Datasheet Mass Intl
Datasheet Mass Intl
Index
Model Page
PG120 Uitility gauges (Size 40, 50, 63 mm) 1
PG121 Uitility gauges (Size 100, 150, 250 mm) 3
GFB Industrial gauges crimp ring type with brass connection 5
GES Industrial gauges crimp ring type compact design 7
GFS Industrial gauges crimp ring type 9
WPS Open front process gauges 11
ZPS Stainless steel process gauges 13
SFS Solid front process gauges 15
TGS Test gauges accuracy 0.5% 17
MGS Master gauges accuracy 0.25% 19
SDS Diaphragm gauges for low pressure measurement 21
D100 Differential pressure gauges bellow type 23
D101 Differential pressure gauges diaphragm type(25 bar) 25
D104 Differential pressure gauges diaphragm type(100 bar) 27
D105 Differential pressure gauges double diaphragm type 29
D201 Differential pressure gauge magnetic piston type 31
DS20 Screwed Diaphragm seal general purpose application 33
DS21 Screwed Diaphragm seal 35
DS50 Screwed Diaphragm seal All welded construction 37
DS51 Screwed Diaphragm seal compact design 39
DS52 Sanatary seal tri-clamp type 40
DS54 Screwed Diaphragm seal for high pressure 41
DF20 Flanged Diaphragm seal 43
DF21 Flanged Diaphragm seal for exocitic material 45
DF50 Flush type flanged diaphragm seal 47
DF52 Diaphragm seals pancake type 49
BMT Bi-metallic temperature gauges 51
MTS Mercury filled temperature gauges 53
GTS Gas filled temperature gauges 55
RTH Resistant temperature detector with head 57
RTW Resistant temperature detector without head 59
TCH Thermocouple with Head 61
Mass product datasheet
TWT Screwed thermowell 63
TWF Flanged thermowell 65
EC Electric contact 67
SY1 Syphon 68
CT1,CT5 Cooling Tower 69
PD1 Pulsation dampener / Snubber 70
PL1 Pressure limiter / Gauge saver 71
GV Gauge valves / Gauge cock 72
NV1 Needle valve 73
2VM 2 valve manifold 75
3VM 3 valve manifold 77
5VM 5 valve manifold 79
Utility pressure gauges
Model PG120
Nominal size 40 mm, 50 mm, 63 mm
Accuracy: Class 2.5 (2.5%)
Features
x Rugged construction
x Protection IP54
x Overload protection 130 %
2
x Standard dial dual scale (psi, kg/cm )
x Dry
Ranges
-30 in. Hg ... 0 psi up to 0 ... 6,000 psi
Applications
Heating and ventilation
Machine and apparatus construction
Air filters and regulators
Valve positioners and compressors
Order information
Size System Execution Process Connection Range Engineering Case Material Options
Material connection orientation units
(40) (B) Tube (D) dry IP54 (02)1/4” NPT (M) 1) (L) Lower -30”/ 01) (psi & kg/cm2) (=) Standard (DA) Dial Marking
40mm phosphor -30”/ 151) Dual scale Steel
bronze, (01)1/8” NPT (M) (C) Centre -30”/ 301) “Hg / psi & case (ON) Neutral, without
(50) socket back -30”/ 601) mmHg / black logo
brass (13)1/4” BSP (M) 1) -30”/ 1001) kg/cm2 finish
50mm (UC) U-clamp
-30”/ 1501)
(S) 316 tube, (12)1/8” BSP (M) -30”/ 2001)
(63) (YX) Stainless (FX) Front panel 1)
316 socket steel 304
63mm
0/ 151) (psi & kg/cm2) case (FW) Surface plate 1)
0/ 201) Dual scale
0/ 30 psi & kg/cm2 (PC) Polycarbonate
0/ 50 cap
0/ 60
0/ 100
(CR) Crimp ring
0/ 150
0/ 2001)
0/ 2501)
0/ 3001)
0/ 4001)
0/ 5001)
0/ 6001)
0/ 8001)
0/ 10001)
0/ 15002)
0/ 20002)
0/ 30002)
0/ 40002)
0/ 50002)
0/ 60002)
1) Not for dial size 40mm 2) not for dial size 40mm, 50mm
How to order
Size Type System Execution Process Connection Range Engineering Filling/Case Option
material connection orientation unit material
2
63 PG120 B D 02 L 0/60 psi & kg/cm = CR
Features
x Rugged construction
x Protection IP54
x Overload protection 130 %
2
x Standard dial dual scale (psi, kg/cm )
x Dry
Ranges
-30 in. Hg ... 0 psi up to 0 ... 10,000 psi
Applications
Heating and ventilation
Machine and apparatus construction
Hydraulic and pneumatic systems
Boiler and refrigeration
Order information
Size System Execution Process Connection Range Engineering Case Material Options
material connection orientation units
(100) (B) Tube (D) dry (04)1/2” NPT (M) 2) (L) Lower -30”/ 0 (psi & kg/cm2) (=) Standard (NH) Tagging wired
100mm bronze, IP54 -30”/ 15 Dual scale Steel case
socket (03)3/8” NPT (M) (C) Centre -30”/ 30 “Hg / psi & black finish (DA) Dial Marking
(150) brass3) back1) -30”/ 60 mmHg / kg/cm2
(02)1/4” NPT (M) -30”/ 100 (ON) Neutral, without
150mm
2) -30”/ 150 logo
(15)1/2” BSP (M) -30”/ 200
(250) (FX) Front panel 1)
250mm (14)3/8” BSP (M) 0/ 10 (psi & kg/cm2)
0/ 15 Dual scale (FW) Surface plate
(13)1/4” BSP (M) 0/ 20 psi & kg/cm2
0/ 30
(16)M20x1.5 (M) 2) 0/ 50
0/ 60
0/ 100
0/ 150
0/ 200
0/ 250
0/ 300
0/ 400
0/ 500
0/ 600
0/ 800
0/ 1000
0/ 1500
0/ 2000
0/ 3000
0/ 4000
0/ 5000
0/ 6000
0/ 8000
0/ 10000
1) Only for dial size 100mm 2) only for dial size 250mm 3) for ranges above 1000 psi tube material SS316
How to order
Size Type System Execution Process Connection Range Engineering Filling/Case Option
material connection orientation unit material
2
100 PG121 B D 02 C 0/60 psi & kg/cm = NH
Features
x Twin o-ring design for leak tight enclosure
x Protection IP65
x Usable to full scale
x Overload protection 130 %
x Measuring tubes SS316 / PB
x Minimized pulsation, Vibration and pointer flittering due to
dampening effect
Ranges
2 2
-1 ... 0 kg/cm up to 0 ... 400 kg/cm
-30 in. Hg ... 0 psi up to 0 ... 6,000 psi
Applications
Power packs
Hydraulic machinery
Pumps
Other vibration applications
Order information
Size Type System Executio Process Connection Range Engineering Filling Options
material n connection orientation units material
(63) GFB (B) Socket (L) IP 65 (04) 1/2” NPT (M)1) (L) Lower -1/ 02) (kg/cm2) (=) No filling (NH) Tagging wired
63 mm Brass, -1/ 0.62)
Tube (03) 3/8” NPT (M) 1)
(C) Center -1/ 1.52) (GV) Silicone (DA) Dial Marking
(100) SS316 2) back -1/ 32)
(02) 1/4” NPT (M) (GR) Glycerin (CS) Dual Scale
100 mm -1/ 52)
-1/ 9 (FX) Front panel
(01) 1/8” NPT (M) -1/ 15
-1/ 24 (FW) Surface plate
(15) 1/2” BSP(M)1)
0/ 12)
(14) 3/8”BSP(M)1) 0/ 1.62) (UF) U-clamp
0/ 2.52)
(13) 1/4” BSP(M) 0/ 42)
0/ 62)
(12) 1/8” BSP(M) 0/ 10
0/ 16
(16) M20x1.5(M)1) 0/ 25
0/ 40
0/ 60
0/ 100
0/ 160
0/ 250 psi and others
Others on request 0/ 400 on request
1) Not for 63mm 2) Tube material Phosphorous Bronze for range below 6 kg/cm2
How to order
Size Type System Execution Process Connection Range Engineering Filling/case Option
material connection orientation unit material
63 GFB B L 02 L 0/16 KG/CM2 = NH
Features
x Rugged stainless steel construction
x Socket and case welded
x Protection IP65
x Overload protection 130 %
x Dry or liquid filled
x Measuring system stainless steel
Ranges
2 2
-1 ... 0 kg/cm up to 0 ... 700 kg/cm
-30 in. Hg ... 0 psi up to 0 ... 10,000 psi
Applications
Power packs
Hydraulic machinery
Pumps
Power plants
Pipelines
Transmission stations
Order information
Size Type System Execution Process Connection Range Engineering Filling liquids Options
material connection orientation units
(100) GES (A) Socket (L) IP 65 (03) 3/8” NPT (M) (L) Lower -1/ 0 (kg/cm2) (=) No filling (NH) Tagging wired
100 mm 304, -1/ 0.6
Tube (02) 1/4” NPT (M) (B) Back -1/ 1.5 (GV) Silicone (CS) Dual Scale
316 -1/ 3
(14) 3/8”BSP(M) (GR) Glycerin (FX) Front panel
-1/ 5
-1/ 9 (FW) Surface plate
(13) 1/4” BSP(M) -1/ 15
-1/ 24 (UF) U-clamp
0/ 1
0/ 1.6
0/ 2.5
0/ 4
0/ 6
0/ 10
0/ 16
0/ 25
0/ 40
0/ 60
0/ 100
0/ 160 and other
0/ 250 equivalent
0/ 400 ranges in PSI,
0/ 600 Bar, kPa, MPa,
etc.
