KORYO PYROTECHNICS CO., LTD.
www.kpyro.com
                               KORYO
                               Marine Distress Signals
Rocket Parachute Flare
    USE                                           SPECIFICATIONS
   Pick up a distress signal on the sea          • Size : Φ41ⅹ221㎜
                                                 • Weight : 370g
                                                 • Materials : Resin
                                                 • Ignition Method : Rocket Propulsion
                                                   type of detonate
    CERTIFICATIONS                                MAINTAIN
   Obtained MED                                  • Expiry Period : 3 years
   • Certificate No : MED-MB-1009-10
    FUNCTION                                      PACKING
   • Luminous Color : Vivid red                  • Rocket Parachute Flare
   • Ignition Time : Min. 40 seconds               2 Rounds/1Plastic Box,
   • Luminous Intensity : Min. 30,000 cd           12Plastic Box/1Carton(24Rounds)
   • Altitude : Min. 300m
    OPERATION                                     REFERENCE
   1. Remove top and bottom cap.                 • SOLAS 1999/2000-5 April 2001
   2. Pull bottom ring until it stops and turn   • LSA Code-25 September 1998
      it upwards.                                • Resolution MSC.81(70)-11 December
   3. Hold singal with both hands firmly and       1998
      keep upright. Squeeze top of ring          • 96/98 EC Directive 10 July 2001
      holder with base of thumb, then push
      it for fire.
Red Hand Flare
    USE                                             SPECIFICATIONS
   Pick up a distress signal on the sea            • Size : ø27.1ⅹ172.7㎜
                                                   • Weight : 180g
                                                   • Materials : Stainless steel
                                                   • Ignition Method : Detonator striking
    CERTIFICATIONS                                  MAINTAIN
   Obtained MED                                    • Expiry Period : 3 years
   • Certificate No : MED-MB-1010-10
    FUNCTION                                        PACKING
   • Luminous Color : Vivid red                    • Red Hand Flare
   • Ignition Time : Min. 1 minute                   6 Rounds/1Plastic Box,
   • Luminous Intensity : Min. 15,000 cd             16Plastic Box/1Carton(96Rounds)
    OPERATION                                       REFERENCE
   1. Turn handle to slot and unscrew cap.         • SOLAS 1999/2000-5 April 2001
   2. Pull out ignition-cord, and then ignition.   • LSA Code-25 September 1998
                                                   • Resolution MSC.81(70)-11 December
                                                     1998
                                                   • 96/98 EC Directive 10 July 2001
Buoyant Smoke Signal
    USE                                      SPECIFICATIONS
   Pick up a distress signal on the sea     • Size : ø82ⅹ100㎜
                                            • Weight : 420g
                                            • Materials : Tin coated steel plate
                                            • Ignition Method : Detonator striking
    CERTIFICATIONS                           MAINTAIN
   Obtained MED                             • Expiry Period : 3 years
   • Certificate No : MED-MB-1011-10
    FUNCTION                                 PACKING
   • Smoke Color : Orange                   • Buoyant Smoke Signal
   • Smoke Duration : Min. 3 minutes          1 Round/Pack,
                                              24Pack/1Carton (24Rounds)
    OPERATION                                REFERENCE
   1. Remove safety cap.                    • SOLAS 1999/2000-5 April 2001
   2. Smoke will generate if you draw the   • LSA Code-25 September 1998
      trigger line                          • Resolution MSC.81(70)-11 December
   3. Throw into a sea                        1998
                                            • 96/98 EC Directive 10 July 2001
Self-Activating Smoke Signal
    USE                                             SPECIFICATIONS
   Pick up a distress signal on the sea            • Size : ø118ⅹ240㎜
                                                   • Weight : 2,200g
                                                   • Materials : Tin Coated Steel Plate
                                                   • Ignition Method : Detonator striking
    CERTIFICATIONS                                  MAINTAIN
   Obtained MED                                    • Expiry Period : 3 years
   • Certificate No : MED-MB-1012-12
    FUNCTION                                        PACKING
   • Smoke Color : Orange                          • Self-Activating Smoke Signal
   • Smoke duration : Min. 15 minutes                1Rounds/1Pack,
                                                     6Pack/1Carton(6Rounds)
    OPERATION                                       REFERENCE
   1. The pulling rope on the top should be        • SOLAS 1999/2000-5 April 2001
      fixed to the ship body. and the other        • LSA Code-25 September 1998
      rope on the side should be attached to       • Resolution MSC.81(70)-11 December
      a lifebuoy.                                    1998
   2. Hold it by hand and throw it overboard       • 96/98 EC Directive 10 July 2001
      on the water.
