6.5/32 7.5/38
• Minimum/maximum in inside-delta circuits A 4.3/22.5 6.1/31.1 8.7/43.3 11.3/55.4 13/65.8

Siemens IC 10 · 2023 6/19


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data

Type 3RW5521 3RW5524 3RW5525 3RW5526 3RW5527


Rated operational current Ie A 25 47 63 77 93
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 25/22.3/19.6 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 25/22.3/19.6 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43 43 43
- Start-up time 10 s 1/h 18 18 18 18 18
• 350% IM
- Start-up time 5 s 1/h 28 28 28 28 28
- Start-up time 10 s 1/h 10 10 10 10 10
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 25/22.3/19.6 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 21 21 21
- Start-up time 20 s 1/h 8 8 8 8 8
6

• 350% IM
- Start-up time 10 s 1/h 13 13 13 13 13
- Start-up time 20 s 1/h 4 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 25/22.3/19.6 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 25/22.3/19.6 43.4/38/34.4 53/48/43 68/62/56 82.5/75.5/65
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 30 s 1/h 7 7 7 7 7
- Start-up time 60 s 1/h 3 3 3 3 3
• 350% IM
- Start-up time 30 s 1/h 4 4 4 4 4
- Start-up time 60 s 1/h 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 5/25 10/47 13/63 16/77 19/93
• Minimum/maximum in inside-delta circuits A 8.7/43.3 17.3/81.4 22.5/109 27.7/133 32.9/161

6/20 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data

Type 10
3RW5534 3RW5535 3RW5536
Rated operational current Ie A 113 143 171
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 113/101/89 143/128/118 171/153/141
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43
- Start-up time 10 s 1/h 18 18 18
• 350% IM
- Start-up time 5 s 1/h 28 28 28
- Start-up time 10 s 1/h 10 10 10
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 21
- Start-up time 20 s 1/h 8 8 8

6
• 350% IM
- Start-up time 10 s 1/h 13 13 13
- Start-up time 20 s 1/h 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 109/97/85 128/113/103 141/129/117
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10
- Start-up time 40 s 1/h 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 89/81/74 108/98/88 117/105/93
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 30 s 1/h 7 7 7
- Start-up time 60 s 1/h 3 3 3
• 350% IM
- Start-up time 30 s 1/h 4 4 4
- Start-up time 60 s 1/h 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 23/113 29/143 34/171
• Minimum/maximum in inside-delta circuits A 39.8/195 50.2/247 58.9/296

Siemens IC 10 · 2023 6/21


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data

Type 3RW5543 3RW5544 3RW5545 3RW5546 3RW5547 10


3RW5548
Rated operational current Ie A 210 250 315 370 470 570
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
40/50/60 °C, AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43 43 40 20
- Start-up time 10 s 1/h 18 18 18 18 17 6
• 350% IM
- Start-up time 5 s 1/h 28 28 28 28 26 9
- Start-up time 10 s 1/h 10 10 10 10 10 1
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 551/490/445
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 21 21 17 8
- Start-up time 20 s 1/h 8 8 8 8 6 1
6

• 350% IM
- Start-up time 10 s 1/h 13 13 13 13 10 2
- Start-up time 20 s 1/h 4 4 4 4 2 --
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 162/146/130 200/180/160 231/207/183 258/230/202 272/254/236 284/262/240
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 138/122/106 160/140/120 183/159/135 202/174/160 210/190/170 220/200/180
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 30 s 1/h 7 7 7 7 7 7
- Start-up time 60 s 1/h 3 3 3 3 3 3
• 350% IM
- Start-up time 30 s 1/h 4 4 4 4 4 4
- Start-up time 60 s 1/h 1.8 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 42/210 50/250 63/315 74/370 94/470 114/570
• Minimum/maximum in inside-delta circuits A 72.7/363 86.6/433 109.1/545 128.2/640 162.8/814 197.5/987

6/22 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data

Type 3RW5552 3RW5553 3RW5554 3RW5556 3RW5558


Rated operational current Ie A 630 720 840 1 100 1 280
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 630/561/510 720/641/580 840/748/670 1 100/979/890 1 280/1 139/1 030
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 630/561/510 720/641/580 840/748/670 1 100/979/890 1 280/1 139/1 030
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 42 43 32
- Start-up time 10 s 1/h 18 18 18 18 12
• 350% IM
- Start-up time 5 s 1/h 28 28 25 27 17
- Start-up time 10 s 1/h 10 10 10 9 4
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 630/561/510 720/641/580 840/748/670 1 100/979/890 1 225/1 130/1 030
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 19 18 15
- Start-up time 20 s 1/h 8 8 7 7 5

6
• 350% IM
- Start-up time 10 s 1/h 13 13 10 9 1
- Start-up time 20 s 1/h 4 4 2 2 1
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 500/450/400 520/470/420 570/520/470 920/840/760 980/900/810
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 380/340/300 400/360/320 420/380/340 740/670/600 790/720/650
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 30 s 1/h 7 7 7 7 7
- Start-up time 60 s 1/h 3 3 3 3 3
• 350% IM
- Start-up time 30 s 1/h 4 4 4 4 4
- Start-up time 60 s 1/h 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 114/630 144/720 168/840 220/1 100 258/1 280
• Minimum/maximum in inside-delta circuits A 197.5/987 249.4/1 247 291/1 454 381.1/1 905 446.9/2 217

Siemens IC 10 · 2023 6/23


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data
Motor feeders according to IEC with 3RV2 motor starter protectors/3VA circuit breakers (without semiconductor protection)
Type of coordination "1", CLASS 10,
short-circuit breaking capacity Iq in kA, see table
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

Q1 Q1

Q11 Q11
NSB0_01902

IC01_00544
M M
3~ 3~

Soft starters Motor starter protectors/circuit breakers Motor starter protectors/circuit breakers
for 400 V systems for 500 V systems for 400 V systems for 500 V systems
Q11 Q1 Iq Q1 Iq Q1 Iq Q1 Iq
Type Type kA Type kA Type kA Type kA
Type of Standard (inline) circuit Inside-delta circuit
6

ToC
coordination 1
"1"
3RW5513 3RV2032-4TA10 65 3RV2032-4TA10 18 3RV2032-4DA10 65 3RV2032-4DA10 18
3RW5514 3RV2032-4DA10 65 3RV2032-4DA10 15 3RV2032-4EA10 65 3RV2032-4EA10 15
3RW5515 3RV2032-4EA10 65 3RV2032-4EA10 15 3RV2032-4VA10 65 3RV2032-4VA10 15
3RW5516 3RV2032-4VA10 65 3RV2032-4VA10 10 3RV2032-4JA10 65 3RV2032-4JA10 10
3RW5517 3RV2032-4WA10 65 3RV2032-4WA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5521 -- -- -- -- -- -- -- --
3RW5524 3RV2032-4JA10 65 3RV2032-4JA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5525 3VA2163-7MN32-0AA0 65 3VA2163-7MN32-0AA0 20 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20
3RW5526 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20 3VA2216-7MN32-0AA0 65 3VA2216-7MN32-0AA0 20
3RW5527 3VA2216-7MN32-0AA0 15 3VA2216-7MN32-0AA0 10 3VA2220-7MN32-0AA0 15 3VA2220-7MN32-0AA0 10
3RW5534 3VA2216-7MN32-0AA0 65 -- -- 3VA2220-7MN32-0AA0 65 -- --
3RW5535 3VA2220-7MN32-0AA0 65 -- -- 3VA2325-7MN32-0AA0 65 -- --
3RW5536 3VA2325-7MN32-0AA0 30 3VA2325-7MN32-0AA0 10 3VA2440-7MN32-0AA0 30 3VA2440-7MN32-0AA0 10
3RW5543 3VA2325-7MN32-0AA0 65 3VA2325-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5544 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65
3RW5545 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5546 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5547 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
3RW5548 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
3RW5552 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65
3RW5553 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65
3RW5554 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65
3RW5556 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65 -- -- -- --
3RW5558 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65 -- -- -- --

Note:
The service factor and measurement inaccuracies, for example,
have been taken into account for the selection of the specified
motor starter protectors/circuit breakers; the specified short-
circuit breaking capacities Iq in kA are covered by combination
tests. Smaller motor starter protectors/circuit breakers from the
same series can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must match
the connected three-phase motor, the short-circuit and overload
requirements of the application, and the line protection for the
cables used.
When using braking functions, the use of fuses is recommended
to avoid the risk of false tripping of 3VA circuit breakers with
electronic motor protection function during braking.
In motor feeder tests with soft starters conducted in 690 V
systems, demonstrable short-circuit breaking capacities could
only be achieved using fuses (Iq > 5 to 10 kA).

6/24 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data
Motor feeders according to IEC with 3NA3 fuses
gG class full-range fuses for cable and line protection according
to IEC 60269-2, without semiconductor protection
Type of coordination "1",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1 F1 F1

Q21 Q21 Q21

Q11 Q11 Q11

IC01_00545a
NSB0_01904

IC01_00565
M M M
3~ 3~ 3~

Soft starters gG class fuse Line contactor (optional) gG class fuse Line contactor (optional)
for systems for systems for systems for systems for systems for systems for systems for systems

6
up to 690 V up to 480 V up to 690 V up to 600 V up to 480 V up to 600 V up to 480 V up to 600 V
in the supply in the supply in the delta in the delta
cable cable
Q11 F1 Q21 Q21 F1 Q21 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type
Type of ToC Standard (inline) circuit Inside-delta circuit
coordination 1
"1"
3RW5513 3NA3820-6 3RT2025 3RT2025 3NA3820-6 3RT2027 3RT2035 3RT2025 3RT2025
3RW5514 3NA3820-6 3RT2026 3RT2027 3NA3820-6 3RT2027 3RT2037 3RT2026 3RT2027
3RW5515 3NA3822-6 3RT2027 3RT2037 3NA3822-6 3RT2036 3RT2037 3RT2027 3RT2037
3RW5516 3NA3824-6 3RT2035 3RT2037 3NA3824-6 3RT2037 3RT2038 3RT2035 3RT2037
3RW5517 3NA3824-6 3RT2035 3RT2037 3NA3824-6 3RT2038 3RT2046 3RT2035 3RT2037
3RW5521 3NA3824-6 3RT2027 3RT2037 3NA3824-6 3RT2036 3RT2037 3RT2027 3RT2037
3RW5524 3NA3824-6 3RT2036 3RT2037 3NA3824-6 3RT2046 3RT2047 3RT2036 3RT2037
3RW5525 3NA3830-6 3RT2037 3RT2046 3NA3830-6 3RT2047 3RT1054 3RT2037 3RT2046
3RW5526 3NA3132-6 3RT2038 3RT2046 3NA3132-6 3RT1055 3RT1055 3RT2038 3RT2046
3RW5527 3NA3136-6 3RT2046 3RT2047 3NA3136-6 3RT1056 3RT1056 3RT2046 3RT2047
3RW5534 3NA3244-6 3RT1054 3RT1054 3NA3244-6 3RT1064 3RT1064 3RT1054 3RT1054
3RW5535 3NA3244-6 3RT1055 3RT1055 3NA3244-6 3RT1065 3RT1065 3RT1055 3RT1055
3RW5536 3NA3365-6 3RT1056 3RT1064 3NA3365-6 3RT1066 3RT1075 3RT1056 3RT1064
3RW5543 2 x 3NA3354-6 3RT1064 3RT1064 2 x 3NA3354-6 3RT1075 3RT1075 3RT1064 3RT1064
3RW5544 2 x 3NA3354-6 3RT1065 3RT1065 2 x 3NA3354-6 3RT1076 3RT1076 3RT1065 3RT1065
3RW5545 2 x 3NA3365-6 3RT1075 3RT1075 2 x 3NA3365-6 3TF68 3TF68 3RT1075 3RT1075
3RW5546 2 x 3NA3365-6 3RT1075 3RT1075 2 x 3NA3365-6 3TF69 3TF69 3RT1075 3RT1075
3RW5547 2 x 3NA3365-6 3RT1076 3RT1276 2 x 3NA3365-6 3TF69 3TF69 3RT1076 3RT1276
3RW5548 2 x 3NA3365-6 3TF68 3TF68 2 x 3NA3365-6 -- -- 3TF68 3TF68
3RW5552 2 x 3NA3365-6 3TF68 3TF69 -- -- -- 3TF68 3TF69
3RW5553 2 x 3NA3365-6 3TF69 3TF69 -- -- -- 3TF69 3TF69
3RW5554 2 x 3NA3365-6 -- -- -- -- -- -- --
3RW5556 3 x 3NA3365-6 -- -- -- -- -- -- --
3RW5558 3 x 3NA3365-6 -- -- -- -- -- -- --

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.
In inside-delta circuits, motor feeders with soft starters can only
be operated in systems with up to 600 V.

Siemens IC 10 · 2023 6/25


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data
Motor feeders according to IEC with 3NE1/3NB3 SITOR fuses
gR/gS class full-range fuses for semiconductor protection,
cable and line protection (gS)
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F’1

Q21

Q11
NSB0_01905

M
3~

Soft starters gR/gS class fuse Line contactor (optional)


for systems for systems for systems
6

up to 690 V up to 480 V up to 690 V


Q11 F’1 Q21 Q21
Type Type Type Type
Type of ToC Standard (inline) circuit
coordination 2
"2"
3RW5513 3NE1815-0 3RT2025 3RT2025
3RW5514 3NE1802-0 3RT2026 3RT2027
3RW5515 3NE1817-0 3RT2027 3RT2037
3RW5516 3NE1818-0 3RT2035 3RT2037
3RW5517 3NE1820-0 3RT2035 3RT2037
3RW5521 3NE1817-0 3RT2027 3RT2037
3RW5524 3NE1021-2 3RT2036 3RT2037
3RW5525 3NE1022-0 3RT2037 3RT2046
3RW5526 3NE1224-0 3RT2038 3RT2046
3RW5527 3NE1224-0 3RT2046 3RT2047
3RW5534 3NE1225-0 3RT1054 3RT1054
3RW5535 3NE1227-0 3RT1055 3RT1055
3RW5536 3NE1230-0 3RT1056 3RT1064
3RW5543 3NE1230-21) 3RT1064 3RT1064
3RW5544 3NE1331-0 3RT1065 3RT1065
3RW5545 3NE1334-2 3RT1075 3RT1075
3RW5546 3NE1334-2 3RT1075 3RT1075
3RW5547 3NE1436-2 3RT1076 3RT1276
3RW5548 3NE1437-2 3TF68 3TF68
3RW5552 3NB3350-1KK26 3TF68 3TF69
3RW5553 3NB3351-1KK26 3TF69 3TF69
3RW5554 3NB3351-1KK26 -- --
3RW5556 3NB3354-1KK26 -- --
3RW5558 3NB3357-1KK26 -- --
1)
For systems up to 500 V.
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.
In inside-delta circuits, a gR/gS class full-range fuse could not
provide the semiconductor protection of the delta-connected
soft starter with a short-circuit breaking capacity that is
adequate for practical use. In this case, we recommend using
aR class partial-range fuses for semiconductor protection for
type of coordination "2" (see page 6/27).

6/26 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data
Motor feeders according to IEC with 3NE8/3NE3/3NC3 fuses
aR class partial-range fuses for semiconductor protection
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1 F1 F1

Q21 Q21 Q21

F3 F3 F3

Q11 Q11 Q11


NSB0_01906

IC01_00546a

IC01_00566
M M M
3~ 3~ 3~

Soft starters gG class fuse aR class fuse Line contactor gG class fuse aR class fuse Line contactor (optional)
(optional)

6
for systems for systems for systems for systems for systems for systems for for for for
up to 690 V up to 690 V up to 480 V up to 690 V up to 600 V up to 600 V systems systems systems systems
up to up to up to up to
480 V 600 V 480 V 600 V
in the in the in the delta in the delta
supply supply
cable cable
Q11 F1 F3 Q21 Q21 F1 F3 Q21 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type Type Type
Type of ToC Standard (inline) circuit Inside-delta circuit
coordination 2
"2"
3RW5513 3NA3820-6 3NE8017-1 3RT2025 3RT2025 3NA3820-6 3NE8017-1 3RT2027 3RT2035 3RT2025 3RT2025
3RW5514 3NA3820-6 3NE8020-1 3RT2026 3RT2027 3NA3820-6 3NE8020-1 3RT2027 3RT2037 3RT2026 3RT2027
3RW5515 3NA3822-6 3NE8021-1 3RT2027 3RT2037 3NA3822-6 3NE8021-1 3RT2036 3RT2037 3RT2027 3RT2037
3RW5516 3NA3824-6 3NE8022-1 3RT2035 3RT2037 3NA3824-6 3NE8022-1 3RT2037 3RT2038 3RT2035 3RT2037
3RW5517 3NA3824-6 3NE8024-1 3RT2035 3RT2037 3NA3824-6 3NE8024-1 3RT2038 3RT2046 3RT2035 3RT2037
3RW5521 3NA3824-6 3NE8021-1 3RT2027 3RT2037 3NA3824-6 3NE8021-1 3RT2036 3RT2037 3RT2027 3RT2037
3RW5524 3NA3824-6 3NE8024-1 3RT2036 3RT2037 3NA3824-6 3NE8024-1 3RT2046 3RT2047 3RT2036 3RT2037
3RW5525 3NA3830-6 3NE3227 3RT2037 3RT2046 3NA3830-6 3NE3227 3RT2047 3RT1054 3RT2037 3RT2046
3RW5526 3NA3132-6 3NE3227 3RT2038 3RT2046 3NA3132-6 3NE3227 3RT1055 3RT1055 3RT2038 3RT2046
3RW5527 3NA3136-6 3NE3227 3RT2046 3RT2047 3NA3136-6 3NE3227 3RT1056 3RT1056 3RT2046 3RT2047
3RW5534 3NA3244-6 3NE3231 3RT1054 3RT1054 3NA3244-6 3NE3231 3RT1064 3RT1064 3RT1054 3RT1054
3RW5535 3NA3244-6 3NE3233 3RT1055 3RT1055 3NA3244-6 3NE3233 3RT1065 3RT1065 3RT1055 3RT1055
3RW5536 3NA3365-6 3NE3334-0B 3RT1056 3RT1064 3NA3365-6 3NE3334-0B 3RT1066 3RT1075 3RT1056 3RT1064
3RW5543 2 x 3NA3354-6 3NE3333 3RT1064 3RT1064 2 x 3NA3354-6 3NE3333 3RT1075 3RT1075 3RT1064 3RT1064
3RW5544 2 x 3NA3354-6 3NE3335 3RT1065 3RT1065 2 x 3NA3354-6 3NE3335 3RT1076 3RT1076 3RT1065 3RT1065
3RW5545 2 x 3NA3365-6 -- 3RT1075 3RT1075 2 x 3NA3365-6 -- 3TF68 3TF68 3RT1075 3RT1075
3RW5546 2 x 3NA3365-6 -- 3RT1075 3RT1075 2 x 3NA3365-6 -- 3TF69 3TF69 3RT1075 3RT1075
3RW5547 2 x 3NA3365-6 3NE3340-8 3RT1076 3RT1276 2 x 3NA3365-6 3NE3340-8 3TF69 3TF69 3RT1076 3RT1276
3RW5548 2 x 3NA3365-6 3NC3342-1U 3TF68 3TF68 2 x 3NA3365-6 3NC3342-1U -- -- 3TF68 3TF68
3RW5552 2 x 3NA3365-6 3NC3343-1U 3TF68 3TF69 -- 3NC3343-1U -- -- 3TF68 3TF69
3RW5553 2 x 3NA3365-6 3NC3343-1U 3TF69 3TF69 -- 3NC3343-1U -- -- 3TF69 3TF69
3RW5554 2 x 3NA3365-6 3NC3343-1U -- -- -- 3NC3343-1U -- -- -- --
3RW5556 3 x 3NA3365-6 3 x 3NE3340-8 -- -- -- 3 x 3NE3340-8 -- -- -- --
3RW5558 3 x 3NA3365-6 3 x 3NE3340-8 -- -- -- 3 x 3NE3340-8 -- -- -- --

Note: In inside-delta circuits, motor feeders with soft starters can only
be operated in systems with up to 600 V.
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.
For CLASS 10 applications, as an alternative to the 3NA3
gG class full-range fuses for cable and line protection (F1),
3RV2 motor starter protectors/3VA circuit breakers can also be
used, possibly with reduced short-circuit breaking capacity (see
page 6/24). In these cases, optional line contactors can be
dispensed with.

Siemens IC 10 · 2023 6/27


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > General data
Reversing operation with reversing contactors
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.
(Example circuit, see
3RW55 Equipment Manual, Appendix A.3)
Soft starters Reversing contactor assembly Reversing contactor
for systems up to 480 V for systems up to 690 V for systems up to 480 V for systems up to 690 V
Q11 Q21/Q22 Q21/Q22 Q21/Q22 Q21/Q22
Type Type Type Type Type
3RW5513 3RA2325 3RA2325 3RT2025 3RT2025
3RW5514 3RA2326 3RA2327 3RT2026 3RT2027
3RW5515 3RA2327 3RA2337 3RT2027 3RT2037
3RW5516 3RA2335 3RA2337 3RT2035 3RT2037
3RW5517 3RA2335 3RA2337 3RT2035 3RT2037
3RW5521 3RA2327 3RA2337 3RT2027 3RT2037
3RW5524 3RA2336 3RA2337 3RT2036 3RT2037
3RW5525 3RA2337 3RA2346 3RT2037 3RT2046
3RW5526 3RA2338 3RA2346 3RT2038 3RT2046
3RW5527 3RA2346 3RA2347 3RT2046 3RT2047
3RW5534 -- -- 3RT1054 3RT1054
3RW5535 -- -- 3RT1055 3RT1055
6

3RW5536 -- -- 3RT1056 3RT1064


3RW5543 -- -- 3RT1064 3RT1064
3RW5544 -- -- 3RT1065 3RT1065
3RW5545 -- -- 3RT1075 3RT1075
3RW5546 -- -- 3RT1075 3RT1075
3RW5547 -- -- 3RT1076 3RT1276
3RW5548 -- -- 3TF68 3TF68
3RW5552 -- -- 3TF68 3TF69
3RW5553 -- -- 3TF69 3TF69
3RW5554 -- -- -- --
3RW5556 -- -- -- --
3RW5558 -- -- -- --

DC braking with braking contactors


Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.
(Example circuit, see
3RW55 Equipment Manual, Appendix A.3)
Soft starters DC braking contactor DC braking contactor assembly
for systems up to 400 V for systems up to 480 V for systems up to 690 V
with 2 NC contacts + with 3 NO contacts with 3 NO contacts with 3 NO contacts with 3 NO contacts
2 NO contacts parallel parallel parallel parallel parallel
Q11 Q93 Q91 Q92 Q91 Q92
Type Type Type Type Type Type
3RW5513 3RT2517 3RT2015 3RT2016 3RT2015 3RT2016
3RW5514 3RT2518 3RT2015 3RT2017 3RT2015 3RT2023
3RW5515 3RT2526 3RT2015 3RT2025 3RT2015 3RT2025
3RW5516 3RT2526 3RT2015 3RT2025 3RT2015 3RT2027
3RW5517 3RT2535 3RT2015 3RT2027 3RT2015 3RT2027
3RW5521 3RT2526 3RT2015 3RT2025 3RT2015 3RT2025
3RW5524 3RT2535 3RT2016 3RT2027 3RT2016 3RT2035
3RW5525 -- 3RT2024 3RT2027 3RT2024 3RT2037
3RW5526 -- 3RT2025 3RT2035 3RT2025 3RT2037
3RW5527 -- 3RT2027 3RT2036 3RT2027 3RT2037
3RW5534 -- 3RT2035 3RT2037 3RT2035 3RT2038
3RW5535 -- 3RT2036 3RT2038 3RT2036 3RT2046
3RW5536 -- 3RT2037 3RT2046 3RT2037 3RT2047
3RW5543 -- 3RT2045 3RT2047 3RT2045 3RT1054
3RW5544 -- 3RT2045 3RT1055 3RT2045 3RT1055
3RW5545 -- 3RT2446 3RT1056 3RT2446 3RT1056
3RW5546 -- 3RT1055 3RT1056 3RT1055 3RT1064
3RW5547 -- 3RT1456 3RT1065 3RT1456 3RT1065
3RW5548 -- 3RT1456 3RT1066 3RT1456 3RT1075
3RW5552 -- 3RT1065 3RT1075 3RT1065 3RT1075
3RW5553 -- 3RT1065 3RT1075 3RT1065 3RT1075
3RW5554 -- 3RT1466 3RT1076 3RT1466 3RT1076
3RW5556 -- 3RT1476 3TF68 3RT1476 3TF68
3RW5558 -- 3RT1476 3TF69 3RT1476 3TF69

6/28 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
IE3 ready IE4 ready IE3/IE4 ready 3RW55 soft starters > Standard (inline) circuit

■ Selection and ordering data


For normal starting (CLASS 10E)

3RW551 3RW552.
At 40 °C At 50 °C Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at at current at at at at
230 V 400 V 500 V 690 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW kW A hp hp hp hp

6
Operational voltage 200 ... 480 V
13 3 5.5 -- -- 11.5 2 3 7.5 -- 3RW5513-@HA@4 1 1 unit 42S
18 4 7.5 -- -- 15.9 3 5 10 -- 3RW5514-@HA@4 1 1 unit 42S
25 5.5 11 -- -- 22.3 5 7.5 15 -- 3RW5515-@HA@4 1 1 unit 42S
32 7.5 15 -- -- 28.4 7.5 10 20 -- 3RW5516-@HA@4 1 1 unit 42S
38 11 18.5 -- -- 33.5 10 10 20 -- 3RW5517-@HA@4 1 1 unit 42S
47 11 22 -- -- 41.6 10 10 30 -- 3RW5524-@HA@4 1 1 unit 42S
63 18.5 30 -- -- 55.5 15 20 40 -- 3RW5525-@HA@4 1 1 unit 42S
77 22 37 -- -- 68 20 25 50 -- 3RW5526-@HA@4 1 1 unit 42S
93 22 45 -- -- 82.5 25 30 60 -- 3RW5527-@HA@4 1 1 unit 42S

Type of electrical connection for the control circuit


Screw terminals 1
Spring-loaded terminals 3

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/29
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > Standard (inline) circuit IE3 ready IE4 ready IE3/IE4 ready

For normal starting (CLASS 10E)

3RW553. 3RW554. 3RW555.


At 40 °C At 50 °C Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at at current at at at at
230 V 400 V 500 V 690 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW kW A hp hp hp hp
Operational voltage 200 ... 480 V
6

113 30 55 -- -- 101 30 30 75 -- 3RW5534-@HA@4 1 1 unit 42S


143 37 75 -- -- 128 40 40 100 -- 3RW5535-@HA@4 1 1 unit 42S
171 45 90 -- -- 153 50 50 100 -- 3RW5536-@HA@4 1 1 unit 42S
210 55 110 -- -- 186 60 60 150 -- 3RW5543-@HA@4 1 1 unit 42S
250 75 132 -- -- 220 60 75 150 -- 3RW5544-@HA@4 1 1 unit 42S
315 90 160 -- -- 279 75 100 200 -- 3RW5545-@HA@4 1 1 unit 42S
370 110 200 -- -- 328 100 125 250 -- 3RW5546-@HA@4 1 1 unit 42S
470 132 250 -- -- 416 150 150 350 -- 3RW5547-@HA@4 1 1 unit 42S
570 160 315 -- -- 504 150 200 400 -- 3RW5548-@HA@4 1 1 unit 42S
630 200 355 -- -- 561 200 200 450 -- 3RW5552-@HA@4 1 1 unit 42S
720 200 400 -- -- 641 200 250 500 -- 3RW5553-@HA@4 1 1 unit 42S
840 250 450 -- -- 748 250 300 600 -- 3RW5554-@HA@4 1 1 unit 42S
1 100 315 560 -- -- 979 350 400 850 -- 3RW5556-@HA@4 1 1 unit 42S
1 280 400 710 -- -- 1 139 400 450 1 000 -- 3RW5558-@HA@4 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


6/30 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
IE3 ready IE4 ready IE3/IE4 ready 3RW55 soft starters > Standard (inline) circuit
For normal starting (CLASS 10E)

3RW551. 3RW552.
At 40 °C At 50 °C Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at at current at at at at
230 V 400 V 500 V 690 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW kW A hp hp hp hp
Operational voltage 200 ... 600 V
13 3 5.5 7.5 -- 11.5 2 3 7.5 10 3RW5513-@HA@5 1 1 unit 42S
18 4 7.5 11 -- 15.9 3 5 10 10 3RW5514-@HA@5 1 1 unit 42S

6
25 5.5 11 15 -- 22.3 5 7.5 15 20 3RW5515-@HA@5 1 1 unit 42S
32 7.5 15 18.5 -- 28.4 7.5 10 20 25 3RW5516-@HA@5 1 1 unit 42S
38 11 18.5 22 -- 33.5 10 10 20 30 3RW5517-@HA@5 1 1 unit 42S
Operational voltage 200 ... 690 V
25 5.5 11 15 22 22.3 5 7.5 15 20 3RW5521-@HA@6 1 1 unit 42S
47 11 22 30 45 41.6 10 10 30 40 3RW5524-@HA@6 1 1 unit 42S
63 18.5 30 37 55 55.5 15 20 40 50 3RW5525-@HA@6 1 1 unit 42S
77 22 37 45 75 68 20 25 50 60 3RW5526-@HA@6 1 1 unit 42S
93 22 45 55 90 82.5 25 30 60 75 3RW5527-@HA@6 1 1 unit 42S

Type of electrical connection for the control circuit


Screw terminals 1
Spring-loaded terminals 3

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/31
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > Standard (inline) circuit IE3 ready IE4 ready IE3/IE4 ready

For normal starting (CLASS 10E)

3RW553. 3RW554. 3RW555.


At 40 °C At 50 °C Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at at current at at at at
230 V 400 V 500 V 690 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW kW A hp hp hp hp
Operational voltage 200 ... 690 V
6

113 30 55 75 110 101 30 30 75 100 3RW5534-@HA@6 1 1 unit 42S


143 37 75 90 132 128 40 40 100 125 3RW5535-@HA@6 1 1 unit 42S
171 45 90 110 160 153 50 50 100 150 3RW5536-@HA@6 1 1 unit 42S
210 55 110 132 200 186 60 60 150 150 3RW5543-@HA@6 1 1 unit 42S
250 75 132 160 250 220 60 75 150 200 3RW5544-@HA@6 1 1 unit 42S
315 90 160 200 315 279 75 100 200 250 3RW5545-@HA@6 1 1 unit 42S
370 110 200 250 355 328 100 125 250 300 3RW5546-@HA@6 1 1 unit 42S
470 132 250 315 400 416 150 150 350 450 3RW5547-@HA@6 1 1 unit 42S
570 160 315 355 560 504 150 200 400 500 3RW5548-@HA@6 1 1 unit 42S
630 200 355 400 630 561 200 200 450 600 3RW5552-@HA@6 1 1 unit 42S
720 200 400 500 710 641 200 250 500 700 3RW5553-@HA@6 1 1 unit 42S
840 250 450 560 800 748 250 300 600 800 3RW5554-@HA@6 1 1 unit 42S
1 100 315 560 710 1 000 979 350 400 850 1 100 3RW5556-@HA@6 1 1 unit 42S
1 280 400 710 900 1 200 1 139 400 450 1 000 1 250 3RW5558-@HA@6 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


6/32 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
IE3 ready IE4 ready IE3/IE4 ready 3RW55 soft starters > Inside-delta circuit

■ Selection and ordering data


For normal starting (CLASS 10E)

3RW551. 3RW552.
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp

6
Operational voltage 200 ... 480 V
22.5 5.5 11 -- 19.9 5 5 10 -- 3RW5513-@HA@4 1 1 unit 42S
31.5 7.5 15 -- 28 7.5 7.5 20 -- 3RW5514-@HA@4 1 1 unit 42S
43.3 11 18.5 -- 39 10 10 25 -- 3RW5515-@HA@4 1 1 unit 42S
55.4 15 22 -- 49 15 15 30 -- 3RW5516-@HA@4 1 1 unit 42S
65.8 18.5 30 -- 58 15 20 40 -- 3RW5517-@HA@4 1 1 unit 42S
81.4 22 45 -- 72 20 25 50 -- 3RW5524-@HA@4 1 1 unit 42S
109 30 55 -- 96 30 30 75 -- 3RW5525-@HA@4 1 1 unit 42S
133 37 75 -- 118 30 40 75 -- 3RW5526-@HA@4 1 1 unit 42S
161 45 90 -- 143 40 50 100 -- 3RW5527-@HA@4 1 1 unit 42S

Type of electrical connection for the control circuit


Screw terminals 1
Spring-loaded terminals 3

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/33
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > Inside-delta circuit IE3 ready IE4 ready IE3/IE4 ready

For normal starting (CLASS 10E)

3RW553. 3RW554. 3RW555.


At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 480 V
6

196 55 110 -- 175 50 60 125 -- 3RW5534-@HA@4 1 1 unit 42S


248 75 132 -- 222 75 75 150 -- 3RW5535-@HA@4 1 1 unit 42S
296 90 160 -- 265 75 100 200 -- 3RW5536-@HA@4 1 1 unit 42S
364 110 200 -- 322 100 125 250 -- 3RW5543-@HA@4 1 1 unit 42S
433 132 250 -- 381 125 150 300 -- 3RW5544-@HA@4 1 1 unit 42S
546 160 315 -- 483 150 200 400 -- 3RW5545-@HA@4 1 1 unit 42S
641 200 355 -- 568 200 200 450 -- 3RW5546-@HA@4 1 1 unit 42S
814 250 400 -- 721 250 250 600 -- 3RW5547-@HA@4 1 1 unit 42S
987 315 560 -- 873 300 350 750 -- 3RW5548-@HA@4 1 1 unit 42S
1 091 355 630 -- 972 350 400 850 -- 3RW5552-@HA@4 1 1 unit 42S
1 247 400 710 -- 1 110 400 450 950 -- 3RW5553-@HA@4 1 1 unit 42S
1 454 450 800 -- 1 295 450 550 1 150 -- 3RW5554-@HA@4 1 1 unit 42S
1 905 560 1 000 -- 1 695 600 700 1 500 -- 3RW5556-@HA@4 1 1 unit 42S
2 217 710 1 200 -- 1 973 700 850 1 700 -- 3RW5558-@HA@4 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


6/34 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
IE3 ready IE4 ready IE3/IE4 ready 3RW55 soft starters > Inside-delta circuit
For normal starting (CLASS 10E)

3RW551. 3RW552.
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 600 V
22.5 5.5 11 15 19.9 5 5 10 15 3RW5513-@HA@5 1 1 unit 42S
31.5 7.5 15 18.5 28 7.5 7.5 20 25 3RW5514-@HA@5 1 1 unit 42S

6
43.3 11 18.5 22 39 10 10 25 30 3RW5515-@HA@5 1 1 unit 42S
55.4 15 22 30 49 15 15 30 40 3RW5516-@HA@5 1 1 unit 42S
65.8 18.5 30 37 58 15 20 40 50 3RW5517-@HA@5 1 1 unit 42S
43.3 11 18.5 22 39 10 10 25 30 3RW5521-@HA@6 1 1 unit 42S
81.4 22 45 45 72 20 25 50 60 3RW5524-@HA@6 1 1 unit 42S
109 30 55 55 96 30 30 75 75 3RW5525-@HA@6 1 1 unit 42S
133 37 75 90 118 30 40 75 100 3RW5526-@HA@6 1 1 unit 42S
161 45 90 110 143 40 50 100 125 3RW5527-@HA@6 1 1 unit 42S

Type of electrical connection for the control circuit


Screw terminals 1
Spring-loaded terminals 3

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/35
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > Inside-delta circuit IE3 ready IE4 ready IE3/IE4 ready

For normal starting (CLASS 10E)

3RW553. 3RW554. 3RW555.


At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 600 V
6

196 55 110 132 175 50 60 125 150 3RW5534-@HA@6 1 1 unit 42S


248 75 132 160 222 75 75 150 200 3RW5535-@HA@6 1 1 unit 42S
296 90 160 200 265 75 100 200 250 3RW5536-@HA@6 1 1 unit 42S
364 110 200 250 322 100 125 250 300 3RW5543-@HA@6 1 1 unit 42S
433 132 250 315 381 125 150 300 350 3RW5544-@HA@6 1 1 unit 42S
546 160 315 355 483 150 200 400 500 3RW5545-@HA@6 1 1 unit 42S
641 200 355 450 568 200 200 450 600 3RW5546-@HA@6 1 1 unit 42S
814 250 400 500 721 250 250 600 800 3RW5547-@HA@6 1 1 unit 42S
987 315 560 630 873 300 350 750 950 3RW5548-@HA@6 1 1 unit 42S
1 091 355 630 710 972 350 400 850 1 050 3RW5552-@HA@6 1 1 unit 42S
1 247 400 710 800 1 110 400 450 950 1 250 3RW5553-@HA@6 1 1 unit 42S
1 454 450 800 900 1 295 450 550 1 150 1 450 3RW5554-@HA@6 1 1 unit 42S
1 905 560 1 000 1 200 1 695 600 700 1 500 1 900 3RW5556-@HA@6 1 1 unit 42S
2 217 710 1 200 1 500 1 973 700 850 1 700 2 200 3RW5558-@HA@6 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


6/36 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > Accessories

■ Selection and ordering data


Product Manufacturer's Product Application Article No. Price PU PS* PG
designation article number of version per PU (UNIT,
the soft starter SET, M)

Fan covers
Fan cover 3RW551 (1x), -- -- 3RW5983-0FC00 1 1 unit 42S
3RW552 (2x),
3RW553 (2x)
3RW554 (1x) -- -- 3RW5984-0FC00 1 1 unit 42S
3RW5983-0FC00 3RW555 (3x) -- -- 3RW5985-0FC00 1 1 unit 42S
Terminal covers
Terminal 3RW552 (2x), -- -- 3RW5983-0TC20 1 1 unit 42S
cover 3RW553 (2x)

3RW5983-0TC20
3RW554 (2x) -- -- 3RW5984-0TC20 1 1 unit 42S

6
3RW5984-0TC20
Enclosure components
Hinged cover 3RW55 Without -- 3RW5950-0GL20 1 1 unit 42S
cutout

3RW5950-0GL20
Communications modules
Communica- 3RW55 PROFINET -- 3RW5950-0CH00 1 1 unit 42S
tions High-Feature
module1) with integral
switch
PROFINET -- 3RW5980-0CS00 1 1 unit 42S
Standard
PROFIBUS -- 3RW5980-0CP00 1 1 unit 42S

3RW5980-0CS00
EtherNet/IP -- 3RW5980-0CE00 1 1 unit 42S

3RW5980-0CE00
Modbus RTU -- 3RW5980-0CR00 1 1 unit 42S
Modbus TCP -- 3RW5980-0CT00 1 1 unit 42S

3RW5980-0CR00
1) Use the recommended connection plugs for attaching the bus connecting
cable (e.g. angled or suitable for industrial use), see Equipment Manual for
the relevant communications module.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/37
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 soft starters > Accessories

Product Manufacturer's Product Application Article No. Price PU PS* PG


designation article number of version per PU (UNIT,
the soft starter SET, M)

HMI modules
IP65 door 3RW55 IP65 For 3RW5980-0HD00 1 1 unit 42S
mounting kit HMI modules
for HMI
modules

3RW5980-0HD00
Connecting cables
HMI 3RW55 5 m, round For 3RW5980-0HC60 1 1 unit 42S
connecting 2.5 m, round door 3UF7933-0BA00-0 1 1 unit 42J
cable mounting
3UF793.-0BA00-0 1.0 m, round 3UF7937-0BA00-0 1 1 unit 42J
0.5 m, round 3UF7932-0BA00-0 1 1 unit 42J
Further accessories
Push-in lugs -- Two lugs are For 3ZY1311-0AA00 1 10 units 41L
6

for wall required per HMI modules


mounting device and commu-
nications
modules
3ZY1311-0AA00
Blank labels
Unit labeling -- 20 mm x For SIRIUS 3RT2900-1SB20 100 340 41B
plates1) 7 mm, devices units
titanium gray
IC01_00181

3RT2900-1SB20
1) PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


6/38 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter SIRIUS Soft Starter ES (TIA Portal), see page 6/9 or
Industry Mall, see www.siemens.com/product?3RW55Failsafe https://support.industry.siemens.com/cs/ww/en/ps/24230/dl
TIA Selection Tool Cloud (TST Cloud), see Decision-making support for motor starting – Starting and running three-phase
www.siemens.com/tstcloud/?node=3rw55 asynchronous motors efficiently, see www.siemens.com/motorstart-guide
Industry Online Support (SIOS) topic page, see SIRIUS Sim, see page 6/10 or
https://support.industry.siemens.com/cs/ww/en/view/109747404 https://support.industry.siemens.com/cs/ww/en/view/109763750
Simulation Tool for Soft Starters (STS), see page 6/9 or Conversion tool, see www.siemens.com/conversion-tool
https://support.industry.siemens.com/cs/ww/en/view/101494917

Equipped with the utmost functionality, the SIRIUS 3RW55


Failsafe High Performance soft starters confidently handle even
difficult starting and stopping operations. Thanks to innovative
torque control, the device can be used for drives with an output
of between 5.5 kW and 560 kW (at 400 V).
Video: Animation 3RW5 Failsafe soft starter The innovative 3RW55 Failsafe soft starter features an
integrated fail-safe digital input for directly connecting the
EMERGENCY STOP, and thus covers SIL 1 STO applications.
The HMI (with color display, local interface and a slot for
micro SD memory card) and plug-in communications modules
(PROFINET, PROFIBUS, EtherNet/IP and Modbus) ensure

6
maximum flexibility.
With their modern hybrid switching technology, the 3RW55
Failsafe soft starters offer efficient switching for long-term,
energy-saving use.

SIRIUS 3RW55 Failsafe soft starters device family

5 1 3RW55 Failsafe soft starter

2 Communications modules
3 Hinged cover
4 Fan covers
5 Terminal covers (size 2 to size 4)

1 6 HMI push-in lugs for wall mounting

6 7 HMI IP65 door mounting kit


8 HMI soft starter connecting cable

7
IC01_00690c

2 4

SIRIUS 3RW55 Failsafe High Performance soft starter with accessories (see page 6/53)

Siemens IC 10 · 2023 6/39


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data

■ Benefits
6

Product characteristics/function Performance features/benefits

Automatic parameterization Extremely easy commissioning and reliability even under changing
load conditions

Hybrid switching technology and 3-phase motor control Minimum power loss and optimum/symmetrical motor control

TIA integration – communications modules optional Efficient configuration and maximum flexibility in automation engineering

Removable HMI with color display, local interface, slot for Maximum flexibility with regard to user interface and intuitive menu guidance
micro SD memory card

Pump stop and torque control Reduced mechanical loading and optimum pump stop control

Certified according to ATEX/IECEx directive Suitable for the starting of explosion-proof motors

Fail-safe disconnection up to SIL 3/PL e/STO Reduced costs and space requirements thanks to direct wiring of the
EMERGENCY STOP mushroom pushbutton to the soft starter for SIL 1/PL c

System redundancy S2 Simple and straight-forward integration into fault-tolerant automation systems

Direct integration into MindSphere via the OPC UA server Worldwide data availability for optimal plant operation

6/40 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data

■ Technical specifications
More information
Technical specifications, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/25776/faq
https://support.industry.siemens.com/cs/ww/en/ps/25776/td Simulation Tool for Soft Starters (STS), see page 6/9 or
Equipment Manual, see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/109753752

Type 3RW551.-.HF.4 3RW552.-.HF.4 3RW554.-.HF.4


3RW553.-.HF.4
Installation/fixing/dimensions
Width x height x depth H mm 170 x 275 x 152 185 x 306 x 203 210 x 393 x 203

D
W

Type of mounting Screw fixing


Mounting position Vertical (can be rotated +/- 90° and tilted +/- 22.5° forward or backward)
Distance to be maintained with side-by-side mounting
• Above mm 100
• At the side mm 5

6
• Below mm 75
Installation altitude at height above sea level, maximum1) m 2 000
Degree of protection IP on the front according to IEC 60529 IP20 IP00 (IP20 with cover)
Touch protection on the front according to IEC 60529 Finger-safe for vertical Finger-safe for vertical touching from the front
touching from the front with cover
Ambient conditions
Ambient temperature
• During operation2) °C -25 ... +60
• During storage and transport °C -40 ... +80
Environmental category according to IEC 60721
• During operation 3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist),
3S2 (sand must not get into the devices), 3M6
• During storage 1K6 (only occasional condensation), 1C2 (no salt mist),
1S2 (sand must not get into the devices), 1M4
• During transport 2K2, 2C1, 2S1, 2M2 (max. height of fall 0.3 m)
1) Derating from 1 000 m, see characteristic curve on page 6/8. 2) Note derating above 40 °C.

Type 3RW55..-.HF04 3RW55..-.HF14


Control circuit/control
Control supply voltage
• At AC/DC V 24/24 --/--
• At AC V -- 110 ... 250
Relative negative tolerance/relative positive tolerance of the
control supply voltage
• At AC % -20/20 -15/10
• At DC % -20/20 --/--
Frequency of the control supply voltage Hz 50 ... 60
• Relative negative tolerance/relative positive tolerance % -10/10
Type of overvoltage protection Varistors
Type of short-circuit protection for control circuit1) Fuse 4 A gG (Icu =1 kA), fuse 6 A quick-response (Icu =1 kA),
MCB C1 (Icu = 600 A), MCB C6 (Icu = 300 A)
1)
Not included in scope of supply.

Type 3RW55..-.HF.4
Power electronics
Operational voltage V 200 ... 480
• Relative negative tolerance/relative positive tolerance % -15/10
Operational voltage for inside-delta circuit V 200 ... 480
• Relative negative tolerance/relative positive tolerance % -15/10
Operating frequency Hz 50 ... 60
• Relative negative tolerance/relative positive tolerance % -10/10
Minimum load [% of IM]1) % 10
Maximum cable length between soft starter and motor m 800
1)
Relative to set Ie.

Siemens IC 10 · 2023 6/41


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data

Type 3RW5513 3RW5514 10


3RW5515 3RW5516 3RW5517
Rated operational current Ie A 13 18 25 32 38
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 25/22.3/19.6 38/33.5/30.5
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 32/28.4/26 38/33.5/30.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43 43 43
- Start-up time 10 s 1/h 18 18 18 18 18
• 350% IM
- Start-up time 5 s 1/h 28 28 28 28 28
- Start-up time 10 s 1/h 10 10 10 10 10
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 32/28.4/26 38/33.5/30.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 21 21 21
- Start-up time 20 s 1/h 8 8 8 8 8
6

• 350% IM
- Start-up time 10 s 1/h 13 13 13 13 13
- Start-up time 20 s 1/h 4 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 29.6/27.2/23.6 33.5/30.5/27.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 26/23.6/21.2 29/26/23
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 30 s 1/h 7 7 7 7 7
- Start-up time 60 s 1/h 3 3 3 3 3
• 350% IM
- Start-up time 30 s 1/h 4 4 4 4 4
- Start-up time 60 s 1/h 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 2.5/13 3.5/18 5/25 6.5/32 7.5/38
• Minimum/maximum in inside-delta circuits A 4.3/22.5 6.1/31.1 8.7/43.3 11.3/55.4 13/65.8

6/42 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data

Type 3RW5524 3RW5525 3RW5526 3RW5527


Rated operational current Ie A 47 63 77 93
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43 43
- Start-up time 10 s 1/h 18 18 18 18
• 350% IM
- Start-up time 5 s 1/h 28 28 28 28
- Start-up time 10 s 1/h 10 10 10 10
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 21 21
- Start-up time 20 s 1/h 8 8 8 8

6
• 350% IM
- Start-up time 10 s 1/h 13 13 13 13
- Start-up time 20 s 1/h 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7
- Start-up time 40 s 1/h 2.5 0 0 0
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 43.4/38/34.4 53/48/43 68/62/56 82.5/75.5/65
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 30 s 1/h 7 7 7 7
- Start-up time 60 s 1/h 3 3 3 3
• 350% IM
- Start-up time 30 s 1/h 4 4 4 4
- Start-up time 60 s 1/h 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 10/47 13/63 16/77 19/93
• Minimum/maximum in inside-delta circuits A 17.3/81.4 22.5/109 27.7/133 32.9/161

Siemens IC 10 · 2023 6/43


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data

Type 3RW5534 3RW5535 3RW5536


Rated operational current Ie A 113 143 171
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 113/101/89 143/128/118 171/153/141
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 35
- Start-up time 10 s 1/h 18 18 13
• 350% IM
- Start-up time 5 s 1/h 28 17 10
- Start-up time 10 s 1/h 10 4 0
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 14
- Start-up time 20 s 1/h 8 7 4
6

• 350% IM
- Start-up time 10 s 1/h 13 4 0
- Start-up time 20 s 1/h 4 0 0
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 109/97/85 128/113/103 141/129/117
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10
- Start-up time 40 s 1/h 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 6 6
- Start-up time 40 s 1/h 0 0 0
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 89/81/74 108/98/88 117/105/93
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 30 s 1/h 7 7 7
- Start-up time 60 s 1/h 3 3 3
• 350% IM
- Start-up time 30 s 1/h 4 4 4
- Start-up time 60 s 1/h 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 23/113 29/143 34/171
• Minimum/maximum in inside-delta circuits A 39.8/195 50.2/247 58.9/296

6/44 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data

Type 3RW5543 3RW5544 3RW5545 3RW5546 3RW5547 10


3RW5548
Rated operational current Ie A 210 250 315 370 470 570
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 38 43 32 13
- Start-up time 10 s 1/h 13 18 14 18 13 3
• 350% IM
- Start-up time 5 s 1/h 14 28 19 28 19 4
- Start-up time 10 s 1/h 0 10 5 10 6 0.4
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 551/490/445
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 13 21 14 20 13 5
- Start-up time 20 s 1/h 2 8 4 8 3 --

6
• 350% IM
- Start-up time 10 s 1/h 0 13 5 12 6 1
- Start-up time 20 s 1/h 0 4 0 3 0.4 --
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 162/146/130 200/180/160 231/207/183 258/230/202 272/254/236 284/262/240
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 2 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 138/122/106 160/140/120 183/159/135 202/174/160 210/190/170 220/200/180
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 30 s 1/h 7 7 7 7 7 7
- Start-up time 60 s 1/h 3 3 3 3 3 3
• 350% IM
- Start-up time 30 s 1/h 4 4 4 4 4 4
- Start-up time 60 s 1/h 1.8 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 42/210 50/250 63/315 74/370 94/470 114/570
• Minimum/maximum in inside-delta circuits A 72.7/363 86.6/433 109.1/545 128.2/640 162.8/814 197.5/987

Siemens IC 10 · 2023 6/45


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data
Motor feeders according to IEC with 3RV2 motor starter protectors/3VA circuit breakers (without semiconductor protection)
Type of coordination "1", CLASS 10,
short-circuit breaking capacity Iq in kA, see table
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

Q1 Q1

Q11 Q11
NSB0_01902

IC01_00544
M M
3~ 3~

Soft starters Motor starter protectors/circuit breakers Motor starter protectors/circuit breakers
for 400 V systems for 480 V systems for 400 V systems for 480 V systems
Q11 Q1 Iq Q1 Iq Q1 Iq Q1 Iq
Type Type kA Type kA Type kA Type kA
Type of Standard (inline) circuit Inside-delta circuit
6

ToC
coordination 1
"1"
3RW5513 3RV2032-4TA10 65 3RV2032-4TA10 18 3RV2032-4DA10 65 3RV2032-4DA10 18
3RW5514 3RV2032-4DA10 65 3RV2032-4DA10 15 3RV2032-4EA10 65 3RV2032-4EA10 15
3RW5515 3RV2032-4EA10 65 3RV2032-4EA10 15 3RV2032-4VA10 65 3RV2032-4VA10 15
3RW5516 3RV2032-4VA10 65 3RV2032-4VA10 10 3RV2032-4JA10 65 3RV2032-4JA10 10
3RW5517 3RV2032-4WA10 65 3RV2032-4WA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5524 3RV2032-4JA10 65 3RV2032-4JA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5525 3VA2163-7MN32-0AA0 65 3VA2163-7MN32-0AA0 20 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20
3RW5526 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20 3VA2216-7MN32-0AA0 65 3VA2216-7MN32-0AA0 20
3RW5527 3VA2216-7MN32-0AA0 15 3VA2216-7MN32-0AA0 10 3VA2220-7MN32-0AA0 15 3VA2220-7MN32-0AA0 10
3RW5534 3VA2216-7MN32-0AA0 65 -- -- 3VA2220-7MN32-0AA0 65 -- --
3RW5535 3VA2220-7MN32-0AA0 65 -- -- 3VA2325-7MN32-0AA0 65 -- --
3RW5536 3VA2325-7MN32-0AA0 30 3VA2325-7MN32-0AA0 10 3VA2440-7MN32-0AA0 30 3VA2440-7MN32-0AA0 10
3RW5543 3VA2325-7MN32-0AA0 65 3VA2325-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5544 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65
3RW5545 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5546 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5547 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
3RW5548 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65

Note:
The service factor and measurement inaccuracies, for example,
have been taken into account for the selection of the specified
motor starter protectors/circuit breakers; the specified short-
circuit breaking capacities Iq in kA are covered by combination
tests. Smaller motor starter protectors/circuit breakers from the
same series can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must match
the connected three-phase motor, the short-circuit and overload
requirements of the application, and the line protection for the
cables used.

6/46 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data
Motor feeders according to IEC with 3NA3 fuses
gG class full-range fuses for cable and line protection according
to IEC 60269-2, without semiconductor protection
Type of coordination "1",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1 F1 F1

Q21 Q21 Q21

Q11 Q11 Q11

IC01_00545a
NSB0_01904

IC01_00565
M M M
3~ 3~ 3~

Soft starters gG class fuse Line contactor (optional) gG class fuse Line contactor (optional)
for systems for systems for systems for systems for systems

6
up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V
in the supply cable in the delta
Q11 F1 Q21 F1 Q21 Q21
Type Type Type Type Type Type
Type of ToC Standard (inline) circuit Inside-delta circuit
coordination 1
"1"
3RW5513 3NA3820-6 3RT2025 3NA3820-6 3RT2027 3RT2025
3RW5514 3NA3820-6 3RT2026 3NA3820-6 3RT2027 3RT2026
3RW5515 3NA3822-6 3RT2027 3NA3822-6 3RT2036 3RT2027
3RW5516 3NA3824-6 3RT2035 3NA3824-6 3RT2037 3RT2035
3RW5517 3NA3824-6 3RT2035 3NA3824-6 3RT2038 3RT2035
3RW5524 3NA3824-6 3RT2036 3NA3824-6 3RT2046 3RT2036
3RW5525 3NA3830-6 3RT2037 3NA3830-6 3RT2047 3RT2037
3RW5526 3NA3132-6 3RT2038 3NA3132-6 3RT1055 3RT2038
3RW5527 3NA3136-6 3RT2046 3NA3136-6 3RT1056 3RT2046
3RW5534 3NA3244-6 3RT1054 3NA3244-6 3RT1064 3RT1054
3RW5535 3NA3244-6 3RT1055 3NA3244-6 3RT1065 3RT1055
3RW5536 3NA3365-6 3RT1056 3NA3365-6 3RT1066 3RT1056
3RW5543 2 x 3NA3354-6 3RT1064 2 x 3NA3354-6 3RT1075 3RT1064
3RW5544 2 x 3NA3354-6 3RT1065 2 x 3NA3354-6 3RT1076 3RT1065
3RW5545 2 x 3NA3365-6 3RT1075 2 x 3NA3365-6 3TF68 3RT1075
3RW5546 2 x 3NA3365-6 3RT1075 2 x 3NA3365-6 3TF69 3RT1075
3RW5547 2 x 3NA3365-6 3RT1076 2 x 3NA3365-6 3TF69 3RT1076
3RW5548 2 x 3NA3365-6 3TF68 2 x 3NA3365-6 -- 3TF68

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.

Siemens IC 10 · 2023 6/47


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data
Motor feeders according to IEC with 3NE1 SITOR fuses
gR/gS class full-range fuses for semiconductor protection,
cable and line protection (gS)
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F’1

Q21

Q11
NSB0_01905

M
3~

Soft starters gR/gS class fuse Line contactor (optional)


for systems for systems
6

up to 480 V up to 480 V
Q11 F’1 Q21
Type Type Type
Type of ToC Standard (inline) circuit
coordination 2
"2"
3RW5513 3NE1815-0 3RT2025
3RW5514 3NE1802-0 3RT2026
3RW5515 3NE1817-0 3RT2027
3RW5516 3NE1818-0 3RT2035
3RW5517 3NE1820-0 3RT2035
3RW5524 3NE1021-2 3RT2036
3RW5525 3NE1022-0 3RT2037
3RW5526 3NE1224-0 3RT2038
3RW5527 3NE1224-0 3RT2046
3RW5534 3NE1225-0 3RT1054
3RW5535 3NE1227-0 3RT1055
3RW5536 3NE1230-0 3RT1056
3RW5543 3NE1230-2 3RT1064
3RW5544 3NE1331-0 3RT1065
3RW5545 3NE1334-2 3RT1075
3RW5546 3NE1334-2 3RT1075
3RW5547 3NE1436-2 3RT1076
3RW5548 3NE1437-2 3TF68

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.
In inside-delta circuits, a gR/gS class full-range fuse could not
provide the semiconductor protection of the delta-connected
soft starter with a short-circuit breaking capacity that is
adequate for practical use. In this case, we recommend using
aR class partial-range fuses for semiconductor protection for
type of coordination "2" (see page 6/49).

6/48 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data
Motor feeders according to IEC with 3NE8/3NE3/3NC3 fuses
aR class partial-range fuses for semiconductor protection
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1 F1 F1

Q21 Q21 Q21

F3 F3 F3

Q11 Q11 Q11

IC01_00546a
NSB0_01906

IC01_00566
M M M
3~ 3~ 3~

Soft starters gG class fuse aR class fuse Line contactor (optional) gG class fuse aR class fuse Line contactor (optional)
for systems for systems for systems for systems for systems for systems for systems

6
up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V
in the supply in the delta
cable
Q11 F1 F3 Q21 F1 F3 Q21 Q21
Type Type Type Type Type Type Type Type
Type of ToC Standard (inline) circuit Inside-delta circuit
coordination 2
"2"
3RW5513 3NA3820-6 3NE8017-1 3RT2025 3NA3820-6 3NE8017-1 3RT2027 3RT2025
3RW5514 3NA3820-6 3NE8020-1 3RT2026 3NA3820-6 3NE8020-1 3RT2027 3RT2026
3RW5515 3NA3822-6 3NE8021-1 3RT2027 3NA3822-6 3NE8021-1 3RT2036 3RT2027
3RW5516 3NA3824-6 3NE8022-1 3RT2035 3NA3824-6 3NE8022-1 3RT2037 3RT2035
3RW5517 3NA3824-6 3NE8024-1 3RT2035 3NA3824-6 3NE8024-1 3RT2038 3RT2035
3RW5524 3NA3824-6 3NE8024-1 3RT2036 3NA3824-6 3NE8024-1 3RT2046 3RT2036
3RW5525 3NA3830-6 3NE3227 3RT2037 3NA3830-6 3NE3227 3RT2047 3RT2037
3RW5526 3NA3132-6 3NE3227 3RT2038 3NA3132-6 3NE3227 3RT1055 3RT2038
3RW5527 3NA3136-6 3NE3227 3RT2046 3NA3136-6 3NE3227 3RT1056 3RT2046
3RW5534 3NA3244-6 3NE3231 3RT1054 3NA3244-6 3NE3231 3RT1064 3RT1054
3RW5535 3NA3244-6 3NE3233 3RT1055 3NA3244-6 3NE3233 3RT1065 3RT1055
3RW5536 3NA3365-6 3NE3334-0B 3RT1056 3NA3365-6 3NE3334-0B 3RT1066 3RT1056
3RW5543 2 x 3NA3354-6 3NE3333 3RT1064 2 x 3NA3354-6 3NE3333 3RT1075 3RT1064
3RW5544 2 x 3NA3354-6 3NE3335 3RT1065 2 x 3NA3354-6 3NE3335 3RT1076 3RT1065
3RW5545 2 x 3NA3365-6 -- 3RT1075 2 x 3NA3365-6 -- 3TF68 3RT1075
3RW5546 2 x 3NA3365-6 -- 3RT1075 2 x 3NA3365-6 -- 3TF69 3RT1075
3RW5547 2 x 3NA3365-6 3NE3340-8 3RT1076 2 x 3NA3365-6 3NE3340-8 3TF69 3RT1076
3RW5548 2 x 3NA3365-6 3NC3342-1U 3TF68 2 x 3NA3365-6 3NC3342-1U -- 3TF68

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.
For CLASS 10 applications, as an alternative to the gG class
full-range fuses for cable and line protection 3NA3 (F1), 3RV2
motor starter protectors/3VA circuit breakers can also be used,
possibly with reduced short-circuit breaking capacity
(see page 6/46). In these cases, optional line contactors
can be dispensed with.

Siemens IC 10 · 2023 6/49


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > General data
Reversing operation with reversing contactors
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.
(Example circuit, see
3RW55 Equipment Manual, Appendix A.3)
Soft starters Reversing contactor assembly Reversing contactor
for systems up to 480 V for systems up to 480 V
Q11 Q21/Q22 Q21/Q22
Type Type Type
3RW5513 3RA2325 3RT2025
3RW5514 3RA2326 3RT2026
3RW5515 3RA2327 3RT2027
3RW5516 3RA2335 3RT2035
3RW5517 3RA2335 3RT2035
3RW5524 3RA2336 3RT2036
3RW5525 3RA2337 3RT2037
3RW5526 3RA2338 3RT2038
3RW5527 3RA2346 3RT2046
3RW5534 -- 3RT1054
3RW5535 -- 3RT1055
3RW5536 -- 3RT1056
6

3RW5543 -- 3RT1064
3RW5544 -- 3RT1065
3RW5545 -- 3RT1075
3RW5546 -- 3RT1075
3RW5547 -- 3RT1076
3RW5548 -- 3TF68

Redundant contactors for applications > SIL 1


A redundant contactor is necessary for applications with Note:
a Safety Integrity Level > SIL 1 or a Performance Level > PL c
in conjunction with the 3RW55 Failsafe soft starter. For more details about safe switching according to
IEC 62061 (SIL) or ISO 13849-1 (PL) see FAQ article.

F1 F1

Q11 Q11

Q21 Q21
IC01_00790

IC01_00791

M M
3~ 3~

Soft starters Standard (inline) circuit Inside-delta circuit


for systems up to 480 V for systems up to 480 V
according to IEC 62061 according to ISO 13849-1 according to IEC 62061 according to ISO 13849-1
Q11 Q21 Q21
Type Type Type Type Type
3RW5513 3RT2027 3RT2027 3RT2027 3RT2027
3RW5514 3RT2027 3RT2035 3RT2027 3RT2035
3RW5515 3RT2035 3RT2036 3RT2035 3RT2036
3RW5516 3RT2036 3RT2037 3RT2036 3RT2037
3RW5517 3RT2037 3RT2038 3RT2037 3RT2038
3RW5524 3RT2038 3RT2046 3RT2038 3RT2046
3RW5525 3RT2046 3RT1055 3RT2046 3RT1055
3RW5526 3RT1055 3RT1056 3RT1055 3RT1056
3RW5527 3RT1055 3RT1064 3RT1055 3RT1064
3RW5534 3RT1056 3RT1065 3RT1056 3RT1065
3RW5535 3RT1064 3RT1066 3RT1064 3RT1066
3RW5536 3RT1065 3RT1075 3RT1065 3RT1075
3RW5543 3RT1075 3RT1076 3RT1075 3RT1076
3RW5544 3RT1075 3RT1076 3RT1075 3RT1076
3RW5545 3RT1076 3TF68 3RT1076 3TF68
3RW5546 3TF68 3TF69 3TF68 3TF69
3RW5547 3TF69 -- 3TF69 --
3RW5548 -- -- -- --

6/50 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
IE3 ready IE4 ready IE3/IE4 ready 3RW55 Failsafe soft starters > Standard (inline) circuit

■ Selection and ordering data


For normal starting (CLASS 10E)

3RW551. 3RW552. 3RW553. 3RW554.


At 40 °C At 50 °C Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at current at at at
230 V 400 V 200/208 V 220/230 V 460/480 V
A kW kW A hp hp hp
Operational voltage 200 ... 480 V

6
13 3 5.5 11.5 2 3 7.5 3RW5513-@HF@4 1 1 unit 42S
18 4 7.5 15.9 3 5 10 3RW5514-@HF@4 1 1 unit 42S
25 5.5 11 22.3 5 7.5 15 3RW5515-@HF@4 1 1 unit 42S
32 7.5 15 28.4 7.5 10 20 3RW5516-@HF@4 1 1 unit 42S
38 11 18.5 33.5 10 10 20 3RW5517-@HF@4 1 1 unit 42S
47 11 22 41.6 10 10 30 3RW5524-@HF@4 1 1 unit 42S
63 18.5 30 55.5 15 20 40 3RW5525-@HF@4 1 1 unit 42S
77 22 37 68 20 25 50 3RW5526-@HF@4 1 1 unit 42S
93 22 45 82.5 25 30 60 3RW5527-@HF@4 1 1 unit 42S

Type of electrical connection for the control circuit


Screw terminals 1
Spring-loaded terminals 3

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

At 40 °C At 50 °C Article No. Price PU PS* PG


Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at current at at at
230 V 400 V 200/208 V 220/230 V 460/480 V
A kW kW A hp hp hp
Operational voltage 200 ... 480 V
113 30 55 101 30 30 75 3RW5534-@HF@4 1 1 unit 42S
143 37 75 128 40 40 100 3RW5535-@HF@4 1 1 unit 42S
171 45 90 153 50 50 100 3RW5536-@HF@4 1 1 unit 42S
210 55 110 186 60 60 150 3RW5543-@HF@4 1 1 unit 42S
250 75 132 220 60 75 150 3RW5544-@HF@4 1 1 unit 42S
315 90 160 279 75 100 200 3RW5545-@HF@4 1 1 unit 42S
370 110 200 328 100 125 250 3RW5546-@HF@4 1 1 unit 42S
470 132 250 416 150 150 350 3RW5547-@HF@4 1 1 unit 42S
570 160 315 504 150 200 400 3RW5548-@HF@4 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/51
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > Inside-delta circuit IE3 ready IE4 ready IE3/IE4 ready

■ Selection and ordering data


For normal starting (CLASS 10E)

3RW551. 3RW552. 3RW553. 3RW554.


At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at current at at at
230 V 400 V 200/208 V 220/230 V 460/480 V
A kW kW A hp hp hp
Operational voltage 200 ... 480 V
6

22.5 5.5 11 19.9 5 5 10 3RW5513-@HF@4 1 1 unit 42S


31.5 7.5 15 28 7.5 7.5 20 3RW5514-@HF@4 1 1 unit 42S
43.3 11 18.5 39 10 10 25 3RW5515-@HF@4 1 1 unit 42S
55.4 15 22 49 15 15 30 3RW5516-@HF@4 1 1 unit 42S
65.8 18.5 30 58 15 20 40 3RW5517-@HF@4 1 1 unit 42S
81.4 22 45 72 20 25 50 3RW5524-@HF@4 1 1 unit 42S
109 30 55 96 30 30 75 3RW5525-@HF@4 1 1 unit 42S
133 37 75 118 30 40 75 3RW5526-@HF@4 1 1 unit 42S
161 45 90 143 40 50 100 3RW5527-@HF@4 1 1 unit 42S

Type of electrical connection for the control circuit


Screw terminals 1
Spring-loaded terminals 3

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at current at at at
230 V 400 V 200/208 V 220/230 V 460/480 V
A kW kW A hp hp hp
Operational voltage 200 ... 480 V
196 55 110 175 50 60 125 3RW5534-@HF@4 1 1 unit 42S
248 75 132 222 75 75 150 3RW5535-@HF@4 1 1 unit 42S
296 90 160 265 75 100 200 3RW5536-@HF@4 1 1 unit 42S
364 110 200 322 100 125 250 3RW5543-@HF@4 1 1 unit 42S
433 132 250 381 125 150 300 3RW5544-@HF@4 1 1 unit 42S
546 160 315 483 150 200 400 3RW5545-@HF@4 1 1 unit 42S
641 200 355 568 200 200 450 3RW5546-@HF@4 1 1 unit 42S
814 250 400 721 250 250 600 3RW5547-@HF@4 1 1 unit 42S
987 315 560 873 300 350 750 3RW5548-@HF@4 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6

Control supply voltage


24 V AC/DC 0
110 ... 250 V AC 1

Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


6/52 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > Accessories

■ Selection and ordering data


Product Manufacturer's Product Application Article No. Price PU PS* PG
designation article number of version per PU (UNIT,
the soft starter SET, M)

Fan covers
Fan cover 3RW551 (1x), -- -- 3RW5983-0FC00 1 1 unit 42S
3RW552 (2x),
3RW553 (2x)
3RW554 (1x) -- -- 3RW5984-0FC00 1 1 unit 42S
3RW5983-0FC00
Terminal covers
Terminal 3RW552 (2x), -- -- 3RW5983-0TC20 1 1 unit 42S
cover 3RW553 (2x)

3RW5983-0TC20
3RW554 (2x) -- -- 3RW5984-0TC20 1 1 unit 42S

6
3RW5984-0TC20
Enclosure components
Hinged cover 3RW55 Without -- 3RW5950-0GL20 1 1 unit 42S
cutout

3RW5950-0GL20
Communications modules
Communica- 3RW55 PROFINET -- 3RW5950-0CH00 1 1 unit 42S
tions module1) High-Feature
with integral
switch
PROFINET -- 3RW5980-0CS00 1 1 unit 42S
Standard
PROFIBUS -- 3RW5980-0CP00 1 1 unit 42S

3RW5980-0CS00
EtherNet/IP -- 3RW5980-0CE00 1 1 unit 42S

3RW5980-0CE00
Modbus RTU -- 3RW5980-0CR00 1 1 unit 42S
Modbus TCP -- 3RW5980-0CT00 1 1 unit 42S

3RW5980-0CR00
1) Use the recommended connection plugs for attaching the bus connecting
cable (e.g. angled or suitable for industrial use), see Equipment Manual for
the relevant communications module.
* You can order this quantity or a multiple thereof.
Illustrations are approximate Siemens IC 10 · 2023 6/53
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
High Performance soft starters
3RW55 Failsafe soft starters > Accessories

Product Manufacturer's Product Application Article No. Price PU PS* PG


designation article number of version per PU (UNIT,
the soft starter SET, M)

HMI modules
IP65 door 3RW55 IP65 For 3RW5980-0HD00 1 1 unit 42S
mounting kit HMI modules
for HMI
modules

3RW5980-0HD00
Connecting cables
HMI 3RW55 5 m, round For 3RW5980-0HC60 1 1 unit 42S
connecting 2.5 m, round door 3UF7933-0BA00-0 1 1 unit 42J
cable mounting
3UF793.-0BA00-0 1.0 m, round 3UF7937-0BA00-0 1 1 unit 42J
0.5 m, round 3UF7932-0BA00-0 1 1 unit 42J
Further accessories
Push-in lugs -- Two lugs are For 3ZY1311-0AA00 1 10 units 41L
6

for wall required per HMI modules


mounting device and commu-
nications
modules
3ZY1311-0AA00
Blank labels
Unit labeling -- 20 mm x For 3RT2900-1SB20 100 340 41B
plates1) 7 mm, SIRIUS units
titanium gray devices
IC01_00181

3RT2900-1SB20
1) PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


6/54 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter SIRIUS Soft Starter ES (TIA Portal) for diagnostics, see page 6/9 or
Industry Mall, see www.siemens.com/product?3RW52 https://support.industry.siemens.com/cs/ww/en/ps/24230/dl
TIA Selection Tool Cloud (TST Cloud), see SIRIUS 3RW soft starter block library for SIMATIC PCS 7, see page 6/10 or
www.siemens.com/tstcloud/?node=3rw52 https://support.industry.siemens.com/cs/ww/en/view/109770336
Industry Online Support (SIOS) topic page, see Decision-making support for motor starting – Starting and running three-phase
https://support.industry.siemens.com/cs/ww/en/view/109747404 asynchronous motors efficiently, see www.siemens.com/motorstart-guide
Simulation Tool for Soft Starters (STS), see page 6/9 or Conversion tool, see www.siemens.com/conversion-tool
https://support.industry.siemens.com/cs/ww/en/view/101494917

SIRIUS 3RW52 General Performance soft starters are the ideal


solution for standard applications. With ideal 3-phase motor
control, they cover the performance range from 5.5 to 560 kW
(at 400 V).
Optional HMI modules, plug-in communications modules
(PROFINET, PROFIBUS, EtherNet/IP and Modbus) and either an
analog output or thermistor motor protection ensure maximum
flexibility.
With their modern hybrid switching technology, the
SIRIUS 3RW52 soft starters offer efficient switching for

6
long-term, energy-saving use.

SIRIUS 3RW52 soft starters device family

7
4

2
IC01_00581b

3 5

1 3RW52 soft starter

2 HMI modules 5 Fan covers 8 IP65 door mounting kit


3 Communications modules 6 Terminal covers (size 2 to size 4) 9 HMI soft starter connecting cable
4 Hinged cover 7 Push-in lugs for wall mounting

SIRIUS 3RW52 General Performance soft starter with accessories (see page 6/71), for expansion with HMI module or communications module

Siemens IC 10 · 2023 6/55


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data

■ Benefits
6

Product characteristics/function Performance features/benefits

Hybrid switching technology and 3-phase motor control Minimum power loss and optimum/symmetrical motor control

TIA integration – communications modules and HMI modules optional Efficient configuration and maximum flexibility in automation engineering

Soft Torque Reduced mechanical loading and optimum pump stop

Parameterization using potentiometers Simple and fast commissioning

Wide range for control supply and main voltage Low variance, high system availability even with weak supply networks

6/56 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data

■ Technical specifications
More information
Technical specifications, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/25100/faq
https://support.industry.siemens.com/cs/ww/en/ps/25100/td Simulation Tool for Soft Starters (STS), see page 6/9 or
Equipment Manual, see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/109753751

Type 3RW5213 3RW5216 3RW5224 3RW5226 3RW5243


3RW5214 3RW5217 3RW5225 3RW5227 3RW5244
3RW5215 3RW5234 3RW5245
3RW5235 3RW5246
3RW5236 3RW5247
3RW5248
Installation/fixing/dimensions
Width x height x depth mm 170 x 275 x 152 185 x 306 x 203 210 x 393 x 203
H

Type of mounting Screw fixing


Mounting position For vertical For vertical For vertical For vertical mounting surface
mounting surface mounting surface mounting surface can be rotated +/- 90°,

6
can be rotated can be rotated can be rotated for vertical mounting surface
+/- 10° and tilted +/- 90°, +/- 10° and tilted can be tilted +/- 22.5°
forward or for vertical forward or forward or backward
backward mounting surface backward
can be tilted
+/- 22.5° forward
or backward
Distance to be maintained with side-by-side mounting
• Above mm 100
• At the side mm 5
• Below mm 75
Installation altitude at height above sea level, m 5 000
maximum1)
Degree of protection IP on the front according to IP20 IP00 (IP20 with cover)
IEC 60529
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching Finger-safe for vertical touching from the front
from the front with cover
Ambient conditions
Ambient temperature
• During operation2) °C -25 ... +60
• During storage and transport °C -40 ... +80
Environmental category according to IEC 60721
• During operation 3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist),
3S2 (sand must not get into the devices), 3M6
• During storage 1K6 (only occasional condensation), 1C2 (no salt mist),
1S2 (sand must not get into the devices), 1M4
• During transport 2K2, 2C1, 2S1, 2M2 (max. height of fall 0.3 m)
1) Derating from 1 000 m, see characteristic curve on page 6/8.
2)
Note derating above 40 °C.

Siemens IC 10 · 2023 6/57


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data

Type 3RW52..-..C0. 3RW52..-..C1.


Control circuit/control
Control supply voltage
• At AC/DC V 24/24 --/--
• At AC V -- 110 ... 250
• Relative negative tolerance/relative positive tolerance with AC % -20/20 -15/10
• Relative negative tolerance/relative positive tolerance with DC % -20/20 --/--
Frequency of the control supply voltage Hz 50 ... 60
• Relative negative tolerance/relative positive tolerance % -10/10
Type of overvoltage protection Varistors
Type of short-circuit protection for control circuit1) Fuse 4 A gG (Icu =1 kA), fuse 6 A quick-response (Icu =1 kA),
MCB C1 (Icu = 600 A), MCB C6 (Icu = 300 A)
1)
Not included in scope of supply.

Type 3RW52..-..C.4 3RW52..-..C.5


Power electronics
Operational voltage V 200 ... 480 200 ... 600
• Relative negative tolerance/relative positive tolerance % -15/10
Operational voltage for inside-delta circuit V 200 ... 480 200 ... 600
• Relative negative tolerance/relative positive tolerance % -15/10
6

Operating frequency Hz 50 ... 60


• Relative negative tolerance/relative positive tolerance % -10/10
Minimum load [% of IM]1) % 15
Maximum cable length between soft starter and motor m 800
1)
Relative to the smallest adjustable Ie.

6/58 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data

Type 3RW5213 3RW5214 10


3RW5215 3RW5216 3RW5217
Rated operational current Ie A 13 18 25 32 38
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 32/28.4/26 38/33.5/30.5
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 32/28.4/26 38/33.5/30.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43 43 43
- Start-up time 10 s 1/h 18 18 18 18 18
• 350% IM
- Start-up time 5 s 1/h 28 28 28 28 28
- Start-up time 10 s 1/h 10 10 10 10 10
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 32/28.4/26 38/33.5/30.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 21 21 21
- Start-up time 20 s 1/h 8 8 8 8 8

6
• 350% IM
- Start-up time 10 s 1/h 13 13 13 13 13
- Start-up time 20 s 1/h 4 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 29.6/27.2/23.6 33.5/30.5/27.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Adjustable rated motor current IM
• Minimum/maximum A 5.5/13 7.5/18 11.5/25 14/32 15.5/38
• Minimum/maximum in inside-delta circuits A 9.5/22.5 13/31.2 19.9/43.3 24.2/55.4 26.8/65.8

Siemens IC 10 · 2023 6/59


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data

Type 3RW5224 3RW5225 3RW5226 3RW5227


Rated operational current Ie A 47 63 77 93
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43 43
- Start-up time 10 s 1/h 18 18 18 18
• 350% IM
- Start-up time 5 s 1/h 28 28 28 28
- Start-up time 10 s 1/h 10 10 10 10
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 21 21
- Start-up time 20 s 1/h 8 8 8 8
6

• 350% IM
- Start-up time 10 s 1/h 13 13 13 13
- Start-up time 20 s 1/h 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 47/41.6/36.2 63/55.5/50.5 65/59/53 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10
- Start-up time 40 s 1/h 4 3 4 4
• 350% IM
- Start-up time 20 s 1/h 7 4 7 7
- Start-up time 40 s 1/h 2 0 2.5 2.5
Adjustable rated motor current IM
• Minimum/maximum A 20/47 25.5/63 32/77 40.5/93
• Minimum/maximum in inside-delta circuits A 34.6/81.4 44.2/109 55.4/133 70.1/161

6/60 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data

Type 10
3RW5234 3RW5235 3RW5236
Rated operational current Ie A 113 143 171
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting A 113/101/89 143/128/118 171/153/141
at 40/50/60 °C, AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43
- Start-up time 10 s 1/h 18 18 18
• 350% IM
- Start-up time 5 s 1/h 28 27 20
- Start-up time 10 s 1/h 10 8 4
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 139/127/116 158/146/129
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 21
- Start-up time 20 s 1/h 8 8 8

6
• 350% IM
- Start-up time 10 s 1/h 13 12 12
- Start-up time 20 s 1/h 4 1 1
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 109/97/85 113/103/93 129/117/105
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10
- Start-up time 40 s 1/h 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5
Adjustable rated motor current IM
• Minimum/maximum A 53/113 68/143 81/171
• Minimum/maximum in inside-delta circuits A 91.8/196 118/248 140/296

Siemens IC 10 · 2023 6/61


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data

Type 3RW5243 3RW5244 3RW5245 3RW5246 3RW5247 10


3RW5248
Rated operational current Ie A 210 250 315 370 470 570
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43 43 30 20
- Start-up time 10 s 1/h 18 18 14 18 11 6
• 350% IM
- Start-up time 5 s 1/h 28 28 16 28 17 9
- Start-up time 10 s 1/h 5 10 4 10 5 1
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 197/184/170 250/220/200 279/255/231 370/328/300 398/362/326 460/416/372
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 21 21 21 18
- Start-up time 20 s 1/h 8 8 8 8 8 7
6

• 350% IM
- Start-up time 10 s 1/h 12 13 12 13 13 11
- Start-up time 20 s 1/h 1 4 3 4 4 2
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 162/146/130 200/180/160 195/171/147 258/230/202 272/236/218 284/262/240
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5 2.5
Adjustable rated motor current IM
• Minimum/maximum A 90/210 100/250 135/315 160/370 200/470 240/570
• Minimum/maximum in inside-delta circuits A 156/364 173/433 234/546 277/641 346/814 416/987

6/62 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data
Motor feeders according to IEC with 3RV2 motor starter protectors/3VA circuit breakers (without semiconductor protection)
Type of coordination "1", CLASS 10,
short-circuit breaking capacity Iq in kA, see table
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

Q1 Q1

Q11 Q11
NSB0_01902

IC01_00544
M M
3~ 3~

Soft starters Motor starter protectors/circuit breakers Motor starter protectors/circuit breakers
for 400 V systems for 500 V systems for 400 V systems for 500 V systems
Q11 Q1 Iq Q1 Iq Q1 Iq Q1 Iq
Type Type kA Type kA Type kA Type kA
Type of Standard (inline) circuit Inside-delta circuit

6
ToC
coordination 1
"1"
3RW5213 3RV2032-4TA10 65 3RV2032-4TA10 18 3RV2032-4DA10 65 3RV2032-4DA10 18
3RW5214 3RV2032-4DA10 65 3RV2032-4DA10 15 3RV2032-4EA10 65 3RV2032-4EA10 15
3RW5215 3RV2032-4EA10 65 3RV2032-4EA10 15 3RV2032-4VA10 65 3RV2032-4VA10 15
3RW5216 3RV2032-4VA10 65 3RV2032-4VA10 10 3RV2032-4JA10 65 3RV2032-4JA10 10
3RW5217 3RV2032-4WA10 65 3RV2032-4WA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5224 3RV2032-4JA10 65 3RV2032-4JA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5225 3VA2163-7MN32-0AA0 65 3VA2163-7MN32-0AA0 20 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20
3RW5226 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20 3VA2216-7MN32-0AA0 65 3VA2216-7MN32-0AA0 20
3RW5227 3VA2216-7MN32-0AA0 15 3VA2216-7MN32-0AA0 10 3VA2220-7MN32-0AA0 15 3VA2220-7MN32-0AA0 10
3RW5234 3VA2216-7MN32-0AA0 65 -- -- 3VA2220-7MN32-0AA0 65 -- --
3RW5235 3VA2220-7MN32-0AA0 65 -- -- 3VA2325-7MN32-0AA0 65 -- --
3RW5236 3VA2325-7MN32-0AA0 30 3VA2325-7MN32-0AA0 10 3VA2440-7MN32-0AA0 30 3VA2440-7MN32-0AA0 10
3RW5243 3VA2325-7MN32-0AA0 65 3VA2325-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5244 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65
3RW5245 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5246 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5247 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
3RW5248 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65

Note:
The service factor and measurement inaccuracies, for example,
have been taken into account for the selection of the specified
motor starter protectors/circuit breakers; the specified short-
circuit breaking capacities Iq in kA are covered by combination
tests. Smaller motor starter protectors/circuit breakers from the
same series can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must match
the connected three-phase motor, the short-circuit and overload
requirements of the application, and the line protection for the
cables used.

Siemens IC 10 · 2023 6/63


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data
Motor feeders according to IEC with 3NA3 fuses
gG class full-range fuses for cable and line protection according
to IEC 60269-2, without semiconductor protection
Type of coordination "1",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1 F1 F1

Q21 Q21 Q21

Q11 Q11 Q11

IC01_00545a
NSB0_01904

IC01_00565
M M M
3~ 3~ 3~

Soft starters gG class fuse Line contactor (optional) gG class fuse Line contactor (optional)
for systems for systems for systems for systems for systems for systems for systems for systems
6

up to 600 V up to 480 V up to 600 V up to 600 V up to 480 V up to 600 V up to 480 V up to 600 V


in the supply in the supply in the delta in the delta
cable cable
Q11 F1 Q21 Q21 F1 Q21 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type
Type of ToC Standard (inline) circuit Inside-delta circuit
coordination 1
"1"
3RW5213 3NA3820-6 3RT2025 3RT2025 3NA3820-6 3RT2027 3RT2035 3RT2025 3RT2025
3RW5214 3NA3820-6 3RT2026 3RT2027 3NA3820-6 3RT2027 3RT2037 3RT2026 3RT2027
3RW5215 3NA3822-6 3RT2027 3RT2037 3NA3822-6 3RT2036 3RT2037 3RT2027 3RT2037
3RW5216 3NA3824-6 3RT2035 3RT2037 3NA3824-6 3RT2037 3RT2038 3RT2035 3RT2037
3RW5217 3NA3824-6 3RT2035 3RT2037 3NA3824-6 3RT2038 3RT2046 3RT2035 3RT2037
3RW5224 3NA3824-6 3RT2036 3RT2037 3NA3824-6 3RT2046 3RT2047 3RT2036 3RT2037
3RW5225 3NA3830-6 3RT2037 3RT2046 3NA3830-6 3RT2047 3RT1054 3RT2037 3RT2046
3RW5226 3NA3132-6 3RT2038 3RT2046 3NA3132-6 3RT1055 3RT1055 3RT2038 3RT2046
3RW5227 3NA3136-6 3RT2046 3RT2047 3NA3136-6 3RT1056 3RT1056 3RT2046 3RT2047
3RW5234 3NA3244-6 3RT1054 3RT1054 3NA3244-6 3RT1064 3RT1064 3RT1054 3RT1054
3RW5235 3NA3244-6 3RT1055 3RT1055 3NA3244-6 3RT1065 3RT1065 3RT1055 3RT1055
3RW5236 3NA3365-6 3RT1056 3RT1064 3NA3365-6 3RT1066 3RT1075 3RT1056 3RT1064
3RW5243 2 x 3NA3354-6 3RT1064 3RT1064 2 x 3NA3354-6 3RT1075 3RT1075 3RT1064 3RT1064
3RW5244 2 x 3NA3354-6 3RT1065 3RT1065 2 x 3NA3354-6 3RT1076 3RT1076 3RT1065 3RT1065
3RW5245 2 x 3NA3365-6 3RT1075 3RT1075 2 x 3NA3365-6 3TF68 3TF68 3RT1075 3RT1075
3RW5246 2 x 3NA3365-6 3RT1075 3RT1075 2 x 3NA3365-6 3TF69 3TF69 3RT1075 3RT1075
3RW5247 2 x 3NA3365-6 3RT1076 3RT1276 2 x 3NA3365-6 3TF69 3TF69 3RT1076 3RT1276
3RW5248 2 x 3NA3365-6 3TF68 3TF68 2 x 3NA3365-6 -- -- 3TF68 3TF68

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.

6/64 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data
Motor feeders according to IEC with 3NE1 SITOR fuses
gR/gS class full-range fuses for semiconductor protection,
cable and line protection (gS)
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F’1

Q21

Q11
NSB0_01905

M
3~

Soft starters gR/gS class fuse Line contactor (optional)


for systems for systems for systems

6
up to 600 V up to 480 V up to 600 V
Q11 F’1 Q21 Q21
Type Type Type Type
Type of ToC Standard (inline) circuit
coordination 2
"2"
3RW5213 3NE1815-0 3RT2025 3RT2025
3RW5214 3NE1802-0 3RT2026 3RT2027
3RW5215 3NE1817-0 3RT2027 3RT2037
3RW5216 3NE1818-0 3RT2035 3RT2037
3RW5217 3NE1820-0 3RT2035 3RT2037
3RW5224 3NE1021-2 3RT2036 3RT2037
3RW5225 3NE1022-0 3RT2037 3RT2046
3RW5226 3NE1224-0 3RT2038 3RT2046
3RW5227 3NE1224-0 3RT2046 3RT2047
3RW5234 3NE1225-0 3RT1054 3RT1054
3RW5235 3NE1227-0 3RT1055 3RT1055
3RW5236 3NE1230-0 3RT1056 3RT1064
3RW5243 3NE1230-21) 3RT1064 3RT1064
3RW5244 3NE1331-0 3RT1065 3RT1065
3RW5245 3NE1334-2 3RT1075 3RT1075
3RW5246 3NE1334-2 3RT1075 3RT1075
3RW5247 3NE1436-2 3RT1076 3RT1276
3RW5248 3NE1437-2 3TF68 3TF68
1)
For systems up to 500 V.
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.
In inside-delta circuits, a gR/gS class full-range fuse could not
provide the semiconductor protection of the delta-connected
soft starter with a short-circuit breaking capacity that is
adequate for practical use. In this case, we recommend using
aR class partial-range fuses for semiconductor protection for
type of coordination "2" (see page 6/66).

Siemens IC 10 · 2023 6/65


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > General data
Motor feeders according to IEC with 3NE8/3NE4/3NE3 fuses
aR class partial-range fuses for semiconductor protection
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1 F1 F1

Q21 Q21 Q21

F3 F3 F3

Q11 Q11 Q11


NSB0_01906

IC01_00546a

IC01_00566
M M M
3~ 3~ 3~

Soft starters gG class fuse aR class fuse Line contactor gG class fuse aR class fuse Line contactor (optional)
(optional)
6

for systems for systems for for for systems for systems for systems for systems for for
up to 600 V up to 500 V systems systems up to 600 V up to 600 V up to 480 V up to 600 V systems systems
up to up to in the supply in the supply up to 480 V up to 600 V
480 V 600 V cable cable in the delta in the delta
Q11 F1 F3 Q21 Q21 F1 F3 Q21 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type Type Type
Type of ToC Standard (inline) circuit Inside-delta circuit
coordination 2
"2"
3RW5213 3NA3820-6 3NE8017-1 3RT2025 3RT2025 3NA3820-6 3NE8017-1 3RT2027 3RT2035 3RT2025 3RT2025
3RW5214 3NA3820-6 3NE8020-1 3RT2026 3RT2027 3NA3820-6 3NE8020-1 3RT2027 3RT2037 3RT2026 3RT2027
3RW5215 3NA3822-6 3NE8021-1 3RT2027 3RT2037 3NA3822-6 3NE8021-1 3RT2036 3RT2037 3RT2027 3RT2037
3RW5216 3NA3824-6 3NE8022-1 3RT2035 3RT2037 3NA3824-6 3NE8022-1 3RT2037 3RT2038 3RT2035 3RT2037
3RW5217 3NA3824-6 3NE8024-1 3RT2035 3RT2037 3NA3824-6 3NE8024-1 3RT2038 3RT2046 3RT2035 3RT2037
3RW5224 3NA3824-6 3NE8024-1 3RT2036 3RT2037 3NA3824-6 3NE8024-1 3RT2046 3RT2047 3RT2036 3RT2037
3RW5225 3NA3830-6 3NE8024-1 3RT2037 3RT2046 3NA3830-6 3NE8024-1 3RT2047 3RT1054 3RT2037 3RT2046
3RW5226 3NA3132-6 3NE8024-1 3RT2038 3RT2046 3NA3132-6 3NE8024-1 3RT1055 3RT1055 3RT2038 3RT2046
3RW5227 3NA3136-6 3NE4124 3RT2046 3RT2047 3NA3136-6 3NE4124 3RT1056 3RT1056 3RT2046 3RT2047
3RW5234 3NA3244-6 3NE3332-0B 3RT1054 3RT1054 3NA3244-6 3NE3332-0B 3RT1064 3RT1064 3RT1054 3RT1054
3RW5235 3NA3244-6 3NE3334-0B 3RT1055 3RT1055 3NA3244-6 3NE3334-0B 3RT1065 3RT1065 3RT1055 3RT1055
3RW5236 3NA3365-6 3NE3335 3RT1056 3RT1064 3NA3365-6 3NE3335 3RT1066 3RT1075 3RT1056 3RT1064
3RW5243 2 x 3NA3354-6 3NE3333 3RT1064 3RT1064 2 x 3NA3354-6 3NE3333 3RT1075 3RT1075 3RT1064 3RT1064
3RW5244 2 x 3NA3354-6 3NE3336 3RT1065 3RT1065 2 x 3NA3354-6 3NE3336 3RT1076 3RT1076 3RT1065 3RT1065
3RW5245 2 x 3NA3365-6 3NE3336 3RT1075 3RT1075 2 x 3NA3365-6 3NE3336 3TF68 3TF68 3RT1075 3RT1075
3RW5246 2 x 3NA3365-6 3NE3336 3RT1075 3RT1075 2 x 3NA3365-6 3NE3336 3TF69 3TF69 3RT1075 3RT1075
3RW5247 2 x 3NA3365-6 3NE3340-8 3RT1076 3RT1276 2 x 3NA3365-6 3NE3340-8 3TF69 3TF69 3RT1076 3RT1276
3RW5248 2 x 3NA3365-6 3NE3340-8 3TF68 3TF68 2 x 3NA3365-6 3NE3340-8 -- -- 3TF68 3TF68

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.
For CLASS 10 applications, as an alternative to the gG class
full-range fuses for cable and line protection 3NA3 (F1), 3RV2
motor starter protectors/3VA circuit breakers can also be used,
possibly with reduced short-circuit breaking capacity
(see page 6/63). In these cases, optional line contactors
can be dispensed with.

6/66 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
IE3 ready IE4 ready IE3/IE4 ready 3RW52 soft starters > Standard (inline) circuit

■ Selection and ordering data


For normal starting (CLASS 10A)

3RW521. 3RW522. 3RW523. 3RW524.


At 40 °C At 50 °C Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 480 V
13 3 5.5 -- 11.5 2 3 7.5 -- 3RW5213-@@C@4 1 1 unit 42S

6
18 4 7.5 -- 15.9 3 5 10 -- 3RW5214-@@C@4 1 1 unit 42S
25 5.5 11 -- 22.3 5 7.5 15 -- 3RW5215-@@C@4 1 1 unit 42S
32 7.5 15 -- 28.4 7.5 10 20 -- 3RW5216-@@C@4 1 1 unit 42S
38 11 18.5 -- 33.5 10 10 20 -- 3RW5217-@@C@4 1 1 unit 42S
47 11 22 -- 41.6 10 10 30 -- 3RW5224-@@C@4 1 1 unit 42S
63 18.5 30 -- 55.5 15 20 40 -- 3RW5225-@@C@4 1 1 unit 42S
77 22 37 -- 68 20 25 50 -- 3RW5226-@@C@4 1 1 unit 42S
93 22 45 -- 82.5 25 30 60 -- 3RW5227-@@C@4 1 1 unit 42S

Type of electrical connection for the control circuit


Screw terminals 1
Spring-loaded terminals 3
Product function
Analog output A
Thermistor motor protection T
Control supply voltage
24 V AC/DC 0
110 ... 250 V AC 1
Note:
For the constraints for the motor outputs specified here,
see page 6/8.
At 40 °C At 50 °C Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 480 V
113 30 55 -- 101 30 30 75 -- 3RW5234-@@C@4 1 1 unit 42S
143 37 75 -- 128 40 40 100 -- 3RW5235-@@C@4 1 1 unit 42S
171 45 90 -- 153 50 50 100 -- 3RW5236-@@C@4 1 1 unit 42S
210 55 110 -- 186 60 60 150 -- 3RW5243-@@C@4 1 1 unit 42S
250 75 132 -- 220 60 75 150 -- 3RW5244-@@C@4 1 1 unit 42S
315 90 160 -- 279 75 100 200 -- 3RW5245-@@C@4 1 1 unit 42S
370 110 200 -- 328 100 125 250 -- 3RW5246-@@C@4 1 1 unit 42S
470 132 250 -- 416 150 150 350 -- 3RW5247-@@C@4 1 1 unit 42S
570 160 315 -- 504 150 200 400 -- 3RW5248-@@C@4 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6
Product function
Analog output A
Thermistor motor protection T
Control supply voltage
24 V AC/DC 0
110 ... 250 V AC 1
Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/67
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > Standard (inline) circuit IE3 ready IE4 ready IE3/IE4 ready

For normal starting (CLASS 10A)

3RW521. 3RW522. 3RW523. 3RW524.


At 40 °C At 50 °C Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 600 V
13 3 5.5 7.5 11.5 2 3 7.5 10 3RW5213-@@C@5 1 1 unit 42S
18 4 7.5 11 15.9 3 5 10 10 3RW5214-@@C@5 1 1 unit 42S
25 5.5 11 15 22.3 5 7.5 15 20 3RW5215-@@C@5 1 1 unit 42S
6

32 7.5 15 18.5 28.4 7.5 10 20 25 3RW5216-@@C@5 1 1 unit 42S


38 11 18.5 22 33.5 10 10 20 30 3RW5217-@@C@5 1 1 unit 42S
47 11 22 30 41.6 10 10 30 40 3RW5224-@@C@5 1 1 unit 42S
63 18.5 30 37 55.5 15 20 40 50 3RW5225-@@C@5 1 1 unit 42S
77 22 37 45 68 20 25 50 60 3RW5226-@@C@5 1 1 unit 42S
93 22 45 55 82.5 25 30 60 75 3RW5227-@@C@5 1 1 unit 42S

Type of electrical connection for the control circuit


Screw terminals 1
Spring-loaded terminals 3
Product function
Analog output A
Thermistor motor protection T
Control supply voltage
24 V AC/DC 0
110 ... 250 V AC 1
Note:
For the constraints for the motor outputs specified here,
see page 6/8.
At 40 °C At 50 °C Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 600 V
113 30 55 75 101 30 30 75 100 3RW5234-@@C@5 1 1 unit 42S
143 37 75 90 128 40 40 100 125 3RW5235-@@C@5 1 1 unit 42S
171 45 90 110 153 50 50 100 150 3RW5236-@@C@5 1 1 unit 42S
210 55 110 132 186 60 60 150 150 3RW5243-@@C@5 1 1 unit 42S
250 75 132 160 220 60 75 150 200 3RW5244-@@C@5 1 1 unit 42S
315 90 160 200 279 75 100 200 250 3RW5245-@@C@5 1 1 unit 42S
370 110 200 250 328 100 125 250 300 3RW5246-@@C@5 1 1 unit 42S
470 132 250 315 416 150 150 350 450 3RW5247-@@C@5 1 1 unit 42S
570 160 315 355 504 150 200 400 500 3RW5248-@@C@5 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6
Product function
Analog output A
Thermistor motor protection T
Control supply voltage
24 V AC/DC 0
110 ... 250 V AC 1
Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


6/68 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
IE3 ready IE4 ready IE3/IE4 ready 3RW52 soft starters > Inside-delta circuit

■ Selection and ordering data


For normal starting (CLASS 10A)

3RW521. 3RW522. 3RW523. 3RW524.


At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 480 V
22.5 5.5 11 -- 19.9 5 5 10 -- 3RW5213-@@C@4 1 1 unit 42S

6
31.5 7.5 15 -- 28 7.5 7.5 20 -- 3RW5214-@@C@4 1 1 unit 42S
43.3 11 18.5 -- 39 10 10 25 -- 3RW5215-@@C@4 1 1 unit 42S
55.4 15 22 -- 49 15 15 30 -- 3RW5216-@@C@4 1 1 unit 42S
65.8 18.5 30 -- 58 15 20 40 -- 3RW5217-@@C@4 1 1 unit 42S
81.4 22 45 -- 72 20 25 50 -- 3RW5224-@@C@4 1 1 unit 42S
109 30 55 -- 96 30 30 75 -- 3RW5225-@@C@4 1 1 unit 42S
133 37 75 -- 118 30 40 75 -- 3RW5226-@@C@4 1 1 unit 42S
161 45 90 -- 143 40 50 100 -- 3RW5227-@@C@4 1 1 unit 42S

Type of electrical connection for the control circuit


Screw terminals 1
Spring-loaded terminals 3
Product function
Analog output A
Thermistor motor protection T
Control supply voltage
24 V AC/DC 0
110 ... 250 V AC 1
Note:
For the constraints for the motor outputs specified here,
see page 6/8.
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 480 V
196 55 110 -- 175 50 60 125 -- 3RW5234-@@C@4 1 1 unit 42S
248 75 132 -- 222 75 75 150 -- 3RW5235-@@C@4 1 1 unit 42S
296 90 160 -- 265 75 100 200 -- 3RW5236-@@C@4 1 1 unit 42S
364 110 200 -- 322 100 125 250 -- 3RW5243-@@C@4 1 1 unit 42S
433 132 250 -- 381 125 150 300 -- 3RW5244-@@C@4 1 1 unit 42S
546 160 315 -- 483 150 200 400 -- 3RW5245-@@C@4 1 1 unit 42S
641 200 355 -- 568 200 200 450 -- 3RW5246-@@C@4 1 1 unit 42S
814 250 400 -- 721 250 250 600 -- 3RW5247-@@C@4 1 1 unit 42S
987 315 560 -- 873 300 350 750 -- 3RW5248-@@C@4 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6
Product function
Analog output A
Thermistor motor protection T
Control supply voltage
24 V AC/DC 0
110 ... 250 V AC 1
Note:
For the constraints for the motor outputs specified here,
see page 6/8.
* You can order this quantity or a multiple thereof.
Illustrations are approximate Siemens IC 10 · 2023 6/69
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > Inside-delta circuit IE3 ready IE4 ready IE3/IE4 ready

For normal starting (CLASS 10A)

3RW521. 3RW522. 3RW523. 3RW524.


At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 600 V
22.5 5.5 11 15 19.9 5 5 10 15 3RW5213-@@C@5 1 1 unit 42S
31.5 7.5 15 18.5 28 7.5 7.5 20 25 3RW5214-@@C@5 1 1 unit 42S
43.3 11 18.5 22 39 10 10 25 30 3RW5215-@@C@5 1 1 unit 42S
6

55.4 15 22 30 49 15 15 30 40 3RW5216-@@C@5 1 1 unit 42S


65.8 18.5 30 37 58 15 20 40 50 3RW5217-@@C@5 1 1 unit 42S
81.4 22 45 45 72 20 25 50 60 3RW5224-@@C@5 1 1 unit 42S
109 30 55 55 96 30 30 75 75 3RW5225-@@C@5 1 1 unit 42S
133 37 75 90 118 30 40 75 100 3RW5226-@@C@5 1 1 unit 42S
161 45 90 110 143 40 50 100 125 3RW5227-@@C@5 1 1 unit 42S

Type of electrical connection for the control circuit


Screw terminals 1
Spring-loaded terminals 3
Product function
Analog output A
Thermistor motor protection T
Control supply voltage
24 V AC/DC 0
110 ... 250 V AC 1
Note:
For the constraints for the motor outputs specified here,
see page 6/8.
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current at at at current at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 600 V
196 55 110 132 175 50 60 125 150 3RW5234-@@C@5 1 1 unit 42S
248 75 132 160 222 75 75 150 200 3RW5235-@@C@5 1 1 unit 42S
296 90 160 200 265 75 100 200 250 3RW5236-@@C@5 1 1 unit 42S
364 110 200 250 322 100 125 250 300 3RW5243-@@C@5 1 1 unit 42S
433 132 250 315 381 125 150 300 350 3RW5244-@@C@5 1 1 unit 42S
546 160 315 355 483 150 200 400 500 3RW5245-@@C@5 1 1 unit 42S
641 200 355 450 568 200 200 450 600 3RW5246-@@C@5 1 1 unit 42S
814 250 400 500 721 250 250 600 800 3RW5247-@@C@5 1 1 unit 42S
987 315 560 630 873 300 350 750 950 3RW5248-@@C@5 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6
Product function
Analog output A
Thermistor motor protection T
Control supply voltage
24 V AC/DC 0
110 ... 250 V AC 1
Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


6/70 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > Accessories

■ Selection and ordering data


Product Manufacturer's Product Application Article No. Price PU PS* PG
designation article number of version per PU (UNIT,
the soft starter SET, M)

Fan covers
Fan cover 3RW5216/17 (1x), -- -- 3RW5983-0FC00 1 1 unit 42S
3RW5226/27 (2x),
3RW523 (2x)
3RW524 (1x) -- -- 3RW5984-0FC00 1 1 unit 42S
3RW5983-0FC00
Terminal covers
Terminal 3RW522 (2x), -- -- 3RW5983-0TC20 1 1 unit 42S
cover 3RW523 (2x)

3RW5983-0TC20
3RW524 (2x) -- -- 3RW5984-0TC20 1 1 unit 42S

6
3RW5984-0TC20
Enclosure components
Hinged 3RW52 With cutout -- 3RW5950-0GL30 1 1 unit 42S
cover for High-
Feature
HMI module

3RW5950-0GL30
With cutout -- 3RW5950-0GL40 1 1 unit 42S
for Standard
HMI module

3RW5950-0GL40
Communications modules
Communica- 3RW52 PROFINET -- 3RW5980-0CS00 1 1 unit 42S
tions Standard
module1) PROFIBUS -- 3RW5980-0CP00 1 1 unit 42S
EtherNet/IP -- 3RW5980-0CE00 1 1 unit 42S

3RW5980-0CS00
Modbus RTU -- 3RW5980-0CR00 1 1 unit 42S
Modbus TCP -- 3RW5980-0CT00 1 1 unit 42S

3RW5980-0CR00
1)
Use the recommended connection plugs for attaching the bus connecting
cable (e.g. angled or suitable for industrial use), see Equipment Manual for
the relevant communications module.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/71
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
General Performance soft starters
3RW52 soft starters > Accessories

Product Manufacturer's Product Application Article No. Price PU PS* PG


designation article number of version per PU (UNIT,
the soft starter SET, M)

HMI modules
HMI module 3RW52 High-Feature -- 3RW5980-0HF00 1 1 unit 42S

3RW5980-0HF00
Standard -- 3RW5980-0HS00 1 1 unit 42S

3RW5980-0HS00
IP65 door 3RW52 IP65 For 3RW5980-0HD00 1 1 unit 42S
mounting kit HMI modules
for HMI
modules
6

3RW5980-0HD00
Connecting cables
HMI 3RW52 5 m, round For door 3RW5980-0HC60 1 1 unit 42S
connecting 2.5 m, round mounting 3UF7933-0BA00-0 1 1 unit 42J
cable
3UF793.-0BA00-0 1.0 m, round 3UF7937-0BA00-0 1 1 unit 42J
0.5 m, round 3UF7932-0BA00-0 1 1 unit 42J
0.1 m, flat For mounting 3UF7931-0AA00-0 1 1 unit 42J
in the device

3UF7931-0AA00-0
Further accessories
Push-in lugs -- Two lugs are For 3ZY1311-0AA00 1 10 units 41L
for wall required per HMI modules
mounting device and commu-
nications
modules
3ZY1311-0AA00
Blank labels
Unit labeling -- 20 mm x For 3RT2900-1SB20 100 340 41B
plates1) 7 mm, SIRIUS units
titanium gray devices
IC01_00181

3RT2900-1SB20
1) PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


6/72 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW50 soft starters > General data

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter Simulation Tool for Soft Starters (STS), see page 6/9 or
Industry Mall, see www.siemens.com/product?3RW50 https://support.industry.siemens.com/cs/ww/en/view/101494917
TIA Selection Tool Cloud (TST Cloud), see SIRIUS Soft Starter ES (TIA Portal) for diagnostics, see page 6/9 or
www.siemens.com/tstcloud/?node=3rw50 https://support.industry.siemens.com/cs/ww/en/ps/24230/dl
Industry Online Support (SIOS) topic page, see Decision-making support for motor starting – Starting and running three-phase
https://support.industry.siemens.com/cs/ww/en/view/109747404 asynchronous motors efficiently, see www.siemens.com/motorstart-guide
Conversion tool, see www.siemens.com/conversion-tool

SIRIUS 3RW50 Basic Performance soft starters are the compact


solution for standard applications. With 2-phase motor control,
they cover the performance range from 75 to 315 kW (at 400 V).
Optional HMI modules for installation in the control cabinet door,
laterally mountable communications modules (PROFINET,
PROFIBUS, EtherNet/IP and Modbus) and either an analog
output or thermistor motor protection ensure maximum flexibility.
With their modern hybrid switching technology,
the SIRIUS 3RW50 soft starters offer efficient switching
for long-term, energy-saving use.

6
SIRIUS 3RW50 soft starters device family

6 1 3RW50 soft starter


5
2 HMI modules
3 Communications modules
4
4 Box terminal blocks
5 Terminal covers for box terminals
6 Terminal covers for cable lugs
and busbar connections
1
7 Fan cover
8 Push-in lugs for wall mounting
8 9 IP65 door mounting kit
10 HMI soft starter connecting cable
11 COM connecting cable
3
IC01_00571a

7 8
11

2
9
4

5 6

10

SIRIUS 3RW50 Basic Performance soft starter with accessories (see page 6/82), for expansion with HMI module or communications module

Siemens IC 10 · 2023 6/73


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW50 soft starters > General data

■ Benefits
6

Product characteristics/function Performance features/benefits

Hybrid switching technology and 2-phase motor control Minimum power loss and optimized motor control by avoiding DC components

Small and compact design Space-saving, clearly arranged control panel layout

TIA integration – communications modules and HMI modules optional Efficient configuration and maximum flexibility in automation engineering

Motor overload and intrinsic device protection without additional wiring Adjustable trip classes, integrated diagnostics functions

Soft Torque Reduced mechanical loading and optimum pump stop

Parameterization using potentiometers Simple and fast commissioning

Wide range for control supply and main voltage Low variance, high system availability even with weak supply networks

Certified according to ATEX/IECEx directive Suitable for the starting of explosion-proof motors with "increased safety" type
of protection

6/74 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW50 soft starters > General data

■ Technical specifications
More information
Technical specifications, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/25252/faq
https://support.industry.siemens.com/cs/ww/en/ps/25252/td Simulation Tool for Soft Starters (STS), see page 6/9 or
Equipment Manual, see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/109753750

Type 3RW5055 3RW5072


3RW5056 3RW5073
3RW5074
3RW5075
3RW5076
3RW5077
Installation/fixing/dimensions
Width x height x depth mm 120 x 198 x 249 160 x 230 x 282
H

Type of mounting Screw fixing


Mounting position For vertical mounting surface can be rotated +/- 90°,
for vertical mounting surface can be tilted +/- 22.5° forward or backward

6
Distance to be maintained with side-by-side mounting
• Above mm 100
• At the side mm 5
• Below mm 75
Installation altitude at height above sea level, maximum1) m 5 000
Degree of protection IP on the front according to IEC 60529 IP00 (IP20 with cover)
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching from the front with cover
Ambient conditions
Ambient temperature
• During operation2) °C -25 ... +60
• During storage and transport °C -40 ... +80
Environmental category according to IEC 60721
• During operation 3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist),
3S2 (sand must not get into the devices), 3M6
• During storage 1K6 (only occasional condensation), 1C2 (no salt mist),
1S2 (sand must not get into the devices), 1M4
• During transport 2K2, 2C1, 2S1, 2M2 (max. height of fall 0.3 m)
1) Derating from 1 000 m, see characteristic curve on page 6/8. 2) Note derating above 40 °C.

Type 3RW50..-..B0. 3RW50..-..B1.


Control circuit/control
Control supply voltage
• At AC/DC V 24/24 --/--
• At AC V -- 110 ... 250
• Relative negative tolerance/relative positive tolerance with AC % -20/20 -15/10
• Relative negative tolerance/relative positive tolerance with DC % -20/20 --/--
Frequency of the control supply voltage Hz 50 ... 60
• Relative negative tolerance/relative positive tolerance % -10/10
Type of overvoltage protection Varistors
Type of short-circuit protection for control circuit1) Fuse 4 A gG (Icu =1 kA), fuse 6 A quick-response (Icu =1 kA),
MCB C1 (Icu = 600 A), MCB C6 (Icu = 300 A)
1)
Not included in scope of supply.

Type 3RW50..-..B.4 3RW50..-..B.5


Power electronics
Operational voltage V 200 ... 480 200 ... 600
• Relative negative tolerance/relative positive tolerance % -15/10
Operating frequency Hz 50 ... 60
• Relative negative tolerance/relative positive tolerance % -10/10
Minimum load [% of IM]1) % 15
Maximum cable length between soft starter and motor m 800
1)
Relative to the smallest adjustable Ie.

Siemens IC 10 · 2023 6/75


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW50 soft starters > General data

Type 3RW5055 3RW5056


Rated operational current Ie A 143 171
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 143/128/118 171/153/141
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43
- Start-up time 10 s 1/h 18 18
• 350% IM
- Start-up time 5 s 1/h 28 28
- Start-up time 10 s 1/h 10 9
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21
- Start-up time 20 s 1/h 8 8
6

• 350% IM
- Start-up time 10 s 1/h 12 9
- Start-up time 20 s 1/h 4 --
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 108/98/88 135/123/111
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10
- Start-up time 40 s 1/h 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7
- Start-up time 40 s 1/h 2.5 2.5
Adjustable rated motor current IM
• Minimum/maximum A 68/143 81/117

Type 10
3RW5072 3RW5073 3RW5074 3RW5075 3RW5076 3RW5077
Rated operational current Ie A 210 250 315 370 470 570
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43 43 43 28
- Start-up time 10 s 1/h 18 18 18 18 18 11
• 350% IM
- Start-up time 5 s 1/h 28 28 28 28 28 16
- Start-up time 10 s 1/h 8 10 10 10 10 4
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 10 s 1/h 21 21 21 21 20 21
- Start-up time 20 s 1/h 8 8 8 8 7 8
• 350% IM
- Start-up time 10 s 1/h 8 13 12 13 12 13
- Start-up time 20 s 1/h -- 4 4 4 2 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 162/146/130 200/180/160 219/195/171 258/230/202 272/254/218 284/262/240
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5 2.5
Adjustable rated motor current IM
• Minimum/maximum A 90/210 100/250 135/315 160/370 200/470 240/570

6/76 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW50 soft starters > General data
Motor feeders according to IEC with 3VA circuit breakers (without semiconductor protection)
Type of coordination "1", CLASS 10,
short-circuit breaking capacity Iq in kA, see table
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

Q1

Q11
NSB0_01902

M
3~

Soft starters Circuit breakers


for 400 V systems for 500 V systems
Q11 Q1 Iq Q1 Iq
Type Type kA Type kA
Type of Standard (inline) circuit

6
ToC
coordination 1
"1"
3RW5055 3VA2220-7MN32-0AA0 20 3VA2220-7MN32-0AA0 20
3RW5056 3VA2220-7MN32-0AA0 20 3VA2220-7MN32-0AA0 20
3RW5072 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5073 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5074 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5075 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5076 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5077 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65

Note:
The service factor and measurement inaccuracies, for example,
have been taken into account for the selection of the specified
motor starter protectors/circuit breakers; the specified short-
circuit breaking capacities Iq in kA are covered by combination
tests. Smaller motor starter protectors/circuit breakers from the
same series can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must match
the connected three-phase motor, the short-circuit and overload
requirements of the application, and the line protection for the
cables used.

Siemens IC 10 · 2023 6/77


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW50 soft starters > General data
Motor feeders according to IEC with 3NA3 fuses
gG class full-range fuses for cable and line protection according
to IEC 60269-2, without semiconductor protection
Type of coordination "1",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1

Q21

Q11
NSB0_01904

M
3~

Soft starters gG class fuse Line contactor (optional)


for systems for systems for systems
6

up to 600 V up to 480 V up to 600 V


Q11 F1 Q21 Q21
Type Type Type Type
Type of ToC Standard (inline) circuit
coordination 1
"1"
3RW5055 3NA3244-6 3RT1055 3RT1055
3RW5056 3NA3244-6 3RT1056 3RT1064
3RW5072 2 x 3NA3354-6 3RT1064 3RT1064
3RW5073 2 x 3NA3354-6 3RT1065 3RT1065
3RW5074 2 x 3NA3365-6 3RT1075 3RT1075
3RW5075 2 x 3NA3365-6 3RT1075 3RT1075
3RW5076 2 x 3NA3365-6 3RT1076 3RT1076
3RW5077 2 x 3NA3365-6 3TF68 3TF68

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.

6/78 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW50 soft starters > General data
Motor feeders according to IEC with 3NE1 SITOR fuses
gR/gS class full-range fuses for semiconductor protection,
cable and line protection (gS)
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F’1

Q21

Q11
NSB0_01905

M
3~

Soft starters gR/gS class fuse Line contactor (optional)


for systems for systems for systems

6
up to 600 V up to 480 V up to 600 V
Q11 F’1 Q21 Q21
Type Type Type Type
Type of ToC Standard (inline) circuit
coordination 2
"2"
3RW5055 3NE1227-0 3RT1055 3RT1055
3RW5056 3NE1230-0 3RT1056 3RT1064
3RW5072 3NE1230-2 3RT1064 3RT1064
3RW5073 3NE1331-0 3RT1065 3RT1065
3RW5074 3NE1333-2 3RT1075 3RT1075
3RW5075 3NE1334-2 3RT1075 3RT1075
3RW5076 3NE1436-2 3RT1076 3RT1076
3RW5077 3NE1437-2 3TF68 3TF68

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.

Siemens IC 10 · 2023 6/79


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW50 soft starters > General data
Motor feeders according to IEC with 3NE3 fuses
aR class partial-range fuses for semiconductor protection
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1

Q21

F3

Q11
NSB0_01906

M
3~

Soft starters gG class fuse aR class fuse Line contactor (optional)


for systems for systems for systems for systems
6

up to 600 V up to 600 V up to 480 V up to 600 V


Q11 F1 F3 Q21 Q21
Type Type Type Type Type
Type of ToC Standard (inline) circuit
coordination 2
"2"
3RW5055 3NA3244-6 3NE3334-0B 3RT1055 3RT1055
3RW5056 3NA3244-6 3NE3335 3RT1056 3RT1064
3RW5072 2 x 3NA3354-6 3NE3333 3RT1064 3RT1064
3RW5073 2 x 3NA3354-6 3NE3335 3RT1065 3RT1065
3RW5074 2 x 3NA3365-6 3NE3335 3RT1075 3RT1075
3RW5075 2 x 3NA3365-6 3NE3336 3RT1075 3RT1075
3RW5076 2 x 3NA3365-6 3NE3340-8 3RT1076 3RT1076
3RW5077 2 x 3NA3365-6 3NE3340-8 3TF68 3TF68

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.
For CLASS 10 applications, as an alternative to the gG class full-
range fuses for cable and line protection 3NA3 (F1), 3VA circuit
breakers can also be used, possibly with reduced short-circuit
breaking capacity (see page 6/77). In these cases, optional line
contactors can be dispensed with.

6/80 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
IE3 ready IE4 ready IE3/IE4 ready 3RW50 soft starters > Standard (inline) circuit

■ Selection and ordering data


For normal starting (CLASS 10E)

3RW5055 3RW5075
At 40 °C At 50 °C Size Article No. Price PU PS* PG
Opera- Operating power Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional for three-phase tional SET, M)
current motors current
at at at at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 480 V
143 37 75 -- 128 40 40 100 -- S6 3RW5055-@@B@4 1 1 unit 42S
171 45 -- 153 50 50 -- S6 1 1 unit 42S

6
90 100 3RW5056-@@B@4
210 55 110 -- 186 60 60 150 -- S12 3RW5072-@@B@4 1 1 unit 42S
250 75 132 -- 220 60 75 150 -- S12 3RW5073-@@B@4 1 1 unit 42S
315 90 160 -- 279 75 100 200 -- S12 3RW5074-@@B@4 1 1 unit 42S
370 110 200 -- 328 100 125 250 -- S12 3RW5075-@@B@4 1 1 unit 42S
470 132 250 -- 416 150 150 350 -- S12 3RW5076-@@B@4 1 1 unit 42S
570 160 315 -- 504 150 200 400 -- S12 3RW5077-@@B@4 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6
Product function
Analog output A
Thermistor motor protection T
Control supply voltage
24 V AC/DC 0
110 ... 250 V AC 1
Note:
For the constraints for the motor outputs specified here,
see page 6/8.
At 40 °C At 50 °C Size Article No. Price PU PS* PG
Opera- Operating power Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional for three-phase tional SET, M)
current motors current
at at at at at at at
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp
Operational voltage 200 ... 600 V
143 37 75 90 128 40 40 100 125 S6 3RW5055-@@B@5 1 1 unit 42S
171 45 90 110 153 50 50 100 150 S6 3RW5056-@@B@5 1 1 unit 42S
210 55 110 132 186 60 60 150 150 S12 3RW5072-@@B@5 1 1 unit 42S
250 75 132 160 220 60 75 150 200 S12 3RW5073-@@B@5 1 1 unit 42S
315 90 160 200 279 75 100 200 250 S12 3RW5074-@@B@5 1 1 unit 42S
370 110 200 250 328 100 125 250 300 S12 3RW5075-@@B@5 1 1 unit 42S
470 132 250 315 416 150 150 350 450 S12 3RW5076-@@B@5 1 1 unit 42S
570 160 315 355 504 150 200 400 500 S12 3RW5077-@@B@5 1 1 unit 42S

Type of electrical connection for the control circuit


Spring-loaded terminals 2
Screw terminals 6
Product function
Analog output A
Thermistor motor protection T
Control supply voltage
24 V AC/DC 0
110 ... 250 V AC 1
Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/81
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW50 soft starters > Accessories

■ Selection and ordering data


Product Manufacturer's Product Application Article No. Price PU PS* PG
designation article number version per PU (UNIT,
of the soft starter SET, M)

Fan covers
Fan cover 3RW50 (1x) -- -- 3RW5985-0FC00 1 1 unit 42S

3RW5985-0FC00
Box terminal block
Box terminal 3RW505 (2x) Up to 70 mm2 -- 3RT1955-4G 1 1 unit 41B
block for round Up to 120 mm2 -- 3RT1956-4G 1 1 unit 41B
and ribbon
cables 3RW507 (2x) Up to -- 3RT1966-4G 1 1 unit 41B
240 mm2
(with auxiliary
3RT1956-4G conductor
connection)
Terminal covers
Covers for 3RW505 (2x) -- -- 3RT1956-4EA2 1 1 unit 41B
box terminals 3RW507 (2x) -- -- 3RT1966-4EA2 1 1 unit 41B
6

3RT1956-4EA2
Covers for 3RW505 (2x) -- -- 3RT1956-4EA1 1 1 unit 41B
cable lugs 3RW507 (2x) -- -- 3RT1966-4EA1 1 1 unit 41B
and busbar
connections

3RT1966-4EA1
Communications modules
Communica- 3RW50 PROFINET -- 3RW5980-0CS00 1 1 unit 42S
tions module1) Standard
PROFIBUS 3RW5980-0CP00 1 1 unit 42S
EtherNet/IP 3RW5980-0CE00 1 1 unit 42S
Modbus RTU 3RW5980-0CR00 1 1 unit 42S
Modbus TCP 3RW5980-0CT00 1 1 unit 42S

3RW5980-0CS00
COM 3RW50 0.3 m, round -- 3RW5900-0CC00 1 1 unit 42S
connecting
cable
3RW5900-0CC00 For mounting
laterally on the
device
1)
Use the recommended connection plugs for attaching the bus connecting
cable (e.g. angled or suitable for industrial use), see Equipment Manual for
the relevant communications module.

* You can order this quantity or a multiple thereof.


6/82 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW50 soft starters > Accessories

Product Manufacturer's Product Application Article No. Price PU PS* PG


designation article number version per PU (UNIT,
of the soft starter SET, M)

HMI modules
HMI module 3RW50 High-Feature -- 3RW5980-0HF00 1 1 unit 42S

3RW5980-0HF00
Standard -- 3RW5980-0HS00 1 1 unit 42S

3RW5980-0HS00
IP65 door 3RW50 IP65 For HMI 3RW5980-0HD00 1 1 unit 42S
mounting kit modules
for HMI
modules

6
3RW5980-0HD00
Connecting cables
HMI 3RW50 5 m, round For door 3RW5980-0HC60 1 1 unit 42S
connecting 2.5 m, round mounting 3UF7933-0BA00-0 1 1 unit 42J
cable
3UF793.-0BA00-0 1.0 m, round 3UF7937-0BA00-0 1 1 unit 42J
0.5 m, round 3UF7932-0BA00-0 1 1 unit 42J
Further accessories
Push-in lugs -- Two lugs are For HMI 3ZY1311-0AA00 1 10 units 41L
for wall required per modules
mounting device and com-
munica-
tions
modules
3ZY1311-0AA00
Blank labels
Unit labeling -- 20 mm x For SIRIUS 3RT2900-1SB20 100 340 41B
plates1) 7 mm, devices units
titanium gray
IC01_00181

3RT2900-1SB20
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/83
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW40 soft starters > General data

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter TIA Selection Tool Cloud (TST Cloud), see
Industry Mall, see www.siemens.com/product?3RW40 www.siemens.com/tstcloud/?node=3rw40
Simulation Tool for Soft Starters (STS), see page 6/9 or
https://support.industry.siemens.com/cs/ww/en/view/101494917
Conversion tool, see www.siemens.com/conversion-tool

The SIRIUS 3RW40 Basic Performance soft starters are suitable


for soft starting and stopping of three-phase asynchronous
motors.
Thanks to 2-phase control, not only is the current kept at
minimum values in all three phases throughout the entire starting
time, but disturbing direct current components are also
eliminated. This not only enables the 2-phase starting of motors
up to 55 kW (at 400 V) but also avoids the current and torque
peaks which occur e.g. with star-delta (wye-delta) starters.
The SIRIUS 3RW40 soft starters are suitable for starting
explosion-proof motors with "increased safety" type of protection
EEx e according to ATEX Directive 94/9/EC.
SIRIUS 3RW40 soft starter
6

2 1 3RW40 soft starter

2 Link module to motor starter protector


3 Terminal cover for box terminals (S2, S3)
6
3 4 Terminal cover for
cable lug and busbar connections (S3)
5 Auxiliary conductor terminal (S3)
5 6 Infeed terminal (S0)
4 7 Fan
8 Sealing cover

8
IC01_00539a

SIRIUS 3RW40 Basic Performance soft starter with accessories (see page 6/94)

6/84 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW40 soft starters > General data

■ Benefits

3RW402. 3RW403. 3RW404.

Product characteristics/function Performance features/benefits

Small and compact design Space-saving, clearly arranged control panel layout

Motor overload and intrinsic device protection without additional wiring Adjustable trip classes, integrated diagnostics functions

Integrated in the SIRIUS modular system Link modules to motor starter protectors

Hybrid switching technology and 2-phase motor control Minimum power loss and optimized motor control by avoiding DC components

6
Certified according to ATEX Directive 94/9/EC Suitable for starting explosion-proof motors with "increased safety" type of
protection EEx e.

Optional thermistor motor protection Full motor protection

Siemens IC 10 · 2023 6/85


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW40 soft starters > General data

■ Technical specifications
More information
Technical specifications, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/25251/faq
https://support.industry.siemens.com/cs/ww/en/ps/25251/td Simulation Tool for Soft Starters (STS), see page 6/9 or
Equipment Manual, see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/38752095

Type 3RW402. 3RW403. 3RW404.


Mechanics and environment
Mounting dimensions (W x H x D)
• Screw terminals mm 45 x 125 x 154 55 x 144 x 170 70 x 160 x 188
• Spring-loaded terminals mm 45 x 150 x 154 55 x 144 x 170 70 x 160 x 188
H

D
W

Permissible ambient temperature


During operation °C -25 ... +60 (derating from +40)
During storage °C -40 ... +80
Weight kg 0.77 1.35 1.9
Permissible mounting position1)
• With auxiliary fan

NSB0_00649a
22,5° 22,5°
(for 3RW402. to 3RW404.) 90° 90°
6

• Without auxiliary fan 10° 10°


(for 3RW402. to 3RW404.) 10° 10°

NSB0_01897
Installation type1) Stand-alone
installation  
16%B

16%B
    ุPP ุLQ      ุPP ุLQ 
   ุPP ุLQ     ุPP ุLQ 
     
 ุPP ุLQ   ุPP ุLQ 
 

Permissible installation altitude m 5 000


(Derating from 1 000, see characteristic curve on page 6/8)
Degree of protection IP on the front according to IEC 60529 IP20
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching from the front
1)
In the case of deviations, please observe derating, see Equipment Manual
in the chapter "Configuration".

Type Terminal 3RW402., 3RW403., 3RW404.


Control electronics
Rated values
Rated control supply voltage A1/A2 V 24 AC/DC 110 ... 230 AC/DC
• Tolerance %  20 -15/+10
Rated frequency Hz 50/60
• Tolerance %  10

Type 3RW402.-..B.4, 3RW402.-..B.5,


3RW403.-..B.4, 3RW403.-..B.5,
3RW404.-..B.4 3RW404.-..B.5
Power electronics
Rated operational voltage V AC 200 ... 480 400 ... 600
Tolerance % -15/+10
Maximum blocking voltage (thyristor) V AC 1 600
Rated frequency Hz 50/60
Tolerance %  10
Uninterrupted duty at 40 °C (% of Ie) % 115
Minimum load (% of smallest adjustable rated motor current IM) % 20 (at least 2 A)
Maximum cable length between soft starter and motor m 300

6/86 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW40 soft starters > General data

Type 3RW4024 3RW4026 3RW4027 3RW4028


Power electronics
Load rating with rated operational current Ie
• According to IEC and UL/CSA1), individual mounting A 12.5/11/10 25.3/23/21 32.2/29/26 38/34/31
at 40/50/60 °C, AC-53a
Smallest adjustable rated motor current IM
For the motor overload protection A 5 10 17 23
Power loss
• In operation after completed starting with uninterrupted rated W 2 8 13 19
operational current (40 °C) approx.
• During starting with current limiting set to 300% IM (40 °C) W 68 188 220 256
Permissible rated motor current and starts per hour
• For normal starting (CLASS 10) at 40/50 °C
- Rated motor current IM2), start-up time 3 s A 12.5/11 25/23 32/29 38/34
- Starts per hour3) 1/h 50/50 23/23 23/23 19/19
- Rated motor current IM2), start-up time 4 s A 12.5/11 25/23 32/29 38/34
- Starts per hour3) 1/h 36/36 15/15 16/16 12/12
• For heavy starting (CLASS 20) at 40/50 °C
- Rated motor current IM2), start-up time 6 s A 10/9 21/19 27/24 31/28
- Starts per hour3) 1/h 47/47 21/21 20/20 18/18
- Rated motor current IM2), start-up time 8 s A 10/9 21/19 27/24 31/28
- Starts per hour3) 1/h 34/34 15/15 14/14 13/13
1) 3)
Measurement at 60 °C according to UL/CSA not required. For intermittent duty S4 with ON period = 30%, Tu = 40/50 °C, stand-alone

6
2) Current limiting on soft starter set to 300% IM, Tu = 40/50 °C. installation vertical. The quoted switching frequencies do not apply for
Maximum adjustable rated motor current IM dependent on CLASS setting. automatic mode. Factors for permissible switching frequency in other
mounting position, direct mounting, side-by-side mounting, and
implementation of optional auxiliary fan, see Equipment Manual
in the chapter "Configuration".

Type 3RW4036 3RW4037 3RW4038 3RW4046 3RW4047


Power electronics
Load rating with rated operational current Ie
• According to IEC and UL/CSA1), individual mounting A 45/42/39 63/58/53 72/62.1/60 80/73/66 106/98/90
at 40/50/60 °C, AC-53a
Smallest adjustable rated motor current IM
For the motor overload protection A 23 26 35 43 46
Power loss
• In operation after completed starting with uninterrupted rated W 6 12 15 12 21
operational current (40 °C) approx.
• During starting with current limiting set to 300% IM (40 °C) W 316 444 500 576 768
Permissible rated motor current and starts per hour
• For normal starting (CLASS 10) at 40/50 °C
- Rated motor current IM2), start-up time 3 s A 45/42 63/58 72/62 80/73 106/98
- Starts per hour3) 1/h 38/38 23/23 22/22 22/22 15/15
- Rated motor current IM2), start-up time 4 s A 45/42 63/58 72/62 80/73 106/98
- Starts per hour3) 1/h 26/26 15/15 15/15 15/15 10/10
• For heavy starting (CLASS 20) at 40/50 °C
- Rated motor current IM2), start-up time 6 s A 38/34 46/42 50/46 64/58 77/70
- Starts per hour3) 1/h 30/30 31/31 34/34 23/23 23/23
2)
- Rated motor current IM , start-up time 8 s A 38/34 46/42 50/46 64/58 77/70
- Starts per hour3) 1/h 21/21 22/22 24/24 16/16 16/16
1) 3)
Measurement at 60 °C according to UL/CSA not required. For intermittent duty S4 with ON period = 30%, Tu = 40/50 °C, stand-alone
2)
Current limiting on soft starter set to 300% IM, Tu = 40/50 °C. installation vertical. The quoted switching frequencies do not apply for
Maximum adjustable rated motor current IM dependent on CLASS setting. automatic mode. Factors for permissible switching frequency in other
mounting position, direct mounting, side-by-side mounting, and
implementation of optional auxiliary fan, see Equipment Manual
in the chapter "Configuration".

Siemens IC 10 · 2023 6/87


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW40 soft starters > General data
Motor feeders according to IEC with 3RV2 motor starter protectors (without semiconductor protection)
Type of coordination "1", CLASS 10,
short-circuit breaking capacity Iq in kA, see table
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

Q1

Q11
NSB0_01902

M
3~

Soft starters Motor starter protectors


for 400 V systems for 500 V systems
Q11 Q1 Iq Q1 Iq
Type Type kA Type kA
Type of Standard (inline) circuit
6

ToC
coordination 1
"1"
3RW4024 3RV2021-4AA10 55 3RV2021-4AA10 10
3RW4026 3RV2021-4DA10 55 3RV2021-4DA10 10
3RW4027 3RV2021-4EA10 55 3RV2021-4EA10 10
3RW4028 3RV2021-4FA10 55 3RV2021-4FA10 10
3RW4036 3RV2031-4WA10 10 3RV2031-4WA10 10
3RW4037 3RV2031-4JA10 10 3RV2031-4JA10 5
3RW4038 3RV2031-4KA10 10 3RV2031-4KA10 5
3RW4046 3RV2041-4RA10 11 3RV2041-4YA10 5
3RW4047 3RV2041-4MA10 11 3RV2041-4MA10 5

Note:
The specified short-circuit breaking capacities Iq in kA
are covered by combination tests. Smaller motor starter
protectors/circuit breakers from the same series can be used at
any time as smaller ones trip more quickly in the event of a short
circuit (unchanged short-circuit breaking capacity) and thus
protect the soft starter in any case. The dimensioning of the
short-circuit components must match the connected three-
phase motor, the short-circuit and overload requirements of
the application, and the line protection for the cables used.

6/88 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW40 soft starters > General data
Motor feeders according to IEC with 3NA3 fuses
gG class full-range fuses for cable and line protection according
to IEC 60269-2, without semiconductor protection
Type of coordination "1",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1

Q21

Q11
NSB0_01904

M
3~

Soft starters gG class fuse Line contactor (optional)


for systems for systems for systems for systems

6
up to 600 V up to 400 V up to 480 V up to 600 V
Q11 F1 Q21 Q21 Q21
Type Type Type Type Type
Type of ToC Standard (inline) circuit
coordination 1
"1"
3RW4024 3NA3820-6 3RT2025 3RT2025/ 3RT2025
3RT2018
(in size S00)
3RW4026 3NA3822-6 3RT2026 3RT2027 3RT2037
3RW4027 3NA3824-6 3RT2027 3RT2028 3RT2037
3RW4028 3NA3824-6 3RT2028 3RT2035 3RT2037
3RW4036 3NA3130-6 3RT2036 3RT2036 3RT2038
3RW4037 3NA3132-6 3RT2037 3RT2037 3RT2046
3RW4038 3NA3132-6 3RT2038 3RT2038 3RT2046
3RW4046 3NA3136-6 3RT2045 3RT2045 3RT2047
3RW4047 3NA3136-6 3RT2047 3RT2047 3RT1054

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.

Siemens IC 10 · 2023 6/89


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW40 soft starters > General data
Motor feeders according to IEC with 3NE1 SITOR fuses
gR/gS class full-range fuses for semiconductor protection,
cable and line protection (gS)
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F’1

Q21

Q11
NSB0_01905

M
3~

Soft starters gR/gS class fuse Line contactor (optional)


for systems for systems for systems for systems
6

up to 600 V up to 400 V up to 480 V up to 600 V


Q11 F’1 Q21 Q21 Q21
Type Type Type Type Type
Type of ToC Standard (inline) circuit
coordination 2
"2"
3RW4024 3NE1814-0 3RT2025 3RT2025/ 3RT2025
3RT2018
(in size S00)
3RW4026 3NE1803-0 3RT2026 3RT2027 3RT2037
3RW4027 3NE1020-2 3RT2027 3RT2028 3RT2037
3RW4028 3NE1020-2 3RT2028 3RT2035 3RT2037
3RW4036 3NE1020-2 3RT2036 3RT2036 3RT2038
3RW4037 3NE1820-0 3RT2037 3RT2037 3RT2046
3RW4038 3NE1820-0 3RT2038 3RT2038 3RT2046
3RW4046 3NE1021-0 3RT2045 3RT2045 3RT2047
3RW4047 3NE1022-0 3RT2047 3RT2047 3RT1054

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.

6/90 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW40 soft starters > General data
Motor feeders according to IEC with 3NE8/3NE4/3NE3/3NC fuses
aR class partial-range fuses for semiconductor protection
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1

Q21

F3

Q11
NSB0_01906

M
3~

Soft starters gG class fuse aR class fuse Cylindrical Line contactor (optional)
fuse

6
for systems for systems for systems for systems for systems for systems for systems for systems
up to 600 V up to 600 V up to 600 V up to 600 V up to 480 V up to 400 V up to 480 V up to 600 V
Q11 F1 F3 F3 F3 F3 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type
Type of ToC Standard (inline) circuit
coordination 2
"2"
3RW4024 3NA3820-6 -- 3NE4101 3NE8015-1 3NC2240 3RT2025 3RT2025/ 3RT2025
3RT2018
(in size S00)
3RW4026 3NA3822-6 -- 3NE4102 3NE8017-1 3NC2263 3RT2026 3RT2027 3RT2037
3RW4027 3NA3824-6 -- 3NE4118 3NE8018-1 3NC2280 3RT2027 3RT2028 3RT2037
3RW4028 3NA3824-6 -- 3NE4118 3NE8020-1 3NC2280 3RT2028 3RT2035 3RT2037
3RW4036 3NA3130-6 -- 3NE4120 3NE8020-1 3NC2280 3RT2036 3RT2036 3RT2038
3RW4037 3NA3132-6 -- 3NE4121 3NE8021-1 -- 3RT2037 3RT2037 3RT2046
3RW4038 3NA3132-6 3NE3221 -- 3NE8022-1 -- 3RT2038 3RT2038 3RT2046
3RW4046 3NA3136-6 3NE3222 -- 3NE8022-1 -- 3RT2045 3RT2045 3RT2047
3RW4047 3NA3136-6 3NE3224 -- 3NE8024-1 -- 3RT2047 3RT2047 3RT1054

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.
For CLASS 10 applications, as an alternative to the gG class
full-range fuses for cable and line protection 3NA3 (F1), 3RV2
motor starter protectors can also be used, possibly with reduced
short-circuit breaking capacity (see page 6/88). In these cases,
optional line contactors can be dispensed with.

Siemens IC 10 · 2023 6/91


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW40 soft starters > Standard (inline) circuit IE3 ready IE4 ready IE3/IE4 ready

■ Selection and ordering data


For normal starting (CLASS 10)

3RW402. 3RW403. 3RW404.


3RW ambient temperature 40 °C 3RW ambient temperature 50 °C Size Article No. Price PU PS* PG
Rated values of Rated values of per PU (UNIT,
three-phase motors three-phase motors SET, M)
Opera- Rating at Opera- Rating at
tional operational voltage Ue tional operational voltage Ue
current Ie 230 V 400 V 500 V current Ie 200 V 230 V 460 V 575 V
A kW kW kW A hp hp hp hp
Rated operational voltage Ue 200 ... 480 V
12.5 3 5.5 -- 11 3 3 7.5 -- S0 3RW4024-@BB@4 1 1 unit 42G
6

25 5.5 11 -- 23 5 5 15 -- S0 3RW4026-@BB@4 1 1 unit 42G


32 7.5 15 -- 29 7.5 7.5 20 -- S0 3RW4027-@BB@4 1 1 unit 42G
38 11 18.5 -- 34 10 10 25 -- S0 3RW4028-@BB@4 1 1 unit 42G
45 11 22 -- 42 10 15 30 -- S2 3RW4036-@BB@4 1 1 unit 42G
63 18.5 30 -- 58 15 20 40 -- S2 3RW4037-@BB@4 1 1 unit 42G
72 22 37 -- 62 20 20 40 -- S2 3RW4038-@BB@4 1 1 unit 42G
80 22 45 -- 73 20 25 50 -- S3 3RW4046-@BB@4 1 1 unit 42G
106 30 55 -- 98 30 30 75 -- S3 3RW4047-@BB@4 1 1 unit 42G
Rated operational voltage Ue 400 ... 600 V
12.5 -- 5.5 7.5 11 -- -- 7.5 10 S0 3RW4024-@BB@5 1 1 unit 42G
25 -- 11 15 23 -- -- 15 20 S0 3RW4026-@BB@5 1 1 unit 42G
32 -- 15 18.5 29 -- -- 20 25 S0 3RW4027-@BB@5 1 1 unit 42G
38 -- 18.5 22 34 -- -- 25 30 S0 3RW4028-@BB@5 1 1 unit 42G
45 -- 22 30 42 -- -- 30 40 S2 3RW4036-@BB@5 1 1 unit 42G
63 -- 30 37 58 -- -- 40 50 S2 3RW4037-@BB@5 1 1 unit 42G
72 -- 37 45 62 -- -- 40 60 S2 3RW4038-@BB@5 1 1 unit 42G
80 -- 45 55 73 -- -- 50 60 S3 3RW4046-@BB@5 1 1 unit 42G
106 -- 55 75 98 -- -- 75 75 S3 3RW4047-@BB@5 1 1 unit 42G

Article number supplement for connection types


• Screw terminals 1
• Spring-loaded terminals1) 2

Control supply voltage


• 24 V AC/DC 0
• 110 … 230 V AC/DC 1
1) Main connection from size S2: screw terminals.
Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


6/92 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
IE3 ready IE4 ready IE3/IE4 ready 3RW40 soft starters > Standard (inline) circuit
For normal starting (CLASS 10)

3RW402. 3RW403. 3RW404.


3RW ambient temperature 40 °C 3RW ambient temperature 50 °C Size Article No. Price PU PS* PG
Rated values of Rated values of per PU (UNIT,
three-phase motors three-phase motors SET, M)
Opera- Rating at Opera- Rating at
tional operational voltage Ue tional operational voltage Ue
current Ie 230 V 400 V 500 V current Ie 200 V 230 V 460 V 575 V
A kW kW kW A hp hp hp hp
Rated operational voltage Ue 200 ... 480 V,
with thermistor motor protection,
rated control supply voltage Us 24 V AC/DC
12.5 3 5.5 -- 11 3 3 7.5 -- S0 3RW4024-@TB04 1 1 unit 42G

6
25 5.5 11 -- 23 5 5 15 -- S0 3RW4026-@TB04 1 1 unit 42G
32 7.5 15 -- 29 7.5 7.5 20 -- S0 3RW4027-@TB04 1 1 unit 42G
38 11 18.5 -- 34 10 10 25 -- S0 3RW4028-@TB04 1 1 unit 42G
45 11 22 -- 42 10 15 30 -- S2 3RW4036-@TB04 1 1 unit 42G
63 18.5 30 -- 58 15 20 40 -- S2 3RW4037-@TB04 1 1 unit 42G
72 22 37 -- 62 20 20 40 -- S2 3RW4038-@TB04 1 1 unit 42G
80 22 45 -- 73 20 25 50 -- S3 3RW4046-@TB04 1 1 unit 42G
106 30 55 -- 98 30 30 75 -- S3 3RW4047-@TB04 1 1 unit 42G
Rated operational voltage Ue 400 ... 600 V,
with thermistor motor protection,
rated control supply voltage Us 24 V AC/DC
12.5 -- 5.5 7.5 11 -- -- 7.5 10 S0 3RW4024-@TB05 1 1 unit 42G
25 -- 11 15 23 -- -- 15 20 S0 3RW4026-@TB05 1 1 unit 42G
32 -- 15 18.5 29 -- -- 20 25 S0 3RW4027-@TB05 1 1 unit 42G
38 -- 18.5 22 34 -- -- 25 30 S0 3RW4028-@TB05 1 1 unit 42G
45 -- 22 30 42 -- -- 30 40 S2 3RW4036-@TB05 1 1 unit 42G
63 -- 30 37 58 -- -- 40 50 S2 3RW4037-@TB05 1 1 unit 42G
72 -- 37 45 62 -- -- 40 60 S2 3RW4038-@TB05 1 1 unit 42G
80 -- 45 55 73 -- -- 50 60 S3 3RW4046-@TB05 1 1 unit 42G
106 -- 55 75 98 -- -- 75 75 S3 3RW4047-@TB05 1 1 unit 42G

Article number supplement for connection types


• Screw terminals 1
• Spring-loaded terminals1) 2
1)
Main connection from size S2: screw terminals.
Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/93
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW40 soft starters > Accessories

■ Selection and ordering data


For soft starters Conductor cross-section Tighten- Article No. Price PU PS* PG
Solid or Finely AWG ing per PU (UNIT,
stranded stranded cables, torque SET, M)
with end solid or
sleeve stranded
Type Size mm² mm² AWG Nm
3-phase infeed terminals
3RW402. S0 2.5 ... 25 2.5 ... 16 10 ... 4 3 ... 4 3RV2925-5AB 1 1 unit 41E

3RV2925-5AB

For soft starters Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)
Type Size
Auxiliary conductor terminals
Auxiliary conductor terminals, 3-pole
6

3RW404. S3 For connection of auxiliary and 3RT2946-4F 1 1 unit 41B


control cables (0.5 ... 2.5 mm2)
to the main conductor terminals

3RT2946-4F
Covers for soft starters
Terminal covers for box terminals
3RW403. S2 Additional touch protection 3RT2936-4EA2 1 1 unit 41B
3RW404. S3 to be fitted at the box terminals 3RT2946-4EA2 1 1 unit 41B
(two units required per device)

3RT2936-4EA2
Terminal covers for cable lugs and busbar connections
3RW404. S3 For complying with the voltage 3RT1946-4EA1 1 1 unit 41B
clearances and as touch protection
if box terminal is removed
(two units required per device)

3RT1946-4EA1
Sealing covers
3RW402. to S0, S2, -- 3RW4900-0PB10 1 1 unit 42G
3RW404. S3

3RW4900-0PB10

* You can order this quantity or a multiple thereof.


6/94 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW40 soft starters > Accessories

For motor For soft Version Article No. Price PU (UNIT, PS* PG
starter starters per PU SET, M)
protectors
Size Size
DIN-rail adapters
For mechanical fixing of motor
starter protector and soft
starter; for snapping onto
DIN rail or for screw fixing
S2 S2 Single-unit packaging 3RA2932-1CA00 1 1 unit 41B

3RA2932-1CA00

For soft starters Article No. Price PU (UNIT, PS* PG


per PU SET, M)
Type Size
Fans (to increase switching frequency and for device mounting
in positions different to the standard position)
3RW402. S0 3RW4928-8VB00 1 1 unit 42G
3RW403., S2, S3 3RW4947-8VB00 1 1 unit 42G

6
3RW404.

3RW49..-8VB00

For soft starters Motor starter protectors Article No. Price PU (UNIT, PS* PG
per PU SET, M)
Type Size Size
Link modules to motor starter protectors1)
• Screw terminals Screw terminals

3RW402. S0 S00/S0 3RA2921-1BA00 1 1 unit 41B


3RW4036 S2 S2 3RA2931-1AA00 1 1 unit 41B
3RW404. S3 S3 3RA1941-1AA00 1 1 unit 41B
• Spring-loaded terminals Spring-loaded terminals
3RA2921-1BA00
3RW402. S0 S0 3RA2921-2GA00 1 1 unit 41B

3RA2921-2GA00
1)
Can be used in size S0 up to maximum 32 A.
Can be used in size S2 up to maximum 65 A in combination with
3RA2932-1CA00 DIN-rail adapter (specially for soft starters).
Can be used in size S3 up to maximum 64 A and only with mounting plate.

