Part No. 060435-10, Rev.
R
October 2022
                  OmniSwitch 6865
                Hardware Users Guide
                             www.al-enterprise.com
This user guide documents OmniSwitch 6865 hardware, including chassis and associated components. The
specifications described in this guide are subject to change without notice.
The Alcatel-Lucent name and logo are trademarks of Nokia used under license by ALE. To view other
trademarks used by affiliated companies of ALE Holding, visit: www.al-enterprise.com/en/legal/
trademarks-copyright. All other trademarks are the property of their respective owners. The information
presented is subject to change without notice. Neither ALE Holding nor any of its affiliates assumes any
responsibility for inaccuracies contained herein. © Copyright 2022 ALE International, ALE USA Inc. All
rights reserved in all countries.
                                        26801 West Agoura Road
                                          Calabasas, CA 91301
                                   (818) 880-3500 FAX (818) 880-3505
                                Service & Support Contact Information
                                      North America: 800-995-2696
                                      Latin America: 877-919-9526
                         EMEA: +800 00200100 (Toll Free) or +1(650)385-2193
                                       Asia Pacific: +65 6240 8484
                                     Web: myportal.al-enterprise.com
                           Email: ebg_global_supportcenter@al-enterprise.com
Contents
                     About This Guide ........................................................................................................... v
Chapter 1            Getting Started and Installation ........................................................................... 1-1
                     Getting Started ................................................................................................................1-1
                         Preparing for the Installation ....................................................................................1-1
                         Providing Air Flow and Minimum Recommended Clearances ............................... 1-3
                         Items Included .......................................................................................................... 1-4
                     Preparing the Chassis and Power Supply Tray Assembly .............................................. 1-4
                         Side Mount Power Supply Tray ...............................................................................1-4
                         Rear Mount Power Supply Tray ...............................................................................1-5
                         Attaching Rack Mount Flanges ................................................................................1-7
                         Attaching Table Mount Feet ....................................................................................1-7
                     Installing Power Supplies ................................................................................................1-8
                          Installing Power Supplies for Side Mount Trays .....................................................1-9
                          Installing Power Supplies for Rear Mount Trays ...................................................1-10
                     Mounting the OmniSwitch 6865 ...................................................................................1-12
                        Rack Mounting ....................................................................................................... 1-12
                        Table Mounting ...................................................................................................... 1-15
                        DIN Rail Mounting - Power Supply ...................................................................... 1-16
                        DIN Rail Mounting - Chassis .................................................................................1-17
                        DNV Mounting Steps ............................................................................................. 1-19
                     Additional DIN / Wall Mounting Examples .................................................................1-25
                     Connections and Cabling ..............................................................................................1-28
                        System and Port LEDs ........................................................................................... 1-29
                        The First Login Session .......................................................................................... 1-30
                        Unlocking Session Types ....................................................................................... 1-31
                        Changing the Login Password ................................................................................1-31
                        Setting the System Time Zone ...............................................................................1-32
                        Setting the Date and Time ...................................................................................... 1-32
                        Setting Optional Parameters ...................................................................................1-32
Chapter 2            Chassis and Power .....................................................................................................2-1
                     OmniSwitch 6865-P16X .................................................................................................2-1
                       Chassis Front Panel ..................................................................................................2-3
                       Chassis Rear Panel ...................................................................................................2-4
                     OmniSwitch 6865-U12X ................................................................................................2-4
                       Chassis Front Panel ..................................................................................................2-5
                       Chassis Rear Panel ...................................................................................................2-6
                     OmniSwitch 6865-U28X ................................................................................................2-6
                       Chassis Front Panel ..................................................................................................2-7
OmniSwitch 6865 Hardware Users Guide          October 2022                                                                                           iii
                                                                                                                                    Contents
                   Chassis Rear Panel ...................................................................................................2-8
             Power Supplies ................................................................................................................2-8
                OS6865-BP - 180W AC Power Supply ...................................................................2-8
                OS6865-BP-D - 180W/140W DC Power Supply ....................................................2-9
             DC Power Supply Connection ...................................................................................... 2-10
                Connecting a DC Cable Harness to the Chassis Power Supply ............................. 2-10
                Connecting a DC Cable Harness to the DC Power Source ....................................2-10
                Connecting a DC Power Source ............................................................................. 2-11
             Dying Gasp ....................................................................................................................2-12
                Scenarios ................................................................................................................2-13
                SNMP Trap ............................................................................................................ 2-13
                Syslog Message ...................................................................................................... 2-13
                Link OAM PDU ..................................................................................................... 2-13
Chapter 3    Power Over Ethernet (PoE) ......................................................................................3-1
             Managing Power over Ethernet (PoE) ............................................................................ 3-1
                Power over Ethernet Budget ....................................................................................3-1
                Determining the Power Available for Powered Devices (PDs) ............................... 3-2
                PoE Operational Status ............................................................................................. 3-3
                Understanding Priority Disconnect .......................................................................... 3-7
Appendix A   Regulatory Compliance and Safety Information A-1
             Declaration of Conformity: CE Mark ............................................................................ A-1
             Compliance and Certifications ....................................................................................... A-1
                Safety Standards ...................................................................................................... A-1
                EMI/EMC Standards ............................................................................................... A-2
                Industrial Compliance Requirements ...................................................................... A-3
                China RoHS: Hazardous Substance Table .............................................................. A-5
                Taiwan RoHS: Hazardous Substance Table ............................................................ A-6
                California Proposition 65 Warning ......................................................................... A-6
                Waste Electrical and Electronic Equipment (WEEE) Statement ............................ A-7
                FCC Class A, Part 15 .............................................................................................. A-7
                JATE ........................................................................................................................ A-8
                CISPR22 Class A Warning ..................................................................................... A-8
                Korea Emissions Statement ..................................................................................... A-8
                VCCI ....................................................................................................................... A-8
                Class A Warning for Taiwan and Other Chinese Markets ...................................... A-8
                Translated Safety Warnings .................................................................................... A-9
                Instrucciones de seguridad en español .................................................................. A-13
iv                                                                    OmniSwitch 6865 Hardware Users Guide                     October 2022
                                                       About This Guide
    This OmniSwitch 6865 Hardware Users Guide describes OmniSwitch 6560 switch components and basic
    switch hardware procedures.
Supported Platforms
    The information in this guide applies only to OmniSwitch 6865 switches.
Who Should Read this Manual?
    The audience for this users guide is network administrators and IT support personnel who need to
    configure, maintain, and monitor switches and routers in a live network. However, anyone wishing to gain
    knowledge of the hardware will benefit from the material in this guide.
When Should I Read this Manual?
    Read this guide as soon as you are ready to familiarize yourself with your switch hardware components.
    You should already be familiar with the very basics of the switch hardware, such as module LEDs and
    component installation procedures. This manual will help you understand your switch hardware in
    greater depth.
OmniSwitch 6865 Hardware Users Guide   October 2022                                                          v
What is in this Manual?
     This users guide includes the following hardware-related information:
     • Descriptions of “Availability” features.
     • Technical specifications for the chassis, power supplies and modules.
     • Power supply requirements.
     • The dynamics of chassis airflow, including detailed illustrations of proper and improper airflow
        configurations.
     • Hot-swapping power supplies and modules.
     • Installation and removal procedures for power supplies and modules.
     • Detailed illustrations and LED descriptions for chassis, network and power supply operability.
     • Hardware-related Command Line Interface (CLI) commands.
What is Not in this Manual?
     The descriptive and procedural information in this manual focuses on switch hardware. It includes
     information on some CLI commands that pertain directly to hardware configuration, but it is not intended
     as a software users guide. There are several OmniSwitch users guides that focus on switch software
     configuration. Consult those guides for detailed information and examples for configuring your switch
     software to operate in a live network environment. See “Documentation Roadmap” on page -vii and
     “Related Documentation” on page -ix for further information on software configuration guides available
     for your switch.
How is the Information Organized?
     Each chapter in this guide focuses on a specific hardware component or a set of hardware components. All
     descriptive, technical specification, and procedural information for a hardware component can be found in
     the chapter dedicated to that component.
vi                                                          OmniSwitch 6865 Hardware Users Guide   October 2022
Documentation Roadmap
    The OmniSwitch user documentation suite was designed to supply you with information at several critical
    junctures of the configuration process.The following section outlines a roadmap of the manuals that will
    help you at each stage of the configuration process. Under each stage, we point you to the manual or
    manuals that will be most helpful to you.
    Stage 1: Using the Switch for the First Time
    Pertinent Documentation: Getting Started Information
                             OmniSwitch Release Notes
    A “Getting Started” chapter is included in the OmniSwitch 6560 Hardware Users Guide. This chapter
    provides all the information you need to get your switch up and running the first time. It also includes
    succinct overview information on fundamental aspects of the switch.
    At this time you should also familiarize yourself with the Release Notes that accompanied your switch.
    This document includes important information on feature limitations that are not included in other
    user guides.
    Stage 2: Gaining Familiarity with Basic Switch Functions
    Pertinent Documentation: Hardware Users Guide
                             OmniSwitch Switch Management Guide
    Once you have your switch up and running, you will want to begin investigating basic aspects of its
    hardware and software. Information about switch hardware is provided in the OmniSwitch 6560 Hardware
    Guide. This guide provide specifications, illustrations, and descriptions of all hardware components. It also
    includes steps for common procedures, such as removing and installing switch components.
    This guide is the primary users guide for the basic software features on a single switch. This guide
    contains information on the switch directory structure, basic file and directory utilities, switch access
    security, SNMP, and web-based management. It is recommended that you read this guide before
    connecting your switch to the network.
    Stage 3: Integrating the Switch Into a Network
    Pertinent Documentation: OmniSwitch Network Configuration Guide
    When you are ready to connect your switch to the network, you will need to learn how the OmniSwitch
    implements fundamental software features, such as 802.1Q, VLANs, Spanning Tree, and network routing
    protocols. The Network Configuration Guide guide contains overview information, procedures, and
    examples on how standard networking technologies are configured on the OmniSwitch.
OmniSwitch 6865 Hardware Users Guide    October 2022                                                            vii
       Anytime
       The OmniSwitch CLI Reference Guide contains comprehensive information on all CLI commands
       supported by the switch. This guide includes syntax, default, usage, example, related CLI command, and
       CLI-to-MIB variable mapping information for all CLI commands supported by the switch. This guide can
       be consulted anytime during the configuration process to find detailed and specific information on each
       CLI command.
viii                                                         OmniSwitch 6865 Hardware Users Guide   October 2022
Related Documentation
    The following are the titles and descriptions of all the OmniSwitch user guides:
    • Hardware Users Guide
       Complete technical specifications and procedures for all OmniSwitch chassis, power supplies, fans, and
       Network Interface (NI) modules.
    • OmniSwitch CLI Reference Guide
       Complete reference to all CLI commands supported on the OmniSwitch. Includes syntax definitions,
       default values, examples, usage guidelines and CLI-to-MIB variable mappings.
    • OmniSwitch Switch Management Guide
       Includes procedures for readying an individual switch for integration into a network. Topics include the
       software directory architecture, image rollback protections, authenticated switch access, managing
       switch files, system configuration, using SNMP, and using web management software (WebView).
    • OmniSwitch Network Configuration Guide
       Includes network configuration procedures and descriptive information on all the major software
       features and protocols included in the base software package. Chapters cover Layer 2 information
       (Ethernet and VLAN configuration), Layer 3 information (routing protocols, such as RIP and IPX),
       security options (authenticated VLANs), Quality of Service (QoS), link aggregation, and server
       load balancing.
    • Technical Tips, Field Notices
       Includes information published by Alcatel-Lucent’s Customer Support group.
    • Release Notes
       Includes critical Open Problem Reports, feature exceptions, and other important information on the
       features supported in the current release and any limitations to their support.
OmniSwitch 6865 Hardware Users Guide   October 2022                                                          ix
Technical Support
    A service agreement brings your company the assurance of 7x24 no-excuses technical support. You’ll also
    receive regular software updates to maintain and maximize your product’s features and functionality and
    on-site hardware replacement through our global network of highly qualified service delivery partners.
    With 24-hour access to the Service and Support web page, you’ll be able to view and update any case
    (open or closed) that you have reported to technical support, open a new case or access helpful release
    notes, technical bulletins, and manuals.