   3. It is automatically ignited, and instantly
      generates a volume of dense orange
      colored smoke for 15 minutes
Light-Smoke Signal
    USE                                              SPECIFICATIONS
   This Light-smoke signal K-52 is combined         • Size : ø188ⅹ86ⅹ490㎜
   type of self activating smoke signal and self-   • Weight : 4,300g(Including bracket 5,100g)
   igniting light, and intended to the lifebuoy     • Materials : Resin+Aluminum
   having arrangement of quick release from         • Lighting Power Source : 1 Lithium 3V
   ship’s navigation bridge at side.                • Ignition Method : Detonator striking
                                                    • Lighting Method : Mercury Switch &
                                                                         Toggle Switch
    CERTIFICATIONS                                   MAINTAIN
   Obtained MED                                     • Expiry Period : 3 years
   • Certificate No : MED-MB-1013-12
    FUNCTION                                         PACKING
   Emission of smoke by self-activation of          • Life-Smoke Signal
   striker igniter by pulling out of activating       2Rounds/1Carton(2Rounds)
   cord on top, and automatic “Light-on” in
   self-up-right position afloat in water sea.
   • Smoke Color : Orange
   • Smoke duration : Min. 15 minutes
   • Light Duration : Min. 2 hours
   • Luminous Intensity : Min. 2 cd
    OPERATION                                        REFERENCE
   With instant separation clip for Lifebuoys.      • SOLAS 1999/2000-5 April 2001
   1. Connect the Lifebuoys with Light-smoke        • LSA Code-25 September 1998
      signals.                                      • Resolution MSC.81(70)-11 December
   2. Light-smoke signals will function               1998
      dropping down with Lifebuoys if you           • 96/98 EC Directive 10 July 2001
      draw the fixed pin of the instant sepa-
      ration clip.
   Without instant separation clip for Lifebuoys.
   1. Connect the Lifebuoys with Light-smoke
      signals.
   2. Light-smoke signal will function if you
      throw Lifebuoys on the sea.
Lifebuoy Self-lgniting Light
     USE                                             SPECIFICATIONS
    Pick up a distress signal on the sea            • Size : ø118.5ⅹ450㎜
                                                    • Weight : 1,260g
                                                    • Materials : Resin
                                                    • Connecting Line : 1.5m
                                                    • Light Power Source : 5 Alkaline battery(LR20)
                                                    • Lighting Method : Mercury switch
     CERTIFICATIONS                                  MAINTAIN
    Obtained MED                                    • Expiry Period : Change the battery once a
    • Certificate No : MED-MB-1003-10                                 year
     FUNCTION                                        PACKING
    • Light Duration : Min. 2 hours                 • Lifebuoy Self-lgniting Light
    • Light Intensity : Min. 2 cd                     1EA/1Carton, 10Carton/1Carton(10Rounds)
     OPERATION                                       REFERENCE
    1. Lock the light bulb to the end after         • SOLAS 1999/2000~5. April. 2001
       opening the cap.                             • LSA Code-25 September. 1998
    2. Lock the cap to the end in the right         • Resolution MSC.81(70)-11. December. 1998
       direction.(The light bulb will turn off if   • Resolution MSC.200(80)-13. May. 2005
       you tilt it.)                                • Resolution MSC.226(82)-8. December. 2006
    3. Keep lifebuoys reversing after connecting    • 96/98 EC Directive-10. July. 2001
       them with lines in the underpart.            • ISO 24408-15. November.2005
    4. The light bulb will turn on automatically
       if it is thrown away on the sea.