How to order
Size Type System Execution Process Connection Range Engineering Filling liquids Option
material connection orientation unit
100 GES A L 14 L 0/16 KG/CM2 = NH
Features
x Rugged stainless steel construction
x Socket and case welded
x Protection IP65
x Usable to full scale
x Overload protection 130 %
x Dry or liquid filled
x Measuring system stainless steel
Ranges
2 2
-1 ... 0 kg/cm up to 0 ... 1600 kg/cm
-30 in. Hg ... 0 psi up to 0 ... 23,000 psi
Applications
Power packs
Hydraulic machinery
Pumps
Power plants
Pipelines
Transmission stations
Order information
Size Type System Executi Process Connection Range Engineering Filling/case Options
material on connection orientation units material
(63) GFS (A) Socket (L) IP 65 (04) 1/2” NPT (M)1) (L) Lower -1/ 0 (kg/cm2) (=) No filling (NH) Tagging wired
63 mm 304, 1)
-1/ 0.6
Tube (03) 3/8” NPT (M) (B) Back -1/ 1.5 (GV) Silicone (DA) Dial Marking
(100) 3161) -1/ 3
100 mm (02) 1/4” NPT (M) (C) Center -1/ 5 (GR) Glycerin (CS) Dual Scale
2)
back -1/ 9
(S) Socket (01) 1/8” NPT (M) -1/ 15 (GX) Halocarbon (OF) Oil free
316, -1/ 24
Tube (15) 1/2” BSP(M)1) (YW) Case (SG) Safety glass2)
0/ 1
316 material
(14) 3/8”BSP(M)1) 0/ 1.6 (FX) Front panel
316L
0/ 2.5
(1.4404)
(13) 1/4” BSP(M) 0/ 4 (FW) Surface plate
(L) Socket 0/ 6
and (12) 1/8” BSP(M) 0/ 10 (UF) U-clamp
Tube 0/ 16
316L (16) M20x1.5(M) 1)
0/ 25 (ATX) ATEX listed3)
0/ 40
0/ 60
0/ 100
0/ 160
0/ 250
and other
0/ 400 equivalent
0/ 600 ranges in PSI,
0/ 1000 Bar, kPa, MPa,
0/ 16001) etc.
1) Not for 63mm 2) For 63 mm only 3) Safety glass(SG) mandatory for Ex-proof and for 63mm only
How to order
Size Type System Execution Process Connection Range Engineering Filling/case Option
material connection orientation unit material
63 GFS S L 02 L 0/16 KG/CM2 = NH
Features
x Rugged stainless steel construction
x Measuring system stainless steel or Monel
x Socket and case welded
x Protection IP54, IP65, IP66 and IP67
x Usable to full scale
x Overload protection 130 %
x Dry, liquid filled
x Optional contacts
x Optional external Zero Adjustment
Ranges
2 2
-1 ... 0 kg/cm up to 0 ... 2500 kg/cm
-30 in. Hg ... 0 psi up to 0 ... 36,000 psi
Applications
Chemical & petrochemical industries, refineries
Fertilizer, thermal & nuclear power plants
OEM & machine apparatus
Order information
Size Type System Executi Process Connection Range Engineer- Filling/case Options
material on connection orientation ing units material
(63) WPS (S) Socket (D) IP54 (04)1/2” NPT (M)1) (L) Lower -1/ 0 (kg/cm2) (=) Standard (NH) Tagging wired
63mm 316, -1/ 0.6 no filling
Tube (L) IP65 (03)3/8” NPT (M)1) (B) Back -1/ 1.5 (DA) Dial Marking
(100) 316 -1/ 3 (GV) Silicone5)
(R) IP66 (02)1/4” NPT (M) (C) Centre (CS) Dual Scale
100 mm -1/ 5
(L) Socket back 2)
-1/ 9 (GR) Glycerin5) (OF) Oil free
(115) and (N) IP67 (01)1/8” NPT (M) -1/ 15
115mm Tube -1/ 24 (GX) Halocar- (MP) Micrometer
(15)1/2” BSP (M)1) bon5) pointer1)
316L
(150) (P) Socket 0/ 0.61)
150mm (14)3/8” BSP(M)1) (YW) Case (PD) Acrylic glass
and 0/ 1
material (SG) Safety glass
Tube (13)1/4” BSP(M) 0/ 1.6
(250) 316L
Monel1) 0/ 2.5
250mm (1.4404) (FX) Front panel
(12)1/8” BSP(M) 0/ 4
0/ 6 (EC) Contact (FW) Surface plate
(16)M20x1.5(M) 1) 0/ 10 type and
0/ 16 (UF) U-clamp
function
(KQ)1/2” BSPT (M)1) 0/ 25 (see (TU) Throttle screw
0/ 40 EC.1)1)3) 5)
(KR)3/8” BSPT (M)1) 0/ 60 (EZ) External Zero
(KA)1/4” BSPT (M)
0/ 100 adjustment1)6)
0/ 160
0/ 250 (AJ) Calibration 0.5 %
0/ 400 F.S.4)
0/ 600
0/ 1000 (PR) Receiver gauge 1)
0/ 16001) (ATX) ATEX listed 7)
0/ 25001) psi and
others on
request
1) Not for size 63mm 2) For 63mm only 3) For dry gauges only 4) For 150 mm, 250 mm 5) Not for 0.6 kg/cm2 6) not for 250 mm
7) Safety glass (SG) mandatory for Ex-proof and for 63mm only
How to order
Size Type System Execution Process Connection Range Engineering Filling/Case Option
material connection orientation unit material
150 WPS S L 04 L 0/16 KG/CM2 NA NH
Features
x Rugged stainless steel construction
x Socket and case welded
x Protection IP65, IP66 and IP67
x Usable to full scale
x Overload protection 130 %
x Dry, liquid filled
x Optional contacts
x Optional external Zero Adjustment
Ranges
2 2
-1 ... 0 kg/cm up to 0 ... 1000 kg/cm
-30 in. Hg ... 0 psi up to 0 ... 15,000 psi
Applications
Chemical & petrochemical industries, refineries
Fertilizer, thermal & nuclear power plants
OEM & machine apparatus
Order information
Size Type System Execution Process Connection Range Engineering Filling/case Options
material Connection orientation units material
(100) ZPS (S) Socket (L) IP65 (04)1/2” NPT (M) (L) Lower -1/ 0 (kg/cm2) (=) Standard (NH) Tagging wired
100 mm 316, -1/ 0.6 no filling
Tube (R) IP66 (03)3/8” NPT (M) (B) Back -1/ 1.5 (DA) Dial Marking
(115) 316 -1/ 3 (GV) Silicone2)
115mm (N) IP67 (02)1/4” NPT (M) -1/ 5 (CS) Dual Scale
(L) Socket -1/ 9 (GR) Glycerin2)
(150) and (01)1/8” NPT (M) -1/ 15 (OF) Oil free
150mm Tube -1/ 24 (GX) Halocar-
316L
(15)1/2” BSP (M)
0/ 0.6 bon2) (MP) Micrometer
pointer
(14)3/8” BSP(M) 0/ 1
(YW) Case
0/ 1.6 (PD) Acrylic glass
material
(13)1/4” BSP(M) 0/ 2.5
316L
0/ 4 (SG) Safety Glass
(1.4404)
(12)1/8” BSP(M) 0/ 6
0/ 10 (FX) Front panel
(16)M20x1.5(M) 0/ 16
0/ 25 (FW) Surface plate
(KQ)1/2” BSPT (M) 0/ 40
0/ 60 (UF) U-clamp
(KR)3/8” BSPT (M) 0/ 100
0/ 160 (TU) Throttle screw
(KA)1/4” BSPT (M) 0/ 250
0/ 400 (EZ) External Zero
0/ 600 adjustment
psi and others
0/ 1000 on request
1) Specify details 2) Not for 0.6 kg/cm2
How to order
Size Type System Execution Process Connection Range Engineering Filling/Case Option
material connection orientation unit material
100 ZPS S L 04 L 0/16 KG/CM2 = NH
Features
x Solid front type construction
x Rugged stainless steel construction
x Measuring system stainless steel or Monel
x Socket and case welded
x Protection IP54, IP65 and IP66
x Usable to full scale
x Overload protection 130 %
x Dry, liquid filled
x Optional external Zero Adjustment
Ranges
2
-1 ... 0 bar up to 0 ... 1400 kg/cm
-30 in. Hg ... 0 psi up to 0 ... 20,000 psi
Applications
Chemical, petrochemical industry, petroleum refinery
Fertilizer, thermal & nuclear power generation industry
Machine and apparatus construction
Order information
Size Type System Execution Process Connection Range Engineering Filling/Case Options
material connection orientation units material
(100) SFS (S) Socket (D) IP54 (04)1/2” NPT (M) (L) Lower -1/ 0 (kg/cm2) (=) Standard (NH) Tagging wired
100 mm 316, -1/ 0.6 no filling
Tube (L) IP65 (03)3/8” NPT (M) (B) Back2) -1/ 1.5 (DA) Dial Marking
(115) 316 -1/ 3 (GV) Silicone1)
115mm (02)1/4” NPT (M) -1/ 5 (CS) Dual scale
(L) Socket -1/ 9 (GR) Glycerin1)
(150) and (15)1/2” BSP (M) -1/ 15 (OF) Oil free
150mm Tube -1/ 24 (GX) Halocar-
316L (14)3/8” BSP(M) 0/ 0.6 bon1) (MP) Micrometer
(P) Socket 0/ 1 pointer
and (13)1/4” BSP(M) 0/ 1.6 (YW) Case
Tube 0/ 2.5 material (EZ) External Zero
Monel (16)M20x1.5(M) 0/ 4 316L adjustment
0/ 6 (1.4404)
0/ 10 (FX) Front panel
0/ 16 (EC) Contact
0/ 25 type and (FW) Surface plate
0/ 40 function
0/ 60 (see (TU) Throttle screw
0/ 100 EC.1)1)
0/ 160 (AJ) Calibration 0.5 %
0/ 250
F.S.2)
0/ 400
0/ 600
(AV) Anti-Vibration3)
0/ 1000
0/ 1400
psi & others on
Others on request request Others on request
1) Not for range 0.6 kg/cm² 2) For size 150mm and range up to 0/700 kg/cm2 only
3) For pressure ranges ≥ 2.5 kg/cm2 & available with limited options, Halocarbon filling not allowed & consult engineering.