Version Article No. Price PU (UNIT, PS* PG


per PU SET, M)

Tools for opening spring-loaded terminals in sizes S00 and S0


Screwdrivers Spring-loaded terminals
For all SIRIUS devices with spring-loaded terminals
Length approx. 200 mm, 3.0 mm x 0.5 mm, 3RA2908-1A 1 1 unit 41B
titanium gray/black, partially insulated
3RA2908-1A
Blank labels
Unit labeling plates1)
For SIRIUS devices
20 mm x 7 mm, titanium gray 3RT2900-1SB20 100 340 41B
units
IC01_00181

3RT2900-1SB20
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).
* You can order this quantity or a multiple thereof.
Illustrations are approximate Siemens IC 10 · 2023 6/95
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW30 soft starters > General data

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter TIA Selection Tool Cloud (TST Cloud), see
Industry Mall, see www.siemens.com/product?3RW30 www.siemens.com/tstcloud/?node=3rw30
Simulation Tool for Soft Starters (STS), see page 6/9 or
https://support.industry.siemens.com/cs/ww/en/view/101494917
Conversion tool, see www.siemens.com/conversion-tool

The SIRIUS 3RW30 Basic Performance soft starters are suitable


for soft starting of three-phase asynchronous motors.
Thanks to 2-phase control, not only is the current kept at
minimum values in all three phases throughout the entire starting
time, but disturbing direct current components are also
eliminated. This not only enables the 2-phase starting of motors
up to 55 kW (at 400 V) but also avoids the current and torque
peaks which occur e.g. with star-delta (wye-delta) starters.

SIRIUS 3RW30 soft starter


6

1 3RW30 soft starter


2

2 Link module to motor starter protector


3 Terminal cover for box terminals (S2, S3)
6 4 Terminal cover for
3 cable lugs and busbar connections (S3)
5 Auxiliary conductor terminal (S3)
6 Infeed terminal (S00, S0)
5
4

1
IC01_00538a

SIRIUS 3RW30 Basic Performance soft starter with accessories (see page 6/104)

6/96 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW30 soft starters > General data

■ Benefits

3RW301. 3RW302. 3RW303. 3RW304.

Product characteristics/function Performance features/benefits

Small and compact design Space-saving, clearly arranged control panel layout

Parameterization using potentiometers Simple and fast commissioning

Integrated in the SIRIUS modular system Link modules to motor starter protectors

6
Hybrid switching technology and 2-phase motor control Minimum power loss and optimized motor control by avoiding DC components

■ Technical specifications
More information
Equipment Manual, see Catalog LV 10, see www.siemens.com/lowvoltage/lv10
https://support.industry.siemens.com/cs/ww/en/view/38752095
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16213/faq

Type 3RW301. 3RW302. 3RW303. 3RW304.


Mechanics and environment
Mounting dimensions (W x H x D)
• Screw terminals mm 45 x 95 x 151 45 x 125 x 151 55 x 144 x 168 70 x 160 x 186
• Spring-loaded terminals mm 45 x 117 x 151 45 x 150 x 151 55 x 144 x 168 70 x 160 x 186
H

Permissible ambient temperature


During operation °C -25 ... +60 (derating from +40)
During storage °C -40 ... +80
Weight kg 0.58 0.69 1.20 1.71
Permissible mounting position1) 10° 10°
(auxiliary fan not possible) 10° 10°
NSB0_01897

Installation type1) Stand-alone


installation  
16%B

16%B

    ุPP ุLQ      ุPP ุLQ 
   ุPP ุLQ     ุPP ุLQ 
     
 ุPP ุLQ   ุPP ุLQ 
 

Permissible installation altitude m 5 000


(Derating from 1 000, see characteristic curve on page 6/9)
Degree of protection IP on the front according to IEC 60529 IP20
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching from the front
1)
In the case of deviations, please observe derating, see Equipment Manual
in the chapter "Configuration".

Siemens IC 10 · 2023 6/97


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW30 soft starters > General data

Type Terminal 3RW301., 3RW302. 3RW303., 3RW304.


Control electronics
Rated values
Rated control supply voltage A1/A2 V 24 110 ... 230 24 110 ... 230
• Tolerance %  20 -15/+10  20 -15/+10
Rated frequency Hz 50/60
• Tolerance %  10

Type 3RW301. 3RW302. 3RW303. 3RW304.


Power electronics
Rated operational voltage V AC 200 ... 480
Tolerance % -15/+10
Rated frequency Hz 50/60
Tolerance %  10
Uninterrupted duty at 40 °C (% of Ie) % 115
Minimum load (% of Ie) % 10 (at least 1 A)
Maximum cable length between soft starter and motor m 300

Type 3RW3013 3RW3014 3RW3016 3RW3017 3RW3018


Power electronics
Load rating with rated operational current Ie
• According to IEC and UL/CSA1), individual mounting at 40/50/60 °C, AC-53a A 3.6/3.3/3 6.5/6/5.5 9/8/7 12.5/12/11 17.6/17/14
6

Power loss
• In operation after completed starting with uninterrupted rated W 0.25 0.5 1 2 4
operational current (40 °C) approx.
• During starting with 300% IM (40 °C) W 24 52 80 80 116
Permissible rated motor current and starts per hour
• For normal starting (CLASS 10) at 40/50 °C
- Rated motor current IM2), start-up time 3 s A 3.6/3.3 6.5/6.0 9/8 12.5/12.0 17.6/17.0
- Starts per hour3) 1/h 200/150 87/60 50/50 85/70 62/46
2)
- Rated motor current IM , start-up time 4 s A 3.6/3.3 6.5/6.0 9/8 12.5/12.0 17.6/17.0
- Starts per hour3) 1/h 150/100 64/46 35/35 62/47 45/32
1) 3)
Measurement at 60 °C according to UL/CSA not required. For intermittent duty S4 with ON period = 30%, Tu = 40/50 °C, stand-alone
2)
At 300% IM, Tu = 40/50 °C. installation vertical. The quoted switching frequencies do not apply for
automatic mode.

Type 3RW3026 3RW3027 3RW3028


Power electronics
Load rating with rated operational current Ie
• According to IEC and UL/CSA1), individual mounting at 40/50/60 °C, AC-53a A 25.3/23/21 32.2/29/26 38/34/31
Power loss
• In operation after completed starting with uninterrupted rated W 8 13 19
operational current (40 °C) approx.
• During starting with 300% IM (40 °C) W 188 220 256
Permissible rated motor current and starts per hour
• For normal starting (CLASS 10) at 40/50 °C
- Rated motor current IM2), start-up time 3 s A 25/23 32/29 38/34
- Starts per hour3) 1/h 23/23 23/23 19/19
- Rated motor current IM 2), start-up time 4 s A 25/23 32/29 38/34
- Starts per hour3) 1/h 15/15 16/16 12/12
1) 3)
Measurement at 60 °C according to UL/CSA not required. For intermittent duty S4 with ON period = 30%, Tu = 40/50 °C, stand-alone
2) At 300% IM, Tu = 40/50 °C. installation vertical. The quoted switching frequencies do not apply for
automatic mode. Factors for permissible switching frequency with
deviating mounting position, direct mounting, side-by-side mounting,
see Equipment Manual in the chapter "Configuration".

Type 3RW3036 3RW3037 3RW3038 3RW3046 3RW3047


Power electronics
Load rating with rated operational current Ie
• According to IEC and UL/CSA1), individual mounting at 40/50/60 °C, AC-53a A 45/42/39 65/58/53 72/62.1/60 80/73/66 106/98/90
Power loss
• In operation after completed starting with uninterrupted rated W 6 12 15 12 21
operational current (40 °C) approx.
• During starting with 300% IM (40 °C) W 316 444 500 576 768
Permissible rated motor current and starts per hour
• For normal starting (CLASS 10) at 40/50 °C
- Rated motor current IM2), start-up time 3 s A 45/42 63/58 72/62 80/73 106/108
- Starts per hour3) 1/h 38/38 23/23 22/22 22/22 15/15
- Rated motor current IM2), start-up time 4 s A 45/42 63/58 72/62 80/73 106/98
- Starts per hour3) 1/h 26/26 15/15 15/15 15/15 10/10
1) 3)
Measurement at 60 °C according to UL/CSA not required. For intermittent duty S4 with ON period = 30%, Tu = 40/50 °C, stand-alone
2) At 300% IM, Tu = 40/50 °C. installation vertical. The quoted switching frequencies do not apply for
automatic mode.

6/98 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW30 soft starters > General data
Motor feeders according to IEC with 3RV2 motor starter protectors (without semiconductor protection)
Type of coordination "1", CLASS 10,
short-circuit breaking capacity Iq in kA, see table
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

Q1

Q11
NSB0_01902

M
3~

Soft starters Motor starter protectors


for 400 V systems
Q11 Q1 Iq
Type Type kA
Type of Standard (inline) circuit

6
ToC
coordination 1
"1"
3RW3013 3RV2011-1FA10 5
3RW3014 3RV2011-1HA10 5
3RW3016 3RV2011-1JA10 5
3RW3017 3RV2011-1KA10 5
3RW3018 3RV2021-4BA10 5
3RW3026 3RV2021-4DA10 55
3RW3027 3RV2021-4EA10 55
3RW3028 3RV2021-4FA10 55
3RW3036 3RV2031-4WA10 10
3RW3037 3RV2031-4JA10 10
3RW3038 3RV2031-4KA10 10
3RW3046 3RV2041-4RA10 11
3RW3047 3RV2041-4MA10 11

Note:
The specified short-circuit breaking capacities Iq in kA
are covered by combination tests. Smaller motor starter
protectors/circuit breakers from the same series can be used at
any time as smaller ones trip more quickly in the event of a short
circuit (unchanged short-circuit breaking capacity) and thus
protect the soft starter in any case. The dimensioning of the
short-circuit components must match the connected three-
phase motor, the short-circuit and overload requirements of
the application, and the line protection for the cables used.

Siemens IC 10 · 2023 6/99


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW30 soft starters > General data
Motor feeders according to IEC with 3NA3 fuses
gG class full-range fuses for cable and line protection according
to IEC 60269-2, without semiconductor protection
Type of coordination "1",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1

Q21

Q11
NSB0_01904

M
3~

Soft starters gG class fuse Line contactor (optional)


for systems for systems for systems
6

up to 480 V up to 400 V up to 480 V


Q11 F1 Q21 Q21
Type Type Type Type
Type of ToC Standard (inline) circuit
coordination 1
"1"
3RW3013 3NA3803-6 3RT2015 3RT2015
3RW3014 3NA3805-6 3RT2015 3RT2016
3RW3016 3NA3807-6 3RT2016 3RT2017
3RW3017 3NA3810-6 3RT2018 3RT2025
3RW3018 3NA3814-6 3RT2026 3RT2026
3RW3026 3NA3822-6 3RT2026 3RT2027
3RW3027 3NA3824-6 3RT2027 3RT2028
3RW3028 3NA3824-6 3RT2028 3RT2035
3RW3036 3NA3130-6 3RT2036 3RT2036
3RW3037 3NA3132-6 3RT2037 3RT2037
3RW3038 3NA3132-6 3RT2038 3RT2038
3RW3046 3NA3136-6 3RT2045 3RT2045
3RW3047 3NA3136-6 3RT2047 3RT2047

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.

6/100 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW30 soft starters > General data
Motor feeders according to IEC with 3NE1 SITOR fuses
gR/gS class full-range fuses for semiconductor protection,
cable and line protection (gS)
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F’1

Q21

Q11
NSB0_01905

M
3~

Soft starters gR/gS class fuse Line contactor (optional)


for systems for systems for systems

6
up to 480 V up to 400 V up to 480 V
Q11 F’1 Q21 Q21
Type Type Type Type
Type of ToC Standard (inline) circuit
coordination 2
"2"
3RW3013 3NE1813-0 3RT2015 3RT2015
3RW3014 3NE1813-0 3RT2015 3RT2016
3RW3016 3NE1813-0 3RT2016 3RT2017
3RW3017 3NE1813-0 3RT2018 3RT2025
3RW3018 3NE1814-0 3RT2026 3RT2026
3RW3026 3NE1803-0 3RT2026 3RT2027
3RW3027 3NE1020-2 3RT2027 3RT2028
3RW3028 3NE1020-2 3RT2028 3RT2035
3RW3036 3NE1020-2 3RT2036 3RT2036
3RW3037 3NE1820-0 3RT2037 3RT2037
3RW3038 3NE1820-0 3RT2038 3RT2038
3RW3046 3NE1021-0 3RT2045 3RT2045
3RW3047 3NE1022-0 3RT2047 3RT2047

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.

Siemens IC 10 · 2023 6/101


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW30 soft starters > General data
Motor feeders according to IEC with 3NE8/3NE4/3NE3/3NC fuses
aR class partial-range fuses for semiconductor protection
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations for constructing motor feeders
with soft starters, see page 6/12.

F1

Q21

F3

Q11
NSB0_01906

M
3~

Soft starters gG class fuse aR class fuse Cylindrical fuse Line contactor (optional)
for systems for systems for systems for systems for systems for systems for systems
6

up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V up to 400 V up to 480 V


Q11 F1 F3 F3 F3 F3 Q21 Q21
Type Type Type Type Type Type Type Type
Type of ToC Standard (inline) circuit
coordination 2
"2"
3RW3013 3NA3803-6 -- 3NE4101 3NE8015-1 3NC2220 3RT2015 3RT2015
3RW3014 3NA3805-6 -- 3NE4101 3NE8015-1 3NC2220 3RT2015 3RT2016
3RW3016 3NA3807-6 -- 3NE4101 3NE8015-1 3NC2220 3RT2016 3RT2017
3RW3017 3NA3810-6 -- 3NE4101 3NE8015-1 3NC2250 3RT2018 3RT2025
3RW3018 3NA3814-6 -- 3NE4101 3NE8003-1 3NC2263 3RT2026 3RT2026
3RW3026 3NA3822-6 -- 3NE4102 3NE8017-1 3NC2263 3RT2026 3RT2027
3RW3027 3NA3824-6 -- 3NE4118 3NE8018-1 3NC2280 3RT2027 3RT2028
3RW3028 3NA3824-6 -- 3NE4118 3NE8020-1 3NC2280 3RT2028 3RT2035
3RW3036 3NA3130-6 -- 3NE4120 3NE8020-1 3NC2280 3RT2036 3RT2036
3RW3037 3NA3132-6 -- 3NE4121 3NE8021-1 -- 3RT2037 3RT2037
3RW3038 3NA3132-6 3NE3221 -- 3NE8022-1 -- 3RT2038 3RT2038
3RW3046 3NA3136-6 3NE3222 -- 3NE8022-1 -- 3RT2045 3RT2045
3RW3047 3NA3136-6 3NE3224 -- 3NE8024-1 -- 3RT2047 3RT2047

Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those
specified can be used at any time as smaller ones trip more
quickly in the event of a short circuit (unchanged short-circuit
breaking capacity) and thus protect the soft starter in any case.
The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor
and the line protection for the cables used.
For CLASS 10 applications, as an alternative to the gG class
full-range fuses for cable and line protection 3NA3 (F1), 3RV2
motor starter protectors can also be used, possibly with reduced
short-circuit breaking capacity (see page 6/99). In these cases,
optional line contactors can be dispensed with.

6/102 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
IE3 ready IE4 ready IE3/IE4 ready 3RW30 soft starters > Standard (inline) circuit

■ Selection and ordering data


For simple starting conditions

3RW301. 3RW302. 3RW303. 3RW304.


3RW ambient temperature 40 °C 3RW ambient temperature 50 °C Size Article No. Price PU PS* PG
Rated values of Rated values of per PU (UNIT,
three-phase motors three-phase motors SET, M)
Opera- Rating at Opera- Rating at
tional operational voltage Ue tional operational voltage Ue
current Ie 230 V 400 V 500 V current Ie 200 V 230 V 460 V 575 V
A kW kW kW A hp hp hp hp
Rated operational voltage Ue 200 ... 480 V

6
3.6 0.75 1.5 -- 3 0.5 0.5 1.5 -- S00 3RW3013-@BB@4 1 1 unit 42G
6.5 1.5 3 -- 6 1 1 3 -- S00 3RW3014-@BB@4 1 1 unit 42G
9 2.2 4 -- 8 2 2 5 -- S00 3RW3016-@BB@4 1 1 unit 42G
12.5 3 5.5 -- 12 3 3 7.5 -- S00 3RW3017-@BB@4 1 1 unit 42G
17.6 4 7.5 -- 17 3 3 10 -- S00 3RW3018-@BB@4 1 1 unit 42G
25 5.5 11 -- 23 5 5 15 -- S0 3RW3026-@BB@4 1 1 unit 42G
32 7.5 15 -- 29 7.5 7.5 20 -- S0 3RW3027-@BB@4 1 1 unit 42G
38 11 18.5 -- 34 10 10 25 -- S0 3RW3028-@BB@4 1 1 unit 42G
45 11 22 -- 42 10 15 30 -- S2 3RW3036-@BB@4 1 1 unit 42G
63 18.5 30 -- 58 15 20 40 -- S2 3RW3037-@BB@4 1 1 unit 42G
72 22 37 -- 62 20 20 40 -- S2 3RW3038-@BB@4 1 1 unit 42G
80 22 45 -- 73 20 25 50 -- S3 3RW3046-@BB@4 1 1 unit 42G
106 30 55 -- 98 30 30 75 -- S3 3RW3047-@BB@4 1 1 unit 42G

Article number supplement for connection types


• Screw terminals 1
• Spring-loaded terminals1) 2

Control supply voltage Us


• 24 V AC/DC 0
• 110 … 230 V AC/DC 1
1)
Main connection from size S2: screw terminals.
Note:
For the constraints for the motor outputs specified here,
see page 6/8.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/103
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW30 soft starters > Accessories

■ Selection and ordering data


More information
Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/38752095

Conductor cross-section Tighten- For soft Article No. Price PU PS* PG


Solid or Finely AWG cables, ing starters per PU (UNIT,
stranded stranded solid or torque SET, M)
with end stranded
sleeve
mm² mm² AWG Nm Size
3-phase infeed terminals
2.5 ... 25 2.5 ... 16 10 ... 4 3 ... 4 S00 3RV2925-5AB 1 1 unit 41E
(3RW301.),
S0
(3RW302.)

3RV2925-5AB

For soft starters Article No. Price PU PS* PG


per PU (UNIT,
SET, M)
6

Type Size
Auxiliary conductor terminals
Auxiliary conductor terminals, 3-pole
3RW304. S3 3RT2946-4F 1 1 unit 41B

3RT2946-4F
Covers for soft starters
Terminal covers for box terminals
Additional touch protection to be fitted at the box terminals
(two units required per device)
3RW303. S2 3RT2936-4EA2 1 1 unit 41B
3RW304. S3 3RT2946-4EA2 1 1 unit 41B
3RT2936-4EA2
Terminal covers for cable lugs and busbar connections
For complying with the voltage clearances and as touch
protection if box terminal is removed
(two units required per device)
3RW304. S3 3RT1946-4EA1 1 1 unit 41B

3RT1946-4EA1

For motor For Version Article No. Price PU PS* PG


starter soft per PU (UNIT,
protectors starters SET, M)
Size Size
Mounting rails for mounting contactors for the customer assembly of 3RA21
load feeders with busbar adapters for 60 mm systems
For the discrete configuration of
direct-on-line starters, an additional
mounting rail is needed for the
contactor in addition to the existing
mounting rail on the busbar adapter
for the motor starter protector.
-- S0 For pushing onto the device adapter, 8US1998-7CB45 1 10 units 14O
including fixing screws
8US1998-7CB45
DIN-rail adapters
For mechanical fixing of motor starter
protector and soft starter; for
snapping onto DIN rail or for screw
fixing
S2 S2 Single-unit packaging 3RA2932-1CA00 1 1 unit 41B

3RA2932-1CA00

* You can order this quantity or a multiple thereof.


6/104 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Basic Performance soft starters
3RW30 soft starters > Accessories

For soft starters Motor starter protectors Article No. Price PU PS* PG
per PU (UNIT,
SET, M)
Type Size Size
Link modules to motor starter protectors1)
• Screw terminals Screw terminals

3RW301. S00 S00 3RA2921-1BA00 1 1 unit 41B


3RW302. S0 S00/S0 3RA2921-1BA00 1 1 unit 41B
3RW3036 S2 S2 3RA2931-1AA00 1 1 unit 41B
3RW304. S3 S3 3RA1941-1AA00 1 1 unit 41B
3RA2921-1BA00
• Spring-loaded terminals Spring-loaded terminals

3RW301. S00 S00 3RA2911-2GA00 1 1 unit 41B


3RW302. S0 S0 3RA2921-2GA00 1 1 unit 41B

3RA2921-2GA00
1)
Can be used in size S0 up to maximum 32 A.
Can be used in size S2 up to maximum 65 A in combination with

6
3RA2932-1CA00 DIN-rail adapter (specially for soft starters).
Can be used in size S3 up to maximum 64 A and only on a mounting plate.

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Tools for opening spring-loaded terminals


in sizes S00 and S0
Screwdrivers Spring-loaded terminals
For all SIRIUS devices with spring-loaded terminals
Length approx. 200 mm, 3.0 mm x 0.5 mm, 3RA2908-1A 1 1 unit 41B
titanium gray/black, partially insulated
3RA2908-1A
Blank labels
Unit labeling plates1)
For SIRIUS devices
20 mm x 7 mm, titanium gray 3RT2900-1SB20 100 340 41B
units
IC01_00181

3RT2900-1SB20
1) PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/105
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Spare parts
For 3RW55

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter Industry Online Support (SIOS) topic page, see
Industry Mall, see www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/109747404

■ Selection and ordering data


Product Manufacturer's Product version Article No. Price PU PS* PG
designation article number per PU (UNIT,
of the soft starter SET, M)

Power semiconductor modules


Power 3RW5524-.HA.4 (3x) 480 V, 47 A 3RW5952-0SF04 1 1 unit 42S
semiconductor 3RW5525-.HA.4 (3x), 480 V, 77 A 3RW5952-0SH04 1 1 unit 42S
module 3RW5526-.HA.4 (3x)
3RW5527-.HA.4 (3x) 480 V, 93 A 3RW5952-0SJ04 1 1 unit 42S
3RW5534-.HA.4 (3x), 480 V, 143 A 3RW5953-0SL04 1 1 unit 42S
3RW5535-.HA.4 (3x)
3RW5536-.HA.4 (3x) 480 V, 171 A 3RW5953-0SM04 1 1 unit 42S
3RW5543-.HA.4 (3x) 480 V, 210 A 3RW5954-0SN04 1 1 unit 42S
6

3RW5544-.HA.4 (3x) 480 V, 250 A 3RW5954-0SP04 1 1 unit 42S


3RW5952-0SF04
3RW5545-.HA.4 (3x), 480 V, 370 A 3RW5954-0SR04 1 1 unit 42S
3RW5546-.HA.4 (3x)
3RW5547-.HA.4 (3x), 480 V, 570 A 3RW5954-0ST04 1 1 unit 42S
3RW5548-.HA.4 (3x)
3RW5552-.HA.4 (3x) 480 V, 630 A 3RW5955-0SU04 1 1 unit 42S
3RW5553-.HA.4 (3x) 480 V, 720 A 3RW5955-0SV04 1 1 unit 42S
3RW5554-.HA.4 (3x) 480 V, 840 A 3RW5955-0SW04 1 1 unit 42S
3RW5556-.HA.4 (3x) 480 V, 1 100 A 3RW5955-0SX04 1 1 unit 42S
3RW5558-.HA.4 (3x) 480 V, 1 280 A 3RW5955-0SY04 1 1 unit 42S

3RW5953-0SM06 3RW5521-.HA.6 (3x), 690 V, 47 A 3RW5952-0SF06 1 1 unit 42S


3RW5524-.HA.6 (3x)
3RW5525-.HA.6 (3x), 690 V, 77 A 3RW5952-0SH06 1 1 unit 42S
3RW5526-.HA.6 (3x)
3RW5527-.HA.6 (3x) 690 V, 93 A 3RW5952-0SJ06 1 1 unit 42S
3RW5534-.HA.6 (3x), 690 V, 143 A 3RW5953-0SL06 1 1 unit 42S
3RW5535-.HA.6 (3x)
3RW5536-.HA.6 (3x) 690 V, 171 A 3RW5953-0SM06 1 1 unit 42S
3RW5543-.HA.6 (3x) 690 V, 210 A 3RW5954-0SN06 1 1 unit 42S
3RW5544-.HA.6 (3x) 690 V, 250 A 3RW5954-0SP06 1 1 unit 42S
3RW5545-.HA.6 (3x), 690 V, 370 A 3RW5954-0SR06 1 1 unit 42S
3RW5954-0ST06 3RW5546-.HA.6 (3x)
3RW5547-.HA.6 (3x), 690 V, 570 A 3RW5954-0ST06 1 1 unit 42S
3RW5548-.HA.6 (3x)
3RW5552-.HA.6 (3x) 690 V, 630 A 3RW5955-0SU06 1 1 unit 42S
3RW5553-.HA.6 (3x) 690 V, 720 A 3RW5955-0SV06 1 1 unit 42S
3RW5554-.HA.6 (3x) 690 V, 840 A 3RW5955-0SW06 1 1 unit 42S
3RW5556-.HA.6 (3x) 690 V, 1 100 A 3RW5955-0SX06 1 1 unit 42S
3RW5558-.HA.6 (3x) 690 V, 1 280 A 3RW5955-0SY06 1 1 unit 42S
Bypass units
Bypass unit 3RW552.-.HA.., -- 3RW5953-0BY00 1 1 unit 42S
3RW553.-.HA..
3RW5543.-.HA.., 210 ... 315 A 3RW5954-0BP00 1 1 unit 42S
3RW5544.-.HA..,
3RW5545.-.HA..
3RW5953-0BY00 3RW5546.-.HA.., 370 ... 570 A 3RW5954-0BT00 1 1 unit 42S
3RW5547.-.HA..,
3RW5548.-.HA..
3RW5552, 3RW5553, 630 ... 840 A 3RW5955-0BW00 1 1 unit 42S
3RW5554
3RW5556, 3RW5558 1 100 A, 1 280 A 3RW5955-0BY00 1 1 unit 42S

* You can order this quantity or a multiple thereof.


6/106 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Spare parts
For 3RW55

Product Manufacturer's Product version Article No. Price PU PS* PG


designation article number per PU (UNIT,
of the soft starter SET, M)

Control units
Control unit 3RW551..-.HA0., 24 V 3RW5950-1UY00 1 1 unit 42S
3RW552..-.HA0.,
3RW553..-.HA0.,
3RW554..-.HA0.
3RW555..-.HA0. 3RW5955-1UY00 1 1 unit 42S
3RW551..-.HA1., 110 ... 250 V 3RW5950-1UY10 1 1 unit 42S
3RW552..-.HA1.,
3RW553..-.HA1.,
3RW554..-.HA1.
3RW5950-1UY00 3RW555..-.HA1. 3RW5955-1UY10 1 1 unit 42S
Printed circuit boards
Printed circuit 3RW5513-.HA.4 480 V, 13 A 3RW5951-0PA04 1 1 unit 42S
boards 3RW5514-.HA.4 480 V, 18 A 3RW5951-0PB04 1 1 unit 42S
3RW5515-.HA.4 480 V, 25 A 3RW5951-0PC04 1 1 unit 42S
3RW5516-.HA.4 480 V, 32 A 3RW5951-0PD04 1 1 unit 42S
3RW5517-.HA.4 480 V, 38 A 3RW5951-0PE04 1 1 unit 42S
3RW552.-.HA.4, 480 V 3RW5953-0PY04 1 1 unit 42S

6
3RW553.-.HA.4
3RW554.-.HA.4 480 V 3RW5954-0PY04 1 1 unit 42S
3RW5951-0PA04 3RW5513-.HA.5 600 V, 13 A 3RW5951-0PA05 1 1 unit 42S
3RW5514-.HA.5 600 V, 18 A 3RW5951-0PB05 1 1 unit 42S
3RW5515-.HA.5 600 V, 25 A 3RW5951-0PC05 1 1 unit 42S
3RW5516-.HA.5 600 V, 32 A 3RW5951-0PD05 1 1 unit 42S
3RW5517-.HA.5 600 V, 38 A 3RW5951-0PE05 1 1 unit 42S
3RW552.-.HA.6, 690 V 3RW5953-0PY06 1 1 unit 42S
3RW553.-.HA.6
3RW554.-.HA.6 690 V 3RW5954-0PY06 1 1 unit 42S
3RW5954-0PY06 Firing printed 3RW555.-.HA.4 480 V 3RW5955-0PY14 1 1 unit 42S
circuit boards 3RW555.-.HA.6 690 V 3RW5955-0PY16 1 1 unit 42S
TSE printed 3RW555.-.HA.4 480 V 3RW5955-0PY24 1 1 unit 42S
circuit boards 3RW555.-.HA.6 690 V 3RW5955-0PY26 1 1 unit 42S
Fans
Fan 3RW551 (1x), -- 3RW5983-0FF00 1 1 unit 42S
3RW552 (2x),
3RW553 (2x)
3RW554 (1x) -- 3RW5984-0FF00 1 1 unit 42S
3RW555 (3x) -- 3RW5985-0FF00 1 1 unit 42S
3RW5983-0FF00
Terminals and terminal covers
Box terminal 3RW552 (2x) -- 3RW5982-0TB00 1 1 unit 42S
block

3RW5982-0TB00
Removable • Screw terminals Screw terminals
control
terminals 3RW551.-1H... (2x), Contains 2 blocks 3RW5980-1TR00 1 1 unit 42S
3RW552.-1H... (2x), each with 6 terminals
3RW553.-6H... (2x),
3RW554.-6H... (2x),
3RW555.-6H... (2x)
• Spring-loaded terminals Spring-loaded terminals

3RW551.-3H... (2x), Contains 2 blocks 3RW5980-2TR00 1 1 unit 42S


3RW5980-1TR00 3RW552.-3H... (2x), each with 6 terminals
3RW553.-2H... (2x),
3RW554.-2H... (2x),
3RW555.-2H... (2x)
Terminal cover 3RW555 -- 3RW5955-0TC20 1 1 unit 42S

3RW5955-0TC20

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/107
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Spare parts
For 3RW55

Product Manufacturer's Product version Article No. Price PU PS* PG


designation article number per PU (UNIT,
of the soft starter SET, M)

Enclosure components
Lower part of 3RW552.-.HA.., -- 3RW5953-0GB00 1 1 unit 42S
enclosure 3RW553.-.HA..
3RW554.-.HA.. -- 3RW5954-0GB00 1 1 unit 42S

3RW5953-0GB00
Ventilation 3RW555 (3x) -- 3RW5955-0GC00 1 1 unit 42S
cover

3RW5955-0GC00
Cover for 3RW55..-.HA.. Titanium gray 3RW5950-0GD20 1 1 unit 42S
control cable
duct
6

3RW5950-0GD20
Front cover 3RW554.-.HA.. -- 3RW5954-0GF00 1 1 unit 42S
3RW555 -- 3RW5955-0GF00 1 1 unit 42S

3RW5954-0GF00
Hinged cover 3RW55 With cutout for 3RW5950-0GL30 1 1 unit 42S
High-Feature
HMI module

3RW5950-0GL30

* You can order this quantity or a multiple thereof.


6/108 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Spare parts
For 3RW55

Product Manufacturer's Product version Article No. Price PU PS* PG


designation article number per PU (UNIT,
of the soft starter SET, M)

HMI modules
HMI module 3RW55 High-Feature 3RW5980-0HF00 1 1 unit 42S

3RW5980-0HF00
Interface cover 3RW55 -- 3RW5980-0HL00 1 1 unit 42S

3RW5980-0HL00

6
Connecting cable for installing the HMI module in the soft starter
Connecting -- Length 0.1 m, flat 3UF7931-0AA00-0 1 1 unit 42J
cable

3UF7931-0AA00-0
Transport packaging
Transport 3RW551 -- 3RW5951-0VY00 1 1 unit 42S
packaging 3RW552, 3RW553 -- 3RW5953-0VY00 1 1 unit 42S
3RW554 -- 3RW5954-0VY00 1 1 unit 42S
3RW555 -- 3RW5955-0VY00 1 1 unit 42S

3RW5953-0VY00

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/109
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Spare parts
For 3RW55 Failsafe

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter Industry Online Support (SIOS) topic page, see
Industry Mall, see www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/109747404

■ Selection and ordering data


Product Manufacturer's Product version Article No. Price PU PS* PG
designation article number per PU (UNIT,
of the soft starter SET, M)

Fans
Fan 3RW551 (1x), -- 3RW5983-0FF00 1 1 unit 42S
3RW552 (2x),
3RW553 (2x)
3RW554 (1x) -- 3RW5984-0FF00 1 1 unit 42S

3RW5983-0FF00
Terminals and terminal covers
Box terminal 3RW552 (2x) -- 3RW5982-0TB00 1 1 unit 42S
6

block

3RW5982-0TB00
Removable • Screw terminals Screw terminals
control
terminals 3RW551.-1H... (2x), Contains 2 blocks 3RW5980-1TR00 1 1 unit 42S
3RW552.-1H... (2x), each with 6 terminals
3RW553.-6H... (2x),
3RW554.-6H... (2x)
• Spring-loaded terminals Spring-loaded terminals

3RW551.-3H... (2x), Contains 2 blocks 3RW5980-2TR00 1 1 unit 42S


3RW552.-3H... (2x), each with 6 terminals
3RW5980-1TR00 3RW553.-2H... (2x),
3RW554.-2H... (2x)
Enclosure components
Cover for 3RW55..-.HF.. Yellow 3RW5950-0GD30 1 1 unit 42S
control cable
duct

3RW5950-0GD30
Hinged cover 3RW55 With cutout for 3RW5950-0GL30 1 1 unit 42S
High-Feature
HMI module

3RW5950-0GL30

* You can order this quantity or a multiple thereof.


6/110 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Spare parts
For 3RW55 Failsafe

Product Manufacturer's Product version Article No. Price PU PS* PG


designation article number per PU (UNIT,
of the soft starter SET, M)

HMI modules
HMI module 3RW55 High-Feature 3RW5980-0HF00 1 1 unit 42S

3RW5980-0HF00
Interface cover 3RW55 -- 3RW5980-0HL00 1 1 unit 42S

3RW5980-0HL00

6
Connecting cable for installing the HMI module in the soft starter
Connecting -- Length 0.1 m, flat 3UF7931-0AA00-0 1 1 unit 42J
cable

3UF7931-0AA00-0
Transport packaging
Transport 3RW551 -- 3RW5951-0VY00 1 1 unit 42S
packaging 3RW552, 3RW553 -- 3RW5953-0VY00 1 1 unit 42S
3RW554 -- 3RW5954-0VY00 1 1 unit 42S

3RW5953-0VY00

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/111
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Spare parts
For 3RW52

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter Industry Online Support (SIOS) topic page, see
Industry Mall, see www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/109747404

■ Selection and ordering data


Product Manufacturer's Product Article No. Price PU PS* PG
designation article number version per PU (UNIT,
of the soft starter SET, M)

Power semiconductor modules


Power 3RW5224-..C.4 (3x) 480 V, 47 A 3RW5952-0SF04 1 1 unit 42S
semiconductor 3RW5225-..C.4 (3x), 480 V, 77 A 3RW5952-0SH04 1 1 unit 42S
module 3RW5226-..C.4 (3x)
3RW5227-..C.4 (3x) 480 V, 93 A 3RW5952-0SJ04 1 1 unit 42S
3RW5234-..C.4 (3x), 480 V, 143 A 3RW5953-0SL04 1 1 unit 42S
3RW5235-..C.4 (3x)
3RW5236-..C.4 (3x) 480 V, 171 A 3RW5953-0SM04 1 1 unit 42S
3RW5224-..C.5 (3x) 600 V, 47 A 3RW5952-0SF05 1 1 unit 42S
3RW5225-..C.5 (3x), 600 V, 77 A 3RW5952-0SH05 1 1 unit 42S
6

3RW5952-0SF04 3RW5226-..C.5 (3x)


3RW5227-..C.5 (3x) 600 V, 93 A 3RW5952-0SJ05 1 1 unit 42S
3RW5234-..C.5 (3x), 600 V, 143 A 3RW5953-0SL05 1 1 unit 42S
3RW5235-..C.5 (3x)
3RW5236-..C.5 (3x) 600 V, 171 A 3RW5953-0SM05 1 1 unit 42S
3RW5243 (3x) 600 V, 210 A 3RW5924-0SN05 1 1 unit 42S
3RW5244 (3x), 600 V, 315 A 3RW5924-0SQ05 1 1 unit 42S
3RW5245 (3x)
3RW5246 (3x), 600 V, 470 A 3RW5924-0SS05 1 1 unit 42S
3RW5247 (3x)
3RW5953-0SM05 3RW5248 (3x) 600 V, 570 A 3RW5924-0ST05 1 1 unit 42S

3RW5924-0ST05
Bypass units
Bypass unit 3RW522, 3RW523 -- 3RW5953-0BY00 1 1 unit 42S
3RW5243, 3RW5244, 210 ... 315 A 3RW5954-0BP00 1 1 unit 42S
3RW5245
3RW5246, 3RW5247, 370 ... 570 A 3RW5954-0BT00 1 1 unit 42S
3RW5248
3RW5953-0BY00
Control units
Control unit 3RW52..-.AC0. 24 V 3RW5920-1UA00 1 1 unit 42S
analog output
3RW52..-.AC1. 110 ... 250 V 3RW5920-1UA10 1 1 unit 42S
analog output
3RW52..-.TC0. 24 V 3RW5920-1UT00 1 1 unit 42S
thermistor
input
3RW52..-.TC1. 110 ... 250 V 3RW5920-1UT10 1 1 unit 42S
thermistor
input
3RW5920-1UA00

* You can order this quantity or a multiple thereof.


6/112 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Spare parts
For 3RW52

Product Manufacturer's Product Article No. Price PU PS* PG


designation article number version per PU (UNIT,
of the soft starter SET, M)

Printed circuit boards


Printed circuit 3RW5213-..C.4 480 V, 13 A 3RW5921-0PA04 1 1 unit 42S
board 3RW5214-..C.4 480 V, 18 A 3RW5921-0PB04 1 1 unit 42S
3RW5215-..C.4 480 V, 25 A 3RW5921-0PC04 1 1 unit 42S
3RW5216-..C.4 480 V, 32 A 3RW5921-0PD04 1 1 unit 42S
3RW5217-..C.4 480 V, 38 A 3RW5921-0PE04 1 1 unit 42S
3RW522.-..C.4, 480 V 3RW5923-0PY04 1 1 unit 42S
3RW523.-..C.4
3RW5923-0PY04 3RW524.-..C.4 480 V 3RW5924-0PY04 1 1 unit 42S
3RW5213-..C.5 600 V, 13 A 3RW5921-0PA05 1 1 unit 42S
3RW5214-..C.5 600 V, 18 A 3RW5921-0PB05 1 1 unit 42S
3RW5215-..C.5 600 V, 25 A 3RW5921-0PC05 1 1 unit 42S
3RW5216-..C.5 600 V, 32 A 3RW5921-0PD05 1 1 unit 42S
3RW5217-..C.5 600 V, 38 A 3RW5921-0PE05 1 1 unit 42S
3RW522.-..C.5, 600 V 3RW5923-0PY05 1 1 unit 42S
3RW523.-..C.5
3RW524.-..C.5 600 V 3RW5924-0PY05 1 1 unit 42S
3RW5924-0PY05

6
Fans
Fan 3RW5216/17 (1x), -- 3RW5983-0FF00 1 1 unit 42S
3RW5226/27 (2x),
3RW523 (2x)
3RW524 (1x) -- 3RW5984-0FF00 1 1 unit 42S

3RW5983-0FF00
Terminals
Box terminal block 3RW522 (2x) -- 3RW5982-0TB00 1 1 unit 42S

3RW5982-0TB00
Removable control • Screw terminals Screw terminals
terminals
3RW521.-1.C.., Contains 3RW5980-1TR00 1 1 unit 42S
3RW522.-1.C.., 2 blocks
3RW523.-6.C.., each with
3RW524.-6.C.. 6 terminals
• Spring-loaded terminals Spring-loaded terminals

3RW521.-3.C.., Contains 3RW5980-2TR00 1 1 unit 42S


3RW522.-3.C.., 2 blocks
3RW523.-2.C.., each with
3RW524.-2.C.. 6 terminals
3RW5980-1TR00
Enclosure components
Lower part of 3RW522, 3RW523 -- 3RW5953-0GB00 1 1 unit 42S
enclosure 3RW524 -- 3RW5954-0GB00 1 1 unit 42S

3RW5953-0GB00
Cover for control 3RW52 Titanium gray 3RW5950-0GD20 1 1 unit 42S
cable duct

3RW5950-0GD20

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/113
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Spare parts
For 3RW52

Product Manufacturer's Product Article No. Price PU PS* PG


designation article number version per PU (UNIT,
of the soft starter SET, M)

Enclosure components
Front cover 3RW524 -- 3RW5954-0GF00 1 1 unit 42S

3RW5954-0GF00
Hinged cover 3RW52 Without 3RW5950-0GL20 1 1 unit 42S
cutout
6

3RW5950-0GL20
Transport packaging
Transport 3RW521 -- 3RW5951-0VY00 1 1 unit 42S
packaging 3RW522, 3RW523 -- 3RW5953-0VY00 1 1 unit 42S
3RW524 -- 3RW5954-0VY00 1 1 unit 42S

3RW5953-0VY00

* You can order this quantity or a multiple thereof.


6/114 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Spare parts
For 3RW50

■ Overview
More information
Homepage, see www.siemens.com/sirius-soft-starter Industry Online Support (SIOS) topic page, see
Industry Mall, see www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/109747404

■ Selection and ordering data


Product Manufacturer's Product Article No. Price PU PS* PG
designation article number version per PU (UNIT,
of the soft starter SET, M)

Power semiconductor modules


Power 3RW505.-..B.4 (2x) 480 V, 171 A 3RW5953-0SL04 1 1 unit 42S
semiconductor 3RW505.-..B.5 (2x) 600 V, 171 A 3RW5953-0SL05 1 1 unit 42S
module

6
3RW5953-0SL0.
3RW5072 (2x) 600 V, 210 A 3RW5924-0SN05 1 1 unit 42S
3RW5073 (2x), 600 V, 315 A 3RW5924-0SQ05 1 1 unit 42S
3RW5074 (2x)
3RW5075 (2x), 600 V, 470 A 3RW5924-0SS05 1 1 unit 42S
3RW5076 (2x)
3RW5077 (2x) 600 V, 570 A 3RW5924-0ST05 1 1 unit 42S

3RW5924-0S.05
Bypass units
Bypass unit 3RW505 -- 3RW5905-0BY00 1 1 unit 42S
3RW5072, 3RW5073, 210 ... 315 A 3RW5907-0BQ00 1 1 unit 42S
3RW5074
3RW5075, 3RW5076, 370 ... 570 A 3RW5907-0BY00 1 1 unit 42S
3RW5077
3RW5905-0BY00
Control units
Control unit
Analog output 3RW505.-.AB0. 24 V 3RW5905-1UA00 1 1 unit 42S
3RW505.-.AB1. 110 ... 250 V 3RW5905-1UA10 1 1 unit 42S
3RW507.-.AB0. 24 V 3RW5907-1UA00 1 1 unit 42S
3RW507.-.AB1. 110 ... 250 V 3RW5907-1UA10 1 1 unit 42S
Thermistor input 3RW505.-.TB0. 24 V 3RW5905-1UT00 1 1 unit 42S
3RW505.-.TB1. 110 ... 250 V 3RW5905-1UT10 1 1 unit 42S
3RW507.-.TB0. 24 V 3RW5907-1UT00 1 1 unit 42S
3RW5905-1UA00 3RW507.-.TB1. 110 ... 250 V 3RW5907-1UT10 1 1 unit 42S

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/115
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RW soft starters
Spare parts
For 3RW50

Product Manufacturer's Product Article No. Price PU PS* PG


designation article number version per PU (UNIT,
of the soft starter SET, M)

Printed circuit boards


Printed circuit 3RW505.-..B.4 480 V 3RW5905-0PY04 1 1 unit 42S
board 3RW507.-..B.4 480 V 3RW5907-0PY04 1 1 unit 42S
3RW505.-..B.5 600 V 3RW5905-0PY05 1 1 unit 42S
3RW507.-..B.5 600 V 3RW5907-0PY05 1 1 unit 42S

3RW5905-0PY04
Fans
Fan 3RW505 (1x) -- 3RW5905-0FF00 1 1 unit 42S
3RW507 (1x) -- 3RW5907-0FF00 1 1 unit 42S

3RW5905-0FF00
Terminals
6

Removable control • Screw terminals Screw terminals


terminals
3RW50..-6.B.. Contains 3RW5980-1TR00 1 1 unit 42S
2 blocks
each with
6 terminals
• Spring-loaded terminals Spring-loaded terminals

3RW50..-2.B.. Contains 3RW5980-2TR00 1 1 unit 42S


2 blocks
3RW5980-1TR00 each with
6 terminals
Enclosure components
Lower part of 3RW505 -- 3RW5905-0GB00 1 1 unit 42S
enclosure 3RW507 -- 3RW5907-0GB00 1 1 unit 42S

3RW5905-0GB00
Hinged cover 3RW50 -- 3RW5900-0GL00 1 1 unit 42S

3RW5900-0GL00
Transport packaging
Transport 3RW505 -- 3RW5905-0VY00 1 1 unit 42S
packaging 3RW507 -- 3RW5907-0VY00 1 1 unit 42S

3RW5905-0VY00

* You can order this quantity or a multiple thereof.


6/116 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
General data

■ Overview
More information
Industry Mall, see www.siemens.com/product?3RF Online configurator, see www.siemens.com/sirius/configurators
Conversion tool, see www.siemens.com/conversion-tool

SIRIUS 3RF solid-state switching devices


The most reliable solution for any application
Compared to mechanical switchgear, our SIRIUS 3RF2
solid-state switching devices stand out due to their considerably
longer service life. Thanks to the high product quality,
their switching is extremely precise, reliable and, above all,
insusceptible to faults. With its variable connection methods
and a wide spread of control voltages, the SIRIUS 3RF2 family
is universally applicable. Depending on the individual
requirements of the application, our modular switchgear can
also be quite easily expanded by the addition of standardized
function modules.
Always on the sunny side with SIRIUS
Because SIRIUS 3RF2 offers even more:
• The space-saving and compact side-by-side mounting

6
ensures reliable operation up to an ambient temperature
of +60 °C.
• Thanks to fast configuration and the ease of mounting and
1-phase solid-state relay and 3-phase solid-state contactor startup, not only time but also expenses are saved.
The SIRIUS 3RF2 solid-state switching devices reliably switch Also for switching motors (see page 6/159)
a wide range of different loads with alternating voltages in
In order to achieve higher productivity, the switching frequency
50 and 60 Hz systems.
is continuously increased in drive technology. It is no problem for
SIRIUS 3RF2 solid-state switching devices for resistive/inductive our SIRIUS solid-state contactors for switching motors. With
loads: three-phase motors up to 7.5 kW, they can reliably withstand
• Solid-state relays even the highest switching frequencies. Even a continuous
change in the direction of rotation is possible with the solid-state
• Solid-state contactors reversing contactors. Both versions can be perfectly combined
• Function modules with components from the SIRIUS modular system. Connecting
with SIRIUS motor starter protectors or SIRIUS overload relays
SIRIUS 3RF2 – for almost unending activity can be implemented without any further steps.
Conventional electromechanical switchgear is often overtaxed SIRIUS 3RF3 solid-state switching devices for switching motors:
by the rise in the number of switching operations. A high
switching frequency results in frequent failure and short • Solid-state contactors
replacement cycles. However, this does not have to be the case, • Solid-state reversing contactors
because with the latest generation of our SIRIUS 3RF2 solid-
state switching devices we provide you with solid-state relays Connection methods
and contactors with a particularly long endurance – for almost The solid-state switching devices are available with screw
unending activity even under the toughest conditions and under terminals (box terminals), spring-loaded terminals or ring cable
high mechanical loading, but also in noise-sensitive areas. lug connections.
Proven time and again in service
Screw terminals
SIRIUS 3RF2 solid-state switching devices have firmly
established themselves in industrial applications. They are used
above all in applications where loads are switched frequently – Spring-loaded terminals
mainly with resistive load controllers, with the control of electrical
heat or the control of valves and motors in conveyor systems.
In addition to its use in areas with high switching frequencies, Ring cable lug connection
their silent switching means that SIRIUS is also ideally suited
for use in noise-sensitive areas, such as offices or hospitals.
The terminals are indicated in the corresponding
tables by the symbols shown on orange backgrounds.

Siemens IC 10 · 2023 6/117


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
General data
Article number scheme
Product versions Article number
Device type Solid-state relays 3RF20 @ @ – @ @ @ @ @ 1-phase, 45-mm width
3RF21 @ @ – @ @ @ @ @ 1-phase, 22.5-mm width
3RF22 @ @ – @ @ @ @ @ 3-phase, 45-mm width
Solid-state contactors 3RF23 @ @ – @ @ @ @ @ 1-phase
3RF24 @ @ – @ @ @ @ @ 3-phase
Type current e.g. 20 = 20 A @@
Connection type Screw terminals 1
Spring-loaded terminals 2
Ring cable lug connection 3
Switching function Zero-point switching A
Instantaneous switching B
Zero-point switching C Low noise
Zero-point switching D Short-circuit-proof with B MCB
1-phase or number of 1-phase A
controlled phases 2-phase B
3-phase C
Rated control supply voltage Us 24 V DC 0
24 V AC/DC 1
110 ... 230 V AC 2
110 V AC 3
4 ... 30 V DC 4
230 V AC 5
6

Rated operational voltage Ue 24 ... 230 V AC 2


48 ... 460 V AC 4
48 ... 600 V AC 5 Blocking voltage 1 200 V
48 ... 600 V AC 6 Blocking voltage 1 600 V
Example 3RF21 2 0 – 1 A A 0 6
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in
versions for better understanding of the logic behind the the selection and ordering data.
article numbers.

6/118 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
General data
Overview of the SIRIUS 3RF2 solid-state switching devices
Type Solid-state relays Solid-state contactors Function modules
1-phase 3-phase 1-phase 3-phase Converters Load monitoring Heating Power Power
22.5 mm 45 mm 45 mm Basic Extended current controllers regulators
monitoring
Usage
Simple replacement ❑ ✓ ❑ ❑ ❑ -- -- -- -- -- --
of existing
solid-state relays
Complete unit ❑ ❑ ❑ ✓ ✓ -- -- -- -- -- --
"Ready to use"
Space-saving ✓ -- ✓ ✓ ✓ ✓ ✓ -- -- -- --
1) 1)
Can be extended ✓ -- ✓ -- -- -- -- -- --
with modular
function modules
Frequent switching -- -- -- -- -- -- ✓ ✓ ✓ ✓ ✓
and monitoring of
the load and the
solid-state relay or
contactor
Monitoring of up -- -- -- -- -- -- ✓ -- ✓ ✓ --
to 6 partial loads
Monitoring of more -- -- -- -- -- -- -- ✓ -- -- --
than 6 partial loads

6
Control of the -- -- -- -- -- ✓ -- -- -- ✓ ✓
heating power
through an
analog input
Power control -- -- -- -- -- -- -- -- -- -- ✓
Startup
Easy setting of -- -- -- -- -- -- ✓ ✓ -- ✓ ✓
setpoint values with
"Teach" button
"Remote Teach" -- -- -- -- -- -- -- -- ✓ -- --
input for setting
setpoints
Mounting
Mounting on -- -- -- ✓ ✓ -- -- -- -- -- --
mounting rails or
mounting plates
Can be snapped -- -- -- -- -- ✓ ✓ ✓ ✓ ✓ ✓
directly onto
a solid-state relay
or contactor
For use with ✓ ✓ ✓ -- -- -- -- -- -- -- --
"Coolplate" heat sink
Cable routing
Connection of load ✓ -- ✓ ✓ ✓ -- ✓ ✓ ✓ ✓ ✓
circuit as for
switchgear
Connection of load -- ✓ -- -- -- -- -- -- -- -- --
circuit from above

✓ Function available
❑ Function possible
-- Function not possible
1)
The converter can also be used with 3-phase devices.

Siemens IC 10 · 2023 6/119


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
General data

■ Benefits
Main features Benefits
• LED display • Saves time and costs with fast mounting and commissioning,
• Variety of connection methods, also with high degree short startup times and easy wiring
of protection • Extremely long life, low maintenance, rugged and reliable
• Plug-in control connection • Space-saving and safe thanks to side-by-side mounting up
• Zero-point switching, 2-phase or 3-phase controlled to an ambient temperature of +60 °C
• Modular design: Standardized function modules and heat
Features sinks can be used in conjunction with solid-state relays to
• Considerable space savings thanks to a width of only 22.5 mm satisfy individual requirements.
• Variety of connection methods: Screw terminal, spring-loaded • Safety due to lifelong, vibration-resistant and shock-resistant
terminal or ring cable lug, there is no problem – they are all spring-loaded terminals even under tough conditions
finger-safe • Optimum heat transfer allows small, space-saving heat sinks
• Flexible for all applications with function modules for retrofitting to be used
• Possibility of fuseless short-circuit-proof design

■ Application
Applications The powerful SIRIUS 3RF2 solid-state relays and contactors can
be used for the simultaneous control of several heating loads.
Example: Plastics processing industry
6

By using a load monitoring module the individual partial loads


Thanks to their high switching endurance SIRIUS 3RF2 solid- can easily be monitored, and in the event of a failure a signal
state switching devices are ideal for controlling electrical heat. is generated to be sent to the controller.
This is because the more precise the temperature regulation Use in fuseless load feeders
process has to be, the higher the switching frequency.
The accurate regulation of electrical heat is used for example Compared with the fused configuration of load feeders,
in many processes in the plastics processing industry: short-circuit and line protection using miniature circuit breakers
• Band heaters heat the extrudate to the correct temperature is easy to achieve with SIRIUS 3RF2 solid-state relays and
in plastic extruders contactors.
• Heat emitters heat plastic blanks to the correct temperature A special version of the solid-state contactors can be protected
• Heat drums dry plastic granules against damage in the case of a short circuit with a miniature
circuit breaker with type B tripping characteristic. This allows the
• Heating channels keep molds at the correct temperature in low-cost and simple design of fuseless load feeders with full
order to manufacture different plastic parts without defects protection of the switchgear.

■ More information
Notes on integration in the load feeders Electromagnetic compatibility (EMC)
The SIRIUS solid-state switching devices are very easy The solid-state switching devices are suitable for interference-
to integrate into the load feeders thanks to their industrial free operation in industrial networks without further measures.
connection method and design. If they are used in public networks, it may be necessary for
conducted interference to be reduced by means of filters.
Particular attention must however be paid to the circumstances
of the installation and ambient conditions, as the performance of This does not include the solid-state contactors for resistive
the solid-state switching devices is largely dependent on these. loads of the special type 3RF23..-.CA.. "low noise". These
Depending on the version, certain restrictions must be comply with the class B limit values up to a rated current of 16 A.
observed. For detailed information, for example in relation to If other versions are used, and at currents of over 16 A, standard
solid-state contactors about the minimum spacing and to filters can be used in order to comply with the limit values.
solid-state relays about the choice of heat sink, see technical The decisive factors when it comes to selecting the filters
specifications and product data sheets, are essentially the current loading and the other parameters
https://support.industry.siemens.com/cs/ww/en/ps/16222. (operational voltage, design type, etc.) in the load feeder.
Short-circuit and overload protection Suitable filters can be ordered from EPCOS AG, see page 16/18.
Despite the rugged power semiconductors that are used, Product information and technical specifications
solid-state switching devices respond more sensitively to short
circuits in the load feeder. Consequently, special precautions For product data sheets with detailed technical specifications,
have to be taken against destruction, depending on the type dimensional drawings and characteristic curves, see
of design. https://support.industry.siemens.com/cs/ww/en/ps/16222.

Siemens generally recommends using SITOR semiconductor For more information, please enter the article number of
protection fuses. These fuses also provide protection against the required device under the tab "Product List".
destruction in the event of a short circuit even when the
solid-state contactors and solid-state relays are fully utilized.
Alternatively, if there is lower loading, protection can also
be provided by standard fuses or miniature circuit breakers.
This protection is achieved by overdimensioning the solid-state
switching devices accordingly. The technical specifications
and the product data sheets contain details both about the
solid-state fuse protection itself and about use of the devices
with conventional protection equipment.

6/120 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > General data

■ Overview
Solid-state relays (without heat sink) 3RF22 3-phase solid-state relays (without heat sink)
with a width of 45 mm
SIRIUS solid-state relays are suitable for surface mounting
on existing cooling surfaces. Mounting is quick and easy, With its compact design, which stays the same even at currents
involving just two screws. The special technology of the power of up to 55 A, the 3RF22 solid-state relay with a width of just
semiconductor ensures that there is excellent thermal contact 45 mm offers an ultra small footprint. The logical connection
with the heat sink. Depending on the nature of the heat sink, method, with the power infeed from above and load connection
the capacity reaches up to 88 A on resistive loads. from below, ensures tidy installation in the control cabinet.
The solid-state relays are available in three different versions: The 3-phase solid-state relays are available with
• 3RF21 1-phase solid-state relay with a width of 22.5 mm • 2-phase control (suitable in particular for circuits without
• 3RF20 1-phase solid-state relay with a width of 45 mm connection to the neutral conductor) and
• 3RF22 3-phase solid-state relay with a width of 45 mm • 3-phase control (suitable for star circuits with connection to
the neutral conductor or for applications in which the system
Version for resistive loads "zero-point switching" requires all phases to be switched)
This standard version is often used for 3RF20 to 3RF22 Selection notes
solid-state relays for switching heaters on and off.
When selecting solid-state relays, in addition to information
Version for inductive loads "instantaneous switching" about the network, the load and the ambient conditions, it is also
In this version, the 3RF20 and 3RF21 solid-state relays are necessary to know details of the planned design. The solid-state
specifically matched to inductive loads. Whether it is a matter of relays can only conform to their specific technical specifications
frequent actuation of the valves in a filling plant or starting and if they are mounted with appropriate care on an adequately

6
stopping small operating mechanisms in packet distribution dimensioned heat sink.
systems, operation is carried out safely and noiselessly. Mounting solid-state relays directly on a mounting plate made of
Special "low noise" version sheet steel is inadequate in terms of heat dissipation.

Thanks to a special control circuit of the 3RF21 solid-state The following procedure is recommended:
contactors, this special version can be used in public networks • Determine the rated current of the load and the mains voltage
up to 16 A without any additional measures such as interference • Select the relay design and choose a solid-state relay with
suppressor filters. As a result, in terms of emitted interference, higher rated current than the load
it conforms to limit value curve class B according to IEC 60947-4-3.
• Determine the thermal resistance of the proposed heat sink
Function modules • Check the correct relay size with the aid of the diagrams
The 3RF21 and 3RF22 solid-state relays can be expanded • In systems that have high voltage peaks or at voltages of
with various function modules for individual adaptation to 575 V and higher, use of versions with a blocking voltage
applications, see page 6/150 onwards. of 1 600 V is recommended.
3RF21 1-phase solid-state relays (without heat sink)
with a width of 22.5 mm
With its compact design and a width of just 22.5 mm, which is
not exceeded even for currents of up to 88 A, the 3RF21 solid-
state relay offers an ultra-small footprint. The logical connection
method, with the power infeed from above and load connection
from below, ensures tidy installation in the control cabinet.
3RF20 1-phase solid-state relays (without heat sink)
with a width of 45 mm
The solid-state relays with a width of 45 mm provide for
connection of the power supply lead and the load from above.
This makes it easy to replace existing solid-state relays in
existing arrangements. The connection of the control cable is as
space-saving as the 22.5 mm design, as it is simply plugged on.

Siemens IC 10 · 2023 6/121


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF21 solid-state relays, 1-phase, 22.5 mm

■ Technical specifications
More information
System Manual for modular system, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16223/faq
https://support.industry.siemens.com/cs/ww/en/view/60311318

Type 3RF21..-1.... 3RF21..-2.... 3RF21..-3....


Dimensions (W x H x D) mm 22.5 x 85 x 48 mm 22.5 x 85 x 48 mm 22.5 x 85 x 48 mm
H

D
W

General data
Ambient temperature
• During operation, derating from 40 °C °C -25 ... +60
• During storage °C -55 ... +80
Installation altitude m 0 ... 1 000; derating from 1 000
Shock resistance according to IEC 60068-2-27 g/ms 15/11
Vibration resistance according to IEC 60068-2-6 g 2
Degree of protection IP on the front IP20 IP00 (IP20 when using the
according to IEC 60529 3RF2900-3PA88 terminal cover)
Touch protection on the front according to Finger-safe for vertical touching from the front --
6

IEC 60529
Electromagnetic compatibility (EMC)
• Emitted interference
- Conducted interference voltage Class A for industrial applications
according to IEC 60947-4-3
- Emitted, high-frequency interference voltage Class B for residential, business and commercial applications
according to IEC 60947-4-3
• Interference immunity
- Electrostatic discharge kV Contact discharge 4; air discharge 8; behavior criterion 2
according to IEC 61000-4-2
(corresponds to degree of severity 3)
- Induced RF fields MHz 0.15 ... 80; 140 dBµV; behavior criterion 1
according to IEC 61000-4-6
- Burst according to IEC 61000-4-4 kV 2/5.0 kHz; behavior criterion 2
- Surge according to IEC 61000-4-5 kV Conductor - ground 2; conductor - conductor 1; behavior criterion 2
Mounting
• Screws (not included in the scope of supply) 2 x M4
• Tightening torque Nm 1.5
Connection type Screw terminals Spring-loaded terminals Ring cable lug
connection
Connection, main contacts
• Conductor cross-sections
- Solid mm2 2 x (1.5 ... 2.5)1), 2 x (2.5 ... 6)1) 2 x (0.5 ... 2.5) --
- Finely stranded with end sleeve mm2 2 x (1 ... 2.5)1), 2 x (2.5 ... 6)1), 2 x (0.5 ... 1.5) --
1 x 10
- Finely stranded without end sleeve mm2 -- 2 x (0.5 ... 2.5) --
- Solid or stranded, AWG cables AWG 2 x (14 ... 10) 2 x (18 ... 14) --
• Terminal screws M4 -- M5
• Tightening torque Nm 2 ... 2.5 -- 2 ... 2.5
lb.in 7 ... 10.3 -- 7 ... 10.3
• Cable lugs
- According to DIN 46234 -- -- 5-2.5, 5-6, 5-10, 5-16, 5-25
- According to JIS C 2805 -- -- R 2-5, R 5.5-5, R 8-5, R 14-5
- Width, maximum mm -- -- 12
Connection, auxiliary/control contacts
• Conductor cross-sections mm 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.0) 0.5 ... 2.5 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.0)
AWG 20 ... 12 20 ... 12 20 ... 12
• Stripped length mm 7 10 7
• Terminal screw M3 -- M3
• Tightening torque Nm 0.5 ... 0.6 -- 0.5 ... 0.6
lb.in 4.5 ... 5.3 -- 4.5 ... 5.3
1) If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in one of the ranges specified.

6/122 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF21 solid-state relays, 1-phase, 22.5 mm

Type Imax1) Ie according to Ie according to UL/CSA Power loss Minimum load Off-state current
IEC 60947-4-3 current
at Rthha/Tu = 40 °C at Rthha/Tu = 40 °C at Rthha/Tu = 50 °C at Imax
A K/W A K/W A K/W W A mA
Main circuit
3RF2120-..... 20 2.00 20 1.70 20 1.30 28.6 0.1 10
3RF2130-1.... 30 1.45 30 1.45 30 1.25 44.2 0.5 10
3RF2150-1.... 50 0.85 50 0.85 50 0.70 66 0.5 10
3RF2150-2.... 50 0.85 20 2.90 20 2.60 66 0.5 10
3RF2150-3.... 50 0.85 50 0.85 50 0.70 66 0.5 10
3RF2170-1.... 70 0.50 50 1.15 50 1.00 94 0.5 10
3RF2190-1.... 88 0.55 50 1.40 50 0.85 118 0.5 10
3RF2190-2.... 88 0.55 20 3.50 20 2.80 118 0.5 10
3RF2190-3.... 88 0.55 80 0.55 80 0.45 118 0.5 10
1)
The current Imax provides information about the performance of the Note:
solid-state relay. The actual permitted rated operational current Ie can be
smaller depending on the connection method and cooling conditions. The required heat sinks for the corresponding load currents can
be determined from the characteristic curves (see page 6/120,
"More Information"). The minimum thickness values for the
mounting surface must be observed.
Type Rated peak withstand current Itsm I2t value
A A 2s

6
Main circuit
3RF2120-..... 200 200
3RF2130-..A.2 300 450
3RF2130-..A.4 300 450
3RF2130-..A.5 300 450
3RF2130-..A.6 400 800
3RF2150-..... 600 1 800
3RF2170-..A.2 1 200 7 200
3RF2170-..A.4 1 200 7 200
3RF2170-..A.5 1 200 7 200
3RF2170-..A.6 1 150 6 600
3RF2190-..... 1 150 6 600

Type 3RF21..-....2 3RF21..-....4 3RF21..-....5 3RF21..-....6


Main circuit
Rated operational voltage Ue V AC 24 ... 230 48 ... 460 48 ... 600
• Operating range V AC 20 ... 253 40 ... 506 40 ... 660
• Rated frequency Hz 50/60  10%
Rated insulation voltage Ui V 600
Blocking voltage V 800 1 200 1 600
Rate of voltage rise V/µs 1 000

Type 3RF21..-...0. 3RF21..-...1. 3RF21..-...2. 3RF21..-...4.


Control circuit
Method of operation DC operation AC/DC operation AC operation DC operation
Rated control supply voltage Us V 24 24 AC 24 DC 1 105 ... 230 4 ... 30
Rated frequency Hz -- 50/60 -- 50/60  10% --
of the control supply voltage  10%
Control supply voltage, max. V 30 26.5 AC 30 DC 253 30
Typical actuating current mA 15/low power: 91) 20 15 15
Response voltage V 15 14 AC 15 DC 90 4
Drop-out voltage V 5 5 AC 5 DC 40 1
Operating times
• ON-delay ms 1 + max. one 10 + max. one 40 + max. one 1 + max. one
half-wave2) half-wave2) half-wave2) half-wave2)
• OFF-delay ms 1 + max. one 15 + max. one 40 + max. one 1 + max. one
half-wave half-wave half-wave half-wave
1)
Applies to the "low power" version 3RF21..-.AA..-0KN0.
2)
Only for zero-point switching devices.

Siemens IC 10 · 2023 6/123


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF21 solid-state relays, 1-phase, 22.5 mm

■ Selection and ordering data


1-phase solid-state relays (without heat sink) with a width of 22.5 mm
Type current/ Rated control supply Screw terminals PU PS* PG
performance capacity1) voltage Us (UNIT,
SET, M)
Article No. Price
A V per PU
Zero-point switching,
rated operational voltage Ue 24 ... 230 V AC
20 24 DC 3RF2120-1AA02 1 1 unit 41C
30 3RF2130-1AA02 1 1 unit 41C
50 3RF2150-1AA02 1 1 unit 41C
702) 3RF2170-1AA02 1 1 unit 41C
902) 3RF2190-1AA02 1 1 unit 41C
20 110 ... 230 AC 3RF2120-1AA22 1 1 unit 41C
30 3RF2130-1AA22 1 1 unit 41C
50 3RF2150-1AA22 1 1 unit 41C
702) 3RF2170-1AA22 1 1 unit 41C
902) 3RF2190-1AA22 1 1 unit 41C
3RF2120-1AA02 20 4 ... 30 DC 3RF2120-1AA42 1 1 unit 41C
30 3RF2130-1AA42 1 1 unit 41C
Zero-point switching,
rated operational voltage Ue 48 ... 460 V AC
6

20 24 DC 3RF2120-1AA04 1 1 unit 41C


30 3RF2130-1AA04 1 1 unit 41C
50 3RF2150-1AA04 1 1 unit 41C
702) 3RF2170-1AA04 1 1 unit 41C
902) 3RF2190-1AA04 1 1 unit 41C
20 24 AC/DC 3RF2150-1AA14 1 1 unit 41C
20 110 ... 230 AC 3RF2120-1AA24 1 1 unit 41C
30 3RF2130-1AA24 1 1 unit 41C
50 3RF2150-1AA24 1 1 unit 41C
702) 3RF2170-1AA24 1 1 unit 41C
902) 3RF2190-1AA24 1 1 unit 41C
Zero-point switching,
rated operational voltage Ue 48 ... 600 V AC
70 24 DC low power 3RF2170-1AA05-0KN0 1 1 unit 41C
20 4 ... 30 DC 3RF2120-1AA45 1 1 unit 41C
30 3RF2130-1AA45 1 1 unit 41C
50 3RF2150-1AA45 1 1 unit 41C
702) 3RF2170-1AA45 1 1 unit 41C
902) 3RF2190-1AA45 1 1 unit 41C
Zero-point switching · Blocking voltage 1 600 V,
rated operational voltage Ue 48 ... 600 V AC
30 24 DC 3RF2130-1AA06 1 1 unit 41C
50 3RF2150-1AA06 1 1 unit 41C
702) 3RF2170-1AA06 1 1 unit 41C
902) 3RF2190-1AA06 1 1 unit 41C
30 110 ... 230 AC 3RF2130-1AA26 1 1 unit 41C
50 3RF2150-1AA26 1 1 unit 41C
702) 3RF2170-1AA26 1 1 unit 41C
902) 3RF2190-1AA26 1 1 unit 41C
1) The type current provides information about the performance capacity of the Other rated control supply voltages on request.
solid-state relay. The actual permitted rated operational current Ie can be
smaller depending on the connection method and cooling conditions. Accessories, see page 6/127.
2) Please note that this version with an M4 screw connection can only
be used for a rated current of up to approx. 50 A and a conductor
cross-section of 10 mm2.
Please use the 3RF21 solid-state relays with ring cable lug connections
for these currents, see page 6/126.

* You can order this quantity or a multiple thereof.


6/124 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF21 solid-state relays, 1-phase, 22.5 mm

Type current/ Rated control supply Screw terminals PU PS* PG


performance capacity1) voltage Us (UNIT,
SET, M)
Article No. Price
A V per PU
Instantaneous switching,
rated operational voltage Ue 24 ... 230 V AC
50 110 ... 230 AC 3RF2150-1BA22 1 1 unit 41C

Instantaneous switching,
rated operational voltage Ue 48 ... 460 V AC
20 24 DC 3RF2120-1BA04 1 1 unit 41C
30 3RF2130-1BA04 1 1 unit 41C
50 3RF2150-1BA04 1 1 unit 41C
702) 3RF2170-1BA04 1 1 unit 41C
902) 3RF2190-1BA04 1 1 unit 41C
Instantaneous switching · Blocking voltage 1 600 V,
rated operational voltage Ue 48 ... 600 V AC
50 24 DC 3RF2150-1BA06 1 1 unit 41C

Low noise3) · Zero-point switching,


rated operational voltage Ue 48 ... 460 V AC
702) 24 DC 3RF2170-1CA04 1 1 unit 41C
1) The type current provides information about the performance capacity of the 3) See page 6/121.

6
solid-state relay. The actual permitted rated operational current Ie can be
smaller depending on the connection method and cooling conditions. Other rated control supply voltages on request.
2) Please note that this version with an M4 screw connection can only
Accessories, see page 6/127.
be used for a rated current of up to approx. 50 A and a conductor
cross-section of 10 mm2.
Please use the 3RF21 solid-state relays with ring cable lug connections
for these currents, see page 6/126.

Type current/ Rated control supply Spring-loaded PU PS* PG


performance capacity1) voltage Us terminals (UNIT,
SET, M)
Article No. Price
A V per PU
Zero-point switching,
rated operational voltage Ue 24 ... 230 V AC
20 24 DC 3RF2120-2AA02 1 1 unit 41C
502) 3RF2150-2AA02 1 1 unit 41C
902) 3RF2190-2AA02 1 1 unit 41C
20 110 ... 230 AC 3RF2120-2AA22 1 1 unit 41C
502) 3RF2150-2AA22 1 1 unit 41C
902) 3RF2190-2AA22 1 1 unit 41C
20 4 ... 30 DC 3RF2120-2AA42 1 1 unit 41C

3RF2120-2AA02
Zero-point switching,
rated operational voltage Ue 48 ... 460 V AC
20 24 DC 3RF2120-2AA04 1 1 unit 41C
502) 3RF2150-2AA04 1 1 unit 41C
902) 3RF2190-2AA04 1 1 unit 41C
502) 24 AC/DC 3RF2150-2AA14 1 1 unit 41C
20 110 ... 230 AC 3RF2120-2AA24 1 1 unit 41C
502) 3RF2150-2AA24 1 1 unit 41C
902) 3RF2190-2AA24 1 1 unit 41C
Zero-point switching,
rated operational voltage Ue 48 ... 600 V AC
20 4 ... 30 DC 3RF2120-2AA45 1 1 unit 41C

Zero-point switching · Blocking voltage 1 600 V,


rated operational voltage Ue 48 ... 600 V AC
502) 24 DC 3RF2150-2AA06 1 1 unit 41C
902) 3RF2190-2AA06 1 1 unit 41C
502) 110 ... 230 AC 3RF2150-2AA26 1 1 unit 41C
902) 3RF2190-2AA26 1 1 unit 41C
1) The type current provides information about the performance capacity of the Other rated control supply voltages on request.
solid-state relay. The actual permitted rated operational current Ie can be
smaller depending on the connection method and cooling conditions. Accessories, see page 6/127.
2) Please note that the version with spring-loaded terminals can only be used
for a rated current of up to approx. 20 A and a conductor cross-section of
2.5 mm2. Higher currents can be achieved by connecting two conductors
per terminal.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/125
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF21 solid-state relays, 1-phase, 22.5 mm

Type current/ Rated control supply Ring cable lug PU PS* PG


performance capacity1) voltage Us connection (UNIT,
SET, M)
Article No. Price
A V per PU
Zero-point switching,
rated operational voltage Ue 24 ... 230 V AC
20 24 DC 3RF2120-3AA02 1 1 unit 41C
50 3RF2150-3AA02 1 1 unit 41C
90 3RF2190-3AA02 1 1 unit 41C
20 110 ... 230 AC 3RF2120-3AA22 1 1 unit 41C
50 3RF2150-3AA22 1 1 unit 41C
90 3RF2190-3AA22 1 1 unit 41C

3RF2120-3AA02
Zero-point switching,
rated operational voltage Ue 48 ... 460 V AC
20 24 DC 3RF2120-3AA04 1 1 unit 41C
50 3RF2150-3AA04 1 1 unit 41C
90 3RF2190-3AA04 1 1 unit 41C
20 110 ... 230 AC 3RF2120-3AA24 1 1 unit 41C
6

50 3RF2150-3AA24 1 1 unit 41C


90 3RF2190-3AA24 1 1 unit 41C
90 4 ... 30 DC 3RF2190-3AA44 1 1 unit 41C
Zero-point switching · Blocking voltage 1 600 V,
rated operational voltage Ue 48 ... 600 V AC
50 24 DC 3RF2150-3AA06 1 1 unit 41C
90 3RF2190-3AA06 1 1 unit 41C
50 110 ... 230 AC 3RF2150-3AA26 1 1 unit 41C
90 3RF2190-3AA26 1 1 unit 41C
1)
The type current provides information about the performance capacity of the Other rated control supply voltages on request.
solid-state relay. The actual permitted rated operational current Ie can be
smaller depending on the connection method and cooling conditions. Accessories, see page 6/127.

* You can order this quantity or a multiple thereof.


6/126 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF21 solid-state relays, 1-phase, 22.5 mm

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Terminal covers
Ring cable lug
connection
Terminal covers 3RF2900-3PA88 1 10 units 41C
For 3RF21 solid-state relays with ring cable lug
connection
With this terminal cover, degree of protection IP20
can be achieved on the front with a ring cable lug
connection. It can also be used for screw terminals
after simple adaptation.

3RF2900-3PA88
Control connectors
Screw terminals

Replacement control connectors 3RF2900-1TA88 1 50 units 41C


For 3RF20 to 3RF22 solid-state relays
With screw terminals

6
3RF2900-1TA88
Spring-loaded
terminals
Replacement control connectors 3RF2900-2TA88 1 50 units 41C
For 3RF20 to 3RF22 solid-state relays
With spring-loaded terminals

3RF2900-2TA88
Control connectors 3RF2900-2TB88 1 10 units 41C
For 3RF20 to 3RF22 solid-state relays
With spring-loaded terminals
With two clamping points per contact

3RF2900-2TB88
Tools for opening spring-loaded terminals
Screwdrivers 3RA2908-1A 1 1 unit 41B
For all SIRIUS devices
With spring-loaded terminals
Length approx. 200 mm,
size 3.0 mm x 0.5 mm,
3RA2908-1A titanium gray/black,
partially insulated
Blank labels
Unit labeling plates
For SIRIUS devices1)
10 mm × 7 mm, titanium gray 3RT2900-1SB10 100 816 41B
units
20 mm × 7 mm, titanium gray 3RT2900-1SB20 100 340 41B
IC01_00181

units
Adhesive labels
3RT2900-1SB20 For SIRIUS devices
19 mm × 6 mm, titanium gray 3RT2900-1SB60 100 3060 41B
units
1) PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/127
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF20 solid-state relays, 1-phase, 45 mm

■ Technical specifications
More information
System Manual for modular system, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16223/faq
https://support.industry.siemens.com/cs/ww/en/view/60311318

Type 3RF20..-1.... 3RF20..-4....


Dimensions (W x H x D) mm 45 x 58 x 48 45 x 58 x 48

D
W

General data
Ambient temperature
• During operation, derating from 40 °C °C -25 ... +60
• During storage °C -55 ... +80
Installation altitude m 0 ... 1 000; derating from 1 000
Shock resistance according to IEC 60068-2-27 g/ms 15/11
Vibration resistance according to IEC 60068-2-6 g 2
Degree of protection IP on the front IP20
according to IEC 60529
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching from the front
6

Electromagnetic compatibility (EMC)


• Emitted interference
- Conducted interference voltage Class A for industrial applications
according to IEC 60947-4-3
- Emitted, high-frequency interference voltage Class B for residential, business and commercial applications
according to IEC 60947-4-3
• Interference immunity
- Electrostatic discharge kV Contact discharge 4; air discharge 8; behavior criterion 2
according to IEC 61000-4-2
(corresponds to degree of severity 3)
- Induced RF fields MHz 0.15 ... 80; 140 dBµV; behavior criterion 1
according to IEC 61000-4-6
- Burst according to IEC 61000-4-4 kV 2/5.0 kHz; behavior criterion 2
- Surge according to IEC 61000-4-5 kV Conductor - ground 2; conductor - conductor 1; behavior criterion 2
Mounting
• Screws (not included in the scope of supply) 2 x M4
• Tightening torque Nm 1.5
Connection type Screw terminals Spring-loaded terminals

Connection, main contacts


• Conductor cross-sections
- Solid mm2 2 x (1.5 ... 2.5)1), 2 x (2.5 ... 6)1) --
- Finely stranded with end sleeve mm2 2 x (1 ... 2.5)1), 2 x (2.5 ... 6)1), 1 x 10 --
- Solid or stranded, AWG cables AWG 2 x (14 ... 10) --
• Terminal screw M4 --
• Tightening torque Nm 2 ... 2.5 --
lb.in 7 ... 10.3 --
Connection, auxiliary/control contacts
• Conductor cross-sections mm2 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.0) 0.5 ... 2.5
AWG 20 ... 12 20 ... 12
• Stripped length mm 7 10
• Terminal screw M3 --
• Tightening torque Nm 0.5 ... 0.6 --
lb.in 4.5 ... 5.3 --
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in one of the ranges specified.

6/128 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF20 solid-state relays, 1-phase, 45 mm

Type Imax1) Ie according to Ie according to Power loss Minimum load Off-state current
IEC 60947-4-3 UL/CSA current
at Rthha/Tu = 40 °C at Rthha/Tu = 40 °C at Rthha/Tu = 50 °C at Imax
A K/W A K/W A K/W W A mA
Main circuit
3RF2020-1.A.. 20 2.00 20 1.70 20 1.30 28.6 0.1 10
3RF2030-1.A.. 30 1.45 30 1.45 30 1.25 44.2 0.5 10
3RF2050-1.A.. 50 0.85 50 0.85 50 0.70 66 0.5 10
3RF2070-1.A.. 70 0.50 50 1.15 50 1.00 94 0.5 10
3RF2090-1.A.. 88 0.55 50 1.40 50 1.00 118 0.5 10
1) The current Imax provides information about the performance of the Note:
solid-state relay. The actual permitted rated operational current Ie can be
smaller depending on the connection method and cooling conditions. The required heat sinks for the corresponding load currents can
be determined from the characteristic curves (see page 6/120,
"More Information"). The minimum thickness values for the
mounting surface must be observed.

Type Rated peak withstand current Itsm I2t value


A A²s
Main circuit
3RF2020-1.A.. 200 200

6
3RF2030-1.A.2 300 450
3RF2030-1.A.4 300 450
3RF2030-1.A.6 400 800
3RF2050-1.A.. 600 1 800
3RF2070-1.A.2 1 200 7 200
3RF2070-1.A.4 1 200 7 200
3RF2070-1.A.5 1 200 7 200
3RF2070-1.A.6 1 150 6 600
3RF2090-1.A.. 1 150 6 600

Type 3RF20.0-1.A.2 3RF20.0-1.A.4 3RF20.0-1.A.5 3RF20.0-1.A.6


Main circuit
Rated operational voltage Ue V AC 24 ... 230 48 ... 460 48 ... 600
• Operating range V AC 20 ... 253 40 ... 506 40 ... 660
• Rated frequency Hz 50/60  10%
Rated insulation voltage Ui V 600
Blocking voltage V 800 1 200 1 600
Rate of voltage rise V/s 1 000

Type 3RF20.0-1.A0. 3RF20.0-1.A2. 3RF20.0-1.A4.


Control circuit
Method of operation DC operation AC operation DC operation
Rated control supply voltage Us V 24 110 ... 230 4 … 30
Rated frequency of the control Hz -- 50/60  10% --
supply voltage
Control supply voltage, max. V 30 253 30
Typical actuating current mA 15 15 15
Response voltage V 15 90 4
Drop-out voltage V 5 40 1
Operating times
• ON-delay ms 1 + max. one half-wave1) 40 + max. one half-wave1) 1 + max. one half-wave1)
• OFF-delay ms 1 + max. one half-wave 40 + max. one half-wave 1 + max. one half-wave
1) Only for zero-point switching devices.

Siemens IC 10 · 2023 6/129


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF20 solid-state relays, 1-phase, 45 mm

■ Selection and ordering data


1-phase solid-state relays (without heat sink) with a width of 45 mm
Type current/ Rated control supply Screw terminals PU PS* PG
performance capacity1) voltage Us (UNIT,
SET, M)
Article No. Price
A V per PU
Zero-point switching,
rated operational voltage Ue 24 ... 230 V AC
20 24 DC 3RF2020-1AA02 1 1 unit 41C
30 3RF2030-1AA02 1 1 unit 41C
50 3RF2050-1AA02 1 1 unit 41C
702) 3RF2070-1AA02 1 1 unit 41C
902) 3RF2090-1AA02 1 1 unit 41C
20 110 ... 230 AC 3RF2020-1AA22 1 1 unit 41C
30 3RF2030-1AA22 1 1 unit 41C
50 3RF2050-1AA22 1 1 unit 41C
702) 3RF2070-1AA22 1 1 unit 41C
902) 3RF2090-1AA22 1 1 unit 41C
3RF2020-1AA02 20 4 ... 30 DC 3RF2020-1AA42 1 1 unit 41C
30 3RF2030-1AA42 1 1 unit 41C
Zero-point switching,
rated operational voltage Ue 48 ... 460 V AC
6

20 24 DC 3RF2020-1AA04 1 1 unit 41C


30 3RF2030-1AA04 1 1 unit 41C
50 3RF2050-1AA04 1 1 unit 41C
702) 3RF2070-1AA04 1 1 unit 41C
902) 3RF2090-1AA04 1 1 unit 41C
20 110 ... 230 AC 3RF2020-1AA24 1 1 unit 41C
30 3RF2030-1AA24 1 1 unit 41C
50 3RF2050-1AA24 1 1 unit 41C
702) 3RF2070-1AA24 1 1 unit 41C
902) 3RF2090-1AA24 1 1 unit 41C
50 4 ... 30 DC 3RF2050-1AA44 1 1 unit 41C
Zero-point switching,
rated operational voltage Ue 48 ... 600 V AC
20 4 ... 30 DC 3RF2020-1AA45 1 1 unit 41C
50 3RF2050-1AA45 1 1 unit 41C
702) 3RF2070-1AA45 1 1 unit 41C
902) 3RF2090-1AA45 1 1 unit 41C
Zero-point switching · Blocking voltage 1 600 V,
rated operational voltage Ue 48 ... 600 V AC
30 24 DC 3RF2030-1AA06 1 1 unit 41C
50 3RF2050-1AA06 1 1 unit 41C
702) 3RF2070-1AA06 1 1 unit 41C
902) 3RF2090-1AA06 1 1 unit 41C
30 110 ... 230 AC 3RF2030-1AA26 1 1 unit 41C
50 3RF2050-1AA26 1 1 unit 41C
702) 3RF2070-1AA26 1 1 unit 41C
902) 3RF2090-1AA26 1 1 unit 41C
Instantaneous switching,
rated operational voltage Ue 48 ... 460 V AC
30 24 DC 3RF2030-1BA04 1 1 unit 41C

1)
The type current provides information about the performance capacity of Accessories, see page 6/127.
the solid-state relay. The actual permitted rated operational current Ie can
be smaller depending on the connection method and cooling conditions.
2)
Please note that this version with an M4 screw connection can only
be used for a rated current of up to approx. 50 A and a conductor
cross-section of 10 mm2.

* You can order this quantity or a multiple thereof.


6/130 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF20 solid-state relays, 1-phase, 45 mm

Type current/ Rated control supply Screw terminals + PU PS* PG


performance capacity1) voltage Us spring-loaded (UNIT,
terminals SET, M)
(control current side)
Article No. Price
A V per PU
Zero-point switching,
rated operational voltage Ue 24 ... 230 V AC
50 24 DC 3RF2050-4AA02 1 1 unit 41C

3RF2050-4AA02
1)
The type current provides information about the performance capacity of Accessories, see page 6/127.
the solid-state relay. The actual permitted rated operational current Ie can
be smaller depending on the connection method and cooling conditions.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/131
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF22 solid-state relays, 3-phase, 45 mm

■ Technical specifications
More information
System Manual for modular system, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16223/faq
https://support.industry.siemens.com/cs/ww/en/view/60311318

Type 3RF22..-1.... 3RF22..-2.... 3RF22..-3....


Dimensions (W x H x D) mm 45 x 95 x 47 45 x 95 x 47 45 x 95 x 47
H

D
W

General data
Ambient temperature
• During operation, derating from 40 °C °C -25 ... +60
• During storage °C -55 ... +80
Installation altitude m 0 ... 1 000; > 1 000 ask Technical Support
Shock resistance according to IEC 60068-2-27 g/ms 15/11
Vibration resistance according to IEC 60068-2-6 g 2
Degree of protection IP on the front IP20 IP00
according to IEC 60529
Touch protection on the front Finger-safe for vertical touching from the front --
according to IEC 60529
6

Insulation strength at 50/60 Hz V rms 4 000


(main/control circuit to floor)
Electromagnetic compatibility (EMC)
• Emitted interference
- Conducted interference voltage Class A for industrial applications1)
according to IEC 60947-4-3
• Interference immunity
- Electrostatic discharge kV Contact discharge 4; air discharge 8; behavior criterion 2
according to IEC 61000-4-2
(corresponds to degree of severity 3)
- Induced RF fields according to IEC 61000-4-6 MHz 0.15 ... 80; 140 dBµV; behavior criterion 1
- Burst according to IEC 61000-4-4 kV 2/5.0 kHz; behavior criterion 2
- Surge according to IEC 61000-4-5 kV Conductor - ground 2; conductor - conductor 1; behavior criterion 2
Mounting
• Screws (not included in the scope of supply) 2 x M4
• Tightening torque Nm 1.5
Connection type Screw terminals Spring-loaded Ring cable lug
terminals connection
Connection, main contacts
• Conductor cross-sections
- Solid mm2 2 x (1.5 ... 2.5)2), 2 x (2.5 ... 6)2) 2 x (0.5 ... 2.5) --
- Finely stranded with end sleeve mm2 2 x (1 ... 2.5)2), 2 x (2.5 ... 6)2), 2 x (0.5 ... 1.5) --
1 x 10
- Finely stranded without end sleeve mm2 -- 2 x (0.5 ... 2.5) --
- Solid or stranded, AWG cables AWG 2 x (14 ... 10) 2 x (18 ... 14) --
• Stripped length mm 10 10 --
• Terminal screws M4 -- M5
- Tightening torque, Nm 2 ... 2.5 2 ... 2.5
 5 ... 6 mm, PZ 2 lb.in 18 ... 22 18 ... 22
• Cable lugs
- According to DIN 46234 -- -- 5-2.5 ... 5-25
- According to JIS C 2805 -- -- R 2-5 ... R 14-5
- Width, maximum mm -- -- 12
Connection, auxiliary/control contacts
• Conductor cross-sections, mm 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.0) 0.5 ... 2.5 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.0)
with or without end sleeve AWG 20 ... 12 20 ... 12 20 ... 12
• Stripped length mm 7 10 7
• Terminal screw M3 -- M3
- Tightening torque, Nm 0.5 ... 0.6 0.5 ... 0.6
 3.5 mm, PZ 1 lb.in 4.5 ... 5.3 4.5 ... 5.3
1)
These products were built as Class A devices. The use of these devices in
residential areas could result in radio interference. In this case it may be
required to introduce additional interference suppression measures.
2) If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in one of the ranges specified.

6/132 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF22 solid-state relays, 3-phase, 45 mm

Type Imax1) Ie according to Ie according to UL/CSA Power loss Minimum load Max. off-state
IEC 60947-4-3 current current
at Rthha/Tu = 40 °C at Rthha/Tu = 40 °C at Rthha/Tu = 50 °C at Imax
A K/W A K/W A K/W W A mA
Main circuit
3RF2230-1AB.. 30 0.80 30 0.80 30 0.65 81 0.5 10
3RF2230-2AB.. 20 1.36 20 1.15
3RF2230-3AB.. 30 0.80 30 0.65
3RF2255-1AB.. 55 0.25 50 0.35 50 0.15 151 0.5 10
3RF2255-2AB.. 20 1.83 20 1.58
3RF2255-3AB.. 55 0.25 55 0.15
3RF2230-1AC.. 30 0.45 30 0.45 30 0.35 122 0.5 10
3RF2230-2AC.. 20 0.86 20 0.72
3RF2230-3AC.. 30 0.45 30 0.35
3RF2255-1AC.. 55 0.14 50 0.20 50 0.12 226 0.5 10
3RF2255-2AC.. 20 1.19 20 1.02
3RF2255-3AC.. 55 0.14 55 0.12
1)
The current Imax provides information about the performance of the Note:
solid-state relay. The actual permitted rated operational current Ie can
be smaller depending on the connection method and cooling conditions. The required heat sinks for the corresponding load currents can
be determined from the characteristic curves (see page 6/120,
"More Information"). The minimum thickness values for the
mounting surface must be observed.

6
Type Rated peak withstand current Itsm I2t value
A A 2s
Main circuit
3RF2230-....5 300 450
3RF2255-....5 600 1 800

Type 3RF22..-.AB.5 3RF22..-.AC.5


Main circuit
Controlled phases 2-phase 3-phase
Rated operational voltage Ue V AC 48 ... 600
• Operating range V AC 40 ... 660
• Rated frequency Hz 50/60  10%
Rated insulation voltage Ui V 600
Rated impulse withstand voltage Uimp kV 6
Blocking voltage V 1 200
Rate of voltage rise V/µs 1 000

Type 3RF22..-.A.3. 3RF22..-.A.4.


Control circuit
Method of operation AC operation DC operation
Rated control supply voltage Us V 110 4 ... 30
Rated frequency Hz 50/60  10% --
of the control supply voltage
Control supply voltage, max. V 121 30
Typical actuating current mA 15 30
Response voltage V 90 4
Drop-out voltage V < 40 1
Operating times
• ON-delay ms 40 + max. one half-wave 1 + max. one half-wave
• OFF-delay ms 40 + max. one half-wave 1 + max. one half-wave

Siemens IC 10 · 2023 6/133


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state relays > SIRIUS 3RF22 solid-state relays, 3-phase, 45 mm

■ Selection and ordering data


Type current/ Rated control supply Screw terminals PU PS* PG
performance capacity1) voltage Us (UNIT,
SET, M)
Article No. Price
A V per PU
Zero-point switching,
rated operational voltage Ue 48 ... 600 V AC
2-phase controlled
30 110 AC 3RF2230-1AB35 1 1 unit 41C
552) 3RF2255-1AB35 1 1 unit 41C
30 4 ... 30 DC 3RF2230-1AB45 1 1 unit 41C
552) 3RF2255-1AB45 1 1 unit 41C
3-phase controlled
30 110 AC 3RF2230-1AC35 1 1 unit 41C
552) 3RF2255-1AC35 1 1 unit 41C
3RF2230-1AB35 30 4 ... 30 DC 3RF2230-1AC45 1 1 unit 41C
552) 3RF2255-1AC45 1 1 unit 41C
1)
The type current provides information about the performance capacity of Accessories, see page 6/127.
the solid-state relay. The actual permitted rated operational current Ie can
be smaller depending on the connection method and cooling conditions.
6

2)
Please note that the version with an M4 screw connection can only be used
for a rated current of up to approx. 50 A and a conductor cross-section
of 10 mm2.
Please use the 3RF22 solid-state relays with ring cable lug connections for
these currents.

Type current/ Rated control supply Spring-loaded PU PS* PG


performance capacity1) voltage Us terminals (UNIT,
SET, M)
Article No. Price
A V per PU
Zero-point switching,
rated operational voltage Ue 48 ... 600 V AC
2-phase controlled
302) 4 ... 30 DC 3RF2230-2AB45 1 1 unit 41C
552) 3RF2255-2AB45 1 1 unit 41C
3-phase controlled
302) 4 ... 30 DC 3RF2230-2AC45 1 1 unit 41C
552) 3RF2255-2AC45 1 1 unit 41C

3RF2230-2AB45
1) The type current provides information about the performance capacity of Accessories, see page 6/127.
the solid-state relay. The actual permitted rated operational current Ie can
be smaller depending on the connection method and cooling conditions.
2) Please note that the version with spring-loaded terminals can only be used
for a rated current of up to approx. 20 A and a conductor cross-section of
2.5 mm2. Higher currents can be achieved by connecting two conductors
per terminal.

Type current/ Rated control supply Ring cable lug PU PS* PG


performance capacity1) voltage Us connection (UNIT,
SET, M)
Article No. Price
A V per PU
Zero-point switching,
rated operational voltage Ue 48 ... 600 V AC
2-phase controlled
30 4 ... 30 DC 3RF2230-3AB45 1 1 unit 41C
55 3RF2255-3AB45 1 1 unit 41C
3-phase controlled
30 4 ... 30 DC 3RF2230-3AC45 1 1 unit 41C
55 3RF2255-3AC45 1 1 unit 41C

3RF2230-3AB45
1)
The type current provides information about the performance capacity of the Accessories, see page 6/127.
solid-state relay. The actual permitted rated operational current Ie can be
smaller depending on the connection method and cooling conditions.

* You can order this quantity or a multiple thereof.


6/134 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > General data

■ Overview
Solid-state contactors (with integrated heat sink) In systems that have high voltage peaks or at voltages of 575 V
and higher, use of versions with a blocking voltage of 1 600 V is
The solid-state contactors are available in two different versions: recommended.
• 3RF23 1-phase solid-state contactors: Their compact design
with optimized heat sink enables small complete units with The following miniature circuit breakers with a B characteristic
currents up to 70 A. and 10 kA or 6 kA breaking capacity protect the 3RF23..-.DA..
solid-state contactors in the event of short circuits on the load
• 3RF24 3-phase solid-state contactors: Their compact design and the specified conductor cross-sections and lengths:
with optimized heat sink enables the provision of small
complete units with currents up to 50 A. Rated current of the Example of Max. Minimum
miniature circuit type1) conductor cable length from
The complete units consist of a solid-state relay plus optimized breaker cross- contactor to load
heat sink, and are therefore ready to use. They offer defined section
rated currents to make selection as easy as possible. Like all 6A 5SY4106-6 1 mm2 5m
of our solid-state switching devices, one of their particular 10 A 5SY4110-6 1.5 mm2 8m
advantages is their compact and space-saving design.
16 A 5SY4116-6 1.5 mm2 12 m
Thanks to optimized power electronics, versions of 3RF2310 to 2.5 mm2 20 m
3RF2330 solid-state contactors can be mounted side-by-side 20 A 5SY4120-6 2.5 mm2 20 m
without derating, see product information or product data sheets
25 A 5SY4125-6 2.5 mm2 26 m
for the individual products.
1)
The miniature circuit breakers can be used up to a maximum rated voltage
Note: of 480 V!

6
Due to a special mounting foot for versions 3RF2310 to 3RF2330
and 3RF2410, snapping onto grounded DIN rails or mounting 3/N/PE 50 Hz 230/400 V 3/N/PE 50 Hz 230/400 V
on a grounded mounting plate simultaneously provides safe L1 L1
grounding of the heat sink. Additional grounding is no longer L2 L2
necessary in this case.
With other types of mounting, an additional ground connection L3 L3
to the heat sink can be established by means of a screw terminal N N
connection.
3RF23 1-phase solid-state contactors with heat sink F1 F1 F2

Version for resistive loads "zero-point switching" K1 K1

This standard version is often used for switching heaters on and off. 1 L 1 L

Version for inductive loads "instantaneous switching"


2 T 2 T
In this version, the solid-state contactor is specifically matched
to inductive loads. Whether it is a matter of frequent actuation
line

line
line

of the valves in a filling plant or starting and stopping small I,A I,A
operating mechanisms in packet distribution systems, operation
NSB0_01473b

is carried out safely and noiselessly.


Special "low noise" version
Thanks to a special control circuit, this special version can R1 R1
be used in public networks up to 16 A without any additional
measures such as interference suppressor filters. As a result, Solid-state contactor protection
in terms of emitted interference, it conforms to limit value curve
class B according to IEC 60947-4-3. The setup and installation above can also be used for the
solid-state relays with an I2t value of at least 6 600 A2s.
Special "short-circuit-proof" version
Function modules
Skillful matching of the power semiconductor with the
performance capacity of the solid-state contactor means The 3RF23 solid-state contactors can be expanded with various
that "short-circuit strength" can be achieved with a standard function modules for individual adaptation to applications,
miniature circuit breaker. In combination with a B MCB or see page 6/150 onwards.
a conventional line protection fuse, the result is a short-circuit-
proof feeder. 3RF24 3-phase solid-state contactors with heat sink

In order to achieve problem-free short-circuit protection by The 3-phase solid-state contactors for resistive loads up to 50 A
means of miniature circuit breakers, however, certain constraints are available with
must be observed. As the magnitude and duration of the short- • 2-phase control (suitable in particular for circuits without
circuit current are determined not only by the short-circuit connection to the neutral conductor) and
breaking response of the miniature circuit breaker but also the • 3-phase control (suitable for star circuits with connection to
properties of the wiring system, such as the internal resistance the neutral conductor or for applications in which the system
of the input to the network and damping by switching devices requires all phases to be switched)
and cables, particular attention must also be paid to these
parameters. The necessary cable lengths are therefore shown The converter function module can be snapped onto both
for the main factor, the line resistance, in the following table. versions for the simple power control of loads in a three-phase
network by means of analog signals.
Note:
Checking the correct solid-state contactor size with the aid of
the rated current diagram, taking account of the installation
conditions, is recommended.

Siemens IC 10 · 2023 6/135


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF23 solid-state contactors, 1-phase

■ Technical specifications
More information
System Manual for modular system, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16223/faq
https://support.industry.siemens.com/cs/ww/en/view/60311318

Type 3RF23..-.A... 3RF23..-.B... 3RF23..-.C... 3RF23..-.D...


Dimensions (W x H x D) See page 6/137
General data
Ambient temperature
• During operation, derating from 40 °C °C -25 ... +60
• During storage °C -55 ... +80
Installation altitude m 0 ... 1 000; derating from 1 000
Shock resistance according to IEC 60068-2-27 g/ms 15/11
Vibration resistance according to IEC 60068-2-6 g 2
Degree of protection IP on the front
according to IEC 60529
• Screw terminals and spring-loaded terminals IP20
• Ring cable lug connection IP00 (IP20 when using the 3RF2900-3PA88 terminal cover)
Touch protection on the front
according to IEC 60529
6

• Screw terminals and spring-loaded terminals Finger-safe for vertical touching from the front
• Ring cable lug connection Finger-safe for vertical touching from the front when using the 3RF2900-3PA88 terminal cover
Electromagnetic compatibility (EMC)
• Emitted interference according to IEC 60947-4-3
- Conducted interference voltage Class A for industrial applications Class A for industrial Class A for industrial
applications; applications
Class B for residential,
business and
commercial applica-
tions up to 16 A,
AC-51 low noise
- Emitted, high-frequency interference voltage Class B for residential, business and commercial applications
• Interference immunity
- Electrostatic discharge kV Contact discharge 4; air discharge 8; behavior criterion 2
according to IEC 61000-4-2
(corresponds to degree of severity 3)
- Induced RF fields according to IEC 61000-4-6 MHz 0.15 ... 80; 140 dBµV; behavior criterion 1
- Burst according to IEC 61000-4-4 kV 2/5.0 kHz; behavior criterion 2
- Surge according to IEC 61000-4-5 kV Conductor - ground 2; conductor - conductor 1; behavior criterion 2

Type 3RF23..-1.... 3RF23..-2.... 3RF23..-3....


General data
Connection type Screw terminals Spring-loaded terminals Ring cable lug
connection
Connection, main contacts
• Conductor cross-section
- Solid mm2 2 x (1.5 ... 2.5)1), 2 x (2.5 ... 6)1) 2 x (0.5 ... 2.5) --
- Finely stranded with end sleeve mm2 2 x (1 ... 2.5)1), 2 x (2.5 ... 6)1), 2 x (0.5 ... 1.5) --
1 x 10
- Finely stranded without end sleeve mm2 -- 2 x (0.5 ... 2.5) --
- Solid or stranded, AWG cables AWG 2 x (14 ... 10) 2 x (18 ... 14) --
• Terminal screws M4 -- M5
• Tightening torque Nm 2 ... 2.5 -- 2 ... 2.5
lb.in 7 ... 10.3 -- 7 ... 10.3
• Cable lugs
- According to DIN 46234 -- -- 5-2.5, 5-6, 5-10, 5-16, 5-25
- According to JIS C 2805 -- -- R 2-5, R 5.5-5, R 8-5, R 14-5
- Width, maximum mm -- -- 12
Connection, auxiliary/control contacts
• Conductor cross-section mm 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.0) 0.5 ... 2.5 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.0)
AWG 20 ... 12 20 ... 12 20 ... 12
• Stripped length mm 7 10 7
• Terminal screw M3 -- M3
• Tightening torque Nm 0.5 ... 0.6 -- 0.5 ... 0.6
lb.in 4.5 ... 5.3 -- 4.5 ... 5.3
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in one of the ranges specified.

6/136 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF23 solid-state contactors, 1-phase

Type 3RF23..-1.... 3RF23..-2.... 3RF23..-3....


General data
Connection type Screw terminals Spring-loaded terminals Ring cable lug connection

Grounding studs Optional,


see also note on page 6/135 about the special mounting foot for safe grounding on DIN rails for versions
3RF2310 to 3RF2330
• Size (standard screw) M5
Permissible mounting position ±10° ±10°

NSB0_01701

Type 3RF23..-....2 3RF23..-....4 3RF23..-....5 3RF23..-....6


Main circuit
Rated operational voltage Ue V AC 24 ... 230 48 ... 460 48 ... 600
• Operating range V AC 20 ... 253 40 ... 506 40 ... 660
• Rated frequency Hz 50/60  10%
Rated insulation voltage Ui V 600

6
Blocking voltage V 800 1 200 1 600
Rate of voltage rise V/µs 1 000

Type 3RF23..-...0. 3RF23..-...1. 3RF23..-...2. 3RF23..-...4.


Control circuit
Method of operation DC operation AC/DC operation AC operation DC operation
Rated control supply voltage Us V 24 DC 24 AC 24 DC 110 ... 230 AC 4 ... 30 DC
Rated frequency Hz -- 50/60 -- 50/60  10% --
of the control supply voltage  10%
Actuating voltage, max. V 30 26.5 AC 30 DC 253 30
Typical actuating current mA 15/low power: 91) 20 20 15 20
Response voltage V 15 14 AC 15 DC 90 4
Drop-out voltage V 5 5 AC 5 DC 40 1
Operating times
• ON-delay ms 1 + max. one 10 + max. one 40 + max. one 1 + max. one
half-wave2) half-wave2) half-wave2) half-wave2)
• OFF-delay ms 1 + max. one 15 + max. one 40 + max. one 1 + max. one
half-wave half-wave half-wave half-wave
1)
Applies to the "low power" version 3RF23..-.AA..-0KN0.
2)
Only for zero-point switching devices.

Type Type current/performance capacity1) Dimensions (W x H x D) incl. heat sink


IAC-51
H

A mm
Main circuit
3RF2310-.AA.. 10.5 22.5 x 95 x 84
3RF2320-.AA.. 20 22.5 x 95 x 116
3RF2320-.CA..
3RF2320-.DA..
3RF2330-.AA.. 30 45 x 95 x 131.5
3RF2330-.CA..
3RF2330-.DA.. 22.5 x 95 x 116
3RF2340-.AA.. 40 67 x 100 x 136
3RF2340-.DA..
3RF2350-.AA.. 50 67 x 100 x 136
3RF2370-.AA.. 70 80 x 100 x 157
1)
The type current provides information about the performance of the
solid-state contactor. The actual permitted rated operational current Ie
can be smaller depending on the installation conditions.

Siemens IC 10 · 2023 6/137


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF23 solid-state contactors, 1-phase

Type Type current AC-51/performance capacity1) Power loss Minimum load Off-state Rated peak I2t value
at Imax according to according to at Imax current current withstand
IEC 60947-4-3 UL/CSA current Itsm
at 40 °C at 40 °C at 50 °C
A A A W A mA A A²s
Main circuit
3RF2310-.AA.2 10.5 7.5 9.6 11 0.1 10 200 200
3RF2310-.AA.4
3RF2310-.AA.5
3RF2310-.AA.6 400 800
3RF2320-.AA.2 20 13.2 17.6 20 0.5 10 600 1 800
3RF2320-.AA.4
3RF2320-.AA.5
3RF2320-.AA.6
3RF2320-.CA.2 25 600 1 800
3RF2320-.CA.4
3RF2320-.DA.2 10 1 150 6 600
3RF2320-.DA.4
3RF2330-.AA.2 30 22 27 33 0.5 10 600 1 800
3RF2330-.AA.4
3RF2330-.AA.5
3RF2330-.AA.6
3RF2330-.CA.2 25 600 1 800
6

3RF2330-.DA.4 18.5 26 33 0.5 10 1 150 6 600


3RF2340-.AA.2 40 33 36 44 0.5 10 1 200 7 200
3RF2340-.AA.4
3RF2340-.AA.5
3RF2340-.AA.6 1 150 6 600
3RF2340-.DA.4 33 30 44 0.5 10 1 150 6 600
3RF2350-.AA.2 50 36 45 54 0.5 10 1 150 6 600
3RF2350-.AA.4
3RF2350-.AA.5
3RF2350-.AA.6
3RF2370-.AA.2 70 70 62 83 0.5 10 1 150 6 600
3RF2370-.AA.4
3RF2370-.AA.5
3RF2370-.AA.6
1)
The type current provides information about the performance of the
solid-state contactor. The actual permitted rated operational current Ie
can be smaller depending on the installation conditions.

Type Type current AC-51/performance Type current AC-15/ Power loss Minimum Off-state Rated peak I2t value
capacity1) performance at Imax load current current withstand
capacity1) current
at Imax according to according 10 x Ie Parameters Itsm
IEC 60947-4-3 to UL/CSA for
at 40 °C at 40 °C at 50 °C 60 ms
A A A A W A mA A A²s
Main circuit
3RF2310-.BA.2 10.5 7.5 9.6 6 1 200 1/h 11 0.1 10 200 200
3RF2310-.BA.4 50%
3RF2310-.BA.6 ON period 400 800
3RF2320-.BA.2 20 13.2 17.6 12 1 200 1/h 20 0.5 10 600 1 800
3RF2320-.BA.4 50%
3RF2320-.BA.6 ON period
3RF2330-.BA.2 30 22 27 15 1 200 1/h 33 0.5 10 600 1 800
3RF2330-.BA.4 50%
3RF2330-.BA.6 ON period
3RF2340-.BA.2 40 33 36 20 1 200 1/h 44 0.5 10 1 200 7 200
3RF2340-.BA.4 50%
3RF2340-.BA.6 ON period 1 150 6 600
3RF2350-.BA.2 50 36 45 25 1 200 1/h 54 0.5 10 1 150 6 600
3RF2350-.BA.4 50%
3RF2350-.BA.6 ON period
3RF2370-.BA.2 70 70 62 27.5 1 200 1/h 83 0.5 10 1 150 6 600
3RF2370-.BA.4 50%
3RF2370-.BA.6 ON period
1) The type current provides information about the performance of the
solid-state contactor. The actual permitted rated operational current Ie
can be smaller depending on the installation conditions.

6/138 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF23 solid-state contactors, 1-phase

■ Selection and ordering data


Selection notes
The solid-state contactors are selected on the basis of details The following procedure is recommended:
of the network, the load and the ambient conditions. As the • Determine the rated current of the load and the mains voltage
solid-state contactors are already equipped with an optimally
matched heat sink, the selection process is considerably • Select a solid-state contactor with the same or higher rated
simpler than that for solid-state relays. current than the load

Type current/ Rated control supply Grounding Screw terminals PU PS* PG


performance voltage Us (UNIT,
capacity1) SET, M)
Imax
Article No. Price
A V per PU
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 24 ... 230 V AC
10.5 24 DC  3RF2310-1AA02 1 1 unit 41C
20  3RF2320-1AA02 1 1 unit 41C
30  3RF2330-1AA02 1 1 unit 41C
40 -- 3RF2340-1AA02 1 1 unit 41C
50 -- 3RF2350-1AA02 1 1 unit 41C
20 24 DC low power  3RF2320-1AA02-0KN0 1 1 unit 41C
10.5 24 AC/DC  3RF2310-1AA12 1 1 unit 41C

6
10.5 110 ... 230 AC  3RF2310-1AA22 1 1 unit 41C
20  3RF2320-1AA22 1 1 unit 41C
30  3RF2330-1AA22 1 1 unit 41C
3RF2310-1 40 -- 3RF2340-1AA22 1 1 unit 41C
50 -- 3RF2350-1AA22 1 1 unit 41C
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 460 V AC
10.5 24 DC  3RF2310-1AA04 1 1 unit 41C
20  3RF2320-1AA04 1 1 unit 41C
30  3RF2330-1AA04 1 1 unit 41C
40 -- 3RF2340-1AA04 1 1 unit 41C
50 -- 3RF2350-1AA04 1 1 unit 41C
10.5 24 DC low power  3RF2310-1AA04-0KN0 1 1 unit 41C
10.5 24 AC/DC  3RF2310-1AA14 1 1 unit 41C
20  3RF2320-1AA14 1 1 unit 41C
30  3RF2330-1AA14 1 1 unit 41C
40 -- 3RF2340-1AA14 1 1 unit 41C
3RF2320-1 50 -- 3RF2350-1AA14 1 1 unit 41C
10.5 110 ... 230 AC  3RF2310-1AA24 1 1 unit 41C
20  3RF2320-1AA24 1 1 unit 41C
30  3RF2330-1AA24 1 1 unit 41C
40 -- 3RF2340-1AA24 1 1 unit 41C
50 -- 3RF2350-1AA24 1 1 unit 41C
10.5 4 ... 30 DC  3RF2310-1AA44 1 1 unit 41C
20  3RF2320-1AA44 1 1 unit 41C
30  3RF2330-1AA44 1 1 unit 41C
 These versions are equipped with a special mounting foot. Snapping them Other rated control supply voltages on request.
onto grounded DIN rails or mounting them on a grounded mounting plate
simultaneously provides safe grounding of the heat sink. Additional Accessories, see page 6/145.
grounding is no longer necessary in this case.
-- With these versions, the ground connection to the heat sink can be
established by means of a screw terminal connection.
1)
The type current provides information about the performance of the
solid-state contactor. The actual permitted rated operational current Ie
can be smaller depending on the installation conditions.
For derating characteristic curves, see page 6/120, "More information".

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/139
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF23 solid-state contactors, 1-phase

Type current/ Rated control supply Grounding Screw terminals PU PS* PG


performance voltage Us (UNIT,
capacity1) SET, M)
Imax
Article No. Price
A V per PU
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 600 V AC
20 110 DC  3RF2320-1AA65 1 1 unit 41C
30 110 ... 230 AC  3RF2330-1AA25 1 1 unit 41C
10.5 4 ... 30 DC  3RF2310-1AA45 1 1 unit 41C
20  3RF2320-1AA45 1 1 unit 41C
30  3RF2330-1AA45 1 1 unit 41C
40 -- 3RF2340-1AA45 1 1 unit 41C
50 -- 3RF2350-1AA45 1 1 unit 41C
Zero-point switching · Integrated heat sink,
blocking voltage 1 600 V,
rated operational voltage Ue 48 ... 600 V AC
10.5 24 DC  3RF2310-1AA06 1 1 unit 41C
20  3RF2320-1AA06 1 1 unit 41C
30  3RF2330-1AA06 1 1 unit 41C
40 -- 3RF2340-1AA06 1 1 unit 41C
50 -- 3RF2350-1AA06 1 1 unit 41C
10.5 110 ... 230 AC  3RF2310-1AA26 1 1 unit 41C
6

20  3RF2320-1AA26 1 1 unit 41C


30  3RF2330-1AA26 1 1 unit 41C
40 -- 3RF2340-1AA26 1 1 unit 41C
50 -- 3RF2350-1AA26 1 1 unit 41C
3RF2330-1
Low noise2),
zero-point switching · Integrated heat sink,
rated operational voltage Ue 24 ... 230 V AC
20 24 DC  3RF2320-1CA02 1 1 unit 41C
30  3RF2330-1CA02 1 1 unit 41C
20 110 ... 230 AC  3RF2320-1CA22 1 1 unit 41C

3RF2320-1
Low noise2),
zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 460 V AC
20 24 DC  3RF2320-1CA04 1 1 unit 41C
20 110 ... 230 AC  3RF2320-1CA24 1 1 unit 41C
20 4 ... 30 DC  3RF2320-1CA44 1 1 unit 41C
Short-circuit-proof with B MCB ·
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 24 ... 230 V AC
20 24 DC  3RF2320-1DA02 1 1 unit 41C
20 110 ... 230 AC  3RF2320-1DA22 1 1 unit 41C
Short-circuit-proof with B MCB ·
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 460 V AC
20 24 DC  3RF2320-1DA04 1 1 unit 41C
40 24 DC low power -- 3RF2340-1DA04-0KN0 1 1 unit 41C
20 110 ... 230 AC  3RF2320-1DA24 1 1 unit 41C
20 4 ... 30 DC  3RF2320-1DA44 1 1 unit 41C
30  3RF2330-1DA44 1 1 unit 41C
303) 24 DC  3RF2330-1DA06 1 1 unit 41C

3RF2330-1
 These versions are equipped with a special mounting foot. Snapping them 1) The type current provides information about the performance of the
onto grounded DIN rails or mounting them on a grounded mounting plate solid-state contactor. The actual permitted rated operational current Ie
simultaneously provides safe grounding of the heat sink. Additional can be smaller depending on the installation conditions.
grounding is no longer necessary in this case. For derating characteristic curves, see page 6/120, "More information".
-- With these versions, the ground connection to the heat sink can be 2) See page 6/135.
established by means of a screw terminal connection. 3) Blocking voltage 1 600 V, rated operational voltage Ue 48 ... 600 V AC
Other rated control supply voltages on request.
Accessories, see page 6/145.

* You can order this quantity or a multiple thereof.


6/140 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF23 solid-state contactors, 1-phase

Type current/ Operational Rated control Ground- Screw terminals PU PS* PG


performance current supply voltage Us ing (UNIT,
capacity1) Ie/AC-152) SET, M)
Imax
Article No. Price
A A V per PU
Instantaneous switching · Integrated heat sink,
rated operational voltage Ue 24 ... 230 V AC
10.5 6 24 DC  3RF2310-1BA02 1 1 unit 41C
20 12  3RF2320-1BA02 1 1 unit 41C
30 15  3RF2330-1BA02 1 1 unit 41C
40 20 -- 3RF2340-1BA02 1 1 unit 41C
50 25 -- 3RF2350-1BA02 1 1 unit 41C
50 27.5 -- 3RF2370-1BA02 1 1 unit 41C
10.5 6 110 ... 230 AC  3RF2310-1BA22 1 1 unit 41C
20 12  3RF2320-1BA22 1 1 unit 41C
30 15  3RF2330-1BA22 1 1 unit 41C
40 20 -- 3RF2340-1BA22 1 1 unit 41C
50 25 -- 3RF2350-1BA22 1 1 unit 41C
3RF2310-1 50 27.5 -- 3RF2370-1BA22 1 1 unit 41C
Instantaneous switching · Integrated heat sink,
rated operational voltage Ue 48 ... 460 V AC
10.5 6 24 DC  3RF2310-1BA04 1 1 unit 41C
20 12  3RF2320-1BA04 1 1 unit 41C
30 15  3RF2330-1BA04 1 1 unit 41C

6
40 20 -- 3RF2340-1BA04 1 1 unit 41C
50 25 -- 3RF2350-1BA04 1 1 unit 41C
50 27.5 -- 3RF2370-1BA04 1 1 unit 41C
10.5 6 110 ... 230 AC  3RF2310-1BA24 1 1 unit 41C
20 12  3RF2320-1BA24 1 1 unit 41C
30 15  3RF2330-1BA24 1 1 unit 41C
40 20 -- 3RF2340-1BA24 1 1 unit 41C
50 25 -- 3RF2350-1BA24 1 1 unit 41C
3RF2320-1 50 27.5 -- 3RF2370-1BA24 1 1 unit 41C
20 12 4 ... 30 DC  3RF2320-1BA44 1 1 unit 41C
30 15  3RF2330-1BA44 1 1 unit 41C
50 25 -- 3RF2350-1BA44 1 1 unit 41C
Instantaneous switching · Integrated heat sink,
blocking voltage 1 600 V,
rated operational voltage Ue 48 ... 600 V AC
10.5 6 24 DC  3RF2310-1BA06 1 1 unit 41C
20 12  3RF2320-1BA06 1 1 unit 41C
30 15  3RF2330-1BA06 1 1 unit 41C
40 20 -- 3RF2340-1BA06 1 1 unit 41C
50 25 -- 3RF2350-1BA06 1 1 unit 41C
50 27.5 -- 3RF2370-1BA06 1 1 unit 41C
10.5 6 110 ... 230 AC  3RF2310-1BA26 1 1 unit 41C
20 12  3RF2320-1BA26 1 1 unit 41C
30 15  3RF2330-1BA26 1 1 unit 41C
40 20 -- 3RF2340-1BA26 1 1 unit 41C
50 25 -- 3RF2350-1BA26 1 1 unit 41C
3RF2330-1 50 27.5 -- 3RF2370-1BA26 1 1 unit 41C
 These versions are equipped with a special mounting foot. Snapping them Other rated control supply voltages on request.
onto grounded DIN rails or mounting them on a grounded mounting plate
simultaneously provides safe grounding of the heat sink. Additional Accessories, see page 6/145.
grounding is no longer necessary in this case.
-- With these versions, the ground connection to the heat sink can be
established by means of a screw terminal connection.
1) The type current provides information about the performance of the
solid-state contactor. The actual permitted rated operational current Ie
can be smaller depending on the installation conditions.
For derating characteristic curves, see page 6/120, "More information".
2) Utilization category AC-15:
Electromagnetic loads, e.g. valves according to IEC 60947-5-1.
Parameters: max. 1 200 1/h, 50% ON period, 10-times inrush current
for 60 ms.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/141
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF23 solid-state contactors, 1-phase

Type current/ Rated control supply Grounding Spring-loaded PU PS* PG


performance voltage Us terminals (UNIT,
capacity1) SET, M)
Imax
Article No. Price
A V per PU
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 24 ... 230 V AC
10.5 24 DC  3RF2310-2AA02 1 1 unit 41C
20  3RF2320-2AA02 1 1 unit 41C
10.5 110 ... 230 AC  3RF2310-2AA22 1 1 unit 41C
20  3RF2320-2AA22 1 1 unit 41C

3RF2320-2
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 460 V AC
10.5 24 DC  3RF2310-2AA04 1 1 unit 41C
20  3RF2320-2AA04 1 1 unit 41C
10.5 110 ... 230 AC  3RF2310-2AA24 1 1 unit 41C
6

20  3RF2320-2AA24 1 1 unit 41C


Zero-point switching · Integrated heat sink,
blocking voltage 1 600 V,
rated operational voltage Ue 48 ... 600 V AC
10.5 24 DC  3RF2310-2AA06 1 1 unit 41C
20  3RF2320-2AA06 1 1 unit 41C
10.5 110 ... 230 AC  3RF2310-2AA26 1 1 unit 41C
20  3RF2320-2AA26 1 1 unit 41C
2)
Low noise ,
zero-point switching · Integrated heat sink,
rated operational voltage Ue 24 ... 230 V AC
20 24 DC  3RF2320-2CA02 1 1 unit 41C
20 110 ... 230 AC  3RF2320-2CA22 1 1 unit 41C
Low noise2),
zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 460 V AC
20 24 DC  3RF2320-2CA04 1 1 unit 41C
20 110 ... 230 AC  3RF2320-2CA24 1 1 unit 41C
Short-circuit-proof with B MCB,
zero-point switching · Integrated heat sink,
rated operational voltage Ue 24 ... 230 V AC
20 110 ... 230 AC  3RF2320-2DA22 1 1 unit 41C

Short-circuit-proof with B MCB,


zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 460 V AC
20 24 DC  3RF2320-2DA04 1 1 unit 41C
30  3RF2330-2DA64 1 1 unit 41C
20 110 ... 230 AC  3RF2320-2DA24 1 1 unit 41C
 These versions are equipped with a special mounting foot. Snapping them Other rated control supply voltages on request.
onto grounded DIN rails or mounting them on a grounded mounting plate
simultaneously provides safe grounding of the heat sink. Additional Accessories, see page 6/145.
grounding is no longer necessary in this case.
1) The type current provides information about the performance of the
solid-state contactor. The actual permitted rated operational current Ie
can be smaller depending on the installation conditions.
For derating characteristic curves, see page 6/120, "More information".
2) See page 6/135.

* You can order this quantity or a multiple thereof.


6/142 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF23 solid-state contactors, 1-phase

Type current/ Rated control supply Grounding Ring cable lug PU PS* PG
performance voltage Us connection (UNIT,
capacity1) SET, M)
Imax
Article No. Price
A V per PU
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 24 ... 230 V AC
10.5 24 DC  3RF2310-3AA02 1 1 unit 41C
20  3RF2320-3AA02 1 1 unit 41C
30  3RF2330-3AA02 1 1 unit 41C
40 -- 3RF2340-3AA02 1 1 unit 41C
50 -- 3RF2350-3AA02 1 1 unit 41C
70 -- 3RF2370-3AA02 1 1 unit 41C
10.5 110 ... 230 AC  3RF2310-3AA22 1 1 unit 41C
20  3RF2320-3AA22 1 1 unit 41C
30  3RF2330-3AA22 1 1 unit 41C
40 -- 3RF2340-3AA22 1 1 unit 41C
50 -- 3RF2350-3AA22 1 1 unit 41C
3RF2310-3 70 -- 3RF2370-3AA22 1 1 unit 41C
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 460 V AC
10.5 24 DC  3RF2310-3AA04 1 1 unit 41C
20  3RF2320-3AA04 1 1 unit 41C
30  3RF2330-3AA04 1 1 unit 41C

6
40 -- 3RF2340-3AA04 1 1 unit 41C
50 -- 3RF2350-3AA04 1 1 unit 41C
70 -- 3RF2370-3AA04 1 1 unit 41C
10.5 110 ... 230 AC  3RF2310-3AA24 1 1 unit 41C
20  3RF2320-3AA24 1 1 unit 41C
30  3RF2330-3AA24 1 1 unit 41C
40 -- 3RF2340-3AA24 1 1 unit 41C
50 -- 3RF2350-3AA24 1 1 unit 41C
3RF2330-3 70 -- 3RF2370-3AA24 1 1 unit 41C
20 4 ... 30 DC  3RF2320-3AA44 1 1 unit 41C
30  3RF2330-3AA44 1 1 unit 41C
50 -- 3RF2350-3AA44 1 1 unit 41C
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 600 V AC
40 4 ... 30 DC -- 3RF2340-3AA45 1 1 unit 41C
70 -- 3RF2370-3AA45 1 1 unit 41C
Zero-point switching · Integrated heat sink,
blocking voltage 1 600 V,
rated operational voltage Ue 48 ... 600 V AC
10.5 24 DC  3RF2310-3AA06 1 1 unit 41C
20  3RF2320-3AA06 1 1 unit 41C
30  3RF2330-3AA06 1 1 unit 41C
40 -- 3RF2340-3AA06 1 1 unit 41C
50 -- 3RF2350-3AA06 1 1 unit 41C
70 -- 3RF2370-3AA06 1 1 unit 41C
10.5 110 ... 230 AC  3RF2310-3AA26 1 1 unit 41C
20  3RF2320-3AA26 1 1 unit 41C
30  3RF2330-3AA26 1 1 unit 41C
40 -- 3RF2340-3AA26 1 1 unit 41C
50 -- 3RF2350-3AA26 1 1 unit 41C
70 -- 3RF2370-3AA26 1 1 unit 41C
 These versions are equipped with a special mounting foot. Snapping them Other rated control supply voltages on request.
onto grounded DIN rails or mounting them on a grounded mounting plate
simultaneously provides safe grounding of the heat sink. Additional Accessories, see page 6/145.
grounding is no longer necessary in this case.
-- With these versions, the ground connection to the heat sink can be
established by means of a screw terminal connection.
1)
The type current provides information about the performance of the
solid-state contactor. The actual permitted rated operational current Ie
can be smaller depending on the installation conditions.
For derating characteristic curves, see page 6/120, "More information".

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/143
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF23 solid-state contactors, 1-phase

Type current/ Operational Rated control supply Ground- Ring cable lug PU PS* PG
performance current voltage Us ing connection (UNIT,
capacity1) Ie/AC-152) SET, M)
Imax
Article No. Price
A A V per PU
Instantaneous switching · Integrated heat sink,
rated operational voltage Ue 24 ... 230 V AC
70 27.5 24 DC -- 3RF2370-3BA02 1 1 unit 41C
70 27.5 110 ... 230 AC -- 3RF2370-3BA22 1 1 unit 41C
Instantaneous switching · Integrated heat sink,
rated operational voltage Ue 48 ... 460 V AC
70 27.5 24 DC -- 3RF2370-3BA04 1 1 unit 41C
70 27.5 110 ... 230 AC -- 3RF2370-3BA24 1 1 unit 41C
Instantaneous switching · Integrated heat sink,
blocking voltage 1 600 V,
rated operational voltage Ue 48 ... 600 V AC
70 27.5 24 DC -- 3RF2370-3BA06 1 1 unit 41C
70 27.5 110 ... 230 AC -- 3RF2370-3BA26 1 1 unit 41C
Short-circuit-proof with B MCB,
zero-point switching · Integrated heat sink,
rated operational voltage Ue 24 ... 230 V AC
6

20 -- 24 DC  3RF2320-3DA02 1 1 unit 41C


20 -- 110 ... 230 AC  3RF2320-3DA22 1 1 unit 41C

3RF2320-3DA02
Short-circuit-proof with B MCB,
zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 460 V AC
20 -- 24 DC  3RF2320-3DA04 1 1 unit 41C
20 -- 110 ... 230 AC  3RF2320-3DA24 1 1 unit 41C
 These versions are equipped with a special mounting foot. Snapping them Other rated control supply voltages on request.
onto grounded DIN rails or mounting them on a grounded mounting plate
simultaneously provides safe grounding of the heat sink. Additional Accessories, see page 6/145.
grounding is no longer necessary in this case.
-- With these versions, the ground connection to the heat sink can be
established by means of a screw terminal connection.
1)
The type current provides information about the performance of the
solid-state contactor. The actual permitted rated operational current Ie
can be smaller depending on the installation conditions.
For derating characteristic curves, see page 6/120, "More information".
2)
Utilization category AC-15:
Electromagnetic loads, e.g. valves according to IEC 60947-5-1.
Parameters: max. 1 200 1/h, 50% ON period, 10-times inrush current
for 60 ms.

* You can order this quantity or a multiple thereof.


6/144 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF23 solid-state contactors, 1-phase

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Terminal covers
Ring cable lug
connection
Terminal covers 3RF2900-3PA88 1 10 units 41C
For 3RF23 solid-state contactors with ring cable lug
connection
With this terminal cover, degree of protection IP20
can be achieved on the front with a ring cable lug
connection. It can also be used for screw terminals
after simple adaptation.

3RF2900-3PA88
Control connectors
Screw terminals

Replacement control connectors 3RF2900-1TA88 1 50 units 41C


For 3RF23 and 3RF24 solid-state contactors
With screw terminals

6
3RF2900-1TA88
Spring-loaded
terminals
Replacement control connectors 3RF2900-2TA88 1 50 units 41C
For 3RF23 and 3RF24 solid-state contactors
With spring-loaded terminals

3RF2900-2TA88
Control connectors 3RF2900-2TB88 1 10 units 41C
For 3RF23 and 3RF24 solid-state contactors
With spring-loaded terminals
With two clamping points per contact

3RF2900-2TB88
Tools for opening spring-loaded terminals
Screwdrivers 3RA2908-1A 1 1 unit 41B
For all SIRIUS devices
With spring-loaded terminals
Length approx. 200 mm,
size 3.0 mm x 0.5 mm,
3RA2908-1A titanium gray/black,
partially insulated
Blank labels
Unit labeling plates
For SIRIUS devices1)
10 mm × 7 mm, titanium gray 3RT2900-1SB10 100 816 41B
units
20 mm × 7 mm, titanium gray 3RT2900-1SB20 100 340 41B
IC01_00181

units
Adhesive labels
3RT2900-1SB20 For SIRIUS devices
19 mm × 6 mm, titanium gray 3RT2900-1SB60 100 3060 41B
units
1) PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/145
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF24 solid-state contactors, 3-phase

■ Technical specifications
More information
System Manual for modular system, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16223/faq
https://support.industry.siemens.com/cs/ww/en/view/60311318

Type 3RF24..-1.... 3RF24..-2.... 3RF24..-3....


Dimensions (W x H x D) See page 6/147
General data
Ambient temperature
• During operation, derating from 40 °C °C -25 ... +60
• During storage °C -55 ... +80
Installation altitude m 0 ... 1 000; derating from 1 000
Shock resistance according to IEC 60068-2-27 g/ms 15/11
Vibration resistance according to IEC 60068-2-6 g 2
Degree of protection IP on the front IP20 IP00
according to IEC 60529
Touch protection on the front Finger-safe for vertical touching from the front --
according to IEC 60529
Insulation strength at 50/60 Hz V rms 4 000
(main/control circuit to floor)
6

Electromagnetic compatibility (EMC)


• Emitted interference according to IEC 60947-4-3
- Conducted interference voltage Class A for industrial applications1)
• Interference immunity
- Electrostatic discharge kV Contact discharge 4; air discharge 8; behavior criterion 2
according to IEC 61000-4-2
(corresponds to degree of severity 3)
- Induced RF fields according to IEC 61000-4-6 MHz 0.15 ... 80; 140 dBµV; behavior criterion 1
- Burst according to IEC 61000-4-4 kV 2/5.0 kHz; behavior criterion 2
- Surge according to IEC 61000-4-5 kV Conductor - ground 2; conductor - conductor 1; behavior criterion 2
Connection type Screw terminals Spring-loaded Ring cable lug
terminals connection
Connection, main contacts
• Conductor cross-section
- Solid mm2 2 x (1.5 ... 2.5)2), 2 x (2.5 ... 6)2) 2 x (0.5 ... 2.5) --
- Finely stranded with end sleeve mm2 2 x (1 ... 2.5)2), 2 x (2.5 ... 6)2), 2 x (0.5 ... 1.5) --
1 x 10
- Finely stranded without end sleeve mm2 -- 2 x (0.5 ... 2.5) --
- Solid or stranded, AWG cables AWG 2 x (14 ... 10) 2 x (18 ... 14) --
• Stripped length mm 10 10 --
• Terminal screws M4 -- M5
- Tightening torque Nm 2 ... 2.5 2 ... 2.5
lb.in 18 ... 22 18 ... 22
• Cable lugs
- According to DIN 46234 -- -- 5-2.5 ... 5-25
- According to JIS C 2805 -- -- R 2-5 ... R 14-5
- Width, maximum mm -- -- 12
Connection, auxiliary/control contacts
• Conductor cross-section mm 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.0) 0.5 ... 2.5 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.0)
AWG 20 ... 12 20 ... 12 20 ... 12
• Stripped length mm 7 10 7
• Terminal screw M3 -- M3
- Tightening torque, Nm 0.5 ... 0.6 -- 0.5 ... 0.6
 3.5 mm, PZ 1 lb.in 4.5 ... 5.3 -- 4.5 ... 5.3
Grounding studs Optional,
see also note on page 6/135 about the special mounting foot for safe grounding on DIN rails
for version 3RF2410
• Size (standard screw) M5
Permissible mounting position ±10° ±10°

NSB0_01703

1) These products were built as Class A devices. The use of these devices
in residential areas could result in radio interference. In this case it may
be required to introduce additional interference suppression measures.
The versions 3RF24..-1AC55 comply with Class B for residential, business
and commercial applications.
2)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in one of the ranges specified.

6/146 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF24 solid-state contactors, 3-phase

Type Type current/ Rated operational current Ie Power loss Minimum load Max. off-state Rated peak I2t value
performance at IAC-51 current current withstand
capacity1) current Itsm
IAC-51 according to according to
IEC 60947-4-3 UL/CSA
at 40 °C at 40 °C at 50 °C
A A A W A mA A A²s
Main circuit
3RF2410-.AB.5 10.5 7 7 23 0.1 10 200 200
3RF2420-.AB.5 22 15 15 44 0.5 10 600 1 800
3RF2430-.AB.5 30 22 22 61 0.5 10 1 200 7 200
3RF2440-.AB.5 40 30 30 80 0.5 10 1 150 6 600
3RF2450-.AB.5 50 38 38 107 0.5 10 1 150 6 600
3RF2410-.AC.5 10.5 7 7 31 0.5 10 300 450
3RF2420-.AC.5 22 15 15 66 0.5 10 600 1 800
3RF2430-.AC.5 30 22 22 91 0.5 10 1 200 7 200
3RF2440-.AC.5 40 30 30 121 0.5 10 1 150 6 600
3RF2450-.AC.5 50 38 38 160 0.5 10 1 150 6 600
1)
The type current provides information about the performance of the
solid-state contactor. The actual permitted rated operational current Ie
can be smaller depending on the connection method and installation
conditions.

Type Type current Dimensions (W x H x D) Type Type current Dimensions (W x H x D)


IAC-51 (including heat sink) IAC-51 (including heat sink)

6
H

H
D

D
W W

A mm A mm
Main circuit Main circuit
3RF2410-.AB.. 10.5 45 x 95 x 92.5 3RF2430-.AC.. 30 89.5 x 100 x 123
3RF2410-.AC.. 3RF2440-.AB.. 40
3RF2420-.AB.. 22 45 x 100 x 112 3RF2440-.AC.. 40 120 x 95 x 130
3RF2420-.AC.. 22 74.5 x 100 x 114.5 3RF2450-.AB.. 50
3RF2430-.AB.. 30 3RF2450-.AC.. 50 120 x 150 x 130

Type 3RF24..-.AB.5 3RF24..-.AC.5


Main circuit
Controlled phases 2-phase 3-phase
Rated operational voltage Ue V AC 48 ... 600
• Operating range V AC 40 ... 660
• Rated frequency Hz 50/60  10%
Rated insulation voltage Ui V 600
Rated impulse withstand voltage Uimp kV 6
Blocking voltage V 1 200
Rate of voltage rise V/µs 1 000

Type 3RF24..-...3. 3RF24..-...4. 3RF24..-...5.


Control circuit
Method of operation AC operation DC operation AC operation
Rated control supply voltage Us V 110 4 ... 30 190 ... 230
Rated frequency Hz 50/60  10% -- 50/60  10%
of the control supply voltage
Actuating voltage, max. V 121 30 253
Typical actuating current mA 15 30 15
Response voltage V 90 4 180
Drop-out voltage V < 40 <1 < 40
Operating times
• ON-delay ms 40 + max. one half-wave 1 + max. one half-wave 40 + max. one half-wave
• OFF-delay ms 40 + max. one half-wave 1 + max. one half-wave 40 + max. one half-wave

Siemens IC 10 · 2023 6/147


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF24 solid-state contactors, 3-phase

■ Selection and ordering data


Type current/ Rated control supply Grounding Screw terminals PU PS* PG
performance voltage Us (UNIT,
capacity1) SET, M)
Imax
Article No. Price
A V per PU
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 600 V AC
2-phase controlled
10.5 4 ... 30 DC  3RF2410-1AB45 1 1 unit 41C
20 -- 3RF2420-1AB45 1 1 unit 41C
30 -- 3RF2430-1AB45 1 1 unit 41C
40 -- 3RF2440-1AB45 1 1 unit 41C
50 -- 3RF2450-1AB45 1 1 unit 41C
10.5 110 AC  3RF2410-1AB35 1 1 unit 41C
20 -- 3RF2420-1AB35 1 1 unit 41C
3RF2410-1AB45 30 -- 3RF2430-1AB35 1 1 unit 41C
40 -- 3RF2440-1AB35 1 1 unit 41C
50 -- 3RF2450-1AB35 1 1 unit 41C
10.5 230 AC  3RF2410-1AB55 1 1 unit 41C
20 -- 3RF2420-1AB55 1 1 unit 41C
30 -- 3RF2430-1AB55 1 1 unit 41C
40 -- 3RF2440-1AB55 1 1 unit 41C
6

50 -- 3RF2450-1AB55 1 1 unit 41C


3-phase controlled
10.5 4 ... 30 DC  3RF2410-1AC45 1 1 unit 41C
20 -- 3RF2420-1AC45 1 1 unit 41C
30 -- 3RF2430-1AC45 1 1 unit 41C
40 -- 3RF2440-1AC45 1 1 unit 41C
50 -- 3RF2450-1AC45 1 1 unit 41C
10.5 110 AC  3RF2410-1AC35 1 1 unit 41C
20 -- 3RF2420-1AC35 1 1 unit 41C
3RF2410-1AC45 30 -- 3RF2430-1AC35 1 1 unit 41C
40 -- 3RF2440-1AC35 1 1 unit 41C
50 -- 3RF2450-1AC35 1 1 unit 41C
10.5 230 AC  3RF2410-1AC55 1 1 unit 41C
20 -- 3RF2420-1AC55 1 1 unit 41C
30 -- 3RF2430-1AC55 1 1 unit 41C
40 -- 3RF2440-1AC55 1 1 unit 41C
50 -- 3RF2450-1AC55 1 1 unit 41C
 These versions are equipped with a special mounting foot. Snapping them Accessories, see page 6/145.
onto grounded DIN rails or mounting them on a grounded mounting plate
simultaneously provides safe grounding of the heat sink. Additional
grounding is no longer necessary in this case.
-- With these versions, the ground connection to the heat sink can be
established by means of a screw terminal connection.
1)
The type current provides information about the performance of the
solid-state contactor. The actual permitted rated operational current Ie
can be smaller depending on the connection method and installation
conditions.
For derating characteristic curves, see page 6/120, "More information".

* You can order this quantity or a multiple thereof.


6/148 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF2 solid-state relays and solid-state contactors
Solid-state contactors > SIRIUS 3RF24 solid-state contactors, 3-phase

Type current/ Rated control supply Grounding Spring-loaded PU PS* PG


performance voltage Us terminals (UNIT,
capacity1) SET, M)
Imax
Article No. Price
A V per PU
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 600 V AC
2-phase controlled
10 4 ... 30 DC  3RF2410-2AB45 1 1 unit 41C
20 -- 3RF2420-2AB45 1 1 unit 41C
10 230 AC  3RF2410-2AB55 1 1 unit 41C
20 -- 3RF2420-2AB55 1 1 unit 41C
3-phase controlled
10 4 ... 30 DC  3RF2410-2AC45 1 1 unit 41C
20 -- 3RF2420-2AC45 1 1 unit 41C
10 230 AC  3RF2410-2AC55 1 1 unit 41C
3RF2410-2AB45 20 -- 3RF2420-2AC55 1 1 unit 41C
1)
 These versions are equipped with a special mounting foot. Snapping them The type current provides information about the performance of the
onto grounded DIN rails or mounting them on a grounded mounting plate solid-state contactor. The actual permitted rated operational current Ie
simultaneously provides safe grounding of the heat sink. Additional can be smaller depending on the connection method and installation
grounding is no longer necessary in this case. conditions.
-- With these versions, the ground connection to the heat sink can be For derating characteristic curves, see page 6/120, "More information".

6
established by means of a screw terminal connection.

Type current/ Rated control supply Grounding Ring cable lug PU PS* PG
performance voltage Us connection (UNIT,
capacity1) SET, M)
Imax
Article No. Price
A V per PU
Zero-point switching · Integrated heat sink,
rated operational voltage Ue 48 ... 600 V AC
2-phase controlled
50 4 ... 30 DC -- 3RF2450-3AB45 1 1 unit 41C
50 230 AC -- 3RF2450-3AB55 1 1 unit 41C
3-phase controlled
50 4 ... 30 DC -- 3RF2450-3AC45 1 1 unit 41C
50 230 AC -- 3RF2450-3AC55 1 1 unit 41C

-- With these versions, the ground connection to the heat sink can be Accessories, see page 6/145.
established by means of a screw terminal connection.
1)
The type current provides information about the performance of the
solid-state contactor. The actual permitted rated operational current Ie
can be smaller depending on the connection method and installation
conditions.
For derating characteristic curves, see page 6/120, "More information".

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/149
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF29 function modules
General data

■ Overview
Function modules for SIRIUS 3RF2 solid-state switching devices
A great variety of applications demand an expanded range The following function modules are available:
of functionality. With our function modules, these requirements • Converters (without current measurement)
can be met really easily. The modules are mounted simply • Load monitoring
by clicking them into place; straight away the necessary • Heating current monitoring
connections are made with the solid-state relay or contactor. • Power controllers
The plug-in connection to control the solid-state switching • Power regulators
devices can simply remain in use. The external connections Note:
have screw terminals.
With the exception of the converter, the function modules can
For function modules with current measurement, the load cable be used only with 1-phase solid-state switching devices.
must be inserted through the straight-through transformer and
reconnected to the solid-state switching device. For recommended assignment of the function modules to
3RF2 solid-state switching devices, see Industry Mall.

■ Technical specifications
More information
Online configurator, see www.siemens.com/sirius/configurators FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16231/faq
System Manual for modular system, see Conversion tool, see www.siemens.com/conversion-tool
6

https://support.industry.siemens.com/cs/ww/en/view/60311318

Type 3RF29..-0EA.. 3RF29..-0FA.. 3RF29..-0GA.. 3RF29..-0HA.. 3RF29..-0JA.. 3RF29..-0KA..


Dimensions (W x H x D) mm 22.5 x 84 x 38 22.5 x 102 x 39 45 x 112 x 44 45 x 112 x 44 45 x 112 x 44 45 x 112 x 44
General data
Ambient temperature
• During operation, derating from 40 °C °C -25 ... +60
• During storage °C -55 ... +80
Installation altitude m 0 ... 1 000; derating from 1 000
Shock resistance according to IEC 60068-2-27 g/ms 15/11
Vibration resistance according to IEC 60068-2-6 g 2
Degree of protection IP on the front IP20
according to IEC 60529
Touch protection on the front Finger-safe for vertical touching from the front
according to IEC 60529
Electromagnetic compatibility (EMC)
• Emitted interference
- Conducted interference voltage Class A for industrial applications1)
according to IEC 60947-4-3
- Emitted, high-frequency interference voltage Class B for residential, business and commercial applications
according to IEC 60947-4-3
• Interference immunity
- Electrostatic discharge kV Contact discharge 4; air discharge 8; behavior criterion 2
according to IEC 61000-4-2
(corresponds to degree of severity 3)
- Induced RF fields according to IEC 61000-4-6 MHz 0.15 ... 80; 140 dBV; behavior criterion 1
- Burst according to IEC 61000-4-4 2 kV/5.0 kHz; behavior criterion 2
- Surge according to IEC 61000-4-5 kV Conductor - ground 2; conductor - conductor 1; behavior criterion 2
Connection type Screw terminals
Auxiliary/control contacts
• Conductor cross-section mm2 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.0), 1 x (AWG 20 ... 12)
• Stripped length mm 7
• Terminal screw M3
• Tightening torque Nm 0.5 ... 0.6
lb.in 4.5 ... 5.3
Connection type Straight-through transformers
Converters
• Diameter mm -- 7 17
1)
Note limitations for power controller and power regulator function modules.
These modules were built as Class A devices. The use of these devices in
residential areas could result in radio interference. In this case it may be
required to introduce additional interference suppression measures.

6/150 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF29 function modules
General data

Type 3RF29..-0EA181) 3RF29..-0FA081) 3RF29..-0GA.3 3RF29..-0GA.6


Main circuit
Rated operational voltage Ue V AC -- 110 ... 230 400 ... 600
• Operating range V AC -- 93.5 ... 253 340 ... 660
• Rated frequency Hz -- 50/60
Rated insulation voltage Ui V -- 600
Voltage measuring
• Measuring range V -- 93.5 ... 253 340 ... 660
Mains voltage, fluctuation % -- 20
compensation
1) Versions are independent of the main circuit.

Type 3RF29..-0HA.3 3RF29..-0HA.6 3RF29..-0JA.3 3RF29..-0JA.6


3RF29..-0KA.3 3RF29..-0KA.6
Main circuit
Rated operational voltage Ue V AC 110 ... 230 400 ... 600 110 ... 230 400 ... 600
• Operating range V AC 93.5 ... 253 340 ... 660 93.5 ... 253 340 ... 660
• Rated frequency Hz 50/60
Rated insulation voltage Ui V 600
Voltage measuring
• Measuring range V 93.5 ... 253 340 ... 660 93.5 ... 253 340 ... 660
Mains voltage, fluctuation % 20
compensation

6
Type 3RF29..-...0. 3RF29..-...1.
Control circuit
Method of operation DC operation AC/DC operation
Rated control supply voltage Us V 24
Rated actuating current mA 25 40
Rated frequency Hz -- 50/60
of the control supply voltage
Actuating voltage, max. V 30
Rated actuating current mA 30 50
At maximum voltage
Response voltage V 15
• For operating current mA 2
Drop-out voltage V 5

Type 3RF2906-0FA08 3RF2920-0FA08 3RF2920-0GA.. 3RF2950-0GA.. 3RF2990-0GA..


Current measurement
Rated operational current Ie A 6 20 50 90
Current measurement
• Teach range A 0.25 … 6 0.65 … 20 0.56 … 20 1.62 … 50 2.93 … 90
• Measuring range A 0 … 6.6 0 … 22 0 … 55 0 … 99
• Minimum partial load current A 0.25 0.65 1.6 2.9
Number of partial loads 1…6 1 … 12

Type 3RF2920-0HA.. 3RF2950-0HA.. 3RF2990-0HA.. 3RF2916-0JA.. 3RF2932-0JA..


Current measurement
Rated operational current Ie A 20 50 90 16 32
Current measurement
• Teach range A 4 ... 20 10 ... 50 18 ... 90 0.42 ... 16 0.8 ... 32
• Measuring range A 0 ... 22 0 ... 55 4 ... 99 0 ... 16 0 ... 32
• Minimum partial load current A -- 0.42 0.8
Number of partial loads -- 1 ... 6

Type 3RF2904-0KA.. 3RF2920-0KA.. 3RF2950-0KA.. 3RF2990-0KA..