                                                     ACCESSORY/BRACKET
                                                    • Specification : ø84.2ⅹ148.2mm
                                                    • Materials : Resin
Lifebuoy Self-lgniting Light (Flash light type)
       USE                                                  SPECIFICATIONS
      Pick up a distress signal on the sea                 • Size : 78.3ⅹ78.3ⅹ170.5㎜
                                                           • Weight : 245g
                                                           • Materials : Resin
                                                           • Connecting Line : 1.5m
                                                           • Light Power Source : 1 Alkaline battery (LR20)
                                                           • Lgnition Method : Mercury switch
       CERTIFICATIONS                                       MAINTAIN
      Obtained MED                                         • Expiry Period : Change the battery once
      • Certificate No : MED-MB-1018-10                                      a year
       FUNCTION                                             PACKING
      • Light Duration : Min. 2 hours                      • Lifebuoy Self-lgniting Light
      • Light Intensity : Min. 2 cd                          1EA/1Carton, 10Carton/1Carton(10Rounds)
       OPERATION                                            REFERENCE
      1. Open the cap and put the battery.                 • SOLAS 1999/2000~5. April. 2001
      2. Lock the cap to the end in the right direction.   • LSA Code-25 September. 1998
         (The light bulb will turn off if you tilt it.)    • Resolution MSC.81(70)-11. December. 1998
      3. Keep lifebuoys reversing after connecting         • Resolution MSC.200(80)-13. May. 2005
         them with lines in the underpart.                 • Resolution MSC.226(82)-8. December. 2006
      4. The light bulb will turn on automatically         • 96/98 EC Directive-10. July. 2001
         if it is thrown away on the sea.                  • ISO 24408-15. November.2005
Line-Throwing Appliance
    USE                                                SPECIFICATIONS
   Line-throwing appliance K-19 should be             • Size : ø183ⅹ333㎜
   used that quickly and accurately rescue of         • Weight : 3,900g
   a vessel or human life at a far-off place.         • Materials : Resin
                                                      • Length of line : 320m(±10%)
                                                      • Propelling Method : Detonator striking
    CERTIFICATIONS                                     MAINTAIN
   Obtained MED                                       • Expiry Period : 3 years
   • Certificate No : MED-MB-1013-10
    FUNCTION                                           PACKING
   • Propelling distance : Min.230m                   • Line-Throwing Appliance
                                                        4Rounds/1Carton(4Rounds)
    OPERATION                                          REFERENCE
   Remove the upper cap and bind firmly up            • SOLAS 1999/2000-5 April 2001
   hall with the line with red band. And point        • LSA Code-25 September 1998
   arrow on unit in the direction of firing and       • Resolution MSC.81(70)-11 December 1998
   then, press the line throwing appliance            • 96/98 EC Directive 10 July 2001
   against your thigh and the remove safety
   pin. And the last, held the body and pull
   trigger in the direction of firing. When
   fulling the trigger, trigger pull the firing pin
   latch in a consequence. Firing pin strikes
   detonator, and after ignited ignition charge.
Line-Throwing Appliance
                                                      SPECIFICATIONS
                                                     • Size :       Case          450ⅹ420.5ⅹ170㎜
                                                                    Projectile            ø42ⅹ375㎜
                                                                    Firing Tube           ø47ⅹ360㎜
                                                                    Life Line           320m(±10%)
                                                     • Weight :     Case                        850g
                                                                    Rocket                    1,000g
                                                                    Firing Tube               1,600g
                                                     • Materials : Case                         Resin
                                                                    Projectile line     Carbon steel
                                                                    Firing Tube            Aluminum
    USE
                                                                    Life Line             Nylon rope
   Line-throwing appliance K-21 should be            • Propelling Type : Rocket propulsion of
   used that quickly and accurately rescue of                            detonator striking
   a vessel or human life at a far-off place.