    Access additional information can be found below:
            Web: myportal.al-enterprise.com
            Phone: 1-800-995-2696
            Email: ebg_gloabl_supportenter@al-enterprise.com
x                                                           OmniSwitch 6865 Hardware Users Guide    October 2022
1           Getting Started and Instal-
                                 lation
Getting Started
Preparing for the Installation
Alcatel-Lucent Enterprise products must be installed by a professional installer. It is the
responsibility of the installer to comply with product specifications and all applicable local and
national codes.
When preparing for installation, unpack the product as close as possible to the location where it
will be installed.
                 Caution: An operating Omniswitch may be hot to the touch.
Elevated Operating Ambient Temperature
If installed in a closed or multi-rack assembly, the operating ambient temperature of the rack
environment may be greater than the room’s ambient temperature. Therefore, consideration
should be given to the maximum rated ambient temperature (Tmra). When operating at 74°C
ambient temperature the switch must be installed in a suitable closed rack or cabinet enclosure.
Reduced Air Flow
Installation of the equipment should be such that the amount of air flow required for safe
operation of the equipment is not compromised. Refer to “Providing Air Flow and Minimum
Recommended Clearances” on page 1-3 for more information.
Mechanical Loading
Mounting of the equipment in the rack should be such that a hazardous condition is not achieved
due to uneven loading.
OmniSwitch 6865 Hardware Users Guide   October 2022                                          page 1-1
Getting Started                                                                      Getting Started and Installation
Circuit Overloading
Consideration should be given to the connection of the equipment to the supply circuit and the
effect that overloading of circuits could have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.
Reliable Earthing
Reliable earthing of rack mounted equipment should be maintained. Particular attention should be
given to supply connections other than direct connections to the branch (e.g., use of power strips).
Additional Electrical Requirements
The switches have the following general electrical requirements:
• AC and DC power supply support
• Each supplied AC power cord is 2 meters (approx. 6.5 feet). Do not use extension cords.
• Each switch requires one grounded electrical outlet per power supply.
Redundant AC Power. It is recommended that each power supply resides on a separate circuit.
With redundant power, if a single circuit fails, the switch’s remaining power supply (on separate
circuits) can remain operational.
Electrical Surge Warning
In order to help protect equipment against electrical surges please take note of the following
recommendations and guidelines:
1. Earth grounding of all devices is fundamental to ensure long term reliability.
•    All electrical equipment must be installed by a qualified, licensed electrician.
•    Every power supply that is connected to building power should be earth grounded.
•    Earth grounding for the power cable, should be verified to be 0.01 ohm or less.
•    Each switch should be grounded to same earth ground as the power supply.
•    Each powered device, such as an AP or camera, should be connected to earth ground.
•    Each surge suppression device should be connected to earth ground.
2. Shielded cables (STP) offer some minimal level of additional protection over unshielded Ethernet cables
   (UTP) but the use of a surge protector is still recommended.
•    It is suggested to use STP Cat5e or better for 1Gbps Ethernet switches for any outdoor
     application or applications where Ethernet cables come in close proximity to alternating
     current conductors.
•    Always install cables according to manufacturer requirements.
3. For any connections where integrity of the cabling within a building ground is questionable (i.e outdoor
   connections), copper Ethernet ports must be connected with an appropriate surge protection device, inline,
   between the PSE and PD per the manufacturer’s recommendations for connection and grounding.
4. Caution should be taken for any cable connected to any outdoor device, not only on the device grounding,
   but to ensure that any outdoor device cables that could carry surge currents, do not pass those surge currents
   to upstream Ethernet switches.
page 1-2                                                     OmniSwitch 6865 Hardware Users Guide      October 2022
Getting Started and Installation                                                                         Getting Started
      Caution - Category 5e, Category 6, and Category 6a cables can store large amounts of static electricity due
      to the dielectric properties of their construction materials in addition, this build up of electricity could lead
      to a Cable Discharge Event (CDE). A CDE can occur due to the differential in charges on the cable and the
      equipment it’s being connected to. It is recommended that installers momentarily ground all copper
      Ethernet cables (especially in new cable runs) to a suitable and safe earth ground before connecting them to
      the port.
Note: Failure to follow the above recommendations could result in voiding the warranty of the
affected ALE product.
Providing Air Flow and Minimum Recommended Clearances
•     Switches operating in an environment at or above 65°C require air flow.
•     Switches operating in an environment below 65°C do not require airflow.
•     When mounting the chassis on a flat service (e.g., table) be sure that the top of the switch,
      with the larger heat sinks, is facing out and away from the mounting surface.
•     Be sure to refer to minimum recommended clearances provided in the table below.
    Minimum Recommended Clearances
    Top (Rack mount)                   0.875 inches (1/2 RU) for switches operating in an ambient
                                       temperature below 65°C;
                                       1.75 inches (1 RU) for switches operating in an ambient temperature
                                       at or above 65°C. (See important air flow requirements outlined
                                       above.)
    Top (Table mount)                  0.875 inches; for table mounting, be sure to install the mounting
                                       brackets as described in the section, “Preparing the Chassis and
                                       Power Supply Tray Assembly.”
    Bottom (Rack mount)                No minimum clearance required. However, be sure that the bottom of
                                       the chassis is not in direct contact with any equipment below.
    Bottom (Table mount)               0.875 inches; for table mounting, be sure to install the mounting
                                       brackets as described in the section, “Preparing the Chassis and
                                       Power Supply Tray Assembly.”.
    DNV Installations                  0.875 inches (1/2 RU) for OS6865-U12X and OS6865-P16X that require
                                       a DNV power supply cover, operating between -40°C to 55°C (-40°F to
                                       131°F).
                                       1.75 inches (1 RU) for OS6865-U28X that requires a DNV power supply
                                       cover, operating between -40°C to 55°C (-40°F to 131°F).
    Sides                              2 inches
    Rear                               6 inches
    Front                              6 inches
OmniSwitch 6865 Hardware Users Guide      October 2022                                                         page 1-3
Preparing the Chassis and Power Supply Tray Assembly                                Getting Started and Installation
Items Included
Depending on your order the following items may be included:
• OmniSwitch chassis with power supplies and modules
• Country specific power cord(s)
• Cover Panels
• Rack Mount Brackets
• Product Documentation and Training Cards
• DB9-RJ45 Connector
Preparing the Chassis and Power Supply Tray
Assembly
The power supply tray may be mounted at the side or the rear of the chassis. Side mounted tray
assemblies are typically used for rack mount applications; rear mounted tray assemblies are
typically used for table mount applications.
Side Mount Power Supply Tray
1. To mount the power supply tray to the side of the chassis, be sure that the attachment brackets are installed
   in the proper positions with the Front Chassis and Front Tray brackets aligned.
                                                                         Front Chassis-to-Tray Bracket
       Rear Chassis-to-Tray Bracket
             Front Tray-to-chassis Bracket
             (Aligns with Front Chassis-to-Tray Bracket (See Next Step)
Required Brackets for Side Mount Power Supply Tray (Brackets may be factory-installed.)
page 1-4                                                     OmniSwitch 6865 Hardware Users Guide     October 2022
Getting Started and Installation                              Preparing the Chassis and Power Supply Tray Assembly
2. Align the holes in the power supply tray and fasten the two parts into a single assembly using the
   attachment screws.
                                   2 (M4) Screws
                                                                                  4 (M3) Screws
Rear Mount Power Supply Tray
Note: For rear mount power supply assemblies, factory-installed power tray brackets (shown on
page 4) should be removed.
OmniSwitch 6865 Hardware Users Guide     October 2022                                                     page 1-5
Preparing the Chassis and Power Supply Tray Assembly                                   Getting Started and Installation
1. To mount the power supply tray to the rear of the chassis, insert the tray tabs into the slots at the rear panel
   of the chassis. Once the tabs are inserted and the face of the tray is flush against the chassis rear panel,
   insert and tighten the attachment screws.
                                               OS6865-U12X / P16X
                                                  OS6865-U28X
page 1-6                                                      OmniSwitch 6865 Hardware Users Guide       October 2022
Getting Started and Installation                                Preparing the Chassis and Power Supply Tray Assembly
Attaching Rack Mount Flanges
Before rack mounting, rack mount flanges must be installed at the left and right sides of the
chassis/tray assembly. To attach the flanges, align the holes in with the threaded holes in the side
of the chassis and power supply tray. Insert and tighten the attachment screws.
    Use four (4) screws
    (M4X6mm).
                                                                       Use four (4) screws (M4X6mm)
                                                                       and mounting holes ‘B’(4).
                                       Attaching Rack Mount Flanges
Attaching Table Mount Feet
1. Before table mounting, table mount feet must be installed at the left and right sides of the chassis/tray
   assembly. To install the feet, align the holes with the threaded holes in the sides of the chassis and power
   supply tray, as shown below. Insert and tighten the attachment screws.
Important. Table mount feet provide the 1/2 RU clearance required at the bottom of the chassis.
Do not attempt to operate the OS6865-P16X on a tabletop surface without these feet properly
installed. See “Providing Air Flow and Minimum Recommended Clearances” on page 1-3 for more clear-
ance information.
OmniSwitch 6865 Hardware Users Guide   October 2022                                                         page 1-7
Installing Power Supplies                                                      Getting Started and Installation
                                                                 Use five (5) screws (M4X6mm).
                                                                 Mounting holes ‘D’ (4) and ‘E’
                                                                 (1).
    Use four (4) screws (M4X6mm).
    Mounting holes ‘C’ (4).
                                    Attaching Table Mount Feet
                       Table Mount Assembly with 1/2 RU Space Under Chassis
Installing Power Supplies
Once the chassis and tray are assembled and the mounting brackets are attached, install the
power supplies.
Note. Whenever connecting or disconnecting a power supply to/from a chassis, the power supply
must be disconnected from the power source.
page 1-8                                                OmniSwitch 6865 Hardware Users Guide     October 2022
Getting Started and Installation                                                         Installing Power Supplies
Installing Power Supplies for Side Mount Trays
1. Slide the power supply into the tray and insert the tabs located at the bottom-rear of the power supply into
   the slots at the base of the power supply tray.
2. Align and tighten the thumb screw at the front of the power supply unit.
OmniSwitch 6865 Hardware Users Guide   October 2022                                                      page 1-9
Installing Power Supplies                                                          Getting Started and Installation
3. Plug the power supply-to-chassis connector cable (provided) into the DB-15 connectors located at the rear
   of the power supply and the chassis.
                                               Power Supply-to-Chassis Cable (Pro-
                                               vided)
4. For redundant power supply configurations, repeat these steps for the additional power supply at the other
   side of the power supply tray.
Note. The switch does not provide an on/off switch. Instead, the switch powers on when a power
cord is plugged into the power supply’s front panel and plugged into a power source. Do not con-
nect to a power source until all power supplies and power supply-to-chassis cables are installed
and the switch is ready to boot.
Installing Power Supplies for Rear Mount Trays
1. Orient the power supply as shown below. Insert the guide pins (located on either side of the DB-15
   connector) into the guide holes in the rear of the chassis.
                                                                       Hole for Guide Pin
page 1-10                                                  OmniSwitch 6865 Hardware Users Guide      October 2022
Getting Started and Installation                                                          Installing Power Supplies
                                   For this example, table mount assembly shown.
2. Push the power supply into place until the connector is fully seated and tighten the thumb screw at the front
   of the power supply unit.
3. For redundant power supply configurations, repeat these steps using the power supply connector and thumb
   screw hole located at the other side of the chassis and power supply tray.
Note. The switch does not provide an on/off switch. Instead, the switch powers on when a power
cord is plugged into the power supply’s front panel and plugged into a power source. Do not con-
nect to a power source until all power supplies and power supply-to-chassis cables are installed
and the switch is ready to boot.
OmniSwitch 6865 Hardware Users Guide        October 2022                                                 page 1-11
Mounting the OmniSwitch 6865                                               Getting Started and Installation
                                    Power Cord and Holder
Mounting the OmniSwitch 6865
Rack Mounting
General Rack Mounting Recommendations
•   Install the switch in the rack using the rack manufacturer’s recommended attachment screws
    (not provided). Always follow rack manufacturer’s specifications when installing.
•   Be sure to accommodate spacing requirements when rack mounting the switch. See “Providing
    Air Flow and Minimum Recommended Clearances” on page 1-3 for more information.
•   Pre-marking the holes on the rack where the switch is to be installed can be helpful.
•   Use an additional person to help lift and position the chassis/power supply assembly in the
    rack during installation.
•   To keep the rack from becoming top heavy, install switches toward the bottom of the rack
    first.
•   Use the OS6865-REAR-MNT mounting kit to help secure the rear of the OS6865-U28X.
