300639 BRO Precision Flo LT 4/25/03 12:56 PM Page 10
Technical Specifications
      Minimum flow rates* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 cc/minute with G3000HR meter
                                                                                                                      75 cc/minute with G3000 meter
                                                                                       50 cc/minute with high resolution Helical flow meter
                                                                               100 cc/minute with Helical flow meter (ambient/heated)
      Maximum flow rates* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500 cc/minute with G3000HR meter
                                                                                                                  2000 cc/minute with G3000 meter
                                                                                   3750 cc/minute with high resolution Helical flow meter
                                                                             7500 cc/minute with Helical flow meter (ambient/heated)
      Maximum fluid working pressure
         feed pressure to fluid pane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5000 psi (345 bar, 34.5 MPa)
         at regulator outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4500 psi (310 bar, 31 MPa)
         at regulator outlet with electric heat components . . . . . . . . . . . . . . . . . . . . . . 3500 psi (241 bar, 24 MPa)
      Minimum fluid working pressure
         at regulator outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 psi (34.5 bar, 3.5 MPa)
      Minimum back pressure
         between regulator outlet and dispense nozzle . . . . . . . . . . . . . . . . . . . . . . . . . 500 psi (34.5 bar, 3.5 MPa)
      Air supply pressure range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60-120 psi
                                                                                                                             (4.1- 8.3 bar, 0.4 - 0.8 MPa)
                                                                                                                                          filtration required
      Fluid filtration required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 mesh (500 micron) minimum
      Viscosity range of fluids* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 to 50000 cps with G3000 meter
                                                                                                      10000 to 1000000 cps with Helical meter
      Minimum dispensed shot size* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 cc with G3000HR meter
                                                                                                                                   6 cc with G3000 meter
                                                                                                                                    7 cc with Helical meter
                                                                                                            4 cc with High Resolution Helical meter
      V/P output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 5 VDC provide 0 to 100 psi (68 MPa, 6.8 bar)
      Wetted parts
         meters and fluid panels . . . . . . . . . . . . . . . . . . . . . 303, 304, 321, 17- 4 stainless steel; tungsten carbide,
                                                                                                                                          PTFE, steel, Viton®
      Power requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Full Load Amps - 1, Fused Amps - 2
      Power supply voltage range
         120 VAC nominal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 - 264 VAC, 50-60 Hz., single phase
      Operating temperature range
         Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40° - 122° F (4° - 50° C)
         Fluid panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40° - 400° F (4° - 204° C)
      Operating humidity range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 - 90% non-condensing
      *Flow rates and viscosities are general estimates. Flow rates drop as viscosity increases. Fluids are expected to
       shear under pressure. New applications or fluids should always be tested to determine proper line sizes and
       equipment selections.
      See your Graco Authorized distributor for other capabilities
      Viton® is a registered trademark of the DuPont Company.