Catalog 1006
Catalog 1006
Content
Wall mount SYS1052-W2E series 3W~6W
GREEN MODE RoHS
Dimension : 52 × 37 × 62 [mm]
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Basic Models
[4.0V~24V] [A] [W] [mV] p-p [mm]
SYS1052-0605-W2E 5 0~1.2 6 200 2.1x5.5x11
OUTPUT CE
Turn delay 5000ms max@AC low line input@output full load EMC 2014/30/EU
2014/35/EU
Hold up time 8ms min@AC nominal input@output full load LVD
EN60950-1 : 2006 + A11 + A1 + A12 + A2
Efficiency (Normal) Meet DOE level VI SAFETY
Burn in limit 220VAC 80% Load (Ref) 4 hours & 40°C + 5°C -0°C cUL | FCC | GS | CE | CB | RCM | PSE | CCC | T-license
Frequency (47~63)hz Cable Length 1370mm (4.5 feet) standard cable or as required
Current 0.2A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature 25°C Housing material PC
PROTECTION ENVIRONMENT
Temperature Operating: 0~40℃ / Storage: -20~85℃
The power supply will be auto recovered when over current or
Over current/
short circuit faults remove (fold back). Is defined as any output
Short protection Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
impedance of less than 0.1Ω.The power supply will be auto
WEIGHT
Over Voltage The power supply will not be auto recovered when faults remove
NW: 56g/pc
Input protection F1:1A 250V Fuse The power supply shall be protected against
GW: 73g/pc
No Load protection The power supply is provided with no load operation to prevent PACKING
Protection class II Box 100 pcs/1 box
www.sunny-euro.com
Wall mount SYS1052-W2E series 3W~6W
Mechanical specification:
Cable specification:
www.sunny-euro.com
Wall mount SYS1001-Wxx series 5W~6W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1001-0505-Wxx* 5 0~1.0 5 150 2.1x5.5x11
SYS1001-0608-Wxx* 7,5 0~0.8 6 150 2.1x5.5x11
SYS1001-0609-Wxx* 9 0~0.66 6 150 2.1x5.5x11
SYS1001-0612-Wxx* 12 0~0.5 6 150 2.1x5.5x11
SYS1001-0615-Wxx* 15 0~0.4 6 200 2.1x5.5x11
SYS1001-0618-Wxx* 18 0~0.33 6 200 2.1x5.5x11
SYS1001-0624-Wxx* 24 0~0.25 6 240 2.1x5.5x11
Features:
Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | W2C - China | W2K - Korea
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
OUTPUT CE
Turn delay 3000ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load 2014/35/EU
LVD
Efficiency (Normal) >72%@115v/60HZ,230V/50HZ input &Full load EN60950-1 : 2006 + A11 + A1 + A12 + A2
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
www.sunny-euro.com
Wall mount SYS1001-Wxx series 5W~6W
Cable specification:
www.sunny-euro.com
Wall mount SYS1121-Wxx series 6W
GREEN MODE RoHS
Dimension : 68 × 42 × 29 [mm]
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Basic Models
[4.0V~24V] [A] [W] [mV] p-p [mm]
SYS1121-0605-Wxx 5 0~1.2 6 200 2.1x5.5x11
OUTPUT CE
Turn delay 3000ms max@AC low line input@output full load EMC 2014/30/EU
2014/35/EU
Hold up time 8ms min@AC nominal input@output full load LVD
EN60950-1 : 2006 + A11 + A1 + A12 + A2
Efficiency (Normal) Meet DOE level VI SAFETY
Burn in limit 220VAC 80% Load (Ref) 4 hours & 40°C + 5°C -0°C cUL | FCC | GS | CE | CB | RCM | PSE | CCC | T-license
Frequency (47~63)hz Cable Length 1370mm (4.5 feet) standard cable or as required
Current 0.5A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature 25°C Housing material PC
(cold start) @115Vac/230Vac nominal AC input
Temperature coefficient: < ±0.5% / °C
leakage current < 5 mA max
ENVIRONMENT
PROTECTION
Temperature Operating: 0~40℃ / Storage: -20~85℃
The power supply will be auto recovered when over current or
Over current/
short circuit faults remove (fold back). Is defined as any output Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
Short protection
impedance of less than 0.1Ω.The power supply will be auto
WEIGHT
The power supply will not be auto recovered when faults remove
Over Voltage
110%-150%. (Voltage limit) NW: 69 g/pc (without plugs) + W2E plug 24g; W3U plug 19g; W2 plug 13g; W2A plug 13g
F1:1A 250V Fuse The power supply shall be protected against
Input protection
power line surges and any abnormal condition GW: 89 g/pc (without plugs)
The power supply is provided with no load operation to prevent
No Load protection PACKING
the power supply and system from damage.
www.sunny-euro.com
Wall mount SYS1121-Wxx series 6W
Mechanical specification:
W2E - Europe
W3U - England
W2A - Australia
Cable specification:
www.sunny-euro.com
Wall mount SYS1421-Wxx series 2.5W~6W
GREEN MODE RoHS
Approvals / Marks :
Features:
Overload, over voltage & short protection. PSU housing ready for use in country :
Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz. USA/Japan/ (type W2) Europe (type W2E)
Wall-mount power supply, single output. Australia (type W2A) Korea (type W2K)
For I.T.E. use only + RoHS conform. UK (type W3U) China (type W2C)
Specification:
Voltage Max. Ripple Connector
Loading Tol. OCP OVP Efficiency
Model DC Power & Noise UL approval
[A] [%] [A] [V] [%]
[V] [W] [mV] p-p [mm]
SYS1421-0605-Wxx 5 0~1.2 ±5 1.5~3.5 12±4 >69.53 6 150 2.1x5.5x11
SYS1421-0605-Wxx 5 0~1.2 ±5 1.3~3.0 12±4 >68.10 6 150 mini USB
SYS1421-0605-Wxx 5 0~1.2 ±5 1.3~3.0 12±4 >66.49 6 150 micro USB
ErP V.
SYS1421-0605-Wxx 5 0~1.2 ±5 0.75~2 12±4 >62.97 6 150 USB inlet
SYS1421-0612-Wxx 12 0~0.5 ±5 0.6~2.0 17±4 >73.41 6 150 2.1x5.5x11
ErP V. / CE only SYS1421-0303-Wxx 3.3 0~1.0 ±5 1.2~2.5 8 >62.00 3.3 150 2.1x5.5x11
Wxx Possible to order with Wxx = W2E - Europe | W2 - USA,Canada,Japan | W3U - UK | W2A - Australia | W2C - China | W2K -Korea
OEM Production This model is certified for Uout= 5V & Pout=(2.5 or 4 or 5 or 6)W and Uout=12V/Pout=6W
Turn on delay 3000 ms max @ AC low line input@output full load
Hold up time 8ms min @ AC nominal input@ output full load (> half cycle)
Efficiency (Normal) In the table above minimum average efficiency in active mode (Meet EuP2)
OUTPUT 0.4V dv max @ AC nominal input loading from 20% load to 80% load
Transient response (dv, tmax)
6ms tmax | Dynamic rise time 10uS max, duty 40mS max, Dynamic load step is slew rate of 0.5A/uS
Power out. Limit Peak 7W for model- 0605
Burn in test Full load 2 Hours before testing
Voltage (90 ~ 264)VAC
Frequency (47 ~ 63) Hz
Current 0.5A rms @ AC low line input and DC output full load
INPUT
Inrush Surge Current (cold start) 30/60A max @ power supply cold start, ambient temperature 25℃@115Vac / 230Vac nominal AC input.
Leakage current 0.25 mA Max.
Power consumption 0.3W rms max. At AC nominal input @ output min load
The power supply will self-protect any output to ground, and auto recovery when abnormal circuit faults remove.
Over Current /Short protection
An output short circuit is defined as any output impedance of less than 0.1 ohms. [OCP]
Over Voltage The power supply will not be auto recovered when faults remove >>Voltage limit<< [OVP]
PROTECTION Input protection 1A Fuse or 10R2W| The power supply shall be protected against power line surges and any abnormal condition.
No load protection The power supply is provided with no load operation to prevent the power supply and system from damage.
Protection class II.
Dielectric Strength (Hi-pot) Primary to Secondary: 3000VAC / 10mA / 60s
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Standard 2468#24/5ft | for USB products round cable 1185#22/6ft | for SYS1421-0303 2468#22/4,5ft or depends on customer
Cable length / type
OTHERS requirements.
PLD (power line disturbance ) LINE POWER SURGE | LINE VOLTAGE SAG – more information will be provide on request
Cooling method By natural air
Temperature coefficient: < ±0.5% / °C
Temperature Operating: (0 ~ 40)°C / Storage: (-20 ~ 85)°C
ENVIRONMENT
Humidity Operating: 8% ~ 90% RH / Storage: 5% ~ 95% RH non condensing
SAFETY CE | TUV/GS | CB | cULus | FCC | BSMI | PSE | VCCI | C-TICK | T-licence | KC | RCM
EMC 2014/30/EU
CE 2014/35/EU
LVD
EN60950-1 : 2006 + A11 + A1 + A12 + A2
WEIGHT 1pc N.W.: 79g | G.W.: 95g
0.435(L) x 0.370(W) x 0.175(H) [m]
PACKING Box 100 pcs / 1box
G.W.: 10.5kg/box
www.sunny-euro.com
Wall mount SYS1421-Wxx series 2.5W~6W
US / Japan type (W2) UK type (W3U) Europe type (W2E) China type (W2C) Australia type (W2A) Korea (type W2K)
Cable specification:
www.sunny-euro.com
Wall mount SYS1573-Wxx series 6W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1573-0605-Wxx 5 0~1.2 6 150 2.1x5.5x11
SYS1573-0605-Wxx 5 0~1.2 6 150 mini USB
SYS1573-0605-Wxx 5 0~1.2 6 150 micro USB
SYS1573-0605-Wxx 5 0~1.2 6 150 USB inlet
SYS1573-0612-Wxx 12 0~0.5 6 200 2.1x5.5x11
Features:
PSU housing ready for use in country : Wxx = W2E - Europe | W3U - England | W2 - USA, Canada | W2C - China | W2K - Korea | W2J - Japan
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max @ AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle) 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
Meet CEC,DOE,ERP,MEPS Level VI
Efficiency (Normal)
@115v/60HZ,230V/50HZ SAFETY
0.4v dv max At AC nominal input loading from 50% load to
Transient response max load or peak load UL | FCC | CB | PSE
(dv,tmax) 6ms tmax | Dynamic rise time 10uS max , duty 40mS max ,
Dynamic load step is slew rate of 0.5A/uS OTHERS
Power out.Limit Peak 7W for model 0605 Dielectric Strength
Primary to Secondary:3000VAC 10mA/60S
(Hi-pot)
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Less than 0.075W ms max. At AC nominal input@output min
Power consumption
load Cable Length 1830mm (6 feet) standard 2 wire cable or as required
INPUT PLD
Line power surge | Line voltage SAG-more info on request
(power line disturbance)
Voltage (90~264)VAC
Cooling method Natural Convection Cooling
Frequency (47~63)hz
Housing material PC or PPO
Current 0.5A rms @ AC low line input and DC output full load
Inrush Surge Current 30/60A max@power supply cold start,ambient temperature Temperature coefficient: < ±0.5% / °C
(cold start) 25°C @115Vac/230Vac nominal AC input
The power supply will self-protect any output to ground & auto Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
Over current/ recovery when abnormal circuit faults remove. An output short
Short protection circuit is defined as any output impedance less than 0.1
WEIGHT
ohms.