Current measurement
Rated operational current Ie A 4 20 50 90
Current measurement
• Teach range A 0.15 ... 4 0.65 ... 20 1.6 ... 50 2.9 ... 90
• Measuring range A 0 ... 4 0 ... 22 0 ... 55 0 ... 99
• Minimum partial load current A -- 0.65 1.6 2.9
Number of partial loads -- 1 ... 6

Siemens IC 10 · 2023 6/151


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF29 function modules
SIRIUS converters for 3RF2

■ Overview ■ Application
Converters for 3RF2 solid-state switching devices The function module is used for converting an analog input
signal to an input/output ratio with the time base 1 s. The module
These modules are used to convert analog control signals, such can only be used in conjunction with 3RF21 and 3RF23 1-phase
as those output from many temperature controllers for example, solid-state switching devices or 3RF22 and 3RF24 3-phase
into a pulse-width-modulated digital signal. The connected devices. It can be used on versions with 24 V DC and
solid-state contactors and relays can therefore regulate the 24 V AC/DC control supply voltage.
output of a load as a percentage.
Note:
The use of 1-pole solid-state switching devices with converters,
power controllers or power regulators of loads in a three-phase
network in full-wave control mode is not recommended.
As mutual synchronization of the function modules is not
possible, fluctuations in the heating power are possible; there is
no optimum settling in particular with setpoint values < 50%.

■ Selection and ordering data


Rated operational current Ie Rated operational voltage Ue Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price
A V per PU
6

Converters
Rated control supply voltage 24 V AC/DC
-- -- 3RF2900-0EA18 1 1 unit 41C

3RF2900-0EA18

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Blank labels
Unit labeling plates
For SIRIUS devices1)
10 mm × 7 mm, titanium gray 3RT2900-1SB10 100 816 41B
units
20 mm × 7 mm, titanium gray 3RT2900-1SB20 100 340 41B
IC01_00181

units
Adhesive labels
3RT2900-1SB20 For SIRIUS devices
19 mm × 6 mm, titanium gray 3RT2900-1SB60 100 3060 41B
units
1) PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


6/152 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF29 function modules
SIRIUS load monitoring for 3RF2

■ Overview In order to detect the failure of one of several loads, the current
difference must be 1/6 (in the basic version) or 1/12 (in the
Load monitoring for 3RF2 1-phase solid-state switching extended version) of the reference value. In the event of a fault,
devices an output is actuated and one or more LEDs indicate the fault.

Many faults can be quickly detected by monitoring a load circuit


connected to the solid-state switching device, as made possible
■ Application
with this module. Examples include the failure of load elements The device is used for monitoring one or more loads
(up to 6 in the basic version or up to 12 in the extended version), (partial loads).
alloyed power semiconductors, a lack of voltage or a break in
a load circuit. A fault is indicated by one or more LEDs and Notes:
reported to the controller by way of a PLC-compatible output. The function module can only be used in conjunction with
The principle of operation is based on permanent monitoring of a 3RF21 solid-state relay or a 3RF23 solid-state contactor.
the current intensity. This figure is continuously compared with The solid-state switching devices with spring-loaded terminals
the reference value stored once during startup by the simple in the load circuit are not suitable for load monitoring!
press of a button.

■ Selection and ordering data


Rated operational current Ie Rated operational voltage Ue Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price

6
A V per PU
Basic load monitoring
Rated control supply voltage 24 V DC
6 -- 3RF2906-0FA08 1 1 unit 41C
20 -- 3RF2920-0FA08 1 1 unit 41C
• With mounted 3RF2900-0RA88 cover
6 -- 3RF2906-0FA08-0KH0 1 1 unit 41C
20 -- 3RF2920-0FA08-0KH0 1 1 unit 41C

3RF2920-0FA08
Extended load monitoring
Rated control supply voltage 24 V AC/DC
20 110 ... 230 3RF2920-0GA13 1 1 unit 41C
20 400 … 600 3RF2920-0GA16 1 1 unit 41C
50 110 ... 230 3RF2950-0GA13 1 1 unit 41C
50 400 … 600 3RF2950-0GA16 1 1 unit 41C
90 110 ... 230 3RF2990-0GA13 1 1 unit 41C
90 400 … 600 3RF2990-0GA16 1 1 unit 41C

3RF2920-0GA13

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Covers
Sealable covers for function modules 3RF2900-0RA88 1 10 units 41C
(not for converters)
For securing against unauthorized adjustment of setting knobs

3RF2900-0RA88
Blank labels
Unit labeling plates
For SIRIUS devices1)
10 mm × 7 mm, titanium gray 3RT2900-1SB10 100 816 41B
units
IC01_00181

20 mm × 7 mm, titanium gray 3RT2900-1SB20 100 340 41B


units
Adhesive labels
3RT2900-1SB20 For SIRIUS devices
19 mm × 6 mm, titanium gray 3RT2900-1SB60 100 3060 41B
units
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/153
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF29 function modules
SIRIUS heating current monitoring for 3RF2

■ Overview Special version with "Standby" mode:


Deviations from the standard version
Heating current monitoring for 3RF2 1-phase solid-state 3RF29..-0JA1.-1KK0
switching devices
If the current is below 50% of the lower teach current during
Many faults can be quickly detected by monitoring a load circuit the teach routine, the device will go into "Standby" mode;
connected to the solid-state switching device, as made possible the LOAD LED will flicker. The device thus detects
with this module. Examples include the failure of up to six load a non-connected load, e.g. channels not required for tool
elements, alloyed power semiconductors, a lack of voltage, heaters, and does not signal a fault. This mode can be reset
or a break in the load circuit. A fault is indicated by LEDs and by re-teaching.
reported to the controller via relay output (NC).
The principle of operation is based on permanent monitoring of ■ Application
the current intensity. This figure is continuously compared with
the reference value stored once during startup. In order to detect The device is used for monitoring one or more loads
the failure of one of several loads, the current difference must be (partial loads).
1/6 of the reference value. In the event of a fault, an output is Notes:
actuated and the LEDs indicate the fault.
The function module can only be used in conjunction with
The heating current monitoring has a teach input and therefore a 3RF21 solid-state relay or a 3RF23 solid-state contactor.
differs from the load monitoring. This remote teaching function
enables simple adjustment to changing loads without manual The solid-state switching devices with spring-loaded terminals
intervention. in the load circuit are not suitable!

■ Selection and ordering data


6

Rated operational current Ie Rated operational voltage Ue Screw terminals PU PS* PG


(UNIT,
SET, M)
Article No. Price
A V per PU
Heating current monitoring1)
Rated control supply voltage 24 V AC/DC
16 110 ... 230 3RF2916-0JA13 1 1 unit 41C
16 (with "Standby" mode) 110 ... 230 3RF2916-0JA13-1KK0 1 1 unit 41C
16 (with "Standby" mode) 400 … 600 3RF2916-0JA16-1KK0 1 1 unit 41C
32 (with "Standby" mode) 110 ... 230 3RF2932-0JA13-1KK0 1 1 unit 41C
32 400 … 600 3RF2932-0JA16 1 1 unit 41C
32 (with "Standby" mode) 400 … 600 3RF2932-0JA16-1KK0 1 1 unit 41C

3RF2916-0JA13
1)
Supplied without control connector. The control connector can be
purchased from Wieland by quoting article number 8213 B/6VR
(PCB connector), see page 16/18.

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Covers
Sealable covers for function modules 3RF2900-0RA88 1 10 units 41C
(not for converters)
For securing against unauthorized adjustment of setting knobs

3RF2900-0RA88
Blank labels
Unit labeling plates
For SIRIUS devices1)
10 mm × 7 mm, titanium gray 3RT2900-1SB10 100 816 41B
units
20 mm × 7 mm, titanium gray 3RT2900-1SB20 100 340 41B
IC01_00181

units
Adhesive labels
3RT2900-1SB20 For SIRIUS devices
19 mm × 6 mm, titanium gray 3RT2900-1SB60 100 3060 41B
units
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


6/154 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF29 function modules
SIRIUS power controllers for 3RF2

■ Overview ■ Application
Power controllers for 3RF2 1-phase solid-state switching The power controller can be used for:
devices • Complex heating systems
The power controller is a function module for the autonomous • Inductive loads
power control of complex heating systems and inductive loads. • Loads with temperature-dependent resistor
The following functions have been integrated: • Loads with ageing after long-time service
• Power controller • Simple indirect control of temperature
For adjusting the power of the connected load. The setpoint
value is selected via a rotary knob on the module as Notes:
a percentage of the 100% power value stored. This function module can only be used in conjunction with
• Inrush current limiting a 3RF21 solid-state relay or a 3RF23 solid-state contactor.
With the aid of an adjustable voltage ramp, the inrush current The solid-state switching devices with spring-loaded terminals
is limited by means of phase control. This is useful above all in the load circuit are not suitable!
with loads such as lamps or infrared lamps which have an
inrush transient current. Power control
• Load circuit monitoring The power controller adjusts the power in the connected load
For detecting load failure, partial load faults, alloyed power by means of a solid-state switching device depending on the
semiconductors, lack of voltage or a break in the load circuit. setpoint selection. It does not compensate for changes in the
Note: mains voltage or load resistance. The setpoint value can be
predefined externally as a 0 to 10 V signal or internally by
With the phase control operating mode, a partial load fault is

6
means of a potentiometer. Depending on the setting of the
detected by cyclic "scanning" of the load; the exact mode of potentiometer (tR), the control is carried out according to the
operation is described in the data sheets! principle of full-wave control or generalized phase control.
Special versions: Note:
Deviations from the standard version
In the case of ohmic loads, the power is set linear to the setpoint
3RF2904-0KA13-0KC0 (no teach current) value. During operation of inductive loads, the power control is
During the teach routine, the connected solid-state relay or no longer proportional and linear due to the phase shift between
contactor is not activated; i.e. no current will flow. No current current and voltage.
reference value is stored. No partial load monitoring! Full-wave control
3RF29..-0KA1.-0KT0 (without partial load faults) In this operating mode the output is adjusted to the required
No partial load monitoring! setpoint value by changing the on-to-off period. The period
duration is predefined at 1 s.
Notes:
The use of 1-pole solid-state switching devices with converters,
power controllers or power regulators of loads in a three-phase
network in full-wave control mode is not recommended.
As mutual synchronization of the function modules is not
possible, fluctuations in the heating power are possible; there is
no optimum settling in particular with setpoint values < 50%.
Generalized phase control
In this operating mode the output is adjusted to the required
setpoint value by changing the current flow angle. In order to
observe the limit values of the conducted interference voltage
for industrial networks, at loads up to 20 kVA, the load circuit
must include an additional filter, and for loads above 20 kVA,
a reactor with a rating of at least 200 H must be used. You will
find details about the filters in the FAQ "Filters for 3RF29 power
regulators and power controllers to comply with the limits for
electromagnetic emitted interference", see
https://support.industry.siemens.com/cs/ww/en/view/109751887.

Siemens IC 10 · 2023 6/155


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF29 function modules
SIRIUS power controllers for 3RF2

■ Selection and ordering data


Rated operational current Ie Rated operational voltage Ue Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price
A V per PU
Power controllers
Rated control supply voltage 24 V AC/DC
4 (no teach current) 110 ... 230 3RF2904-0KA13-0KC0 1 1 unit 41C
4 (without partial load faults) 3RF2904-0KA13-0KT0 1 1 unit 41C
20 3RF2920-0KA13 1 1 unit 41C
50 3RF2950-0KA13 1 1 unit 41C
90 3RF2990-0KA13 1 1 unit 41C
20 400 … 600 3RF2920-0KA16 1 1 unit 41C
50 3RF2950-0KA16 1 1 unit 41C
50 (without partial load faults) 3RF2950-0KA16-0KT0 1 1 unit 41C
3RF2904-0KA13 90 3RF2990-0KA16 1 1 unit 41C

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
6

SET, M)

Covers
Sealable covers for function modules 3RF2900-0RA88 1 10 units 41C
(not for converters)
For securing against unauthorized adjustment of setting knobs

3RF2900-0RA88
Blank labels
Unit labeling plates
For SIRIUS devices1)
10 mm × 7 mm, titanium gray 3RT2900-1SB10 100 816 41B
units
20 mm × 7 mm, titanium gray 3RT2900-1SB20 100 340 41B
IC01_00181

units
Adhesive labels
3RT2900-1SB20 For SIRIUS devices
19 mm × 6 mm, titanium gray 3RT2900-1SB60 100 3060 41B
units
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


6/156 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF29 function modules
SIRIUS power regulators for 3RF2

■ Overview ■ Application
Power regulators for 3RF2 1-phase solid-state switching The power regulator can be used for:
devices • Complex heating systems
The power regulator is a function module for the autonomous • Heating elements with temperature-dependent resistor
power control of complex heating systems. • Heating elements with ageing after long-time service
The following functions have been integrated: • Simple indirect control of temperature
• Power controller with proportional-action control Notes:
For adjusting the power of the connected load. The setpoint
value is selected via a rotary knob on the module as This function module can only be used in conjunction with
a percentage of the 100% power value stored. Changes in the a 3RF21 solid-state relay or a 3RF23 solid-state contactor.
mains voltage or in the load resistance are compensated in The solid-state switching devices with spring-loaded terminals
this case. in the load circuit are not suitable!
• Inrush current limiting
With the aid of an adjustable voltage ramp, the inrush current Power control
is limited by means of phase control. This is useful above all The power regulator adjusts the power in the connected load by
with loads such as lamps which have an inrush transient means of a solid-state switching device depending on the taught
current. power and the selected setpoint. Changes in the mains voltage
• Load circuit monitoring or in the load resistance are thus compensated by the power
For detecting load failure, alloyed power semiconductors, regulator. The setpoint value can be predefined externally as
lack of voltage or a break in the load circuit. Partial load a 0 to 10 V signal or internally by means of a potentiometer.
monitoring is not possible. Load fluctuations are compensated. Depending on the setting of the potentiometer (tR),

6
the adjustment is carried out according to the principle
of full-wave control or generalized phase control.
Note:
In the case of ohmic loads, the power is set linear to the setpoint
value. During operation of inductive loads, the power control is
no longer proportional and linear due to the phase shift between
current and voltage.
Full-wave control
In this operating mode the output is adjusted to the required
setpoint value by changing the on-to-off period. The period
duration is predefined at 1 s.
Notes:
The use of 1-pole solid-state switching devices with converters,
power controllers or power regulators of loads in a three-phase
network in full-wave control mode is not recommended.
As mutual synchronization of the function modules is not
possible, fluctuations in the heating power are possible; there is
no optimum settling in particular with setpoint values < 50%.
Generalized phase control
In this operating mode the output is adjusted to the required
setpoint value by changing the current flow angle. In order to
observe the limit values of the conducted interference voltage
for industrial networks, at loads up to 20 kVA, the load circuit
must include an additional filter, and for loads above 20 kVA,
a reactor with a rating of at least 200 H must be used. You will
find details about the filters in the FAQ "Filters for 3RF29 power
regulators and power controllers to comply with the limits for
electromagnetic emitted interference", see
https://support.industry.siemens.com/cs/ww/en/view/109751887.

Siemens IC 10 · 2023 6/157


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


Solid-state switching devices for resistive/inductive loads
SIRIUS 3RF29 function modules
SIRIUS power regulators for 3RF2

■ Selection and ordering data


Rated operational current Ie Rated operational voltage Ue Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price
A V per PU
Power regulators
Rated control supply voltage 24 V AC/DC
20 110 ... 230 3RF2920-0HA13 1 1 unit 41C
20 400 … 600 3RF2920-0HA16 1 1 unit 41C
50 110 ... 230 3RF2950-0HA13 1 1 unit 41C
50 400 … 600 3RF2950-0HA16 1 1 unit 41C
90 110 ... 230 3RF2990-0HA13 1 1 unit 41C
90 400 … 600 3RF2990-0HA16 1 1 unit 41C

3RF2920-0HA13

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
6

SET, M)

Covers
Sealable covers for function modules 3RF2900-0RA88 1 10 units 41C
(not for converters)
For securing against unauthorized adjustment of setting knobs

3RF2900-0RA88
Blank labels
Unit labeling plates
For SIRIUS devices1)
10 mm × 7 mm, titanium gray 3RT2900-1SB10 100 816 41B
units
20 mm × 7 mm, titanium gray 3RT2900-1SB20 100 340 41B
IC01_00181

units
Adhesive labels
3RT2900-1SB20 For SIRIUS devices
19 mm × 6 mm, titanium gray 3RT2900-1SB60 100 3060 41B
units
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


6/158 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RF34 solid-state switching devices for switching motors
Solid-state contactors
General data

■ Overview
More information
Industry Mall, see www.siemens.com/product?3RF Online configurator, see www.siemens.com/sirius/configurators
Conversion tool, see www.siemens.com/conversion-tool

Solid-state contactors for switching motors Switching functions


The solid-state contactors for switching motors are
"Instantaneous switching", because this method is particularly
suited for inductive loads. By distributing the ON point over the
entire sine curve of the mains voltage, disturbances are reduced
to a minimum.
Connection methods
You can choose between the following connection methods for
the solid-state contactors for switching motors:
Screw terminals
The screw connection system is the standard for industrial
controls. Open terminals and a plus-minus screw are just two
features of this technology. Two conductors of up to 6 mm² can
be connected in just one terminal.

6
Spring-loaded terminals
This innovative technology manages without any screw
connection. This means that very high vibration resistance is
Solid-state contactor for direct-on-line starting achieved. Two conductors of up to 2.5 mm² can be connected
to each terminal.
The solid-state contactors for switching motors are intended
for frequently switching on and off three-phase current operating Motor feeders
mechanisms up to 7.5 kW and reversing up to 3.0 kW.
The devices are constructed with complete insulation and The devices can use a link module to directly connect to
can be mounted directly on SIRIUS motor starter protectors, a motor starter protector. Also possible is the mounting of
overload relays and current monitoring relays, resulting in a very a 3RB30/3RB31 electronic overload relay (see page 7/95)
simple integration into motor feeders. or a 3RR2 current monitoring relay (see pages 10/47 and 10/55)
using a link adapter. The simultaneous mounting of a motor
These 3-phase solid-state contactors are equipped with starter protector and an overload or current monitoring relay is
a 2-phase control which is particularly suitable for typical motor not recommended for space and heat development reasons.
current circuits without connecting to the neutral conductor.
Rapid-switching fuseless and fused motor feeders can thereby
Solid-state contactors for switching motors are available in two be implemented in a time-saving manner.
versions:
Selecting solid-state contactors
• SIRIUS 3RF34 solid-state contactors, 3-phase:
These 2-phase controlled, instantaneous switching solid-state The solid-state contactors are selected on the basis of details of
contactors in the insulating enclosure are offered with a width the network, the load and the ambient conditions.
of 45 mm up to 5.2 A – and with a width of 90 mm up to 16 A.
They allow the operation of motors up to 7.5 kW. The following procedure is recommended:
• SIRIUS 3RF34 solid-state reversing contactors, 3-phase: • Determine the rated current of the load and the mains voltage
The integration of four conducting paths to a reverse switch, • Select a solid-state contactor with the same or higher rated
combined in one enclosure, makes this device a particularly current than the load
compact solution. Compared to conventional systems, • Testing of the maximum permissible switching frequency
for which two contactors are required, it is possible to save up based on the characteristic curves (see "More information" ➞
to 50% width with the 3-phase reversing contactors. Devices "Product information", page 6/161). To do this, the starting
with a width of 45 mm cover motors up to 2.2 kW – and those current, the starting time and the motor load in the operating
with a width of 90 mm cover motors up to 3 kW. phase must be known.
Note: • If the permissible switching frequency is under the desired
frequency, it is possible to achieve an increase only by
In accordance with the product standard IEC 60947-4-2,
overdimensioning the motor and the solid-state contactor!
the motor contactors are designed for motors with maximum
starting current conditions of I/Ie  8. For configuring motors with The correct device size can be determined by entering the
higher starting current conditions (typically I/Ie  8), the data in network and motor data along with the application and ambient
the Equipment Manual for 3RF34 solid-state switching devices conditions.
must be taken into account, see
https://support.industry.siemens.com/cs/ww/en/view/60298187.

Siemens IC 10 · 2023 6/159


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RF34 solid-state switching devices for switching motors
Solid-state contactors
General data
Short-circuit protection Alternatively, if there is lower loading, protection can also
be provided by standard fuses or miniature circuit breakers.
Despite the rugged power semiconductors that are used, This protection is achieved by overdimensioning the solid-state
solid-state switching devices respond more sensitively to short switching devices accordingly.
circuits in the load feeder. Consequently, special precautions
have to be taken against destruction, depending on the type
of design.
Siemens generally recommends using SITOR semiconductor
fuses. These fuses also provide protection against destruction in
the event of a short circuit even when the solid-state contactors
and solid-state relays are fully utilized.
Article number scheme
Product versions Article number
Solid-state contactors 3RF34 @ @ – @ @ @ @ @ 3-phase
Rated operational current 3.8 A 0 3 Only for reversing contactor
5.2 A (5.4 A for reversing contactor) 0 5
9.2 A (7.4 A for reversing contactor) 1 0
12.5 A 1 2 Only for solid-state contactor
16 A 1 6 Only for solid-state contactor
Connection type Screw terminals 1
Spring-loaded terminals 2
6

Switching function Instantaneous switching B


Number of controlled phases 2-phase B
Reversing contactor D
Rated control supply voltage Us 24 V DC 0
110 ... 230 V AC 2
Rated operational voltage Ue 48 ... 460 V AC 4
48 ... 600 V AC 6 Blocking voltage 1 600 V, only for solid-state contactor
Example 3RF34 1 0 – 1 B B 0 4
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

■ Benefits
• Insulated enclosure with integrated heat sink, "ready to use" • Variety of connection methods
• Compact and space-saving design • Plug-in control connection
• Reversing contactors with integrated interlocking • Display via LEDs
• High degree of protection • Wide voltage range for AC control supply voltage
• Integrated mounting foot for snapping onto a DIN rail or for
mounting on a support plate

■ Application
Use in load feeders Standards and approvals
There is no typical design of a load feeder with solid-state relays • IEC 60947-4-2
or solid-state contactors; instead, the great variety of connection • UL 508, CSA for North America1)
methods and control voltages offers universal application • CE marking for Europe
opportunities.
• C-Tick approval for Australia
SIRIUS solid-state relays and solid-state contactors can be
installed in fuseless or fused feeders, as required. • CCC approval for China
1) Please note: Use overvoltage protection device;
See Configuration Manual for load feeders, max. cut-off-voltage 6 000 V;
https://support.industry.siemens.com/cs/ww/en/view/39714188. min. energy handling capability 100 J.

6/160 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RF34 solid-state switching devices for switching motors
Solid-state contactors
General data

■ Technical specifications
Type 3RF3405-1BB.. 3RF3410-1BB.., 3RF3405-2BB.. 3RF3410-2BB..,
3RF3403-1BD.., 3RF3412-1BB.., 3RF3412-2BB..,
3RF3405-1BD.. 3RF3416-1BB.. 3RF3416-2BB..
3RF3410-1BD..

H
Dimensions (W x H x D)
• 3RF34..-1BB.. mm 45 x 95 x 96.5 90 x 95 x 96.5 45 x 95 x 96.5 90 x 95 x 96.5

D
W
• 3RF34..-1BD.. mm 45 x 95 x 108.5 90 x 95 x 108.5 -- --
General technical specifications
Ambient temperature
• During operation, derating from 40 °C °C -25 ... +60
• During storage °C -55 ... +80
Installation altitude m 0 ... 1 000; derating over 1 000 m on request
Shock resistance according to IEC 60068-2-27 g/ms 15/11
Vibration resistance according to IEC 60068-2-6 g 2
Degree of protection IP on the front IP20
according to IEC 60529
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching from the front
Insulation strength at 50/60 Hz V rms 4 000
(main/control circuit to floor)
Electromagnetic compatibility (EMC)

6
• Emitted interference according to IEC 60947-4-2
- Conducted interference voltage Class A for industrial applications1)
- Emitted, high-frequency interference voltage Class A for industrial applications
• Interference immunity
- Electrostatic discharge kV Contact discharge: 4; air discharge: 8;
according to IEC 61000-4-2 Behavior criterion 2
(corresponds to degree of severity 3)
- Induced RF fields MHz 0.15 ... 80;
according to IEC 61000-4-6 140 dBµV; behavior criterion 1
- Burst according to IEC 61000-4-4 kV 2; at 5 kHz; behavior criterion 2
- Surge according to IEC 61000-4-52) kV Conductor - ground 2; conductor - conductor 1; behavior criterion 2
Connection type Screw terminals Spring-loaded terminals

Operating devices Standard screwdriver size 2 and Pozidriv 2 3.0 x 0.5 and 3.5 x 0.5
Conductor cross-sections, main contacts
• Solid mm2 2 x (1.5 ... 2.5)3), 2 x (2.5 ... 6)3) 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve mm2 2 x (1 ... 2.5)3), 2 x (2.5 ... 6)3), 1 x 10 2 x (0.5 ... 1.5)
• Finely stranded without end sleeve mm2 -- 2 x (0.5 ... 2.5)
• AWG cables, solid or stranded AWG 2 x (14 ... 10) 2 x (18 ... 14)
Conductor cross-sections, auxiliary/control contacts
• With/without end sleeve mm2 1 x (0.5 ... 2.5), 2 x (0.5 ... 1.0) 0.5 ... 2.5
• AWG cables, solid or stranded AWG 20 ... 12 20 ... 12
Permissible mounting position ±10° ±10°

NSB0_01703

1) These products were built as Class A devices. The use of these devices in 2) The following applies for reversing contactors: To maintain the values,
residential areas could result in radio interference. In this case it may be a 3TX7462-3L surge suppressor should be used between phases L1 and
required to introduce additional interference suppression measures. L3 as close as possible to the reversing contactor.
3) If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in one of the ranges specified.

■ More information
For more information, see Product information and technical specifications
• System Manual for modular system, For product data sheets with detailed technical specifications
https://support.industry.siemens.com/cs/ww/en/view/60311318 and dimensional drawings, see
• Equipment Manual for 3RF34 solid-state switching devices, https://support.industry.siemens.com/cs/ww/en/ps/16237/td.
https://support.industry.siemens.com/cs/ww/en/view/60298187 For more information, please enter the article number of the
required device under the tab "Product List".

Siemens IC 10 · 2023 6/161


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RF34 solid-state switching devices for switching motors
Solid-state contactors
SIRIUS 3RF34 solid-state contactors, 3-phase

■ Technical specifications
More information
System Manual for modular system, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16237/faq
https://support.industry.siemens.com/cs/ww/en/view/60311318
Equipment Manual for 3RF34 solid-state switching devices, see
https://support.industry.siemens.com/cs/ww/en/view/60298187

Type 3RF3405-.BB.. 3RF3410-.BB.. 3RF3412-.BB.. 3RF3416-.BB..


Fuseless design
with 3RV2 motor starter protector, CLASS 10
Rated operational current IAC-53a1)
According to IEC 60947-4-2
• At 40 °C A 5.2 (4.5) 9.2 12.5 16
• UL/CSA, at 50 °C A 4.6 (4.0) 8.4 11.5 14
• At 60 °C A 4.2 (3.5) 7.6 10.5 12.5
Power loss at IAC-53a
• At 40 °C W 10 (8) 16 22 28
Short-circuit protection with type of
coordination "1"
At operational voltage Ue up to 440 V
• Motor starter protectors Type 3RV2011-1GA10 3RV2011-1JA10 3RV2011-1KA10 3RV2011-4AA10
• Current Iq kA 50 5 3
6

1)
The reduced values in brackets apply to a directly mounted motor starter
protector and simultaneous side-by-side mounting.

Type 3RF3405-.BB.4 3RF3405-.BB.6 3RF3410-.BB.. 3RF3412-.BB.4 3RF3412-.BB.6 3RF3416-.BB..


Fused design
with directly connected 3RB3 overload relay
Rated operational current IAC-53a
According to IEC 60947-4-2
• At 40 °C A 4 7.8 9.5 11
• UL/CSA, at 50 °C A 3.6 7 8.5 10
• At 60 °C A 3.2 6.2 7.6 9
Power loss at IAC-53a
• At 40 °C W 7 13 16 18
Minimum load current A 0.1 0.5
Max. off-state current mA 10
Rated peak withstand current Itsm A 200 600 1 200 1 150
I2t value A2s 200 1 800 7 200 6 600

Type 3RF34..-.BB.4 3RF34..-.BB.6


Main circuit
Controlled phases 2-phase
Rated operational voltage Ue V AC 48 ... 480 48 ... 600
• Operating range V AC 40 ... 506 40 ... 660
• Rated frequency Hz 50/60  10%
Rated insulation voltage Ui V 600
Rated impulse withstand voltage Uimp kV 6
Blocking voltage V 1 200 1 600
Rate of voltage rise V/µs 1 000

Type 3RF34..-.BB0. 3RF34..-.BB2.


Control circuit
Method of operation DC operation AC operation
Rated control supply voltage Us V 24 110 ... 230
Rated frequency Hz -- 50/60  10%
of the control supply voltage
Control supply voltage, max. V 30 253
Typical actuating current mA 20 15
Response voltage V 15 90
Drop-out voltage V 5 < 40
Operating times
• ON-delay ms 1 5
• OFF-delay ms 1 + max. one half-wave 30 + max. one half-wave

6/162 Siemens IC 10 · 2023


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RF34 solid-state switching devices for switching motors
Solid-state contactors
IE3 ready IE4 ready IE3/IE4 ready SIRIUS 3RF34 solid-state contactors, 3-phase

■ Selection and ordering data


Motor contactors · Instantaneous switching · 2-phase controlled
Rated Rated power Rated control supply Screw terminals PU PS* PG
operational at Ie and Ue voltage Us (UNIT,
current Ie SET, M)
400 V Article No. Price
A kW V per PU
Rated operational voltage Ue
48 ... 480 V AC
5.2 2.2 24 DC 3RF3405-1BB04 1 1 unit 41C
9.2 4.0 3RF3410-1BB04 1 1 unit 41C
12.5 5.5 3RF3412-1BB04 1 1 unit 41C
16 7.5 3RF3416-1BB04 1 1 unit 41C
5.2 2.2 110 ... 230 AC 3RF3405-1BB24 1 1 unit 41C
9.2 4.0 3RF3410-1BB24 1 1 unit 41C
12.5 5.5 3RF3412-1BB24 1 1 unit 41C
16 7.5 3RF3416-1BB24 1 1 unit 41C
3RF3405-1BB
Rated operational voltage Ue
48 ... 600 V AC, blocking voltage 1 600 V
5.2 2.2 24 DC 3RF3405-1BB06 1 1 unit 41C
9.2 4.0 3RF3410-1BB06 1 1 unit 41C

6
12.5 5.5 3RF3412-1BB06 1 1 unit 41C
16 7.5 3RF3416-1BB06 1 1 unit 41C
5.2 2.2 110 ... 230 AC 3RF3405-1BB26 1 1 unit 41C
9.2 4.0 3RF3410-1BB26 1 1 unit 41C
12.5 5.5 3RF3412-1BB26 1 1 unit 41C
16 7.5 3RF3416-1BB26 1 1 unit 41C

3RF3410-1BB

Rated Rated power Rated control supply Spring-loaded PU PS* PG


operational at Ie and Ue voltage Us terminals (UNIT,
current Ie SET, M)
400 V Article No. Price
A kW V per PU
Rated operational voltage Ue
48 ... 480 V AC
5.2 2.2 24 DC 3RF3405-2BB04 1 1 unit 41C
9.2 4.0 3RF3410-2BB04 1 1 unit 41C
12.5 5.5 3RF3412-2BB04 1 1 unit 41C
16 7.5 3RF3416-2BB04 1 1 unit 41C
5.2 2.2 110 ... 230 AC 3RF3405-2BB24 1 1 unit 41C
9.2 4.0 3RF3410-2BB24 1 1 unit 41C
12.5 5.5 3RF3412-2BB24 1 1 unit 41C
16 7.5 3RF3416-2BB24 1 1 unit 41C
3RF3405-2BB
Rated operational voltage Ue
48 ... 600 V AC, blocking voltage 1 600 V
5.2 2.2 24 DC 3RF3405-2BB06 1 1 unit 41C
9.2 4.0 3RF3410-2BB06 1 1 unit 41C
12.5 5.5 3RF3412-2BB06 1 1 unit 41C
16 7.5 3RF3416-2BB06 1 1 unit 41C
5.2 2.2 110 ... 230 AC 3RF3405-2BB26 1 1 unit 41C
9.2 4.0 3RF3410-2BB26 1 1 unit 41C
12.5 5.5 3RF3412-2BB26 1 1 unit 41C
16 7.5 3RF3416-2BB26 1 1 unit 41C

3RF3410-2BB

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 6/163
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RF34 solid-state switching devices for switching motors
Solid-state contactors
SIRIUS 3RF34 solid-state contactors, 3-phase

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Link modules between solid-state contactor and motor starter protector


Link modules Screw terminals
Between solid-state contactor and motor starter protector
with screw terminals
For 3RV2 motor starter protectors size S00/S0 3RA2921-1BA00 1 1 unit 41B

3RA2921-1BA00
Link adapters between solid-state contactor and overload relay
Link adapters
For direct mounting of 3RB3 overload relays or
3RR2 current monitoring relays to the solid-state
contactor with screw terminals
3RF3900-0QA88
The adapter is snapped onto the enclosure of the 3RF3900-0QA88 1 1 unit 41C
3RF34 contactor and accommodates the fixing hooks
of the 3RB3 overload relays or the 3RR2 current monitoring
relays for direct mounting.
6

Insulation stop for securely holding back the conductor insulation,


on conductors up to 1 mm2
Insulation stop strip Spring-loaded
For all SIRIUS devices with spring-loaded terminals terminals
Can be inserted in the cable entry of the spring-loaded 3RT2916-4JA02 1 20 units 41B
3RT2916-4JA02 terminal (no more than two strips per contactor required;
removable in pairs)
For terminals with a conductor cross-section up to 2.5 mm2
Tools for opening spring-loaded terminals
Screwdrivers
For all SIRIUS devices with spring-loaded terminals
Length approx. 200 mm, size 3.0 mm x 0.5 mm, 3RA2908-1A 1 1 unit 41B
titanium gray/black, partially insulated

3RA2908-1A
Control connectors
Control connectors
For solid-state contactors with spring-loaded terminals
With two clamping points per contact 3RF2900-2TB88 1 10 units 41C

3RF2900-2TB88
Blank labels
Unit labeling plates
For SIRIUS devices1)
10 mm x 7 mm, titanium gray 3RT2900-1SB10 100 816 41B
units
20 mm x 7 mm, titanium gray 3RT2900-1SB20 100 340 41B
IC01_00181

units
Adhesive labels
3RT2900-1SB20 For SIRIUS devices
19 mm x 6 mm, titanium gray 3RT2900-1SB60 100 3060 41B
units
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


6/164 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RF34 solid-state switching devices for switching motors
Solid-state contactors
SIRIUS 3RF34 solid-state reversing contactors, 3-phase

■ Technical specifications
More information
System Manual for modular system, see Equipment Manual for 3RF34 solid-state switching devices, see
https://support.industry.siemens.com/cs/ww/en/view/60311318 https://support.industry.siemens.com/cs/ww/en/view/60298187
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16237/faq

Type 3RF3403-.BD.4 3RF3405-.BD.4 3RF3410-.BD.4


Fuseless design
with 3RV2 motor starter protector, CLASS 10
Rated operational current IAC-53a1)
According to IEC 60947-4-2
• At 40 °C A 3.8 (3.4) 5.4 (4.8) 7.4
• UL/CSA, at 50 °C A 3.5 (3.1) 5 (4.3) 6.8
• At 60 °C A 3.2 (2.8) 4.6 (3.8) 6.2
Power loss at IAC-53a
• At 40 °C W 7 (6) 9 (8) 13
Short-circuit protection with type of
coordination "1"
At operational voltage Ue up to 440 V
• Motor starter protectors Type 3RV2011-1FA10 3RV2011-1GA10 3RV2011-1JA10
• Current Iq kA 50 10
1)

6
The reduced values in brackets apply to a directly mounted motor starter
protector and simultaneous side-by-side mounting.

Type 3RF3403-.BD.4 3RF3405-.BD.4 3RF3410-.BD.4


Fused design
with directly connected 3RB3 overload relay
Rated operational current IAC-53a
According to IEC 60947-4-2
• At 40 °C A 3.8 5.4 7.4
• UL/CSA, at 50 °C A 3.5 5 6.8
• At 60 °C A 3.2 4.6 6.2
Power loss at IAC-53a
• At 40 °C W 6 8 16
Minimum load current A 0.5
Max. off-state current mA 10
Rated peak withstand current Itsm A 200 600
I2t value A2s 200 1 800

Type 3RF34..-.BD.4
Main circuit
Controlled phases 2-phase
Rated operational voltage Ue1) V AC 48 ... 480
• Operating range V AC 40 ... 506
• Rated frequency Hz 50/60  10%
Rated insulation voltage Ui V 600
Rated impulse withstand voltage Uimp kV 6
Blocking voltage V 1 200
Rate of voltage rise V/µs 1 000
1)
To reduce the risk of a phase short circuit due to overvoltage, We recommend a design with semiconductor protection as short-circuit
we recommend using a varistor type 3TX7462-3L between the phases L1 protection.
and L3 as close as possible to the switchgear.

Type 3RF34..-.BD0. 3RF34..-.BD2.


Control circuit
Method of operation DC operation AC operation
Rated control supply voltage Us V 24 110 ... 230
Rated frequency Hz -- 50/60  10%
of the control supply voltage
Control supply voltage, maximum V 30 253
Typical actuating current mA 15 10
Response voltage V 15 90
Drop-out voltage V 5 < 40
Operating times1)
• ON-delay ms 5 20
• OFF-delay ms 5 + max. one half-wave 10 + max. one half-wave
• Interlocking time ms 60 ... 100 50 ... 100
1)
Notice! Risk of phase short circuit in automatic mode.
The control inputs must not be actuated until a delay of 40 ms has expired
after the main voltage is applied.

Siemens IC 10 · 2023 6/165


© Siemens 2023

Switching devices – Soft starters and solid-state switching devices


SIRIUS 3RF34 solid-state switching devices for switching motors
Solid-state contactors
SIRIUS 3RF34 solid-state reversing contactors, 3-phase IE3 ready IE4 ready IE3/IE4 ready

■ Selection and ordering data


Reversing contactors · Instantaneous switching · 2-phase controlled
Rated Rated power Rated control supply Screw terminals PU PS* PG
operational at Ie and Ue voltage Us (UNIT,
current Ie SET, M)
400 V Article No. Price
A kW V per PU
Rated operational voltage Ue 48 ... 480 V AC
3.8 1.5 24 DC 3RF3403-1BD04 1 1 unit 41C
5.4 2.2 3RF3405-1BD04 1 1 unit 41C
7.4 3.0 3RF3410-1BD04 1 1 unit 41C

3RF3403-1BD
3.8 1.5 110 ... 230 AC 3RF3403-1BD24 1 1 unit 41C
5.4 2.2 3RF3405-1BD24 1 1 unit 41C
7.4 3.0 3RF3410-1BD24 1 1 unit 41C
6

3RF3410-1BD

■ Accessories
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Link modules between solid-state contactor and motor starter protector


Link modules Screw terminals
Between solid-state reversing contactor and motor starter
protector with screw terminals
For 3RV2 motor starter protectors, size S00/S0 3RA2921-1BA00 1 1 unit 41B

3RA2921-1BA00
Link adapters between solid-state contactor and overload relay
Link adapters
For direct mounting of 3RB3 overload relays or 3RR2 current
monitoring relays to the solid-state contactor with screw
terminals
3RF3900-0QA88
The adapter is snapped onto the enclosure of the 3RF3900-0QA88 1 1 unit 41C
3RF34 contactor and accommodates the fixing hooks
of the 3RB3 overload relays or the 3RR2 current monitoring
relays for direct mounting.
Blank labels
Unit labeling plates
For SIRIUS devices1)
10 mm x 7 mm, titanium gray 3RT2900-1SB10 100 816 41B
units
20 mm x 7 mm, titanium gray 3RT2900-1SB20 100 340 41B
IC01_00181

units
Adhesive labels
3RT2900-1SB20 For SIRIUS devices
19 mm x 6 mm, titanium gray 3RT2900-1SB60 100 3060 41B
units
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


6/166 Siemens IC 10 · 2023 Illustrations are approximate
7
© Siemens 2023

Protection equipment

Price groups
PG 12P, 14O, 41B, 41E, 41F, 41G, 41H,
41J, 42F, 42J

7/2 Introduction

Motor starter protectors/


circuit breakers
SIRIUS 3RV2 motor starter
protectors/circuit breakers
7/6 General data
7/27 For motor protection
7/35 For motor protection with
overload relay function
7/37 For starter combinations
7/40 For transformer protection
7/44 For system protection
7/45 For system protection according to
UL 489/CSA C22.2 No. 5
7/46 For transformer protection according to
UL 489/CSA C22.2 No. 5
Accessories
7/47 - Mountable accessories

7
7/50 - Busbar accessories
7/54 - Rotary operating mechanisms
7/57 - Mounting accessories
7/64 - Enclosures and front plates
7/67 3RV29 infeed system
SIRIUS 3RV1 motor starter
protectors/circuit breakers
7/73 For fuse monitoring
7/74 For distance protection
7/75 For motor protection

Overload relays
7/76 General data
SIRIUS 3RU2 thermal overload relays
7/83 3RU2 for standard applications
7/93 Accessories
SIRIUS 3RB3 electronic overload relays
7/95 3RB30, 3RB31 for standard
applications
7/105 Accessories
SIRIUS 3RB2 electronic overload relays
7/107 3RB20, 3RB21 for standard
applications
7/117 Accessories for 3RB20, 3RB21
7/119 3RB22, 3RB23
for high-feature applications
7/127 3RB24 for IO-Link for high-feature
applications
7/134 Current measuring modules for 3RB22,
3RB23 and 3RB24
7/138 Accessories for 3RB22, 3RB23, 3RB24

Siemens IC 10 · 2023
© Siemens 2023

Protection equipment

Introduction

■ Overview

Type 3RV20 3RV21 3RV23 3RV24 3RV27 3RV28


SIRIUS 3RV2 motor starter protectors/circuit breakers
Applications
• System protection ✓1)/ ✓1) -- -- ✓ ✓
3RV20..-.....-0DA02)
• Motor protection ✓ -- -- -- -- --
• Motor protection with overload -- ✓ -- -- -- --
relay function
• Starter combinations -- -- ✓ -- -- --
• Transformer protection -- -- -- ✓/ -- ✓
3RV24..-.....-0DA02)
Size S00, S0, S2, S3 S00, S0, S2, S3 S00, S0, S2, S3 S00, S0, S2 S00, S0, S3 S00, S0
Rated current In
• Size S00 A Up to 16 Up to 16 Up to 16 Up to 16 Up to 15 Up to 15
7

• Size S0 A Up to 40 Up to 32 Up to 40 Up to 25 Up to 22 Up to 22
• Size S2 A Up to 80 Up to 80 Up to 80 Up to 65 -- --
• Size S3 A Up to 100 Up to 100 Up to 100 -- Up to 70 --
Rated operational voltage Ue V 690 AC3) 690 AC3) 690 AC3) 690 AC3) 690 AC 690 AC
according to IEC
Rated frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60
Trip class CLASS 10 (S00 ... S3), CLASS 10 -- CLASS 10 -- --
CLASS 20 (S2, S3)
Thermal overload release A 0.11 ... 0.16 to 0.11 ... 0.16 to None4) 0.11 ... 0.16 to 0.16 ... 70 0.16 ... 22
A 80 ... 100 80 ... 100 54 ... 65 Non-adjustable Non-adjustable
Electronic release
A multiple of the rated current 13 times 13 times 13 times 20 times 13 times 20 times
Short-circuit breaking kA 20/55/65/100 55/65/100 20/55/65/100 55/65/100 5) 5)
capacity Icu at 400 V AC
Pages 7/27 ... 7/34 7/35, 7/36 7/37 ... 7/39 7/40, 7/41 7/45 7/46

Accessories
For sizes S00 S0 S2 S3 S00 S0 S2 S3 S00 S0 S2 S3 S00 S0 S2 S00 S0 S3 S00 S0
Auxiliary switches ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓6) ✓ ✓
Signaling switches ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ -- -- -- -- --
Undervoltage releases ✓ ✓ ✓ ✓ -- -- -- -- ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Shunt releases ✓ ✓ ✓ ✓ -- -- -- -- ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Isolator modules ✓ ✓ ✓ -- ✓ ✓ ✓ -- ✓ ✓ ✓ -- ✓ ✓ ✓ -- -- -- -- --
Insulated 3-phase busbar ✓ ✓ ✓ -- -- -- ✓ -- ✓ ✓ ✓ -- ✓ ✓ ✓ ✓ ✓ -- ✓ ✓
system
Busbar adapters ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ -- --
Door-coupling rotary operating ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
mechanisms
Link modules ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ -- -- -- -- --
Enclosures for surface mounting ✓ ✓ ✓ -- ✓ ✓ ✓ -- ✓ ✓ ✓ -- ✓ ✓ ✓ -- -- -- -- --
Enclosures for flush mounting ✓ ✓ -- -- ✓ ✓ -- -- ✓ ✓ -- -- ✓ ✓ -- -- -- -- -- --
Front plates ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ -- -- -- -- --
Infeed system ✓ ✓ -- -- -- -- -- -- ✓ ✓ -- -- ✓ ✓ -- ✓ ✓ -- ✓ ✓
Sealable scale covers for setting ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ -- -- -- -- ✓ ✓ ✓ -- -- -- -- --
knobs
Pages 7/47 ... 7/66
✓ Has this function or can use this accessory 5) According to UL 489 at 480 Y/277 V AC: 65 kA or 50 kA.
6)
-- Does not have this function or cannot use this accessory Only lateral auxiliary switches can be used
1) For symmetrical loading of the three phases.
2)
For 1-phase, 2-phase and 3-phase asymmetrical loading of the three phases.
3)
With molded-plastic enclosure 500 V AC.
4) For overload protection of the motors, appropriate overload relays must
be used.

7/2 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment

Introduction

Type 3RV1611-0BD10 3RV1611-1.G14 3RV1011


SIRIUS 3RV1 motor starter protectors/circuit breakers
Applications
• Motor protection -- -- ✓
• Fuse monitoring ✓ -- --
• Voltage transformer circuit breakers for distance protection -- ✓ --
Size S00 S00 S00
Rated current In A 0.2 Up to 3 Up to 12
Rated operational voltage Ue according to IEC V 690 AC1) 400 AC 690 AC
Rated frequency Hz 50/60 162/3 ... 60 50/60
Trip class -- -- CLASS 10
Thermal overload release A 0.2 1.4 ... 3 0.11 ... 0.16 to 9 ... 12
Electronic release
A multiple of the rated current 6 times 4 ... 7 times 13 times
Short-circuit breaking capacity Icu at 400 V AC kA 100 50 100/50
Pages 7/73 7/74 7/75

7
Accessories
For sizes S00 S00 S00
Auxiliary switches ✓ ✓ ✓
Further accessories -- -- ✓
Pages 7/73 7/74 7/47 ... 7/72
1)
✓ Has this function or can use this accessory With molded-plastic enclosure 500 V AC.
-- Does not have this function or cannot use this accessory

Siemens IC 10 · 2023 7/3


© Siemens 2023

Protection equipment

Introduction

Thermal overload relays Electronic overload relays


for standard applications for standard applications
Type 3RU21 3RB30 3RB31
SIRIUS overload relays
Applications
• System protection ✓1) ✓1) ✓1)
• Motor protection ✓ ✓ ✓
• Alternating current, 3-phase ✓ ✓ ✓
• Alternating current, 1-phase ✓ -- --
• Direct current ✓ -- --
Size contactor S00, S0, S2, S3 S00, S0, S2, S3 S00, S0, S2, S3
Rated operational current Ie
• Size S00 A Up to 16 Up to 16 Up to 16
• Size S0 A Up to 40 Up to 40 Up to 40
• Size S2 A Up to 80 Up to 80 Up to 80
7

• Size S3 A Up to 100 Up to 115 Up to 115


Rated operational voltage Ue V 690 AC 690 AC 690 AC
Rated frequency Hz 50/60 50/60 50/60
Trip class CLASS 10, 10A CLASS 10E, 20E CLASS 5E, 10E, 20E, 30E
(adjustable)
Thermal overload release A 0.11 ... 0.16 to -- --
A 80 ... 100
Electronic overload releases A -- 0.1 ... 0.4 to 0.1 ... 0.4 to
A 32 ... 115 32 ... 115
Pages 7/89 ... 7/92 7/102, 7/103 7/104

Accessories
For sizes S00 S0 S2 S3 S00 S0 S2 S3 S00 S0 S2 S3
Terminal supports for stand-alone ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
installation
Mechanical RESET ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Cable releases for RESET ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Electrical Remote RESET ✓ ✓ ✓ ✓ -- -- -- -- Integrated in the unit
Terminal covers for box terminal -- -- ✓ ✓ -- -- ✓ ✓ -- -- ✓ ✓
Sealable covers for setting knobs ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Pages 7/93, 7/94 7/105, 7/106 7/105, 7/106
1)
✓ Has this function or can use this accessory The units are responsible in the main circuit for overload protection of the
-- Does not have this function or cannot use this accessory assigned electrical loads (e.g. motors), feeder cable, and other switching
and protection devices in the respective load feeder.

7/4 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment

Introduction

Electronic overload relays Electronic overload


relays for IO-Link
for standard applications for high-feature applications for high-feature
applications
Type 3RB20 3RB21 3RB22, 3RB23 3RB24
SIRIUS overload relays
Applications
• System protection ✓1) ✓1) ✓1)
• Motor protection ✓ ✓ ✓
• Alternating current, 3-phase ✓ ✓ ✓
• Alternating current, 1-phase -- -- ✓
• Direct current -- -- --
Size contactor S6 ... S12 S6 ... S12 S00 ... S12
Rated operational current Ie
• Sizes S00 and S0 A -- -- Up to 25 and 45 mm width

7
with current measuring modules
3RB2906-2BG1/3RB2906-2DG1
• Size S2 A -- -- Up to 100 and 55 mm width
• Size S3 A -- -- with current measuring module
3RB2906-2JG1
• Size S6 A Up to 200 Up to 200 Up to 200 and 120 mm width
with current measuring modules
3RB2956-2TH2/3RB2956-2TG2
• Size S10/S12 A Up to 630 Up to 630 Up to 630 and 145 mm width
with current measuring module
3RB2966-2WH2
• Size 14 (3TF68/3TF69) A Up to 630 Up to 630 Up to 820
with current measuring module
3RB2906-2BG1 and
transformer 3UF1868-3GA00
Rated operational voltage Ue V 690/1 000 AC 690/1 000 AC 690/1 000 AC2)
Rated frequency Hz 50/60 50/60 50/60
Trip class CLASS 10, 20 CLASS 5, 10, 20, 30 CLASS 5, 10, 20, 30
adjustable adjustable
Thermal overload release A -- -- --
Electronic overload releases A 50 ... 200 to 50 ... 200 to 0.3 ... 3 to
A 160 ... 630 160 ... 630 63 ... 630
Pages 7/114, 7/115 7/116 7/125, 7/126, 7/137 7/133, 7/137

Accessories
For sizes S6 S10/S12 S6 S10/S12 S00 S0 S2 S3 S6 S10/S12
3) 3) 3) 3) 3) 3) 3) 3) 3) 3)
Terminal supports for stand-alone
installation
Mechanical RESET ✓ ✓ ✓ ✓ -- -- -- -- -- --
Cable releases for RESET ✓ ✓ ✓ ✓ -- -- -- -- -- --
Electrical Remote RESET -- -- Integrated in the unit Integrated in the unit
Terminal covers ✓ ✓ ✓ ✓ -- -- -- ✓ ✓ ✓
Sealable covers for setting knobs ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Operator panel for 3RB24 evaluation -- -- -- -- ✓ ✓ ✓ ✓ ✓ ✓
module
Pages 7/117, 7/118 7/117, 7/118 7/137 ... 7/139
1)
✓ Has this function or can use this accessory The units are responsible in the main circuit for overload protection of the
-- Does not have this function or cannot use this accessory assigned electrical loads (e.g. motors), feeder cable, and other switching
and protection devices in the respective load feeder.
2)
With reference to the 3RB29.6 current measuring modules.
3) Stand-alone installation without accessories is possible.

Siemens IC 10 · 2023 7/5


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

■ Overview
More information
Homepage, see www.siemens.com/sirius-circuit-breakers Application Manual for switching devices with IE3 and IE4 motors, see
Industry Mall, see www.siemens.com/product?3RV2 https://support.industry.siemens.com/cs/ww/en/view/94770820
TIA Selection Tool Cloud (TST Cloud), see System Manual for modular system, see
www.siemens.com/tstcloud/?node=MotorStarterProtector https://support.industry.siemens.com/cs/ww/en/view/60311318
Conversion tool, see www.siemens.com/conversion-tool Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60279172
Certificates, see https://support.industry.siemens.com/cs/ww/en/ps/16245/cert

The following illustration shows 3RV2 motor starter protectors/ Accessories, see page 7/47 onwards.
circuit breakers with the accessories which can be mounted for the
sizes S00 to S3, see also "Introduction" ➞ "Overview", page 7/2.

7
Mountable accessories
1 Transverse auxiliary switch
2 Lateral auxiliary switch with 2 contacts
3 Lateral auxiliary switch with 4 contacts
8 4 Shunt release (can not be used with
8 3RV21 motor starter protectors)
5 Undervoltage release without/with
leading contacts (can not be used with
3RV21 motor starter protectors)
6 Signaling switch (can not be used with
3RV27 and 3RV28 circuit breakers)
7

7 Isolator module (can not be used


3 with 3RV2.4, 3RV27 and 3RV28 motor
starter protectors/circuit breakers)
IC01_00633b
8 Terminal block Type E (cannot be used
with 3RV2.4 motor starter protectors in
2 conjunction with transverse auxiliary
switch) or phase barriers
4

5
1

Mountable accessories for SIRIUS 3RV2 motor starter protectors/circuit breakers


The SIRIUS 3RV2 motor starter protectors/circuit breakers
are compact, current limiting motor starter protectors/
circuit breakers which are optimized for load feeders. The motor
starter protectors/circuit breakers are used for switching and
protecting three-phase motors of up to 55/45 kW at 400 V AC
and for other loads with rated currents of up to 100 A.
3RV2 motor starter protectors are usually approved according to
IEC and UL/CSA. According to UL 508/UL 60947-4-1, the 3RV2
motor starter protectors/circuit breakers in sizes S00 to S3 are
approved as:
• "Manual Motor Controllers"
• "Manual Motor Controllers" for "Group Installations"
• "Manual Motor Controllers Suitable for Tab Conductor
Motor starter protector with spring-loaded terminals, size S0 (left) and Protection in Group Installations"
motor starter protector with screw terminals, size S00 (right) • "Self-Protected Combination Motor Controllers (Type E)"
Please note that for this approval the 3RV20 motor starter
protectors must be equipped with additional infeed terminals
or phase barriers. For more information, see page 7/57.
Corresponding short-circuit values, see pages 7/9 to 7/17.

Video: SIRIUS 3RV2 circuit breakers - Motor protection for machinery


and plants (0.11 to 100 A)

7/6 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data
The 3RV2...-.....-0BA0 motor starter protectors/circuit breakers Connection methods
can be used at low ambient temperatures down to -50 °C.
The 3RV2 motor starter protectors/circuit breakers can be
3RV20..-.....-0DA0 motor starter protectors for system protection supplied with screw terminals and spring-loaded terminals.
according to IEC, 3RV24..-.....-0DA0 for transformer protection
according to IEC and 3RV27 and 3RV28 circuit breakers Screw terminals
according to UL 489 can be used for 1-phase, 2-phase and
3-phase loads, as these motor starter protectors/circuit breakers Spring-loaded terminals
do not have asymmetry detection.
The 3RV27 and 3RV28 are approved as circuit breakers The terminals are indicated in the corresponding
according to UL 489; they are a special version of the 3RV2 tables by the symbols shown on orange backgrounds.
motor starter protectors.
Voltage data
Thanks to their dimensions, the 3RV1011 motor starter
The data for 3-phase power systems according to
protectors are suitable for installation in enclosures or under
IEC 60947-4-1 are valid for the following line system
cramped installation conditions.
configurations:
.

Type of construction
Voltage Ue Line system configurations
The 3RV2 motor starter protectors are available in four sizes: Three-phase Three-phase
• Size S00 – width 45 mm, four-wire networks three-wire networks
max. rated current 16 A,
at 400 V AC suitable for three-phase motors up to 7.5 kW
• Size S0 – width 45 mm,

IC01_00703
max. rated current 40 A,

IC01_00709
at 400 V AC suitable for three-phase motors up to 18.5 kW
• Size S2 – width 55 mm,
max. rated current 80 A,
V V V
at 400 V AC suitable for three-phase motors up to 37 kW

7
230 -- 230
• Size S3 – width 70 mm,
max. rated current 100 A, 400 230/400 400
at 400 V AC suitable for three-phase motors up to 45/55 kW 440 260/440 440
500 -- 500
Circuit breakers according to UL 489
690 400/690 690 (only as from size S3)
The 3RV27 and 3RV28 circuit breakers are available in two or 1 000 -- 1 000
three sizes:
-- Not specified
• Size S00 – width 45 mm,
max. rated current 15 A, for 480 Y/277 V AC Use in hazardous areas
• Size S0 – width 45 mm, The 3RV20 motor starter protectors for motor protection (without
max. rated current 22 A, for 480 Y/277 V AC 3RV20..-.....-0BA0 and -0DA0) have certification in accordance
• Size S3 – width 70 mm, with both the European Explosion Protection Directive (ATEX)
max. rated current 70 A, for 480 Y/277 V AC and the International Explosion Protection Standard (IECEx).
In accordance with the European Directive (ATEX), the 3RV20
(without 3RV20..-.....-0BA0 and -0DA0) are able to switch and
protect explosion-proof motors of type of protection "Increased
Safety EEx e".
In accordance with the international guideline (IECEx), the
3RV20 (without 3RV20..-.....-0BA0 and -0DA0) are able to switch
and protect motors of the types "Increased Safety Ex e" or
"Flameproof enclosure Ex d".

Article number scheme


Product versions Article number
Motor starter protectors/circuit breakers 3RV2 @ @ @ – @ @ @ @ @ – @ @ @ @
Type of motor starter e.g. 0 = for motor protection/system protection @
protector/circuit breaker
Size e.g. 1 = 16 A (7.5 kW) for size S00 @
Breaking capacity e.g. 1 = standard switching capacity @
Setting range for overload release e.g. 1A = 1.1 ... 1.6 A @@
Trip class (CLASS) e.g. A = a (adjustable CLASS 10)/n (13 or 20 x In) @
Connection methods e.g. 1 = screw terminals @
With or without auxiliary switch e.g. 0 = without @
Special versions @@@@
Example 3RV2 0 1 1 – 1 A A 1 0
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

Siemens IC 10 · 2023 7/7


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

■ Application
Operating conditions Possible uses
3RV2 motor starter protectors/circuit breakers are suitable for The 3RV motor starter protectors/circuit breakers can be used:
use in any climate. They are intended for use in enclosed rooms • For short-circuit protection
in which no severe operating conditions (such as dust, caustic
vapors, hazardous gases) prevail. When installed in dusty and • For motor protection (also with overload relay function)
damp areas, suitable enclosures must be provided. • For system protection
3RV2 motor starter protectors/circuit breakers can optionally be • For short-circuit protection for starter combinations
fed from the top or from below. • For transformer protection
The permissible ambient temperatures, the maximum switching • As main and EMERGENCY OFF switches
capacities, the tripping currents and other boundary conditions • For operation in IT systems (IT networks)
can be found in the technical specifications and tripping
characteristics. • In hazardous areas (ATEX, IECEx)
• As circuit breakers according to UL 489 (3RV27 and 3RV28)
3RV2 motor starter protectors/circuit breakers are suitable for
operation in IT systems (IT networks). In this case, the different • For fuse monitoring
short-circuit breaking capacity in the IT system must be taken • For distance protection
into account, see page 7/11.
Use of SIRIUS protection devices in conjunction with
Since operational currents, starting currents and current peaks IE3 and IE4 motors
are different even for motors with identical power ratings due to
the inrush current, the motor ratings in the selection tables are Note:
only guide values. The specific rated and startup data of the For the use of 3RV2 motor starter protectors/circuit breakers
motor to be protected are always paramount to the choice of the in conjunction with highly efficient IE3 and IE4 motors, please
most suitable motor starter protector/circuit breaker. This also observe the information on dimensioning and configuring,
applies to motor starter protectors for transformer protection. see Application Manual.
7

For more information, see page 1/8.

7/8 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

■ Technical specifications
More information
System Manual for modular system, see Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60311318 https://support.industry.siemens.com/cs/ww/en/view/60279172
Configuration Manual for load feeders, see Technical specifications, see
https://support.industry.siemens.com/cs/ww/en/view/39714188 https://support.industry.siemens.com/cs/ww/en/ps/16245/td
For UL reports for the individual devices, see
https://support.industry.siemens.com/cs/ww/en/ps/16245/cert

Short-circuit breaking capacity Icu, Ics according to IEC 60947-2


The table shows the rated ultimate short-circuit breaking an upstream motor starter protector/circuit breaker with a limiter
capacity Icu and the rated service short-circuit breaking function.
capacity Ics of the 3RV motor starter protectors/circuit breakers
with different operational voltages dependent on the rated The maximum rated current of this back-up fuse is indicated in
current In of the motor starter protectors/circuit breakers. the tables. The rated ultimate short-circuit breaking capacity
then applies as specified on the fuse.
Power can be supplied to the motor starter protectors/
circuit breakers via the terminals at the top or at the bottom Fuseless design
without restricting the rated data. If the short-circuit current Motor starter protector/contactor assemblies for short-circuit
at the installation location exceeds the motor starter protector/ currents up to 150 kA can be ordered as 3RA2 fuseless load
circuit breaker's specified rated short-circuit breaking capacity, feeders, see page 8/5 onwards.
you will need to use a back-up fuse. It is also possible to install

Motor starter Rated current Up to 240 V AC1) Up to Up to Up to Up to 690 V AC1)


protectors/ In 400 V AC1)/415 V AC2) 440 V AC1)/460 V AC2) 500 V AC1)/525 V AC2)
circuit breakers Icu Ics Max. fuse Icu Ics Max. fuse Icu Ics Max. fuse Icu Ics Max. fuse Icu Ics Max. fuse
(gG) (gG)3) (gG)3) (gG)3) (gG)3)4)

7
Type A kA kA A kA kA A kA kA A kA kA A kA kA A
Size S00
3RV1011 0.16 ... 1 100 100 -- 100 100 -- 100 100 -- 100 100 -- 100 100 --
1.25, 1.6 100 100 -- 100 100 -- 100 100 -- 100 100 -- 2 2 20
2; 2.5 100 100 -- 100 100 -- 100 100 -- 10 10 35 2 2 35
3.2; 4 100 100 -- 100 100 -- 50 12.5 40 3 3 40 2 2 40
5; 6.3 100 100 -- 100 100 -- 50 12.5 50 3 3 50 2 2 40
8 100 100 -- 50 12.5 80 50 12.5 63 3 3 63 2 2 50
10 100 100 -- 50 12.5 80 10 10 63 3 3 63 2 2 50
12 100 100 -- 50 12.5 80 10 10 80 3 3 80 2 2 50
3RV2.11 0.16 ... 1.6 100 100 -- 100 100 -- 100 100 -- 100 100 -- 100 100 --
2; 2.5 100 100 -- 100 100 -- 100 100 -- 100 100 -- 10 10 25
3.2 100 100 -- 100 100 -- 100 100 -- 100 100 -- 10 10 32
4; 5 100 100 -- 100 100 -- 100 100 -- 100 100 -- 6 4 32
6.3 100 100 -- 100 100 -- 100 100 -- 100 100 -- 6 4 50
8 100 100 -- 100 100 -- 50 50 63 42 42 63 6 4 50
10 100 100 -- 100 100 -- 50 50 80 42 42 63 6 4 50
12.5 100 100 -- 100 100 -- 50 50 80 42 42 80 6 4 63
16 100 100 -- 55 30 100 50 12.5 80 10 5 80 4 4 63
3RV1611-0BD10 0.2 100 100 -- 100 100 -- 100 100 -- 100 100 -- 100 100 --
Size S0
3RV2.21 0.16 ... 1.6 100 100 -- 100 100 -- 100 100 -- 100 100 -- 100 100 --
2; 2.5 100 100 -- 100 100 -- 100 100 -- 100 100 -- 10 10 25
3.2 100 100 -- 100 100 -- 100 100 -- 100 100 -- 10 10 32
4; 5 100 100 -- 100 100 -- 100 100 -- 100 100 -- 6 4 32
6.3 100 100 -- 100 100 -- 100 100 -- 100 100 -- 6 4 50
8 100 100 -- 100 100 -- 50 50 63 42 42 63 6 4 50
10 100 100 -- 100 100 -- 50 50 80 42 42 63 6 4 50
12.5 100 100 -- 100 100 -- 50 50 80 42 42 80 6 4 63
16 100 100 -- 55 25 100 50 12.5 80 10 5 80 4 2 63
20 100 100 -- 55 25 125 50 10 80 10 5 80 4 2 63
22; 25 100 100 -- 55 25 125 50 10 100 10 5 80 4 2 63
28; 32 100 100 -- 55 25 125 30 10 125 10 5 100 4 2 100
36; 40 100 100 -- 20 10 125 12 8 125 6 3 100 3 2 100
3)
-- No back-up fuse required, since short-circuit-proof up to 100 kA Back-up fuse only required if short-circuit current at the installation location
1)
10% overvoltage. is > Icu.
4) Alternatively, fuseless limiter combinations for 690 V AC can also be used.
2) 5% overvoltage.

Siemens IC 10 · 2023 7/9


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

Motor starter Rated current Up to 240 V AC1) Up to Up to Up to Up to 690 V AC1)


protectors/ In 400 V AC1)/415 V AC2) 440 V AC1)/460 V AC2) 500 V AC1)/525 V AC2)
circuit breakers Icu Ics Max. fuse Icu Ics Max. fuse Icu Ics Max. fuse Icu Ics Max. fuse Icu Ics Max. fuse
(gG) (gG)3) (gG)3) (gG)3) (gG)3)4)
Type A kA kA A kA kA A kA kA A kA kA A kA kA A
Size S2
3RV2.31 14; 17 100 100 -- 65 30 100 50 25 100 12 6 63 5 3 63
20 100 100 -- 65 30 100 50 25 100 12 6 80 5 3 80
25 100 100 -- 65 30 100 50 15 100 12 6 80 5 3 80
32; 36 100 100 -- 65 30 125 50 15 125 10 5 100 4 2 100
40; 45 100 100 -- 65 30 160 50 15 125 10 5 100 4 2 100
52 100 100 -- 65 30 160 50 15 125 10 5 125 4 2 125
59; 65 100 100 -- 65 30 160 50 15 160 8 4 125 4 2 125
73; 80 100 100 -- 65 30 200 50 15 200 8 4 160 4 2 125
Size S2, with increased
switching capacity
3RV2.32 14; 17 100 100 -- 100 50 -- 65 30 100 18 10 63 8 5 63
20; 25 100 100 -- 100 50 -- 65 30 100 18 10 80 8 5 80
32 ... 45 100 100 -- 100 50 -- 65 30 125 15 8 100 6 4 100
52 100 100 -- 100 50 -- 65 30 125 15 8 125 6 4 125
59; 65 100 100 -- 100 50 -- 50 15 160 10 5 125 6 4 125
73; 80 100 100 -- 100 50 -- 50 15 200 10 5 160 6 4 125
Size S3
3RV2.41 40 100 100 -- 65 30 125 65 30 125 12 6 100 6 3 63
50 100 100 -- 65 30 125 65 30 125 12 6 100 6 3 80
63 100 100 -- 65 30 160 65 30 160 12 6 100 6 3 80
75 100 100 -- 65 30 160 65 30 160 8 4 125 5 3 100
84 ... 100 100 100 -- 65 30 160 65 30 160 8 4 125 5 3 125
7

Size S3, with increased


switching capacity
3RV2.42 40 100 100 -- 100 50 -- 100 50 -- 18 9 160 12 6 80
50 100 100 -- 100 50 -- 100 50 -- 15 7.5 160 10 5 100
63 100 100 -- 100 50 -- 70 50 200 15 7.5 160 7.5 4 100
75 100 100 -- 100 50 -- 70 50 200 10 5 160 6 3 125
84 ... 100 100 100 -- 100 50 -- 70 50 200 10 5 160 6 3 160
3RV2742 10 ... 70 100 100 -- 100 50 -- -- -- -- -- -- -- -- -- --
3)
-- No back-up fuse required, since short-circuit-proof up to 100 kA Back-up fuse only required if short-circuit current at the installation location
1)
10% overvoltage. is > Icu.
4) Alternatively, fuseless limiter combinations for 690 V AC can also be used.
2) 5% overvoltage.

7/10 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data
Short-circuit breaking capacity IcuIT in the IT system (IT network) according to IEC 60947-2
3RV motor starter protectors/circuit breakers are suitable for use If the short-circuit current at the installation location exceeds the
in IT systems. The values of Icu and Ics apply for the 3-pole short motor starter protector/circuit breaker's specified rated short-
circuit. In the case of a double ground fault in different phases circuit breaking capacity, you will need to use a back-up fuse.
at the input and output side of a motor starter protector/ The maximum rated current of this back-up fuse is indicated in
circuit breaker, the special short-circuit breaking capacity the tables. The rated short-circuit breaking capacity then applies
IcuIT applies. The specifications in the table below apply as specified on the fuse.
to 3RV motor starter protectors/circuit breakers.

Motor starter Rated current Up to 240 V AC1) Up to Up to Up to Up to 690 V AC1)3)


protectors/ In 400 V AC1)/415 V AC2) 440 V AC1)/460 V AC2) 500 V AC1)/525 V AC2) I Max. fuse
circuit breakers cuIT
IcuIT Max. fuse IcuIT Max. fuse IcuIT Max. fuse IcuIT Max. fuse (gG)4)
(gG)4) (gG)4)5)
(gG)4)
(gG) 4)

Type A kA A kA A kA A kA A kA A
Size S00
3RV1011 0.16 ... 0.4 100 -- 100 -- 100 -- 100 -- 100 --
0.5 100 -- 100 -- 100 -- 100 -- 0.5 4
0.63 100 -- 100 -- 6 6 6 6 0.5 6
0.8 100 -- 100 -- 5 6 5 6 0.5 6
1 100 -- 4 10 2 10 2 10 0.5 10
1.25 100 -- 2 20 2 16 2 16 0.5 16
1.6 100 -- 2 20 2 20 2 20 1 16
2 100 -- 2 35 2 25 2 25 1 20
2.5 100 -- 2 35 2 25 2 25 1 25
3.2 100 -- 2 40 2 35 2 35 1 25
4 100 -- 2 40 2 35 2 35 1 35
5 100 -- 2 50 2 35 2 35 1 35
6.3 100 -- 2 50 2 40 2 40 1 40
8 50 80 2 63 2 40 2 40 1 40

7
10 50 80 2 63 2 50 2 50 1 50
12 50 80 2 80 2 50 2 50 1 50
3RV2.11 0.16 ... 0.4 100 -- 100 -- 100 -- 100 -- 100 --
0.5 100 -- 100 -- 100 -- 100 -- 0.5 4
0.63; 0.8 100 -- 100 -- 100 -- 100 -- 0.5 6
1 100 -- 100 -- 2 10 2 10 1.5 10
1.25 100 -- 100 -- 2 16 2 16 1.5 16
1.6 100 -- 100 -- 2 20 2 20 1.5 16
2; 2.5 100 -- 8 25 2 25 2 25 1.5 20
3.2 100 -- 8 32 2 32 2 32 1.5 25
4; 5 100 -- 4 32 1.5 32 1.5 32 1.5 25
6.3; 8 100 -- 4 50 1 40 1 40 1 35
10 100 -- 4 50 1 40 1 40 1 40
12.5 100 -- 4 63 1 50 1 50 1 40
16 55 80 4 63 1 50 1 50 1 40
Size S0
3RV2.21 0.16 ... 0.4 100 -- 100 -- 100 -- 100 -- 100 --
0.5 100 -- 100 -- 100 -- 100 -- 0.5 4
0.63; 0.8 100 -- 100 -- 100 -- 100 -- 0.5 6
1 100 -- 100 -- 2 10 2 10 1.5 10
1.25 100 -- 100 -- 2 16 2 16 1.5 16
1.6 100 -- 100 -- 2 20 2 20 1.5 16
2; 2.5 100 -- 8 25 2 25 2 25 1.5 20
3.2 100 -- 8 32 2 32 2 32 1.5 25
4; 5 100 -- 4 32 1.5 32 1.5 32 1.5 25
6.3; 8 100 -- 4 50 1 40 1 40 1 35
10 100 -- 4 50 1 40 1 40 1 40
12.5 100 -- 4 63 1 50 1 50 1 40
16 55 80 4 63 1 50 1 50 1 40
20 ... 25 55 80 4 63 1 50 1 50 1 50
28; 32 55 80 2 63 1 63 1 63 1 63
36; 40 20 80 2 63 1 63 1 63 1 63
-- No back-up fuse required, since short-circuit-proof up to 100 kA 3) Overvoltage category II applies for applications in IT systems > 600 V.
1) 5% overvoltage. 4) Back-up fuse only required if short-circuit current at installation location is
2)
Without overvoltage. > IcuIT.
5)
Alternatively, fuseless limiter combinations for 690 V AC can also be used.

Siemens IC 10 · 2023 7/11


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

Motor starter Rated current In Up to 240 V AC1) Up to Up to Up to Up to


protectors/ 400 V AC1)/415 V AC2) 440 V AC1)/460 V AC2) 500 V AC1)/525 V AC2) 690 V AC1)3)
circuit breakers IcuIT Max. fuse IcuIT Max. fuse IcuIT Max. fuse IcuIT Max. fuse IcuIT Max. fuse
(gG)4) (gG)4)5) (gG)4) (gG)4) (gG)4)
Type A kA A kA A kA A kA A kA A
Size S2
3RV2031, 3RV2131, 14 ... 25 100 -- 8 100 6 80 6 80 4 63
3RV2331 32 ... 45 100 -- 6 125 4 100 4 100 3 80
52 ... 80 100 -- 4 160 3 125 3 125 2 100
Size S2, with increased
switching capacity
3RV2032, 3RV2332 14 ... 25 100 -- 8 100 6 80 6 80 4 63
32 ... 45 100 -- 6 125 6 100 6 100 4 80
52 100 -- 6 160 6 125 6 125 4 100
59 ... 80 100 -- 6 160 4 125 4 125 4 100
Size S3
3RV2.41 40 65 125 10 63 5 50 5 50 5 50
50 65 125 8 80 3 63 3 63 3 63
63 65 160 6 80 3 63 3 63 3 63
75 65 160 5 100 2 80 2 80 2 80
84; 100 65 160 5 125 2 100 2 100 2 100
Size S3, with increased
switching capacity
3RV2.42 40 100 -- 12 80 6 63 6 63 6 63
50 100 -- 10 100 4 80 4 80 4 80
63 100 -- 7.5 100 4 80 4 80 4 80
75 100 -- 6 125 3 100 3 100 3 100
84; 100 100 -- 6 160 3 125 3 125 3 125
7

3)
-- No back-up fuse required, since short-circuit-proof up to 100 kA Overvoltage category II applies for applications in IT systems > 600 V.
1) 4)
10% overvoltage. Back-up fuse only required if short-circuit current at installation location is
2)
5% overvoltage. > IcuIT.
5)
Alternatively, fuseless limiter combinations for 690 V AC can also be used.

7/12 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data
Limiter function with standard devices for 500 V AC and 690 V AC according to IEC 60947-2
The table shows the rated ultimate short-circuit breaking With motor starter protector/circuit breaker assemblies, note the
capacity Icu and the rated service short-circuit breaking clearance to grounded parts and between the motor starter
capacity Ics with an upstream standard motor starter protectors/circuit breakers. Short-circuit-proof wiring between
protector/circuit breaker that fulfills the limiter function the motor starter protectors/circuit breakers must be ensured.
at voltages 500 V AC and 690 V AC. The motor starter protectors/circuit breakers can be mounted
side by side in a modular arrangement.
The short-circuit breaking capacity can be increased
significantly with an upstream standard motor starter
protector/circuit breaker with limiter function. The motor
starter protector/circuit breaker which is connected downstream
must be set to the rated current of the load.

Standard motor starter protectors/circuit breakers Rated current In Up to 500 V AC1)/525 V AC2) Up to 690 V AC1)3)
With limiter
Rated current In Icu Ics Icu Ics
Type Type A kA kA kA kA
Size S00
Size S0: 3RV2011 2 ... 6.3 -- -- 50 25
3RV2321-4EC10 8 100 50 50 25
In = 32 A 10 ... 16 100 50 204) 104)
Size S2: 3RV2011 10 ... 16 -- -- 50 25
3RV2331-4WC10
In = 52 A
Size S0
Size S0: 3RV2021 12 ... 32 100 50 204) 104)
3RV2321-4EC10

7
In = 32 A
Size S2: 3RV2021 16 ... 32 -- -- 50 20
3RV2331-4WC10
In = 52 A
Size S2, with increased switching capacity
Size S2: 3RV2032 14 ... 80 100 50 70 35
3RV2332-4RC10
In = 80 A
Size S3, with increased switching capacity
Size S35): 3RV2042 40 ... 100 100 50 50 25
3RV2342-4MC10
In = 100 A
-- No limiter required 3) Use 3RV29.8-1K phase barriers on the infeed side
1) 10% overvoltage. 4) Infeed to the limiter is always on the side 1L1/3L2/5L3.
2) 5)
5% overvoltage. Infeed to the limiter only on the side 2T1/4T2/6T3. Use 3RV2948-1K phase
barriers on the infeed side.

Siemens IC 10 · 2023 7/13


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data
Permissible rated data of devices approved for North America (UL/CSA)
Motor starter protectors of the 3RV2 series are approved These motor starter protectors/circuit breakers can be used as
for UL/CSA, and according to UL 508/UL 60947-4-1 and "Manual Motor Controllers" for "Group Installations", as "Manual
CSA C22.2 No. 14/CSA C22.2 No. 60947-4-1 they can be used Motor Controllers Suitable for Tap Conductor Protection in Group
on their own or as load feeders in combination with a contactor. Installations" and as "Self-Protected Combination Motor
Controllers (Type E)".

3RV motor starter protectors as "Manual Motor Controllers"


If used as a "Manual Motor Controller", the motor starter protector The file numbers for the approval of the 3RV as a manual motor
is always operated in combination with an upstream short-circuit controller are as follows:
protection. Approved fuses or circuit breakers according to • UL File No. 47705, CCN: NLRV
UL 489/CSA C22.2 No. 5 may be used for this purpose.
These devices must be dimensioned according to the National • CSA Master Contract 165071, Product Class: 3211
Electrical Code (UL) or Canadian Electrical Code (CSA).
Motor starter hp rating1) for FLA2) Rated current 240 V AC 480 V AC 600 V AC
protectors/ max. In UL CSA UL CSA UL CSA
circuit breakers
Ibc3) Ibc3) Ibc3) Ibc3) Ibc3) Ibc3)
Type V 1-phase 3-phase A kA kA kA kA kA kA
Size S00
3RV1011 0.16 ... 2 65 65 65 65 10 10
2.5 65 65 65 65 10 10
FLA2) max. 12 A, 115 1/2 -- 3.2 65 65 65 65 10 10
600 V 200 1 1/2 3 4 65 65 65 65 10 10
230 2 3 5 65 65 65 65 10 10
460 -- 7 1/2 6.3 65 65 65 65 10 10
575/600 -- 10
8 65 65 65 65 10 10
7

10 65 65 65 65 10 10
12 65 65 65 65 10 10
3RV2011, 3RV2111, 3RV2311, 3RV2411 0.16 ... 12.5 65 65 65 65 30 30
16 65 65 65 65 -- --
FLA2) max. 115/120 1 2
16 A, 480 V 200/208 2 3
12.5 A, 600 V 230/240 2 5
460/480 -- 10
575/600 -- 10
3RV1611-0BD10 0.2 65 65 65 65 10 10
Size S0
3RV2021, 3RV2121, 3RV2321, 3RV2421 0.16 ... 12.5 65 65 65 65 30 30
16 ... 25 65 65 65 65 --/(30)4) --/(30)4)
FLA2) max. 115/120 3 5 28, 32 65 65 50 50 -- --
40 A, 480 V 200/208 5 10 36, 40 65 65 12 12 -- --
12.5 A, 600 V 230/240 7 1/2 10
460/480 -- 30
575/600 -- --
Size S2
3RV2031, 3RV2131, 3RV2331, 3RV2431 14 ... 36 65 65 65 65 25 25
40 ... 52 65 65 65 65 22 22
FLA2) max. 115/120 7 1/2 10 59 ... 65 65 65 655) 655) 205) 205)
80 A, 600 V 200/208 15 25 73 ... 80 65 65 655) 655) 205) 205)
230/240 15 30
460/480 -- 60
575/600 -- 75
Size S2, with increased switching capacity
3RV2032, 3RV2332 14 ... 36 100 100 100 100 25 25
40 ... 52 100 100 100 100 22 22
FLA2) max. 115/120 7 1/2 10 59 ... 65 100 100 1005) 1005) 255) 255)
80 A, 600 V 200/208 15 25 73 ... 80 100 100 1005) 1005) 255) 255)
230/240 15 30
460/480 -- 60
575/600 -- 75
Size S3
3RV2041, 3RV2142, 3RV2341, 3RV2042, 3RV2342 40 ... 75 65 65 65 65 30 30
84 ... 100 65 65 65 65 10/306) 10/306)
2)
FLA max. 115/120 7 1/2 15
100 A, 600 V 200/208 15 30
230/240 20 40
460/480 -- 75
575/600 -- 100
4)
-- No approval Values in brackets only apply to 3RV2.23 motor starter protectors.
1) 5)
hp rating = Power rating in horse power (maximum motor rating). With Class J fuse.
2) 6) With Class J fuse 300 A.
FLA = Full Load Amps (motor full load current).
3) Corresponds to "short-circuit breaking capacity" according to UL/CSA.

7/14 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data
3RV20 motor starter protectors (up to 100 A) as "Manual Motor Controllers Suitable for Tap Conductor Protection in Group Installations"
The application as "Manual Motor Controllers Suitable for The 3RV20 motor starter protectors are approved as "Manual
Tap Conductor Protection in Group Installations" is only Motor Controllers Suitable for Tap Conductor Protection in Group
available for UL. CSA does not recognize this approval! When Installations" under the following file number:
the motor starter protector is used as a "Manual Motor Controller • UL File No. 47705, CCN: NLRV
Suitable for Tap Conductor Protection in Group Installations",
it must always be combined with upstream short-circuit
protection. Approved fuses or circuit breakers according to
UL 489 may be used for this purpose.
These devices must be dimensioned according to the
National Electrical Code.

Motor starter hp rating1) for FLA2) Rated current 240 V AC 480 Y/277 V AC 600 Y/347 V AC
protectors/ max. In UL UL UL
circuit breakers
3)
Ibc Ibc3) Ibc3)
Type V 1-phase 3-phase A kA kA kA
Size S00
3RV1011 0.16 ... 0.8 65 65 10
1 65 65 10
FLA2) max. 8 A, 115 1/3 -- 1.25 65 65 10
480 V 200 3/4 2 2 65 65 10
230 1 2 2.5 65 65 10
460 -- 5 3.2 65 65 10
575/600 -- --
4 65 65 10
5 65 65 10
6.3 65 65 10
8 65 65 10
3RV2011 0.16 ... 12.5 65 65 30

7
16 65 65 --
2)
FLA max. 115/120 1 2
16 A, 480 V 200/208 2 3
12.5 A, 600 V 230/240 2 5
460/480 -- 10
575/600 -- 10
Size S0
3RV2021 0.16 ... 12.5 65 65 30
16 ... 25 65 65 --
FLA2) max. 115/120 2 5 28; 32 50 50 --
32 A, 480 V 200/208 3 10
12.5 A, 600 V 230/240 5 10
460/480 -- 20
575/600 -- --
Size S2
3RV2031 14 ... 36 65 65 25
40 ... 52 65 65 22
FLA2) max. 115/120 7 1/2 10 59 ... 65 65 30 --
80 A, 480 V 200/208 15 25 73 65 20 --
52 A, 600 V 230/240 15 30 80 65 10 --
460/480 -- 60
575/600 -- 75
Size S2, with increased switching capacity
3RV2032 14 ... 36 100 100 25
40 ... 52 100 100 22
FLA2) max. 115/120 7 1/2 10 59 ... 65 100 42 --
80 A, 480 V 200/208 15 25 73 100 30 --
52 A, 600 V 230/240 15 30 80 100 10 --
460/480 -- 60
575/600 -- 75
Size S3
3RV2041, 3RV2042 40 ... 75 65 65 30
84 ... 100 65 65 --
2)
FLA max. 115/120 7 1/2 15
100 A, 480 V 200/208 15 30
75 A, 600 V 230/240 20 40
460/480 -- 75
575/600 -- 75
2)
-- No approval FLA = Full Load Amps (motor full load current).
1) 3)
hp rating = Power rating in horse power (maximum motor rating). Corresponds to "short-circuit breaking capacity" according to UL.

Siemens IC 10 · 2023 7/15


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data
3RV20 motor starter protectors (up to 100 A) as "Self-Protected Combination Motor Controllers (Type E)"
UL 508/UL 60947-4-1 approval demands 1-inch clearance omitted when the device is used as a "Self-Protected
and 2-inch creepage distance at line side for "Self-Protected Combination Motor Controller".
Combination Motor Controllers".
The 3RV20 motor starter protectors are approved as
Therefore, 3RV20 motor starter protectors of sizes S00 to S3 are "Self-Protected Combination Motor Controllers" under the
approved according to UL 508/UL 60947-4-1 in combination following file numbers:
with the terminal blocks listed below. • UL File No. E156943, CCN: NKJH
CSA does not require these extended clearance and creepage • CSA Master Contract 165071, Product Class: 3211 08
distances. According to CSA, these terminal blocks can be

Motor starter hp rating1) for FLA2) Rated current Up to 240 V AC Up to 480 Y/277 V AC Up to 600 Y/347 V AC
protectors/ max. In UL CSA UL CSA UL CSA
circuit breakers
3)
Ibc Ibc3) Ibc 3)
Ibc3) Ibc 3)
Ibc3)
Type V 1-phase 3-phase A kA kA kA kA kA kA
Size S00
3RV2011 + 3RV2928-1H4)5) 0.16 ... 12.5 65 65 65 65 30 30
16 65 65 65 65 -- --
FLA2) max. 115/120 1 2
16 A, 480 V; 200/208 2 3
12.5 A, 600 V 230/240 2 5
460/480 -- 10
575/600 -- 10
Size S0
3RV2021 + 3RV2928-1H4)5) 0.16 ... 12.5 65 65 65 65 30 30
16 ... 25 65 65 65 65 -- --
FLA2) max. 115/120 2 5 28; 32 50 50 50 50 -- --
32 A, 480 V 200/208 3 10
7

12.5 A, 600 V 230/240 5 10


460/480 -- 20
575/600 -- --
Size S2
3RV2031+ 3RV2938-1K4) 14 ... 36 65 65 65 65 25 25
40 ... 52 65 65 65 65 22 22
2)
FLA max. 115/120 7 1/2 10 59 ... 73 65 65 20 20 -- --
73 A, 480 V 200/208 15 25
52 A, 600 V 230/240 15 30
460/480 -- 60
575/600 -- 75
Size S2, with increased switching capacity
3RV2032 + 3RV2938-1K4) 14 ... 36 100 100 100 100 25 25
40 ... 52 100 100 100 100 22 22
FLA2) max. 115/120 7 1/2 10 59 ... 73 100 100 30 30 -- --
73 A, 480 V 200/208 15 25
52 A, 600 V 230/240 15 30
460/480 -- 60
575/600 -- 75
Size S3
3RV2041/3RV2042 + 3RT2946-4GA074) 40 ... 75 65 65 65 65 30 30
84 ... 100 65 65 65 65 -- --
FLA2) max. 115/120 7 1/2 15
100 A, 480 V 200/208 15 30
75 A, 600 V 230/240 20 40
460/480 -- 75
575/600 -- 75
-- No approval 3) Corresponds to "short-circuit breaking capacity" according to UL/CSA.
1) 4)
hp rating = Power rating in horse power (maximum motor rating). Not required for CSA.
2) 5)
FLA = Full Load Amps (motor full load current). Alternatively 3RV2928-1K phase barrier can be used.

7/16 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data
3RV27 and 3RV28 motor starter protectors as "circuit breakers"
These motor starter protectors are approved as circuit breakers 3RV27 and 3RV28 motor starter protectors are approved as
according to UL 489 and CSA 22.2 No. 5. They can be used "circuit breakers" under the following file numbers:
therefore as upstream short-circuit protective devices for • UL File No. E235044, CCN: DIVQ
"Manual Motor Controllers" and "Manual Motor Controllers
Suitable for Tap Conductor Protection in Group Installations". • CSA Master Contract 165071, Product Class: 1432 01

Motor starter Rated current In 240 V AC 480 Y/277 V AC 480 V AC 600 Y/347 V AC 600 V AC
protectors/ UL CSA UL CSA UL CSA UL CSA UL CSA
circuit breakers
Ibc1) Ibc1) Ibc1) Ibc1) Ibc1) Ibc1) Ibc1) Ibc1) Ibc1) Ibc1)
Type A kA kA kA kA kA kA kA kA kA kA
Size S00
3RV2711 0.16 ... 12.5 65 65 65 65 -- -- 10 10 -- --
15 65 65 65 65 -- -- -- -- -- --
3RV2811 0.16 ... 12.5 65 65 65 65 -- -- 10 10 -- --
15 65 65 65 65 -- -- -- -- -- --
Size S0
3RV2721 20; 22 50 50 50 50 -- -- -- -- -- --
3RV2821 20; 22 50 50 50 50 -- -- -- -- -- --
Size S3
3RV2742 10; 15 65 65 65 65 65 65 20 20 20 20
20 ... 30 65 65 65 65 65 65 20 20 -- --
35 ... 60 65 65 65 65 -- -- 20 20 -- --
70 65 65 65 65 -- -- 10 10 -- --
-- No approval 1) Corresponds to "short-circuit breaking capacity" according to UL.

Siemens IC 10 · 2023 7/17


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

General data
Type 3RV2.1. 3RV2.2. 3RV2.3. 3RV2.4. 3RV27, 3RV28
Size S00 S0 S2 S3 S00, S0

H
Dimensions (W x H x D)
• Screw terminals mm 45 x 97 x 92 45 x 97 x 92 55 x 140 x 149 70 x 165 x 169 45 x 144 x 92

D
W
• Spring-loaded terminals mm 45 x 106 x 92 45 x 119 x 92 -- -- --
Standards
• IEC 60947-1 (VDE 0660 Part 100) Yes
• IEC 60947-2 (VDE 0660 Part 101) Yes
• IEC 60947-4-1 (VDE 0660 Part 102) Yes
• UL 508/UL 60947-4-1, Yes (not for 3RV2...-.....-0BA0 and -0DA0 motor starter protectors) --
CSA C22.2 No. 14/CSA C22.2 No. 60947-4-1
• UL 489, CSA C22.2 No. 5 -- Yes
Number of poles 3
Max. rated current In max A 16 40 80 100 22
(= max. rated operational current Ie)
Permissible ambient temperature
• Storage/transport °C -50 ... +80
• Operation In: 0.16 ... 32 A °C -20 (-50)1) ... +70 --
(current reduction above +60 °C)
In: 36 ... 40 A °C -- -20 ... +40 --
(the devices must
not be mounted
side-by-side and
they must not be
assembled with
link modules with
contactors.
A lateral clearance
of 9 mm is
required.)
7

In: 14 ... 80 A °C -- -20 (-50)1) ... +70 --


(current reduction
above +60 °C)
In: 40 ... 100 A °C -- -20 ... +70 --
(current reduction
above +60 °C)
Permissible rated current at inside temperature of
control cabinet
• +60 °C % 100
• +70 °C % 87
Permissible rated current at ambient temperature of
enclosure (applies to motor starter protector/circuit
breaker inside enclosure: S00/S0  32 A, S2  52 A)
• +35 °C % 100 --
• +60 °C % --
Rated operational voltage Ue
• According to IEC V AC 690 (when a molded-plastic enclosure is used only 500 V)
• According to UL/CSA V AC 600
Rated frequency Hz 50/60
Rated insulation voltage Ui V 690 1 000 690
Rated impulse withstand voltage Uimp kV 6 8 6
Utilization category
• IEC 60947-2 (motor starter protector/circuit breaker) A
• IEC 60947-4-1 (motor starter) AC-3 and AC-3e
Trip class CLASS According to 10 10/20 --
IEC 60947-4-1
Power loss Pv per motor starter In: 0.16 ... 0.63 A W 5.5 -- 5.5
protector In: 0.8 ... 6.3 A W 7.3 -- 7.3
dependent upon In: 8 ... 16 A W 9.3 -- 9.3
rated current In In: 14 ... 16 A W -- 9.3 12.5 -- 9.3
(upper setting range) In: 17 ... 25 A W -- 10.5 14.5 -- 10.5
In: 28 ... 32 A W -- 13.3 18 --
P
R per conducting path = -------------- In: 36 ... 40 A W -- 16.3 20 --
 2 3 In: 45 ... 52 A W -- 24.5 --
In: 59 ... 65 A W -- 26 --
In: 73 ... 80 A W -- 29.5 --
In: 40 ... 50 A W -- 27 --
In: 63 ... 75 A W -- 38 --
In: 84 ... 93 A W -- 39 --
In: 100 A W -- 44 --
Shock resistance According to g/ms 25/11 (square and sine pulse)
IEC 60068-2-27
1) Value in brackets applies to the 3RV2...-.....-0BA0 motor starter protectors.

7/18 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

General data (continued)


Type 3RV2.1. 3RV2.2. 3RV2.3. 3RV2.4. 3RV27, 3RV28
Size S00 S0 S2 S3 S00, S0

H
Dimensions (W x H x D)
• Screw terminals mm 45 x 97 x 92 45 x 97 x 92 55 x 140 x 149 70 x 165 x 169 45 x 144 x 92

D
W
• Spring-loaded terminals mm 45 x 106 x 92 45 x 119 x 92 -- -- --
Degree of protection IP on the front according to IEC 60529 IP20 (screw terminals and spring-loaded terminals)
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching from the front (screw and spring-loaded terminals)
Temperature compensation According to IEC 60947-4-1 °C -20 ... +60
Phase failure sensitivity According to IEC 60947-4-1 Yes (not for 3RV23, 3RV2...-.....-0DA0 motor starter protectors) No
Protection of motors in hazardous environments Yes (only for 3RV20 motor starter protectors, No
not for 3RV20..-.....-0BA0 and -0DA0)
• EC type-examination certificate number according to DMT 02 ATEX F 001 II (2) GD No
European Directive 2014/34/EU (ATEX)
• According to international standard IECEx IECEx BVS14.0102 [Ex] No
Isolating function According to IEC 60947-2 Yes
Main and EMERGENCY STOP According to IEC 60204-1 Yes
switch characteristics (VDE 0113)
(with corresponding accessories)
Protective separation between According to IEC 60947-1
main and auxiliary circuits
required for PELV applications
• Up to 400 V + 10% Yes
• Up to 415 V + 5% (higher voltages on request) Yes
• Up to 690 V (depends on mounted accessories) Yes, see certificate
Permissible mounting position Any, according to IEC 60447 start command "I" right-hand side or top
Mechanical endurance (operating cycles)
• 3RV2 100 000 Up to 52 A: 25 000 100 000

7
50 000, up to
80 A: 20 000
• 3RV2...-.....-0BA0 500 250 --
Electrical endurance (operating cycles)
• 3RV2 100 000 Up to 52 A: 25 000 100 000
50 000, up to
80 A: 20 000
• 3RV2...-.....-0BA0 500 250 --
Max. switching frequency per hour (motor starts) 1/h 15

General data
Type 3RV2742 3RV1611-0BD101) 3RV1011
Size S3 S00 S00
H

Dimensions (W x H x D) mm 70 x 168 x 169 45 x 90 x 70 45 x 90 x 70


D

Standards
• IEC 60947-1 (VDE 0660 Part 100) Yes
• IEC 60947-2 (VDE 0660 Part 101) Yes
• UL 508/UL 60947-4-1, CSA C22.2 No.14/CSA 60947-4-1 No Yes
• UL 489, CSA C22.2 No. 5 Yes No
Number of poles 3
Max. rated current In max A 70 0.2 12
(= max. rated operational current Ie)
Permissible ambient temperature
• Storage/transport °C -50 ... +80
• Operation °C -20 ... +70 (current reduction above +60 °C)
Permissible rated current at inside temperature of control cabinet
• +60 °C % 100
• +70 °C % 87
Permissible rated current at ambient temperature
of enclosure (applies to motor starter protector/
circuit breaker inside enclosure)
• +35 °C % -- 100
• +60 °C % --
Rated operational voltage Ue
• According to IEC V AC 690 (with molded-plastic enclosure 500 V)
• According to UL/CSA V AC 600
Rated frequency Hz 50/60
Rated insulation voltage Ui V 1 000 690
Rated impulse withstand voltage Uimp kV 8 6
Utilization category
• IEC 60947-2 (motor starter protector/circuit breaker) A
• IEC 60947-4-1 (motor starter) AC-3 AC-3 and AC-3e
1)
"Technical specifications" for 3RV1611 voltage transformer circuit breakers,
see page 7/24.

Siemens IC 10 · 2023 7/19


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

General data (continued)


Type 3RV2742 3RV1611-0BD101) 3RV1011
Size S3 S00 S00

H
Dimensions (W x H x D) mm 70 x 168 x 169 45 x 90 x 70 45 x 90 x 70

D
W

Power loss Pv per motor starter In: 0.2 A W -- 5 --


protector In: 10 A W 10 --
dependent upon In: 15 ... 35 A W 14 --
rated current In In: 40 ... 70 A W 23.5 --
(upper setting range)
In: ... 1.25 A W -- 5.5
P
R per conducting path = --------------- In: 1.65 ... 6.3 A W -- 7.3
 2 3 In: 8 ... 12 A W -- 9.3

Shock resistance According to g/ms 25/11 (square and sine pulse)


IEC 60068-2-27
Degree of protection IP on according to IP20
the front IEC 60529
Touch protection on the front according to Finger-safe for vertical touching from the front
IEC 60529
Temperature compensation According to °C -20 ... +60
IEC 60947-4-1
Phase failure sensitivity According to No Yes
IEC 60947-4-1
Explosion protection – Safe operation of motors with No Yes
"increased safety" type of protection
EC type-examination certificate number
according to Directive 2014/34/EU (ATEX)
Isolating function According to Yes
7

IEC 60947-2
Main and EMERGENCY STOP According to Yes
switch characteristics IEC 60204-1
(with corresponding accessories) (VDE 0113)
Protective separation between According to
main and auxiliary circuits, IEC 60947-1
required for PELV applications
• Up to 400 V + 10% Yes
• Up to 415 V + 5% (higher voltages on request) Yes
Permissible mounting position Any, according to IEC 60447 start command "I" right-hand side or top
Mechanical endurance Operat- 25 000 100 000
ing cy-
cles
Electrical endurance Operat- 25 000 100 000
ing cy-
cles
Max. switching frequency per hour (motor starts) 1/h 15
1)
"Technical specifications" for 3RV1611 voltage transformer circuit breakers,
see page 7/24.

Rated data of the auxiliary switches and


signaling switches
Lateral auxiliary Signaling switch Transverse
switch with auxiliary switch with
1 NO + 1 NC, 2 NO, 1 CO 1 NO + 1 NC, 2 NO
2 NC, 2 NO + 2 NC
Max. rated voltage
• According to NEMA (UL) V AC 600 250
• According to NEMA (CSA) V AC 600 250
Uninterrupted current A 10 5 2.5
Switching capacity 1 NO + 1 NC, A600, Q300 B600, R300 C300, R300
2 NO, 2 NC:
A600, Q300;
2 NO + 2 NC:
A300, Q300

7/20 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

Front transverse auxiliary switches


Switching capacity for different voltages
1 CO 1 NO + 1 NC, 2 NO
Rated operational current Ie
• At AC-15, alternating voltage
- 24 V A 4 2
- 230 V A 3 0.5
• At AC-12 = Ith, alternating voltage
- 24 V A 10 2.5
- 230 V A 10 2.5
• At DC-13, direct voltage L/R 200 ms
- 24 V A 1 1
- 48 V A -- 0.3
- 60 V A -- 0.15
- 110 V A 0.22 --
- 220 V A 0.1 --
Minimum load capacity V 17
mA 1

Front transverse solid-state compatible auxiliary switches


Switching capacity for different voltages
1 CO
Rated operational voltage Ue Alternating voltage V 125
Rated operational current Ie/AC-14 at Ue = 125 V A 0.1
Rated operational voltage Ue Direct voltage L/R 200 ms V 60
Rated operational current Ie/DC-13 at Ue = 60 V A 0.3

7
Minimum load capacity V 5
mA 1

Lateral auxiliary switches with signaling switch


Switching capacity for different voltages:
Lateral auxiliary switch with 1 NO + 1 NC, 2 NO, 2 NC, 2 NO + 2 NC,
Signaling switch
Rated operational current Ie
• At AC-15, alternating voltage
- 24 V A 6
- 230 V A 4
- 400 V A 3
- 690 V A 1
• At AC-12 = Ith, alternating voltage
- 24 V A 10
- 230 V A 10
- 400 V A 10
- 690 V A 10
• At DC-13, direct voltage L/R 200 ms
- 24 V A 2
- 110 V A 0.5
- 220 V A 0.25
- 440 V A 0.1
Minimum load capacity V 17
mA 1

Auxiliary releases
Undervoltage releases Shunt releases
Power consumption
• During pick-up
- AC voltages VA/W 20.2/13
- DC voltages W 20 13 ... 80
• During uninterrupted duty
- AC voltages VA/W 7.2/2.4 --
- DC voltages W 2.1 --
Response voltage
• Tripping V 0.35 ... 0.7 x Us 0.7 ... 1.1 x Us
• Pick-up V 0.85 ... 1.1 x Us --
Opening time maximum ms 20

Short-circuit protection for auxiliary and control circuits


Melting fuses operational class gG A 10
Miniature circuit breakers C characteristic A 6 (prospective short-circuit current < 0.4 kA)

Siemens IC 10 · 2023 7/21


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

Conductor cross-sections of main circuit


Type 3RV2.11 3RV2.21 3RV2.31-4B.1., 3RV2.31-4J.1., 3RV27.1,
3RV2.31-4D.1., 3RV2.31-4K.1., 3RV28.1
3RV2.31-4E.1., 3RV2.31-4R.1.,
3RV2.31-4P.1., 3RV2.31-4W.1.,
3RV2.31-4S.1., 3RV2.31-4X.1.,
3RV2.31-4T.1., 3RV2431-4VA1.,
3RV2.31-4U.1., 3RV2.32
3RV2.31-4V.1.
Size S00 S0 S2 S00, S0
Connection type Screw terminals

Terminal screw M3, M4, M6, M4,


Pozidriv size 2 Pozidriv size 2 Pozidriv size 2 Pozidriv size 2
Operating devices mm  5 ... 6  5 ... 6  5 ... 6  5 ... 6
Prescribed tightening torque Nm 0.8 ... 1.2 2 ... 2.5 3.0 ... 4.5 2.5 ... 3
Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 2 x (0.75 ... 2.5)1), 2 x (1 ... 2.5)1), 2 x (1 ... 25)1), 2 x (1 ... 35)1), 2 x (1 ... 10)1),
2x4 2 x (2.5 ... 10)1) 1 x (1 ... 35)1) 1 x (1 ... 50)1) max. 1 x 25
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)1), 2 x (1 ... 2.5)1), 2 x (1 ... 16)1), 2 x (1 ... 25)1), 1 x (1 ... 16),
2 x (0.75 ... 2.5)1) 2 x (2.5 ... 6)1), 1 x (1 ... 25)1) 1 x (1 ... 35)1) max. 6 + 16
1 x 10
• AWG cables, solid or stranded AWG 2 x (20 ... 16)1), 2 x (16 ... 12)1), 2 x (18 ... 3)1), 2 x (18 ... 2)1), 2 x (14 ... 10)
2 x (18 ... 12)1) 2 x (14 ... 8)1) 1 x (18 ... 2)1) 1 x (18 ... 1)1)
Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5


7

Conductor cross-sections (min./max.),


one or two conductors can be connected
• Solid or stranded mm2 2 x (0.5 ... 4) 2 x (1 ... 10) --
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5) 2 x (1 ... 6) --
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 2.5) 2 x (1 ... 6) --
• AWG cables, solid or stranded AWG 2 x (20 ... 12) 2 x (18 ... 8) --
Max. external diameter of the conductor insulation mm 3.6 6.4 --
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must be in the range specified.

7/22 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

Conductor cross-sections of main circuit (continued)


Type 3RV2.4./ 3RV1611-0BD101)/
3RV2742 3RV1011
Size S3 S00
Connection type Screw terminals Screw terminals
with box terminal
Terminal screw M6 Pozidriv size 2
Prescribed tightening torque Nm 4.5 ... 6 0.8 .... 1.2
Conductor cross-sections (min./max.), one or two conductors can be
connected
• Solid or stranded mm2 2 x (2.5 ... 16)2), 2 x (0.5 ... 1.5)2),
2 x (10 ... 50)2), 2 x (0.75 ... 2.5)2)
1 x (10 ... 70)2)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (2.5 ... 35)2), 2 x (0.5 ... 1.5)2),
1 x (2.5 ... 50)2) 2 x (0.75 ... 2.5)2)
• AWG cables, solid or stranded AWG 2 x (10 ... 1/0)2), 2 x (18 ... 14)
1 x (10 ... 2/0)2)
Ribbon cable conductors (number x width x thickness) mm 2 x (6 x 9 x 0.8) --
Removable box terminals3)
• With copper bars4) mm 2 x 12 x 4 --
• With cable lugs5)
- Terminal screw M6
- Prescribed tightening torque Nm 4.5 ... 6
- Usable ring cable lugs d3 mm d2 = min. 6.3
d2 mm d3 = max. 19

7
I201_12740

1) 4)
"Technical specifications" for 3RV16 voltage transformer circuit breakers, If bars larger than 12 mm x 10 mm are connected, a 3RT2946-4EA2 cover
see page 7/24. is needed to maintain the required phase clearance, see page 7/59.
2) If two different conductor cross-sections are connected to one clamping 5) If conductors larger than 25 mm2 are connected, the 3RT2946-4EA2 cover
point, both cross-sections must be in the range specified. is needed to maintain the required phase clearance, see page 7/59.
3)
Cable lug and busbar connection possible after removing the box
terminals. This does not apply for 3RV2742.

Conductor cross-sections for auxiliary and control circuits1)


Type 3RV2.11 3RV1011/ 3RV2.21 3RV2.3 3RV2.4 3RV27,
3RV1611- 3RV28
0BD102)
Size S00 S0 S2 S3 S00, S0, S3
Connection type Screw terminals

Terminal screw M3, Pozidriv size 2


Operating devices mm  5 ... 6
Prescribed tightening torque Nm 0.8 ... 1.2
Conductor cross-sections (min./max.), one or two conductors can be
connected
• Solid or stranded mm2 2 x (0.5 ... 1.5)3), 2 x (0.75 ... 2.5)3)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)3), 2 x (0.75 ... 2.5)3)
• AWG cables, solid or stranded AWG 2 x (18 ... 14)3), 2 x (20 ... 16)3)
Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5


Conductor cross-sections (min./max.), one or two conductors can be
connected
• Solid or stranded mm2 2 x (0.5 ... 2.5)
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
Max. external diameter of the conductor insulation mm 3.6
1) 3)
The conductor cross-sections also apply to the 3RV2901-1. auxiliary If two different conductor cross-sections are connected to one clamping
switch, 3RV2921-1M signaling switch and 3RV29.2-1.... auxiliary release. point, both cross-sections must be in the range specified.
2)
"Technical specifications" for 3RV16 voltage transformer circuit breakers,
see page 7/24.

Siemens IC 10 · 2023 7/23


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data
Voltage transformer circuit breakers
General data
Type 3RV1611-1AG14 3RV1611-1CG14 3RV1611-1DG14
Size S00 S00 S00

H
Dimensions (W x H x D) mm 45 x 90 x 70 45 x 90 x 70 45 x 90 x 70

D
W

Rated current In A 1.4 2.5 3


Ambient temperature
• During storage/transport °C -50 ... +80
• During operation °C -20 ... +60 (up to +70 °C possible with current reduction)
Rated operational voltage Ue V 400
Rated frequency Hz 16.66 ... 60
Rated insulation voltage Ui V 690
Short-circuit breaking capacity Icu at 400 V AC kA 50
Set value of the thermal overload release A 1.4 2.5 3
Response value of the instantaneous electronic release A 6 20% 10.5 20% 20 20%
Tripping time of the instantaneous electronic release ms Approx. 6 at 12 A Approx. 6 at 20 A Approx. 6 at 40 A
Internal resistance
• In cold state  > 0.25 6.5%
• In heated state  > 0.30 6.5%
Shock resistance according to IEC 60068-2-27 g/ms 15
Degree of protection IP on the front according to IEC 60529 IP20
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching from the front
7

Endurance
• Mechanical Oper- 10 000
ating
cycles
• Electrical Oper- 10 000
ating
cycles
Permissible mounting position Any

Type 3RV1611-1AG14 3RV1611-1CG14 3RV1611-1DG14


Conductor cross-sections, main circuit, 1 or 2 conductors
Connection type Screw terminals

Terminal screw Pozidriv size 2


Conductor cross-sections (min./max.), one or two conductors can be
connected
• Solid or stranded mm2 2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1), 2 x (1 ... 4)
2
• Finely stranded with end sleeve (DIN 46228) mm 2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1)
Auxiliary switches for blocking the distance protection
With defined lateral assignment for blocking distance protection 1 CO (for use as 1 NO or 1 NC)
Rated operational voltage Ue Alternating voltage V 125
Rated operational current Ie/AC-14 at Ue = 125 V A 0.1
Rated operational voltage Ue Direct voltage L/R 200 ms V 60
Rated operational current Ie/DC-13 at Ue = 60 V A 0.3
Minimum load capacity V 5
mA 1
Short-circuit protection for auxiliary circuit
Melting fuse A 250 V type FF 2A (prospective short-circuit current < 1.1 kA)
1) If two different conductor cross-sections are connected to one clamping
point, both cross-sections must be in the range specified.

7/24 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

Terminals for "Self-Protected Combination Motor Controllers (Type E)


according to UL 508/UL 60947-4-1"
Type 3RV2928-1H
Prescribed tightening torque Nm 2.5 ... 3
Conductor cross-sections
• Front clamping point connected
- Solid mm2 1 ... 10
- Finely stranded with end sleeve mm2 1 ... 16
NSB0_00479

- Stranded mm2 2.5 … 25


- AWG cables, solid or stranded AWG 14 ... 3
- Terminal screw M4
• Rear clamping point connected
- Solid mm2 1 ... 10
- Finely stranded with end sleeve mm2 1 ... 16
NSB0_00480

- Stranded mm2 1.5 ... 25


- AWG cables, solid or stranded AWG 14 ... 6
- Terminal screw M4
• Both clamping points connected
- Front clamping point:
Solid mm2 1 ... 10
NSB0_00481

Finely stranded with end sleeve mm2 1 ... 101), 1 ... 61)
Stranded mm2 2.5 ... 10
AWG cables, solid or stranded AWG 14 ... 6
Terminal screw M4
- Rear clamping point:
Solid mm2 1 ... 10
Finely stranded with end sleeve mm2 1 ... 101), 1 ... 161)
Stranded mm2 2.5 ... 10
AWG cables, solid or stranded AWG 16 ... 3
Terminal screw M4

7
1)
The following connections are possible when both clamping points are
connected:
- front 1 to 10 mm2 and rear 1 to 10 mm2,
- front 1 to 6 mm2 and rear 1 to 16 mm2.

Siemens IC 10 · 2023 7/25


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
General data

Connection module (plug and adapter) for motor starter


protectors/circuit breakers with screw terminals
Type 3RT1900-4RE01 3RT1926-4RD01
Motor feeder connector S0 Adapter S0
General data
Rated insulation voltage Ui V 690
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 6
(pollution degree 3)
Rated operational voltage Ue V 440
Rated frequency f Hz 50/60
For AC operation
Rated operational current Ie A 25
AC-3 and AC-3e at 400 V
Mechanical endurance Operat- 10 million
ing
cycles
Electrical endurance at Ie Operat- 1 million
ing
cycles
Protective separation according to IEC 60947-1 V 400
(pollution degree 3)
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -50 ... +80
Conductor cross-sections
Connection type Screw terminals
7

2
• Solid mm 1 x (0.5 ... 6)
• Finely stranded without/with end sleeve mm2 1 x (0.5 ... 6)
• Stranded mm2 1 x (0.5 ... 6)
• AWG cables, solid or stranded AWG 1 x (20 ... 10)
• Tightening torque Nm 0.6 ... 0.8
• Corresponding opening tool Cross-tip screwdriver PZ2
s and u rated data
Rated operational voltage Ue V 480
Rated insulation voltage Ui V 600
Uninterrupted current, at 40 °C A 25
Short-circuit protection1)
• At 600 V kA 5
• CLASS RK5 fuse A 100
• Circuit breakers A 100
with overload protection according to UL 489
Combination motor controllers type E according to UL 508
at 480 V Type 3RV202
A 22
kA 65
at 600 V Type 3RV202
A 22
kA 10
1)
For more information about short-circuit values, e.g. for protection against
high short-circuit currents, see the UL reports.

7/26 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
AC-3e E3 ready IE4 ready IE3/IE4 ready For motor protection

■ Selection and ordering data


CLASS 10, without auxiliary switches
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41E

3RV2011-..A10, 3RV2011-..A20,
3RV2011-..A10-0BA0 3RV2011-.AA20-0BA0

Rated Suitable for Setting range Instanta- Short-circuit Screw terminals Spring-loaded
current three-phase for thermal neous breaking capacity terminals
motors1) overload electronic at 400 V AC
with P release release
In Icu Article No. Price Article No. Price
per PU per PU
A kW A A kA
Size S00
0.16 0.04 0.11 ... 0.16 2.1 100 3RV2011-0AA10 3RV2011-0AA20
0.2 0.06 0.14 ... 0.2 2.6 100 3RV2011-0BA10 3RV2011-0BA20
0.25 0.06 0.18 ... 0.25 3.3 100 3RV2011-0CA10 3RV2011-0CA20

7
0.32 0.09 0.22 ... 0.32 4.2 100 3RV2011-0DA10 3RV2011-0DA20
0.4 0.09 0.28 ... 0.4 5.2 100 3RV2011-0EA10 3RV2011-0EA20
0.5 0.12 0.35 ... 0.5 6.5 100 3RV2011-0FA10 3RV2011-0FA20
0.63 0.18 0.45 ... 0.63 8.2 100 3RV2011-0GA10 3RV2011-0GA20
0.8 0.18 0.55 ... 0.8 10 100 3RV2011-0HA10 3RV2011-0HA20
1 0.25 0.7 ... 1 13 100 3RV2011-0JA10 3RV2011-0JA20
1.25 0.37 0.9 ... 1.25 16 100 3RV2011-0KA10 3RV2011-0KA20
1.6 0.55 1.1 ... 1.6 21 100 3RV2011-1AA10 3RV2011-1AA20
2 0.75 1.4 ... 2 26 100 3RV2011-1BA10 3RV2011-1BA20
2.5 0.75 1.8 ... 2.5 33 100 3RV2011-1CA10 3RV2011-1CA20
3.2 1.1 2.2 ... 3.2 42 100 3RV2011-1DA10 3RV2011-1DA20
4 1.5 2.8 ... 4 52 100 3RV2011-1EA10 3RV2011-1EA20
5 1.5 3.5 ... 5 65 100 3RV2011-1FA10 3RV2011-1FA20
6.3 2.2 4.5 ... 6.3 82 100 3RV2011-1GA10 3RV2011-1GA20
8 3 5.5 ... 8 104 100 3RV2011-1HA10 3RV2011-1HA20
10 4 7 ... 10 130 100 3RV2011-1JA10 3RV2011-1JA20
12.5 5.5 9 ... 12.5 163 100 3RV2011-1KA10 3RV2011-1KA20
16 7.5 10 ... 16 208 55 3RV2011-4AA10 3RV2011-4AA20
For special operating conditions down to -50 °C2)3)
1.25 0.37 0.9 ... 1.25 16 100 3RV2011-0KA10-0BA0 --
1.6 0.55 1.1 ... 1.6 21 100 3RV2011-1AA10-0BA0 3RV2011-1AA20-0BA0
2.5 0.75 1.8 ... 2.5 33 100 3RV2011-1CA10-0BA0 --
3.2 1.1 2.2 ... 3.2 42 100 3RV2011-1DA10-0BA0 --
4 1.5 2.8 ... 4 52 100 3RV2011-1EA10-0BA0 --
5 1.5 3.5 ... 5 65 100 3RV2011-1FA10-0BA0 --
6.3 2.2 4.5 ... 6.3 82 100 3RV2011-1GA10-0BA0 --
8 3 5.5 ... 8 104 100 3RV2011-1HA10-0BA0 --
10 4 7 ... 10 130 100 3RV2011-1JA10-0BA0 --
12.5 5.5 9 ... 12.5 163 100 3RV2011-1KA10-0BA0 --
16 7.5 10 ... 16 208 55 3RV2011-4AA10-0BA0 3RV2011-4AA20-0BA0
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Auxiliary switches and other accessories can be ordered
starting and rated data of the motor to be protected must be considered separately (see page 7/48 onwards).
when selecting the units.
2)
The 3RV2011-.....-0BA0 motor starter protectors have a mechanical
endurance of 500 operating cycles.
3) The motor starter protectors do not have UL/CSA approval and are not certified
either according to the European Explosion Protection Directive (ATEX) or
according to the International Explosion Protection Standard (IECEx).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/27
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For motor protection IE3 ready IE4 ready IE3/IE4 ready
AC-3e
CLASS 10, without auxiliary switches
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41E

3RV2021-..A10, 3RV2021-4.A10-0BA0 3RV2021-..A20, 3RV2021-..A20-0BA0

Rated Suitable for Setting range Instanta- Short-circuit Screw terminals Spring-loaded
current three-phase for thermal neous breaking capacity terminals
motors1) overload electronic at 400 V AC
with } release release
In Icu Article No. Price Article No. Price
per PU per PU
A kW A A kA
Size S0
0.16 0.04 0.11 ... 0.16 2.1 100 3RV2021-0AA10 --
0.2 0.06 0.14 ... 0.2 2.6 100 3RV2021-0BA10 --
0.25 0.06 0.18 ... 0.25 3.3 100 3RV2021-0CA10 --
0.32 0.09 0.22 ... 0.32 4.2 100 3RV2021-0DA10 --
0.4 0.09 0.28 ... 0.4 5.2 100 3RV2021-0EA10 --
0.5 0.12 0.35 ... 0.5 6.5 100 3RV2021-0FA10 --
7

0.63 0.18 0.45 ... 0.63 8.2 100 3RV2021-0GA10 3RV2021-0GA20


0.8 0.18 0.55 ... 0.8 10 100 3RV2021-0HA10 3RV2021-0HA20
1 0.25 0.7 ... 1 13 100 3RV2021-0JA10 3RV2021-0JA20
1.25 0.37 0.9 ... 1.25 16 100 3RV2021-0KA10 3RV2021-0KA20
1.6 0.55 1.1 ... 1.6 21 100 3RV2021-1AA10 3RV2021-1AA20
2 0.75 1.4 ... 2 26 100 3RV2021-1BA10 3RV2021-1BA20
2.5 0.75 1.8 ... 2.5 33 100 3RV2021-1CA10 3RV2021-1CA20
3.2 1.1 2.2 ... 3.2 42 100 3RV2021-1DA10 3RV2021-1DA20
4 1.5 2.8 ... 4 52 100 3RV2021-1EA10 3RV2021-1EA20
5 1.5 3.5 ... 5 65 100 3RV2021-1FA10 3RV2021-1FA20
6.3 2.2 4.5 ... 6.3 82 100 3RV2021-1GA10 3RV2021-1GA20
8 3 5.5 ... 8 104 100 3RV2021-1HA10 3RV2021-1HA20
10 4 7 ... 10 130 100 3RV2021-1JA10 3RV2021-1JA20
12.5 5.5 9 ... 12.5 163 100 3RV2021-1KA10 3RV2021-1KA20
16 7.5 10 ... 16 208 55 3RV2021-4AA10 3RV2021-4AA20
20 7.5 13 ... 20 260 55 3RV2021-4BA10 3RV2021-4BA20
22 11 16 ... 22 286 55 3RV2021-4CA10 3RV2021-4CA20
25 11 18 ... 25 325 55 3RV2021-4DA10 3RV2021-4DA20
28 15 23 ... 28 364 55 3RV2021-4NA10 3RV2021-4NA20
322) 15 27 ... 32 400 55 3RV2021-4EA10 3RV2021-4EA20
363) 18.5 30 ... 36 432 20 3RV2021-4PA10 --
403) 18.5 34 ... 40 480 20 3RV2021-4FA10 --
For special operating conditions down to -50 °C4)5)
1 0.25 0.7 ... 1 13 100 -- 3RV2021-0JA20-0BA0
1.6 0.55 1.1 ... 1.6 21 100 -- 3RV2021-1AA20-0BA0
2 0.75 1.4 ... 2 26 100 -- 3RV2021-1BA20-0BA0
2.5 0.75 1.8 ... 2.5 33 100 -- 3RV2021-1CA20-0BA0
4 1.5 2.8 ... 4 52 100 -- 3RV2021-1EA20-0BA0
6.3 2.2 4.5 ... 6.3 82 100 -- 3RV2021-1GA20-0BA0
8 3 5.5 ... 8 104 100 -- 3RV2021-1HA20-0BA0
10 4 7 ... 10 130 100 -- 3RV2021-1JA20-0BA0
12.5 5.5 9 ... 12.5 163 100 -- 3RV2021-1KA20-0BA0
16 7.5 10 ... 16 208 55 -- 3RV2021-4AA20-0BA0
20 7.5 13 ... 20 260 55 3RV2021-4BA10-0BA0 --
22 11 16 ... 22 286 55 3RV2021-4CA10-0BA0 --
25 11 18 ... 25 325 55 3RV2021-4DA10-0BA0 3RV2021-4DA20-0BA0
28 15 23 ... 28 364 55 -- 3RV2021-4NA20-0BA0
322) 15 27 ... 32 400 55 3RV2021-4EA10-0BA0 3RV2021-4EA20-0BA0
403) 18.5 34 ... 40 480 20 3RV2021-4FA10-0BA0 --
1) 4)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual The 3RV2021-.....-0BA0 motor starter protectors have a mechanical
starting and rated data of the motor to be protected must be considered endurance of 500 operating cycles.
when selecting the units. 5) The motor starter protectors do not have UL/CSA approval and are not certified
2) Suitable for use with IE3 and IE4 motors up to a starting current of 256 A. either according to the European Explosion Protection Directive (ATEX) or
For higher starting currents we recommend using 3RV2 motor starter according to the International Explosion Protection Standard (IECEx).
protectors size S2.
3) Auxiliary switches and other accessories can be ordered
The devices must not be mounted side-by-side and they must not be separately (see page 7/48 onwards).
assembled with link modules with contactors. A lateral clearance of 9 mm
is required. For use with IE3 and IE4 motors we recommend using 3RV2
motor starter protectors size S2.

* You can order this quantity or a multiple thereof.


7/28 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
AC-3e E3 ready IE4 ready IE3/IE4 ready For motor protection
CLASS 10, without auxiliary switches

3RV2031-4.A10, 3RV2032-4.A10
3RV2031-4.A10-0BA0

Rated Suitable for Setting range for Instantaneous Short-circuit Screw terminals PU PS* PG
current three-phase thermal overload electronic release breaking (UNIT,
motors1) release capacity at SET, M)
with P 400 V AC
In Icu Article No. Price
per PU
A kW A A kA
Size S2
14 5.5 9.5 ... 14 208 65 3RV2031-4SA10 1 1 unit 41E
17 7.5 12 ... 17 260 65 3RV2031-4TA10 1 1 unit 41E
20 7.5 14 ... 20 260 65 3RV2031-4BA10 1 1 unit 41E
25 11 18 ... 25 325 65 3RV2031-4DA10 1 1 unit 41E
32 15 22 ... 32 416 65 3RV2031-4EA10 1 1 unit 41E
36 18.5 28 ... 36 520 65 3RV2031-4PA10 1 1 unit 41E

7
40 18.5 32 ... 40 585 65 3RV2031-4UA10 1 1 unit 41E
45 22 35 ... 45 650 65 3RV2031-4VA10 1 1 unit 41E
52 22 42 ... 52 741 65 3RV2031-4WA10 1 1 unit 41E
59 30 49 ... 59 845 65 3RV2031-4XA10 1 1 unit 41E
65 30 54 ... 65 845 65 3RV2031-4JA10 1 1 unit 41E
73 37 62 ... 73 949 65 3RV2031-4KA10 1 1 unit 41E
802) 37 70 ... 80 1 040 65 3RV2031-4RA10 1 1 unit 41E
For special operating conditions down to -50 °C3)4)
25 11 18 ... 25 325 65 3RV2031-4DA10-0BA0 1 1 unit 41E
32 15 22 ... 32 416 65 3RV2031-4EA10-0BA0 1 1 unit 41E
65 30 54 ... 65 845 65 3RV2031-4JA10-0BA0 1 1 unit 41E
Size S2, with increased switching capacity
14 5.5 9.5 ... 14 208 100 3RV2032-4SA10 1 1 unit 41E
17 7.5 12 ... 17 260 100 3RV2032-4TA10 1 1 unit 41E
20 7.5 14 ... 20 260 100 3RV2032-4BA10 1 1 unit 41E
25 11 18 ... 25 325 100 3RV2032-4DA10 1 1 unit 41E
32 15 22 ... 32 416 100 3RV2032-4EA10 1 1 unit 41E
36 18.5 28 ... 36 520 100 3RV2032-4PA10 1 1 unit 41E
40 18.5 32 ... 40 585 100 3RV2032-4UA10 1 1 unit 41E
45 22 35 ... 45 650 100 3RV2032-4VA10 1 1 unit 41E
52 22 42 ... 52 741 100 3RV2032-4WA10 1 1 unit 41E
59 30 49 ... 59 845 100 3RV2032-4XA10 1 1 unit 41E
65 30 54 ... 65 845 100 3RV2032-4JA10 1 1 unit 41E
73 37 62 ... 73 949 100 3RV2032-4KA10 1 1 unit 41E
802) 37 70 ... 80 1 040 100 3RV2032-4RA10 1 1 unit 41E
1) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Auxiliary switches and other accessories can be ordered
starting and rated data of the motor to be protected must be considered separately (see page 7/48 onwards).
when selecting the units.
2)
Suitable for use with IE3 and IE4 motors up to a starting current of 720 A.
For higher starting currents we recommend using 3RV2 motor starter
protectors size S3.
3)
The 3RV2031-.....-0BA0 motor starter protectors have a mechanical
endurance of 250 operating cycles.
4) The motor starter protectors do not have UL/CSA approval and are not certified
either according to the European Explosion Protection Directive (ATEX) or
according to the International Explosion Protection Standard (IECEx).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/29
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For motor protection IE3 ready IE4 ready IE3/IE4 ready
AC-3e
CLASS 10, without auxiliary switches

3RV204.-4.A10

Rated Suitable for Setting range for Instantaneous Short-circuit Screw terminals PU PS* PG
current three-phase thermal overload electronic release breaking (UNIT,
motors1) release capacity at SET, M)
with P 400 V AC
In Icu Article No. Price
per PU
A kW A A kA
Size S3
40 18.5 28 ... 40 520 65 3RV2041-4FA10 1 1 unit 41E
50 22 36 ... 50 650 65 3RV2041-4HA10 1 1 unit 41E
63 30 45 ... 63 819 65 3RV2041-4JA10 1 1 unit 41E
75 37 57 ... 75 975 65 3RV2041-4KA10 1 1 unit 41E
84 45 65 ... 84 1 170 65 3RV2041-4RA10 1 1 unit 41E
7

93 45 75 ... 93 1 300 65 3RV2041-4YA10 1 1 unit 41E


1002) 45, 55 80 ... 100 1 300 65 3RV2041-4MA10 1 1 unit 41E
Size S3, with increased switching capacity
40 18.5 28 ... 40 520 100 3RV2042-4FA10 1 1 unit 41E
50 22 36 ... 50 650 100 3RV2042-4HA10 1 1 unit 41E
63 30 45 ... 63 819 100 3RV2042-4JA10 1 1 unit 41E
75 37 57 ... 75 975 100 3RV2042-4KA10 1 1 unit 41E
84 45 65 ... 84 1 170 100 3RV2042-4RA10 1 1 unit 41E
93 45 75 ... 93 1 300 100 3RV2042-4YA10 1 1 unit 41E
1002) 45, 55 80 ... 100 1 300 100 3RV2042-4MA10 1 1 unit 41E
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Auxiliary switches and other accessories can be ordered
starting and rated data of the motor to be protected must be considered separately (see page 7/48 onwards).
when selecting the units.
2)
Suitable for use with IE3 and IE4 motors up to a starting current of 780 A.
For higher starting currents we recommend using 3VA circuit breakers
(see Catalog LV 10).

* You can order this quantity or a multiple thereof.


7/30 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
AC-3e E3 ready IE4 ready IE3/IE4 ready For motor protection
CLASS 10, with transverse auxiliary switch (1 NO + 1 NC)
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41E

3RV2011-..A15 3RV2011-..A25, 3RV2.21-4.A15, 3RV2021-4.A25


3RV2011-1EA25-0BA0 3RV2021-4.A15-0BA0

Rated Suitable for Setting range for Instantaneous Short-circuit Screw terminals Spring-loaded
current three-phase thermal overload electronic breaking terminals
motors1) release release capacity at
with P 400 V AC
In Icu Article No. Price Article No. Price
per PU per PU
A kW A A kA
Size S00
0.16 0.04 0.11 ... 0.16 2.1 100 3RV2011-0AA15 3RV2011-0AA25
0.2 0.06 0.14 ... 0.2 2.6 100 3RV2011-0BA15 3RV2011-0BA25
0.25 0.06 0.18 ... 0.25 3.3 100 3RV2011-0CA15 3RV2011-0CA25
0.32 0.09 0.22 ... 0.32 4.2 100 3RV2011-0DA15 3RV2011-0DA25
0.4 0.09 0.28 ... 0.4 5.2 100 3RV2011-0EA15 3RV2011-0EA25

7
0.5 0.12 0.35 ... 0.5 6.5 100 3RV2011-0FA15 3RV2011-0FA25
0.63 0.18 0.45 ... 0.63 8.2 100 3RV2011-0GA15 3RV2011-0GA25
0.8 0.18 0.55 ... 0.8 10 100 3RV2011-0HA15 3RV2011-0HA25
1 0.25 0.7 ... 1 13 100 3RV2011-0JA15 3RV2011-0JA25
1.25 0.37 0.9 ... 1.25 16 100 3RV2011-0KA15 3RV2011-0KA25
1.6 0.55 1.1 ... 1.6 21 100 3RV2011-1AA15 3RV2011-1AA25
2 0.75 1.4 ... 2 26 100 3RV2011-1BA15 3RV2011-1BA25
2.5 0.75 1.8 ... 2.5 33 100 3RV2011-1CA15 3RV2011-1CA25
3.2 1.1 2.2 ... 3.2 42 100 3RV2011-1DA15 3RV2011-1DA25
4 1.5 2.8 ... 4 52 100 3RV2011-1EA15 3RV2011-1EA25
5 1.5 3.5 ... 5 65 100 3RV2011-1FA15 3RV2011-1FA25
6.3 2.2 4.5 ... 6.3 82 100 3RV2011-1GA15 3RV2011-1GA25
8 3 5.5 ... 8 104 100 3RV2011-1HA15 3RV2011-1HA25
10 4 7 ... 10 130 100 3RV2011-1JA15 3RV2011-1JA25
12.5 5.5 9 ... 12.5 163 100 3RV2011-1KA15 3RV2011-1KA25
16 7.5 10 ... 16 208 55 3RV2011-4AA15 3RV2011-4AA25
For special operating conditions down to -50 °C2)3)
2 0.06 1.4 ... 2 2.6 100 3RV2011-1BA15-0BA0 --
2.5 0.75 1.8 ... 2.5 33 100 3RV2011-1CA15-0BA0 --
4 1.5 2.8 ... 4 52 100 3RV2011-1EA15-0BA0 3RV2011-1EA25-0BA0
5 1.5 3.5 ... 5 65 100 3RV2011-1FA15-0BA0 --
6.3 2.2 4.5 ... 6.3 82 100 3RV2011-1GA15-0BA0 --
8 3 5.5 ... 8 104 100 3RV2011-1HA15-0BA0 --
12.5 5.5 9 ... 12.5 163 100 3RV2011-1KA15-0BA0 --
16 7.5 10 ... 16 208 55 3RV2011-4AA15-0BA0 --
Size S0
16 7.5 10 ... 16 208 55 3RV2021-4AA15 3RV2021-4AA25
20 7.5 13 ... 20 260 55 3RV2021-4BA15 3RV2021-4BA25
22 11 16 ... 22 286 55 3RV2021-4CA15 3RV2021-4CA25
25 11 18 ... 25 325 55 3RV2021-4DA15 3RV2021-4DA25
28 15 23 ... 28 364 55 3RV2021-4NA15 3RV2021-4NA25
324) 15 27 ... 32 400 55 3RV2021-4EA15 3RV2021-4EA25
365) 18.5 30 ... 36 432 20 3RV2021-4PA15 --
405) 18.5 34 ... 40 480 20 3RV2021-4FA15 --
For special operating conditions down to -50 °C2)3)
20 7.5 13 ... 20 260 55 3RV2021-4BA15-0BA0 --
324) 15 27 ... 32 400 55 3RV2021-4EA15-0BA0 --
1) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual 5) The devices must not be mounted side-by-side and they must not be
starting and rated data of the motor to be protected must be considered assembled with link modules with contactors. A lateral clearance of 9 mm
when selecting the units. is required. For use with IE3 and IE4 motors we recommend using 3RV2
2)
The 3RV20.1-.....-0BA0 motor starter protectors in sizes S00 and S0 have motor starter protectors size S2.
a mechanical endurance of 500 operating cycles. Auxiliary switches and other accessories can be ordered
3)
The motor starter protectors do not have UL/CSA approval and are not certified separately (see page 7/48 onwards).
either according to the European Explosion Protection Directive (ATEX) or
according to the International Explosion Protection Standard (IECEx).
4) Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using 3RV2 motor starter
protectors size S2.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/31
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For motor protection IE3 ready IE4 ready IE3/IE4 ready
AC-3e
CLASS 10, with transverse auxiliary switch (1 NO + 1 NC)

3RV2031-4..15, 3RV2032-4.A15 3RV2041-4.A15


3RV2031-4.A15-0BA0

Rated Suitable for Setting range for Instantaneous Short-circuit Screw terminals PU PS* PG
current three-phase thermal overload electronic release breaking (UNIT,
motors1) release capacity at SET, M)
with P 400 V AC
In Icu Article No. Price
per PU
A kW A A kA
Size S2
14 5.5 9.5 ... 14 208 65 3RV2031-4SA15 1 1 unit 41E
17 7.5 12 ... 17 260 65 3RV2031-4TA15 1 1 unit 41E
20 7.5 14 ... 20 260 65 3RV2031-4BA15 1 1 unit 41E
25 11 18 ... 25 325 65 3RV2031-4DA15 1 1 unit 41E
7

32 15 22 ... 32 416 65 3RV2031-4EA15 1 1 unit 41E


36 18.5 28 ... 36 520 65 3RV2031-4PA15 1 1 unit 41E
40 18.5 32 ... 40 585 65 3RV2031-4UA15 1 1 unit 41E
45 22 35 ... 45 650 65 3RV2031-4VA15 1 1 unit 41E
52 22 42 ... 52 741 65 3RV2031-4WA15 1 1 unit 41E
59 30 49 ... 59 845 65 3RV2031-4XA15 1 1 unit 41E
65 30 54 ... 65 845 65 3RV2031-4JA15 1 1 unit 41E
73 37 62 ... 73 949 65 3RV2031-4KA15 1 1 unit 41E
802) 37 70 ... 80 1 040 65 3RV2031-4RA15 1 1 unit 41E
For special operating conditions down to -50 °C3)4)
14 5.5 9.5 ... 14 208 65 3RV2031-4SA15-0BA0 1 1 unit 41E
20 7.5 14 ... 20 260 65 3RV2031-4BA15-0BA0 1 1 unit 41E
32 15 22 ... 32 416 65 3RV2031-4EA15-0BA0 1 1 unit 41E
45 22 35 ... 45 650 65 3RV2031-4VA15-0BA0 1 1 unit 41E
Size S2, with increased switching capacity
14 5.5 9.5 ... 14 208 10 3RV2032-4SA15 1 1 unit 41E
17 7.5 12 ... 17 260 100 3RV2032-4TA15 1 1 unit 41E
20 7.5 14 ... 20 260 100 3RV2032-4BA15 1 1 unit 41E
25 11 18 ... 25 325 100 3RV2032-4DA15 1 1 unit 41E
32 15 22 ... 32 416 100 3RV2032-4EA15 1 1 unit 41E
36 18.5 28 ... 36 520 100 3RV2032-4PA15 1 1 unit 41E
40 18.5 32 ... 40 585 100 3RV2032-4UA15 1 1 unit 41E
45 22 35 ... 45 650 100 3RV2032-4VA15 1 1 unit 41E
52 22 42 ... 52 741 100 3RV2032-4WA15 1 1 unit 41E
59 30 49 ... 59 845 100 3RV2032-4XA15 1 1 unit 41E
65 30 54 ... 65 845 100 3RV2032-4JA15 1 1 unit 41E
73 37 62 ... 73 949 100 3RV2032-4KA15 1 1 unit 41E
802) 37 70 ... 80 1 040 100 3RV2032-4RA15 1 1 unit 41E
Size S3
40 18.5 28 ... 40 520 65 3RV2041-4FA15 1 1 unit 41E
50 22 36 ... 50 650 65 3RV2041-4HA15 1 1 unit 41E
63 30 45 ... 63 819 65 3RV2041-4JA15 1 1 unit 41E
75 37 57 ... 75 975 65 3RV2041-4KA15 1 1 unit 41E
84 45 65 ... 84 1 170 65 3RV2041-4RA15 1 1 unit 41E
93 45 75 ... 93 1 300 65 3RV2041-4YA15 1 1 unit 41E
1005) 45, 55 80 ... 100 1 300 65 3RV2041-4MA15 1 1 unit 41E
1) 5)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Suitable for use with IE3 and IE4 motors up to a starting current of 780 A.
starting and rated data of the motor to be protected must be considered For higher starting currents we recommend using 3VA circuit breakers
when selecting the units. (see Catalog LV 10).
2)
Suitable for use with IE3 and IE4 motors up to a starting current of 720 A.
For higher starting currents we recommend using 3RV2 motor starter
Auxiliary switches and other accessories can be ordered
protectors size S3. separately (see page 7/48 onwards).
3) The 3RV2031-.....-0BA0 motor starter protectors have a mechanical
endurance of 250 operating cycles.
4)
The motor starter protectors do not have UL/CSA approval and are not certified
either according to the European Explosion Protection Directive (ATEX) or
according to the International Explosion Protection Standard (IECEx).

* You can order this quantity or a multiple thereof.


7/32 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
AC-3e E3 ready IE4 ready IE3/IE4 ready For motor protection
CLASS 20, without auxiliary switches

3RV2031-4.B10, 3RV2031-4.B10, 3RV2042-4.B10,


14 to 45 A; 52 to 65 A 40 to 100 A
3RV2031-4.B10-0BA0;
32 to 40 A

Rated Suitable for Setting range for Instantaneous Short-circuit Screw terminals PU PS* PG
current three-phase thermal overload electronic release breaking (UNIT,
motors1) release capacity at SET, M)
with P 400 V AC
In Icu Article No. Price
per PU
A kW A A kA
Size S2
14 5.5 9.5 ... 14 208 65 3RV2031-4SB10 1 1 unit 41E
17 7.5 12 ... 17 260 65 3RV2031-4TB10 1 1 unit 41E
20 7.5 14 ... 20 260 65 3RV2031-4BB10 1 1 unit 41E
25 11 18 ... 25 325 65 3RV2031-4DB10 1 1 unit 41E

7
32 15 22 ... 32 416 65 3RV2031-4EB10 1 1 unit 41E
36 18.5 28 ... 36 520 65 3RV2031-4PB10 1 1 unit 41E
40 18.5 32 ... 40 585 65 3RV2031-4UB10 1 1 unit 41E
45 22 35 ... 45 650 65 3RV2031-4VB10 1 1 unit 41E
52 22 42 ... 52 741 65 3RV2031-4WB10 1 1 unit 41E
59 30 49 ... 59 845 65 3RV2031-4XB10 1 1 unit 41E
65 30 54 ... 65 845 65 3RV2031-4JB10 1 1 unit 41E
For special operating conditions down to -50 °C2)3)
32 15 22 ... 32 416 65 3RV2031-4EB10-0BA0 1 1 unit 41E
36 18.5 28 ... 36 520 65 3RV2031-4PB10-0BA0 1 1 unit 41E
40 18.5 32 ... 40 585 65 3RV2031-4UB10-0BA0 1 1 unit 41E
Size S3, with increased switching capacity
40 18.5 28 ... 40 520 100 3RV2042-4FB10 1 1 unit 41E
50 22 36 ... 50 650 100 3RV2042-4HB10 1 1 unit 41E
63 30 45 ... 63 819 100 3RV2042-4JB10 1 1 unit 41E
75 37 57 ... 75 975 100 3RV2042-4KB10 1 1 unit 41E
84 45 65 ... 84 1 170 100 3RV2042-4RB10 1 1 unit 41E
93 45 75 ... 93 1 300 100 3RV2042-4YB10 1 1 unit 41E
1004) 45, 55 80 ... 100 1 300 100 3RV2042-4MB10 1 1 unit 41E
1) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Auxiliary switches and other accessories can be ordered
starting and rated data of the motor to be protected must be considered separately (see page 7/48 onwards).
when selecting the units.
2)
The 3RV2031-.....-0BA0 motor starter protectors have a mechanical
endurance of 250 operating cycles.
3)
The motor starter protectors do not have UL/CSA approval and are not certified
either according to the European Explosion Protection Directive (ATEX) or
according to the International Explosion Protection Standard (IECEx).
4) Suitable for use with IE3 and IE4 motors up to a starting current of 780 A.
For higher starting currents we recommend using 3VA circuit breakers
(see Catalog LV 10).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/33
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For motor protection IE3 ready IE4 ready IE3/IE4 ready
AC-3e
CLASS 20, with transverse auxiliary switch (1 NO + 1 NC)

3RV2031-4.B15, 3RV2031-4.B15,
14 to 45 A 52 to 65 A

Rated Suitable for Setting range for Instantaneous Short-circuit Screw terminals PU PS* PG
current three-phase thermal overload electronic release breaking capacity (UNIT,
motors1) release at 400 V AC SET, M)
with P
In Icu Article No. Price
per PU
A kW A A kA
Size S2
14 5.5 9.5 ... 14 208 65 3RV2031-4SB15 1 1 unit 41E
17 7.5 12 ... 17 260 65 3RV2031-4TB15 1 1 unit 41E
20 7.5 14 ... 20 260 65 3RV2031-4BB15 1 1 unit 41E
25 11 18 ... 25 325 65 3RV2031-4DB15 1 1 unit 41E
32 15 22 ... 32 416 65 3RV2031-4EB15 1 1 unit 41E
36 18.5 28 ... 36 520 65 3RV2031-4PB15 1 1 unit 41E
7

40 18.5 32 ... 40 585 65 3RV2031-4UB15 1 1 unit 41E


45 22 35 ... 45 650 65 3RV2031-4VB15 1 1 unit 41E
52 22 42 ... 52 741 65 3RV2031-4WB15 1 1 unit 41E
59 30 49 ... 59 845 65 3RV2031-4XB15 1 1 unit 41E
65 30 54 ... 65 845 65 3RV2031-4JB15 1 1 unit 41E
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Auxiliary switches and other accessories can be ordered
starting and rated data of the motor to be protected must be considered separately (see page 7/48 onwards).
when selecting the units.

* You can order this quantity or a multiple thereof.


7/34 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
AC-3e E3 ready IE4 ready IE3/IE4 ready For motor protection with overload relay function

■ Selection and ordering data


CLASS 10, with overload relay function (automatic RESET), without auxiliary switches

3RV2111-..A10 3RV2121-4.A10

Rated Suitable for Setting range for Instantaneous Short-circuit Screw terminals PU PS* PG
current three-phase thermal overload electronic release breaking capacity (UNIT,
motors1) release at 400 V AC SET, M)
with P
In Icu Article No. Price
per PU
A kW A A kA
Size S002)
0.16 0.04 0.11 ... 0.16 2.1 100 3RV2111-0AA10 1 1 unit 41E
0.2 0.06 0.14 ... 0.2 2.6 100 3RV2111-0BA10 1 1 unit 41E
0.25 0.06 0.18 ... 0.25 3.3 100 3RV2111-0CA10 1 1 unit 41E
0.32 0.09 0.22 ... 0.32 4.2 100 3RV2111-0DA10 1 1 unit 41E
0.4 0.09 0.28 ... 0.4 5.2 100 3RV2111-0EA10 1 1 unit 41E
0.5 0.12 0.35 ... 0.5 6.5 100 3RV2111-0FA10 1 1 unit 41E
0.63 0.18 0.45 ... 0.63 8.2 100 3RV2111-0GA10 1 1 unit 41E
0.8 0.18 0.55 ... 0.8 10 100 3RV2111-0HA10 1 1 unit 41E

7
1 0.25 0.7 ... 1 13 100 3RV2111-0JA10 1 1 unit 41E
1.25 0.37 0.9 ... 1.25 16 100 3RV2111-0KA10 1 1 unit 41E
1.6 0.55 1.1 ... 1.6 21 100 3RV2111-1AA10 1 1 unit 41E
2 0.75 1.4 ... 2 26 100 3RV2111-1BA10 1 1 unit 41E
2.5 0.75 1.8 ... 2.5 33 100 3RV2111-1CA10 1 1 unit 41E
3.2 1.1 2.2 ... 3.2 42 100 3RV2111-1DA10 1 1 unit 41E
4 1.5 2.8 ... 4 52 100 3RV2111-1EA10 1 1 unit 41E
5 1.5 3.5 ... 5 65 100 3RV2111-1FA10 1 1 unit 41E
6.3 2.2 4.5 ... 6.3 82 100 3RV2111-1GA10 1 1 unit 41E
8 3 5.5 ... 8 104 100 3RV2111-1HA10 1 1 unit 41E
10 4 7 ... 10 130 100 3RV2111-1JA10 1 1 unit 41E
12.5 5.5 9 ... 12.5 163 100 3RV2111-1KA10 1 1 unit 41E
16 7.5 10 ... 16 208 55 3RV2111-4AA10 1 1 unit 41E
Size S02)
16 7.5 10 ... 16 208 55 3RV2121-4AA10 1 1 unit 41E
20 7.5 13 ... 20 260 55 3RV2121-4BA10 1 1 unit 41E
22 11 16 ... 22 286 55 3RV2121-4CA10 1 1 unit 41E
25 11 18 ... 25 325 55 3RV2121-4DA10 1 1 unit 41E
28 15 23 ... 28 364 55 3RV2121-4NA10 1 1 unit 41E
323) 15 27 ... 32 400 55 3RV2121-4EA10 1 1 unit 41E
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Auxiliary switches and other accessories can be ordered
starting and rated data of the motor to be protected must be considered separately (see page 7/48 onwards).
when selecting the units.
2) Accessories for mounting on the right and 3RV1915 3-phase busbars
cannot be used.
3)
Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using 3RV2 motor starter
protectors size S2.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/35
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For motor protection with overload relay function IE3 ready IE4 ready IE3/IE4 ready
AC-3e
CLASS 10, with overload relay function (Automatic RESET), without auxiliary switches

3RV2131-4.A10 3RV2142-4.A10

Rated Suitable for Setting range for Instantaneous Short-circuit Screw terminals PU PS* PG
current three-phase thermal overload electronic release breaking capacity (UNIT,
motors1) release at 400 V AC SET, M)
with P
In Icu Article No. Price
per PU
A kW A A kA
Size S22)
14 5.5 9.5 ... 14 208 65 3RV2131-4SA10 1 1 unit 41E
17 7.5 12 ... 17 260 65 3RV2131-4TA10 1 1 unit 41E
20 7.5 14 ... 20 260 65 3RV2131-4BA10 1 1 unit 41E
25 11 18 ... 25 325 65 3RV2131-4DA10 1 1 unit 41E
32 15 22 ... 32 416 65 3RV2131-4EA10 1 1 unit 41E
7

36 18.5 28 ... 36 520 65 3RV2131-4PA10 1 1 unit 41E


40 18.5 32 ... 40 585 65 3RV2131-4UA10 1 1 unit 41E
45 22 35 ... 45 650 65 3RV2131-4VA10 1 1 unit 41E
52 32 42 ... 52 741 65 3RV2131-4WA10 1 1 unit 41E
59 30 49 ... 59 845 65 3RV2131-4XA10 1 1 unit 41E
65 30 54 ... 65 845 65 3RV2131-4JA10 1 1 unit 41E
73 37 62 ... 73 949 65 3RV2131-4KA10 1 1 unit 41E
803) 37 70 ... 80 1 040 65 3RV2131-4RA10 1 1 unit 41E
Size S3, with increased switching capacity2)
40 18.5 28 ... 40 520 100 3RV2142-4FA10 1 1 unit 41E
50 22 36 ... 50 650 100 3RV2142-4HA10 1 1 unit 41E
63 30 45 ... 63 819 100 3RV2142-4JA10 1 1 unit 41E
75 37 57 ... 75 975 100 3RV2142-4KA10 1 1 unit 41E
84 45 65 ... 84 1 170 100 3RV2142-4RA10 1 1 unit 41E
93 45 75 ... 93 1 300 100 3RV2142-4YA10 1 1 unit 41E
1004) 45, 55 80 ... 100 1 300 100 3RV2142-4MA10 1 1 unit 41E
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Auxiliary switches and other accessories can be ordered
starting and rated data of the motor to be protected must be considered separately (see page 7/48 onwards).
when selecting the units.
2)
Accessories for mounting on the right cannot be used.
3) Suitable for use with IE3 and IE4 motors up to a starting current of 720 A.
For higher starting currents we recommend using 3RV2 motor starter
protectors size S3.
4)
Suitable for use with IE3 and IE4 motors up to a starting current of 780 A.
For higher starting currents we recommend using 3VA circuit breakers
(see Catalog LV 10).

