What Combi Control does?			 6                                    Setup reset				30
Indicator lights			8                                             User setup				31
Buttons				10                                                    Multiple commands			32
Power				12                                                      Heat pump model setup			       34
SIM card				12                                                   Alarm messages			36
Installing Combi Control			 14                                   Error messages			39
Testing Combi Control			    19                                   Report messages			40
Turning heat pump ON/OFF		  20                                   Combi Control command sheets		 44
Commands				22                                                   Get in touch with us			        46
User levels				24
Owner setup				26
Owner number reset			       27
                                                             All manuals and user guides at all-guides.com
What Combi
Control does?
Combi Control is a heat pump controller you operate
with a mobile phone. It is compatible with most
popular Toshiba heat pumps and all mobile phones (see
CombiControl.eu for the complete list).
The easiest way to use Combi Control is with a
Smartphone, using the Combi Control app downloadable
from the Android Market (for Android phones ) or App
Store (for iPhone). It can also be controlled with regular
mobile phone text messages (SMS). Combi Control allows
you to have long distance control over the mode of the
pump, room temperature and fan speed settings. Combi
Control can also inform you about low room temperature,
power failures and heat pump service intervals.
6
                                                             All manuals and user guides at all-guides.com
Indicator lights
The controller has 3 LED indicators and 2 buttons for
easy setup. It has also 2 infrared LEDs that transmit your
commands to the heat pump.
LED 1 - Power
on switched on
blinking no power, working on battery
off switched off
LED 2 - mobile phone LED
on restart time, SIM missing or SMS processing
1 blink (3 s interval) normal status
3 blinks (3 s interval) no signal from mobile phone or not
connected to a mobile network
blinking (500 ms interval) data call session is active
LED 3 - IR LED                                                                               LED 1 - Power
blinking transmitting by IR
                                                                                             LED 2 - mobile phone LED
                                                                                             LED 3 - IR LED
8
                                                                 All manuals and user guides at all-guides.com
                                                                                           m
                                                                             .co
Buttons
Use a straightened paper clip or something similar to push
the recessed buttons.
RESET button
Short push turns the controller off when working on
                                                                  es
battery
The controller has a battery that keeps it operational even
if it’s disconnected from a wall outlet. To fully turn off the
controller, push the RESET button. The 3 LED lights will
blink for about a second and the controller switches off.
                                                   uid
Use this button also to clear the most recent settings (the
Owner number will remain unchanged).
TEST button                                                                                      RESET button
Short push turns the heat pump ON/OFF
Use the TEST button to confirm that the IR beam from the                                         TEST button                                IR beam
controller reaches the heat pump.
                                  -g
                                                                                                 NB! Pushing both buttons simultaneously for 3 seconds initiates the hard reset: restores
                                                                                                 factory settings, deletes Owner number and heat pump settings (same function as with
10
               all
                                                                All manuals and user guides at all-guides.com
Power
When the power is out (power = 0V) the controller
continues to work on the battery and turns off after the
battery’s voltage drops below 3.5V. A fresh battery lasts
for approximately 24 hours (note that over time the
battery’s capacity decreases). After the controller is turned
off the run time will be saved. To save battery life when
the power is out the controller can be turned off with a
short push on the RESET button.
SIM card
NB! Make sure you disable the PIN code of the SIM card
you use in Combi Control.
NB! Make sure the SIM card you use in Combi Control can
access 2G network. Combi Control is not compatible with
SIM cards that use only 3G network.
                                                                                                A) Make sure that you have previously disabled the SIM card PIN code.
                                                                                                Insert SIM card as shown into Combi Control.
                                                                                                B) Plug the adapter into the socket under the Combi Control.
12
                                                               All manuals and user guides at all-guides.com
Installing
                                                                                                               Fig. 1
Combi Control                                                                                                  On the right side of
                                                                                                               the indoor unit
Combi Control should be mounted on the wall to the right
of your heat pump’s indoor unit (see fig. 1), with its IR
transmitter pointing down. This way
the IR beam is reflected from the floor and reaches the heat
pump’s sensor most efficiently.
Other mounting configurations are possible too
as long as IR transmission from the controller
to the pump works.
NB! Thick carpets and dark floors can distort the IR beam.                                                     Fig. 2
Make sure the IR beam reaches the pump’s sensor by using
the controller’s Test function (see page 19).                                                                  Attached to the right side of
                                                                                                               the indoor unit
14
            All manuals and user guides at all-guides.com
Fig. 3                                                      Fig. 5
Beneath the indoor unit                                     On a ledge, opposite to the
                                                            indoor unit
Fig. 4
On the wall, opposite to
the indoor unit
            All manuals and user guides at all-guides.com
                                            Testing Combi
Fig. 6, 7
                                            Control
Do not place Combi Control
on the left side of the indoor
unit!                                       To see if Combi Control can send commands to your
Indoor unit’s internal                      heat pump, turn off the pump and press the controller’s
condenser might block Combi                 TEST button. When the connection is established, Combi
Control’s signal.                           Control turns the pump on with its last settings and you
                                            can proceed using the controller.