Over Voltage The power supply will be auto recovered when faults remove NW: 50g/pc
www.sunny-euro.com
Wall mount SYS1573-Wxx series 6W
US / Canada type (W2) UK type (W3U) Europe type (W2E) China type (W2C) Japan type (W2J) Korea (type W2K)
Cable specification:
www.sunny-euro.com
Wall mount SYS1561-Wxx series 10.5W~12W
GREEN MODE RoHS
Dimension : 65 x 45 x 30 [mm]
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1561-1105-Wxx* 5 0~2.1 10.5 200 2.1x5.5x11
SYS1561-1105-Wxx* 5 0~2.1 10.5 200 micro USB
SYS1561-1105-Wxx* 5 0~2.1 10.5 200 5C USB-C
SYS1561-1105-Wxx* 5 0~2.1 10.5 200 USB inlet
SYS1561-11054-Wxx* 5.35 0~2.0 10.7 200 2.1x5.5x11
SYS1561-1006-Wxx* 6 0~1.66 10 200 2.1x5.5x11
SYS1561-1212-Wxx* 12 0~1.0 12 200 2.1x5.5x11
Features:
Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan, Taiwan | W2A - Australia | W2C - China
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max @ AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle) 2014/35/EU
LVD
Meet CEC,DOE,ERP,MEPS Level VI EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal)
@115v/60HZ,230V/50HZ SAFETY
0.3v dv max At AC nominal input loading from 50% load to
Transient response max load or peak load UL | GS | CB | CE | FCC |BSMI | PSE | SAA | RCM | EAC
(dv,tmax) 8ms tmax | Dynamic rise time 10uS max , duty 40mS max ,
Dynamic load step is slew rate of 0.5A/uS
OTHERS
Dielectric Strength
Power out.Limit Peak 13W for SYS1561-1212 Primary to Secondary:3000VAC 10mA/60S
(Hi-pot)
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Less than 0.075W ms max. At AC nominal input@output min
Power consumption
load Cable Length 1370mm (4.5 feet) standard cable or as required
INPUT PLD
Line power surge | Line voltage SAG-more info on request
(power line disturbance)
Voltage (90~264)VAC
Cooling method Natural Convection Cooling
Frequency (47~63)hz
Housing material PC
Current 0.5A rms @ AC low line input and DC output full load
Temperature coefficient: < ±0.5% / °C
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature
No Load protection
The power supply is provided with no load operation to PACKING
prevent the power supply and system from damage.
80 pcs /1 box
Protection class II, (ITU-T K.21 Surge 6KV on request) PE plastic bag
180 pcs / 1box (for USB inlet)
www.sunny-euro.com
Wall mount SYS1561-Wxx series 10.5W~12W
Cable specification:
www.sunny-euro.com
Wall mount SYS1001-Wxx series 7.26W~12W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1001-0703-Wxx* 3,3 0~2.2 7.26 120 2.1x5.5x11
SYS1001-1105-Wxx* 5 0~2.1 10 120 2.1x5.5x11
SYS1001-1108-Wxx* 7.5 0~1.6 11 120 2.1x5.5x11
SYS1001-0909-Wxx* 9 0~1.33 9 120 2.1x5.5x11
SYS1001-1212-Wxx* 12 0~1.0 12 200 2.1x5.5x11
SYS1001-1215-Wxx* 15 0~0.8 12 200 2.1x5.5x11
SYS1001-1218-Wxx* 18 0~0.66 12 240 2.1x5.5x11
SYS1001-1224-Wxx* 24 0~0.5 12 240 2.1x5.5x11
Features:
Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | W2C - China | W2K - Korea
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal) >80%@115v/60HZ,230V/50HZ input &Full load
0.4V dv max At AC nominal input loading from 20%load to 80% SAFETY
Transient response load
cUL | FCC | GS | CE | CB | RCM | EAC | BSMI | PSE | CCC | VCCI
(dv,tmax)
16ms tmax Dynamic rise time 10 us max,duty 40ms
OTHERS
Power out.Limit 12W Dielectric Strength
I/P-O/P:3000VAC
(Hi-pot)
Burn in limit Full load 2 Hours
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Voltage (90~264)VAC
PLD Line power surge | Line voltage SAG-more info on request
Frequency (47~63)hz
Cooling method Natural Convection Cooling
Current 0.5A rms@AC low line input and DC output full load
Housing material PC + ABS
Inrush Surge Current 30/40A max@power supply cold start,ambient temperature 25°C
Temperature coefficient: < ±0.5% / °C
leakage current 0.25mA Max
ENVIRONMENT
PROTECTION
Temperature Operating: 0~40℃ / Storage: -20~85℃
The power supply will be auto recovered when over current or
Over current/
short circuit faults remove (fold back). Is defined as any output Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
Short protection
impedance of less than 0.1Ω.The power supply will be auto
WEIGHT
The power supply will not be auto recovered when faults remove
Over Voltage
110%-150%. (Voltage limit) NW: 80g/pc + plug
F1 1A/250V Fuse The power supply shall be protected against
Input protection GW:95g/pc + plug
power line surges and any abnormal condition
The power supply is provided with no load operation to prevent
No Load protection PACKING
the power supply and system from damage.
Protection class II Box 100 pcs/1 box
www.sunny-euro.com
Wall mount SYS1001-Wxx series 7.26W~12W
Cable specification:
www.sunny-euro.com
Wall mount SYS1121-Wxx series 12W
GREEN MODE RoHS
Dimension : 68 × 42 × 29 [mm]
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Basic Models
[4.0V~24V] [A] [W] [mV] p-p [mm]
SYS1121-1105-Wxx 5 0~2.2 11 200 2.1x5.5x11
OUTPUT CE
Turn delay 3000ms max@AC low line input@output full load EMC 2014/30/EU
2014/35/EU
Hold up time 8ms min@AC nominal input@output full load LVD
EN60950-1 : 2006 + A11 + A1 + A12 + A2
Frequency (47~63)hz Cable Length 1370mm (4.5 feet) standard cable or as required
Current 0.5A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling
Housing material PC
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature 25°C
www.sunny-euro.com
Wall mount SYS1121-Wxx series 12W
Mechanical specification:
W2E - Europe
W3U - England
W2A - Australia
Cable specification:
www.sunny-euro.com
Wall mount SYS1460-Wxx series 10.5W~12W
GREEN MODE RoHS
Dimension : 65 x 45 x 30 [mm]
Approvals / Marks :
Features:
Also available in version of K.21 Protection against interference. For Telecom Products / Enclosure / STB. PSU housing ready for use in country :
Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz. USA/Japan/ (type W2) Europe (type W2E)
Wall-mount power supply, single output. Australia (type W2A) UK (type W3U)
For I.T.E. use only + RoHS conform. Overload, over voltage & short protection. China (type W2C)
Specification:
Voltage Max. Ripple Connector
Loading Tol. OCP OVP Efficiency
Model DC Power & Noise UL approval
[A] [%] [A] [V] [%]
[V] [W] [mV] p-p [mm]
SYS1460-1105-Wxx 5 0~2.1 ±5 2.2~4 10±4 ≥73.88 10.5 100 2.1x5.5x11
ErP V.
Wxx Possible to order with Wxx = W2E - Europe | W2 - USA,Canada,Japan | W3U - UK | W2A - Australia | W2C - China
OEM Production This model is certified for Output : (5, 5.1, 5.2)V & (1~10)W by 1W steps for each Uout and 12V/(1~12)W by 1W steps.
Turn on delay 3000 ms max @ AC low line input@output full load
Hold up time 6ms min @ AC nominal input @ output full load (> half cycle)
Efficiency (Normal) Above minimum average efficiency in active mode( Meet CEC V)
OUTPUT 0.3v dv max At AC nominal input loading from 50% load to max load or peak load
Transient response (dv, tmax)
8ms tmax | Dynamic rise time 10uS max , duty 40mS max , Dynamic load step is slew rate of 0.5A/uS
Burn in test Full load 2 Hours
USB inlet model FOR USB inlet model: +5V(PIN1) | (0~2)A ±5% (PIN2&PIN3short) | 0V (PIN4)
Voltage (90 ~ 264)VAC
Frequency (47 ~ 63) Hz
Current 0.5A rms @ AC low line input and DC output full load
Inrush Surge Current (cold start) 40/60A max @ power supply cold start, ambient temperature 25℃@115Vac / 230Vac nominal AC input.
INPUT
Leakage current 0.25 mA Max.
Power consumption 0.3W rms max. At AC nominal input@output min load
Hold up time 6ms
Wattage Input wattage is below 15W on the condition that AC 100V/50HZ and full load
The power supply will self-protect any output to ground, And auto recovery when abnormal circuit faults remove.
Over Current /Short protection An output short circuit is defined as any output impedance of less than 0.1 ohms.
Protection against interference. ITU-T K.21 (option) – depends on customer request
Over Voltage The power supply will not be auto recovered when faults remove >>Voltage limit<<
PROTECTION
Input protection 1A/250V | The power supply shall be protected against power line surges and any abnormal condition.
No load protection The power supply is provided with no load operation to prevent the power supply and system from damage.
Protection class II.
Dielectric Strength (Hi-pot) Primary to Secondary: 3000VAC / 10mA / 60s
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Cable length / type 2468#24(or 20)*2C, 4.5FT 2wires cable or depends on customer requirements
OTHERS PLD (power line disturbance ) LINE POWER SURGE | LINE VOLTAGE SAG – more information will be provide on request
Cooling method By natural air
Housing material -
Temperature coefficient: < ±0.5% / °C
Temperature Operating: (0 ~ 40)°C / Storage: (-20 ~ 85)°C
ENVIRONMENT
Humidity Operating: 8% ~ 90% RH / Storage: 5% ~ 95% RH non condensing
SAFETY CE | CB |TUV/GS | cULus | FCC | BSMI | PSE | C-tick | CCC | EAC | RCM | T-license
EN 55022 (2006)+ A1:2007 Class B
EMI
EN 61000-3-2 (2006) + A1(2009) + A2 Class A(2009)/EN 61000-3-3 (2008)
EMC EN55024(1998)+A1(2001)+A2(2003) | IEC 61000-4-3 | IEC 61000-4-4 | IEC 61000-4-5 | UL 60950-1,2nd Edition CSA C22.2
EMS
No.60950-1-07
WEIGHT 1pc N.W.: 47-130g(±10g) / pc | G.W.: -g / pc
485(L)*460(W)*358(H) [mm]
PACKING Box
96-210 pcs /1box G.W.: various kg/box
www.sunny-euro.com
Wall mount SYS1460-Wxx series 10.5W~12W
Cable specification:
www.sunny-euro.com
Wall mount SYS1381-Wxx series 6W~12W
GREEN MODE RoHS
Approvals / Marks :
Features:
Available in version: W2E(EU), W2(USA/Japan/Canada/Taiwan), W3U(UK), W2A (Australia), W2C (China), W2K(Korea).