* You can order this quantity or a multiple thereof.


7/36 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
AC-3e E3 ready IE4 ready IE3/IE4 ready For starter combinations

■ Selection and ordering data


Without auxiliary switches
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41E

3RV2311-..C10 3RV2311-..C20,
3RV2311-4AC20-0BA0

Rated Suitable for Thermal overload Instantaneous Short-circuit Screw terminals Spring-loaded
current three-phase release2) electronic breaking terminals
motors1) release capacity at
with P 400 V AC
In Icu Article No. Price Article No. Price
per PU per PU
A kW A A kA
Size S00
0.16 0.04 Without 2.1 100 3RV2311-0AC10 3RV2311-0AC20
0.2 0.06 Without 2.6 100 3RV2311-0BC10 3RV2311-0BC20

7
0.25 0.06 Without 3.3 100 3RV2311-0CC10 3RV2311-0CC20
0.32 0.09 Without 4.2 100 3RV2311-0DC10 3RV2311-0DC20
0.4 0.09 Without 5.2 100 3RV2311-0EC10 3RV2311-0EC20
0.5 0.12 Without 6.5 100 3RV2311-0FC10 3RV2311-0FC20
0.63 0.18 Without 8.2 100 3RV2311-0GC10 3RV2311-0GC20
0.8 0.18 Without 10 100 3RV2311-0HC10 3RV2311-0HC20
1 0.25 Without 13 100 3RV2311-0JC10 3RV2311-0JC20
1.25 0.37 Without 16 100 3RV2311-0KC10 3RV2311-0KC20
1.6 0.55 Without 21 100 3RV2311-1AC10 3RV2311-1AC20
2 0.75 Without 26 100 3RV2311-1BC10 3RV2311-1BC20
2.5 0.75 Without 33 100 3RV2311-1CC10 3RV2311-1CC20
3.2 1.1 Without 42 100 3RV2311-1DC10 3RV2311-1DC20
4 1.5 Without 52 100 3RV2311-1EC10 3RV2311-1EC20
5 1.5 Without 65 100 3RV2311-1FC10 3RV2311-1FC20
6.3 2.2 Without 82 100 3RV2311-1GC10 3RV2311-1GC20
8 3 Without 104 100 3RV2311-1HC10 3RV2311-1HC20
10 4 Without 130 100 3RV2311-1JC10 3RV2311-1JC20
12.5 5.5 Without 163 100 3RV2311-1KC10 3RV2311-1KC20
16 7.5 Without 208 55 3RV2311-4AC10 3RV2311-4AC20
For special operating conditions down to -50 °C3)4)
16 7.5 Without 208 55 -- 3RV2311-4AC20-0BA0
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Auxiliary switches and other accessories can be ordered
starting and rated data of the motor to be protected must be considered separately (see page 7/48 onwards).
when selecting the units.
2)
For overload protection of the motors, appropriate overload relays must
be used.
3) The 3RV2311-.....-0BA0 motor starter protectors have a mechanical
endurance of 500 operating cycles.
4)
The motor starter protectors do not have UL/CSA approval and are not certified
either according to the European Explosion Protection Directive (ATEX) or
according to the International Explosion Protection Standard (IECEx).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/37
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For starter combinations IE3 ready IE4 ready IE3/IE4 ready
AC-3e
Without auxiliary switches
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41E

3RV2321-..C10 3RV2321-..C20,
3RV2321-4AC20-0BA0

Rated Suitable for Thermal overload Instantaneous Short-circuit Screw terminals Spring-loaded
current three-phase release2) electronic breaking terminals
motors1) release capacity at
with P 400 V AC
In Icu Article No. Price Article No. Price
per PU per PU
A kW A A kA
Size S0
1.6 0.55 Without 21 100 3RV2321-1AC10 3RV2321-1AC20
2 0.75 Without 26 100 3RV2321-1BC10 3RV2321-1BC20
2.5 0.75 Without 33 100 3RV2321-1CC10 3RV2321-1CC20
3.2 1.1 Without 42 100 3RV2321-1DC10 3RV2321-1DC20
4 1.5 Without 52 100 3RV2321-1EC10 3RV2321-1EC20
7

5 1.5 Without 65 100 3RV2321-1FC10 3RV2321-1FC20


6.3 2.2 Without 82 100 3RV2321-1GC10 3RV2321-1GC20
8 3 Without 104 100 3RV2321-1HC10 3RV2321-1HC20
10 4 Without 130 100 3RV2321-1JC10 3RV2321-1JC20
12.5 5.5 Without 163 100 3RV2321-1KC10 3RV2321-1KC20
16 7.5 Without 208 55 3RV2321-4AC10 3RV2321-4AC20
20 7.5 Without 260 55 3RV2321-4BC10 3RV2321-4BC20
22 11 Without 286 55 3RV2321-4CC10 3RV2321-4CC20
25 11 Without 325 55 3RV2321-4DC10 3RV2321-4DC20
28 15 Without 364 55 3RV2321-4NC10 3RV2321-4NC20
323) 15 Without 400 55 3RV2321-4EC10 3RV2321-4EC20

364) 18.5 Without 432 20 3RV2321-4PC10 --


404) 18.5 Without 480 20 3RV2321-4FC10 --
For special operating conditions down to -50 °C5)6)
16 7.5 Without 208 55 -- 3RV2321-4AC20-0BA0
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Auxiliary switches and other accessories can be ordered
starting and rated data of the motor to be protected must be considered separately (see page 7/48 onwards).
when selecting the units.
2) For overload protection of the motors, appropriate overload relays must
be used.
3)
Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using 3RV2 motor starter
protectors size S2.
4) The devices must not be mounted side-by-side and they must not be
assembled with link modules with contactors. A lateral clearance of 9 mm
is required. For use with IE3 and IE4 motors we recommend using 3RV2
motor starter protectors size S2.
5)
The 3RV2321-.....-0BA0 motor starter protectors have a mechanical
endurance of 500 operating cycles.
6)
The motor starter protectors do not have UL/CSA approval and are not certified
either according to the European Explosion Protection Directive (ATEX) or
according to the International Explosion Protection Standard (IECEx).

* You can order this quantity or a multiple thereof.


7/38 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
AC-3e E3 ready IE4 ready IE3/IE4 ready For starter combinations
Without auxiliary switches

3RV2331-4.C10, 3RV2331-4.C10, 3RV2332-4.C10, 3RV2332-4.C10, 3RV234.-4.C10,


14 to 45 A 52 to 80 A 14 to 45 A 52 to 80 A 40 to 100 A

Rated Suitable for three- Thermal overload Instantaneous Short-circuit Screw terminals PU PS* PG
current phase motors1) release2) electronic release breaking capacity (UNIT,
with P at 400 V AC SET, M)
In Icu Article No. Price
per PU
A kW A A kA
Size S2
14 5.5 Without 208 65 3RV2331-4SC10 1 1 unit 41E
17 7.5 Without 260 65 3RV2331-4TC10 1 1 unit 41E
20 7.5 Without 260 65 3RV2331-4BC10 1 1 unit 41E
25 11 Without 325 65 3RV2331-4DC10 1 1 unit 41E

7
32 15 Without 416 65 3RV2331-4EC10 1 1 unit 41E
36 18.5 Without 520 65 3RV2331-4PC10 1 1 unit 41E
40 18.5 Without 585 65 3RV2331-4UC10 1 1 unit 41E
45 22 Without 650 65 3RV2331-4VC10 1 1 unit 41E
52 22 Without 741 65 3RV2331-4WC10 1 1 unit 41E
59 30 Without 845 65 3RV2331-4XC10 1 1 unit 41E
65 30 Without 845 65 3RV2331-4JC10 1 1 unit 41E
73 37 Without 949 65 3RV2331-4KC10 1 1 unit 41E
803) 37 Without 1040 65 3RV2331-4RC10 1 1 unit 41E
Size S2, with increased switching capacity
14 5.5 Without 208 100 3RV2332-4SC10 1 1 unit 41E
17 7.5 Without 260 100 3RV2332-4TC10 1 1 unit 41E
20 7.5 Without 260 100 3RV2332-4BC10 1 1 unit 41E
25 11 Without 325 100 3RV2332-4DC10 1 1 unit 41E
32 15 Without 416 100 3RV2332-4EC10 1 1 unit 41E
36 18.5 Without 520 100 3RV2332-4PC10 1 1 unit 41E
40 18.5 Without 585 100 3RV2332-4UC10 1 1 unit 41E
45 22 Without 650 100 3RV2332-4VC10 1 1 unit 41E
52 22 Without 741 100 3RV2332-4WC10 1 1 unit 41E
59 30 Without 845 100 3RV2332-4XC10 1 1 unit 41E
65 30 Without 845 100 3RV2332-4JC10 1 1 unit 41E
73 37 Without 949 100 3RV2332-4KC10 1 1 unit 41E
803) 37 Without 1 040 100 3RV2332-4RC10 1 1 unit 41E
Size S3
40 18.5 Without 520 65 3RV2341-4FC10 1 1 unit 41E
50 22 Without 650 65 3RV2341-4HC10 1 1 unit 41E
63 30 Without 819 65 3RV2341-4JC10 1 1 unit 41E
75 37 Without 975 65 3RV2341-4KC10 1 1 unit 41E
84 45 Without 1 170 65 3RV2341-4RC10 1 1 unit 41E
93 45 Without 1 300 65 3RV2341-4YC10 1 1 unit 41E
1004) 45, 55 Without 1 300 65 3RV2341-4MC10 1 1 unit 41E
Size S3, with increased switching capacity
40 18.5 Without 520 100 3RV2342-4FC10 1 1 unit 41E
50 22 Without 650 100 3RV2342-4HC10 1 1 unit 41E
63 30 Without 819 100 3RV2342-4JC10 1 1 unit 41E
75 37 Without 975 100 3RV2342-4KC10 1 1 unit 41E
84 45 Without 1 170 100 3RV2342-4RC10 1 1 unit 41E
93 45 Without 1 300 100 3RV2342-4YC10 1 1 unit 41E
1004) 45, 55 Without 1 300 100 3RV2342-4MC10 1 1 unit 41E
1) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual 4) Suitable for use with IE3 and IE4 motors up to a starting current of 780 A.
starting and rated data of the motor to be protected must be considered For higher starting currents we recommend using 3VA circuit breakers
when selecting the units. (see Catalog LV 10).
2)
For overload protection of the motors, appropriate overload relays must
be used.
Auxiliary switches and other accessories can be ordered
3)
Suitable for use with IE3 and IE4 motors up to a starting current of 720 A.
separately (see page 7/48 onwards).
For higher starting currents we recommend using 3RV2 motor starter
protectors size S3.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/39
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For transformer protection

■ Selection and ordering data


CLASS 10, without auxiliary switches
Motor starter protectors for the protection of transformers with high inrush current
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41E

3RV2411-..A10, 3RV2411-..A20
3RV2411-..A10-0BA0

Rated Setting range for Instantaneous Short-circuit Screw terminals Spring-loaded


current thermal overload electronic breaking capacity terminals
release release at 400 V AC
In Icu Article No. Price Article No. Price
per PU per PU
A A A kA
Size S00
0.16 0.11 ... 0.16 3.3 100 3RV2411-0AA10 3RV2411-0AA20
0.2 0.14 ... 0.2 4.2 100 3RV2411-0BA10 3RV2411-0BA20
7

0.25 0.18 ... 0.25 5.2 100 3RV2411-0CA10 3RV2411-0CA20


0.32 0.22 ... 0.32 6.5 100 3RV2411-0DA10 3RV2411-0DA20
0.4 0.28 ... 0.4 8.2 100 3RV2411-0EA10 3RV2411-0EA20
0.5 0.35 ... 0.5 10 100 3RV2411-0FA10 3RV2411-0FA20
0.63 0.45 ... 0.63 13 100 3RV2411-0GA10 3RV2411-0GA20
0.8 0.55 ... 0.8 16 100 3RV2411-0HA10 3RV2411-0HA20
1 0.7 ... 1 21 100 3RV2411-0JA10 3RV2411-0JA20
1.25 0.9 ... 1.25 26 100 3RV2411-0KA10 3RV2411-0KA20
1.6 1.1 ... 1.6 33 100 3RV2411-1AA10 3RV2411-1AA20
2 1.4 ... 2 42 100 3RV2411-1BA10 3RV2411-1BA20
2.5 1.8 ... 2.5 52 100 3RV2411-1CA10 3RV2411-1CA20
3.2 2.2 ... 3.2 65 100 3RV2411-1DA10 3RV2411-1DA20
4 2.8 ... 4 82 100 3RV2411-1EA10 3RV2411-1EA20
5 3.5 ... 5 104 100 3RV2411-1FA10 3RV2411-1FA20
6.3 4.5 ... 6.3 130 100 3RV2411-1GA10 3RV2411-1GA20
8 5.5 ... 8 163 100 3RV2411-1HA10 3RV2411-1HA20
10 7 ... 10 208 100 3RV2411-1JA10 3RV2411-1JA20
12.5 9 ... 12.5 260 100 3RV2411-1KA10 3RV2411-1KA20
16 10 ... 16 286 55 3RV2411-4AA10 3RV2411-4AA20
Without phase asymmetry/failure detection for 1-, 2- and
3-phase loads1)
0.4 0.28 ... 0.4 8.2 100 -- 3RV2411-0EA20-0DA0
1.6 1.1 ... 1.6 33 100 -- 3RV2411-1AA20-0DA0
2 1.4 ... 2 42 100 -- 3RV2411-1BA20-0DA0
2.5 1.8 ... 2.5 52 100 -- 3RV2411-1CA20-0DA0
3.2 2.2 ... 3.2 65 100 -- 3RV2411-1DA20-0DA0
4 2.8 ... 4 82 100 -- 3RV2411-1EA20-0DA0
5 3.5 ... 5 104 100 -- 3RV2411-1FA20-0DA0
6.3 4.5 ... 6.3 130 100 -- 3RV2411-1GA20-0DA0
8 5.5 ... 8 163 100 -- 3RV2411-1HA20-0DA0
10 7 ... 10 208 100 -- 3RV2411-1JA20-0DA0
For special operating conditions down to -50 °C2)3)
2.5 1.8 ... 2.5 52 100 3RV2411-1CA10-0BA0 --
6.3 4.5 ... 6.3 130 100 3RV2411-1GA10-0BA0 --
8 5.5 ... 8 163 100 3RV2411-1HA10-0BA0 --
10 7 ... 10 208 100 3RV2411-1JA10-0BA0 --
16 10 ... 16 286 55 3RV2411-4AA10-0BA0 --
1)
The motor starter protectors do not have UL/CSA approval and are not certified Auxiliary switches and other accessories can be ordered
either according to the European Explosion Protection Directive (ATEX) or separately (see page 7/48 onwards).
according to the International Explosion Protection Standard (IECEx).
2)
The motor starter protectors have IEC approval, but not UL/CSA approval.
3) The 3RV2411-.....-0BA0 motor starter protectors have a mechanical
endurance of 500 operating cycles.

* You can order this quantity or a multiple thereof.


7/40 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For transformer protection
CLASS 10, without auxiliary switches
Motor starter protectors for the protection of transformers with high inrush current
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41E

3RV2421-..A10, 3RV2421-4.A20;
3RV2421-4BA10-0BA0, 3RV2421-4.A20-0DA0,
32 A 16 and 20 A

Rated Setting range for Instantaneous Short-circuit Screw terminals Spring-loaded


current thermal overload electronic breaking capacity terminals
release release at 400 V AC
In Icu Article No. Price Article No. Price
per PU per PU
A A A kA
Size S0
0.16 0.11 ... 0.16 3.3 100 3RV2421-0AA10 --
0.2 0.14 ... 0.2 4.2 100 3RV2421-0BA10 --
0.25 0.18 ... 0.25 5.2 100 3RV2421-0CA10 --

7
0.32 0.22 ... 0.32 6.5 100 3RV2421-0DA10 --
0.4 0.28 ... 0.4 8.2 100 3RV2421-0EA10 --
0.5 0.35 ... 0.5 10 100 3RV2421-0FA10 --
0.63 0.45 ... 0.63 13 100 3RV2421-0GA10 --
0.8 0.55 ... 0.8 16 100 3RV2421-0HA10 --
1 0.7 ... 1 21 100 3RV2421-0JA10 --
1.25 0.9 ... 1.25 26 100 3RV2421-0KA10 --
1.6 1.1 ... 1.6 33 100 3RV2421-1AA10 --
2 1.4 ... 2 42 100 3RV2421-1BA10 --
2.5 1.8 ... 2.5 52 100 3RV2421-1CA10 --
3.2 2.2 ... 3.2 65 100 3RV2421-1DA10 --
4 2.8 ... 4 82 100 3RV2421-1EA10 --
5 3.5 ... 5 104 100 3RV2421-1FA10 --
6.3 4.5 ... 6.3 130 100 3RV2421-1GA10 --
8 5.5 ... 8 163 100 3RV2421-1HA10 --
10 7 ... 10 208 100 3RV2421-1JA10 --
12.5 9 ... 12.5 260 100 3RV2421-1KA10 --
16 10 ... 16 286 55 3RV2421-4AA10 3RV2421-4AA20
20 13 ... 20 325 55 3RV2421-4BA10 3RV2421-4BA20
22 16 ... 22 364 55 3RV2421-4CA10 3RV2421-4CA20
25 18 ... 25 400 55 3RV2421-4DA10 3RV2421-4DA20
Without phase asymmetry/failure detection for 1-, 2- and
3-phase loads1)
16 10 ... 16 286 55 -- 3RV2421-4AA20-0DA0
20 13 ... 20 325 55 -- 3RV2421-4BA20-0DA0
For special operating conditions down to -50 °C2)3)
20 13 ... 20 325 55 3RV2421-4BA10-0BA0 --
1) The motor starter protectors do not have UL/CSA approval and are not certified Auxiliary switches and other accessories can be ordered
either according to the European Explosion Protection Directive (ATEX) or separately (see page 7/48 onwards).
according to the International Explosion Protection Standard (IECEx).
2)
The motor starter protectors have IEC approval, but not UL/CSA approval.
3)
The 3RV2431-.....-0BA0 motor starter protectors have a mechanical
endurance of 250 operating cycles.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/41
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For transformer protection
CLASS 10, without auxiliary switches
Motor starter protectors for the protection of transformers with high inrush current
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41E

3RV2431-4.A10, 3RV2431-4.A10,
14 to 40 A; 45 to 65 A
3RV2431-4EA10-0BA0,
32 A

Rated Setting range for Instantaneous Short-circuit Screw terminals Spring-loaded


current thermal overload electronic breaking capacity terminals
release release at 400 V AC
In Icu Article No. Price Article No. Price
per PU per PU
A A A kA
7

Size S2
14 9.5 ... 14 328 65 3RV2431-4SA10 --
17 12 ... 17 410 65 3RV2431-4TA10 --
20 14 ... 20 410 65 3RV2431-4BA10 --
25 18 ... 25 512 65 3RV2431-4DA10 --
32 22 ... 32 656 65 3RV2431-4EA10 --
36 28 ... 36 820 65 3RV2431-4PA10 --
40 32 ... 40 820 65 3RV2431-4UA10 --
45 35 ... 45 922 65 3RV2431-4VA10 --
52 42 ... 52 1 025 65 3RV2431-4WA10 --
59 49 ... 59 1 040 65 3RV2431-4XA10 --
65 54 ... 65 1 040 65 3RV2431-4JA10 --
For special operating conditions down to -50 °C1)2)
32 22 ... 32 656 65 3RV2431-4EA10-0BA0 --
1) The motor starter protectors do not have UL/CSA approval and are not certified
either according to the European Explosion Protection Directive (ATEX) or
according to the International Explosion Protection Standard (IECEx).
2)
The 3RV2431-.....-0BA0 motor starter protectors have a mechanical
endurance of 250 operating cycles.
Auxiliary switches and other accessories can be ordered
separately (see page 7/48 onwards).

* You can order this quantity or a multiple thereof.


7/42 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For transformer protection
CLASS 10, with transverse auxiliary switch (1 NO + 1 NC)
Motor starter protectors for the protection of transformers with high inrush current

3RV2411-..A15 3RV2421-4.A15

Rated Setting range for Instantaneous Short-circuit Screw terminals PU PS* PG


current thermal overload electronic release breaking capacity (UNIT,
release at 400 V AC SET, M)
In Icu Article No. Price
per PU
A A A kA
Size S00
0.16 0.11 ... 0.16 3.3 100 3RV2411-0AA15 1 1 unit 41E
0.2 0.14 ... 0.2 4.2 100 3RV2411-0BA15 1 1 unit 41E
0.25 0.18 ... 0.25 5.2 100 3RV2411-0CA15 1 1 unit 41E
0.32 0.22 ... 0.32 6.5 100 3RV2411-0DA15 1 1 unit 41E
0.4 0.28 ... 0.4 8.2 100 3RV2411-0EA15 1 1 unit 41E
0.5 0.35 ... 0.5 10 100 3RV2411-0FA15 1 1 unit 41E
0.63 0.45 ... 0.63 13 100 3RV2411-0GA15 1 1 unit 41E
0.8 0.55 ... 0.8 16 100 3RV2411-0HA15 1 1 unit 41E
1 0.7 ... 1 21 100 3RV2411-0JA15 1 1 unit 41E

7
1.25 0.9 ... 1.25 26 100 3RV2411-0KA15 1 1 unit 41E
1.6 1.1 ... 1.6 33 100 3RV2411-1AA15 1 1 unit 41E
2 1.4 ... 2 42 100 3RV2411-1BA15 1 1 unit 41E
2.5 1.8 ... 2.5 52 100 3RV2411-1CA15 1 1 unit 41E
3.2 2.2 ... 3.2 65 100 3RV2411-1DA15 1 1 unit 41E
4 2.8 ... 4 82 100 3RV2411-1EA15 1 1 unit 41E
5 3.5 ... 5 104 100 3RV2411-1FA15 1 1 unit 41E
6.3 4.5 ... 6.3 130 100 3RV2411-1GA15 1 1 unit 41E
8 5.5 ... 8 163 100 3RV2411-1HA15 1 1 unit 41E
10 7 ... 10 208 100 3RV2411-1JA15 1 1 unit 41E
12.5 9 ... 12.5 260 100 3RV2411-1KA15 1 1 unit 41E
16 10 ... 16 286 55 3RV2411-4AA15 1 1 unit 41E
Size S0
16 10 ... 16 286 55 3RV2421-4AA15 1 1 unit 41E
20 13 ... 20 325 55 3RV2421-4BA15 1 1 unit 41E
22 16 ... 22 364 55 3RV2421-4CA15 1 1 unit 41E
25 18 ... 25 400 55 3RV2421-4DA15 1 1 unit 41E

Auxiliary switches and other accessories can be ordered


separately (see page 7/48 onwards).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/43
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For system protection

■ Selection and ordering data


CLASS 10, without auxiliary switches PU (UNIT, SET, M) = 1
PS* = 1 unit
The motor starter protectors are suitable for 1-, 2- and 3-phase PG = 41E
loads and do not feature phase asymmetry and phase failure
detection. They do not have UL/CSA approval and are not
certified either according to the European Explosion Protection
Directive (ATEX) or according to the International Explosion
Protection Standard (IECEx).

3RV2021-..A10-0DA0 3RV2021-1EA20-0DA0 3RV2041-4.A10-0DA0

Rated Suitable for Setting range Instanta- Short-circuit Screw terminals Spring-loaded
current three-phase for thermal neous breaking capacity terminals
motors1) overload electronic at 400 V AC
with } release release
7

In Icu Article No. Price Article No. Price


per PU per PU
A kW A A kA
Size S0
4 1.5 2.8 ... 4 52 100 3RV2021-1EA10-0DA0 3RV2021-1EA20-0DA0
6.3 2.2 4.5 ... 6.3 82 100 3RV2021-1GA10-0DA0 --
8 3 5.5 ... 8 104 100 3RV2021-1HA10-0DA0 --
10 4 7 ... 10 130 100 3RV2021-1JA10-0DA0 --
12.5 5.5 9 ... 12.5 163 100 3RV2021-1KA10-0DA0 --
16 7.5 10 ... 16 208 55 3RV2021-4AA10-0DA0 --
20 7.5 13 ... 20 260 55 3RV2021-4BA10-0DA0 --
25 11 18 ... 25 325 55 3RV2021-4DA10-0DA0 --
32 15 27 ... 32 400 55 3RV2021-4EA10-0DA0 --
Size S3
40 18.5 28 ... 40 520 65 3RV2041-4FA10-0DA0 --
50 22 36 ... 50 650 65 3RV2041-4HA10-0DA0 --
63 30 45 ... 63 819 65 3RV2041-4JA10-0DA0 --
84 45 65 ... 84 1 170 65 3RV2041-4RA10-0DA0 --
100 45, 55 80 ... 100 1 300 65 3RV2041-4MA10-0DA0 --
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Auxiliary switches and other accessories can be ordered
starting and rated data of the motor to be protected must be considered separately (see page 7/48 onwards).
when selecting the units.

* You can order this quantity or a multiple thereof.


7/44 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For system protection according to UL 489/CSA C22.2 No. 5

■ Selection and ordering data


Without auxiliary switches
Circuit breakers for system protection and non-motor loads according to UL/CSA

3RV2711-..D10 3RV2721-4.D10 3RV2742-5.D10

Rated current1) Thermal Instantaneous Short-circuit breaking Screw terminals PU PS* PG


overload release electronic capacity at (UNIT,
(non-adjustable) release 480 Y/277 V AC2) 480 V AC SET, M)
In1) Ibc Article No. Price
per PU
A A A kA kA
Size S00
0.16 0.16 2.1 65 -- 3RV2711-0AD10 1 1 unit 41E
0.2 0.2 2.6 65 -- 3RV2711-0BD10 1 1 unit 41E
0.25 0.25 3.3 65 -- 3RV2711-0CD10 1 1 unit 41E
0.32 0.32 4.2 65 -- 3RV2711-0DD10 1 1 unit 41E

7
0.4 0.4 5.2 65 -- 3RV2711-0ED10 1 1 unit 41E
0.5 0.5 6.5 65 -- 3RV2711-0FD10 1 1 unit 41E
0.63 0.63 8.2 65 -- 3RV2711-0GD10 1 1 unit 41E
0.8 0.8 10 65 -- 3RV2711-0HD10 1 1 unit 41E
1 1 13 65 -- 3RV2711-0JD10 1 1 unit 41E
1.25 1.25 16 65 -- 3RV2711-0KD10 1 1 unit 41E
1.6 1.6 21 65 -- 3RV2711-1AD10 1 1 unit 41E
2 2 26 65 -- 3RV2711-1BD10 1 1 unit 41E
2.5 2.5 33 65 -- 3RV2711-1CD10 1 1 unit 41E
3.2 3.2 42 65 -- 3RV2711-1DD10 1 1 unit 41E
4 4 52 65 -- 3RV2711-1ED10 1 1 unit 41E
5 5 65 65 -- 3RV2711-1FD10 1 1 unit 41E
6.3 6.3 82 65 -- 3RV2711-1GD10 1 1 unit 41E
8 8 104 65 -- 3RV2711-1HD10 1 1 unit 41E
10 10 130 65 -- 3RV2711-1JD10 1 1 unit 41E
12.5 12.5 163 65 -- 3RV2711-1KD10 1 1 unit 41E
15 15 208 65 -- 3RV2711-4AD10 1 1 unit 41E
Size S0
20 20 260 50 -- 3RV2721-4BD10 1 1 unit 41E
22 22 286 50 -- 3RV2721-4CD10 1 1 unit 41E
Size S33)
10 10 150 65 65 3RV2742-5AD10 1 1 unit 41E
15 15 225 65 65 3RV2742-5BD10 1 1 unit 41E
20 20 260 65 65 3RV2742-5CD10 1 1 unit 41E
25 25 325 65 65 3RV2742-5DD10 1 1 unit 41E
30 30 390 65 65 3RV2742-5ED10 1 1 unit 41E
35 35 455 65 -- 3RV2742-5FD10 1 1 unit 41E
40 40 520 65 -- 3RV2742-5GD10 1 1 unit 41E
45 45 585 65 -- 3RV2742-5HD10 1 1 unit 41E
50 50 650 65 -- 3RV2742-5JD10 1 1 unit 41E
60 60 780 65 -- 3RV2742-5LD10 1 1 unit 41E
70 70 910 65 -- 3RV2742-5QD10 1 1 unit 41E
1)
Rated value 100% according to UL 489 and IEC 60947-2 Lateral and transverse auxiliary switches can be ordered
("100% rated breaker"). separately (see from page 7/48 onwards).
2) Values for 600 Y/347 V AC, see page 7/17.
3)
Transverse auxiliary switches cannot be used for 3RV2742.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/45
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
For transformer protection according to UL 489/CSA C22.2 No. 5

■ Selection and ordering data


Without auxiliary switches
Circuit breakers for system and transformer protection according to UL/CSA,
specially designed for transformers with high inrush current

3RV2811-..D10 3RV2821-4.D10

Rated Thermal Instantaneous Short-circuit Screw terminals PU PS* PG


current1) overload release electronic release breaking capacity (UNIT,
(non-adjustable) at 480 Y/277 V AC2) SET, M)
In1) Ibc Article No. Price
per PU
A A A kA
Size S00
0.16 0.16 3.3 65 3RV2811-0AD10 1 1 unit 41E
0.2 0.2 4.2 65 3RV2811-0BD10 1 1 unit 41E
0.25 0.25 5.2 65 3RV2811-0CD10 1 1 unit 41E
0.32 0.32 6.5 65 3RV2811-0DD10 1 1 unit 41E
7

0.4 0.4 8.2 65 3RV2811-0ED10 1 1 unit 41E


0.5 0.5 10 65 3RV2811-0FD10 1 1 unit 41E
0.63 0.63 13 65 3RV2811-0GD10 1 1 unit 41E
0.8 0.8 16 65 3RV2811-0HD10 1 1 unit 41E
1 1 21 65 3RV2811-0JD10 1 1 unit 41E
1.25 1.25 26 65 3RV2811-0KD10 1 1 unit 41E
1.6 1.6 33 65 3RV2811-1AD10 1 1 unit 41E
2 2 42 65 3RV2811-1BD10 1 1 unit 41E
2.5 2.5 52 65 3RV2811-1CD10 1 1 unit 41E
3.2 3.2 65 65 3RV2811-1DD10 1 1 unit 41E
4 4 82 65 3RV2811-1ED10 1 1 unit 41E
5 5 104 65 3RV2811-1FD10 1 1 unit 41E
6.3 6.3 130 65 3RV2811-1GD10 1 1 unit 41E
8 8 163 65 3RV2811-1HD10 1 1 unit 41E
10 10 208 65 3RV2811-1JD10 1 1 unit 41E
12.5 12.5 260 65 3RV2811-1KD10 1 1 unit 41E
15 15 286 65 3RV2811-4AD10 1 1 unit 41E
Size S0
20 20 325 50 3RV2821-4BD10 1 1 unit 41E
22 22 364 50 3RV2821-4CD10 1 1 unit 41E
1)
Rated value 100% according to UL 489 and IEC 60947-2 Lateral and transverse auxiliary switches can be ordered
("100% rated breaker"). separately (see from page 7/48 onwards).
2) Values for 600 Y/347 V AC, see page 7/17.

* You can order this quantity or a multiple thereof.


7/46 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Mountable accessories

■ Overview
Mounting location and function
The 3RV2 motor starter protectors/circuit breakers have three These components are easily fitted to the switches without the
main contact elements. In order to achieve maximum flexibility, use of any tools according to requirements.
auxiliary switches, signaling switches, auxiliary releases and
isolator modules can be supplied separately. Overview graphic, see page 7/6.

Front side Transverse auxiliary An auxiliary switch can be inserted transversely on the front. The overall
Notes: switches, solid-state width of the motor starter protectors/circuit breakers remains unchanged.
compatible transverse
• A maximum of four auxiliary contacts with auxiliary switches
auxiliary switches can be mounted on each
motor starter protector/circuit breaker. 1 NO + 1 NC
or
• Transverse auxiliary switches cannot be used 2 NO
for circuit breaker 3RV2742 (size S3). or
1 CO
Left-hand side Lateral auxiliary switches One of the three lateral auxiliary switches can be mounted on the left side
Notes: (two contacts) per motor starter protector/circuit breaker. The contacts of the auxiliary
1 NO + 1 NC switch close and open together with the main contacts of the motor starter
• A maximum of four auxiliary contacts with protector/circuit breaker.
auxiliary switches can be mounted on each or
motor starter protector/circuit breaker. 2 NO The width of the lateral auxiliary switch with two contacts is 9 mm.
or
• Lateral auxiliary switches (two contacts) and 2 NC
signaling switches can be mounted separately
or together. Lateral auxiliary switches One lateral auxiliary switch with four contacts can be mounted on the left
(four contacts) side per motor starter protector/circuit breaker. The contacts of the auxiliary
• Signaling switches cannot be used for
2 NO + 2 NC switch close and open together with the main contacts of the motor starter
3RV1011, 3RV27 and 3RV28 motor starter
protector/circuit breaker.
protectors/circuit breakers.
The width of the lateral auxiliary switch with four contacts is 18 mm.
• Only lateral auxiliary switches can be used for

7
3RV2742 (size S3). Signaling switches One signaling switch can be mounted on the left side of each motor starter
Tripping 1 NO + 1 NC protector.
Short circuit 1 NO + 1 NC The signaling switch has two contact systems.
One contact system always signals tripping irrespective of whether this was
caused by a short circuit, an overload or an auxiliary release. The other
contact system only switches in the event of a short circuit. There is no
signaling as a result of switching off with the actuator.
In order to be able to switch on the motor starter protector again after a short
circuit, the signaling switch must be reset manually after the error cause has
been eliminated.
The width of the signaling switch is 18 mm.
Right-hand side Auxiliary releases
Notes: Shunt releases For remote-controlled tripping of the motor starter protector/circuit breaker.
• One auxiliary release can be mounted per The release coil should only be energized for short periods (see circuit
motor starter protector/circuit breaker. diagrams).
• Accessories cannot be mounted on the right- or
hand side of the 3RV21 motor starter protectors
for motor protection with overload relay Undervoltage releases Trips the motor starter protector/circuit breaker when the voltage is
function. interrupted and prevents the motor from being restarted accidentally when
the voltage is restored. Used for remote-controlled tripping of the motor
starter protector/circuit breaker.
Particularly suitable for EMERGENCY OFF disconnection by way of
corresponding EMERGENCY OFF pushbuttons according to IEC 60204-1.
or
Undervoltage releases with Function and use as for the undervoltage release without leading auxiliary
leading auxiliary contacts 2 NO contacts, but with the following additional function: the auxiliary contacts will
Own version for 3RV1011 open in switch position OFF to deenergize the coil of the undervoltage
release, thus interrupting energy consumption. In the "tripped" position,
these auxiliary contacts are not guaranteed to open. The leading contacts
permit the motor starter protector/circuit breaker to reclose.
The width of the auxiliary release is 18 mm.
Top Isolator modules Isolator modules can be mounted to the upper connection side of the motor
Notes: starter protectors.
• Isolator modules cannot be used for 3RV1011, The supply cable is connected to the motor starter protector through the
3RV27 and 3RV28 motor starter protectors/ isolator module.
circuit breakers. The plug can only be unplugged when the motor starter protector is open
• The isolator module for size S2 can be used and isolates all 3 poles of the motor starter protector from the network.
only with 3RV2 motor starter protectors/ The shock-protected isolation point is clearly visible and secured with
circuit breakers up to max. 65 A. a padlock to prevent reinsertion of the plug.
• The isolator module cannot be used with the
transverse auxiliary switch.

For a complete overview of which accessories can be used for the


various motor starter protectors/circuit breakers, see page 7/2.

Siemens IC 10 · 2023 7/47


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Mountable accessories

■ Selection and ordering data


PU (UNIT, SET, M) = 1
PS* = 1 unit (unless otherwise specified)
PG = 41E
Version For motor Screw terminals Spring-loaded
starter terminals
protectors/
circuit
breakers
Article No. Price Article No. Price
Size per PU per PU

Auxiliary switches1)
Transverse auxiliary switches2)
For front mounting
1 CO S00 ... S3 3RV2901-1D --
1 NO + 1 NC 3RV2901-1E 3RV2901-2E
3RV2901-1E 2 NO 3RV2901-1F 3RV2901-2F
Solid-state compatible
transverse auxiliary
switches2)
3RV2901-2E For mounting on the front,
for operation in dusty
atmosphere and in solid-
state circuits with low
operating currents
3RV2901-1G 1 CO S00 ... S3 3RV2901-1G --
Covers for transverse S00 ... S3 3RV2901-0H --
auxiliary switches
7

(PS* = 10 units)

3RV2901-0H
Lateral auxiliary switches
For mounting on the left
1 NO + 1 NC S00 ... S3 3RV2901-1A 3RV2901-2A
2 NO 3RV2901-1B 3RV2901-2B
2 NC 3RV2901-1C 3RV2901-2C
2 NO + 2 NC 3RV2901-1J --

3RV2901-1A 3RV2901-2A
Signaling switches3)
Signaling switches S005) ... S3 3RV2921-1M 3RV2921-2M
One signaling switch can be
mounted on the left per motor
starter protector.
Separate tripped and
short-circuit alarms,
1 NO + 1 NC each

3RV2921-1M 3RV2921-2M
Isolator modules3)4)
Isolator modules S005), S0 3RV2928-1A --
Visible isolating distance for S2 3RV2938-1A --
isolating individual motor
starter protectors from the
network, lockable in
disconnected position

3RV2928-1A 3RV2938-1A
1) 3)
Each motor starter protector/circuit breaker can be fitted with one This accessory cannot be used for the 3RV27 and 3RV28 circuit breakers
transverse and one lateral auxiliary switch. The lateral auxiliary switch (sizes S00, S0, S3).
with 2 NO + 2 NC is used without a transverse auxiliary switch. 4)
The isolator module for size S2 can be used only with 3RV2 motor starter
2)
Not for 3RV2742 circuit breakers. protectors/circuit breakers up to max. 65 A. Similarly, it cannot be used
with the transverse auxiliary switch
5) Not for 3RV1011 motor starter protectors.

* You can order this quantity or a multiple thereof.


7/48 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Mountable accessories
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41E

3RV2902-1AV0 3RV2902-2AV0 3RV2922-1CP0 3RV2902-2DB0

Rated control supply voltage Us For motor Screw terminals Spring-loaded


AC AC AC AC/DC DC starter terminals
50 Hz 60 Hz 50/60 Hz 50/60 Hz, protectors/
DC circuit
100% ON period 5 s ON period2)
1) breakers
Article No. Price Article No. Price
V V V V V Size per PU per PU

Auxiliary releases3)
Undervoltage releases
-- -- -- -- 24 S00 ... S3 3RV2902-1AB4 --
24 24 -- -- -- S00 ... S3 3RV2902-1AB0 --
110 120 -- -- -- S00 ... S3 3RV2902-1AF0 --
-- 208 -- -- -- S00 ... S3 3RV2902-1AM1 --
230 240 -- -- -- S00 ... S3 3RV2902-1AP0 3RV2902-2AP0

7
400 440 -- -- -- S00 ... S3 3RV2902-1AV0 3RV2902-2AV0
415 480 -- -- -- S00 ... S3 3RV2902-1AV1 --
500 600 -- -- -- S00 ... S3 3RV2902-1AS0 --
Undervoltage releases with leading auxiliary contacts 2 NO
24 24 -- -- -- S004) ... S3 3RV2922-1CB0 --
230 240 -- -- -- S004) ... S3 3RV2922-1CP0 3RV2922-2CP0
400 440 -- -- -- S004) ... S3 3RV2922-1CV0 3RV2922-2CV0
415 480 -- -- -- S004) ... S3 3RV2922-1CV1 3RV2922-2CV1
Shunt releases
-- -- 20 ... 24 20 ... 70 -- S00 ... S3 3RV2902-1DB0 3RV2902-2DB0
-- -- 90 ... 110 70 ... 190 -- S00 ... S3 3RV2902-1DF0 3RV2902-2DF0
-- -- 210 ... 240 190 ... 330 -- S00 ... S3 3RV2902-1DP0 3RV2902-2DP0
-- -- 350 ... 415 330 ... 500 -- S00 ... S3 3RV2902-1DV0 --
-- -- 500 500 -- S00 ... S3 3RV2902-1DS0 --
1) 3)
The voltage range is valid for 100% (infinite) ON period. The response One auxiliary release can be mounted on the right per motor starter
voltage lies at 0.9 of the lower limit of the voltage range. protector/circuit breaker (does not apply to 3RV21 motor starter
2) The voltage range is valid for 5 s ON period at 50/60 Hz AC and DC. protectors/circuit breakers with overload relay function).
The response voltage lies at 0.85 of the lower limit of the voltage range. 4)
Not for 3RV1011 motor starter protectors.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/49
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Busbar accessories

■ Overview
Insulated 3-phase busbar system The 3-phase busbar systems can also be used to construct
"Starters (Type E)" according to UL/CSA and for 3RV27 and
3-phase busbar systems provide an easy, time-saving 3RV28 circuit breakers according to UL 489. However,
and clearly arranged means of feeding 3RV2 motor starter special infeed terminals, 3RV2925-5EB for sizes S00/S0
protectors/circuit breakers with screw terminals. Different and 3RV2935-5E for size S2, must be used for this purpose,
versions are available for sizes S00 to S2 and can be used for see page 7/52.
the different types of motor starter protectors/circuit breakers
(size S0 up to 32 A). 8US busbar adapters for 60 mm systems
The 3RV1915 3-phase busbar systems are generally unsuitable The motor starter protectors/circuit breakers are mounted
for the 3RV21 motor starter protectors with sizes S00 and S0 for directly with the aid of busbar adapters on busbar systems with
motor protection with overload relay function. 60 mm center-to-center clearance in order to save space and to
The busbars are suitable for between two and five motor starter reduce infeed times and costs.
protectors/circuit breakers. However, any kind of extension is Busbar adapters for busbar systems with 60 mm center-to-
possible by clamping the connection tags of an additional center clearance are suitable for copper busbars with a width of
busbar (rotated by 180°) underneath the terminals of the 12 mm to 30 mm. The busbars can be 5 mm or 10 mm thick.
respective last motor starter protector/circuit breaker.
The motor starter protectors/circuit breakers are snapped onto
A combination of motor starter protectors/circuit breakers of the adapter and connected on the line side. This prepared unit
size S00 and S0 is possible. The motor starter protectors/ is then plugged directly onto the busbar system, and is thus
circuit breakers are supplied by appropriate infeed terminals. connected both mechanically and electrically at the same time.
For the setup of UL feeders (Type E and F), Type E terminal
3RV2925-5AB blocks or phase barriers must be fitted to the infeed module on
the motor starter protector (see from page 7/57).
3RV1915-1CB
For further busbar adapters for snap-mounting direct-on-line
starters and reversing starters as well as additional accessories
7

such as line terminals and outgoing terminals, flat copper profile,


etc., see Catalog LV 10.

3RV2915-5B
NSB0_02079c

3RV1915-6AB

SIRIUS 3-phase busbar system size S00/S0

3RV2935-5A 3RV1935-1C

3RV1935-1A
NSB0_02080a
NSB0_01074e

SIRIUS load feeders with busbar adapters snapped onto busbars

3RV1935-6A

SIRIUS 3-phase busbar system size S2


The 3-phase busbar systems are finger-safe. They are designed
for any short-circuit stress which can occur at the output side of
connected motor starter protectors/circuit breakers.

7/50 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Busbar accessories

■ Selection and ordering data


Modular Number of motor starter Rated For motor Article No. Price PU PS* PG
spacing protectors that can be current In starter per PU (UNIT,
connected at 690 V protectors/ SET, M)
without with lateral incl. circuit
lateral auxiliary auxiliary breakers
acces- switch release
sories
mm A Size
3-phase busbars
For feeding several motor starter protectors with screw terminals,
mounted side by side on DIN rails, insulated, with touch protection
3RV1915-1AB 451)2) 2 -- -- 63 S00, S03) 3RV1915-1AB 1 1 unit 41E
3 -- -- 63 S00, S03) 3RV1915-1BB 1 1 unit 41E
4 -- -- 63 S00, S03) 3RV1915-1CB 1 1 unit 41E
5 -- -- 63 S00, S03) 3RV1915-1DB 1 1 unit 41E
551)4) -- 2 -- 63 S00, S03) 3RV1915-2AB 1 1 unit 41E
3RV1915-1BB -- 3 -- 63 S00, S03) 3RV1915-2BB 1 1 unit 41E
-- 4 -- 63 S00, S03) 3RV1915-2CB 1 1 unit 41E
-- 5 -- 63 S00, S03) 3RV1915-2DB 1 1 unit 41E
2 -- -- 108 S2 3RV1935-1A 1 1 unit 41E
3RV1915-1CB 3 -- -- 108 S2 3RV1935-1B 1 1 unit 41E
4 -- -- 108 S2 3RV1935-1C 1 1 unit 41E
631)5) -- -- 2 63 S00, S03) 3RV1915-3AB 1 1 unit 41E
-- -- 4 63 S00, S03) 3RV1915-3CB 1 1 unit 41E
3RV1915-1DB 755) -- 2 2 108 S2 3RV1935-3A 1 1 unit 41E
-- 3 3 108 S2 3RV1935-3B 1 1 unit 41E
-- 4 4 108 S2 3RV1935-3C 1 1 unit 41E

7
1) 4)
Not suitable for 3RV21 motor starter protectors of sizes S00 and S0 with For 3RV2 motor starter protectors with auxiliary switches with 1 NO + 1 NC,
overload relay function. 2 NO and 2 NC mounted on the left (9 mm wide).
2) 5)
For 3RV2 motor starter protectors without accessories mounted on the side. For 3RV20, 3RV21, 3RV23 and 3RV24 motor starter protectors with
3) Approved for motor starter protectors size S0 with I  32 A. mounted accessories (18 mm wide). Auxiliary switches with 2 NO + 2 NC
n
or signaling switch (mounted on the left) or with auxiliary release (mounted
on the right).

Version Modular For motor starter Article No. Price PU PS* PG


spacing protectors/ per PU (UNIT,
circuit breakers SET, M)
mm Size
Connecting pieces for 3-phase busbars
For connecting 3-phase busbars 45 S00, S0 3RV1915-5DB 1 1 unit 41E
for 3RV2 motor starter protectors of
size S00/S0 (left) to the 3RV1011
3RV1915-5DB motor starter protector (right)

Conductor cross-section Tightening For motor Article No. Price PU PS* PG


Solid or Finely AWG cables, torque starter per PU (UNIT,
stranded stranded solid or protectors/ SET, M)
with end stranded circuit
sleeve breakers
mm² mm² AWG Nm Size
3-phase infeed terminals
Connection from top
2.5 … 25 4 ... 16 10 ... 4 4 S002), S0 3RV1915-5A 1 1 unit 41E
2.5 … 25 2.5 … 16 10 ... 4 3 ... 4 S00, S0 3RV2925-5AB 1 1 unit 41E
3RV2925-5AB 2x 2x 2x 4 ... 6 S2 3RV2935-5A 1 1 unit 41E
(2.5 ... 50)1), (2.5 ... 35)1), (10 ... 1/0)1),
1x 1x 1x
(2.5 ... 70)1) (2.5 ... 50)1) (10 ... 2/0)1)

3RV2935-5A
Connection from below
Terminal is connected in place of a switch, take space
requirement into account
2.5 … 25 2.5 … 16 10 ... 4 Input: S00, S0 3RV2915-5B 1 1 unit 41E
4,
output:
3RV2915-5B 2 ... 2.5
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must be in the range specified.
2) Especially suitable for 3RV1011 motor starter protectors. If the 3RV2 motor
starter protector is used, the terminal block extends beyond the device
width.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/51
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Busbar accessories

Conductor cross-section Tightening For motor Article No. Price PU PS* PG


Solid or Finely AWG cables, torque starter per PU (UNIT,
stranded stranded solid or protectors/ SET, M)
with end stranded circuit
sleeve breakers
mm² mm² AWG Nm Size
3-phase infeed terminals for constructing "starters (Type E)"
Connection from top
2.5 … 25 2.5 … 16 10 ... 4 3 ... 4 S00, S0 3RV2925-5EB 1 1 unit 41E
2x 2x 2x 4 ... 6 S2 3RV2935-5E 1 1 unit 41E
(2.5 ... 50)1), (2.5 ... 35)1), (10 ... 1/0)1),
1x 1x 1x
3RV2925-5EB (2.5 ... 70)1) (2.5 ... 50)1) (10 ... 2/0)1)

3RV2935-5E
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must be in the range specified.

Version For motor starter Article No. Price PU PS* PG


protectors/ per PU (UNIT,
circuit breakers SET, M)
Size
Covers for connection tags
Touch protection for empty positions S00, S0 3RV1915-6AB 1 10 units 41E
7

S2 3RV1935-6A 1 5 units 41E


3RV1935-6A covers
mounted on
3RV1915-1CB busbar

* You can order this quantity or a multiple thereof.


7/52 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Busbar accessories
Busbar adapters

8US1251-5DS10 8US1251-5DT11 8US1211-4TR00 8US1250-5AS10 8US1250-5AT10

For motor starter Rated current Connecting Adapter Adapter Rated voltage Article No. Price PU PS* PG
protectors/ cable length width per PU (UNIT,
circuit breakers SET, M)
Size A AWG mm mm V
Busbar adapters for 60 mm systems
For copper busbars according to DIN 46433
Width: 12 mm and 30 mm
Thickness: 5 mm and 10 mm
and for T and double-T special profiles
• For motor starter protectors/circuit breakers with screw terminals1) Screw terminals

S002), S03) 25 12 200 45 690 8US1251-5DS10 1 1 unit 14O


S002), S0 25 12 260 45 690 8US1251-5DT10 1 1 unit 14O
S0 32 10 200 45 690 8US1251-5NS10 1 1 unit 14O
S03) 32 10 260 45 690 8US1251-5NT10 1 1 unit 14O
S2 80 4 200 55 690 8US1261-5MS13 1 1 unit 14O

7
S2 80 4 260 55 690 8US1261-6MT10 1 1 unit 14O
S24) 80 4 260 118 690 8US1211-6MT10 1 1 unit 14O
S3 100/705) 4 215 72 690/6005) 8US1211-4TR00 1 1 unit 14O
• For motor starter protectors/circuit breakers with spring-loaded terminals6) Spring-loaded
terminals
S002), S03) 25 12 200 45 690 8US1251-5DS11 1 1 unit 14O
S002), S03) 25 12 260 45 690 8US1251-5DT11 1 1 unit 14O
S0 32 10 200 45 690 8US1251-5NS11 1 1 unit 14O
S03) 32 10 260 45 690 8US1251-5NT11 1 1 unit 14O
Accessories
Device holders -- -- 200 45 -- 8US1250-5AS10 1 1 unit 14O
For lateral attachment -- -- 260 45 -- 8US1250-5AT10 1 1 unit 14O
to busbar adapters
Side modules -- -- 200 9 -- 8US1998-2BJ10 1 10 units 14O
For widening busbar
adapters
Vibration and
shock kits
For high vibration
and shock loads
S2 -- -- -- -- -- 8US1998-1DA10 1 1 unit 14O
1) For the setup of UL feeders (Type E and F), Type E terminal blocks or For additional busbar adapters and accessories, see
phase barriers (for sizes S00 to S2) must be fitted to the infeed module Catalog LV 10.
on the motor starter protector (see from page 7/57).
2)
Not for 3RV1011 motor starter protectors.
3)
Also approved for 3RV27, 3RV28 circuit breakers according to UL.
4) For the assembly of feeders for reversing starters consisting of a motor
starter protector and two contactors.
5)
Values according to UL/CSA:
- Rated current: 70 A at 600 V AC
- Short-circuit breaking capacity:
480 V AC: 65 kA, up to In = 30 A,
480 Y/277 V AC: 65 kA,
600 Y/347 V AC: 20 kA.
6) It is not possible to set up UL feeders (Type E and F).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/53
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Rotary operating mechanisms

■ Overview
Door-coupling rotary operating mechanisms
3RV2926-1B door-coupling rotary operating
Motor starter protectors/circuit breakers with a rotary operating
mechanism for sizes S00 to S3
mechanism can be mounted in a control cabinet and operated
externally by means of a door-coupling rotary operating Consisting of:
mechanism. When the cabinet door with motor starter 1 Actuator
protector/circuit breaker is closed, the operating mechanism 2 Plastic cover
is coupled. When the motor starter protector/circuit breaker
3 Coupling driver

IC01_00711
closes, the coupling is locked which prevents the door from
being opened unintentionally. This interlock can be defeated 4 Extension shaft (6 mm x 6 mm),
130 mm long
by the maintenance personnel. In the OFF position, the rotary
operating mechanism can be secured against reclosing with 5 Coupling enclosure
up to three padlocks. Inadvertent opening of the door is not
possible in this case either. 6 Control cabinet door 5

With the optional 3RV2926-.Q tolerance compensation, an offset 4


can be compensated when installing the door-coupling rotary
operating mechanism. For this purpose, the standard coupling 3
head on the shaft is removed and replaced by the tolerance
compensation.
2

1
Video: SIRIUS door-coupling rotary mechanism
7

SIRIUS 3RV2926-1B door-coupling rotary operating mechanism

3RV2926-3B door-coupling rotary operating

IC01_00712
mechanism for sizes S00 and S0
Consisting of:
1 Actuator
2 Plastic cover
3 Coupling driver 6
4 Extension shaft (8 mm x 8 mm),
300 mm long
5 Spacer
5
6 Metal brackets for inserting
motor starter protector/circuit
breaker
4
7 Control cabinet door

7
1

SIRIUS 3RV2926-3B door-coupling rotary operating mechanism for harsh


conditions

7/54 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Rotary operating mechanisms
Door-coupling rotary operating mechanism for mounting
one main switch in size S3 according to UL 508A and 3RV2946-3C EMERGENCY OFF door-coupling rotary operating
NFPA 79 mechanism for size S3
For the installation of a door-coupling rotary operating Consisting of:
mechanism for harsh conditions for a main switch (only possible 1 Actuator
in size S3) in a UL control cabinet (according to UL 508A and 2 Plastic cover
NFPA 79), the standard stipulates a second handle in the control 3 Coupling driver
cabinet. With the cabinet door open, it shall only be possible to
4 Extension shaft (8 mm x 8 mm), 300 mm long
switch on this supplementary handle by means of a "deliberate
action". 5 Spacer

IC01_00713
6 Metal brackets for inserting
The figure below shows the setup required for this purpose, motor starter protector/circuit breaker
with the 3RV2946-3C door-coupling rotary operating
mechanism for harsh conditions, the 3RV2926-0P shaft 7 Control cabinet door
support, and the 3VA9137-0GC05 supplementary handle 6
(EMERGENCY OFF version). Required for assembly of main control
switch in accordance with UL 508A
To switch on the supplementary handle, the handle must be
and NFPA 79
pressed against a spring in the direction of the mounting plane. (can be optionally ordered):
This is the required "deliberate action" so that the supplementary 8
8 3RV2926-0P shaft support
handle does not turn empty and the circuit breaker can
be closed. 9 3VA9137-0GC05 9
supplementary handle 5
(EMERGENCY OFF
version)
4

7
2

SIRIUS 3RV2946-3C EMERGENCY OFF door-coupling rotary operating


mechanism for harsh operating conditions according to UL 508A and
NFPA 79 with optional shaft support and supplementary handle
(EMERGENCY OFF version)

■ Selection and ordering data


Version Color of Version of For motor starter Article No. Price PU PS* PG
actuator extension shaft protectors/ per PU (UNIT,
circuit breakers SET, M)
mm Size
Door-coupling rotary operating mechanisms
The door-coupling rotary operating mechanisms consist of an actuator, a coupling driver and a 130/330 mm long extension shaft
(6 mm x 6 mm).
The door-coupling rotary operating mechanisms are dimensioned for degree of protection IP64. For UL/CSA applications, they are
tested for enclosure types 1, 3R and 12. The door interlocking prevents accidental opening of the control cabinet door in the
ON position of the motor starter protector. The OFF position can be locked with up to three padlocks.
With the optional 3RV2926-0Q tolerance compensation, an offset can be compensated when installing the door-coupling rotary
operating mechanism.
Door-coupling Gray 130 S001) ... S3 3RV2926-1B 1 1 unit 41E
rotary 330 S001) ... S3 3RV2926-1K 1 1 unit 41E
3RV2926-1B operating
mechanisms
EMERGENCY Red/ 130 S001) ... S3 3RV2926-1C 1 1 unit 41E
OFF door- yellow 330 S001) ... S3 3RV2926-1L 1 1 unit 41E
coupling
rotary
operating
mechanisms

3RV2926-1C
Optional accessories
Tolerance -- -- -- 3RV2926-0Q 1 1 unit 41E
compensation

3RV2926-0Q
1)
Not for 3RV1011 motor starter protectors.
* You can order this quantity or a multiple thereof.
Illustrations are approximate Siemens IC 10 · 2023 7/55
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Rotary operating mechanisms

Version Color of Version of For motor starter Article No. Price PU PS* PG
actuator extension shaft protectors/ per PU (UNIT,
circuit breakers SET, M)
mm Size
Door-coupling rotary operating mechanisms for harsh conditions
The door-coupling rotary operating mechanisms consist of an actuator, a coupling driver, an extension shaft of 300 mm in length
(8 mm x 8 mm), a spacer and two metal brackets, into which the motor starter protector/circuit breaker is inserted.
The door-coupling rotary operating mechanisms are designed to degree of protection IP65. For UL/CSA applications, they are
tested for enclosure types 1, 3R and 12. The door interlocking reliably prevents opening of the control cabinet door in the
ON position of the motor starter protector/circuit breaker. The OFF position can be locked with up to three padlocks.
Laterally mountable auxiliary releases and 2-pole auxiliary switches can be used.
The door-coupling rotary operating mechanisms thus meet the requirements for isolating functions according to IEC 60947-2.
With the optional 3RV2926-2Q tolerance compensation, an offset can be compensated when installing the door-coupling rotary
operating mechanism for harsh conditions.
Door-coupling Gray 300 S001), S0 3RV2926-3B 1 1 unit 41E
3RV2946-3B
rotary S2 3RV2936-3B 1 1 unit 41E
operating
mechanisms S3 3RV2946-3B 1 1 unit 41E
EMERGENCY Red/ 300 S001), S0 3RV2926-3C 1 1 unit 41E
OFF door- yellow S2 3RV2936-3C 1 1 unit 41E
coupling
rotary S3 3RV2946-3C 1 1 unit 41E
operating
mechanism

3RV2946-3C
Optional accessories
Tolerance -- -- S00 ... S3 3RV2926-2Q 1 1 unit 41E
7

compensation

3RV2926-2Q
Necessary accessories for mounting one main switch in size S3 according to UL 508A and NFPA 79
(see also page 7/55)
Shaft supports -- -- S00 ... S3 3RV2926-0P 1 1 unit 41E

3RV2926-0P
Supplementary handles
• Standard Gray -- S3 3VA9137-0GC01 1 1 unit 12P

3VA9137-0GC01
• EMERGENCY Red/ -- S3 3VA9137-0GC05 1 1 unit 12P
OFF yellow

3VA9137-0GC05
1) Not for 3RV1011 motor starter protectors.

* You can order this quantity or a multiple thereof.


7/56 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Mounting accessories

■ Overview
More information
System Manual for modular system, see Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60311318 https://support.industry.siemens.com/cs/ww/en/view/60279172

Accessories for "Self-Protected Combination Motor


Controllers (Type E)" according to UL 508/UL 60947-4-1 Motor starter Size Essential accessories
protectors/ for "Self-Protected Combination
The 3RV20 motor starter protectors with screw terminals are circuit breakers Motor Controllers (Type E)"
approved according to UL 508/UL 60947-4-1 as "Self-Protected according to UL 508/UL 60947-4-1
Combination Motor Controllers (Type E)". 3RV201., 3RV202. S00/S0 3RV2928-1H terminal block or
The 3RV1011 motor starter protectors do not have this 3RV2928-1K phase barrier
UL approval. 3RV2031-4B.1., S2 --
3RV2031-4D.1.,
This requires increased clearance and creepage distances 3RV2031-4E.1.,
(1 inch and 2 inches respectively) at the input side of the device, 3RV2031-4P.1.,
which are achieved by mounting a terminal block or a phase 3RV2031-4S.1.,
3RV2031-4T.1.,
barrier. No transverse auxiliary switches may be used when 3RV2031-4U.1.,
using 3RT2946-4GA07 terminal blocks for size S3. 3RV2031-4V.1.
3RV2031-4J.1., S2 3RV2938-1K phase barrier
3RV2031-4K.1.,
3RV2031-4R.1.,
3RV2031-4W.1.,
3RV2031-4X.1.,
c
379 3RV2032
_01
B0
NS
3RV204. S3 3RT2946-4GA07 terminal block
-- No accessories needed
SIRIUS 3RV2928-1H terminal block
Special 3-phase infeed terminals are required for constructing

7
"Starters (Type E)" with an insulated 3-phase busbar system
(see "Busbar accessories", page 7/52).
NSB0_01380c

For the setup of "Starters (Type E)" with 8US busbar adapters,
Type E terminal blocks or phase barriers (for sizes S00 to S2)
must be fitted to the infeed module on the motor starter
protector/circuit breaker, see page 7/60.
The 3RV29 infeed system also enables the assembly of
"Starters (Type E)", see page 7/67 onwards.
SIRIUS 3RT2946-4GA07 terminal block (Type E)
Note:
According to CSA, these terminal blocks and the phase barriers
can be omitted when the device is used as a "Self-Protected
Combination Motor Controller (Type E)".
8
40
00
1_
IC0

SIRIUS 3RV2928-1K phase barrier

Siemens IC 10 · 2023 7/57


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Mounting accessories
Link modules
Feeders can be easily assembled from single devices with the
help of the link modules. The following table shows the different
combination options for devices with screw or spring-loaded
terminals.
Combination 3RV2 motor starter 3RT2 contactors; Link modules
devices protectors/ 3RW30, 3RW40 soft starters; Screw terminals Spring-loaded terminals
circuit breakers 3RF34 solid-state contactors
Size Size
Link modules
for connecting switching devices to 3RV2 motor starter protectors/circuit breakers1)
3RT2 contactors with AC or DC coil S00 S00 3RA1921-1DA00 3RA2911-2AA00
S0 S00 --
S2 S2 3RA2931-1AA00 --
S32) S32) 3RA1941-1AA00 --
3RT2 contactors with AC coil S00 S0 3RA2921-1AA00 --
S0 S0 3RA2921-2AA003)
3RT2 contactors with DC or AC/DC coil S00 S0 3RA2921-1BA00 --
S0 S0 3RA2921-2AA00
3RW30 soft starters S00 S00 3RA2921-1BA00 3RA2911-2GA00
S0 S00 --
3RW30/3RW40 soft starters S00 S0 3RA2921-1BA00 --
S0 S0 3RA2921-2GA00
S24) S24) 3RA2931-1AA00 --
S35) S35) 3RA1941-1AA00 --
7

3RF34 solid-state contactors S00/S0 S00 3RA2921-1BA00 --


Hybrid link modules
for connecting contactors with spring-loaded terminals to 3RV2 motor starter protectors/circuit breakers with screw terminals6)
3RT2 contactors with AC or DC coil S00 S00 3RA2911-2FA00 --
S0 S0 3RA2921-2FA00 --
-- Version not possible Notes:
1) The link modules cannot be used for 3RV2.21-4PA1., 3RV2.21-4FA1., • Link modules can be used in
3RV2.31-4K.1., 3RV2.31-4R.1., 3RV2.32-4K.1., 3RV2.32-4R.1., 3RV27,
3RV28 and 3RV1011 motor starter protectors/circuit breakers.
- Size S00: up to max. 16 A
2)
To assemble the feeder between a motor starter protector and a contactor
- Size S0: up to max. 32 A
in size S3, the 3RA2942-1AA00 DIN-rail adapter must be used. - Size S2: up to max. 65 A
3)
A spacer for height compensation on AC contactors, size S0, is optionally • Hybrid link modules can be used in
available, see page 7/61. - Size S00: up to max. 16 A
4) To assemble the feeder between a motor starter protector and a soft starter - Size S0: up to max. 32 A
in size S2, the 3RA2932-1CA00 DIN-rail adapter must be used.
5)
It is only permissible to assemble the feeder between the motor starter
protector and the soft starter in size S3 on a mounting plate.
6)
The hybrid link modules for motor starter protector to contactor cannot be
used for 3RV2.21-4PA1., 3RV2.21-4FA1., 3RV27 and 3RV28 motor starter
protectors/circuit breakers. They are suitable only for constructing direct-
on-line starters.

7/58 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Mounting accessories

■ Selection and ordering data


Accessories
Version For motor starter Article No. Price PU PS* PG
protectors/ per PU (UNIT,
circuit breakers SET, M)
Size
Covers
Terminal covers S3 3RT1946-4EA1 1 1 unit 41B
For cable lug and busbar connection for
maintaining the required voltage clearances
and as touch protection if box terminal is
removed (two units can be mounted per
motor starter protector/circuit breaker)

3RV2 (size S3) with


3RT1946-4EA1 (below)
Scale covers 3RV20, 3RV21, 3RV2908-0P 100 10 units 41E
Sealable, 3RV24:
for covering the set current scale S00 ... S3
3RV2908-0P
Covers for devices with screw terminals Screw terminals
(box terminals)
Additional touch protection to be fitted at the
box terminals (two units required per device)
Main current level S2 3RT2936-4EA2 1 1 unit 41B
3RT2936-4EA2

7
S3 3RT2946-4EA2 1 1 unit 41B
Terminal covers for box terminals on 3RV2742 and
Type E terminal block 3RT2946-4GA07
Additional touch protection to be fitted at the
3RV2742 box terminals (two units required
per device) and at 3RT2946-4GA07 terminal
block (Type E)
Main current level S3 3RV2948-1LA00 1 1 unit 41E

3RV2948-1LA00
Phase barrier for constructing limiter combinations of size S31)
Infeed to the limiter is always on the side
2T1/4T2/6T3. Use 3RV2948-1K phase
barriers on the infeed side.
Main current level S3 3RV2948-1K 1 1 unit 41E

3RV2948-1K
Fixing accessories
Push-in lugs S00, S0 3RV2928-0B 100 10 units 41E
For screw fixing of the motor starter protector/
circuit breaker onto mounting plates
Two units are required for each motor starter
3RV2928-0B protector.
Tools for opening spring-loaded terminals
Screwdrivers Spring-loaded
For all SIRIUS devices with spring-loaded terminals terminals
Length approx. 200 mm, 3.0 mm x 0.5 mm, S00 ... S3 3RA2908-1A 1 1 unit 41B
titanium gray/black, partially insulated
3RA2908-1A
Blank labels
Unit labeling plates1) S00 ... S3 3RT2900-1SB20 100 340 41B
For SIRIUS devices, units
20 mm x 7 mm, titanium gray
Adhesive labels S00 ... S3 3RT2900-1SB60 100 3 060 41B
IC01_00181

For SIRIUS devices, units


19 mm x 6 mm, titanium gray
3RT2900-1SB20
1)
PC labeling system for individual inscription of
unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/59
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Mounting accessories

Version For motor starter Article No. Price PU PS* PG


protectors/ per PU (UNIT,
circuit breakers SET, M)
Size
Terminal blocks and phase barriers for "Self-Protected
Combination Motor Controllers (Type E)" according to UL 508/UL 60947-4-1
Note:
UL 508/UL 60947-4-1 approval demands 1-inch clearance and 2-inch creepage distances for "Self-Protected Combination Motor
Controllers (Type E)". The following terminal blocks or phase barriers must be used for the 3RV20 motor starter protectors with screw
terminals. This also applies to construction with the 8US busbar adapter. 3RV20 motor starter protectors with spring-loaded terminals
must be assembled with the 3RV29 infeed system for approval as "Self-Protected Combination Motor Controllers (Type E)" according to
UL 508/UL 60947-4-1. The 3RV1011 motor starter protectors do not have UL approval as "Starters (Type E)".
3RV2928-1H The terminal block or phase barriers cannot be used in combination with the 3RV19.5 3-phase busbars.
For construction with 3-phase busbars, see "Busbar Accessories", from page 7/50 onwards.
Terminal blocks Type E S001), S0 3RV2928-1H 1 1 unit 41E
For increased clearance and creepage S32) 3RT2946-4GA07 1 1 unit 41B
distances (1 and 2 inch)
3RT2946-4GA07 Phase barriers S001), S0 3RV2928-1K 1 1 unit 41E
For increased clearance and creepage S2 3RV2938-1K 1 1 unit 41E
distances (1 and 2 inch)

3RV2928-1K
7

3RV2938-1K
Auxiliary conductor terminals, 3-pole
For connection of auxiliary and control S3 3RT2946-4F 1 1 unit 41B
cables to the main conductor connections
(for one side)

3RT2946-4F
1)
Not for 3RV1011 motor starter protectors.
2) Cannot be used on 3RV2.4. motor starter protectors in combination with
transverse auxiliary switches.

* You can order this quantity or a multiple thereof.


7/60 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Mounting accessories
Link modules
For For Actuating voltage of Article No. Price PU PS* PG
3RV2 motor starter 3RT2 contactor per PU (UNIT,
protectors/ contactors SET, M)
circuit breakers
Size Size
Link modules for motor starter protector to contactor1)
For connection between Screw terminals
motor starter protector and contactor with screw terminals
Single-unit packaging
S00/S0 S00 AC, DC 3RA1921-1DA00 1 1 unit 41B
S00/S0 S0 AC 3RA2921-1AA00 1 1 unit 41B
S00/S0 S0 DC, AC/DC 3RA2921-1BA00 1 1 unit 41B
3RA2921-1AA00 S2 S2 AC, DC, AC/DC 3RA2931-1AA00 1 1 unit 41B
S3 S3 AC, DC, AC/DC 3RA1941-1AA00 1 1 unit 41B
Multi-unit packaging
S00/S0 S00 AC, DC 3RA1921-1D 1 10 units 41B
S00/S0 S0 AC 3RA2921-1A 1 10 units 41B
S00/S0 S0 DC, AC/DC 3RA2921-1B 1 10 units 41B
S2 S2 AC, DC, AC/DC 3RA2931-1A 1 5 units 41B
S3 S3 AC, DC, AC/DC 3RA1941-1A 1 5 units 41B

3RA2931-1AA00

7
3RA1941-1AA00
For connection between Spring-loaded
motor starter protector and contactor with spring-loaded terminals
terminals
Single-unit packaging
S00 S00 AC, DC 3RA2911-2AA00 1 1 unit 41B
S0 S0 AC2), DC, AC/DC 3RA2921-2AA00 1 1 unit 41B

3RA2911-2AA00 Multi-unit packaging


S00 S00 AC, DC 3RA2911-2A 1 10 units 41B
S0 S0 AC2), DC, AC/DC 3RA2921-2A 1 10 units 41B
Spacers2)
For height compensation on AC contactors size S0 with
spring-loaded terminals
S0 S0 Single-unit packaging 3RA2911-1CA00 1 1 unit 41B
S0 S0 Multi-unit packaging 3RA2911-1C 1 5 units 41B

3RA2911-1CA00
1)
The link modules for motor starter protector to contactor cannot be used Note:
for 3RV1011, 3RV2.21-4PA1., 3RV2.21-4FA1., 3RV2.31-4K.1.,
3RV2.31-4R.1., 3RV2.32-4K.1., 3RV2.32-4R.1., 3RV27 and 3RV28 Link modules can be used in
motor starter protectors/circuit breakers.
2) A spacer for height compensation on AC contactors size S0 is optionally • Size S00: up to max. 16 A
available. • Size S0: up to max. 32 A
• Size S2: up to max. 65 A

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/61
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Mounting accessories

For For Article No. Price PU PS* PG


3RV2 motor starter 3RW30, 3RW40 soft starters; per PU (UNIT,
protectors/circuit breakers 3RF34 solid-state contactors SET, M)
Size Size
Link modules for motor starter protector to soft starter1) and
motor starter protector to solid-state contactor1)
Connection between motor starter protector and Screw terminals
soft starter/solid-state contactor with screw terminals
Single-unit packaging
S00/S0 S00/S0 3RA2921-1BA00 1 1 unit 41B
S22) S22) 3RA2931-1AA00 1 1 unit 41B
S33) S33) 3RA1941-1AA00 1 1 unit 41B
3RA2921-1BA00 Multi-unit packaging
S00/S0 S00/S0 3RA2921-1B 1 10 units 41B
S22) S22) 3RA2931-1A 1 5 units 41B
S33) S33) 3RA1941-1A 1 5 units 41B
Connection between motor starter protector and Spring-loaded
soft starter with spring-loaded terminals terminals
Single-unit packaging
3RA2931-1AA00 S00 S00 3RA2911-2GA00 1 1 unit 41B
S0 S0 3RA2921-2GA00 1 1 unit 41B

3RA1941-1A
7

3RA2911-2GA00
1)
The link modules from motor starter protector to soft starter and motor Note:
starter protector to solid-state contactor cannot be used for the 3RV1011,
3RV2.21-4PA1., 3RV2.21-4FA1., 3RV2.31-4K.1., 3RV2.31-4R.1., Link modules can be used in
3RV2.32-4K.1., 3RV2.32-4R.1., 3RV27 and 3RV28 motor starter
protectors/circuit breakers. • Size S00: up to max. 16 A
2) • Size S0: up to max. 32 A
To assemble the feeder between a motor starter protector and a soft starter
in size S2, the 3RA2932-1CA00 DIN-rail adapter must be used.
3) • Size S2: up to max. 65 A
It is only permissible to assemble the feeder between the motor starter
protector and the soft starter in size S3 on a mounting plate.

* You can order this quantity or a multiple thereof.


7/62 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Mounting accessories

For For Actuating voltage of Article No. Price PU PS* PG


3RV2 3RT2 contactor per PU (UNIT,
motor starter contactors SET, M)
protectors/
circuit breakers
Size Size
Hybrid link modules for motor starter protector to contactor1)
Mechanical and electrical connection between motor starter
protector with screw terminals and contactor with spring-loaded
terminals
Single-unit packaging
S00 S00 AC, DC 3RA2911-2FA00 1 1 unit 41B
S0 S0 AC2), DC, AC/DC 3RA2921-2FA00 1 1 unit 41B
3RA2911-2FA00 Multi-unit packaging
S00 S00 AC, DC 3RA2911-2F 1 10 units 41B
S0 S0 AC2), DC, AC/DC 3RA2921-2F 1 10 units 41B

3RA2921-2FA00
Spacers2)
For height compensation on AC contactors size S0 with spring-
loaded terminals
S0 S0 Single-unit packaging 3RA2911-1CA00 1 1 unit 41B
S0 S0 Multi-unit packaging 3RA2911-1C 1 5 units 41B

7
3RA2911-1CA00
1)
The hybrid link modules for motor starter protector to contactor cannot be Note:
used for 3RV1011, 3RV2.21-4PA1., 3RV2.21-4FA1., 3RV27 and 3RV28
motor starter protectors/circuit breakers. They are suitable only for Link modules can be used in
constructing direct-on-line starters.
2) • Size S00: up to max. 16 A
A spacer for height compensation on AC contactors size S0 is optionally
available. • Size S0: up to max. 32 A

For motor Version Screw terminals PU PS* PG


starter (UNIT,
protectors/ SET, M)
circuit
breakers
Article No. Price
Type per PU
Connection module (adapter and plug) for motor starter protectors/
circuit breakers with screw terminals
The connection module comprises an adapter
and a motor feeder connector.
Adapter
Ambient temperature tu max. = 60 °C
3RV2.2 Size S0, 3RT1926-4RD01 1 1 unit 41B
rated operational current Ie at
AC-3/AC-3e/400 V: 25 A

3RT1926-4RD01
3RV2.2 Motor feeder connector 3RT1900-4RE01 1 1 unit 41B
Size S0

3RT1900-4RE01

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/63
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Enclosures and front plates

■ Overview
Enclosures There are two knock-out cable entries for cable glands at the top
and two at the bottom; also on the rear corresponding cable
For the stand-alone installation of 3RV20 to 3RV24 motor starter entries are scored. There is a knockout on the top of the
protectors size S00 (In max = 16 A), S0 (In max = 32 A), S2 enclosure for indicator lights that are available as accessories.
(In max = 65 A), and for 3RV1011 motor starter protectors,
molded-plastic and cast aluminum enclosures for surface The narrow enclosure can accommodate a motor starter
mounting and molded-plastic enclosures for flush mounting are protector without accessories, with transverse auxiliary switch
available in various dimensions. and with lateral auxiliary switch. There is no provision for
installing a motor starter protector with a signaling switch.
When installed in a molded-plastic enclosure, the motor starter
protectors have a rated operational voltage Ue of 500 V. With size S00 to S2 3RV2 circuit breakers, the molded-plastic
enclosures are equipped with a rotary operating mechanism.
The enclosures for surface mounting have the degree of
protection IP55; the enclosures for flush mounting also comply The enclosures can be supplied with either a black rotary
with the degree of protection IP55 at the front. The cast operating mechanism or with an EMERGENCY OFF rotary
aluminum enclosures for surface mounting achieve degree of operating mechanism with a red/yellow knob.
protection IP65.
In the OFF position, all rotary operating mechanisms can be
locked with up to three padlocks. These enclosures are not
suitable for 3RV1011 motor starter protectors.
Front plates
Motor starter protectors are frequently required to be actuated in
any enclosure. Front plates equipped with a rotary operating
mechanism for 3RV20 to 3RV24 motor starter protectors sizes
S00 to S3 are available for this purpose.
A holder for the motor starter protectors sizes S00 and S0, into
which the motor starter protectors can be snapped, is available
7

for the front plates. It is not possible to use a signaling switch or


4-pole auxiliary switch. The front plates are not suitable for
3RV1011 motor starter protectors.

NSB0_02081a

Enclosures for surface mounting

NSB0_02083a

Front plate (including holder) for sizes S00 and S0


NSB0_02082a

Enclosures for flush mounting (only for sizes S00 and S0)

7/64 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Enclosures and front plates

■ Selection and ordering data


Version Degree Inte- Width For 3RV20 Article No. Price PU PS* PG
of pro- grated to 3RV24 per PU (UNIT,
tection termi- motor SET, M)
nals starter
protectors
mm Size
Molded-plastic enclosures for surface mounting1)
With rotary IP55 N and 54 S003), S0 3RV1923-1CA00 1 1 unit 41E
operating PE (for motor starter protector
mechanism, + lateral auxiliary switch)
lockable in 72 S003), S0 3RV1923-1DA00 1 1 unit 41E
0 position (for motor starter protector
+ lateral auxiliary switch2)
3RV1933-1DA00 + auxiliary release)
82 S2 3RV1933-1DA00 1 1 unit 41E
(for motor starter protector
2)
+ lateral auxiliary switch
+ auxiliary release)
With IP55 N and 54 S003), S0 3RV1923-1FA00 1 1 unit 41E
EMERGENCY PE (for motor starter protector
OFF rotary + lateral auxiliary switch)
operating 72 S003), S0 3RV1923-1GA00 1 1 unit 41E
mechanism, (for motor starter protector
lockable in + lateral auxiliary switch2)
3RV1923-1FA00, 0 position + auxiliary release)
3RV1933-1GA00
82 S2 3RV1933-1GA00 1 1 unit 41E
(for motor starter protector
2)
+ lateral auxiliary switch

7
+ auxiliary release)
Cast aluminum enclosures for surface mounting1)
With rotary IP65 PE4) 72 S003), S0 3RV1923-1DA01 1 1 unit 41E
operating (for motor starter protector
mechanism, + lateral auxiliary switch2)
lockable in + auxiliary release)
0 position
With IP65 PE4) 72 S003), S0 3RV1923-1GA01 1 1 unit 41E
3RV1923-1DA01 EMERGENCY (for motor starter protector
OFF rotary + lateral auxiliary switch2)
operating + auxiliary release)
mechanism,
lockable in
0 position
Molded-plastic enclosures for flush mounting5)
With rotary IP55 N and 72 S003), S0 3RV1923-2DA00 1 1 unit 41E
operating (front PE (for motor starter protector
mechanism, side) + lateral auxiliary switch2)
lockable in + auxiliary release)
0 position

3RV1923-2DA00
With IP55 N and 72 S003), S0 3RV1923-2GA00 1 1 unit 41E
EMERGENCY (front PE (for motor starter protector
OFF rotary side) + lateral auxiliary switch2)
operating + auxiliary release)
mechanism,
lockable in
0 position
With actuator IP55 N and 72 S006) 3RV1913-2DA00 1 1 unit 41E
diaphragm (front PE (for motor starter protector
side) + lateral auxiliary switch2)
+ auxiliary release)

3RV1913-2DA00
Molded-plastic enclosures for surface mounting
With actuator IP55 N and 85 S006) 3RV1913-1CA00 1 1 unit 41E
diaphragm PE 105 S006) 3RV1913-1DA00 1 1 unit 41E

3RV1913-1CA00
1) The rear cable bushings cannot be used on 3RV2.11-...2. and 5) Not suitable for 3RV2.11-...2. and 3RV2.21-...2. devices with spring-loaded
3RV2.21-...2. devices with spring-loaded terminals. terminals.
2) 6)
Only valid for lateral auxiliary switches with two auxiliary contacts. Only for 3RV1011 motor starter protectors.
3)
Not for 3RV1011 motor starter protectors.
4) If required, an additional N terminal can be mounted (e.g. 8WA1011-1BG11).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/65
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
Accessories > Enclosures and front plates

Version Degree of For 3RV20 Article No. Price PU PS* PG


protection to 3RV24 per PU (UNIT,
motor SET, M)
starter
protectors
Size
Front plates1)
Molded-plastic front plates with rotary IP55 S002) 3RV1923-4B 1 1 unit 41E
operating mechanism, (front side) up to S3
lockable in 0 position
For actuation of 3RV2 motor starter
protectors in any enclosure
Molded-plastic front plates with IP55 S002) 3RV1923-4E 1 1 unit 41E
EMERGENCY OFF rotary operating (front side) up to S3
mechanism, red/yellow,
3RV1923-4B + lockable in 0 position
3RV1923-4G EMERGENCY OFF actuation of
3RV2 motor starter protectors in any
enclosure
Holders for front plates -- S002), S0 3RV1923-4G 1 1 unit 41E
Holder is mounted on front plate, motor
starter protector with and without
accessories is snapped in.
1)
It is not possible to use a signaling switch or 4-pole auxiliary switch with
front plates.
2)
Not for 3RV1011 motor starter protectors.

Version Rated control For 3RV20 Article No. Price PU PS* PG


supply voltage Us to 3RV24 per PU (UNIT,
7

motor SET, M)
starter
protectors
V Size
Indicator lights
Indicator lights 110 ... 120 S00 to S3 3RV1903-5B 1 1 unit 41E
For all enclosures and front plates 220 ... 240 3RV1903-5C 1 1 unit 41E
• With LED lamp for versions 380 ... 415 3RV1903-5E 1 1 unit 41E
110 ... 120 V, 480 ... 500 3RV1903-5G 1 1 unit 41E
with glow lamp for versions
220 ... 500 V
3RV1903-5B • With colored lenses red, green,
yellow-orange and clear

* You can order this quantity or a multiple thereof.


7/66 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
3RV29 infeed system

■ Overview
The 3RV29 infeed system is a convenient means of energy degree of flexibility for configuring the control cabinet: Infeed on
supply and distribution for a group of several motor starter left-hand or right-hand side as well as infeed on one side and
protectors or complete load feeders with screw or spring-loaded outfeed on the other side to supply further loads are all possible.
terminals in sizes S00 and S0. Motor starter protectors or load A terminal block with spring-loaded terminals in combination
feeders with a rated current of maximum 32 A each can be used. with a DIN rail enables the integration of not only SIRIUS motor
3RV21 motor starter protectors cannot be used in this system. starter protectors but also 1-phase, 2-phase and 3-phase
components such as 5SY miniature circuit breakers or
The system is based on a basic module complete with a lateral SIRIUS relay components.
incoming unit (3-phase busbar with infeed). This infeed with
spring-loaded terminals is mounted on the right or left, The 3RV29 infeed system is approved in accordance with IEC to
depending on the version, and can be supplied with a maximum 500 V. It is also UL-approved and authorized for "Self-Protected
conductor cross-section of 25 mm2 (with end sleeve). A basic Combination Motor Controllers" starters (Type E), for starters
module has two sockets onto each of which a motor starter (Type F) (starters (Type E) + contactors) and for circuit breakers
protector can be snapped. according to UL 489 (3RV27/3RV28).
Expansion modules (3-phase busbars for system expansion) Assembly kits for constructing the infeed system with
are available for extending the system. The individual modules spring-loaded terminals
are connected through an expansion plug.
The following versions can be ordered:
The electrical connection between the 3-phase busbars and • Basic set for two feeders
the motor starter protectors is implemented through plug-in
connectors. The complete system can be mounted on • Expansion sets for two or three feeders
a TH 35 DIN rail to IEC 60715, and can be expanded as required The assembly kits contain 3-phase busbars, plug-in connectors
up to a maximum current carrying capacity of 63 A. and contactor bases (see page 7/72).
The system is mounted extremely quickly and easily thanks to Note:
the simple plug-in terminals. Thanks to the lateral infeed, the
system also saves space in the control cabinet. Each set contains plug-in connectors for sizes S00 and S0.

7
The additional height required for the infeed unit is only 30 mm. Example: The basic set contains four plug-in connectors
The alternative infeed possibilities on each side offer a high (two each for S00 and S0).

6 1 3-phase busbar with infeed


6
5 2 3-phase busbar for system expansion
3b 3a 3a Expansion plug
3b Extra-wide expansion plug
4 End cover
5 Terminal block for device infeed
6 Plug-in connector
7 Contactor base
1
8 Terminal block

2
4

7
IC01_00634a

SIRIUS 3RV29 infeed system

Siemens IC 10 · 2023 7/67


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
3RV29 infeed system
$ 3-phase busbars with infeed + Contactor base
A 3-phase busbar with infeed unit is required for connecting the Load feeders can be assembled in the system using the S00
incoming supply. These modules comprise one infeed module and S0 contactor base. The contactor bases are suitable for
and two sockets which each accept one motor starter protector. contactors of sizes S00 and S0 with screw and spring-loaded
A choice of two versions with infeed on the left or right is terminals and are simply snapped onto the 3-phase busbars.
available. The infeed is connected to spring-loaded terminals. Direct-on-line starters and reversing starters are possible. One
They permit an infeed with conductor cross-sections of up to contactor base is required for direct-on-line starters and two are
25 mm2 with end sleeve. An end cover is supplied with required for reversing starters.
each module.
To assemble load feeders for reversing starters, the contactor
% 3-phase busbars for system expansion bases can be arranged alongside each other (90 mm overall
width). In this case the mechanical interlocking of the contactors
The 3-phase busbars for system expansion support expansion is possible. The S0 contactor bases are also suitable for soft
of the system. There is a choice of modules with two or three starters size S00 and S0 with screw terminal.
sockets. The system can be expanded as required up to
a maximum current carrying capacity of 63 A. An expansion The infeed system is designed for mounting on a TH 35 DIN rail
plug is supplied with each module. with 7.5 mm overall depth. This DIN rail gives the contactor base
a stable mounting surface to sit on. If DIN rails with a depth of
&a Expansion plug 15 mm are used, the spacer connected to the bottom of the
contactor base must be knocked out and plugged into the
The expansion plug is used for electrical connection of adjacent DIN rail mating piece, which is also located on the underside.
3-phase busbars. The current carrying capacity of this plug Then the contactor base also has a stable mounting surface.
equals 63 A. One expansion plug is supplied with each 3-phase When DIN rails with a depth of 7.5 mm are used, the spacer has
busbar for system expansion. Additional expansion plugs are no function and can be removed.
therefore only required as spare parts.
The link modules are used for direct on-line starters, in which
&b Extra-wide expansion plug case the use of a contactor base is not absolutely necessary.
The wide expansion plug makes the electrical connection Motor starter protector and contactor assemblies can then be
between two 3-phase busbars, thus performing the same directly snapped onto the sockets of the 3-phase busbars.
For feeders of sizes S00 and S0, the corresponding
7

function as the 3RV2917-5BA00 expansion plug; the electrical


characteristics (e.g. a current carrying capacity of 63 A) 3RA1921-1...., 3RA2911-2...., 3RA2921-1.... or 3RA2921-2....
are identical. link modules should generally be used.

The 3RV2917-5E expansion plug is 10 mm wider than the , Terminal block


3RV2917-5BA00 expansion plug, hence in the plugged state The 3RV2917-5D terminal block enables the integration of not
there is a distance of 10 mm between the connected 3-phase only SIRIUS motor starter protectors but also 1-phase, 2-phase
busbars. This distance can be used to lay the auxiliary current and 3-phase components. The three phases can be fed out of
and control current wiring ("wiring duct"). The motor starter the system using the terminal block; which means that single-
protector and contactor can be wired from underneath, phase loads can also be integrated in the system. The terminal
which means that the complete cable duct above the system block is plugged into the slot of the expansion plug and thus
can be omitted. enables outfeeding from the middle or end of the infeed system.
The terminal block can be rotated through 180° and be locked
( End cover to the support modules of the infeed system. In addition, the
The end cover is used to cover the 3-phase busbar at the open 45 mm wide TH 35 3RV1917-7B DIN rail option for screwing
end of the system. This cover is therefore only required once for onto the support plate facilitates plugging the 1-phase, 2-phase
each system. An end cover is supplied with each 3-phase and 3-phase components onto the infeed system.
busbar system with infeed. Further end covers are therefore only
required as spare parts.
) Terminal block for device infeed
A new addition to the system is a plug for outfeeding to a device
slot within a module. This offers the option not only of connecting
Video:
three-phase loads to the system, but also of integrating 1-phase SIRIUS News SIRIUS 3RV29 infeed system - Assembly without tools
loads into the infeed system.

* Plug-in connector
The plug-in connector is used for the electrical connection
between the 3-phase busbar and the 3RV2 or 3RV1011 motor
starter protector. These plug-in connectors are available for
screw or spring-loaded terminals.

7/68 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
3RV29 infeed system

■ Technical specifications
More information
Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60279172

General data
Type 3RV29.7
Size S00, S0
Standards
• IEC 60947-2 Yes
• IEC 60947-4-1 Yes
• UL 508/UL 60947-4-1 Yes
Rated current In A 63
Permissible rated current at inside temperature of control cabinet
Motor starter Size Rated current Inside
protectors temperature of
control cabinet
• 3RV2.11/3RV1011 S00 ... 14 A 60 °C % 100
> 14 ... 16 A 40 °C % 100
60 °C % 87
• 3RV2.21 S0 ... 16 A 60 °C % 100
> 16 ... 25 A 40 °C % 100
60 °C % 87
> 25 ... 32 A 40 °C % 87
Permissible ambient temperature

7
• Storage/transport °C -50 ... +80
• Operation °C -20 ... +60
Rated operational voltage Ue
• According to IEC 10% overvoltage V AC 500
5% overvoltage V AC 525
• According to UL/CSA V AC 600
Rated frequency Hz 50/60
Rated impulse withstand voltage Uimp kV 6
Short-circuit strength corresponds to the mounted motor starter protector or load feeder.
The assembly instructions must be followed, see Operating Instructions
Degree of protection IP on the front according to IEC 60529 IP20 with cover and 25 mm2 conductor cross-section at the infeed terminal
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching from the front with cover and 25 mm2
conductor cross-section at the infeed terminal

Conductor cross-sections
Type 3-phase busbar Terminal block Terminal block for
with infeed device infeed
3RV2917-1A,
3RV2917-1E 3RV2917-5D 3RV2917-5FA00
Conductor cross-sections (min./max.)
• Solid or stranded mm2 4 ... 25 1.5 ... 6 1 ... 10
• Finely stranded with end sleeve mm2 4 ... 25 1.5 ... 4 1 ... 6
• Finely stranded without end sleeve mm2 6 … 25 1.5 ... 6 --
• AWG cables AWG 10 ... 3 15 ... 10 18 ... 8

Siemens IC 10 · 2023 7/69


© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
3RV29 infeed system

■ Selection and ordering data


Type Version For 3RV20, Article No. Price PU PS* PG
3RV23, per PU (UNIT,
3RV24, SET, M)
3RV27,
3RV28,
3RV1011
motor
starter
protectors
Size
3-phase busbars with infeed
3-phase busbars For two motor starter
with infeed protectors with screw or
Incl. 3RV2917-6A spring-loaded terminals
end cover • With infeed on the left S00, S0 3RV2917-1A 1 1 unit 41E
• With infeed on the right S00, S0 3RV2917-1E 1 1 unit 41E

3RV2917-1A
3-phase busbars for system expansion
3-phase busbars For motor starter
Incl. 3RV2917-5BA00 protectors with screw or
expansion plug spring-loaded terminals
• For 2 motor starter S00, S0 3RV2917-4A 1 1 unit 41E
protectors
7

• For 3 motor starter S00, S0 3RV2917-4B 1 1 unit 41E


protectors

3RV2917-4A
Plug-in connectors
Plug-in connectors • For spring-loaded Spring-loaded
To make contact with terminals terminals
the 3RV2 motor starter
protectors - Single-unit packaging S001) 3RV2917-5AA00 1 1 unit 41E
S02) 3RV2927-5AA00 1 1 unit 41E
- Multi-unit packaging S001) 3RV2917-5A 1 10 units 41E
S02) 3RV2927-5A 1 10 units 41E
3RV2917-5AA00
• For screw terminals Screw terminals

- Single-unit packaging S001)3) 3RV2917-5CA00 1 1 unit 41E


S02)4) 3RV1927-5AA00 1 1 unit 41E
- Multi-unit packaging S001)3) 3RV2917-5C 1 10 units 41E
2)4)
S0 3RV1927-5A 1 10 units 41E

3RV2917-5CA00
Plug-in connectors • For screw terminals
To make contact with
the 3RV1011 motor - Single-unit packaging S00 3RV1917-5CA00 1 1 unit 41E
starter protectors
- Multi-unit packaging S00 3RV1917-5C 1 10 units 41E
1) 4)
I > 14 A, please note derating. The plug-in connector can be used for the 3RV2711, 3RV2811 (size S00)
2) I > 16 A, please note derating. and 3RV2721, 3RV2821 (size S0) circuit breakers.
3)
The plug-in connector cannot be used for the 3RV2711 and 3RV2811
circuit breakers with size S00.

Type Version For Article No. Price PU PS* PG


contactors per PU (UNIT,
SET, M)
Size
Contactor bases
Contactor bases Single-unit packaging S001) 3RV2917-7AA00 1 1 unit 41E
For mounting direct-on- S001), S0 3RV2927-7AA00 1 1 unit 41E
line or reversing
starters

3RV2927-7AA00
1)
Not for 3RV1011 motor starter protectors.

* You can order this quantity or a multiple thereof.


7/70 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
3RV29 infeed system

Type Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Terminal blocks
Terminal blocks Single-unit packaging 3RV2917-5D 1 1 unit 41E
For integration of 1-phase,
2-phase and 3-phase
components

3RV2917-5D
TH 35 DIN rails, width 45 mm
TH 35 DIN rails Single-unit packaging 3RV1917-7B 1 1 unit 41E
According to IEC 60715,
width 45 mm
For mounting on 3-phase
busbars

3RV1917-7B
Extra-wide expansion plugs
Extra-wide expansion plugs Single-unit packaging 3RV2917-5E 1 1 unit 41E
As accessory

7
3RV2917-5E
Expansion plugs
Expansion plugs1) Single-unit packaging 3RV2917-5BA00 1 1 unit 41E
As spare part

3RV2917-5BA00
End covers
End covers2) Multi-unit packaging 3RV2917-6A 100 10 units 41E
As spare part

3RV2917-6A
Terminal blocks for device infeed
Terminal blocks for Single-unit packaging 3RV2917-5FA00 1 1 unit 41E
device infeed

3RV2917-5FA00
1)
The expansion plug is included in the scope of supply of the 3RV2917-4.
3-phase busbars for system expansion.
2) The end cover is included in the scope of supply of the 3RV2917-1.
3-phase busbars with infeed system.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/71
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV2 motor starter protectors/circuit breakers
3RV29 infeed system

Version For motor Spring-loaded PU PS* PG


starter terminals (UNIT,
protectors/ SET, M)
circuit
breakers
with
spring-
loaded
terminals
Article No. Price
Size per PU
Assembly kits for constructing the infeed system
with spring-loaded terminals1)
Basic set for two feeders 3RV2907-1AB00 1 1 unit 41E
contains:
• 1 x 3-phase busbars 3RV2917-1A S00, S0
(incl. end cover 3RV2917-6A),
with infeed left,
for two motor starter protectors with spring-loaded
terminals
• 2 x plug-in connectors for spring-loaded terminals S00
3RV2917-5AA00
• 2 x plug-in connectors for spring-loaded terminals S0
3RV2927-5AA00
• 2 x 3RV2927-7AA00 contactor bases S00, S0
Expansion set for two feeders 3RV2907-4AB00 1 1 unit 41E
contains:
• 1 x 3-phase busbars 3RV2917-4A S00, S0
(incl. expansion plug 3RV2917-5BA00),
for two motor starter protectors with spring-loaded
7

terminals
• 2 x plug-in connectors for spring-loaded terminals S00
3RV2917-5AA00
• 2 x plug-in connectors for spring-loaded terminals S0
3RV2927-5AA00
• 2 x 3RV2927-7AA00 contactor bases S00, S0
Expansion set for three feeders 3RV2907-4BB00 1 1 unit 41E
contains:
• 1 x 3-phase busbars 3RV2917-4B S00, S0
(incl. expansion plug 3RV2917-5BA00),
for three motor starter protectors with spring-loaded
terminals
• 3 x plug-in connectors for spring-loaded terminals S00
3RV2917-5AA00
• 3 x plug-in connectors for spring-loaded terminals S0
3RV2927-5AA00
• 3 x 3RV2927-7AA00 contactor bases S00, S0
1) Not for 3RV1011 motor starter protectors.

* You can order this quantity or a multiple thereof.


7/72 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV1 motor starter protectors/circuit breakers
AC-3e E3 ready IE4 ready IE3/IE4 ready For fuse monitoring

■ Technical specifications
See pages 7/9, 7/11, 7/14, 7/19, 7/20 and 7/23

■ Selection and ordering data


Without auxiliary switches
Rated current Thermal Instantaneous Short-circuit Screw terminals PU PS* PG
overload release electronic breaking (UNIT,
release capacity at SET, M)
400 V AC
In Icu Article No. Price
per PU

A A A kA
Size S00
0.2 0.2 1.2 100 3RV1611-0BD10 1 1 unit 41E

3RV1611-0BD10

7
Note:
The auxiliary switch required for signaling must be ordered
separately.

■ Accessories
Version Contacts Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price
per PU

Mountable auxiliary switches (essential accessories)


Transverse auxiliary switches 1 NO + 1 NC 3RV2901-1E 1 1 unit 41E
With screw terminals, mountable on the front

3RV2901-1E
Lateral auxiliary switches 1 NO + 1 NC 3RV2901-1A 1 1 unit 41E
With screw terminals, mountable on the left

3RV2901-1A

Additional auxiliary switches and other accessories, see from page 7/47 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/73
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV1 motor starter protectors/circuit breakers
For distance protection

■ Technical specifications
See page 7/24

■ Selection and ordering data


Voltage transformer motor starter protectors with transverse auxiliary switches (1 CO)
Rated Thermal Instantaneous Auxiliary Short-circuit Screw terminals PU PS* PG
current overload electronic switch breaking (UNIT,
release release integrated in capacity at SET, M)
the motor 400 V AC
starter
protector,
transverse
In Icu Article No. Price
per PU
A A A kA
Size S00
1.4 1.4 6 1 CO 50 3RV1611-1AG14 1 1 unit 41E
2.5 2.5 10.5 1 CO 50 3RV1611-1CG14 1 1 unit 41E
3 3 20 1 CO 50 3RV1611-1DG14 1 1 unit 41E

3RV1611-1.G14
7

■ Accessories
Version Contacts Screw terminals PU PS* PG
(UNIT,
SET, M)
Article No. Price
per PU

Mountable auxiliary switches for other signaling purposes


Lateral auxiliary switches 1 NO + 1 NC 3RV2901-1A 1 1 unit 41E
With screw terminals, mountable on the left

3RV2901-1A
Additional auxiliary switches and other accessories, see from page 7/47 onwards.

* You can order this quantity or a multiple thereof.


7/74 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Motor starter protectors/circuit breakers
SIRIUS 3RV1 motor starter protectors/circuit breakers
AC-3e E3 ready IE4 ready IE3/IE4 ready For motor protection

■ Selection and ordering data


CLASS 10, without auxiliary switches
Rated Suitable for Setting range Instantaneous Short-circuit Screw terminals PU PS* PG
current three-phase for thermal electronic breaking (UNIT,
motors1) overload release capacity at SET, M)
with P release 400 V AC
In Icu Article No. Price
per PU

A kW A A kA
Size S00
0.16 0.04 0.11 ... 0.16 2.1 100 3RV1011-0AA10 1 1 unit 41E
0.2 0.06 0.14 ... 0.2 2.6 100 3RV1011-0BA10 1 1 unit 41E
0.25 0.06 0.18 ... 0.25 3.3 100 3RV1011-0CA10 1 1 unit 41E
0.32 0.09 0.22 ... 0.32 4.2 100 3RV1011-0DA10 1 1 unit 41E
0.4 0.09 0.28 ... 0.4 5.2 100 3RV1011-0EA10 1 1 unit 41E
0.5 0.12 0.35 ... 0.5 6.5 100 3RV1011-0FA10 1 1 unit 41E
0.63 0.18 0.45 ... 0.63 8.2 100 3RV1011-0GA10 1 1 unit 41E
0.8 0.18 0.55 ... 0.8 10 100 3RV1011-0HA10 1 1 unit 41E
1 0.25 0.7 ... 1 13 100 3RV1011-0JA10 1 1 unit 41E
1.25 0.37 0.9 ... 1.25 16 100 3RV1011-0KA10 1 1 unit 41E
3RV1011-..A10 1.6 0.55 1.1 ... 1.6 21 100 3RV1011-1AA10 1 1 unit 41E
2 0.75 1.4 ... 2 26 100 3RV1011-1BA10 1 1 unit 41E
2.5 0.75 1.8 ... 2.5 33 100 3RV1011-1CA10 1 1 unit 41E
3.2 1.1 2.2 ... 3.2 42 100 3RV1011-1DA10 1 1 unit 41E
4 1.5 2.8 ... 4 52 100 3RV1011-1EA10 1 1 unit 41E
5 1.5 3.5 ... 5 65 100 3RV1011-1FA10 1 1 unit 41E

7
6.3 2.2 4.5 ... 6.3 82 100 3RV1011-1GA10 1 1 unit 41E
8 3 5.5 ... 8 104 50 3RV1011-1HA10 1 1 unit 41E
10 4 7 ... 10 130 50 3RV1011-1JA10 1 1 unit 41E
12 5.5 9 ... 12 156 50 3RV1011-1KA10 1 1 unit 41E
1) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual The accessories of 3RV2 motor starter protectors/circuit breakers
starting and rated data of the motor to be protected must be considered can be used with exceptions, see page 7/47 onwards.
when selecting the units.

CLASS 10, with transverse auxiliary switch (1 NO + 1 NC)


Rated Suitable for Setting range Instantaneous Short-circuit Screw terminals PU PS* PG
current three-phase for thermal electronic breaking (UNIT,
motors1) overload release capacity at SET, M)
with P release 400 V AC
In Icu Article No. Price
per PU

A kW A A kA
Size S00
0.16 0.04 0.11 ... 0.16 2.1 100 3RV1011-0AA15 1 1 unit 41E
0.2 0.06 0.14 ... 0.2 2.6 100 3RV1011-0BA15 1 1 unit 41E
0.25 0.06 0.18 ... 0.25 3.3 100 3RV1011-0CA15 1 1 unit 41E
0.32 0.09 0.22 ... 0.32 4.2 100 3RV1011-0DA15 1 1 unit 41E
0.4 0.09 0.28 ... 0.4 5.2 100 3RV1011-0EA15 1 1 unit 41E
0.5 0.12 0.35 ... 0.5 6.5 100 3RV1011-0FA15 1 1 unit 41E
0.63 0.18 0.45 ... 0.63 8.2 100 3RV1011-0GA15 1 1 unit 41E
0.8 0.18 0.55 ... 0.8 10 100 3RV1011-0HA15 1 1 unit 41E
1 0.25 0.7 ... 1 13 100 3RV1011-0JA15 1 1 unit 41E
1.25 0.37 0.9 ... 1.25 16 100 3RV1011-0KA15 1 1 unit 41E
3RV1011-..A15 1.6 0.55 1.1 ... 1.6 21 100 3RV1011-1AA15 1 1 unit 41E
with integrated 2 0.75 1.4 ... 2 26 100 3RV1011-1BA15 1 1 unit 41E
transverse 2.5 0.75 1.8 ... 2.5 33 100 3RV1011-1CA15 1 1 unit 41E
auxiliary switch 3.2 1.1 2.2 ... 3.2 42 100 3RV1011-1DA15 1 1 unit 41E
4 1.5 2.8 ... 4 52 100 3RV1011-1EA15 1 1 unit 41E
5 1.5 3.5 ... 5 65 100 3RV1011-1FA15 1 1 unit 41E
6.3 2.2 4.5 ... 6.3 82 100 3RV1011-1GA15 1 1 unit 41E
8 3 5.5 ... 8 104 50 3RV1011-1HA15 1 1 unit 41E
10 4 7 ... 10 130 50 3RV1011-1JA15 1 1 unit 41E
12 5.5 9 ... 12 156 50 3RV1011-1KA15 1 1 unit 41E
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual The accessories of 3RV2 motor starter protectors/circuit breakers
starting and rated data of the motor to be protected must be considered can be used with exceptions, see page 7/47 onwards.
when selecting the units.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/75
© Siemens 2023

Protection equipment
Overload relays
General data

■ Overview
More information
Homepage, see www.siemens.com/sirius-control TIA Selection Tool Cloud (TST Cloud), see
Industry Mall, see www.siemens.com/tstcloud/?node=ElectronicOverloadRelay
• www.siemens.com/product?3RU2 Configuration Manual for load feeders, see
https://support.industry.siemens.com/cs/ww/en/view/39714188
• www.siemens.com/product?3RB3
Conversion tool, see www.siemens.com/conversion-tool
• www.siemens.com/product?3RB2

Features 3RU21 3RB30/3RB31 3RB20/3RB21 3RB22/3RB23 3RB24 Benefits


General data
Sizes S00 ... S3 S00 ... S3 S6 ... S12 S00 ... S12 S00 ... S12 • Are coordinated with the dimensions,
connections and technical characteristics
of the other devices in the SIRIUS modular
system (contactors, etc.)
• Permit the mounting of slim and compact
load feeders in widths of 45 mm (S00, S0),
55 mm (S2), 70 mm (S3), 120 mm (S6) and
7

145 mm (S10/S12); this does not include the


current measuring modules for the 3RB22 to
3RB24 evaluation modules sizes S00 to S3
• Simplify configuration
Seamless current 0.11 ... 100 A 0.1 ... 115 A 50 ... 630 A 0.3 ... 630 A 0.3 ... 630 A • Allows easy and consistent configuration
range (up to 820 A)1) (up to 820 A)1) with one series of overload relays (for small
to large loads)
Protection functions
Tripping ✓ ✓ ✓ ✓ ✓ • Provides optimum inverse-time delayed
due to protection of loads against excessive
overload temperature rises due to overload
Tripping due to ✓ ✓ ✓ ✓ ✓ • Provides optimum inverse-time delayed
phase asymmetry protection of loads against excessive
temperature rises due to phase asymmetry
Tripping ✓ ✓ ✓ ✓ ✓ • Minimizes heating of three-phase motors
due to phase failure during phase failure
Protection of ✓ -- -- ✓ ✓ • Enables the protection of single-phase
single-phase loads loads
Tripping in the event --2) --2) --2) ✓ ✓ • Provides optimum temperature-dependent
of overheating protection of loads against excessive
temperature rises, e.g. for stator-critical
by motors or in the event of insufficient coolant
flow, contamination of the motor surface or
Integrated long starting or braking operations
thermistor motor • Eliminates the need for additional special
protection function equipment
• Saves space in the control cabinet
• Reduces wiring outlay and costs
Tripping in the event -- ✓ ✓ ✓ ✓ • Provides optimum protection of loads
of a ground fault (only 3RB31) (only 3RB21) against incomplete ground faults due to
moisture, condensed water, damage to the
by insulation material, etc.
• Eliminates the need for additional special
Internal ground-fault equipment
detection
(activatable) • Saves space in the control cabinet
• Reduces wiring outlay and costs
✓ Available 1) Motor currents up to 820 A can be recorded and evaluated, e.g. by
-- Not available a 3RB2906-2BG1 current measuring module (0.3 to 3 A), in combination
with a 3UF1868-3GA00 (820 A/1 A) series transformer.
For 3UF18 transformers, see page 10/21.
2)
The SIRIUS 3RN thermistor motor protection devices can be used to
provide additional temperature-dependent protection.

7/76 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
General data

Features 3RU21 3RB30/3RB31 3RB20/3RB21 3RB22/3RB23 3RB24 Benefits


Features
RESET function ✓ ✓ ✓ ✓ ✓ • Allows manual or automatic resetting of the
device
Remote RESET ✓ ✓ ✓ ✓ ✓ • Allows the remote resetting of the device
function (by means of (only with 3RB31 (only with 3RB21 (electrically via (electrically with
separate and external and external external button) button or via
module) auxiliary voltage auxiliary voltage IO-Link)
24 V DC) 24 V DC)
TEST function for ✓ ✓ ✓ ✓ ✓ • Allows easy checking of the function and
auxiliary contacts wiring
TEST function for -- ✓ ✓ ✓ ✓ • Allows checking of the electronics
electronics
Status display ✓ ✓ ✓ ✓ ✓ • Displays the current operating state
Large current ✓ ✓ ✓ ✓ ✓ • Makes it easier to set the relay exactly to the
adjustment button correct current value
Integrated auxiliary ✓ ✓ ✓ ✓ -- • Allow the load to be switched off if necessary
contacts (2 x) • Can be used to output signals
(1 NO + 1 NC)

7
Integrated auxiliary -- -- -- -- ✓ • Enable the controlling of contactors directly
contacts from the higher-level control system through
(1 CO and 1 NO in IO-Link
series)
IO-Link connection -- -- -- -- ✓ • Reduction of wiring in the control cabinet
• Enables communication
Connection of -- -- -- -- ✓ • Enables local operation
optional handheld
device
Communication capability through IO-Link
Full starter -- -- -- -- ✓ • Enables in combination with the SIRIUS 3RT
functionality contactors the assembly of communication-
through IO-Link capable motor starters (direct-on-line,
reversing and star-delta (wye-delta) starting)
Readout of -- -- -- -- ✓ • Enables the readout of diagnostics
diagnostics information such as overload, open circuit,
functions ground fault, etc.
Readout of current -- -- -- -- ✓ • Enables the readout of current values and
values their direct processing in the higher-level
control system
Readout of all set -- -- -- -- ✓ • Enables the readout of all set parameters,
parameters e.g. for plant documentation
✓ Available
-- Not available

Siemens IC 10 · 2023 7/77


© Siemens 2023

Protection equipment
Overload relays
General data

Features 3RU21 3RB30/3RB31 3RB20/3RB21 3RB22/3RB23 3RB24 Benefits


Design of load feeders
Short-circuit ✓ ✓ ✓ ✓ ✓ • Provides optimum protection of the loads
strength up to and operating personnel in the event of
100 kA short circuits due to insulation faults or faulty
at 690 V switching operations
(in conjunction with
the corresponding
fuses or the
corresponding motor
starter protector)
Electrical and ✓ ✓ ✓ ✓1) ✓1) • Simplifies configuration
mechanical • Reduces wiring outlay and costs
matching to
3RT contactors • Enables stand-alone installation as well as
space-saving direct mounting
Straight-through -- ✓ ✓ ✓ ✓ • Reduce the contact resistance (only one
transformers for (S2, S3) (S6) (S00 ... S6) (S00 ... S6) point of contact)
main circuit2) • Save wiring costs (easy, no need for tools,
(in this case the and fast)
cables are routed
• Save material costs
7

through the feed-


through openings of • Reduce installation costs
the overload relay
and connected
directly to the box
terminals of the
contactor)
Spring-loaded ✓ ✓ -- -- -- • Enable fast connections
terminals for main (S00, S0) (S00, S0) • Permit vibration-resistant connections
circuit2)
• Enable maintenance-free connections
Spring-loaded ✓ ✓ ✓ ✓ ✓ • Enable fast connections
terminals for • Permit vibration-resistant connections
auxiliary circuits2)
• Enable maintenance-free connections
Full starter -- -- -- -- ✓ • Enables in combination with the SIRIUS 3RT
functionality contactors the assembly of communication-
through IO-Link capable motor starters (direct-on-line,
reversing and star-delta (wye-delta) starting)
Starter function -- -- -- -- ✓ • Integration of feeders via IO-Link in the
control system up to 630 A or 820 A
✓ Available 1) Exception: up to size S3, only stand-alone installation is possible.
2)
-- Not available Available as an alternative to screw terminals.

7/78 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
General data

Features 3RU21 3RB30/3RB31 3RB20/3RB21 3RB22/3RB23 3RB24 Benefits


Other features
Temperature ✓ ✓ ✓ ✓ ✓ • Allows the use of the relays at high
compensation temperatures without derating
• Prevents premature tripping
• Allows compact installation of the control
cabinet without distance between the
devices/load feeders
• Simplifies configuration
• Enables space to be saved in the control
cabinet
Very high long-term ✓ ✓ ✓ ✓ ✓ • Provides safe protection for the loads even
stability after years of use in harsh operating
conditions
Wide setting ranges -- ✓ ✓ ✓ ✓ • Minimize the configuring outlay and costs
(1:4) (1:4) (1:10) (1:10) • Minimize storage overhead, storage costs,
and tied-up capital
Fixed trip class CLASS 10, 3RB30: 3RB20: -- -- • Optimum motor protection for standard
CLASS 10A CLASS 10E or CLASS 10E or starts

7
CLASS 20E CLASS 20E
CLASS 5E, 10E, 20E, -- ✓ ✓ ✓ ✓ • Enable solutions for very fast starting motors
30E trip classes (only 3RB31) (only 3RB21) requiring special protection (e.g. Ex motors)
adjustable on the • Enable heavy starting solutions
device
• Reduce the number of variants
• Minimize the configuring outlay and costs
• Minimize storage overhead, storage costs,
and tied-up capital
Low power loss -- ✓ ✓ ✓ ✓ • Reduces power consumption and energy
costs (up to 98% less power is used than for
thermal overload relays)
• Minimizes temperature rises of the
contactor and control cabinet – in some
cases this may eliminate the need for
control cabinet cooling
• Direct mounting to contactor saves space,
even for high motor currents (i.e. no heat
decoupling is required)
Internal power --1) ✓ ✓ -- -- • Eliminates the need for configuration and
supply connecting an additional control circuit
Supplied from an -- -- -- -- ✓ • Eliminates the need for configuration and
external source via connecting an additional control circuit
IO-Link
✓ Available 1) SIRIUS 3RU21 thermal overload relays use a bimetal contactor and
-- Not available therefore do not require a control supply voltage.

Siemens IC 10 · 2023 7/79


© Siemens 2023

Protection equipment
Overload relays
General data

Features 3RU21 3RB30/3RB31 3RB20/3RB21 3RB22/3RB23 3RB24 Benefits


Other features (continued)
Overload warning -- -- -- ✓ ✓ • Indicates imminent tripping of the relay
directly on the device due to overload,
phase asymmetry or phase failure through
flickering of the LEDs or in the case of the
3RB24 as a signal through IO-Link
• Allows the imminent tripping of the relay to
be signaled
• Allows measures to be taken in time in the
event of inverse-time delayed overloading
for an extended period over the current limit
• Eliminates the need for an additional device
• Saves space in the control cabinet
• Reduces wiring outlay and costs
Analog output -- -- -- ✓ ✓ • Allows the output of an analog output signal
for actuating moving-coil measuring
instruments, feeding programmable logic
controllers or transfer to bus systems
7

• Eliminates the need for an additional


instrument transformer and signal converter
• Saves space in the control cabinet
• Reduces wiring outlay and costs
✓ Available
-- Not available

7/80 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
General data
Overview of overload relays – matching contactors
Overload Current Current Contactors (type, size, rating in kW)
relays measure- range 3RT201. 3RT202. 3RT203. 3RT204. 3RT105. 3RT106. 3RT107. 3TF68/3TF69
ment
S00 S0 S2 S3 S6 S10 S12 14
Type A 3/4/5.5/7.5 5.5/7.5/11/15/18.5 15/18.5/22/30/37 37/45/55 55/75/90 110/132/160 200/250 375/450
SIRIUS 3RU21 thermal overload relays
3RU211 Integrated 0.11 … 16 ✓ -- -- -- -- -- -- --
3RU212 Integrated 1.8 … 40 -- ✓ -- -- -- -- -- --
3RU213 Integrated 11 … 80 -- -- ✓ -- -- -- -- --
3RU214 Integrated 28 ... 100 -- -- -- ✓ -- -- -- --

3RU21
SIRIUS 3RB30 electronic overload relays1)
3RB301 Integrated 0.1 … 16 ✓ -- -- -- -- -- -- --
3RB302 Integrated 0.1 … 40 -- ✓ -- -- -- -- -- --
3RB303 Integrated 12.5 … 80 -- -- ✓ -- -- -- -- --
3RB304 Integrated 32 ... 115 -- -- -- ✓ -- -- -- --

3RB30
SIRIUS 3RB31 electronic overload relays1)
3RB311 Integrated 0.1 … 16 ✓ -- -- -- -- -- -- --
3RB312 Integrated 0.1 … 40 -- ✓ -- -- -- -- -- --
3RB313 Integrated 12.5 … 80 -- -- ✓ -- -- -- -- --

7
3RB314 Integrated 32 ... 115 -- -- -- -- -- -- --

3RB31
SIRIUS 3RB20 electronic overload relays1)
3RB205 Integrated 50 … 200 -- -- -- -- ✓ -- -- --
3RB206 Integrated 55 … 630 -- -- -- -- -- ✓ ✓ ✓
3RB201 + Integrated 630 … 820 -- -- -- -- -- -- -- ✓
3UF18

3RB20
SIRIUS 3RB21 electronic overload relays1)
3RB215 Integrated 50 … 200 -- -- -- -- ✓ -- -- --
3RB216 Integrated 55 … 630 -- -- -- -- -- ✓ ✓ ✓
3RB211 + Integrated 630 … 820 -- -- -- -- -- -- -- ✓
3UF18

3RB21
SIRIUS 3RB22 to 3RB24 electronic overload relays1)
3RB2906 0.3 … 25 ✓ ✓ -- -- -- -- -- --
3RB2283/ 3RB2906 10 … 100 ✓ ✓ ✓ ✓ -- -- -- --
3RB2383/
3RB2483 3RB2956 20 … 200 -- ✓ ✓ ✓ ✓ -- -- --
+ 3RB2966 63 … 630 -- -- -- -- -- ✓ ✓ ✓
3RB2906 630 … 820 -- -- -- -- -- -- -- ✓
+ 3UF18

3RB22, 3RB23,
3RB24
✓ Can be used 1) "Technical specifications" for the use of overload relays with trip class
-- Cannot be used  CLASS 20E, see "Short-circuit protection with fuses for motor feeders"
in theConfiguration Manual.

Siemens IC 10 · 2023 7/81


© Siemens 2023

Protection equipment
Overload relays
General data
Connection methods Voltage data
3RU2 thermal overload relays The data for 3-phase power systems according to IEC 60947-4-1
• Sizes S00 and S0: are valid for the following line system configurations:
.

- Main and auxiliary circuit: Either screw or spring-loaded Voltage Ue Line system configurations
terminals
Three-phase Three-phase
• Sizes S2 and S3: four-wire networks three-wire networks
- Main circuit: Screw terminals with box terminal
- Auxiliary circuit: Either screw or spring-loaded terminals
3RB3 electronic overload relays

IC01_00703
• Sizes S00 and S0:

IC01_00709
- Main and auxiliary circuit: Either screw or spring-loaded
terminals
• Sizes S2 and S3: V V V
- Main circuit: Screw terminals with box terminal or as straight-
through transformer 230 -- 230
- Auxiliary circuit: Either screw or spring-loaded terminals 400 230/400 400
440 260/440 440
3RB2 electronic overload relays
500 -- 500
3RB20 and 3RB21 overload relays: 690 400/690 690 (only as from size S3)
• Size S6: 1 000 -- 1 000
- Main circuit: With busbar connection or as straight-through
-- Not specified
transformer
- Auxiliary circuit: Either screw or spring-loaded terminals
• Sizes S10/S12:
- Main circuit: With busbar connection
- Auxiliary circuit: Either screw or spring-loaded terminals
7

3RB22 to 3RB24 evaluation modules:


• Screw or spring-loaded terminals
3RB29 current measuring modules:
• Up to size S3: Straight-through transformers
• As from size S6:
- Main circuit: With busbar connection
- Auxiliary circuit: Either screw or spring-loaded terminals

Screw terminals

Spring-loaded terminals

Busbar connections

Straight-through transformers

The various terminals and straight-through


transformers are indicated in the corresponding tables
by the symbols shown on orange backgrounds.

7/82 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
3RU2 for standard applications

■ Overview
More information
Homepage, see www.siemens.com/sirius-control Application Manual for switching devices with IE3 and IE4 motors, see
Industry Mall, see www.siemens.com/product?3RU2 https://support.industry.siemens.com/cs/ww/en/view/94770820
TIA Selection Tool Cloud (TST Cloud), see Equipment Manual, see
www.siemens.com/tstcloud/?node=ThermalOverloadRelay https://support.industry.siemens.com/cs/ww/en/view/60298164
Conversion tool, see www.siemens.com/conversion-tool Characteristics and certificates, see
https://support.industry.siemens.com/cs/ww/en/ps/16271

1 Stand-alone assembly support for 3RU2 and 3RB3


1
2 3RU21 thermal overload relay
Sizes S00 to S3
Mountable accessories
3 Module for Remote RESET

IC01_00659
4 Cable release with holder for RESET
5 Sealable cover
2 6 Mechanical RESET
7 Pushbutton

7
3
5
4

Mountable accessories for 3RU thermal overload relay

Siemens IC 10 · 2023 7/83


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
3RU2 for standard applications
3RU21 thermal overload relays up to 100 A have been designed
to provide inverse-time delayed protection for loads with normal
starting against impermissibly high temperature rises due to
6 overload or phase failure.
An overload or phase failure results in an increase of the
motor current beyond the set rated motor current. Via heating

IC01_00403a
elements, this current rise heats up the bimetal strips inside
the device which then bend and as a result trigger the auxiliary
contacts by means of a tripping mechanism. The auxiliary
contacts then switch off the load by means of a contactor.
5 The break time depends on the ratio between the tripping
1
current and the current setting Ie and is stored in the form of
4 a long-term stable tripping characteristic curve, see
2
Characteristic curves.
3 The "tripped" status is signaled by means of a switch position
indicator. The relay is reset manually or automatically after
a recovery time has elapsed.
The 3RU2 thermal overload relays are suitable for operation with
1 Switch position indicator and TEST function of the wiring: frequency converters.
Indicates a trip and enables the wiring test.
The devices are manufactured in accordance with
2 Motor current setting: environmental guidelines and contain environmentally friendly
Setting the device to the rated motor current is easy with the large
rotary knob. and reusable materials. They comply with all important
worldwide standards and approvals.
3 Connecting terminals:
Depending on the device version, the connecting terminals are Use in hazardous areas
screw terminals or spring-loaded terminals for the main and
auxiliary circuits. The 3RU2 overload relays are certified in accordance with both
4 STOP button: the European Explosion Protection Directive (ATEX) and the
7

If the STOP button is pressed, the NC contact is opened. This International Explosion Protection Standard (IECEx), see
switches off the contactor downstream. The NC contact is closed
again when the button is released. Certificates.
5 Selector switch for Manual/Automatic RESET and RESET button:
With this switch you can choose between Manual and Automatic
RESET. A device set to Manual RESET can be reset locally by
pressing the RESET button. A Remote RESET is possible using the
RESET modules (accessories), which are independent of size.
6 Connection for mounting onto contactors:
Optimally adapted in electrical, mechanical and design terms to the
contactors. The overload relay can be connected directly to the
contactor using these pins. Stand-alone installation is possible as
an alternative (in conjunction with a terminal support for stand-alone
installation).
A sealable transparent cover can be optionally mounted (accessory).
It secures the motor current setting against adjustment.

SIRIUS 3RU2136-4.B0 thermal overload relay


Article number scheme
Product versions Article number
Thermal overload relays 3RU2 @ @ @ – @ @ @ @
Device type e.g. 1 = CLASS 10, 1 NO + 1 NC @
Size, rated operational current e.g. 16 = 16 A (7.5 kW) for size S00 @@
and power
Setting range for overload release e.g. 0A = 0.11 ... 0.16 A @@
Connection methods e.g. B = screw terminals @
Installation type e.g. 0 = mounting on contactor @
Example 3RU2 1 1 6 – 0 A B 0
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

7/84 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
3RU2 for standard applications

■ Benefits
The most important features and benefits of the 3RU21 thermal
overload relays are listed in the overview table (see "General
data", page 7/76 onwards).

■ Application
Industries Ambient conditions
The 3RU21 thermal overload relays are suitable for customers 3RU21 thermal overload relays compensate temperature
from all industries who want to guarantee optimum inverse-time in the temperature range from -40 to +60 °C according to
delayed protection of their electrical loads (e.g. motors) under IEC 60947-4-1. At temperatures from +60 to +70 °C, the upper
normal starting conditions (CLASS 10, 10A). set value of the setting range has to be reduced by a specific
factor.
Application
Use of SIRIUS protection devices in conjunction with
The 3RU21 thermal overload relays have been designed for the IE3 and IE4 motors
protection of three-phase and single-phase AC and DC motors.
Note:
If single-phase AC or DC loads are to be protected by the 3RU21
thermal overload relays, all three bimetal strips must be heated. For the use of 3RU21 thermal overload relays in conjunction with
For this purpose, all main conducting paths of the relay must be highly efficient IE3 and IE4 motors, please observe the
connected in series. information on dimensioning and configuring,
see Application Manual.
For more information, see page 1/8.

■ Technical specifications

7
More information
System Manual for modular system, see Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60311318 https://support.industry.siemens.com/cs/ww/en/view/60298164
Configuration Manual for load feeders, see Technical specifications, see
https://support.industry.siemens.com/cs/ww/en/view/39714188 https://support.industry.siemens.com/cs/ww/en/ps/16270/td

The following technical information is intended to provide an


initial overview of the various types of devices and functions.

Type 3RU2116 3RU2126 3RU2136 3RU2146


Size S00 S0 S2 S3
H

Dimensions (W x H x D)
(overload relay with stand-alone installation
D

W
support)
• Screw terminals mm 45 x 89 x 80 45 x 97 x 95 55 x 105 x 117 70 x 106 x 124
• Spring-loaded terminals mm 45 x 102 x 79 45 x 114 x 95 55 x 105 x 117 70 x 106 x 124
General data
Tripping in the event of Overload and phase failure
Trip class according to IEC 60947-4-1 CLASS 10 10, 10A
Phase failure sensitivity Yes
Overload warning No
Reset and recovery
• Reset options after tripping Manual, Auto and Remote RESET
(Remote RESET in conjunction with the appropriate accessories)
• Recovery time
- For Automatic RESET min. Depends on the strength of the tripping current and characteristic
- For Manual RESET min. Depends on the strength of the tripping current and characteristic
- For Remote RESET min. Depends on the strength of the tripping current and characteristic
Features
• Display of operating state on device Yes, by means of TEST function/switch position indicator slide
• TEST function Yes
• RESET button Yes
• STOP button Yes
Protection of motors in hazardous environments
• Certificate of suitability/explosion protection type according to DMT 98 ATEX G 001 II (2) GD
ATEX Directive 2014/34/EU IECEx BVS 15.0046
• According to international standard IECEx see https://support.industry.siemens.com/cs/ww/en/ps/16270/cert

Siemens IC 10 · 2023 7/85


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
3RU2 for standard applications

Type 3RU2116 3RU2126 3RU2136 3RU2146


Size S00 S0 S2 S3

H
Dimensions (W x H x D)
(overload relay with stand-alone installation

D
W
support)
• Screw terminals mm 45 x 89 x 80 45 x 97 x 95 55 x 105 x 117 70 x 106 x 124
• Spring-loaded terminals mm 45 x 102 x 79 45 x 114 x 95 55 x 105 x 117 70 x 106 x 124
General data (continued)
Ambient temperature
• Storage/transport °C -55 ... +80
• Operation °C -40 ... +70
• Temperature compensation °C Up to +60
• Permissible rated current at
- Temperature inside control cabinet 60 °C % 100 (current reduction is required above +60 °C)
- Temperature inside control cabinet 70 °C % 87
Repeat terminals
• Coil repeat terminals Yes Not required
• Auxiliary contact repeat terminals Yes Not required
Degree of protection IP on the front according to IEC 60529 IP20 (screw terminals and spring-loaded terminals)
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching from the front (screw and spring-loaded terminals)
Shock resistance with sine according to IEC 60068-2-27 g/ms 15/11 (auxiliary contacts 95/96 and 97/98: 8 g/11 ms)
Electromagnetic compatibility (EMC)
• Interference immunity Not relevant
• Emitted interference Not relevant
Installation altitude above sea level m Up to 2 000
Mounting position The diagrams show the permissible mounting positions for mounting on contactors
7

and stand-alone installation. For mounting position in the hatched area, a setting
correction of 10% must be implemented.
Stand-alone installation:

45° 0° 45°
e x 1,1 e x 1,1
90° 90°
135° 135° NSB0_01364

e x 1,1

Contactor + overload relay:


0° 0°
22,5° 22,5°

135° 135° NSB0_01363a

e x 1,1

Type of mounting For mounting on contactor or stand-alone installation with terminal support,
screw and snap-on mounting on DIN rail.

7/86 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
3RU2 for standard applications

Type 3RU2116 3RU2126 3RU2136 3RU2146


Size S00 S0 S2 S3
Main circuit
Rated insulation voltage Ui V 690 1 000
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 6 8
Rated operational voltage Ue V 690
Type of current
• Direct current Yes
• Alternating current Yes, frequency range up to 400 Hz
Current setting A 0.11 ... 0.16 1.8 ... 2.5 11 ... 16 28 ... 40
to to to to
A 11 ... 16 34 ... 40 70 ... 80 80 ... 100
Power loss per unit (max.) W 4.8 ... 7.5 5.7 ... 9.6 10.5 ... 18.9 13.5 ... 21
Short-circuit protection
• With fuse without contactor See "Selection and ordering data", pages 7/89 ... 7/92
• With fuse and contactor "Short-Circuit Protection with Fuses/Motor Starter Protectors for Motor Feeders",
see Configuration Manual.
Protective separation between main and auxiliary
conducting paths
According to IEC 60947-1
• Screw terminals or ring cable lug connections V 440 690: Setting 690
range  25 A
• Spring-loaded terminals V 440 440: Setting 690
range  25 A
Conductor cross-sections of main circuit

7
Connection type Screw terminals Screw terminals
with box terminal
Terminal screw M3, Pozidriv size 2 M4, Pozidriv size 2 M6, Pozidriv size 2 4 mm Allen screw
Operating devices mm  5 ... 6  5 ... 6  5 ... 6 4 mm Allen screw
Prescribed tightening torque Nm 0.8 ... 1.2 2 ... 2.5 3 ... 4.5 4.5 ... 6
Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 2 x (0.5 ... 1.5)1); 2 x (1 ... 2.5)1), 2 x (2.5 ... 35)1), 2 x (2.5 ... 16)1),
2 x (0.75 ... 2.5)1), 2 x (2.5 ... 10)1) 1 x (2.5 ... 50)1) 2 x (10 ... 50)1),
max. 2 x 4 1 x (10 ... 70)1)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)1), 2 x (1 ... 2.5)1); 2 x (1 ... 25)1), 2 x (2.5 ... 35)1),
2 x (0.75 ... 2.5)1) 2 x (2.5 ... 6)1), 1 x (1 ... 35)1) 1 x (2.5 ... 50)1)
max. 1 x 10
• AWG cables, solid or stranded AWG 2 x (20 ... 16)1), 2 x (16 ... 12)1), 2 x (18 ... 2)1), 2 x (10 ... 1/0)1),
2 x (18 ... 14)1), 2 x (14 ... 8)1) 1 x (18 ... 1)1) 1 x (10 ... 2/0)1)
2 x 12
Removable box terminals2)
• With copper bars3) mm -- -- -- 2 x 12 x 4
• With cable lugs4)
- Terminal screw -- -- -- M6
- Prescribed tightening torque Nm -- -- -- 4.5 ... 6
- Usable ring cable lugs d3 mm -- -- -- d2 = min. 6.3
d2 d3 = max. 19
I201_12740

Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5 and 3.5 x 0.5


Conductor cross-sections (min./max.),
one conductor can be connected
• Solid or stranded mm2 1 x (0.5 ... 4) 1 x (1 ... 10) --
• Finely stranded without end sleeve mm2 1 x (0.5 ... 2.5) 1 x (1 ... 6) --
• Finely stranded with end sleeve (DIN 46228) mm2 1 x (0.5 ... 2.5) 1 x (1 ... 6) --
• AWG cables, solid or stranded AWG 1 x (20 ... 12) 1 x (18 ... 8) --
• Max. external diameter of the conductor insulation mm 3.6 6.4 --
1) 3)
If two different conductor cross-sections are connected to one clamping If bars larger than 12 mm x 10 mm are connected, a 3RT2946-4EA2 cover
point, both cross-sections must be in the range specified. is needed to maintain the required phase clearance, see page 7/94.
2) Cable lug and busbar connection possible after removing the box 4) If conductors larger than 25 mm2 are connected, the 3RT2946-4EA2 cover
terminals. is needed to maintain the required phase clearance, see page 7/94.

Siemens IC 10 · 2023 7/87


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
3RU2 for standard applications

Type 3RU2116 3RU2126 3RU2136 3RU2146


Size S00 S0 S2 S3
Auxiliary circuit
Number of NO contacts 1
Number of NC contacts 1
Auxiliary contacts – Assignment 1 NO for the signal "tripped";
1 NC for disconnecting the contactor
Rated insulation voltage Ui V 690
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 6
Contact rating of the auxiliary contacts
• NC, NO contacts with alternating current AC-15,
rated operational current Ie at Ue
- 24 V A 3
- 120 V A 3
- 125 V A 3
- 230 V A 2
- 400 V A 1
- 600 V A 0.75
- 690 V A 0.75
• NC, NO contacts with direct current DC-13,
rated operational current Ie at Ue
- 24 V A 1
- 110 V A 0.22
- 125 V A 0.22
- 220 V A 0.11
• Contact reliability (suitability for PLC control; 17 V, 5 mA) Yes
Short-circuit protection
7

• With fuse
- Operational class gG A 6
- Quick A 10
• With miniature circuit breaker (C characteristic) A 6 (up to Ik  0.5 kA; U  260 V)
Reliable operational voltage for protective separation between V 440
auxiliary conducting paths
According to IEC 60947-1
CSA, UL and UR rated data
Auxiliary circuit – Switching capacity B600, R300
Conductor cross-sections for auxiliary circuit
Connection type Screw terminals

Terminal screw M3, Pozidriv size 2


Operating devices mm  5 ... 6
Prescribed tightening torque Nm 0.8 ... 1.2
Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1)
• AWG cables, solid or stranded AWG 2 x (20 ... 16)1), 2 x (18 ... 14)1)
Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5 and 3.5 x 0.5


Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 2 x (0.5 ... 2.5)
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
• Max. external diameter of the conductor insulation mm 3.6
1) If two different conductor cross-sections are connected to one clamping
point, both cross-sections must be in the range specified.

7/88 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
IE3 ready IE4 ready IE3/IE4 ready 3RU2 for standard applications

■ Selection and ordering data


3RU21 thermal overload relays for mounting on contactor1), sizes S00 and S0, CLASS 10
Features and technical specifications: • TEST function
• Connection methods • STOP button
Main and auxiliary circuit: Either screw or spring-loaded • Sealable covers (optional accessory)
terminals
• Overload and phase failure protection PU (UNIT, SET, M) = 1
• Auxiliary contacts 1 NO + 1 NC PS* = 1 unit
PG = 41F
• Manual and Automatic RESET
• Switch position indicator

3RU2116-..B0 3RU2116-..C0 3RU2126-..B0 3RU2126-..C0

Size Trip class Rated power for Current setting Short-circuit Screw terminals Spring-loaded
contac- three-phase value of the protection with fuse, terminals
tor motors, rated inverse-time type of
value2) delayed overload coordination "2",

7
release operational
class gG3)
Article No. Price Article No. Price
CLASS kW A A per PU per PU
Size S00
S00 10 0.04 0.11 ... 0.16 0.5 3RU2116-0AB0 3RU2116-0AC0
10 0.06 0.14 ... 0.2 1 3RU2116-0BB0 3RU2116-0BC0
10 0.06 0.18 ... 0.25 1 3RU2116-0CB0 3RU2116-0CC0
10 0.09 0.22 ... 0.32 1.6 3RU2116-0DB0 3RU2116-0DC0
10 0.09 0.28 ... 0.4 2 3RU2116-0EB0 3RU2116-0EC0
10 0.12 0.35 ... 0.5 2 3RU2116-0FB0 3RU2116-0FC0
10 0.18 0.45 ... 0.63 2 3RU2116-0GB0 3RU2116-0GC0
10 0.18 0.55 ... 0.8 4 3RU2116-0HB0 3RU2116-0HC0
10 0.25 0.7 ... 1 4 3RU2116-0JB0 3RU2116-0JC0
10 0.37 0.9 ... 1.25 4 3RU2116-0KB0 3RU2116-0KC0
10 0.55 1.1 ... 1.6 6 3RU2116-1AB0 3RU2116-1AC0
10 0.75 1.4 ... 2 6 3RU2116-1BB0 3RU2116-1BC0
10 0.75 1.8 ... 2.5 10 3RU2116-1CB0 3RU2116-1CC0
10 1.1 2.2 ... 3.2 10 3RU2116-1DB0 3RU2116-1DC0
10 1.5 2.8 ... 4 16 3RU2116-1EB0 3RU2116-1EC0
10 1.5 3.5 ... 5 20 3RU2116-1FB0 3RU2116-1FC0
10 2.2 4.5 ... 6.3 20 3RU2116-1GB0 3RU2116-1GC0
10 3 5.5 ... 8 25 3RU2116-1HB0 3RU2116-1HC0
10 4 7 ... 10 35 3RU2116-1JB0 3RU2116-1JC0
10 5.5 9 ... 12.5 35 3RU2116-1KB0 3RU2116-1KC0
10 7.5 11 ... 16 40 3RU2116-4AB0 3RU2116-4AC0
Size S0
S0 10 0.75 1.8 ... 2.5 10 3RU2126-1CB0 3RU2126-1CC0
10 1.1 2.2 ... 3.2 10 3RU2126-1DB0 3RU2126-1DC0
10 1.5 2.8 ... 4 16 3RU2126-1EB0 3RU2126-1EC0
10 1.5 3.5 ... 5 20 3RU2126-1FB0 3RU2126-1FC0
10 2.2 4.5 ... 6.3 20 3RU2126-1GB0 3RU2126-1GC0
10 3 5.5 ... 8 25 3RU2126-1HB0 3RU2126-1HC0
10 4 7 ... 10 35 3RU2126-1JB0 3RU2126-1JC0
10 5.5 9 ... 12.5 35 3RU2126-1KB0 3RU2126-1KC0
10 7.5 11 ... 16 40 3RU2126-4AB0 3RU2126-4AC0
10 7.5 14 ... 20 50 3RU2126-4BB0 3RU2126-4BC0
10 11 17 ... 22 63 3RU2126-4CB0 3RU2126-4CC0
10 11 20 ... 25 63 3RU2126-4DB0 3RU2126-4DC0
10 15 23 ... 28 63 3RU2126-4NB0 3RU2126-4NC0
10 15 27 ... 32 80 3RU2126-4EB0 3RU2126-4EC0
10 18.5 30 ... 36 80 3RU2126-4PB0 3RU2126-4PC0
10 18.5 34 ... 40 80 3RU2126-4FB0 3RU2126-4FC0
1) 3)
With the appropriate terminal supports (see page 7/93), the 3RU2 overload Maximum protection by fuse only for overload relays, type of
relays for mounting on contactors can also be installed as stand-alone units. coordination "2". For fuse values in connection with contactors,
2)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual see Configuration Manual.
starting and rated data of the motor to be protected must be considered
when selecting the units.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/89
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
3RU2 for standard applications IE3 ready IE4 ready IE3/IE4 ready

3RU21 thermal overload relays for mounting on contactor1), sizes S2 and S3, CLASS 10 or 10A
Features and technical specifications: • TEST function
• Connection methods • STOP button
- Main circuit: Screw terminals with box terminal • Sealable covers (optional accessory)
- Auxiliary circuit: Either screw or spring-loaded terminals
• Overload and phase failure protection PU (UNIT, SET, M) = 1
• Auxiliary contacts 1 NO + 1 NC PS* = 1 unit
PG = 41F
• Manual and Automatic RESET
• Switch position indicator

3RU2136-..B0 3RU2136-..D0 3RU2146-4.B0 3RU2146-4.D0

Size Trip class Rated power for Current setting Short-circuit Screw terminals Spring-loaded
contac- three-phase value of the protection with fuse, terminals
tor motors, rated inverse-time type of (on auxiliary current
value2) delayed overload coordination "2", side)
7

release operational
class gG3)
Article No. Price Article No. Price
CLASS kW A A per PU per PU
Size S2
S2 10 3 5.5 ... 8 25 3RU2136-1HB0 3RU2136-1HD0
10 4 7 ... 10 35 3RU2136-1JB0 3RU2136-1JD0
10 5.5 9 ... 12.5 35 3RU2136-1KB0 3RU2136-1KD0
10 7.5 11 ... 16 40 3RU2136-4AB0 3RU2136-4AD0
10 7.5 14 ... 20 50 3RU2136-4BB0 3RU2136-4BD0
10 11 18 ... 25 63 3RU2136-4DB0 3RU2136-4DD0
10 15 22 ... 32 80 3RU2136-4EB0 3RU2136-4ED0
10 18.5 28 ... 40 80 3RU2136-4FB0 3RU2136-4FD0
10 22 36 ... 45 100 3RU2136-4GB0 3RU2136-4GD0
10 22 40 ... 50 100 3RU2136-4HB0 3RU2136-4HD0
10 30 47 ... 57 100 3RU2136-4QB0 3RU2136-4QD0
10 30 54 ... 65 125 3RU2136-4JB0 3RU2136-4JD0
10A 37 62 ... 73 160 3RU2136-4KB0 3RU2136-4KD0
10A 37 70 ... 80 160 3RU2136-4RB0 3RU2136-4RD0
Size S3
S3 10 18.5 28 ... 40 80 3RU2146-4FB0 3RU2146-4FD0
10 22 36 ... 50 125 3RU2146-4HB0 3RU2146-4HD0
10 30 45 ... 63 125 3RU2146-4JB0 3RU2146-4JD0
10 37 57 ... 75 160 3RU2146-4KB0 3RU2146-4KD0
10 45 70 ... 90 160 3RU2146-4LB0 3RU2146-4LD0
10 45 80 ... 1004) 200 3RU2146-4MB0 3RU2146-4MD0
1) 3)
With the appropriate terminal supports (see page 7/93), the 3RU2 overload Maximum protection by fuse only for overload relays, type of
relays for mounting on contactors can also be installed as stand-alone units. coordination "2". For fuse values in connection with contactors,
2) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual see Configuration Manual.
starting and rated data of the motor to be protected must be considered 4) For overload relays > 100 A, see 3RB2 electronic overload relays,
when selecting the units. page 7/107 onwards.

* You can order this quantity or a multiple thereof.