How to order
Size Type System Execution Process Connection Range Engineering Filling/Case Option
material connection orientation unit material
100 SFS S L 04 L 0/16 KG/CM2 = NH
Features
x Rugged stainless steel construction
x Protection IP65
x Usable to full scale
x Overload protection 130 %
x Dry, liquid filled
x Measuring system stainless steel all welded
x Optional external Zero Adjustment
Ranges
2 2
-1 ... 0 kg/cm up to 0 ... 1000 kg/cm
-30 in. Hg ... 0 psi up to 0 ... 15,000 psi
Applications
Chemical & petrochemical industries
Machine and apparatus construction
Food and beverage industries
Pulp and paper industries
Order information
Size Type System Execution Process Connection Range Engineer- Filling/case ma- Options
material connection orientation ing units terial
(150) TGS (S) Socket (=) IP65 (04)1/2” NPT (M) (L) Lower -1/ 0 (kg/cm2) (=) Standard (NH) Tagging wired
150mm 316, -1/ 0.6 no filling
Tube (03)3/8” NPT (M) (B) Back -1/ 1.5 (DA) Dial Marking
(250) 316L -1/ 3 (GV) Silicone
250mm3) (02)1/4” NPT (M) -1/ 5 (CS) Dual Scale
-1/ 9 (GR) Glycerin
(15)1/2” BSP (M) -1/ 15 (OF) Oil free
-1/ 24 (GX) Halocar-
(14)3/8” BSP(M) bon (PD) Acrylic glass
0/ 0.62)
(13)1/4” BSP(M) 0/ 1
(YW) Case ma- (MP) Micrometer
0/ 1.6
terial 316L pointer
(16)M20x1.5(M) 0/ 2.5
0/ 4
(EZ) External Zero
0/ 6
0/ 10 adjustment
0/ 16
0/ 25 (SG) Safety glass
0/ 40
(FX) Front panel
0/ 60
0/ 100 (FW) Surface plate
0/ 160
0/ 250 (UF) U-clamp3)
0/ 400
0/ 600
psi and oth-
(SF) Solid front1)
0/ 1000 ers on re-
quest
1) Not for 250mm 2) Not for liquid filled 3) Not for solid front (SF)
How to order
Size Type System Execution Process Connection Range Engineering Filling/Case Option
material connection orientation unit material
150 TGS S = 04 L 0/16 KG/CM2 = NH
Features
x Rugged stainless steel construction
x Protection IP65
x Usable to full scale
x Easy access for calibration
x Ambient temperature compensation
x Optional external Zero Adjustment
Ranges
2 2
-1 ... 0 kg/cm up to 0 ... 1000 kg/cm
-30 in. Hg ... 0 psi up to 0 ... 15,000 psi
Applications
Test benches
Calibration laboratories
Maintenance and repair shop
Order information
Size Type
System Execution Process Connection Range Engineering Case material Options
material connection orientation units
(150) MGS (A) Socket (=) IP65 (04)1/2” NPT (M) (L) Lower -1/ 0 (kg/cm2) (=) Standard (NH) Tagging wired
150mm 316, -1/ 0.6
Tube (03)3/8” NPT (M) (B) Back -1/ 1.5 (YW) Case mate- (DA) Dial Marking
(250) beryllium -1/ 3 rial 316L
250mm copper (02)1/4” NPT (M) -1/ 5 (CS) Dual Scale
(M) Socket & -1/ 9
Tube (15)1/2” BSP (M) -1/ 15 (OF) Oil free
Monel -1/ 24
(14)3/8” BSP(M) (PD) Acrylic glass
0/ 0.6
(13)1/4” BSP(M) 0/ 1 (MP) Micrometer
0/ 1.6
pointer
(16)M20x1.5(M) 0/ 2.5
0/ 4
(EZ) External Zero
0/ 6
0/ 10 adjustment
0/ 16
0/ 25 (SG) Safety glass
0/ 40
(FX) Front panel
0/ 60
0/ 100 (FW) Surface plate
0/ 160
0/ 250 (UF) U-clamp2)
0/ 400
0/ 600 (SF) Solid front1)
0/ 700
0/ 1000 psi and others
on request
1) Not for 250mm 2) not for solid front (SF)
How to order
Size Type System Execution Process Connection Range Engineering Case material Option
material connection orientation unit
150 MGS A = 04 L 0/16 KG/CM2 = NH
Features
x Stainless steel construction
x Suitable for corrosive environments
x Protection IP54
x Usable to full scale
x Overload protection 130%
Ranges
2
-25 ... 0 mbar up to 0 ... 2,5 kg/cm
-250 ... 0 mmWC up to 0 ... 30 psi
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Food and beverage industry
Pulp and paper industry
Order information
Size Type System Process Rating Facing Range Engineer- Blow out/case Options
material connection ing units material
(100) SDS (S) Diaphragm (04) 1/2” NPT (M) (NA) (T) -250/ 0 (mmWC) (=) Standard (NH) Tagging
100 mm 316L, 2) -400/ 0 without wired
flange 316 (03) 3/8” NPT (M) -600/ 0 blowout
(150) (02) 1/4” NPT (M) 2) -1000/ 0 (CS) Dual scale
150 mm (L) Diaphragm -1600/ 0 (IP) Ingress
316L, (15) 1/2” BSP (M) -2500/ 0 protection (OF) Oil free
flange -4000/ 0 IP65
(14) 3/8” BSP(M) 2) 0/ 250
316L (MP) Micrometer
(13) 1/4” BSP(M) 2) 0/ 400
(RB) Blow out pointer
0/ 600
(SP) Diaphragm (16) M20x1.5(M) 0/ 1000 disc
316L & 0/ 1600 (SG) Safety
flange 316, ANSI Flanged (150) 150 lbs (FF) Flat 0/ 2500 (YW) Case glass
PTFE face 1) 0/ 4000 material
protected (05) 1/2” (300) 300 lbs (RF) Raised
316L (DA) Dial
(07) 3/4” (600) 600 lbs face 1) -1/ 0 (1.4404) marking
-1/ 1,5 (kg/cm2)
(10) 1” 0/ 0,6
(15) 1 ½” 0/ 1
0/ 1,6
(20) 2” 0/ 2,5
DIN Flanged (PN10)
(DN15) (PN16)
(DN25) (PN25)
(DN40)
(DN50)
psi and others
on request
1) The DIN-flange facing depends on nominal size and nominal pressure 2) Not for system material (SP)
How to order
Size Type System Process Rating Facing Range Engineering Filling/Case Option
material connection unit material
100 SDS S 04 NA T 0/400 MMWC = NH
Features
x Stainless steel case and wetted parts
x Static pressure 10 times of the range
x Protection IP65
x High corrosive resistance
x Dry or liquid filled
Ranges
0 ... 2500 mmWC up to 0 ... 10 kg/cm2
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Food and beverage industry
Pulp and paper industry
Order information
Size Type
System Execution Process Connection Range Engineer- Filling/case Options
material connection orientation ing units material
(150) D100 (S) 316L (L) IP65 (25) 1/4” NPT (F) (L) Lower 0/2500 (mmWC) (=) Standard no (NH) Tagging wired
150mm process (N) 90° 0/4000 filling
connecti (50) 1/2” NPT (F) (DA) Dial marking
Lower
on and 0/ 0,6 (kg/cm2) (GV) Silicone
bellow (04)1/2” NPT (M) 0/ 1 (CS) Dual scale
(B) Back (GR) Glycerin
0/ 1,6
(03)3/8” NPT (M) 0/ 2,5 (OF) Oil free
0/ 4 (GX) Halocarbon
(02)1/4” NPT (M) (MP) Micrometer pointer
0/ 6
(YW) Case
(15)1/2” BSP (M) 0/ 10 (FX) Front panel
material
316L
(14)3/8” BSP(M) (FW) Surface plate
compound
ranges on
request
1) Specify details
How to order
Size Type System Execution Process Connection Range Engineering Filling/Case Option
material connection orientation unit material
150 D100 S L 04 L 0/4000 MMWC = NH
Features
x Stainless steel case and wetted parts
x Static pressure 25 bar
x Protection IP65
x Dry or liquid filled
Ranges
0 ... 600 mmWC up to 0 ... 2.5 kg/cm2
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Food and beverage industry
Pulp and paper industry
Order information
Size Type System Execution Process Connection Range Engineer- Filling/Case Options
material Connection orientation ing units material
(100) D101 (S) Pressure (L) IP65 (02T) 1/4” NPT (F) (L) Lower 0/ 600 (mmWC) (=) Standard (NH) Tagging wired
100 mm chamber 0/ 1000 no filling
316 and (04T) 1/2” NPT (F) 0/ 1600 (DA) Dial Marking
(115) diaphragm 0/ 2500 (GV) Silicone
115mm 316L (04) 1/2” NPT (M) 0/ 4000 (CS) Dual Scale
0/ 5000 (GR) Glycerin
(150) (03) 3/8” NPT (M) (OF) Oil free
150mm 0/ 0,6 (kg/cm2) (GX) Halocar-
(02) 1/4” NPT (M) bon (MP) Micrometer
0/ 1
pointer
(15) 1/2” BSP (M) 0/ 1,6
(YW) Case
0/ 2,5 (PD) Acrylic glass
material
(14) 3/8” BSP(M) 316L
(FW) Wall mounting
(13) 1/4” BSP(M) bracket
(16) M20x1.5(M) (TM) 2” pipe mounting
(AL) Calibration
1.6%1)
psi and
Standard (02T) others others on
through adaptor request
1) Consult Engineering, limited to certain ranges.