•   Use the OS6865-TRAY-1U mounting kit to rack-mount two power supply trays side-by-side.
page 1-12                                           OmniSwitch 6865 Hardware Users Guide     October 2022
Getting Started and Installation                                          Mounting the OmniSwitch 6865
                      Attach Side Rails                             Mount Front Brackets
      Slide Rear Brackets into Side Rails and Mount
                         OS6865-REAR-MNT Mounting Kit for OS6865-U28X (Overview)
OmniSwitch 6865 Hardware Users Guide      October 2022                                       page 1-13
Mounting the OmniSwitch 6865                                                            Getting Started and Installation
                                                 (Use M4X6mm Screws)
Bracket Mounting holes ‘C’ (4)
                                                                                                   Tray Mounting Holes ‘A’ (4)
                                                                                                  Chassis Mounting Holes ‘A’ (3)
                                         22.5”
Chassis Mounting Holes ‘C’ (3)
             OS6865-REAR-MNT (Mounting Hole Locations for Chassis and Rear Power Supply Tray)
                                                   (Use M4X6mm
Chassis Mounting Holes ‘B’ (2)                                                                     Chassis Mounting Holes ‘D’ (2)
and Middle Hole (1)                                                                                and Middle Hole (1)
                                      18.3”
                                 OS6865-REAR-MNT (Mounting Hole Locations for Chassis Only)
page 1-14                                                        OmniSwitch 6865 Hardware Users Guide        October 2022
Getting Started and Installation                                                   Mounting the OmniSwitch 6865
                                                 (Use M4X6mm
                                    16”
Tray Mounting Holes ‘B’ (4)                                                                    Tray Mounting Holes ‘D’ (4)
                              OS6865-TRAY-1U (Mounting Hole Locations for Power Supply Tray)
Table Mounting
Important. Table mount feet provide the 1/2 RU clearance required at the bottom of the chassis.
Do not attempt to operate the switch on a tabletop surface without these feet properly installed.
For information on installing, refer to “Attaching Table Mount Feet” on page 1-7.
See “Providing Air Flow and Minimum Recommended Clearances” on page 1-3 for more clearance infor-
mation.
1. Place the assembly on the tabletop surface. Refer to all requirements—including those outlined in the
   “Preparing for the Installation” and “Providing Air Flow and Minimum Recommended Clearances” on
   page 1-3—before placing the switch.
OmniSwitch 6865 Hardware Users Guide          October 2022                                                    page 1-15
Mounting the OmniSwitch 6865                                                            Getting Started and Installation
2. Fasten the assembly to the surface using attachment bolts or screws as appropriate for the
   surface material.
DIN Rail Mounting - Power Supply
The power supply can be mounted on a DIN rail.
1.   Attach DIN rail clip to the power supply using the screws (M4X6mm) provided.
2.   Hook the bottom of the DIN rail clip under the bottom of the DIN rail.
3.   Push up, compressing the tension spring at the bottom of the DIN rail clip.
4.   Once the top of the DIN rail clip is over the top of the DIN rail release the tension on the tension spring and
     ensure the top and bottom of the DIN rail clip are securely attached.
Warning. When mounted vertically, suitable for mounting on concrete or other non-combustible
surfaces only (as shown).
page 1-16                                                      OmniSwitch 6865 Hardware Users Guide       October 2022
Getting Started and Installation                                                      Mounting the OmniSwitch 6865
       DIN Rail Clip - Attachment
                                                                   Power Supply - Mounted
                                       DIN Rail Mounting Power Supply
DIN Rail Unmounting - Power Supply
1. Push up, compressing the tension spring at the bottom of the DIN rail clip.
2. Once the top of the DIN rail clip is above the top of the DIN rail, lift the unit from the DIN rail.
DIN Rail Mounting - Chassis
The chassis can be mounted on a DIN rail (OS6865-DIN-MNT).
1. Attach two (2) flat brackets to front and rear of chassis side mount brackets using four (4) screws
   (M5X10mm) provided for each flat bracket.
2. Hook the top of the DIN rail clips over the top of the DIN rail.
3. Rotate assembly down and pull down on the DIN rail clip strap allowing bottom of DIN rail clip to hook on
   the bottom of the DIN rail.
4. Release the DIN rail clip strap, securing the assembly in place.
OmniSwitch 6865 Hardware Users Guide    October 2022                                                      page 1-17
Mounting the OmniSwitch 6865                                                      Getting Started and Installation
Warning. When mounted vertically, suitable for mounting on concrete or other non-combustible
surfaces only (as shown).
                                                                 Flat Brackets to Chassis
   Flat Bracket Assembly
                                      Attaching Brackets To Chassis
DIN Rail Unmounting - Chassis
1. Pull down on the DIN rail clip straps releasing the bottom of DIN rail clips.
2. Rotate the bottom of the assembly away from the DIN rail and lift the assembly off the DIN rail.
page 1-18                                                  OmniSwitch 6865 Hardware Users Guide     October 2022
Getting Started and Installation                                                Mounting the OmniSwitch 6865
         Mounted (Chassis Not
                                                            Completed Mounting Example
                                       DIN Rail Mounting Chassis Assembly
DNV Mounting Steps
     The OmniSwitch chassis can be mounted according to DNV standards. The parts required are contained in
     the OS6865-DNV-FRCK and OS6865-DNV-HRCK kits.
     • OS6865-DNV-FRCK (Full Rack) - (2) Side Rails, (2) Rear Brackets, (1) Support Bracket, (21)
         M4X8MM with DNV Power Supply Tray and Cover - (1) Power Supply Tray (182343-10), (1)
         Power Supply Cover, (1) Filler Bracket, (2) Slider Brackets, (6) M3X6MM (Flat), (4) M3X6MM
         (Round)
     • OS6865-DNV-HRCK (Half Rack) - (2) Front Brackets, (2) Side Rails, (2) Rear Brackets, (1) Front
         Chassis-to-Tray Bracket, (1) Rear Chassis-to-Tray Bracket, (8) M4X8MM, (8) M3X6MM, (8)
         M4X6MM with DNV Power Supply Tray and Cover - (1) Power Supply Tray (182343-10), (1)
OmniSwitch 6865 Hardware Users Guide     October 2022                                              page 1-19
Mounting the OmniSwitch 6865                                                     Getting Started and Installation
        Power Supply Cover, (1) Filler Bracket, (2) Slider Brackets, (6) M3X6MM (Flat), (4) M3X6MM
        (Round)
Full-rack Mounting
    1 Install the Side Rails, Rear Brackets, and Power Supply Tray.
                                                                                   Side Rail
                                                                                   (7)
                                                                                   M4X8MM
                                                                      Support
            Side Rail                                                 Bracket
            (7) M4X8MM
            Holes ‘A’                              Power Supply Tray                     Rear Brackets
                                                   (4) M4X8MM
                                      Rails and Power Supply Tray
    2 Install Power Supplies.
                                                   Thumb
                  Side Rails, Rear Brackets, and Power Supply Tray with Power Supplies
page 1-20                                                 OmniSwitch 6865 Hardware Users Guide     October 2022
Getting Started and Installation                                               Mounting the OmniSwitch 6865
     3 Install Power Supply Cover.
     Cover
     (4) M3X6MM
                                                 Slider Brackets
                                                 (2) M3X6MM
                                                 Filler Bracket
                                                 (2) M3X6MM
                                                                           Bottom View
                   Top
                               Power Supply Tray Cover (Power Supplies Not Shown)
     4 Final Assembly
                                                 Final Assembly
OmniSwitch 6865 Hardware Users Guide     October 2022                                             page 1-21
Mounting the OmniSwitch 6865                                                         Getting Started and Installation
Half-rack Mounting
1. Install / align front and rear chassis-to-tray brackets.
                                                                         Front Chassis-to-Tray Bracket
       Rear Chassis-to-Tray Bracket
                   Front Tray-to-chassis Bracket
                   (Aligns with Front Chassis-to-Tray Bracket (See Next
Required Brackets for Side Mount Power Supply Tray (Brackets may be factory-installed.)
page 1-22                                                     OmniSwitch 6865 Hardware Users Guide     October 2022
Getting Started and Installation                                                   Mounting the OmniSwitch 6865
2. Align the holes in the power supply tray and fasten the two parts into a single assembly using the
   attachment screws.
                                   (2) M4X8MM
                                                                               (4) M3X6
                                       Secure Power Supply Tray to Chassis
3. Install Front Brackets and Side Rails.
                                                                               Front Bracket
         Front Bracket
                                                                               (4) M4X6MM
         (4) M4X6MM
                                                                               Holes (3) ‘B’
         Holes ‘B’
                                                                                        Side Rail
                                                                                        (3)
                                                                                        M4X8MM
                   Side Rail
                   (3) M4X8MM
                   Holes ‘A’
                                                         Rear Brackets
                                            Attach Brackets and Rails
OmniSwitch 6865 Hardware Users Guide      October 2022                                                  page 1-23
Mounting the OmniSwitch 6865                                                   Getting Started and Installation
4. Install Power Supplies using thumb screws.
       Thumb Screws toward front (not
                  Side Rails, Rear Brackets, and Power Supply Tray with Power Supplies
5. Install Power Supply Cover.
     Cover
     (4) M3X6MM
                                            Slider Brackets
                                            (2) M3X6MM
                                            Filler Bracket
                                            (2)
                                                                           Bottom
                Top
                        Side Power Supply Tray Cover (Power Supplies Not Shown)
page 1-24                                               OmniSwitch 6865 Hardware Users Guide     October 2022
Getting Started and Installation                                  Additional DIN / Wall Mounting Examples
6. Final Assembly
                                               Final Assembly
Additional DIN / Wall Mounting Examples
This section provides images of additional mounting examples.
• Be sure that the wall section and wall attachment screws (not provided) have the required
   strength to easily support the chassis assembly, mounting brackets, and power supplies.
• For each mounting hole the use of screws long enough (i.e. 3.5mm X 25mm) to penetrate any
   soft surfaces, such as sheetrock or drywall, and securely attach to a hard surface such as a wall
   stud or plywood backing is recommended.
OmniSwitch 6865 Hardware Users Guide   October 2022                                             page 1-25
Additional DIN / Wall Mounting Examples                                        Getting Started and Installation
                                    OS6865-U12X/P16X DIN Rail Examples
page 1-26                                               OmniSwitch 6865 Hardware Users Guide     October 2022
Getting Started and Installation                                    Additional DIN / Wall Mounting Examples
                                   OS6865-U12X/P16X Wall Mount Examples
                                       OS6865-U28X DIN Mount Examples
OmniSwitch 6865 Hardware Users Guide     October 2022                                             page 1-27
Connections and Cabling                                                     Getting Started and Installation
                                 OS6865-U28X Wall Mount Examples
Connections and Cabling
Once the switch is properly installed, connect all network and management cables required for
network applications.
Network Cable Installation Warning
Never install exposed network cables outdoors. Install network cables per manufacturer
requirements.
For additional information on cabling for console, USB, and other connections, refer to the
OmniSwitch AOS Switch Management Guide.
Serial Connection to the Console Port
The console port provides a serial connection to the switch using an RJ45 connector and is
required when logging into the switch for the first time.
 Serial Connection Default Settings
 baud rate                               9600
 parity none                             none
 data bits (word size)                   8
page 1-28                                            OmniSwitch 6865 Hardware Users Guide     October 2022
Getting Started and Installation                                                   Connections and Cabling
 Serial Connection Default Settings
 stop bits                                       1
For information on modifying these settings, refer to the OmniSwitch AOS Switch Management
Guide.
Booting the Switch
The switch does not have a power on/power off switch. To boot a switch, plug a power cord into
the power supply unit and then plug the cord into an easily-accessible, properly grounded power
outlet.
(Do not use an extension cord.)
The switch will power on and boot automatically.
Connect any redundant power supply power cords and plug them into a power outlet as well.
System and Port LEDs
During the boot process, component LEDs will flash and change color, indicating different stages
of
the boot.
 System LEDs
 OK                      •     Solid Green: Normal operation
                         •     Solid Amber: Software error detected
                         •     Blinking Green: Diagnostics in progress
 VC                      •     Off: The switch is booting
                         •     Blinking Green: VC Master. Unit number identified by the number of
                               blinks. Pauses every 5 seconds.
                         •     Blinking Amber: VC Slave. Unit number identified by the number of
                               blinks. Pauses every 5 seconds.