7/90 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
IE3 ready IE4 ready IE3/IE4 ready 3RU2 for standard applications
3RU21 thermal overload relays for stand-alone installation, sizes S00 and S0, CLASS 10
Features and technical specifications: • TEST function
• Connection methods • STOP button
Main and auxiliary circuit: Either screw or spring-loaded • Sealable covers (optional accessory)
terminals
• Overload and phase failure protection PU (UNIT, SET, M) = 1
• Auxiliary contacts 1 NO + 1 NC PS* = 1 unit
PG = 41F
• Manual and Automatic RESET
• Switch position indicator

3RU2116-..B1 3RU2116-..C1 3RU2126-4.B1 3RU2126-4.C1

Size Trip class Rated power for Current setting Short-circuit Screw terminals Spring-loaded
contac- three-phase value of the protection with fuse, terminals
tor motors, rated inverse-time type of
value1) delayed overload coordination "2",
release operational
class gG2)

7
Article No. Price Article No. Price
CLASS kW A A per PU per PU
Size S00
S00 10 0.04 0.11 ... 0.16 0.5 3RU2116-0AB1 3RU2116-0AC1
10 0.06 0.14 ... 0.2 1 3RU2116-0BB1 3RU2116-0BC1
10 0.06 0.18 ... 0.25 1 3RU2116-0CB1 3RU2116-0CC1
10 0.09 0.22 ... 0.32 1.6 3RU2116-0DB1 3RU2116-0DC1
10 0.09 0.28 ... 0.4 2 3RU2116-0EB1 3RU2116-0EC1
10 0.12 0.35 ... 0.5 2 3RU2116-0FB1 3RU2116-0FC1
10 0.18 0.45 ... 0.63 2 3RU2116-0GB1 3RU2116-0GC1
10 0.18 0.55 ... 0.8 4 3RU2116-0HB1 3RU2116-0HC1
10 0.25 0.7 ... 1 4 3RU2116-0JB1 3RU2116-0JC1
10 0.37 0.9 ... 1.25 4 3RU2116-0KB1 3RU2116-0KC1
10 0.55 1.1 ... 1.6 6 3RU2116-1AB1 3RU2116-1AC1
10 0.75 1.4 ... 2 6 3RU2116-1BB1 3RU2116-1BC1
10 0.75 1.8 ... 2.5 10 3RU2116-1CB1 3RU2116-1CC1
10 1.1 2.2 ... 3.2 10 3RU2116-1DB1 3RU2116-1DC1
10 1.5 2.8 ... 4 16 3RU2116-1EB1 3RU2116-1EC1
10 1.5 3.5 ... 5 20 3RU2116-1FB1 3RU2116-1FC1
10 2.2 4.5 ... 6.3 20 3RU2116-1GB1 3RU2116-1GC1
10 3 5.5 ... 8 25 3RU2116-1HB1 3RU2116-1HC1
10 4 7 ... 10 35 3RU2116-1JB1 3RU2116-1JC1
10 5.5 9 ... 12.5 35 3RU2116-1KB1 3RU2116-1KC1
10 7.5 11 ... 16 40 3RU2116-4AB1 3RU2116-4AC1
Size S0
S0 10 7.5 14 ... 20 50 3RU2126-4BB1 3RU2126-4BC1
10 11 17 ... 22 63 3RU2126-4CB1 3RU2126-4CC1
10 11 20 ... 25 63 3RU2126-4DB1 3RU2126-4DC1
10 15 23 ... 28 63 3RU2126-4NB1 3RU2126-4NC1
10 15 27 ... 32 80 3RU2126-4EB1 3RU2126-4EC1
10 18.5 30 ... 36 80 3RU2126-4PB1 3RU2126-4PC1
10 18.5 34 ... 40 80 3RU2126-4FB1 3RU2126-4FC1
1) 2)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Maximum protection by fuse only for overload relays, type of
starting and rated data of the motor to be protected must be considered coordination "2". For fuse values in connection with contactors,
when selecting the units. see Configuration Manual.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/91
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
3RU2 for standard applications IE3 ready IE4 ready IE3/IE4 ready

3RU21 thermal overload relays for stand-alone installation, sizes S2 and S3, CLASS 10 or 10A
Features and technical specifications: • TEST function
• Connection methods • STOP button
- Main circuit: Screw terminals with box terminal • Sealable covers (optional accessory)
- Auxiliary circuit: Either screw or spring-loaded terminals
• Auxiliary contacts 1 NO + 1 NC PU (UNIT, SET, M) = 1
• Manual and Automatic RESET PS* = 1 unit
• Switch position indicator PG = 41F

3RU2136-4.B1 3RU2136-4.D1 3RU2146-4.B1 3RU2146-4.D1

Size Trip class Rated power for Current setting Short-circuit Screw terminals Spring-loaded
contac- three-phase value of the protection with fuse, terminals
tor motors, rated inverse-time type of
value1) delayed overload coordination "2",
release operational
class gG2)
7

Article No. Price Article No. Price


CLASS kW A A per PU per PU
Size S2
S2 10 15 22 ... 32 80 3RU2136-4EB1 3RU2136-4ED1
10 18.5 28 ... 40 80 3RU2136-4FB1 3RU2136-4FD1
10 22 36 ... 45 100 3RU2136-4GB1 3RU2136-4GD1
10 22 40 ... 50 100 3RU2136-4HB1 3RU2136-4HD1
10 30 47 ... 57 100 3RU2136-4QB1 3RU2136-4QD1
10 30 54 ... 65 125 3RU2136-4JB1 3RU2136-4JD1
10A 37 62 ... 73 160 3RU2136-4KB1 3RU2136-4KD1
10A 37 70 ... 80 160 3RU2136-4RB1 3RU2136-4RD1
Size S3
S3 10 30 45 ... 63 125 3RU2146-4JB1 3RU2146-4JD1
10 37 57 ... 75 160 3RU2146-4KB1 3RU2146-4KD1
10 45 70 ... 90 160 3RU2146-4LB1 3RU2146-4LD1
10 45 80 ... 1003) 200 3RU2146-4MB1 3RU2146-4MD1
1) 3)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual For overload relays > 100 A, see 3RB2 electronic overload relays,
starting and rated data of the motor to be protected must be considered page 7/107 onwards.
when selecting the units.
2)
Maximum protection by fuse only for overload relays, type of
coordination "2". For fuse values in connection with contactors,
see Configuration Manual.

* You can order this quantity or a multiple thereof.


7/92 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
Accessories

■ Overview
The following optional accessories are available for the • Electrical Remote RESET module in three voltage variants
3RU21 thermal overload relays: (for all sizes)
• Size-specific terminal support for stand-alone installation, • Sealable cover (for all sizes)
in sizes S00 and S0 also with spring-loaded terminals • Size-specific terminal covers for devices with screw terminals
• Mechanical RESET (for all sizes) (box terminals)
• Cable release for resetting devices which are difficult to
access (for all sizes)

■ Selection and ordering data


Version Size Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Terminal supports for stand-alone installation


Terminal supports for overload relays with Screw terminals
screw terminals
For separate mounting of the overload relays; S00 3RU2916-3AA01 1 1 unit 41F
screw and snap-on mounting on DIN rail S0 3RU2926-3AA01 1 1 unit 41F
S2 3RU2936-3AA01 1 1 unit 41F
3RU2916- 3RU2916-
3AA01 3AC01 S3 3RU2946-3AA01 1 1 unit 41F
Terminal supports for overload relays with Spring-loaded
spring-loaded terminals terminals
For separate mounting of the overload relays; S00 3RU2916-3AC01 1 1 unit 41F
screw and snap-on mounting on DIN rail

7
S0 3RU2926-3AC01 1 1 unit 41F

3RU2926- 3RU2926-
3AA01 3AC01

3RU2936-3AA01

3RU2946-3AA01
Mechanical RESET
Resetting plungers, holders and formers S00 ... S3 3RU2900-1A 1 1 unit 41F

3RU2900-1A
Pushbuttons with extended stroke S00 ... S3 3SU1200-0FB10-0AA0 1 1 unit 41J
(12 mm), IP65,  22 mm

3SU1200-0FB10-0AA0
Extension plungers S00 ... S3 3SU1900-0KG10-0AA0 1 1 unit 41J
For compensation of the distance between
the pushbutton and the resetting plunger of
the relay

3SU1900-0KG10-0AA0

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/93
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RU2 thermal overload relays
Accessories

Version Size Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Cable releases with holder for RESET


For  6.5 mm holes in the control panel;
max. control panel thickness 8 mm
• Length 400 mm S00 ... S3 3RU2900-1B 1 1 unit 41F
• Length 600 mm S00 ... S3 3RU2900-1C 1 1 unit 41F

3RU2900-1B
Modules for Remote RESET, electrical
Operating range 0.85 ... 1.1 x Us,
Power consumption 80 VA AC, 70 W DC,
ON period 0.2 ... 4 s,
Switching frequency 60/h
• 24 ... 30 V AC/DC S00 ... S3 3RU1900-2AB71 1 1 unit 41F
• 110 ... 127 V AC/DC S00 ... S3 3RU1900-2AF71 1 1 unit 41F
• 220 ... 250 V AC/DC S00 ... S3 3RU1900-2AM71 1 1 unit 41F
3RU1900-2AM71
Sealable covers
For covering the setting knobs S00 ... S3 3RV2908-0P 100 10 units 41E
7

3RV2908-0P
Terminal covers
Covers for contactors with cable lug and S3 3RT1946-4EA1 1 1 unit 41B
busbar connections
For complying with the phase clearances
and as touch protection if box terminal is
removed

3RT1946-4EA1
Covers for devices with screw terminals Screw terminals
(box terminals)
Additional touch protection for fastening to the
box terminals
• Main current level S2 3RT2936-4EA2 1 1 unit 41B
3RT2936-4EA2
S3 3RT2946-4EA2 1 1 unit 41B

General accessories
Version Size Color For Article No. Price PU PS* PG
overload per PU (UNIT,
relays SET, M)

Tools for opening spring-loaded terminals


Spring-loaded
terminals
Screwdrivers Length approx. Titanium Main and 3RA2908-1A 1 1 unit 41B
For all SIRIUS 200 mm, gray/ auxiliary
3RA2908-1A devices with 3.0 mm x 0.5 mm black, circuit
spring-loaded partially connection:
terminals insulated 3RU2
Blank labels
Unit labeling 20 mm x 7 mm Titanium 3RU2 3RT2900-1SB20 100 340 41B
plates1) gray units
For SIRIUS
devices
Adhesive 19 mm x 6 mm Titanium 3RB2 3RT2900-1SB60 100 3 060 41B
IC01_00181

labels gray units


For SIRIUS
devices
3RT2900-1SB20
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


7/94 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
3RB30, 3RB31 for standard applications

■ Overview
More information
Homepage, see www.siemens.com/sirius-control Application Manual for switching devices with IE3 and IE4 motors, see
Industry Mall, see www.siemens.com/product?3RB3 https://support.industry.siemens.com/cs/ww/en/view/94770820
TIA Selection Tool Cloud (TST Cloud), see Equipment Manual, see
www.siemens.com/tstcloud/?node=ElectronicOverloadRelay https://support.industry.siemens.com/cs/ww/en/view/60298164
Conversion tool, see www.siemens.com/conversion-tool Characteristics and certificates, see
https://support.industry.siemens.com/cs/ww/en/ps/16276

1 Stand-alone assembly support for 3RU2 and 3RB3


1
2 3RB30, 3RB31 electronic overload relay,
sizes S00 to S3
Mountable accessories
3 Cable release with holder for RESET

IC01_00649
4 Sealable cover
5 Mechanical RESET
2 6 Pushbutton

7
4
3

Mountable accessories for 3RB30 and 3RB31 electronic overload relays

Siemens IC 10 · 2023 7/95


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
3RB30, 3RB31 for standard applications
The 3RB30/3RB31 electronic overload relays up to 115 A with
internal power supply have been designed for current-
dependent protection of loads with normal and heavy starting,
8 and to protect against excessive temperature rises due to
overload, phase asymmetry or phase failure. An overload, phase

IC01_00406
asymmetry or phase failure result in an increase of the motor
current beyond the set rated motor current. This current rise is
detected by the current transformers integrated into the devices
and evaluated by corresponding solid-state circuits which then
output a pulse to the auxiliary contacts. The auxiliary contacts
7
1 then switch off the load by means of a contactor. The break time
6 depends on the ratio between the tripping current and the
2 current setting Ie and is stored in the form of a long-term stable
5 tripping characteristic curve, see Characteristics.
3
In addition to inverse-time delayed protection of loads against
4
excessive temperature rises due to overload, phase asymmetry
and phase failure, the 3RB31 electronic overload relays also
allow internal ground-fault detection (not possible in conjunction
with contactor assemblies for star-delta (wye-delta) starting).
1 Switch position indicator and TEST function of the wiring: This provides protection of loads against incomplete ground
Indicates a trip and enables the wiring test. faults due to damage to the insulation material, moisture,
2 Trip class setting/internal ground-fault detection (only 3RB31): condensed water, etc.
Using the rotary switch you can set the required trip class and
activate the internal ground-fault detection dependent on the
The "tripped" status is signaled by means of a switch position
starting conditions. indicator. The relay is reset manually or automatically after the
recovery time has elapsed.
3 Solid-state test (device test):
Enables a test of all important device components and functions. The 3RB3 electronic overload relays are suitable for operation
4 Connecting terminals (removable terminal block for auxiliary with frequency converters.
circuits):
7

Depending on the device version, the connecting terminals are The devices are manufactured in accordance with environ-
screw terminals or spring-loaded terminals for the main and mental guidelines and contain environmentally friendly and
auxiliary circuits. reusable materials. They comply with all important worldwide
5 Selector switch for Manual/Automatic RESET: standards and approvals.
With the slide switch you can choose between Manual and Automatic
RESET. For 3RB20 and 3RB21 overload relays in sizes S6 to S10/S12,
6 Motor current setting: see page 7/114 onwards.
Setting the device to the rated motor current is easy with the large
rotary knob. Use in hazardous areas
7 A device set to Manual RESET can be reset locally by pressing the The 3RB30/3RB31 electronic overload relays are suitable for the
RESET button. On 3RB31 overload relays an electrical Remote
RESET is integrated. overload protection of motors with the following types of
protection:
8 Connection for mounting onto contactors:
Optimally adapted in electrical, mechanical and design terms to the • II (2) G[Ex e] [Ex d] [Ex px]
3RT2 contactors. The overload relay can be connected directly
using these connection pins. Stand-alone installation is possible as • II (2) D[Ex t] [Ex p]
an alternative (in conjunction with a terminal support for EC type-examination certificate for Group II, Category (2) G/D
stand-alone installation).
exists. It has the number PTB 09 ATEX 3001.
A sealable transparent cover can be optionally mounted
(accessory). It secures the motor current setting against adjustment.

SIRIUS 3RB3133-4.B0 electronic overload relay

7/96 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
3RB30, 3RB31 for standard applications
Article number scheme
Product versions Article number
Electronic overload relays 3RB3 @ @ @ – @ @ @ @
Device type e.g. 0 = standard device, with internal supply, @
for three-phase loads
Size, rated operational current e.g. 1 = 16 A (7.5 kW) for size S00 @
and power
Version of the Automatic RESET, e.g. 6 = switchable between Manual/Automatic RESET @
electrical Remote RESET
Trip class (CLASS) e.g. 1 = CLASS 10E @
Setting range of the overload release e.g. R = 0.1 ... 0.4 A @
Connection methods e.g. B = screw terminals for main and auxiliary circuits @
Installation type e.g. 0 = for mounting onto contactors @
Example 3RB3 0 1 6 – 1 R B 0
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

■ Benefits
The most important features and benefits of the 3RB30/3RB31
electronic overload relays are listed in the overview table
(see "General Data" page 7/76 onwards.)

■ Application

7
Industries The 3RU21 thermal overload relay or the 3RB22/3RB23/3RB24
electronic overload relay can be used for single-phase AC
The 3RB30/3RB31 electronic overload relays are suitable for loads. For DC loads we recommend the 3RU21 thermal
customers from all industries who want to guarantee optimum overload relay.
inverse-time delayed protection of their electrical loads
(e.g. motors) under normal and heavy starting conditions Ambient conditions
(CLASS 5E to 30E), minimize project completion times,
inventories and energy consumption, and optimize plant The devices are insensitive to external influences such as
availability and maintenance management. shocks, corrosive ambient conditions, aging and temperature
fluctuations.
Application
For the temperature range from -25 to +60 °C, the 3RB30/3RB31
The 3RB30/3RB31 electronic overload relays have been electronic overload relays compensate the temperature in
designed for the protection of three-phase motors in sinusoidal accordance with IEC 60947-4-1.
50/60 Hz voltage networks. The relays are not suitable for the
protection of single-phase AC or DC loads. Use of SIRIUS protection devices in conjunction with
IE3 and IE4 motors
Note:
For the use of 3RB30/3RB31 electronic overload relays in
conjunction with highly efficient IE3 and IE4 motors, please
observe the information on dimensioning and configuring, see
Application Manual.
For more information, see page 1/8.

Siemens IC 10 · 2023 7/97


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
3RB30, 3RB31 for standard applications

■ Technical specifications
More information
System Manual for modular system, see Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60311318 https://support.industry.siemens.com/cs/ww/en/view/60298164
Configuration Manual for load feeders, see Technical specifications, see
https://support.industry.siemens.com/cs/ww/en/view/39714188 https://support.industry.siemens.com/cs/ww/en/ps/16276/td

The following technical information is intended to provide an


initial overview of the various types of devices and functions.
Type 3RB3016, 3RB3113 3RB3026, 3RB3123 3RB3036, 3RB3133 3RB3046, 3RB3143
Size S00 S0 S2 S3
H

Dimensions (W x H x D)
(overload relay with stand-alone installation

D
W
support)
• Screw terminals mm 45 x 89 x 80 45 x 97 x 94 55 x 105 x 117 70 x 106 x 124
• Spring-loaded terminals mm 45 x 102 x 80 45 x 116 x 95 55 x 105 x 117 70 x 106 x 124
General data
Tripping in the event of Overload, phase failure, and phase asymmetry
+ ground fault (for 3RB31 only)
Trip class according to IEC 60947-4-1 CLASS 3RB30: 10E, 20E;
3RB31: 5E, 10E, 20E or 30E adjustable
Phase failure sensitivity Yes
Reset and recovery
• Reset options after tripping Manual and Automatic RESET, 3RB31 has an integrated connection for electrical
Remote RESET (24 V DC)
7

• Recovery time
- For Automatic RESET Approx. 3 min
- For Manual RESET Immediately
- For Remote RESET Immediately
Features
• Display of operating state on device Yes, by means of switch position indicator slide
• TEST function Yes, test of electronics by pressing the TEST button/
test of auxiliary contacts and wiring of control circuit by actuating the switch position
indicator slide/self-monitoring
• RESET button Yes
• STOP button No
Protection and operation of explosion-proof motors
Certificate of suitability/explosion protection type according to PTB 09 ATEX 3001
ATEX Directive 2014/34/EU II (2) G[Ex e] [Ex d] [Ex px]
II (2) G[Ex t] [Ex p]
see https://support.industry.siemens.com/cs/ww/en/view/40591327
Ambient temperatures
• Storage/transport °C -40 ... +80
• Operation °C -25 ... +60
• Temperature compensation °C +60
• Permissible rated current at
- Temperature inside control cabinet 60 °C % 100
- Temperature inside control cabinet 70 °C % On request
Repeat terminals
• Coil repeat terminals Yes Not required
• Auxiliary contact repeat terminals Yes Not required
Degree of protection IP on the front according to IEC 60529
• Screw terminals/spring-loaded terminals IP20
• Straight-through transformers -- IP20
Touch protection on the front according to IEC 60529
• Screw terminals/spring-loaded terminals Finger-safe for vertical touching from the front
• Straight-through transformers -- Finger-safe for vertical touching from
the front
Shock resistance with sine according to IEC 60068-2-27 g/ms 15/11 15/11
(signaling contact 97/98 in position (signaling contact 97/98 in position
"tripped": 9 g/11 ms) "tripped": 8 g/11 ms)

7/98 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
3RB30, 3RB31 for standard applications

Type 3RB3016, 3RB3113 3RB3026, 3RB3123 3RB3036, 3RB3133 3RB3046, 3RB3143


Size S00 S0 S2 S3

H
Dimensions (W x H x D)
(overload relay with stand-alone installation

D
W
support)
• Screw terminals mm 45 x 89 x 80 45 x 97 x 94 55 x 105 x 117 70 x 106 x 124
• Spring-loaded terminals mm 45 x 102 x 80 45 x 116 x 95 55 x 105 x 117 70 x 106 x 124
General data (continued)
Electromagnetic compatibility (EMC) – Interference immunity
• Conductor-related interference
- Burst according to IEC 61000-4-4 kV 2 (power ports), 1 (signal port)
(corresponds to degree of severity 3)
- Surge according to IEC 61000-4-5 kV 2 (line to earth), 1 (line to line)
(corresponds to degree of severity 3)
• Electrostatic discharge according to IEC 61000-4-2 kV 8 (air discharge), 6 (contact discharge)
(corresponds to degree of severity 3)
• Field-related interference according to IEC 61000-4-3 V/m 10
(corresponds to degree of severity 3)
Electromagnetic compatibility (EMC) – Emitted interference Degree of severity B according to EN 55011 (CISPR 11)
and EN 55022 (CISPR 22)
Installation altitude above sea level m Up to 2 000
Mounting position Any
Type of mounting Direct mounting/stand-alone installation with terminal support

Type 3RB3016, 3RB3113 3RB3026, 3RB3123 3RB3036, 3RB3133 3RB3046, 3RB3143

7
Size S00 S0 S2 S3
Main circuit
Rated insulation voltage Ui V 690 690 1 000
(pollution degree 3) 1 000 with straight-
through transformer
Rated impulse withstand voltage Uimp kV 6 6 8
8 with straight-
through transformer
Rated operational voltage Ue V 690 690 1 000
1 000 with straight-
through transformer
Type of current
• Direct current No
• Alternating current Yes, 50/60 Hz 5%
Current setting A 0.1 ... 0.4 0.1 ... 0.4 12.5 ... 50 12.5 ... 50
to to and and
A 4 ... 16 10 ... 40 20 ... 80 32 ... 115
Heavy starting See Equipment Manual
Power loss per unit (max.) W 0.1 ... 1.1 0.1 ... 4.5 0.5 ... 4.6 0.9 ... 4.6
Short-circuit protection
• With fuse without contactor See "Selection and ordering data", pages 7/102 ... 7/104
• With fuse and contactor "Short-Circuit Protection with Fuses/Motor Starter Protectors for Motor Feeders",
see Configuration Manual.
Protective separation between main and auxiliary
conducting paths
According to IEC 60947-1 (pollution degree 2)
• For systems with grounded neutral point V 690
• For systems with ungrounded neutral point V 600

Siemens IC 10 · 2023 7/99


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
3RB30, 3RB31 for standard applications

Type 3RB3016, 3RB3113 3RB3026, 3RB3123 3RB3036, 3RB3133 3RB3046, 3RB3143


Size S00 S0 S2 S3
Conductor cross-sections of main circuit
Connection type Screw terminals Screw
terminals
with box
terminal
Terminal screw M3, Pozidriv size 2 M4, Pozidriv size 2 4 mm Allen screw
Operating devices mm  5 ... 6  5 ... 6 4 mm Allen screw
Prescribed tightening torque Nm 0.8 ... 1.2 2 ... 2.5 4.5 ... 6
Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 2 x (0.5 ... 1.5)1), 2 x (1 ... 2.5)1), 1 x (1 ... 50)1), 2 x (2.5 ... 16)1),
2 x (0.75 ... 2.5)1), 2 x (2.5 ... 10)1) 2 x (1 ... 35)1) 2 x (10 ... 50)1),
2 x (0.5 ... 4)1) 1 x (10 ... 70)1)
• Finely stranded with end sleeve mm2 2 x (0.5 ... 1.5)1), 2 x (1 ... 2.5)1), 2 x (1 ... 25)1), 2 x (2.5 ... 35)1),
(DIN 46228) 2 x (0.75 ... 2.5)1) 2 x (2.5 ... 6)1), 1 x (1 ... 35)1) 1 x (2.5 ... 50)1)
max. 1 x 10
• AWG cables, solid or stranded AWG 2 x (20 ... 16)1), 2 x (16 ... 12)1), 2 x (18 ... 2)1), 2 x (10 ... 1/0)1),
2 x (18 ... 14)1), 2 x (14 ... 8)1) 1 x (18 ... 1)1) 1 x (10 ... 2/0)1)
2 x 12
Removable box terminals2)
• With copper bars3) mm -- -- -- 2 x 12 x 4
• With cable lugs4)
- Terminal screw -- -- -- M6
- Prescribed tightening torque Nm -- -- -- 4.5 ... 6
- Usable ring cable lugs d3 mm -- -- -- d2 = min. 6.3
7

d2 d3 = max. 19
I201_12740

Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5 and 3.5 x 0.5


Conductor cross-sections (min./max.),
one conductor can be connected
• Solid or stranded mm2 1 x (0.5 ... 4) 1 x (1 ... 10) --
• Finely stranded without end sleeve mm2 1 x (0.5 ... 2.5) 1 x (1 ... 6) --
• Finely stranded with end sleeve mm2 1 x (0.5 ... 2.5) 1 x (1 ... 6) --
(DIN 46228)
• AWG cables, solid or stranded AWG 1 x (20 ... 12) 1 x (18 ... 8) --
• Max. external diameter of the conductor mm 3.6 6.4 --
insulation
Connection type Straight-through transformers

Diameter of opening mm -- 15 18
1) If two different conductor cross-sections are connected to one clamping 3) If bars larger than 12 mm x 10 mm are connected, a 3RT2946-4EA2 cover
point, both cross-sections must be in the range specified. is needed to maintain the required phase clearance, see page 7/106.
2) 4)
Cable lug and busbar connection possible after removing the box terminals. If conductors larger than 25 mm2 are connected, the 3RT2946-4EA2 cover
is needed to maintain the required phase clearance, see page 7/106.

7/100 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
3RB30, 3RB31 for standard applications

Type 3RB3016, 3RB3113 3RB3026, 3RB3123 3RB3036, 3RB3133 3RB3046, 3RB3143


Size S00 S0 S2 S3
Auxiliary circuit
Number of NO contacts 1
Number of NC contacts 1
Auxiliary contacts – Assignment 1 NO for the signal "tripped";
1 NC for disconnecting the contactor
Rated insulation voltage Ui V 300
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 4
Auxiliary contacts – Contact rating
• NC, NO contact with alternating current AC-14/AC-15,
rated operational current Ie at Ue
- 24 V A 4
- 120 V A 4
- 125 V A 4
- 250 V A 3
• NC, NO contacts with direct current DC-13,
rated operational current Ie at Ue
- 24 V A 2
- 60 V A 0.55
- 110 V A 0.3
- 125 V A 0.3
- 250 V A 0.11
• Conventional thermal current Ith A 5
• Contact reliability Yes
(suitability for PLC control; 17 V, 5 mA)
Short-circuit protection

7
• With fuse, operational class gG A 6
Ground-fault protection (only 3RB31) The information refers to sinusoidal residual currents at 50/60 Hz.
• Tripping value I > 0.75 x Imotor
• Operating range I Lower current setting < Imotor < 3.5 x upper current setting
• Response time ttrip (in steady-state condition) s <1
Integrated electrical Remote RESET (only 3RB31)
Connecting terminals A3, A4 24 V DC, max. 200 mA for approx. 20 ms, then < 10 mA
Protective separation between auxiliary conducting paths V 300
according to IEC 60947-1

Type 3RB3016, 3RB3113 3RB3026, 3RB3123 3RB3036, 3RB3133 3RB3046, 3RB3143


Size S00 S0 S2 S3
CSA, UL and UR rated data
Auxiliary circuit – Switching capacity B600, R300
Conductor cross-sections for auxiliary circuit
Connection type Screw terminals

Terminal screw M3, Pozidriv size 2


Operating devices mm  5 ... 6
Prescribed tightening torque Nm 0.8 ... 1.2
Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 1 x (0.5 ... 4)1), 2 x (0.5 ... 2.5)1)
2
• Finely stranded with end sleeve (DIN 46228) mm 1 x (0.5 ... 2.5)1), 2 x (0.5 ... 1.5)1)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5


Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.25 ... 1.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.25 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (24 ... 16)
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must be in the range specified.

Siemens IC 10 · 2023 7/101


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
3RB30, 3RB31 for standard applications IE3 ready IE4 ready IE3/IE4 ready

■ Selection and ordering data


3RB30 electronic overload relays, CLASS 10E
Features and technical specifications: • Internal power supply
• Connection methods • Auxiliary contacts 1 NO + 1 NC
- Sizes S00 and S0 • Manual and Automatic RESET
Main and auxiliary circuit: Either screw or spring-loaded
terminals • Switch position indicator
- Sizes S2 and S3 • TEST function and self-monitoring
Main circuit: Screw terminals with box terminal or as straight- • Sealable covers (optional accessory)
through transformer
Auxiliary circuit: Either screw or spring-loaded terminals PU (UNIT, SET, M) = 1
• Overload protection, phase failure protection and asymmetry PS* = 1 unit
protection PG = 41G

3RB3016-1.B0 3RB3026-1.B0 3RB3036-1.B0 3RB3036-1.W1 3RB3046-1.B0 3RB3046-1.W1

Size Rated power for Current setting value Short-circuit protection Screw terminals Spring-loaded
contactor three-phase of the inverse-time with fuse, type of terminals
7

motors, rated delayed overload coordination "2",


value1) release operational class gG2)
Article No. Price Article No. Price
kW A A per PU per PU
Size S00
S00 Devices for mounting on contactor3)
0.04 ... 0.09 0.1 ... 0.4 4 3RB3016-1RB0 3RB3016-1RE0
0.12 ... 0.37 0.32 ... 1.25 6 3RB3016-1NB0 3RB3016-1NE0
0.37 ... 1.5 1…4 20 3RB3016-1PB0 3RB3016-1PE0
1.5 ... 5.5 3 … 12 50 3RB3016-1SB0 3RB3016-1SE0
2.2 ... 7.5 4 ... 16 50 3RB3016-1TB0 3RB3016-1TE0
Size S0
S0 Devices for mounting on contactor3)
0.04 ... 0.09 0.1 ... 0.4 4 3RB3026-1RB0 3RB3026-1RE0
0.12 ... 0.37 0.32 ... 1.25 6 3RB3026-1NB0 3RB3026-1NE0
0.37 ... 1.5 1…4 20 3RB3026-1PB0 3RB3026-1PE0
1.5 ... 5.5 3 … 12 50 3RB3026-1SB0 3RB3026-1SE0
3 ... 11 6 … 25 63 3RB3026-1QB0 3RB3026-1QE0
5.5 ... 18.5 10 ... 40 80 3RB3026-1VB0 3RB3026-1VE0
Size S2
S2 Devices with screw terminals (main current side)
and for mounting on contactor3)
7.5 ... 22 12.5 ... 50 200 3RB3036-1UB0 3RB3036-1UD0
11 ... 37 20 ... 80 250 3RB3036-1WB0 3RB3036-1WD0
Devices with straight-through transformer for stand-alone
installation
7.5 ... 22 12.5 ... 50 200 3RB3036-1UW1 3RB3036-1UX1
11 ... 37 20 ... 80 250 3RB3036-1WW1 3RB3036-1WX1
Size S3
S3 Devices with screw terminals (main current side)
and for mounting on contactor3)
7.5 ... 22 12.5 ... 50 200 3RB3046-1UB0 3RB3046-1UD0
18.5 ... 55 32 ... 115 315 3RB3046-1XB0 3RB3046-1XD0
Devices with straight-through transformer for stand-alone
installation
7.5 ... 22 12.5 ... 50 200 3RB3046-1UW1 3RB3046-1UX1
18.5 ... 55 32 ... 115 315 3RB3046-1XW1 3RB3046-1XX1
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual Note:
starting and rated data of the motor to be protected must be considered
when selecting the units. For reliable operational current, note derating information,
2) see Equipment Manual.
Maximum protection by fuse only for overload relays, type of coordination "2".
For fuse values in connection with contactors, see Configuration Manual.
3) With the appropriate terminal supports (see page 7/105), these overload
relays can also be installed as stand-alone units.

* You can order this quantity or a multiple thereof.


7/102 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
IE3 ready IE4 ready IE3/IE4 ready 3RB30, 3RB31 for standard applications
3RB30 electronic overload relays, CLASS 20E
Features and technical specifications: • Auxiliary contacts 1 NO + 1 NC
• Connection methods • Manual and Automatic RESET
- Sizes S00 and S0 • Switch position indicator
Main and auxiliary circuit: Either screw or spring-loaded
terminals • TEST function and self-monitoring
- Sizes S2 and S3 • Sealable covers (optional accessory)
Main circuit: Screw terminals with box terminal or as straight-
through transformer PU (UNIT, SET, M) = 1
Auxiliary circuit: Either screw or spring-loaded terminals PS* = 1 unit
PG = 41G
• Overload protection, phase failure protection and asymmetry
protection
• Internal power supply

3RB3016-2.B0 3RB3026-2.B0 3RB3036-2.B0 3RB3036-2.W1 3RB3046-2.B0 3RB3046-2.W1

Size Rated power for Current setting value Short-circuit protection Screw terminals Spring-loaded
contactor three-phase of the inverse-time with fuse, type of terminals
motors, rated delayed overload coordination "2",

7
value1) release operational class gG2)
Article No. Price Article No. Price
kW A A per PU per PU
Size S00
S00 Devices for mounting on contactor3)
0.04 ... 0.09 0.1 ... 0.4 4 3RB3016-2RB0 3RB3016-2RE0
0.12 ... 0.37 0.32 ... 1.25 6 3RB3016-2NB0 3RB3016-2NE0
0.37 ... 1.5 1…4 20 3RB3016-2PB0 3RB3016-2PE0
1.5 ... 5.5 3 … 12 50 3RB3016-2SB0 3RB3016-2SE0
2.2 ... 7.5 4 ... 16 50 3RB3016-2TB0 3RB3016-2TE0
Size S0
S0 Devices for mounting on contactor3)
0.04 ... 0.09 0.1 ... 0.4 4 3RB3026-2RB0 3RB3026-2RE0
0.12 ... 0.37 0.32 ... 1.25 6 3RB3026-2NB0 3RB3026-2NE0
0.37 ... 1.5 1…4 20 3RB3026-2PB0 3RB3026-2PE0
1.5 ... 5.5 3 … 12 50 3RB3026-2SB0 3RB3026-2SE0
3 ... 11 6 … 25 63 3RB3026-2QB0 3RB3026-2QE0
5.5 ... 18.5 10 ... 40 80 3RB3026-2VB0 3RB3026-2VE0
Size S2
S2 Devices with screw terminals (main current side)
and for mounting on contactor3)
7.5 ... 22 12.5 ... 50 200 3RB3036-2UB0 3RB3036-2UD0
11 ... 37 20 ... 80 250 3RB3036-2WB0 3RB3036-2WD0
Devices with straight-through transformer for stand-alone
installation
7.5 ... 22 12.5 ... 50 200 3RB3036-2UW1 3RB3036-2UX1
11 ... 37 20 ... 80 250 3RB3036-2WW1 3RB3036-2WX1
Size S3
S3 Devices with screw terminals (main current side)
and for mounting on contactor3)
7.5 ... 22 12.5 ... 50 200 3RB3046-2UB0 3RB3046-2UD0
18.5 ... 55 32 ... 115 315 3RB3046-2XB0 3RB3046-2XD0
Devices with straight-through transformer for stand-alone
installation
7.5 ... 22 12.5 ... 50 200 3RB3046-2UW1 3RB3046-2UX1
18.5 ... 55 32 ... 115 315 3RB3046-2XW1 3RB3046-2XX1
1) 3)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual With the appropriate terminal supports (see page 7/105), these overload
starting and rated data of the motor to be protected must be considered relays can also be installed as stand-alone units.
when selecting the units.
2) Maximum protection by fuse only for overload relays, type of coordination "2".
For fuse values in connection with contactors, see Configuration Manual.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/103
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
3RB30, 3RB31 for standard applications IE3 ready IE4 ready IE3/IE4 ready

3RB31 electronic overload relays, CLASS 5E, 10E, 20E or 30E (adjustable)
Features and technical specifications: • Internal power supply
• Connection methods • Auxiliary contacts 1 NO + 1 NC
- Sizes S00 and S0 • Manual and Automatic RESET
Main and auxiliary circuit: Either screw or spring-loaded
terminals • Electrical Remote RESET integrated
- Sizes S2 and S3 • Switch position indicator
Main circuit: Screw terminals with box terminal or as straight- • TEST function and self-monitoring
through transformer
Auxiliary circuit: Either screw or spring-loaded terminals • Sealable covers (optional accessory)
• Overload protection, phase failure protection and asymmetry PU (UNIT, SET, M) = 1
protection PS* = 1 unit
• Internal ground-fault detection (activatable) PG = 41G

3RB3113-4.B0 3RB3123-4.B0 3RB3133-4.B0 3RB3133-4.W1 3RB3143-4.B0 3RB3143-4.W1

Size Rated power for Current setting value Short-circuit protection Screw terminals Spring-loaded
contactor three-phase motors, of the inverse-time with fuse, type of terminals
rated value1) delayed overload coordination "2",
operational class gG2)
7

release
Article No. Price Article No. Price
kW A A per PU per PU
Size S00
S00 Devices for mounting on contactor3)
0.04 ... 0.09 0.1 ... 0.4 4 3RB3113-4RB0 3RB3113-4RE0
0.12 ... 0.37 0.32 ... 1.25 6 3RB3113-4NB0 3RB3113-4NE0
0.37 ... 1.5 1…4 20 3RB3113-4PB0 3RB3113-4PE0
1.5 ... 5.5 3 … 12 50 3RB3113-4SB0 3RB3113-4SE0
2.2 ... 7.5 4 ... 16 50 3RB3113-4TB0 3RB3113-4TE0
Size S0
S0 Devices for mounting on contactor3)
0.04 ... 0.09 0.1 ... 0.4 4 3RB3123-4RB0 3RB3123-4RE0
0.12 ... 0.37 0.32 ... 1.25 6 3RB3123-4NB0 3RB3123-4NE0
0.37 ... 1.5 1…4 20 3RB3123-4PB0 3RB3123-4PE0
1.5 ... 5.5 3 … 12 50 3RB3123-4SB0 3RB3123-4SE0
3 ... 11 6 … 25 63 3RB3123-4QB0 3RB3123-4QE0
5.5 ... 18.5 10 ... 40 80 3RB3123-4VB0 3RB3123-4VE0
Size S2
S2 Devices with screw terminals (main current side)
and for mounting on contactor3)
7.5 ... 22 12.5 ... 50 200 3RB3133-4UB0 3RB3133-4UD0
11 ... 37 20 ... 80 250 3RB3133-4WB0 3RB3133-4WD0
Devices with straight-through transformer for stand-
alone installation
7.5 ... 22 12.5 ... 50 200 3RB3133-4UW1 3RB3133-4UX1
11 ... 37 20 ... 80 250 3RB3133-4WW1 3RB3133-4WX1
Size S3
S3 Devices with screw terminals (main current side)
and for mounting on contactor3)
7.5 ... 22 12.5 ... 50 200 3RB3143-4UB0 3RB3143-4UD0
18.5 ... 55 32 ... 115 315 3RB3143-4XB0 3RB3143-4XD0
Devices with straight-through transformer for stand-
alone installation
7.5 ... 22 12.5 ... 50 200 3RB3143-4UW1 3RB3143-4UX1
18.5 ... 55 32 ... 115 315 3RB3143-4XW1 3RB3143-4XX1
1) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
2)
Maximum protection by fuse only for overload relays, type of coordination "2".
For fuse values in connection with contactors, see Configuration Manual.
3)
With the appropriate terminal supports (see page 7/105), these overload
relays can also be installed as stand-alone units.

* You can order this quantity or a multiple thereof.


7/104 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
Accessories

■ Overview
The following optional accessories are available for the • Cable release for resetting devices which are difficult to
3RB30/3RB31 electronic overload relays: access (for all sizes)
• Size-specific terminal support for stand-alone installation, • Sealable cover (for all sizes)
in sizes S00 and S0 also with spring-loaded terminals • Size-specific terminal covers for devices with screw terminals
• Mechanical RESET (for all sizes) (box terminals)

■ Selection and ordering data


Version Size Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Terminal supports for stand-alone installation


Terminal supports for overload relays with Screw terminals
screw terminals
For separate mounting of the overload relays; S00 3RU2916-3AA01 1 1 unit 41F
screw and snap-on mounting on DIN rail S0 3RU2926-3AA01 1 1 unit 41F
S2 3RU2936-3AA01 1 1 unit 41F
3RU2916- 3RU2916-
3AA01 3AC01 S3 3RU2946-3AA01 1 1 unit 41F
Terminal supports for overload relays with Spring-loaded
spring-loaded terminals terminals
For separate mounting of the overload relays; S00 3RU2916-3AC01 1 1 unit 41F
screw and snap-on mounting on DIN rail S0 3RU2926-3AC01 1 1 unit 41F

7
3RU2926- 3RU2926-
3AA01 3AC01

3RU2936-3AA01

3RU2946-3AA01
Mechanical RESET
Resetting plungers, holders and formers S00 ... S3 3RB3980-0A 1 1 unit 41F

3RB3980-0A
Pushbuttons with extended stroke S00 ... S3 3SU1200-0FB10-0AA0 1 1 unit 41J
(12 mm), IP65,  22 mm

3SU1200-0FB10-0AA0
Extension plungers S00 ... S3 3SU1900-0KG10-0AA0 1 1 unit 41J
For compensation of the distance between
the pushbutton and the resetting plunger of
the relay

3SU1900-0KG10-0AA0

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/105
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB3 electronic overload relays
Accessories

Version Size Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Cable releases with holder for RESET


For  6.5 mm holes in the control panel;
max. control panel thickness 8 mm
• Length 400 mm S00 ... S3 3RB3980-0B 1 1 unit 41F
• Length 600 mm S00 ... S3 3RB3980-0C 1 1 unit 41F

3RB3980-0B
Sealable covers
For covering the setting knobs S00 ... S3 3RB3984-0 1 1 unit 41F

3RB3984-0
Terminal covers
Covers for contactors with cable lug and S3 3RT1946-4EA1 1 1 unit 41B
busbar connections
For complying with the phase clearances
and as touch protection if box terminal is
removed
7

3RT1946-4EA1
Covers for devices with screw terminals Screw terminals
(box terminals)
Additional touch protection for fastening to the
box terminals
• Main current level S2 3RT2936-4EA2 1 1 unit 41B
3RT2936-4EA2
S3 3RT2946-4EA2 1 1 unit 41B

General accessories
Version Size Color For Article No. Price PU PS* PG
overload per PU (UNIT,
relays SET, M)

Tools for opening spring-loaded terminals


Spring-loaded
terminals
Screwdrivers Length approx. Titanium Main and 3RA2908-1A 1 1 unit 41B
For all SIRIUS 200 mm, gray/ auxiliary
3RA2908-1A devices with 3.0 mm x 0.5 mm black, circuit
spring-loaded partially connection:
terminals insulated 3RB3
Blank labels
Unit labeling 20 mm x 7 mm Titanium 3RB3 3RT2900-1SB20 100 340 41B
plates1) gray units
For SIRIUS
devices
Adhesive 19 mm x 6 mm Titanium 3RB2 3RT2900-1SB60 100 3 060 41B
IC01_00181

labels gray units


For SIRIUS
devices
3RT2900-1SB20
1) PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


7/106 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB20, 3RB21 for standard applications

■ Overview
More information
Homepage, see www.siemens.com/sirius-control Application Manual for switching devices with IE3 and IE4 motors, see
Industry Mall, see www.siemens.com/product?3RB2 https://support.industry.siemens.com/cs/ww/en/view/94770820
Conversion tool, see www.siemens.com/conversion-tool Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60298164
Characteristics and certificates, see
https://support.industry.siemens.com/cs/ww/en/ps/16278

2 1 3RB2 overload relay


3
Sizes S6 to S10/S12
Mountable accessories
2 Terminal cover
3 Box terminals
4 Cable release with holder for RESET
5 Sealable cover
1 6 Mechanical RESET

IC01_00650a
7 Pushbutton

7
4 5

Mountable accessories for 3RB2 electronic overload relays (sizes S6 to S10/S12)

Siemens IC 10 · 2023 7/107


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB20, 3RB21 for standard applications
The 3RB20 and 3RB21 electronic overload relays up to 630 A
with internal power supply have been designed for inverse-time
delayed protection of loads with normal and heavy starting
8 (see Equipment Manual) against excessive temperature rises

IC01_00335b
due to overload, phase asymmetry or phase failure.
7 An overload, phase asymmetry or phase failure result in an
1 increase of the motor current beyond the set rated motor current.
6 This current rise is detected by the current transformers
2 integrated into the devices and evaluated by corresponding
solid-state circuits which then output a pulse to the auxiliary
5
3 contacts. The auxiliary contacts then switch off the load by
means of a contactor. The break time depends on the ratio
4
between the tripping current and the current setting Ie and is
stored in the form of a long-term stable tripping characteristic
curve, see Characteristics.
In addition to inverse-time delayed protection of loads against
1 Switch position indicator and TEST function of the wiring: excessive temperature rises due to overload, phase asymmetry
Indicates a trip and enables the wiring test. and phase failure, the 3RB21 electronic overload relays also
2 Trip class setting/internal ground-fault detection (only 3RB21): allow internal ground-fault detection (not possible in conjunction
Using the rotary switch you can set the required trip class and with contactor assemblies for star-delta (wye-delta) starting).
activate the internal ground-fault detection dependent on the
starting conditions. This provides protection of loads against incomplete ground
faults due to damage to the insulation material, moisture,
3 Solid-state test (device test):
Enables a test of all important device components and functions. condensed water, etc.
4 Connecting terminals (removable terminal block for auxiliary circuits): The "tripped" status is signaled by means of a switch position
The generously sized terminals permit connection of two indicator. The relay is reset manually or automatically after the
conductors with different cross-sections for the main and auxiliary
circuits. The auxiliary circuit can be connected with screw terminals recovery time has elapsed.
and alternatively with spring-loaded terminals.
The 3RB2 electronic overload relays are suitable for operation
7

5 Selector switch for Manual/Automatic RESET: with frequency converters, see Equipment Manual.
With the slide switch you can choose between Manual and
Automatic RESET. The devices are manufactured in accordance with environ-
6 Motor current setting: mental guidelines and contain environmentally friendly and
Setting the device to the rated motor current is easy with the large reusable materials. They comply with all important worldwide
rotary knob.
standards and approvals.
7 A device set to Manual RESET can be reset locally by pressing the
RESET button. On the 3RB21 overload relay a solid-state Remote For 3RB30 and 3RB31 overload relays sizes S00 to S3,
RESET is integrated. see page 7/102 onwards.
_ Connection for mounting onto contactors:
Optimally adapted in electrical, mechanical and design terms to the Use in hazardous areas
3RT1 contactors. These connecting pins can be used for direct
mounting of the overload relay to the contactor. Stand-alone The 3RB20/3RB21 electronic overload relays are suitable for
installation is possible as an alternative (partly in conjunction with a the overload protection of motors with the following types of
terminal support for stand-alone installation). protection:
• II (2) G[Ex e] [Ex d] [Ex px]
SIRIUS 3RB2153-4FW2 electronic overload relays
• II (2) D[Ex t] [Ex p]
EC type-examination certificate for Group II, Category (2)
G/D exists. It has the number PTB 06 ATEX 3001.

7/108 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB20, 3RB21 for standard applications
Article number scheme
Product versions Article number
Electronic overload relays 3RB2 @ @ @ – @ @ @ @
Device type e.g. 0 = standard device, with internal supply, @
for three-phase loads
Size, rated operational current e.g. 5 = 200 A (90 kW) for size S6 @
and power
Version of the Automatic RESET, e.g. 6 = switchable between Manual/Automatic @
electrical Remote RESET RESET
Trip class (CLASS) e.g. 1 = CLASS 10E @
Setting range of the overload release e.g. F = 5 ... 200 A @
Connection methods e.g. C = busbar connections main circuit; screw @
terminals auxiliary circuit
Installation type e.g. 2 = mounting on contactor and stand-alone @
installation
Example 3RB2 0 5 6 – 1 F C 2
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

■ Benefits
The most important features and benefits of the 3RB20/3RB21
electronic overload relays are listed in the overview table
(see "General data", page 7/76 onwards).

7
■ Application
Industries Ambient conditions
The 3RB20 and 3RB21 electronic overload relays are suitable for The devices are insensitive to external influences such as
customers from all industries who want to guarantee optimum shocks, corrosive ambient conditions, aging and temperature
inverse-time delayed protection of their electrical loads fluctuations.
(e.g. motors) under normal and heavy starting conditions
(CLASS 5E to 30E), minimize project completion times, For the temperature range from -25 to +60 °C, the 3RB20 and
inventories and energy consumption, and optimize plant 3RB21 electronic overload relays compensate the temperature
availability and maintenance management. in accordance with IEC 60947-4-1.
For the 3RB20 and 3RB21 electronic overload relays with the
Application sizes S6, S10 and S12, the upper set value of the setting range
The 3RB20 and 3RB21 electronic overload relays have been must be reduced for ambient temperatures > 50 °C by a certain
designed for the protection of three-phase motors in sinusoidal factor.
50/60 Hz voltage networks. The relays are not suitable for the
protection of single-phase AC or DC loads. Use of SIRIUS protection devices in conjunction with
IE3 and IE4 motors
The 3RU21 thermal overload relays or the 3RB22 to 3RB24
electronic overload relays can be used for single-phase Note:
AC loads. For DC loads we recommend the 3RU21 thermal For the use of 3RB20 and 3RB21 electronic overload relays in
overload relay. conjunction with highly efficient IE3 and IE4 motors, please
observe the information on dimensioning and configuring, see
Application Manual.
For more information, see page 1/8.

Siemens IC 10 · 2023 7/109


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB20, 3RB21 for standard applications

■ Technical specifications
More information
Configuration Manual for load feeders, see Technical specifications, see
https://support.industry.siemens.com/cs/ww/en/view/39714188 https://support.industry.siemens.com/cs/ww/en/ps/16278/td
Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60298164

The following technical information is intended to provide an


initial overview of the various types of devices and functions.
Type 3RB2056, 3RB2153 3RB2066, 3RB2163
Size S6 S10/S12
H

Dimensions (W x H x D) mm 120 x 119 x 155 145 x 147 x 156


(overload relay with stand-alone D
W
installation support)
General data
Tripping in the event of Overload, phase failure, and phase asymmetry
+ ground fault (for 3RB21 only)
Trip class according to IEC 60947-4-1 CLASS 3RB20: 10E or 20E;
3RB21: 5E, 10E, 20E and 30E adjustable
Phase failure sensitivity Yes
Overload warning No
Reset and recovery
• Reset options after tripping 3RB20: Manual and Automatic RESET;
3RB21: Manual, Automatic and Remote RESET
• Recovery time
7

- For Automatic RESET Approx. 3 min


- For Manual RESET Immediately
- For Remote RESET Immediately
Features
• Display of operating state on device Yes, by means of switch position indicator slide
• TEST function Yes, test of electronics by pressing the TEST button/
test of auxiliary contacts and wiring of control circuit by actuating the switch position
indicator slide/self-monitoring
• RESET button Yes
• STOP button No
Protection and operation of explosion-proof motors
Certificate of suitability/explosion protection type according to PTB 06 ATEX 3001
ATEX Directive 2014/34/EU II (2) G[Ex e] [Ex d] [Ex px]
II (2) G[Ex t] [Ex p]
See
https://support.industry.siemens.com/cs/ww/en/view/23814648
Ambient temperatures
• Storage/transport °C -40 ... +80
• Operation °C -25 ... +60
• Temperature compensation °C +60
• Permissible rated current at
- Temperature inside control cabinet 60 °C, stand-alone % 100 100 or 901)
installation
- Temperature inside control cabinet 60 °C, mounted on % 70 70
contactor
- Temperature inside control cabinet 70 °C % On request
Degree of protection IP on the front according to IEC 60529
• Screw terminals/busbar connections IP00 (IP20 with box terminal/cover)
• Straight-through transformers IP20 --
Touch protection on the front according to IEC 60529
• Screw terminals/busbar connections Finger-safe for vertical touching from the front (with box terminals/cover)
• Straight-through transformers Finger-safe for vertical touching from --
the front
1) 90% for relay with current setting range 160 A to 630 A.

7/110 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB20, 3RB21 for standard applications

Type 3RB2056, 3RB2153 3RB2066, 3RB2163


Size S6 S10/S12

H
Dimensions (W x H x D) mm 120 x 119 x 155 145 x 147 x 156
(overload relay with stand-alone installation

D
W
support)
General data (continued)
Shock resistance with sine according to IEC 60068-2-27 g/ms 15/11 (signaling contact 97/98 in position "tripped": 4 g/11 ms
Electromagnetic compatibility (EMC) – Interference immunity
• Conductor-related interference
- Burst according to IEC 61000-4-4 kV 2 (power ports), 1 (signal port)
(corresponds to degree of severity 3)
- Surge according to IEC 61000-4-5 kV 2 (line to earth), 1 (line to line)
(corresponds to degree of severity 3)
• Electrostatic discharge according to IEC 61000-4-2 kV 8 (air discharge), 6 (contact discharge)
(corresponds to degree of severity 3)
• Field-related interference according to IEC 61000-4-3 V/m 10
(corresponds to degree of severity 3)
Electromagnetic compatibility (EMC) – Emitted interference Degree of severity B according to EN 55011 (CISPR 11) and EN 55022
(CISPR 22)
Installation altitude above sea level m Up to 2 000
Mounting position Any
Type of mounting Direct mounting/stand-alone installation

Siemens IC 10 · 2023 7/111


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB20, 3RB21 for standard applications

Type 3RB2056, 3RB2153 3RB2066, 3RB2163


Size S6 S10/S12
Main circuit
Rated insulation voltage Ui (pollution degree 3) V 1 000
Rated impulse withstand voltage Uimp kV 8
Rated operational voltage Ue V 1 000
Type of current
• Direct current No
• Alternating current Yes, 50/60 Hz 5%
Current setting A 50 ... 200 55 ... 250, 160 ... 630
Power loss per unit (max.) W 0.05
Short-circuit protection
• With fuse without contactor See "Selection and ordering data", pages 7/114 ... 7/116
• With fuse and contactor "Short-Circuit Protection with Fuses/Motor Starter Protectors for Motor
Feeders", see Configuration Manual.
Protective separation between main and auxiliary conducting paths
According to IEC 60947-1 (pollution degree 2)
• For systems with grounded neutral point V 690
• For systems with ungrounded neutral point V 600
Conductor cross-sections of the main circuit
Connection type Screw terminals with box terminal

Terminal screw mm 4 mm Allen screw 5 mm Allen screw


Operating devices mm 4 mm Allen screw 5 mm Allen screw
Prescribed tightening torque Nm 10 ... 12 20 ... 22
7

Conductor cross-sections (min./max.),


one or two conductors can be connected
• Solid mm2 -- --
• Finely stranded without end sleeve mm2 With 3RT1955-4G box terminal: 2 x (50 ... 185),
2 x (1 x max. 50, 1 x max. 70), Front clamping point only:
1 x (10 ... 70); 1 x (70 ... 240);
With 3RT1956-4G box terminal: Rear clamping point only:
2 x (1 x max. 95, 1 x max. 120), 1 x (120 ... 185)
1 x (10 ... 120)
• Finely stranded with end sleeve (DIN 46228) mm2 With 3RT1955-4G box terminal: 2 x (50 ... 185),
2 x (1 x max. 50, 1 x max. 70), Front clamping point only:
1 x (10 ... 70); 1 x (70 ... 240);
With 3RT1956-4G box terminal: Rear clamping point only:
2 x (1 x max. 95, 1 x max. 120), 1 x (120 ... 185)
1 x (10 ... 120)
• Stranded mm2 With 3RT1955-4G box terminal: 2 x (70 ... 240),
2 x (max. 70), Front clamping point only:
1 x (16 ... 70); 1 x (95 ... 300);
With 3RT1956-4G box terminal: Rear clamping point only:
2 x (max. 120), 1 x (120 ... 240)
1 x (16 ... 120)
• AWG cables, solid or stranded AWG With 3RT1955-4G box terminal: 2 x (2/0 ... 500 kcmil),
2 x (max. 1/0), Front clamping point only:
1 x (6 ... 2/0); 1 x (3/0 ... 600 kcmil);
With 3RT1956-4G box terminal: Rear clamping point only:
2 x (max. 3/0), 1 x (250 kcmil ... 500 kcmil)
1 x (6 ... 250 kcmil)
• Ribbon cables (number x width x thickness) mm With 3RT1955-4G box terminal: 2 x (20 x 24 x 0.5),
2 x (6 x 15.5 x 0.8), 1 x (6 x 9 x 0.8 ... 20 x 24 x 0.5)
1 x (3 x 9 x 0.8 ... 6 x 15.5 x 0.8);
With 3RT1956-4G box terminal:
2 x (10 x 15.5 x 0.8),
1 x (3 x 9 x 0.8 ... 10 x 15.5 x 0.8)
Connection type Busbar connections

Terminal screw M8 x 25 M10 x 30


Prescribed tightening torque Nm 10 ... 14 14 ... 24
Conductor cross-sections (min./max.)
• Finely stranded with cable lug mm2 16 ... 951) 50 ... 2402)
• Stranded with cable lug mm2 25 ... 1201) 70 ... 2402)
• AWG cables, solid or stranded, with cable lug AWG 4 ... 250 kcmil 2/0 ... 500 kcmil
• With connecting bars (max. width) mm 15 25
Connection type Straight-through transformers

Diameter of opening mm 24.5 --


1) When connecting cable lugs according to DIN 46235 with conductor 2) When connecting cable lugs according to DIN 46234 for conductor cross-
cross-sections from 95 mm2, the 3RT1956-4EA1 terminal cover must be sections from 240 mm2, as well as DIN 46235 for cable cross-sections
used to ensure phase clearance, see page 7/117. from 185 mm2, the 3RT1956-4EA1 terminal cover must be used to ensure
phase clearance, see page 7/117.

7/112 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB20, 3RB21 for standard applications

Type 3RB2056, 3RB2153 3RB2066, 3RB2163


Size S6 S10/S12
Auxiliary circuit
Number of NO contacts 1
Number of NC contacts 1
Auxiliary contacts – Assignment 1 NO for the signal "tripped";
1 NC for disconnecting the contactor
Rated insulation voltage Ui V 300
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 4
Auxiliary contacts – Contact rating
• NC contact with alternating current AC-14/AC-15,
rated operational current Ie at Ue:
- 24 V A 4
- 120 V A 4
- 125 V A 4
- 250 V A 3
• NO contact with alternating current AC-14/AC-15,
rated operational current Ie at Ue:
- 24 V A 4
- 120 V A 4
- 125 V A 4
- 250 V A 3
• NC, NO contacts with direct current DC-13,
rated operational current Ie at Ue:
- 24 V A 2
- 60 V A 0.55
- 110 V A 0.3
- 125 V A 0.3

7
- 250 V A 0.11
• Conventional thermal current Ith A 5
• Contact reliability (suitability for PLC control; 17 V, 5 mA) Yes
Short-circuit protection
• With fuse, operational class gG A 6
Ground-fault protection (only 3RB21) The information refers to sinusoidal residual currents at 50/60 Hz.
• Tripping value I > 0.75 × Imotor
• Operating range I Lower current setting < Imotor < 3.5 × upper current setting
• Response time ttrip (in steady-state condition) s <1
Integrated electrical Remote RESET (only 3RB21)
Connecting terminals A3, A4 24 V DC, 100 mA, 2.4 W short-term
Protective separation between auxiliary conducting paths V 300
According to IEC 60947-1
CSA, UL and UR rated data
Auxiliary circuit – Switching capacity B300, R300
Conductor cross-sections of the auxiliary circuit
Connection type Screw terminals

Terminal screw M3, Pozidriv size 2


Operating devices mm  5 ... 6
Prescribed tightening torque Nm 0.8 ... 1.2
Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid and stranded mm2 1 x (0.5 ... 4)1), 2 x (0.5 ... 2.5)1)
• Finely stranded without end sleeve mm2 --
• Finely stranded with end sleeve (DIN 46228) mm2 1 x (0.5 ... 2.5)1), 2 x (0.5 ... 1.5)1)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5


Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid and stranded mm2 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 --
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.25 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (24 ... 16)
1) If two different conductor cross-sections are connected to one clamping
point, both cross-sections must be in the range specified.

Siemens IC 10 · 2023 7/113


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB20, 3RB21 for standard applications IE3 ready IE4 ready IE3/IE4 ready

■ Selection and ordering data


3RB20 electronic overload relays for mounting on contactors and stand-alone installation, CLASS 10E
Features and technical specifications:
• Connection methods • Overload protection, phase failure protection and asymmetry
- Size S6 protection
Main circuit: With busbar connection or as straight-through • Internal power supply
transformer (an appropriate connection kit with screws,
spring washers and nuts is enclosed with the devices with • Auxiliary contacts 1 NO + 1 NC
busbar connection) • Manual and Automatic RESET
Auxiliary circuit: Either screw or spring-loaded terminals • Switch position indicator
- Sizes S10/S12
Main circuit: With busbar connection (an appropriate • TEST function and self-monitoring
connection kit with screws, spring washers and nuts PU (UNIT, SET, M) = 1
is enclosed) PS* = 1 unit
Auxiliary circuit: Either screw or spring-loaded terminals PG = 41G

3RB2056-1FW2 3RB2066-1MF2
7

Size contactor Rated power for Current setting value Short-circuit Screw terminals Spring-loaded
three-phase motors, of the inverse-time protection with fuse, (on auxiliary current terminals
1)
rated value delayed overload type of side) (on auxiliary current
release coordination "2", side)
operational
class gG2)
Article No. Price Article No. Price
kW A A per PU per PU
Size S6
Devices with busbar connection,
for mounting onto contactor and stand-alone installation
S6 30 ... 90 50 … 200 315 3RB2056-1FC2 3RB2056-1FF2
Devices with straight-through transformer,
for mounting on contactor and stand-alone installation
For mounting 30 ... 90 50 … 200 315 3RB2056-1FW2 3RB2056-1FX2
on S6 contac-
tors with box
terminals
Size S10/S12
Devices with busbar connection,
for mounting onto contactor and stand-alone installation
S10/S12 30 ... 132 55 … 250 400 3RB2066-1GC2 3RB2066-1GF2
and size 14 90 ... 355 160 … 630 800 3RB2066-1MC2 3RB2066-1MF2
(3TF68/
3TF69)3)
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
2)
Maximum protection by fuse only for overload relays, type of
coordination "2". For fuse values in connection with contactors,
see Configuration Manual.
3) For 3TF68/3TF69 contactors, direct mounting is not possible.

* You can order this quantity or a multiple thereof.


7/114 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
IE3 ready IE4 ready IE3/IE4 ready 3RB20, 3RB21 for standard applications
3RB20 electronic overload relays for mounting on contactors and stand-alone installation, CLASS 20E
Features and technical specifications:
• Connection methods • Overload protection, phase failure protection and asymmetry
- Size S6 protection
Main circuit: With busbar connection or as straight-through • Internal power supply
transformer (an appropriate connection kit with screws,
spring washers and nuts is enclosed with the devices with • Auxiliary contacts 1 NO + 1 NC
busbar connection) • Manual and Automatic RESET
Auxiliary circuit: Either screw or spring-loaded terminals • Switch position indicator
- Sizes S10/S12
Main circuit: With busbar connection (an appropriate • TEST function and self-monitoring
connection kit with screws, spring washers and nuts PU (UNIT, SET, M) = 1
is enclosed) PS* = 1 unit
Auxiliary circuit: Either screw or spring-loaded terminals PG = 41G

3RB2056-2FW2 3RB2066-2MF2
Size contactor Rated power for Current setting value Short-circuit Screw terminals Spring-loaded
three-phase motors, of the inverse-time protection with fuse, (on auxiliary current terminals
rated value1) delayed overload type of side) (on auxiliary current

7
release coordination "2", side)
operational
class gG2)
Article No. Price Article No. Price
kW A A per PU per PU
Size S6
Devices with busbar connection,
for mounting onto contactor and stand-alone installation
S6 30 ... 90 50 … 200 315 3RB2056-2FC2 3RB2056-2FF2
Devices with straight-through transformer,
for mounting on contactor and stand-alone installation
For mounting 30 ... 90 50 … 200 315 3RB2056-2FW2 3RB2056-2FX2
on S6 contac-
tors with box
terminals
Size S10/S122)
Devices with busbar connection,
for mounting onto contactor and stand-alone installation
S10/S12 30 ... 132 55 … 250 400 3RB2066-2GC2 3RB2066-2GF2
and size 14 90 ... 355 160 … 630 800 3RB2066-2MC2 3RB2066-2MF2
(3TF68/
3TF69)3)
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
2)
Maximum protection by fuse only for overload relays, type of
coordination "2". For fuse values in connection with contactors,
see Configuration Manual.
3) For 3TF68/3TF69 contactors, direct mounting is not possible.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/115
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB20, 3RB21 for standard applications IE3 ready IE4 ready IE3/IE4 ready

3RB21 electronic overload relays for mounting on contactors and stand-alone installation, CLASS 5E, 10E, 20E and 30E
adjustable
Features and technical specifications:
• Connection methods • Overload protection, phase failure protection and asymmetry
- Size S6 protection
Main circuit: With busbar connection or as straight-through • Internal ground-fault detection (activatable)
transformer (an appropriate connection kit with screws,
spring washers and nuts is enclosed with the devices with • Internal power supply
busbar connection) • Auxiliary contacts 1 NO + 1 NC
Auxiliary circuit: Either screw or spring-loaded terminals • Manual and Automatic RESET
- Sizes S10/S12
Main circuit: With busbar connection (an appropriate • Electrical Remote RESET integrated
connection kit with screws, spring washers and nuts is • Switch position indicator
enclosed) • TEST function and self-monitoring
Auxiliary circuit: Either screw or spring-loaded terminals
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41G
7

3RB2153-4FW2 3RB2163-4MF2
Size contactor Rated power for Current setting value Short-circuit Screw terminals Spring-loaded
three-phase motors, of the inverse-time protection with fuse, (on auxiliary current terminals
rated value1) delayed overload type of side) (on auxiliary current
release coordination "2", side)
operational
class gG2)
Article No. Price Article No. Price
kW A A per PU per PU
Size S6
Devices with busbar connection,
for mounting onto contactor and stand-alone installation
S6 30 ... 90 50 … 200 315 3RB2153-4FC2 3RB2153-4FF2
Devices with straight-through transformer,
for mounting on contactor and stand-alone installation
For mounting 30 ... 90 50 … 200 315 3RB2153-4FW2 3RB2153-4FX2
on S6
contactors with
box terminals
Size S10/S122)
Devices with busbar connection,
for mounting onto contactor and stand-alone installation
S10/S12 30 ... 132 55 … 250 400 3RB2163-4GC2 3RB2163-4GF2
and size 14 90 ... 355 160 … 630 800 3RB2163-4MC2 3RB2163-4MF2
(3TF68/
3TF69)3)
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
2)
Maximum protection by fuse only for overload relays, type of
coordination "2". For fuse values in connection with contactors,
see Configuration Manual.
3) For 3TF68/3TF69 contactors, direct mounting is not possible.

* You can order this quantity or a multiple thereof.


7/116 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
Accessories for 3RB20, 3RB21

■ Overview
Overload relays for standard applications • Cable release for resetting devices which are difficult to
access (for all sizes)
The following optional accessories are available for the
3RB20 and 3RB21 electronic overload relays: • Sealable cover (for all sizes)
• Mechanical RESET (for all sizes) • Terminal covers for sizes S6 and S10/S12
• Box terminal blocks for sizes S6 and S10/S12

■ Selection and ordering data


Version Size Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Mechanical RESET
Resetting plungers, holders and formers S6 ... S12 3RB3980-0A 1 1 unit 41F

3RB3980-0A
Pushbuttons with extended stroke S6 ... S12 3SU1200-0FB10-0AA0 1 1 unit 41J
(12 mm), IP65,  22 mm

7
3SU1200-0FB10-0AA0
Extension plungers S6 ... S12 3SU1900-0KG10-0AA0 1 1 unit 41J
For compensation of the distance between
the pushbutton and the resetting plunger of
the relay

3SU1900-0KG10-0AA0
Cable releases with holder for RESET
For  6.5 mm holes in the control panel;
max. control panel thickness 8 mm
• Length 400 mm S6 ... S12 3RB3980-0B 1 1 unit 41F
• Length 600 mm S6 ... S12 3RB3980-0C 1 1 unit 41F

3RU3980-0B
Sealable covers
For covering the setting knobs S6 ... S12 3RB3984-0 1 1 unit 41F

3RB3984-0
Terminal covers
Covers for cable lugs and busbar connections
• Length 100 mm S6 3RT1956-4EA1 1 1 unit 41B
• Length 120 mm S10/S12 3RT1966-4EA1 1 1 unit 41B
Covers for box terminals
• Length 25 mm S6 3RT1956-4EA2 1 1 unit 41B
• Length 30 mm S10/S12 3RT1966-4EA2 1 1 unit 41B
3RT1956-4EA1 Covers for screw terminals S6 3RT1956-4EA3 1 1 unit 41B
Between contactor and overload relay, without S10/S12 3RT1966-4EA3 1 1 unit 41B
box terminals (1 unit required per combination)

3RT1956-4EA2
Box terminal blocks
For round and ribbon cables
• Up to 70 mm2 S61) 3RT1955-4G 1 1 unit 41B
• Up to 120 mm2 S6 3RT1956-4G 1 1 unit 41B
• Up to 240 mm2 S10/S12 3RT1966-4G 1 1 unit 41B
3RT1955-4G
1)
In the scope of supply for 3RT1054-1 contactors (55 kW).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/117
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
Accessories for 3RB20, 3RB21
General accessories
Version Size Color For Article No. Price PU PS* PG
overload per PU (UNIT,
relays SET, M)

Tools for opening spring-loaded terminals


Spring-loaded
terminals
Screwdrivers Length approx. Titanium Main and 3RA2908-1A 1 1 unit 41B
For all SIRIUS devices 200 mm, gray/ auxiliary
3RA2908-1A with spring-loaded 3.0 mm x 0.5 mm black, circuit
terminals partially connection:
insulated 3RB2
Blank labels
Unit labeling plates1) 20 mm x 7 mm Titanium 3RB2 3RT2900-1SB20 100 340 41B
For SIRIUS devices gray units
Adhesive labels 19 mm x 6 mm Titanium 3RB2 3RT2900-1SB60 100 3 060 41B
For SIRIUS devices gray units
IC01_00181

3RT2900-1SB20
1) PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).
7

* You can order this quantity or a multiple thereof.


7/118 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB22, 3RB23 for high-feature applications

■ Overview
More information
Homepage, see www.siemens.com/sirius-control Application Manual for switching devices with IE3 and IE4 motors, see
Industry Mall, see www.siemens.com/product?3RB2 https://support.industry.siemens.com/cs/ww/en/view/94770820
Operating Instructions, see
https://support.industry.siemens.com/cs/ww/en/view/21833251
Characteristics and certificates, see
https://support.industry.siemens.com/cs/ww/en/ps/16280

This current rise is detected by means of a current measuring


module (see page 7/137) and electronically evaluated by the
NSB0_01621d evaluation module which is connected to it. The evaluation
9 electronics sends a signal to the auxiliary contacts. The auxiliary
contacts then switch off the load by means of a contactor.
8 1 The break time depends on the ratio between the tripping
7 current and the current setting Ie and is stored in the form
2 of a long-term stable tripping characteristic curve, see
6 Characteristics. The "tripped" status is signaled by means
2 of a continuously illuminated red "OVERLOAD" LED.
5
The LED indicates imminent tripping of the relay due to overload,
4 3 phase asymmetry or phase failure by flickering when the limit
current has been violated. In the case of the 3RB22 and 3RB23
overload relays this warning can also be issued through auxiliary
contacts.
1 3RB2985 function expansion module:
Enables more functions to be added, e.g. internal ground-fault In addition to the described inverse-time delayed protection
detection and/or an analog output with corresponding signals.
of loads against excessive temperature rises, the 3RB22 and

7
2 Motor current and trip class setting: 3RB23 electronic overload relays also allow direct temperature
Setting the device to the motor current and to the required trip class monitoring of the motor windings (full motor protection!) by
dependent on the starting conditions is easy with the two rotary
switches. connection with broken-wire interlock of a PTC sensor circuit.
With this temperature-dependent protection, the loads can be
3 Connecting terminals (removable terminal block): protected against overheating caused, for example, indirectly
The generously sized terminals permit connection of two conductors by reduced coolant flow and which cannot be detected by
with different cross-sections for the auxiliary, control and sensor
circuits. Connection is possible with screw terminals and alterna- means of the current alone. In the event of overheating, the
tively with spring-loaded terminals. devices switch off the contactor, and thus the load, by means of
4 Test/RESET button: the auxiliary contacts. The "tripped" status is signaled by means
Enables testing of all important device components and functions, of a continuously illuminated "THERMISTOR" LED.
plus resetting of the device after a trip when Manual RESET is
selected. To protect the loads against incomplete ground faults due to
5 Selector switch for Manual/Automatic RESET: damage to the insulation, humidity, condensed water, etc., the
With this switch you can choose between Manual and Automatic 3RB22 and 3RB23 electronic overload relays offer the possibility
RESET. of internal ground fault monitoring in conjunction with a function
expansion module (for details, see Operating Instructions, not
6 Red LED "OVERLOAD":
A continuous red light signals an active overload trip; a flickering red possible in conjunction with contactor assemblies for star-delta
light signals an imminent trip (overload warning). (wye-delta) starting). In the event of a ground fault, the 3RB22
7 Red LED "THERMISTOR": and 3RB23 relays trip instantaneously.
A continuous red light signals an active thermistor trip.
The "tripped" status is signaled by means of a continuous red
8 Red LED "GND FAULT": "Ground Fault" LED. Signaling through auxiliary contacts is also
A continuous red light signals a ground-fault tripping. possible.
9 Green LED "READY": After tripping due to overload, phase asymmetry, phase failure,
A continuous green light signals that the device is working correctly.
thermistor or ground-fault tripping, the relay is reset manually or
automatically after the recovery time has elapsed.
SIRIUS 3RB22 and 3RB23 evaluation modules
In conjunction with a corresponding function expansion module,
The 3RB22 and 3RB23 electronic overload relays up to 630 A the motor current measured by the microprocessor can be
(up to 820 A possible in combination with a series transformer) output in the form of a DC 4 to 20 mA analog signal for operating
are from a modular system and comprise an evaluation unit, a rotary coil instruments or for feeding into analog inputs of
current measuring module and a connecting cable. The 3RB22 programmable logic controllers.
overload relays (with monostable auxiliary contacts) and the
3RB23 overload relays (with bistable auxiliary contacts) are
supplied from an external voltage.
They have been designed for inverse-time delayed protection
of loads with normal and heavy starting against excessive
temperature rises due to overload, phase asymmetry or phase
failure. An overload, phase asymmetry or phase failure result in
an increase of the motor current beyond the set rated motor
current.

Siemens IC 10 · 2023 7/119


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB22, 3RB23 for high-feature applications
With an additional AS-Interface analog module the current Use in hazardous areas
values can also be transferred via the AS-i bus system.
The 3RB22 electronic overload relays (monostable) with the
The 3RB2 electronic overload relays are suitable for operation 3RB29 current measuring module are suitable for the overload
with frequency converters. protection of explosion-proof motors.
The devices are manufactured in accordance with environ- EC type-examination certificate for Category (2) G/D exists.
mental guidelines and contain environmentally friendly and It has the number PTB 05 ATEX 3022.
reusable materials. They comply with all important worldwide
standards and approvals.
Article number scheme
Product versions Article number
Electronic overload relays 3RB2 @ @ @ – @ @ @ @
Device type e.g. 2 = monostable device for high-feature applications, @
supplied from external source, for three-phase loads
Size, rated operational current e.g. 8 = irrespective of size and current @
and power
Version of the Automatic RESET, e.g. 3 = switchable between Manual/Automatic RESET, @
electrical Remote RESET with integral electrical Remote RESET
Trip class (CLASS) e.g. 4 = CLASS 5E, 10E, 20E, 30E (adjustable) @
Setting range of the overload release e.g. A = none specified @
Connection methods e.g. A = screw terminals for auxiliary, control and main circuits @
Installation type e.g. 1 = stand-alone installation @
Example 3RB2 2 8 3 – 4 A A 1
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
7

versions for better understanding of the logic behind the article selection and ordering data.
numbers.

■ Benefits
The most important features and benefits of the 3RB22 and
3RB23 electronic overload relays are listed in the overview table,
see "General data", page 7/76 onwards.

■ Application
Industries Ambient conditions
The 3RB22 and 3RB23 electronic overload relays are suitable for The devices are insensitive to external influences such as
customers from all industries who want to guarantee optimum shocks, corrosive ambient conditions, aging and temperature
inverse-time delayed and temperature-dependent protection of fluctuations.
their electrical loads (e.g. motors) under normal and heavy
starting conditions (CLASS 5 to CLASS 30), minimize project For the temperature range from -25 to +60 °C, the 3RB22 and
completion times, inventories and power consumption, and 3RB23 electronic overload relays compensate the temperature
optimize plant availability and maintenance management. in accordance with IEC 60947-4-1.
Configuration notes for use of the devices below -25 °C or above
Application +60 °C on request.
The 3RB22 and 3RB23 devices have been designed for the
protection of three-phase asynchronous and single-phase Use of SIRIUS protection devices in conjunction with
AC motors. IE3 and IE4 motors

If single-phase AC motors are to be protected by the 3RB22 and Note:


3RB23 electronic overload relays, the main conducting paths of For the use of 3RB22 and 3RB23 electronic overload relays in
the current measuring modules must be series-connected. conjunction with highly efficient IE3 and IE4 motors, please
For circuit diagrams, see Operating Instructions. observe the information on dimensioning and configuring, see
Application Manual.
For more information, see page 1/8.

7/120 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB22, 3RB23 for high-feature applications

■ Technical specifications
More information
Application Manual for switching devices with IE3 and IE4 motors, see Operating Instructions, see
https://support.industry.siemens.com/cs/ww/en/view/94770820 https://support.industry.siemens.com/cs/ww/en/view/21833251
Configuration Manual for load feeders, see Technical specifications, see
https://support.industry.siemens.com/cs/ww/en/view/39714188 https://support.industry.siemens.com/cs/ww/en/ps/16280/td

The following technical information is intended to provide an


initial overview of the various types of devices and functions.
Type – Overload relay: Evaluation modules 3RB2283-4A.1 3RB2383-4A.1
Size contactor S00 ... S10/S12
H

Dimensions of evaluation modules mm 45 x 111 x 95


(W x H x D)

D
W

General data
Tripping in the event of Overload, phase failure and phase asymmetry (> 40% according to NEMA),
+ ground fault (with corresponding function expansion module) and activation of the
thermistor motor protection (with closed PTC sensor circuit)
Trip class according to IEC 60947-4-1 CLASS 5E, 10E, 20E and 30E adjustable
Phase failure sensitivity Yes
Overload warning Yes, from 1.125 × Ie for symmetrical loads
and from 0.85 × Ie for asymmetrical loads
Reset and recovery
• Reset options after tripping Manual, Automatic and Remote RESET
• Recovery time
- For Automatic RESET min. - For tripping due to overcurrent: 3 (stored permanently)

7
- For tripping by thermistor: time until the motor temperature has fallen 5 K
below the response temperature
- For tripping due to a ground fault: no Automatic RESET
- For Manual RESET min. - For tripping due to overcurrent: 3 (stored permanently)
- For tripping by thermistor: time until the motor temperature has fallen 5 K
below the response temperature
- For tripping due to a ground fault: immediately
- For Remote RESET min. - For tripping due to overcurrent: 3 (stored permanently)
- For tripping by thermistor: time until the motor temperature has fallen 5 K
below the response temperature
- For tripping due to a ground fault: immediately
Features
• Display of operating state on device Yes, with four LEDs:
- Green LED "Ready"
- Red LED "Ground Fault"
- Red LED "Thermistor"
- Red LED "Overload"
• TEST function Yes, test of LEDs, electronics, auxiliary contacts and wiring of control circuit by
pressing the button TEST/RESET/self-monitoring
• RESET button Yes, with the TEST/RESET button
• STOP button No
Protection and operation of explosion-proof motors
Certificate of suitability/explosion protection type according to PTB 05 ATEX 3022 II (2) GD --
ATEX Directive 2014/34/EU see
https://support.automation.siemens.com/WW/view/en/23115758
Ambient temperatures
• Storage/transport °C -40 ... +80
• Operation °C -25 ... +60
• Temperature compensation °C +60
• Permissible rated current
- Temperature inside control cabinet 60 °C % 100
- Temperature inside control cabinet 70 °C % On request
Degree of protection IP on the front according to IEC 60529 IP20
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching from the front
Shock resistance with sine according to IEC 60068-2-27 g/ms 15/11

Siemens IC 10 · 2023 7/121


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB22, 3RB23 for high-feature applications

Type – Overload relay: Evaluation modules 3RB2283-4A.1 3RB2383-4A.1


Size contactor S00 ... S10/S12

H
Dimensions of evaluation modules mm 45 x 111 x 95
(W x H x D)

D
W

General data (continued)


Electromagnetic compatibility (EMC) – Interference immunity
• Conductor-related interference
- Burst according to IEC 61000-4-4 kV 2 (power ports), 1 (signal port)
(corresponds to degree of severity 3)
- Surge according to IEC 61000-4-5 kV 2 (line to earth), 1 (line to line)
(corresponds to degree of severity 3)
• Electrostatic discharge according to IEC 61000-4-2 kV 8 (air discharge), 6 (contact discharge)
(corresponds to degree of severity 3)
• Field-related interference according to IEC 61000-4-3 V/m 10
(corresponds to degree of severity 3)
Electromagnetic compatibility (EMC) – Emitted interference Degree of severity A according to EN 55011 (CISPR 11) and EN 55022 (CISPR 22)
Installation altitude above sea level m Up to 2 000
Mounting position Any
Type of mounting
• Evaluation modules Stand-alone installation
• Current measuring modules Size S00 to S3: Stand-alone installation,
S6 and S10/S12: Stand-alone installation or mounting on contactors

Type – Overload relay: Evaluation modules 3RB2283-4A.1, 3RB2383-4A.1


Size contactor S00 ... S10/S12
7

Auxiliary circuit
Number of NO contacts 2
Number of NC contacts 2
Number of CO contacts --
Auxiliary contacts – Assignment • Alternative 1
- 1 NO for the signal "tripped by overload and/or thermistor",
- 1 NC for disconnecting the contactor,
- 1 NO for the signal "tripped by ground fault",
- 1 NC for disconnecting the contactor
or1)
• Alternative 2
- 1 NO for the signal "tripped by overload and/or thermistor and/or ground fault",
- 1 NC for disconnecting the contactor,
- 1 NO for overload warning,
- 1 NC for disconnecting the contactor
Rated insulation voltage Ui (pollution degree 3) V 300
Rated impulse withstand voltage Uimp kV 4
Auxiliary contacts – Contact rating
• NC, NO contact with alternating current AC-14/AC-15,
rated operational current Ie at Ue
- 24 V A 6
- 120 V A 6
- 125 V A 6
- 250 V A 3
• NC, NO contacts with direct current DC-13,
rated operational current Ie at Ue
- 24 V A 2
- 60 V A 0.55
- 110 V A 0.3
- 125 V A 0.3
- 250 V A 0.2
• Conventional thermal current Ith A 5
• Contact reliability Yes
(suitability for PLC control; 17 V, 5 mA)
Short-circuit protection
• With fuse, operational class gG A 6
• With miniature circuit breaker, C characteristic A 1.6
Protective separation between auxiliary conducting paths V 300
According to IEC 60947-1
CSA, UL and UR rated data
Auxiliary circuit – Switching capacity B300, R300
1) The assignment of auxiliary contacts may be influenced by function
expansion modules.

7/122 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB22, 3RB23 for high-feature applications

Type – Overload relay: Evaluation modules 3RB2283-4A.1, 3RB2383-4A.1


Size contactor S00 ... S10/S12
Control circuit
Rated insulation voltage Ui V 300
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 4
Rated control supply voltage Us
• 50/60 Hz AC V 24 ... 240
• DC V 24 ... 240
Operating range
• 50/60 Hz AC 0.85 × Us min Us  1.1 x Us max
• DC 0.85 × Us min  Us  1.1 x Us max
Rated power
• 50/60 Hz AC W 0.5
• DC W 0.5
Mains buffering time ms 200
Sensor circuit
Thermistor motor protection (PTC thermistor sensor)
• Summation cold resistance k  1.5
• Response value k 3.4 ... 3.8
• Return value k 1.5 ... 1.65
Ground-fault detection The information refers to sinusoidal residual currents at 50/60 Hz.
• Tripping value I1)
- For 0.3 × Ie < Imotor < 2.0 × Ie > 0.3 x Ie

7
- For 2.0 × Ie < Imotor < 8.0 × Ie > 0.15 x Imotor
• Response time ttrip ms 500 ... 1 000
Analog output1)2)
Rated values
• Output signal mA 4 ... 20
• Measuring range 0 ... 1.25 x Ie
4 mA corresponds to 0 x Ie
16.8 mA corresponds to 1.0 x Ie
20 mA corresponds to 1.25 x Ie
• Load, max.  100
Conductor cross-sections for the auxiliary, control and
sensor circuits as well as the analog output
Connection type Screw terminals

Terminal screw M3, Pozidriv size 2


Operating devices mm 3.0 x 0.5
Prescribed tightening torque Nm 0.8 ... 1.2
Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 1 x (0.5 ... 4)3), 2 x (0.5 ... 2.5)3)
• Finely stranded without end sleeve mm2 --
• Finely stranded with end sleeve (DIN 46228) mm2 1 x (0.5 ... 2.5)3), 2 x (0.5 ... 1.5)3)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5


Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 --
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.25 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (24 ... 16)
1) 3)
For the 3RB22 and 3RB23 overload relays in combination with If two different conductor cross-sections are connected to one clamping
a corresponding function expansion module. point, both cross-sections must be in the range specified.
2) Analog input modules, e.g. SM 331, must be configured for four-wire
measuring transducers. In this case the analog input module must not
supply current to the analog output of the 3RB22 and 3RB23 relay.

Siemens IC 10 · 2023 7/123


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB22, 3RB23 for high-feature applications
Functions of the 3RB22 and 3RB23 evaluation modules in combination with the 3RB2985 function expansion modules
Evaluation modules With function Basic functions Inputs
expansion module
A1/A2 T1/T2 Y1/Y2
3RB2283-4AA1 -- Inverse-time delayed protection, Power supply Connection for Electrical
3RB2283-4AC1 temperature-dependent protection, 24 ... 240 V AC/DC PTC sensor Remote RESET
electrical Remote RESET,
3RB2383-4AA1 overload warning
3RB2383-4AC1 3RB2985-2CA1 Inverse-time delayed protection, Power supply Connection for Electrical
temperature-dependent protection, 24 ... 240 V AC/DC PTC sensor Remote RESET
internal ground-fault detection,
electrical Remote RESET,
overload warning
3RB2985-2CB1 Inverse-time delayed protection, Power supply Connection for Electrical
temperature-dependent protection, 24 ... 240 V AC/DC PTC sensor Remote RESET
internal ground-fault detection,
electrical Remote RESET,
ground-fault signal
3RB2985-2AA0 Inverse-time delayed protection, Power supply Connection for Electrical
temperature-dependent protection, 24 ... 240 V AC/DC PTC sensor Remote RESET
electrical Remote RESET,
overload warning, analog output
3RB2985-2AA1 Inverse-time delayed protection, Power supply Connection for Electrical
temperature-dependent protection, 24 ... 240 V AC/DC PTC sensor Remote RESET
internal ground-fault detection,
electrical Remote RESET,
overload warning, analog output
3RB2985-2AB1 Inverse-time delayed protection, Power supply Connection for Electrical
temperature-dependent protection, 24 ... 240 V AC/DC PTC sensor Remote RESET
internal ground-fault detection,
electrical Remote RESET,
7

ground-fault signal, analog output

Evaluation modules With function Outputs


expansion module
I (–)/I (+) 95/96 NC 97/98 NO 05/06 NC 07/08 NO
3RB2283-4AA1 -- No Disconnection Signal Overload warning Overload warning
3RB2283-4AC1 of the contactor "tripped"
(inverse-time delayed/
3RB2383-4AA1 temperature-dependent
3RB2383-4AC1 protection)
3RB2985-2CA1 No Disconnection Signal Overload warning Overload warning
of the contactor "tripped"
(inverse-time delayed/
temperature-dependent
protection + ground fault)
3RB2985-2CB1 No Disconnection Signal Disconnection of the Signal
of the contactor "tripped" contactor (ground "ground-fault
(inverse-time delayed/ fault) tripping"
temperature-dependent
protection)
3RB2985-2AA0 Analog signal Disconnection Signal Overload warning Overload warning
of the contactor "tripped"
(inverse-time delayed/
temperature-dependent
protection)
3RB2985-2AA1 Analog signal Disconnection Signal Overload warning Overload warning
of the contactor "tripped"
(inverse-time delayed/
temperature-dependent
protection + ground fault)
3RB2985-2AB1 Analog signal Disconnection Signal Disconnection of the Signal
of the contactor "tripped" contactor (ground "ground-fault
(inverse-time delayed/ fault) tripping"
temperature-dependent
protection)

7/124 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
IE3 ready IE4 ready IE3/IE4 ready 3RB22, 3RB23 for high-feature applications
3RB22 and 3RB23 electronic overload relays (evaluation modules) for full motor protection for stand-alone installation,
CLASS 5E, 10E, 20E and 30E (adjustable)
Type 3RB2283-4A.1, 3RB2383-4A.1
Features and technical specifications
Overload protection, phase failure protection and asymmetry protection ✓
Supplied from an external source ✓
24 ... 240 V AC/DC
Auxiliary contacts ✓
2 NO + 2 NC
Electrical Remote RESET integrated ✓
Four LEDs for operating and status displays ✓
TEST function and self-monitoring ✓
Internal ground-fault detection ✓
(with function expansion module)
Screw or spring-loaded terminals for auxiliary, control and sensor circuits ✓
Input for PTC sensor circuit ✓
Analog output ✓
(with function expansion module)
✓ Available

■ Selection and ordering data


PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41G

7
3RB2283-4AA1 3RB2283-4AC1
Size Version Screw terminals Spring-loaded
contactor terminals
Article No. Price Article No. Price
per PU per PU
Evaluation modules
S00 ... S12 Monostable 3RB2283-4AA1 3RB2283-4AC1
Bistable 3RB2383-4AA1 3RB2383-4AC1

Note: Current measuring modules and related connecting cables,


see page 7/137, general accessories, see page 7/138 onwards.
Overview of overload relays – matching contactors,
see page 7/81.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/125
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB22, 3RB23 for high-feature applications IE3 ready IE4 ready IE3/IE4 ready

Function expansion modules for 3RB22 and 3RB23 overload relays (evaluation modules)
Size Version For Article No. Price PU PS* PG
contactor overload per PU (UNIT,
relays SET, M)

Sizes S00 to S12


For plugging into evaluation module
(1 unit)
S00 ... S12 Analog Basic 1 modules1) 3RB22, 3RB2985-2AA0 1 1 unit 41F
Analog output 4 ... 20 mA DC, 3RB23
with overload warning
Analog Basic 1 GF modules1)2) 3RB22, 3RB2985-2AA1 1 1 unit 41F
Analog output 4 ... 20 mA DC, 3RB23
with internal ground-fault detection
and overload warning
3RB2985-2..1
Analog Basic 2 GF modules1)2) 3RB22, 3RB2985-2AB1 1 1 unit 41F
Analog output 4 ... 20 mA DC, 3RB23
with internal ground-fault detection and
ground-fault signaling
Basic 1 GF modules2) 3RB22, 3RB2985-2CA1 1 1 unit 41F
with internal ground-fault detection and 3RB23
overload warning
Basic 2 GF modules2) 3RB22, 3RB2985-2CB1 1 1 unit 41F
with internal ground-fault detection and 3RB23
ground-fault signaling
1)
The analog signal 4 to 20 mA DC can be used for operating rotary coil Note:
instruments or for feeding into analog inputs of programmable logic
controllers. Analog input modules, e.g. SM 331, must be configured for
2) four-wire measuring transducers. In this case the analog input
The following information on ground-fault protection refers to sinusoidal
7

residual currents at 50/60 Hz: module must not supply current to the analog output of the
- With a motor current of between 0.3 and 2 times the current setting Ie, the 3RB22/3RB23 relay.
unit will trip at a ground-fault current equal to 30% of the current setting.
- With a motor current of between 2 and 8 times the current setting Ie, the
unit will trip at a ground-fault current equal to 15% of the motor current.
- The response delay amounts to between 0.5 s and 1 s.

* You can order this quantity or a multiple thereof.


7/126 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB24 for IO-Link for high-feature applications

■ Overview
More information
Homepage, see www.siemens.com/sirius-control Application Manual for switching devices with IE3 and IE4 motors, see
Industry Mall, see www.siemens.com/product?3RB2 https://support.industry.siemens.com/cs/ww/en/view/94770820
Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/46165627
Certificates, see https://support.industry.siemens.com/cs/ww/en/ps/16281/cert

An overload, phase asymmetry or phase failure result in an


increase of the motor current beyond the set rated motor current.

NSB0_02180c
This current rise is detected by means of the current measuring
module (see page 7/137) and electronically evaluated by the
 evaluation module which is connected to it. The evaluation
 
electronics sends a signal to the auxiliary contacts. The auxiliary
contacts then switch off the load by means of a contactor.
 The break time depends on the ratio between the tripping

current and the current setting Ie and is stored in the form of
 a long-term stable tripping characteristic curve, see Equipment

 Manual. The "tripped" status is signaled by means of
a continuously illuminated red "OVERLOAD" LED and also
 
reported as a group fault via IO-Link.
The LED indicates imminent tripping of the relay due to overload,
 Plug-in point for operator panel: phase asymmetry or phase failure by flickering when the limit
enables connection of the 3RA6935-0A operator panel. current has been violated. This warning can also be reported to
 Motor current and trip class setting: the higher-level PLC via IO-Link at the 3RB24 overload relays.
Setting the device to the motor current and to the required trip

7
class dependent on the starting conditions is easy with the two In addition to the described inverse-time delayed protection of
rotary switches. loads against excessive temperature rises, the 3RB24 electronic
overload relays also allow direct temperature monitoring of the
 Connecting terminals (removable terminal block):
The generously sized terminals permit connection of two motor windings (full motor protection!) by connection with
conductors with different cross-sections for the auxiliary, control broken-wire interlock of a PTC sensor circuit. With this
and sensor circuits. Connection is possible with screw terminals temperature-dependent protection, the loads can be protected
and alternatively with spring-loaded terminals.
against overheating caused, for example, indirectly by reduced
 Test/RESET button: coolant flow and which cannot be detected by means of the
Enables testing of all important device components and functions,
plus resetting of the device after a trip when Manual RESET is current alone. In the event of overheating, the devices switch off
selected. the contactor, and thus the load, by means of the auxiliary
contacts. The "tripped" status is signaled by means of
 Selector switch for Manual/Automatic RESET:
With this switch you can choose between Manual and Automatic a continuously illuminated "THERMISTOR" LED and also reported
RESET. as a group fault via IO-Link.
 Red LED "OVERLOAD": To protect the loads against incomplete ground faults due to
A continuous red light signals an active overload trip; a flickering
led light signals an imminent trip (overload warning). damage to the insulation, humidity, condensation, etc., the
3RB24 electronic overload relays offer the possibility of internal
 Red LED "THERMISTOR": ground-fault detection (for details, see Equipment Manual,
A continuous red light signals an active thermistor trip.
not possible in conjunction with contactor assemblies for
 Red LED "GND FAULT": star-delta (wye-delta) starting). In the event of a ground fault,
A continuous red light signals an active ground-fault trip.
the 3RB24 relays trip instantaneously.
 Green LED "DEVICE/IO-Link:
A continuous green light signals that the device is working The "tripped" status is signaled by means of a flashing red
correctly, a green flickering light signals the communication "Ground Fault" LED and reported at the 3RB24 overload relay as
through IO-Link. a group fault via IO-Link.

SIRIUS 3RB24 evaluation module


The reset after overload, phase asymmetry, phase failure,
thermistor or ground-fault tripping is performed manually
The modular, IO-Link powered 3RB24 electronic overload relays by key on site, via IO-Link or by electrical Remote RESET
(with monostable auxiliary contacts) up to 630 A (up to 820 A or automatically after the cooling time (motor model) or for
possible with a series transformer) have been designed for thermistor protection after sufficient cooling. Trips in devices
inverse-time delayed protection of loads with normal and heavy initiated by function monitoring systems (broken wire or short-
starting against excessive temperature rises due to overload, circuit on the thermistor) can only be reset locally.
phase asymmetry or phase failure. These comprise an evaluation
unit, a current measuring module and a connecting cable. A motor current measured by the microprocessor can be output
in the form of an analog signal 4 to 20 mA DC for operating
The 3RB24 evaluation module also offers a motor starter rotary coil instruments or for feeding into analog inputs of
function: The contactors, which are connected via the auxiliary programmable logic controllers.
contacts, can also be actuated for operation via IO-Link. In this
way, direct, reversing and star-delta (wye-delta) starters up to
630 A (or 830 A) can be connected to the controller via the
IO-Link.

Siemens IC 10 · 2023 7/127


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB24 for IO-Link for high-feature applications
The current values can be transmitted to the higher-level Use in hazardous areas
controller via IO-Link.
The 3RB24 electronic overload relays for IO-Link with the 3RB29
The 3RB24 electronic overload relay for IO-Link is suitable for current measuring module are suitable for the overload
operation with frequency converters. protection of motors with the following types of protection:
The devices are manufactured in accordance with environ- • II (2) G[Ex e] [Ex d] [Ex px]
mental guidelines and contain environmentally friendly and • II (2) D[Ex t] [Ex p]
reusable materials. They comply with all important worldwide
standards and approvals. EC type-examination certificate for Group II, Category (2)
G/D exists. It has the number PTB 11 ATEX 3014.

Article number scheme


Product versions Article number
Electronic overload relays 3RB2 @ @ @ – @ @ @ @
Device type e.g. 4 = monostable device for high-feature applications, supplied @
from external source (24 V DC), for three-phase loads
Size, rated operational current e.g. 8 = irrespective of size and current @
and power
Version of the Automatic RESET, e.g. 3 = switchable between Manual/Automatic RESET, @
electrical Remote RESET with integral electrical Remote RESET
Trip class (CLASS) e.g. 4 = CLASS 5E, 10E, 20E, 30E (adjustable) @
Setting range of the overload release e.g. A = none specified @
Connection methods e.g. A = screw terminals for auxiliary, control and main circuits @
Installation type e.g. 1 = stand-alone installation @
Example 3RB2 4 8 3 – 4 A A 1
Note:
7

The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

7/128 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB24 for IO-Link for high-feature applications

■ Application
Industries Ambient conditions
The 3RB24 electronic overload relays are suitable for customers The devices are insensitive to external influences such as
from all industries who want to guarantee optimum current and shocks, corrosive ambient conditions, aging and temperature
temperature-dependent protection of their electrical loads (e.g. fluctuations.
motors) under normal and heavy starting conditions (CLASS 5E
to 30E), minimize project completion times, inventories and In the temperature range from -25 to +60 °C, the 3RB24
energy consumption, and optimize plant availability and electronic overload relays compensate the temperature in
maintenance management. accordance with IEC 60947-4-1.
Configuration notes for use of the devices below -25 °C or above
Application +60 °C on request.
The 3RB24 electronic overload relays have been designed for
the protection of three-phase asynchronous and single-phase Use of SIRIUS protection devices in conjunction with
AC motors. IE3 and IE4 motors

In addition to protection function, these devices can be used Note:


together with contactors as direct-on-line or reversing starters For the use of 3RB24 electronic overload relays in conjunction
(star-delta (wye-delta) start also possible), which are controlled with highly efficient IE3 and IE4 motors, please observe the
via IO-Link. This makes it possible to directly control drives via information on dimensioning and configuring, see Application
IO-Link from a higher-level controller or on site via the optional Manual.
handheld device and also, for example, to return current values
directly via IO-Link. For more information, see page 1/8.

If single-phase AC motors are to be protected by the 3RB24


electronic overload relays, the main conducting paths of the
current measuring modules must be series-connected
(circuit diagrams, see Equipment Manual).

7
■ Technical specifications
More information
Application Manual for switching devices with IE3 and IE4 motors, see Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/94770820 https://support.industry.siemens.com/cs/ww/en/view/46165627
Configuration Manual for load feeders, see Technical specifications, see
https://support.industry.siemens.com/cs/ww/en/view/39714188 https://support.industry.siemens.com/cs/ww/en/ps/16281/td

The following technical information is intended to provide an


initial overview of the various types of devices and functions.
Type – Overload relay: Evaluation modules 3RB2483-4A.1
Size contactor S00 ... S10/S12
H

Dimensions of evaluation modules mm 45 x 111 x 95


(W x H x D)
D

General data
Tripping in the event of Overload, phase failure and phase asymmetry (> 40% according to NEMA),
+ ground fault (connectable and disconnectable) and activation of the thermistor
motor protection (with closed PTC sensor circuit)
Trip class according to IEC 60947-4-1 CLASS 5E, 10E, 20E and 30E adjustable
Phase failure sensitivity Yes
Overload warning Yes, from 1.125 × Ie for symmetrical loads
and from 0.85 × Ie for asymmetrical loads
Reset and recovery
• Reset options after tripping Manual and Automatic RESET, electrical Remote RESET or via IO-Link
• Recovery time
- For Automatic RESET min. - For tripping due to overcurrent: 3 (stored permanently)
- For tripping by thermistor: time until the motor temperature has fallen 5 K
below the response temperature
- For tripping due to a ground fault: no Automatic RESET
- For Manual RESET min. - For tripping due to overcurrent: 3 (stored permanently)
- For tripping by thermistor: time until the motor temperature has fallen 5 K
below the response temperature
- For tripping due to a ground fault: immediately
- For Remote RESET min. - For tripping due to overcurrent: 3 (stored permanently)
- For tripping by thermistor: time until the motor temperature has fallen 5 K
below the response temperature
- For tripping due to a ground fault: immediately

Siemens IC 10 · 2023 7/129


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB24 for IO-Link for high-feature applications

Type – Overload relay: Evaluation modules 3RB2483-4A.1


Size contactor S00 ... S10/S12

H
Dimensions of evaluation modules mm 45 x 111 x 95
(W x H x D)

D
W

General data (continued)


Features
• Display of operating state on device Yes, with four LEDs:
- Green "DEVICE/IO-Link" LED
- Red LED "Ground Fault"
- Red LED "Thermistor"
- Red LED "Overload"
• TEST function Yes, test of LEDs, electronics, auxiliary contacts and wiring of control circuit by
pressing the TEST/RESET button/self-monitoring
• RESET button Yes, with the TEST/RESET button
• STOP button No
Protection and operation of explosion-proof motors
Certificate of suitability/explosion protection type according to PTB 11 ATEX 3014
ATEX Directive 2014/34/EU II (2) G[Ex e] [Ex d] [Ex px]
II (2) D[Ex t] [Ex p]
See https://support.industry.siemens.com/cs/ww/en/view/60524083
Ambient temperatures
• Storage/transport °C -40 ... +80
• Operation °C -25 ... +60
• Temperature compensation °C +60
• Permissible rated current
7

- Temperature inside control cabinet 60 °C % 100


- Temperature inside control cabinet 70 °C % On request
Degree of protection IP on the front according to IEC 60529 IP20
Touch protection on the front according to IEC 60529 Finger-safe for vertical touching from the front
Shock resistance with sine according to IEC 60068-2-27 g/ms 15/11
Electromagnetic compatibility (EMC) – Interference immunity
• Conductor-related interference
- Burst according to IEC 61000-4-4 kV 2 (power ports), 1 (signal port)
(corresponds to degree of severity 3)
- Surge according to IEC 61000-4-5 kV 2 (line to earth), 1 (line to line)
(corresponds to degree of severity 3)
• Electrostatic discharge according to IEC 61000-4-2 kV 8 (air discharge), 6 (contact discharge)
(corresponds to degree of severity 3)
• Field-related interference according to IEC 61000-4-3 V/m 10
(corresponds to degree of severity 3)
Electromagnetic compatibility (EMC) – Emitted interference Degree of severity A according to EN 55011 (CISPR 11) and EN 55022 (CISPR 22)
Installation altitude above sea level m Up to 2 000
Mounting position Any
Type of mounting
• Evaluation modules Stand-alone installation
• Current measuring modules Size S00 to S3: Stand-alone installation,
S6 and S10/S12: Stand-alone installation or mounting on contactors

7/130 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB24 for IO-Link for high-feature applications

Type – Overload relay: Evaluation modules 3RB2483-4A.1


Size contactor S00 ... S10/S12
Auxiliary circuit
Number of auxiliary switches 1 CO contact, 1 NO contact connected in series internally
Auxiliary contacts – Assignment • 1 CO contact for selecting the contactor (for reversing starter function),
actuated by the control system
• 1 NO contact for normal switching duty, actuated by the control system
(opens automatically when tripping occurs)
Rated insulation voltage Ui (pollution degree 3) V 300
Rated impulse withstand voltage Uimp kV 4
Auxiliary contacts – Contact rating
• NC, NO contact with alternating current AC-14/AC-15,
rated operational current Ie at Ue
- 24 V A 6
- 120 V A 6
- 125 V A 6
- 250 V A 3
• NC, NO contacts with direct current DC-13,
rated operational current Ie at Ue
- 24 V A 2
- 60 V A 0.55
- 110 V A 0.3
- 125 V A 0.3
- 250 V A 0.2
• Conventional thermal current Ith A 5
• Contact reliability Yes
(suitability for PLC control; 17 V, 5 mA)
Short-circuit protection

7
• With fuse, operational class gG A 6
• With miniature circuit breaker, C characteristic A 1.6
Protective separation between auxiliary conducting paths V 300
according to IEC 60947-1
CSA, UL and UR rated data
Auxiliary circuit – Switching capacity B300, R300
Conductor cross-sections of the auxiliary circuit
Connection type Screw terminals

Terminal screw M3, Pozidriv size 2


Operating devices mm 3.0 x 0.5
Prescribed tightening torque Nm 0.8 ... 1.2
Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 1 x (0.5 ... 4)1), 2 x (0.5 ... 2.5)1)
• Finely stranded without end sleeve mm2 --
• Finely stranded with end sleeve (DIN 46228) mm2 1 x (0.5 ... 2.5)1), 2 x (0.5 ... 1.5)1)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5


Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 –
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.25 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (24 ... 16)
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must be in the range specified.

Siemens IC 10 · 2023 7/131


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
3RB24 for IO-Link for high-feature applications

Type – Overload relay: Evaluation modules 3RB2483-4A.1


Size contactor S00 ... S10/S12
Control circuit
Rated insulation voltage Ui V 300
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 4
Rated control supply voltage Us1)
• DC V 24 via IO-Link
Operating range
• DC 0.85 x Us min  Us  1.1 x Us max
Rated power
• DC W 0.5
Mains buffering time ms 200
Sensor circuit
Thermistor motor protection (PTC thermistor sensor)
• Summation cold resistance k  1.5
• Response value k 3.4 ... 3.8
• Return value k 1.5 ... 1.65
Ground-fault detection The information refers to sinusoidal residual currents at 50/60 Hz.
• Tripping value I
- For 0.3 × Ie < Imotor < 2.0 × Ie > 0.3 x Ie
- For 2.0 × Ie < Imotor < 8.0 × Ie > 0.15 x Imotor
• Response time ttrip ms 500 ... 1 000
Analog output1)
7

Rated values
• Output signal mA 4 ... 20
• Measuring range 0 ... 1.25 x Ie
4 mA corresponds to 0 x Ie
16.8 mA corresponds to 1.0 x Ie
20 mA corresponds to 1.25 x Ie
• Load, max.  100
Conductor cross-sections for the control and sensor circuit
as well as the analog output
Connection type Screw terminals

Terminal screw M3, Pozidriv size 2


Operating devices mm 3.0 x 0.5
Prescribed tightening torque Nm 0.8 ... 1.2
Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid mm2 1 x (0.5 ... 4)2), 2 x (0.5 ... 2.5)2)
• Finely stranded without end sleeve mm2 --
• Finely stranded with end sleeve (DIN 46228) mm2 1 x (0.5 ... 2.5)2), 2 x (0.5 ... 1.5)2)
• Stranded mm2 --
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5


Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid mm2 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 --
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.25 ... 1.5)
• Stranded mm2 2 x (0.25 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (24 ... 16)
1) Analog input modules, e.g. SM 331, must be configured for four-wire 2) If two different conductor cross-sections are connected to one clamping
measuring transducers. The analog input module may not supply current point, both cross-sections must be in the range specified.
to the analog output of the 3RB24 overload relay.

7/132 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
IE3 ready IE4 ready IE3/IE4 ready 3RB24 for IO-Link for high-feature applications
3RB24 electronic overload relays (evaluation modules) for full motor protection for stand-alone installation,
CLASS 5E, 10E, 20E and 30E (adjustable)
Type 3RB2483-4A.1
Features and technical specifications
Overload protection, phase failure protection and asymmetry protection ✓
Supplied from an external source ✓
24 V DC via IO-Link
Direct-on-line or reversing starters (star-delta (wye-delta) starting also possible) ✓
controllable via IO-Link
Auxiliary contacts ✓
1 CO and 1 NO in series
Manual and Automatic RESET ✓
Remote RESET ✓
(electrically or via IO-Link)
Four LEDs for operating and status displays ✓
TEST function and self-monitoring ✓
Internal ground-fault detection ✓
Screw or spring-loaded terminals for auxiliary, control and sensor circuits ✓
Input for thermistor (PTC) sensor circuit ✓
Analog output ✓
IO-Link-specific functions
• Connection of direct-on-line, reversing and star-delta (wye-delta) starters to the controller via IO-Link ✓
• On-site controlling of the starter using the handheld device ✓
• Accessing process data (e.g. current values in all three phases) via IO-Link ✓
• Accessing parameterization and diagnostics data (e.g. tripped signals) via IO-Link ✓

7
✓ Available

■ Selection and ordering data


PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41G

3RB2483-4AA1 3RB2483-4AC1
Size Version Screw terminals Spring-loaded
contactor terminals
Article No. Price Article No. Price
per PU per PU
Evaluation modules
S00 ... S12 Monostable 3RB2483-4AA1 3RB2483-4AC1

Notes: Current measuring modules and related connecting cables,


• Overview of overload relays – matching contactors, see page 7/137. More accessories, see page 7/138 onwards.
see page 7/81.
• Analog input modules, e.g. SM 331, must be configured for
four-wire measuring transducers. The analog input module may
not supply current to the analog output of the 3RB24 relay.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/133
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
Current measuring modules for 3RB22, 3RB23 and 3RB24

■ Overview
More information
Homepage, see www.siemens.com/sirius-control Application Manual for switching devices with IE3 and IE4 motors, see
Industry Mall, see www.siemens.com/product?3RB2 https://support.industry.siemens.com/cs/ww/en/view/94770820
Other manuals, see
https://support.industry.siemens.com/cs/ww/en/ps/16282/man

The current measuring modules are designed as system


components for connecting to 3RB22 to 3RB24 evaluation units.
Using these evaluation units the motor current is measured and
the measured value sent to the evaluation unit for evaluation.
The current measuring modules in sizes up to S3 are equipped
with straight-through transformers and can be snap-fitted under
the evaluation units. The larger evaluation units are installed
directly on the contactor or as stand-alone units.

SIRIUS 3RB2906 current measuring module


7

■ Application
Use of SIRIUS protection devices in conjunction with
IE3 and IE4 motors
Note:
For the use of current measuring modules for 3RB22, 3RB23,
3RB24 in conjunction with highly efficient IE3 and IE4 motors,
please observe the information on dimensioning and
configuration, see Application Manual.
For more information, see page 1/8.

7/134 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
Current measuring modules for 3RB22, 3RB23 and 3RB24

■ Technical specifications
More information
Manuals, see Technical specifications, see
https://support.industry.siemens.com/cs/ww/en/ps/16282/man https://support.industry.siemens.com/cs/ww/en/ps/16282/td

The following technical information is intended to provide an


initial overview of the various types of devices and functions.

Type – Overload relays: Current measuring 3RB2906 3RB2956 3RB2966


modules

H
Size contactor S00/S0 S2/S3 S6 S10/S12
Dimensions of current measuring modules mm 45 x 84 x 45 55 x 94 x 72 120 x 119 x 145 145 x 147 x 148

D
W
(W x H x D)
Main circuit
Rated insulation voltage Ui V 690 1 000
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 6 8
Rated operational voltage Ue V 690 1 000
Type of current
• Direct current No
• Alternating current Yes, 50/60 Hz 5%
Current setting A 0.3 ... 3; 10 ... 100 20 ... 200 63 ... 630
2.4 ... 25
Power loss per unit (max.) W 0.5
Short-circuit protection
• With fuse without contactor See "Selection and ordering data", page 7/137

7
• With fuse and contactor See Configuration Manual
Degree of protection IP on the front according to IEC 60529
• Screw terminals/busbar connections IP20 IP00 (IP20 with box terminal/cover)
• Straight-through transformers IP20 IP20 --
Touch protection on the front according to IEC 60529
• Screw terminals/busbar connections Finger-safe for vertical Finger-safe for vertical touching from the front
touching from the front (with box terminals/cover)
• Straight-through transformers Finger-safe for vertical Finger-safe for vertical --
touching from the front touching from the front
Protective separation between main and auxiliary conducting paths
According to IEC 60947-1 (pollution degree 2)
• For systems with grounded neutral point V 690
• For systems with ungrounded neutral point V 600

Siemens IC 10 · 2023 7/135


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
Current measuring modules for 3RB22, 3RB23 and 3RB24

Type – Overload relays: Current measuring 3RB2906 3RB2956 3RB2966


modules

H
Size contactor S00/S0 S2/S3 S6 S10/S12
Dimensions of current measuring modules mm 45 x 84 x 45 55 x 94 x 72 120 x 119 x 145 145 x 147 x 148

D
W
(W x H x D)
Conductor cross-sections of main circuit
Connection type Screw terminals with box terminal

Terminal screw mm -- 4 mm Allen screw 5 mm Allen screw


Operating devices mm -- 4 mm Allen screw 5 mm Allen screw
Prescribed tightening torque Nm -- 10 ... 12 20 ... 22
Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid or stranded mm2 -- With 3RT1955-4G 2 x (70 ... 240),
box terminal: Front clamping
2 x (max. 70), point only:
1 x (16 ... 70) 1 x (95 ... 300)
With 3RT1956-4G Rear clamping
box terminal: point only:
2 x (max. 120), 1 x (120 ... 240)
1 x (16 ... 120)
• Finely stranded without end sleeve mm2 -- With 3RT1955-4G 2 x (50 ... 185),
box terminal: Front clamping
2 x (1 x max. 50, point only:
1 x max. 70), 1 x (70 ... 240)
1 x (10 ... 70)
With 3RT1956-4G Rear clamping
box terminal: point only:
2 x (1 x max. 95, 1 x (120 ... 185)
7

1 x max. 120),
1 x (10 ... 120)
• Finely stranded with end sleeve (DIN 46228) mm2 -- With 3RT1955-4G 2 x (50 ... 185),
box terminal: Front clamping
2 x (1 x max. 50, point only:
1 x max. 70), 1 x (70 ... 240)
1 x (10 ... 70)
With 3RT1956-4G Rear clamping
box terminal: point only:
2 x (1 x max. 95, 1 x (120 ... 185)
1 x max. 120),
1 x (10 ... 120)
• AWG cables AWG -- With 3RT1955-4G 2 x (2/0 ... 500 kcmil),
box terminal: Front clamping
2 x (max. 1/0), point only:
1 x (6 ... 2/0) 1 x (3/0 ... 600 kcmil)
With 3RT1956-4G Rear clamping
box terminal: point only:
2 x (max. 3/0), 1x
1 x (6 ... 250 kcmil) (250 kcmil ... 500 kcmil)
• Ribbon cables (number x width x thickness) mm -- With 3RT1955-4G 2 x (20 x 24 x 0.5),
box terminal: 1 x (6 x 9 x 0.8 ...
2 x (6 x 15.5 x 0.8), 20 x 24 x 0.5)
1 x (3 x 9 x 0.8 ...
6 x 15.5 x 0.8)
With 3RT1956-4G
box terminal:
2 x (10 x 15.5 x 0.8),
1 x (3 x 9 x 0.8 ...
10 x 15.5 x 0.8)
Connection type Busbar connections

Terminal screw -- M8 x 25 M10 x 30


Prescribed tightening torque Nm -- 10 ... 14 14 ... 24
Conductor cross-sections (min./max.),
one or two conductors can be connected
• Solid with cable lug mm2 -- 16 ... 951) 50 ... 2402)
• Stranded with cable lug mm2 -- 25 ... 1201) 70 ... 2402)
• AWG cables, solid or stranded, with cable lug AWG -- 4 ... 250 kcmil 2/0 ... 500 kcmil
• With connecting bars (max. width) mm -- 17 25
Connection type Straight-through transformers

Diameter of opening mm 7.5 14 25 --


1) When connecting cable lugs according to DIN 46235 with conductor 2) When connecting cable lugs according to DIN 46234 for conductor cross-
cross-sections from 95 mm2, the 3RT1956-4EA1 terminal cover must be sections from 240 mm2, as well as DIN 46235 for cable cross-sections
used to ensure phase clearance, see page 7/138. from 185 mm2, the 3RT1956-4EA1 terminal cover must be used to ensure
phase clearance, see page 7/138.

7/136 Siemens IC 10 · 2023


© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
IE3 ready IE4 ready IE3/IE4 ready Current measuring modules for 3RB22, 3RB23 and 3RB24

■ Selection and ordering data


Current measuring modules (essential accessories)

3RB2906-2BG1 3RB2906-2DG1 3RB2906-2JG1 3RB2956-2TG2 3RB2966-2WH2


Size Current setting value Short-circuit protection For Article No. Price PU PS* PG
contactor of the inverse-time with fuse, type of overload per PU (UNIT,
delayed overload coordination "2", relays SET, M)
1)
release operational class gG
A A
Sizes S00/S0
Devices with straight-through transformer
for stand-alone installation
S00/S0 0.3 … 3 20 3RB22 to 3RB2906-2BG1 1 1 unit 41G
2.4 … 25 63 3RB24 3RB2906-2DG1 1 1 unit 41G
Sizes S2/S3
Devices with straight-through transformer
for stand-alone installation

7
S2/S3 10 … 100 315 3RB22 to 3RB2906-2JG1 1 1 unit 41G
3RB24
Size S6
Devices with busbar connection,
for mounting on contactor and stand-alone installation
(an appropriate connection kit with screws,
spring washers and nuts is enclosed)
S6 20 … 200 315 3RB22 to 3RB2956-2TH2 1 1 unit 41G
3RB24
Devices with straight-through transformer,
for mounting on contactor and stand-alone installation
For mounting on 20 … 200 315 3RB22 to 3RB2956-2TG2 1 1 unit 41G
S6 contactors with 3RB24
box terminals
Sizes S10/S122)
Devices with busbar connection,
for mounting on contactor and stand-alone installation
(an appropriate connection kit with screws,
spring washers and nuts is enclosed)
S10/S12 63 … 630 800 3RB22 to 3RB2966-2WH2 1 1 unit 41G
and 3RB24
size 14 (3TF68/3TF69)2)
1) Maximum protection by fuse only for overload relays, type of Note:
coordination "2". For fuse values in connection with contactors,
see Configuration Manual. The connecting cable between the current measuring module
2) and the evaluation module is not included in the scope of
For 3TF68/3TF69 contactors, direct mounting is not possible.
supply; please order separately (see "Accessories").

■ Accessories
Size Version For Article No. Price PU PS* PG
contactor overload per PU (UNIT,
relays SET, M)

Connecting cables (essential accessories)


For connection between evaluation module
and current measuring module
S00 ... S3 • Length 0.1 m 3RB22 to 3RB2987-2B 1 1 unit 41F
(only for mounting of the evaluation 3RB24
module directly on the current measuring
module)
3RB2987-2D S00 ... S12 • Length 0.5 m 3RB22 to 3RB2987-2D 1 1 unit 41F
3RB24

Additional general accessories, see page 7/138.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/137
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
Accessories for 3RB22, 3RB23, 3RB24

■ Overview
More information
Homepage, see www.siemens.com/sirius-control Manuals, see
Industry Mall, see www.siemens.com/product?3RB2 https://support.industry.siemens.com/cs/ww/en/ps/16283/man

The following optional accessories are available for the 3RB22 to • Terminal covers for the 3RB29 current measuring modules
3RB24 electronic overload relays: size S6 and S10/S12
• Operator panel for the 3RB24 evaluation modules • Box terminal blocks for the 3RB29 current measuring modules
• Sealable cover for the 3RB22 to 3RB24 evaluation modules size S6 and S10/S12
• Push-in lugs for screw fixing for 3RB22 to 3RB24 evaluation
modules and 3RB2906 current measuring modules

■ Selection and ordering data


Accessories for 3RB24 overload relays
Version For Article No. Price PU PS* PG
overload per PU (UNIT,
relays SET, M)

Operator panels for evaluation modules


Operator panels (set) 3RB24 3RA6935-0A 1 1 unit 42F
One set comprises:
• 1 x operator panel
• 1 x 3RA6936-0A enabling module
• 1 x 3RA6936-0B interface cover
• 1 x fixing terminal
7

3RA6935-0A
Note:
The connecting cable between the evaluation
module and the operator panel is not included
in the scope of supply; please order
separately.
Connecting cable 3RB24 3UF7933-0BA00-0 1 1 unit 42J
Length 2.5 m (round),
for connecting the evaluation module to the
operator panel
Enabling modules (spare part) 3RB24 3RA6936-0A 1 1 unit 42F
Interface covers 3RB24 3RA6936-0B 1 5 units 42F

General accessories
Version Size For Article No. Price PU PS* PG
overload per PU (UNIT,
relays SET, M)

Sealable covers for evaluation modules


For covering the setting knobs -- 3RB22 to 3RB2984-2 1 10 units 41F
3RB24

3RB2984-2
Terminal covers for current measuring modules
Covers for cable lugs and
busbar connections
• Length 100 mm S6 3RB2956 3RT1956-4EA1 1 1 unit 41B
• Length 120 mm S10/S12 3RB2966 3RT1966-4EA1 1 1 unit 41B
Covers for box terminals
• Length 25 mm S6 3RB2956 3RT1956-4EA2 1 1 unit 41B
3RT1956-4EA1 • Length 30 mm S10/S12 3RB2966 3RT1966-4EA2 1 1 unit 41B
Covers for screw terminals S6 3RB2956 3RT1956-4EA3 1 1 unit 41B
Between contactor and overload S10/S12 3RB2966 3RT1966-4EA3 1 1 unit 41B
relay, without box terminals
3RT1956-4EA2 (1 unit required per combination)

Box terminal blocks for current measuring modules


For round and ribbon cables
• Up to 70 mm2 S61) 3RB2956 3RT1955-4G 1 1 unit 41B
• Up to 120 mm2 S6 3RB2956 3RT1956-4G 1 1 unit 41B
• Up to 240 mm2 S10/S12 3RB2966 3RT1966-4G 1 1 unit 41B
3RT1955-4G
1) In the scope of supply for 3RT1054-1 contactors (55 kW).

* You can order this quantity or a multiple thereof.


7/138 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Protection equipment
Overload relays
SIRIUS 3RB2 electronic overload relays
Accessories for 3RB22, 3RB23, 3RB24

Version Size For Article No. Price PU PS* PG


overload per PU (UNIT,
relays SET, M)

Push-in lugs for evaluation modules and current measuring modules


For screw fixing the evaluation modules -- 3RB22 to 3RP1903 1 10 units 41H
3RB24
3RP1903
For screw fixing the current S00 ... S3 3RB2906 3RB1900-0B 100 10 units 41F
measuring modules
(2 units per module)

3RB1900-0B

Version Size Color For Article No. Price PU PS* PG


overload per PU (UNIT,
relays SET, M)

Tools for opening spring-loaded terminals


Spring-loaded
terminals

Screwdrivers Length approx. Titanium Main and 3RA2908-1A 1 1 unit 41B


For all SIRIUS 200 mm, gray/ auxiliary
3RA2908-1A
devices with 3.0 mm x 0.5 mm black, circuit

7
spring-loaded partially connection:
terminals insulated 3RB2
Blank labels
Unit labeling 20 mm x 7 mm Titanium 3RB2 3RT2900-1SB20 100 340 41B
plates1) gray units
For SIRIUS devices
Adhesive labels 19 mm x 6 mm Titanium 3RB2 3RT2900-1SB60 100 3 060 41B
For SIRIUS devices gray units
IC01_00181

3RT2900-1SB20
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 7/139
© Siemens 2023

Protection equipment

Notes
7

7/140 Siemens IC 10 · 2023


8
© Siemens 2023

Load feeders and motor starters for use in the control cabinet

Price groups
PG 14O, 255, 41B, 41D, 41E, 41L,
42C, 42D, 42F, 42G

8/2 Introduction

SIRIUS 3RA2 load feeders


8/5 General data
3RA21 direct-on-line starters
8/22 - for DIN-rail mounting or screw fixing
8/30 - for 60 mm busbars
3RA22 reversing starters
8/34 - for DIN-rail mounting or screw fixing
8/40 - for 60 mm busbars
8/45 Accessories
8/56 3RV29 infeed system for load feeders

SIRIUS 3RA6 compact starters


8/57 General data
3RA61, 3RA62 compact starters
8/65 - 3RA61 direct-on-line starters
8/66 - 3RA62 reversing starters
3RA64, 3RA65 compact starters
for IO-Link
8/67 - 3RA64 direct-on-line starters
8/68 - 3RA65 reversing starters
8/69 Accessories

8
8/74 Add-on modules for AS-Interface
8/76 Infeed system for 3RA6

8/83 SIRIUS 3RM1 motor starters

8/94 ET 200SP motor starters

Siemens IC 10 · 2023
© Siemens 2023

Load feeders and motor starters for use in the control cabinet

Introduction

■ Overview
Central and compact starter solutions
Our range offers you many different possibilities for simple with each other, have a very compact design and are particularly
and practical starter solutions in the control cabinet. Features easy and quick to install and wire up.
common to all our load feeders, compact starters and motor
starters: Like all SIRIUS devices they are optimally coordinated In addition there is a seamless range of SIRIUS 3RW soft starters
available for soft starting in the control cabinet (see page 6/2).

SIRIUS pre-assembled combinations 1 200

Performance (kW/400 V)
SIRIUS tested combinations

SINAMICS G120
frequency converter
SINAMICS V20
frequency converter
625
Functionality

SIRIUS soft starter

ET 200SP motor starter


125
SIRIUS SIRIUS star-delta

IC01_00738a
G120C
(wye-delta) starter

G120X
direct-on-line
25

G120
SIRIUS 3RM1 and reversing
motor starter starter
5
Requirement Fixed Speed Variable Speed

Central and compact starter solutions


8

Decision support for motor start – Starting and operating


three-phase asynchronous motors efficiently

Decision support tool for motor start


This tool guides you to the optimum individual drive solution
via a short query about the application.
Based on this solution approach, you will then be directed to
the right product configurator for selecting the appropriate
products, see
www.siemens.com/motorstart-guide.

8/2 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

Introduction

3RA2110 3RA2110 3RA2210 3RA2210 3RA2130 3RA61 3RA62 3RA68


3RA2150
Type Page
SIRIUS 3RA2 load feeders
• The 3RA2 fuseless load feeders consist of the 3RV2 motor starter protector and
the 3RT2 contactor.
The motor starter protector and contactor are prewired and mechanically and
electrically connected in prefabricated assembly kits (link modules, wiring kits
and DIN-rail or busbar adapters)
• 4 sizes (S00, S0, S2, S3)
• Can be supplied for direct-on-line starting or reversing operation as
- a complete unit or
- single devices for self-assembly
• Can be supplied with screw or spring-loaded terminals
3RA21 direct-on-line starters • Rated control supply voltage 50/60 Hz 230 V AC and 24 V DC 3RA21 8/22
for DIN-rail mounting or screw fixing
3RA21 direct-on-line starters • Rated control supply voltage 50/60 Hz 230 V AC and 24 V DC 3RA21 8/30
for 60 mm busbars
3RA22 reversing starters • Rated control supply voltage 50/60 Hz 230 V AC and 24 V DC 3RA22 8/34
for DIN-rail mounting or screw fixing
3RA22 reversing starters • Rated control supply voltage 50/60 Hz 230 V AC and 24 V DC 3RA22 8/40

8
for 60 mm busbars
Accessories for 3RA2 direct-on-line and 8/45
reversing starters
Infeed system • The infeed system is a convenient means of energy supply and distribution 3RV29 7/67,
for a group of several motor starter protectors or complete load feeders with 8/56
screw or spring-loaded terminals up to size S0.
SIRIUS 3RA6 compact starters
• Integrated functionality of a motor starter protector, contactor and electronic
overload relay and various functions of optional mountable accessories
• Can be used for direct starting of standard three-phase motors up to 32 A
3RA61 direct-on-line starters • Up to 15 kW/400 V, weld-free, wide setting range, removable terminals 3RA61 8/65
3RA62 reversing starters • Up to 15 kW/400 V, weld-free, wide setting range, removable terminals 3RA62 8/66
3RA64 direct-on-line starters for IO-Link • Up to 15 kW/400 V, weld-free, wide setting range, removable terminals 3RA64 8/67
3RA65 reversing starters for IO-Link • Up to 15 kW/400 V, weld-free, wide setting range, removable terminals 3RA65 8/68
Accessories for 3RA6 direct-on-line and 3RA69 8/69
reversing starters
Add-on modules for AS-Interface 3RA69 8/74
Infeed system for 3RA6 • Modular expandability, up to 100 A, terminals up to 70 mm2 3RA68 8/76
• 3-phase infeeds and expansion modules 8/79
• Expansion modules 8/80
• Accessories for infeed systems for 3RA6 8/81

Siemens IC 10 · 2023 8/3


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

Introduction

3RM12 3RM13 3RK1308 3RK1308 3RK1908-0 3RK1908-1A


Type Page
SIRIUS 3RM1 motor starters
• For switching three-phase motors up to 3 kW (at 400 V) and resistive loads
up to 10 A at AC voltages up to 500 V under normal operating conditions
• Space-saving design (width 22.5 mm)
3RM10 direct-on-line starters • Direct-on-line starting with electronic overload protection 3RM10 8/90
3RM12 reversing starters • Reversing functionality with electronic overload protection 3RM12 8/90
3RM11 Failsafe direct-on-line starters • As 3RM10 plus safety-related shutdown 3RM11 8/90
3RM13 Failsafe reversing starters • As 3RM12 plus safety-related shutdown 3RM13 8/90
Accessories for 3RM1 motor starters • 3RM19 3-phase infeed system for the main circuit 3RM19 8/91
• Fuse modules for the use of 3RM1 motor starters on 3RM19 8/88
8US busbar systems and mounting rails
• Adapters 8US1 8/91
• Cover profiles 8US1922 8/92
• Device connectors for the control circuit 3ZY1212 8/92
• Spare terminals for main and control circuits 3ZY11 8/93
8

• Push-in lugs for wall mounting, integrated sealable cover, coding pins 3ZY1 8/93
ET 200SP motor starters
• In hybrid technology in the SIMATIC ET 200SP I/O system
• For the switching and protection of three-phase asynchronous motors,
1-phase AC motors and 1-phase asynchronous motors up to 5.5 kW
(at 400 V)
3RK1308 direct-on-line starters • Direct-on-line starting with electronic overload protection 3RK1308-0A.0 8/100
3RK1308 reversing starters • Reversing functionality with electronic overload protection 3RK1308-0B.0 8/100
3RK1308 fail-safe direct-on-line starters • Direct-on-line starting with electronic overload protection 3RK1308-0C.0 8/100
3RK1308 fail-safe reversing starters • Reversing functionality with electronic overload protection 3RK1308-0D.0 8/100
BaseUnits • Mounting components for infeed and for integration into the 3RK1908-0AP00 8/101
ET 200SP I/O system
3DI/LC control module • Module with three digital inputs for the use of additional functions such 3RK1908-1AA00 8/101
as "Quick stop", and for manual-local operation
Accessories • Cover for BaseUnit and infeed bus, additional mechanical mounting unit, fan 3RK19, 3RW49 8/102

8/4 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data

■ Overview
3RA2 load feeders

More information

Homepage, see www.siemens.com/sirius-control


Industry Mall, see www.siemens.com/product?3RA2
Online configurator, see www.siemens.com/sirius/configurators
TIA Selection Tool Cloud (TST Cloud), see
www.siemens.com/tstcloud/?node=LoadFeeder
Decision support for motor start – Starting and operating three-phase
asynchronous motors efficiently, see www.siemens.com/motorstart-guide

Operating conditions
3RA2 load feeders are climate-proof. They are intended for
use in enclosed rooms in which no severe operating conditions
(such as dust, caustic vapors, hazardous gases) prevail.
Suitable covers must be provided for installation in dusty
and damp locations.
Behavior in the event of short circuit
3RA22 reversing starters for DIN-rail mounting or screw fixing with screw EN 60947-4-1 (VDE 0660 Part 102) and IEC 60947-4-1 make
terminals a distinction between two different types of coordination,
which are referred to as type of coordination "1" and type of
The 3RA2 fuseless load feeders consist of the 3RV2 motor coordination "2". Any short circuits that occur are cleared safely
starter protector and the 3RT2 electromechanical contactor. by both types of coordination. The only differences concern the
The devices are electrically and mechanically connected using extent of the damage caused to the device by a short circuit.
prefabricated assembly kits (link modules, wiring kits and
DIN-rail or busbar adapters). ToC Type of coordination "1"
1
Around 500 preassembled 3RA2 combinations can be ordered The load feeder may be non-operational after a short
for direct-on-line and reversing starting of standard three-phase circuit has been cleared. Damage to the contactor or
to the overload release is permissible.

8
motors up to 65 A (approx. 37 kW/400 V). Prefabricated
assembly kits are available as accessories for the power
spectrum up to 45 kW. The desired fuseless load feeder can ToC Type of coordination "2"
2
thus be assembled quickly and economically by the customer. There must be no damage to the overload release
A time saving is also achieved in connection with switchgear or to any other components after a short circuit has
acceptances, as – unlike with conventional wiring systems – been cleared. The load feeder can resume operation
there is no need to rectify possible wiring errors. without needing to be renewed. At most, welding of
the contactor contacts is permissible if they can
In the 3RA2 load feeder, the 3RV2 motor starter protector be disconnected easily without any significant
is responsible for overload and short-circuit protection. deformation.
Back-up protective devices, such as melting fuses or limiters,
are superfluous here, as the motor starter protector is The types of coordination are indicated in
short-circuit proof up to 150 kA at 400 V. the corresponding tables by the symbols
The 3RT2 contactor is particularly suitable for extremely shown on orange backgrounds.
complex switching tasks requiring the greatest endurance.
Voltage specifications
The 3RA2 load feeders are available with setting ranges from
0.14 to 65 A in sizes S00, S0 and S2. Load feeders in size S3 up The specifications for 3-phase systems according to
to 100 A are available for customer assembly. IEC 60947-4-1 apply for the following line system configurations:
.

Size Width Max. rated current For three- Voltage Ue Line system configurations
Direct-on-line starters/ In max phase motors Three-phase Three-phase
reversing starters up to four-wire systems three-wire systems
mm A kW
S00 45/90 16 7.5
S0 45/90 32 15
IC01_00703

IC01_00709

S2 55/120 65 37
S3 70/150 100 45

The size of the 3RA2 load feeders is based on the size of the V V V
contactor: 230 -- 230
400 230/400 400
Size 3RA2 S00 S0 S2 S3
440 260/440 440
Size of 3RV2 motor starter S00 S001), S2 S3 500 -- 500
protector S0
690 400/690 690 (only from size S3)
Size of 3RT2 contactor S00 S0 S2 S3
-- Not specified
1)
The combination of an S00 motor starter protector with an S0 contactor is
possible only for screw terminal versions.

Siemens IC 10 · 2023 8/5


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Tripping times In particular, certain accessories have been optimized for
the fuseless load feeders. These include the top-connected,
All 3RA2 load feeders described here are designed for normal transverse auxiliary switch on the motor starter protector, which
starting, in other words for overload tripping times of less is available in a range of different versions. Special auxiliary
than 10 s (CLASS 10). At rated-load operating temperature switches that can be snapped on from below are available for
the tripping times are shorter, depending on the particular the contactor. These two accessories enable the fuseless load
equipment and the setting range. The exact values can be feeders to be wired simply without having to route cables
derived from the tripping characteristics of the motor starter through the device.
protectors.
Connection methods Incoming power supply

For all 3RA2 feeders up to 32 A, spring-loaded terminals are In total, four different energy supply options are available
available as well as screw terminals. To connect two devices (see "3RV29 infeed system for load feeders" on page 8/56).
with spring-loaded terminals, there are plug-in link module for Customer assembly of fuseless load feeders
sizes S00 and S0 which enable very quick mounting of the
feeders and a vibration-resistant assembly. Whereas preassembled 3RA2s can be ordered up to 65 A,
combinations in size S3 up to 100 A (approx. 45 kW/400 V)
To connect a motor starter protector with screw terminals to are also possible for customer assembly.
a contactor with spring-loaded terminals there are special
hybrid link modules for the sizes S00 and S0. The standard devices can be combined optimally – in terms
of both technical specifications and dimensions, thanks to the
Screw terminals modular system of the SIRIUS series.
The fuseless load feeders can thus be assembled easily by
the customer. It is simply necessary to assemble the standard
Spring-loaded terminals 3RV2 motor starter protector, the 3RT2 contactor and the
appropriate assembly kit.
The terminals are indicated in the corresponding tables For single devices and assembly kits, see the "Selection
by the symbols shown on orange backgrounds. and ordering data" for 3RA21 direct-on-line starters and
3RA22 reversing starters, page 8/22 or 8/34 onwards.
Use of load feeders in conjunction with IE3 and IE4 motors
For assembly kits for direct-on-line starting or reversing
Note: operation for mounting onto DIN rails or busbars, see page 8/50.
For the use of SIRIUS 3RA2 load feeders in conjunction For size S3 direct-on-line starters and sizes S0, S2 and S3
with highly efficient IE3 and IE4 motors, please observe the reversing starters, it is imperative that a DIN-rail adapter is used
8

information on dimensioning and configuring, see Application to ensure the necessary mechanical strength. If a busbar
Manual. adapter is used (not possible for size S3) then a DIN-rail adapter
For more information, see page 1/8. is not necessary.
3RA2 complete units SENTRON 3VA circuit breakers and SIRIUS 3RT contactors are
available for rated currents >100 A.
The 3RA2 fuseless load feeders can be ordered as preassem-
bled complete units for direct-on-line starting (3RA21) or for Single devices for customer assembly can be ordered if other
reversing operation (3RA22) with screw or spring-loaded termi- rated control supply voltages are required. Assembly kits can be
nals. From size S2, complete units for direct-on-line starting used to facilitate assembly.
(3RA21) are only available with screw terminals. Customers can also assemble tested combinations of motor
There are control supply voltages available of 50 Hz 230 V AC starter protectors with electronic controls (soft starters, solid-
and 24 V DC. state contactors) and load feeders with additional monitoring
and control devices (3RR monitoring relays, SIMOCODE 3UF).
A distinction is also drawn between whether the feeder is
mounted on a 35 mm DIN rail, on a flat surface using screws, For the electrical and mechanical connection of protection
or on a 60 mm busbar system. equipment and controls, there are prefabricated assembly kits
(link modules, wiring kits and DIN-rail or busbar adapters).
3RA21 load feeders in the S0 size must be configured on
DIN-rail adapters if high vibration and shock loads (railways, The following types of configuration are possible:
Kraftwerk Union, etc.) are involved. • Direct-on-line/reversing starting
• Star-delta (wye-delta) starting
A vibration and shock kit is available for mounting on busbar
• Solid-state/soft starting
adapters.
For more information and assignment tables for combinations of
Accessories the 3RA2 generation for self-assembly, see
As the 3RA2 fuseless load feeders are constructed from • Configuration Manual for load feeders,
3RV2 motor starter protectors and 3RT2 contactors, the same https://support.industry.siemens.com/cs/ww/en/view/39714188
accessories – such as auxiliary switches, undervoltage releases
• Equipment Manual,
or door-coupling rotary operating mechanisms – can be used for
https://support.industry.siemens.com/cs/ww/en/view/60284351
the 3RA2 fuseless load feeders as for these motor starter
protectors and contactors.

8/6 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Customer assembly of fused load feeders The function modules perform not only the communication
(contactor operation and feedback, ready signal) but also the
The flexible, modular system of SIRIUS also enables the electrical interlocking (for reversing and star-delta (wye-delta)
configuration of fused load feeders up to 100 A (approx. starters) and the timing relay function (star-delta (wye-delta)
45 kW/400 V). Up to 32 A is also available for 45 mm installation reversing time).
widths.
Communication information and control supply voltages are
Compact 3NW7...-1 cylindrical fuse holders for IEC fuses size passed on through ribbon cables so that the complete control
10 x 38 mm, or 3NW7...-1HG holders for Class CC UL fuses, current wiring on the starter is no longer needed.
can be used for this purpose.
More information:
For more information about fuse systems, see Catalog LV 10.
• AS-Interface see page 2/19 onwards
Communication link through IO-Link • 3RA27 function modules, see pages 3/73, 3/80 and 3/101
Load feeders can also be assembled with IO-Link for connection
to the higher-level control system. For each feeder, this requires Contactors with voltage tap
a contactor with a voltage tap onto which a 3RA2711 function For configuring load feeders with communication links
module is plugged (various versions for direct-on-line, reversing (AS-i/IO-Link), contactors with voltage taps are required. These
and star-delta (wye-delta) starters). The design of the SIRIUS contactors are not included as standard in the preassembled
load feeders permits a group of up to four SIRIUS controls to be 3RA2 load feeders. A load feeder with communication link must
conveniently connected through the standardized open system be assembled therefore from single devices.
IO-Link to a control system, thus reducing wiring considerably
compared to the conventional parallel wiring method. The electrical Complete integration in the automation landscape
connection is made using only three standard cables. As the result of the communication link through IO-Link or AS-i,
The function modules perform not only the communication the SIRIUS load feeders are fully integrated in the automation
(contactor operation and feedback, ready signal) but also the landscape and can draw on all the advantages of TIA
electrical interlocking (for reversing and star-delta (wye-delta) (e.g. integration in the TIA Maintenance Station).
starters) and the timing relay function (star-delta (wye-delta) Mounting
reversing time).
3RA2 fuseless load feeders can be supplied:
Communication information and control supply voltages are
passed on through ribbon cables so that the complete control • For mounting onto TH 35 DIN rails according to IEC 60715
current wiring on the feeder is no longer needed. (depth 15 mm)
The monitoring and maintenance of a plant is made • For mounting onto busbar adapters (busbar center-to-center
clearance 60 mm, busbar thickness 5 to 10 mm with beveled

8
considerably easier by transmitting diverse diagnostics data
from the function modules (e.g. missing main and auxiliary edges)
voltage, local disconnection…) through IO-Link to the higher- The fuseless load feeders are also suitable for screw fixing using
level control system. Also, feeders equipped for IO-Link can be two 3RV2928-0B push-in lugs.
conveniently controlled from the control cabinet door using the
optional operator panel. 3RA2 fuseless load feeders can also be installed using the
3RV29 infeed system (S0 and S00 only, see page 7/67).
More information:
• IO-Link, see page 2/88 onwards
• 3RA27 function modules, see pages 3/73, 3/80 and 3/101
Communication link through AS-Interface
Connection of the load feeders to the higher-level control
system is possible not only through IO-Link but also through
AS-Interface. The AS-Interface connection is recommended
wherever load feeders are used in distributed applications.
In this case, too, a contactor with a voltage tap is required with
a corresponding 3RA2712 function module (various versions
for direct-on-line, reversing and star-delta (wye-delta) starters).
The devices are implemented in A/B technology, making it easy
to connect up to 62 feeders to an AS-i master (regardless of
whether they are direct-on-line, reversing or star-delta (wye-
delta) starters). This results in a significant reduction of wiring
compared to the conventional parallel wiring method.
The electrical connection is made using standard cables.

Siemens IC 10 · 2023 8/7


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Direct-on-line starting • For DIN-rail mounting or screw fixing • Sizes S00 and S0

1 1 1 1 2 push-in lugs
3RV2928-0B
(only for screw fixing)
2 Motor starter protector
Size S00/S0
3 Screw terminals
2 2
3 Motor starter protector
Size S00/S0
Spring-loaded terminals
4 Link module
(Screw terminals)
3RA1921-1DA00 (for S00)
3RA2921-1AA00 (for S0, AC contactor)
3RA2921-1BA00 (for S0, DC contactor)
5 Link module
(Spring-loaded terminals)
4 5 3RA2911-2AA00 for S00
6 3RA2921-2AA00 for S0
6 Link module
(Hybrid)
3RA2911-2FA00 for S00
3RA2921-2FA00 for S0
7 Contactor
8 8 Size S00/S0
7 Screw terminals
IC01_00636

8 Contactor
Size S00/S0
Spring-loaded terminals
8

Left: 3RA21 load feeder with screw terminals


Center: 3RA21 load feeder with spring-loaded terminals
Right: Combination of motor starter protector with screw terminals and contactor with spring-loaded terminals

1 1 1 2 push-in lugs
3RV2928-0B
(only for screw fixing)

2 Motor starter protector


3 Size S00/S0
2 Screw terminals
3 Motor starter protector
Size S00/S0
Screw terminals/spring-loaded terminals
4 Link module
3RA2921-1BA00 (Screw terminals)
5 Link module
3RA2921-1BA00 for S00/S0 and screw terminals
3RA2911-2GA00 for S00 and spring-loaded terminals
3RA2921-2GA00 for S0 and spring-loaded terminals
4 6 Solid-state switching device (Screw terminals)
5
7 Soft starter
Size S00/S0
Screw terminals/spring-loaded terminals

7
IC01_00637

Left: Combination of motor starter protector and solid-state switching device with screw terminals
Right: Combination of motor starter protector and soft starter with spring-loaded terminals

8/8 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Direct-on-line starting • For DIN-rail mounting • Size S2

2 3 1 Motor starter protector


Size S2
Screw terminals
2 DIN-rail adapter (optional)
3RA2932-1AA00
Alternatively, the device can be mounted
on two DIN rails spaced at a distance of
175 mm without a DIN-rail adapter.
1 1
3 DIN-rail adapter
3RA2932-1CA00
4 Link module
3RA2931-1AA00
Screw terminals
5 Contactor
Size S2
Screw terminals

IC01_00638
6 Soft starter
Size S2
Screw terminals
4 4

5 6

8
Left: 3RA21 load feeder with screw terminals
Right: Combination of motor starter protector and soft starter with screw terminals

Siemens IC 10 · 2023 8/9


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Direct-on-line starting • For DIN-rail mounting • Size S3

2 1 Motor starter protector


3 Size S3
Screw terminals
2 DIN-rail adapter
3RA2942-1AA00
1 1 3 Mounting plate
4 Link module
3RA1941-1AA00
Screw terminals
5 Contactor
Size S3
Screw terminals
6 Soft starter
Size S3
Screw terminals
4 4

5 6

IC01_00655b
8

3RA21 load feeder for direct-on-line starting and DIN-rail mounting in size S3
(the version with screw terminals is shown in the picture)

Direct-on-line starting • For 60 mm busbar systems • Sizes S00 and S0

1 2 1 60 mm busbar adapter
for screw terminals
8US1251-5DS10 for S00
8US1251-5NT10 for S0
2 60 mm busbar adapter
for spring-loaded terminals
8US1251-5DT11 for S00
8US1251-5NT11 for S0
3 4
3 Motor starter protector
Size S00/S0
Screw terminals
4 Motor starter protector
Size S00/S0
Spring-loaded terminals
5 Link module
Screw terminals
3RA1921-1DA00 for S00
3RA2921-1AA00 for S0, AC contactor
IC01_00639

5 3RA2921-1BA00 for S0, DC contactor


6 6 Link module
3RA2911-2AA00 for S00
3RA2921-2AA00 for S0
(additional 3RA2911-1CA00 spacer
for height compensation on AC contactors
size S0 with spring-loaded terminals)

8 7 Contactor
7 Size S00/S0
Screw terminals
8 Contactor
Size S00/S0
Spring-loaded terminals

Left: 3RA21 load feeder for direct-on-line starting with busbar adapter with screw terminals
Right: 3RA21 load feeder for direct-on-line starting with busbar adapter with spring-loaded terminals

8/10 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Direct-on-line starting • For 60 mm busbar systems • Size S2

1 Motor starter protector


2 Size S2
Screw terminals
2 Busbar adapter 60 mm
8US1261-6MT10
3 Link module
3RA2931-1AA00
Screw terminals
1 4 Contactor
Size S2
Screw terminals
IC01_00640

8
3RA21 load feeder for direct-on-line starting with busbar adapter with screw terminals

Siemens IC 10 · 2023 8/11


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Reversing operation • For DIN-rail mounting or screw fixing • Size S00

1 1 1 Push-in lug
3RV2928-0B
(only for screw fixing)
2 Motor starter protector
3 Size S00/S0
2
Screw terminals
3 Motor starter protector
Size S00/S0
Spring-loaded terminals
4 Link module
Screw terminals
3RA1921-1DA00 for S00
3RA2921-1AA00 for S0, AC contactor
3RA2921-1BA00 for S0, DC contactor
5 Link module
Spring-loaded terminals
4 5 3RA2911-2AA00 for S00
3RA2921-2AA00 for S0
6 Contactor
Size S00/S0
Screw terminals
7 Contactor
Size S00/S0
e Spring-loaded terminals

6 a

6 7
c
7
g
8

IC01_00641

b f

Wiring kit Wiring kit


3RA2913-2AA1 3RA2913-2AA2
a Upper wiring module e Upper wiring module
b Lower wiring module f Lower wiring module
c Two connecting clips for two contactors g Two connecting clips for two contactors
d Mechanical interlock h Mechanical interlock
(can be removed if necessary) (can be removed if necessary)

Left: 3RA22 load feeder with screw terminals with push-in lugs with two contactors for reversing operation and
wiring kit 3RA2913-2AA1 for connecting the contactors (including mechanical interlocking and connecting clips)
Right: 3RA22 load feeder with spring-loaded terminals with push-in lugs with two contactors for reversing operation and
wiring kit 3RA2913-2AA2 (including mechanical interlocking and connecting clips)

8/12 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Reversing operation • For DIN-rail mounting • Size S0

2
2 RH assembly kit for reversing operation and
DIN-rail mounting in size S0

Screw terminals
3RA2923-1BB1
Spring-loaded terminals
1)
3RA2923-1BB2
1 Consisting of:
• Wiring kit for the
main and auxiliary circuits
• Two DIN-rail adapters
• Two connecting wedges
• Mechanical interlock
• Two connecting clips
• Fixing accessories

1 Motor starter protector


Size S0
3 Screw terminals/spring-loaded terminals
2 DIN-rail adapters
3RA2922-1AA00
with two connecting wedges
8US1998-1AA00
3 Link module
a Screw terminals
3RA2921-1AA00 for S0, AC contactor
4 3RA2921-1BA00 for S0, DC contactor
4 Spring-loaded terminals
c 3RA2921-2AA00
2)

4 Contactor
IC01_00642

Size S0

8
d Screw terminals/spring-loaded terminals
Wiring kit
Screw terminals
3RA2923-2AA1
Spring-loaded terminals
3RA2923-2AA2
a Upper wiring module
b
b Lower wiring module
c Two connecting clips for two contactors
d Mechanical interlock
(can be removed if necessary)

1) Contains two 3RA2911-1CA00 spacers for


height compensation on AC contactors size S0
with spring-loaded terminals.
2)
Additionally two 3RA2911-1CA00 spacers
for height compensation on AC contactors
size S0 with spring-loaded terminals.

