GENERAL INSTALLATION MANUAL
● ● ● ● ● ●   FOR PERLIGHT PV MODUELS          ● ● ● ● ● ●
                                                                                        2.   Contact with electrically active parts of a PV module such as terminals can result in
1. INTRODUCTION                                                                              burns, sparks and lethal shock whether the PV modules is connected or not.
This installation Manual contains essential information for the electrical and          3.   PV modules produce electricity when the sufficient sunlight or other sources
mechanical installation that your must know before installing PERLIGHT PV                    illuminate the module surface. When the modules are connected in series, voltage
modules. This also contains safety information you need to be familiar with .All the         id cumulative . When the modules are connected in parallel, current is cumulative.
information described in this manual are the intellectual property of PERLIGHT               As a result, a large-scale PV system can produce high voltage and current which
and based on the technologies and experiences that have been acquired and                    could present an increased hazard and may cause serious injury or death.
accumulated in the long history of PERLIGHT. This document does not constitute          4.   Do not connect the PV modules directly to the loads such as motor since the
a warranty, expressed or implied.                                                            variation of the output power depending on the solar irradiation cause damage for
PERLIGHT does not assume responsibility and expressly disclaims liability for                the connected motor.
loss, damage, or expense arising out of in anyway connected with installation,               1:In the case of a blushless motor, the lock function becomes active and the hall IC
operation, use or maintenance of the PV modules. No responsibility is assumed                is most likely to be damaged.
by PERLIGHT for any infringement of patents or other rights of third parties that            2:In the case of a brush type motor, the coil is most likely to be damaged.
may result from use of PV module.
PERLIGHT reserves the right to make changes to the product, specifications or                <WORK PRINCIPLE>
installation manual without prior notice.
2. GENERAL INFORMATION
       (INCLUDING WARING AND SAFETY)
The installation of PV modules requires a great degree of skill and should only be
performed by a qualified licensed professional, including licensed contractors and
licensed electricians. Please be aware that there is a serious risk of various types
of injury occurring during the installation including the risk of electric shock. All
PERLIGHT modules are equipped with a permanently attached junction terminal
box that will accept variety of wiring applications or with a special cable assembly
for ease of installation, and they do not require assembly.                                  <GENERAL SAFETY>
                                                                                             1.   Consult local codes and other applicable laws concerning required permits on
<GENERAL WARNING>                                                                                 regulations concerning installation and inspection requirements.
1.   Before you attempt to install wire, operate and maintain the PV module,                 2.   Before installation a PV module, contact appropriate authorities to determine
     please make sure that you completely understand the information described                    permit, installation and inspection requirements that should be followed.
     in this installation manual.                                                            3.   Install PV modules and ground frames in accordance with applicable rules and
                                                                                                                                                                                1
        GENERAL INSTALLATION MANUAL
      ● ● ● ● ● ●    FOR PERLIGHT PV MODUELS            ● ● ● ● ● ●
     regulations                                                                               will not be damaged.
4.   PV modules should be installed and maintained by qualified personnel.                 14. Do not expose PV module to sunlight concentrated with mirrors, lenses or
     Only installer/service personnel should have access to the PV module                      similar means.
     installation site.                                                                    15. Turn off inverters and circuit breakers immediately, should a problem occur.
5.   No matter where the PV modules are installed, either roof mounted                     16. In case the glass surface of a PV module is broken, wear goggles and tape the
     construction or any other type of structures above the ground,                            glass to keep the broken pieces in place.
     appropriate safety practices should be followed and required safety                   17. A defective PV module may generate power ever if it is removed from the
     equipment should be used in order to avoid possible safety hazards.                       system. It may be dangerous to handle the PV module while exposed to
     Note that the installation of some PV modules on roofs may require the                    sunlight. Place a defective PV module in a carton so PV cells are completely
     addition of fireproofing, depending on local building / fire codes.                       shaded.
6.   Please use PV modules with same cell size within series.                              18. In case of series connection , the maximum open circuit voltage must not be
7.   Follow all safety precautions of other components used in the system.                     greater than the specified maximum system voltage. The voltage is
8.   In order to avoid a risk of injury or electrical shock, do not allow anyone to            proportional to the number of series. In case of parallel connection, please be
     approach the PV module if the person has little knowledge on PV module                    sure to take proper measure to block the reverse current flow. The current may
     or on the measures that should be taken when PV modules are                               easily flow in a reverse direction.
     damaged.