 PS1                     •     Off: Power supply not present
                         •     Solid Green: Normal operation
                         •     Solid Amber: Power supply error detected
 PS2                     •     Off: Power supply not present
                         •     Solid Green: Normal operation
                         •     Solid Amber: Power supply error detected
 SFP/SFP+ Port LEDs
OmniSwitch 6865 Hardware Users Guide      October 2022                                           page 1-29
Connections and Cabling                                                          Getting Started and Installation
 SFP and SFP+             •   Off: No link or link down
 Ports                    •   Solid Green: Link up
                          •   Blinking Green: Link up with activity
                          •   Solid Amber: Link up (100M)
                          •   Blinking Amber: Link up with activity (100M)
 RJ45 (PoE) Ports         •   Off: No link or link down
                          •   Solid Green: Link up (no PoE)
                          •   Blinking Green: Link up (no PoE) with activity
                          •   Solid Amber: Link up (PoE devices connected)
                          •   Blinking Amber: Link up (PoE devices connected) with activity
Note. Be sure the boot process is complete before checking LED status. If LEDs indicate persist
errors, contact Alcatel-Lucent Customer Support.
Once the switch has completely booted, connect to the console port and log in to the switch’s
Command Line Interface (CLI) and configure basic information. For more information, refer to
“The First Login Session” on page 1-30.
The First Login Session
To complete the setup process, follow these steps during the first login session:
• Log in to the switch
• Unlock session types
• Change the login password
• Set the date and time
• Set optional system information
• Save changes
Important. Connect to the switch via the console port before initiating the first login session.
Logging In to the Switch
At the login and password prompts, use the switch’s default settings:
 Login:                               admin
 Password:                            switch
Note. A user account includes a login name, password, and user privileges. Privileges determine
whether the user has read or write access to the switch and which commands the user is autho-
rized to execute. For detailed information on setting up and modifying user accounts, refer to the
OmniSwitch Switch Management Guide.
The default welcome banner—which includes information such as the current software version
and system date—displays, followed by the CLI command prompt:
page 1-30                                                 OmniSwitch 6865 Hardware Users Guide     October 2022
Getting Started and Installation                                                       Connections and Cabling
Welcome to the Alcatel-Lucent Enterprise OS6865 8.3.1, June 03, 2016.
Copyright (c) 1994-2014 Alcatel-Lucent. All Rights Reserved.
Copyright (c) 2014-2016 Alcatel-Lucent Enterprise. All Rights Reserved.
OmniSwitch(tm) is a trademark of Alcatel-Lucent,
registered in the United States Patent and Trademark Office.
->
Unlocking Session Types
Remote session types (Telnet, FTP, WebView, SNMP) are restricted until they are manually
unlocked by
the user.
The CLI command used to unlock session types is aaa authentication.
Note. Unlocking session types grants switch access to non-local sessions (e.g., Telnet). As a
result, anyone with the correct user login and password will have remote access to the switch.
For more information on switch security, refer to the OmniSwitch AOS Switch Management
Guide.
Unlocking All Session Types
To unlock all session types, enter the following command syntax at the CLI prompt:
-> aaa authentication default local
Unlocking Specific Session Types
You can also unlock specific session types (console, telnet, ftp, http, snmp, ssh). For example, to
unlock Telnet sessions, enter the following command:
-> aaa authentication telnet local
Refer to the OmniSwitch CLI Reference Guide for complete aaa authentication command syntax
options.
Changing the Login Password
Change the login password for admin user sessions by following the steps below:
1. Be sure that you have logged into the switch as user type admin (see “Logging In to the Switch” on
   page 1-30).
2. Type password at the prompt and press Enter.
3. Enter the new password at the prompt.
OmniSwitch 6865 Hardware Users Guide   October 2022                                                  page 1-31
Connections and Cabling                                                          Getting Started and Installation
Note. Be sure to remember or securely record all new passwords; overriding configured pass-
words on an OmniSwitch is restricted.
4. You will be prompted to re-enter the password. Enter the password a second time.
New password settings are automatically saved in real time to the local user database; the user is
not required to enter an additional command in order to save the password information. Also note
that new password information is retained following a reboot. All subsequent login sessions,
including those through the console port, will require the new password to access the switch.
For detailed information on managing login information, including user names and passwords,
refer to the OmniSwitch Switch Management Guide.
Setting the System Time Zone
The switch’s default time zone is UTC. If you require a time zone that is specific to your region,
or if you need to enable Daylight Savings Time (DST) on the switch, you can configure these
settings via the system timezone and system daylight-savings-time commands.
For detailed information on configuring a time zone for the switch, refer to the OmniSwitch AOS
Switch Management Guide.
Setting the Date and Time
Set the current time for the switch by entering system time, followed by the current time in
hh:mm:ss.
To set the current date for the switch, enter system date, followed by the current date in mm/dd/
yyyy.
Setting Optional Parameters
Specifying an Administrative Contact
An administrative contact is the person or department in charge of the switch. If a contact is
specified, users can easily find the appropriate network administrator if they have questions or
comments about the switch.
To specify an administrative contact, use the system contact command.
Specifying a System Name
The system name is a simple, user-defined text description for the switch.
To specify a system name, use the system name command.
page 1-32                                                 OmniSwitch 6865 Hardware Users Guide     October 2022
                            2           Chassis and Power
OmniSwitch 6865-P16X
The Alcatel-Lucent Enterprise OmniSwitch® 6865 series are Gigabit Ethernet (GigE) and 10 Gb
Ethernet (GigE) switches designed for demanding electrical and severe temperature
environments.
                   OmniSwitch 6865-P16X (Side Mounted Power Supply Tray Shown)
 OmniSwitch 6865-P16X Chassis Specifications
 Fans                                           None
 Power Supplies                                 2 total (1 primary PSU and 1 optional backup PSU)
 Rack Unit Dimensions                           2 RU (Additional clearance is required for airflow,
                                                see “Providing Air Flow and Minimum Recommended
                                                Clearances” on page 2-17 for more information.)
 Dimensions (WxHxD)                             21.6 cm (8.5 in) x 8.81 cm (3.47 in) x 26 cm (10.24 in)
 Weight                                         5.07 kg (11.18 lb)
 Operating Temperature (TMRA)                   With airflow: -40°C to 74°C (-40°F to 165°F)
                                                Without airflow: -40°C to 65°C (-40°F to 149°F)
                                                With DNV Power Supply Cover (with or without airflow):
                                                -40°C to 55°C (-40°F to 131°F)
OmniSwitch 6865 Hardware Users Guide   October 2022                                                 page 2-1
OmniSwitch 6865-P16X                                                                     Chassis and Power
 OmniSwitch 6865-P16X Chassis Specifications
 Storage Temperature                       -40°C to 85°C (-40°F to 185°F)
 Operating and Storage Humidity            5% to 95% non-condensing
 Altitude                                  4000m/13,000 feet
 75W HPoE / 60W 802.3bt Ports              4
 30W PoE+ Ports                            8
 SFP Ports                                 2
 1G/10G SFP+ Ports                         2
 1588v2 Capability                         Supported
 PoE Power Budget                          See “Power over Ethernet Budget” on page 3-48 for more
                                           information.
 Power Consumption (idle)                  30W
page 2-2                                               OmniSwitch 6865 Hardware Users Guide   October 2022
Chassis and Power                                                                  OmniSwitch 6865-P16X
Chassis Front Panel
 Front Panel Descriptions (Left to Right)
 Console (RJ45)                    For console or modem
 USB Type A                        For storage devices that can download code or save configu-
                                   ration information, such as flash-based pen drives or external
                                   hard drives. For Maintenance Only.
 Ports 1 and 2                     Two (2) fixed SFP+ (1G/10G)
 Ports 3 and 4                     Two (2) 1000Base-X SFP
 Ports 5 through 8                 Four (4) 10/100/1000Base-T PoE+/802.3bt (supporting 75W
                                   HPoE / 60W 802.3bt per port)
 Ports 9 through 16                Eight (8) 10/100/1000Base-T PoE+ (supporting 30W PoE
                                   per port)
Note: For LED descriptions, refer to “System and Port LEDs” on page 2-43.
OmniSwitch 6865 Hardware Users Guide   October 2022                                             page 2-3
OmniSwitch 6865-U12X                                                                          Chassis and Power
Chassis Rear Panel
 Rear Panel Descriptions (Left to Right)
 PS2                                       Power Supply Connector
 PS1                                       Power Supply Connector
 Grounding Block                           Chassis Ground
OmniSwitch 6865-U12X
 OmniSwitch 6865-U12X Chassis Specifications
 Fans                                          None
 Power Supplies                                2 total (1 primary PSU and 1 optional backup PSU)
 Rack Unit Dimensions                          2 RU (Additional clearance is required for airflow,
                                               see “Providing Air Flow and Minimum Recommended
                                               Clearances” on page 2-17 for more information.)
 Dimensions (WxHxD)                            21.6 cm (8.5 in) x 8.81 cm (3.47 in) x 26 cm (10.24 in)
 Weight                                        5.17 kg (11.40 lb)
 Operating Temperature (TMRA)                  With airflow: -40°C to 74°C (-40°F to 165°F)
                                               Without airflow: -40°C to 65°C (-40°F to 149°F)
                                               With DNV Power Supply Cover (with or without airflow):
                                               -40°C to 55°C (-40°F to 131°F)
 Storage Temperature                           -40°C to 85°C (-40°F to 185°F)
 Operating and Storage Humidity                5% to 95% non-condensing
 Altitude                                      4000m/13,000 feet
 75W HPoE / 60W 802.3bt Ports                  4
page 2-4                                                    OmniSwitch 6865 Hardware Users Guide   October 2022
Chassis and Power                                                                    OmniSwitch 6865-U12X
 OmniSwitch 6865-U12X Chassis Specifications
 30W PoE+ Ports                                 0
 SFP Ports                                      6
 1G/10G SFP+ Ports                              2
 1588v2 Capability                              Supported
 PoE Power Budget                               See “Power over Ethernet Budget” on page 3-48 for more
                                                information.
 Power Consumption (idle)                       29W
Chassis Front Panel
 Front Panel Descriptions (Left to Right)
 Console (RJ45)                    For console or modem
 USB Type A                        For storage devices that can download code or save configu-
                                   ration information, such as flash-based pen drives or external
                                   hard drives. For Maintenance Only.
 Ports 1 and 2                     Two (2) fixed SFP+ (1G/10G)
 Ports 3 and 4                     Two (2) 1000Base-X SFP
 Ports 5 through 8                 Four (4) 100Base-FX/1000Base-X SFP
 Ports 9 through 12                Four (4) 10/100/1000Base-T PoE+/802.3bt (supporting 75W
                                   HPoE / 60W 802.3bt per port)
Note: For LED descriptions, refer to “System and Port LEDs” on page 2-43.
OmniSwitch 6865 Hardware Users Guide   October 2022                                               page 2-5
OmniSwitch 6865-U28X                                                                          Chassis and Power
Chassis Rear Panel
 Rear Panel Descriptions (Left to Right)
 PS2                                       Power Supply Connector
 PS1                                       Power Supply Connector
 Grounding Block                           Chassis Ground
OmniSwitch 6865-U28X
 OmniSwitch 6865-U28X Chassis Specifications
 Fans                                          None
 Power Supplies                                2 total (1 primary PSU and 1 optional backup PSU)
 Rack Unit Dimensions                          1 RU (Additional clearance is required for airflow,
                                               see “Providing Air Flow and Minimum Recommended
                                               Clearances” on page 2-17 for more information.)
 Dimensions (WxHxD)                            43.75 cm (17.2 in) x 4.4 cm (1.73 in) x 26.88 cm (10.6 in)
 Weight                                        6.28 kg (13.85 lb)
 Operating Temperature (TMRA)                  With airflow: -40°C to 74°C (-40°F to 165°F)
                                               Without airflow: -40°C to 65°C (-40°F to 149°F)
                                               With DNV Power Supply Cover (with or without airflow):
                                               -40°C to 55°C (-40°F to 131°F)
 Storage Temperature                           -40°C to 85°C (-40°F to 185°F)
 Operating and Storage Humidity                5% to 95% non-condensing
 Altitude                                      4000m/13,000 feet
 75W HPoE / 60W 802.3bt Ports                  4
page 2-6                                                    OmniSwitch 6865 Hardware Users Guide   October 2022
Chassis and Power                                                                    OmniSwitch 6865-U28X
 OmniSwitch 6865-U28X Chassis Specifications
 30W PoE+ Ports                                 0
 SFP Ports                                      20
 1G/10G SFP+ Ports                              4
 1588v2 Capability                              Supported
 PoE Power Budget                               See “Power over Ethernet Budget” on page 3-48 for more
                                                information.