3RA22 load feeder for reversing operation and DIN-rail mounting in size S0
(the version with screw terminals is shown in the picture)
RH mounting kits for reversing operation and DIN-rail mounting
in size S0, see page 8/52.

Siemens IC 10 · 2023 8/13


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Reversing operation • For DIN-rail mounting • Size S2

2 RH assembly kit for reversing operation and


2 DIN-rail mounting in size S2

3RA2933-1BB1
Consisting of:
• Wiring kit for the
main and auxiliary circuits
• Two DIN-rail adapters
1
• Two side modules
• Four connecting wedges
• Mechanical interlock
• Two connectors for two contactors
• Fixing accessories

1 Motor starter protector


Size S2
Screw terminals
2 DIN-rail adapter
IC01_00643

3RA2932-1AA00
with two side modules
3 3RA2902-1B
and four connecting wedges
8US1998-1AA00
3 Link module
3RA2931-1AA00
Screw terminals
4 Contactor
a
Size S2
4 Screw terminals
4 c
Wiring kit
d
8

Screw terminals
3RA2933-2AA1
a Upper wiring module
b Lower wiring module
c Two connectors for two contactors
d Mechanical interlock
3RA2934-2B (not part of the wiring
kit, must be ordered separately)

3RA22 load feeder for reversing operation and DIN-rail mounting in size S2
(the version with screw terminals is shown in the picture)
RH mounting kits for reversing operation and DIN-rail mounting
in size S2, see page 8/52.

8/14 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Reversing operation • For DIN-rail mounting • Size S3

2 RH assembly kit for reversing operation and


2 DIN-rail mounting in size S3
3RA2943-1BB1
Consisting of:
• Wiring kit for the
1
main and auxiliary circuits
• Two DIN-rail adapters
• Three side modules
• Six connecting wedges
• Mechanical interlock
• Two connectors for two contactors
• Fixing accessories

1 Motor starter protector


Size S3
IC01_00656b
2 DIN-rail adapter
3
3RA2942-1AA00
with two side modules
3RA2902-1B
and four connecting wedges
8US1998-1AA00
3 Link module
a 3RA1941-1AA00
4 Contactor
4 Size S3
c
4
d Wiring kit
Screw terminals
3RA2943-2AA1
a Upper wiring module
b Lower wiring module

8
c Two connectors for two contactors
d Mechanical interlock
3RA2934-2B (not part of the wiring kit,
must be ordered separately)
b

3RA22 load feeder for reversing operation and DIN-rail mounting in size S3
(the version with screw terminals is shown in the picture)
RH mounting kits for reversing operation and DIN-rail mounting
in size S3, see page 8/52.

Siemens IC 10 · 2023 8/15


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Reversing operation • For 60 mm busbar systems • Sizes S00 and S0

3 RS assembly kit for reversing operation


3
and busbar mounting in size S00/S0

Screw terminals
3RA2913-1DB1 for S00
3RA2923-1DB1 for S0
Spring-loaded terminals
3RA2913-1DB2 for S00
1 3RA2923-1DB2 for S0 1)
Consisting of:
• Wiring kit for the
main and auxiliary circuits
• Busbar adapter
• Device holder
• Two connecting wedges
• Mechanical interlock
• Two connecting clips for two contactors
• Fixing accessories

2 1 Motor starter protector


Size S00/S0
Screw terminals/spring-loaded terminals
2 Link module
Screw terminals
3RA1921-1DA00 for S00
3RA2921-1AA00 for S0, AC contactor
a 3RA2921-1BA00 for S0, DC contactor
Spring-loaded terminals
4 3RA2911-2AA00 for S00
4 3RA2921-2AA00 for S0 2)
c
3 60 mm busbar adapter
8

Screw terminals
IC01_00644a

8US1251-5DS10 for S00/S0


8US1251-5NT10 for S0
d Wiring kit
Screw terminals Spring-loaded terminals
3RA2913-2AA1 for S00 8US1251-5DT11 for S00/S0
3RA2923-2AA1 for S0 8US1251-5NT11 for S0
Spring-loaded terminals With two connecting wedges
3RA2913-2AA2 for S00 8US1998-1AA10
3RA2923-2AA2 for S0 60 mm device holder
b a Upper wiring module 8US1250-5AS10 or
8US1250-5AT10
b Lower wiring module (according to length of left adapter)
c Two connecting clips for two contactors 4 Contactor
d Mechanical interlock Size S00/S0
(can be removed if necessary) Screw terminals/spring-loaded terminals

1) Contains two 3RA2911-1CA00 spacers


for height compensation on AC contactors
size S0 with spring-loaded terminals.
2) Additionally two 3RA2911-1CA00 spacers
for height compensation on AC contactors
size S0 with spring-loaded terminals.

3RA22 load feeder for reversing operation and 60 mm busbar


(the version with screw terminals is shown in the picture)
RS mounting kits for reversing operation and busbar mounting
in size S00/S0, see page 8/54.

8/16 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Reversing operation • For 60 mm busbar systems • Size S2

RS assembly kit for reversing operation and


busbar mounting in size S2
2
3RA2933-1DB1
Consisting of:
• Wiring kit for the
main and auxiliary circuits
• Busbar adapter
1 • Mechanical interlock
• Two connectors for two contactors
• Fixing accessories

1 Motor starter protector


Size S2
Screw terminals
2 Busbar adapter 60 mm
8US1211-6MT10
3 Link module
3RA2931-1AA00
Screw terminals
3 4 Contactor
Size S2
Screw terminals
Wiring kit
Screw terminals
3RA2933-2AA1
a Upper wiring module
b Lower wiring module
c Two connectors for two contactors
a

8
d Mechanical interlock
4 c 4 3RA2934-2B (not part of the wiring kit,
must be ordered separately)
d
IC01_00645

3RA22 load feeder for reversing operation and 60 mm busbar in size S2


(the version with screw terminals is shown in the picture)
RS mounting kits for reversing operation and busbar mounting
in size S2, see page 8/54.

Siemens IC 10 · 2023 8/17


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data
Article number scheme

Product versions Article number


SIRIUS load feeders 3RA2 @ @ 0 – @ @ @ @ @ – @ @ @ @
Product function Direct-on-line starter 1 For motor standard output 0.06 ... 45 kW
Reversing starter 2 For motor standard output 0.06 ... 45 kW
Size S00 1
S0 2
e.g. 3 = S2 @ At Iq = 100 kA at 400 V
e.g. 5 = S2 @ At Iq = 150 kA at 400 V
Setting range of the e.g. 0B = 0.14 ... 0.2 A @@
overload release
Assembly, e.g. A = S00, S0, S2 @ Direct mounting, screw terminals
assembly type,
connection method
Contactor size, rated e.g. 15 = S00/3 kW @@
power at 400 V AC
Version e.g. 0 = S0, S2 @ 1 NO + 1 NC integrated in contactor
Auxiliary switches e.g. 1 = S00 @ 1 NO integrated in contactor
on the contactor
e.g. 2 = S00 @ 1 NC integrated in contactor
Operating range e.g. A = S00, S0, S2 @ AC 0.8 x Us min ... 1.1 x Us max,
of solenoid coil standard coil without RC circuit
(contactor)
Rated control supply 230 V AC P 0 50/60 Hz AC for S00, 50 Hz AC for S0 ... S3
voltage (contactor) 24 V DC B 4
Example 3RA2 1 1 0 – 0 B A 1 5 – 1 A P 0

Note:
The article number scheme shows an overview of product
8

versions for better understanding of the logic behind the


article numbers.
For your orders, please use the article numbers quoted in
the selection and ordering data.

■ Benefits
• Minimum planning and assembly work and far less wiring • Uniform accessories for sizes S00, S0, S2 and S3
with the preassembled complete units (only one article • Spring-loaded terminals possible throughout: Enhanced
number 3RA2) operational reliability (vibration-resistant wiring) and less
• Plug-in connectors from the motor starter protector to all types wiring work thanks to plug-in connections (S00 and S0 only)
of SIRIUS controls, for quicker and error-free assembly of • Power loss 5 to 10% smaller than for comparable devices,
feeders with screw and spring-loaded terminals hence lower energy consumption
• High planning reliability through consistent combination • Connection of feeders to the control system through
tests for fuseless and fused configuration in accordance standardized system connection (IO-Link and AS-i),
with IEC and UL/CSA for fast integration in TIA and less wiring work
• Comprehensive approvals for use world-wide on request,
see page 16/9 onwards.
• High operational reliability through short-circuit breaking
capacity of 150 kA with type of coordination "1" and "2"

8/18 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data

■ Technical specifications
More information
Industry Mall, see www.siemens.com/product?3RA2 FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16289/faq
Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/60284351
Configuration Manual, see
https://support.industry.siemens.com/cs/ww/en/view/39714188

Direct-on-line starters/ Size Connection method Mounting Control voltage Width W Height H Depth D
reversing starters
mm mm mm
Mounting dimensions
Direct-on-line starters S00 Screw terminals DIN rails AC/DC 45 167 97
3RA21. 3RA211. Busbar adapters AC/DC 45 200 155
(Size S3 or larger is only Spring-loaded terminals DIN rails AC/DC 45 198 97
available for self-assembly) Busbar adapters AC/DC 45 260 155
S0 Screw terminals DIN rails AC 45 193 97
3RA212. DC 45 193 107
H

Busbar adapters AC 45 260 155


DC 45 260 165
D

W
Spring-loaded terminals DIN rails AC/DC 45 243 107
Busbar adapters AC/DC 45 260 165
S2 Screw terminals DIN rails AC/DC 55 274 150
3RA213./3RA215. Busbar adapters AC/DC 55 350 208
S3 Screw terminals DIN-rail adapters AC/DC 70 333 198
(self-assembly only)
Reversing starters S00 Screw terminals DIN rails AC/DC 90 170 97
3RA22. 3RA221. Busbar adapters AC/DC 90 200 155

8
(Size S2 or larger is only Spring-loaded terminals DIN rails AC/DC 90 204 97
available for self-assembly) Busbar adapters AC/DC 90 260 155
S0 Screw terminals DIN-rail adapters AC 90 265 120.3
3RA222. DC 90 265 130
Busbar adapters AC 90 260 155
DC 90 260 165
Spring-loaded terminals DIN-rail adapters AC/DC 90 270 131
Busbar adapters AC/DC 90 260 165
S2 Screw terminals DIN rails AC/DC 120 295 175
(self-assembly only) Busbar adapters AC/DC 120 361 208
S3 Screw terminals DIN-rail adapters AC/DC 150 333 198
(self-assembly only)

Type 3RA2.1 3RA2.2 3RA213, For self-assembly


3RA215
Size S00 S0 S2 S3
Number of poles 3 3 3 3
Mechanics and environment
Permissible ambient temperature
• During operation °C -20 ... +60
• During storage and transport °C -55 ... +80
Weight kg 0.6 ... 1.5 0.8 ... 2.3 2.2 ... 2.5 4.0 ... 4.2
Permissible mounting position 22,5° 22,5°
NSB0_00369

90° 90°

Important: According to DIN 43602 start command "I" at the right or top
Shock resistance IEC 60068-2-27 g/ms 6/11 (sine pulse) On request
Degree of protection IP on the front According to IP20
IEC 60529
Touch protection on the front According to Finger-safe for vertical touching from the front
IEC 60529

Siemens IC 10 · 2023 8/19


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data

Type 3RA2.1 3RA2.2 3RA213, For self-assembly


3RA215
Size S00 S0 S2 S3
Number of poles 3 3 3 3
Electrical specifications
Standards • IEC 60947-1, EN 60947-1
(VDE 0660 Part 100)
• IEC 60947-2; EN 60947-2
(VDE 0660 Part 101)
• IEC 60947-4-1, EN 60947-4-1
(VDE 0660 Part 102)
Max. rated current In max A 16 32 65 100
(= max. rated operational current Ie)
Rated operational voltage Ue V 690
Rated frequency Hz 50/60
Rated insulation voltage Ui V 690
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 6
Trip class (CLASS) According to 10
IEC 60947-4-1,
EN 60947-4-1
(VDE 0660 Part 102)
Rated short-circuit current Iq According to kA 150 3RA213: 100 With 3RV2041: 100
At 50/60 Hz 400 V AC IEC 60947-4-1, 3RA215: 150 With 3RV2042: 150
EN 60947-4-1
(VDE 0660 Part 102)
Types of coordination According to See "Selection and ordering data", page 8/22 onwards
IEC 60947-4-1,
EN 60947-4-1
(VDE 0660 Part 102)
Power loss Pv of all main conducting paths See technical specifications of the individual devices:
Dependent on rated current In • "Switching Devices - Contactors and Contactor Assemblies", page 3/25 onwards
(upper setting range)
• "Protection Equipment"  "Motor starter protectors/circuit breakers", page 7/18
onwards
8

Power consumption of the solenoid coils with contactors See technical specifications of the contactor, page 3/26 onwards
Solenoid coil operating range with contactors
Endurance of the motor starter protector
• Mechanical endurance Oper- 100 000 Up to 52 A: 50 000 25 000
ating
cycles
• Electrical endurance Oper- 100 000 From 59 A: 20 000 25 000
ating
cycles
• Max. switching frequency per hour (motor starts) 1/h 15
Endurance of contactor
• Mechanical endurance Oper- 30 million 10 million
ating
cycles
• Electrical endurance Oper- See endurance characteristic curves of the contactors, page 3/26 onwards
ating
cycles
Phase failure sensitivity According to ✓
of the motor starter protector IEC 60947-1,
EN 60947-1
(VDE 0660 Part 102)
Isolating features of the According to ✓
motor starter protector IEC 60947-2,
EN 60947-2
(VDE 0660 Part 101)
Main and EMERGENCY STOP switch According to ✓
characteristics of the motor starter IEC 60204-1, (With overvoltage releases of category "1"
protector and accessories EN 60204-1 under conditions of proper use)
(VDE 0113 Part 1)
Protective separation between main and According to V Up to 400
auxiliary circuits EN 60947-1, Annex N
Mirror contacts for contactors ✓
Integrated auxiliary switches According to IEC 60947-4-1, Annex F
✓ Function available

8/20 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
General data

Conductor cross-sections of main circuit


Type 3RA2.10 3RA2.20 3RA2130-4E..., 3RA2130-4W..., For
3RA2130-4P..., 3RA2130-4X..., self-assembly
3RA2130-4U..., 3RA2130-4J...,
3RA2130-4V... 3RA2130-4K...,
3RA2150
Size S00 S0 S2 S3
Connection type Screw terminals Screw terminals
with box
terminal
Terminal screw M3, M4, M6, 4 mm Allen screw
Pozidriv size 2 Pozidriv size 2 Pozidriv size 2
Operating devices mm  5 ... 6  5 ... 6  5 ... 6 Allen screw
Prescribed tightening torque Nm 0.8 ... 1.2 2 ... 2.5 3.0 ... 4.5 4.5 ... 6
Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
• Solid or stranded mm2 2 x (0.75 ... 2.5)1), 2 x (1 ... 2.5)1), 2 x (1 ... 25)1), 2 x (1 ... 35)1), 2 x (2.5 ... 16)1)
2 x (0.5 ... 1.5)1), 2 x (2.5 ... 10)1) 1 x (1 ... 35)1) 1 x (1 ... 50)1) 2 x (10 ... 50)1),
for contactor only 1 x (10 ... 70)1)
2x4
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)1), 2 x (1 ... 2.5)1), 2 x (1 ... 16)1), 2 x (1 ... 25)1), 2 x (2.5 ... 35)1),
2 x (0.75 ... 2.5)1) 2 x (2.5 ... 6)1), 1 x (1 ... 25)1) 1 x (1 ... 35)1) 1 x (2.5 ... 50)1)
1 x 10
• AWG cables, solid or stranded AWG 2 x (20 ... 16)1), 2 x (16 ... 12)1), 2 x (18 ... 3)1), 2 x (18 ... 2)1), 2 x (10 ... 1/0)1)
for contactor only 2 x (14 ... 8)1) 1 x (18 ... 2)1) 1 x (18 ... 1)1) 1 x (10 ... 2/0)1)
2 x (18 ... 14)1),
2 x 12
• Ribbon cable conductors mm -- 2 x (6 x 9 x 0.8)
(Number x Width x Thickness)
Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5 and 3.5 x 0.5


Conductor cross-sections (min./max.),
1 or 2 conductors can be connected

8
• Solid or stranded mm2 2 x (0.5 ... 4) 2 x (1 ... 10) --
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5) 2 x (1 ... 6) --
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 2.5) 2 x (1 ... 6) --
• AWG cables, solid or stranded AWG 2 x (20 ... 12) 2 x (18 ... 8) --
Max. external diameter of the conductor insulation mm 3.6 3.6 --
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must be in the range specified.

Conductor cross-sections for auxiliary and


control circuits
Type 3RA2110 3RA2120 3RA2130 For self-assembly
3RA2210 3RA2220 3RA2150
Size S00 S0 S2 S3
Connection type Screw terminals

Terminal screw M3, Pozidriv size 2


Operating devices mm  5 ... 6
Prescribed tightening torque Nm 0.8 ... 1.2
Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
• Solid or stranded mm2 2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1)
2
• Finely stranded with end sleeve (DIN 46228) mm 2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1)
• AWG cables, solid or stranded AWG 2 x (18 ... 14)1), 2 x (20 ... 16)1), 2 x 12 for contactor S00 only
Connection type Spring-loaded terminals

Operating devices mm 3.0 x 0.5 and 3.5 x 0.5


Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
• Solid or stranded mm2 2 x (0.5 ... 2.5)
• Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5)
• Finely stranded with end sleeve (DIN 46228) mm2 2 x (0.5 ... 1.5)
• AWG cables, solid or stranded AWG 2 x (20 ... 14)
Max. external diameter of the conductor insulation mm 3.6
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must be in the range specified.

Siemens IC 10 · 2023 8/21


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA21 direct-on-line starters > for DIN-rail mounting or screw fixing IE3 ready IE4 ready IE3/IE4 ready
AC-3e

■ Selection and ordering data


Direct-on-line starting Rated control supply voltage
50/60 Hz 230 V AC for S00, 50 Hz 230 V AC for S0,
S2 and S3
With screw terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
Contactor size S00: 1 NO,
3RA2110 3RA2120 3RA2150 Contactor sizes S0, S2 and S3: 1 NO + 1 NC
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC3) of the inverse-
time delayed
Standard Motor overload Motor + Contactor + Link Screw terminals
output current I release starter module
P (guide protector
value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA10 15-1AP01 1921-1DA00 3RA2110-0BA15-1AP0 1 1 unit 41D
8

0.06 0.2 0.18 ... 0.25 11-0CA10 3RA2110-0CA15-1AP0 1 1 unit 41D


0.09 0.3 0.22 ... 0.32 11-0DA10 3RA2110-0DA15-1AP0 1 1 unit 41D
0.09 0.3 0.28 ... 0.4 11-0EA10 3RA2110-0EA15-1AP0 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA10 3RA2110-0FA15-1AP0 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA10 3RA2110-0GA15-1AP0 1 1 unit 41D
0.18 0.6 0.55 ... 0.8 11-0HA10 3RA2110-0HA15-1AP0 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA10 3RA2110-0JA15-1AP0 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA10 3RA2110-0KA15-1AP0 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA10 3RA2110-1AA15-1AP0 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA10 3RA2110-1BA15-1AP0 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA10 3RA2110-1CA15-1AP0 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA10 3RA2110-1DA15-1AP0 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA10 3RA2110-1EA15-1AP0 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 11-1FA10 24-1AP00 2921-1AA00 3RA2120-1FA24-0AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 3RA2120-1GA24-0AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2120-1HA24-0AP0 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 3RA2120-1JA24-0AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 3RA2120-1KA24-0AP0 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA10 26-1AP00 3RA2120-4AA26-0AP0 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA10 27-1AP00 3RA2120-4BA27-0AP0 1 1 unit 41D
11 22 16 ... 22 21-4CA10 3RA2120-4CA27-0AP0 1 1 unit 41D
11 22 18 ... 25 21-4DA10 3RA2120-4DA27-0AP0 1 1 unit 41D
15 28 23 ... 28 21-4NA10 3RA2120-4NA27-0AP0 1 1 unit 41D
15 294) 27 ... 32 21-4EA10 3RA2120-4EA27-0AP0 1 1 unit 41D
S2 15 29 22 ... 32 32-4EA10 35-1AP00 2931-1AA00 3RA2150-4EA35-0AP0 1 1 unit 41D
18.5 35 28 ... 36 32-4PA10 3RA2150-4PA35-0AP0 1 1 unit 41D
18.5 35 32 ... 40 32-4UA10 3RA2150-4UA35-0AP0 1 1 unit 41D
22 41 35 ... 45 32-4VA10 36-1AP00 3RA2150-4VA36-0AP0 1 1 unit 41D
22 41 42 ... 50 32-4WA10 3RA2150-4WA36-0AP0 1 1 unit 41D
30 55 49 ... 59 32-4XA10 37-1AP00 3RA2150-4XA37-0AP0 1 1 unit 41D
30 55 54 ... 65 32-4JA10 3RA2150-4JA37-0AP0 1 1 unit 41D
375) 66 62 ... 75 32-4KA10 38-1AP00 3RA2150-4KA38-0AP0 1 1 unit 41D
S3 Size S3 available on request Size S3 is only available for self-assembly

1)
Push-in lugs, see "Accessories", page 8/52.
2) Auxiliary switches, see "Accessories", page 8/45.
3)
The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
4) Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using size S2.
5)
Maximum permissible current setting at motor starter protector 65 A, as the
maximum permissible current of the 3RA2931-1AA00 link module is 65 A.

* You can order this quantity or a multiple thereof.


8/22 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
AC-3e E3 ready IE4 ready IE3/IE4 ready 3RA21 direct-on-line starters > for DIN-rail mounting or screw fixing

Direct-on-line starting Rated control supply voltage


50/60 Hz 230 V AC for S00
With screw terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
3RA2110 Contactor size S00: 1 NO
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC3) of the inverse-
time delayed
Standard Motor overload Motor + Contactor + Link Screw terminals
output current I release starter module
P (guide protector
value)
Article No. Basic
price
kW A A per PU
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
3RV20 3RT20 3RA ToC
1
S00 Load feeders for lower outputs, see table for type of
coordination "2" on the previous page.
1.5 3.6 3.5 ... 5 11-1FA10 15-1AP01 1921-1DA00 3RA2110-1FA15-1AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 3RA2110-1GA15-1AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2110-1HA15-1AP0 1 1 unit 41D

8
4 8.5 7 ... 10 11-1JA10 16-1AP01 3RA2110-1JA16-1AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 17-1AP01 3RA2110-1KA17-1AP0 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA10 18-1AP01 3RA2110-4AA18-1AP0 1 1 unit 41D
1)
Push-in lugs, see "Accessories", page 8/52.
2)
Auxiliary switches, see "Accessories", page 8/45.
3) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/23
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA21 direct-on-line starters > for DIN-rail mounting or screw fixing IE3 ready IE4 ready IE3/IE4 ready
AC-3e
Direct-on-line starting Rated control supply voltage
50 Hz 230 V AC for S2 and S3
With screw terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
3RA2130 Contactor sizes S2 and S3: 1 NO + 1 NC
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC3) of the inverse-
time delayed
Standard Motor overload Motor + Contactor + Link Screw terminals
output current I release starter module
P (guide protector
value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 100 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
3RV20 3RT20 3RA ToC
2
S2 15 29 22 ... 32 31-4EA10 35-1AP00 2931-1AA00 3RA2130-4EA35-0AP0 1 1 unit 41D
18.5 35 28 ... 36 31-4PA10 3RA2130-4PA35-0AP0 1 1 unit 41D
18.5 35 32 ... 40 31-4UA10 3RA2130-4UA35-0AP0 1 1 unit 41D
22 41 35 ... 45 31-4VA10 36-1AP00 3RA2130-4VA36-0AP0 1 1 unit 41D
22 41 42 ... 50 31-4WA10 3RA2130-4WA36-0AP0 1 1 unit 41D
8

30 55 49 ... 59 31-4XA10 37-1AP00 3RA2130-4XA37-0AP0 1 1 unit 41D


30 55 54 ... 65 31-4JA10 3RA2130-4JA37-0AP0 1 1 unit 41D
4)
37 66 62 ... 73 31-4KA10 38-1AP00 3RA2130-4KA38-0AP0 1 1 unit 41D
S3 Size S3 available on request Size S3 is only available for self-assembly

1)
Push-in lugs, see "Accessories", page 8/52.
2)
Auxiliary switches, see "Accessories", page 8/45.
3) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
4)
Maximum permissible current setting at motor starter protector 65 A, as the
maximum permissible current of the 3RA2931-1AA00 link module is 65 A.

* You can order this quantity or a multiple thereof.


8/24 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
AC-3e E3 ready IE4 ready IE3/IE4 ready 3RA21 direct-on-line starters > for DIN-rail mounting or screw fixing

Direct-on-line starting Rated control supply voltage


50/60 Hz 230 V AC for S00, 50 Hz 230 V AC for S0
With spring-loaded terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
Contactor size S00: 1 NO,
3RA2110 3RA2120 Contactor size S0: 1 NO + 1 NC
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC3) of the inverse-
time delayed
Standard Motor overload Motor + Contactor + Link Spring-loaded
output current I release starter module terminals
P (guide protector
value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA29 ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA20 15-2AP01 11-2AA00 3RA2110-0BE15-1AP0 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA20 3RA2110-0CE15-1AP0 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA20 3RA2110-0DE15-1AP0 1 1 unit 41D
0.09 0.3 0.28 ... 0.4 11-0EA20 3RA2110-0EE15-1AP0 1 1 unit 41D

8
0.12 0.4 0.35 ... 0.5 11-0FA20 3RA2110-0FE15-1AP0 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA20 3RA2110-0GE15-1AP0 1 1 unit 41D
0.18 0.6 0.55 ... 0.8 11-0HA20 3RA2110-0HE15-1AP0 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA20 3RA2110-0JE15-1AP0 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA20 3RA2110-0KE15-1AP0 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA20 3RA2110-1AE15-1AP0 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA20 3RA2110-1BE15-1AP0 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA20 3RA2110-1CE15-1AP0 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA20 3RA2110-1DE15-1AP0 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA20 3RA2110-1EE15-1AP0 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 21-1FA20 24-2AP00 21-2AA00 3RA2120-1FE24-0AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 21-1GA20 3RA2120-1GE24-0AP0 1 1 unit 41D
3 6.5 5.5 ... 8 21-1HA20 3RA2120-1HE24-0AP0 1 1 unit 41D
4 8.5 7 ... 10 21-1JA20 3RA2120-1JE24-0AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 21-1KA20 3RA2120-1KE24-0AP0 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA20 26-2AP00 3RA2120-4AE26-0AP0 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA20 27-2AP00 3RA2120-4BE27-0AP0 1 1 unit 41D
11 22 16 ... 22 21-4CA20 3RA2120-4CE27-0AP0 1 1 unit 41D
11 22 18 ... 25 21-4DA20 3RA2120-4DE27-0AP0 1 1 unit 41D
15 28 23 ... 28 21-4NA20 3RA2120-4NE27-0AP0 1 1 unit 41D
15 294) 27 ... 32 21-4EA20 3RA2120-4EE27-0AP0 1 1 unit 41D
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
S00 For load feeders for lower outputs, see this table at ToC
type of coordination "2". 1

1.5 3.6 3.5 ... 5 11-1FA20 15-2AP01 11-2AA00 3RA2110-1FE15-1AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA20 3RA2110-1GE15-1AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA20 3RA2110-1HE15-1AP0 1 1 unit 41D
4 8.5 7 ... 10 11-1JA20 16-2AP01 3RA2110-1JE16-1AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA20 17-2AP01 3RA2110-1KE17-1AP0 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA20 18-2AP01 3RA2110-4AE18-1AP0 1 1 unit 41D
1)
Push-in lugs, see "Accessories", page 8/52.
2) Auxiliary switches, see "Accessories", page 8/45.
3)
The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
4)
Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using size S2.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/25
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA21 direct-on-line starters > for DIN-rail mounting or screw fixing IE3 ready IE4 ready IE3/IE4 ready
AC-3e
Direct-on-line starting Rated control supply voltage 24 V DC
With screw terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
Contactor size S00: 1 NO,
3RA2110 3RA2120 3RA2150 Contactor sizes S0, S2 and S3: 1 NO + 1 NC
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC3) of the inverse-
time delayed
Standard Motor overload Motor + Contactor + Link Screw terminals
output current I release starter module
P (guide protector
value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA10 15-1BB41 1921-1DA00 3RA2110-0BA15-1BB4 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA10 3RA2110-0CA15-1BB4 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA10 3RA2110-0DA15-1BB4 1 1 unit 41D
0.09 0.3 0.28 ... 0.4 11-0EA10 3RA2110-0EA15-1BB4 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA10 3RA2110-0FA15-1BB4 1 1 unit 41D
8

0.18 0.6 0.45 ... 0.63 11-0GA10 3RA2110-0GA15-1BB4 1 1 unit 41D


0.18 0.6 0.55 ... 0.8 11-0HA10 3RA2110-0HA15-1BB4 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA10 3RA2110-0JA15-1BB4 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA10 3RA2110-0KA15-1BB4 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA10 3RA2110-1AA15-1BB4 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA10 3RA2110-1BA15-1BB4 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA10 3RA2110-1CA15-1BB4 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA10 3RA2110-1DA15-1BB4 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA10 3RA2110-1EA15-1BB4 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 11-1FA10 24-1BB40 2921-1BA00 3RA2120-1FA24-0BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 3RA2120-1GA24-0BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2120-1HA24-0BB4 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 3RA2120-1JA24-0BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 3RA2120-1KA24-0BB4 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA10 26-1BB40 3RA2120-4AA26-0BB4 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA10 27-1BB40 3RA2120-4BA27-0BB4 1 1 unit 41D
11 22 16 ... 22 21-4CA10 3RA2120-4CA27-0BB4 1 1 unit 41D
11 22 18 ... 25 21-4DA10 3RA2120-4DA27-0BB4 1 1 unit 41D
15 28 23 ... 28 21-4NA10 3RA2120-4NA27-0BB4 1 1 unit 41D
15 294) 27 ... 32 21-4EA10 3RA2120-4EA27-0BB4 1 1 unit 41D
S2 15 29 22 ... 32 32-4EA10 35-1NB30 2931-1AA00 3RA2150-4EA35-0NB3 1 1 unit 41D
18.5 35 28 ... 36 32-4PA10 3RA2150-4PA35-0NB3 1 1 unit 41D
18.5 35 32 ... 40 32-4UA10 3RA2150-4UA35-0NB3 1 1 unit 41D
22 41 35 ... 45 32-4VA10 36-1NB30 3RA2150-4VA36-0NB3 1 1 unit 41D
22 41 42 ... 50 32-4WA10 3RA2150-4WA36-0NB3 1 1 unit 41D
30 55 49 ... 59 32-4XA10 37-1NB30 3RA2150-4XA37-0NB3 1 1 unit 41D
30 55 54 ... 65 32-4JA10 3RA2150-4JA37-0NB3 1 1 unit 41D
375) 66 62 ... 73 32-4KA10 38-1NB30 3RA2150-4KA38-0NB3 1 1 unit 41D
S3 Size S3 available on request Size S3 is only available for self-assembly

1) Push-in lugs, see "Accessories", page 8/52.


2)
Auxiliary switches, see "Accessories", page 8/45.
3)
The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
4) Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using size S2.
5)
Maximum permissible current setting at motor starter protector 65 A, as the
maximum permissible current of the 3RA2931-1AA00 link module is 65 A.

* You can order this quantity or a multiple thereof.


8/26 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
AC-3e E3 ready IE4 ready IE3/IE4 ready 3RA21 direct-on-line starters > for DIN-rail mounting or screw fixing

Direct-on-line starting Rated control supply voltage 24 V DC


With screw terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
3RA2110 Contactor size S00: 1 NO
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC3) of the inverse-
time delayed
Standard Motor overload Motor + Contactor + Link Screw terminals
output current I release starter module
P (guide protector
value)
Article No. Basic
price
kW A A per PU
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
3RV20 3RT20 3RA ToC
1
S00 Load feeders for lower outputs, see table for type of
coordination "2" on the previous page.
1.5 3.6 3.5 ... 5 11-1FA10 15-1BB41 1921-1DA00 3RA2110-1FA15-1BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 3RA2110-1GA15-1BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2110-1HA15-1BB4 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 16-1BB41 3RA2110-1JA16-1BB4 1 1 unit 41D

8
5.5 11.5 9 ... 12.5 11-1KA10 17-1BB41 3RA2110-1KA17-1BB4 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA10 18-1BB41 3RA2110-4AA18-1BB4 1 1 unit 41D
1) Push-in lugs, see "Accessories", page 8/52.
2)
Auxiliary switches, see "Accessories", page 8/45.
3)
The actual starting and rated data of the motor to be protected must be
considered when selecting the units.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/27
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA21 direct-on-line starters > for DIN-rail mounting or screw fixing IE3 ready IE4 ready IE3/IE4 ready
AC-3e
Direct-on-line starting Rated control supply voltage 24 V DC
With screw terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
3RA2130 Contactor sizes S2 and S3: 1 NO + 1 NC
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC3) of the inverse-
time delayed
Standard Motor overload Motor + Contactor + Link Screw terminals
output current I release starter module
P (guide protector
value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 100 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
3RV20 3RT20 3RA ToC
2
S2 15 29 22 ... 32 31-4EA10 35-1NB30 2931-1AA00 3RA2130-4EA35-0NB3 1 1 unit 41D
18.5 35 28 ... 36 31-4PA10 3RA2130-4PA35-0NB3 1 1 unit 41D
18.5 35 32 ... 40 31-4UA10 3RA2130-4UA35-0NB3 1 1 unit 41D
22 41 35 ... 45 31-4VA10 36-1NB30 3RA2130-4VA36-0NB3 1 1 unit 41D
22 41 42 ... 50 31-4WA10 3RA2130-4WA36-0NB3 1 1 unit 41D
30 55 49 ... 59 31-4XA10 37-1NB30 3RA2130-4XA37-0NB3 1 1 unit 41D
8

30 55 54 ... 65 31-4JA10 3RA2130-4JA37-0NB3 1 1 unit 41D


374) 66 62 ... 73 31-4KA10 38-1NB30 3RA2130-4KA38-0NB3 1 1 unit 41D
S3 Size S3 available on request Size S3 is only available for self-assembly

1)
Push-in lugs, see "Accessories", page 8/52.
2)
Auxiliary switches, see "Accessories", page 8/45.
3) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
4)
Maximum permissible current setting at motor starter protector 65 A, as the
maximum permissible current of the 3RA2931-1AA00 link module is 65 A.

* You can order this quantity or a multiple thereof.


8/28 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
AC-3e E3 ready IE4 ready IE3/IE4 ready 3RA21 direct-on-line starters > for DIN-rail mounting or screw fixing

Direct-on-line starting Rated control supply voltage 24 V DC


With spring-loaded terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
Contactor size S00: 1 NO,
3RA2110 3RA2120 Contactor size S0: 1 NO + 1 NC
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response SET, M)
400 V AC3) value of the
inverse-time
Standard Motor delayed Motor + Contactor + Link Spring-loaded
output current I overload starter module terminals
P (guide release protector
value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA29 ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA20 15-2BB41 11-2AA00 3RA2110-0BE15-1BB4 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA20 3RA2110-0CE15-1BB4 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA20 3RA2110-0DE15-1BB4 1 1 unit 41D
0.09 0.3 0.28 ... 0.4 11-0EA20 3RA2110-0EE15-1BB4 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA20 3RA2110-0FE15-1BB4 1 1 unit 41D

8
0.18 0.6 0.45 ... 0.63 11-0GA20 3RA2110-0GE15-1BB4 1 1 unit 41D
0.18 0.6 0.55 ... 0.8 11-0HA20 3RA2110-0HE15-1BB4 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA20 3RA2110-0JE15-1BB4 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA20 3RA2110-0KE15-1BB4 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA20 3RA2110-1AE15-1BB4 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA20 3RA2110-1BE15-1BB4 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA20 3RA2110-1CE15-1BB4 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA20 3RA2110-1DE15-1BB4 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA20 3RA2110-1EE15-1BB4 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 21-1FA20 24-2BB40 21-2AA00 3RA2120-1FE24-0BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 21-1GA20 3RA2120-1GE24-0BB4 1 1 unit 41D
3 6.5 5.5 ... 8 21-1HA20 3RA2120-1HE24-0BB4 1 1 unit 41D
4 8.5 7 ... 10 21-1JA20 3RA2120-1JE24-0BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 21-1KA20 3RA2120-1KE24-0BB4 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA20 26-2BB40 3RA2120-4AE26-0BB4 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA20 27-2BB40 3RA2120-4BE27-0BB4 1 1 unit 41D
11 22 16 ... 22 21-4CA20 3RA2120-4CE27-0BB4 1 1 unit 41D
11 22 18 ... 25 21-4DA20 3RA2120-4DE27-0BB4 1 1 unit 41D
15 28 23 ... 28 21-4NA20 3RA2120-4NE27-0BB4 1 1 unit 41D
15 294) 27 ... 32 21-4EA20 3RA2120-4EE27-0BB4 1 1 unit 41D
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
S00 For load feeders for lower outputs, see this table at ToC
type of coordination "2". 1
1.5 3.6 3.5 ... 5 11-1FA20 15-2BB41 11-2AA00 3RA2110-1FE15-1BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA20 3RA2110-1GE15-1BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA20 3RA2110-1HE15-1BB4 1 1 unit 41D
4 8.5 7 ... 10 11-1JA20 16-2BB41 3RA2110-1JE16-1BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA20 17-2BB41 3RA2110-1KE17-1BB4 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA20 18-2BB40 3RA2110-4AE18-1BB4 1 1 unit 41D
1)
Push-in lugs, see "Accessories", page 8/52.
2)
Auxiliary switches, see "Accessories", page 8/45.
3) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
4)
Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using size S2.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/29
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA21 direct-on-line starters > for 60 mm busbars IE3 ready IE4 ready IE3/IE4 ready
AC-3e

■ Selection and ordering data


Direct-on-line starting Rated control supply voltage
50/60 Hz 230 V AC for S00, 50 Hz 230 V AC for S0 and S2
With screw terminals
• With busbar adapter
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches1) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
Contactor size S00: 1 NO,
3RA2110 3RA2120 Contactor sizes S0 and S2: 1 NO + 1 NC
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC2) of the inverse- Motor + Contactor + Link
time delayed starter module
Standard Motor overload Screw terminals
output current I release protector + Busbar
P (guide adapter
value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA10 15-1AP01 1921-1DA00 3RA2110-0BD15-1AP0 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA10 + 8US1251- 3RA2110-0CD15-1AP0 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA10 5DS10 3RA2110-0DD15-1AP0 1 1 unit 41D
8

0.09 0.3 0.28 ... 0.4 11-0EA10 3RA2110-0ED15-1AP0 1 1 unit 41D


0.12 0.4 0.35 ... 0.5 11-0FA10 3RA2110-0FD15-1AP0 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA10 3RA2110-0GD15-1AP0 1 1 unit 41D
0.18 0.6 0.55 ... 0.8 11-0HA10 3RA2110-0HD15-1AP0 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA10 3RA2110-0JD15-1AP0 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA10 3RA2110-0KD15-1AP0 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA10 3RA2110-1AD15-1AP0 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA10 3RA2110-1BD15-1AP0 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA10 3RA2110-1CD15-1AP0 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA10 3RA2110-1DD15-1AP0 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA10 3RA2110-1ED15-1AP0 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 11-1FA10 24-1AP00 2921-1AA00 3RA2120-1FD24-0AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 8US1251- 3RA2120-1GD24-0AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 5DT10 3RA2120-1HD24-0AP0 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 3RA2120-1JD24-0AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 3RA2120-1KD24-0AP0 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA10 26-1AP00 2921-1AA00 3RA2120-4AD26-0AP0 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA10 27-1AP00 + 8US1251- 3RA2120-4BD27-0AP0 1 1 unit 41D
11 22 16 ... 22 21-4CA10 5NT10 3RA2120-4CD27-0AP0 1 1 unit 41D
11 22 18 ... 25 21-4DA10 3RA2120-4DD27-0AP0 1 1 unit 41D
15 28 23 ... 28 21-4NA10 3RA2120-4ND27-0AP0 1 1 unit 41D
15 293) 27 ... 32 21-4EA10 3RA2120-4ED27-0AP0 1 1 unit 41D
S2 15 29 22 ... 32 32-4EA10 35-1AP00 2931-1AA00 Size S2 is only available for self-assembly.
18.5 35 28 ... 36 32-4PA10 + 8US1261-
18.5 35 32 ... 40 32-4UA10 6MT10
22 41 35 ... 45 32-4VA10 36-1AP00
22 41 42 ... 50 32-4WA10
30 55 49 ... 59 32-4XA10 37-1AP00
30 55 54 ... 65 32-4JA10
374) 66 62 ... 73 32-4KA10 38-1AP00
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
S00 For load feeders for lower outputs, see this table at ToC
type of coordination "2". 1
1.5 3.6 3.5 ... 5 11-1FA10 15-1AP01 1921-1DA00 3RA2110-1FD15-1AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 8US1251- 3RA2110-1GD15-1AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 5DS10 3RA2110-1HD15-1AP0 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 16-1AP01 3RA2110-1JD16-1AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 17-1AP01 3RA2110-1KD17-1AP0 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA10 18-1AP01 3RA2110-4AD18-1AP0 1 1 unit 41D
1) 3)
Auxiliary switches, see "Accessories", page 8/45. Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
2)
The actual starting and rated data of the motor to be protected must be For higher starting currents we recommend using size S2.
4)
considered when selecting the units. Maximum permissible current setting at motor starter protector 65 A, as the
maximum permissible current of the 3RA2931-1AA00 link module is 65 A.

* You can order this quantity or a multiple thereof.


8/30 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
AC-3e E3 ready IE4 ready IE3/IE4 ready 3RA21 direct-on-line starters > for 60 mm busbars

Direct-on-line starting Rated control supply voltage


50/60 Hz 230 V AC for S00, 50 Hz 230 V AC for S0
With spring-loaded terminals
• With busbar adapter
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches1) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
Contactor size S00: 1 NO,
3RA2110 3RA2120 Contactor size S0: 1 NO + 1 NC
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response SET, M)
400 V AC2) value of the
inverse-time
Standard Motor delayed Motor + Contactor + Link Spring-loaded
output current I overload starter module terminals
P (guide release protector + Busbar
value) adapter
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA29 ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA20 15-2AP01 11-2AA00 3RA2110-0BH15-1AP0 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA20 + 8US1251- 3RA2110-0CH15-1AP0 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA20 5DT11 3RA2110-0DH15-1AP0 1 1 unit 41D
0.09 0.3 0.28 ... 0.4 11-0EA20 3RA2110-0EH15-1AP0 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA20 3RA2110-0FH15-1AP0 1 1 unit 41D

8
0.18 0.6 0.45 ... 0.63 11-0GA20 3RA2110-0GH15-1AP0 1 1 unit 41D
0.18 0.6 0.55 ... 0.8 11-0HA20 3RA2110-0HH15-1AP0 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA20 3RA2110-0JH15-1AP0 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA20 3RA2110-0KH15-1AP0 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA20 3RA2110-1AH15-1AP0 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA20 3RA2110-1BH15-1AP0 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA20 3RA2110-1CH15-1AP0 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA20 3RA2110-1DH15-1AP0 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA20 3RA2110-1EH15-1AP0 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 21-1FA20 24-2AP00 21-2AA00 3RA2120-1FH24-0AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 21-1GA20 + 8US1251- 3RA2120-1GH24-0AP0 1 1 unit 41D
3 6.5 5.5 ... 8 21-1HA20 5NT113) 3RA2120-1HH24-0AP0 1 1 unit 41D
4 8.5 7 ... 10 21-1JA20 3RA2120-1JH24-0AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 21-1KA20 3RA2120-1KH24-0AP0 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA20 26-2AP00 3RA2120-4AH26-0AP0 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA20 27-2AP00 3RA2120-4BH27-0AP0 1 1 unit 41D
11 22 16 ... 22 21-4CA20 3RA2120-4CH27-0AP0 1 1 unit 41D
11 22 18 ... 25 21-4DA20 3RA2120-4DH27-0AP0 1 1 unit 41D
15 28 23 ... 28 21-4NA20 3RA2120-4NH27-0AP0 1 1 unit 41D
15 294) 27 ... 32 21-4EA20 3RA2120-4EH27-0AP0 1 1 unit 41D
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
S00 For load feeders for lower outputs, see this table at ToC
type of coordination "2". 1

1.5 3.6 3.5 ... 5 11-1FA20 15-2AP01 11-2AA00 3RA2110-1FH15-1AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA20 + 8US1251- 3RA2110-1GH15-1AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA20 5DT11 3RA2110-1HH15-1AP0 1 1 unit 41D
4 8.5 7 ... 10 11-1JA20 16-2AP01 3RA2110-1JH16-1AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA20 17-2AP01 3RA2110-1KH17-1AP0 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA20 18-2AP01 3RA2110-4AH18-1AP0 1 1 unit 41D
1)
Auxiliary switches, see "Accessories", page 8/45.
2) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
3)
A 3RA2911-1CA00 spacer for height compensation on AC contactors size
S0 with spring-loaded terminals is included in the scope of supply.
4)
Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using size S2.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/31
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA21 direct-on-line starters > for 60 mm busbars IE3 ready IE4 ready IE3/IE4 ready
AC-3e
Direct-on-line starting Rated control supply voltage 24 V DC
With screw terminals
• With busbar adapter
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches1) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
Contactor size S00: 1 NO,
3RA2110 3RA2120 Contactor sizes S0 and S2: 1 NO + 1 NC
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC2) of the inverse-
time delayed
Standard Motor overload Motor + Contactor + Link Screw terminals
output current I release starter module
P (guide protector + Busbar
value) adapter
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA10 15-1BB41 1921-1DA00 3RA2110-0BD15-1BB4 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA10 + 8US1251- 3RA2110-0CD15-1BB4 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA10 5DS10 3RA2110-0DD15-1BB4 1 1 unit 41D
0.09 0.3 0.28 ... 0.4 11-0EA10 3RA2110-0ED15-1BB4 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA10 3RA2110-0FD15-1BB4 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA10 3RA2110-0GD15-1BB4 1 1 unit 41D
8

0.18 0.6 0.55 ... 0.8 11-0HA10 3RA2110-0HD15-1BB4 1 1 unit 41D


0.25 0.85 0.7 ... 1 11-0JA10 3RA2110-0JD15-1BB4 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA10 3RA2110-0KD15-1BB4 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA10 3RA2110-1AD15-1BB4 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA10 3RA2110-1BD15-1BB4 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA10 3RA2110-1CD15-1BB4 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA10 3RA2110-1DD15-1BB4 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA10 3RA2110-1ED15-1BB4 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 11-1FA10 24-1BB40 2921-1BA00 3RA2120-1FD24-0BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 8US1251- 3RA2120-1GD24-0BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 5DT10 3RA2120-1HD24-0BB4 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 3RA2120-1JD24-0BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 3RA2120-1KD24-0BB4 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA10 26-1BB40 2921-1BA00 3RA2120-4AD26-0BB4 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA10 27-1BB40 + 8US1251- 3RA2120-4BD27-0BB4 1 1 unit 41D
11 22 16 ... 22 21-4CA10 5NT10 3RA2120-4CD27-0BB4 1 1 unit 41D
11 22 18 ... 25 21-4DA10 3RA2120-4DD27-0BB4 1 1 unit 41D
15 28 23 ... 28 21-4NA10 3RA2120-4ND27-0BB4 1 1 unit 41D
15 293) 27 ... 32 21-4EA10 3RA2120-4ED27-0BB4 1 1 unit 41D
S2 15 29 22 ... 32 32-4EA10 35-1NB30 2931-1AA00 Size S2 is only available for self-assembly.
18.5 35 28 ... 36 32-4PA10 + 8US1261-
18.5 35 32 ... 40 32-4UA10 6MT10
22 41 35 ... 45 32-4VA10 36-1NB30
22 41 42 ... 50 32-4WA10
30 55 49 ... 59 32-4XA10 37-1NB30
30 55 54 ... 65 32-4JA10
374) 66 62 ... 73 32-4KA10 38-1NB30
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
S00 For load feeders for lower outputs, see this table at ToC
type of coordination "2". 1
1.5 3.6 3.5 ... 5 11-1FA10 15-1BB41 1921-1DA00 3RA2110-1FD15-1BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 8US1251- 3RA2110-1GD15-1BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 5DS10 3RA2110-1HD15-1BB4 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 16-1BB41 3RA2110-1JD16-1BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 17-1BB41 3RA2110-1KD17-1BB4 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA10 18-1BB41 3RA2110-4AD18-1BB4 1 1 unit 41D
1) 4)
Auxiliary switches, see "Accessories", page 8/45. Maximum permissible current setting at motor starter protector 65 A, as the
2)
The actual starting and rated data of the motor to be protected must be maximum permissible current of the 3RA2931-1AA00 link module is 65 A.
considered when selecting the units.
3) Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using size S2.

* You can order this quantity or a multiple thereof.


8/32 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
AC-3e E3 ready IE4 ready IE3/IE4 ready 3RA21 direct-on-line starters > for 60 mm busbars

Direct-on-line starting Rated control supply voltage 24 V DC


With spring-loaded terminals
• With busbar adapter
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches1) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• Integrated auxiliary switches:
Contactor size S00: 1 NO,
Contactor size S0: 1 NO + 1 NC
3RA2110 3RA2120
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC2) of the inverse-
time delayed
Standard Motor overload Motor + Contactor + Link Spring-loaded
output current I release starter module terminals
P (guide protector + Busbar
value) adapter
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA29 ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA20 15-2BB41 11-2AA00 3RA2110-0BH15-1BB4 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA20 + 8US1251- 3RA2110-0CH15-1BB4 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA20 5DT11 3RA2110-0DH15-1BB4 1 1 unit 41D
0.09 0.3 0.28 ... 0.4 11-0EA20 3RA2110-0EH15-1BB4 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA20 3RA2110-0FH15-1BB4 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA20 3RA2110-0GH15-1BB4 1 1 unit 41D

8
0.18 0.6 0.55 ... 0.8 11-0HA20 3RA2110-0HH15-1BB4 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA20 3RA2110-0JH15-1BB4 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA20 3RA2110-0KH15-1BB4 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA20 3RA2110-1AH15-1BB4 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA20 3RA2110-1BH15-1BB4 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA20 3RA2110-1CH15-1BB4 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA20 3RA2110-1DH15-1BB4 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA20 3RA2110-1EH15-1BB4 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 21-1FA20 24-2BB40 21-2AA00 3RA2120-1FH24-0BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 21-1GA20 + 8US1251- 3RA2120-1GH24-0BB4 1 1 unit 41D
3 6.5 5.5 ... 8 21-1HA20 5NT11 3RA2120-1HH24-0BB4 1 1 unit 41D
4 8.5 7 ... 10 21-1JA20 3RA2120-1JH24-0BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 21-1KA20 3RA2120-1KH24-0BB4 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA20 26-2BB40 3RA2120-4AH26-0BB4 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA20 27-2BB40 3RA2120-4BH27-0BB4 1 1 unit 41D
11 22 16 ... 22 21-4CA20 3RA2120-4CH27-0BB4 1 1 unit 41D
11 22 18 ... 25 21-4DA20 3RA2120-4DH27-0BB4 1 1 unit 41D
15 28 23 ... 28 21-4NA20 3RA2120-4NH27-0BB4 1 1 unit 41D
15 293) 27 ... 32 21-4EA20 3RA2120-4EH27-0BB4 1 1 unit 41D
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
S00 For load feeders for lower outputs, see this table at ToC
type of coordination "2". 1
1.5 3.6 3.5 ... 5 11-1FA20 15-2BB41 11-2AA00 3RA2110-1FH15-1BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA20 + 8US1251- 3RA2110-1GH15-1BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA20 5DT11 3RA2110-1HH15-1BB4 1 1 unit 41D
4 8.5 7 ... 10 11-1JA20 16-2BB41 3RA2110-1JH16-1BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA20 17-2BB41 3RA2110-1KH17-1BB4 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA20 18-2BB40 3RA2110-4AH18-1BB4 1 1 unit 41D
1)
Auxiliary switches, see "Accessories", page 8/45.
2)
The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
3) Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using size S2.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/33
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA22 reversing starters > for DIN-rail mounting or screw fixing IE3 ready IE4 ready IE3/IE4 ready
AC-3e

■ Selection and ordering data


Reversing operation Rated control supply voltage
50/60 Hz 230 V AC for S00, 50 Hz 230 V AC for S0,
S2 and S3
With screw terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• Without DIN-rail adapter for size S00
• With 2 DIN-rail adapters for size S0 for mechanical
reinforcement (included in the scope of supply)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• With contactor sizes S0, S2 and S3, an integrated
3RA2210 3RA2220 NO contact is still available for free use.
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response SET, M)
400 V AC3) value of the
inverse-time
Standard Motor delayed Motor +2 + Link module Screw terminals
output current I overload starter contactors + RH mounting
P (guide release protector kit4)/wiring kit
value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA ToC
8

2
S00 0.06 0.2 0.14 ... 0.2 11-0BA10 15-1AP02 1921-1DA00 3RA2210-0BA15-2AP0 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA10 + 2913-2AA1 3RA2210-0CA15-2AP0 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA10 3RA2210-0DA15-2AP0 1 1 unit 41D
0.09 0.3 0.28 ... 0.4 11-0EA10 3RA2210-0EA15-2AP0 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA10 3RA2210-0FA15-2AP0 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA10 3RA2210-0GA15-2AP0 1 1 unit 41D
0.18 0.6 0.55 ... 0.8 11-0HA10 3RA2210-0HA15-2AP0 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA10 3RA2210-0JA15-2AP0 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA10 3RA2210-0KA15-2AP0 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA10 3RA2210-1AA15-2AP0 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA10 3RA2210-1BA15-2AP0 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA10 3RA2210-1CA15-2AP0 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA10 3RA2210-1DA15-2AP0 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA10 3RA2210-1EA15-2AP0 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 11-1FA10 24-1AP00 2921-1AA00 3RA2220-1FB24-0AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 2923-1BB1 3RA2220-1GB24-0AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2220-1HB24-0AP0 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 3RA2220-1JB24-0AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 3RA2220-1KB24-0AP0 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA10 26-1AP00 3RA2220-4AB26-0AP0 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA10 27-1AP00 3RA2220-4BB27-0AP0 1 1 unit 41D
11 22 16 ... 22 21-4CA10 3RA2220-4CB27-0AP0 1 1 unit 41D
11 22 18 ... 25 21-4DA10 3RA2220-4DB27-0AP0 1 1 unit 41D
15 28 23 ... 28 21-4NA10 3RA2220-4NB27-0AP0 1 1 unit 41D
15 295) 27 ... 32 21-4EA10 3RA2220-4EB27-0AP0 1 1 unit 41D
S2 15 29 22 ... 32 32-4EA10 35-1AP00 2931-1AA00 Size S2 is only available for self-assembly.
18.5 35 28 ... 36 32-4PA10 + 2933-1BB1
18.5 35 32 ... 40 32-4UA10
22 41 35 ... 45 32-4VA10 36-1AP00
22 41 42 ... 50 32-4WA10

30 55 49 ... 59 32-4XA10 37-1AP00


30 55 54 ... 65 32-4JA10
376) 66 62 ... 73 32-4KA10 38-1AP00
S3 Size S3 available on request Size S3 is only available for self-assembly
1) 5)
Push-in lugs, see "Accessories", page 8/52. Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
2)
Auxiliary switches, see "Accessories", page 8/45. For higher starting currents we recommend using size S2.
6)
3) The actual starting and rated data of the motor to be protected must be Maximum permissible current setting at motor starter protector 65 A, as the
considered when selecting the units. maximum permissible current of the 3RA2931-1AA00 link module is 65 A.
4)
RH = Mounting kit for reversing operation and DIN-rail mounting in
sizes S0 and S2.

* You can order this quantity or a multiple thereof.


8/34 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
AC-3e E3 ready IE4 ready IE3/IE4 ready 3RA22 reversing starters > for DIN-rail mounting or screw fixing

Reversing operation Rated control supply voltage


50/60 Hz 230 V AC for S00, 50 Hz 230 V AC for S0
With screw terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• Without DIN-rail adapter for size S00
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
3RA2210 modular system.
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC3) of the inverse-
time delayed
Standard Motor overload Motor +2 + Link module Screw terminals
output current I release starter contactors + RH mounting
P (guide protector kit4)/wiring kit
value)
Article No. Basic
price
kW A A per PU
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
3RV20 3RT20 3RA ToC
1
S00 Load feeders for lower outputs, see table for type of
coordination "2" on the previous page.
1.5 3.6 3.5 ... 5 11-1FA10 15-1AP02 1921-1DA00 3RA2210-1FA15-2AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 2913-2AA1 3RA2210-1GA15-2AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2210-1HA15-2AP0 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 16-1AP02 3RA2210-1JA16-2AP0 1 1 unit 41D

8
5.5 11.5 9 ... 12.5 11-1KA10 17-1AP02 3RA2210-1KA17-2AP0 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA10 18-1AP02 3RA2210-4AA18-2AP0 1 1 unit 41D

1) Push-in lugs, see "Accessories", page 8/52.


2)
Auxiliary switches, see "Accessories", page 8/45.
3)
The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
4) RH = Mounting kit for reversing operation and DIN-rail mounting in
sizes S0 and S2.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/35
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA22 reversing starters > for DIN-rail mounting or screw fixing IE3 ready IE4 ready IE3/IE4 ready
AC-3e
Reversing operation Rated control supply voltage
50/60 Hz 230 V AC for S00, 50 Hz 230 V AC for S0
With spring-loaded terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• Without DIN-rail adapter for size S00
• With two DIN-rail adapters for size S0 for mechanical
reinforcement (included in the scope of supply)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• With the contactor S0, an integrated NO contact is still
3RA2210 3RA2220 available for free use.
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC3) of the inverse-
Stan- Motor time delayed Motor +2 + Link module Spring-loaded
dard current I overload starter contactors + RH mounting terminals
output (guide release protector kit4)/wiring kit
P value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA29 ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA20 15-2AP02 11-2AA00 3RA2210-0BE15-2AP0 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA20 + 2913-2AA2 3RA2210-0CE15-2AP0 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA20 3RA2210-0DE15-2AP0 1 1 unit 41D
8

0.09 0.3 0.28 ... 0.4 11-0EA20 3RA2210-0EE15-2AP0 1 1 unit 41D


0.12 0.4 0.35 ... 0.5 11-0FA20 3RA2210-0FE15-2AP0 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA20 3RA2210-0GE15-2AP0 1 1 unit 41D
0.18 0.6 0.55 ... 0.8 11-0HA20 3RA2210-0HE15-2AP0 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA20 3RA2210-0JE15-2AP0 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA20 3RA2210-0KE15-2AP0 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA20 3RA2210-1AE15-2AP0 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA20 3RA2210-1BE15-2AP0 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA20 3RA2210-1CE15-2AP0 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA20 3RA2210-1DE15-2AP0 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA20 3RA2210-1EE15-2AP0 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 21-1FA20 24-2AP00 21-2AA00 3RA2220-1FF24-0AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 21-1GA20 + 2923-1BB25) 3RA2220-1GF24-0AP0 1 1 unit 41D
3 6.5 5.5 ... 8 21-1HA20 3RA2220-1HF24-0AP0 1 1 unit 41D
4 8.5 7 ... 10 21-1JA20 3RA2220-1JF24-0AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 21-1KA20 3RA2220-1KF24-0AP0 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA20 26-2AP00 3RA2220-4AF26-0AP0 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA20 27-2AP00 3RA2220-4BF27-0AP0 1 1 unit 41D
11 22 16 ... 22 21-4CA20 3RA2220-4CF27-0AP0 1 1 unit 41D
11 22 18 ... 25 21-4DA20 3RA2220-4DF27-0AP0 1 1 unit 41D
15 28 23 ... 28 21-4NA20 3RA2220-4NF27-0AP0 1 1 unit 41D
15 296) 27 ... 32 21-4EA20 3RA2220-4EF27-0AP0 1 1 unit 41D
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
S00 For load feeders for lower outputs, see this table at ToC
type of coordination "2". 1
1.5 3.6 3.5 ... 5 11-1FA20 15-2AP02 11-2AA00 3RA2210-1FE15-2AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA20 + 2913-2AA2 3RA2210-1GE15-2AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA20 3RA2210-1HE15-2AP0 1 1 unit 41D
4 8.5 7 ... 10 11-1JA20 16-2AP02 3RA2210-1JE16-2AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA20 17-2AP02 3RA2210-1KE17-2AP0 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA20 18-2AP02 3RA2210-4AE18-2AP0 1 1 unit 41D
1) 5)
Push-in lugs, see "Accessories", page 8/52. The RH mounting kit also includes the 3RA2911-1CA00 spacer for height
2)
Auxiliary switches, see "Accessories", page 8/45. compensation on AC contactors size S0 with spring-loaded terminals.
6)
3) The actual starting and rated data of the motor to be protected must be Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
considered when selecting the units. For higher starting currents we recommend using size S2.
4)
RH = Mounting kit for reversing operation and DIN-rail mounting in size S0.

* You can order this quantity or a multiple thereof.


8/36 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
AC-3e E3 ready IE4 ready IE3/IE4 ready 3RA22 reversing starters > for DIN-rail mounting or screw fixing

Reversing operation Rated control supply voltage 24 V DC


With screw terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• Without DIN-rail adapter for size S00
• With two DIN-rail adapters for size S0 for mechanical
reinforcement (included in the scope of supply)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• With contactor sizes S0, S2 and S3, an integrated
3RA2210 3RA2220 NO contact is still available for free use.
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response SET, M)
400 V AC3) value of the Motor +2 + Link module
inverse-time starter contactors + RH mounting
Standard Motor delayed Screw terminals
output current I overload protector kit4)/wiring kit
P (guide release
value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA10 15-1BB42 1921-1DA00 3RA2210-0BA15-2BB4 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA10 + 2913-2AA1 3RA2210-0CA15-2BB4 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA10 3RA2210-0DA15-2BB4 1 1 unit 41D

8
0.09 0.3 0.28 ... 0.4 11-0EA10 3RA2210-0EA15-2BB4 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA10 3RA2210-0FA15-2BB4 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA10 3RA2210-0GA15-2BB4 1 1 unit 41D
0.18 0.6 0.55 ... 0.8 11-0HA10 3RA2210-0HA15-2BB4 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA10 3RA2210-0JA15-2BB4 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA10 3RA2210-0KA15-2BB4 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA10 3RA2210-1AA15-2BB4 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA10 3RA2210-1BA15-2BB4 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA10 3RA2210-1CA15-2BB4 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA10 3RA2210-1DA15-2BB4 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA10 3RA2210-1EA15-2BB4 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 11-1FA10 24-1BB40 2921-1BA00 3RA2220-1FB24-0BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 2923-1BB1 3RA2220-1GB24-0BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2220-1HB24-0BB4 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 3RA2220-1JB24-0BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 3RA2220-1KB24-0BB4 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA10 26-1BB40 3RA2220-4AB26-0BB4 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA10 27-1BB40 3RA2220-4BB27-0BB4 1 1 unit 41D
11 22 16 ... 22 21-4CA10 3RA2220-4CB27-0BB4 1 1 unit 41D
11 22 18 ... 25 21-4DA10 3RA2220-4DB27-0BB4 1 1 unit 41D
15 28 23 ... 28 21-4NA10 3RA2220-4NB27-0BB4 1 1 unit 41D
15 295) 27 ... 32 21-4EA10 3RA2220-4EB27-0BB4 1 1 unit 41D
S2 15 29 22 ... 32 32-4EA10 35-1NB30 2931-1AA00 Size S2 is only available for self-assembly.
18.5 35 28 ... 36 32-4PA10 + 2933-1BB1
18.5 35 32 ... 40 32-4UA10
22 41 35 ... 45 32-4VA10 36-1NB30
22 41 42 ... 50 32-4WA10
30 55 49 ... 59 32-4XA10 37-1NB30
30 55 54 ... 65 32-4JA10
376) 66 62 ... 73 32-4KA10 38-1NB30
S3 Size S3 available on request Size S3 is only available for self-assembly.

1)
Push-in lugs, see "Accessories", page 8/52.
2)
Auxiliary switches, see "Accessories", page 8/45.
3) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
4)
RH = Mounting kit for reversing operation and DIN-rail mounting in
sizes S0 and S2.
5)
Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using size S2.
6) Maximum permissible current setting at motor starter protector 65 A, as the
maximum permissible current of the 3RA2931-1AA00 link module is 65 A.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/37
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA22 reversing starters > for DIN-rail mounting or screw fixing IE3 ready IE4 ready IE3/IE4 ready
AC-3e
Reversing operation Rated control supply voltage 24 V DC
With screw terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• Without DIN-rail adapter for size S00
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.

3RA2210
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response SET, M)
400 V AC3) value of the Motor +2 + Link module
inverse-time starter contactors + Wiring kit
Standard Motor delayed Screw terminals
output current I overload protector
P (guide release
value)
Article No. Basic
price
kW A A per PU
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
3RV20 3RT20 3RA ToC
1
S00 Load feeders for lower outputs, see table for type of
coordination "2" on the previous page.
1.5 3.6 3.5 ... 5 11-1FA10 15-1BB42 1921-1DA00 3RA2210-1FA15-2BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 2913-2AA1 3RA2210-1GA15-2BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2210-1HA15-2BB4 1 1 unit 41D
8

4 8.5 7 ... 10 11-1JA10 16-1BB42 3RA2210-1JA16-2BB4 1 1 unit 41D


5.5 11.5 9 ... 12.5 11-1KA10 17-1BB42 3RA2210-1KA17-2BB4 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA10 18-1BB42 3RA2210-4AA18-2BB4 1 1 unit 41D
1)
Push-in lugs, see "Accessories", page 8/52.
2)
Auxiliary switches, see "Accessories", page 8/45.
3) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.

* You can order this quantity or a multiple thereof.


8/38 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
AC-3e E3 ready IE4 ready IE3/IE4 ready 3RA22 reversing starters > for DIN-rail mounting or screw fixing

Reversing operation Rated control supply voltage 24 V DC


With spring-loaded terminals
• Screw fixing with two push-in lugs per load feeder
possible1)
• Without DIN-rail adapter for size S00
• With two DIN-rail adapters for size S0 for mechanical
reinforcement (included in the scope of supply)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches2) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• With the contactor S0, an integrated NO contact is still
3RA2210 3RA2220 available for free use.
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response SET, M)
400 V AC3) value of the
Stan- Motor inverse-time Motor +2 + Link module Spring-loaded
dard current I delayed starter contactors + RH mounting terminals
output (guide overload protector kit4)/wiring kit
P value) release
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA29 ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA20 15-2BB42 11-2AA00 3RA2210-0BE15-2BB4 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA20 + 2913-2AA2 3RA2210-0CE15-2BB4 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA20 3RA2210-0DE15-2BB4 1 1 unit 41D

8
0.09 0.3 0.28 ... 0.4 11-0EA20 3RA2210-0EE15-2BB4 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA20 3RA2210-0FE15-2BB4 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA20 3RA2210-0GE15-2BB4 1 1 unit 41D
0.18 0.6 0.55 ... 0.8 11-0HA20 3RA2210-0HE15-2BB4 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA20 3RA2210-0JE15-2BB4 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA20 3RA2210-0KE15-2BB4 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA20 3RA2210-1AE15-2BB4 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA20 3RA2210-1BE15-2BB4 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA20 3RA2210-1CE15-2BB4 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA20 3RA2210-1DE15-2BB4 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA20 3RA2210-1EE15-2BB4 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 21-1FA20 24-2BB40 21-2AA00 3RA2220-1FF24-0BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 21-1GA20 + 2923-1BB2 3RA2220-1GF24-0BB4 1 1 unit 41D
3 6.5 5.5 ... 8 21-1HA20 3RA2220-1HF24-0BB4 1 1 unit 41D
4 8.5 7 ... 10 21-1JA20 3RA2220-1JF24-0BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 21-1KA20 3RA2220-1KF24-0BB4 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA20 26-2BB40 3RA2220-4AF26-0BB4 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA20 27-2BB40 3RA2220-4BF27-0BB4 1 1 unit 41D
11 22 16 ... 22 21-4CA20 3RA2220-4CF27-0BB4 1 1 unit 41D
11 22 18 ... 25 21-4DA20 3RA2220-4DF27-0BB4 1 1 unit 41D
15 28 23 ... 28 21-4NA20 3RA2220-4NF27-0BB4 1 1 unit 41D
15 295) 27 ... 32 21-4EA20 3RA2220-4EF27-0BB4 1 1 unit 41D
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
S00 For load feeders for lower outputs, see this table at ToC
type of coordination "2". 1
1.5 3.6 3.5 ... 5 11-1FA20 15-2BB42 11-2AA00 3RA2210-1FE15-2BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA20 + 2913-2AA2 3RA2210-1GE15-2BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA20 3RA2210-1HE15-2BB4 1 1 unit 41D
4 8.5 7 ... 10 11-1JA20 16-2BB42 3RA2210-1JE16-2BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA20 17-2BB42 3RA2210-1KE17-2BB4 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA20 18-2BB42 3RA2210-4AE18-2BB4 1 1 unit 41D
1)
Push-in lugs, see "Accessories", page 8/52.
2) Auxiliary switches, see "Accessories", page 8/45.
3)
The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
4) RH = Mounting kit for reversing operation and DIN-rail mounting in size S0.
5)
Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using size S2.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/39
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA22 reversing starters > for 60 mm busbars IE3 ready IE4 ready IE3/IE4 ready
AC-3e

■ Selection and ordering data


Reversing operation Rated control supply voltage
50/60 Hz 230 V AC for S00, 50 Hz 230 V AC for S0 and S2
With screw terminals
• With busbar adapter and device holder (included in
the scope of supply)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches1) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• With contactor sizes S0 and S2, an integrated
3RA2210 3RA2220 NO contact is still available for free use.
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC2) of the inverse-
time delayed
Standard Motor overload Motor +2 + Link module Screw terminals
output current I release starter contactors + RS mount-
P (guide protector ing kit3)/
value) wiring kit
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA10 15-1AP02 1921-1DA00 3RA2210-0BD15-2AP0 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA10 + 2913-1DB1 3RA2210-0CD15-2AP0 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA10 3RA2210-0DD15-2AP0 1 1 unit 41D
8

0.09 0.3 0.28 ... 0.4 11-0EA10 3RA2210-0ED15-2AP0 1 1 unit 41D


0.12 0.4 0.35 ... 0.5 11-0FA10 3RA2210-0FD15-2AP0 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA10 3RA2210-0GD15-2AP0 1 1 unit 41D
0.18 0.6 0.55 ... 0.8 11-0HA10 3RA2210-0HD15-2AP0 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA10 3RA2210-0JD15-2AP0 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA10 3RA2210-0KD15-2AP0 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA10 3RA2210-1AD15-2AP0 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA10 3RA2210-1BD15-2AP0 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA10 3RA2210-1CD15-2AP0 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA10 3RA2210-1DD15-2AP0 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA10 3RA2210-1ED15-2AP0 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 11-1FA10 24-1AP00 2921-1AA00 3RA2220-1FD24-0AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 2923-1DB1 3RA2220-1GD24-0AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2220-1HD24-0AP0 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 3RA2220-1JD24-0AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 3RA2220-1KD24-0AP0 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA10 26-1AP00 3RA2220-4AD26-0AP0 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA10 27-1AP00 3RA2220-4BD27-0AP0 1 1 unit 41D
11 22 16 ... 22 21-4CA10 3RA2220-4CD27-0AP0 1 1 unit 41D
11 22 18 ... 25 21-4DA10 3RA2220-4DD27-0AP0 1 1 unit 41D
15 28 23 ... 28 21-4NA10 3RA2220-4ND27-0AP0 1 1 unit 41D
15 294) 27 ... 32 21-4EA10 3RA2220-4ED27-0AP0 1 1 unit 41D
S2 15 29 22 ... 32 32-4EA10 35-1AP00 2931-1AA00 Size S2 is only available for self-assembly.
18.5 35 28 ... 36 32-4PA10 + 2933-1DB1
18.5 35 32 ... 40 32-4UA10
22 41 35 ... 45 32-4VA10 36-1AP00
22 41 42 ... 50 32-4WA10
30 55 49 ... 59 32-4XA10 37-1AP00
30 55 54 ... 65 32-4JA10
375) 66 62 ... 73 32-4KA10 38-1AP00
1) Auxiliary switches, see "Accessories", page 8/45.
2)
The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
3)
RS = Mounting kit for reversing operation and busbar mounting.
4) Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using size S2.
5)
Maximum permissible current setting at motor starter protector 65 A, as the
maximum permissible current of the 3RA2931-1AA00 link module is 65 A.

* You can order this quantity or a multiple thereof.


8/40 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
AC-3e E3 ready IE4 ready IE3/IE4 ready 3RA22 reversing starters > for 60 mm busbars
.

Reversing operation Rated control supply voltage


50/60 Hz 230 V AC for S00
With screw terminals
• With busbar adapter and device holder (included in
the scope of supply)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches1) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
3RA2210
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC2) of the inverse-
time delayed
Standard Motor overload Motor +2 + Link module Screw terminals
output current I release starter contactors + RS mounting
P (guide protector kit3)/wiring kit
value)
Article No. Basic
price
kW A A per PU
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
3RV20 3RT20 3RA ToC
1
S00 Load feeders for lower outputs, see table for type of
coordination "2" on the previous page.
1.5 3.6 3.5 ... 5 11-1FA10 15-1AP02 1921-1DA00 3RA2210-1FD15-2AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 2913-1DB1 3RA2210-1GD15-2AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2210-1HD15-2AP0 1 1 unit 41D

8
4 8.5 7 ... 10 11-1JA10 16-1AP02 3RA2210-1JD16-2AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 17-1AP02 3RA2210-1KD17-2AP0 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA10 18-1AP02 3RA2210-4AD18-2AP0 1 1 unit 41D
1)
Auxiliary switches, see "Accessories", page 8/45.
2) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
3)
RS = Mounting kit for reversing operation and busbar mounting.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/41
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA22 reversing starters > for 60 mm busbars IE3 ready IE4 ready IE3/IE4 ready
AC-3e
Reversing operation Rated control supply voltage
50/60 Hz 230 V AC for S00, 50 Hz 230 V AC for S0
With spring-loaded terminals
• With busbar adapter and device holder (included in
the scope of supply)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches1) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• With the contactor S0, an integrated NO contact is still
3RA2210 3RA2220 available for free use.
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC2) of the inverse-
Stan- Motor time delayed Motor +2 + Link module Spring-loaded
dard current I overload starter contactors + RS mounting terminals
output (guide release protector kit3)/wiring kit
P value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA29 ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA20 15-2AP02 11-2AA00 3RA2210-0BH15-2AP0 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA20 + 13-1DB2 3RA2210-0CH15-2AP0 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA20 3RA2210-0DH15-2AP0 1 1 unit 41D
0.09 0.3 0.28 ... 0.4 11-0EA20 3RA2210-0EH15-2AP0 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA20 3RA2210-0FH15-2AP0 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA20 3RA2210-0GH15-2AP0 1 1 unit 41D
8

0.18 0.6 0.55 ... 0.8 11-0HA20 3RA2210-0HH15-2AP0 1 1 unit 41D


0.25 0.85 0.7 ... 1 11-0JA20 3RA2210-0JH15-2AP0 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA20 3RA2210-0KH15-2AP0 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA20 3RA2210-1AH15-2AP0 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA20 3RA2210-1BH15-2AP0 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA20 3RA2210-1CH15-2AP0 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA20 3RA2210-1DH15-2AP0 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA20 3RA2210-1EH15-2AP0 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 21-1FA20 24-2AP00 21-2AA00 3RA2220-1FH24-0AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 21-1GA20 + 23-1DB24) 3RA2220-1GH24-0AP0 1 1 unit 41D
3 6.5 5.5 ... 8 21-1HA20 3RA2220-1HH24-0AP0 1 1 unit 41D
4 8.5 7 ... 10 21-1JA20 3RA2220-1JH24-0AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 21-1KA20 3RA2220-1KH24-0AP0 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA20 26-2AP00 3RA2220-4AH26-0AP0 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA20 27-2AP00 3RA2220-4BH27-0AP0 1 1 unit 41D
11 22 16 ... 22 21-4CA20 3RA2220-4CH27-0AP0 1 1 unit 41D
11 22 18 ... 25 21-4DA20 3RA2220-4DH27-0AP0 1 1 unit 41D
15 28 23 ... 28 21-4NA20 3RA2220-4NH27-0AP0 1 1 unit 41D
15 295) 27 ... 32 21-4EA20 3RA2220-4EH27-0AP0 1 1 unit 41D
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
S00 For load feeders for lower outputs, see this table at ToC
type of coordination "2". 1
1.5 3.6 3.5 ... 5 11-1FA20 15-2AP02 11-2AA00 3RA2210-1FH15-2AP0 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA20 + 13-1DB2 3RA2210-1GH15-2AP0 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA20 3RA2210-1HH15-2AP0 1 1 unit 41D
4 8.5 7 ... 10 11-1JA20 16-2AP02 3RA2210-1JH16-2AP0 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA20 17-2AP02 3RA2210-1KH17-2AP0 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA20 18-2AP02 3RA2210-4AH18-2AP0 1 1 unit 41D
1) 4)
Auxiliary switches, see "Accessories", page 8/45. The RS mounting kit also includes the 3RA2911-1CA00 spacer for height
2)
The actual starting and rated data of the motor to be protected must be compensation on AC contactors size S0 with spring-loaded terminals.
5)
considered when selecting the units. Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
3) RS = Mounting kit for reversing operation and busbar mounting. For higher starting currents we recommend using size S2.

* You can order this quantity or a multiple thereof.


8/42 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
AC-3e E3 ready IE4 ready IE3/IE4 ready 3RA22 reversing starters > for 60 mm busbars

Reversing operation Rated control supply voltage 24 V DC


With screw terminals
• With busbar adapter and device holder (included in
the scope of supply)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches1) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• With contactor sizes S0 and S2, an integrated
3RA2210 3RA2220 NO contact is still available for free use.
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response SET, M)
400 V AC2) value of the Motor +2 + Link module
inverse-time starter contactors + RS mounting
Standard Motor delayed Screw terminals
output current I overload protector kit3)/wiring kit
P (guide release
value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA10 15-1BB42 1921-1DA00 3RA2210-0BD15-2BB4 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA10 + 2913-1DB1 3RA2210-0CD15-2BB4 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA10 3RA2210-0DD15-2BB4 1 1 unit 41D
0.09 0.3 0.28 ... 0.4 11-0EA10 3RA2210-0ED15-2BB4 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA10 3RA2210-0FD15-2BB4 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA10 3RA2210-0GD15-2BB4 1 1 unit 41D

8
0.18 0.6 0.55 ... 0.8 11-0HA10 3RA2210-0HD15-2BB4 1 1 unit 41D
0.25 0.85 0.7 ... 1 11-0JA10 3RA2210-0JD15-2BB4 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA10 3RA2210-0KD15-2BB4 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA10 3RA2210-1AD15-2BB4 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA10 3RA2210-1BD15-2BB4 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA10 3RA2210-1CD15-2BB4 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA10 3RA2210-1DD15-2BB4 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA10 3RA2210-1ED15-2BB4 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 11-1FA10 24-1BB40 2921-1BA00 3RA2220-1FD24-0BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 2923-1DB1 3RA2220-1GD24-0BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2220-1HD24-0BB4 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 3RA2220-1JD24-0BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 3RA2220-1KD24-0BB4 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA10 26-1BB40 3RA2220-4AD26-0BB4 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA10 27-1BB40 3RA2220-4BD27-0BB4 1 1 unit 41D
11 22 16 ... 22 21-4CA10 3RA2220-4CD27-0BB4 1 1 unit 41D
11 22 18 ... 25 21-4DA10 3RA2220-4DD27-0BB4 1 1 unit 41D
15 28 23 ... 28 21-4NA10 3RA2220-4ND27-0BB4 1 1 unit 41D
15 294) 27 ... 32 21-4EA10 3RA2220-4ED27-0BB4 1 1 unit 41D
S2 15 29 22 ... 32 32-4EA10 35-1NB30 2931-1AA00 Size S2 is only available for self-assembly.
18.5 35 28 ... 36 32-4PA10 + 2933-1DB1
18.5 35 32 ... 40 32-4UA10
22 41 35 ... 45 32-4VA10 36-1NB30
22 41 42 ... 50 32-4WA10
30 55 49 ... 59 32-4XA10 37-1NB30
30 55 54 ... 65 32-4JA10
375) 66 62 ... 73 32-4KA10 38-1NB30
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
S00 For load feeders for lower outputs, see this table at ToC
type of coordination "2". 1
1.5 3.6 3.5 ... 5 11-1FA10 15-1BB42 1921-1DA00 3RA2210-1FD15-2BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA10 + 2913-1DB1 3RA2210-1GD15-2BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA10 3RA2210-1HD15-2BB4 1 1 unit 41D
4 8.5 7 ... 10 11-1JA10 16-1BB42 3RA2210-1JD16-2BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA10 17-1BB42 3RA2210-1KD17-2BB4 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA10 18-1BB42 3RA2210-4AD18-2BB4 1 1 unit 41D
1) Auxiliary switches, see "Accessories", page 8/45. 4) Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
2)
The actual starting and rated data of the motor to be protected must be For higher starting currents we recommend using size S2.
5)
considered when selecting the units. Maximum permissible current setting at motor starter protector 65 A, as the
3)
RS = Mounting kit for reversing operation and busbar mounting. maximum permissible current of the 3RA2931-1AA00 link module is 65 A.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/43
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RA22 reversing starters > for 60 mm busbars IE3 ready IE4 ready IE3/IE4 ready
AC-3e
Reversing operation Rated control supply voltage 24 V DC
With spring-loaded terminals
• With busbar adapter and device holder (included in
the scope of supply)
• The motor starter protector and contactor are
mechanically and electrically connected by means
of the link module.
• Auxiliary switches1) on the motor starter protector
and the contactor can be easily fitted thanks to the
modular system.
• With the contactor S0, an integrated NO contact is still
available for free use.
3RA2210 3RA2220
Size Standard Adjustable Comprising the following Fuseless PU PS* PG
three-phase current single devices load feeder (UNIT,
motor 4-pole at response value SET, M)
400 V AC2) of the inverse-
Stan- Motor time delayed Motor +2 + Link module Spring-loaded
dard current I overload starter contactors + RS mounting terminals
output (guide release protector kit3)/wiring kit
P value)
Article No. Basic
price
kW A A per PU
Type of coordination "2" at Iq = 150 kA at 400 V
(also compatible with type of coordination "1")
3RV20 3RT20 3RA29 ToC
2
S00 0.06 0.2 0.14 ... 0.2 11-0BA20 15-2BB42 11-2AA00 3RA2210-0BH15-2BB4 1 1 unit 41D
0.06 0.2 0.18 ... 0.25 11-0CA20 + 13-1DB2 3RA2210-0CH15-2BB4 1 1 unit 41D
0.09 0.3 0.22 ... 0.32 11-0DA20 3RA2210-0DH15-2BB4 1 1 unit 41D
0.09 0.3 0.28 ... 0.4 11-0EA20 3RA2210-0EH15-2BB4 1 1 unit 41D
0.12 0.4 0.35 ... 0.5 11-0FA20 3RA2210-0FH15-2BB4 1 1 unit 41D
0.18 0.6 0.45 ... 0.63 11-0GA20 3RA2210-0GH15-2BB4 1 1 unit 41D
8

0.18 0.6 0.55 ... 0.8 11-0HA20 3RA2210-0HH15-2BB4 1 1 unit 41D


0.25 0.85 0.7 ... 1 11-0JA20 3RA2210-0JH15-2BB4 1 1 unit 41D
0.37 1.1 0.9 ... 1.25 11-0KA20 3RA2210-0KH15-2BB4 1 1 unit 41D
0.55 1.5 1.1 ... 1.6 11-1AA20 3RA2210-1AH15-2BB4 1 1 unit 41D
0.75 1.9 1.4 ... 2 11-1BA20 3RA2210-1BH15-2BB4 1 1 unit 41D
0.75 1.9 1.8 ... 2.5 11-1CA20 3RA2210-1CH15-2BB4 1 1 unit 41D
1.1 2.7 2.2 ... 3.2 11-1DA20 3RA2210-1DH15-2BB4 1 1 unit 41D
1.5 3.6 2.8 ... 4 11-1EA20 3RA2210-1EH15-2BB4 1 1 unit 41D
S0 1.5 3.6 3.5 ... 5 21-1FA20 24-2BB40 21-2AA00 3RA2220-1FH24-0BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 21-1GA20 + 23-1DB2 3RA2220-1GH24-0BB4 1 1 unit 41D
3 6.5 5.5 ... 8 21-1HA20 3RA2220-1HH24-0BB4 1 1 unit 41D
4 8.5 7 ... 10 21-1JA20 3RA2220-1JH24-0BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 21-1KA20 3RA2220-1KH24-0BB4 1 1 unit 41D
7.5 15.5 10 ... 16 21-4AA20 26-2BB40 3RA2220-4AH26-0BB4 1 1 unit 41D
7.5 15.5 13 ... 20 21-4BA20 27-2BB40 3RA2220-4BH27-0BB4 1 1 unit 41D
11 22 16 ... 22 21-4CA20 3RA2220-4CH27-0BB4 1 1 unit 41D
11 22 18 ... 25 21-4DA20 3RA2220-4DH27-0BB4 1 1 unit 41D
15 28 23 ... 28 21-4NA20 3RA2220-4NH27-0BB4 1 1 unit 41D
15 294) 27 ... 32 21-4EA20 3RA2220-4EH27-0BB4 1 1 unit 41D
Type of coordination "1" at Iq = 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
S00 For load feeders for lower outputs, see this table at ToC
type of coordination "2". 1
1.5 3.6 3.5 ... 5 11-1FA20 15-2BB42 11-2AA00 3RA2210-1FH15-2BB4 1 1 unit 41D
2.2 4.9 4.5 ... 6.3 11-1GA20 + 13-1DB2 3RA2210-1GH15-2BB4 1 1 unit 41D
3 6.5 5.5 ... 8 11-1HA20 3RA2210-1HH15-2BB4 1 1 unit 41D
4 8.5 7 ... 10 11-1JA20 16-2BB42 3RA2210-1JH16-2BB4 1 1 unit 41D
5.5 11.5 9 ... 12.5 11-1KA20 17-2BB42 3RA2210-1KH17-2BB4 1 1 unit 41D
7.5 15.5 10 ... 16 11-4AA20 18-2BB42 3RA2210-4AH18-2BB4 1 1 unit 41D
1) 3)
Auxiliary switches, see "Accessories", page 8/45. RS = Mounting kit for reversing operation and busbar mounting.
2) The actual starting and rated data of the motor to be protected must be 4) Suitable for use with IE3 and IE4 motors up to a starting current of 256 A.
considered when selecting the units. For higher starting currents we recommend using size S2.

* You can order this quantity or a multiple thereof.


8/44 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
Accessories

■ Overview
The accessories listed here are parts and add-ons for components for the customer assembly of fuseless load feeders.
the 3RA2 direct-on-line and reversing starters as well as

■ Selection and ordering data


Accessories for motor starter protectors
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41E

3RV2901-1E 3RV2901-2E 3RV2901-1A 3RV2901-2A


Version For motor Screw terminals Spring-loaded
starter terminals
protectors
Article No. Price Article No. Price
per PU per PU
Size
Auxiliary switches1)
Transverse auxiliary switches
For front mounting
1 CO S00 ... S3 3RV2901-1D --
1 NO + 1 NC 3RV2901-1E 3RV2901-2E
2 NO 3RV2901-1F 3RV2901-2F
Lateral auxiliary switches

8
For mounting on the left
1 NO + 1 NC S00 ... S3 3RV2901-1A 3RV2901-2A
1)
Each motor starter protector can be fitted with one transverse and one
lateral auxiliary switch. The lateral auxiliary switch with 2 NO + 2 NC is
used without a transverse auxiliary switch.

PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41E

3RV2902-1A.. 3RV2902-2A..

Rated control supply voltage Us For motor starter protectors Screw terminals Spring-loaded
terminals

AC AC AC AC/DC
50 Hz 60 Hz 50/60 Hz 50/60 Hz, Article No. Price Article No. Price
100% ON DC per PU per PU
period1) 5 s ON
period2)
V V V V Size
Auxiliary releases for motor starter protectors3)
Undervoltage releases
230 240 -- -- S00 ... S3 3RV2902-1AP0 3RV2902-2AP0
Shunt releases
-- -- 210 ... 240 190 ... 330 S00 ... S3 3RV2902-1DP0 3RV2902-2DP0
1)
The voltage range is valid for 100% (infinite) ON period. For the complete range of accessories for the motor starter
The response voltage lies at 0.9 of the lower limit of the voltage range. protectors, see page 7/47 onwards.
2) The voltage range is valid for 5 s ON period at 50/60 Hz AC and DC.
The response voltage lies at 0.85 of the lower limit of the voltage range.
3)
One auxiliary release can be mounted on the right per motor starter
protector (does not apply to 3RV21 motor starter protectors with overload
relay function).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/45
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
Accessories
Accessories for contactors
For contactors Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)
Size
Auxiliary switches for snapping onto the front of contactors
Screw terminals

Cable entry from below


S00 ... S3 1-pole
- 1 NO 3RH2911-1BA10 1 1 unit 41B
3RH2911-1BA.. - 1 NC 3RH2911-1BA01 1 1 unit 41B
S00 ... S3 2-pole
- 1 NO + 1 NC 3RH2911-1MA11 1 1 unit 41B
- 2 NO 3RH2911-1MA20 1 1 unit 41B

3RH2911-1MA..
Auxiliary switches for contactors, for lateral mounting
Screw terminals

S00 2 NC 3RH2911-1DA02 1 1 unit 41B


S00 1 NO + 1 NC 3RH2911-1DA11 1 1 unit 41B
S00 2 NO 3RH2911-1DA20 1 1 unit 41B
S0/S3 2 NC 3RH2921-1DA02 1 1 unit 41B
S0/S3 1 NO + 1 NC 3RH2921-1DA11 1 1 unit 41B
S0/S3 2 NO 3RH2921-1DA20 1 1 unit 41B
3RH2911-1DA..
Spring-loaded
terminals

S00 2 NC 3RH2911-2DA02 1 1 unit 41B


S00 1 NO + 1 NC 3RH2911-2DA11 1 1 unit 41B
S00 2 NO 3RH2911-2DA20 1 1 unit 41B
8

S0/S3 2 NC 3RH2921-2DA02 1 1 unit 41B


S0/S3 1 NO + 1 NC 3RH2921-2DA11 1 1 unit 41B
S0/S3 2 NO 3RH2921-2DA20 1 1 unit 41B
3RH2911-2DA..
Connection module (adapter and plug) for contactors with screw terminals
(can only be used for direct-on-line starters)
The connection module comprises an adapter and a motor Screw terminals
feeder connector.
Adapters
Ambient temperature Tu max. = 60 °C
S00 Rated operational current Ie 3RT1916-4RD01 1 1 unit 41B
at AC-3 and AC-3e/400 V: 20 A
3RT1926-4RD01
S0 Rated operational current Ie 3RT1926-4RD01 1 1 unit 41B
at AC-3 and AC-3e/400 V: 25 A
Motor feeder connector
S00, S0 -- 3RT1900-4RE01 1 1 unit 41B

3RT1900-4RE01

For the complete range of accessories for the 3RT contactors,


see page 3/69 onwards.

* You can order this quantity or a multiple thereof.


8/46 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
Accessories

For Version Rated control supply Article No.2) Price PU PS* PG


contac- voltage Us1) per PU (UNIT,
tors SET, M)
AC operation DC operation
Type V AC V DC
Surge suppressors without LED for contactors
(also for spring-loaded terminals)
Size S00
For plugging onto the front side of the contactors
(with or without auxiliary switches)
3RT2.1 Varistors 24 ... 48 24 ... 70 3RT2916-1BB00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2916-1BD00 1 1 unit 41B
3RT2.1 RC element 24 ... 48 24 ... 70 3RT2916-1CB00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2916-1CD00 1 1 unit 41B
3RT2.1 Interference -- 12 ... 250 3RT2916-1DG00 1 1 unit 41B
suppression diode
3RT2916-1B.00 3RT2.1 Diode assemblies -- 12 ... 250 3RT2916-1EH00 1 1 unit 41B
(diode and Zener
diode)
For DC operation
Size S0
For plugging onto the front side of the contactors
(before installing the auxiliary switch)
3RT2.2 Varistors2) 24 ... 48 24 ... 70 3RT2926-1BB00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2926-1BD00 1 1 unit 41B
3RT2.2 RC element 24 ... 48 24 ... 70 3RT2926-1CB00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2926-1CD00 1 1 unit 41B
3RT2.2 Diode assemblies -- 24 3RT2926-1ER00 1 1 unit 41B
For DC operation -- 30 ... 250 3RT2926-1ES00 1 1 unit 41B
3RT2926-1E.00
Size S2
For plugging onto the front side of the contactors

8
(before installing the auxiliary switch)
3RT2.3 Varistors2) 24 ... 48 -- 3RT2936-1BB00 1 1 unit 41B
127 ... 240 -- 3RT2936-1BD00 1 1 unit 41B
3RT2.3 RC element 24 ... 48 24 ... 70 3RT2936-1CB00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2936-1CD00 1 1 unit 41B
3RT2.3 Diode assemblies -- 24 3RT2936-1ER00 1 1 unit 41B
For DC operation -- 30 ... 250 3RT2936-1ES00 1 1 unit 41B
3RT2936-1B.00
Size S3
For plugging onto the front side of the contactors
(before installing the auxiliary switch)
3RT2.4 Varistors2) 24 ... 48 -- 3RT2936-1BB00 1 1 unit 41B
127 ... 240 -- 3RT2936-1BD00 1 1 unit 41B
3RT2.4 Diode assemblies -- 24 3RT2936-1ER00 1 1 unit 41B
For DC operation -- 30 ... 250 3RT2936-1ES00 1 1 unit 41B

3RT2936-1B.00
For plugging into the two recesses on the left of the connection
block for auxiliary switches and coils A1 and A2.
The connecting cables are wired to A1 and A2,
see also page 3/11.
3RT2.4 RC element 24 ... 48 24 ... 70 3RT2946-1CB00 1 1 unit 41B
127 ... 240 150 ... 250 3RT2946-1CD00 1 1 unit 41B

3RT2946-1C.00
1)
Can be used for AC operation for 50/60 Hz.
Please inquire about further voltages.
2)
The varistor is already integrated on the AC/DC contactors.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/47
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
Accessories
Accessories for the customer assembly of fuseless load feeders
For For Control circuit voltage Article No. Price PU PS* PG
motor starter contactors contactors per PU (UNIT,
protectors SET, M)
Size Size
Link modules from motor starter protector to contactor1)
Connection between motor starter protector and Screw terminals
contactor with screw terminals
Single-unit packaging
S00/S0 S00 AC/DC 3RA1921-1DA00 1 1 unit 41B
S00/S0 S0 AC 3RA2921-1AA00 1 1 unit 41B
S00/S0 S0 DC, AC/DC 3RA2921-1BA00 1 1 unit 41B
S2 S2 AC, DC, AC/DC 3RA2931-1AA00 1 1 unit 41B
S3 S3 AC, DC, AC/DC 3RA1941-1AA00 1 1 unit 41B
3RA2921-1AA00

3RA2931-1AA00
Multi-unit packaging
S00/S0 S00 AC/DC 3RA1921-1D 1 10 units 41B
S00/S0 S0 AC 3RA2921-1A 1 10 units 41B
S00/S0 S0 DC, AC/DC 3RA2921-1B 1 10 units 41B
S2 S2 AC, DC, AC/DC 3RA2931-1A 1 5 units 41B
S3 S3 AC, DC, AC/DC 3RA1941-1A 1 5 units 41B
3RA1941-1AA00
Connection between motor starter protector and Spring-loaded
contactor with spring-loaded terminals terminals
8

Single-unit packaging
S00 S00 AC/DC 3RA2911-2AA00 1 1 unit 41B
S0 S0 AC2), DC, AC/DC 3RA2921-2AA00 1 1 unit 41B
Multi-unit packaging
S00 S00 AC/DC 3RA2911-2A 1 10 units 41B
3RA2911-2AA00 S0 S0 AC2), DC, AC/DC 3RA2921-2A 1 10 units 41B
Hybrid link modules from motor starter protector to contactor3)
Connection between motor starter protector with screw
terminals and contactor with spring-loaded terminals
Single-unit packaging
S00 S00 AC/DC 3RA2911-2FA00 1 1 unit 41B
S0 S0 AC2), DC, AC/DC 3RA2921-2FA00 1 1 unit 41B

3RA2911-2FA00
Multi-unit packaging
S00 S00 AC/DC 3RA2911-2F 1 10 units 41B
S0 S0 AC2), DC, AC/DC 3RA2921-2F 1 10 units 41B

3RA2921-2FA00
1)
The link modules from motor starter protector to contactor cannot be used Note:
for the 3RV1011, 3RV2.21-4PA1., 3RV2.21-4FA1., 3RV2.31-4K.1.,
3RV2.31-4R.1., 3RV2.32-4K.1., 3RV2.32-4R.1., 3RV27 and 3RV28 motor Link modules can be used in
starter protectors/circuit breakers.
2) A spacer for height compensation on AC contactors, size S0, is optionally • Size S00 up to max. 16 A
available, see page 8/54. • Size S0 up to max. 32 A
3)
The hybrid link modules for motor starter protector to contactor cannot be • Size S2 up to max. 65 A
used for the 3RV1011, 3RV2.21-4PA1., 3RV2.21-4FA1., 3RV27 and 3RV28
motor starter protectors/circuit breakers. They are only suitable for Hybrid link modules can be used in
assembling direct-on-line starters.
• Size S00 up to max. 16 A
• Size S0 up to max. 32 A

* You can order this quantity or a multiple thereof.


8/48 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
Accessories

For For Article No. Price PU PS* PG


motor starter protectors 3RW30, 3RW40 soft starters; per PU (UNIT,
3RF34 solid-state contactors SET, M)
Size Size
Link modules for motor starter protector to soft starter1) and
motor starter protector to solid-state contactor1)
Connection between motor starter protector and soft Screw terminals
starter/solid-state contactor with screw terminals
Single-unit packaging
S00/S0 S00/S0 3RA2921-1BA00 1 1 unit 41B
S22) S2 3RA2931-1AA00 1 1 unit 41B
S33) S3 3RA1941-1AA00 1 1 unit 41B
3RA2921-1BA00 Multi-unit packaging
S00/S0 S00/S0 3RA2921-1B 1 10 units 41B
S22) S22) 3RA2931-1A 1 5 units 41B
S33) S33) 3RA1941-1A 1 5 units 41B
Connection between motor starter protector and soft Spring-loaded
starter with spring-loaded terminals terminals

Single-unit packaging
3RA2931-1AA00 S00 S00 3RA2911-2GA00 1 1 unit 41B
S0 S0 3RA2921-2GA00 1 1 unit 41B

3RA1941-1AA00

8
3RA2921-2GA00
1)
The link modules from motor starter protector to soft starter and motor Note:
starter protector to solid-state contactor cannot be used for the 3RV1011,
3RV2.21-4PA1., 3RV2.21-4FA1., 3RV2.31-4K.1., 3RV2.31-4R.1., Link modules can be used in
3RV2.32-4K.1., 3RV2.32-4R.1., 3RV27 and 3RV28 motor starter
protectors/circuit breakers. • Size S00 up to max. 16 A
2) • Size S0 up to max. 32 A
To assemble the feeder between a motor starter protector and a soft starter
in size S2, the 3RA2932-1CA00 DIN-rail adapter must be used.
3) It is only permitted to assemble the feeder between the motor starter • Size S2 up to max. 65 A
protector and the soft starter in size S3 on a mounting plate.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/49
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
Accessories
PU (UNIT, SET, M) = 1
PS* = 1 unit (unless otherwise specified)
PG = 41B

3RA2923-2AA1 3RA2933-2AA1 3RA2923-2AA2


For Size Version Screw terminals Spring-loaded
contactors terminals

Article No. Price Article No. Price


Type per PU per PU
Assembly kits for reversing contactor assemblies
for making 3-pole contactor assemblies
3RT201 S00-S00 The assembly kit contains:
Mechanical interlock,
two connecting clips for two contactors,
wiring modules on the top and bottom
• For main, auxiliary and control circuits 3RA2913-2AA1 3RA2913-2AA2
3RT202 S0-S0 The assembly kit contains:
Mechanical interlock,
two connecting clips for two contactors,
wiring modules on the top and bottom
• For main, auxiliary and control circuits1) 3RA2923-2AA1 --
• Only for main circuit2) -- 3RA2923-2AA2
3RT203 S2-S2 The assembly kit contains:
Two connectors for two contactors,
8

wiring modules on the top and bottom


(3RA2934-2B mechanical interlock must be ordered
separately, see page 3/108)
• For main and auxiliary circuits 3RA2933-2AA1 --
• Only for main circuit3) -- 3RA2933-2AA2
3RT204 S3-S3 The assembly kit contains:
Two connectors for two contactors,
wiring modules on the top and bottom
(3RA2934-2B mechanical interlock must be ordered
separately, see page 3/108)
• For main and auxiliary circuits 3RA2943-2AA1 --
• Only for main circuit3) -- 3RA2943-2AA2
1)
Use of the 3RA2923-2AA1 assembly kit in conjunction with the
3RT202.-.....-3MA0 contactors is limited because the auxiliary switches
in the basic unit are not allowed to be used on account of the permanently
mounted auxiliary switch.
2) Version in size S0 with spring-loaded terminals:
Only the wiring modules for the main circuit are included.
No connecting clips are included for the auxiliary and control circuit.
3)
Version in sizes S2 and S3 with spring-loaded terminals in the auxiliary and
control circuits: Only the wiring modules for the main circuit are included.
A cable set is included for the auxiliary circuit.

* You can order this quantity or a multiple thereof.


8/50 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
Accessories

For Version Article No. Price PU PS* PG


contactors per PU (UNIT,
SET, M)
Size
Safety main circuit connectors for two contactors
For switching two contactors in series Screw terminals

S00 3RA2916-1A 1 1 unit 41B


S0 3RA2926-1A 1 1 unit 41B
S2 3RA2936-1A 1 1 unit 41B

3RA2916-1A

For motor For con- Version Article No. Price PU PS* PG


starter tactors per PU (UNIT,
protectors SET, M)
Mounting rails for mounting contactors for the customer assembly of 3RA21
load feeders with busbar adapters for 60 mm systems
For the discrete configuration of direct-
on-line starters a further mounting rail is
needed for the contactor in addition to
the mounting rail for the motor starter
protector existing on the busbar adapter.
-- S0 For pushing onto the device adapter, 8US1998-7CB45 1 10 units 14O
including fixing screws

8US1998-7CB45
DIN-rail adapters
For mechanical fixing of motor starter
protector and contactor; for snapping
onto DIN rail or for screw fixing

8
S00, S00 S00, S00 Short, single-unit packaging 3RA2922-1BA00 1 1 unit 41B
S00, S00 S00, S00 Short, multi-unit packaging 3RA2922-1B 1 5 units 41B
S00, S0 S00, S0 Single-unit packaging 3RA2922-1AA00 1 1 unit 41B
S00, S0 S00, S0 Multi-unit packaging 3RA2922-1A 1 5 units 41B
S2 S2 Single-unit packaging 3RA2932-1AA00 1 1 unit 41B
S2 S2 Multi-unit packaging 3RA2932-1A 1 5 units 41B
3RA2922-1AA00
S3 S3 Single-unit packaging 3RA2942-1AA00 1 1 unit 41B
S3 S3 Multi-unit packaging 3RA2942-1A 1 5 units 41B
For mechanical fixing of motor starter
protector and soft starter; for snapping
onto DIN rail or for screw fixing
S2 S2 Single-unit packaging 3RA2932-1CA00 1 1 unit 41B

3RA2932-1CA00
Side modules for DIN-rail adapters
S00 ... S3 S00 ... S3 For DIN-rail adapters 3RA2902-1B 1 10 units 41B
10 mm wide, 96 mm long:
for widening DIN-rail adapters when
using lateral auxiliary switches,
2 units required

3RA2902-1B
Connecting wedges
For mechanical linking of DIN-rail adapters 8US1998-1AA00 100 100 units 14O
(2 units required for mounting)

8US1998-1AA00

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/51
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
Accessories

For motor For con- Version Article No. Price PU PS* PG


starter tactors per PU (UNIT,
protectors SET, M)
RH mounting kits for reversing operation and DIN-rail mounting
RH mounting kits for screw terminals Screw terminals

S0 S0 Comprising: 3RA2923-1BB1 1 1 unit 41B


• Wiring kit for main and auxiliary circuit
• Two DIN-rail adapters
• Two connecting wedges
• Mechanical interlocks
• Two connecting clips for two contactors
• Fixing accessories
Link modules must be ordered
separately.

3RA2923-1BB1
S2 S2 Comprising: 3RA2933-1BB1 1 1 unit 41B
• Wiring kit for main and auxiliary circuit
• Two DIN-rail adapters
• Two side modules
• Four connecting wedges
• Mechanical interlocks
• Two connectors for two contactors
• Fixing accessories
Link modules must be ordered
separately.
3RA2933-1BB1
S3 S3 Comprising: 3RA2943-1BB1 1 1 unit 41B
• Wiring kit for main and auxiliary circuit
• Two DIN-rail adapters
• Three side modules
• Six connecting wedges
• Mechanical interlocks
• Two connectors for two contactors
• Fixing accessories
8

Link modules must be ordered


3RA2943-1BB1 separately.
RH mounting kits for spring-loaded terminals Spring-loaded
terminals

S0 S0 Comprising: 3RA2923-1BB2 1 1 unit 41B


• Wiring kit for main and auxiliary circuit
• Two DIN-rail adapters
• Two connecting wedges
• Mechanical interlocks
• Two connecting clips for two contactors
• Two spacers
• Fixing accessories
Link modules must be ordered
separately.
3RA2923-1BB2
Push-in lugs for screw fixing
S00, S0 -- For screw fixing of motor starter 3RV2928-0B 100 10 units 41E
protector (of the load feeder) on
mounting plates; 2 units are required
for each motor starter protector

3RV2928-0B

For overview graphics for RH mounting kits,


see page 8/13 onwards.

* You can order this quantity or a multiple thereof.


8/52 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
Accessories
Busbar adapters

8US1251-5DS10 8US1251-5DT11 8US1250-5AS10 8US1250-5AT10


For Rated Connect- Adapter Adapter Rated voltage Article No. Price PU PS* PG
load feeders current ing cable length width per PU (UNIT,
SET, M)
Size A AWG mm mm V
Busbar adapters for 60 mm systems
For copper busbars according to DIN 46433
Width: 12 mm and 30 mm
Thickness: 5 mm and 10 mm
and for T and double-T special profiles
• For load feeders with screw terminals Screw terminals

S00/S0 25 12 200 45 690 8US1251-5DS10 1 1 unit 14O


S00 (motor starter 25 12 260 45 690 8US1251-5DT10 1 1 unit 14O
protector)/
S0 (contactor)
S0 32 10 200 45 690 8US1251-5NS10 1 1 unit 14O
S0 32 10 260 45 690 8US1251-5NT10 1 1 unit 14O
S2 80 4 260 55 690 8US1261-6MT10 1 1 unit 14O
S21) 80 4 260 118 690 8US1211-6MT10 1 1 unit 14O
• For load feeders with spring-loaded terminals Spring-loaded
terminals

8
S00 25 12 200 45 690 8US1251-5DS11 1 1 unit 14O
S00/S0 25 12 260 45 690 8US1251-5DT11 1 1 unit 14O
S0 32 10 200 45 690 8US1251-5NS11 1 1 unit 14O
S0 32 10 260 45 690 8US1251-5NT11 1 1 unit 14O
Accessories2)
Device holders -- -- 200 45 -- 8US1250-5AS10 1 1 unit 14O
For lateral attachment -- -- 260 45 -- 8US1250-5AT10 1 1 unit 14O
to busbar adapters
Side modules -- -- 200 9 -- 8US1998-2BJ10 1 10 units 14O
For widening
busbar adapters
Vibration and shock kits
For high vibration and
shock loads
S2 -- -- -- -- -- 8US1998-1DA10 1 1 unit 14O
1) For the assembly of load feeders for reversing starters comprising a motor
starter protector and two contactors.
2)
Additional mounting rails for busbar adapters, see page 8/51.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/53
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
Accessories

For motor For Version Article No. Price PU PS* PG


starter contac- per PU (UNIT,
protectors tors SET, M)
Size Size
RS mounting kits for reversing operation
and 60 mm busbar systems
RS mounting kits for screw terminals Screw terminals

S00, S0 S00 Comprising: 3RA2913-1DB1 1 1 unit 41B


S0 S0 • Wiring kit for main and auxiliary 3RA2923-1DB1 1 1 unit 41B
S00 S0 circuit 3RA2923-1EB1 1 1 unit 41B
• Busbar adapters
• Device holders
• Two connecting wedges
• Mechanical interlocks
• Two connecting clips for two
contactors
• Fixing accessories
Link modules must be ordered
3RA2913-1DB1 separately.
S2 S2 Comprising: 3RA2933-1DB1 1 1 unit 41B
• Wiring kit for main and auxiliary
circuit
• Busbar adapters
• Mechanical interlocks
• Two connectors for two contactors
• Fixing accessories
Link modules must be ordered
separately.

3RA2933-1DB1
RS mounting kits for spring-loaded terminals Spring-loaded
terminals
S00 S00 Comprising: 3RA2913-1DB2 1 1 unit 41B
S0 S0 • Wiring kit for main and auxiliary 3RA2923-1DB2 1 1 unit 41B
8

circuit
• Busbar adapters
• Device holders
• Two connecting wedges
• Mechanical interlocks
• Two connectors for two contactors
• Two spacers
(for size S0 only)
• Fixing accessories
3RA2913-1DB2 Link modules must be ordered
separately.

For overview graphics for RS mounting kits,


see page 8/16 onwards.

For motor For Version Article No. Price PU PS* PG


starter contac- per PU (UNIT,
protectors tors SET, M)
Size Size
Connecting wedges
For mechanical linking of busbar adapters and device 8US1998-1AA10 1 50 units 14O
holders

8US1998-1AA10
Spacers
For height compensation on AC contactors size S0 with Spring-loaded
spring-loaded terminals terminals
S0 S0 Single-unit packaging 3RA2911-1CA00 1 1 unit 41B
S0 S0 Multi-unit packaging 3RA2911-1C 1 5 units 41B

3RA2911-1CA00

* You can order this quantity or a multiple thereof.


8/54 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
Accessories

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Tools for opening spring-loaded terminals


Screwdriver Spring-loaded
For all SIRIUS devices with spring-loaded terminals terminals
Length, approx. 200 mm, 3RA2908-1A 1 1 unit 41B
3.0 mm x 0.5 mm,
titanium gray/black,
3RA2908-1A partially insulated
Blank labels
Unit labeling plates1) 3RT2900-1SB20 100 340 units 41B
For SIRIUS devices
20 mm x 7 mm,
titanium gray
IC01_00181

3RT2900-1SB20
Manuals
Configuration Manual for load feeders
see
https://support.industry.siemens.com/cs/ww/en/view/39714188.
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/55
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA2 load feeders
3RV29 infeed system for load feeders

■ Overview
Types of infeed for 3RA2 fuseless load feeders 8US busbar adapters for 60 mm systems
On the whole four different power infeed possibilities The load feeders are mounted directly with the aid of busbar
are available: adapters on busbar systems with 60 mm center-to-center
• Parallel wiring clearance in order to save space and to reduce infeed times
and costs.
• Use of 3-phase busbars (combination with SIRIUS motor
starter protectors and contactors possible) The busbar adapters for busbar systems with 60 mm center-to-
• 8US busbar adapters center clearance are suitable for copper busbars with a width of
12 to 30 mm. The busbars can be 4 to 5 mm or 10 mm thick.
• SIRIUS 3RV29 infeed systems
The feeders are snapped onto the adapter and connected on
Insulated 3-phase busbar system the line side. This prepared unit is then plugged directly onto the
3-phase busbar systems provide an easy, time-saving and busbar system, and is thus connected both mechanically and
clearly arranged means of feeding 3RA2 load feeders with electrically at the same time.
screw terminals. Different versions are available for sizes S00 "Selection and ordering data", see page 8/53.
and S0 and can also be used for the various different types of
motor starter protectors.
The busbars are suitable for between two and five feeders.
However, any kind of extension is possible by clamping
the connection tags of an additional busbar (rotated 180°)
underneath the terminals of the respective last motor starter
protector.
A combination of feeders of different sizes is possible with sizes
S00 and S0. Connecting pieces are available for this purpose.
The motor starter protectors are supplied by appropriate infeed
terminals.

3RV2925-5AB

3RV1915-1CB
8

NSB0_02080a
3RV2915-5B SIRIUS load feeders with busbar adapters snapped onto busbars
NSB0_02079c

SIRIUS 3RV29 infeed system


The 3RV29 infeed system is a convenient means of energy
supply and distribution for a group of several motor starter
protectors or complete load feeders with screw or spring-loaded
terminals up to size S0.
3RV1915-6AB
The system is based on a basic module complete with a lateral
incoming unit (3-phase busbar with infeed) which has two slots.
SIRIUS 3-phase busbar system size S00/S0
Expansion modules are available for extending the system
The 3-phase busbar systems are finger-safe. They are designed (3-phase busbars for system expansion).
for any short-circuit stress which can occur at the output side of
connected motor starter protectors. 3RV29 infeed system, see page 7/67.
The 3-phase busbar systems can also be used to construct
"Starters (Type E)" of size S0 or S2 according to UL/CSA.
However, special infeed terminals must be used for this
purpose, see page 7/52.

8/56 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
General data

■ Overview
3RA6 fuseless compact starters and infeed system for 3RA6
More information
Homepage, see www.siemens.com/sirius-compact-starters
Industry Mall, see www.siemens.com/product?3RA6
Online configurator, see www.siemens.com/sirius/configurators

Very high operational reliability


The high short-circuit breaking capacity and defined shutdown
when the end of service life is reached mean that the
SIRIUS compact starter achieves a very high level of operational
reliability that would otherwise have only been possible with
considerable additional outlay. This sets it apart from devices
with similar functionality.
Safe disconnection
The auxiliary switches (NC contacts) of the 3RA6 compact
starters are designed as mirror contacts. This enables their use
for safe disconnection, e.g. EMERGENCY STOP up to SIL 1
(IEC 62061) or PL c (ISO 13849-1) or, if used in conjunction with
an additional infeed contactor, up to SIL 3 (IEC 62061) or PL e
(ISO 13849-1).
3RA62 reversing starter Communication link through AS-Interface
Integrated functionality For communication link through AS-Interface there is an
The SIRIUS 3RA6 compact starters are a generation of special AS-i add-on module available in several versions for mounting
load feeders with the integrated functionality of a motor starter instead of the control circuit terminals on the SIRIUS compact
protector, contactor and electronic overload relay. In addition, starter.
various functions of optional mountable accessories (e.g. auxiliary The design of the AS-i add-on module permits a group of up
switches, surge suppressors) are already integrated in the to 62 feeders with a total of four cables to be connected to
SIRIUS compact starter. the control system. This reduces wiring work considerably

8
compared to the parallel wiring method.
Communication link through IO-Link
Up to four compact starters in IO-Link version (reversing
and direct-on-line starters) can be connected together and
conveniently linked to the IO-Link master through a standardized
IO-Link connection.
The IO-Link connection enables a high density of information
in the local range.
For details regarding the communication link using IO-Link,
see page 2/88 onwards.
The diagnostics data of the process collected by the 3RA6
compact starter, e.g. short circuit, end of service life, limit
position, etc., are not only indicated on the compact starter itself
but also transmitted to the higher-level control system through
IO-Link.
Thanks to the optionally available operator panel, which can be
installed in the control cabinet door, it is easy to control the 3RA6
compact starters with IO-Link from the control cabinet door.
Permanent wiring/easy replacement
3RA6 compact starters with the integrated functionality of a motor starter Using the SIRIUS infeed system for 3RA6 (see page 8/76),
protector, contactor and electronic overload relay it is possible to carry out the wiring in advance without
Applications a compact starter having to be connected.

SIRIUS compact starters can be used wherever standard A compact starter is very easily replaced simply by pulling it out
three-phase motors or resistive loads up to 32 A of the device without disconnecting the wiring.
(approx. 15 kW/400 V) are directly started or switched. Even with screw fixing or mounting on a DIN rail there is no need
The compact starters are not suitable for the protection of to disconnect any wiring (on account of the removable main and
DC loads. control circuit terminals) in order to replace a compact starter.

Approvals according to IEC, UL, CSA and CCC standards have


been issued for the compact starters.

Siemens IC 10 · 2023 8/57


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
General data
Consistent solution from the infeed to the motor feeder SIRIUS 3RA6 compact starters
The SIRIUS feeder system for 3RA6 with integral PE bar is SIRIUS 3RA6 compact starters are universal motor feeders
available as a user-friendly system for supplying summation according to IEC 60947-6-2. As control and protective switching
current up to 100 A with a maximum conductor cross-section of devices (CPS) they can connect, convey and disconnect the
70 mm² and for direct connection of the motor cable without thermal, dynamic and electrical loads from short-circuit
additional intermediate terminals. currents up to Iq = 53 kA, i.e. they are practically weld-free.
They combine the functions of a motor starter protector,
Screw and spring-loaded terminals a contactor and an electronic overload relay in one enclosure.
The SIRIUS compact starters and the infeed system for 3RA6 are The versions available are the 45-mm-wide direct-on-line
available with screw and spring-loaded terminals. starters and the 90-mm-wide reversing starters.
The reversing starter version comes with not only an internal
Screw terminals electrical interlock but also with a mechanical interlock to
prevent simultaneous actuation of both directions of rotation.
Spring-loaded terminals The compact starters have isolating features in accordance
with IEC 60947-2 and can be used as disconnector units (main
The terminals are indicated in the corresponding control switch according to EN 60204 or VDE 0113). Isolation
tables by the symbols shown on orange backgrounds. is effected by moving the handle into the "OFF" position;
disconnection by means of the control contacts is not enough.
System configurator for engineering 3RA6 fuseless compact starters are available in five current
A free system configurator is available to reduce further the setting ranges. The 3RA61 and 3RA62 have two control voltage
amount of engineering work for selecting the required compact ranges (AC/DC), and the 3RA64 and 3RA65 have one control
starters and matching infeed. voltage range (DC):

Use of load feeders in conjunction with IE3 and IE4 motors Current At 400 V AC for Rated control supply voltage for
setting three-phase
range motors 3RA61, 3RA62 3RA64, 3RA65
Note: compact starters compact starters
Standard for IO-Link
For the use of SIRIUS 3RA6 compact starters in conjunction output P
with highly efficient IE3 and IE4 motors, please observe the
information on dimensioning and configuring, see A kW V AC/DC V DC
Application Manual. 0.1 ... 0.4 0.09 24 24
For more information, see page 1/8. 0.32 ... 1.25 0.37 110 ... 240
8

Types of infeed for the 3RA6 fuseless compact starters 1 ... 4 1.5
3 ... 12 5.5
On the whole four different infeed possibilities are available:
• Parallel wiring 8 ... 32 15

• Use of 3-phase busbars (combination with SIRIUS motor Notes:


starter protectors and SIRIUS contactors possible)
The 3RA2 load feeders can be used for fuseless load feeders
• 8US busbar adapters > 32 A up to 65 A. Load feeders in size S3 up to 100 A are
• SIRIUS infeed system for 3RA6 (see page 8/76) available for customer assembly (see also page 8/5).
To comply with the clearance and creepage distances required The SENTRON 3VL circuit breakers and the SIRIUS 3RT
according to UL 508, there are the following infeed possibilities: contactors can be used for fuseless load feeders > 100 A.
Type of infeed Infeed terminal Type Operating conditions
(according to UL 508,
Type E) The SIRIUS 3RA6 compact starters are suitable for use in any
climate. They are intended for use in enclosed rooms in which
Parallel wiring Terminal block for 3RV2928-1H no severe operating conditions (such as dust, caustic vapors,
"Self-Protected
Combination Motor
hazardous gases) prevail. Suitable covers must be provided for
Controller (Type E)" installation in dusty and damp locations.
3-phase busbars 3-phase infeed terminal 3RV2925-5EB The permissible ambient temperature during operation is
for constructing -20 to +60 °C. The rated short-circuit current ICS according
"Starters (Type E)", to IEC 60947-6-2 is 53 kA at 400 V.
UL 508
Note:
Infeed system for 3RA6 Infeed on left, 3RA6813-8AB
50/70 mm2, screw (screw terminals), The maximum permissible short-circuit currents of the device
terminal with 3 sockets,
outgoing terminal
3RA6813-8AC versions for the various line system configurations and voltages
(spring-loaded are available upon request from Technical Support:
with screw/spring- terminals)
loaded terminals www.siemens.com/support-request
incl. PE bar

8/58 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
General data
Overload tripping times More components of the 3RA6
The tripping time in the event of overload can be set on the Apart from the control supply voltage, "Overload" (1 CO)
device to normal starting conditions (CLASS 10) and to heavy and "Short circuit/Function fault" (1 NO) signaling contacts are
starting conditions (CLASS 20). As the breaker mechanism still already integrated into the 3RA61/3RA62 – and lockable via two
remains closed after an overload, resetting is possible by either 6-pole removable control circuit terminals. The 3RA61 has two
local Manual RESET or Auto RESET1) after three minutes auxiliary contacts (1 NO + 1 NC) for displaying the position
cooling time. of the main contacts. Unlike the 3RA61 direct-on-line starter,
the 3RA62 reversing starter has one auxiliary contact (1 NO)
With Auto RESET, there is no need to open the control cabinet. per direction of rotation per main contact.
Diagnostics options A slot for an optional auxiliary switch (either 2 NO, 2 NC or
The compact starter provides the following diagnostics options: 1 NO + 1 NC) is available for the 3RA61 and 3RA64 direct-on-
• With LEDs line starters. For the 3RA62 and 3RA65 reversing starters,
- Connection to the control voltage two slots are available (auxiliary switches, see "Accessories",
- Position of the main contacts page 8/70).
• With mechanical display Force-guided operation of the auxiliary contacts
- Tripping due to overload Force-guided operation between individual auxiliary circuits
- Tripping due to short circuit exists for the compact starter in the version as a direct-on-line
- Tripping due to malfunction (end of service life reached starter for parallel wiring (3RA61) between the auxiliary circuits
because of worn switching contacts or a worn switching of the NC contacts (NC 21-22) and the NO contacts (NO 13-14)
mechanism or faults in the control electronics) in the basic unit.
These states can also be evaluated in the higher-level control In addition, the optional auxiliary switch offers force-guided
system: contacts in the 3RA6913-1A version, each with one normally
closed contact and one normally open contact.
• With parallel wiring using the integrated auxiliary and
signaling switches of the compact starter Configurator
• With AS-Interface or IO-Link in even greater detail using
the respective communications interface
Four complement versions for 3RA61 and 3RA62 compact
starters
• For DIN-rail mounting or screw fixing:
basic version including one pair of main circuit terminals

8
and one pair of control circuit terminals
• For DIN-rail mounting or screw fixing when using the
AS-i add-on module:
without control circuit terminals because the AS-i add-on
module is plugged on instead
• For use in the infeed system for 3RA6:
without main circuit terminals because they are supplied with
the infeed system and the expansion modules
• For use in the infeed system for 3RA6 and AS-i add-on Configurator
module: without terminal complement (also for reordering
when replacing the compact starter) Advantages:
• Simple usage – from individual compact starters or also with
The control circuit terminals are always required by the compact corresponding infeed system and AS-i connection
starters for IO-Link; the main circuit terminals depend on the use
of the infeed system. • In the final configuration, you will be presented with additional
1) technical information such as CAD data and product data
The Auto RESET function is not available for versions 3RA6120-.B/.C with
a rated current of 1.25 A and 3RA6250-.B/-.C with a rated current of 4 A. sheets as well as characteristic curves, operating instructions,
The reset can be alternatively carried out by disconnecting the supply manuals, etc.
voltage A1/A2 via the NC contacts 95/96 (overload signaling contact).
The Auto RESET function is provided with this circuitry. See www.siemens.com/sirius/configurators

Siemens IC 10 · 2023 8/59


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
General data
Article number scheme

Product versions Article number


Compact starters 3RA6 @ @ @ – @ @ @ @ @
Product function Direct-on-line starter 1 2 0 For motor standard output 0.09 ... 15 kW1)
Reversing starter 2 5 0 For motor standard output 0.09 ... 15 kW1)
Direct-on-line starter 4 0 0 For motor standard output 0.09 ... 15 kW1)
for IO-Link
Reversing starter for IO-Link 5 0 0 For motor standard output 0.09 ... 15 kW1)
Infeed system 8
Accessories 9
• Auxiliary switches 1 @
• Terminals 2 @
• IO-Link accessories 3 @
• Fixing elements 4 @
• Control kit 5 @
Connection methods No terminals 0
Screw terminals 1
Spring-loaded terminals 2
Setting range 0.1 ... 0.4 A A
0.32 ... 1.25 A B
1 ... 4 A C
3 ... 12 A D
8 ... 32 A E
Rated control supply 24 V DC B 4 For direct-on-line/reversing starters for IO-Link
voltage 24 V AC/DC B 3 For direct-on-line/reversing starters
110 ... 240 V AC/DC P 3 For direct-on-line/reversing starters
Terminal None 0 Without main and control circuit terminals
complement versions 1/1 2 With 1 pair of main circuit and 1 pair of control circuit terminals
0/1 3 Without main circuit terminals, with 1 pair of control circuit terminals
8

1/0 4 With 1 pair of main circuit terminals, without control circuit terminals
Special versions
Example 3RA6 1 2 0 – 0 A B 3 0
1) Standard three-phase motor, basis 4-pole at 400 V AC; the actual starting
and rated data of the motor to be protected must be considered when
selecting the units.
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

■ Benefits
Product advantages
The SIRIUS 3RA6 compact starters offer a number of benefits: • Quick replacement of devices thanks to removable terminals
• Compact design saves space in the control cabinet with spring-loaded and screw terminals in the main and
control circuit
• Little planning and assembly work and far less wiring thanks
to a single complete unit with one article number • Efficient power distribution through the related SIRIUS infeed
system for 3RA6
• Low variance and therefore low stock levels, with two wide
voltage ranges and five wide setting ranges for the rated • Direct connection of the motor feeder cable to the
current SIRIUS infeed system for 3RA6 thanks to integrated PE bar
• High plant availability through integrated functionalities such • Connecting and looping through of incoming feeders up to
as prevention of main contact welding and disconnection at a cross-section of 70 mm²
end of service life • When using the infeed system for 3RA6, possibility of directly
• Enhanced productivity through automatic device RESET1) connecting the motor cable without intermediate terminals
in case of overload and differentiated detection of overload • Integration in Totally Integrated Automation thanks to
and short circuit the optional connection to AS-Interface or IO-Link
• Easy checking of the wiring and testing of the motor direction The SIRIUS 3RA6 compact starters create the basis for
prior to startup thanks to optional control kits high-availability and future-proof machine concepts.
1) The Auto RESET function is not available for versions 3RA6120-.B/.C with
a rated current of 1.25 A and 3RA6250-.B/-.C with a rated current of 4 A.
The reset can be alternatively carried out by disconnecting the supply
voltage A1/A2 via the NC contacts 95/96 (overload signaling contact).
The Auto RESET function is provided with this circuitry.

8/60 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
General data

■ Technical specifications
More information
Industry Mall, see www.siemens.com/product?3RA6 Notes on security:
System Manual, see In order to protect plants, systems, machines and networks against cyber
http://support.industry.siemens.com/cs/ww/en/view/27865747. threats, it is necessary to implement – and continuously maintain – a holistic,
state-of-the-art industrial security concept. Siemens products and solutions
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16301/faq represent only one component of such a concept.
For more information about the subject of Industrial Security, see
www.siemens.com/industrialsecurity.

Type 3RA61 3RA62 3RA64 3RA65


Mechanics and environment
Mounting dimensions (W x H x D)
• Screw terminals mm 45 x 170 x 165 90 x 170 x 165 45 x 170 x 165 90 x 170 x 165
• Spring-loaded terminals mm 45 x 191 x 165 90 x 191 x 165 45 x 191 x 165 90 x 191 x 165
H

W D

Depth from DIN rail mm 160


Permissible ambient temperature
• During operation °C -20 ... +70, restriction as from 60 depending on design
(permissible operational current, see the
following section "Electrical specifications")
• During storage °C -55 ... +80
• During transport °C -55 ... +80
Permissible mounting position

NSB0_00649a
22,5° 22,5°
90° 90°

Shock resistance (sine-wave pulse) a = 60 m/s² = 6 g with 10 ms; for every 3 shocks in all axes
Vibratory load f = 4 ... 5.8 Hz; d = 15 mm; f = 5.8 ... 500 Hz; a = 20 m/s2; 10 cycles
Degree of protection IP on the front According to IEC 60529 IP20

8
Touch protection on the front According to IEC 60529 Finger-safe for vertical touching from the front
Installation altitude m Up to 2 000 above sea level without restriction
Relative air humidity % 10 ... 90
Pollution degree 3
Electrical specifications
Device standard IEC 60947-6-2
Maximum rated operational voltage Ue V 690
V 400 at 3RA6250-.E... and 3RA6500-.E...
(Reversing starter 32 A versions)
Rated frequency Hz 50/60
Rated insulation voltage Ui V 690
(pollution degree 3)
Rated impulse withstand voltage Uimp kV 6
Rated current Ie1) 0.1 ... 0.4 A A 0.4
and setting range for overload release 0.32 ... 1.25 A A 1.25
1 ... 4 A A 4
3 ... 12 A A 12
8 ... 32 A A 32
Permissible operational current of the compact starter2)
When several compact starters are mounted side-by-side in the infeed system
for 3RA6 (for more details on the various design versions,
see System Manual)
• For a control cabinet inside temperature of +40 °C % 100
• For a control cabinet inside temperature of +60 °C % 80
• For a control cabinet inside temperature of +70 °C % 60
Trip class (CLASS) According to IEC 60947-4-1, 10/20
EN 60947-4-1
(VDE 0660 Part 102)
Overload function 1:4
Ratio of lower to upper current mark
Rated service short-circuit breaking kA 53
capacity ICS at 50/60 Hz, 400 V AC
Rated service short-circuit breaking kA 1.5
capacity ICSIT at 50/60 Hz 400/690 V AC
in IT systems
1) 2)
For the use of 3RA6 compact starters in conjunction with highly efficient Details about installation conditions and the use of the compact starters,
IE3 and IE4 motors, please observe the information on dimensioning and and particularly about the derating of the rated current, can be found in the
configuring, see Application Manual. System Manual.

Siemens IC 10 · 2023 8/61


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
General data

Type 3RA61 3RA62 3RA64 3RA65


Electrical specifications (continued)
Power loss Pv max of all main conducting paths 0.4 A mW 10
Dependent on rated current Ie 1.25 A mW 100
(upper setting range) 4A W 1
12 A W 1.8
32 A W 5.4
Max. switching frequency AC-41 1/h 750
AC-43 1/h 250
AC-44 1/h 15
No-load switching frequency 1/h 3 600 3 600, depending on the IO-Link
communication time
Isolating features of the compact starter According to IEC 60947-3 ✓
Isolation is assured only by moving the handle into the "OFF" position.
Main and EMERGENCY OFF switch According to IEC 60204 ✓
characteristics of the compact starter
and accessories
Protective separation According to IEC 60947-2
Control circuit to auxiliary circuit
• Horizontal DIN rail V Up to 400
• Other mounting position V Up to 250
Auxiliary circuit to auxiliary circuit
• Horizontal DIN rail V Up to 400
• Other mounting position V Up to 250
Main circuit to auxiliary circuit
• Any mounting position V Up to 400
EMC interference immunity According to IEC 60947-1 Corresponds to degree of severity 3
Conducted interference BURST according to
IEC 61000-4-4
• In the main circuit kV 4 4
• In the auxiliary circuit kV 3 2
Conducted interference SURGE according to
IEC 61000-4-5
• In the main circuit
8

- Conductor - Ground kV 4 2
- Conductor - Conductor kV 2 1
• In the auxiliary circuit
- Conductor - Ground kV 2 0.51)
- Conductor - Conductor kV 1 0.51)
Auxiliary switches
• Integrated
- Position of the main contacts 1 NO + 1 NC 2 NO 1 NO + 1 NC 2 NO
- Overload/short circuit and malfunction signal 1 CO/1 NO
• Expandable
- Position of the main contacts 2 NO, 2 NC, 1 NO, 1 NC
Surge suppressors Integrated (varistor)
Electromagnetic operating mechanisms
Control voltage V 24 AC/DC 24 DC
V 110 ... 240 AC/DC --
Frequency At AC Hz 50/60 ( 5%)
Operating range 0.7 ... 1.25 Us 0.85 ... 1.2 Us
No-load switching frequency 1/h 3 600
Line protection At 10 kA mm² 2.5
At 50 kA mm² 4
Shock resistance
• Breaker mechanism OFF g 25
• Breaker mechanism ON g 15
Normal switching duty
Making capacity 12 x In
Breaking capacity 10 x In
Switching capacity dependent on Up to 12 A kW 5.5
rated current Up to 32 A kW 15
Endurance in operating cycles
• Electrical endurance At Ie = 0.9 x In and 400 V 3 ... 2x 3 000 000 2 x 1 500 000
10 000 000 3 ... 10 000 000
✓ Function available
1)
To maintain maximum interference immunity in a harsh electromagnetic
environment, additional overvoltage protection should be provided in the
control circuit. The 5SD7432-4 plug-in surge arrester with remote signaling,
for instance, is suitable, see Catalog LV 10.

8/62 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
General data

Type 3RA6120-.@B3., 3RA6250-.@B3. 3RA6120-.EB3., 3RA6250-.EB3.


@ = A, B, C or D
Rated operational current  12 A Rated operational current 32 A
Rated control supply voltage V 24 AC 24 DC 24 AC 24 DC
Inrush peak current A 0.59 0.47 0.59 0.47
Hold current A 0.13 0.12 0.17 0.14
Closed W 2.8 2.9 3.5 3.1
Operating times, typical
• On ms < 160 < 140 < 160 < 140
• Off ms < 35 < 35 < 30 < 30
Type 3RA6120-.@P3., 3RA6250-.@P3. 3RA6120-.EP3., 3RA6250-.EP3.
@ = A, B, C or D
Rated operational current  12 A Rated operational current 32 A
Rated control supply voltage V 110 AC 240 AC 110 DC 240 DC 110 AC 240 AC 110 DC 240 DC
Inrush peak current A 0.24 0.40 0.17 0.29 0.24 0.40 0.17 0.29
Hold current A 0.06 0.08 0.03 0.02 0.06 0.07 0.04 0.03
Closed W 3.8 6 3.1 5.1 3.7 5.2 3.4 5.8
Operating times, typical
• On ms < 160 < 140 < 150 < 140 < 160 < 140 < 150 < 140
• Off ms < 50 < 80 < 50 < 70 < 40 < 60 < 40 < 60
Type 3RA6400-.@B4., 3RA6500-.@B4. 3RA6400-.EB4., 3RA6500-.EB4.
@ = A, B, C or D
Rated operational current  12 A Rated operational current 32 A
Rated control supply voltage V 24 DC 24 DC
Inrush peak current A 0.39 0.53
Hold current A 0.13 0.15
Closed W 2.9 3.4
Operating times, typical1)
• On ms < 140 < 140

8
• Off ms < 35 < 30
1)
Plus IO-Link communication.

Type 3RA6
Control circuit
Rated operational voltage
• External auxiliary switch V 400/690
• Internal auxiliary switch V 400/690
• Short-circuit signaling switch V 400
• Overload signaling switch V 400
Switching capacity
• External auxiliary switch AC-15
• Up to Ue = 230 V A 6
• Up to Ue = 400 V A 3
• Up to Ue = 289/500 V A 2
• Up to Ue = 400/690 V A 1
DC-13
• Up to Ue = 24 V A 6
• Up to Ue = 60 V A 0.9
• Up to Ue = 125 V A 0.55
• Up to Ue = 250 V A 0.27
• Internal auxiliary switch AC-15
• Up to Ue = 230 V A 6
• Up to Ue = 400 V A 3
• Up to Ue = 289/500 V A 2
• Up to Ue = 400/690 V A 1
DC-13
• Up to Ue = 24 V A 10
• Up to Ue = 60 V A 2
• Up to Ue = 125 V A 1
• Up to Ue = 250 V A 0.27
• Up to Ue = 480 V A 0.1
• Signaling switch AC-15
• Up to Ue = 230 V A 3
• Up to Ue = 400 V A 1
DC-13
• Up to Ue = 24 V A 2
• Up to Ue = 250 V A 0.11

Siemens IC 10 · 2023 8/63


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
General data

Type 3RA61, 3RA62 3RA64, 3RA65


External auxiliary switches, internal auxiliary switches
Endurance in operating cycles
• Mechanical endurance 10 000 000 3 000 000
• Electrical endurance AC-15, 230 V
• Up to 6 A 200 000
• Up to 3 A 500 000
• Up to 1 A 2 000 000
• Up to 0.3 A 10 000 000
DC-13, 24 V
• Up to 6 A 30 000
• Up to 3 A 100 000
• Up to 0.5 A 2 000 000
• Up to 0.2 A 10 000 000
DC-13, 110 V
• Up to 1 A 40 000
• Up to 0.55 A 100 000
• Up to 0.3 A 300 000
• Up to 0.1 A 2 000 000
• Up to 0.04 A 10 000 000
DC-13, 220 V
• Up to 0.3 A 110 000
• Up to 0.1 A 650 000
• Up to 0.05 A 2 000 000
• Up to 0.018 A 10 000 000
Contact reliability At 17 V and 5 mA Oper- 1 incorrect switching operation per 100 000 000
ating
cycles
Short-circuit protection
• Short-circuit current IK  1.1 kA Fuse links, A 10
operational class gG
- NEOZED type 5SE
- DIAZED type 5SB
- LV HRC type 3NA
• Short-circuit current IK < 400 A Miniature circuit breaker up to A 10
230 V with C characteristic
Signaling switches
8

Endurance in operating cycles


• Mechanical endurance 20 000
• Electrical endurance AC-15 At 230 V and 3 A 6 050
Contact reliability At 17 V and 5 mA Oper- 1 incorrect switching operation per 100 000 000
ating
cycles
Short-circuit protection
• Short-circuit current IK  1.1 kA Fuse links, A 6
operational class gG
- NEOZED type 5SE
- DIAZED type 5SB
- LV HRC type 3NA
• Short-circuit current IK < 400 A Miniature circuit breaker up to A 6
230 V with C characteristic
Overload (short-circuit current IK  1.1 kA) Fuse links, A 4
operational class gG
- NEOZED type 5SE
- DIAZED type 5SB
- LV HRC type 3NA

8/64 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
IE3 ready IE4 ready IE3/IE4 ready 3RA61, 3RA62 compact starters > 3RA61 direct-on-line starters

■ Selection and ordering data


Direct-on-line starting Width 45 mm

Rated short-circuit current ICS = 53 kA at 400 V

A set of 3RA6940-0A adapters is required for screw fixing.

PU (UNIT, SET, M) = 1
PS* = 1 unit
NSB0_01946 PG = 42F

3RA6120-1CB32 3RA6120-2EB32
Standard three-phase Setting range Instantaneous Article No. Price Article No. Price
motor 4-pole at 400 V AC1) for electronic electronic release per PU per PU
Standard output P overload release

kW A A
For use in the infeed system for 3RA6 and
with AS-i add-on module or as a replacement device,
without main and control circuit terminals
0.09 0.1 ... 0.4 56 3RA6120-0A@30 --
0.37 0.32 ... 1.25 56 3RA6120-0B@30 --
1.5 1 ... 4 56 3RA6120-0C@30 --
5.5 3 ... 12 168 3RA6120-0D@30 --
15 8 ... 32 448 3RA6120-0E@30 --

8
Screw terminals Spring-loaded
terminals
For DIN-rail mounting or screw fixing,
with 1 pair of main circuit terminals and 1 pair of control circuit terminals
0.09 0.1 ... 0.4 56 3RA6120-1A@32 3RA6120-2A@32
0.37 0.32 ... 1.25 56 3RA6120-1B@32 3RA6120-2B@32
1.5 1 ... 4 56 3RA6120-1C@32 3RA6120-2C@32
5.5 3 ... 12 168 3RA6120-1D@32 3RA6120-2D@32
15 8 ... 32 448 3RA6120-1E@32 3RA6120-2E@32
For use in the infeed system for 3RA6,
without main circuit terminals, with 1 pair of control circuit terminals
0.09 0.1 ... 0.4 56 3RA6120-1A@33 3RA6120-2A@33
0.37 0.32 ... 1.25 56 3RA6120-1B@33 3RA6120-2B@33
1.5 1 ... 4 56 3RA6120-1C@33 3RA6120-2C@33
5.5 3 ... 12 168 3RA6120-1D@33 3RA6120-2D@33
15 8 ... 32 448 3RA6120-1E@33 3RA6120-2E@33
Article No. supplements for rated control supply voltage
• 24 V AC/DC B B
• 110 ... 240 V AC/DC P P
For DIN-rail mounting or screw fixing,
for use with AS-i add-on module
with 1 pair of main circuit terminals, without control circuit terminals
Rated control supply voltage 24 V AC/DC
0.09 0.1 ... 0.4 56 3RA6120-1AB34 3RA6120-2AB34
0.37 0.32 ... 1.25 56 3RA6120-1BB34 3RA6120-2BB34
1.5 1 ... 4 56 3RA6120-1CB34 3RA6120-2CB34
5.5 3 ... 12 168 3RA6120-1DB34 3RA6120-2DB34
15 8 ... 32 448 3RA6120-1EB34 3RA6120-2EB34
1) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/65
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
3RA61, 3RA62 compact starters > 3RA62 reversing starters IE3 ready IE4 ready IE3/IE4 ready

■ Selection and ordering data


Reversing operation Width 90 mm

Rated short-circuit current ICS = 53 kA at 400 V

Two sets of 3RA6940-0A adapters are required for screw


fixing.

NSB0_01947
PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 42F
3RA6250-1CP32 3RA6250-2DP32
Standard three-phase Setting range for electronic Instantaneous Article No. Price Article No. Price
motor 4-pole at 400 V AC1) overload release electronic release per PU per PU
Standard output P

kW A A
For use in the infeed system for 3RA6,
and with AS-i add-on module or as a replacement device,
without main and control circuit terminals
0.09 0.1 ... 0.4 56 3RA6250-0A@30 --
0.37 0.32 ... 1.25 56 3RA6250-0B@30 --
1.5 1 ... 4 56 3RA6250-0C@30 --
5.5 3 ... 12 168 3RA6250-0D@30 --
15 8 ... 32 448 3RA6250-0E@30 --

Screw terminals Spring-loaded


terminals
8

For DIN-rail mounting or screw fixing,


with 1 pair of main circuit terminals and 1 pair of control circuit terminals
0.09 0.1 ... 0.4 56 3RA6250-1A@32 3RA6250-2A@32
0.37 0.32 ... 1.25 56 3RA6250-1B@32 3RA6250-2B@32
1.5 1 ... 4 56 3RA6250-1C@32 3RA6250-2C@32
5.5 3 ... 12 168 3RA6250-1D@32 3RA6250-2D@32
15 8 ... 32 448 3RA6250-1E@32 3RA6250-2E@32
For use in the infeed system for 3RA6,
without main circuit terminals, with 1 pair of control circuit terminals
0.09 0.1 ... 0.4 56 3RA6250-1A@33 3RA6250-2A@33
0.37 0.32 ... 1.25 56 3RA6250-1B@33 3RA6250-2B@33
1.5 1 ... 4 56 3RA6250-1C@33 3RA6250-2C@33
5.5 3 ... 12 168 3RA6250-1D@33 3RA6250-2D@33
15 8 ... 32 448 3RA6250-1E@33 3RA6250-2E@33
Article No. supplements for rated control supply voltage
• 24 V AC/DC B B
• 110 ... 240 V AC/DC P P
For DIN-rail mounting or screw fixing,
for use with AS-i add-on module
with 1 pair of main circuit terminals, without control circuit terminals
Rated control supply voltage 24 V AC/DC
0.09 0.1 ... 0.4 56 3RA6250-1AB34 3RA6250-2AB34
0.37 0.32 ... 1.25 56 3RA6250-1BB34 3RA6250-2BB34
1.5 1 ... 4 56 3RA6250-1CB34 3RA6250-2CB34
5.5 3 ... 12 168 3RA6250-1DB34 3RA6250-2DB34
15 8 ... 32 448 3RA6250-1EB34 3RA6250-2EB34
1) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.

* You can order this quantity or a multiple thereof.


8/66 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
IE3 ready IE4 ready IE3/IE4 ready 3RA64, 3RA65 compact starters for IO-Link > 3RA64 direct-on-line starters

■ Selection and ordering data


Direct-on-line starting
Rated control supply voltage 24 V DC

Width 45 mm

Rated short-circuit current ICS = 53 kA at 400 V

A set of 3RA6940-0A adapters is required for screw fixing.


NSB0_01946
PU (UNIT, SET, M) = 1
PS* = 1 unit
3RA64 with 3RA6911-1A PG = 42F
auxiliary switch
Standard three-phase Setting range for electronic Instantaneous electronic Article No. Price Article No. Price
motor 4-pole at 400 V AC1) overload release release per PU per PU
Standard output P
Screw terminals Spring-loaded
terminals
kW A A
For DIN-rail mounting or screw fixing,
with 1 pair of main circuit terminals and 1 pair of control circuit terminals
0.09 0.1 ... 0.4 56 3RA6400-1AB42 3RA6400-2AB42
0.37 0.32 ... 1.25 56 3RA6400-1BB42 3RA6400-2BB42
1.5 1 ... 4 56 3RA6400-1CB42 3RA6400-2CB42
5.5 3 ... 12 168 3RA6400-1DB42 3RA6400-2DB42
15 8 ... 32 448 3RA6400-1EB42 3RA6400-2EB42
For use in the infeed system for 3RA6,
without main circuit terminals, with 1 pair of control circuit terminals
0.09 0.1 ... 0.4 56 3RA6400-1AB43 3RA6400-2AB43
0.37 0.32 ... 1.25 56 3RA6400-1BB43 3RA6400-2BB43

8
1.5 1 ... 4 56 3RA6400-1CB43 3RA6400-2CB43
5.5 3 ... 12 168 3RA6400-1DB43 3RA6400-2DB43
15 8 ... 32 448 3RA6400-1EB43 3RA6400-2EB43
1)
The actual starting and rated data of the motor to be protected must be
considered when selecting the units.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/67
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
3RA64, 3RA65 compact starters for IO-Link > 3RA65 reversing starters IE3 ready IE4 ready IE3/IE4 ready

■ Selection and ordering data


Reversing operation
Rated control supply voltage 24 V DC

Width 90 mm

Rated short-circuit current ICS = 53 kA at 400 V

Two sets of 3RA6940-0A adapters are required for screw


NSB0_01947 fixing.