                                                                                                       19
                                        All manuals and user guides at all-guides.com
                                                                  m
                                                    .co
Turning heat
pump ON/OFF
SMS Command ON turns heat pump on.
SMS Command OFF turns heat pump off.
                                         es
                                                                           sms:         sms:
                                                                              ON         OFF
                                       uid
                            -g
20
            all
                                                            All manuals and user guides at all-guides.com
Commands
The range of heat pump temperature values Combi
Control controls is 16-30 °C (default +20 °C) and the fan
speeds are MIN, NORM, MAX
(the default is NORM).
                                                                                                 AUTO                              16                      MIN
After selecting a mode (AUTO, DRY, COOL, HEAT, T8, T10)
heat pump is turned on with 20 °C maximum temperature
                                                                                                 DRY                               17                      NORM
and normal fan speed, if not assigned differently by the
Owner or the Users (see pages 24 and 29 for how to set                                                                             18
the Owner and Users).                                                                            COOL                                                      MAX
                                                                                                                                   ...
The pump can be assigned different temperature and fan                                           HEAT
speed values with Combi Control.                                                                                                   28
                                                                                                 T8
For example, the SMS: “COOL 19 MAX” orders the pump
to cool until 19 °C and fan at maximum speed. When                                                                                 29
you change a heat pump function Combi Control always
responds with an SMS that reports its STATUS (see page 39                                        T10                               30
for full STATUS report explanation).
                                                                                            Combine the pump mode, room temperature and fan speed values for a home
                                                                                            atmosphere you like the best.
22
                                                           All manuals and user guides at all-guides.com
User levels
The amount of control Combi Control users have over the
device and the amount of information they receive from
the device can be set on a 3 level scale:
1. The Owner can send commands, report queries, setup
commands and receive Combi Control report messages
and alarm messages.
2. The Users can send commands and report queries to
Combi Control but cannot send Setup commands.
3. The All-level users can make report queries about the
status of the controller.
24
                                                             All manuals and user guides at all-guides.com
Owner setup                                                                                  to change setup will be ignored. When no Owner number
                                                                                             has been entered all numbers have Owner rights (all
                                                                                             numbers can assign themselves as owners and no alarm
                                                                                             messages will be sent). When the Owner has not set User
Setup can only be performed by the Owner. When no                                            numbers, all numbers have User rights.
Owner has been previously set, Owner number can be
sent from any mobile phone number. There are 2 ways                                          Should you suspect Combi Control could be controlled
to do this:                                                                                  from unapproved numbers, we recommend you set the
                                                                                             Owner and User numbers.
The to-be Owner sends the SMS “93” to the controller. The
SMS containing “93” followed
by the mobile number of the to-be Owner –
e.g. “935012345”– is sent from any mobile phone.
                                                                                             Owner number
The Owner number can be international (with the “+”
                                                                                             reset
symbol and country code) or local. The length of the
number must be between 3-16 symbols (“+” counts as                                           Once set, Owner number can be reset via mobile phone
1 symbol).                                                                                   only by the Owner himself or by performing a hard reset
                                                                                             by pushing both controller hidden buttons simultaneously
Successful Owner number entry/Owner number change                                            for 3 seconds (hard reset can also be used when a wrong
is confirmed by “VERSION” report SMS sent to the new                                         Owner number is entered by mistake).
Owner (see page 40 for full “VERSION” report explanation).
After Owner number has been set up, setup can be done
from this Owner number. All other numbers attempting
26                                                                                                                                                      27
     All manuals and user guides at all-guides.com
                                                     Advanced setup
                                                      For the brave!
28
                                                                       All manuals and user guides at all-guides.com
                                                                                                 m
                                                                                         .co
Setup reset                                                                                            User setup
For setup reset send the SMS “90” to the controller. Combi Control responds with SETUP                 To set User numbers start your command SMS with “91”, followed by the mobile phone
report:                                                                                                number of the User. For example: “91+495012345” or “915012345” to enter User1
                                                                                                       number where “5012345” is the cell phone number of User1 and +49 is the country
“Owner: All; Users: All; Pump: All; Ring 2,2,2; Param: 5, 24, 180”.                                    code. User numbers (Owner, User1, User2) can be international (with the “+” symbol and
                                                                          es
                                                                                                       country code) or local. The length of the number must be between 3-16 symbols
This means Owner is not specified; all users can send commands;                                        (“+” counts as one symbol). Multiple commands can be combined into one SMS. When a
the pump model is not specified, call commands are set to default;                                     User has been set, Combi Control responds with a SETUP report message.