Wall-mount power supply, single output. Overload, over voltage & short protection.
Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz. For I.T.E. use only + RoHS conform.
Specification:
Voltage Total Hold up Max. Ripple &
Loading OCP OVP Efficiency Connector
Model DC regul. time Power Noise
[A] [A] [V] [%] [mm]
[V] [%] [ms] [W] [mV] p-p
CE
LVD 2014/35/EU
EN 60950-1:2006+A11+A1+A12+A2
www.sunny-euro.com
Wall mount SYS1381-Wxx series 6W~12W
Europe / Korea type (W2E/W2K) US / Canada type (W2) Australia type (W2A) UK type (W3U)
Cable specification:
www.sunny-euro.com
Wall mount SYS1530-Wxx series 8W~12W
GREEN MODE RoHS
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1530-1005-Wxx 5 0~2.0 10 150 2.1x5.5x11
SYS1530-0906-Wxx 6 0~1.5 9 150 2.1x5.5x11
SYS1530-0808-Wxx 7,5 0~1.0 8 180 2.1x5.5x11
SYS1530-0909-Wxx 9 0~1.0 9 180 2.1x5.5x11
SYS1530-1212-Wxx 12 0~1.0 12 180 2.1x5.5x11
SYS1530-1215-Wxx 15 0~0.8 12 200 2.1x5.5x11
SYS1530-1218-Wxx 18 0~0.66 12 200 2.1x5.5x11
SYS1530-1224-Wxx 24 0~0.5 12 240 2.1x5.5x11
Features:
PSU housing ready for use in country : Wxx = W2E - Europe | W2 - USA, Canada, Japan
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max @ AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle) 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal) Meet CEC,DOE,ERP,MEPS Level VI
SAFETY
0.4v dv max At AC nominal input loading from 50% load to
Transient response max load or peak load UL | GS | CB | CE | FCC |BSMI | PSE
(dv,tmax) 16ms tmax | Dynamic rise time 10uS max , duty 40mS max ,
Dynamic load step is slew rate of 0.5A/uS OTHERS
Power out.Limit Peak 13W Dielectric Strength(Hi-pot) Primary to Secondary:3000VAC 10mA/60S
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Less than 0.075W ms max. At AC nominal input@output min
Power consumption
load Cable Length 1370mm (4.5 feet) standard 2 wire cable or as required
INPUT PLD
Line power surge | Line voltage SAG-more info on request
(power line disturbance)
Voltage (90~264)VAC
Cooling method Natural Convection Cooling
Frequency (47~63)hz
Current 0.3A rms @ AC low line input and DC output full load Housing material PC
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature Temperature coefficient: < ±0.5% / °C
www.sunny-euro.com
Wall mount SYS1530-Wxx series 8W~12W
Cable specification:
www.sunny-euro.com
Wall mount SYS1888-Wxx/T2 series 18W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1888-1505 5 0~3.0 15 200 2.1x5.5x11
Features:
Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | T2 - Desktop
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT EMC
Turn delay 3000ms max@AC low line input@output full load
EMI 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load
EMS 2014/35/EU EN60950-1 : 2006 + A11 + A1 + A12 + A2
Efficiency (Normal) >84.3%@115v/60HZ,230V/50HZ input &Full load
0.4V dv max At AC nominal input loading from 20%load to 80%
SAFETY
Transient response load
CE | CB | TUV/GS | PSE | RCM | cTUVus | FCC | C-TICK | EAC
(dv,tmax) 16ms tmax Dynamic rise time 10 us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us OTHERS
Power out.Limit 18W Dielectric Strength
I/P-O/P:3000VAC
(Hi-pot)
Burn in limit 220VAC 80% Load (Ref) 4hours & 40°C + 5°C -0°C
50,000 Calculated Hours at 25ºC, according to the MIL-STD-
M.T.B.F
Power consumption 0.1W max. At AC nominal input@output min load 217F
www.sunny-euro.com
Wall mount SYS1888-Wxx/T2 series 18W
www.sunny-euro.com
Wall mount SYS1531-Wxx series 15W~24W
GREEN MODE RoHS
Dimension : 73 × 34 × 50 [mm]
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1531-1505-Wxx 5 0~3 15 150 2.1x5.5x11
SYS1531-1506-Wxx 6 0~2.5 15 150 2.1x5.5x11
SYS1531-1508-Wxx 7.5 0~2 15 180 2.1x5.5x11
SYS1531-1809-Wxx 9 0~2 18 180 2.1x5.5x11
SYS1531-2412-Wxx 12 0~2 24 180 2.1x5.5x11
SYS1531-2415-Wxx 15 0~1.6 24 200 2.1x5.5x11
SYS1531-2418-Wxx 18 0~1.33 24 200 2.1x5.5x11
SYS1531-2424-Wxx 24 0~1 24 280 2.1x5.5x11
Features:
PSU housing ready for use in country : Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan, Taiwan | W2A - Australia | W2C - China
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max @ AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle) 2014/35/EU
LVD
Meet CEC,DOE,ERP,MEPS Level EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal)
VI@115v/60HZ,230V/50HZ
SAFETY
0.4v dv max At AC nominal input loading from 50% load to
Transient response max load or peak load UL | GS | CB | CE | FCC | BSMI | PSE | SAA | RCM
(dv,tmax) 16ms tmax | Dynamic rise time 10uS max , duty 40mS max ,
Dynamic load step is slew rate of 0.5A/uS OTHERS
Power out.Limit Peak 28W Dielectric Strength(Hi-pot) Primary to Secondary:3000VAC 10mA/60S
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Less than 0.075W ms max. At AC nominal input@output min
Power consumption
load Cable Length 1800mm (6 feet) standard round cable or as required
INPUT PLD
Line power surge | Line voltage SAG-more info on request
(power line disturbance)
Voltage (90~264)VAC
Cooling method Natural Convection Cooling
Frequency (47~63)hz
Current 0.5A rms @ AC low line input and DC output full load Housing material PC
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature Temperature coefficient: < ±0.5% / °C
(cold start) 25°C @115Vac/230Vac nominal AC input
leakage current 0.25mA Max ENVIRONMENT
The power supply will self-protect any output to ground & auto Operating: 8%~90%RH / Storage: 5%~95% RH non condens-
Humidity
Over current/ recovery when abnormal circuit faults remove. An output short ing
Short protection circuit is defined as any output impedance less than 0.1
WEIGHT
ohms.
Over Voltage The power supply will be auto recovered when faults remove NW: 80g/pc
F1 1A/250V Fuse The power supply shall be protected
Input protection GW: 12kg/box
against power line surges and any abnormal condition
The power supply is provided with no load operation to
No Load protection PACKING
prevent the power supply and system from damage.
Protection class II, (ITU-T K.21 Surge 6KV on request) PE plastic bag 80 pcs /1 box
www.sunny-euro.com
Wall mount SYS1531-Wxx series 15W~24W
Europe type (W2E) UK type (W3U) US / Japan type (W2) Australia type (W2A) China type (W2C)
Cable specification:
www.sunny-euro.com
Wall mount SYS1529-Wxx series 12W
GREEN MODE RoHS
Efficiency level : V - VI
Approvals / Marks :
Features:
Dual USB inlet charger with Exchangeable AC Plugs.
Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz.
Customer can choose one or more from 5 AC plugs Wxx* (W2 - USA,Canada,Japan | W2A - Australia | W2C - China | W2E - Europe | W3U - England).
Output connector: dual USB inlet
Specification:
Voltage Max. Ripple
Efficiency OCP OVP Connector
Model DC Power & Noise
[%] [A] [V] [mm]
[V] [W] [mV]p-p max.
ErP V.
SYS1529-1205 5.0 75 2.5-3.0 max 10V 12 250 USB inlet
note Max load: 2.4A if 1 USB port is used / 1.2A if 2 USB ports are used
INPUT Current 0.3 A at AC low line input and DC output full load
Input surge current 40A/60A max at power supply cold start, ambient temperature 25℃@115Vac/230Vac nominal AC input.
Power Efficiency 74.74% minimum average efficiency in active mode (Meet CEC V)
Over Current The power supply will self-protect any output to ground.
PROTECTION Over Voltage The power supply will not be auto recovered when faults remove 110%-150%. (Voltage limit)
Is defined as any output impedance of less than 0.1Ω. The power supply will be auto recovered when short circuit faults
Short Circuit
remove.
Line regulation -9 % / +5%
www.sunny-euro.com
Wall mount SYS1529-Wxx series 12W
www.sunny-euro.com
Wall mount SYS1308-Wxx series 18W~24W
GREEN MODE RoHS
Dimension : 75 x 34 x 43 [mm]
Approvals / Marks :
Features:
PWMIC electrical design. For I.T.E. use only + RoHS conform.
Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz. Over load, over voltage & short protection.
Output connector: standard: 2.1x5.5x11 or customer requirement.
Available in versions: W2E(EU), W2(USA), W3U(UK), W2A (Australia), W2K(Korea), W2C (China).
Specification:
Voltage OVP Max. Ripple Connector
Loading Tol. OCP Efficiency
Model DC max Power & Noise UL Approved
[A] [%] [A] [%]
[V] [V] [W] [mV] p-p [mm]
SYS1308-1808-Wxx 7.5 0~2.40 ±5 3.0~5.5 16 >77.6 18 100 2.1x5.5x11
SYS1308-1809-Wxx 9 0~2.00 ±5 2.5~4.5 16 >77.6 18 100 2.1x5.5x11
SYS1308-2412-Wxx 12 0~2.00 ±5 3.5~5.5 16 >82 24 120 2.1x5.5x11
ErP V.