PU (UNIT, SET, M) = 1
PS* = 1 unit
3RA65 with 3RA6911-1A PG = 42F
auxiliary switch
Standard three-phase Setting range for Instantaneous electronic Article No. Price Article No. Price
motor 4-pole at 400 V AC1) electronic overload release per PU per PU
Standard output P release
Screw terminals Spring-loaded
terminals
kW A A
For DIN-rail mounting or screw fixing,
with 1 pair of main circuit terminals and 1 pair of control circuit terminals
0.09 0.1 ... 0.4 56 3RA6500-1AB42 3RA6500-2AB42
0.37 0.32 ... 1.25 56 3RA6500-1BB42 3RA6500-2BB42
1.5 1 ... 4 56 3RA6500-1CB42 3RA6500-2CB42
5.5 3 ... 12 168 3RA6500-1DB42 3RA6500-2DB42
15 8 ... 32 448 3RA6500-1EB42 3RA6500-2EB42
For use in the infeed system for 3RA6,
without main circuit terminals, with 1 pair of control circuit terminals
0.09 0.1 ... 0.4 56 3RA6500-1AB43 3RA6500-2AB43
8

0.37 0.32 ... 1.25 56 3RA6500-1BB43 3RA6500-2BB43


1.5 1 ... 4 56 3RA6500-1CB43 3RA6500-2CB43
5.5 3 ... 12 168 3RA6500-1DB43 3RA6500-2DB43
15 8 ... 32 448 3RA6500-1EB43 3RA6500-2EB43
1) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.

* You can order this quantity or a multiple thereof.


8/68 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Accessories

■ Overview
Accessories for SIRIUS 3RA6 compact starters Busbar adapters for 60 mm systems
The following accessories are available specially for the 3RA6 The compact starters are mounted directly with the aid of busbar
compact starters: adapters on busbar systems with 60 mm center-to-center
• Infeed system for 3RA6, see page 8/76 onwards clearance in order to save space and to reduce infeed times
and costs. These feeders are suitable for copper busbars with
• For AS-i add-on modules, see "Add-on modules for a width from 12 to 30 mm. The busbars can be 4 to 5 mm
AS-Interface", page 8/74 onwards or 10 mm thick.
• External auxiliary switches: Snap-on auxiliary switch as
versions 2 NO, 2 NC and 1 NO + 1 NC with screw or spring- The 8US busbar system can be loaded with a maximum
loaded terminals; the contacts of the auxiliary switch open and summation current of 630 A.
close jointly with the main contacts of the compact starter. The "reversing starter" version requires a device holder
The NC contacts are designed as mirror contacts. alongside the busbar adapter for lateral mounting.
• Control kit: Aid for manually closing the main contacts in order The compact starters are snapped onto the adapter and
to check the wiring and motor direction under conditions of connected on the line side. This prepared unit is then plugged
short-circuit protection directly onto the busbar system, and is thus connected both
• Adapter for screw fixing the compact starter, including mechanically and electrically at the same time.
push-in lugs
For further accessories, such as incoming and outgoing
• Main circuit terminal: Available with screw and spring-loaded terminals, flat copper profiles etc., see Catalog LV 10.
terminals
• Main circuit terminal mixed connection method: Accessories for SIRIUS 3RA6 compact starters in
With the main circuit terminal mixed connection method, IO-Link version
it is also possible to switch from screw connection on the The following accessories are available specially for the 3RA64,
line side to spring-loaded terminals on the outgoing side in 3RA65 compact starters:
the main circuit. • Additional connecting cables for side-by-side mounting of up
This means for example that several compact starters can be to four compact starters
mounted side by side and be cost-efficiently connected using
the 3-phase busbars on the infeed side. The motors are then • Operator panel for on-site control and diagnostics of up to four
connected directly by the quick and reliably contacting compact starters coupled to each other
spring-loaded terminals.

8
Accessories for UL applications
The terminal block for "Self-Protected Combination Motor
Controller (Type E)" is available for complying with the clearance
and creepage distances required according
to UL 508.
Accessories for infeed using 3-phase busbar systems
The 3RV1915-1.B 3-phase busbars can be used as an easy,
time-saving and clearly arranged means of feeding
SIRIUS 3RA6 compact starters with screw terminals.
Motor starter protector sizes S00 and S0 can also be integrated.
The busbars are suitable for between two and five devices.
However, any kind of extension up to a maximum summation
current of 63 A is possible by clamping the tags of an additional
busbar (rotated by 180°) underneath the terminals of the
respective last circuit breaker.
Motor starter protectors S00 and S0 of the 3RV2 series can be
combined in any way. The motor starter protectors are supplied
by appropriate infeed terminals. Special infeed terminals are
required for constructing "Starters (Type E)" according to
UL/CSA.
The 3-phase busbar systems have touch protection but empty
connection tags must be fitted with covers. They are designed
for any short-circuit stress which can occur at the output side of
connected SIRIUS 3RA6 compact starters or motor starter
protectors.

Siemens IC 10 · 2023 8/69


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Accessories

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Accessories specially for 3RA6 compact starters


Control kit 3RA6950-0A 1 1 unit 42F
For mechanical actuation of the
compact starter

3RA6950-0A
Adapters for screw fixing the 3RA6940-0A 1 1 unit 42F
compact starter
(set including push-in lugs)
Direct-on-line starters require one set,
reversing starters two sets.

3RA6940-0A
Screw terminals

Auxiliary switches for compact starters


• 2 NO 3RA6911-1A 1 1 unit 42F
• 2 NC 3RA6912-1A 1 1 unit 42F
• 1 NO + 1 NC (these auxiliary contacts are force-guided) 3RA6913-1A 1 1 unit 42F
3RA6911-1A
Main circuit terminals 3RA6920-1A 1 1 unit 42F
(line side and outgoing side)
8

3RA6920-1A
Control circuit terminals
(1 set comprising 2 terminals)
• For 3RA61 3RA6920-1B 1 1 unit 42F
• For 3RA62 3RA6920-1C 1 1 unit 42F
3RA6920-1B
Spring-loaded
terminals
Auxiliary switches for compact starters
• 2 NO 3RA6911-2A 1 1 unit 42F
• 2 NC 3RA6912-2A 1 1 unit 42F
• 1 NO + 1 NC (these auxiliary contacts are force-guided) 3RA6913-2A 1 1 unit 42F
3RA6911-2A
Main circuit terminals 3RA6920-2A 1 1 unit 42F
(line side and outgoing side)

3RA6920-2A
Control circuit terminals
(1 set comprising 2 terminals)
• For 3RA61 3RA6920-2B 1 1 unit 42F
• For 3RA62 3RA6920-2C 1 1 unit 42F
3RA6920-2B

* You can order this quantity or a multiple thereof.


8/70 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Accessories

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Accessories specially for 3RA6 compact starters (continued)


Main circuit terminals, mixed connection method 3RA6920-3A 1 1 unit 42F
1 set comprises:
• 1 joint block on the line side with screw terminals
• 1 joint block on the outgoing side with spring-loaded
terminals

3RA6920-3A

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Accessories specially for 3RA64, 3RA65 compact starters for IO-Link


Additional connecting cables (flat) for side-by-side
mounting of up to 4 compact starters
• 10-pole
- 8 mm1) 3RA6932-0A 1 5 units 42F
- 200 mm1) 3RA6933-0B 1 5 units 42F
• 14-pole
- 8 mm2) 3RA6931-0A 1 5 units 42F
- 200 mm 3RA6933-0C 1 5 units 42F
3RA6931-0A
Operator panels (set) 3RA6935-0A 1 1 unit 42F
• 1 operator panel
• 1 enabling module
• 1 interface cover

8
• 1 fixing terminal
3RA6935-0A
Enabling modules (replacement) 3RA6936-0A 1 1 unit 42F
Interface covers (replacement) 3RA6936-0B 1 5 units 42F
Connecting cables (round) 3RA6933-0A 1 1 unit 42F
For connecting the operator panel
10-pole, 2 000 mm
1)
10-pole connecting cables are required for EMERGENCY OFF group
concepts.
2)
Is included in the scope of supply of the SIRIUS 3RA6 compact starter
in IO-Link version.
Matching IO-Link masters, see page 2/98 onwards.

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Terminals for "Self-Protected Combination Motor Controllers (Type E)"


according to UL 508 for infeed through parallel wiring with compact starters
Terminal blocks Type E 3RV2928-1H 1 1 unit 41E
For extended clearance and creepage distances
(1 and 2 inch)
Note:
3RV2928-1H UL 508 demands 1-inch clearance and 2-inch
creepage distance at line side for "Combination motor
controller (Type E)". Terminal blocks are not required
for use according to CSA. These terminal blocks
cannot be used in combination with 3RV19.5 3-phase
busbars.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/71
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Accessories

Number of compact Modular Rated For Article No. Price PU PS* PG


starters and motor spacing current In motor per PU (UNIT,
starter protectors at 690 V starter SET, M)
Without lateral protectors
accessories
mm A Size
3-phase busbars for infeed with 3RA6
For feeding several compact starters and/or motor starter
protectors with screw terminals, mounted side-by-side on
DIN rails, insulated, with touch protection.
3RV1915-1AB
2 45 63 S00, S01) 3RV1915-1AB 1 1 unit 41E
3 45 63 S00, S01) 3RV1915-1BB 1 1 unit 41E
4 45 63 S00, S01) 3RV1915-1CB 1 1 unit 41E
3RV1915-1BB 5 45 63 S00, S01) 3RV1915-1DB 1 1 unit 41E

3RV1915-1CB

3RV1915-1DB
1)
Not suitable for 3RV21 motor starter protectors for motor protection
with overload relay function and for 3RV27 and 3RV28 circuit breakers
according to UL 489/CSA C22.2 No. 5.

Version Modular For motor Article No. Price PU PS* PG


spacing starter per PU (UNIT,
protectors SET, M)
mm Size
Covers for connection tags of the 3-phase busbars
Touch protection for -- S00, S0 3RV1915-6AB 1 10 units 41E
empty positions
8

3RV1915-6AB

Conductor cross-section Tightening For Article No. Price PU PS* PG


Solid or Finely AWG torque compact per PU (UNIT,
stranded stranded cables, solid starters SET, M)
with end or stranded and motor
sleeve starter
protectors
mm² mm² AWG Nm Size
3-phase infeed terminals for 3-phase busbars according to IEC
and for constructing "Starters (Type E)" according to UL 508
Connection from top
2.5 … 25 2.5 … 16 10 ... 4 3 ... 4 S00, S0 3RV2925-5EB 1 1 unit 41E

3RV2925-5EB
3-phase infeed terminals for 3-phase busbars
Connection from below1)
2.5 … 25 2.5 … 16 10 ... 4 Input: 4; S00, S0 3RV2915-5B 1 1 unit 41E
Output:
2 ... 2.5

3RV2915-5B
1)
This terminal is connected in place of a compact starter, please take the
space requirement (45 mm) into account.

* You can order this quantity or a multiple thereof.


8/72 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Accessories

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Busbar adapters for 60 mm systems


For copper busbars according to DIN 46433 8US1211-1NS10 1 1 unit 14O
Width: 12 ... 30 mm
Thickness: 4 ... 5 mm or 10 mm

8US1211-1NS10
Device holders for lateral mounting alongside the busbar adapter
for 60 mm systems
Required in addition to the busbar adapter for mounting 8US1250-1AA10 1 1 unit 14O
a reversing starter

8US1250-1AA10
Tools for opening spring-loaded terminals
Screwdriver Spring-loaded
For all SIRIUS devices with spring-loaded terminals terminals
Length, approx. 200 mm, 3RA2908-1A 1 1 unit 41B
3.0 mm x 0.5 mm,

8
titanium gray/black,
3RA2908-1A partially insulated
Blank labels
Unit labeling plates1) 3RT2900-1SB20 100 340 units 41B
For SIRIUS devices
20 mm x 7 mm,
titanium gray
IC01_00181

3RT2900-1SB20
Manuals
System Manual for 3RA6 compact starter and infeed system for
the 3RA6, see
https://support.industry.siemens.com/cs/ww/en/view/27865747
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see page 16/18).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/73
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Add-on modules for AS-Interface

■ Overview
Various AS-i add-on modules are available for communication
of the 3RA6 compact starter with the control system using AS-i D0
AS-Interface: 3RA6120-..B3.

• Standard version
• With two local inputs
• With two free external inputs D1
AS-i
• With one free external input and one free external output
• With two free external outputs
• For local control
Y4
The AS-i add-on modules can be combined only in connection S0
with compact starters with a rated control supply voltage of AUX PWR + +
Y2
24 V AC/DC.
S1
AUX PWR - +
AS-i add-on module for local control S2

With this new module it is also possible for the connected 3RA6970-3F Automatic- 0 - Manual
compact starter to be operated directly using simple switches, Switch with 3 switch positions
i.e. without recourse to AS-i communication, if required. Shown in "0" position

"Automatic" mode Switch with 3 switch positions


NC contacts can be connected to the inputs Y2 and Y4 through Switch Automatic 0 Manual
the local terminals on the AS-i add-on module. If the "+"
S0 Closed Open Open

NSB0_02096a
connections are connected simultaneously to both local inputs,
the AS-i add-on module will be in "Automatic" mode, i.e. it will S1 Closed Open Open
communicate with the control system through AS-Interface. S2 Open Open Closed
Local control
Opening the two inputs Y2 and Y4 will result in the direct Circuit diagram example for controlling a 3RA6120 direct-on-line starter
disconnection of the compact starter. Operation through using an AS-i add-on module for local control
AS-i communication is finished and the compact starter can
8

now be switched on and off directly using NO contacts (one


NO contact per direction of rotation on the reversing starter). AS-i D0
3RA6250-..B3.
"LED AUX Power" must light up green, the 24 V DC supply must
be ensured and the AS-i control supply voltage must no longer
be applied. D1

Resetting to "Automatic" mode AS-i


If a "1" signal is simultaneously applied at the local inputs, Switch with 2
the availability bit DI 0 is switched to a "1" signal. switch positions

LEFT - RIGHT
If AS-i communication is reset, the motor is first switched off and Y4 S4
then on again when requested by the control system. AUX PWR + + S0

Y2
S1 S3
AUX PWR - +
S2

3RA6970-3F Automatic- 0 - Manual


Switch with 3 switch positions
Shown in "0" and "Right" position

Switch with 3 switch positions

Switch Automatic 0 Manual


S0 Closed Open Open
S1 Closed Open Open
S2 Open Open Closed

Switch with 2 switch positions

Switch LEFT RIGHT


NSB0_02097a

S3 Open Closed
S4 Closed Open

Circuit diagram example for controlling a 3RA6250 reversing starter


using an AS-i add-on module for local control

8/74 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Add-on modules for AS-Interface

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

AS-i add-on modules


Standard version 3RA6970-3A 1 1 unit 42F
For communication of the compact starter with the
control system through AS-Interface
With two local inputs 3RA6970-3B 1 1 unit 42F
For safe disconnection through local safety relays,
3RA6970-3A e.g. cable-operated switches
With two free external inputs 3RA6970-3C 1 1 unit 42F
Replaces the digital standard inputs
"Motor On" and "Group warning"
With one free external input and one free external 3RA6970-3D 1 1 unit 42F
output
Replaces the digital standard input
3RA6970-3B to -3F "Group warning"
With two free external outputs 3RA6970-3E 1 1 unit 42F
Only for direct-on-line starters,
replaces the digital standard input
"Motor CCW"
For local control 3RA6970-3F 1 1 unit 42F
Control of the compact starter optionally using
AS-Interface or local switches
Spare parts for AS-i add-on modules
Connection plugs for data and auxiliary supply cable
With 2 insulation displacement terminations for standard
stranded wires 2 x 0.5 ... 0.75 mm2
• Flat, yellow, extender 3RK1901-0NA00 1 5 units 42C

8
• Flat, black, extender 3RK1901-0PA00 1 5 units 42C
3RK1901-0NA00,
3RK1901-0PA00
Accessories for AS-i add-on modules
AS-Interface addressing unit V3.0 3RK1904-2AB02 1 1 unit 42C
• For AS-Interface modules and sensors and
actuators with integrated AS-Interface according
to AS-i specification V3.0
• For setting the AS-i address of standard slaves, and
slaves with extended addressing mode (A/B slaves)
• With input/output test function and many other
commissioning functions
• Battery operation with four type AA batteries
(IEC LR6, NEDA 15)
• Scope of supply:
- Addressing unit with four batteries
- Addressing cable, with M12 plug to addressing plug
(hollow plug), length 1.5 m
3RK1904-2AB02

For matching AS-Interface masters, routers and power supply


units, see pages 2/29, 2/41 and 2/67 onwards.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/75
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Infeed system for 3RA6

■ Overview
More information
Homepage, see www.siemens.com/sirius-infeed-system Online configurator, see www.siemens.com/sirius/configurators
Industry Mall, see www.siemens.com/product?3RA68

The infeed system for 3RA6 compact starters enables far less the main circuit without a compact starter needing to be
wiring in the main circuit and, thanks to the easy exchangeability connected at the same time. As the result of the removable
of the compact starters, reduces the usual downtimes for terminals in the main circuit, compact starters can be integrated
maintenance work during the plant's operating phase. The in an infeed system in easy manner (without the use of tools).
infeed system provides the possibility of completely prewiring

3
4

1
9

IC01_00648
5
8

11
12
10

1 Infeed terminal 7 PE pick-off


2 3-socket expansion module 8 Connecting wedges
3 2-socket expansion module 9 End cover
4 Expansion plug 10 45 mm adapter for SIRIUS motor starter protector size S0
5 PE infeed 11 3RA61 direct-on-line starter
6 PE expansion plug 12 3RA62 reversing starter

Infeed system for 3RA6 compact starters

8/76 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Infeed system for 3RA6
In addition, the integrated PE bar means it is optionally possible + PE pick-off
to connect the motor cable directly to the infeed system without
additional intermediate terminals. The infeed system for The PE pick-off is available with screw terminals and spring-
3RA6 compact starters is designed for summation currents loaded terminals (6/10 mm2). It is snapped into the infeed
up to 100 A with a maximum conductor cross-section of system from below.
up to 70 mm² on the infeed terminal block.
, Connecting wedges
The infeed system can be mounted on a DIN rail or flat surfaces.
Two connecting wedges are used to hold together two
$ Infeed expansion modules.
The 3-phase infeed is available as an infeed with screw terminal - End covers
(25/35 mm2 up to 63 A or 50/70 mm2 up to 100 A) and as an
infeed with spring-loaded terminal (25/35 mm2 up to 63 A). On the last expansion module of a row, the socket provided for
the expansion plug can be covered by inserting the end cover.
The infeed with spring-loaded terminal can be fitted on the left
as well as on the right of an expansion module. . 45 mm adapter for SIRIUS motor starter protectors
size S0
The infeed with screw terminal is supplied only with a 3-socket
expansion module and permanently fitted on the left side. SIRIUS 3RV2 motor starter protectors size S0 with screw
terminals can be fitted to the adapter, enabling them to be
The infeeds with screw terminal enable connection of the main plugged into the infeed system.
conductors (L1, L2, L3) either from above or from below.
Terminal covers for increasing finger protection on
The infeed with screw terminal is supplied complete with one the front
end cover, the infeed with spring-loaded terminal complete with
two end covers. Universally configured terminal covers are available for the
25/35 mm2 and 50/70 mm2 3-phase infeeds with screw terminal:
% 3-socket expansion module • 3RA6880-2AB terminal covers for infeeds with screw terminal
The expansion module with three sockets for compact starters is 25/35 mm2 (3RA6812-8AB/AC)
available with screw terminals and with spring-loaded terminals. • 3RA6880-3AB terminal covers for infeeds with screw terminal
Expansion modules enable the infeed system to be expanded 50/70 mm2 (3RA6813-8AB/AC)
and can be fitted to each other in any number. The terminal covers can be used in two ways on the infeed
Two expansion modules are held together with the help of two terminals of the infeeds with screw terminal 25/35 mm² and
connecting wedges and one expansion plug. These assembly 50/70 mm² (see illustration):

8
parts are included in the scope of supply of the respective • If the terminals are connected, the cables are also covered:
expansion module. - by approx. 14 mm with the 3RA6880-2AB
- by approx. 18 mm with the 3RA6880-3AB
When the infeed system for 3RA6 compact starters is used,
the compact starters (plug-in modules) are easily assembled • On clamping points without connected cables, the covers can
and disassembled even when live. be turned once and then pushed over the clamping points for
finger-safe covering of the metal parts.
Optional possibilities:
• PE connection on motor outgoing side
• Outfeed for external auxiliary devices
• Connection to 3RV29 infeed system
• Integration of SIRIUS 3RV2 motor starter protectors size S0
up to 25 A (using 3RA6890-0BA adapter)

& 2-socket expansion module


If only two instead of three additional sockets are required,
then the 2-socket expansion module is the right choice. It has
the same functionality as the 3-socket expansion module.
( Expansion plug
Two expansion modules can be connected together using
the expansion plug. Flexible expansion of the infeed system
is thus possible.

) PE infeed
This module enables a PE cable to be connected.
Use of the 3RA6880-2AB terminal cover on the infeed with screw terminal
The PE infeed can be ordered with screw terminals and spring- 25/35 mm² (3RA6812-8AB/AC). The upper cover increases the finger-
loaded terminals (35 mm2) and can be fitted on the left or right safety for the connected conductors. The identical lower cover is turned
of the expansion block. for use and prevents touching of the voltage-carrying metal parts of
the infeed terminal. For better recognition, the covers are shown as
* PE expansion plug transparent in this illustration and not in their original color.
The PE expansion plug is inserted from below and enables two
PE bars to be connected.

Siemens IC 10 · 2023 8/77


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Infeed system for 3RA6
Terminal blocks Proposal for upstream short-circuit protection devices
Using the terminal block the three phases can be fed out of The following short-circuit data apply for the components of
the system; this means that 1-phase, 2-phase and 3-phase the infeed system for 3RA6 compact starters:
components can also be integrated in the system.
Conduc- Maximum let-through Proposal for Maxi-
After the end cover is pulled out, the terminal block can be tor current Id,max and upstream mum
plugged onto an expansion module. cross- current integral I2t short-circuit prospec-
section protection device tive
Expansion plug for SIRIUS 3RV29 infeed systems Ishort-
circuit
After the end cover is pulled out, the expansion plug for the mm² kA
SIRIUS 3RV29 infeed system can be plugged onto an expansion
Short-circuit protection for
module. It connects the infeed system for 3RA6 compact 3RA681.-8A. infeed with screw terminal
starters with the SIRIUS 3RV29 infeed system. (25/35 mm2 and 50/70 mm2)
Maximum rated operational current 2.5 … 35 Id, max < 21 kA, I²t = 530 kA²s 3RV2041-4MA10 50
2.5 ... 70 (NH gG 3NA3; 315 A)
The following maximum rated operational currents apply for
the components of the infeed system for 3RA6: Short-circuit protection for infeed
with spring-loaded terminal 25/35 mm2,
3RA6830-5AC
Component Maximum rated
operational current 4 Id, max < 9.5 kA, I²t = 85 kA²s 3RV2021-4DA10 40
A 6 Id, max < 12.5 kA, I²t = 140 kA²s 3RV2031-4EA10 30
Infeed with screw terminal 50/70 mm² 100 10 Id, max < 15 kA, I²t = 180 kA²s 3RV2031-4WA10 25
Infeed with screw terminal 25/35 mm² 63 16/25 Id, max < 19 kA, I²t = 440 kA²s 3RV2031-4JA10 65
Infeed with spring-loaded terminal 25/35 mm² 63 3RV2041-4JA10 65
Expansion plug 63 35 Id, max < 21 kA, I²t = 530 kA²s 3RV2041-4MA10 50
(NH gG 3NA3; 315 A)
With side-by-side mounting of several expansion modules, Short-circuit protection for terminal
the maximum rated operational current from the second block, 3RV2917-5D
expansion module to the end of the row is 63 A. 1.5 Id, max < 7.5 kA 5SY...
1)
2.5 Id, max < 9.5 kA
4 Id, max < 9.5 kA
6 Id,max < 12.5 kA
8

1)
To prevent the possibility of short circuits, the cables on the terminal block
must be installed so that they are short-circuit-proof.

8/78 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Infeed system for 3RA6

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

3-phase infeeds and expansion modules


Infeeds with screw terminal 25/35 mm2 left
Infeed with screw terminal at line side with
a permanently fitted 3-socket expansion module
with screw or spring-loaded terminals on the
outgoing side and integrated PE bar
Expansion module with 3 sockets for
3 direct-on-line starters or 1 direct-on-line starter
and 1 reversing starter
Screw terminals
3RA6812-8AB
• Screw terminals on the outgoing side 3RA6812-8AB 1 1 unit 42F

Spring-loaded
terminals
• Spring-loaded terminals on the outgoing side 3RA6812-8AC 1 1 unit 42F

3RA6812-8AC
Infeeds with screw terminal 50/70 mm2 left
Infeed with screw terminal at line side with
a permanently fitted 3-socket expansion module
with screw or spring-loaded terminals on the
outgoing side and integrated PE bar
Expansion module with 3 sockets for

8
3 direct-on-line starters or 1 direct-on-line starter
and 1 reversing starter,
suitable for UL operation according to UL 508
3RA6813-8AB Type E
Screw terminals

• Screw terminals on the outgoing side 3RA6813-8AB 1 1 unit 42F


Spring-loaded
terminals
• Spring-loaded terminals on the outgoing side 3RA6813-8AC 1 1 unit 42F

3RA6813-8AC
Infeeds with spring-loaded terminals
25/35 mm2 left or right
Spring-loaded
terminals
Up to 63 A 3RA6830-5AC 1 1 unit 42F

3RA6830-5AC

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/79
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Infeed system for 3RA6

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Expansion modules
2-socket expansion modules
With screw or spring-loaded terminals
and integrated PE bar
With 2 sockets for 2 direct-on-line starters or
1 reversing starter
Expansion plug and 2 connecting wedges
are included in the scope of supply.
Screw terminals

• Version with screw terminals 3RA6822-0AB 1 1 unit 42F


3RA6822-0AB
Spring-loaded terminals

• Version with spring-loaded terminals 3RA6822-0AC 1 1 unit 42F

3RA6822-0AC
3-socket expansion modules
With screw or spring-loaded terminals
and integrated PE bar
With 3 sockets for 3 direct-on-line starters or
1 direct-on-line starter and 1 reversing starter
Expansion plug and 2 connecting wedges
are included in the scope of supply.
Screw terminals
8

• Version with screw terminals 3RA6823-0AB 1 1 unit 42F


3RA6823-0AB
Spring-loaded terminals

• Version with spring-loaded terminals 3RA6823-0AC 1 1 unit 42F

3RA6823-0AC

* You can order this quantity or a multiple thereof.


8/80 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Infeed system for 3RA6

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Accessories for infeed systems for 3RA6


PE infeeds, 25/35 mm2
Screw terminals

• Version with screw terminals 3RA6860-6AB 1 1 unit 42F

3RA6860-6AB
Spring-loaded
terminals
• Version with spring-loaded terminals 3RA6860-5AC 1 1 unit 42F

3RA6860-5AC
PE pick-offs 6/10 mm2
Screw terminals

• Version with screw terminals 3RA6870-4AB 1 1 unit 42F

8
3RA6870-4AB
Spring-loaded
terminals
• Version with spring-loaded terminals 3RA6870-3AC 1 1 unit 42F

3RA6870-3AC
Expansion plugs
PE expansion plugs 3RA6890-0EA 1 1 unit 42F

3RA6890-0EA
Expansion plugs 3RA6890-1AB 1 1 unit 42F
Between 2 expansion modules
Included in the scope of supply of the expansion
modules

3RA6890-1AB
Expansion plugs for SIRIUS 3RV29 infeed system 3RA6890-1AA 1 1 unit 42F
Connect infeed system for 3RA6 to
3RV29 infeed system

3RA6890-1AA

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/81
© Siemens 2023

Load feeders and motor starters for use in the control cabinet
SIRIUS 3RA6 compact starters
Infeed system for 3RA6

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Accessories for infeed systems for 3RA6 (continued)


45 mm adapters
For SIRIUS 3RV2.2 motor starter protectors/circuit breakers Screw terminals
size S0 up to 25 A
• Screw terminals 3RA6890-0BA 1 1 unit 42F
(conductor cross-section AWG 10)

3RA6890-0BA
Terminal covers for infeeds with screw terminals
IP20 terminal covers for infeeds with screw terminal 3RA6880-2AB 1 1 unit 42F
25/35 mm² (3RA6812-8AB/AC)
(2 units per pack)

3RA6880-2AB
IP20 terminal covers for infeeds with screw terminal 3RA6880-3AB 1 1 unit 42F
50/70 mm² (3RA6813-8AB/AC)
(2 units per pack)

3RA6880-3AB
8

Terminal blocks
For integration of 1-phase, 2-phase and 3-phase external Spring-loaded
components terminals
• Spring-loaded terminals 3RV2917-5D 1 1 unit 41E

3RV2917-5D
Tools for opening spring-loaded terminals
Screwdriver
For all SIRIUS devices with spring-loaded terminals Spring-loaded
terminals
Length, approx. 200 mm, 3RA2908-1A 1 1 unit 41B
3.0 mm x 0.5 mm,
titanium gray/black,
3RA2908-1A partially insulated
Manuals
System Manual for 3RA6 compact starter and
infeed system for 3RA6, see
https://support.industry.siemens.com/cs/ww/en/view/27865747

* You can order this quantity or a multiple thereof.


8/82 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet

SIRIUS 3RM1 motor starters

■ Overview
1 3RM1 motor starters

2 Fuse modules
3 Adapters for busbar
systems/DIN rails
4
4 Device connectors
5 3-phase infeed system
6 Covers for infeed busbars
7 Sealable covers
8 Push-in lugs for wall mounting

8 3
2
1

7
6

IC01_00751

8
5

SIRIUS 3RM1 motor starters with accessories

SIRIUS 3RM1 motor starters are compact devices, 22.5 mm


More information wide, combining a large number of functions in a single
3RM1 motor starters: enclosure. They consist of combinations of relay contacts,
• Homepage, see www.siemens.com/sirius-motor-starter-3RM1 power semiconductors (hybrid technology), and an electronic
• Industry Mall, see www.siemens.com/product?3RM1 overload relay for operational switching of three-phase motors
• Online configurator, see www.siemens.com/sirius/configurators up to 3 kW (at 400 V) and resistive loads up to 10 A at
3SK safety relays for protecting the 3RM1 motor starters: AC voltages up to 500 V.
• Homepage, see www.siemens.com/sirius-safety-relays
• Industry Mall, see www.siemens.com/product?3SK The 3RM1 motor starters with overload protection with wide
TIA Selection Tool Cloud (TST Cloud), see setting range are available as direct-on-line starters and
www.siemens.com/tstcloud/?node=MotorStarter3RM1 reversing starters and as versions with safety-related shutdown
Decision support for motor start – Starting and operating three-phase up to SIL 3 and PL e.
asynchronous motors efficiently, see www.siemens.com/motorstart-guide
Industry Online Support (SIOS) topic page with information on
the planning and operating phases, see
https://support.industry.siemens.com/cs/ww/en/view/109792664

Video: SIRIUS 3RM1 motor starters – Compact, economical, simple

Siemens IC 10 · 2023 8/83


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

SIRIUS 3RM1 motor starters


Seamlessly integrated safety right through to the main circuit Online configurator

Online configurator
An online configurator with a wide range of functions is available
for the SIRIUS 3RM1 motor starters.
(see www.siemens.com/sirius/configurators):
• Create individual motor starters or a complex motor
starter group
• Individual selection options, such as direct or reversing
starting, spring-loaded or screw terminals, as well as motor
3SK + 3RM1 current and control voltage
IC01_00533

• Graphic representation of the design during configuration


• Automatic calculation of the matching motor starter
protector/circuit breaker (for group configuration)
Ordering notes for multi-unit packaging
SIRIUS 3RM1 motor starters can also be ordered in practical,
Problem-free integration of functional safety into the main circuit through environment-friendly multi-unit packaging on request.
8

the simple combination of 3RM1 and 3SK devices Multi-unit packaging with order code X90
Functional safety in the main circuit needs to be both simple and When ordering products in multi-unit packaging, the article
flexible. number of the product concerned must be supplemented with
The unique compatibility of hybrid 3RM1 fail-safe motor starters "-Z" and, in addition, the order code "X90" must be specified.
and 3SK safety relays means that integrated functional safety Ordering example:
right through to the main circuit is no longer a problem.
3RM1201-2AA04-Z X90;
Their compact design allows the motor starters to be installed to purchase order quantity 12 units  Delivery of one package
the right of the safety relay in a simple manner, just like an output containing 12 units
expansion. The wiring of the safety-related signals to the relay
can be performed simply, quickly and in an error-free manner For more information, see page 16/7.
using the device connector.
The ergonomically designed enclosure with removable
terminals and terminal labeling in the hinged cover allows for the
cables to be conveniently diagonally mounted from the front.
Either screw or spring-loaded terminals with push-in technology
are available.
Highlights
• Fail-safe disconnection of motors up to 3 kW
• Problem-free combination of fail-safe motor starters and
safety relays
• End-to-end system, simple setup using device connectors
• Ergonomic enclosure
Note:
For SIRIUS 3SK safety relays, see page 11/13.

8/84 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

SIRIUS 3RM1 motor starters


Article number scheme
Product versions Article number
Product function Direct-on-line starters 3RM10 0 @ – @ AA @ 4
Failsafe direct-on-line starters 3RM11 0 @ – @ AA @ 4 With ATEX certification and safety-related shutdown
Reversing starters 3RM12 0 @ – @ AA @ 4
Failsafe reversing starters 3RM13 0 @ – @ AA @ 4 With ATEX certification and safety-related shutdown
Wide setting range for 0.1 ... 0.5 A 1 For motor standard output 0 ... 0.12 kW2)
electronic overload 0.4 ... 2.0 A 2 For motor standard output 0.09 ... 0.75 kW2)
release
1.6 ... 7.0 A (10 A)1) 7 For motor standard output 0.55 ... 3 kW2)
Connection method Screw terminals 1
Spring-loaded terminals 2
(push-in)
Mixed connection method 3 Spring-loaded terminals (push-in)
Rated control supply 24 V DC 0
voltage Us 110 ... 230 V AC, 110 V DC 1
Example 3RM13 0 1 – 2 AA 0 4
1) 2)
Operation of resistive loads with up to 10 A. Standard three-phase motor, basis 4-pole at 400 V AC; the actual starting
and rated data of the motor to be protected must be considered when
selecting the units.
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

■ Benefits
• Less space required in the control cabinet (20 to 80%) thanks • Virtually error-free wiring on the mains connection side and
to high functional density, which also means reduced wiring reduction in short-circuit protective devices by means of
and testing 3RM19 infeed system

8
• Greater endurance and reduced heat losses thanks to hybrid • ATEX certification of the overload protection of the
technology 3RM1 Failsafe motor starters: "Increased safety" type of
• Lower costs for stock keeping and configuration as a result protection EEx e according to ATEX directive 2014/34/EU
of the wide setting range of the electronic overload release • The 3RM1 motor starters can be used with highly efficient
(up to 1:5) IE3 and IE4 motors. In this regard, please observe the
• Fast wiring without tools for rigid conductors or conductors information on dimensioning and configuring, see
equipped with end sleeves thanks to spring-loaded terminals Application Manual.
(push-in) For more information, see page 1/8.
• Safety-related shutdown in accordance with SIL 3 and PL e by Standards and approvals
shutting down the control supply voltage without additional • IEC/EN 60947-4-2
devices in the main circuit • UL 60947-4-2
• The motor starters can be ideally combined with 3SK safety • CSA1)
relays for safety-related shutdown (see page 11/13) • ATEX
• Motor status feedback to the higher-level control system in • IEC 61508: SIL 3
the case of 3RM10 and 3RM12 motor starters in the 24 V DC • IEC 62061: SIL 3
version • ISO 13849-1: PL e
• CCC approval for China
1)
The CSA approval is valid for a maximum operational voltage of 400 V,
see https://support.industry.siemens.com/cs/ww/en/view/109481789.

Siemens IC 10 · 2023 8/85


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

SIRIUS 3RM1 motor starters

■ Technical specifications
More information
Industry Mall, see www.siemens.com/product?3RM1 FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16311/faq
Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/66295730

Article number 3RM1


General technical specifications
Dimensions (W x H x D) mm 22.5 x 100 x 141.6
Ambient temperature
• During operation °C -25 … +60
• During storage °C -40 … +70
• During transport °C -40 … +70
Installation altitude at height above sea level, maximum m 4 000 (observe derating)
Shock resistance 6 g/11 ms
Vibration resistance 1 ... 6 Hz, 15 mm; 20 m/s², 500 Hz
Degree of protection IP on the front According to IEC 60529 IP20
Touch protection on the front According to IEC 60529 Finger-safe for vertical touching from the front
Mounting position Vertical, horizontal, standing (consider derating)

IC01_00469

Article number 3RM1.01 3RM1.02 3RM1.07


Main circuit
Operational voltage, rated value, maximum V 500
Operating frequency Hz 50/60
Operational current at AC-53a at 400 V at an ambient temperature of 40 °C A 0.5 2 7
8

Minimum load [%] % 20


Adjustable current response value of the inverse-time delayed overload release A 0.1 ... 0.5 0.4 ... 2 1.6 ... 7

Article number 3RM1.0.-.AA04 3RM1.0.-.AA14


Control circuit
Type of voltage of the control supply voltage DC AC/DC
Control supply voltage
• At DC V 24 110
• At AC at 50 Hz V -- 110 … 230
Frequency of the control supply voltage Hz -- 50/60

Type 3RM1.0.-1AA.4 3RM1.0.-3AA.4 3RM1.0.-2AA.4


Connections/terminals
Type of electrical connection for the main circuit Screw terminals Spring-loaded
(1 or 2 conductors can be connected) terminals
(push-in)
Connectable conductor cross-section for main contacts
• Solid mm² 1 x (0.5 ... 4), 2 x (0.5 ... 2.5) 1 x (0.5 ... 4)
• Finely stranded
- With end sleeve mm² 1 x (0.5 ... 4), 2 x (0.5 ... 1.5) 1 x (0.5 ... 2.5)
- Without end sleeve mm² -- 1 x (0.5 ... 4)
Type of electrical connection for auxiliary and control circuits Screw Spring-loaded terminals
(1 or 2 conductors can be connected) terminals (push-in)
Type of connectable conductor cross-sections for auxiliary contacts
• Solid mm² 1 x (0.5 ... 2.5) 1 x (0.5 ... 1.5), 2 x (0.5 ... 1.5)
2 x (1.0 ... 1.5)
• Finely stranded
- With end sleeve mm² 1 x (0.5 ... 2.5) 1 x (0.5 ... 1.0), 2 x (0.5 ... 1.0)
2 x (0.5 ... 1)
- Without end sleeve mm² -- 1 x (0.5 ... 1.5), 2 x (0.5 ... 1.5)
Type of connectable conductor cross-sections for AWG cables
• For main contacts 1 x (20 ... 12), 2 x (20 ... 14) 1 x (20 ... 12)
• For auxiliary contacts 1 x (20 ... 14), 1 x (20 ... 16), 2 x (20 ... 16)
2 x (18 ... 16)

8/86 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

SIRIUS 3RM1 motor starters

■ Accessories
More information
Equipment Manual, see 1
https://support.industry.siemens.com/cs/ww/en/view/66295730

3-phase infeed system (3RM19 3-phase busbar system)


The system permits an easy, time-saving and safe means of
feeding two or more 3RM1 motor starters. It can be used only
with motor starters with screw terminals and in combination with
8US1716-0RK00 adapters for mounting rails in the main circuit.
The maximum summation current must not exceed 25 A.
The primary infeed is connected via a 3-phase infeed terminal.

IC01_00169c
The busbars are available in three lengths, for two, three or five
motor starters. More than five devices can be connected by
clamping the connection tags of a second busbar underneath,
rotated 180°.
The 3-phase busbars have touch protection but empty 4
connection tags must be fitted with covers.

1 Four 3RM1 motor starters on DIN rail with one free slot

8
2 3RM1920-1AA 3-phase infeed terminal
3 Two 3RM1910-1DA 3-phase busbars rotated through 180°
for the connection of up to nine motor starters
4 Covers for three 3RM1910-6AA connection tags respectively
for unused slots

3RM19 infeed system with 3-phase infeed terminal: In the above


example, two 3-phase busbars (5-pole busbars) rotated 180° allow up
to nine 3RM1 motor starters to be connected. Contact with the unused
connection tags in unoccupied positions is prevented safely by
the covers.

Siemens IC 10 · 2023 8/87


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

SIRIUS 3RM1 motor starters


Fuse module for the use of 3RM1 motor starters on 8US busbar systems and mounting rails
The fuse module permits the very compact construction of a load The fuse module can be combined with all 3RM1 motor starters.
feeder with a maximum width of 22.5 mm. The 3RM1 motor starter The easily replaceable fuses protect the motor starter, the
in combination with the integrated fuses for short-circuit protection connected motor and the cables.
can thus be used in this way on 8US busbar systems.
By means of different adapters, the fuse module can be used in
all 60 mm busbar systems and also in compact busbar systems,
as well as on mounting rails. The interface to the adapter also
permits a simple and secure replacement of the load feeder.

5 1 Busbar system
2 3 5
1 4 2 Cover profiles for busbars
3 Busbar adapter
4 Compact busbar adapter

5 3RM1 motor starter


6 3RM19 fuse module
7 3RM19 fuse module with open flap
(Flap cannot be opened when fuse
module is inserted. The fuse
module must be removed to change
the fuses.)

IC01_00611a
8

6
7

By means of the fuse module, 3RM1 motor starters can be used in busbar systems and 8US compact busbar systems as well as on
mounting rails

8/88 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

SIRIUS 3RM1 motor starters


Device connectors for the control circuit Safe group shutdown can be implemented particularly easily in
conjunction with 3SK safety relays. In this case, up to five motor
The device connectors for 3RM1 motor starters (24 V DC control starters can be directly connected to 3SK safety relays via the
supply voltage only) reduce the outlay for cabling by looping device connector and then safely shut down (see page 11/13).
through the control supply voltage. The device connectors can
be snapped onto a DIN rail or fixed to a level mounting panel
using screws. 3SK safety relay 3RM1 motor starter

IC01_00178a
IC01_00218b

Motor

Ideal connection: Combination of four SIRIUS 3RM1 Failsafe motor


starters with SIRIUS 3SK safety relays
Electromechanical switching devices in series with hybrid
motor starters
Switching an inductive load - in particular of motors < 1 kW with
Device connector with 3RM1 motor starter high inductance - with an electromechanical switching device
Using the device connectors exclusively for feeding in the (e.g. contactor) can cause high and steep voltage edges.
control supply voltage The resulting faults/damage can be prevented by first
By using device connectors, a maximum of five motor disconnecting with the hybrid motor starter or by using
starters can be supplied with 24 V DC control supply voltage. EMC suppression modules:
This requires the control supply voltage to be applied to the • For 3RT2916-1P.. EMC suppression modules for direct
mounting on the contactor, see page 3/113

8
A1 and A2 terminals of only one motor starter.
Device daisy chain connectors can be used for gaps between • For motor suppression modules that are fitted in the main
two motor starters. Device termination connectors terminate circuit, see page 8/93
a group. Note:
Using the device connectors for safe group shutdown For more information, see
In combination with the 3RM11 and 3RM13 fail-safe motor https://support.industry.siemens.com/cs/ww/en/view/109758696.
starters, the device connector can also be used for safety-
related shutdown. For this application, groups of no more than
five fail-safe motor starters can be connected using a device
connector, and the group must be terminated with a termination
connector. Removing the control voltage supply from the first
motor starter will safely shut down the whole group.

Siemens IC 10 · 2023 8/89


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

SIRIUS 3RM1 motor starters IE3 ready IE4 ready IE3/IE4 ready

■ Selection and ordering data


More information
Industry Mall, see www.siemens.com/product?3RM1

Multi-unit packaging Ratings Adjustable Control supply Article No. Price PU PS* PG
see page 16/7. of three-phase current response voltage per PU (UNIT,
motors value of the inverse- SET, M)
at 400 V1) time delayed at DC at AC at
overload release 50 Hz
kW A V V
Direct-on-line starters
0 … 0.12 0.1 … 0.5 24 -- 3RM1001-@AA04 1 1 unit 41D
0.09 … 0.75 0.4 … 2 24 -- 3RM1002-@AA04 1 1 unit 41D
0.55 … 3 1.6 … 7 24 -- 3RM1007-@AA04 1 1 unit 41D
0 … 0.12 0.1 … 0.5 110 110 ... 230 3RM1001-@AA14 1 1 unit 41D
0.09 … 0.75 0.4 … 2 110 110 ... 230 3RM1002-@AA14 1 1 unit 41D
0.55 … 3 1.6 … 7 110 110 ... 230 3RM1007-@AA14 1 1 unit 41D

3RM1001-1AA04
Reversing starters
0 … 0.12 0.1 … 0.5 24 -- 3RM1201-@AA04 1 1 unit 41D
0.09 … 0.75 0.4 … 2 24 -- 3RM1202-@AA04 1 1 unit 41D
0.55 … 3 1.6 … 7 24 -- 3RM1207-@AA04 1 1 unit 41D
0 … 0.12 0.1 … 0.5 110 110 ... 230 3RM1201-@AA14 1 1 unit 41D
0.09 … 0.75 0.4 … 2 110 110 ... 230 3RM1202-@AA14 1 1 unit 41D
0.55 … 3 1.6 … 7 110 110 ... 230 3RM1207-@AA14 1 1 unit 41D
8

3RM1201-1AA04
Failsafe direct-on-line starters
0 … 0.12 0.1 … 0.5 24 -- 3RM1101-@AA04 1 1 unit 41D
0.09 … 0.75 0.4 … 2 24 -- 3RM1102-@AA04 1 1 unit 41D
0.55 … 3 1.6 … 7 24 -- 3RM1107-@AA04 1 1 unit 41D
0 … 0.12 0.1 … 0.5 110 110 ... 230 3RM1101-@AA14 1 1 unit 41D
0.09 … 0.75 0.4 … 2 110 110 ... 230 3RM1102-@AA14 1 1 unit 41D
0.55 … 3 1.6 … 7 110 110 ... 230 3RM1107-@AA14 1 1 unit 41D

3RM1101-1AA04
Failsafe reversing starters
0 … 0.12 0.1 … 0.5 24 -- 3RM1301-@AA04 1 1 unit 41D
0.09 … 0.75 0.4 … 2 24 -- 3RM1302-@AA04 1 1 unit 41D
0.55 … 3 1.6 … 7 24 -- 3RM1307-@AA04 1 1 unit 41D
0 … 0.12 0.1 … 0.5 110 110 ... 230 3RM1301-@AA14 1 1 unit 41D
0.09 … 0.75 0.4 … 2 110 110 ... 230 3RM1302-@AA14 1 1 unit 41D
0.55 … 3 1.6 … 7 110 110 ... 230 3RM1307-@AA14 1 1 unit 41D

3RM1301-1AA04
Type of electrical connection
• Screw terminals for main circuit, screw terminals for control circuit 1
• Spring-loaded terminals (push-in) for main circuit, spring-loaded terminals (push-in) 2
for control circuit
• Screw terminals for main circuit, spring-loaded terminals (push-in) for control circuit 3
1) The actual starting and rated data of the motor to be protected must be
considered when selecting the units.

* You can order this quantity or a multiple thereof.


8/90 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet

SIRIUS 3RM1 motor starters

Product designation Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

3-phase infeed system for 3RM1 with screw terminals


3-phase infeed terminals 3RM1920-1AA 1 1 unit 41D
• For 3-phase busbars

3RM1920-1AA
3-phase busbars
• For 2 motor starters 3RM1910-1AA 1 1 unit 41D

3RM1910-1AA
• For 3 motor starters 3RM1910-1BA 1 1 unit 41D

3RM1910-1BA
• For 5 motor starters 3RM1910-1DA 1 1 unit 41D

3RM1910-1DA
Covers 3RM1910-6AA 1 10 units 41D
For 3 connection tags of the

8
3-phase busbars

3RM1910-6AA
Fuse modules for 3RM1 for use on busbars or mounting rails
Fuse module with 3NW6007-1 fuse 3RM1932-1AB 1 1 unit 41D
Fuse module without fuse1) 3RM1930-1AA 1 1 unit 41D

3RM1932-1AB
Adapters
Adapters for 60 mm busbar systems 8US1216-0AS00 1 1 unit 14O
22.5 mm x 200 mm x 41.5 mm
Note: The adapter can be used on busbars with
a width of 12 mm, 15 mm, 20 mm, 25 mm or 30 mm
and a thickness of 5 mm or 10 mm.

8US1216-0AS00
Adapters for 60 mm compact busbar systems 8US1616-0AK02 1 1 unit 14O
22.5 mm x 160 mm x 41.5 mm
Note: The adapter can be used on busbars with
a width of 12 mm and a thickness of 5 mm or 10 mm.

8US1616-0AK02
1) For details of alternative fuses, see Equipment Manual.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/91
© Siemens 2023

Load feeders and motor starters for use in the control cabinet

SIRIUS 3RM1 motor starters

Product designation Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Adapters
Adapter for 35 mm DIN mounting rails 8US1716-0RK00 1 1 unit 14O
22.5 mm x 185 mm x 23.5 mm

8US1716-0RK00
Cover profiles1)2)
Cover profiles for busbars
12 mm x 5 mm x 1 000 mm 8US1922-2CA00 1 10 units 14O
40 mm or 60 mm center-to-center busbar clearance
depending on busbar system
8US1922-2CA00
15 mm x 5 mm x 1 000 mm 8US1922-2AA00 1 10 units 14O
20 mm x 5 mm x 1 000 mm
25 mm x 5 mm x 1 000 mm
30 mm x 5 mm x 1 000 mm
40 mm or 60 mm center-to-center busbar clearance
depending on busbar system
8US1922-2AA00
12 mm x 10 mm x 1 000 mm 8US1922-2BA00 1 10 units 14O
15 mm x 10 mm x 1 000 mm
20 mm x 10 mm x 1 000 mm
25 mm x 10 mm x 1 000 mm
30 mm x 10 mm x 1 000 mm
8

60 mm center-to-center busbar clearance


8US1922-2BA00
Device connectors
Device connectors 3ZY1212-2EA00 1 1 unit 41L
For 3RM1 motor starters, 24 V DC, 22.5 mm

3ZY1212-2EA00
Device daisy chain connectors 3ZY1212-2AB00 1 1 unit 41L
For 3RM1 motor starters, 24 V DC, 22.5 mm
For gaps without motor starters in assemblies

3ZY1212-2AB00
Device termination connectors 3ZY1212-2FA00 1 1 unit 41L
For 3RM1 motor starters, 24 V DC, 22.5 mm

3ZY1212-2FA00
1) The cover profiles for busbars can be used for maintaining minimum
spacing between the load feeders.
2)
For further accessories for the configuration of a busbar system,
see Catalog LV 10.

* You can order this quantity or a multiple thereof.


8/92 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet

SIRIUS 3RM1 motor starters

Product designation Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Removable terminals
Terminals for main circuit, 2-pole
Screw terminals

• Version with screw terminals, 3ZY1122-1BA00 1 6 units 41L


up to max. 1 x 4 mm² or 2 x 2.5 mm²
Spring-loaded terminals
(push-in)
• Version with spring-loaded terminals (push-in), 3ZY1122-2BA00 1 6 units 41L
up to max. 1 x 4 mm² or 2 x 1.5 mm²
3ZY1122-1BA00 (both in one end sleeve)
Terminals for control circuit, 3-pole
Screw terminals

• Version with screw terminals, 3ZY1131-1BA00 1 6 units 41L


up to max. 2 x 1.5 mm² or 1 x 2.5 mm²
Spring-loaded terminals
(push-in)
• Version with spring-loaded terminals (push-in), 3ZY1131-2BA00 1 6 units 41L
up to max. 2 x 1.5 mm²
3ZY1131-1BA00
Further accessories
Push-in lugs for wall mounting 3ZY1311-0AA00 1 10 units 41L
2 lugs per device are required

3ZY1311-0AA00
Sealable covers, 22.5 mm 3ZY1321-2AA00 1 5 units 41L

8
For simple protection against unauthorized access

3ZY1321-2AA00
Coding pins for removable terminals 3ZY1440-1AA00 1 12 units 41L
For mechanical coding of the terminals

3ZY1440-1AA00
Hinged cover
Replacement cover, without terminal labeling,
22.5 mm wide
• Titanium gray 3ZY1450-1AB00 1 5 units 41L
• Yellow 3ZY1450-1BB00 1 5 units 41L

3ZY1450-1AB00
Motor suppression module
• Square 3RK1911-6EA00 1 1 unit 42D
• Round 3RK1911-6EB00 1 1 unit 42D

3RK1911-6EA00
Screwdriver Spring-loaded
For all SIRIUS devices with spring-loaded terminals terminals
Length, approx. 200 mm, 3RA2908-1A 1 1 unit 41B
3.0 mm x 0.5 mm,
titanium gray/black,
3RA2908-1A partially insulated

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/93
© Siemens 2023

Load feeders and motor starters for use in the control cabinet

ET 200SP motor starters

■ Overview

1 2 3 4 5 6 6 7
2

1
IC01_00662a

5 9
1 ET 200SP interface module

IC01_00613a
2 ET 200SP digital input
3 1 ET 200SP fail-safe motor starter 3 ET 200SP digital output
2 BaseUnit for ET 200SP motor starter 4 ET 200SP analog input
7 Dummy module consisting of
3 Fan 5 Dummy module consisting of BaseUnit + BU cover, 30 mm
BaseUnit + BU cover, 15 mm
4 3DI/LC module 8 3DI/LC module
4
6 ET 200SP motor starter F-DI and 9 Infeed bus cover
5 Infeed bus cover ET 200SP motor starter

Motor starter, BaseUnit, fan and 3DI/LC control module 3RK1308 motor starter in the ET 200SP I/O system
8

More information
Homepage, see www.siemens.com/sirius-motor-starter-et200sp Industry Online Support (SIOS) topic page with information on
Industry Mall, see www.siemens.com/product?3RK1308 the planning and operating phases, see
https://support.industry.siemens.com/cs/ww/en/view/109792664
TIA Selection Tool, see www.siemens.com/TST
Further components in the ET 200SP I/O system:
Decision support for motor start – Starting and operating three-phase • Catalog ST 70
asynchronous motors efficiently, see www.siemens.com/motorstart-guide • Homepage, see www.siemens.com/et200sp

ET 200SP motor starters


ET 200SP is a scalable and extremely flexible modular • All supply voltages connected only once, i.e. when modules
I/O system with degree of protection IP20. are added, they are automatically connected to the next
module
As I/O modules, the ET 200SP motor starters are an integral part
of this I/O system. They are switching and protection devices for • Hot swapping is permissible
1- and 3-phase loads and are available as direct-on-line or • Digital inputs can optionally be used via a 3DI/LC module
reversing starters. • Control of the motor starter from the control system and of
the diagnostics status via the cyclic process image
• Diagnostics capability for active monitoring of the switching
and protection functions
• The signal states in the process image of the motor starter
provide information about protective devices (short circuit
Video: SIMATIC ET 200SP motor starter - Flexible, powerful,
or overload), the switching states of the motor starter,
space-saving and system faults.
Starter kit
Basic functionality
The 3RK1908-1SK00 starter kit is a favorably priced complete
All versions of the ET 200SP motor starter feature the following package for switching and monitoring motors in the ET 200SP
functionality: system, see page 8/102.
• Fully pre-wired motor starters for switching and protecting any
AC loads up to 5.5 kW from 48 V AC to 500 V AC It contains:
• Disconnection possible via fail-safe motor starters up to SIL 3 • A 3RK1308-0BC00-0CP0 reversing starter (0.9 to 3 A)
and PL e Cat. 4 • A 3RK1908-0AP00-0AP0 BaseUnit with 500 V and
• With self-assembling 32 A power bus, i.e. the load voltage is 24 V AC/DC infeed
only fed in once for a group of motor starters • An EMC distance module (consisting of
6ES7193-6BP00-0BA0 BaseUnit plus
6ES7133-6CV15-1AM0 BU cover 15 mm)

8/94 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

ET 200SP motor starters


Use of fan BaseUnits for motor starters
For motor starters with a 12 A rated current,
the 3RW4928-8VB00 fan is included in the scope of supply. 1 24 V and 500 V DC
This fan can also be ordered as an option for motor starters with 2 500 V AC
lower rated currents, if the boundary conditions demand this.
3 24 V DC
For information on the ambient conditions for the use of motor
starters, see chapter "Product features" in the Equipment 4 without infeed
Manual. 5 3RK1908-0AP00-0EP0
(not shown here)
Designing interference-free motor starters
6 3RK1908-0AP00-0FP0
For interference-free operation of the ET 200SP station in (not shown here)
accordance with IEC 60947-4-2 standard, use a dummy module

IC01_00535b
before the first motor starter. The dummy module consists of the 7 500 V AC
6ES7193-6BP00-0BA0 or 6ES7193-6BP00-0DA0 BaseUnit and with F-DI infeed
the 6ES7133-6CV15-1AM0 BU cover 15 mm. 8 500 V AC
1 2 3 4 7 8 9 10
with F-DI loop-through
The 15 mm BU cover protects the plug contacts of the BaseUnit
against dirt. 9 without infeed
with F-DI loop-through
Electromechanical switching devices in series with hybrid motor
starters 10 without infeed
with F-DI infeed
Switching an inductive load - in particular of motors <1 kW with
high inductance - with an electromechanical switching device View of the BaseUnit infeeds for the motor starters
(e.g. contactor) can cause high and steep voltage edges.
BaseUnits are components used for mounting the
The resulting faults/damage can be prevented by first ET 200SP I/O modules.
disconnecting with the hybrid motor starter or by using
EMC suppression modules: The self-assembling voltage buses integrated into the BaseUnits
reduce wiring outlay to the single infeed (both of auxiliary and
• For 3RT2916-1P.. EMC suppression modules for direct load voltage).
mounting on the contactor, see page 3/113
• For motor suppression modules that are fitted in the main All modules following on the right are automatically supplied
circuit, see page 8/102 upon plugging the BaseUnits together, if BaseUnits are inserted
with a loop-through.

8
Note:
The rugged design and keyed connection technology enables
For more information, see use in harsh industrial conditions.
https://support.industry.siemens.com/cs/ww/en/view/109758696.
The BaseUnits are available with various infeeds for the motor
3DI/LC control module starters.

3DI/LC control module


This is a digital input module with three inputs for local motor
starter functions such as "manual local control", "implementation
of fast inputs" or "end position disconnection". For a list of all the
functions permitted by the 3DI/LC module, see chapter
"Functions" in the Equipment Manual.
The module is plugged into the front of the motor starter from
which it is supplied with a 24 V DC operational voltage.

Siemens IC 10 · 2023 8/95


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

ET 200SP motor starters


Article number schemes

Product versions Article number


Motor starters 3RK1308 – 0 @ @ 0 0 – 0 C P 0
Product function Direct-on-line starters A For motor standard output 0.09 ... 5.5 kW1)
Reversing starters B For motor standard output 0.09 ... 5.5 kW1)
Fail-safe direct-on-line starters C For motor standard output 0.09 ... 5.5 kW1)
Fail-safe reversing starters D For motor standard output 0.09 ... 5.5 kW1)
Current range 0.1 ... 0.4 A A Maximum current-carrying capacity when starting 4 A
0.3 ... 1 A B Maximum current-carrying capacity when starting 10 A
0.9 ... 3 A C Maximum current-carrying capacity when starting 30 A
2.8 ... 9 A D Maximum current-carrying capacity when starting 90 A
4 ... 12 A E Including fan (3RW4928-8VB00),
maximum current-carrying capacity when starting 100 A
Example 3RK1308 – 0 A D 0 0 – 0 C P 0
1) For standard motors: 1-phase or 3-phase asynchronous motors, 1-phase
AC motors, 1-phase asynchronous motors, at 400 V AC and 500 V AC;
the actual starting and rated data of the motor to be protected must be
considered when selecting the units.

Product versions Article number


BaseUnit 3RK1908 – 0 A P 0 0 – 0 @ P 0
BU infeed 24 V DC and 500 V AC A
24 V DC B
500 V AC C
Without infeed D
500 V AC G With F-DI infeed
500 V AC H With F-DI loop-through
Without infeed J With F-DI loop-through
Without infeed K With F-DI infeed
8

Example 3RK1908 – 0 A P 0 0 – 0 A P 0

Note:
The article number schemes show an overview of product For your orders, please use the article numbers quoted in
versions for better understanding of the logic behind the the selection and ordering data.
article numbers.

■ Benefits
The ET 200SP motor starters offer a number of advantages: • The ET 200SP motor starters can be used with highly efficient
• Fully integrated into the ET 200SP I/O system (including IE3 and IE4 motors, see Application Manual.
TIA Selection Tool and TIA Portal) Take the current characteristics of the connected motor
and motor starter into account when dimensioning.
• High degree of flexibility when it comes to safety applications In addition to the rated current, the maximum permissible
via SIMATIC F-CPU or 3SK safety relays up to SIL 3 and current range of the motor starter and the ratio of the rated
PL e Cat. 4. current to the starting current of the motor are relevant.
• Simple, integrated current value transmission For more information, see page 1/8.
• Extensive parameterization by means of TIA Portal Standards and approvals
• Increase of plant availability through fast replacement of units • IEC/EN 60947-4-2
(easy mounting and plug-in technology)
• UL 60947-4-2
• Greater endurance and reduced heat losses thanks to hybrid
technology • CSA
• Less space required in the control cabinet (20 to 80%) • ATEX
as a result of greater functional density (direct-on-line and • IEC 62061: SIL 3
reversing starters in same width) • ISO 13849-1: PL e
• Extensive diagnostics and information for preventive • CCC approval for China
maintenance
• Parameterizable inputs via 3DI/LC control module
• Less wiring and testing required as a result of integrating
several functions into a single device
• Lower overheads for stock keeping and configuration as
a result of the wide setting range of the electronic overload
release (up to 1:3)
• Technology has lower inherent power losses than speed-
controlled drive systems, so that less cooling (and smaller
footprint) are possible

8/96 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

ET 200SP motor starters

■ Application
The ET 200SP motor starters are suitable for the following • Track switching and lifting table control in conveyor systems:
applications: Track switches can be implemented by means of the quick
• Switching and monitoring of stop function and lifting table controls by means of the
- 3-phase motors with overload and short-circuit protection "immediate end position disconnection" function without
(e.g. 400 V asynchronous motors for secondary drives in any laborious programming.
conveyor systems) • Safe isolation of drive from main power supply:
- 1-phase motors with overload and short-circuit protection The isolating functions in accordance with IEC 60947-1
(e.g. 230 V motors for pump applications) offer protection against inadvertent activation during plant
- Resistive loads by means of current value and diagnostics maintenance.
via the maintenance function (e.g. for heaters)
Motor starters in the process industry
• Plant monitoring and energy management in conveyor
systems: For the ET 200SP motor starters, special 3RK1908-0AP00-0.H0
By means of the phase asymmetry and zero current detection BaseUnits are available that enable the devices to also be used
during current measurement, drive belt monitoring and in the ET 200SP HA I/O system. This is typically used in process
blocking monitoring are possible, for example. engineering applications.
For more information, see https://mall.industry.siemens.com/
mall/ww/en/Catalog/Products/10398144?tree=CatalogTree.

■ Technical specifications
More information
Industry Mall, see www.siemens.com/product?3RK1308 FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/21800/faq
Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/109479973

ET 200SP motor starters


Article number 3RK1308- 3RK1308- 3RK1308- 3RK1308- 3RK1308-
0.A00-0CP0 0.B00-0CP0 0.C00-0CP0 0.D00-0CP0 0.E00-0CP0
Product category Motor starters

8
General technical specifications
Width x height x depth mm 30 x 142 x 150
H

Design of the switching contact Hybrid


Design of the motor protection Electronic
Installation altitude at height above sea level, m 4 000, derating, see Manual
maximum
Mounting position Vertical, horizontal, (observe derating)
Type of mounting Can be plugged into BaseUnit
Ambient temperature
• During operation °C -25 ... +60
• During transport °C -40 ... +70
• During storage °C -40 ... +70
Relative humidity during operation % 10 ... 95
Vibration resistance 15 mm up to 6 Hz; 2 g up to 500 Hz
Shock resistance 6 g/11 ms
Degree of protection IP on the front IP20
according to IEC 60529
Touch protection on the front Finger-safe
according to IEC 60529
Type of coordination 1
Electrical specifications
Supply voltage at DC rated value V 24
Operational power for AC-53a at 400 V rated value kW 0.12 0.25 1.1 4 5.5
Operating frequency, rated value Hz 50 ... 60
Ultimate short-circuit current breaking capacity (Icu)
• At 400 V rated value kA 55
• At 500 V rated value kA 55
Adjustable current response value of the A 0.1 ... 0.4 0.3 ... 1 0.9 ... 3 2.8 ... 9 4 ... 12
inverse-time delayed overload release
Max. current-carrying capacity on starting A 4 10 30 90 100
Max. permissible voltage for protective V 500
separation between main and auxiliary circuit
Insulation voltage, rated value V 500
Trip class CLASS OFF/5/10 can be set

Siemens IC 10 · 2023 8/97


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

ET 200SP motor starters


BaseUnits for motor starters

Article number 3RK1908-0AP00-0AP0 3RK1908-0AP00-0BP0 3RK1908-0AP00-0CP0 3RK1908-0AP00-0DP0


3RK1908-0AP00-0GP0 3RK1908-0AP00-0JP0
3RK1908-0AP00-0HP0 3RK1908-0AP00-0KP0
Product designation BaseUnit
General technical
specifications
Width x height x depth mm 30 x 215 x 75
H

Ambient temperature
• During operation °C -25 ... +60
• During transport °C -40 ... +70
• During storage °C -40 ... +70
Degree of protection IP IP20
on the front
according to IEC 60529
Touch protection on Finger-safe
the front
according to IEC 60529
Connections/terminals
Type of connectable
conductor cross-sections
• At the inputs for supply
voltage
- Solid 1 x 0.5 ... 2.5 mm2 --
- Finely stranded with end 1 x 0.5 ... 2.5 mm2 --
sleeve
- Finely stranded without 1 x 0.5 ... 2.5 mm2 --
end sleeve
- Solid for AWG cables 1 x 20 ... 12 --
8

• For infeed
- Solid 1 x 1 ... 6 mm2 -- 1 x 1 ... 6 mm2 --
- Finely stranded with end 1 x 1 ... 6 mm2 -- 1 x 1 ... 6 mm2 --
sleeve
- Finely stranded without 1 x 1 ... 6 mm2 -- 1 x 1 ... 6 mm2 --
end sleeve
- For AWG cables 1 x 18 ... 10 -- 1 x 18 ... 10 --
• For load-side outgoing
feeder
- Solid 1 x 0.5 ... 2.5 mm2
- Finely stranded with end 1 x 0.5 ... 2.5 mm2
sleeve
- Finely stranded without 1 x 0.5 ... 2.5 mm2
end sleeve
- For AWG cables 1 x 20 ... 12
Type of electrical Spring-loaded terminals (push-in)
connection for auxiliary
and control circuits
Miscellaneous
Type of screwdriver tip Slotted
Size of screwdriver tip Standard screwdriver 0.6 mm x 3.5 mm

8/98 Siemens IC 10 · 2023


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

ET 200SP motor starters


3DI/LC control module
Article number 3RK1908-1AA00-0BP0
Product designation 3DI/LC control module
General technical specifications
Width x height x depth mm 30 x 54.5 x 42.3
H

Product version Accessories


Number of digital inputs 4
Installation altitude at height above sea level, m 2 000
maximum
Mounting position Vertical, horizontal, flat
Type of mounting Can be plugged onto motor starter
Ambient temperature
• During operation °C -25 ... +60
• During transport °C -40 ... +70
• During storage °C -40 ... +70
Connections/terminals
Connectable conductor cross-section for
auxiliary contacts
• Solid or stranded mm² 0.2 ... 1.5
• Finely stranded with end sleeve mm² 0.25 ... 1.5
• Finely stranded without end sleeve mm² 0.2 ... 1.5
AWG number as coded connectable conductor 24 ... 16
cross-section for auxiliary contacts
Type of electrical connection for auxiliary and Spring-loaded terminals (push-in)
control circuits
Electrical specifications
Type of voltage of the control supply voltage DC

8
Control supply voltage at DC rated value V 20.4 ... 28.8
Miscellaneous
Type of screwdriver tip Slotted
Size of screwdriver tip Standard screwdriver 0.6 mm x 3.5 mm

Siemens IC 10 · 2023 8/99


© Siemens 2023

Load feeders and motor starters for use in the control cabinet

ET 200SP motor starters IE3 ready IE4 ready IE3/IE4 ready

■ Selection and ordering data


Adjustable current response Max. current-carrying Article No. Price PU PS* PG
value of the inverse-time capacity on starting per PU (UNIT,
delayed overload release SET, M)
A A
Motor starters
Direct-on-line starters
0.1 ... 0.4 4 3RK1308-0AA00-0CP0 1 1 unit 42D
0.3 ... 1 10 3RK1308-0AB00-0CP0 1 1 unit 42D
0.9 ... 3 30 3RK1308-0AC00-0CP0 1 1 unit 42D
2.8 ... 9 90 3RK1308-0AD00-0CP0 1 1 unit 42D
4 ... 12 100 3RK1308-0AE00-0CP0 1 1 unit 42D

3RK1308-0AB00-0CP0
Reversing starters
0.1 ... 0.4 4 3RK1308-0BA00-0CP0 1 1 unit 42D
0.3 ... 1 10 3RK1308-0BB00-0CP0 1 1 unit 42D
0.9 ... 3 30 3RK1308-0BC00-0CP0 1 1 unit 42D
2.8 ... 9 90 3RK1308-0BD00-0CP0 1 1 unit 42D
4 ... 12 100 3RK1308-0BE00-0CP0 1 1 unit 42D

3RK1308-0BB00-0CP0
Fail-safe direct-on-line starters
0.1 ... 0.4 4 3RK1308-0CA00-0CP0 1 1 unit 42D
8

0.3 ... 1 10 3RK1308-0CB00-0CP0 1 1 unit 42D


0.9 ... 3 30 3RK1308-0CC00-0CP0 1 1 unit 42D
2.8 ... 9 90 3RK1308-0CD00-0CP0 1 1 unit 42D
4 ... 12 100 3RK1308-0CE00-0CP0 1 1 unit 42D

3RK1308-0CE00-0CP0
Fail-safe reversing starters
0.1 ... 0.4 4 3RK1308-0DA00-0CP0 1 1 unit 42D
0.3 ... 1 10 3RK1308-0DB00-0CP0 1 1 unit 42D
0.9 ... 3 30 3RK1308-0DC00-0CP0 1 1 unit 42D
2.8 ... 9 90 3RK1308-0DD00-0CP0 1 1 unit 42D
4 ... 12 100 3RK1308-0DE00-0CP0 1 1 unit 42D

3RK1308-0DE00-0CP0

* You can order this quantity or a multiple thereof.


8/100 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Load feeders and motor starters for use in the control cabinet

ET 200SP motor starters

Product
Product version
version Operational Supply Push-in terminals PU PS* PG
voltage voltage (UNIT,
of AC of DC Article No. Price SET, M)
infeed infeed per PU
V V
BaseUnits1)
For motor starters
• With AC/DC infeed 500 24 3RK1908-0AP00-0AP0 1 1 unit 42D
• With DC infeed -- 24 3RK1908-0AP00-0BP0 1 1 unit 42D
• With AC infeed 500 -- 3RK1908-0AP00-0CP0 1 1 unit 42D
• Without infeed -- -- 3RK1908-0AP00-0DP0 1 1 unit 42D
For fail-safe motor starters
• With AC infeed, 500 -- 3RK1908-0AP00-0GP0 1 1 unit 42D
with F-DI infeed
3RK1908-0AP00-0AP0 • With AC infeed, 500 -- 3RK1908-0AP00-0HP0 1 1 unit 42D
with F-DI loop-through
• Without AC/DC infeed, -- -- 3RK1908-0AP00-0JP0 1 1 unit 42D
with F-DI loop-through
• Without AC/DC infeed, -- -- 3RK1908-0AP00-0KP0 1 1 unit 42D
with F-DI infeed
1)
The voltage is looped-through from BaseUnits with infeed to subsequent
BaseUnits without infeed.

Product
Product version
version Supply voltage Loop through Push-in terminals PU PS* PG
at DC rated the potential (UNIT,
value group from Article No. Price SET, M)
the left per PU
V
BaseUnits
For dummy modules

8
• Dark, looping through 24 Yes 6ES7193-6BP00-0BA0 1 1 unit 255
the potential group
• Light, opening a new 24 No 6ES7193-6BP00-0DA0 1 1 unit 255
potential group

6ES7193-6BP00-0BA0

Control supply voltage Product function Push-in terminals PU PS* PG


at DC rated value (UNIT,
local control digital inputs Article No. Price SET, M)
parameterizable per PU
V
3DI/LC control module
20.4 ... 28.8 Yes Yes 3RK1908-1AA00-0BP0 1 1 unit 42D

3RK1908-1AA00-0BP0

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 8/101
© Siemens 2023

Load feeders and motor starters for use in the control cabinet

ET 200SP motor starters

Product designation Product version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)
Accessories
BU cover 15 mm For BaseUnits 6ES7133-6CV15-1AM0 1 5 units 255
Type A0 or A1

6ES7133-6CV15-1AM0
BU cover 30 mm For protection of 3RK1908-1CA00-0BP0 1 1 unit 42D
empty slots, 30 mm

3RK1908-1CA00-0BP0
Covers For ET 200SP 3RK1908-1DA00-2BP0 1 1 unit 42D
Infeed bus
(1 bag containing
10 covers)

3RK1908-1DA00-2BP0
Additional mounting Mechanical, 3RK1908-1EA00-1BP0 1 1 unit 42D
8

base unit for ET 200SP


(1 bag containing
5 additional mounting
base units)
3RK1908-1EA00-1BP0
Fan Can be used for 3RW4928-8VB00 1 1 unit 42G
3RK1308

3RW4928-8VB00
Motor suppression module
• Square 3RK1911-6EA00 1 1 unit 42D

3RK1911-6EA00
• Round 3RK1911-6EB00 1 1 unit 42D

3RK1911-6EB00
Starter kit Consists of 3RK1908-1SK00 1 1 unit 42D
3RK1308-0BC00-0CP0
reversing starter
(0.9 ... 3 A),
3RK1908-0AP00-0AP0
BaseUnit with 500 V and
24 V AC/DC infeed, and
EMC distance module
(consisting of
6ES7193-6BP00-0BA0
BaseUnit plus
6ES7133-6CV15-1AM0
BU cover 15 mm)
3RK1908-1SK00

* You can order this quantity or a multiple thereof.


8/102 Siemens IC 10 · 2023 Illustrations are approximate
9
© Siemens 2023

Motor starters for use in the field, high degree of protection

Price groups
PG 241, 250, 368, 41J, 42C, 42D, 5K1,
5K2

9/2 Introduction

ET 200pro motor starters


9/3 General data
9/8 Standard motor starters
9/9 High Feature motor starters
9/10 ET 200pro isolator modules
ET 200pro Safety motor starters
Solution PROFIsafe
9/11 - Safety modules PROFIsafe
9/13 Accessories for ET 200pro motor
starters
Software
9/18 Motor Starter ES

SIRIUS M200D motor starters


9/19 General data
M200D motor starters for AS-Interface
9/21 General data
9/25 M200D Basic motor starters
9/26 M200D Standard motor starters
M200D motor starters for
PROFIBUS/PROFINET
9/27 General data
9/33 Communications modules,
motor starter modules

9
Software
9/34 Motor Starter ES
Accessories
9/35 For all M200D motor starters
9/40 For M200D motor starters for
AS-Interface
9/42 For M200D motor starters for PROFIBUS
9/43 For M200D motor starters for PROFINET

Siemens IC 10 · 2023
© Siemens 2023

Motor starters for use in the field, high degree of protection

Introduction

■ Overview
Flexible and cost-efficient distributed starter solutions Decision support for motor start – Starting and operating
three-phase asynchronous motors efficiently
Be it their high degree of protection, compact design or
integrated multifunctionality – our motor starters and soft starters
for use in the field are ideal for realizing distributed drive
solutions. The modular concepts, distributed power supply
and integrated safety technology of our portfolio for a high
degree of protection consistently supports current trends in
drive technology.

Decision support tool for motor start


This tool guides you to the optimum individual drive solution
via a short query about the application.
Based on this solution approach, you will then be directed to
the right product configurator for selecting the appropriate
products, see
www.siemens.com/motorstart-guide.
9

3RK1304 3RK1315
Type Page
ET 200pro motor starters
Motor starters in the SIMATIC ET 200pro I/O system up to 5.5 kW
Standard motor starters 3RK1304 9/8
High Feature motor starters 3RK1304 9/9
ET 200pro isolator modules • With switch disconnector function for safe disconnection 3RK1304 9/10
Safety modules PROFIsafe • F-Switch PROFIsafe 6ES7148 9/11
• 400 V disconnecting module 3RK1304 9/11
Accessories for ET 200pro motor starters • Incoming power supply, power loop-through connection on the field device, 3RK19 9/13
motor cable, power bus with power terminal connectors
ET 200pro – interface modules • For communication with PROFIBUS, PROFINET and IWLAN 6ES71 ST 70
ET 200pro – CPUs • Standard CPUs, fail-safe CPUs 6ES71 ST 70
ET 200pro – I/O modules • Digital/analog expansion modules, fail-safe expansion modules, 6ES71 ST 70
power modules, ET 200pro pneumatic interfaces
ET 200pro PS • Stabilized power supplies 6ES7148 ST 70
ET 200pro FC-2 frequency converters 6SL35 D 31.2
ET 200pro add-on products • Modules for EtherNet/IP ZNX:EIP ST 70
SIRIUS M200D motor starters
Distributed motor starters up to 5.5 kW
M200D AS-i Basic motor starters 3RK1315 9/25
M200D AS-i Standard motor starters 3RK1325 9/26
M200D communications modules for PROFIBUS 3RK1305 9/33
M200D communications modules for PROFINET 3RK1335 9/33
M200D motor starter modules 3RK1395 9/33
Accessories • Incoming power supply, motor cable, power bus with power terminal connectors 3RK1911 9/37
• Motor control with I/O communication 3RK1902 9/39
• Motor control with AS-i communication 3RK1902 9/40
• Motor control with PROFIBUS 3RK1902 9/42
• Motor control with PROFINET 3RK1902 9/43

9/2 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
General data

■ Overview
ET 200pro motor starters in ET 200pro I/O system
More information
SIMATIC ET 200pro is the modular I/O system with high
degree of protection IP65/66/67 for local, cabinet-free use. Homepage, see www.siemens.com/sirius-motor-starter-et200pro
The ET 200pro motor starters with the high degree of protection Industry Mall, see www.siemens.com/product?ET200pro
IP65 are an integral part of ET 200pro. Decision support for motor start – Starting and operating three-phase
asynchronous motors efficiently, see www.siemens.com/motorstart-guide
Further components in the ET 200pro distributed I/O system:
• Interface modules, central processing units, I/O modules, ET 200pro PS,
see Catalog ST 70
• ET 200pro FC-2 frequency converters, see Catalog D 31.2

ET 200pro isolator modules (see page 9/10)


The isolator module with switch disconnector function is used
for safe disconnection of the 400 V operational voltage during
repair work in the plant and provides an integrated group fusing
function (i.e. additional group short-circuit protection for all
subsequently supplied motor starters).
Depending on the power distribution concept, all stations can
be equipped with an isolator module as an option.
Safety applications
Safety Solution PROFIsafe (see page 9/11)
With the Safety modules PROFIsafe
• F-Switch and
ET 200pro motor starter: Isolator module, Standard starter and • 400 V disconnecting module
High Feature starter mounted on a wide module rack with an appropriate connection, safety levels SIL 3 (according
ET 200pro motor starters (see pages 9/8 and 9/9) to IEC 62061) or PL e (according to ISO 13849-1) can also be
reached.
• Only two versions up to 5.5 kW
• All settings can be parameterized by bus Functionality
• Comprehensive diagnostic messages With the ET 200pro motor starters, any AC loads can be
• Support for PROFIenergy protected and switched.
• Overload can be acknowledged by Remote RESET The ET 200pro motor starters are available both with mechanical
as well as electronic contacts.

9
• Current asymmetry monitoring
• Stall protection The ET 200pro electromechanical starters are offered as direct-
on-line starters (DSe) and reversing starters (RSe) as Standard
• EMERGENCY START function on overload and High Feature versions. There are device versions with or
• Current value transmission by bus without control for externally supplied brakes with 400 V AC.
• Current limit monitoring Compared with the Standard motor starters, the High Feature,
• Full support of acyclic services mechanical motor starter also has:
• Direct-on-line or reversing starters • Four digital inputs
• Power bus connection can be plugged in using Han Q4/2 • Advanced parameterization options
plug-in connectors
The ET 200pro electronic starters are offered as direct-on-line
• Motor feeder with Han Q8/0 connector starters (sDSSte/sDSte) and reversing starters (sRSSte/sRSte)
• Conductor cross-sections up to 6 x 4 mm² in the High Feature version.
• 25 A per segment (power looped through using jumper plug) Compared with the High Feature mechanical motor starters,
• In the Standard and High Feature versions (with 4 DI on-board) the High Feature electronic motor starter also has:
• Electromechanical switching and electronic switching • Soft starting and smooth ramp-down function
• Electronic starter for direct activation or with integrated soft • Deactivated soft start function as an electronic starter for
starter function applications with a high switching frequency
• Supplied with 400 V AC brake contact as an option • Advanced parameterization options
• Temperature sensor can be connected
(Thermoclick or PTC type A)
• Provision of the motor current in PROFIenergy format to
higher-level systems, motor current shutdown in dead times
using PROFIenergy

Siemens IC 10 · 2023 9/3


© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
General data
As a result of the protection concept with solid-state overload Voltage data
evaluation and the use of SIRIUS switching devices, size S00,
additional advantages are realized on the Standard and High The specifications for 3-phase systems according to
Feature motor starters – advantages that soon make themselves IEC 60947-4-1 apply for the following line system configurations:
.

positively felt particularly in manufacturing processes with high Voltage Ue Line system configurations
plant stoppage costs:
Three-phase Three-phase
• Configuration is made easier by the fine modular structure four-wire systems three-wire systems
with ET 200pro. When using the ET 200pro motor starters,
the parts list per load feeder is reduced to two main items:
the bus module and the motor starter. This makes the
ET 200pro ideal for modular machine concepts or solutions

IC01_00703
for conveyor systems and in machine-tool construction.

IC01_00709
• Expansions are easily possible through the subsequent
adding of modules. The innovative plug-in technology also
does away with the wiring needed up to now. Through the hot V V V
swapping function (disconnection and connection during 230 -- 230
operation) a motor starter can be replaced within seconds if
400 230/400 400
necessary, without having to shut down the ET 200pro station
and with it the process in the plant. The motor starters are 440 260/440 440
therefore recommendable in particular for applications with 500 -- 500
special demands on availability. Storage costs are also -- Not specified
optimized by the low level of variance (two units up to 5.5 kW).
• With four locally acting inputs available on the High Feature
motor starter it is possible to realize autonomous special
functions which work independently of the bus and the higher-
level control system, e.g. as a quick stop on gate valve
controls or limit position disconnectors. In parallel with this,
the states of these inputs are signaled to the control system.

Article number schemes

Product versions Article number


Motor starters 3RK1304 – 5 @ S @ 0 – @ A A @
Setting range 0.15 ... 2.0 A K
1.5 ... 12 A L
Product function Direct-on-line starters DSe 4 4 Standard
9

Reversing starters RSe 4 5 Standard


Direct-on-line starters DSe 4 2 High Feature
Reversing starters RSe 4 3 High Feature
Direct-on-line starters 7 2 High Feature
sDSSte/sDSte
Reversing starters sDSSte/sDSte 7 3 High Feature
Inputs/outputs Without brake output 0
With brake output 3 400 V AC, with High Feature + 4 inputs
Example 3RK1304 – 5 K S 4 0 – 4 A A 0

Product versions Article number


Modules 3RK1304 – 0 H S 0 0 – @ A A 0
Product function Isolator modules 6
400 V disconnecting modules 8 Safety modules PROFIsafe
Example 3RK1304 – 0 H S 0 0 – 6 A A 0

Note:
The article number schemes show an overview of product
versions for better understanding of the logic behind the article
numbers.
For your orders, please use the article numbers quoted in the
selection and ordering data.

9/4 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
General data

Type Standard motor High Feature motor starters


starters
Technology designation1) DSe, RSe DSe, RSe sDSSte, sDSte,
sRSSte, sRSte
Device functions (firmware features)
Parameterizable rated operational current ✓
Integrated short-circuit protection ✓
Parameterizable current limit values -- ✓ 2 limit values
Parameterizable response in case of current limit violation -- ✓
Zero current monitoring ✓
Parameterizable response in case of zero current violation ✓
Parameterizable current asymmetry limit % -- Fixed limit value ✓ 30 ... 60 x Ie
(30 x Ie)
Parameterizable response in case of asymmetry limit violation ✓
Motor blocking monitoring -- ✓
Parameterizable blocking current limit % -- ✓ 150 ... 1 000 x Ie
Parameterizable blocking time limit s -- ✓ 1 ... 5
Current value transmission ✓
Group warning diagnostics -- ✓ Parameterizable
Group diagnostics ✓ Parameterizable
EMERGENCY START ✓
Digital inputs -- ✓ 4 inputs
• Parameterizable input signal -- ✓ Latching/non-latching
• Parameterizable input level -- ✓ NC/NO contacts
• Parameterizable input signal delay ms -- ✓ 10 ... 80
• Parameterizable input signal extension ms -- ✓ 0 ... 200
• Parameterizable input control actions -- ✓ 12 different actions
Brake output (400 V AC) ✓ Order option
Parameterizable brake enabling delay s ✓ -2.5 ... +2.5
Parameterizable holding time of the brake during stopping s ✓ 0 ... 25
Parameterizable startup type -- ✓
Parameterizable ramp-down time -- ✓
Parameterizable starting voltage -- ✓
Parameterizable stopping voltage -- ✓

9
Local device interface ✓
Firmware update ✓ By specialists
Thermal motor model ✓
Parameterizable trip class -- CLASS 10 fixed ✓ CLASS 5, 10, 15, 20
Parameterizable response in case of overload of thermal -- ✓ 3 possible states
motor model
Advance warning limit for motor heating % -- ✓ Parameterizable 0 ... 95
Advance warning limit time-related trip reserve s -- ✓ Parameterizable 0 ... 500
Parameterizable recovery time min -- ✓ 1 ... 30
Parameterizable protection against voltage failure -- Permanently ✓
integrated
Reversing start function ✓ Order option
Parameterizable interlock time for reversing starters -- 150 ms fixed ✓ 0 ... 60 s
Integrated logbook functions ✓ 3 device logbooks
Integrated statistics data memory ✓
Parameterizable response in case of CPU/master stop ✓
PROFIenergy profile support
• Disconnection of the motor current during dead times ✓
• Measured motor current values ✓
Device indications
• Group fault SF LED (red)
• Switching state STATE LED (red, yellow, green)
• Device status DEVICE LED (red, yellow, green)
• Digital inputs -- IN 1 ... IN 4, LED
✓ Function available
-- Function not available
1)
DS .... Direct-on-line starters
RS .... Reversing starters
DSS .. Direct-on-line soft starters
RSS .. Reversing soft starters
e ....... Electronic motor protection
te ...... Full motor protection (thermal + electronic)
s ....... Electronic switching with semiconductor.

Siemens IC 10 · 2023 9/5


© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
General data

■ Benefits
ET 200pro motor starters provide the following advantages: • Extensive diagnostics and information for preventive
• High flexibility thanks to a modular and compact design maintenance
• Little variance among all motor starter versions (two units up • Parameterizable inputs for local control functions
to 5.5 kW) (High Feature)
• Extensive parameterization using STEP 7 HW Config • Cabinet-free design thanks to high degree of protection IP65
• Increase of plant availability through fast replacement of units
(easy mounting and plug-in technology)

■ Application
The SIMATIC ET 200pro motor starters are ideal for the use Use of ET 200pro motor starters in conjunction with
of several spatially concentrated distributed drive solutions in IE3 and IE4 motors
which several motors, or digital or analog sensors and actuators
are addressed from a distributed station. They are perfectly Note:
suited for protecting and switching any AC loads. For the use of ET 200pro motor starters in conjunction with highly
efficient IE3 and IE4 motors, please observe the information on
Application areas dimensioning and configuring, see Application Manual.
The SIMATIC ET 200pro motor starters are suitable for numerous For more information, see page 1/8.
sectors of industry, e.g. machinery and plant engineering or
conveying applications.
9

9/6 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
General data

■ Technical specifications
More information
Equipment Manual, see Notes on security:
https://support.industry.siemens.com/cs/ww/en/view/22332388 System networking requires suitable protective measures (including
network segmentation for IT security) in order to ensure safe plant operation.
For more information on the subject of Industrial Security, see
www.siemens.com/industrialsecurity.

Type Standard motor starters High Feature motor starters


Mechanical switching Mechanical switching Electronic switching
without inputs with inputs with inputs and soft
starter function
Technology designation1) DSe, RSe DSe, RSe sDSSte, sDSte,
sRSSte, sRSte
Mechanics and environment
Motor starters or modules that can be connected to ET 200pro max. 8
With width of 110 mm
Mounting dimensions (W x H x D)
• Direct-on-line starters and reversing starters mm 110 x 230 x 150 110 x 230 x 160
Permissible ambient temperature
• During operation °C -25 ... +55, from +40 with derating
• During storage °C -40 ... +70
Permissible mounting position Vertical, horizontal
Vibration resistance according to IEC 60068, Part 2-6 g 2
Shock resistance according to IEC 60068, Part 2-27 g/ms Half-sine 15/11
Degree of protection IP65
Pollution degree 3, IEC 60664 (IEC 61131)
Electrical specifications
Power consumption at 24 V DC
• From auxiliary circuit L+/M (U1) mA Approx. 40
• From auxiliary circuit A1/A2 (U2) mA Approx. 200
Rated operational current Ie for power bus A 25
Rated operational voltage Ue V AC 400 (50/60 Hz)
• Approval according to EN 60947-1, Annex N V AC Up to 400 (50/60 Hz) Up to 400 (50/60 Hz)
• Approval according to CSA and UL V AC Up to 600 (50/60 Hz) Up to 480 (50/60 Hz)
Approval

9
• DIN VDE 0106, Part 101 V Up to 400 Up to 480
• CSA and UL approval V Up to 600 Up to 480
Conductor cross-sections
• Incoming power supply mm2 Max. 6 x 4
Touch protection Finger-safe
Rated impulse withstand voltage Uimp kV 6
Rated insulation voltage Ui V 400
Rated operational current Ie for starters
• AC-1/2/3 at 40 °C
- At 400 V A 0.15 ... 2.0/1.5 ... 12.0 0.15 ... 2.0/1.5 ... 12.02)
- At 500 V A 0.15 ... 2.0/1.5 ... 9.0
• AC-4 at 40 °C
- At 400 V A 0.15 ... 2.0/1.5 ... 4.0
Rated short-circuit breaking capacity kA 100 at 400 V
Type of coordination according to IEC 60947-4-1 1
Power of three-phase motors at 400 V kW Max. 5.5 Max. 5.5/43)
Utilization categories AC-1, AC-3, AC-4 AC-53a4) (max. 9 A with
deactivated soft start
function up to CLASS 10)
Protective separation between main and auxiliary circuits V 400, according to EN 60947-1, Annex N
Endurance of contactor
• Mechanical Operating 30 million --
cycles
• Electrical Operating Up to 10 million; depending on the current loading --
cycles (see manual)
Permissible switching frequency Depending on the current loading, motor starting time, and relative ON period
(see manual)
Operating times for 0.85 ... 1.1 x Ue
• Closing delay ms 11 ... 50 --
• Opening delay ms 5 ... 45 --
1) 2)
DS .... Direct-on-line starters If the soft starter control function is deactivated, the permissible rated
RS .... Reversing starters operational current is reduced to 9 A up to CLASS 10.
DSS .. Direct-on-line soft starters 3) With parameterization as electronic starter max. 4 kW.
RSS .. Reversing soft starters 4)
8-hour operation.
e ....... Electronic motor protection
te ...... Full motor protection (thermal + electronic)
s ....... Electronic switching with semiconductor.

Siemens IC 10 · 2023 9/7


© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
Standard motor starters IE3 ready IE4 ready IE3/IE4 ready
AC-3e

■ Overview
The functionality, device functions, and technical specifications
of the Standard motor starter are described in "ET 200pro motor
starters, General data" (see page 9/3 onwards).

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Standard motor starters, mechanical


Motor protection: thermal model
Direct-on-line starters DSe1)
• Without brake output 3RK1304-5@S40-4AA0 1 1 unit 42D
• With brake output 400 V AC 3RK1304-5@S40-4AA3 1 1 unit 42D
Reversing starters RSe1)
• Without brake output 3RK1304-5@S40-5AA0 1 1 unit 42D
• With brake output 400 V AC 3RK1304-5@S40-5AA3 1 1 unit 42D

Setting range Add. price


Rated operational current
DSe Standard • 0.15 ... 2.0 A K None
• 1.5 ... 12.0 A L ✓

✓ = Additional price
1)
Only functions when used together with the backplane bus module and the
wide module rack. The backplane bus module and the wide module rack
must be ordered separately (see "Accessories for ET 200pro motor
starters", page 9/17).
9

* You can order this quantity or a multiple thereof.


9/8 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
AC-3e E3 ready IE4 ready IE3/IE4 ready High Feature motor starters

■ Overview
The functionality, device functions, and technical specifications The High Feature motor starter differs from the Standard
of the High Feature motor starter are described in motor starter in having more parameters and four integrated,
"ET 200pro motor starters, General data" (see page 9/3 onwards). freely-parameterizable digital inputs.

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

High Feature motor starters, mechanical


Motor protection: thermal model
Direct-on-line starters DSe1)
• Without brake output and with 4 inputs 3RK1304-5@S40-2AA0 1 1 unit 42D
• With brake output 400 V AC and 4 inputs 3RK1304-5@S40-2AA3 1 1 unit 42D
Reversing starters RSe1)
• Without brake output and with 4 inputs 3RK1304-5@S40-3AA0 1 1 unit 42D
• With brake output 400 V AC and 4 inputs 3RK1304-5@S40-3AA3 1 1 unit 42D

Setting range Add. price


Rated operational current
RSe High Feature • 0.15 ... 2.0 A None
K
• 1.5 ... 12.0 A L ✓
High Feature motor starters2), electronic
Full motor protection, comprising thermal motor protection and
thermistor motor protection
Direct-on-line starters sDSSte/sDSte1)2)
• Without brake output and with 4 inputs 3RK1304-5@S70-2AA0 1 1 unit 42D
• With brake output 400 V AC and 4 inputs 3RK1304-5@S70-2AA3 1 1 unit 42D
Reversing starters sRSSte/sRSte1)2)
• Without brake output and with 4 inputs 3RK1304-5@S70-3AA0 1 1 unit 42D
• With brake output 400 V AC and 4 inputs 3RK1304-5@S70-3AA3 1 1 unit 42D

Setting range Add. price

9
Rated operational current
sRSSte High Feature • 0.15 ... 2.0 A None
K
• 1.5 ... 12.0 A L ✓
✓ = Additional price
1)
Only functions when used together with the backplane bus module and the
wide module rack. The backplane bus module and the wide module rack
must be ordered separately (see "Accessories for ET 200pro motor
starters", page 9/17).
2)
The electronic motor starters can be used not only as electronic motor
starters with a high level of switching frequency but also as fully fledged
soft starters for soft starting and stopping. The changeover from motor
starter to soft starter takes place through reparameterization in HW Config.
Depending on the setting, this results in the following current ranges:
- Parameterization as electronic motor starter: 0.15 to 2 A and
1.5 to 9 A (4 kW)
- Parameterization as soft starter: 0.15 to 2 A and 1.5 to 12 A (5.5 kW).

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 9/9
© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
ET 200pro isolator modules IE3 ready IE4 ready IE3/IE4 ready

■ Overview
The isolator module with integrated group fusing function The following properties apply to the isolator module:
(i.e. additional group short-circuit protection for all subsequently • Increase of plant availability through fast replacement of units
supplied motor starters) and switch disconnector function is (easy mounting and plug-in technology)
used for safe disconnection of the 400 V operational voltage
during repair work in the plant. • Cabinet-free design thanks to high degree of protection IP65

Depending on the power distribution concept, all stations can be


equipped with an isolator module as an option.

■ Technical specifications
Type Isolator modules Type Isolator modules
General data Degree of protection IP65
Mounting dimensions (W x H x D) Touch protection Finger-safe
• Direct-on-line starters and reversing mm 110 x 230 x 170 Pollution degree 3, IEC 60664 (IEC 61131)
starters
Rated impulse withstand voltage kV 6
Permissible ambient temperature Uimp
• During operation °C -25 ... +55
• During storage °C -40 ... +70 Rated insulation voltage Ui V 400
Permissible mounting position Any Rated operational current Ie
for starters
Vibration resistance according to g 2
IEC 60068, Part 2-6 • AC-1/2/3 at 40 °C
- At 400 V A 25
Shock resistance according to g/ms Half-sine 15/11 - At 500 V A 25
IEC 60068, Part 2-27
Rated short-circuit breaking kA 50 at 400 V
Power consumption capacity
• From auxiliary circuit L+/M (U1) mA Approx. 20
• From auxiliary circuit A1/A2 (U2) -- Type of coordination according to 2
IEC 60947-4-1
Rated operational current Ie for A 25
power bus Protective separation between V 400,
main and auxiliary circuits according to DIN VDE 0106,
Rated operational voltage Ue V 400 Part 101
Approvals according to Device functions
• DIN VDE 0106, Part 101 V Up to 500 • Group diagnostics Yes, parameterizable
• CSA and UL V Up to 600
Device indications
Conductor cross-sections • Group fault SF LED (red)
• Incoming power supply mm2 Max. 6 x 4
9

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

ET 200pro isolator modules, mechanical


Isolator modules1)
Rated operational current 25 A 3RK1304-0HS00-6AA0 1 1 unit 42D

3RK1304-0HS00-6AA0
1)
Only functions when used together with the related 110 mm backplane bus
module and the wide module rack. The backplane bus module and the
wide module rack must be ordered separately (see page 9/17).

* You can order this quantity or a multiple thereof.


9/10 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
ET 200pro Safety motor starters Solution PROFIsafe > Safety modules PROFIsafe

■ Overview
Safety Solution PROFIsafe Functionality
With the Safety modules PROFIsafe The F-Switch PROFIsafe is a fail-safe solid-state module for
• F-Switch and PROFIsafe safety applications. It has two fail-safe inputs and
• 400 V disconnecting module outputs for safe switching of the 24 V supply over backplane
with an appropriate connection, safety levels SIL 3 (according to busbars. In combination with the 400 V disconnecting module,
IEC 62061) or PL e (according to ISO 13849-1) can be reached. fail-safe disconnection of ET 200pro motor starters is possible in
PROFIsafe applications up to SIL 3/PL e.
F-Switch PROFIsafe
400 V disconnecting module
Fail-safe digital inputs/outputs in degrees of protection IP65 to
IP67 for near-machine, cabinet-free use. The 400 V disconnecting module enables the safe
disconnection of an operational voltage of 400 V up to
Fail-safe digital inputs SIL 3/PL e. For operation in a Safety PROFIsafe application
• For the fail-safe reading in of sensor information it functions only in combination with the F-Switch.
(1-/2-channel)
• Including integrated discrepancy evaluation Functionality
for 2v2 signals The 400 V disconnecting module can be used together with
• Internal sensor supplies (incl. testing) available the F-Switch for PROFIsafe safety applications. It contains two
Fail-safe digital outputs contactors connected in series for safety-related disconnection
of the main circuit. The auxiliary circuit supply of the device is
• Three fail-safe PP-switching outputs for safe switching of the provided via a safety power rail in the backplane bus module.
backplane busbars The 400 V disconnecting module can be used in conjunction
The F-Switch is certified up to SIL 3/PL e and has detailed with the
diagnostics. It supports PROFIsafe in PROFIBUS configurations F-Switch for safety applications up to SIL 3/PL e.
as well as in PROFINET configurations.
Note:
Safety characteristics, see page 16/9.

■ Technical specifications
Type 400 V disconnecting module
General data
Mounting dimensions (W x H x D)
• Direct-on-line starters and reversing starters mm 110 x 230 x 150

9
Permissible ambient temperature
• During operation °C -25 ... +55
• During storage °C -40 ... +70
Permissible mounting position Any
Vibration resistance according to IEC 60068, Part 2-6 2g
Shock resistance according to IEC 60068, Part 2-27 Half-sine 15 g/11 ms
Power consumption
• From auxiliary circuit L+/M (U1) mA Approx. 20
• From auxiliary circuit A1/A2 (U2) --
Rated operational current Ie for power bus A 25
Rated operational voltage Ue V 400 (50/60 Hz)
Approval DIN VDE 0106, Part 101 V Up to 500
CSA and UL approval V Up to 600
Conductor cross-sections
Incoming power supply mm2 Max. 6 x 4
Degree of protection IP65
Touch protection Finger-safe
Pollution degree 3, IEC 60664 (IEC 61131)
Rated impulse withstand voltage Uimp kV 6
Rated insulation voltage Ui V 400
Rated operational current Ie for starters
• AC-1/2/3 at 40 °C
- At 400 V A 25
- At 500 V A 25
Rated short-circuit breaking capacity kA 50 at 400 V
Type of coordination according to IEC 60947-4-1 2
Protective separation between main and auxiliary circuits V 400,
according to DIN VDE 0106, Part 101
Operating times for 0.85 ... 1.1 x Ue
• Closing delay ms 25 ... 100
• Opening delay ms 7 ... 10
Device functions
• Group diagnostics Yes, parameterizable
Device indications
• Group fault SF LED (red)

Siemens IC 10 · 2023 9/11


© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
ET 200pro Safety motor starters Solution PROFIsafe > Safety modules PROFIsafe IE3 ready IE4 ready IE3/IE4 ready

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Safety modules PROFIsafe


400 V disconnecting module1)2)
Rated operational current 25 A 3RK1304-0HS00-8AA0 1 1 unit 42D

3RK1304-0HS00-8AA0
F-Switch PROFIsafe
24 V DC, including bus module 6ES7148-4FS00-0AB0 1 1 unit 241
Note:
Connection module must be ordered separately

6ES7148-1FS00-0AB0
Connection module for F-Switch
24 V DC 6ES7194-4DA00-0AA0 1 1 unit 241
1)
The 400 V disconnecting module functions only when used together with
the F-Switch PROFIsafe.
2)
The 400 V disconnecting module functions only when used together with
the backplane bus module and the wide module rack. The backplane bus
module and the wide module rack must be ordered separately (see
"Accessories for ET 200pro motor starters", page 9/17).
9

* You can order this quantity or a multiple thereof.


9/12 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
Accessories for ET 200pro motor starters

■ Overview

RSM RSM

MS MS MS MS

NSA0_00465a

NSA0_00467a
3 4 7
2 9

5 / 6

M M

Basic design of an ET 200pro version with (from the left) connection Infeed on the RSM isolator module
module for IM, interface module for communication (IM), RSM isolator
module, two ET 200pro motor starters (MS), and connections for energy
Legend:
Infeed on the ET 200pro motor starter $ Power feeder plug (see page 9/15)
% Power connection plug (see page 9/15)
& Power jumper plug (see page 9/15)

9
( Motor connection plug (see page 9/15)
) Motor plug (see page 9/15)
MS MS * Motor plug with EMC suppressor circuit (see page 9/15)
+ Power loop-through plug (see page 9/15)
, Power connecting cable (see page 9/15)
- Power connecting cable for isolator module (see page 9/15)
. Motor cable (see page 9/16)
NSA0_00466a

10
8

Infeed on the ET 200pro motor starter

Siemens IC 10 · 2023 9/13


© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
Accessories for ET 200pro motor starters
Power bus Interruption-free thanks to power terminal connectors
The power supply to the field devices (ET 200pro motor starters, In finger-safe connection technology the power T terminal
M200D motor starters) is provided via the power bus, in which connectors and power double-T terminal connectors connect
the power T terminal connectors or power double-T terminal the components of a feeder to the power bus. They ensure
connectors are connected by power bus cables. interruption-free operation, i.e. when the components are
plugged in, the power bus is not interrupted.
Feeders
From the terminal connectors, spur lines with Han Q4/2 plugs
lead to the field devices, from which the motors are supplied with
power via motor connecting cables.

11 Power bus cable (sold by the meter)


12 Power T terminal connector
13 Power double-T terminal connector

11
12 13 13

ET 200pro

M200D M200D

IC01_00230a
9

Motors

Power supply to the motors via the power bus with power T and double-T terminal connectors linked by power bus cables, spur lines to the field devices
(motor starters), and power loop-through connections to the motors via motor connecting cables
Motor control via PROFIBUS Motor control via PROFINET
The interface modules (IM) for PROFIBUS can be combined For connection modules with the relevant accessories, see
with two different connection modules for connecting "Accessories for ET 200pro interface modules" in Catalog ST 70
PROFIBUS DP and the power supply: or the Industry Mall.
• Direct connection with cable gland
• M12, 7/8" connection
- with M12 connecting cable and M12 plugs for data
transmission with PROFIBUS DP
- with 7/8" connecting cable and 7/8" plugs for the power
supply
For connection modules with the relevant accessories, see
"Accessories for ET 200pro interface modules" in Catalog ST 70
or the Industry Mall.

9/14 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
Accessories for ET 200pro motor starters

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Incoming power supply


$ Power feeder plugs
Connector set for energy supply, e.g. for connecting to
T terminal connectors, comprising a coupling enclosure,
straight outgoing feeder (with bracket), pin insert for
HAN Q4/2, incl. gland
• 5 male contacts, 2.5 mm2 3RK1911-2BS60 1 1 unit 42D
• 5 male contacts, 4 mm2 3RK1911-2BS20 1 1 unit 42D
• 5 male contacts, 6 mm2 3RK1911-2BS40 1 1 unit 42D
% Power connection plugs
Connector set for incoming power supply for connection
to ET 200pro motor starters/ET 200pro isolator modules,
comprising a cable-end connector hood, angled
outgoing feeder, female insert for HAN Q4/2, incl. gland
• 5 female contacts, 2.5 mm2 3RK1911-2BE50 1 1 unit 42D
• 5 female contacts, 4 mm2 3RK1911-2BE10 1 1 unit 42D
• 5 female contacts, 6 mm2 3RK1911-2BE30 1 1 unit 42D
, Power connecting cables, assembled at one end
Power connecting cable for ET 200pro motor starters,
open at one end, for HAN Q4/2, angled, 4 x 4 mm2
• Length 1.5 m 3RK1911-0DB13 1 1 unit 42D
• Length 5.0 m 3RK1911-0DB33 1 1 unit 42D
- Power connecting cables for isolator module,
assembled at one end
Power connecting cable for ET 200pro isolator modules,
open at one end, for HAN Q4/2, angled, insert turned at
isolator module end, 4 x 4 mm2
• Length 1.5 m 3RK1911-0DF13 1 1 unit 42D
• Length 5.0 m 3RK1911-0DF33 1 1 unit 42D
Power loop-through on the field device
& Power jumper plugs 3RK1922-2BQ00 1 1 unit 42D
+ Power loop-through plugs
Connector set for power loop-through for connection to
ET 200pro motor starters/ET 200pro isolator modules,

9
comprising a cable-end connector hood, angled
outgoing feeder, pin insert for HAN Q4/2, incl. gland
• 4 male contacts, 2.5 mm2 3RK1911-2BF50 1 1 unit 42D
• 4 male contacts, 4 mm2 3RK1911-2BF10 1 1 unit 42D
Motor cables
( Motor connection plugs
Connector set for motor cable for connection to
ET 200pro motor starters, comprising a cable-end
connector hood, angled outgoing feeder, pin insert
for HAN Q8/0, incl. gland
• 8 male contacts, 1.5 mm2 3RK1902-0CE00 1 1 unit 42D
• 6 male contacts, 2.5 mm2 3RK1902-0CC00 1 1 unit 42D
) Motor plugs
Connector set for motor cable for connection to motors,
comprising a cable-end connector hood, straight
outgoing feeder, female insert for HAN 10e, incl. star
jumper, incl. gland
• 7 female contacts, 1.5 mm2 3RK1911-2BM21 1 1 set 42D
• 7 female contacts, 2.5 mm2 3RK1911-2BM22 1 1 set 42D
* Motor plugs with EMC suppressor circuit
Connector set for motor cable for connection to motors,
comprising a cable-end connector hood, straight
outgoing feeder, female insert for HAN 10e with
EMC suppressor circuit, incl. star jumper, incl. gland
• 7 female contacts, 1.5 mm2 3RK1911-2BL21 1 1 set 42D
• 7 female contacts, 2.5 mm2 3RK1911-2BL22 1 1 set 42D

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 9/15
© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
Accessories for ET 200pro motor starters

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Motor cables (continued)


. Motor cables, assembled at one end
Open at one end, HAN Q8, angled length 5 m
• For motor without brake, for ET 200pro, 4 x 1.5 mm2 3RK1911-0EB31 1 1 unit 42D
• For motor with brake for ET 200pro, 6 x 1.5 mm2 3RK1911-0ED31 1 1 unit 42D
• For motor without brake, with thermistor, for ET 200pro, 3RK1911-0EF31 1 1 unit 42D
6 x 1.5 mm2
• For motor with brake and thermistor for ET 200pro, 3RK1911-0EG31 1 1 unit 42D
8 x 1.5 mm2
Power bus
0 Power T terminal connectors
For 400 V AC, for connection of feeders (e.g. motor
starters) by means of standard round cable at any point
of the power bus, by insulation displacement connection,
used with preassembled bus segments
• 2.5 mm2/4 mm2 3RK1911-2BF01 1 1 unit 42D
• 4 mm2/6 mm2 3RK1911-2BF02 1 1 unit 42D
1 Power double-T terminal connectors
For 400 V AC, for connection of feeders (e.g. motor
starters) by means of standard round cable at any point
of the power bus, by insulation displacement connection,
used with preassembled bus segments, connection of
two motor starters possible
• 4 mm2/6 mm2 3RK1911-2BG02 1 1 unit 42D
Sealing set (comprising 2 seals)
For power T/power double-T terminal connectors
• For power cables with Ø 10 ... 13 mm 3RK1911-5BA00 1 1 unit 42D
• For power cables with Ø 13 ... 16 mm 3RK1911-5BA10 1 1 unit 42D
• For power cables with Ø 16 ... 19 mm 3RK1911-5BA20 1 1 unit 42D
• For power cables with Ø 19 ... 22 mm 3RK1911-5BA30 1 1 unit 42D
• Blanking plugs 3RK1911-5BA50 1 1 unit 42D
Further accessories for power connections
Crimping tool 3RK1902-0CW00 1 1 unit 42D
For pins/sockets, 4 mm2 and 6 mm2
9

3RK1902-0CW00
Dismantling tools
• For male and female contacts for 9-pole HAN Q4/2 inserts 3RK1902-0AB00 1 1 unit 42D
• For male and female contacts for 9-pole HAN Q8 inserts 3RK1902-0AJ00 1 1 unit 42D
Sealing caps
For 9-pole power sockets
• 1 unit per pack 3RK1902-0CK00 1 1 unit 42D
• 10 units per pack 3RK1902-0CJ00 1 10 units 42D

3RK1902-0CK00

* You can order this quantity or a multiple thereof.


9/16 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
Accessories for ET 200pro motor starters

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Further accessories
Module racks, wide1)
• Length 500 mm 6ES7194-4GB00-0AA0 1 1 unit 250
• Length 1 000 mm 6ES7194-4GB60-0AA0 1 1 unit 250
• Length 2 000 mm 6ES7194-4GB20-0AA0 1 1 unit 250
Module racks, wide, compact1)
• Length 500 mm 6ES7194-4GD00-0AA0 1 1 unit 250
• Length 1 000 mm 6ES7194-4GD10-0AA0 1 1 unit 250
• Length 2 000 mm 6ES7194-4GD20-0AA0 1 1 unit 250
Backplane bus modules 110 mm2) 3RK1922-2BA00 1 1 unit 42D
Handheld devices 3RK1922-3BA00 1 1 unit 42D
For ET 200pro motor starters (or for
ET 200S High Feature and M200D motor starters)
for local operation.
Notes:
• The motor-starter-specific serial interface cables must
be ordered separately.
• The RS 232 interface cable 3RK1922-2BP00 is used for
the MS ET 200pro.
RS 232 interface cable 3RK1922-2BP00 1 1 unit 42D
3RK1922-3BA00
Serial data connection between ET 200pro (or M200D)
motor starters and the RS 232 interface of a PC/PG/laptop
(with the Motor Starter ES software) or the handheld device
3RK1922-3BA00.
USB interface cable, 2.5 m 6SL3555-0PA00-2AA0 1 1 unit 368
Serial data connection between ET 200pro (or M200D)
motor starters and the USB interface of a PC/PG/laptop
(with the Motor Starter ES software).
M12 sealing caps 3RK1901-1KA00 100 10 units 42C
For sealing unused M12 input or output sockets
(one set contains ten sealing caps)

3RK1901-1KA00
Motor suppression module
RC element for installation in motor terminal box

9
• Angled design 3RK1911-6EA00 1 1 unit 42D

3RK1911-6EA00
• Round design 3RK1911-6EB00 1 1 unit 42D

3RK1911-6EB00
1)
The wide module rack can accommodate all ET 200pro motor starters and
any optional modules (isolator module, 400 V disconnecting module).
2)
The backplane bus module is a prerequisite for operation of the
ET 200pro motor starter and the optional module.
For more connection technology products, see
https://support.industry.siemens.com/cs/ww/en/view/65355810.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 9/17
© Siemens 2023

Motor starters for use in the field, high degree of protection


ET 200pro motor starters
Software
Motor Starter ES

■ Overview
More information
Industry Mall, see www.siemens.com/product?3ZS1
Technical specifications and system requirements, see
https://support.industry.siemens.com/cs/ww/en/ps/16713/td

Motor Starter ES is used for start-up, parameterization,


diagnostics, documentation and the preventative maintenance
of the motor starters in the SIMATIC ET 200S, ET 200pro,
ECOFAST and M200D product families.
The software program is available in three versions which differ
in their user-friendliness, scope of functions and price.
For detailed information on the Motor Starter ES software, see
page 14/10.

Motor Starter ES for parameterization, monitoring, diagnostics and


testing of motor starters
9

9/18 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
General data

■ Overview
More information
Homepage, see www.siemens.com/sirius-motor-starter-m200d
Industry Mall, see www.siemens.com/product?M200D
Decision support for motor start – Starting and operating three-phase
asynchronous motors efficiently, see www.siemens.com/motorstart-guide
TIA Selection Tool Cloud (TST Cloud), see
www.siemens.com/tstcloud/?node=MS_M200D

Basic functionality
The versions of the M200D motor starter are equipped with the
following properties and functions:
• Available as direct-on-line and reversing starters in a rugged
design
• Electromechanical or electronic switching version
• Low variance – only two device versions up to 5.5kW thanks
to wide range setting
• All versions have the same enclosure size.
SIRIUS M200D AS-i Basic motor starter with manual local operation
• Degree of protection IP65
The intelligent and highly flexible SIRIUS M200D motor starters
for distributed installation start, monitor and protect motors and • Quick and fail-safe wiring of system and motor cables using
loads up to 5.5 kW. ISO 23570 plug-in connector technology (Q4/2 and Q8/0)
• Robust and widely used M12 connection method for digital
The M200D motor starters are available in four versions: inputs and outputs
M200D M200D M200D M200D • Integrated feeder connector monitoring
AS-i Basic AS-i Standard PROFIBUS PROFINET • Full motor protection through overload protection and
Motor control with a temperature sensor (PTC, TC)
AS-i communication PROFIBUS PROFINET • Short-circuit and overload protection integrated
Mechanical or electronic switching • Integrated repair switch lockable with three locks
✓ ✓ ✓ ✓ (multi-level service)
Electronic switching with soft starter functionality • Uniform wiring to the SINAMICS G115D and
-- ✓ ✓ ✓ SINAMICS G120D frequency converters and to the
ET 200pro distributed I/O system

9
✓ Function available • Extensive diagnostics concept using LEDs
-- Function not available
• Optionally available integrated manual local control with key-
Voltage data operated switch (ordering option)
The specifications for 3-phase systems according to • Optionally available brake actuation with voltages from
IEC 60947-4-1 apply for the following line system configurations: 180 V DC (no rectifier needed in motor) or 230/400 V AC
.
(order versions)
Voltage Ue Line system configurations
Three-phase Three-phase
four-wire systems three-wire systems
IC01_00703

IC01_00709

V V V
230 -- 230
400 230/400 400
440 260/440 440
500 -- 500
-- Not specified

Siemens IC 10 · 2023 9/19


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
General data
Article number scheme

Product versions Article number


Motor starters 3RK13 @ 5 – 6 @ S @ 1 – @ A @ @
Type AS-i Basic 1 A
AS-i Standard 2 A
PROFIBUS/PROFINET 9 D
Setting range for rated 0.15 ... 2 A K
operational current IA 1.5 ... 9 A N
1.5 ... 12 A L
Starter version Electromechanical starters 4 With integrated contactor
Electronic starters 7 With thyristors
Product function Direct-on-line starters 0
Reversing starters 1
Direct-on-line starters 2 With manual local operation
Reversing starters 3 With manual local operation
Brake actuation None 0
230/400 V AC 3
180 V DC 5
Example 3RK13 1 5 – 6 K S 4 1 – 3 A A 0

Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

■ Benefits
M200D motor starters provide the following advantages for • Comprehensive offering of accessories, including
customers: ready-assembled cables
• High plant availability through plug-in capability of the main • The M200D motor starters can be installed with a few manual
circuit, communication and I/Os – relevant for installing and steps. The integrated plug-in technology enables far lower
replacing devices wiring outlay:
• Cabinet-free construction and near-motor installation thanks Preassembled cables can be plugged directly onto the motor
9

to the high degree of protection IP65 starter module.


• The motor starters record the actual current flow for the • Easy and user-friendly installation because all versions have
parameterizable electronic motor overload protection. the same enclosure dimensions.
Reliable messages concerning the overshooting or • Fast and user-friendly commissioning using optional manual
undershooting of setpoint values ensure comprehensive local operation
motor protection. All motor protection functions can be • Increase of process speed through integrated functions such
defined by simple parameterization as "Quick Stop" and "Disable Quick Stop", e.g. at points and
• Low stock levels and low ordering effort thanks to a wide crossings
setting range for the electronic motor protection of 1:10 • Optional manual local control with momentary-contact and
(only two device versions up to 5.5 kW) latching operation for easier startup and easier servicing
• The integrated wide range for the current enables a single
device to cover numerous standard motors of different sizes.

■ Application
The high degree of protection IP65 makes the M200D motor Use of SIRIUS M200D motor starters in conjunction with
starters suitable in particular for use on extensive conveying IE3 and IE4 motors
systems such as are found in mail sorting centers, airports,
automotive factories and the packing industry. Note:

For simple drive tasks, particularly in conveyor applications, For the use of SIRIUS M200D motor starters in conjunction
the new SINAMICS G115D frequency converter series with with highly efficient IE3 and IE4 motors, please observe the
a performance range from 0.37 kW to 7.5 kW and degree of information on dimensioning and configuring, see Application
protection IP65 is the ideal partner for the M200D motor starters. Manual.

SINAMICS G115D converters allow for continuous speed control For more information, see page 1/8.
of three-phase asynchronous motors and comply with the
requirements of conveyor technology applications with
frequency control (for more information, see Catalog D 31.2).

9/20 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for AS-Interface
General data

■ Overview
For motor control using AS-Interface there are the following Mounting and installation
M200D motor starter versions: SIRIUS M200D AS-i Basic and
SIRIUS M200D AS-i Standard (basic functionality, see page 9/19 The M200D motor starters can be installed with a few manual
"SIRIUS M200D motor starters" ➞ "General data" ➞ "Overview"). steps. The integrated plug-in technology enables far lower
wiring outlay. Connecting cables can be plugged directly onto
SIRIUS M200D AS-i Basic the motor starter module. Swapping of the connecting wires and
malfunctions within the plant are prevented by preassembled
Functionality cables. The AS-i bus is connected cost-effectively using an
• Easy and fast on-site startup through parameterization of local M12 connection on the device. All versions have identical
setting knobs (DIP switches) and rotary coding switches for enclosure dimensions for easier system design and conversion.
adjusting the rated operational current. The rotary coding
switch has an OFF position for deactivating the overload Parameterization and configuration
protection with the help of the thermal motor model when The particularly robust M200D AS-i Standard motor starter is
using a temperature sensor. characterized by numerous functions which can be flexibly
Communications parameterized. It enables highly flexible parameterization
through the AS-i bus using data records from the user program
• AS-i communication with A/B addressing according to as well as user-friendly local parameterization using the
Spec V2.1 Motor Starter ES startup software through the local point-to-point
• The AS-i bus is connected cost-effectively using an interface.
M12 connection on the device. Of the four digital inputs, Functions can be flexibly assigned to the digital inputs and
two are contained in the process image and can therefore outputs, adapting them to all possible conveyor applications.
be used in the PLC program. The other two inputs are locally All motor protection functions, limit values and reactions can be
effective and permanently assigned with functions. defined by parameterization. The AS-i Standard is unique. In its
• The LEDs can provide comprehensive diagnostics of the 6E/4A process image the motor starter sends all four digital
device on the spot. In addition to diagnostics using the inputs and the digital output via the process image to the PLC in
PAE process image, the device can create up to 15 different cyclic mode. System configuration and system documentation
diagnostic messages per slave. The message with the highest are facilitated not least by a number of CAX data.
priority can be read out through the AS-i communication.
This is yet another new development which distinguishes Operation
the M200D AS-i Basic motor starter from the rest of the market The new generation of motor starters is characterized by its
and adds innovative technology, maximum availability and advanced functionality, maximum flexibility and extremely high
transparency to the system. degree of automation.
SIRIUS M200D AS-i Standard All digital inputs and outputs exist in the cyclic process image.
The intelligent and highly flexible M200D AS-i Standard motor All limit values for monitoring functions and their reactions are
starter in A/B technology starts and protects motors and loads parameterizable and therefore adaptable to the application.
The motor starters record the actual current flow. Evaluating the

9
up to 5.5 kW. It is available in direct-on-line or reversing starter
versions, in a mechanical version and also a solid-state version current of the parameterizable electronic overload protection
(the latter with soft start function). increases the availability of the drives, as do reliable messages
concerning the overshooting or undershooting of setpoint values.
The M200D AS-i Standard motor starter is the most functional
member of the SIRIUS motor starter family in the high degree of Diagnostics and preventive maintenance
protection IP65 for AS-i communication. Consistency with other The M200D sets new standards for diagnostics. In addition to
products of the SIRIUS M200D motor starter range and with the diagnostics using the PAE process image and diagnostics by
frequency converter and ET 200pro I/O system is assured. "parameter echo" (up to 15 different diagnostic messages per
Functionality slave can be read out via AS-i communication), the possibility of
reading out diagnostic data records is unique on the market.
• AS-i communication with A/B addressing according
to Spec 3.0 The AS-i Standard is recommended in particular for expansive
and highly automated system components because the
• Solid-state version also with soft start function possibility of monitoring devices and systems with data records
• AS-i slave profile 7AE/7A5 with process image 6E/4A (statistical data, measured values and device diagnostics)
• Full TIA integration: All digital inputs and outputs exist in the provides an in-depth view of the plant from the control room,
cyclic process image and are visible through AS-i, providing guaranteeing the monitoring process and increasing plant
maximum flexibility and best adaptability to the application. availability.
• Additionally expanded diagnostics using data record through Preventive maintenance can be carried out with the integrated
AS-i bus maintenance timer and plant downtimes prevented as a result in
• Complete plant monitoring using statistics data record and advance.
current value monitoring by means of data records Local control of a drive is possible using the ordering option
• Parameterization through AS-i bus with the help of data with integrated manual local operation. This is yet another new
records or an expanded process image from the user program development which distinguishes the M200D AS-i Standard
• Control of the motor starter using a command data record from motor starter from the rest of the market and adds innovative
the user program technology, maximum availability and transparency to the plant.
• Flexible assignment of the digital inputs and outputs with all
available assignable input actions
• Parameterization using Motor Starter ES at the local interface
(ordering option for startup software)
• Diagnostics with the help of Motor Starter ES (ordering option
for startup software)

Siemens IC 10 · 2023 9/21


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for AS-Interface
General data

SIRIUS M200D SIRIUS M200D


AS-i Basic AS-i Standard
Device functions (firmware features)
Slave on the bus
Fieldbus ✓ AS-i
Slave type ✓ A/B according to Spec 2.1 ✓ A/B according to Spec 3.0
Profile ✓ 7.A.E ✓ 7.A.E & 7.A.5
Number of assigned AS-i addresses on the bus ✓ 1 ✓ 2
Number of stations per AS-i master ✓ Max. 62 devices ✓ Max. 31 devices
AS-i master profile ✓ M3 and higher ✓ M4 and higher
Parameter assignment
DIP switches ✓ --
Potentiometer for rated operational current ✓ --
Motor Starter ES -- ✓
Data records through AS-i -- ✓
Diagnostics
Diagnostics through parameter channel ✓
Acyclic through data records -- ✓
Expanded process image PAE 4 bytes -- ✓
Process image
Process image ✓ 4E/3A ✓ 6E/4A
Data channels
Local optical interface (manual local) ✓
AS-i bus ✓
9

Motor Starter ES through local interface -- ✓


Motor Starter ES through bus --
Data records1) (acyclic)
Parameter assignment -- ✓
Diagnostics -- ✓
Measured values -- ✓
Statistics -- ✓
Commands -- ✓
Inputs
Number ✓ 4
• Of these in the process image ✓ 2 through AS-i ✓ 4 through AS-i
Input action ✓ For permanently assigned functions, see manual ✓ Parameterizable: flexible
Quick stop ✓ Permanent function: latching, edge-triggered ✓ Parameterizable function: latching
(edge-triggered), non-latching (level-triggered)
Outputs
Number ✓ 1
Output action ✓ Permanent function: assigned with group fault ✓ Parameterizable: For function, see manual
Brake output
180 V DC/230/400 V AC/without ✓
Motor protection
Overload protection ✓ Electronic, wide range 1:10
Short-circuit protection ✓
Full motor protection ✓
Temperature sensor ✓ Parameterizable using DIP switches: ✓ Parameterizable via Motor Starter ES, data
PTC or Thermoclick or deactivated record: PTC or Thermoclick or deactivated

✓ Function available
-- Function not available
1) The data records are a reduced selection compared with
PROFIBUS/PROFINET.

9/22 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for AS-Interface
General data

SIRIUS M200D SIRIUS M200D


AS-i Basic AS-i Standard
Device functions (firmware features) (continued)
Device function
Repair switch ✓
Current limit monitoring bottom -- ✓ Parameterizable
Current limit monitoring top -- ✓ Parameterizable
Residual current detection ✓ Permanent function: disconnection, less than ✓ Parameterizable
18.75% of the rated operational current Ie
Blocking current ✓ Permanent function: starting up of the motor: ✓ Parameterizable
tripping limit up to 800% of the rated operational
current Ie for 10 s
Active operation: threshold for tripping
"blocking current" up to 400% of the rated
operational current Ie
Asymmetry ✓ Permanent function: up to 30% of the rated ✓ Parameterizable
operational current Ie (only mechanical MS)
Load type ✓ Permanent function: 3-phase ✓ Parameterizable: 1-phase and 3-phase
Shutdown class ✓ Parameterizable using DIP switches: Parameterizable via Motor Starter ES,
CLASS 10/deactivated data record: CLASS 5, 10, 15, 20
Protection against voltage failure ✓ ✓ Parameterizable: activated/deactivated
Soft starter control function
Soft start function -- ✓ Only solid-state version
Bypass function -- ✓ Only solid-state version

✓ Function available

9
-- Function not available

■ Application
The M200D AS-i Standard is particularly suitable for highly Use of M200D motor starters in conjunction with
automated applications in conveyor systems requiring devices IE3 and IE4 motors
and systems to be monitored to prevent or limit plant downtime.
The option of parameterizing the functions of the motor starter or Note:
its interfaces also creates the prerequisite for fine-adjustment to For the use of SIRIUS M200D motor starters in conjunction
the function of the motor starter in the application and hence with highly efficient IE3 and IE4 motors, please observe the
provides for extreme flexibility. information on dimensioning and configuring, see Application
Manual.
For more information, see page 1/8.

■ Technical specifications
More information
Manuals for SIRIUS M200D: Notes on security:
• AS-i Basic, see In order to protect plants, systems, machines and networks against cyber
https://support.industry.siemens.com/cs/ww/en/view/35016496 threats, it is necessary to implement – and continuously maintain – a holistic,
• AS-i Standard, see state-of-the-art industrial security concept. Siemens products and solutions
https://support.industry.siemens.com/cs/ww/en/view/38722160 represent only one component of such a concept.
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16324/faq For more information on the subject of Industrial Security, see
www.siemens.com/industrialsecurity.

Siemens IC 10 · 2023 9/23


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for AS-Interface
General data

Type M200D motor starters


AS-i Basic AS-i Basic AS-i Standard AS-i Standard
electromechanical electronic electromechanical electronic
switching switching switching switching
Technology designation1) DSte/RSte sDSte/sRSte DSte/RSte sDSSte/sRSSte
Mechanics and environment
Mounting dimensions (W x H x D) mm 294 x 215 x 159
Permissible ambient temperature
• During operation °C -25 ... +55
• During storage °C -40 ... +70
Weight g 2 880/3 130 3 220/3 420 2 880/3 130 3 220/3 420
Permissible mounting position Vertical, horizontal, lying
Vibration resistance according to IEC 60068-2-6 g 2
Shock resistance
• According to IEC 60068-2-27 g/ms 12/11 half-sine
• Without influencing the contact position g/ms 9.8/5 or 5.9/10
Degree of protection according to IEC 529 IP65
Installation altitude
• Up to 1 000 m No derating
• Up to 2 000 m 1% per 100 m
Cooling Convection
Protection class IEC 536 (DIN VDE 0106-1) 1
Electrical specifications
Control circuit
Operational voltage UAs-i V DC 26.5 ... 31.6
Supply voltage Uaux V DC 20.4 ... 28.8
Power consumption from AS-i (incl. 200 mA sensor supply) mA < 300
Current consumption from Uaux (without digital output)
• Max. mA 155 15 (direct-on-line)/ 155 15 (direct-on-line)/
175 (reversing) 175 (reversing)
• Typ. mA 75 10 (direct-on-line)/ 75 10 (direct-on-line)/
75 (reversing) 75 (reversing)
Main circuit
Maximum power of three-phase motors at 400 V AC kW 5.5 4 5.5 5.5
Rated operational voltage Ue
9

• Approval according to IEC 60947-1 V AC 400 (50/60 Hz)


• Approval according to UL and CSA V AC 600 (50/60 Hz) 480 (50/60 Hz) 600 (50/60 Hz) 480 (50/60 Hz)
• Rated operational current range A 0.15 ... 2/1.5 ... 12 -- 0.15 ... 2/1.5 ... 12 --
• Rated operational current range for soft starting A -- 0.15 ... 2/1.5 ... 12
• Rated operational current range for direct-on-line A -- 0.15 ... 2/1.5 ... 9 -- 0.15 ... 2/1.5 ... 9
starting
Rated operational current Ie for starters at 400 V AC
• 400 V at AC-1, AC-3 and AC-3e A 12 -- 12 --
• 500 V at AC-1, AC-3 and AC-3e A 9 -- 9 --
• 400 V at AC-4 A 4 -- 4 --
• 400 V at AC-53a A -- 9 -- 12 for soft starting
9 for direct-on-line
starting
Mechanical endurance of contactor Oper- 30 million -- 30 million --
ating
cycles
Trip class CLASS 10 CLASS 5, 10, 15, 20
Type of coordination according to IEC 60947-4-1 1 (2 for device 1 1 (2 for device 1
version 2A) version 2A)
Permissible switching frequency see manual see manual
Rated ultimate short-circuit breaking capacity Iq
• At 400 V AC kA 50
• At 500 V AC kA 502) 202) 50 202)
Short-circuit protection
• At Iemax = 2 A Integrated, 2 x 3 Ie = 26 A
• At Iemax = 9/12 A Integrated, 2 x 3 Ie = 208 A
Brake actuation (option)
Operational voltage V 230/400 AC or 180 DC
Uninterrupted current A < 0.5 at 230/400 V AC
< 0.8 at 180 V DC
Short-circuit protection Yes, 1 A melting fuse
1) DS .... Direct-on-line starters
RS .... Reversing starters
DSS .. Direct-on-line soft starters
RSS .. Reversing soft starters
te ...... Full motor protection (thermal + electronic)
s ....... Electronic switching with semiconductor.
2)
Only systems with grounded neutral point permitted.

9/24 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for AS-Interface
AC-3e E3 ready IE4 ready IE3/IE4 ready M200D Basic motor starters

■ Selection and ordering data

M200D AS-i Basic without manual local operation M200D AS-i Basic with manual local operation

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Electromechanical starters (with integrated contactor)


3RK1315-6@S41-@AA@ 1 1 unit 42D
Rated operational current setting range/A Add. price
• 0.15 ... 2 K None
• 1.5 ... 12 L ✓
Direct-on-line starters/reversing starters
• Direct-on-line starters 0 None
• Reversing starters 1 ✓
• Direct-on-line starters with manual local operation 2 ✓
• Reversing starters with manual local operation 3 ✓
Brake actuation
• Without brake actuation 0 None
• Brake actuation (230/400 V AC) 3 ✓
• Brake actuation (180 V DC) 5 ✓
Electronic starters (with thyristors)
3RK1315-6@S71-@AA@ 1 1 unit 42D
Rated operational current setting range/A Add. price

9
• 0.15 ... 2 K None
• 1.5 ... 9 N ✓
Direct-on-line starters/reversing starters
• Direct-on-line starters 0 None
• Reversing starters 1 ✓
• Direct-on-line starters with manual local operation 2 ✓
• Reversing starters with manual local operation 3 ✓
Brake actuation
• Without brake actuation 0 None
• Brake actuation (230/400 V AC) 3 ✓
• Brake actuation (180 V DC) 5 ✓
✓ = Additional price

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 9/25
© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for AS-Interface
M200D Standard motor starters IE3 ready IE4 ready IE3/IE4 ready
AC-3e

■ Selection and ordering data

M200D AS-i Standard without manual local operation M200D AS-i Standard with manual local operation

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Electromechanical starters (with integrated contactor)


3RK1325-6@S41-@AA@ 1 1 unit 42D
Rated operational current setting range/A Add. price
• 0.15 ... 2 K None
• 1.5 ... 12 L ✓
Direct-on-line starters/reversing starters
• Direct-on-line starters 0 None
• Reversing starters 1 ✓
• Direct-on-line starters with manual local operation 2 ✓
• Reversing starters with manual local operation 3 ✓
Brake actuation
• Without brake actuation 0 None
• Brake actuation (230/400 V AC) 3 ✓
• Brake actuation (180 V DC) 5 ✓
Electronic starters (with thyristors)
3RK1325-6@S71-@AA@ 1 1 unit 42D
Rated operational current setting range/A Add. price
9

• 0.15 ... 2 K None


• 1.5 ... 12 L ✓
Direct-on-line starters/reversing starters
• Direct-on-line starters 0 None
• Reversing starters 1 ✓
• Direct-on-line starters with manual local operation 2 ✓
• Reversing starters with manual local operation 3 ✓
Brake actuation
• Without brake actuation 0 None
• Brake actuation (230/400 V AC) 3 ✓
• Brake actuation (180 V DC) 5 ✓
✓ = Additional price

* You can order this quantity or a multiple thereof.


9/26 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for PROFIBUS/PROFINET
General data

■ Overview
The intelligent, highly flexible M200D PROFIBUS/PROFINET
motor starters are the most functional motor starters of the
SIRIUS motor starter family in the high degree of protection IP65
for PROFIBUS/PROFINET communication.
They start and protect motors and loads up to 5.5 kW.
Direct-on-line and reversing starter versions are available
in a mechanical version and also a solid-state version
(the latter with soft start function).
The particularly robust M200D PROFIBUS/PROFINET motor
starters are characterized by numerous functions which can be
flexibly parameterized. Their modular design comprises a motor
starter module and a communications module.
The M200D PROFINET motor starters enable TIA-integrated
parameterization through PROFINET from STEP 7 – in familiar,
user-friendly manner with the look and feel of PROFIBUS.
Functionality
• For basic functionality, see page 9/19 "SIRIUS M200D motor
starters" ➞ "General data" ➞ "Overview" M200D motor starter module for PROFIBUS/PROFINET
• Solid-state version also with soft start function (without communications module)

• Robust and widely used M12 connection method for the


digital inputs and outputs and the PROFIBUS/PROFINET
bus connection
• All four digital inputs and two digital outputs exist in the cyclic
process image. This provides complete transparency of the
process on the control level
• Full TIA integration: All digital inputs and outputs exist in
the cyclic process image and are visible via the bus, providing
maximum flexibility and excellent adaptability to
the application
• Flexible assignment of the digital inputs and outputs with
all available assignable input actions
• Extensive diagnostics concept using LEDs and through

9
the bus with the TIA-compatible mechanisms
• Expanded diagnostics using data records
• Complete plant monitoring using statistics data record and
current value monitoring by means of data records
• Parameterization through PROFIBUS/PROFINET bus with M200D communications module for PROFIBUS
the help of data records from the user program
• Control of the motor starter using a command data record from
the user program
• Removable modular control unit – quicker device replacement
and therefore lower costs when device outages occur – since
existing wiring is on the control unit and only one device needs
to be replaced
• Parameterization in STEP 7 HW Config via Motor Starter ES
(ordering option for startup software)
• Startup and diagnostics with the help of Motor Starter ES
(ordering option for startup software)
• Trace function through Motor Starter ES for optimized startup
and tracking of process and device values
Only with PROFINET:
• Just one bus system from the MES level to the devices –
no routers
• More stations on the bus and possible configuration of flexible M200D communications module for PROFINET
bus structures
• Automatic re-parameterization in case of device replacement
thanks to proximity detection
• Wireless integration of plant segments in difficult environ-
ments using WLAN
• Easier expansion of the system thanks to a higher number of
stations on the bus and elimination of terminating resistors

Siemens IC 10 · 2023 9/27


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for PROFIBUS/PROFINET
General data
Mounting and installation The motor starter is TIA-diagnostics compatible, which means
that when a fault is identified, a diagnostics alarm is distributed,
The M200D PROFIBUS/PROFINET motor starter is comprised which invokes the diagnostics-OB with a SIMATIC control.
of the communications module and the motor starter module. The fault can be evaluated as usual in the user program.
Only the motor starter module has to be replaced therefore
when replacing devices. This saves time and money. The M200D motor starter offers a large variety of diagnostics
The communications module remains as an active station on data through data records. Its functionality is without equal on
the bus and all other system components continue running. the market. There are extensive options for reading out data from
This prevents downtimes. the motor starter for monitoring devices, systems or processes.
The integrated plug-in technology enables far lower wiring The motor starter is equipped internally with three logbooks for
outlay: Connecting cables can be plugged directly onto the device faults, motor starter trips and events that are issued with
motor starter module. The PROFINET bus is connected a time stamp. These logbooks can be read out of the motor
cost-effectively using an M12 connection on the device. starter at any time in the form of data records and provide the
All versions have identical enclosure dimensions for easier plant operator with plenty of information about the state of his
system design and conversion. plant and process which he can use to carry out improvements.
Parameterization and configuration With the slave pointer and statistical data functions it is possible
to read out, for example, the maximum internal current values or
All motor protection functions, limit values and reactions can be the number of motor starter connection operations for plant
defined by parameterization. monitoring purposes. This allows deviations in the process to be
The user has several user-friendly options for the parameteri- monitored, but also optimum initial commissioning to take place.
zation. In addition to parameterization directly from STEP 7, The user can draw conclusions about the actual load conditions
which also permits automatic re-parameterization in case of of the devices in his process and on this basis can optimize his
device replacement, it is possible to use the user-friendly Motor plant maintenance intervals.
Starter ES startup software. By connecting a programming The device diagnostics data record contains details of all
device directly to PROFIBUS/PROFINET and the Motor Starter ES the states of the motor starter, the device configuration and
startup software, the devices can also be conveniently the communication status as a basis for central monitoring of
programmed from a central point through the bus. Also, devices and systems.
parameters can be changed during operation from the user
program using the data record mechanism so that the function With installation and maintenance functions (I&M), information
of the motor starter is adapted to the process when required. on modules employed and data specified by the user during
With the help of a PC and the Motor Starter ES software it is also configuration, such as location designations, are stored in the
possible to perform the parameterization through the local point- motor starter. I&M functions are used for troubleshooting faults
to-point interface on-site. and localizing changes in hardware in a plant or checking the
system configuration. Reordering a device is particularly easy
Functions can be flexibly assigned to the digital inputs and as the result.
outputs, adapting them to all possible conveyor applications.
All digital inputs and outputs exist in the cyclic process image. The integrated maintenance timer can be used to implement
All limit values for monitoring functions and their reactions are preventive maintenance and avoid plant downtimes through
9

parameterizable and therefore adaptable to the application. look-ahead servicing.


Consistency with other products of the SIRIUS M200D
motor starter range and with the frequency converter and Another new addition is the TRACE integrated into the
ET 200pro I/O system is assured. Motor Starter ES software. It can be used to record measured
values as a function of time following a trigger event. This enables
Only with M200D PROFINET motor starters process flows to be recorded and their timing optimized.
Thanks to the integrated proximity detection, the device name Local control of a drive is possible using the ordering
does not need to be issued manually when a device is replaced. option with integrated manual operation. This is yet
The name is issued automatically by the neighboring devices another new development which distinguishes the
which note the "names" of the devices in their proximity. M200D PROFIBUS/PROFINET motor starter from the rest
No additional startup measures are required therefore when of the market and adds innovative technology, maximum
replacing a device. availability and transparency to the system.
The new motor starter generation is characterized by high M200D PROFINET motor starters with PROFIenergy
functionality, maximum flexibility and the highest level of
automation. PROFINET is especially recommended for Increasing energy prices, far-reaching ecological problems
large-scale and highly automated system components, worldwide and the threat of climate change make it necessary
since the possibility of monitoring the devices or systems with for you to be more conscious about your use of energy.
data records (statistical data, measured values and device Active and effective energy management is possible with
diagnostics) ensures a broader insight into the plant by the PROFIenergy.
control room, and hence increases the availability of the plant
sustainably. PROFIenergy is a manufacturer-independent profile on
PROFINET, which can be used by all manufacturers, has been
Operation standardized by PNO1) and supports switching off electrical
The motor starters record the actual current flow. Evaluating the devices during dead times and measuring the energy flow.
1)
current of the parameterizable electronic overload protection In the PNO (PROFIBUS Nutzerorganisation e. V. – PROFIBUS User
increases the availability of the drives, as do reliable signals Organization), manufacturers and users have come together to agree on
the standardized communication technologies PROFIBUS and PROFINET.
concerning the overshooting or undershooting of setpoint
values.
Diagnostics and preventive maintenance
Diagnostics is provided through numerous mechanisms –
and can be used as the customer prefers.

9/28 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for PROFIBUS/PROFINET
General data
Switching off during dead times PROFIenergy enables consumption data to be read off from the
devices in a unified form. This is recorded during operation and
PROFIenergy supports the targeted switching-off of loads can be displayed on a control panel, for example, or on overlying
during dead time. energy management software packages. This ensures that the
These can be planned short breaks of a few minutes (such as measured variables are in a uniform manufacturer-independent
lunch breaks), longer dead times (such as nights) or unplanned form and structure that is available to the user for further
dead times. Energy is always saved when no power is required. processing. These PROFIenergy functions thus provide the
basis for active load and energy management during operation.
Measuring and visualizing the energy flow as a basis of
energy management PROFIenergy in the M200D PROFINET motor starter
The objective of energy management is to optimize the use of The M200D PROFINET motor starter supports the "switching
energy in a company – from the purchasing of energy through to during dead times" and "current measurement values" of the
the consumption of energy – economically and ecologically. motor current using PROFIenergy. These are called commands,
because they trigger a reaction in the M200D motor starter.
Analyses of energy consumption over time can be used to
control energy flows, avoid energy peaks, improve ratings and
thus save costs.

SIRIUS M200D SIRIUS M200D


PROFIBUS PROFINET
Device functions (firmware features)
Slave on the bus
Fieldbus ✓ PROFIBUS to M12 ✓ PROFINET to M12
Adjustable number of stations ✓ 1 ... 125 ✓ 1 ... 128 with CPU 315, CPU 317
1 ... 1 256 with CPU 319
Parameter assignment
DIP switches ✓ For address setting and terminating resistor --

9
Motor Starter ES ✓ Through bus, optical interface
PROFIBUS/PROFINET data records ✓
From STEP 7/HW Config ✓
Diagnostics
Acyclic through data records ✓
Diagnostics alarm ✓
Process image
Process image ✓ 2 bytes PAE/2 bytes PAA
Data channels
Local optical interface (manual local) ✓
Using Motor Starter ES through local interface ✓
Using Motor Starter ES through bus ✓
Data records (acyclic)
Parameter assignment ✓ Using DS 131 (DS = data record)
Diagnostics ✓ Device-specific DS 92
Measured values ✓ Measured values DS 94
Statistics ✓ Statistical data DS 95
Commands ✓ Using DS 93
Slave pointer ✓ Slave pointer DS 96
Logbook ✓ Using Motor Starter ES and data records: device faults DS 72, tripping operation DS 73, events DS 75
Device identification ✓ Using DS 100
I&M data ✓ Using DS 231 ... 234 ✓ Using data records 0xAFF0 ... 0xAFF3
Inputs
Number ✓ 4
• Of these in the process image ✓ 4
Input action ✓ Parameterizable: For flexibly assignable action, see manual
Quick stop ✓ Parameterizable: latching, non-latching
✓ Function available
-- Function not available

Siemens IC 10 · 2023 9/29


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for PROFIBUS/PROFINET
General data

SIRIUS M200D SIRIUS M200D


PROFIBUS PROFINET
Device functions (firmware features) (continued)
Outputs
Number ✓ 2
• Of these in the process image ✓ 2
Output action ✓ Parameterizable: For flexibly assignable action, see manual

Brake output
180 V DC/230/400 V AC/without ✓
Motor protection
Overload protection ✓ Electronic, wide range 1:10
Short-circuit protection ✓
Full motor protection ✓
Temperature sensor ✓ Parameterizable via Motor Starter ES, data record: PTC or Thermoclick or deactivated
Device function
Repair switch ✓
Current limit monitoring bottom ✓ Parameterizable
Current limit monitoring top ✓ Parameterizable
Residual current detection ✓ Parameterizable: tripping, warning
Blocking current ✓ Parameterizable
Asymmetry ✓ Parameterizable
Load type ✓ Parameterizable: 1-phase and 3-phase
Shutdown class ✓ Parameterizable via Motor Starter ES, data record: CLASS 5, 10, 15, 20
9

Protection against voltage failure ✓ Parameterizable: activated/deactivated


Support for PROFIenergy profile
Switching during dead times -- 3
Measured motor current values -- 3
Soft starter control function
Soft start function ✓
Bypass function ✓ Only solid-state version

✓ Function available
-- Function not available

■ Benefits
M200D PROFINET motor starters with PROFIenergy
Both standards and laws are making environmental protection It is thus an objective within the industry to save energy and
and energy management increasingly important, as is the desire actively reduce CO2 emissions. By the careful use of valuable
to cut energy costs in production facilities and thus ensure resources, the manufacturer-independent PROFIenergy profile
a sustainable competitive advantage. on PROFINET can make an active contribution to environmental
protection.

■ Application
M200D PROFIBUS/PROFINET motor starters are particularly Adaptability of the motor starter functions and maximum
suitable for fully TIA-integrated, highly automated conveyor flexibility of the device enable a broad range of application
applications that meet all needs with regard to the monitoring without any limits. The PROFINET-specific expansions are
of devices and systems and preventive maintenance. the best assurance of a future-proof investment.

9/30 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for PROFIBUS/PROFINET
General data

■ Technical specifications
More information
Equipment Manual for M200D PROFIBUS/PROFINET, see Notes on security:
https://support.industry.siemens.com/cs/ww/en/view/38823402 In order to protect plants, systems, machines and networks against cyber
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16325/faq threats, it is necessary to implement – and continuously maintain – a holistic,
state-of-the-art industrial security concept. Siemens products and solutions
represent only one component of such a concept.
For more information on the subject of Industrial Security, see
www.siemens.com/industrialsecurity.