How to order
Size Type System Execution Process Connection Range Engineering Filling/Case Option
material connection orientation unit material
100 D101 S L 02T L 0/600 mmWC = NH
Features
x Stainless steel case and wetted parts
2
x Max static pressure 100 kg/cm
x High corrosive resistance
x Dry or liquid filled
x IP65
Ranges
2
0 ... 1000 mmWC up to 0 ... 25 kg/cm
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Food and beverage industry
Pulp and paper industry
Order information
Size System Execution Process Connection Range Engineer- Filling/case/ Options
material connection orientation ing unit contacts
(100) (S) Pressure (L) IP65 (02) 1/4 NPT (M) (L) Lower 0/10002) (mmWC) (=) Standard (NH) Tagging wired
100 mm chamber 0/1600 no filling
316L & (04) 1/2 NPT (M) 0/2500 (CS) Dual scale
(150) Diaphragm 0/4000 (GV) Silicone
(DA) Dial marking
150 mm ≤2.5 bar (13) 1/4 BSP (M)
2
316L 0/ 0,6 (kg/cm ) (GR) Glycerin
(AN) Calibration 1 %1)
> 2.5 bar (15) 1/2 BSP (M) 0/ 1
Duratherm 0/ 1,6 (YW) Case
(FX) Front panel
(02T) 1/4 NPT (F) 0/ 2,5 material
0/ 4 316 (FW) Surface plate
0/ 6
0/ 10 (TM) 2" pipe mounting
0/ 16 psi and bracket
others on
0/ 25 request
Order example
Size Type System Execution Process Connection Range Engineering Filling/case/ Option
material connection orientation unit contacts
100 D104 S L 02T L 0/2500 mmWC = NH
Features
x Stainless steel case and wetted parts
2
x Max static pressure 400 kg/cm , one side load permitted
x Chamber purge and bleed connection available
x High corrosive resistance
x Dry or liquid filled
x Dual diaphragm, solid front not required
x IP65
Ranges
2
0 ... 250 mmWC up to 0 ... 25 kg/cm
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Food and beverage industry
Pulp and paper industry
Order information
Size Type System Execu- Process Connection Range Engineer- Filling/case/ Options
material tion connection orientation ing unit contacts
(100) D105 (S) Pressure (L) IP65 (02) ¼” NPT (M) (L) Lower 0/2501) (mmWC) (=) Standard (NH) Tagging wired
100 mm chamber 0/400 no filling
316L (1.4404) (04) ½” NPT (M) 0/ 600 (6B) Oxygen service
(150) Diaphragm 0/1000 (GV) Silicone
(CS) Dual scale
150 mm 316L / 316 Ti (13) ¼” BSP (M) 0/16001)
0/2500 (GR) Glycerin (DA) Dial marking
(15) ½” BSP (M) 0/4000
(YW) Case (EZ) External zero
(02T) ¼” NPT (F) 0/ 0,6 (kg/cm2) material adjustment
0/ 1 316
0/ 1,6 (TM) 2" pipe mounting
0/ 2,5 bracket
0/ 4
(PN100) Static pressure
0/ 6
100 bar
0/ 10
0/ 16 (PN250) Static pressure
0/ 25 250 bar2)
psi and others (PN400) Static pressure
others on request on request 400 bar2)
1) Dial arc shall be 180° 2) only with ranges ≥1600 mmWC
Order example
Size Type System Execution Process Connection Range Engineering Filling/case/ Option
material connection orientation unit contacts
150 D105 S L 04 L 0/600 mmWC = NH
Features
x Stainless steel case and several wetted parts
x Static pressure up to 200 bar
x Protection IP65
x Smooth pointer motion
x Dry or liquid filled
x Magnetic coupling, solid front not required
Ranges
0 … 0,5 bar up to 0 ... 10 bar
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Filters, Hydraulic systems
Water treatment
Order information
Size Type Body Execution Process Connection Range Engineer- Filling/case/ Options
connection orientation ing units contacts
(100) D201 (F) Body (L) IP65 (02T)1/4” NPT (F) (S) In-line 0/ 0,5 KG/CM2 (=) Standard (NH) Tagging wired
100 mm Aluminum standa 0/ 1 no filling
rd case (13T)1/4” BSP(F) (L) Lower 0/ 1,6 (CS) Dual scale
(A) Body Brass 0/ 2 (GR) Glycerin
(150) (02)1/4” NPT (M) (B) Back 0/ 2,5 (DA) Dial marking
150 mm (S) Body 316 0/ 4
(13)1/4” BSP(M) 0/ 6 (SG) Safety glass
0/ 10
(FX) Front Panel
Order example
Size Type Body Execution Process Connection Range Engineering Filling/case/ Options
connection orientation unit contacts
100 D201 S L 02T S 0/1 KG/CM2 = NH
Features
x Metal diaphragms with Teflon gasket
x Interchangeable components
x Removable top and bottom housing
x Variety of wetted parts materials
Ranges
15 psi up to 1000 psi
2 2
1 kg/cm up to 70 kg/cm
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Offshore installations
Pulp and paper industry
Waste water treatment
Order information
Process Type Diaphragm Bottom housing Instrument Filling fluid Options
connection material connection
(06) 1” NPT(M) DS20 (S) 316L (S) 316 (14T) 3/8” (CG) Glycerin (NH) Tagging wired
BSP (F) (direct mounted,
(05) 3/4” NPT(M) (SP) 316L with (L) 316L -18/204 °C) (OF) Oil free (only filled with
teflon (04T) 1/2” halocarbon)
(CK) Silicone
(04) 1/2” NPT(M) protection1) (SP) 316 with teflon NPT (F) (direct mounted or with
lined 1)3) (YT) Stainless steel 316 top
capillary, -40/315 °C)
(03) 3/8” NPT(M) (SJ) 316L with housing
1)2)
teflon (PP) Polypropylene (CF) Halocarbon
(02) 1/4” NPT(M) Coating1) (direct mounted or with (SE) Stainless steel clamp
1)2)
(V) PVC capillary, -56/149 °C) rings
(18) 1” BSP(M) (H) Hasteloy-
(H) Hasteloy-C276 (HA) Syltherm 800 (PU) Flushing connection 1/4”
C276
(17) 3/4” BSP(M) (direct mounted or with
capillary, -40/400 °C)
NPT (F)5)
(15) 1/2” BSP(M) (GZ) Vegetable oil (CA) Stainless steel armored
(direct mounted or with capillary 4)
(14) 3/8” BSP(M) capillary, 0/120 °C)
(CP) Stainless steel armored
(13) 1/4” BSP(M) capillary with PVC
sleeving 4)
(16) M20x1.5(M)
(06T) 1 NPT(F)
Features
x Removable diaphragm seal capsule
x Interchangeable components
x Removable top and bottom housing
x Variety of wetted parts materials
Ranges
15 psi up to 1,500 psi
2 2
1 kg/cm up to 100 kg/cm
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Offshore installations
Pulp and paper industry
Waste water treatment
Order information
Process Type Diaphragm Bottom housing Instrument Filling fluid Options
connection material connection
(06) 1” NPT(M) DS21 (S) 316L (S) 316 (14T) 3/8 BSP (F) (CG) Glycerin (NH) Tagging wired
(direct mounted,
(05) 3/4” NPT(M) (C) 304L (L) 316L (04T) 1/2” NPT (F) -18/204 °C) (OF) Oil free (only filled with
halocarbon)
(04) 1/2” NPT(M) (D) Carpenter (SP) 316 with teflon (CK) Silicone
(direct mounted or with (YT) Stainless steel 316 top
20 lined 1)3) capillary, -40/315 °C)
(03) 3/8” NPT(M) housing
(G) Hastelloy B (PP) Polypropylene 2) (CF) Halocarbon
(02) 1/4” NPT(M) (direct mounted or with (SE) Stainless steel clamp
2)
(H) Hastelloy C (V) PVC capillary, -56/149 °C) rings
(18) 1” BSP(M)
(N) Nickel (H) Hastelloy C (HA) Syltherm 800 (PU) Flushing connection
(17) 3/4” BSP(M) (direct mounted or with
capillary, -40/400 °C)
1/4” NPT (F)5)
(P) K-Monel (M) Monel 400
(15) 1/2” BSP(M) (GZ) Vegetable oil (CA) Stainless steel armored
(U) Tantalum (direct mounted or with capillary 4)
(14) 3/8” BSP(M) capillary, 0/120 °C)
(CP) Stainless steel armored
(13) 1/4” BSP(M) capillary with PVC
sleeving 4)
(16) M20x1.5(M)
(06T) 1 NPT(F)
How to order
Process Type Diaphragm Bottom housing Instrument Filling fluid Option
connection material connection
04 DS21 S S 14T CK CA1000
Features
x Metal diaphragms with Teflon gasket
x Interchangeable components
x Removable top and bottom housing
x Variety of wetted parts materials
Ranges
15 psi up to 3,500 psi
2 2
1 kg/cm up to 250 kg/cm
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Offshore installations
Pulp and paper industry
Waste water treatment
Order information
Process Type Diaphragm Housing Instrument Filling fluid Options
connection material connection
(06) 1” NPT(M) DS50 (S) 316L (S) 316 (14T) 3/8” BSP (CG) Glycerin (NH) Tagging wired