SYS1308-2415-Wxx 15 0~1.60 ±5 2.0~4.0 25 >82 24 150 2.1x5.5x11
SYS1308-2418-Wxx 18 0~1.33 ±5 2.0~4.0 25 >82 24 180 2.1x5.5x11
SYS1308-2424-Wxx 24 0~1.00 ±5 1.5~4.5 28 >82 24 240 2.1x5.5x11
ErP V. / CE only SYS1308-2448-Wxx 48 0~0.50 ±5 0.6~2.2 90 >82.1 24 480 2.1x5.5x11
Wxx Possible to order with Wxx = W2E - Europe | W2 - USA,Canada,Japan | W3U - UK | W2A - Australia | W2K - Korea | W2C - China
OEM Production This model is certified for Uout=(3,5,6,7.5,9,12,15,18,24,48)V and Pout=in steps(9,15,18,24)W
Voltage (90 ~ 264)VAC
Frequency (47 ~ 63)Hz
INPUT Current 1A rms@ AC low line input and DC output full load
Inrush Surge Current (cold start) 40/60Amax. @ power supply cold start, ambient temperature 25℃ @115Vac/230Vac nominal AC input.
Leakage current <0.25 mA @ 240VAC input
Over load OCP Fold back
Over Voltage OVP Voltage limiting
Yes, Output to Ground, Auto recovery when fault has been removed. Short Current & Over Current can not exceed 8A max. after
PROTECTION Short Circuit
1minute at nominal line input.
Protection class II.
No Load Operation Yes, to protect the power supply and system from damage
Dielectric Strength HI-POT B / I/P-O/P (FG): 3KVAC / 10mA / 1 minute
Set up time 3000 ms max. @ AC low line Input & Output full load
Hold-up Time 10ms @ AC nominal Input and Output full load
MTBF Qualification 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
OTHERS DC cable & connector Standard length of the cable 1,8m & It depends on customer requirements and upon specifications
Efficiency (Normal) >77.6% min. @ 240VAC input & Full load
Efficiency level V
Power Consumption Max. 0.3W @ AC nominal Input and Output min. load – ERP IV. / ERP V has <0.3W
Input Fuse 1A protected against power line surges and any abnormal conditions
Temperature Operating: (0 ~ 40)°C / Storage: (-20 ~ 85)°C
ENVIRONMENT
Humidity Operating: (8 ~ 90)% RH / Storage: (5 ~ 95)% RH non condensing
SAFETY CE | TUV/GS | CB | cULus | FCC | T-Licence| C-Tick| DOFT| BSMI| PSE |VCCI | CCC| PSB | KC
EMC 2014/30/EU
CE 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
WEIGHT 1pc N.W.: 150g / pc
0.48 x 0.26 x 0.44 [m]
PACKING Box 80pcs / 1box
G.W.: 16.8kg / box
www.sunny-euro.com
Wall mount SYS1308-Wxx series 18W~24W
Europe type (W2E) US / Japan type (W2) Australia type (W2A) UK type (W3U)
Cable specification:
www.sunny-euro.com
Wall mount SYS1449-Wxx series 15W~20W
GREEN MODE RoHS
Approvals / Marks :
Features:
Wall-mount power supply, single output. PSU housing ready for use in country :
Overload, over voltage & short protection. USA (type W2) Europe (type W2E)
For I.T.E. use only + RoHS conform. Australia (type W2A) China (type W2C)
Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz. UK (type W3U)
Specification:
Voltage Min. Max. Total OVP Max. Ripple & Connector
OCP Eff.
Model DC Load Load regul. max Power Noise UL approval
[A] [%]
[V] [A] [A] [%] [V] [W] [mV] p-p [mm]
SYS1449-1505-Wxx 5 0 3 ±5 3.4~7.0 9 15 >76 200 2.1x5.5x11
ErP V. SYS1449-1505-Wxx 5 0 3 ±5 3.4~7.0 9 15 >76 200 Micro USB
SYS1449-2005-Wxx 5 0 4 ±5 4.4~8.0 9 20 >78 200 2.1x5.5x11
OEP Production This model is certified for upon models only. Uout=5V / Pout=15W or 20W
Wxx Possible to order with Wxx = W2E - Europe | W2 - USA,Canada,Japan | W3U - UK | W2A - Australia | W2C - China
Turn on delay 3000 ms max @ AC low line input@output full load
Hold up time 8ms min @ AC nominal input@ output full load (> half cycle)
Efficiency (Normal) Minimum average efficiency in active mode
OUTPUT Transient response (dv, 1.2 dv max At AC nominal input loading from 50% load to max load or peak load.
tmax) 12ms t max Dynamic rise time 10uS max , duty 40mS max , Dynamic load step is slew rate of 0.5A/uS
Overshoot / Undershoot
more information will be provide on request
(δV , δT)
Burn in test Full load 2 Hours
Voltage (90 ~ 264)VAC
Frequency (47 ~ 63) Hz
Current 0.5A rms @ AC low line input and DC output full load
INPUT
Inrush Surge Current (cold start) 60A max @ At power supply cold start, ambient temperature 25℃@230Vac nominal AC input.
Leakage current 0.25 mA Max.
Power consumption <0.3W rms max. At AC nominal input@output min load
Over Current / The power supply will self-protect any output to ground, And auto recovery when abnormal circuit faults remove.
Short protection An output short circuit is defined as any output impedance of less than 0.1 ohms. Short current and over current can not exceed
(OCP) 8A max after 1 min. at nominal line input.
Over Voltage (OVP) The power supply will not be auto recovered when faults remove >>Voltage limit<<
PROTECTION
Input protection 1A Fuse - The power supply shall be protected against power line surges and any abnormal condition.
No load protection The power supply is provided with no load operation to prevent the power supply and system from damage.
Protection class II.
Dielectric Strength (Hi-pot) Primary to Secondary: 3000VAC / 10mA / 60s
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Cable length and type 1500mm (5feet) round cable, 1185#18*1C+SHIELD or depends on customer requirements
OTHERS PLD (power line disturbance ) LINE POWER SURGE | LINE VOLTAGE SAG – more information will be provide on request
Cooling method By natural air
Housing material PC or PPO
Temperature coefficient: < ±0.5% / °C
Temperature Operating: (0 ~ 40)°C / Storage: (-20 ~ 85)°C
ENVIRONMENT
Humidity Operating: 8% ~ 90% RH / Storage: 5% ~ 95% RH non condensing
SAFETY CE | TUV/GS | CB | FCC | cULus | PSE | BSMI
EMC 2014/30/EU
CE 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
WEIGHT 1pc N.W.: 139g / pc | G.W.: 155g / pc
0.38(L) x 0.44(W) x 0.23(H) [m]
PACKING Box 80 pcs / 1box
N.W.: 11.2kg/box | G.W.: 13.4 kg/box
www.sunny-euro.com
Wall mount SYS1449-Wxx series 15W~20W
Australia type (W2A) Europe type (W2E) US / Japan type (W2) UK type (W3U)
Cable specification:
www.sunny-euro.com
Wall mount SYS1541-Wxx series 15W~24W
GREEN MODE RoHS
Certified AC Plugs: EU, UK, USA/Japan, Aus, Korea, Brazil, Argentina, China, India, S. Africa
Approvals / Marks :
BIS
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1541-1505-Wxx* 5 0~3.0 15 180 2.1x5.5x11
SYS1541-1809-Wxx* 9 0~2.0 18 180 2.1x5.5x11
SYS1541-2412-Wxx* 12 0~2.0 24 180 2.1x5.5x11
SYS1541-2415-Wxx* 15 0~1.6 24 200 2.1x5.5x11
SYS1541-2418-Wxx* 18 0~1.33 24 240 2.1x5.5x11
SYS1541-2424-Wxx* 24 0~1.0 24 300 2.1x5.5x11
Features:
Certified plugs
Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | W2B - Brazil | W2G - Argentina | W2C - China | W2K - Korea | W2I - India | W3S - South Africa, India
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle)
LVD 2014/35/EU
EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal) Meet CEC,DOE,ERP,MEPS Level VI
SAFETY
0.4V dv max At AC nominal input loading from 20%load to
Transient response 80%load UL | GS | CB | CE | FCC | CCC | BSMI | EK-Mark (1505/2415/2412/2424) | SAA | RCM | PSB
(2412,2424) | EAC | INMETRO | BIS (2424) | PSE | S-Mark | STCOA
(dv,tmax)
16ms tmax Dynamic rise time 10us max,duty 40ms
OTHERS
Power out.Limit Peak 28w Dielectric Strength
Primary to Secondary:3000VAC 10mA/60S
(Hi-pot)
Burn in limit Full load 2 Hours
Less than 0.075W ms max. At AC nominal input@output min M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Power consumption
load
Cable Length 1500mm (5 feet) standard cable or as required
INPUT
PLD
Line power surge | Line voltage SAG-more info on request
Voltage (90~264)VAC (power line disturbance)
Frequency (47~63)hz Cooling method Natural Convection Cooling
Current 0.5A rms@AC low line input and DC output full load Housing material PC
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature Temperature coefficient: < ±0.5% / °C
www.sunny-euro.com
Wall mount SYS1541-Wxx series 15W~24W
UK type (W3U) China type (W2C) India type (W2I) South Africa, India type (W3S)
Cable specification:
1185#18*1C | 1500mm
www.sunny-euro.com
Wall mount SYS1357-Wxx series 15W~24W
GREEN MODE RoHS
Certified AC Plugs: EU, UK, USA/Japan, Aus, Korea, Brazil, Argentina, China, India, S. Africa
Approvals / Marks :
Features:
Wall-mount Adapter with Exchangeable AC Plugs. For I.T.E. use only + RoHS conform.
Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz.
Customer can choose one or more from 7 certified plugs Wxx*(W2E, W2, W3U, W2A, W2K, W2B, W2G, W2C, W2I, W3S).
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement.
Specification:
Voltage Max. Connector
Loading OCP OVP Efficiency Ripple / Noise
Model DC Power UL approved
[A] [A] [V] [%] [mV] p-p
[V] [W] [mm]
SYS1357-1505-Wxx* 5 0~3.00 3.6~7.0 6.0~ 9.3 >76.00 15 120 2.1x5.5x11
ErP V.
Wxx =W2E--Europe | W2--USA, Canada, Japan | W3U--UK | W2A--Australia | W2K--Korea | W2B--Brazil | W2G--Argentina |
*Wxx Possible to order with
W2C--China | W2I--India | W3S--South Africa
OEM production This model is certified for Uout[V] / Pout[W] = (5, 9, 15, 18, 24)V & (5~15W, 5~18, 5~24, 5~24, 5~24)W by step of 1W
INPUT Current 1A rms@ AC low line input and DC output full load
Inrush Current (cold start) 40/60Amax. @ power supply cold start, ambient temperature 25℃ @115Vac/230Vac nominal AC input.
Over Current The power supply will be auto recovered when over current faults remove. (Fold back)
PROTECTION Over Voltage The power supply will not be auto recovered when faults remove 110%-150%. (Voltage limit)
Short Circuit Is defined as any output impedance of less than 0.1Ω. The power supply will be auto recovered when short circuit faults remove.