Type M200D PROFIBUS/PROFINET motor starter modules


Electromechanical switching Electronic switching
Technology designation1) DSte/RSte sDSSte/sRSSte
Mechanics and environment
Mounting dimensions (W x H x D)
• Without communications module mm 294 x 215 x 159
• With communications module mm 295 x 215 x 163
Permissible ambient temperature
• During operation °C -25 ... +55
• During storage °C -40 ... +70
Weight g 2 820/3 080 3 160/3 360
Permissible mounting position Vertical, horizontal, lying
Vibration resistance according to IEC 60068-2-6 g 2
Shock resistance
• According to IEC 60068-2-27 g/ms 12/11 half-sine
• Without influencing the contact position g/ms 9.8/5 or 5.9/10
Degree of protection according to IEC 529 IP65
Installation altitude
• Up to 1 000 m No derating
• Up to 2 000 m 1% per 100 m
Cooling Convection
Protection class IEC 536 (DIN VDE 0106-1) 1
Electrical specifications
Main circuit
Maximum power of three-phase motors at 400 V AC kW 5.5

9
Rated operational voltage Ue
• Approval according to EN 60947-1 V AC 400 (50/60 Hz)
• Approval according to UL and CSA V AC 600 (50/60 Hz) 480 (50/60 Hz)
• Rated operational current range A 0.15 ... 2/1.5 ... 12 --
• Rated operational current range for soft starting A -- 0.15 ... 2/1.5 ... 12
• Rated operational current range for direct-on-line starting A -- 0.15 ... 2/1.5 ... 9
Rated operational current Ie for starters at 400 V AC
• 400 V at AC-1, AC-3 and AC-3e A 12 --
• 500 V at AC-1, AC-3 and AC-3e A 9 --
• 400 V at AC-4 A 4 --
• 400 V at AC-53a A -- 12 for soft starting, 9 for direct-on-line starting
Mechanical endurance of contactor Oper- 30 million --
ating
cycles
Trip class CLASS 5, 10, 15, 20
Permissible switching frequency see manual
Rated ultimate short-circuit breaking capacity Iq
• At 400 V AC kA 50
• At 500 V AC kA 50 202)
Short-circuit protection
• At Iemax = 2 A Integrated, 2 x 13 Ie = 26 A
• At Iemax = 9/12 A Integrated, 2 x 13 Ie = 208 A
1)
DS .... Direct-on-line starters
RS .... Reversing starters
DSS .. Direct-on-line soft starters
RSS .. Reversing soft starters
te ...... Full motor protection (thermal + electronic)
s ....... Electronic switching with semiconductor.
2) Only systems with grounded neutral point permitted.

Siemens IC 10 · 2023 9/31


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for PROFIBUS/PROFINET
General data

Line voltage
380 V AC 400 V AC 440 V AC 480 V AC 500 V AC
Brake voltage with brake actuation 180 V DC1)
Operational voltage V 230/400 AC or 180 DC
Uninterrupted current A < 0.5 at 230/400 V AC, < 0.8 at 180 V DC
Short-circuit protection Yes, 1 A melting fuse
Rectified brake voltage V DC 171 180 198 216 225
Recommended brake coil voltage for Siemens motors V DC 170 ... 200 170 ... 200 184 ... 218 184 ... 218 --
1)
Integrated brake actuation supplies DC power supply for the brake.

Type M200D communications modules


For PROFIBUS For PROFINET
Mechanics and environment
Mounting dimensions (W x H x D) mm 174 x 139 x 40
Permissible ambient temperature
• During operation °C -25 ... +55
• During storage °C -40 ... +70
Weight g 300
Permissible mounting position Vertical, horizontal, lying
Vibration resistance according to IEC 60068-2-6 g 2
Shock resistance
• According to IEC 60068-2-27 g/ms 12/11 half-sine
• Without influencing the contact position g/ms 9.8/5 or 5.9/10
Degree of protection according to IEC 529 IP65
Installation altitude
• Up to 1 000 m No derating
• Up to 2 000 m 1% per 100 m
Cooling Convection
Protection class IEC 536 (DIN VDE 0106-1) 1
Electrical specifications
Control circuit
Operational voltage
• UDC24V-NS V DC 20.4 ... 28.8
• UDC24V-S V DC 20.4 ... 28.8
9

Power consumption from


• UDC24V-NS mA < 300
• UDC24V-S mA < 100

9/32 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
M200D motor starters for PROFIBUS/PROFINET
AC-3e Communications modules, motor starter modules

■ Selection and ordering data

M200D motor starter module M200D motor starter M200D motor starter
PROFIBUS/PROFINET PROFIBUS PROFINET
(without communications module)

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

M200D communications modules for PROFIBUS


Communications module for PROFIBUS 3RK1305-0AS01-0AA0 1 1 unit 42D
M12 connection for communication, 7/8" for 24 V power supply
M200D communications modules for PROFINET
Communications module for PROFINET 3RK1335-0AS01-0AA0 1 1 unit 42D
M12 connection for communication, 7/8" for 24 V power supply
M200D PROFIBUS/PROFINET motor starter modules
Electromechanical starters (with integrated
contactor)
3RK1395-6@S41-@AD@ 1 1 unit 42D
Rated operational current setting range/A Add. price
• 0.15 ... 2 K None
• 1.5 ... 12 L ✓
Direct-on-line starters/reversing starters
• Direct-on-line starters 0 None
• Reversing starters 1 ✓

9
• Direct-on-line starters with manual local operation 2 ✓
• Reversing starters with manual local operation 3 ✓
Brake actuation
• Without brake actuation 0 None
• Brake actuation (230/400 V AC) 3 ✓
• Brake actuation (180 V DC) 5 ✓
Electronic starters (with thyristors)
3RK1395-6@S71-@AD@ 1 1 unit 42D
Rated operational current setting range/A Add. price
• 0.15 ... 2 K None
• 1.5 ... 12 L ✓
Direct-on-line starters/reversing starters
• Direct-on-line starters 0 None
• Reversing starters 1 ✓
• Direct-on-line starters with manual local operation 2 ✓
• Reversing starters with manual local operation 3 ✓
Brake actuation
• Without brake actuation 0 None
• Brake actuation (230/400 V AC) 3 ✓
• Brake actuation (180 V DC) 5 ✓
✓ = Additional price

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 9/33
© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
Software
Motor Starter ES

■ Overview
More information
Industry Mall, see www.siemens.com/product?3ZS1
Technical specifications and system requirements, see
https://support.industry.siemens.com/cs/ww/en/ps/16713/td

Motor Starter ES is used for start-up, parameterization,


diagnostics, documentation and the preventative maintenance
of the motor starters in the SIMATIC ET 200S, ET 200pro,
ECOFAST and M200D product families.
The software program is available in three versions which differ
in their user-friendliness, scope of functions and price.
For detailed information on the Motor Starter ES software, see
page 14/10.

Motor Starter ES for parameterization, monitoring, diagnostics and


testing of motor starters
9

9/34 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
Accessories
For all M200D motor starters

■ Overview

7
1

NSA0_00485a
NSA0_00484
2 4 9 10

5
M 8
3 6

1 Power feeder plug 7 Connection for motor control with AS-i communication
2 Power connection plug 8 AS-Interface M12 feeder
3 Power connecting cable 9 Connection for digital input
(IO communication, 5-pole)
4 Motor connection plug
10 Connection for digital output
5 Motor plug (IO communication, 4- or 5-pole)
6 Motor cable

Power and motor connection on the M200D motor starter Communication link using AS-Interface and digital inputs and outputs
(in this example: M200D for AS-i)

9
13 14 13 14

11 12 15 15
NSA0_00488a

NSA0_00487a

9 10 9 10

9 Connection for digital input 9 Connection for digital input


(IO communication, 5-pole) (IO communication, 5-pole)
10 Connection for digital output 10 Connection for digital output
(IO communication, 4- or 5-pole) (IO communication, 4- or 5-pole)
11 PROFIBUS connection (input) 13 Connection for 24 V supply (infeed)
12 PROFIBUS connection (loop) 14 Connection for 24 V supply (loop)
13 Connection for 24 V supply (infeed) 15 Connection with PROFINET
(input on the left, loop on the right)
14 Connection for 24 V supply (loop)

Communication link using PROFIBUS and digital inputs and outputs Communication link using PROFINET and digital inputs and outputs

Siemens IC 10 · 2023 9/35


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
Accessories
For all M200D motor starters

16 Power bus cable (sold by the meter)


17 Power T terminal connector
18 Power double-T terminal connector

16
17 18 18

ET 200pro
M200D M200D

IC01_00231a
Motors

Power supply to the motors via the power bus with power T and double-T terminal connectors linked by power bus cables, spur lines to the field devices
(motor starters), and power loop-through connections to the motors via motor connecting cables
Power bus Interruption-free thanks to power terminal connectors
The power supply to the field devices (ET 200pro motor starters, In finger-safe connection technology the power T terminal
9

M200D motor starters) is provided via the power bus, in which connectors and power double-T terminal connectors connect
the power T terminal connectors or power double-T terminal the components of a feeder to the power bus. They ensure
connectors are connected by power bus cables. interruption-free operation, i.e. when the components are
plugged in, the power bus is not interrupted.
Feeders
From the terminal connectors, spur lines with Han Q4/2 plugs
lead to the field devices, from which the motors are supplied with
power via motor connecting cables.

9/36 Siemens IC 10 · 2023


© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
Accessories
For all M200D motor starters

■ Selection and ordering data


The accessories listed below represent a basic selection
sorted by:
• Accessories for all M200D motor starters
• Accessories for M200D motor starters for AS-Interface
• Accessories for M200D motor starters for PROFIBUS
• Accessories for M200D motor starters for PROFINET
Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Mountable accessories
M200D protective brackets 3RK1911-3BA00 1 1 unit 42D
Incoming power supply
$ Power feeder plugs
Connector set for power supply, e.g. for connecting to
T terminal connectors, comprising a coupling enclosure,
straight outgoing feeder (with bracket), pin insert for
HAN Q4/2, incl. gland
• 5 male contacts, 2.5 mm2 3RK1911-2BS60 1 1 unit 42D
• 5 male contacts, 4 mm2 3RK1911-2BS20 1 1 unit 42D
• 5 male contacts, 6 mm2 3RK1911-2BS40 1 1 unit 42D
% Power connection plugs
Connector set for energy supply for connection to
M200D motor starters, comprising a cable-end
connector hood, angled outgoing feeder, female insert
for HAN Q4/2, incl. gland
• 5 female contacts, 2.5 mm2, 3RK1911-2BE50 1 1 unit 42D
2 female contacts, 0.5 mm2
• 5 female contacts, 4 mm2, 3RK1911-2BE10 1 1 unit 42D
2 female contacts, 0.5 mm2
• 5 female contacts, 6 mm2, 3RK1911-2BE30 1 1 unit 42D
2 female contacts, 0.5 mm2
% + & Power connecting cables
Assembled at one end with "N" and jumper pin 11 and 12
for plug monitoring, with HAN Q4/2, angled;
open at one end; 5 x 4 mm2

9
• Length 1.5 m 3RK1911-0DC13 1 1 unit 42D
• Length 5.0 m 3RK1911-0DC33 1 1 unit 42D
Motor cables
( Motor connection plugs
Connector set for motor cable for connection to
M200D motor starters, comprising a cable-end connector
hood, angled outgoing feeder, pin insert for HAN Q8/0,
incl. gland
• 8 male contacts, 1.5 mm2 3RK1902-0CE00 1 1 unit 42D
• 6 male contacts, 2.5 mm2 3RK1902-0CC00 1 1 unit 42D
) Motor plugs
Connector set for motor cable for connection to motors,
comprising a cable-end connector hood, straight
outgoing feeder, female insert for HAN 10e,
incl. star jumper, incl. gland
• 7 female contacts, 1.5 mm2 3RK1911-2BM21 1 1 set 42D
• 7 female contacts, 2.5 mm2 3RK1911-2BM22 1 1 set 42D
( + * Motor cables, assembled at one end
For connection to M200D motor starter, HAN Q8/0,
angled, length 5 m
• Motor cables for motor without brake, 4 x 1.5 mm2 3RK1911-0EB31 1 1 unit 42D
• Motor cables for motor without brake with thermistor, 3RK1911-0EF31 1 1 unit 42D
6 x 1.5 mm2
• Motor cables for motor with brake actuation, 3RK1911-0ED31 1 1 unit 42D
brake voltage 400 V AC or 180 V DC, 6 x 1.5 mm2
• Motor cables for motor with brake actuation, 3RK1911-0EG31 1 1 unit 42D
brake voltage 400 V AC or 180 V DC
and thermistor, 8 x 1.5 mm2
• Motor cables for motor with brake actuation, 3RK1911-0EH31 1 1 unit 42D
brake voltage 230 V AC, 6 x 1.5 mm2
• Motor cables for motor with brake actuation, brake 3RK1911-0EE31 1 1 unit 42D
voltage 230 V AC and thermistor, 8 x 1.5 mm2

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 9/37
© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
Accessories
For all M200D motor starters

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Power bus
5 Power T terminal connectors
For 400 V AC, for connection of feeders (e.g. motor
starters) by means of standard round cable at any point
of the power bus, by insulation displacement connection,
used with preassembled bus segments
• 2.5 mm²/4 mm² 3RK1911-2BF01 1 1 unit 42D
• 4 mm²/6 mm² 3RK1911-2BF02 1 1 unit 42D
6 Power double-T terminal connectors
For 400 V AC, for connection of feeders (e.g. motor
starters) by means of standard round cable at any point
of the power bus, by insulation displacement connection,
used with preassembled bus segments, connection of
two motor starters possible
• 4 mm²/6 mm² 3RK1911-2BG02 1 1 unit 42D
Sealing set (comprising 2 seals)
For power T/power double-T terminal connectors
• For power cables with
- Ø 10 ... 13 mm 3RK1911-5BA00 1 1 unit 42D
- Ø 13 ... 16 mm 3RK1911-5BA10 1 1 unit 42D
- Ø 16 ... 19 mm 3RK1911-5BA20 1 1 unit 42D
- Ø 19 ... 22 mm 3RK1911-5BA30 1 1 unit 42D
• Blanking plugs 3RK1911-5BA50 1 1 unit 42D
Further accessories for power connections
Crimping tools for pins/sockets 4 mm2 and 6 mm2 3RK1902-0CW00 1 1 unit 42D

3RK1902-0CW00
Dismantling tools
• For male and female contacts for 9-pole HAN Q4/2 inserts 3RK1902-0AB00 1 1 unit 42D
• For male and female contacts for 9-pole HAN Q8 inserts 3RK1902-0AJ00 1 1 unit 42D
Sealing caps
9

For 9-pole power sockets


• 1 unit per pack 3RK1902-0CK00 1 1 unit 42D
• 10 units per pack 3RK1902-0CJ00 1 10 units 42D

3RK1902-0CK00

* You can order this quantity or a multiple thereof.


9/38 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
Accessories
For all M200D motor starters

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Motor control with I/O communication


M12 plugs, straight 3RK1902-4BA00-5AA0 1 1 unit 42D
Screw fixing, 5-pole screw terminals,
max. 0.75 mm2,
A-coded, max. 4 A

3RK1902-4BA00-5AA0
. M12 plugs, angled 3RK1902-4DA00-5AA0 1 1 unit 42D
Screw fixing, 5-pole screw terminals,
max. 0.75 mm2,
A-coded, max. 4 A

3RK1902-4DA00-5AA0
-, . Control cables, assembled at one end
M12 plug, angled, screw fixing, 5-pole, 5 x 0.34 mm2,
A-coded, black PUR sheath, max. 4 A
• Cable length 1.5 m 3RK1902-4HB15-5AA0 1 1 unit 42D
3RK1902-4H...-5AA0 • Cable length 5 m 3RK1902-4HB50-5AA0 1 1 unit 42D
• Cable length 10 m 3RK1902-4HC01-5AA0 1 1 unit 42D
Control cables, assembled at both ends
Straight M12 plug, straight M12 socket, screw fixing,
3RK1902-4PB15-3AA0 3-pole, 3 x 0.34 mm2,
A-coded, black PUR sheath, max. 4 A
• Cable length 1.5 m 3RK1902-4PB15-3AA0 1 1 unit 42D
Further accessories
Handheld devices 3RK1922-3BA00 1 1 unit 42D
For M200D motor starters (or for ET 200pro and ET 200S
High Feature motor starters) for local operation.
The motor starter-specific serial interface cables must be
ordered separately.
The RS 232 interface cable 3RK1922-2BP00 is used for
the MS M200D.
RS 232 interface cable 3RK1922-2BP00 1 1 unit 42D
Serial data connection between M200D (or ET 200pro)
motor starters and the RS 232 interface of a PC/PG/laptop

9
(with the Motor Starter ES software) or the handheld device
3RK1922-3BA00 3RK1922-3BA00
USB interface cable, 2.5 m 6SL3555-0PA00-2AA0 1 1 unit 368
Serial data connection between M200D (or ET 200pro)
motor starters and the USB interface of a PC/PG/laptop
(with the Motor Starter ES software).
M12 sealing caps 3RK1901-1KA00 100 10 units 42C
For sealing unused M12 input or output sockets
and M12 sockets for PROFIBUS and
PROFINET communications modules
3RK1901-1KA00 (one set contains ten sealing caps)
RONIS SB30 keys 3SU1950-0FB80-0AA0 1 1 unit 41J
Spare key for M200D
for "manual local control" ordering option

3SU1950-0FB80-0AA0

For more connection technology products, see


https://support.industry.siemens.com/cs/ww/en/view/65355810.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 9/39
© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
Accessories
For M200D motor starters for AS-Interface

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Motor control with AS-i communication


+ Control cables, assembled at one end
M12 socket, angled, screw fixing, 4-pole, 4 x 0.34 mm2,
A-coded, black PUR sheath, max. 4 A
3RK1902-4GB50-4AA0 • Cable length 5 m 3RK1902-4GB50-4AA0 1 1 unit 42D
+ M12 sockets, angled 3RK1902-4CA00-4AA0 1 1 unit 42D
For screw fixing, 4-pole screw terminals,
max. 0.75 mm2,
A-coded, max. 4 A

3RK1902-4CA00-4AA0
, AS-Interface M12 feeders
For For Cable length Cable end
flat cable in feeder
AS-i/Uaux M12 socket -- Not 3RK1901-2NR20 1 1 unit 42C
available
M12 1m Not 3RK1901-2NR21 1 1 unit 42C
cable box available
2m Not 3RK1901-2NR22 1 1 unit 42C
available
3RK1901-2NR21
Cable end terminators 3RK1901-1MN00 1 10 units 42C
For sealing of open cable ends (AS-Interface shaped
cable) in IP67

3RK1901-1MN00
AS-Interface shaped cables, see also page 2/76
Material Color Quantity
9

Rubber Yellow (AS- 100 m roll 3RX9010-0AA00 1 1 unit 42C


Interface) 1 km drum 3RX9012-0AA00 1 1 unit 42C
Black 100 m roll 3RX9020-0AA00 1 1 unit 42C
(24 V DC) 1 km drum 3RX9022-0AA00 1 1 unit 42C
3RX90..-0AA00
TPE Yellow (AS- 100 m roll 3RX9013-0AA00 1 1 unit 42C
Interface) 1 km drum 3RX9014-0AA00 1 1 unit 42C
Black 100 m roll 3RX9023-0AA00 1 1 unit 42C
(24 V DC) 1 km drum 3RX9024-0AA00 1 1 unit 42C
TPE special Yellow (AS- 100 m roll 3RX9017-0AA00 1 1 unit 42C
version Interface)
according to Black 100 m roll 3RX9027-0AA00 1 1 unit 42C
UL Class 2 (24 V DC)
PUR Yellow (AS- 100 m roll 3RX9015-0AA00 1 1 unit 42C
Interface) 1 km drum 3RX9016-0AA00 1 1 unit 42C
Black 100 m roll 3RX9025-0AA00 1 1 unit 42C
(24 V DC) 1 km drum 3RX9026-0AA00 1 1 unit 42C

* You can order this quantity or a multiple thereof.


9/40 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
Accessories
For M200D motor starters for AS-Interface

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Further accessories
AS-Interface addressing unit V3.0 3RK1904-2AB02 1 1 unit 42C
• For AS-Interface modules and sensors and
actuators with integrated AS-Interface according
to AS-i specification V3.0
• For setting the AS-i address of standard slaves,
and slaves with extended addressing mode
(A/B slaves)
• With input/output test function and many other
commissioning functions
• Battery operation with four type AA batteries
(IEC LR6, NEDA 15)
• Scope of supply:
- Addressing unit with four batteries
- Addressing cable, with M12 plug to addressing plug
(hollow plug), length 1.5 m
3RK1904-2AB02
M12 addressing cables to M12 3RK1902-4PB15-3AA0 1 1 unit 42D
• Standard M12 cable for addressing slaves with
M12 connection,e.g. K60R modules
3RK1902-4PB15-3AA0 • When using the current version of the 3RK1904-2AB01
addressing unit
• 1.5 m
Equipment manuals
M200D AS-Interface Basic motor starters, see
https://support.industry.siemens.com/cs/ww/en/view/35016496
M200D AS-Interface Standard motor starters, see
https://support.industry.siemens.com/cs/ww/en/view/38722160

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 9/41
© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
Accessories
For M200D motor starters for PROFIBUS

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Motor control with PROFIBUS


M12 plugs, angled
For screw fixing, 5-pole screw terminal,
max. 0.75 mm2, B-coded, no terminating resistor
• / 5 female contacts 3RK1902-1DA00 1 1 unit 42D

3RK1902-1DA00
• 0 5 male contacts 3RK1902-1BA00 1 1 unit 42D

3RK1902-1BA00
Control cables, assembled at one end
M12, screw fixing, angled, B-coded,
no terminating resistor
3RK1902-1G. • / 5 female contacts, 3 m 3RK1902-1GB30 1 1 unit 42D
• / 5 female contacts, 5 m 3RK1902-1GB50 1 1 unit 42D
• / 5 female contacts, 10 m 3RK1902-1GC10 1 1 unit 42D
/ 0 Control cables, assembled at both ends
M12, screw fixing, angled, 5-pole
plug/socket connectors, B-coded,
no terminating resistor
3RK1902-1N.
• 3.0 m 3RK1902-1NB30 1 1 unit 42D
• 5.0 m 3RK1902-1NB50 1 1 unit 42D
• 10.0 m 3RK1902-1NC10 1 1 unit 42D
Further accessories
PROFIBUS trailing cables 6XV1830-3EH10 1 1M 5K2
Max. acceleration 4 m/s2, at least 3 000 000 bending
cycles, bending radius at least 60 mm, 2-core, shielded,
sold by the meter, minimum order quantity 20 m,
9

maximum order quantity 1 000 m


PROFIBUS FC Food bus cables 6XV1830-0GH10 1 1M 5K2
With PE outer sheath for operation in the food and
beverage industry, 2-core, shielded, sold by the meter,
minimum order quantity 20 m, maximum order quantity
1 000 m
PROFIBUS FC Robust bus cables 6XV1830-0JH10 1 1M 5K2
With PUR outer sheath for operation in environments
exposed to chemicals and mechanical loads, 2-core,
shielded, sold by the meter, minimum order quantity
20 m, maximum order quantity 1 000 m
Power cables 6XV1830-8AH10 1 1M 5K2
5-core, 5 x 1.5 mm2, trailing, sold by the meter,
minimum order quantity 20 m, maximum order quantity
1 000 m
Connection for 24 V power supply of the M200D PROFIBUS/PROFINET
See page 9/43
Equipment manual
M200D PROFIBUS/PROFINET motor starters, see
https://support.industry.siemens.com/cs/ww/en/view/38823402

* You can order this quantity or a multiple thereof.


9/42 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Motor starters for use in the field, high degree of protection


SIRIUS M200D motor starters
Accessories
For M200D motor starters for PROFINET

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Motor control with PROFINET


3 M12 plugs, angled
For screw fixing, 4-pole screw terminal,
max. 0.75 mm2, angled, D-coded
• 4 male contacts 3RK1902-2DA00 1 1 unit 42D
3 Control cables, assembled at one end
M12 for screw fixing, angled, 4-pole, D-coded,
• 4 male contacts, 3 m 3RK1902-2HB30 1 1 unit 42D
• 4 male contacts, 5 m 3RK1902-2HB50 1 1 unit 42D
3RK1902-2H.
• 4 male contacts, 10 m 3RK1902-2HC10 1 1 unit 42D
3 Control cables, assembled at both ends
M12 for screw fixing, angled at both ends,
4-pole, D-coded, male contacts at both ends
•3m 3RK1902-2NB30 1 1 unit 42D
3RK1902-2N.
•5m 3RK1902-2NB50 1 1 unit 42D
• 10 m 3RK1902-2NC10 1 1 unit 42D
Further accessories
PROFINET IE FC TP standard cable GP 2 x 2 6XV1840-2AH10 1 1M 5K1
Sold by the meter
PROFINET IE FC TP trailing cable 2 x 2 6XV1840-3AH10 1 1M 5K1
Sold by the meter
PROFINET IE FC TP trailing cable GP 2 x 2 6XV1870-2D 1 1M 5K2
Sold by the meter
PROFINET IE FC TP torsion cable 2 x 2 6XV1870-2F 1 1M 5K2
Sold by the meter
PROFINET IE FC TP marine cable, 4-core 6XV1840-4AH10 1 1M 5K1
Sold by the meter
Power cables 6XV1830-8AH10 1 1M 5K2
5-core, 5 x 1.5 mm2, trailing, sold by the meter, minimum
order quantity 20 m, maximum order quantity 1 000 m

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

9
Connection for 24 V power supply of the M200D PROFIBUS/PROFINET
Plugs
On M200D, 7/8" for screw fixing, angled,
screw terminal, 1.5 mm2
• 1 5 female contacts 3RK1902-3DA00 1 1 unit 42D

3RK1902-3DA00
• 2 5 male contacts 3RK1902-3BA00 1 1 unit 42D

3RK1902-3BA00
1 Supply lines, assembled at one end
7/8" for screw fixing, angled, 1.5 mm2
• 5 female contacts, 3 m 3RK1902-3GB30 1 1 unit 42D
• 5 female contacts, 5 m 3RK1902-3GB50 1 1 unit 42D
• 5 female contacts, 10 m 3RK1902-3GC10 1 1 unit 42D
3RK1902-3G.
1 2 Supply lines, assembled at
both ends
7/8", for screw fixing, angled at both ends,
5-pole plug/socket connectors, 1.5 mm2
3RK1902-3N. •3m 3RK1902-3NB30 1 1 unit 42D
•5m 3RK1902-3NB50 1 1 unit 42D
• 10 m 3RK1902-3NC10 1 1 unit 42D
7/8" sealing caps 6ES7194-3JA00-0AA0 1 10 units 250
1 pack = 10 units

6ES7194-3JA00-0AA0
Equipment manual
M200D PROFIBUS/PROFINET motor starters, see
https://support.industry.siemens.com/cs/ww/en/view/38823402

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 9/43
© Siemens 2023

Motor starters for use in the field, high degree of protection

Notes
9

9/44 Siemens IC 10 · 2023


10
© Siemens 2023

Monitoring and control devices

Price groups SIRIUS 3UG45, 3UG46 monitoring


PG 41B, 41E, 41F, 41H, 41L, 42F, 42J relays for stand-alone installation
10/67 General data
10/2 Introduction 10/69 Line monitoring
SIMOCODE 3UF motor management 10/74 Voltage monitoring
and control devices 10/77 Current monitoring
SIMOCODE pro 3UF7 motor 10/79 Power factor and active current
management and control devices monitoring
10/5 General data Residual-current monitoring
10/12 Basic units 10/82 - Residual-current monitoring relays
10/15 Expansion modules 10/84 - 3UL23 residual-current transformers
10/17 Fail-safe expansion modules 10/85 Insulation monitoring
10/18 Accessories 10/89 Level monitoring
3UF18 current transformers for overload 10/92 Speed monitoring
protection 10/95 Accessories
10/21 Basic units and accessories SIRIUS 3UG48 monitoring relays
for stand-alone installation for IO-Link
10/22 LOGO! logic modules 10/96 General data
Relays 10/99 Line monitoring
Timing relays 10/102 Voltage monitoring
10/23 General data 10/105 Current monitoring
10/24 SIRIUS 3RP25 timing relays, 10/108 Power factor and active current
17.5 mm and 22.5 mm monitoring
10/36 SIRIUS 3RP20 timing relays, 45 mm Residual-current monitoring
10/42 7PV15 timing relays, 17.5 mm 10/112 - Residual-current monitoring relays
3/95 SIRIUS 3RA28 solid-state time-delay 10/84 - 3UL23 residual-current transformers
auxiliary switches for mounting 10/115 Speed monitoring
on 3RT2 contactors and 10/118 Accessories
3RH2 contactor relays SIRIUS 3RS2 temperature monitoring
3/100 SIRIUS 3RA28 function modules for relays
mounting on 3RT2 contactors and 10/119 General data
3RH2 contactor relays 10/127 Basic units
3/96 SIRIUS 3RT19 solid-state time-delay 10/128 Accessories
auxiliary switches for mounting on

10
SIRIUS 3RN2 thermistor motor
3RT1 contactors protection
SIRIUS 3RR21, 3RR22 monitoring
relays for mounting on 3RT2 contactors 10/129 General data
10/47 Current and active current monitoring 10/136 Basic units
SIRIUS 3RR24 monitoring relays 10/137 Accessories
for mounting on 3RT2 contactors Coupling relays and signal converters
for IO-Link 5/1 Coupling relays
10/55 Current and active current monitoring 3/138 3TG10 power relays/miniature
SIRIUS 3UG5 monitoring relays contactors
for stand-alone installation 10/138 SIRIUS 3RS70 signal converters
10/62 DC load monitoring

Siemens IC 10 · 2023
© Siemens 2023

Monitoring and control devices

Introduction

■ Overview

Type SIMOCODE pro C SIMOCODE pro V SIMOCODE pro S SIMOCODE pro V Page
PROFINET General Performance High Performance
General Performance PROFIBUS/PROFINET
Modbus RTU/EtherNet/IP
SIMOCODE pro 3UF7 motor management and control devices
Basic units ✓ ✓ ✓ ✓ 10/12
Current measuring modules ✓ ✓ ✓ ✓ 10/13
Current/voltage measuring modules -- -- -- ✓ 10/13
Operator panels ✓ ✓ ✓ ✓ 10/14
Operator panels with display -- -- -- ✓ 10/14
Expansion modules -- ✓ ✓ ✓ 10/15
Fail-safe expansion modules -- -- -- ✓ 10/17
Current transformers ✓ ✓ ✓ ✓ 10/21
SIMOCODE ES (TIA Portal) ✓ ✓ ✓ ✓ 14/12
SIMOCODE pro block library ✓ ✓ ✓ ✓ 14/15
for SIMATIC PCS 7
✓ Available
-- Not available

Type 3RP25 3RP20 7PV15


Timing relays
Enclosures:
10

• 17.5 mm industry and household ✓ -- ✓


equipment installation
• 22.5 mm industry ✓ -- --
• 45 mm industry -- ✓ --
Monofunction ✓ ✓ ✓
Multifunction ✓ ✓ ✓
Combination voltage ✓ ✓ ✓
Wide voltage range ✓ ✓ ✓
Application:
• Control systems and mechanical ✓ ✓ ✓
engineering
• Infrastructure -- -- ✓
Page 10/24 10/36 10/42
✓ Corresponds to or available
-- Does not correspond to or not available

10/2 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices

Introduction

Type 3UG546 3UG451., 3UG463. 3RR21, 3UG4641 3UG4625 3UG458. 3UG4501 3UG4651 Page
3UG461. 3RR22, with
3UG4621, 3UL23
3UG4622
Monitoring relays
DC load monitoring ✓ -- -- -- -- -- -- -- -- 10/62
Line monitoring -- ✓ -- -- -- -- -- -- -- 10/69
Voltage monitoring -- -- ✓ -- -- -- -- -- -- 10/74
Current monitoring -- -- -- ✓ -- -- -- -- -- 10/47, 10/77
Active current monitoring -- -- -- 3RR22 ✓ ✓ -- -- -- -- 10/47, 10/79
Power factor monitoring -- -- -- -- ✓ -- -- -- -- 10/79
Residual-current monitoring -- -- -- -- -- ✓ -- -- -- 10/82
Insulation monitoring -- -- -- -- -- -- ✓ -- -- 10/85
Level monitoring -- -- -- -- -- -- -- ✓ -- 10/89
Speed monitoring -- -- -- -- -- -- -- -- ✓ 10/92
✓ Available
-- Not available

Type 3UG481. 3UG4832 3RR24 3UG4822 3UG4841 3UG4825 3UG4851 Page


with 3UL23
Monitoring relays for IO-Link
Line monitoring ✓ -- -- -- -- -- -- 10/99
Voltage monitoring -- ✓ -- -- -- -- -- 10/102
Current monitoring -- -- ✓ ✓ -- -- -- 10/55, 10/105
Power factor and active current -- -- ✓ -- ✓ -- -- 10/55, 10/108

10
monitoring
Residual-current monitoring -- -- -- -- -- ✓ -- 10/112
Speed monitoring -- -- -- -- -- -- ✓ 10/115
✓ Available
-- Not available

Type 3RS2 3RN2 3RS70 Page


Temperature monitoring relays
Temperature monitoring ✓ -- -- 10/119
Temperature monitoring relays for IO-Link
Temperature monitoring ✓ -- -- 10/119
for IO-Link
Thermistor motor protection
Thermistor motor protection -- ✓ -- 10/129
Signal converters
Single-range converters -- -- ✓ 10/138
Multi-range converters -- -- ✓ 10/138
Universal converters -- -- ✓ 10/138
✓ Available
-- Not available

Siemens IC 10 · 2023 10/3


© Siemens 2023

Monitoring and control devices

Introduction
Connection methods Ordering notes for multi-unit packaging
The monitoring and control devices are available with screw SIMOCODE pro S, SIRIUS 3RP25 timing relays, SIRIUS 3RS2
or spring-loaded terminals. temperature monitoring relays, and SIRIUS 3RN2 thermistor
motor protection can be ordered in practical and environ-
SIRIUS 3RP25 timing relays, 3UG458 insulation monitoring mentally multi-unit packaging on request.
relays, SIRIUS 3RS2 temperature monitoring relays,
SIRIUS 3RN2 thermistor motor protection and SIRIUS 3RS70 Multi-unit packaging with order code X90
signal converters are available with screw terminals or spring-
loaded terminals (push-in). When ordering products in multi-unit packaging, the article
number of the product concerned must be supplemented with
"-Z" and, in addition, the order code "X90" must be specified.
Screw terminals
Ordering examples:
Spring-loaded terminals, spring-loaded terminals • 3RP2505-1AB30-Z X90;
(push-in) Order quantity 16 items  Delivery of one pack containing
16 items
The connection method is indicated in the
corresponding tables by the respective symbol shown • 3RP2505-1BB30-Z X90;
on orange backgrounds. Order quantity 12 items  Delivery of one pack containing
12 items
"Increased safety" type of protection EEx e/d according to For more information, see page 16/7.
ATEX Directive 2014/34/EU
The communication-capable, modularly designed SIMOCODE pro
motor management system (SIRIUS Motor Management and
Control Devices) protects motors of types of protection EEx e and
EEx d in hazardous areas.
The SIRIUS 3RN2 thermistor motor protection relay protects
motors with types of protection EEx e and EEx d in hazardous
areas.
ATEX approval for operation in hazardous areas
The SIRIUS SIMOCODE pro 3UF7 motor management system is
certified for the protection of motors in hazardous areas
according to
• ATEX Ex I (M2); equipment group I, category M2 (mining)
• ATEX Ex II (2) GD; equipment group II, category 2 in area GD
The SIRIUS 3RN2011, 3RN2012-...30, 3RN2013 and 3RN2023
thermistor motor protection relays for PTC sensors are certified
according to ATEX Ex II (2) G and D for environments with
explosive gas or dust loads.
10

10/4 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
General data

■ Overview
SIMOCODE pro offers, for example:
• Multifunctional, electronic full motor protection that is
independent of the automation system
• Integrated control functions instead of hardware for the motor
control
• Detailed operating, service and diagnostics data
• Open communication via PROFIBUS DP, PROFINET/OPC UA,
Modbus RTU or EtherNet/IP
• Safety relay function for the fail-safe disconnection of motors
up to SIL 3 according to IEC 61508, IEC 62061 or PL e
according to ISO 13849-1
• SIMOCODE ES is the software package for SIMOCODE pro
parameterization, startup and diagnostics, see page 14/12.
Device series
Basic Performance with SIMOCODE pro C

SIMOCODE pro S and SIMOCODE pro V


The compact system for direct-on-line starters and reversing
starters or for controlling a motor starter protector.
More information General Performance with SIMOCODE pro S or
Homepage, see www.siemens.com/sirius-simocode SIMOCODE pro V PN GP
Industry Mall, see www.siemens.com/product?3UF7 The smart system for direct-on-line, reversing, and star-delta
TIA Selection Tool Cloud (TST Cloud) (wye-delta) starters or for controlling a motor starter protector or
• For SIMOCODE pro S, see soft starter. Its expandability with an expansion module/multi-
www.siemens.com/tstcloud/?node=SimocodeProS
• For SIMOCODE pro V, see function module provides comprehensive input/output project
www.siemens.com/tstcloud/?node=SimocodeProV data volume, precise ground-fault detection via the 3UL23
residual-current transformers and temperature measurement.
SIMOCODE pro is a flexible, modular motor management
system for motors with constant speeds in the low-voltage High Performance with SIMOCODE pro V
performance range. It optimizes the connection between I&C The variable system with all control functions and with the
and motor feeder, increases plant availability and allows possibility of expanding the inputs, outputs and functions of the
significant savings to be made for installation, commissioning, system at will using expansion modules.
operation and preventive maintenance of a system.

PROFINET IO/OPC UA ETHERNET/IP PROFIBUS MODBUS RTU

10
Current/voltage measuring module

Operator panel with display

Performance
Max. 5/7 expansion modules High

Safety
SIMOCODE pro V PN SIMOCODE pro V EIP SIMOCODE pro V PB SIMOCODE pro V MR

Extended control functions


(e.g. positioner, pole-changing starter)

Current measuring module


Performance

Operator panel
General

1 expansion module
IC01_00548b

Basic control functions SIMOCODE pro V PN GP SIMOCODE pro S


(e.g. direct-on-line/reversing start)

Device series

Siemens IC 10 · 2023 10/5


© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
General data

Basic system Optional expansions


Current Basic unit Operator Multifunction module
measuring module panel
SIMOCODE pro S

PROFIBUS

Functions
Optional expansions
One option can be selected
1 2 3
Basic system
Current Basic unit Operator Ground-fault Temperature Digital module
measuring module panel module module Standard
SIMOCODE pro V PN GP

PROFINET/
OPC UA

Functions
IC01_00532b
10

Basic system Optional expansions


Current/voltage Basic unit Operator Earth-fault Temperature Digital modules Analog
measuring module panel module module Standard Fail-safe module
SIMOCODE pro V

Communication
Functions

Communication at basic unit via:


PROFIBUS/PROFIsafe Modbus RTU
PROFINET/PROFIsafe EtherNet/IP
OPC UA

System structure

10/6 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
General data

Expansion possibilities SIMOCODE pro C SIMOCODE pro S SIMOCODE pro V SIMOCODE pro V
Basic Performance General Performance General Performance High Performance
PROFIBUS PROFIBUS PROFINET GP PROFIBUS/ PROFINET/
Modbus RTU EtherNet/IP
Operator panels ✓ ✓ ✓ ✓ ✓
Operator panels -- -- -- ✓ ✓
with display
Current measuring modules ✓ ✓ ✓ ✓ ✓
Current/voltage measuring modules -- -- -- ✓ ✓
Expansion modules:
• Digital modules -- -- 12) 2 2
1)
• Fail-safe digital modules -- -- -- 1 1
• Analog modules -- -- -- 1 2
• Ground-fault modules -- -- 1 1 1
• Temperature modules -- -- 1 1 2
• Multifunction modules -- 1 -- -- --

✓ Available 1) The fail-safe digital module can be used instead of one of the two
-- Not available digital modules.
2) Only monostable version can be used.

Per feeder each system always comprises one basic unit and added to the SIMOCODE pro V and SIMOCODE pro S by
one separate current measuring module. The two modules are means of optional expansion modules, thus supplementing the
connected together electrically through the system interface inputs and outputs already existing on the basic unit. With the
with a connecting cable and can be mounted mechanically DM-F Local and DM-F PROFIsafe fail-safe digital modules it is
connected as a unit (one behind the other) or separately also possible to integrate the fail-safe disconnection of motors in
(side by side). The motor current to be monitored is decisive the SIMOCODE pro V motor management system.
only for the choice of the current measuring module.
All modules are connected by connecting cables.
An operator panel for mounting in the control cabinet door is The connecting cables are available in various lengths.
optionally connectable through a second system interface on The maximum distance between the modules (e.g. between
the basic unit. Both the current measuring module and the the basic unit and the current measuring module) must not
operator panel are electrically supplied by the basic unit through exceed 2.5 m. The total length of all the connecting cables per
the connecting cable. More inputs, outputs and functions can be system interface of the basic unit may be up to 3 m.

Article number scheme

10
Product versions Article number
SIMOCODE pro motor management system 3UF7 @@@– 1 @@0 @– 0
Type of unit/module e.g. 0 = basic unit @
Functional version of the module e.g. 20 = SIMOCODE pro S @@
Connection type of the current transformer e.g. A = through-hole technology @
Voltage version e.g. B = 24 V DC @
Enclosure color e.g. 1 = titanium gray @
Example 3UF7 0 2 0 – 1 A B 0 1 – 0
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

Siemens IC 10 · 2023 10/7


© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
General data

■ Benefits
General customer benefits Recording of measuring curves
• Integrating the whole motor feeder into the process control by SIMOCODE pro can record measuring curves and therefore is
means of PROFIBUS DP, PROFINET/OPC UA, Modbus RTU or able, for example, to present the progression of motor current
EtherNet/IP significantly reduces the wiring between the motor during motor startup.
feeder and the PLC
• Decentralization of the automated processes by means of Flexible motor control implemented with integrated control
configurable control and monitoring functions in the feeder functions (instead of comprehensive hardware interlocks)
saves resources in the automation system and ensures full Many predefined motor control functions have already been
functionality and protection of the feeder even if the I&C or bus integrated into SIMOCODE pro, including all necessary logic
system fails operations and interlocks:
• The acquisition and monitoring of operating, service and • Overload relays
diagnostics data in the feeder and process control system • Direct-on-line and reversing starters
increases plant availability as well as preventive maintenance
and service-friendliness • Star-delta (wye-delta) starters (also with direction reversal)
• The high degree of modularity allows users to perfectly • Two speeds, motors with separate windings (pole-changing
implement their plant-specific requirements for each motor starter); also with direction reversal
feeder • Two speeds, motors with separate Dahlander windings
• The SIMOCODE pro system offers functionally graded and (also with direction reversal)
space-saving solutions for each customer application • Positioner actuation
• The replacement of the control circuit hardware with • Solenoid valve actuation
integrated control functions decreases the number of • Actuation of a motor starter protector
hardware components and wiring required and in this way
limits stock keeping costs and potential wiring errors • Soft starter actuation (also with direction reversal)
• The use of electronic full motor protection permits better These control functions are predefined in SIMOCODE pro and
utilization of the motors and ensures long-term stability of the can be freely assigned to the inputs and outputs of the device
tripping characteristic and reliable tripping even after years of (including the PROFIBUS/PROFINET process image).
service
These predefined control functions can also be flexibly adapted
• Thanks to the precision of the current, voltage, power and to each customized configuration of a motor feeder by means of
energy measurements (especially those acquired by the freely configurable logic modules (truth tables, counters, timers,
2nd-generation current/voltage measuring modules), costs edge evaluation, etc.) and with the help of standard functions
can be internally allocated with a high degree of accuracy (power failure monitoring, emergency start, external faults, etc.),
Multifunctional, electronic full motor protection without additional auxiliary relays being necessary in the control
for rated motor currents up to 820 A circuit.

SIMOCODE pro offers comprehensive protection of the motor SIMOCODE pro makes a lot of additional hardware and wiring in
feeder by means of a combination of different, multi-step and the control circuit unnecessary, which results in a high level of
delayable protection and monitoring functions: standardization of the motor feeder in terms of its design and
circuit diagrams.
10

• Inverse-time delayed electronic overload protection


(CLASS 5E to 40E)
• Thermistor motor protection
• Phase failure/asymmetry protection
• Stall protection
• Monitoring of adjustable limit values for the motor current
• Voltage and power monitoring
• Monitoring of the power factor (motor idling/load shedding)
• Ground-fault monitoring
• Temperature monitoring, e.g. via Pt100/Pt1000
• Monitoring of operating hours, downtime and number
of starts, etc.

10/8 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
General data
Detailed operating, service and diagnostics data Communication
SIMOCODE pro makes different operational, service and SIMOCODE pro has either an integrated PROFIBUS DP
diagnostics data available and helps to detect potential faults in or Modbus RTU interface (SUB-D or terminal connection)
time and to prevent them by means of preventative measures. or a PROFINET or EtherNet/IP interface (2 x RJ45).
In the event of a malfunction, a fault can be diagnosed, localized
and rectified very quickly – there are no or very short downtimes. Fail-safe disconnection through PROFIBUS or PROFINET with
the PROFIsafe profile is also possible in conjunction with
Operating data a fail-safe controller (F-CPU) and the DM-F PROFIsafe fail-safe
• Motor switching state derived from the current flow in the main digital module.
circuit SIMOCODE pro PROFIBUS
• All phase currents SIMOCODE pro PROFIBUS supports, for example:
• All phase voltages and phase-to-phase voltages • Cyclic services (DPV0) and acyclic services (DPV1)
• Active power, apparent power and power factor • Extensive diagnostics and hardware interrupts
• Phase asymmetry and phase sequence • Time stamp with high timing precision (SIMATIC S7)
• Ground-fault current for SIMOCODE pro V
• Frequency • DPV1 communication after the Y-Link
• Time to trip SIMOCODE pro PROFINET
• Motor temperature
SIMOCODE pro PROFINET supports, for example:
• Remaining cooling time etc.
• Line and ring bus topology (for 2-port devices with
Service data an integrated switch)
• Motor operating hours • Media redundancy via MRP protocol (for 2-port devices with
• Motor stop times an integrated switch)
• Number of motor starts • Operating, service and diagnostics data via standard
web browser
• Number of overload trips
• OPC UA server for open communication with visualization and
• Interval for compulsory testing of the enabling circuits I&C system
• Energy consumed • NTP-synchronized time
• Internal comments stored in the device etc. • Interval function and measured values for power management
Diagnostics data via PROFIenergy
• Numerous detailed early warning and fault messages • Module exchange without PC/memory module through
proximity detection
• Internal device fault logging with time stamp
• Extensive diagnostics and maintenance alarms
• Time stamping of freely selectable status, alarm or fault
messages etc. System redundancy with SIMOCODE pro PROFINET
Easy operation and diagnostics All SIMOCODE PROFINET devices support the system
redundancy mechanisms of PROFINET IO and therefore can
Operator panel be operated directly on fault-tolerant systems such as

10
The operator panel is used to control the motor feeder and can SIMATIC S7-400 H. As such, SIMOCODE pro can provide
replace all conventional pushbuttons and indicator lights to save decisive added value also for the field level of plants in which
space. It makes SIMOCODE pro or the feeder directly operable plant availability and control system redundancy are priorities.
in the control cabinet. It features all the status LEDs available on SIMOCODE pro Modbus RTU
the basic unit and externalizes the system interface for simple
parameterization or diagnostics on a PC/PG. SIMOCODE pro Modbus RTU supports, for example:
Operator panel with display • Communication at 1 200/2 400/4 800/9 600/19 200 or
57 600 baud
As an alternative to the 3UF720 standard operator panel for • Access to freely parameterizable process image via
SIMOCODE pro V, a 3UF721 operator panel with display is also Modbus RTU
available. This can additionally indicate current measured
values, operating and diagnostics data or status information of • Access to all operating, service and diagnostics data via
the motor feeder at the control cabinet. The pushbuttons of the Modbus RTU
operator panel can be used to control the motor. Furthermore, SIMOCODE pro EtherNet/IP
it is possible to set parameters such as rated motor current,
limit values, etc. directly via the operator panel with display SIMOCODE pro EtherNet/IP supports, for example:
(with SIMOCODE pro V PROFIBUS as of E15, SIMOCODE pro V • Line and ring bus topology thanks to an integrated switch
Modbus RTU as of E03 and with all SIMOCODE pro V PROFINET
and EtherNet/IP). • Ring structures via Device Level Ring (DLR) protocol
• Operating, service and diagnostics data via standard
web browser
• NTP-synchronized time
• Parameter assignment via SIMOCODE ES V14 or higher –
via local device interface and Ethernet

Siemens IC 10 · 2023 10/9


© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
General data
Notes on security Advantages from integrated energy management
In order to protect plants, systems, machines and networks
against cyber threats, it is necessary to implement –
and continuously maintain – a holistic, state-of-the-art
industrial security concept. Siemens products and solutions
represent only one component of such a concept. Ready for Ready for
SIMATIC
siemens.com/ SIMATIC
For more information about the subject of Industrial Security, Energy Suite
see www.siemens.com/industrialsecurity. energysuite Energy Suite

Autonomous operation As an integrated option for the TIA Portal, the SIMATIC Energy
An essential feature of SIMOCODE pro is the autonomous Suite couples energy management with automation efficiently,
execution of all protection and control functions, even when making energy consumption at your production facility
communication to the I&C system is interrupted. This means that transparent.
even in the event of bus system or automation system failure, full Thanks to the simplified configuration of energy-measuring
functionality of the feeder is ensured or a specific behavior can components, e.g. SIMOCODE pro V, configuration effort is also
be parameterized in case of such a fault, e.g. targeted shutdown clearly reduced.
of the feeder or execution of particular parameterized control
mechanisms (such as reversal of the direction of rotation). Thanks to end-to-end connection with higher-level energy
management systems or cloud-based services, you can
seamlessly expand the recorded energy data to create a
cross-site energy management system.
The advantages at a glance:
• Automatic generation of energy management data
• Integration into TIA Portal and into automation
• Simple configuration
For more information, see page 1/3 or
www.siemens.com/energysuite.

■ Application
SIMOCODE pro is often used for automated processes where Safety technology for SIMOCODE pro
plant downtimes are very expensive (e.g. chemical, oil/gas,
water/wastewater, steel or cement industries) and where The safe disconnection of motors in the process industry is
it is important to prevent plant downtimes through detailed becoming increasingly important as the result of new and
operational, service and diagnostics data or to localize faults revised standards and requirements in the safety technology
very quickly when they occur. field.
With the DM-F Local and DM-F PROFIsafe fail-safe expansion
SIMOCODE pro is modular and space-saving and suited modules it is easy to integrate functions for fail-safe
especially for operation in motor control centers (MCCs) disconnection into the SIMOCODE pro V motor management
in the process industry and for power plant technology. system while retaining service-proven concepts. The strict
10

• Protection and control of motors in hazardous areas for types separation of safety functions and operational functions proves
of protection EEx e/d according to ATEX Directive 2014/34/EU particularly advantageous for planning, configuring and
- With heavy starting (paper, cement, metal and water construction. Seamless integration into the motor management
industries) system leads to greater transparency for diagnostics and during
- In high-availability plants (chemical, oil, raw material operation of the system.
processing industries, power plants)
Suitable components for this purpose are the DM-F Local and
• Dry-running protection of centrifugal pumps based on active DM-F PROFIsafe fail-safe expansion modules, depending on the
power monitoring for type of protection Ex b requirements:
Use of SIMOCODE pro 3UF7 with IE3 and IE4 motors • The DM-F Local fail-safe digital module for when direct
assignment between a fail-safe hardware shutdown signal
Note: and a motor feeder is required, or
When using the SIMOCODE pro 3UF7 in conjunction with highly • The DM-F PROFIsafe fail-safe digital module for when
efficient IE3 and IE4 motors, please observe the information on a fail-safe controller (F-CPU) creates the signal for
dimensioning and configuring, see Application Manual. disconnection and transmits it in a fail-safe manner
For more information, see page 1/8. through PROFIBUS/PROFIsafe or PROFINET/PROFIsafe to
the motor management system

10/10 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
General data
Dry-running protection of centrifugal pumps with SIMOCODE pro in hazardous areas
With special versions of the current/voltage measuring modules,
SIMOCODE pro enables dry-running protection of centrifugal
pumps through active power monitoring and motor switch-off.
This applies to centrifugal pumps with progressive flow
characteristics, which are also suitable for pumping flammable
media and are also installed in hazardous areas. If the active
Video: Dry-running protection redefined with SIMOCODE pro power, and thus the flow rate, falls below a minimum value, the
motor – and thus the centrifugal pump – is switched off. When
determining the limit values to be monitored, the user is
supported by a menu-guided teach-in process in the
engineering software.

■ Technical specifications
More information
Technical specifications, see Application Manual for controls with IE3 and IE4 motors, see
https://support.industry.siemens.com/cs/ww/en/ps/16337/td https://support.industry.siemens.com/cs/ww/en/view/94770820
Manual Collection "SIMOCODE pro", see Configuration Manual for load feeders, see
https://support.industry.siemens.com/cs/ww/en/view/109743951 https://support.industry.siemens.com/cs/ww/en/view/39714188
Manual for SIMOCODE pro fail-safe digital modules, see
https://support.industry.siemens.com/cs/ww/en/view/50564852

■ More information
Configuration instructions Types of protection EEx e and EEx d
When using an operator panel with display, please note that the The overload protection and the thermistor motor protection of
type and number of expansion modules that can be connected the SIMOCODE pro system comply with the requirements for
are limited for the use of a SIMOCODE pro V PROFIBUS basic overload protection of explosion-proof motors to the type of
unit (with product version lower than E15) or SIMOCODE pro V protection:
Modbus RTU (with product version lower than E03), see • EEx d "Flameproof enclosure" e.g. according to IEC 60079-1
• TIA Selection Tool • EEx e "Increased safety" e.g. according to IEC 60079-7
• SIMOCODE pro Manual Collection
When using SIMOCODE pro devices with a 24 V DC control
Protective separation voltage, electrical separation must be ensured using a battery or
a safety transformer according to IEC 61558-2-6.
All circuits in SIMOCODE pro are safely isolated from each other EC type-examination certificate: BVS 06 ATEX F 001
according to IEC 60947-1. That is, they are designed with Test report: BVS PP 05.2029 EC.
doubled clearance and creepage distances. In the event

10
of a fault, therefore, no parasitic voltages can be formed in Type of protection Ex b
neighboring circuits. The notes of the test report No. A0258 must
be complied with. The function for dry-running protection of centrifugal pumps in
hazardous areas complies with the requirements of the following
type of protection:
• Ex b "Control of ignition source", ignition protection system b1,
e.g. according to EN 80079-37
SIMOCODE pro is registered for the dry-running protection of
centrifugal pumps by means of active power monitoring
according to both ATEX and IEC Ex.

Siemens IC 10 · 2023 10/11


© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
Basic units IE3 ready IE4 ready IE3/IE4 ready

■ Selection and ordering data


Multi-unit packaging Version Screw terminals PU PS* PG
for SIMOCODE pro S, (UNIT,
see page 16/7. SET, M)
Article No. Price
per PU
SIMOCODE pro PROFIBUS
SIMOCODE pro C
PROFIBUS DP interface, 12 Mbps, RS 485
4 I/3 O freely configurable, input for thermistor connection,
monostable relay outputs
Rated control supply voltage Us:
• 24 V DC 3UF7000-1AB00-0 1 1 unit 42J
• 110 ... 240 V AC/DC 3UF7000-1AU00-0 1 1 unit 42J

3UF7000-1AB00-0
SIMOCODE pro S
PROFIBUS DP interface, 1.5 Mbps, RS 485
4 I/2 O freely configurable, input for thermistor connection,
monostable relay outputs, can be expanded
by a multifunction module
Note: The connecting cable to the current measuring
module must be at least 15 cm.
Rated control supply voltage Us:
3UF7020-1AU01-0 • 24 V DC 3UF7020-1AB01-0 1 1 unit 42J
• 110 ... 240 V AC/DC 3UF7020-1AU01-0 1 1 unit 42J
SIMOCODE pro V
PROFIBUS DP interface, 12 Mbps, RS 485
4 I/3 O freely configurable, input for thermistor connection,
monostable relay outputs, can be expanded by
expansion modules
Rated control supply voltage Us:
• 24 V DC 3UF7010-1AB00-0 1 1 unit 42J
• 110 ... 240 V AC/DC 3UF7010-1AU00-0 1 1 unit 42J
3UF7010-1AB00-0
SIMOCODE pro PROFINET
SIMOCODE pro V PROFINET GP
ETHERNET/PROFINET IO,
OPC UA server and web server, 100 Mbps,
PROFINET system redundancy,
4 I/3 O freely configurable, input for
10

thermistor connection, monostable relay outputs,


can be expanded by expansion module,
web server in German/English/Chinese/Russian
2 x connection to bus through RJ45
3UF7011-1AB00-1 Media Redundancy Protocol
Rated control supply voltage Us:
• 24 V DC 3UF7011-1AB00-1 1 1 unit 42J
• 110 ... 240 V AC/DC 3UF7011-1AU00-1 1 1 unit 42J
1 x connection to bus through RJ45
Rated control supply voltage Us:
• 24 V DC 3UF7011-1AB00-2 1 1 unit 42J
• 110 ... 240 V AC/DC 3UF7011-1AU00-2 1 1 unit 42J
SIMOCODE pro V PROFINET
ETHERNET/PROFINET IO,
OPC UA server and web server, 100 Mbps,
2 x connection to bus through RJ45, PROFINET system
redundancy, Media Redundancy Protocol, 4 I/3 O freely
configurable, input for thermistor connection, monostable
relay outputs, can be expanded by expansion modules,
web server in German/English/Chinese/Russian
Rated control supply voltage Us:
• 24 V DC 3UF7011-1AB00-0 1 1 unit 42J
3UF7011-1AB00-0
• 110 ... 240 V AC/DC 3UF7011-1AU00-0 1 1 unit 42J

* You can order this quantity or a multiple thereof.


10/12 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
IE3 ready IE4 ready IE3/IE4 ready Basic units

Version Current setting Width Screw terminals PU PS* PG


(UNIT,
Article No. Price SET, M)
A mm per PU
SIMOCODE pro Modbus RTU
SIMOCODE pro V Modbus RTU
Modbus RTU interface, 57.6 Kbps, RS 485,
4 I/3 O freely configurable,
input for thermistor connection,
monostable relay outputs,
can be expanded by expansion modules
Rated control supply voltage Us:
• 24 V DC 3UF7012-1AB00-0 1 1 unit 42J
• 110 ... 240 V AC/DC 3UF7012-1AU00-0 1 1 unit 42J
3UF7012-1A.00-0
SIMOCODE pro EtherNet/IP
SIMOCODE pro V EtherNet/IP
EtherNet/IP interface, web server, 100 Mbps,
2 x connection to bus through RJ45,
DLR media redundancy,
4 I/3 O freely configurable,
input for thermistor connection,
monostable relay outputs,
can be expanded by expansion modules,
web server in German/English/Chinese/Russian
Rated control supply voltage Us:
3UF7013-1AB00-0 • 24 V DC 3UF7013-1AB00-0 1 1 unit 42J
• 110 ... 240 V AC/DC 3UF7013-1AU00-0 1 1 unit 42J
SIMOCODE pro current or current/voltage measuring modules
Current measuring modules
• Straight-through transformers 0.3 ... 3 45 3UF7100-1AA00-0 1 1 unit 42J
2.4 … 25 45 3UF7101-1AA00-0 1 1 unit 42J
10 ... 100 55 3UF7102-1AA00-0 1 1 unit 42J
20 ... 200 120 3UF7103-1AA00-0 1 1 unit 42J
• Busbar connection1) 20 ... 200 120 3UF7103-1BA00-0 1 1 unit 42J
63 ... 630 145 3UF7104-1BA00-0 1 1 unit 42J

3UF7103-1AA00-0
2nd-generation current/voltage measuring modules
for SIMOCODE pro V2)

10
Voltage measuring up to 690 V,
measured values with increased accuracy,
power, power factor and frequency monitoring
• Straight-through transformers 0.3 ... 4 45 3UF7110-1AA01-0 1 1 unit 42J
3 ... 40 45 3UF7111-1AA01-0 1 1 unit 42J
10 ... 115 55 3UF7112-1AA01-0 1 1 unit 42J
20 ... 200 120 3UF7113-1AA01-0 1 1 unit 42J
1)
3UF7110-1AA01-0 • Busbar connection 20 ... 200 120 3UF7113-1BA01-0 1 1 unit 42J
63 ... 630 145 3UF7114-1BA01-0 1 1 unit 42J
Current/voltage measuring modules for dry-running
protection of centrifugal pumps in hazardous areas2)3)4)
• Straight-through transformers 0.3 ... 4 45 3UF7120-1AA01-0 1 1 unit 42J
3 ... 40 45 3UF7121-1AA01-0 1 1 unit 42J
10 ... 115 55 3UF7122-1AA01-0 1 1 unit 42J
20 ... 200 120 3UF7123-1AA01-0 1 1 unit 42J
• Busbar connection1) 20 ... 200 120 3UF7123-1BA01-0 1 1 unit 42J
63 ... 630 145 3UF7124-1BA01-0 1 1 unit 42J
3UF7123-1AA01-0
1)
One terminal parts kit 3RT1955-4PA00 or 3RT1966-4PA00 (see Note:
page 10/20) is included in the scope of supply for connection
to a contactor. SIMOCODE pro V basic unit in a hardened version via
2)
When installing the basic unit on a current/voltage measuring module, SIPLUS extreme upon request.
the connecting cable must be at least 15 cm long.
3)
The current/voltage measuring modules for dry-running protection require
SIMOCODE pro V PROFIBUS basic units as of product version E16,
SIMOCODE pro V PROFINET as of product version E13 or
SIMOCODE pro V EtherNet/IP as of product version E04.
4)
When using an operator panel with display with the current/voltage
measuring modules for dry-running protection, an operator panel
with display as of product version E03 is required.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 10/13
© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
Basic units IE3 ready IE4 ready IE3/IE4 ready

Version Screw terminals PU PS* PG


(UNIT,
Article No. Price SET, M)
per PU
SIMOCODE pro operator panels
Operator panels
Installation in control cabinet door or front plate, 3UF7200-1AA01-0 1 1 unit 42J
for plugging into all SIMOCODE pro basic units,
ten LEDs for status indication and freely assignable
buttons for controlling the motor, titanium gray

3UF7200-1AA01-0

Operator panels with display for SIMOCODE pro V


Installation in control cabinet door or front plate, for
plugging into SIMOCODE pro V, seven LEDs for status
indication and user-assignable buttons for controlling the
motor, multilingual display, e.g. for indication of measured
values, status information or fault messages, titanium gray
• English/German/French/Spanish/Portuguese/ 3UF7210-1AA01-0 1 1 unit 42J
Italian/Polish/Finnish
3UF7210-1.A01-0
• English/Chinese/Russian/Korean 3UF7210-1BA01-0 1 1 unit 42J
10

* You can order this quantity or a multiple thereof.


10/14 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
Expansion modules

■ Selection and ordering data


Version Screw terminals PU PS* PG
(UNIT,
Article No. Price SET, M)
per PU
Expansion modules for SIMOCODE pro V
With SIMOCODE pro V, it is possible to expand the type
and number of inputs and outputs in steps. Each expansion
module has two system interfaces on the front. Through the
one system interface the expansion module is connected to
the system interface of the SIMOCODE pro V using
a connecting cable; through the second system interface,
further expansion modules or the operator panel can be
connected. The power supply for the expansion modules is
provided by the connecting cable through the basic unit.
Notes:
The SIMOCODE pro V PN GP basic unit can be used
with the 3UF7300-1A.00-0 monostable digital module,
the 3UF7510-1AA00-0 ground-fault module,
or the 3UF7700-1AA0-0 temperature module.
Please order connecting cable separately, see page 10/18.
Digital modules
Up to two digital modules can be used to add additional
binary inputs and relay outputs to the basic unit. The input
circuits of the digital modules are supplied from an external
power supply.
Four binary inputs and two relay outputs,
up to two digital modules can be connected
Relay outputs Input voltage
Monostable 24 V DC 3UF7300-1AB00-0 1 1 unit 42J
3UF7300-1AB00-0 110 ... 240 V AC/DC 3UF7300-1AU00-0 1 1 unit 42J
Bistable 24 V DC 3UF7310-1AB00-0 1 1 unit 42J
110 ... 240 V AC/DC 3UF7310-1AU00-0 1 1 unit 42J

Analog modules
By means of the analog module, the basic unit can be 3UF7400-1AA00-0 1 1 unit 42J
optionally expanded by analog inputs and outputs
(0/4 ... 20 mA).
Two inputs (passive) for input and one output for output of
0/4 ... 20 mA signals, max. one analog module can be
connected per pro V PB/MB RTU basic unit and max. two
analog modules per pro V PN/EIP basic unit

10
3UF7400-1AA00-0

Ground-fault modules
Ground-fault monitoring using 3UL23 residual-current 3UF7510-1AA00-0 1 1 unit 42J
transformers and ground-fault modules is used in cases
where precise detection of the ground-fault current is
required or power systems with high impedance are
grounded.
With the ground-fault module, it is possible to determine
the precise fault current as a measured value, and to
define freely selectable warning and trip limits in a wide
range from 30 mA ... 40 A.
3UF7510-1AA00-0 One input for connecting a 3UL23 residual-current
transformer, up to one ground-fault module can be
connected
Note:
For corresponding residual-current transformers,
see page 10/84.
Temperature modules
Irrespective of the thermistor motor protection of the basic 3UF7700-1AA00-0 1 1 unit 42J
units, up to an additional three analog temperature sensors
can be evaluated using a temperature module.
Sensor types: Pt100/Pt1000, KTY83/KTY84 or NTC
Three inputs for connecting up to three analog temperature
sensors, up to one temperature module can be connected
per pro V PB/MB RTU basic unit and up to two temperature
modules per pro V PN/EIP basic unit

3UF7700-1AA00-0

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 10/15
© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
Expansion modules

Multi-unit packaging, Version Screw terminals PU PS* PG


see page 16/7. (UNIT,
Article No. Price SET, M)
per PU
Expansion modules for SIMOCODE pro S
With SIMOCODE pro S, it is possible to expand the type
and number of inputs and outputs. The expansion module
has two system interfaces on the front. Through the one
system interface the expansion module is connected
to the system interface of the SIMOCODE pro S using
a connecting cable; through the second system interface,
the operator panel can be connected. The power supply for
the expansion module is provided by the connecting cable
through the basic unit.
Note:
Please order connecting cable separately, see page 10/18.

Multifunction modules
The multifunction module is the expansion module of
the SIMOCODE pro S device series with the following
functions:
• Digital module function with four digital inputs and two
monostable relay outputs
• Ground-fault module function with an input for the
connection of a 3UL23 residual-current transformer with
freely selectable warning and trip limits in a wide zone of
30 mA ... 40 A
3UF7600-1AU01-0 • Temperature module function with an input for connecting
an analog temperature sensor Pt100, Pt1000, KTY83,
KTY84, or NTC
Max. one multifunction module can be connected per pro S
basic unit
Input voltage of the digital inputs:
• 24 V DC 3UF7600-1AB01-0 1 1 unit 42J
• 110 ... 240 V AC/DC 3UF7600-1AU01-0 1 1 unit 42J
10

* You can order this quantity or a multiple thereof.


10/16 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
Fail-safe expansion modules

■ Selection and ordering data


Version Screw terminals PU PS* PG
(UNIT,
Article No. Price SET, M)
per PU
Fail-safe expansion modules for SIMOCODE pro V
Thanks to the fail-safe expansion modules, SIMOCODE pro V
can be expanded with the function of a safety relay for the
fail-safe disconnection of motors. A maximum of one
fail-safe digital module can be connected; it can be used
instead of a digital module.
The fail-safe expansion modules are equipped likewise with
two system interfaces at the front for making the connection
to other system components. Unlike other expansion
modules, power is supplied to the modules through
a separate terminal connection.
Note:
Please order connecting cable separately, see page 10/18.

DM-F Local fail-safe digital modules


For fail-safe disconnection using a hardware signal
Two relay enabling circuits, joint switching; two relay
outputs, common potential disconnected fail-safe; inputs
for sensor circuit, start signal, cascading and feedback
circuit, safety function adjustable using DIP switches
Rated control supply voltage Us:
• 24 V DC 3UF7320-1AB00-0 1 1 unit 42J
• 110 ... 240 V AC/DC 3UF7320-1AU00-0 1 1 unit 42J
3UF7320-1AB00-0
1)
DM-F PROFIsafe fail-safe digital modules
For fail-safe disconnection using PROFIBUS/PROFIsafe or
PROFINET/PROFIsafe
Two relay enabling circuits, joint switching; two relay
outputs, common potential disconnected fail-safe; one
input for feedback circuit; three binary standard inputs
Rated control supply voltage Us:
• 24 V DC 3UF7330-1AB00-0 1 1 unit 42J
• 110 ... 240 V AC/DC 3UF7330-1AU00-0 1 1 unit 42J
3UF7330-1AB00-0
1)
Cannot be used in conjunction with SIMOCODE pro V for Modbus RTU or
EtherNet/IP communication.

10

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 10/17
© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
Accessories

■ Selection and ordering data


Version Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Connecting cables (essential accessory)


In different lengths for connecting basic unit, current
measuring module, current/voltage measuring module,
operator panel or expansion modules
Version Length
Flat 0.025 m 3UF7930-0AA00-0 1 1 unit 42J
0.1 m 3UF7931-0AA00-0 1 1 unit 42J
0.15 m 3UF7934-0AA00-0 1 1 unit 42J
3UF7932-0AA00-0 0.3 m 3UF7935-0AA00-0 1 1 unit 42J
0.5 m 3UF7932-0AA00-0 1 1 unit 42J
Round 0.5 m 3UF7932-0BA00-0 1 1 unit 42J
1.0 m 3UF7937-0BA00-0 1 1 unit 42J
2.5 m 3UF7933-0BA00-0 1 1 unit 42J
PC cables and adapters
USB PC cables 3UF7941-0AA00-0 1 1 unit 42J
For connecting to the USB interface of a PC/PG,
for communication with SIMOCODE pro through the system
interface
3UF7941-0AA00-0
USB/serial adapters 3UF7946-0AA00-0 1 1 unit 42J
For connecting an RS 232 PC cable to the USB interface of
a PC
Memory modules
Enable transmission to a new system, e.g. when a device
is replaced, without the need for additional aids or detailed
knowledge of the device.
Memory modules for SIMOCODE pro C 3UF7900-0AA01-0 1 1 unit 42J
3UF7901-0AA01-0 For saving the complete parameterization of
a SIMOCODE pro C system, titanium gray
Memory modules for SIMOCODE pro S and pro V 3UF7901-0AA01-0 1 1 unit 42J
For saving the complete parameterization of
a SIMOCODE pro system, titanium gray
Interface covers
For system interface, titanium gray 3RA6936-0B 1 5 units 42F
10

3RA6936-0B
Addressing plugs
For assigning the PROFIBUS or Modbus RTU address 3UF7910-0AA00-0 1 1 unit 42J
without using a PC/PG to SIMOCODE pro through the
system interface

3UF7910-0AA00-0

* You can order this quantity or a multiple thereof.


10/18 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
Accessories

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Accessories for motor control centers


With the draw-out technology often used in motor control
centers it is possible to integrate a SIMOCODE pro
initialization module in the switchboard on a permanent
basis. Feeder-related parameter and address data can
then be permanently assigned to this feeder.
Initialization modules 3UF7902-0AA00-0 1 1 unit 42J
3UF7902-0AA00-0 For automatic parameterization of SIMOCODE pro S and
SIMOCODE pro V basic units
Y connecting cables
For use in conjunction with the initialization module;
connects the basic unit, current measuring module or
current/voltage measuring module, and initialization
module
System interface length Open cable end
0.1 m 1.0 m 3UF7931-0CA00-0 1 1 unit 42J
0.5 m 1.0 m 3UF7932-0CA00-0 1 1 unit 42J
1.0 m 1.0 m 3UF7937-0CA00-0 1 1 unit 42J
Bus connection terminals
For shield support and strain relief of the PROFIBUS cable 3UF7960-0AA00-0 1 1 unit 42J
on a SIMOCODE pro S

3UF7960-0AA00-0
Door adapters
For external connection of the system interface from 3UF7920-0AA00-0 1 1 unit 42J
a control cabinet, for example

3UF7920-0AA00-0
Adapters for operator panel
The adapter enables the smaller 3UF7200 operator panel 3UF7922-0AA00-0 1 1 unit 42J

10
from SIMOCODE pro to be used in a front panel cutout in
which previously, e.g. after a change of system, a larger
3UF52 operator panel from SIMOCODE-DP had been
used, degree of protection IP54

3UF7922-0AA00-0
Labeling strips
• For pushbuttons of the 3UF720 operator panel 3UF7925-0AA00-0 100 400 units 42J
• For pushbuttons of the 3UF721 operator panel 3UF7925-0AA01-0 100 600 units 42J
with display
• For LEDs of the 3UF720 operator panel 3UF7925-0AA02-0 100 1200 units 42J

3UF7925-0AA02-0
Push-in lugs
For screw fixing, e.g. on mounting plate,
two units required per device
• Can be used for 3UF71.0, 3UF71.1 and 3UF71.2 3RV2928-0B 100 10 units 41E
• Can be used for 3UF700, 3UF701, 3UF73, 3UF74, 3UF75 3RP1903 1 10 units 41H
and 3UF77
• Can be used for 3UF7020, 3UF7600 3ZY1311-0AA00 1 10 units 41L
3RV2928-0B

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 10/19
© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7 motor management and control devices
Accessories

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Terminal covers
Covers for cable lug and busbar connections
• Length 100 mm, can be used for 3UF71.3-1BA0.-0 3RT1956-4EA1 1 1 unit 41B
• Length 120 mm, can be used for 3UF71.4-1BA0.-0 3RT1966-4EA1 1 1 unit 41B
Covers for box terminals
• Length 25 mm, can be used for 3UF71.3-1BA0.-0 3RT1956-4EA2 1 1 unit 41B
• Length 30 mm, can be used for 3UF71.4-1BA0.-0 3RT1966-4EA2 1 1 unit 41B
3RT1956-4EA1 Covers for screw terminals
Between contactor and current measuring module or
current/voltage measuring module for direct mounting
• Can be used for 3UF71.3-1BA0.-0 3RT1956-4EA3 1 1 unit 41B
3RT1956-4EA2 • Can be used for 3UF71.4-1BA0.-0 3RT1966-4EA3 1 1 unit 41B
Terminal parts kit
Can be used for current and/or current/voltage measuring
modules with DIN-rail connection, complete for one contactor
• M 8 x 25 3RT1955-4PA00 1 1 unit 41B
• M 10 x 30 3RT1966-4PA00 1 1 unit 41B
Box terminal blocks
For round and ribbon cables
• Up to 70 mm2, can be used for 3UF71.3-1BA0.-0 3RT1955-4G 1 1 unit 41B
• Up to 120 mm2, can be used for 3UF71.3-1BA0.-0 3RT1956-4G 1 1 unit 41B
• Up to 240 mm2, can be used for 3UF71.4-1BA0.-0 3RT1966-4G 1 1 unit 41B
3RT1956-4G
Bus termination modules
With separate control supply voltage for bus termination
following the last unit on the bus line
Supply voltage:
• 115/230 V AC 3UF1900-1KA00 1 1 unit 42J
• 24 V DC 3UF1900-1KB00 1 1 unit 42J

3UF1900-1KA00
Software
10

SIMOCODE ES (TIA Portal)


Software for configuring, commissioning, operating and
diagnosing SIMOCODE pro based on the TIA Portal,
see page 14/12.

3ZS1322...
SIMOCODE pro block library for SIMATIC PCS 7
The PCS 7 block library can be used for simple and easy
integration of SIMOCODE pro into the SIMATIC PCS 7
process control system, see page 14/15.

3ZS1632-1XE04-0YA0

* You can order this quantity or a multiple thereof.


10/20 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Monitoring and control devices


SIMOCODE 3UF motor management and control devices
3UF18 current transformers for overload protection
Basic units and accessories

■ Overview
The 3UF18 current transformers are protection transformers and
More information are used for actuating overload relays. Protection transformers
Homepage, see www.siemens.com/sirius are designed to ensure proportional current transfer up to
Industry Mall, see www.siemens.com/product?3UF18 a multiple of the primary rated current. The 3UF18 current
transformers convert the maximum current of the corresponding
operating range into the standard value of 1 A secondary.

■ Selection and ordering data


Type of mounting Operating range Screw terminals PU PS* PG
(UNIT,
Article No. Price SET, M)
A per PU
For mounting on contactors and stand-alone installation
Screw fixing 205 … 820 3UF1868-3GA00 1 1 unit 42J

3UF1868

■ Accessories
For contactor type Article No. Price PU PS* PG
per PU (UNIT,
SET, M)

Terminal covers
For transformer/contactor combinations and 3TX7696-0A 1 1 unit 41B
stand-alone installation for 3UF1868-3GA00 transformer
Note: One cover required per connection side.

10

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 10/21
© Siemens 2023

Monitoring and control devices

LOGO! logic modules

■ Overview
More information
Homepage, see www.siemens.com/LOGO
Industry Mall, see www.siemens.com/product?logo
LOGO!, see Catalog ST 70

• The compact, user-friendly, and low-cost solution for simple


control tasks
• Compact, user-friendly, can be used universally without
accessories
• All in one: The display and operator panel are integrated
• 36 different functions can be linked at a press of a button
or with PC software; up to 130 times in total
• LOGO! 8: 38/43 different functions can be linked at a press
of a button or with PC software; up to 200/400 times in total
• Functions can be changed simply with the press of a button.
No complicated rewiring
LOGO! logic modules
LOGO! basic modules with display LOGO! basic modules without display LOGO! expansion modules

The space-saving basic versions The cost-optimized basic versions Digital and analog inputs/outputs for
connection to LOGO!

LOGO! CMK2000 communications modules LOGO! CSM unmanaged LOGO! CMR (wireless communication)
10

For integration of LOGO! 8 in KNX For connecting to Industrial Ethernet in For configuring a low-cost remote
installations line, tree or star topologies signaling system

LOGO!Power LOGO!Contact switching modules LOGO! software

The flat power supply for distribution For switching resistive loads and motors The user-friendly software for switching
boards directly program generation

■ Application
The LOGO! logic module is the user-friendly, low-cost solution • Special controls for conservatories and greenhouses
for simple control tasks. • Signal preprocessing for other controllers
LOGO! is universally applicable, e.g.: LOGO! Modular logic modules can be expanded easily for each
• Building installation and wiring (lighting, shutters, awnings, application.
doors, access control, barriers, ventilation systems, etc.)
Marine approvals:
• Control cabinet installation American Bureau of Shipping, Bureau Veritas, Det Norske
• Machine and device construction (pumps, small presses, Veritas, Germanischer Lloyd, Lloyd's Register of Shipping,
compressors, hydraulic lifts, conveyors, etc.) Polski Rejestr Statków, etc.

10/22 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
General data

■ Overview
The SIRIUS 3RA28 function modules enable the assembly
of starters and contactor assemblies for direct-on-line and
star-delta (wye-delta) starting. They include the key control
functions required for the particular feeder, e.g. timing and
electrical interlocking. The function modules that function as
timing relays are mounted quickly and simply on SIRIUS
contactors – without any great wiring effort.
The SIRIUS 3RA28 solid-state time-delay auxiliary switches
which can be mounted on contactors are designed for contactor
coil voltages in the range from 24 to 240 V AC/DC (wide voltage
range). Auxiliary switches for control and alarm signals are used
specially for switching the smallest signals for electronics
applications. They are used, for example, for allowing a pump
or fan to run on, or for the delayed activation of a gate drive.
Simply by being plugged in place, the SIRIUS 3RT19 timing
relays enable different functionalities required for the assembly
of starters to be realized in the feeder. At the same time the
timing relays for mounting on contactors reduce the wiring work
7PV15, SIRIUS 3RP25 and SIRIUS 3RP20 timing relays required within the feeder and save space in the control cabinet.

More information
Device series
Homepage, see www.siemens.com/sirius-timing-relays SIRIUS timing relays for DIN-rail mounting
Industry Mall, see www.siemens.com/product?3RP • SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm,
see page 10/24
Electronic timing relays are used in control, starting, and protective • SIRIUS 3RP20 timing relays, 45 mm, see page 10/36
circuits for all switching operations involving time delays.
• 7PV15 timing relays, 17.5 mm, see page 10/42
Their fully developed concept and space-saving, compact
design make the SIRIUS 3RP timing relays ideal timer modules SIRIUS timing relays for mounting on contactors
for control cabinet, switchgear and control manufacturers in • SIRIUS 3RA28 solid-state time-delay auxiliary switches for
the industry. mounting on 3RT2 contactors and 3RH2 contactor relays,
see page 3/95
With their narrow design, the 7PV15 timing relays are ideal in
particular for use in heating, ventilation and air-conditioning • SIRIUS 3RA28 function modules for mounting on 3RT2
systems and in compressors. All 7PV15 timing relays in this contactors and 3RH2 contactor relays, see page 3/100
enclosure version are suitable for snap-on mounting on • SIRIUS 3RT19 solid-state time-delay auxiliary switches for
TH 35 DIN rails according to IEC 60175. The enclosure complies mounting on 3RT1 contactors, see page 3/96
with DIN 43880.

■ Benefits

10
• The right design for every application • Versions with logical separation
• Clear-cut basic range with five basic units in the case of the • Low variance: One design for distribution boards and for
7PV15 timing relays, and up to seven basic units in the case control cabinets
of the 3RP timing relays • Compliance with EMC requirements for buildings
• Considerable logistical advantages thanks to versions with • Environmentally friendly laser inscription instead of printing
wide voltage and wide time setting range containing solvents
• No tools required for assembly or disassembly on DIN rails • Versions as snap-on modules for reducing wiring and saving
• Cadmium-free relay contacts space in the control cabinet
• Recyclable, halogen-free enclosure • Versions with coated printed circuit board
• Optimum price/performance ratio • Versions with screw terminals or alternatively with spring-
loaded terminals

■ Application
Timing relays with ON-delay Star-delta (wye-delta) timing relays
• Interference pulse suppression (gating of interference pulses) • Switching over motors from wye to delta with a dead interval
• Gradual startup of motors so as not to overload the power of 50 ms to prevent phase-to-phase short circuits
supply Multifunctional timing relays
Timing relays with OFF-delay • Maximum flexibility, with a device for every application
• Generation of overtravel functions following removal of voltage • Available with relay and semiconductor output
• Gradual, delayed shutdown, e.g. of motors or fans, to allow • Versions for railway applications for more exacting
a plant to be shut down selectively requirements (e.g. temperature range, vibration/shock
resistance and EMC)
Clock-pulse relay
• Flashing, asymmetrical Watchdog function
• Monitoring of cyclic events

Siemens IC 10 · 2023 10/23


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm

■ Overview
More information
Homepage, see www.siemens.com/sirius-timing-relays
Industry Mall, see www.siemens.com/product?3RP25
LED for indicating TIA Selection Tool Cloud (TST Cloud), see
"Timing relay
connected to voltage" Cover caps inscribed www.siemens.com/tstcloud/?node=SIRIUSRelais
on inside Conversion tool, see www.siemens.com/conversion-tool
LED for indicating Simulator, see
"Relay switched"
IC01_00291a
https://support.industry.siemens.com/cs/ww/en/view/103556391
Operating time
adjustment switch
Time setting range
selector switch Data matrix code
Function selector
switch

Video: What are the benefits of SIRIUS 3RP25 timing relays?

Electronic timing relays for general use in control systems and


SIRIUS 3RP25 timing relay mechanical engineering with:
• 1 or 2 CO, 1 NO (semiconductor) or 3 NO
• Monofunction or multifunction
• Combination voltage or wide voltage range
• Single or selectable time setting ranges
• Switch position indication and voltage indication by LED
• Versions with coated printed circuit board
Article number scheme
Product versions Article number
Timing relays 3RP25 @ @ – @ @ @ @ 0 – @ @ @ @
Product function/ Multifunction 0 5 7 time ranges 0.05 s ... 100 h
time setting ranges ON-delay 1 1 1 time range 0.5 ... 10 s
1 2 1 time range 1 ... 3 s
1 3 1 time range 5 ... 100 s
2 5 7 time ranges 0.05 s ... 100 h
2 7 4 time ranges 0.05 s ... 240 s
OFF-delay with control signal 3 5 7 time ranges 0.05 s ... 100 h
10

OFF-delay without control signal, 4 0 7 time ranges 0.05 s ... 600 s


non-volatile, passing make contact
Clock-pulse relay, flashing, asymmetrical 5 5 7 time ranges 0.05 s ... 100 h
Star-delta (wye-delta) function with 6 0 Star-delta (wye-delta) 1 ... 20 s,
coasting function (idling) coasting time (idling) 600 s
Star-delta (wye-delta) function 7 4 1 time range 1 ... 20 s
7 6 1 time range 3 ... 60 s
Connection type Screw terminals 1
Spring-loaded terminals (push-in) 2
Contacts 1 CO A
2 CO B
Semiconductors (transistor NPN) C
Semiconductors (thyristor), two-wire E
1 NO + 1 NO (SD) N
2 CO force-guided R
3 NO S
Control supply voltage 24 V AC/DC B 3
200 … 240 V/380 … 440 V AC M2
400 ... 440 V AC T 2
12 ... 240 V AC/DC or W3
24 ... 240 V AC/DC (3RP2505-.RW30)
Special versions With coated printed circuit board 0 A X 0
Example 3RP25 0 5 – 1 A B 3 0
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

10/24 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm
3RP2505 multifunctional timing relays
With a set of foil labels the timing relay can be legibly marked
Two setting options for implementing the
with the functions which can be selected on the timing relay.
multifunctions (A-M):
This is supplied together with the multifunctional timing relay.
1 Determination of 13 functions by the
IC01_00353b

setting A to M, The same potential must be applied to terminals A. and B.


with 1 CO, 1 NO, 2 CO that switch in Note:
parallel.
2 Extended function variance by selecting
The activation of loads parallel to the start input is permissible
the time range and determining, when using AC/DC control voltage.
whether 2 CO switch in parallel or
whether 1 CO switches with delay + 1 CO L1
switches immediately (1 CO + 1 CO)

2 S1

1
A1 B1
K2 K1
A2
Setting the functions on the device N
IC01_00297
The functions of the 3RP2505 multifunctional timing relays can
be set by means of the function selector switch. Whether both
Diagram
CO contacts are switched in parallel or one CO contact with
a delay and one instantaneously and the choice of time setting
range are set by means of the time setting range selector switch.
The exact operating time can be adjusted with the operating
time switch.
Overview of functions
Identifica- 13 functions 27 functions
tion letter
1 CO contact (1 CO), 1 NO contact (1 NO) semiconductor, 13 functions (A - M) 2 CO contacts switched in parallel (2 CO) +
2 CO contacts switched in parallel (2 CO) or 13 functions (A - M) 1 delayed CO contact + 1 instantaneous CO contact
2 CO contacts force-guided and switched in parallel with delay (1 CO + 1 CO) and star-delta (wye-delta) function
(2 CO)
A ON-delay ON-delay and instantaneous contact

B OFF-delay with control signal OFF-delay with control signal and instantaneous contact

C ON-delay/OFF-delay with control signal ON-delay/OFF-delay with control signal and instantaneous contact

10
D Flashing, symmetrical, starting with interval Flashing, symmetrical, starting with interval and instantaneous contact

E Passing make contact, interval relay Passing make contact, interval relay and instantaneous contact

F Retriggerable interval relay with deactivated control signal Retriggerable interval relay with deactivated control signal
(passing break contact with control signal) (passing break contact with control signal) and instantaneous contact
G Passing make contact, with control signal, not retriggerable Passing make contact, with control signal, not retriggerable,
(pulse-forming with control signal) (pulse-forming with control signal) and instantaneous contact
H Additive ON-delay, instantaneous OFF Additive ON-delay, instantaneous OFF with control signal
with control signal and instantaneous contact
I Additive ON-delay with control signal Additive ON-delay with control signal and instantaneous contact

J Flashing, symmetrical, starting with pulse Flashing, symmetrical, starting with pulse and instantaneous contact

K Pulse-delayed (fixed pulse (at 1 s) and Pulse-delayed (fixed pulse (at 1 s)


settable pulse delay) and settable pulse delay) and instantaneous contact
L Pulse-delayed with control signal (fixed pulse (at 1 s) and Pulse-delayed with control signal (fixed pulse (at 1 s)
settable pulse delay) and settable pulse delay) and instantaneous contact
M Retriggerable interval relay with activated control signal Retriggerable interval relay with activated control signal
(watchdog) and instantaneous contact (watchdog)
-- -- Star-delta (wye-delta) function

Siemens IC 10 · 2023 10/25


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm
Simulator
The 3RP25 simulator visualizes different time functions in the
3RP25 timing relay. Any fault scenario can be simulated.
The tool is available free of charge, see
https://support.industry.siemens.com/cs/ww/en/view/103556391.

3RP25 simulator

■ Benefits
• Easy stock keeping and logistics thanks to low variance of Standards and approvals
devices • IEC 60721-3-3 "Classification of environmental conditions"
• Reduced space requirement in the control cabinet thanks to • IEC 61812-1/DIN VDE 0435 Part 2021 "Specified time relays
variants in width 17.5 mm and 22 mm for industrial use"
• Consistent for all functions thanks to wide voltage range from • IEC 61000-6-2, IEC 61000-6-3 and IEC 61000-6-4
12 to 240 V AC/DC "Electromagnetic compatibility"
• Up to 27 functions according to IEC 61812 in the • IEC 60947-5-1 "Low-voltage switchgear and controlgear –
multifunctional timing relay with wide voltage range Electromechanical control circuit devices"
• Multifunctional timing relay with semiconductor output for high
switching frequencies, bounce-free and wear-free switching

■ Application
Timing relays are used in control, starting, and protective circuits to IPC-610. Suitable for applications in rail, agriculture, mining,
for all switching operations involving time delays. They woodworking, etc.
10

guarantee a high level of functionality and a high repeat


accuracy of timer settings. Enclosure version

Use in environments exposed to dust, condensation, rapid All timing relays are suitable for snap-on mounting on TH 35 DIN
temperature changes and corrosion is possible thanks to rails according to IEC 60715 or for screw fixing.
the standard coating of the printed circuit board according

■ Technical specifications
More information
Technical specifications, see Internal circuit diagrams, see CAx Download Manager
https://support.industry.siemens.com/cs/ww/en/ps/16354/td https://support.industry.siemens.com/my/ww/en/CAxOnline#CAxOnline
Equipment Manual, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16354/faq
https://support.industry.siemens.com/cs/ww/en/view/103532830

Article number 3RP2505-.A, 3RP2505-.C, 3RP2505-.B, 3RP2505-.R,


3RP251., 3RP2525-.B,
3RP2525-.A, 3RP2527, 3RP254., 3RP256., 3RP257.
3RP253., 3RP255.
Dimensions (W x H x D) 17.5 x 100 x 90 22.5 x 100 x 90
H

10/26 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm

Article number 3RP25..-.AB30, 3RP25..-.BT20, 3RP25..-.CW30 3RP25..-.EW30


3RP25..-.AW30, 3RP25..-.NM20
3RP25..-.AW30-0AX0,
3RP25..-.BB30,
3RP25..-.BW30,
3RP25..-.BW30-0AX0,
3RP25..-.NW30,
3RP25..-.RW30,
3RP25..-2RW30-0AX0,
3RP25..-.SW30
General technical specifications
Insulation voltage for overvoltage V 300 500 300 --
category III according to IEC 60664
for pollution degree 3, rated value
Ambient temperature
• During operation °C -25 ... +60
• During storage °C -40 ... +85
Switching capacity current A 0.01 ... 3 0.01 ... 3 0.01 ... 1 0.01 ... 0.6
with inductive load
Operational current of the auxiliary
contacts
• At AC-15
- At 24 V A 3 3 1 --
- At 250 V A 3 3 1 --
- At 400 V A -- 3 -- --
• At DC-12
- At 24 V A -- -- 1 --
- At 125 V A -- -- 1 --
- At 250 V A -- -- 1 --
• At DC-13
- At 24 V A 1 1 -- --
- At 125 V A 0.2 0.2 -- --
- At 250 V A 0.1 0.1 -- --
Thermal current A 5 5 1 0.6
Mechanical endurance 10 000 000
(operating cycles)
Electrical endurance 100 000 300 000 100 000
(operating cycles) for AC-15 at
230 V typical

Article number 3RP25..-.AB30, 3RP2505-.BT20, 3RP2505-.AW30, 3RP2505-.RW30,


3RP2535-.AW30, 3RP257.-.NM20 3RP2505-.AW30-0AX0, 3RP2505-.RW30-0AX0
3RP2540-.AW30, 3RP251.-.AW30,
3RP25..-.BB30, 3RP2525-.AW30,
3RP2540-.BW30 3RP2555-.AW30,
3RP2505-.BW30,

10
3RP2525-.BW30,
3RP2505-.BW30-0AX0,
3RP2505-.CW30,
3RP2527-.EW30,
3RP257.-.NW30,
3RP2560-.SW30
General technical specifications
Operating range factor of the
control supply voltage, rated value
• At AC
- At 50 Hz 0.85 ... 1.1 0.85 ... 1.1 0.8 ... 1.1 0.7 ... 1.1
- At 60 Hz 0.85 ... 1.1 0.85 ... 1.1 0.8 ... 1.1 0.7 ... 1.1
• At DC 0.85 ... 1.1 -- 0.8 ... 1.1 0.7 ... 1.1

Article number 3RP25..-1...0 3RP25..-2...0


Type of electrical connection for Screw terminals Spring-loaded terminals (push-in)
auxiliary and control circuits
Design of thread M3 --
of connection screw
Tightening torque Nm 0.6 … 0.8 --
Type of connectable conductor
cross-sections
• Solid 1 x (0.5 ... 4 mm²), 2 x (0.5 ... 2.5 mm²) 1 x (0.5 ... 4 mm²)
• Finely stranded with end sleeve 1 x (0.5 ... 4 mm²), 2 x (0.5 ... 1.5 mm²) 1 x (0.5 ... 2.5 mm²)
• For AWG cables
- Solid 1 x (20 ... 12), 2 x (20 ... 14) 1 x (20 ... 12)
- Stranded 1 x (20 ... 12), 2 x (20 ... 14) 1 x (20 ... 12)

Siemens IC 10 · 2023 10/27


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm
3RP25 function diagrams
Multifunction 3RP2505-.A, 1 CO, 13 functions and 3RP2505-.C, 1 NO (semiconductor), 13 functions

A1/A2 A1/A2
> 35 ms A1/A2

IC01_00344
IC01_00341d
A1/A2

IC01_00343
B1/A2

IC01_00342
B1/A2
15/18 15/18
15/18 15/16
15/16 15/18 15/16
t 15/16 t t
t t t

A B C D
ON-delay OFF-delay with control signal ON-delay/OFF-delay with Flashing, symmetrical, starting with
control signal interval

A1/A2 A1/A2 A1/A2


> 35ms > 35ms t1 t2 t3
IC01_00345

A1/A2
B1/A2 IC01_00346

IC01_00412
B1/A2

IC01_00347
B1/A2
15/18
15/16 15/18 15/18 15/18
t 15/16 15/16 15/16
t t t

E F G H
Passing make contact, interval relay Retriggerable interval relay with Passing make contact with Additive ON-delay, instantaneous OFF
deactivated control signal (passing control signal, not retriggerable with control signal
break contact with control signal) (pulse-forming with control signal)

A1/A2 IC01_00561 A1/A2


t1 t2 t3 A1/A2
IC01_00349a

A1/A2
1s B1/A2

IC01_00350c
IC01_00348a

B1/A2
15/18 15/18 1s
15/18 15/16 15/16 15/18
15/16 t t t 15/16
t t

I J K L
10

Additive ON-delay with control signal Flashing, symmetrical, starting with Pulse-delayed (fixed pulse (at 1 s) Pulse-delayed with control signal (fixed
pulse and settable pulse delay) pulse (at 1 s) and settable pulse delay)

A1/A2
IC01_00351

B1/A2
15/18
15/16
t <t t

M
Retriggerable interval relay with
activated control signal (watchdog)

Legend
A ... M Identification letters
Timing relay energized
Contact closed
Contact open

10/28 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm
Multifunction 3RP2505-.R, 13 functions, 2 CO force-guided and switched in parallel with delay

A1/A2 A1/A2
> 35 ms A1/A2
A1/A2
B1/A2
B1/A2 15/18
15/18 15/16

NSB0_00871d
15/18

IC01_00313
NSB0_00876
15/16 15/18
15/16
15/16 t t

IC01_00310
25/28
25/28 t 25/28 25/26
25/26 25/28 25/26
t t
t 25/26 t t
t

A B C D
ON-delay OFF-delay with control signal ON-delay/OFF-delay with Flashing, symmetrical, starting with
control signal interval

A1/A2 A1/A2 A1/A2


A1/A2 > 35ms > 35ms t1 t2 t3
B1/A2 B1/A2 B1/A2
15/18
NSB0_00880

15/16 15/18 15/18 15/18


NSB0_00882

NSB0_00884

IC01_00411
15/16 15/16 15/16
25/28
25/26 25/28 25/28 25/28
t 25/26 25/26 25/26
t t t

E F G H
Passing make contact, interval relay Retriggerable interval relay with Passing make contact with Additive ON-delay, instantaneous OFF
deactivated control signal (passing control signal, not retriggerable with control signal
break contact with control signal) (pulse-forming with control signal)

A1/A2
A1/A2 A1/A2
t1 t2 t3 A1/A2 1s B1/A2
B1/A2 15/18 1s
15/18
15/16 IC01_00562 15/18
IC01_00476

15/16
15/18 15/16

IC01_00321c
1s
IC01_00307b

15/16 25/28 25/28 t 1s


25/26 25/26 25/28
25/28 25/26
25/26 t t t
t t

I J K L
Additive ON-delay with control signal Flashing, symmetrical, starting with Pulse-delayed (fixed pulse at 1 s and Pulse-delayed with control signal (fixed

10
pulse settable pulse delay) pulse at 1 s and settable pulse delay)

A1/A2
B1/A2
15/18
15/16
IC01_00323

t <t t
25/28
25/26
t <t t

M
Retriggerable interval relay with
activated control signal (watchdog)

Legend
A ... M Identification letters
Timing relay energized
Contact closed
Contact open

Siemens IC 10 · 2023 10/29


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm
Multifunction 3RP2505-.B, 27 functions, 2 CO
A B
2 CO switched in parallel 1 delayed CO contact + 2 CO switched in parallel 1 delayed CO contact +
1 instantaneous CO contact 1 instantaneous CO contact

A1/A2
> 35 ms A1/A2
A1/A2 A1/A2 > 35ms
B1/A2
15/18 B1/A2
15/18
NSB0_00871d

15/16 15/16 15/18


15/16 15/18

IC01_00309

IC01_00310
25/28 t t 15/16

IC01_00311
25/26 21/24 25/28 t
t 21/22 25/26 21/24
t 21/22

ON-delay ON-delay and instantaneous contact OFF-delay with control signal OFF-delay with control signal and
instantaneous contact

C D
2 CO switched in parallel 1 delayed CO contact + 2 CO switched in parallel 1 delayed CO contact +
1 instantaneous CO contact 1 instantaneous CO contact

A1/A2 A1/A2 A1/A2


A1/A2
B1/A2 B1/A2 15/18
15/16 15/18
15/18

IC01_00313
15/18 15/16
NSB0_00876

IC01_00314
15/16 15/16 t t
t t
IC01_00312

25/28
25/28 t t 25/26 21/24
25/26 21/24 21/22
21/22 t t
t t

ON-delay/OFF-delay with ON-delay/OFF-delay with control Flashing, symmetrical, starting with Flashing, symmetrical, starting with
control signal signal and instantaneous contact interval interval and instantaneous contact

E F
2 CO switched in parallel 1 delayed CO contact + 2 CO switched in parallel 1 delayed CO contact +
1 instantaneous CO contact 1 instantaneous CO contact

A1/A2
> 35ms A1/A2
A1/A2 A1/A2 >35ms
B1/A2
15/18 B1/A2
15/18
NSB0_00880

15/16 15/16 15/18


NSB0_00882

15/18
IC01_00315

15/16
25/28 t 15/16

IC01_00316
10

25/26 21/24 25/28 t


t 21/22 25/26 21/24
t 21/22

Passing make contact, interval relay Passing make contact, interval relay Retriggerable interval relay with Retriggerable interval relay with
and instantaneous contact deactivated control signal (passing deactivated control signal (passing
break contact with control signal) break contact with control signal) and
instantaneous contact

G H
2 CO switched in parallel 1 delayed CO contact + 2 CO switched in parallel 1 delayed CO contact +
1 instantaneous CO contact 1 instantaneous CO contact

A1/A2 A1/A2
A1/A2 t1 t3 A1/A2
> 35ms >35ms t2 t1 t3
t2
B1/A2 B1/A2
B1/A2 B1/A2
15/18 15/18
15/18 15/18
NSB0_00884

IC01_00411

15/16 15/16
15/16 15/16
IC01_00317

IC01_00318

25/28 t 25/28 t
25/26 21/24 25/26 21/24
t 21/22 t 21/22

Passing make contact with Passing make contact with Additive ON-delay, instantaneous Additive ON-delay, instantaneous OFF
control signal, not retriggerable control signal, not retriggerable OFF with control signal with control signal and instantaneous
(pulse-forming with control signal) (pulse-forming with control signal) contact
and instantaneous contact

Legend
A ... H Identification letters
Timing relay energized
Contact closed
Contact open

10/30 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm
Multifunction 3RP2505-.B, 27 functions, 2 CO (continued)
I J
2 CO switched in parallel 1 delayed CO contact + 2 CO switched in parallel 1 delayed CO contact +
1 instantaneous CO contact 1 instantaneous CO contact

A1/A2 A1/A2
t1 t2 t3 t1 t3 A1/A2
t2 A1/A2
B1/A2 B1/A2 15/18
15/18

IC01_00476
15/16
15/18 15/18 15/16
IC01_00307b

IC01_00319
15/16 15/16 25/28 t t

IC01_00306
25/28 t 25/26 21/24
25/26 21/24 t t 21/22
t 21/22

Additive ON-delay with control signal Additive ON-delay with control signal Flashing, symmetrical, starting with Flashing, symmetrical, starting with
and instantaneous contact pulse pulse and instantaneous contact

K L
2 CO switched in parallel 1 delayed CO contact + 2 CO switched in parallel 1 delayed CO contact +
1 instantaneous CO contact 1 instantaneous CO contact

A1/A2
A1/A2
A1/A2 A1/A2
B1/A2
1s B1/A2
1s
15/18 15/18 1s
NSB0_00871d

15/16 15/16 15/18


15/18
IC01_00320b

15/16

IC01_00321c
t 15/16

IC01_00322b
25/28 t 1s
25/26 21/24 25/28 t
21/22 25/26 21/24
t 21/22
t

Pulse-delayed (fixed pulse at 1 s and Pulse-delayed (fixed pulse at 1 s and Pulse-delayed with control signal Pulse-delayed with control signal (fixed
settable pulse delay) settable pulse delay) and (fixed pulse at 1 s and settable pulse pulse at 1 s and settable pulse delay)
instantaneous contact delay) and instantaneous contact

M *
2 CO switched in parallel 1 delayed CO contact + 2 CO contacts switched in parallel or
1 instantaneous CO contact 1 delayed CO contact +
1 instantaneous CO contact

A1/A2
A1/A2
B1/A2 A1/A2
B1/A2
IC01_00325

15/18 15/18

10
15/16 15/18
IC01_00323

15/16 25/28
IC01_00324

t <t t
25/28 t <t t t 50ms
25/26 21/24
21/22
t <t t

Retriggerable interval relay with Retriggerable interval relay with Star-delta (wye-delta) function
activated control signal (watchdog) activated control signal and
instantaneous contact (watchdog)

Legend
I ... M Identification letters
Timing relay energized
Contact closed
Contact open

Siemens IC 10 · 2023 10/31


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm
Monofunctions 3RP251. to 3RP257.1)

A1/A2 A1/A2

NSB0_00869a
NSB0_00858
A1/A2 >35 ms
15/18

NSB0_00871d

NSB0_00859
15/16 A1/A2 B1/A2
15/18
15/16 t 15/18
25/28
t 25/26 15/16
t t

3RP251.-.AW30, 1 CO, ON-delay 3RP2525-..W30, 2 CO, ON-delay 3RP2527-.EW30, 1 NO 3RP2535-.AW30, 1 CO, OFF-delay with
(semiconductor), ON-delay control signal

250 ms 250 ms
> 250ms 250 ms A1/A2 A1/A2

IC01_00327
A1/A2 A1/A2
IC01_00354

15/18 15/18
15/16 15/16

IC01_00355
IC01_00326
15/18 15/18
15/16 15/16 t t
25/28 25/28
t t 25/26 25/26
t t

3RP2540-.A.30, 1 CO, OFF-delay 3RP2540-.A.30, 1 CO, positive 3RP2540-.B.30, 2 CO, OFF-delay 3RP2540-.B.30, 2 CO, positive passing
(N)1) passing make contact (O)1) (N)1) make contact (O)1)

A1/A2
A./A2 A1/A2
NSB0_00863

A1/A2

IC01_00330a
B1/A2

IC01_00407b
15/18 17/18 17/18
17/18
15/16
IC01_00328a

50 ms 17/28 17/28
17/28 t
t 50 ms 50 ms
Dead time Pulse time t t Idling
17/38

3RP2555-.AW30, 1 CO, flashing, 3RP2560-.SW30, 3 NO, star-delta 3RP257.-.NM20, 2 NO, star-delta 3RP257.-.NW30, 2 NO, star-delta
asymmetrical, starting with interval (wye-delta) function with overtravel (wye-delta) function (wye-delta) function
(clock-pulse relay) function (idling)

Legend
Timing relay energized
10

Contact closed
Contact open
1) 3RP2540 has a double function:
Function N = OFF-delay
Function O = Positive passing make contact.

10/32 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm
Possibilities of operation of the 3RP2560-.SW30 timing relay
Operation 1: Start contact B./A2 is open when control supply Operation 4: Start contact B./A2 opens while delta time is
voltage A./A2 is applied running and is applied again
The control supply voltage is applied to A./A2 and there is no If the control signal on B./A2 is applied and switched off again
control signal on B./A2. This starts the * timing. The idling time during the delta time, although the idling time has not yet
(coasting time) is started by applying a control signal to B./A2. elapsed, the idling time (coasting time) is reset to zero. If the
When the set time tIdling (30 to 600 s) has elapsed, the output control signal is re-applied to B./A2, the idling time is restarted.
relays (17/38 and 17/28) are reset. If the control signal on B./A2
is switched off (minimum OFF period 270 ms), a new timing
is started. A./A2

Note: B./A2
Observe response time (dead time) of 400 ms on energizing
17/18
control supply voltage until contacts 17/18 and 17/38 close. Y

NSB0_00894f
17/28
A./A2
17/38
B./A2
tY 50 ms tIdling tIdling tIdling
17/18
Y Operation 4
NSB0_00891d

17/28 Legend
17/38 Timing relay energized
Contact closed
tY 50 ms tIdling tIdling50 ms tIdling 300 ms
Contact open
tY = Star time 1 to 20 s
Operation 1
tIdling = Idling time (coasting time) 30 to 600 s
Operation 2: Start contact B./A2 is closed when control supply
voltage A./A2 is applied.
Note:
If the control signal B./A2 is already present when the control
supply voltage A./A2 is applied, no timing is started. The timing The following applies to all operations: The pressure switch
is only started when the control signal B./A2 is switched off. controls the timing via B./A2.

A./A2 Application example based on standard operation (operation 1):


For example, use of 3RP2560 for compressor control
B./A2
Frequent starting of compressors strains the network, the
machine, and the increased costs for the operator. The new
17/18
timing relay prevents frequent starting at times when there is

10
Y
high demand for compressed air. A special control circuit
NSB0_00892d

17/28
prevents the compressor from being switched off immediately
17/38
when the required air pressure in the tank has been reached.
Instead, the valve in the intake tube is closed and the
compressor runs in "Idling" mode, i.e. in no-load operation for
tY tIdling
50 ms a specific time which can be set from 30 to 600 s.
Operation 2 If the pressure falls within this time, the motor does not have to
be restarted again, but can return to rated load operation from
Operation 3: Start contact B./A2 closes while star time is running
no-load operation.
If the control signal B./A2 is applied again during the star time,
If the pressure does not fall within this idling time, the motor is
the idling time starts and the timing is terminated normally.
switched off.
The pressure switch controls the timing via B./A2.
A./A2
The control supply voltage is applied to A./A2 and the start
B./A2 contact B./A2 is open, i.e. there is no control signal on B./A2
when the control supply voltage is applied. The pressure switch
17/18 signals "too little pressure in system" and starts the timing by way
Y of terminal B./A2. The compressor is started, enters * operation,
and fills the pressure tank.
NSB0_00893d

17/28
When the pressure switch signals "sufficient pressure", the
17/38
control signal B./A2 is applied, the idling time (coasting time)
is started, and the compressor enters no-load operation for the
tY 50 ms
set period of time from 30 to 600 s. The compressor is then
tIdling switched off. The compressor is only restarted if the pressure
switch responds again (low pressure).
Operation 3

Siemens IC 10 · 2023 10/33


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm

■ Selection and ordering data


Multi-unit
packaging,
see
page 16/7.

3RP2505-2AB30 3RP2505-2BB30 3RP2525-2AW30 3RP2540-2AW30 3RP2555-2AW30 3RP2576-2NW30

Number of Number of CO Semi- Adjustable Control supply voltage Stan- Article No. Price PU PS* PG
NO contacts contacts con- time dard per PU (UNIT,
ductor coating SET, M)
Instan- De- Instan- De- output at at DC IPC-610
tane- layed tane- layed 50/60
ous switch- ous switch- Hz AC
switch- ing switch- ing
ing ing
V V
13 functions
0 0 0 1 No 0.05 s ... 100 h 24 24 No 3RP2505-@AB30 1 1 unit 41H
12 ... 240 12 ... 240 No 3RP2505-@AW30 1 1 unit 41H
Yes 3RP2505-2AW30-0AX0 1 1 unit 41H
0 1 0 0 Yes 0.05 s ... 100 h 12 ... 240 12 ... 240 No 3RP2505-@CW30 1 1 unit 41H
13 functions, suitable for railway applications
0 0 0 21) No 0.05 s ... 100 h 24 ... 240 24 ... 240 No 3RP2505-@RW30 1 1 unit 41H
Yes 3RP2505-2RW30-0AX0 1 1 unit 41H
27 functions
0 0 0 22) No 0.05 s ... 100 h 24 24 No 3RP2505-@BB30 1 1 unit 41H
400 ... 440 -- No 3RP2505-@BT20 1 1 unit 41H
12 ... 240 12 ... 240 No 3RP2505-@BW30 1 1 unit 41H
Yes 3RP2505-2BW30-0AX0 1 1 unit 41H
ON-delay
0 0 0 1 No 0.5 ... 10 s 12 ... 240 12 ... 240 No 3RP2511-@AW30 1 1 unit 41H
1 ... 30 s 12 ... 240 12 ... 240 No 3RP2512-@AW30 1 1 unit 41H
5 … 100 s 12 ... 240 12 ... 240 No 3RP2513-@AW30 1 1 unit 41H
0.05 s ... 100 h 12 ... 240 12 ... 240 No 3RP2525-@AW30 1 1 unit 41H
0 0 0 2 No 0.05 s ... 100 h 24 24 No 3RP2525-@BB30 1 1 unit 41H
12 ... 240 12 ... 240 No 3RP2525-@BW30 1 1 unit 41H
0 1 0 0 Yes 0.05 s ... 240 s 12 ... 240 12 ... 240 No 3RP2527-@EW30 1 1 unit 41H
10

OFF-delay with control signal


0 0 0 1 No 0.05 s ... 100 h 12 ... 240 12 ... 240 No 3RP2535-@AW30 1 1 unit 41H
OFF-delay without control signal, non-volatile,
passing make contact
0 0 0 14) No 0.05 s ... 600 s 24 24 No 3RP2540-@AB30 1 1 unit 41H
12 ... 240 12 ... 240 No 3RP2540-@AW30 1 1 unit 41H
0 0 0 24) No 0.05 s ... 600 s 24 24 No 3RP2540-@BB30 1 1 unit 41H
12 ... 240 12 ... 240 No 3RP2540-@BW30 1 1 unit 41H
Clock-pulse relay, flashing, asymmetrical
0 0 0 1 No 0.05 s ... 100 h 12 ... 240 12 ... 240 No 3RP2555-@AW30 1 1 unit 41H
Star-delta (wye-delta) function with coasting function (idling)
1 2 0 0 No 1 ... 20 s 12 ... 240 12 ... 240 No 3RP2560-@SW30 1 1 unit 41H
Star-delta (wye-delta) function
1 1 0 0 No 1 ... 20 s 380 ... 4403) -- No 3RP2574-@NM20 1 1 unit 41H
12 ... 240 12 ... 240 No 3RP2574-@NW30 1 1 unit 41H
1 1 0 0 No 3 ... 60 s 380 ... 4403) -- No 3RP2576-@NM20 1 1 unit 41H
12 ... 240 12 ... 240 No 3RP2576-@NW30 1 1 unit 41H
Type of electrical connection
• Screw terminals 1
• Spring-loaded terminals (push-in) 2
1) Force-guided contacts. Notes:
2) Optionally 1 CO delayed + 1 CO instantaneous.
3)
Accessories, see page 10/35.
With 3RP2574-.NM20 and 3RP2576-.NM20, connection of 200 to 240 V AC,
50/60 Hz control voltage is also possible. In the case of 3RP2505, the functions can be adjusted by means
4) Setting of output contacts in as-supplied state not defined (bistable relay). of function selector switches on the device. With a set of foil
Application of the control supply voltage once results in contact labels the timing relay can be legibly marked with the functions
changeover to the correct setting. which can be selected on the timing relay. This is included in the
scope of supply. The same potential must be applied to
terminals A. and B.
For functions, see the overview of functions on page 10/25.

* You can order this quantity or a multiple thereof.


10/34 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP25 timing relays, 17.5 mm and 22.5 mm

■ Accessories
More information
You can find information on configuring and dimensioning the accessories
in the Equipment Manual, see
https://support.industry.siemens.com/cs/ww/en/view/103532830

Version Article No. Price PU PS* PG


per PU (UNIT,
SET, M)

Terminals for SIRIUS devices in the industrial DIN-rail enclosure


Removable terminals Screw terminals

• 2-pole, up to 1 x 4 mm² or 2 x 2.5 mm² 3ZY1122-1BA00 1 6 units 41L

3ZY1122-1BA00
Spring-loaded
terminals (push-in)
• 2-pole, up to 1 x 4 mm² or 2 x 1.5 mm² 3ZY1122-2BA00 1 6 units 41L
(in shared end sleeve)

3ZY1122-2BA00
Accessories for enclosures
Sealing covers
• 17.5 mm 3ZY1321-1AA00 1 5 units 41L
• 22.5 mm 3ZY1321-2AA00 1 5 units 41L

3ZY1321-2AA00
Push-in lugs 3ZY1311-0AA00 1 10 units 41L
For wall mounting

3ZY1311-0AA00

10
Coding pins 3ZY1440-1AA00 1 12 units 41L
For removable terminals of SIRIUS devices
in the industrial DIN-rail enclosure;
enable the mechanical coding of terminals
3ZY1440-1AA00
Hinged cover
Replacement cover, without terminal labeling, titanium gray
• 17.5 mm wide 3ZY1450-1AA00 1 5 units 41L
• 22.5 mm wide 3ZY1450-1AB00 1 5 units 41L

3ZY1450-1AB00
Blank labels
Unit labeling plates1)
For SIRIUS devices
• 10 mm x 7 mm, titanium gray 3RT2900-1SB10 100 816 units 41B
• 20 mm x 7 mm, titanium gray 3RT2900-1SB20 100 340 units 41B
IC01_00181

3RT2900-1SB20
Tools for opening spring-loaded terminals
Screwdrivers Spring-loaded
For all SIRIUS devices with spring-loaded terminals terminals (push-in)

Length approx. 200 mm, 3RA2908-1A 1 1 unit 41B


3.0 mm x 0.5 mm,
3RA2908-1A titanium gray/black,
partially insulated
1) PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH,
see page 16/18.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 10/35
© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP20 timing relays, 45 mm

■ Overview
Multifunction
The functions of the 3RP2005 multifunctional timing relays can
be set by means of the function selector switch. Insert labels can
be used to adjust different functions of the timing relay clearly
LED for indicating
"Timing relay energized" and unmistakably. The corresponding labels can be ordered as
an accessory. The same potential must be applied to terminals

IC01_00376
(left)
LED for indicating A. and B.
"Relay switched" Function selector
(right) For functions, see 3RP2901 label set, page 10/41.
switch
Time setting
Note:
Time setting
range selector range adjuster,
switch The activation of loads parallel to the start input is not
analog
permissible when using AC control voltage.
Unit labeling
plate
L1 L1

S1 K1 S1

SIRIUS 3RP20 timing relay


SIRIUS 3RP20 electronic timing relays for use in control systems A1 B1 A1 B1
and mechanical engineering with: K2 K1 K2 K1
A2 A2
• 1 or 2 CO contacts
N N
• Multifunction or monofunction IC01_00792

• Wide voltage range or combination voltage


• Single or selectable time setting ranges Diagrams
• Switch position indication and voltage indication by LED Accessories
Standards
The timing relays comply with:
• IEC 60721-3-3 "Classification of environmental conditions"
• IEC 61812-1 "Specified time relays for industrial use"
• IEC 61000-6-2 and IEC 61000-6-4 "Electromagnetic
compatibility"
• IEC 60947-5-1 "Low-voltage switchgear and controlgear –
Electromechanical control circuit devices"
10

• IEC 60947-1, Annex N "Protective separation"

Label set for marking the multifunctional relay

Article number scheme


Product versions Article number
SIRIUS timing relays, 45 mm enclosure 3RP20 @ @ – @ @ @ 3 0
Product function/ Multifunction 0 5 15 time ranges 0.05 s ... 100 h
time setting ranges ON-delay 2 5 15 time ranges 0.05 s ... 100 h
Connection type Screw terminals 1
Spring-loaded terminals 2
Contacts 1 CO A
2 CO B
Control supply voltage 24 V AC/DC/100 ... 127 V AC Q Combination voltage
24 V AC/DC/200 ... 240 V AC P Combination voltage
24 ... 240 V AC/DC W Wide voltage range
Example 3RP20 0 5 – 1 A P 3 0
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

10/36 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP20 timing relays, 45 mm

■ Benefits
• Suitable for 3RT miniature contactors • Labels are used on the multifunctional timing relay to
• Uniform design document the function that has been set
• Ideal for small distance between DIN rails and/or for low
mounting depth, e.g. in control boxes

■ Application
Timing relays are used in control, starting, and protective circuits
for all switching operations involving time delays. They
guarantee a high level of functionality and a high repeat
accuracy of timer settings.

■ Technical specifications
More information
Technical specifications, see Internal circuit diagrams, see CAx Download Manager
https://support.industry.siemens.com/cs/ww/en/ps/16356/td https://support.industry.siemens.com/my/ww/en/CAxOnline#CAxOnline
Operating Instructions, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16356/faq
https://support.industry.siemens.com/cs/ww/en/view/11647144

Type 3RP2005,
3RP2025
Dimensions (W x H x D) mm 45 x 57 x 73
H

Rated insulation voltage V AC 300


Pollution degree 3
Overvoltage category III
Permissible ambient temperature
• During operation °C -25 ... +60
• During storage °C -40 ... +85
Operating range of excitation1) 0.85 ... 1.1 x Us at AC; 0.8 ... 1.25 x Us at DC;
0.95 ... 1.05 times the rated frequency
Mechanical endurance Operating 10 x 106
cycles
Electrical endurance at Ie Operating 1 x 105
cycles

10
Connection type Screw terminals

• Terminal screw M3 (for standard screwdriver, size 2 and Pozidriv 2)


• Solid mm2 2 x (0.5 ... 1.5)2), 2 x (0.75 ... 2.5)2)
• Finely stranded with end sleeve mm2 2 x (0.5 ... 1.5)2), 2 x (0.75 ... 2.5)2)
• Stranded AWG 2 x (0.5 ... 1.5)2), 2 x (0.75 ... 2.5)2)
• AWG cables AWG 2 x (18 ... 14)
• Tightening torque Nm 0.8 ... 1.2
Connection type Spring-loaded terminals

• Solid mm2 2 x (0.25 ... 2.5)


• Finely stranded with end sleeve mm2 2 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 2 x (0.25 ... 2.5)
• AWG cables, solid or stranded AWG 2 x (24 ... 14)
• Max. external diameter of the conductor insulation mm 3.6
1) If nothing else is stated.
2) If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in one of the ranges specified.

Siemens IC 10 · 2023 10/37


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP20 timing relays, 45 mm
3RP20 function diagrams and 3RP2901 label set
1 CO contact

A1/A2 A1/A2
>t

NSB0_00861a
>35 ms

NSB0_00862
NSB0_00858
A1/A2 A1/A2

NSB0_00859
B1/A2 B1/A2
15/18 15/18
15/16 15/18 15/18 15/16
t 15/16 15/16 t t
t t t

A B1) C D
3RP2005-.A, 3RP2025 3RP2005-.A 3RP2005-.A 3RP2005-.A
ON-delay OFF-delay with control signal ON-delay and OFF-delay Flashing, starting with interval
with control signal (t = ton = toff) (pulse/interval 1:1)

A1/A2 A1/A2 A1/A2


t1 t3
NSB0_00864

A1/A2 > 35 ms > 35 ms t2

NSB0_00867

NSB0_00868
NSB0_00865
B1/A2 B1/A2 B1/A2
15/18
15/16 15/18 15/18 15/18
t 15/16 15/16 15/16
t t t

E F1) G H
3RP2005-.A 3RP2005-.A 3RP2005-.A 3RP2005-.A
Passing make contact Passing break contact with Pulse-forming with control signal Additive ON-delay with control signal
control signal (pulse generation at the output does
not depend on duration of energizing)

Legend
A ... H Identification letters for 3RP2005
Timing relay energized
Contact closed
Contact open
1) A new control signal at terminal B, after the operating time has started,
resets the operating time to zero (retriggerable).
10

10/38 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP20 timing relays, 45 mm
2 CO contacts

A1/A2 A1/A2
A1/A2 A1/A2 > 35 ms > 35ms
15/18 B1/A2 B1/A2
15/18

NSB0_00871d
15/16 15/16 15/18

NSB0_00873a
15/18

NSB0_00872
t 15/16

NSB0_00874
25/28 15/16
25/26 21/24 25/28 t
t 21/22 25/26 21/24
t 21/22

A A! B1) B!1)
3RP2005-.B 3RP2005-.B 3RP2005-.B 3RP2005-.B
ON-delay ON-delay and instantaneous contact OFF-delay with control signal OFF-delay with control signal
and instantaneous contact

A1/A2 A1/A2
>t >t A1/A2 A1/A2
B1/A2 B1/A2 15/18 15/18

NSB0_00878
15/18 15/16

NSB0_00879
15/18 15/16
IC01_00739

15/16 NSB0_00877a
15/16 25/28 t t
25/28 t t 25/26 21/24
25/26 21/24 t t 21/22
t t 21/22

C C! D D!
3RP2005-.B 3RP2005-.B 3RP2005-.B 3RP2005-.B
ON-delay and OFF-delay ON-delay and OFF-delay Flashing, starting with interval Flashing, starting with interval
with control signal (t = ton = toff) with control signal and instantaneous (pulse/interval 1:1) (pulse/interval 1:1) and instantaneous
contact (t = ton = toff) contact

A1/A2 A1/A2
A1/A2 > 35ms >35ms
A1/A2
B1/A2 B1/A2
15/18 15/18
NSB0_00880

15/16 15/18
NSB0_00881

15/16 15/18
NSB0_00882

t 15/16

NSB0_00883
25/28 15/16
25/26 21/24 25/28 t
t 21/22 25/26 21/24
21/22
t

E E! F1) F!1)
3RP2005-.B 3RP2005-.B 3RP2005-.B 3RP2005-.B
Passing make contact Passing make contact and Passing break contact with control Passing break contact with control

10
instantaneous contact signal signal and instantaneous contact

A1/A2 A1/A2 A1/A2


> 35ms >35ms t1 t3
t2 A1/A2
B1/A2 B1/A2 B1/A2
NSB0_00888

15/18 17/18
15/18 15/18
NSB0_00884

15/16
NSB0_01381a
NSB0_00885

15/16 15/16 27/28


25/28 t t t 50ms
25/26 21/24 21/24
21/22 21/22
t

G G! H! *
3RP2005-.B 3RP2005-.B 3RP2005-.B 3RP2005-.B
Pulse-forming with control signal Pulse-forming with control signal Additive ON-delay with control signal Star-delta (wye-delta) function
(pulse generation at the output does and instantaneous contact (pulse and instantaneous contact
not depend on duration of energizing) generation at the output does not
depend on duration of energizing)

Legend
A ... H Identification letters for 3RP2005
! instantaneous contact

Timing relay energized


Contact closed
Contact open
1) A new control signal at terminal B, after the operating time has started,
resets the operating time to zero (retriggerable).

Siemens IC 10 · 2023 10/39


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP20 timing relays, 45 mm

■ Selection and ordering data


PU (UNIT, SET, M) = 1
PS* = 1 unit
PG = 41H

3RP2005-1AP30 3RP2005-1BW30 3RP2005-2AP30 3RP2005-2BW30


Version Time setting Rated control supply voltage Us Screw terminals Spring-loaded
range t terminals
50/60 Hz AC DC
Article No. Price Article No. Price
V V per PU per PU
3RP2005 timing relays, multifunction, 15 time setting ranges
The functions can be adjusted by means of rotary switches. The 3RP2505 timing
relay can be set clearly and unmistakably using insert labels for various functions.
The corresponding labels can be ordered as an accessory.
The same potential must be applied to terminals A. and B.
For functions, see 3RP2901 label set, page 10/41.
With LED and 0.05 ... 1 s 24/100 ... 127 24 3RP2005-1AQ30 3RP2005-2AQ30
1 CO contact1), 0.15 ... 3 s 24/200 ... 240 24 3RP2005-1AP30 3RP2005-2AP30
8 functions 0.5 ... 10 s
With LED and 1.5 ... 30 s 24 ... 2403) 24 ... 2404) 3RP2005-1BW30 3RP2005-2BW30
2 CO contacts, 0.05 ... 1 min
16 functions 5 ... 100 s
0.15 ... 3 min
0.5 ... 10 min
1.5 ... 30 min
0.05 ... 1 h
5 ... 100 min
0.15 ... 3 h
0.5 ... 10 h
1.5 ... 30 h
5 ... 100 h
 2)
3RP2025 timing relays, ON-delay, 15 time setting ranges
10

With LED and 0.05 ... 1 s 24/100 ... 127 24 3RP2025-1AQ30 3RP2025-2AQ30
1 CO contact1) 0.15 ... 3 s 24/200 ... 240 24 3RP2025-1AP30 3RP2025-2AP30
0.5 ... 10 s
1.5 ... 30 s
0.05 ... 1 min
5 ... 100 s
0.15 ... 3 min
0.5 ... 10 min
1.5 ... 30 min
0.05 ... 1 h
5 ... 100 min
0.15 ... 3 h
0.5 ... 10 h
1.5 ... 30 h
5 ... 100 h
 2)

Accessories, see page 10/41.


1) Units with protective separation.
2) With  switch position no timing. For test purposes (ON/OFF function)
on site. Relay is constantly on when activated, or relay remains constantly
off when activated. Depending on which function is set.
3) Operating range 0.8 to 1.1 x Us.
4) Operating range 0.7 to 1.1 x Us.

* You can order this quantity or a multiple thereof.


10/40 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Monitoring and control devices


Relays
Timing relays
SIRIUS 3RP20 timing relays, 45 mm

■ Accessories
Version Function Identifi Use Article No. Price PU PS* PG
cation per PU (UNIT,
letter SET, M)

Label sets for 3RP20


Accessories for 3RP20 (not included in the scope of supply).
The label set can be used to label timing relays with the set function
in English and German.
1 label set • ON-delay A For 3RP2901-0A 1 5 units 41H
(1 unit) • OFF-delay with control signal B devices
with 8 with 1 CO
functions • ON-delay and OFF-delay with C
control signal
• Flashing, starting with interval D
• Passing make contact E
• Passing break contact with F
control signal
3RP2901-0A • Pulse-forming with control signal G
• Additive ON-delay with control H
signal
1 label set • ON-delay A For 3RP2901-0B 1 5 units 41H
(1 unit) • OFF-delay with control signal B devices
with 16 with 2 CO
functions • ON-delay and OFF-delay with C
control signal
• Flashing, starting with interval D
• Passing make contact E
• Passing break contact with F
control signal
• Pulse-forming with control signal G
• ON-delay and instantaneous A•
contact
• OFF-delay with control signal B•
and instantaneous contact
• ON-delay and OFF-delay with C•
control signal and instantaneous
3RP2901-0B contact
• Flashing, starting with interval, D•
and instantaneous contact
• Passing make contact and E•
instantaneous contact

10
• Passing break contact with F•
control signal and instantaneous
contact
• Pulse-forming with control signal G•
and instantaneous contact
• Additive ON-delay with control H•
signal and instantaneous
contact
• Star-delta (wye-delta) function *
Blank labels
Unit labeling plates1) For 3RP20
For SIRIUS devices
• 20 mm x 7 mm, titanium gray 3RT2900-1SB20 100 340 units 41B
IC01_00181

3RT2900-1SB20
1) PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH,
see page 16/18.

* You can order this quantity or a multiple thereof.


Illustrations are approximate Siemens IC 10 · 2023 10/41
© Siemens 2023

Monitoring and control devices


Relays
Timing relays
7PV15 timing relays, 17.5 mm

■ Overview
Multifunction
The functions of the 7PV1508-1A multifunctional timing relay can
be set by means of rotary switches. The identification letters A to
G are printed on the front alongside the rotary selector switch of
the unit. The related function can be found in the form of a bar
graph on the side of the device.
Enclosure version
All timing relays are suitable for snap-on mounting on TH 35
DIN rails according to IEC 60715. The enclosure complies with
DIN 43880, 1 MW.

17,5 67

7PV15 timing relay

90,5

67,5
45
Electronic timing relays for general use in control systems,
mechanical engineering and infrastructure with:
• 1 or 2 CO contacts
• Multifunction or monofunction NSB0_02042a

• Wide voltage range or combination voltage 5 25


• Single or selectable time setting ranges 43

• Switch position indication and voltage indication by LED


Dimensions
Standards
Note:
The timing relays comply with:
The activation of loads parallel to the start input is not
• IEC 60721-3-3 "Classification of environmental conditions" permissible when using AC control voltage.
• IEC 61812-1 "Specified time relays for industrial use"
• IEC 61000-6-2 and IEC 61000-6-4 "Electromagnetic L1 L1
compatibility"
• IEC 60947-5-1 "Low-voltage switchgear and controlgear – S1 K1 S1
Electromechanical control circuit devices"
10

• DIN 43880 "Built-in equipment for electrical installations;


overall dimensions and related mounting dimensions" A1 B1 A1 B1
K2 K1 K2 K1
A2 A2
N N
IC01_00792

Diagrams

10/42 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
7PV15 timing relays, 17.5 mm
Article number scheme
Product versions Article number
Timing relays in industrial enclosure, 17.5 mm 7PV15 @ @ – 1 @ @ 3 0
Product function/ Multifunction 0 8 7 time ranges 0.05 s ... 100 h
time setting ranges ON-delay 1 1 1 time range 0.05 ... 1 s
1 2 1 time range 0.5 ... 10 s
1 3 1 time range 5 ... 100 s
1 8 7 time ranges 0.05 s ... 100 h
OFF-delay with control signal 3 8 7 time ranges 0.05 s ... 100 h
OFF-delay without control signal 4 0 7 time ranges 0.05 s ... 100 s
Clock-pulse relay 5 8 7 time ranges 0.05 s ... 100 h
Star-delta (wye-delta) function 7 8 7 time ranges 0.05 s ... 100 h
Contacts e.g. A = 1 CO @
Control supply voltage e.g. W = 12 ... 240 V AC/DC @ Combination voltage
Example 7PV15 0 8 – 1 A W 3 0
Note:
The article number scheme shows an overview of product For your orders, please use the article numbers quoted in the
versions for better understanding of the logic behind the article selection and ordering data.
numbers.

■ Benefits
• Wide voltage range 12 to 240 V AC/DC • High level of functionality and a high repeat accuracy of
• High switching capacity, e.g. AC-15 at 230 V, 3 A timer settings
• Combination voltage, e.g. 24 V AC/DC and 200 to 240 V AC • Integrated surge suppressor
• Changes to the time setting range during operation • Function charts printed on the side of the device for reliable
device adjustment
• Changes to the function in the de-energized state

■ Application
Timing relays are used in control, starting and protective circuits
for all switching operations involving time delays, e.g. in
functional buildings, airports, building industry, etc.

■ Technical specifications
More information

10
Technical specifications, see Operating Instructions and internal circuit diagrams, see
https://support.industry.siemens.com/cs/ww/en/ps/16358/td https://support.industry.siemens.com/cs/ww/en/view/35210295
TIA Selection Tool Cloud (TST Cloud), see
www.siemens.com/tstcloud/?node=SIRIUSRelais

Type 7PV15
Rated insulation voltage V AC 300
Pollution degree 2, overvoltage category III
Permissible ambient temperature
• During operation °C -25 ... +55
• During storage °C -40 ... +70
Operating range of excitation1) 0.85 ... 1.1 x Us
Rated operational current Ie
• AC-15 at 24 ... 240 V, 50 Hz A 3
• DC-13 at
- 24 V A 1
- 125 V A 0.2
Uninterrupted thermal current Ith A 5
Mechanical endurance Operating 1 x 107
cycles
Electrical endurance at Ie Operating 1 x 105
cycles
Connection type Screw terminals

• Terminal screw M3 (for standard screwdriver, size 2 and Pozidriv 2)


• Solid mm2 1 x (0.2 ... 2.5)
• Finely stranded with end sleeve mm2 1 x (0.25 ... 1.5)
• Finely stranded without end sleeve mm2 1 x (0.2 ... 1.5)
• AWG cables, solid or stranded AWG 1 x (24 ... 14)
• Tightening torque Nm 0.4 ... 0.5
1) If nothing else is stated.

Siemens IC 10 · 2023 10/43


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
7PV15 timing relays, 17.5 mm
7PV15 function diagrams
1 CO contact

A1/A2 250 ms
>35 ms

NSB0_00862
NSB0_00858
A1/A2 A1/A2

NSB0_00859

IC01_00551
B1/A2 A1/A2
15/18 15/18
15/16 15/18 15/18 15/16
t 15/16 15/16 t t
t t

A B1) -- C
7PV1508-1A, 7PV1511, 7PV1512, 7PV1508-1A, 7PV1538 7PV1540 7PV1508-1A
7PV1513, 7PV1518
ON-delay OFF-delay with control signal OFF-delay without control signal Flashing, starting with interval
(pulse/interval 1:1)

NSB0_00864
A1/A2 A1/A2
NSB0_00863

A1/A2 A1/A2 > 35 ms > 35 ms

NSB0_00867
NSB0_00865
15/18 B1/A2 B1/A2
15/18
15/16 15/16 15/18 15/18
t 15/16 15/16
Dead time Pulse time t t

-- D E1) F
7PV1558 7PV1508-1A 7PV1508-1A 7PV1508-1A
Clock-pulse, starting with interval Passing make contact Passing break contact with control Pulse-forming with control signal
(dead time, pulse time, and time signal (pulse generation at the output does
setting ranges each separately not depend on duration of energizing)
adjustable)

A1/A2
t1 t2 t3
NSB0_00868

B1/A2
15/18
15/16
t
10

G
7PV1508-1A
Additive ON-delay with control signal

Legend
A ... G Identification letters for 7PV1508
Timing relay energized
Contact closed
Contact open
1) A new control signal at terminal B, after the operating time has started,
resets the operating time to zero (retriggerable).
Note:
With the 7PV1508-1A multifunctional timing relay the
identification letters A to G are printed on the front alongside the
rotary selector switch of the unit. The related function can be
found in the form of a bar graph on the side of the device.

10/44 Siemens IC 10 · 2023


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
7PV15 timing relays, 17.5 mm
2 CO contacts

A1/A2
A1/A2 > 35 ms A1/A2 A1/A2
15/18 B1/A2 15/18 15/18

NSB0_00871d

NSB0_00880
NSB0_00878
15/16 15/16 15/16
15/18

NSB0_00873a
15/16 25/28 25/28
25/28
25/26 25/28 25/26 25/26
t 25/26 t t t
t

A B1) C D
7PV1508-1B 7PV1508-1B 7PV1508-1B 7PV1508-1B
ON-delay OFF-delay with control signal Flashing, starting with interval Passing make contact
(pulse/interval 1:1)

A1/A2 A1/A2
> 35ms >t A1/A2
B1/A2 B1/A2
15/18

IC01_00552
15/18 15/18 15/16
NSB0_00884

IC01_00739
15/16 15/16
25/28
25/28 25/28 25/26
25/26 25/26 t 0,5 s
t t t

F H I
7PV1508-1B 7PV1508-1B 7PV1508-1B
Pulse-forming with control signal ON-delay and OFF-delay with Fixed pulse after ON-delay
(pulse generation at the output control signal
does not depend on duration
of energizing)

2 NO contacts
NSB_02044

A1/A2
15/18
25/28
t 0,05...1s

--
7PV1578

10
Star-delta (wye-delta) function2)

Legend
A ... D, F, H, I Identification letters for 7PV1508
Timing relay energized
Contact closed
Contact open
1) A new control signal at terminal B, after the operating time has started,
resets the operating time to zero (retriggerable).
2) With 7PV1578 the contacts 16 and 26 are not needed for the star-delta
(wye-delta) function.
Note:
With the 7PV1508-1B multifunctional timing relay the
identification letters A to D, F, H, I are printed on the front
alongside the rotary selector switch of the unit. The related
function can be found in the form of a bar graph on the side of
the device.

Siemens IC 10 · 2023 10/45


© Siemens 2023

Monitoring and control devices


Relays
Timing relays
7PV15 timing relays, 17.5 mm

■ Selection and ordering data

7PV1508-1AW30 7PV1512-1AP30 7PV1518-1AW30 7PV1538-1AW30 7PV1540-1AW30 7PV1558-1AW30 7PV1578-1BW30

Version Time setting range t Rated control supply voltage Screw terminals PU PS* PG
adjustable by rotary Us (UNIT,
switch to SET, M)
50/60 Hz AC DC Article No. Price
V V per PU
7PV1508 timing relays, multifunction, 7 time setting ranges
The functions can be adjusted by means of rotary switches. The same potential must be applied to terminals A. and B.
With LED and 0.05 ... 1 s 12 ... 240 12 ... 240 7PV1508-1AW30 1 1 unit 41H
1 CO contact, 0.5 ... 10 s
7 functions 5 ... 100 s
With LED and 30 s ... 10 min 12 ... 240 12 ... 240 7PV1508-1BW30 1 1 unit 41H
2 CO contacts, 3 min ... 1 h
7 functions 30 min ... 10 h
5 ... 100 h
7PV151. timing relays, ON-delay, 1 time setting range
With LED and 0.05 ... 1 s 24/200 ... 240 24 7PV1511-1AP30 1 1 unit 41H
1 CO contact 0.5 ... 10 s 24/100 ... 127 24 7PV1512-1AQ30 1 1 unit 41H
24/200 ... 240 24 7PV1512-1AP30 1 1 unit 41H
5 … 100 s 24/100 ... 127 24 7PV1513-1AQ30 1 1 unit 41H
24/200 ... 240 24 7PV1513-1AP30 1 1 unit 41H
7PV1518 timing relays, ON-delay, 7 time setting ranges
With LED and 0.05 ... 1 s 12 ... 240 12 ... 240 7PV1518-1AW30 1 1 unit 41H
1 CO contact 0.5 ... 10 s
5 ... 100 s
30 s ... 10 min
3 min ... 1 h
30 min ... 10 h
5 ... 100 h
7PV1538 timing relays, OFF-delay, with control signal, 7 time setting ranges
With LED and 0.05 ... 1 s 12 ... 240 12 ... 240 7PV1538-1AW30 1 1 unit 41H
1 CO contact 0.5 ... 10 s
10

5 ... 100 s
30 s ... 10 min
3 min ... 1 h
30 min ... 10 h
5 ... 100 h
7PV1540 timing relays, OFF-delay, without control signal, 7 time setting ranges
With LED and 0.05 ... 1 s 12 ... 240 12 ... 240 7PV1540-1AW30 1 1 unit 41H
1 CO contact1) 0.15 ... 3 s
0.3 ... 6 s
0.5 ... 10 s
1.5 ... 30 s
3 ... 60 s
5 ... 100 s
7PV1558 timing relays, clock-pulse relay, 7 time setting ranges
With LED and 0.05 ... 1 s 12 ... 240 12 ... 240 7PV1558-1AW30 1 1 unit 41H
1 CO contact 0.5 ... 10 s
5 ... 100 s
30 s ... 10 min
3 min ... 1 h
30 min ... 10 h
5 ... 100 h
7PV1578 timing relays, star-delta (wye-delta) function, 7 time setting ranges
With LED and 0.05 ... 1 s 12 ... 240 12 ... 240 7PV1578-1BW30 1 1 unit 41H
2 NO contacts, 0.5 ... 10 s
dead interval 5 ... 100 s
0.05 ... 1 s adjustable 30 s ... 10 min
3 min ... 1 h
30 min ... 10 h
5 ... 100 h
1) Setting of output contacts in as-supplied state not defined (bistable relay).
Application of the control supply voltage once results in contact
changeover to the correct setting.

* You can order this quantity or a multiple thereof.


10/46 Siemens IC 10 · 2023 Illustrations are approximate
© Siemens 2023

Monitoring and control devices


Relays
SIRIUS 3RR21, 3RR22 monitoring relays for mounting on 3RT2 contactors
Current and active current monitoring

■ Overview
The 3RR2 current monitoring relays can be integrated directly in
the feeder by mounting on the 3RT2 contactor; separate wiring
of the main circuit is therefore superfluous. No separate
transformers are required.
For a line-oriented configuration or simultaneous use of an
overload relay, terminal supports for stand-alone installation are
available for separate DIN-rail mounting.
Versions
Basic versions
The basic versions with 2-phase apparent current monitoring,
a CO contact output and analog adjustability provide a high
level of monitoring reliability especially in the rated and overload
range.
SIRIUS 3RR2242, 3RR2142, 3RR2243 current monitoring relays
Standard versions
More information
The standard versions monitor the current in 3 phases with
Homepage, see www.siemens.com/sirius-monitoring-relays selectable active current monitoring. They have additional
Industry Mall, see www.siemens.com/product?3RR21 diagnostics options such as residual-current monitoring and
phase sequence monitoring, and they are also suitable for
monitoring motors below the rated torque. These devices have
an additional independent semiconductor output, an actual
value indicator, and are digitally adjustable.
Both versions are available optionally with screw or spring-
loaded terminals, in each case for sizes S00 and S0.
Video: SIRIUS 3RR2 current monitoring relays With variants of size S2 the main conducting paths always have
screw terminals; the control current side can have screw or
The SIRIUS 3RR2 current monitoring relays are suitable for load spring-loaded terminals.
monitoring of motors or other loads. In 2 or 3 phases they monitor
the rms value of AC currents for overshooting or undershooting Note:
of set threshold values. In addition to the features of the standard versions, the
Whereas apparent current monitoring is used above all in 3RR24 monitoring relays for mounting on 3RT2 contactors for
connection with the rated torque or in case of overload, the IO-Link also offer the possibility of transmitting the measured
active current monitoring option can be used to observe and values and diagnostics data to a controller via an IO-Link.
evaluate the load factor over a motor's entire torque range. Furthermore, the devices can be parameterized on the devices
themselves or via IO-Link.
For more information, see page 10/55 onwards.

10
3RR21 and 3RR22 overview table

Features 3RR21 3RR22 Benefits


General data
Sizes S00, S0, S2 S00, S0, S2 • Are coordinated with the dimensions, connections and
Dimensions in mm technical characteristics of the other devices in the
(W x H x D) SIRIUS modular system (contactors, soft starters, etc.)
H

• Screw terminals S00: 45 x 79 x 80, S00: 45 x 79 x 80, • Permit the mounting of slim-line and compact load
S0: 45 x 87 x 91, S0: 45 x 87 x 91, feeders in widths of 45 mm (S00 and S0) and 55 mm
D

W
S2: 55 x 99 x 112 S2: 55 x 99 x 112 (S2)
• Simplify configuration
• Spring-loaded S00: 45 x 90 x 80, S00: 45 x 90 x 80,
terminals S0: 45 x 109 x 92, S0: 45 x 109 x 92,
S2: 55 x 99 x 112 S2: 55 x 99 x 112
Current range S00: 1.6 ... 16 A S00: 1.6 ... 16 A • Is adapted to the other devices in the SIRIUS modular
S0: 4 ... 40 A S0: 4 ... 40 A system
S2: 8 ... 80 A S2: 8 ... 80 A • Just a single version per size with a wide setting range
enables easy configuration
Permissible ambient temperature
During operation -25 ... +60 °C -25 ... +60 °C • Suitable for applications in the control cabinet,
worldwide

Siemens IC 10 · 2023 10/47


© Siemens 2023

Monitoring and control devices


Relays
SIRIUS 3RR21, 3RR22 monitoring relays for mounting on 3RT2 contactors
Current and active current monitoring

Features 3RR21 3RR22 Benefits


Monitoring functions
Current overshoot ✓ ✓ • Provides optimum inverse-time delayed protection of
(2-phase) (3-phase) loads against excessive temperature rises due to
overload
• Enables detection of filter blockages or pumping
against closed gate valves
• Enables drawing conclusions about wear, poor
lubrication or other maintenance-relevant phenomena
Current undershoot ✓ ✓ • Enables detection of underload due to a slipping or
(2-phase) (3-phase) torn belt
• Guarantees protection of pumps against dry running
• Facilitates monitoring of the functions of resistive loads
such as heaters
• Permits energy savings through monitoring of no-load
operation
Apparent current monitoring ✓ ✓ • Precision current monitoring especially in a motor's
(Selectable) rated and upper torque range
Active current monitoring -- ✓ • Optimum current monitoring over a motor's entire
(Selectable) torque range through the patented combination of
power factor and apparent current monitoring
Range monitoring ✓ ✓ • Simultaneous monitoring of current overshoot and
(2-phase) (3-phase) undershoot with a single device
Phase failure, open circuit ✓ ✓ • Minimizes heating of three-phase motors during phase
(2-phase) (3-phase) failure through immediate disconnection
• Prevents operation of hoisting equipment with half the
load carrying capacity
Phase sequence monitoring -- ✓ • Prevents starting of motors, pumps or compressors in
(Selectable) the wrong direction of rotation
Internal ground-fault detection -- ✓ • Provides optimum protection of loads against high-
(residual-current monitoring) (Selectable) resistance ground faults due to moisture, condensed
water, damage to the insulation material, etc.
• Eliminates the need for additional special equipment
and thus space in the control cabinet
• Reduces wiring overhead and costs
10

Blocking current monitoring -- ✓ • Minimizes heating of three-phase motors when blocked


(Selectable) during operation through immediate disconnection
• Minimizes mechanical loading of the system by acting
as an electronic shear pin
Features
RESET function ✓ ✓ • Allows manual or automatic resetting of the relay
• Resetting directly on the device or by switching the
control supply voltage off and on
(Remote RESET)
ON-delay time 0 ... 60 s 0 ... 99 s • Enables motor starting without evaluation of the starting
current
• Can be used for monitoring motors with lengthy startup
Tripping delay time 0 ... 30 s 0 ... 30 s • Permits brief threshold value violations during
operation
• Prevents frequent warnings and disconnections with
currents near the threshold values
Operating and indicating elements LEDs and Displays and buttons • For setting the threshold values and delay times and for
rotary potentiometers fast and targeted diagnostics
• For selectable functions
• Displays for permanent display of measured values
Integrated contacts 1 CO contact 1 CO contact, • Enable disconnection of the sy