9.   Do not clean the glass surface with chemicals. Do not let water stay on          <HANDLING SAFETY>
     the glass surface of PV modules for a long time. This creates a risk of          1.   Do not cause an excessive load on the surface of PV module or twist the frame.
     white efflorescence(glass disease) which may result in the deterioration              The glass surface can easily break.
     of energy generation.                                                            2.   Do not stand or step on the PV module. The surface glass of PV module is slippery.
10. Do not clean the glass surface with chemicals. Do not let water stay on           3.   Do not hit or put excessive load on the glass or brake film. The PV cell is very thin
     the glass surface of PV modules for a long time. This creates a risk of               and can be easily broken.
     white efflorescence ( glass disease ) which may result in the deterioration      4.   Do not scratch or hit at the back film. The back film is vulnerable.
     of energy generation.                                                            5.   Do not hit the terminal box or do not pull the cables. The terminal box can crack
11. Do not install the PV module horizontally. It may cause dirt or white                  and break.
     efflorescence (glass disease) due to water.                                      6.   Never touch terminal box or the end of output cables with bare hands when the PV
12. Do not cover the water drain holes of the frame. There is a risk of frost              module is irradiated. Cover the surface of PV module with cloth or other suitable
     damage when the frame is filled with water copulation.                                sufficiently opaque material to isolate the PV module from incident light and handle
13. When sliding snow load has to be considered, an appropriate measure                    the wires with rubber-gloved hands to avoid electric shock.
     has to be taken so that PV module frames on lower edge of PV modules             7.   Do not scratch the output cable or bend it with force. The insulation of output cable
                                                                                                                                                                              2
            GENERAL INSTALLATION MANUAL
          ● ● ● ● ● ●    FOR PERLIGHT PV MODUELS          ● ● ● ● ● ●
     can break and may result in electricity leakage or shock.                          module installation and wiring.
8.   Do not pull the output cable excessively. The output cable may unplug and      11. Plug in the connector tight and ensure the wiring work.
     cause electricity leakage or shock.                                            12. Due to the risk of electrical shock, do not perform any work if the terminals of PV
9.   Do not drill holes in the frame. It may compromise the frame strength and          module are wet.
     cause corrosion of the frame.                                                  13. Do not touch the terminal box and the end of output cable ends ( connectors) with
10. Do not scratch the insulation coating of the frame(except for grounding             bare hands during installation or under sunlight, regardless of whether the PV
     connection).It may cause corrosion of the frame or compromise the                  module is connected to or disconnected from the system.
     framework strength.                                                            14. Do not unplug the connector if the system circuit is connected to a load.
11. Do not loosen or remove the screws of the PV module. It may compromise          15. Do not stamp on the glass at work. There is a risk of injury or electric shock if glass
     the joint strength of PV module and cause corrosion.                               is broken.
12. Do not touch the PV module with bare hands. The frame of PV modules has         16. Do not work alone (always work as a team of 2 or more people).
     sharp edges and may cause injury.                                              17. Wear a safety belt if working far above the ground.
13. Do not drop PV module or allow objects to fall down on the PV module.           18. Do not wear metallic jewelry which can cause electric shock during installation.
14. Do not try artificially to concentrate sunlight on the PV module.               19. Do not damage the surrounding PV modules or mounting structure when replacing
                                                                                        a PV module.
<INSTALLATION SAFETY>                                                               20. Bind cables by the insulation locks. Drooping down of cables from the terminal
1.   Always wear protective head gear, insulating gloves and safety shoes (with         box could possibly cause various problems such as animal biting electricity
     rubber soles).                                                                     leakage in puddle.
2.   Keep the PV module packed in the carton until installation.
3.   Do not touch the PV module unnecessarily during installation. The glass        3.COMPONENTS
     surface and the frames get hot. There is a risk of burn, or you may collapse
     because of electric shock.
4.   Do not work under rain, snow or windy conditions.
5.   Use insulated tools
6.   Do not use wet tools
7.   Do not drop tools or hard objects on PV modules
8.   When installing PV modules far above ground, do not drop any object(e.g. PV
     module or tools).