 Power Consumption (idle)                       50W
Chassis Front Panel
 Front Panel Descriptions (Left to Right)
 Console (RJ45)                    For console or modem
 USB Type A                        For storage devices that can download code or save configu-
                                   ration information, such as flash-based pen drives or external
                                   hard drives. For Maintenance Only.
 Ports 1 through 4                 Four (4) fixed SFP+ (1G/10G)
 Ports 5 through 24                Twenty (20) 100Base-FX/1000Base-X SFP
 Ports 25 through 28               Four (4) 10/100/1000Base-T PoE+/802.3bt (supporting 75W
                                   HPoE / 60W 802.3bt per port)
Note: For LED descriptions, refer to “System and Port LEDs” on page 2-43.
OmniSwitch 6865 Hardware Users Guide   October 2022                                               page 2-7
Power Supplies                                                                                Chassis and Power
Chassis Rear Panel
 Rear Panel Descriptions (Left to Right)
 PS2                                       Power Supply Connector
 PS1                                       Power Supply Connector
 Grounding Block                           Chassis Ground
 Ports 29 and 30                           QSFP+ VFL Ports
Power Supplies
OS6865-BP - 180W AC Power Supply
                 Power Supply Front                                    Power Supply Rear
 OS6865-BP - 180W Power Supply
 Description                        Modular AC power supply. Up to two (2) power supplies may
                                    be installed.
 Dimensions (H x W x L)             5.1 cm x 9.5 cm x 18.1 cm (2 in x 3.74 in x7.12 in)
 Weight                             1.36 kg (3.00 lbs)
 Input Voltage / Current / Hz       100 VAC to 240 VAC / 3 A - 1.5 A / 50-60 Hz
 Output Voltage / Current           +56 VDC / 3.22 A
 Fans                               0
 Front-of-Supply Component Descriptions (Left to Right)
 Power Cord Connector
page 2-8                                                    OmniSwitch 6865 Hardware Users Guide   October 2022
Chassis and Power                                                                            Power Supplies
 Front-of-Supply Component Descriptions (Left to Right)
 Thumb Screw
 Grounding Block                            Power Supply Ground
 Status LED                                 Solid Green indicates normal operation
 Rear-of-Supply Component Descriptions
 DB-15 Connector (with Guide Pins)
OS6865-BP-D - 180W/140W DC Power Supply
                    Power Supply Front                                Power Supply Rear
 OS6865-BP-D 180W/140W DC Power Supply
 Description                           Modular DC power supply. Up to two (2) power supplies may
                                       be installed.
 Dimensions (H x W x L)                5.1 cm x 9.5 cm x 18.1 cm (2 in x 3.74 in x7.12 in)
 Weight                                1.44 kg (3.17 lbs)
 Input Voltage / Current               -20 VDC to -28 VDC / 12A
                                       -36 VDC to -72 VDC/ 6A
 Output Voltage / Current              -56V/2.5A (140W)
                                       -56V/3.22A (180W)
 Fans                                  0
 Front-of-Supply Component Descriptions (Left to Right)
 DC Power Connector                         See “DC Power Supply Connection” on page 2-10
 Thumb Screw
OmniSwitch 6865 Hardware Users Guide   October 2022                                                page 2-9
DC Power Supply Connection                                                                         Chassis and Power
    Front-of-Supply Component Descriptions (Left to Right)
    Grounding Block                               Power Supply Ground
    Status LED                                    Solid Green indicates normal operation
    Rear-of-Supply Component Descriptions
    DB-15 Connector (with Guide Pins)
DC Power Supply Connection
Connecting a DC Cable Harness to the Chassis Power Supply
When plugging in the cable, insert the connector end of the cable harness into the power supply
connector until it clicks firmly into place. This is an indication that the connector is secure and
properly seated. Secure the screws.
Connecting a DC Cable Harness to the DC Power Source
The other end of the cable harness is bare. Users must assemble and connect this end to the DC
power source or to a cable coming from the power source. In addition to following the important
guidelines listed below, be sure to consult manufacturer specifications for the DC power source
before starting.
• Connect the power supply to a reliably grounded -24V or -48V DC SELV source.
•     Use common DC return connections for the DC power supplies. The DC return terminal
      conductor should be connected to the equipment frame.
•     The branch circuit overcurrent protection must be rated 15A.
•     Use two 12 AWG copper conductors.
•     A readily accessible disconnect device that is suitably approved and rated shall be
      incorporated in the field wiring.
CAUTION: Installation of a DC cable that is more than 3 meters in length is subject to LOCAL
CODES and AUTHORITIES. Please contact your electrician and the Local AHJ (Authority Hav-
ing Jurisdiction) to follow the Electrical Codes before use of proper installation methods.
            Black
                         MIN 1 TURN PER 1.5
                  HALF TURN PER .75
            Red
                                  Twisted pair wire (red and black) for a DC power supply
page 2-10                                                        OmniSwitch 6865 Hardware Users Guide   October 2022
Chassis and Power                                                                            DC Power Supply Connection
Connecting a DC Power Source
The DC power supply contains a power connector with three (3) square slots for connecting the
positive, negative, and ground wires from a DC power source.
                                                        +   -
                                       Side Screws for Connector Removal
                                 OmniSwitch DC Power Supply Connector
A clamp inside each slot keeps the power wire tightly in place during operation. The DC power
supply connector has side screws that can be used to remove the connector if required.
Installing DC Power Source Wire Leads
These instructions describe how to connect your 3-wire DC power source to the power connector
on your DC power supply. A small flat-tip screwdriver and a wire stripper are required for this
procedure.
1. Prepare the three (3) wires—12 gauge—that will plug into the power supply. First make sure they are not
   plugged into the DC power source. Next, use a wire stripper to carefully strip between .24 and .30 inches
   (6-7.5 mm) off the end of each wire, removing the outer insulation to expose the copper core.
2. Open the clamp for the ground wire slot by inserting a small flat-tip screwdriver into the top of the appro-
   priate circular hole. Loosen the screw so that the clamp for the ground wire opens.
                                                Loosen Screw.
                                               +    -
                                                            Clamp inside square hole will open
                                                            when screw is loosened in top cir-
                                                            cular hole.
                                       Opening Connector for Ground Wire
3. Insert the ground wire lead into the slot. The lead you insert must match the lead attached to the DC power
   source. Push the wire in far enough such that it reaches the back wall of the connector, about a half inch
   inside.
    Warning. You must plug DC wire leads into the correct holes in the DC power connector. Use the labels
    above the DC power connector as a guide to positive, negative, and ground connections. If the wire leads
    are plugged into the wrong holes, the power supply will not work properly and damage to the unit may
    result.
OmniSwitch 6865 Hardware Users Guide     October 2022                                                         page 2-11
Dying Gasp                                                                                    Chassis and Power
                                +-
                                                                         Ground Wire
                                           Attaching the Ground Wire
4. Tighten the clamp by tightening the screw above the slot into which you inserted the wire lead. The wire
   lead should be securely attached inside the connector. You should be able to pull on the wire and not dis-
   lodge it.
    Warning. For both -24V and -48V input voltages, the positive (+) wire of the sourcing equipment, such as
    a battery or rectifier, must be connected to the positive (+) terminal of the DC power supply and the nega-
    tive (-) wire of the sourcing equipment must be connected to the negative (-) terminal of the DC power
    supply. This rule always applies to both -24V, and -48V input voltages, regardless of the polarity signs
    shown on the power supply specification labels such as: -48V, +24V, or -24V."
5. Repeat Steps 2 through 4 for the remaining positive and negative wire leads.
                    Switch Power Supply
                                                                 DC Power Source
                                          Correct Polarity Connections
Dying Gasp
If the switch loses all power it will maintain power long enough to send a Dying Gasp message
before completely shutting down. An SNMP trap, Syslog message and Link OAM PDUs will be
generated.
page 2-12                                                   OmniSwitch 6865 Hardware Users Guide   October 2022
Chassis and Power                                                                         Dying Gasp
Scenarios
A Dying Gasp event will be generated in the following scenarios:
• Primary power supply failure (if only power supply present)
• Primary power supply failure and then backup power supply failure
• Backup power supply failure and then primary power supply failure
Connect each power supply to a separate independent power source to avoid simultaneous
power failures.
SNMP Trap
As soon as the power failure is detected, an SNMP trap is sent to the first three configured SNMP
stations. The trap includes the following information:
• Slot number
• Power supply type (primary/backup)
• Time of the failure
Use the snmp station command and refer to the SNMP Configuration chapter for information on
configuring an SNMP station.
Syslog Message
As soon as the power failure is detected, the following Syslog message is sent to the first three
configured Syslog servers, along with the time of the failure:
Dying Gasp Power Failure Event Occurred
Use the swlog output socket command to add a Syslog station. Refer to the Using Switch Log-
ging
Configuration chapter in the Network Configuration Guide for information on configuring a Sys-
log server.
Link OAM PDU
As soon as the power failure is detected four 802.3ah OAM Information PDUs are sent to ports
for which link OAM is enabled and the LinkOAM port status is operational. The PDU will have
the Dying Gasp bit set.
Use the efm-oam and efm-oam port propagate-events commands to enable the generation of an
802.3ah OAM Information PDU upon a dying gasp event:
-> efm-oam admin-state enable
-> efm-oam port 1/1/23-34 admin-state enable
-> efm-oam port 1/1/23-24 propagate-events dying-gasp enable
OmniSwitch 6865 Hardware Users Guide   October 2022                                         page 2-13
Dying Gasp                                                                           Chassis and Power
Link OAM PDU Priority
It may not be possible to generate PDUs on all ports enabled for link OAM. Dying gasp packets
will be sent in the following order based on port priority:
1. Uplink ports
2. All other ports
Note: The maximum number ports which can send out a dying gasp PDU simultaneously is lim-
ited to ten ports minus the number of syslog/snmp servers configured. For example, if two snmp
servers and one syslog server are configured, the maximum number of ports which can send out a
dying gasp PDU is seven.
page 2-14                                          OmniSwitch 6865 Hardware Users Guide   October 2022
3           Power Over Ethernet (PoE)
Managing Power over Ethernet (PoE)
Important: It’s recommended that PoE-enabled switches with attached IP telephones have opera-
tional power supply redundancy at all times for 911 emergency requirements. In addition, both the
switch and the power supply should be plugged into an Uninterruptible Power Source (UPS).
 Power over Ethernet Specifications
 IEEE Standards supported              IEEE 802.3; 802.af; 802.3at
 Power over Ethernet Settings          Default                          Related Command
 PoE operational status                Disabled                         lanpower slot service
 Total power available to a port       75000 milliwatts (HPoE Ports)    lanpower power
                                       60000 milliwatts (802.3bt)
                                       30000 milliwatts (PoE Ports)
 Total power available to an                                            lanpower slot maxpower
 entire slot
 Power priority level for a port       low                              lanpower priority
 Capacitor detection method            Disabled                         lanpower capacitor-detection
 Priority disconnect status            Enabled                          lanpower slot priority-disconnect
Power over Ethernet Budget
The following tables list the Power over Ethernet wattages available based on the number and
types of power supplies installed and the ambient temperature.
 Operating Temperature (TMRA)/                    60°C                 65°C                74°C
 Power Supply                                     (without airflow)    (without airflow)   (with airflow)
 (1) OS6865-BP-D @ 48V                            140W                 140W                120W
 (2) OS6865-BP-D @ 48V                            300W                 150W                150W
 (1) OS6865-BP-D @ 24V                            100W                 100W                80W
 (2) OS6865-BP-D @ 24V                            240W                 150W                150W
 (1) OS6865-BP                                    140W                 140W                140W
OmniSwitch 6865 Hardware Users Guide   October 2022                                                   page 3-1
Managing Power over Ethernet (PoE)                                               Power Over Ethernet (PoE)
 (2) OS6865-BP                               300W                150W                 150W
 (1) OS6865-BP and (1) OS6865-BP-D @ 48V     300W                150W                 150W
 (1) OS6865-BP and (1) OS6865-BP-D @ 24V     240W                150W                 150W
                   OmniSwitch 6865-P16X / U12X PoE Budget and Temperature Table
 Operating Temperature (TMRA)/               60°C                65°C                 74°C
 Power Supply                                (without airflow)   (without airflow)    (with airflow)
 (1) OS6865-BP-D @ 48V                       100W                100W                 100W
 (2) OS6865-BP-D @ 48V                       280W                150W                 150W
 (1) OS6865-BP-D @ 24V                       80W                 80W                  80W
 (2) OS6865-BP-D @ 24V                       200W                150W                 150W
 (1) OS6865-BP                               100W                100W                 100W
 (2) OS6865-BP                               280W                150W                 150W
 (1) OS6865-BP and (1) OS6865-BP-D @ 48V     280W                150W                 150W
 (1) OS6865-BP and (1) OS6865-BP-D @ 24V     200W                150W                 150W
                         OmniSwitch 6865-U28X PoE Budget / Temperature Table
Determining the Power Available for Powered Devices (PDs)
Viewing Power Supply Status
To view the type and status for installed power supplies, use the show powersupply command.
