Caledonian

DATABUS CABLES
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRA-Cat5E-4C0.5S
Maximum Characteristic Transfer Maximum
Nominal Nominal Maximum
Nominal Cross Nominal Conductor Impedance Impedance Capacitance
Sheath Overall Resistance
Sectional Area Weight Resistance
Thickness Diameter Unbalance core to Core to
20℃ @100MHz f<=30MHz
core screen
mm2 mm mm kg/km Ω/km Ω/km Ω mΩ/m pF/m pF/m
0.5 1.2 8.3 102 40.1 1.1 100+/-5 200 65 100

FRA-Cat5E-4C22A
Maximum Characteristic Transfer Maximum
Nominal Nominal Maximum
Nominal Conductor Impedance Impedance Capacitance
AWG Sheath Overall Resistance
Weight Resistance core to Core to
Thickness Diameter Unbalance @100MHz f<=30MHz
20℃ core screen
mm mm kg/km Ω/km Ω/km Ω mΩ/m pF/m pF/m
22 1.2 7.25 81 54.4 1.1 100+/-5 200 65 100

FRA-Cat5E-4P22A
Maximum Characteristic Transfer Maximum
Nominal Nominal Maximum
Nominal Conductor Impedance Impedance Capacitance
AWG Sheath Overall Resistance
Weight Resistance core to Core to
Thickness Diameter Unbalance @100MHz f<=30MHz
20℃ core screen
mm mm kg/km Ω/km Ω/km Ω mΩ/m pF/m pF/m
22 1.2 12.6 174 54.4 1.1 100+/-5 200 65 100

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


66
Caledonian
DATABUS CABLES

DATABUS RS 485 CABLE 300/500V

Application
120Ohm data transmission cables

Construction
Multipair Databus RS 485 Double screened Cable
Conductor: Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2).
Insulation: Cross linked Foam PE.
Cable Element:Twisted pair.
Individual Screen:Individual Aluminium Tape.
Overall Screen: Copper Wire Braid
Outer Sheath:Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1.
Multipair Databus RS 485 Single screened Cable
Conductor: Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2).
Insulation: Cross linked Foam PE.
Cable Element:Twisted pair.
Overall Screen: Copper Wire Braid
Outer Sheath:Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1.

Electrical & Mechanical Properties


Nominal Voltage 300/500V
Impedance 120Ω+/-15%
Capacitance@1KHz 41nF/km
Insulation Resistance 5000MΩ

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density

67
Caledonian
DATABUS CABLES
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

300/500V Multipair Databus RS 485 Double screened Cable


Nominal Cross Sectional Nominal Diameter of
Nominal Overall Diameter Nominal Weight
No.of pair Area Strands
mm2 No/mm mm kg/km
1 0.22 7/0.2 4.5 58
2 0.22 7/0.2 6.2 79
4 0.22 7/0.2 6.5 118
1 0.5 16/0.2 6.6 79
2 0.5 16/0.2 9.0 105
4 0.5 16/0.2 9.8 145
1 0.75 24/0.2 9.5 115
2 0.75 24/0.2 10.3 135
4 0.75 24/0.2 11.6 182
1 1 30/0.2 11.5 125
2 1 30/0.2 12.5 150
4 1 30/0.2 13.5 180

300/500V Multipair Databus RS 485 Single screened Cable


Nominal Cross Sectional Nominal Diameter of
Nominal Overall Diameter Nominal Weight
No.of pair Area Strands
mm2 No/mm mm kg/km
1 0.22 7/0.2 4.2 55
2 0.22 7/0.2 5.9 75
4 0.22 7/0.2 6.2 115
1 0.5 16/0.2 6.3 75
2 0.5 16/0.2 8.5 100
4 0.5 16/0.2 9.4 140
1 0.75 24/0.2 9.0 110
2 0.75 24/0.2 9.7 130
4 0.75 24/0.2 11.1 178
1 1 30/0.2 11.0 120
2 1 30/0.2 12.0 145
4 1 30/0.2 13.0 175

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


68
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types IV Rolling Stock Cables
30/50V Singlecore Reduced Wall Unsheathed Cables

A.Conductor B.Insulation

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
Conductor
Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor
Nominal Weight
No.of core Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
1 0.5 19/0.18 1.34 6 40.1
1 0.75 37/0.16 1.56 8 26.7
1 1.0 37/0.18 1.69 10 20.0
1 1.5 37/0.23 2.07 16 13.7
1 2.5 37/0.30 2.66 27 8.21
1 4.0 37/0.37 3.32 41 5.09

IEC 60332-1/IEC 60332-3C