9.   Make sure flammable gases are not generated near the installation site.
10. Completely cover the PV module surface with an opaque material during PV
                                                                                                                                                                             3
            GENERAL INSTALLATION MANUAL
          ● ● ● ● ● ●   FOR PERLIGHT PV MODUELS           ● ● ● ● ● ●
                                                                                      6. WIRING
                                                                                      To ensure proper system operation
4. SITE SELECTION                                                                     to maintain your warranty, observe
In most applications, the PV modules should be installed in location where there is   the   correct      cable     connection
no shading throughout the year. In the Northern Hemisphere, The PV modules            polarity(Figures      1&2)        when
should typically face south, and in the Southern Hemisphere, the PV modules           connecting the modules to a battery
should typically face north. Please make sure that there are no obstruction in the    or to other modules. If not connected
surroundings of the site of installation. Take proper steps in order to maintain      correctly, the bypass diode could be
reliability and safety, in case the PV modules are used in areas such as: Heavy       destroyed.
snow areas/Extremely code areas/ Strong wind areas/Installation over, or near,        PV modules can be wired in series to
water/ Areas where installations are prone to salt water damage (*)/Small islands     increase voltage. Connect wires from
or desert areas.(*)                                                                   the positive terminal of one module to the negative of the next module. Figure shows
If you are planning to use the PV modules where the salt water damage may be          modules connected in series .
possible consult with PERLIGHT local agent first to determine an appropriate          7. INSTALLATION
installation method, or to determine whether the installation is possible?            Refer to installation manual of individual models of PV module.
5. TILT ANGLE                                                                         8.ELECTRICAL RATINGS
The title angle of the PV module is the measured between the PV module and a          Refer to installation manual of individual models of PV module.
horizontal ground surface. The PV module generates the maximum output power
when it faces the sun directly.                                                       9. GROUDING
For the standalone systems with a battery where the PV modules are attached to        All PV models must be grounded by
a permanent structure , the tile angle of the PV modules should be determined to      electrical connection of the module
optimize the performance when the sunlight is the scarcest. In general, if the        frames to ground. Please be careful
electric power generation is adequate when the sunlight is the scarcest, then the     in arranging the system ground so
angle chosen should be adequate during the rest of the year. For grid-connected       that the removal of one module from
installations where the PV modules are attached to a permanent structure, it is       the circuit will not interrupt the
recommended to tilt the PV module at the angle equal to the latitude of the           grounding of any other modules.
installation site so that the power generation from the PV module will be optimum      The modules should be grounded
throughout the year.                                                                  to the same electrical point as
                                                                                      described below.
                                                                                                                                                                        4
             GENERAL INSTALLATION MANUAL
           ● ● ● ● ● ●    FOR PERLIGHT PV MODUELS         ● ● ● ● ● ●
Each PV module has a hole on the side frame of either a bolt, nut and washer            of the PV module is 5degrees or more, normal rainfall is sufficient to keep the module
grounding the module to the frame, a ground lug fastened by bolt or screw, or           glass surface clean under most weather conditions. If dirt build-up become excessive,
appropriate screw(hardware not provided).An example of acceptable ground                clean the glass surface only with a soft cloth using water. If cleaning the back of the
connection using a bolt, nut and washer retaining a ground lug is shown in figure       module is required, take utmost care not to damage the back side materials. In order to
3,in a connection of this type, the hardware(such as a toothed locked washer/star       ensure the operation of the system, please check the connection of wiring and the state
washer) must score the frame surface to make positive electrical contact with the       of the jacket of wires every now and then.
frame. The ground wire must be considered within the requirement of local and
regulation at the site of installation.
10.MOUNTING
Please make sure that all the information described in the installation manual is
still valid and proper for your installation. The mounting method has been verified
by PERLIGHT and NOT CERTIFIED by a third party organization.
The approved way to mount PERLIGHT PV modules to a support structure is
using the bolt holes provided as described in the Specifications. Although
PERLIGHT does not specify or warrant frame clips or clamps, using frame clips
(not provided ) or clamps module (not provided ) is also possible when they are
designed for PV modules and with minimum dimensions on the sides of the
module in accordance with the instructions and drawings provided. If using frame
clips or clamps, the modules should be fixed rigidly and there shall be no damage
to the modules by deforming mounting structure against design load. PERLIGHT
does not specify or warrant frame clips. The PERLIGHT module warranty may be
void if customer-selected trame clips which are improper or inadequate with
respect to the module properties(including strength or material)or installation. Note
that if metal clips are used, there must be a path to ground from the clips.(for
instance, using star washers in the clip hardware set). Please review the
descriptions and drawings carefully; not mounting the modules according to one of
these methods may void your warranty. These mounting methods are designed to
allow module loading of 2400pa.
11.MAINTENANCE
The modules are designed for long life require very little maintenance. If the angle