0% found this document useful (0 votes)
26 views2 pages

RedSky Lighting - Catalog

This document provides information about hazardous location lighting basics for an alcohol processing area in Plainfield, Illinois. It defines Class I, II, and III hazardous locations and their divisions according to the National Electric Code. It also summarizes IEC zone classifications, IP codes, IK ratings, and temperature codes that are relevant for lighting in hazardous areas where flammable gases, combustible dusts, or fibers may be present.

Uploaded by

Mr. Junior
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views2 pages

RedSky Lighting - Catalog

This document provides information about hazardous location lighting basics for an alcohol processing area in Plainfield, Illinois. It defines Class I, II, and III hazardous locations and their divisions according to the National Electric Code. It also summarizes IEC zone classifications, IP codes, IK ratings, and temperature codes that are relevant for lighting in hazardous areas where flammable gases, combustible dusts, or fibers may be present.

Uploaded by

Mr. Junior
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Alcohol Processing Area in Plainfield, Illinois

Alcohol Processing Area in Plainfield, Illinois

HAZARDOUS LOCATION LIGHTING BASICS


CLASSES DIVISIONS GROUPS
Class I: Gases Division 1: Always Present Class I: Gases
Areas in which flammable gases or vapors in the air in Areas in which ignitable concentrations of hazards exist Group A - Acetylene
sufficient quantities to ignite or explode. under normal operation conditions and/or where hazard is Group B - Hydrogen
Class II: Dust caused by frequent maintenance or repair work or frequent
Group C - Ethylene
equipment failure.
Areas in which combustible dust may be suspended in the Group D - Propane
air or accumulates on electrical equipment in quantities
Division 2: Not Normally Present Class II: Dusts
sufficient to ignite or explode.
Areas in which ignitable concentrations of hazards are Group E - Electrically conductive dust
Class III: Fibers
normally in closed containers or closed systems. Hazards Group F - Carbonaceous dust
Areas in which easily ignitable fibers or flyings are present. may be present due to accidental rupture or breakdown of
Typically fibers and flyings are not suspended in the air, but Group G - Agricultural and polymer dust
such containers or systems.
can collect around machinery or on lighting fixtures. For complete Information, refer to the National Electric Code (NEC)

IEC ZONE CLASSIFICATIONS COMPARISON UL STANDARDS


IEC publication 60079-10 uses Zones to define the guidelines for Hazardous NEC U.S. IEC
Material Standards Standards
Number Certified Usage
classifying hazardous areas.
Zone 0 - Areas where explosive gas atmosphere is continuously present or Class I, 844 Lighting fixtures for use in
present for long periods of time. Division 1 Zone 0, 1 hazardous classified areas
Gas or
Zone 1 -Areas where explosive gas atmosphere is likely to occur in Vapor
Class I,
normaloperation or can be expected to be present frequently.
Division 2 Zone 2 924 Emergency lighting and power
equipment
Zone 2 - Areas where explosive gas atmosphere is not likely to occur and if
it does, it will only be present for a short period of time. Class II,
Division 1 Zone 20
Zone 20 - Areas in which a combustible dust, as a cloud, is present 1598 Lighting fixtures approved for
Dust wet locations
continuously or frequently during normal operations in sufficient quantities Class II,
Division 2 Zone 22
to produce an explosive mixture.
1598A Lighting approved for use on
Zone 21 - Areas in which a combustible dust, as a cloud, is likely to occur Class III, marine vessels. Salt water
during normal operations in sufficient quantities to produce an explosive Division 1 No Equivalent corrosive rated.
mixture. Fibers
Zone 22 - Areas in which combustible dust, as a cloud, is not likely to occur, or Flyings Class III,
No Equivalent 8750 LED safety
but may occur infrequently and persist for only short periods of time. Division 2

IP CODES IK RATINGS T-CODES


1st Number: Solid Objects 2nd Number: Liquids IK Code Level of Protection Achieved Maximum Operating Temperature
Temperatures Class
0 No protection 0 No protection IK00 Not protected
°C °Fi (T-Code)
1 Objects greater than 50mm 1 Vertically dripping IK01 Protected against 0.14 joules impact
450 842 T1
2 Objects greater than 12.5mm 2 Dripping up to 15° IK02 Protected against 0.2 joules impact 300 572 T2
IK03 Protected against 0.35 joules impact 280 536 T2A
3 Objects greater than 2.5mm 3 Limited spraying
260 500 T2B
Splashing from all directions IK04 Protected against 0.5 joules impact 230 446 T2C
4 Objects greater than 1mm 4
IK05 Protected against 0.7 joules impact 215 419 T2D
5 Dust protected 5 Hosing jets from all directions 200 392 T3
IK06 Protected against 1 joules impact 180 356 T3A
6 Dust proof 6 Strong hosing jets from all directions