“LOW TEMPERATURE” message will be sent when room temperature drops below 5 °C ,
“NO POWER” message blackout is in 24 hours and the “SERVICE” alarm message interval
is 180 days.
                                                 uid
                                                                                                         Setup SMS command you send               Controller function you activate
     Setup SMS command you       Response SMS       Controller function you activate                     91xx*                                    User1 number entry (to delete: 910)
     send                                                                                                92xx*                                    User2 number entry (to delete: 920)
                                                    Setup reset (Owner deleted)                          93xx*                                    Owner number entry (to delete: 930)
     90                          SETUP
                                                    and controller restart
                                 -g
                                                                                                       *xx marks the place of mobile phone number
30                                                                                                                                                                                         31
                all
                                                                  All manuals and user guides at all-guides.com
Multiple commands                                                                                 Heat pump model setup
If you want to set up several parameters with one SMS, separate commands with one of the          The pump can be chosen on 3 levels of precision:
following:
space                                                                                             1. The precise name of the pump: the manufacturer and the model.
comma “,”                                                                                         This is recommended for the most efficient operation.
semicolon “;”
                                                                                                  2. Pump manufacturer.
For example, the SMS „91+49550111111 92+49550222222 9522 9720”                                    If you only choose the pump manufacturer, functions T8 will not be checked and the
sets the User1 and User2 numbers, specifies the heat pump model as “Toshiba Daiseikai 5”,         command will be sent even if the pump does not have
and determines that NO POWER message will not be sent in case of a power failure.                 T8 mode. If the exact pump model is not listed on our webpage or in this manual,
                                                                                                  Combi Control may or may not work with the heat pump, for which the Combi Control
When a command in the multi-setup is incorrect, the Owner will receive an error message.          manufacturer will not be held responsible.
All the correct commands that precede the error command in the multi-setup command
will be activated.                                                                                3. All pump models.
                                                                                                  If you choose All pump models (SMS: “950”), then all supported brands IR commands will
Multi-setup sender will always receive SETUP report SMS from Combi Control to confirm             be sent to the pump, and Combi Control can be used without choosing the pump more
that all commands arrived to the controller. There can be spaces before and after a               precisely.
command but not inside a command as this will interfere with the code.
32                                                                                                                                                                                     33
                                                            All manuals and user guides at all-guides.com
     Setup SMS command        Heat pump model and series          T8*
     you send
     950                      All pump models                     T8
     952                      Toshiba                             T8
     9521                     Toshiba Daiseikai 3                 T8
     9522                     Toshiba Daiseikai 5                 T8
     9523                     Toshiba Daiseikai 6                 T8
* T8 is a heat pump function that keeps the room temperature from dropping below
8 °C respectively.
34                                                                                                          35
                                                                    All manuals and user guides at all-guides.com
Alarm messages setup                                                                                When you set parameter 971 to 0, (e.g. you send a text message “9710”) then the
                                                                                                    controller will not send you a “LOW TEMPERATURE” message.
The Owner can change the default values of the conditions on which alarm messages                   When you set parameter 972 to 0, then “NO POWER” message will not be sent.
are sent. For example, SMS “9713” lowers the room temperature value at which “LOW
TEMPERATURE” SMS is sent from the default 5 °C to 3 °C.                                             When you set parameter 973 to 0, then “SERVICE” message will not be sent.
     Setup SMS      Response       Combi Control function you activate    Default
     command you    SMS format                                            values
     send                                                                                           Alarm messages
                                   temperature treshold for                                         Alarm messages are only sent to the Owner.
     91xx*          SETUP                                                 5 °C
                                   „LOW TEMPERATURE” message
                                                                                                      Combi Control alarm SMS         Alarm message meaning         Message blackout/
                                   “NO POWER” message blackout                                                                                                      alarm treshold
     92xx*          SETUP                                                 24 h
                                   in hours
                                                                                                      e.g. “LOW TEMPERATURE:
                                                                                                                                     Room temperature is low        24h / +5 °C
                                   “SERVICE” message interval                                         6 °C” (when the limit is 7 °C)
     93xx*          SETUP                                                 180 days
                                   in days
                                                                                                      NO POWER                        220V power failure            Default: 24h
* xx marks the place of the numeric value                                                             e.g. ”SERVICE: 1 days”          Service date                  Default: 180 days
The „LOW TEMPERATURE” parameters (971) can be between 0-16
                                                                                                                                                                    After setting a new
The “NO POWER” parameters (972) can be between 0-48                                                   VERSION                         New Owner                     Owner or changing
The “SERVICE” parameters (973) can be between 0-360                                                                                                                 Owner
36                                                                                                                                                                                        37
     All manuals and user guides at all-guides.com
                                     Error messages
                                     “Error command: text”
                                     SMS will be sent if there was an error in your command.