    CERTIFICATIONS                                    MAINTAIN
   Obtained MED                                      • Expiry Period : 3 years
   • Certificate No : MED-MB-1012-10
    FUNCTION                                          PACKING
   • Propelling distance : Min.230m                  • Line-Throwing Appliance
                                                       1 Set /1Carton
                                                       Rocket                                 4
                                                       Firing Gun                             1
                                                       Life Line                              4
    OPERATION                                          Firing Tube                            1
                                                       Cartridge                              5
   1. After fixed one end of the end of the life       Screw-Driver for cartridge             1
      line that is located bottom of the life line
      box to a ship body, and connected
      upper of it to the rope attached to the
      rocket and the cartridge is loaded to the       REFERENCE
      bottom of the firing tube.                     • SOLAS 1999/2000-5 April 2001
   2. Fix together the prepared firing tube          • LSA Code-25 September 1998
      and firing gun fitting boss in slot of         • Resolution MSC.81(70)-11 December 1998
      rocket and insert the prepared rocket          • 96/98 EC Directive 10 July 2001
      into the firing tube.
   3. When the life line is launched by pulling
      trigger of the K-21, the rocket will
      launch carrying line to the target.
First Aid Kit
                 USE
                For emergency measure of a patient on the sea.
                 SPECIFICATIONS
                • Size : 280ⅹ360㎜
                • Materials : PET+AI+PE
                • Weight : 900g
 Marine Fixed Condensed Aerosol Fire-Extinguishing Systems
Equivalent fixed gas fire extinguishing systems for machinery spaces (aerosol systems)
                                                                  Certificate Authority
                                                                 • KR HELLAS LTD.
                                                                  Certificate No.
                                                                 • MED-MB-3012-11
                                                                  MED Item No.
                                                                 • A.1/3/46
                                                                  Specific Standards
                                                                 • SOLAS 1974 as amended, Regulation Ⅱ-2/10, X/3
                                                                 • IMO Res.MSC.36(63)-(1994 HSC code)7,
                                                                 • IMO Res.MSC.97(73)-(2000 HSC code)7,
                                                                 • IMO Res.MSC.98(73)-(FSS code)5,
                                                                 • IMO MSC.1/Cire.1270
                                                                 ※ MED certified Fire control panel and detectors are used
   Specifications                                                                                               ※ Oil Fire Standard
                          Weight of         Protected                 Diameter      Discharge
   No.    Model                                       Length (mm)                                Operation             Use
                    extinguishing agent(g) volume(㎥)                    (mm)        time (sec)
   1     KF-50S             50              0.65         93.4            54.0          ≒ 7
   2     KF-100S            100             1.30         116.2           71.0         ≒ 11
   3     KF-300S            300             3.89         166.7           92.1         ≒ 11
   4     KF-500S            500             6.49         224.0          116.0         ≒ 14                         Machinery
                                                                                                 Electrically
   5     KF-850S            850             11.03        262.0          137.0         ≒ 14                            Spaces
   6     KF-1500S          1500             30.00        273.0          247.0         ≒ 21
   7     KF-3000S          3000             60.00        335.0          306.0         ≒ 23
   8     KF-6300S          6300            100.00        379.0          415.0         ≒ 20
                                                                                          선박용신호기                   Signce 1976
   로켓낙하산신호                        신호홍염                                발연부신호                                        자기발연부신호
 Rocket Parachute Flare         Red Hand Flare                Buoyant Smoke Signal                         Self-Activating Smoke Signal
                                                         Lifebuoy Self-lgniting Light (Flash light type)   Lifebuoy Self-lgniting (Flash light type)
    조연식신호기                       자기점화등                         자기점화등(점멸식)                                            구명줄발사기
  Light-Smoke Signal      Lifebuoy Self-lgniting Light
    구명줄발사기                       응급의료구                   무인기관실용 자동소화장치                                     무인기관실용 자동소화장치
Line-Throwing Appliance           First Aid Kit
http. www.kpyro.com   e-mail. sales@kpyro.com