Line regulation ±5 %
Input Plugs: EU, UK, US, AUS, China, Korea , Brazil, Argentina --- (exchangeable)
CONNECTION
Output Plug standard center ‘+’ or customer requirement // Cable length 1,8m or 1,37m(5V/3A)
SAFETY CE | GS | UL | CB | S-Mark | PSE | FCC | CCC | VCCI | BSMI | KC | T-Mark | C-Tick | PSB | RCM | GOST-R | EAC | INMETRO
EN 55022 Class B (2006)+ A1(2007)
EMI
EN 61000-3-2 (2006) + A1(2009) + A2 Class A(2009)/EN 61000-3-3 (2008)
EMC EN55024(1998)+A1(2001)+A2(2003) | IEC 61000-4-2 (2008) | IEC 61000-4-3 (2006) + A1(2007) + A2(2010)
EMS IEC 61000-4-4 (2004) + A1(2010) | IEC 61000-4-5 (2005) | IEC 61000-4-6 (2008) | IEC 61000-4-8 (2009)
IEC 61000-4-11 (2004)
www.sunny-euro.com
Wall mount SYS1357-Wxx series 15W~24W
Cable specification:
2468#18*2C | 1370mm
www.sunny-euro.com
Wall mount SYS1308 special 24W
GREEN MODE RoHS
Dimension : 75 x 34 x 43 [mm]
Approvals / Marks :
Features:
PWMIC electrical design.
Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz + S/T AC input cable 0.5m.
Over load, over voltage & short protection.
Output connector: standard: 2.1x5.5x11 or customer requirement.
For I.T.E. use only + RoHS conform.
Specification:
Voltage Max. Ripple &
Loading Tol. OCP OVP Efficiency Connector UL
Model DC Power Noise
[A] [%] [A] [V] [%] approved [mm]
[V] [W] [mV] p-p
ErP V. SYS1308-2412-special 12 0.05~2 ±5 3.0~8.0 16max >82 24 120 2.1x5.5x11
Voltage (90 ~ 264) VAC
Frequency (47 ~ 63) Hz
Current 1A rms @ 230VAC At AC low line input and DC output full load
Surge Current max. 40A/60Amax. At power supply cold start, ambient temperature 25℃@115VAC / 230VAC nominal AC input.
INPUT Leakage current <0.25 mA @ 240Vac input
Power Consumption Max. 0.3W @ AC nominal Input and Output min. load
Hold-up Time 10ms @ AC nominal Input and Output full load
Input AC cable Standard length: 0.5m; Material: H03VVH2-F 2*0.75mm2 (UL approval); Double insulation
Over load OCP Fold back
Over Voltage OVP Voltage limiting
Short Circuit The power supply will self-protect any output to ground, And auto recovery when abnormal circuit faults remove.
PROTECTION An output short circuit is defined as any output impedance of less than 0.1 ohms.
Input Protection 1A Fuse | The power supply shall be protected against power line surges and any abnormal condition.
Protection class II.
No Load Operation Yes, The power supply is provided with noload operation to prevent the power supply and system from damage.
Dielectric Strength HI-POT B | I/P-O/P (FG): 3KVAC | 10mA @ 1 minute
Output transient response (dv , 0.3v dv max
tmax)
16ms t max
Power output limit Peak27W
Turn on delay 7000ms max. @ AC low line Input & Output full load
DC output regulation U=12V, Loading: min 0A – max 2.7A peak, total regulation: 5%, 15s max. at AC nominal input & output 2.7A
MTBF Qualification 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
OTHERS DC cable & connector Standard length of the cable 1.8m (18AWGX2C) & It depends on customer requirements and upon specifications
Efficiency (Normal) >82% min. @ 240VAC input & Full load
PLD (power line disturbance) Line power surge: The power supply shall meet its specification with a rise in AC voltage to 120% of maximum rated line
voltage (288 voltage for 100-240 VAC operation) for a maximum of 20ms at 50Hz and 16ms at 60Hz.
The surge is to be applied five times with an internal of one minute between surges.
Line Voltage SAG: The power supply shall continue to meet its specifications with a line voltage drop (and subsequent return to
minimum rated voltage) to 68 VAC with a total power sag cycle time of 20 ms (rise and fall time shell equal 10 ms each).
Cooling By natural air
Temperature Operating: (0 ~ 40)°C | Storage: (-20 ~ 85)°C | Temperature coefficient: <±5%/°C
ENVIRONMENT Humidity Operating: (8 ~ 90)% RH | Storage: (5 ~ 95)% RH non condensing
SAFETY CE
EMC 2014/30/EU
CE LVD 2014/35/EU
EN 60950-1:2006+A11+A1+A12+A2
WEIGHT 1pc N.W.: 168g / pc | G.W.: 188g / pc
0.48 x 0.26 x 0.44 [m]
PACKING Box 56pcs / 1box
G.W.: 11.9 kg / box
www.sunny-euro.com
Wall mount SYS1308 special 24W
Cable specification:
B) AC-input :
www.sunny-euro.com
Wall mount SYS1452-Wxx series 30W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
Features:
Output connector: standard: 2.1 x 5.5 x 9.5mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 7000 ms max @ AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle) 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal) Meet CEC, ERP Level V @115v/60HZ,230V/50HZ
SAFETY
0.3v dv max At AC nominal input loading from 50% load to
Transient response max load or peak load GS | CB | CE
(dv,tmax) 8ms tmax | Dynamic rise time 10uS max , duty 40mS max ,
Dynamic load step is slew rate of 0.5A/uS
OTHERS
Power out.Limit -
Dielectric Strength(Hi-pot) Primary to Secondary:3000VAC 10mA/60S
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Less than 0.03W rms max. At AC nominal input@output no
Power consumption
load
Cable Length 1800mm (6 feet) standard cable or as required
INPUT
PLD
Line power surge | Line voltage SAG-more info on request
Voltage (90~264)VAC (power line disturbance)
Housing material PC
Current 1A rms @ AC low line input and DC output full load
Inrush Surge Current 30/60A max@power supply cold start,ambient temperature Temperature coefficient: < ±0.5% / °C
(cold start) 25°C @115Vac/230Vac nominal AC input
The power supply will self-protect any output to ground and Operating: 8%~90%RH / Storage: 5%~95% RH non condens-
Humidity
Over current/ auto recovery when abnormal circuit faults remove. An output ing
Short protection short circuit is defined as any output impedance of less than
0.1 ohms. WEIGHT
Over Voltage The power supply will be auto recovered when faults remove
1PC NW: 174g/pc
2.0AL/250V Fuse. F2 connected from MOV(Varistor) to
Input protection remaining PS circuitry to protect PS from excessive current GW: 12,6kg/box
draw.
The power supply is provided with no load operation to PACKING
No Load protection
prevent the power supply and system from damage.
Protection class II, (ITU-T K.21 Surge 6KV on request) PE plastic bag 64 pcs /1 box
www.sunny-euro.com
Wall mount SYS1452-Wxx series 30W
Cable specification:
www.sunny-euro.com
Wall mount SYS1588-Wxx series 20W~30W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1588-2005-Wxx* 5 0~4 20 120 2.1x5.5x11
SYS1588-2406-Wxx* 6 0~4 24 120 2.1x5.5x11
SYS1588-3009-Wxx* 9 0~3.33 30 120 2.1x5.5x11
SYS1588-3012-Wxx* 12 0~2.5 30 200 2.1x5.5x11
SYS1588-3015-Wxx* 15 0~2.0 30 200 2.1x5.5x11
SYS1588-3018-Wxx* 18 0~1.66 30 240 2.1x5.5x11
SYS1588-3024-Wxx* 24 0~1.25 30 240 2.1x5.5x11
SYS1588-3048-Wxx* 48 0~0.63 30 400 2.1x5.5x11
Features:
Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | W2C - China | W2K - Korea
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load
LVD 2014/35/EU
Efficiency (Normal) >85%@115v/60HZ,230V/50HZ input &Full load EN 60950-1:2006+A11+A1+A12+A2
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Current 1.5A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling
PROTECTION ENVIRONMENT
The power supply will be auto recovered when over current or Temperature Operating: 0~40℃ / Storage: -20~85℃
Over current/ short circuit faults remove (fold back). Is defined as any output
Short protection impedance of less than 0.1Ω.The power supply will be auto Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
recovered when short circuit faults remove
The power supply will not be auto recovered when faults remove
WEIGHT
Over Voltage
110%-150%. (Voltage limit) NW: 173g/pc + plug
F1:2A 250V Fuse The power supply shall be protected against
Input protection GW: 193g/pc + plug
power line surges and any abnormal condition
The power supply is provided with no load operation to prevent
No Load protection PACKING
the power supply and system from damage.
Protection class II, (ITU-T K.21 Surge 6KV on request) Box 75 pcs/1 box
www.sunny-euro.com
Wall mount SYS1588-Wxx series 20W~30W
Cable specification:
www.sunny-euro.com
Wall mount SYS1588-Wxx series 30W~40W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1588-3005-Wxx* 5 0~6 30 120 2.1x5.5x11
SYS1588-3609-Wxx* 9 0~4 36 120 2.1x5.5x11
SYS1588-4012-Wxx* 12 0~3.3 40 200 2.1x5.5x11
SYS1588-4015-Wxx* 15 0~2.6 40 200 2.1x5.5x11
SYS1588-4018-Wxx* 18 0~2.2 40 240 2.1x5.5x11
SYS1588-4024-Wxx* 24 0~1.6 40 240 2.1x5.5x11
SYS1588-4048-Wxx* 48 0~0.8 40 400 2.1x5.5x11
Features:
Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | W2C - China | W2K - Korea
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load
LVD 2014/35/EU
Efficiency (Normal) >87%@115v/60HZ,230V/50HZ input &Full load EN 60950-1:2006+A11+A1+A12+A2
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Current 1.5A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature 25°C Housing material PC + ABS
(cold start) @115Vac/230Vac nominal AC input
Temperature coefficient: < ±0.5% / °C
leakage current 0.25mA Max
PROTECTION ENVIRONMENT
The power supply will be auto recovered when over current or Temperature Operating: 0~40℃ / Storage: -20~85℃
Over current/ short circuit faults remove (fold back). Is defined as any output
Short protection impedance of less than 0.1Ω.The power supply will be auto Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
recovered when short circuit faults remove
The power supply will not be auto recovered when faults remove WEIGHT
Over Voltage
110%-150%. (Voltage limit)
NW: 173g/pc + plug
F1:2A 250V Fuse The power supply shall be protected against
Input protection
power line surges and any abnormal condition GW: 193g/pc + plug
The power supply is provided with no load operation to prevent
No Load protection
the power supply and system from damage. PACKING
Protection class II, (ITU-T K.21 Surge 6KV on request) Box 75 pcs/1 box
www.sunny-euro.com
Wall mount SYS1588-Wxx series 30W~40W
Cable specification:
www.sunny-euro.com
Wall mount SYS1621-Wxx series 30-60W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Features:
PSU housing ready for use in country : Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan (fixed) | W2A - Australia | W2G - Argentina | W2K - Korea
Output connector: Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty | Power delivery
OUTPUT CE
Turn delay 5000 ms max @ AC low line input@output full load EMC 2014/30/EU
Hold up time 10ms min@AC nominal input@output full load (>half cycle) 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
Meet CEC,DOE,ERP,MEPS Level
Efficiency (Normal)
VI@115v/60HZ,230V/50HZ SAFETY
0.4v dv max At AC nominal input loading from 50% load to
Transient response max load or peak load CE | FCC
(dv,tmax) 16ms tmax | Dynamic rise time 10uS max duty 40mS max ,
Dynamic load step is slew rate of 0.5A/uS OTHERS
Power out.Limit 30-60W based on the model
Dielectric Strength(Hi-pot) Primary to Secondary:3000VAC 10mA/60S
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
0.075W for Type C 30W and 45W
Power consumption
0.15W for Type C 60W DC output Type C
INPUT PLD
Line power surge | Line voltage SAG-more info on request
(power line disturbance)
Voltage (90~264)VAC
Cooling method Natural Convection Cooling
Frequency (47~63)hz
Housing material PC
Current 1.5A rms @ AC low line input and DC output full load
Temperature coefficient: <±0.5%/℃
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature
(cold start) 25°C @115Vac/230Vac nominal AC input
ENVIRONMENT
leakage current 0.25mA Max
Temperature Operating: 0~40℃ / Storage: -20~85℃
PROTECTION
Operating: 8%~90%RH / Storage: 5%~95% RH non condens-
The power supply will self-protect any output to ground & Humidity
ing
Over current/ auto recovery when abnormal circuit faults remove. An
Short protection output short circuit is defined as any output impedance less WEIGHT
than 0.1 ohms.