(F) (direct mounted,
(05) 3/4” NPT(M) (H) Hasteloy-C276 (L) 316L -18/204 °C) (HP) High Pressure Ring
(04T) 1/2” NPT
(04) 1/2” NPT(M) (H) Hasteloy-C276 (CK) Silicone (OF) Oil free
(F) (direct mounted or with
(only filled with halocarbon)
capillary, -40/315 °C)
(03) 3/8” NPT(M)
(CF) Halocarbon (PU) Flushing connection
(02) 1/4” NPT(M) (direct mounted or with 1/4” NPT (F)
capillary, -56/149 °C)
(18) 1” BSP(M) (CA) Stainless steel
(HA) Syltherm 800 armored capillary 1)
(17) 3/4” BSP(M) (direct mounted or with
capillary, -40/400 °C)
(CP) Stainless steel
(15) 1/2” BSP(M) (GZ) Vegetable oil armored capillary
(direct mounted or with with PVC sleeving 1)
(14) 3/8” BSP(M) capillary, 0/120 °C)
(16) M20x1.5(M)
(06T) 1 NPT(F)
How to order
Process Type Diaphragm Housing Instrument Filling fluid Option
connection material connection
04 DS20 S S 14T CK CA1000
General dimensions in mm
Order information
Process Type Diaphragm Housing Instrument Filling fluid Options
connection material connection
(13) 1/4” BSP(M) DS51 (S) 316L (S) 316 (13T) 1/4” BSP(F) (CG) Glycerin (OF) Oil free (only filled with
(CK) Silicone halocarbon)
(02) 1/4” NPT(M) (H) Hasteloy-C276 (L) 316L (CF) Halocarbon
(HA) Syltherm 800
(H) Hasteloy- (GZ) Vegetable oil
C276
How to order
Process Type Diaphragm Housing Instrument Filling fluid Option
connection material connection
02 DS51 S S 13T CK OF
General dimensions in mm
Order information
Process Type Diaphragm and Instrument Filling fluid Options
connection top housing connection
(15) 1 1/2” Tri-clamp DS52 (S) 316L (13T) 1/4” BSP(F) (CG) Glycerin (NH) Tagging marked
(direct mounted,
(20) 2” Tri-clamp -18/150 °C) (C) Clamp
(GZ) Vegetable oil (G) Gasket
(direct mounted,
0/120 °C)
(PE) Electro polishing
others on request
How to order
Process Type Diaphragm and Instrument Filling fluid Option
connection top housing connection
15 DS52 S 13T GZ NH
Features
x All welded metal construction
x No gaskets or bolts
x All material stainless steel
Ranges
1500 psi up to 6000 psi
2 2
100 kg/cm up to 400 kg/cm
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Power station
Order information
Process Type Diaphragm Housing Instrument Filling fluid Option
connection material connection
(05) 3/4” NPT(M) DS54 (S) 316L (S) 316 (14T) 3/8” BSP(F) (CG) Glycerin (NH) Tagging wired
(direct mounted,
(04) 1/2” NPT(M) (H)Hasteloy- (L) 316L -18/204 °C) (OF) Oil free
C276 (only filled with
(03) 3/8” NPT(M) (H) Hasteloy-C276 (CK) Silicone halocarbon)
(direct mounted or with
capillary, -40/315 °C) (PU) Flushing
(02) 1/4” NPT(M)
connection 1/4”
(GZ) Vegetable oil
(16) M20x1.5(M) (direct mounted, NPT (F)
0/120 °C)
(17) 3/4” BSP(M) (CA) Stainless steel
(CF) Halocarbon armored capillary 1)
(direct mounted or with
(15) 1/2” BSP(M) capillary, -56/149 °C)
(CP) Stainless steel
(14) 3/8” BSP(M) (HA) Syltherm 800 armored capillary
(direct mounted or with with PVC sleeving
1)
(13) 1/4” BSP(M) capillary, -40/400 °C)
How to order
Process Type Diaphragm Housing Instrument Filling fluid Option
connection material connection
02 DS54 S S 14T CK NH
Features
x Metal diaphragms with Teflon gasket
x Removable top and bottom housing
x Variety of wetted parts materials
Pressure rating
From 150 lbs up to 1500 lbs
From PN10 up to PN100
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Offshore installations
Pulp and paper industry
Waste water treatment
Order information
Process Type Diaphragm Bottom Instrument Rating Flange Filling fluid Options
connection housing connection facing
material
ANSI Flanged DF20 (S) 316L (S) 316 (14T) 3/8 ANSI (FF) Flat (CG) Glycerin (NH) Tagging wired
BSP(F) face 2) (direct mounted,
(05) 1/2” (SP) 316L with (L) 316L (150) 150 lbs -18/204 °C) (OF) Oil free
(only filled with
teflon (04T) 1/2” (RF) Raised
(07) 3/4” (300) 300 lbs (CK) Silicone halocarbon)
protection1) (SP) 316 with NPT(F) face 2) (direct mounted
(10) 1” teflon (600) 600 lbs or with capillary, - (YT) Stainless steel
1)
(SJ) 316L with lined (RTJ) Ring 40/315 °C) 316
(15) 1 ½” teflon (900) 900 lbs joint top housing
1) 2) (CF) Halocarbon
Coating (PP)Polypropyl type
(20) 2” ene 3) (1500) 1500 (direct mounted (SE) Stainless steel
lbs or with capillary, -
(H) Hasteloy- clamp rings
(30) 3” 3) 56/149 °C)
C276 (V) PVC
(SR4) Spacer ring with
DIN Flanged DIN (HA) Syltherm 800
(direct mounted 1/2” NPT
or with capillary, - flushing5)
(DN15) (PN10) 40/400 °C)
(SR2) Spacer ring with
(DN25) (PN16)
(GZ) Vegetable oil 1/4” NPT
(DN40) (PN25) (direct mounted flushing5)
or with capillary,
0/120 °C)
(DN50) (PN40) (CA) Stainless steel
armored capillary
(DN80) (PN64) 4)
How to order
Process Type Diaphragm Bottom housing Instrument Filling fluid Option
connection capsule material material connection
04 DF20 S S 14T CK CA1000
Features
x Removable diaphragm seal capsule
x Metal diaphragms with Teflon gasket
x Removable top and bottom housing
x Variety of wetted parts materials
Pressure rating
From 150 lbs up to 1500 lbs
From PN6 up to PN100
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Offshore installations
Pulp and paper industry
Waste water treatment
Order information
Process Type Diaphragm Bottom Instrument Rating Flange Filling fluid Options
connecti housing connection facing
on material
ANSI DF21 (S) 316L (S) 316 (14T) 3/8” ANSI (FF) Flat (CG) Glycerin (NH) Tagging wired
Flanged BSP(F) face 2) (direct mounted,
(C) 304L (L) 316L (150) 150 lbs -18/204 °C) (OF) Oil free
(05) 1/2” (only filled with
(04T) 1/2” (300) 300 lbs (RF) Raised
(CK) Silicone halocarbon)
(07) 3/4”
(D) Carpenter 20 (SP) 316 with NPT(F) face 2) (direct mounted
teflon (600) 600 lbs or with capillary, (YT) Stainless steel
(10) 1” (G) Hastelloy B lined1) (RTJ) Ring -40/315 °C) 316
(900) 900 lbs joint top housing
(15) 1 (H) Hastelloy C (PP)Polypropyl type 2) (CF) Halocarbon
½” ene 3) (1500) 1500 (direct mounted (SE) Stainless steel
(N) Nickel lbs or with capillary,
-56/149 °C)
clamp rings
(20) 2” (V) PVC 3)
(DN50)
(PN64) (CP) Stainless steel
(DN80) armored capillary
(PN100)
with PVC sleeving
4)
How to order
Process Type Diaphragm Bottom housing Instrument Rating Flange facing Filling fluid Option
connection capsule material material connection
15 DF21 S S 14T 300 RF CK CA1000
Features
x Welded diaphragm seal
x Variety of wetted parts material
x Filling port in the upper housing
x Suitable for pressure gauges, switches and transmitters
Size
1 ½”, 2” & 3” ASME/ANSI
DN40, DN50 & DN80
Pressure Rating
From 150 lbs up to 2500 lbs
From PN10 up to PN160
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Offshore installations
Pulp and paper industry
Order information
Process Type Diaphragm Flange mate- Instrument Flange Flange Filling fluid Options
Size rial connection Rating Facing
ANSI DF50 (S) 316L (S) 316 (14T) 3/8 ANSI (RF) Raised (CG) Glycerin (NH) Tagging wired
Flanged BSP(F) face2) (direct mounted,
(SJ) 316L with (L) 316L (150) 150 lbs -18/204 °C) (OF) Oil free (only filled with
(15)1½” halocarbon)
Teflon (300) 300 lbs (FF) Flat 2) (CK) Silicone
(20)2” Coating1) (SJ) 316 with face (direct mounted or (CA) Stainless steel
PTFE (600) 600 lbs with capillary, armored capillary 3)
(30)3” (H) Hasteloy- coating1) -40/315 °C)
C276 (900) 900 lbs (CP) Stainless steel
(H) Hasteloy- (CF) Halocarbon armored capillary
(1500) 1500 (direct mounted or
C276
with capillary,
with PVC sleeving 3)
lbs
-56/149 °C)
(2500) 2500
lbs (HA) Syltherm 800
(direct mounted or
with capillary,