7 Temporary immersion
IK07

IK08
Protected against 2 joules impact

Protected against 5 joules impact


165
160
135
329
320
275
T3B
T3C
T4
CONTACT US
8 Continuous immersion 120 248 T4A

9K Steam-jet cleaning
IK09 Protected against 10 joules impact
100 212 T5 1 (262) 456-5002
IK10 Protected against 20 joules impact 85 185 T6
contact@redskylighting.com
RED SKY LIGHTING LLC 1 (262) 456-5002 www.redskylighting.com
9370 Pittsburgh Ave contact@redskylighting.com
Rancho Cucamonga, CA 91730, USA www.redskylighting.com
HARSH & HAZARDOUS (UL) HARSH & HAZARDOUS (UL) HARSH & HAZARDOUS (ATEX & IECEX) HIGH TEMPERATURE
BLOCK-MINI SERIES H1 BLOCK-MINI SERIES H2 BLOCK SERIES X1 HIGH BAY HOT SERIES
For low wattage explosion proof applications For a lower wattage, compact hazardous location light For harsh, extreme heat environments
ATEX Standard
Class l Division 1, Class l Division 2 Class l Division 2, Class ll Division 1 Operating Temperature:
Ex II 2G Ex db IIB T5 Gb
Class ll Division 1, Class lll Class lll, IP66 -40°F to + 176°F (-40°C to + 80°C)
Ex II 2D Ex tb IIIC (T95C° Max) Db IP 66
IP66, IP67 IP67
EN IEC 60079-0, EN 60079-1, EN 60079-31
Zone 1,21 / Zone 2,22
IP67 IP67

Wattage: 21W 40W 50W 60W Wattage: 150W 300W


Wattage: 21W 40W 50W 60W
Lumens (Lm): 4200/6500/7180/8515 Lumens (Lm): 19,600 (110°), 17,223 (60°)
Lumens (Lm): 4220/6500/7180/8515
Warranty: LEDs: 10 Years, Driver: 7 Years Warranty: Standard: 3 Years; Extended: 5 Years
Warranty: LEDs: 10 Years, Driver: 7 Years

BLOCK SERIES H1 BLOCK SERIES H2 MODULAR HOT SERIES


For explosion proof environments For harsh and hazardous environments For indoor high/low bay and outdoor flood lighting for high
Class l Division 1, Class l Division 2 Class I Division 2, Class II Division 2, temperature locations
Class ll Division 2, Class lll Class III, IP66 Oprating Temperature:
IP66 Wattage: 20W 40W 60W 80W 100W 120W 150W -40°F to + 158°F (-40°C to + 70°C) - TG
Lumens (Lm): 2400/4400/6000/9600/12000/16000/19500 -40°F to + 149°F (-40°C to + 65°C) - PC
Warranty: 5 Years

Wattage: 80W 100W 150W


Wattage: 80W, 100W, 150W Lumens (Lm): 10400/13000/19500
Lumens (Lm): 10400/13000/19500 Warranty: LEDs: 10 Years, Driver: 7 Years LINEAR LOW PROFILE SERIES
Warranty: LEDs: 10 Years, Driver: 7 Years
IECEX: Wattage: 200W 400W 600W 800W
ROUND SERIES Ex db eb mb IIC T6 Gb(20 to 60W) Lumens (Lm): 30500/57500/87500/114500
LINEAR TUFF SERIES (Battery option available) Ex db eb mb IIC T5 Gb(>60 to 100W)
Warranty: 5 Years
For corrosive & hazardous locations
For explosion proof environments with low ceiling applications Ex tb IIIC T80°C Db
Class l Division 2, Class ll Division 1
Class l Division 1, Class l Division 2 Class ll Division 2, Class lll INDUSTRIAL
IP66 IP66 ATEX:
II 2 G Ex db eb mb IIC T6 Gb(20 to 60W)
TUFF TUBE SERIES
II 2 G Ex db eb mb IIC T5 Gb(>60 to 100W)
II 2 D Ex tb IIIC T80°C Db For harsh conditions in polluted environments where a high
Wattage: 40W 80W Wattage: 40W 45W 60W* 65W level of quality lighting is needed. Handles water, dust, humidity,
Lumens (Lm): 4425/9160 Lumens (Lm): 6,150/6,750/10,050/10150 Zone 1,21 corrosion, vibration, and sudden impact with ease
Warranty: LEDs: 10 Years, Driver: 7 Years Warranty: LEDs: 10 Years, Driver: 7 Years

LINEAR SERIES (Battery option available) ROUND-MAX SERIES


For hazardous environments with low ceiling applications For indoor high/mid bay & outdoor Wattage: 20W 36W 45W
Class l Division 2, Class ll Division 1 Lumens (Lm): 2700/4860/6075
Class l Division 2, Class ll Division 1
Warranty: 5 Years
Class lll, IP66 Class ll Division 2, Class lll, IP66

DLC SCAN TO LEARN MORE


Contact us:
1 (262) 456-5002
Wattage: 40W 80W Wattage: 80W 120W 150W 200W Wattage: 20W 40W 60W 80W 100W contact@redskylighting.com
Lumens (Lm): 5533/11548 Lumens (Lm): 12000/18000/22500/30000 Lumens (Lm): 2400/4400/6800/8700/10000 www.redskylighting.com
Warranty: LEDs: 10 Years, Driver: 7 Years Warranty: LEDs: 10 Years, Driver: 7 Years Warranty: Fixture: 5 Years. Battery: 1 Year

You might also like