NW: 150g/pc
Over Voltage The power supply will be auto recovered when faults remove
www.sunny-euro.com
Wall mount SYS1621-Wxx series 30-60W
www.sunny-euro.com
Wall mount SYS1621-W2E series 30-60W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Voltage DC/Loading Max. Power Ripple / Noise
Model Connector
[V/A] [W] [mV] p-p
SYS1621-C30 5V/3A, 9V/3A, 12V/2.5A, 15V/2A, 20V/1.5A 30 150 USB-C
Features:
PSU housing ready for use in country : Wxx = W2E - Europe
Output connector: Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty | Power delivery
OUTPUT CE
Turn delay 5000 ms max @ AC low line input@output full load EMC 2014/30/EU
Hold up time 10ms min@AC nominal input@output full load (>half cycle) 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
Meet CEC,DOE,ERP,MEPS Level
Efficiency (Normal)
VI@115v/60HZ,230V/50HZ SAFETY
0.4v dv max At AC nominal input loading from 50% load to
Transient response max load or peak load CE
(dv,tmax) 16ms tmax | Dynamic rise time 10uS max , duty 40mS max ,
Dynamic load step is slew rate of 0.5A/uS OTHERS
Power out.Limit 30-60W based on the model
Dielectric Strength(Hi-pot) Primary to Secondary:3000VAC 10mA/60S
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
0.075W for Type C 30W and 45W
Power consumption
0.15W for Type C 60W DC output Type C
INPUT PLD
Line power surge | Line voltage SAG-more info on request
(power line disturbance)
Voltage (90~264)VAC
Cooling method Natural Convection Cooling
Frequency (47~63)hz
Housing material PC
Current 1.5A rms @ AC low line input and DC output full load
Temperature coefficient: <±0.5%/℃
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature
(cold start) 25°C @115Vac/230Vac nominal AC input
ENVIRONMENT
leakage current 0.25mA Max
Temperature Operating: 0~40℃ / Storage: -20~85℃
PROTECTION
Operating: 8%~90%RH / Storage: 5%~95% RH non condens-
The power supply will self-protect any output to ground & auto Humidity
ing
Over current/ recovery when abnormal circuit faults remove. An output short
Short protection circuit is defined as any output impedance less than 0.1 WEIGHT
ohms.
NW: 150g/pc
Over Voltage The power supply will be auto recovered when faults remove
www.sunny-euro.com
Wall mount SYS1621-W2E series 30-60W
www.sunny-euro.com
Desktop PoE-M3 series 12~24W
GREEN MODE RoHS
Approvals / Marks :
Features:
LAN Activity Indicator: Detects if LAN is connected to device
Specification:
Model PoE-1215-M3 PoE-2424-M3
Size (L*W*H) 85 x 43 x 30 [mm] 85 x 55 x 33 [mm]
Input Current: 0.3A @120VAC, 0.2A @230VAC 0.3A @120VAC, 0.2A @230VAC
Inrush Current: <15A peak @120VAC, <30A peak <15A peak @120VAC, <30A peak
Short Circuit The adapter shall not damage by short the DC output to ground The adapter shall not damage by short the DC output to ground
Peak Load Current Max. 1.1A (time <60sec) Max 1.3A (time <60sec)
Hold-up Time 10mS at typical input voltage and full load 10mS at typical input voltage and full load
Turn-on Delay 3sec at typical input voltage and load current 3sec at typical input voltage and load current
Over Voltage Protection Typ. 16.5V, Max 19.5V Typ. 27.6V, Max. 32V
80% Current Indicator Power LED will change color Power LED will change color
Temperature Operating: (0 ~ 40)°C / Storage: (-20 ~ 85)°C Operating: (0 ~ 40)°C / Storage: (-20 ~ 85)°C
WEIGHT / 1pc N.W.: 0,092kg / pc | G.W.: 0,105kg / pc N.W.: 0,135kg / pc | G.W.: 0,148kg / pc
www.sunny-euro.com
Desktop PoE-M3 series 12~24W
www.sunny-euro.com
Desktop SYS1001-T2 series 5W~6W
GREEN MODE RoHS
Dimension : 93 x 50 x 33 [mm]
VI
Approvals / Marks :
Specifications
Features:
Available in inlet version: C7 (T2)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load
LVD 2014/35/EU
Efficiency (Normal) >72%@115v/60HZ,230V/50HZ input &Full load EN 60950-1:2006+A11+A1+A12+A2
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Current 0.5A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling
Inrush Surge Current 30/40A max@power supply cold start,ambient temperature 25°C Housing material PC + ABS
(cold start) @115Vac/230Vac nominal AC input
leakage current 0.25mA Max Temperature coefficient: < ±0.5% / °C
PROTECTION ENVIRONMENT
The power supply will be auto recovered when over current or
Temperature Operating: 0~40℃ / Storage: -20~85℃
Over current/ short circuit faults remove (fold back). Is defined as any output
Short protection impedance of less than 0.1Ω.The power supply will be auto Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
recovered when short circuit faults remove
The power supply will not be auto recovered when faults remove WEIGHT
Over Voltage
110%-150%. (Voltage limit)
NW: 98g/pc
F1:1A 250V Fuse The power supply shall be protected against
Input protection
power line surges and any abnormal condition GW:115g/pc
The power supply is provided with no load operation to prevent
No Load protection
the power supply and system from damage.
PACKING
Protection class II Box 100 pcs/1 box
www.sunny-euro.com
Desktop SYS1001-T2 series 5W~6W
Cable specification:
www.sunny-euro.com
Desktop SYS1001-T3 series 5W~6W
GREEN MODE RoHS
Dimension : 93 x 50 x 33 [mm]
VI
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1001-0505-T3 5 0~1.0 5 150 2.1x5.5x11
Features:
Available in inlet version: C13 (T3)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load
LVD 2014/35/EU
Efficiency (Normal) >72%@115v/60HZ,230V/50HZ input &Full load EN 60950-1:2006+A11+A1+A12+A2
0.4V dv max At AC nominal input loading from 20%load to 80% SAFETY
Transient response load
(dv,tmax) cUL | FCC | GS | CE | CB | RCM | EAC | BSMI | PSE | VCCI
16ms tmax Dynamic rise time 10 us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us
OTHERS
Power out.Limit 6W
Dielectric Strength
I/P-O/P:3000VAC
Burn in limit Full load 2 Hours (Hi-pot)
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Current 0.5A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling
Inrush Surge Current 30/40A max@power supply cold start,ambient temperature 25°C Housing material PC + ABS
PROTECTION ENVIRONMENT
The power supply will be auto recovered when over current or Temperature Operating: 0~40℃ / Storage: -20~85℃
Over current/
short circuit faults remove (fold back). Is defined as any output
Short protection Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
impedance of less than 0.1Ω.The power supply will be auto
The power supply will not be auto recovered when faults remove
WEIGHT
Over Voltage
110%-150%. (Voltage limit) NW: 98g/pc
F1:1A 250V Fuse The power supply shall be protected against
Input protection GW:115g/pc
power line surges and any abnormal condition
The power supply is provided with no load operation to prevent
No Load protection PACKING
the power supply and system from damage.