DIN DIN -40/400 °C)
Flanged
(PN10) (GZ) Vegetable oil
(DN40) (direct mounted or
(PN16) with capillary,
(DN50) 0/120 °C)
(PN25)
(DN80)
(PN40)
(PN64)
(PN100)
3) Max length 30m, specify
(PN160) length in mm
others on request others on request EG. CP1000 = CP with 1m
1) Restricted to temperature 200 °C 2) The DIN-flange facing depends on nominal size and nominal pressure
How to order
Process Type Wetted Flange Instrument Flange Flange Filling fluid Options
Size Parts material connection rating facing
20 DF50 S S 14T 150 RF CK CA1000
Features
x Wafer “pancake” type construction
x Flushed diaphragm
x Variety of wetted parts materials
x Suitable for slurry & high viscous service
Size
2” to 5” ASME/ANSI
DN50 to DN125
Applications
Chemical and petrochemical industry
Offshore installations
Pulp and paper industry
Order information
Process Type Wetted Parts Instrument Backup Flange Backup Flange Filling fluid Options
Size connection Rating Material
ANSI DF52 (S) 316 (14T) 3/8” ANSI (NA) No backup (CG) Glycerin (NH) Tagging wired
Flanged BSP(F) flange (direct mounted,
(L) 316L (NA) No backup -18/204 °C) (OF) Oil free (only filled with
(20) 2” flange (C) SS 304 halocarbon)
(SJ) 316 with (CK) Silicone
(30) 3” (150) 150 lbs (S) SS 316 (direct mounted or (SR4) Spacer ring with
teflon with capillary, - 1/2” NPT flushing3)
(40) 4” coating1) (300) 300 lbs (CS) Carbon steel 40/315 °C)
(SR2) Spacer ring with
(50) 5” (SG) 316 with (600) 600 lbs (CF) Halocarbon 1/4” NPT flushing3)
GOLD (direct mounted or
(900) 900 lbs with capillary, - (CA) Stainless steel
coating 56/149 °C)
armored capillary 2)
(1500) 1500 lbs
(H) Hastelloy - (HA) Syltherm 800 (CP) Stainless steel
DIN C276 DIN (direct mounted or
with capillary, - armored capillary
Flanged 40/400 °C) with PVC sleeving
(M) Monel (NA) No backup 2)
(DN50) flange (GZ) Vegetable oil
(direct mounted or
(DN80) (PN10) with capillary, 0/120
°C)
(DN100) (PN16)
(DN125) (PN25)
(PN40)
(PN64)
(PN100)
2) Max length 30m, specify
length in mm
others on request others on request others on request EG. CP1000 = CP with 1m
1) Restricted to temperature 200 °C 3) Not for (SJ) & (SG)
How to order
Process Type Wetted Parts Instrument Backup flange Backup flange Filling fluid Options
Size connection rating material
30 DF52 S 14T 300 CS CK CA1000
Features
x Rugged stainless steel construction
x Fast response
x Protection IP65
x External zero adjustment
x Dry or liquid filled
x Silicone damped coil
Ranges
-50 ... 50 °C up to 0 ... 600 °C
-80 ... 120 °F up to 30 ... 1100 °F
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Food and beverage industry
Pulp and paper industry
Order information
Size Stem Filling Process connection Connection Stem Range Engineer- Options
diameter orientation length ing unit
(63) (06) 6 mm (=) Standard (40) Plain (75) Adjustable (L) Lower2) 63 to 0 / 50 °C (NH) Tagging
63mm (no filling) (60) Fixed 1/2 union 1 1000 mm 0 / 60 wired
(08) 8 mm BSP (M) (R) Back (for minimum 0 / 80
(100) NPT (M) length refer (DA) Dial mark-
(L) Liquid filled 0 / 100
(61) Fixed 1/2 (76) Adjustable (E) Every above table)
100 mm (10) 10 mm with silicone 0 / 120 ing
union 1/2 angle
max. up to BSP (M) 0 / 150
(115) NPT (F) (CS) Dual scale
(12) 12 mm 300 °C (70) Adjustable 0 / 160
115 mm (not for lower (77) Adjustable 0 / 200
connection, ambi- union 1/2 (SG) Safety
ent temperature NPT (M) union 1/2 0 / 250
(150) BSP (F) 0 / 300 glass
maximum 65 °C)
150mm (71) Adjustable 0 / 400
(90) Adjustable (YW) 316L hous-
union 1/2 0 / 500
BSP (M) union ing
M20X1.5 0 / 550
(72) Adjustable (110) Adjustable 0 / 600 (EZ) External
union 3/4 union 1/4 zero ad-
NPT (M) NPT (M) justment1)
-10/ 50
(73) Adjustable (112)Adjustable -10/ 110
union 3/4 union 3/8
BSP (M) -20/ 40
BSP (M) -20/ 60
(113) Adjustable
(74) Adjustable union 1/4 -20/ 180
union 1 BSP (M) -30/ 50
NPT (M) -30/ 70
-40/ 40
-40/ 60
-40/ 160
Others on
request
1) For size 100mm, 115 mm and 150mm only, and not for connection orientation Lower. 2) Not for size 63mm
How to order
Size Type Stem Filling Process Connection Stem Range Engineering Option
diameter connection orientation length Unit
100 BMT 12 = 70 E 150 0/200 C NH
Features
x Rugged stainless steel construction
x Fast response
x Protection IP65
x High repeatability and small hysteresis
x Dry or liquid filled
x Rigid stem or bulb with capillary
Ranges
-38 ... 50 °C up to 0 ... 600 °C
-35 ... 120 °F up to 30 ... 1100 °F
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Food and beverage industry
Pulp and paper industry
Order information
Size Bulb Length of Length of Process Connection Connection Range Engineer- Options
diameter bulb/stem capillary connection size orientation ing units
(100) (06) 6 mm 115 to (R) Rigid (T) Turning nut (50) 1/2” BSP (L) Lower 0/ 60 °C (NH) Tagging wired
100 mm 4000 mm2) stem 0/ 80
(08) 8 mm (CS2) Adjustable (75) 3/4” BSP (B) Back 0/ 100 (DA) Dial marking
(150) (A) Capillary union 0/ 120 (CS) Dual scale
150mm (10) 10 mm SS armored1) connection (10) 1” BSP (E1) Every 0/ 160
sliding on angle 0/ 200 (SG) Safety glass
(12) 12 mm (P) Capillary capillary (50N) 1/2” NPT 0/ 250
0/ 300 (MP) Micro pointer
SS armored
with PVC (CS3) Adjustable (75N) 3/4” NPT 0/ 400 (FX) Front panel
covering1) union 0/ 500
connection (10N) 1” NPT 0/ 600 (FW) Surface plate
sliding on
(UF) U-clamp
stem (M20) M20x1.5 -10/ 50
-10/ 110 (TM) 2" pipe
(M32) M32x2 -20/ 40 mounting
-20/ 60 bracket
-20/ 100
-20/ 120 (EC) Contact type
-20/ 180 and function
-30/ 70 (see EC.1)
-30/ 50
(GV) Silicon (max.
-30/ 70
up to 300˚C)
-30/ 170
-38/ 50 (YW) 316L housing
1) Max length
30m, specify
length in m °F and dual
others on EG. A1.5 =A scale on other options on request
request with 1.5m others on request others on request request
2) Minimum stem length depends on stem diameter refer table “T1”
How to order
Size Type Bulb Length of Length of Process Connection Connection Range Engineering Options
diameter bulb/stem capillary connection size orientation unit
100 MTS 08 125 R CS2 50N L 0/100 C FW
Features
x Rugged stainless steel construction
x Fast response
x Protection IP65
x High repeatability and small hysteresis
x Dry or liquid filled
x Rigid stem or bulb with capillary
Ranges
-50 ... 50 °C up to 0 ... 600 °C
-60 ... 120 °F up to 30 ... 1100 °F
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Food and beverage industry
Pulp and paper industry
Order information
Size Bulb Length of Length of Process Connection Connection Range Engineer Options
diameter bulb/stem capillary connection size orientation ing units
(100) (06) 6 mm 115 to (R) Rigid (T) Turning (50) 1/2” BSP (L) Lower 0/ 60 °C (NH) Tagging wired
100 mm 4000 mm2) stem nut 0/ 80
(08) 8 mm (75) 3/4” BSP (B) Back 0/ 100 (DA) Dial marking
(115) (A) Capillary (CS2) Adjustable 0/ 120 (CS) Dual scale
115mm (10) 10 mm SS armored1) union (10) 1” BSP (E1) Every 0/ 160
connection angle 0/ 200 (SG) Safety glass
(150) (12) 12 mm sliding on (50N) 1/2” NPT 0/ 250
150mm (P) Capillary (MP) Micro pointer
SS armored capillary 0/ 300
with PVC (75N) 3/4” NPT 0/ 400 (FX) Front panel
covering1) (CS3) Adjustable 0/ 500
union (10N) 1” NPT 0/ 600 (FW) Surface plate
connection
(UF) U-clamp
sliding on (M20) M20x1.5 -10/ 50
stem -10/ 110 (TM) 2" pipe
(M32) M32x2 -20/ 40 mounting
-20/ 100 bracket
-20/ 120
-20/ 180 (EC) Contact type
-30/ 50 and function
-30/ 70 (see EC.1)
-30/ 170
(GR) Glycerin (max.
-40/ 40
up to 100˚C)
-40/ 60
-40/ 160 (GV) Silicon (max.