Viewing PoE Status
To view current PoE status and settings, uncluding the amount of PoE power available for
incoming powered devices, use the show lanpower slot command.
PoE Class Detection
Powered devices can be classified into different classes as shown in the table below. Class
detection allows for automatic maximum power adjustment based on the power class detected.
This will prevent the switch from delivering more than the maximum power allowed based on a
device’s class.
page 3-2                                               OmniSwitch 6865 Hardware Users Guide   October 2022
Power Over Ethernet (PoE)                                                 Managing Power over Ethernet (PoE)
During class detection, the switch will allocate the maximum amount of power allowed based on
the class detected. Once powered, if the device uses less than the maximum, the remaining power
will be made available for other devices.
 Class                  Usage                  Current (mA)   Power Range             Class Description
                        Classification                        (Watts)
          0             Default                0-4            0.44-30.00              Unimplemented
          1             Optional               9-12           0.44-3.84               Very Low Power
          2             Optional               17-20          3.84-6.49               Low Power
          3             Optional               26-30          6.49-12.95              Mid Power
          4             Optional               36-44          12.95-30.00             High Power
Although class-detection is disabled by default, power is still provided to incoming PDs (if
available in the power budget). However, to strictly enforce class detection as specified in the
802.3at standard, class detection must be enabled using the lanpower slot class-detection
command.
Enabling class detection will reset all PoE ports.
PoE Operational Status
Enabling PoE
By default, PoE is administratively enabled in the switch’s system software. However, in order to
physically activate PoE, you must issue the lanpower slot service command on a slot-by-slot
basis before any connected devices will receive inline power.
To activate power to PoE-capable in a switch, enter the corresponding slot number only. For
example:
-> lanpower slot 2/1 service start
If power to a particular port has been administratively disconnected, you can reactivate power to
the port using the lanpower port admin-state command. For example:
-> lanpower port 1/1/1-16 admin-state enable
Note. You cannot use the lanpower port admin-state command to initially activate PoE on a
port. This syntax is intended only to reactivate power to those that have been disconnected via the
lanpower slot service command. To initially activate PoE, you must use the lanpower slot ser-
vice command as described above.
OmniSwitch 6865 Hardware Users Guide     October 2022                                               page 3-3
Managing Power over Ethernet (PoE)                                            Power Over Ethernet (PoE)
Disabling PoE
To disable PoE on a particular port, use the lanpower port admin-state command. For example:
-> lanpower port 1/1/12 admin-state disable
To disable PoE for all PoE-capable ports in a slot, use the lanpower slot service command. For
example:
-> lanpower slot 1/1 service stop
Fast PoE
Fast PoE can be used to provide PoE power within a few seconds after powering on the chassis.
Prior to this feature PoE power was not provided until the chassis had completed boot-up. With
Fast PoE the default state of the PoE subsystem is set to enabled in the FPGA image and the PoE
configuration is stored in the controller EEPROM. This allows the chassis to immediately provide
PoE power to any connected devices immediately after being powered on without waiting for the
chassis to complete the boot-up process.
• Fast PoE requires the proper FPGA/CPLD version, refer to the release notes for additional
    information.
• Factory default switches that don't have any PoE configuration must have an initial PoE con-
    figuration completed.
• The PoE configuration cannot be modified until the switch is up and the PoE software module
    is completely initialized.
• LLDP-based PoE devices will not function as expected until the switch has completed the
    boot-up process and the switch is in a state to respond to LLDP requests.
To enable Fast PoE, use the lanpower slot fpoe command. For example:
-> lanpower slot 1/1 fpoe enable
Perpetual PoE
Perpetual PoE allows the switch to provide uninterrupted power to connected power devices (PD)
even when the switch is rebooting or reloading, such as on a soft reset.
• Perpetual PoE requires the proper FPGA/CPLD version, refer to the release notes for addi-
   tional information.
• The power to the PD devices will be interrupted if the PoE controller (MCU) firmware itself is
   being upgraded.
To enable Perpetual PoE, use the lanpower slot ppoe command. For example:
-> lanpower slot 1/1 ppoe enable
Configuring the Total Power Available to a Port
By default, each port is authorized by the system software to use up to a maximum amount of
milliwatts to power any attached device.
page 3-4                                            OmniSwitch 6865 Hardware Users Guide   October 2022
Power Over Ethernet (PoE)                                             Managing Power over Ethernet (PoE)
This value can be increased or decreased based on the allowed ranges.
Increasing the total power available to an individual port may provide a more demanding
powered device with additional power required for operation. Decreasing the total power
available to a port helps to preserve inline power and assists in the overall management of the
switch’s power budget.
To increase or decrease the total power available to an individual port, use the lanpower power
command.
Note. Since the power allowance is being set for an individual port, chassis/slot/port values must
be specified.
Configuring the Total Power Available to a Slot
Like the maximum port power allowance, the system software also provides a maximum slot-
wide power allowance. By default, each slot is authorized by the system software to use a number
of watts to power all devices connected to its ports depending on which power supply is used.
As with the maximum port power allowance, the user can either increase or decrease this value
based on the allowed ranges.
Note. Decreasing the slot-wide power could cause lower priority ports to lose power if the new
value is less than the total PoE power currently being consumed.
To increase or decrease the total power available to a slot, use the lanpower slot maxpower
command.
Since you are setting the power allowance for an individual slot, you must specify a chassis/slot
value in
the command line. For example, the syntax
-> lanpower slot 1/1 maxpower 150
reduces the power allowance of chassis 1, slot 1 to 150 watts. This value is now the maximum
amount of
power the slot can use to power all attached devices (until the value is modified by the user).
Note. Changing the maximum power available to a slot or port does not reserve or immediately
allocate that power. These settings are only used for configuring a maximum amount of power
that may be used, any unused power is still available and remains a part of the overall PoE budget.
OmniSwitch 6865 Hardware Users Guide   October 2022                                             page 3-5
Managing Power over Ethernet (PoE)                                               Power Over Ethernet (PoE)
Setting Timers and Other User-Defined PoE Power Rules
The lanpower power-rule command allows user to set additional rules for PoE power (e.g.,
setting PoE to turn on or off on specific dates or at specific times). Refer to the OmniSwitch AOS
CLI Command Reference Guide for more information.
Setting Port Priority Levels
As not all Powered Devices (PDs) connected to the switch have the same priority within a
network setting, the OmniSwitch allows the administrator to specify priority levels on a port-by-
port basis. Priority levels include low, high, and critical.
The default priority level for a port is low.
•   Low. This default value is used for port(s) that have low-priority devices attached. In the
    event of a power management issue, inline power to low-priority is interrupted first (i.e.,
    before critical and high priority).
•   High. This value is used for port(s) that have important, but not mission-critical, devices
    attached. If other ports in the chassis have been configured as critical, inline power to high-
    priority is given second priority.
•   Critical. This value is used for port(s) that have mission-critical devices attached, and
    therefore require top (i.e., critical) priority. In the event of a power management issue, inline
    power to critical is maintained as long as possible.
To change the priority level for a particular port, use the lanpower priority command. Since the
switch
allows you to set priority levels on a port-by-port basis, be sure to specify chassis/slot/port
information in the command line. For example, the syntax
-> lanpower port 1/1/6 priority critical
changes the priority value of port 6 to the highest priority level of critical. Now that the default
value has been reconfigured, this port should be reserved for those PDs that are mission critical
for network operations.
Setting the Capacitor Detection Method
By default, the capacitor detection method is disabled. To enable it, use the lanpower capacitor-
detection command. For example:
-> lanpower slot 1/1 capacitor-detection enable
Note. The capacitive detection method should only be enabled to support legacy IP phones. This
feature is not compatible with IEEE specifications. Please contact your Alcatel-Lucent sales engi-
neer or Customer Support representative to find out which Alcatel-Lucent IP phones models need
capacitive detection enabled.
page 3-6                                               OmniSwitch 6865 Hardware Users Guide   October 2022
Power Over Ethernet (PoE)                                               Managing Power over Ethernet (PoE)
Understanding Priority Disconnect
Priority disconnect is used by the system software in determining whether an incoming PD will
be granted or denied power when there are too few watts remaining in the PoE power budget for
an additional device. For example, if there are only 2 watts available in the current PoE power
budget and a user plugs a 3.5W powered device into a PoE port, the system software must
determine whether the device will be powered on.
Based on priority disconnect rules, in some cases one or more existing devices may be powered
down in order to accommodate the incoming device. In other cases, the incoming device will be
denied power.
Priority disconnect rules involve the port priority status of an incoming device (i.e., low, high, and
critical), as well as the port’s physical port number. Understanding priority disconnect rules is
especially helpful in avoiding power budget deficits and the unintentional shutdown of mission-
critical
devices when PDs are being added in tight power budget conditions.
         Reminder. Priority disconnect applies only when there is inadequate power
         remaining in the power budget for an incoming device.
For information on setting the priority disconnect status, refer to the section below. For
information on setting the port priority status (a separate function from priority disconnect), refer
to “Setting Port Priority Levels” on page 3-6.
Setting Priority Disconnect Status
By default, priority disconnect is enabled in the switch’s system software. For information on
changing the priority disconnect status, refer to the information below.
Disabling Priority Disconnect
When priority disconnect is disabled and there is inadequate power in the budget for an additional
device, power will be denied to any incoming PD, regardless of its port priority status (i.e., low,
high, and critical) or physical port number.
To disable priority disconnect, use the lanpower slot priority-disconnect command. For example:
-> lanpower slot 1/1 priority-disconnect disable
Enabling Priority Disconnect
To enable priority disconnect, use the lanpower slot priority-disconnect command. For example:
-> lanpower slot 1/1 priority-disconnect enable
OmniSwitch 6865 Hardware Users Guide   October 2022                                               page 3-7
Managing Power over Ethernet (PoE)                                                  Power Over Ethernet (PoE)
Priority Disconnect is Enabled; Same Priority Level on All Devices
           Reminder. Priority disconnect examples are applicable only when there is
           inadequate power remaining to power an incoming device.
When a PD is being connected to a port with the same priority level as all other in the slot, the
physical
port number is used to determine whether the incoming PD will be granted or denied power. Due
to the
support of different PoE standards and PoE hardware on each platform the internal port priority is
different for each platform. The following tables should be used to determine PoE priority:
 PoE Physical Port Priority
 1 (Highest) -> 28 (Lowest)
Priority Disconnect is Enabled; Incoming PD Port has Highest Priority Level
           Reminder. Priority disconnect examples are applicable only when there is
           inadequate power remaining to power an incoming device.
When a PD is being connected to a port with a higher priority level than all other in the slot, the
incoming PD will automatically be granted power over the other devices, regardless of its
physical port number.
In order to avoid a power budget deficit, another port in the slot is disconnected. In determining
which
port to power off, the system software first selects the port with the lowest configured priority
level. For example, if a critical priority device is being added to a slot in which five existing
devices are attached to high priority and one device is attached to a low priority port, the low
priority port is automatically disconnected, regardless of its physical port number.
If all existing devices are attached to with the same lower priority level, the system software
disconnects the port with both the lowest priority level. For example, if a critical priority device is
being added to a slot in which six existing devices are attached at high priority, the high priority
port with the highest physical port number is automatically disconnected.
Priority Disconnect is Enabled; Incoming PD Port has Lowest Priority Level
           Reminder. Priority disconnect examples are applicable only when there is
           inadequate power remaining to power an incoming device.
When a PD is being connected to a port with a lower priority level than all other in the slot, the
incoming PD will be denied power, regardless of its physical port number. Devices connected to
other higher-priority will continue operating without interruption.
page 3-8                                                  OmniSwitch 6865 Hardware Users Guide   October 2022
Power Over Ethernet (PoE)                                                Managing Power over Ethernet (PoE)
Priority Disconnect is Disabled
         Reminder. Priority disconnect examples are applicable only when there is
         inadequate power remaining to power an incoming device.