Protection class I Box 100 pcs/1 box
www.sunny-euro.com
Desktop SYS1001-T3 series 5W~6W
Cable specification:
www.sunny-euro.com
Desktop SYS1001-T2 series 7.26W~12W
GREEN MODE RoHS
Dimension : 93 x 50 x 33 [mm]
VI
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1001-0703-T2 3,3 0~2.2 7.26 120 2.1x5.5x11
SYS1001-1105-T2 5 0~2.1 10 120 2.1x5.5x11
SYS1001-1108-T2 7,5 0~1.6 11 120 2.1x5.5x11
SYS1001-0909-T2 9 0~1.33 9 120 2.1x5.5x11
SYS1001-1212-T2 12 0~1.0 12 200 2.1x5.5x11
SYS1001-1215-T2 15 0~0.8 12 200 2.1x5.5x11
SYS1001-1218-T2 18 0~0.66 12 240 2.1x5.5x11
SYS1001-1224-T2 24 0~0.5 12 240 2.1x5.5x11
Features:
Available in inlet version: C7 (T2)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load
LVD 2014/35/EU
Efficiency (Normal) >80%@115v/60HZ,230V/50HZ input &Full load
0.4V dv max At AC nominal input loading from 20%load to 80% SAFETY
Transient response load
(dv,tmax) 16ms tmax Dynamic rise time 10 us max,duty 40ms cUL | FCC | GS | CE | CB | RCM | EAC | BSMI | PSE | VCCI
max,Dynamic load step is slew rate of 0.5A/us
OTHERS
Power out.Limit 12W
Dielectric Strength
I/P-O/P:3000VAC
Burn in limit Full load 2 Hours (Hi-pot)
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
INPUT
Cable Length 1370mm (4.5 feet) standard cable or as required
Voltage (90~264)VAC
PLD
Frequency (47~63)hz Line power surge | Line voltage SAG-more info on request
(power line disturbance)
Current 0.5A rms@AC low line input and DC output full load
Cooling method Natural Convection Cooling
Inrush Surge Current 30/40A max@power supply cold start,ambient temperature 25°C
(cold start) @115Vac/230Vac nominal AC input Housing material PC + ABS
www.sunny-euro.com
Desktop SYS1001-T2 series 7.26W~12W
Cable specification:
www.sunny-euro.com
Desktop SYS1001-T3 series 7.26W~12W
GREEN MODE RoHS
Dimension : 93 x 50 x 33 [mm]
VI
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1001-0703-T3 3,3 0~2.2 7.26 120 2.1x5.5x11
SYS1001-1105-T3 5 0~2.1 10 120 2.1x5.5x11
SYS1001-1108-T3 7.5 0~1.6 11 120 2.1x5.5x11
SYS1001-0909-T3 9 0~1.33 9 120 2.1x5.5x11
SYS1001-1212-T3 12 0~1.0 12 200 2.1x5.5x11
SYS1001-1215-T3 15 0~0.8 12 200 2.1x5.5x11
SYS1001-1218-T3 18 0~0.66 12 240 2.1x5.5x11
SYS1001-1224-T3 24 0~0.5 12 240 2.1x5.5x11
Features:
Available in inlet version: C13 (T3)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000ms max@AC low line input@output full load
EMC 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load
LVD 2014/35/EU
Efficiency (Normal) >80%@115v/60HZ,230V/50HZ input &Full load
0.4V dv max At AC nominal input loading from 20%load to 80% SAFETY
Transient response load
(dv,tmax) cUL | FCC | GS | CE | CB | RCM | EAC | BSMI | PSE | VCCI
16ms tmax Dynamic rise time 10 us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us OTHERS
Power out.Limit 12W
Dielectric Strength
I/P-O/P:3000VAC
Burn in limit Full load 2 Hours (Hi-pot)
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
INPUT
Cable Length 1370mm (4.5 feet) standard cable or as required
Voltage (90~264)VAC
PLD
Frequency (47~63)hz Line power surge | Line voltage SAG-more info on request
(power line disturbance)
Current 0.5A rms@AC low line input and DC output full load
Cooling method Natural Convection Cooling
Inrush Surge Current 30/40A max@power supply cold start,ambient temperature 25°C
(cold start) @115Vac/230Vac nominal AC input Housing material PC + ABS
leakage current 3.5mA Max Temperature coefficient: < ±0.5% / °C
PROTECTION
ENVIRONMENT
The power supply will be auto recovered when over current or
Over current/ short circuit faults remove (fold back). Is defined as any output Temperature Operating: 0~40℃ / Storage: -20~85℃
Short protection impedance of less than 0.1Ω.The power supply will be auto
Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
recovered when short circuit faults remove
The power supply will not be auto recovered when faults remove WEIGHT
Over Voltage
110%-150%. (Voltage limit)
NW: 98g/pc
F1:1A 250V Fuse The power supply shall be protected against
Input protection
power line surges and any abnormal condition GW:115g/pc
The power supply is provided with no load operation to prevent
No Load protection
the power supply and system from damage.
PACKING
Protection class I Box 100 pcs/1 box
www.sunny-euro.com
Desktop SYS1001-T3 series 7.26W~12W
Cable specification:
www.sunny-euro.com
Desktop SYS1544-T2 series 15W~24W
GREEN MODE RoHS
Dimension : 87 x 47 x 33 [mm]
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1544-1505-T2 5 0~3.0 15 180 2.1x5.5x11
SYS1544-1809-T2 9 0~2.0 18 180 2.1x5.5x11
SYS1544-2412-T2 12 0~2.0 24 180 2.1x5.5x11
SYS1544-2415-T2 15 0~1.6 24 200 2.1x5.5x11
SYS1544-2418-T2 18 0~1.33 24 240 2.1x5.5x11
SYS1544-2424-T2 24 0~1.0 24 300 2.1x5.5x11
Features:
Available in 2 inlet versions: C7 (T2) C13(T3)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle)
LVD 2014/35/EU
Meet CEC,DOE,ERP,MEPS Level VI EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal)
@115v/60HZ,230V/50HZ
SAFETY
0.4V dv max At AC nominal input loading from 20%load to
Transient response 80%load UL | GS | CB | CE | FCC | BSMI | PSE
(dv,tmax) 16ms tmax Dynamic rise time 10us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us OTHERS
Power out.Limit Peak 28w Dielectric Strength(Hi-
Primary to Secondary:3000VAC 10mA/60S
pot)
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Less than 0.075W ms max. At AC nominal input@output min
Power consumption
load Cable Length 1500mm (5 feet) standard cable or as required
INPUT PLD
Line power surge | Line voltage SAG-more info on request
(power line disturbance)
Voltage (90~264)VAC
Cooling method Natural Convection Cooling
Frequency (47~63)hz
Housing material PC
Current 1A rms@AC low line input and DC output full load
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature Temperature coefficient: < ±0.5% / °C
(cold start) 25°C @115Vac/230Vac nominal AC input
leakage current 0.25mA Max
ENVIRONMENT
Temperature Operating: 0~40℃ / Storage: -20~85℃
PROTECTION
The power supply will self-protect any output to ground & auto Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
Over current/
recovery when abnormal circuit faults remove. An output short
Short protection
circuit is defined as any output impedance less than 0.1 ohms. WEIGHT
Over Voltage The power supply will be auto recovered when faults remove NW: 180g/pc
F1:1A 250V Fuse The power supply shall be protected
Input protection GW: 11.5kg/box
against power line surges and any abnormal condition
The power supply is provided with no load operation to pre-
No Load protection PACKING
vent the power supply and system from damage.
Protection class II, (ITU-T K.21 Surge 6KV on request) PE plastic bag 60 pcs/1 box
www.sunny-euro.com
Desktop SYS1544-T2 series 15W~24W
Cable specification:
www.sunny-euro.com
Desktop SYS1544-T3 series 15W~24W
GREEN MODE RoHS
Dimension : 87 x 47 x 33 [mm]
Approvals / Marks :
BIS
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1544-1505-T3 5 0~3.0 15 180 2.1x5.5x11
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle) 2014/35/EU
LVD
Meet CEC,DOE,ERP,MEPS Level VI EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal)
@115v/60HZ,230V/50HZ SAFETY
0.4V dv max At AC nominal input loading from 20%load to
UL | GS | CB | CE | FCC | CCC | BSMI | PSE | EK-Mark (2412) | SAA | RCM | NOM (2412) |
Transient response 80%load
EAC | BIS (2412/1812/1512/1212) | S-MARK
(dv,tmax) 16ms tmax Dynamic rise time 10us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us OTHERS
Power out.Limit Peak 28w Dielectric Strength
Primary to Secondary:3000VAC 10mA/60S
(Hi-pot)
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Less than 0.075W ms max. At AC nominal input@output min
Power consumption
load Cable Length 1500mm (\5 feet) standard cable or as required
INPUT PLD
Line power surge | Line voltage SAG-more info on request
Voltage (90~264)VAC (power line disturbance)
Current 1A rms@AC low line input and DC output full load Housing material PC
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature Temperature coefficient: < ±0.5% / °C
(cold start) 25°C @115Vac/230Vac nominal AC input
leakage current 0.25mA Max ENVIRONMENT
PROTECTION Temperature Operating: 0~40℃ / Storage: -20~85℃
The power supply will self-protect any output to ground & auto
Over current/ Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
recovery when abnormal circuit faults remove. An output short
Short protection
circuit is defined as any output impedance less than 0.1 ohms. WEIGHT
Over Voltage The power supply will be auto recovered when faults remove
NW: 180g/pc
F1:1A 250V Fuse The power supply shall be protected
Input protection GW: 11.5kg/box
against power line surges and any abnormal condition
The power supply is provided with no load operation to pre-
No Load protection PACKING
vent the power supply and system from damage.
Protection class I, (ITU-T K.21 Surge 6KV on request) PE plastic bag 60 pcs/1 box
www.sunny-euro.com
Desktop SYS1544-T3 series 15W~24W
Cable specification:
www.sunny-euro.com
Desktop SYS1319-T2 series 30W
GREEN MODE RoHS
Approvals / Marks :
Features:
Wide range Input (90 ~ 264)VAC / (47 ~ 63) Hz. Over load, over voltage & short protection.
Designed and certified also for IEC320-C13 cable & inlet C14 (T3). Available for A.V. application
For I.T.E. use only + RoHS conform.
Specification:
Voltage OVP Max. Connector
Loading Tol. OCP Efficiency Ripple & Noise
Model DC max Power UL approved
[A] [%] [A] [%] [mV]p-p
[V] [V] [W] [mm]
SYS1319-3012-T2 12 0~2.50 ±5 3~8 16 >83.5 30 120 2.1x5.5x11
SYS1319-3015-T2 15 0~2.00 ±5 2.5~6.5 25 >80.6 30 150 2.1x5.5x11
ErP V. SYS1319-3018-T2 18 0~1.66 ±5 2.0~5.5 25 >87.0 30 180 2.1x5.5x11
SYS1319-3024-T2 24 0~1.25 ±5 1.5~5.5 25 >84.0 30 240 2.1x5.5x11
OEM Production This model is certified for Uout=(5,6,9,12,15,16,18,19,20,24)V and Pout=(5~30)W is rising in steps of 1W
Voltage (90 ~ 264) VAC
Frequency (47 ~ 63) Hz
INPUT Current 1A rms@ AC low line input and DC output full load
Surge Current max. 40/60Amax. @ power supply cold start, ambient temperature 25℃ @115Vac/230Vac nominal AC input.
www.sunny-euro.com
Desktop SYS1319-T2 series 30W
Cable specification:
www.sunny-euro.com
Desktop SYS1319-T3 series 30W
GREEN MODE RoHS
Approvals / Marks :
Features:
Wide range Input (90 ~ 264)VAC / (47 ~ 63) Hz. For I.T.E. use only + RoHS conform.
Over load, over voltage & short protection. Designed and certified also for cable IEC320-C7 & inlet C8 (T2).
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement.
Specification:
Voltage OVP Max. Ripple & Connector
Loading Tol. OCP Efficiency
Model DC Max Power Noise UL approved
[A] [%] [A] [%]
[V] [V] [W] [mV]p-p [mm]
SYS1319-3012-T3 12 0~2.50 ±5 3.0~8.0 16 >83.5 30 120 2.1x5.5x11
SYS1319-3015-T3 15 0~2.00 ±5 2.5~6.5 25 >80.6 30 150 2.1x5.5x11
ErP V.
SYS1319-3018-T3 18 0~1.66 ±5 2.0~5.5 25 >87.0 30 180 2.1x5.5x11
SYS1319-3024-T3 24 0~1.25 ±5 1.5~5.5 25 >84.0 30 240 2.1x5.5x11
OEM Production This model is certified for Uout=(5,6,9,12,15,16,18,19,20,24)V and Pout=(5~30)W is rising in steps of 1W
Voltage (90 ~ 264) VAC
Frequency (47 ~ 63) Hz
INPUT Current 1A rms@ AC low line input and DC output full load
Surge Current max. 40/60Amax. @ power supply cold start, ambient temperature 25℃ @115Vac/230Vac nominal AC input.