-50/ 50 up to 300˚C)
(YW) 316L housing
1) Max length
30m, specify
length in m °F and dual
EG. A1.5 =A scale on other options on request
with 1.5m others on request others on request request
2) Minimum stem length depends on stem diameter refer above table
How to order
Size Type Bulb Length of Length of Process Connection Connection Range Engineering Options
diameter bulb/stem capillary connection size orientation unit
100 GTS 08 125 R CS3 50N L 0/100 °C FW
Features
x High stability sensor
x Mineral insulated for flexibility and durability
x General purpose with spring loaded sensor
x Available with weather proof and explosion proof head
x Custom designs for specific applications
Ranges
-200 up to 600 °C
-325 up to 1100 °F
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Pharmaceuticals, Dairy & Food process industry
Pulp and paper industry
Order information
Head Type Ele- Element Accuracy Sheath Sheath Sheath Process Connection Electrical connec- Options
ment type class material diameter length connection Type tion
th
(E) Compact Pt100 (S2) Simplex (1) 1/10 Din (S) SS316 (D6) 55 to (=) None (=) None 3) (NH) Tagging wired
(=) Standard
weatherproof 2 wire 6 mm 1000
head Pt500 (3) 1/3rd Din (SA) SS321 mm (02) (F) Fixed Hex (JM) M20X1.5 mm (ST) Spring loaded
female 4)
(S3) Simplex (D8) 1/4” NPT(M) nut terminal
(W) Weather Pt1000 3 wire (A) Class ‘A’ 8 mm (B1) Ni plated
2)
proof -70/300C (04) (NS) Nipple brass double (HT) Head mounted
(S4) Simplex (D10) 1/2” NPT(M) compression transmitter
(B) Ex proof 4 wire (B) Class ‘B’ 10 mm (US) Nipple cable gland7)
enclosure -70/500C (05) union (DE) Double entry for
IIA/IIB certi- (D2) Duplex 3/4” NPT(M) 2) (C1) Ni plated 5)
Nipple head
fied 2 wire (EA) Extend- brass Ex
ed tempera- (13) proof(IIA/IIB)
(D) adjustable (CM) MI cable
(C) Ex proof (D3) Duplex ture Class A 1/4” BSP(M) cable gland 7) 1)
connection extention
enclosure 3 wire -200/600C sliding on (D1) Ni plated brass
IIC certified (15) stem Ex proof(IIC) (CA) Stainless steel
1/2” BSP(M) cable gland7) armored PTFE
(F1) SS double insulated
(17) compression extension
1)6)
3/4” BSP(M) cable gland7) cable
1) Specify length in meter EG. CM1.5 = CM with 1.5m, Max length 20m, only for sheath diameter 6mm
2) Only with connection 1/2” NPT/BSP 3) 3/4” ET for head (E) & 1/2” NPT for others 4) only with weather proof head 5) not for Head type (E)
6) Max temperature limit for extension cable is 250°C 7) For two cable gland, specify the codes as B2, C2… applicable only for (DE)
How to order
Head Type Model Element Element Accuracy Sheath Sheath Sheath Process Connection Electrical Option
type Class Material Diameter Length Connection Type Connection
Features
x High stability sensor
x Mineral insulated for flexibility and durability
x Custom designs for specific applications
Ranges
-200 up to 600 °C
-325 up to 1100 °F
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Pharmaceuticals, Dairy & Food process industry
Pulp and paper industry
Storage Tanks
Power generation
Reactors
Order information
Model Element Element Accuracy Sheath Sheath Sheath Process Connection Extension Cable Option
type class material diameter length connection Type
th
RTW Pt100 (S2) Simplex (1) 1/10 Din (S) SS316 (D4) 4mm 55 to 1000 (=) None (=) None (=) None (NH) Tagging wired
2 wire mm
rd
Pt500 (3) 1/3 Din (SA) SS321 (D6) 6mm (02)1/4” NPT(M) (F) Fixed Hex (CM) MI cable exten-
(S3) Simplex nut sion
Pt1000 3 wire (A) Class ‘A’ (I6) Inconel (D8) 8mm (04)1/2” NPT(M)
-70/300C 600 (D) Adjustable (CA) Stainless steel
(S4) Simplex (D10) 10mm (05)3/4” NPT(M) connection armored PTFE
4 wire (B) Class ‘B’ sliding on insulated exten-
-70/500C (13)1/4” BSP(M) stem sion cable
(D2) Duplex
2 wire (EA) Ex- (15)1/2” BSP(M) (TT) Teflon- Teflon,
tended extension cable
(D3) Duplex temperature (17)3/4” BSP(M)
3 wire Class A (TTS) Teflon- Teflon,
-200/600C (16)M20x1.5(M) SS braided ex-
tension cable
Others on request
1) Specify length of extension cable in meter EG. CM1.5 = CM with 1.5m, Max length 20m, only for sheath diameter 6mm
How to order
Model Element Element Accuracy Sheath Sheath Sheath Process Connection Extension Ca- Option
type Class Material Diameter Length Connection Type ble
Features
x High quality TC cable
x Mineral insulated for flexibility and durability
x General purpose with spring loaded sensor
x Available with weather proof and explosion proof head
x Custom designs for specific applications
Ranges
-200 up to 1200 °C
-325 up to 2200 °F
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Pharmaceuticals, Dairy & Food process industry
Pulp and paper industry
Order information
Head Type Element Element Junction Sheath Sheath Sheath Process Connection Electrical connec- Options
Type material diameter length connection Type tion
(E) Compact (J) Iron - (S) Simplex (G) Grounded (S) SS 316 (D3) 55 to (=) None (=) None 3) (NH) Tagging
1) (=) Standard
weatherproof Constantan 3mm 20000 mm wired
head (D) Duplex (U) Un- (SA) SS (02) (F) Fixed Hex nut (JM) M20X1.5 mm
(K) Chromel grounded 321 (D4.5) 1/4” NPT(M) female (ST) Spring
2)
(W) Weather - Alumel 4.5mm (NS) Nipple (B1) Ni plated loaded
4)
proof (04) brass double terminal
(T) Copper - (D6) 1/2” NPT(M) (US) Nipple union compression
(B) Ex proof Constantan 2)
6mm Nipple cable gland6) (HT) Head
enclosure (05) mounted
IIA/IIB certi- (E) Chromel 3/4” NPT(M) (D) adjustable (C1) Ni plated
(D8) transmitter
fied - Constantan brass Ex
8mm connection
(13) proof(IIA/IIB)
sliding on 6) (DE) Double entry
(C) Ex proof en- (N) Nicrosil - 1/4” BSP(M) cable gland 5)
stem for head
closure IIC Nisil (D1) Ni plated brass
certified (15) Ex proof(IIC)
1/2” BSP(M) cable gland6)
(F1) SS double
(17) compression
3/4” BSP(M) cable gland
6)
1) Element type simplex only and max length 5000mm 2) Only with connection 1/2” NPT/BSP 3) 3/4” ET for head (E) & 1/2” NPT for others 4) Only with weather proof head
5) not for Head type (E) 6) for two cable gland, specify the codes as B2, C2… applicable only for (DE)
How to order
Head Type Model Element Element Junction Sheath Sheath Sheath Process Connection Electrical Option
Type Material Diameter Length Connection Type Connection
E TCH K S G S D6 100 04 D = ST
Ratings
from 620 bar at 20 °C
to 175 bar at 650 °C
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Food and beverage industry
Pulp and paper industry
Technical specification S R H
Solid bore design
Order information
Process U-length Instrument Extension Shank type Bore Material Options
connection in mm connection length
(07) 1¼” NPT(M) (U…) (04T) 1/2” (=) Standard, (S) Straight (6.6) 6.6mm (B) Carbon steel (NH) Tagging stamped
Specify NPT(F) 45mm
(06) 1” NPT(M) length in (R) Stepped (7.0) 7.0mm (C) 304 (1.4301) (CC) Cap & chain
mm2) (15T) 1/2” (EX) Specify stainless steel
(05) 3/4” NPT(M) BSP(F) extension (H) Tapered (8.5) 8.5mm (CL) 304L
E.g. (250) for length in (1.4306) (BP) Buffed and
(04) 1/2” u length (9.8) 9.8mm
250mm mm polished
NPT(M)1) E.g. (E100) for (S) 316 (1.4401)
100mm extension (10.5) 10.5mm3)
(18) 1” BSP(M) length (SL) 316L
(12.5) 12.5mm3) (1.4404) Certification
(17) 3/4” BSP(M) (CDWFC) Wake frequency
(SH) 321 (1.4541) ASME PTC 19.3
(15) 1/2”
BSP(M)1) (ST) 316Ti (CDRH) Rockwell
(1.4571) hardness test
(33) M33 x 2(M)
(M) Monel (X-RAY) X-ray photo
(H) Hastelloy C (CDW9) 100 bar 1 min.
(G) Hastelloy B (CD3) 3.1 Material
certificate MR-01-75
(N) Nickel
(CD5) NACE MR 0175 /ISO
(DU) Duplex 15156-2003 MR-01-75
4)
(IN) Inconel
(CDMA) NACE MR 0175 /ISO
15156-2005 5)
others on request
others on request
1) Max bore diameter 9.8mm and for bore 7.0, 8.5 & 9.8 only shank type (S) straight is available
2) Max length for solid bar stock is 700mm for stainless steel and 600mm for other material, lengths above as fabricated bar stock
3) Not for shank type R (stepped) 4) only for material (H) and (DU) 5) only for material (SL)
How to order
Process Type U-length Instrument Extension Shank type Bore diameter Material Options
Connection connection length
05 TWT 250 04T = H 8.5 SL NH
Features
x Solid bore construction
x Materials according ISO 15156/NACE MR 01-75
x Selection of materials
x Standard and customer specifications
x DIN and ANSI/ASME process connections
Ratings
DIN up to PN100
ANSI/ASME up to 1500 lbs
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Food and beverage industry
Pulp and paper industry
Technical specification S R H
Solid bore design
Shank solid bore, flange welded on shank standard. Optional one piece design, built up design
or to customer specification
Construction shank Straight Stepped Tapered
Order information
Process U- Instrument Extension Type Bore Material Flange Pressu Options
connecti length connection Length facing re
on in mm rating
ANSI (U…) (04T) 1/2” (=) Standard, (H) Standard (6.6) 6.6mm (B) Carbon ANSI ANSI (NH) Tagging stamped
Flanged Specify NPT(F) 57mm with steel Flange Flange
length in Welded (7.0) 7.0mm (CC) Cap & chain
(10) 1” mm2) (15T) 1/2” (EX) Specify Flange (C) 304 (RF) 150 stainless steel
BSP(F) extension Tapered (8.5) 8.5mm (1.4301) Raised 300 (BP) Buffed and polished
(15) 1 ½” E.g. (250) length in Shank face 600
for u length (9.8) 9.8mm (CL) 304L (FL.) Specify flange as
(20) 2” 250mm mm (1.4306) (FF)Flat 900 per material code
(S) Welded 1500
(30) 3” E.g. (E100) for (10.5) 10.5mm1) face 2) (e.g. FLM flange material
Flange (S) 316 Monel)
100mm extension
length Straight (12.5)12.5mm1) (1.4401) (RTJ) Certification
Shank Ring joint
(SL) 316L (CDWFC) Wake frequency
(R) Welded (1.4404) type ASME PTC 19.3
Flange (CDW2) Dye penetration
(SH) 321
Stepped test
(1.4541)
Shank (CDRH) Rockwell
(only bore (ST) 316Ti hardness test
DIN DIN DIN
0,260 (1.4571)
Flanged (6,6mm)) flange flange (BC) Bore
(M) Monel Concentricity
(DN25) the flange PN10 test
(H) Hastelloy facing depends
(DN40) on the process PN16 (X-R1) X-ray for weld
C connection PN25 joint
(DN50) (nominal size PN40
(N) Nickel and nominal (X-R2) X-ray for bore
pressure) PN64
(DN80) PN100 concentricity
(DU) Duplex
(DN100) (CDW9) 100 bar 1 min.