When priority disconnect is disabled, power will be denied to any incoming PD, regardless of its
port
priority status (i.e., low, high, and critical) or physical port number.
Understanding Guard Band
Guard Band functionality is implemented when the switch has to provide power to a newly
connected PD. This functionality is more relevant on switches that have a lower amount of total
PoE power available for the switch but a higher default maximum PoE power available to some
ports.
•   If the amount of power remaining is less than the port's configured maximum PoE power
    value or the PD's class maximum power then the switch will not power up the PD.
•   This applies even if the newly connected PD actually requires less than the maximum power
    available for the port.
For example, assume the following:
• There is 50W of PoE power remaining on the switch.
• A newly connected PD only requires 4W of power.
• The port's maximum PoE power value is 75W.
In this example the newly connected PD will not be powered on since the port's maximum PoE
power value is greater than the PoE power remaining on the switch.
To allow the PD to be powered, the port's maximum PoE value can be configured to be less than
the power remaining by issuing the following command to set the port's maximum PoE power to
10W:
-> lanpower power 1/1/1 power 10000
Using the previous example:
• There is 50W of PoE power remaining on the switch.
• A newly connected PD only requires 4W of power.
• The port's maximum PoE power value is now 10W.
The newly connected PD will be powered on since the port's maximum PoE power value is now
less than the PoE power remaining on the switch.
The examples assume the new PD has the same or lower priority as the existing PDs, otherwise
priority disconnect will override.
The Guard Band functionality does not apply to PDs that are already powered up. However,
priority disconnect will apply if there's not enough power to power all PDs in the case of the
power budget being reduced, such as the removal of a power supply.
OmniSwitch 6865 Hardware Users Guide   October 2022                                                page 3-9
Managing Power over Ethernet (PoE)                                                 Power Over Ethernet (PoE)
Please refer to the “Understanding Priority Disconnect” on page 3-7 for additional details.
page 3-10                                                OmniSwitch 6865 Hardware Users Guide   October 2022
              A Regulatory Compliance and
                        Safety Information
    This appendix provides information on regulatory agency compliance and safety for the OmniSwitch.
Declaration of Conformity: CE Mark
    This equipment is in compliance with the essential requirements and other provisions of
    Directive 2014/30/EU (EMC), 2014/35/EU (LVD), 2011/65/EU (RoHS-Directive), 91/263/EEC (Tele-
    com Terminal Equipment, if applicable), 2014/53/EU (R&TTE, if applicable).
    Français: Cet équipement est conforme aux exigences essentielles et aux autres provisions de la Directive
    2014/30/EU (EMC), 2014/35/EU (LVD), 2011/65/EU (RoHS-Directive), 91/263/CEE (équipements
    terminaux de télécommunications, le cas échéant), 2014/53/EU (R&TTE, le cas échéant).
    Deutsch: Diese Ausrüstung erfüllt die wesentlichen Anforderungen und sonstigen Bestimmungen der
    Richtlinien 2014/30/EU (EMV-Richtlinie), 2014/35/EU (Niederspannungsrichtlinie), 2011/65/EU (RoHS-
    Directive), 91/263/EEC (Telekommunikationsendeinrichtungen, falls zutreffend), 2014/53/EU (Funkanla-
    gen und Telekommunikationsendeinrichtungen, falls zutreffend).
    Español: Este equipo cumple los requisitos esenciales y otras disposiciones de las directivas 2014/30/EU
    (EMC), 2014/35/EU (LVD), 2011/65/EU (RoHS-Directive), 91/263/CEE (equipos terminales de teleco-
    municación, si procede), 2014/53/EU (R&TTE, si procede).
Compliance and Certifications
Safety Standards
    • US UL 60950-1
    • US UL 62368-1
    • IEC 60950-1 Health and Safety
    • IEC 62368-1 Audio/Video, Information Technology: Safety requirement
    • CAN/CSA-C22.2 No. 60950-1
    • CAN/CSA-C22.2 No. 62638-1
    • EN 62368-1
    • NOM-019 SCFI, Mexico
OmniSwitch 6865 Hardware Users Guide   October 2022                                                    page -1
Compliance and Certifications
    • AS/NZ TS-001 and 60950:2000, Australia
    • UL-AR, Argentina
    • UL-GS Mark, Germany
    • CU, EAC, Russia
    • EN 60825-1 Laser
    • EN 60825-2 Laser
    • CDRH Laser
    • IEC 60950-1/EN 60950 with all country deviations
    • IEC 62368-1/EN 62368-1 with all country deviations
    • CCC, China*
    • ANATEL, Brazil (Contact for availability)
    • BSMI, Taiwan (Contact for availability)
    • KCC, Korea (Contact for availability)
    • TEC, India (Contact for availability)
    • Morocco (Contact for availability)
EMI/EMC Standards
    • FCC Part 15:2012, Subpart B, Class A
    • ICES–003:2012 Issue 5, Class A
    • ANSI C63.4-2009
    • FCC CRF Title 47 Subpart B (Class A)
    • VCCI (Class A)
    • AS/NZS 3548 (Class A)
    • CE marking for European countries (Class A)
    • EN 55032 (EMI & EMC)
    • EN 61000-3-2
    • EN 61000-3-3
    • EN 55024 (Immunity)/EN 55035 (Immunity)
    • EN 61000-4-2
    • EN 61000-4-3
    • EN 61000-4-4
    • EN 61000-4-5
page -2                                                  OmniSwitch 6865 Hardware Users Guide   October 2022
                                                                             Compliance and Certifications
    • EN 61000-4-6
    • EN 61000-4-8
    • EN 61000-4-11
    • IEEE 802.3: Hi-Pot Test
       (2250 V DC on all Ethernet ports)
    Environmental Standards
       • ETS 300 019 Storage Class 1.1
       • ETS 300 019 Transportation Class 2.3
          ETS 300 019 Stationary Use Class 3.1
Industrial Compliance Requirements
 Industrial Compliance Requirements
 Safety               ISA 12.12.01 (UL 1604), CSA22.2/213, UL 508, EN50021
 Operational          IEC 60870-2-2 (operational temperature)
 Temperature          IEC 60068-2-1 (temperature type test - cold)
                      IEC 60068-2-2 (temperature type test - hot)
 Storage              IEC 60721-3-1: Class 1K5 (storage temperature)
 Temperature
 Humidity             IEC 60068-2-30: 5% to 95% non-condensing humidity
 Mechanical           IEC 60255-21-2 (mechanical shock)
 Shock
 Vibration            IEC 60255-21-1 (vibration)
 Drop Test            IEC 60870-2-2 Free Fall
 Altitude Test        IEC 60870-2-2, GR-63-CORE, 4.1.3, 4.5
 IPX                  IPXX, IEC60529
OmniSwitch 6865 Hardware Users Guide   October 2022                                                page -3
Compliance and Certifications
 EMI/EMC                IEC 61000-6-2 (Immunity)
                        EN 61000-6-4 (Emmission)
                        EN 55032,
                        EN 61000-3-3
                        EN 61000-3-2
                        EN 55024
                        IEC 61850-3
                        EN 61000-4-2 to EN 61000-4-6,
                        EN 61000-4-8
                        EN 61131-2
                        IEEE 1613, Section 5.2, 5.3, 6.3.1, 6.3.2, 7, 8
 DNV                    DNV 2.4
 Railway                EN 50121-4
                        IEC 62236-4
                        EN 61000-6-4
 NEMA                   NEMA TS-2
page -4                                                         OmniSwitch 6865 Hardware Users Guide   October 2022
                                                      Compliance and Certifications
China RoHS: Hazardous Substance Table
OmniSwitch 6865 Hardware Users Guide   October 2022                         page -5
Compliance and Certifications
Taiwan RoHS: Hazardous Substance Table
California Proposition 65 Warning
WARNING: This product can expose you to chemicals including Pb and Pb compounds, which is
known to the State of California to cause cancer and birth defects or other reproductive harm. For
more information go to www.P65Warnings.ca.gov.
Products are packaged using one or more of the following packaging materials:
                  CB                          FB
          Corrugated Cardboard      Corrugated Fiberboard           Low-Density Polyethylene
page -6                                              OmniSwitch 6865 Hardware Users Guide   October 2022
                                                                            Compliance and Certifications
Waste Electrical and Electronic Equipment (WEEE) Statement
The product at end of life is subject to separate collection and treatment in the EU Member States,
Norway and Switzerland, and is therefore marked with the symbol:
Treatment applied at end of life of the product in these countries shall comply with the applicable
national laws implementing directive 2002/96EC on Waste Electrical and Electronic Equipment
(WEEE).
FCC Class A, Part 15
This equipment has been tested and found to comply with the limits for Class A digital device
pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions in this guide, may cause interference to radio communications.
Operation of this equipment in a residential area is likely to cause interference, in which case the
user will be required to correct the interference at his own expense.
The user is cautioned that changes and modifications made to the equipment without approval of
the
manufacturer could void the user’s authority to operate this equipment.It is suggested that the user
use
only shielded and grounded cables to ensure compliance with FCC Rules.
If this equipment does cause interference to radio or television reception, the user is encouraged
to try to correct the interference by one or more of the following measures:
• Reorient the receiving antenna.
• Relocate the equipment with respect to the receiver.
• Move the equipment away from the receiver.
• Plug the equipment into a different outlet so that equipment and receiver are on different
     branch circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for
additional suggestions.
OmniSwitch 6865 Hardware Users Guide   October 2022                                               page -7
Compliance and Certifications
Canada Class A Statement
This equipment does not exceed Class A limits per radio noise emissions for digital apparatus, set
out in
the Radio Interference Regulation of the Canadian Department of Communications.
Avis de conformitè aux normes du ministère des Communications du
Canada
Cet èquipement ne dèpasse pas les limites de Classe A d íèmission de bruits radioèlectriques pour
les appareils numèriques,telles que prescrites par le RÈglement sur le brouillage radioèlectrique
ètabli par le ministère des Communications du Canada.
JATE
This equipment meets the requirements of the Japan Approvals Institute of Telecommunications
Equipment (JATE).
CISPR22 Class A Warning
This is a Class A product. In a domestic environment, this product may cause radio interference.
Under such circumstances, the user may be requested to take appropriate countermeasures.
Korea Emissions Statement
      A 급 기기 ( 업무용 방송통신 기자재 )
                                                    Class A Equipment (Business equipment)
      이 기기는 업무용 (A 급 ) 전자파적합기기로서 판                  This equipment is registered for Electromagnetic
                                                    Conformity Registration as business equipment (A),
      매자 또는 사용자는 이 점을 주의하시기 바라
                                                    not home equipment. Sellers or users are required to
      며 , 가정외의 지역에서 사용하는 것을 목적으                     take caution in this regard.
      로 합니다.
VCCI
This is a Class A product based on the standard of the Voluntary Control Council for Interference
by Information Technology Equipment (VCCI). If this equipment is used in a domestic
environment, radio disturbance may arise. When such trouble occurs, the user may be required to
take corrective actions.
Class A Warning for Taiwan and Other Chinese Markets
This is a Class A Information Product. When used in a residential environment, it may cause radio
frequency interference. Under such circumstances, the user may be requested to take appropriate
countermeasure.
page -8                                              OmniSwitch 6865 Hardware Users Guide   October 2022
                                                                            Compliance and Certifications
Translated Safety Warnings
Chassis Lifting Warning
Two people are required when lifting the chassis. Due to its weight, lifting the chassis unassisted
can cause personal injury. Also be sure to bend your knees and keep your back straight when
assisting with the lifting of the chassis.
Français: Le châssis doit être soulevé par deux personnes au minimum. Pour éviter tout risque
d'accident, maintenez le dos droit et poussez sur vos jambes. Ne soulevez pas l'unité avec votre
dos.
Deutsch: Sicherheitshinweise Hinweise zur Anhebung des Chassis Zum Anheben des Chassis
werden zwei Personen benötigt. Aufgrund des Gewichts kann das Anheben ohne Unterstützung
zu Personenschäden führen. Heben Sie das Chassis aus den Knien und halten Sie den Rücken
gerade wenn Sie beim Anheben des Chassis assistieren.
Español: Se requieren dos personas para elevar el chasis. Para evitar lesiones, mantenga su
espalda en posición recta y levante con sus piernas, no con su espalda.
Electrical Storm Warning
To avoid a shock hazard, do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical storm.
Français: Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.