                                     For example, an SMS “cool19max” receives the response
                                     “Error command: cool19max”. Note that Combi Control will only return your incorrect
                                     command without suggesting a correct one (the error in the example is the absence of
                                     spaces between commands).
                                     “Error userrights: text”
                                     SMS will be sent if the user had no rights for that command.
                                     “Error pump command: text“
                                     SMS means the operation T8 is not available for the specified pump.
                                     When Combi Control fails to send an SMS it will retry after 1 minute.
38                                                                                                                          39
                                                                     All manuals and user guides at all-guides.com
                                                                                               m
                                                                                             .co
Report messages                                                                                      Pump ”STATUS” report explanation
                                                                                                      Pump “STATUS” report            Response SMS example
You can send report requests to Combi Control about your heat pump status, controller                 SMS Format
status and the setup of the controller. Report messages are sent only to the sender of the            Pump: ON/OFF/NO POWER           Pump ON/OFF/NO POWER
request.
                                                                                                      Mode: AUTO/DRY/COOL/HEAT/T8/T10 Pump mode
                                                                       es
                                                                                                      Fan: AUTO/MIN/NORM/MAX          Fan speed
     SMS        SMS command       Response SMS example
     command    function                                                                              Temp: xxC                       Pump temperature
     you send
                                                                                                      Room: xxC                       Room temperature
                Pump status
     STATUS                       Pump: ON; Mode: HEAT; Fan: MAX;
                request
                                                uid
                               Ver: 1.01b05; Pump: Toshiba, ON; Power: ON
                Controller
     VERSION                   (4.37V); Room: 19C; GSM: 14,1; Life: 00.05;
                status request
                               Owner: +49550111111;
                                  Owner: +49550111111; Users: All; Pump: Toshiba,
     SETUP      Setup request
                                  ON/OFF/NO POWER; Ring: 2,2,2; Param: 5,24,180;
                                -g
40                                                                                                                                                           41
                all
                                                     All manuals and user guides at all-guides.com
Controller “VERSION” report explanation                                              ”SETUP” report explanation
     SMS format                Explanation                                            SMS format                      Explanation
     Ver: version number       Combi Control firmware version                         Owner: number / All             Owner number or All if not defined
     Pump: type,ON/OFF         Pump status: type and ON/OFF                                                           User1 and User2 number or All if not
                                                                                      Users: number1, number2 / All
                                                                                                                      defined
                               Voltage 5V input and battery voltage
     Power: ON/OFF(x.xxV)
                               (3.50V-4.20V)                                                                          Chosen pump model:
                                                                                      Pump: pump manufacturer’s and
                                                                                                                      Toshiba
     Room: xxC                 Room temperature in Celsius degrees                    model name
                                                                                                                      ALL
                               GSM signal strength (0-31,99) and GSM                  Ring: x,x1,x2                   Ring codes: Owner, User1, User2
     GSM: sq, cell
                               area info (1-local network, 5-roaming)
                                                                                                                      Parameters: 971 (low temperature),
     Life: mm.dd               Controller run time: months, days                      Param: x1,x2,x3
                                                                                                                      972 (no power), 973 (service)
     Owner: number             Owner mobile phone number
42                                                                                                                                                           43
                                                       All manuals and user guides at all-guides.com
Heat pump ON/OFF                                                                       Heat pump model setup
                                                                                        Setup command SMS      Heat pump model and series   T8
     Command SMS                 Heat pump function                                     you send
     ON                          Pump ON                                                950                    All pump models              T8
     OFF                         Pump OFF                                               952                    Toshiba                      T8
                                                                                        9521                   Toshiba Daiseikai 3          T8
Restart and Owner number entry
     Command SMS                 Controller function                                    9522                   Toshiba Daiseikai 5          T8
                                 Setup reset (Owner deleted)                            9523                   Toshiba Daiseikai 6          T8
     90
                                 and controller restart
Commands
     Command SMS                 Heat pump function
     AUTO                        AUTO (+20 °C, fan: NORM)
     DRY                         DRY (+20 °C, fan: NORM)
     COOL                        COOL (+20 °C, fan: NORM)
     HEAT                        HEAT (+20 °C, fan: NORM)
     T8                          T8 mode
44                                                                                                                                               45
                       All manuals and user guides at all-guides.com
Get in touch with us
46
All manuals and user guides at all-guides.com