(IN) Inconel
(CD3) 3.1 Material
flange material is certificate
the same as the
shank material (CD5) NACE
other construction unless specified
such as: Solid MR 01-75 /
with code (FL.),
machined, built up see options
ISO 15156-2003 3)
and to customer
others on specification on (CDMA) NACE
request request MR 0175 /
ISO 15156-2005 4)
1) Not for shank type R (stepped) 2) only for size < 3” 3) only for material (H) and (DU) 4) only for material (SL)
How to order
Process Type U-length Instrument Extension Shank type Bore Material Flange Pressure Options
connection connection length diameter facing rating
10 TWF 250 04T = H 9.8 SL RF 150 NH
Triple contacts
EC1110 Contact 1 closes
(NOxNOxNO) Contact 2 closes
Contact 3 closes
240
EC1220 Contact 1 closes
(NOxNCxNC) Contact 2 opens Magnetic spring contact
220
Contact 3 opens Max. Load: 30 W-50 VA-1 A
200
Max. switching voltage: 250 V
EC2110 Contact 1 opens
(NCxNOxNO) Contact 2 closes
180
Contact 3 closes
160
EC1210 Contact 1 closes
Switching voltage in V
Contact type
EC1200 Add contact code to the selected gauge coding
General dimensions in mm
U-type Q-type
Order information
Type Connection Form1) System material Design/schedule Options
SY1 (04)1/2” NPT (M/F) Male X female (C) SS 304 (U40) U type SCH 40 (NH) Tagging Wired
(15)1/2” BSP (M/M)Male X Male (S) SS 316 (Q40) Q type SCH 40 (CDIB) IBR Certified
(16)M20x1.5 (F/F) Female X female (L) SS 316L (Q80) Q type SCH 80 (CD3) Material certificate
(F/B) Female X Blank for weld (CS) Carbon steel for wetted parts
(M/B) Male X Blank for weld ASTM A106
Others on request
1) For Form, First character indicates Process connection and Second character indicates Instrument connection
How to order
Type Connection Form System Design / Options
material schedule
Applications
Process plant, Power plant
Chemical and Petrochemical Industries
Off shore, on shore refineries
Clean air, gas and non-crystallizing media
General dimensions in mm
CT1 CT5
Order information
Type Connection Form1) Options
CT1 (02)1/4” NPT (13)1/4” BSP (M/F) Male X female (NH) Tagging Stamped
CT5 (03)3/8” NPT (14)3/8” BSP (OF) Oil free
(04)1/2” NPT (15)1/2” BSP (CD3) Material certificate for wetted parts
(16)M20x1.5 (CD5) NACE MR 0175/ ISO15156 -2005
Others on request
1) For Form, First character indicates Process connection and Second character indicates Instrument connection
How to order
Type Connection Form Option
Applications
Reciprocating pumps and compressor
Hydraulic Machines and fluid power system
Process plant, Power plant
Chemical and Petrochemical Industries
Off shore and on shore refineries
Clean air, gas and non-crystallizing media
General dimensions in mm
Order information
Type Connection Form1) System Options
material
PD1 (02)1/4” NPT (M/F) Male X female (C) SS 304 (NH) Tagging Stamped
(04)1/2” NPT (S) SS 316 (OF) Oil free
(13)1/4” BSP (L) SS 316L (CD3) Material certificate for
wetted parts
(14)3/8” BSP (P) Monel (10K) Pressure ratting
(15)1/2” BSP 10000PSI
(16)M20x1.5
Others on request
1) For Form, First character indicates Process connection and Second character indicates Instrument connection
How to order
Type Connection Form System Option
material
PD1 04 M/F S CD3
Applications
Machine and apparatus construction
Process plant, Power plant
Chemical and Petrochemical Industries
Off shore, on shore refineries and Mining
General dimensions in mm
Order information
Type Connection Form1) System material Adjustable range Options
(kg/cm2)
PL1 (04)1/2” NPT M/F Male X female (S) 316(1.4401) (A) 1.0 to 2.0 (NH) Tagging Stamped
(15)1/2” BSP (L) 316L (1.4404) (B) 2.0 to 4.0 (OF) Oil free
(16)M20x1.5 (P) Monel (C) 4.0 to 10.0 (CD3) Material certificate for wetted parts
(D) 10.0 to 40.0 (CD5) NACE MR 0175 /ISO 15156 -2005 2)
(E) 40.0 to 160.0
(F) 160.0 to 250.0
Others on request (G) 250.0 to 400.0
1) For Form, First character indicates Process connection and Second character indicates Instrument connection 2) Not for material (S), for material (L) restricted
up to 60oC and for material (P) unrestricted.
How to order
Type Connection Form System Range Options
material
Applications
Isolation of instrument from service
Liquid and vapour service
Process industry, Power plant
Chemical and Petrochemical Industries
Off shore and on shore processes
Oil and gas refineries
General dimensions in mm
Order information
Type Connection Form1) System Options
material
GV1 Gauge isolation valve (04) 1/2” NPT (M/F) Male X female (C) SS 304 (NH) Tagging Stamped
GV2 Two way gauge cock (14) 3/8” BSP (F/F) Female X female (S) SS 316 (OF) Oil free
(CD3) Material certificate
GV3 Three way gauge cock (15) 1/2” BSP (L) SS 316L
for wetted parts
Others on request
1) For Form, First character indicates Process connection and Second character indicates Instrument connection
How to order
Type Connection Form System Options
material
Applications
Isolation of instrument from service
High pressure lines
Liquid and vapour service
Process industry, Power plant
Chemical and Petrochemical Industries
Off shore and on shore processes
Oil and gas refineries
Order information
Type Connection Form1) System material Options
NV1 (02) 1/4” NPT (M/F) Male X female (S) 316(1.4401) (NH) Tagging Stamped
(03) 3/8” NPT (F/F) Female X female (L) 316L (1.4404) (VP) Vent Plug
(OF) Oil free
(04) 1/2” NPT (M/M) Male X Male (P) Monel
(CD3) Material certificate for
(13) 1/4” BSP (H) Hastelloy-C276 wetted parts
(14) 3/8” BSP (CD5) NACE MR 0175/
(15) 1/2” BSP ISO15156 -2005
(16) M20x1.5
Others on request
1) For Form, First character indicates Process connection and Second character indicates Instrument connection
How to order
Type Connection Form System Options
material
Features
x Stainless steel construction Optional Monel & Hastelloy-C276
x Isolates and bleeds process from Measuring Instrument assembly
x Provision of dust caps that prevent dust Ingress
x Supplied with wetted parts according to NACE MR0175
x The controlled vent provides the option of draining
to process fluid to colletor or atmospher
x PTFE packing optional grafoil
Applications RM-type
Chemical & petrochemical industries& refineries
Off shore and on shore fields
Storage tanks of fluids/gas
Thermal & nuclear power generation units
Waste treatment plant
OEM & machine apparatus
Seawater desalination plants
R-type
Order information
Type Mounting Connection Form System material Options
Inlet X Outlet
2VM (RM) Remote mount (02) 1/4” NPT (M/F) Male X female1) (S) 316(1.4401) (NH) Tagging Stamped
(R) Pipe to pipe (04) 1/2” NPT (F/F) Female X female (OF) Oil free
(L) 316L (1.4404)
(03) 3/8” NPT (CD3) Material certificate
(13) 1/4” BSP (P) Monel for wetted parts
(T) Pipe to flange (14) 3/8” BSP (F/FL) Female X flange (10K) Pressure ratting
(H) Hasteloy-C276 10000PSI2)
(15) 1/2” BSP
(G) Grafoil packing
(H) Flange to flange (=) Flange (FL/FL) Flange X flange (CD5) NACE MR 0175/
Others on request ISO15156 -2005
1) Only for (RM) type 2) Detailed drawing shall be provided on request
How to order
Type Mounting Connection Form System Options
material
RM-type
R-type
T-type
H-type
Applications
Chemical & petrochemical industries, refineries
Off shore and on shore fields
Storage tanks of fluids/gas
Thermal & nuclear power generation units
Waste treatment plant
OEM & machine apparatus
Seawater desalination plants
Chemical injecttion skids
Order information
Type Mounting Connection Form System material Options
Inlet X Outlet
3VM (R) Pipe to pipe (02) 1/4” NPT (F/F) Female X female (S) 316(1.4401) (NH) Tagging Stamped
(04) 1/2” NPT (OF) Oil free
(L) 316L (1.4404)
(03) 3/8” NPT (CD3) Material certificate
(13) 1/4” BSP (P) Monel for wetted parts
(T) Pipe to flange (F/FL) Female X flange (10K) Pressure ratting
(14) 3/8” BSP (H) Hasteloy-C276 10000PSI1)
(15) 1/2” BSP
(G) Grafoil packing
(H) Flange to flange (=) Flange (FL/FL) Flange X flange (CD5) NACE MR 0175/
Others on request ISO15156 -2005
1) Detailed drawing shall be provided on request
How to order
Type Mounting Connection Form System Options
material
R-Type
T-type
H-type
Applications
Chemical & petrochemical industries, refineries
Off shore and on shore fields
Storage tanks of fluids/gas
Thermal & nuclear power generation units
Waste treatment plant
OEM & machine apparatus
Seawater desalination plants
Chemical injecttion skids
Order information
Type Mounting Connection Form System material Options
Inlet X Outlet
5VM (R) Pipe to pipe (02) 1/4” NPT (F/F) Female X female (S) 316(1.4401) (NH) Tagging Stamped
(04) 1/2” NPT (OF) Oil free
(L) 316L (1.4404)
(03) 3/8” NPT (CD3) Material certificate
(13) 1/4” BSP (P) Monel for wetted parts
(T) Pipe to flange (14) 3/8” BSP (F/FL) Female X flange (10K) Pressure ratting
(H) Hasteloy-C246 10000PSI2)
(15) 1/2” BSP
(G) Grafoil packing
(H) Flange to flange (=) Flange (FL/FL) Flange X flange (CD5) NACE MR 0175/
Others on request ISO15156 -2005
1) Detailed drawing shall be provided on request
How to order
Type Mounting Process Form System Options
Connection material
R-type
T-type
H-type