Deutsch: Hinweise bei Unwetter Um elektrische Schläge zu vermeiden dürfen während eines
Gewitters and diesem Gerät keine Kabel angeschlossen oder gelöst werden, sowie keinerlei
Installationen, Wartungen oder Konfigurationen vorgenommen werden.
Español: Para evitar peligro de descargas, no conecte o desconecte ningun cable, ni realice
ninguna instalación, maintenimiento o reconfiguración de este producto durante una tormenta
eléctrica.
Installation Warning
Only personnel knowledgeable in basic electrical and mechanical procedures should install or
maintain this equipment.
Français: Toute installation ou remplacement de l'appareil doit être réalisée par du personnel
qualifié
et compétent.
Deutsch: Installationshinweise Dieses Gerät soll nur von Personal installiert oder gewartet
werden, welches in elektrischen und mechanischen Grundlagen ausgebildet ist.
OmniSwitch 6865 Hardware Users Guide   October 2022                                               page -9
Compliance and Certifications
Español: Estos equipos deben ser instalados y atendidos exclusivamente por personal
adecuadamente formado y capacitado en técnicas eléctricas y mecánicas.
Invisible Laser Radiation Warning
Lasers emit invisible radiation from the aperture opening when no fiber-optic cable is connected.
When
removing cables do not stare into the open apertures. In addition, install protective aperture covers
to fiber with no cable connected.
Français: Des radiations invisibles à l'oeil nu pouvant traverser l'ouverture du port lorsque aucun
câble en fibre optique n'y est connecté, il est recommandé de ne pas regarder fixement l'intérieur
de ces ouvertures. Installez les caches connecteurs prévus à cet effet.
Deutsch: Hinweise zur unsichtbaren Laserstrahlung Die Laser strahlen an der Blendenöffnung
unsichtbares Licht ab, wenn keine Glasfaserkabel angeschlossen sind. Blicken Sie nicht in die
Öffnungen und installieren Sie unverzüglich die Abdeckungen über den Glasfaseranschlüssen.
Español: Debido a que la apertura del puerto puede emitir radiación invisible cuando no hay un
cable de
fibra conectado, procurar no mirar directamente a las aperturas para no exponerse a la radiación.
Power Disconnection Warning
Your switch may be equipped with multiple power supplies (redundant power supply
configurations).
To reduce the risk of electrical shock, be sure to disconnect all power connections before
servicing or moving the unit.
Français: Il se peut que cette unité soit équipée de plusieurs raccordements d'alimentation. Pour
supprimer tout courant électrique de l'unité, tous les cordons d'alimentation doivent être
débranchés.
Deutsch: Hinweise zur Spannungsfreischaltung Ihr Gerät ist mit mehreren Netzteilen ausgerüstet.
Um die Gefahr des elektrischen Schlages zu verringern, stellen sie sicher, daß alle
Netzverbindungen getrennt sind bevor das Gerät gewartet oder bewegt wird.
Español: Antes de empezar a trabajar con un sistema, asegurese que el interruptor está cerrado y
el cable eléctrico desconectado.
Proper Earthing Requirement Warning
To avoid shock hazard:
• The power cord must be connected to a properly wired and earth receptacle.
• Any equipment to which this product will attached must also be connected to properly
    wired receptacles.
• Use 22AWG solid copper conductor for ground leads connecting the frame to ground and DC
    return.
page -10                                               OmniSwitch 6865 Hardware Users Guide   October 2022
                                                                         Compliance and Certifications
•   Cleaning and dressing of grounding points during installation is strongly recommended. Also,
    do not forget the antioxidant.
•   To ground the equipment properly, connect a Panduit Corporation UL listed Lug, P/N: LCD8-
    10AL to the two threaded holes located on the rear using 8AWG copper conductors. Use
    Panduit Corporation, P/N: CT-940CH for crimping.
OmniSwitch 6865 Hardware Users Guide   October 2022                                          page -11
Compliance and Certifications
Français: Pour éviter tout risque de choc électrique:
• Ne jamais rendre inopérant le conducteur de masse ni utiliser l'équipement sans un conducteur
   de masse adéquatement installé.
• En cas de doute sur la mise à la masse appropriée disponible, s'adresser à l'organisme
   responsable de la sécurité électrique ou à un électricien.
Deutsch: Hinweise zur geforderten Erdung des Gerätes Aus Sicherheitsgründen:
• Darf das Netzkabel nur an eine Schutzkontaktsteckdose angeschlossen werden.
• Dürfen für den Anschluß anderer Geräte, welche mit diesem Gerät verbunden sind, auch nur
   Schutzkontaktsteckdosen verwendet werden.
Español: Para evitar peligro de descargas:
• Para evitar peligro de descargas asegurese de que el cable de alimentación está conectado a
   una toma de alimentación adecuadamente cableada y con toma de tierra.
• Cualquier otro equipo a cual se conecte este producto también debe estar conectado a tomas
   de alimentación adecuadamente cableadas.
Read Important Safety Information Warning
This guide contains important safety information users must be aware of when working with
hardware components in this system. Read this guide in its entirety before installing, using, or
servicing
this equipment.
Français: Avant de brancher le système sur la source d'alimentation, consultez les directives
d'installation disponibles dans ceci guide.
Deutsch: Bitte lesen - Sicherheitshinweise Dieses guide enthält wichtige
Sicherheitsinformationen, über die sie sich beim Arbeiten mit den Hardwareeinheiten bewußt sein
sollten. Sie sollten diese Hinweise lesen, bevor sie installieren, reparieren oder die Anlage
verwenden.
Español: Esto guide contiene información importante de seguridad sobre la cual usted debe estar
enterado al trabajar con los componentes de dotación física en este sistema. Usted debe leer esta
guía antes de instalar, usar o mantener este equipo.
Restricted Access Location Warning
This equipment should be installed in a location that restricts access. A restricted access location
is
one where access is secure and limited to service personnel who have a special key, or other
means
of security.
Français: Le matériel doit être installé dans un local avec accès limité ou seules les personnes
habilitées
peuvent entrer.
page -12                                               OmniSwitch 6865 Hardware Users Guide   October 2022
                                                                             Compliance and Certifications
Deutsch: Hinweis zu Umgebungen mit beschränktem Zutritt Die Anlage sollte an einem Standort
mit beschränktem Zutritt installiert sein. Ein Standort mit beschränktem Zutritt stellt sicher, daß
dort nur Servicepersonal mit Hilfe eines Schlüssels oder eines anderen Sicherheitssystems
Zugang hat.
Español: Este equipo se debe instalar en un sitio con acceso restrinjido. Un sitio con el acceso
restrinjido
es uno seguro y con acceso limitado al personal de servicio que tiene una clave especial u otros
medios de seguridad.
Wrist Strap Warning
Because electrostatic discharge (ESD) can damage switch components, you must ground yourself
properly before continuing with the hardware installation. For this purpose, Alcatel-Lucent
Enterprise provides a grounding wrist strap and a grounding lug located near the top-right of the
chassis. For the grounding wrist strap to be effective in eliminating ESD, the power supplies must
be installed in the chassis and plugged into grounded AC outlets.
Français: L'électricité statique (ESD) peut endommager les composants du commutateur. Pour
cette raison Alcatel-Lucent Enterprise joint à l'envoi du châssis un bracelet antistatique à brancher
sur la prise mise à la terre située en bas à droite du commutateur. Vous devrez mettre ce bracelet
avant toute intervention hardware.
Deutsch: Hinweise zur ESD (Elektrostatischen Aufladung) Weil elektrostatische Aufladung
(ESD) Teile der Anlage beschädigen könnten, müssen sie sich selbst erden, bevor sie mit der
Hardware Installation beginnen. Zu diesem Zweck stellt Alcatel-Lucent Enterprise ein
Erdungsarmband und eine Erdungsöse an der oberen rechten Seite des Chassis zur Verfügung.
Um eine sichere Erdungsfunktion des Erdungsarmbandes sicherzustellen, müssen die Netzteile
installiert und mit dem Schutzleiter des Versorgungsstromkreises verbunden sein.
Español: La descarga electrostática (ESD) puede dañar componentes eletrónicos. Usted debe
asegurarse
que está en contacto con tierra antes de hacer la instalación del equipo. Con este fin, Alcatel-
Lucent Enterprise proporciona una pulsera de muñeca para conectar al chasis en la toma de tierra
situada en la parte superior derecha del chasis. Para que la correa de muñeca sea eficaz en la
eliminación de ESD, las fuentes de alimentación deben estar instaladas en el chasis y conectadas
a enchufes CA con tierra adecuada.
Instrucciones de seguridad en español
Advertencia sobre el levantamiento del chasis
Se requieren dos personas para levantar el chasis. Debido a su peso, la elevación del chasis sin
ayuda
puede causar daños corporales. También es seguro doblar sus rodillas y guardar su espalda
derecho al
OmniSwitch 6865 Hardware Users Guide   October 2022                                              page -13
Compliance and Certifications
ayudar a levantar el chasis.
Advertencia de las tapaderas en blanco
Porque regulan la circulación de aire y ayudan a proteger componentes internos del chasis, las
tapaderas
en blanco deben seguir instaladas en las ranuras vacías del módulo y la fuente de alimentación
siempre.
Advertencia en caso de tormenta eléctrica
Para evitar peligro de descargas, no conecte o desconecte ningun cable, ni realice ninguna
instalación,
maintenimiento o reconfiguratión de este producto durante una tormenta eléctrica.
Advertencia de instalación
Solamente el personal bien informado en procedimientos eléctricos y mecánicos básicos debe
instalar o
mantener este equipo.
Advertencia de radiación láser invisible
Los lasers emiten radiación invisible de la apertura abierta cuando no se conecta ningún cable de
fibra
óptica. Al quitar los cables no mire fijamente en las aberturas abiertas. Además, instale las
cubiertas
protectoras de la abertura a las salidas de la fibra sin el cable conectado.
Advertencia de la batería de litio
Hay un peligro de la explosión si la batería del litio en su chasis se substituye incorrectamente.
Substituya la batería solamente por el mismo o el equivalente de tipo de batería recomendado por
el fabricante. Deseche las baterías usadas según las instrucciones del fabricante. Las instrucciones
del fabricante son como sigue: Devuelva el módulo con la batería del litio a Alcatel-Lucent. La
batería del litio será substituida en la fábrica de Alcatel-Lucent.
Advertencia sobre la tensión de operación
Para reducir el riesgo del choque eléctrico, matenga sus manos y dedos fuera de la fuente de
alimentación y no toque la placa madre mientras que el interruptor está funcionando.
Advertencia sobre la desconexión de la fuente
Su interruptor esta equipado por fuentes de alimentación múltiples. Para reducir el riesgo de
choque eléctrico, asegúrese desconectar todas las conexiones de alimentación antes de mantener o
de mover la unidad.
Advertencia sobre una apropiada conexión a tierra
Para evitar peligro de descargas:
page -14                                              OmniSwitch 6865 Hardware Users Guide   October 2022
                                                                            Compliance and Certifications
        El cable de alimentación debe estar conectado a una toma de alimentación
        adecuadamente cableada y con toma de tierra.
Cualquier equipo al cual se conecte este producto debe estar también conectado a tomas de
alimentación adecuadamente cableadas.
Leer “información importante de seguridad”
La Guía de “Comenzando a Usar” que acompaña este equipo contiene información importante de
seguridad sobre la cual usted debe saber al trabajar con los componentes de dotación física en este
sistema. Usted debe leer esta guía antes de instalar, de usar, o de mantener este equipo.
Advertencia de acceso restringido
Este equipo se debe instalar en una ubicación que restrinja el acceso. Una ubicación con acceso
restringido es una donde está seguro y limitado el acceso al personal de servicio que tiene un
clave especial, u
otros medios de la seguridad.
Advertencia de pulsera antiestática
Debido a que la descarga electrostática (ESD) puede dañar componentes del interruptor, usted
debe conectarse
a tierra correctamente antes de continuar con la instalación del equipo. Para este propósito,
Alcatel- Lucent proporciona una pulsera antiestática y un terminal que pone a tierra situados
cerca de la parte superior
derecha del chasis. Para que la pulsera antiestática sea eficaz en la eliminación de ESD, las
fuentes de alimentación se deben instalar en el chasis y enchufar en las salidas de CA con
descarga a tierra.
Clase de seguridad
Cumple con 21CFR 1040.10 y 1040.11 ó sus equivalentes.
OmniSwitch 6865 Hardware Users Guide   October 2022                                             page -15
Compliance and Certifications
page -16                        OmniSwitch 6865 Hardware Users Guide   October 2022