Leakage current 3.5mA Max.
Over load OCP > 120% Fold back
Over
OVP > 105% Voltage limiting
Voltage
Yes, Output to Ground, Auto recovery when fault has been removed. Short Current & Over Current can not exceed
PROTECTION Short Circuit
8A max. after 1minute at nominal line input.
Protection class I.
No Load Operation Yes, to protect the power supply and system from damage
Dielectric Strength I/P-O/P (FG): 3KVAC / 10mA / 1 min
Power ON Led Yes
Turn on delay 3000 ms max. @ AC low line input @ output full load
Hold-up Time 10ms @ AC nominal Input and Output full load
OTHERS MTBF Qualification 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
DC cable & connector Standard length of the cable 1,8m & It depends on customer requirements and upon specifications
Efficiency (typical) >83.5% @ 240VAC input & Full load
Power Consumption Max. 0.3Wrms @ AC nominal Input and Output min. load | some models have achieved efficiency level IV.
Input Fuse 250VAC / 1.6A protected against power line surges and any abnormal conditions
Temperature Operating: (0 ~ 40)°C / Storage: (-20 ~ 85)°C
ENVIRONMENT
Humidity Operating: (8 ~ 90)% RH / Storage: (5 ~ 95)% RH non condensing
SAFETY CE | TUV/GS | CB | cULus | KC
EMC 2014/30/EU
CE 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
WEIGHT 1pc N.W.: 200g / pc
0.48 x 0.26 x 0.44 [m]
PACKING Box 60 pcs / 1box
G.W.: 15kg / box
www.sunny-euro.com
Desktop SYS1319-T3 series 30W
Cable specification:
www.sunny-euro.com
Desktop SYS1588-T2 series 20W~30W
GREEN MODE RoHS
Dimension : 92 x 50 x 32 [mm]
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1588-2005-T2 5 0~4 20 120 2.1x5.5x11
SYS1588-2709-T2 9 0~3 27 120 2.1x5.5x11
SYS1588-3012-T2 12 0~2.5 30 200 2.1x5.5x11
SYS1588-3015-T2 15 0~2.0 30 200 2.1x5.5x11
SYS1588-3018-T2 18 0~1.66 30 240 2.1x5.5x11
SYS1588-3024-T2 24 0~1.25 30 240 2.1x5.5x11
SYS1588-3048-T2 48 0~0.63 30 400 2.1x5.5x11
Features:
Available in inlet version: C7 (T2)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
PROTECTION ENVIRONMENT
The power supply will be auto recovered when over current or Temperature Operating: 0~40℃ / Storage: -20~85℃
Over current/ short circuit faults remove (fold back). Is defined as any output
Short protection impedance of less than 0.1Ω.The power supply will be auto Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
recovered when short circuit faults remove
The power supply will not be auto recovered when faults remove
WEIGHT
Over Voltage
110%-150%. (Voltage limit) NW: 187g/pc
F1:2A 250V Fuse The power supply shall be protected against
Input protection
power line surges and any abnormal condition GW: 208g/pc
The power supply is provided with no load operation to prevent
No Load protection
the power supply and system from damage.
PACKING
Protection class II, (ITU-T K.21 Surge 6KV on request) Box 50 pcs/1 box
www.sunny-euro.com
Desktop SYS1588-T2 series 20W~30W
Cable specification:
www.sunny-euro.com
Desktop SYS1588-T3 series 20W~30W
GREEN MODE RoHS
Dimension : 92 x 50 x 32 [mm]
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1588-2005-T3 5 0~4 20 120 2.1x5.5x11
SYS1588-2709-T3 9 0~3 27 120 2.1x5.5x11
Features:
Available in inlet version: C13 (T3)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load
LVD 2014/35/EU
Efficiency (Normal) >85%@115v/60HZ,230V/50HZ input &Full load
0.4V dv max At AC nominal input loading from 20%load to 80% SAFETY
Transient response load
CE | GS | cTUVus | FCC | RCM | PSE | EAC | CB
(dv,tmax) 16ms tmax Dynamic rise time 10 us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us OTHERS
Power out.Limit 30W Dielectric Strength
I/P-O/P:3000VAC
Burn in limit Full load 2 Hours (Hi-pot)
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
www.sunny-euro.com
Desktop SYS1588-T3 series 20W~30W
Cable specification:
www.sunny-euro.com
Desktop SYS1546-T2 series 36W
GREEN MODE RoHS
Dimension : 99 x 50 x 33 [mm]
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1546-3612-T2 12 0~3.0 36 180 2.1x5.5x11
SYS1546-3615-T2 15 0~2.40 36 200 2.1x5.5x11
SYS1546-3618-T2 18 0~2.0 36 240 2.1x5.5x11
SYS1546-3619-T2 19 0~1.89 36 240 2.1x5.5x11
SYS1546-3624-T2 24 0~1.5 36 300 2.1x5.5x11
Features:
Available in 2 inlet versions: C7 (T2) C13(T3)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle)
LVD 2014/35/EU
Meet CEC,DOE,ERP,MEPS Level VI EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal)
@115v/60HZ,230V/50HZ
SAFETY
0.4V dv max At AC nominal input loading from 20%load to
Transient response 80%load UL | GS | CB | CE | FCC |SAA | RCM
(dv,tmax) 16ms tmax Dynamic rise time 10us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us OTHERS
Power out.Limit Peak 40w Dielectric Strength
Primary to Secondary:3000VAC 10mA/60S
(Hi-pot)
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Less than 0.075W ms max. At AC nominal input@output min
Power consumption
load Cable Length 1370mm (4.5 feet) standard cable or as required
INPUT PLD
Line power surge | Line voltage SAG-more info on request
(power line disturbance)
Voltage (90~264)VAC
Cooling method Natural Convection Cooling
Frequency (47~63)hz
Housing material PC
Current 1.5A rms@AC low line input and DC output full load
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature Temperature coefficient: < ±0.5% / °C
(cold start) 25°C @115Vac/230Vac nominal AC input
leakage current 0.25mA Max
ENVIRONMENT
Temperature Operating: 0~40℃ / Storage: -20~85℃
PROTECTION
The power supply will self-protect any output to ground & auto Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
Over current/
recovery when abnormal circuit faults remove. An output short
Short protection
circuit is defined as any output impedance less than 0.1 ohms. WEIGHT
Over Voltage The power supply will be auto recovered when faults remove NW: 166g/pc
F1:1A 250V Fuse The power supply shall be protected
Input protection GW: 10.5kg/box
against power line surges and any abnormal condition
The power supply is provided with no load operation to prevent
No Load protection PACKING
the power supply and system from damage.
Protection class II, (ITU-T K.21 Surge 6KV on request) PE plastic bag 60 pcs/1 box
www.sunny-euro.com
Desktop SYS1546-T2 series 36W
Cable specification:
www.sunny-euro.com
Desktop SYS1546-T3 series 36W
GREEN MODE RoHS
Dimension : 99 x 50 x 33 [mm]
Approvals / Marks :
BIS
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1546-3612-T3 12 0~3.00 36 180 2.1x5.5x11
SYS1546-3615-T3 15 0~2.40 36 200 2.1x5.5x11
SYS1546-3618-T3 18 0~2.0 36 240 2.1x5.5x11
SYS1546-3619-T3 19 0~1.89 36 240 2.1x5.5x11
SYS1546-3624-T3 24 0~1.5 36 300 2.1x5.5x11
Features:
Available in 2 inlet versions: C7 (T2) C13(T3)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle) 2014/35/EU
LVD
Meet CEC,DOE,ERP,MEPS Level VI EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal)
@115v/60HZ,230V/50HZ SAFETY
0.4V dv max At AC nominal input loading from 20%load to
UL | GS | CB | CE | FCC |CCC |BSMI | PSE | KC (only for 3612) |SAA | RCM | NOM (only for
Transient response 80%load
3612) | EAC | BIS (only for 3612/3615) |S-MARK
(dv,tmax) 16ms tmax Dynamic rise time 10us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us OTHERS
Power out.Limit Peak 40w Dielectric Strength
Primary to Secondary:3000VAC 10mA/60S
(Hi-pot)
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Less than 0.075W ms max. At AC nominal input@output min
Power consumption
load
Cable Length 1370mm (4.5 feet) standard cable or as required
INPUT PLD
Line power surge | Line voltage SAG-more info on request
Voltage (90~264)VAC (power line disturbance)
Current 1.5A rms@AC low line input and DC output full load Housing material PC
Inrush Surge Current 40/60A max@power supply cold start,ambient temperature Temperature coefficient: < ±0.5% / °C
(cold start) 25°C @115Vac/230Vac nominal AC input
leakage current 0.25mA Max ENVIRONMENT
The power supply will self-protect any output to ground & auto Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
Over current/
recovery when abnormal circuit faults remove. An output short
Short protection
circuit is defined as any output impedance less than 0.1 ohms. WEIGHT
Over Voltage The power supply will be auto recovered when faults remove
NW: 170g/pc
F1:1A 250V Fuse The power supply shall be protected
Input protection
against power line surges and any abnormal condition GW: 10.5kg/box
The power supply is provided with no load operation to prevent
No Load protection PACKING
the power supply and system from damage.
Protection class I, (ITU-T K.21 Surge 6KV on request) PE plastic bag 60 pcs/1 box
www.sunny-euro.com
Desktop SYS1546-T3 series 36W
Cable specification:
www.sunny-euro.com
Desktop SYS1588-T2 series 30W~40W
GREEN MODE RoHS
Dimension : 92 x 50 x 32 [mm]
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1588-3005-T2 5 0~6 30 120 2.1x5.5x11
SYS1588-3609-T2 9 0~4 36 120 2.1x5.5x11
SYS1588-4012-T2 12 0~3.3 40 200 2.1x5.5x11
SYS1588-4015-T2 15 0~2.6 40 200 2.1x5.5x11
SYS1588-4018-T2 18 0~2.2 40 240 2.1x5.5x11
SYS1588-4024-T2 24 0~1.6 40 240 2.1x5.5x11
SYS1588-4048-T2 48 0~0.8 40 400 2.1x5.5x11
Features:
Available in inlet version: C7 (T2)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load
LVD 2014/35/EU
Efficiency (Normal) >87%@115v/60HZ,230V/50HZ input &Full load EN 60950-1:2006+A11+A1+A12+A2
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
PROTECTION ENVIRONMENT
Temperature Operating: 0~40℃ / Storage: -20~85℃
The power supply will be auto recovered when over current or
Over current/
short circuit faults remove (fold back). Is defined as any output Humidity
Short protection Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
impedance of less than 0.1Ω.The power supply will be auto
The power supply will not be auto recovered when faults remove
WEIGHT
Over Voltage
110%-150%. (Voltage limit) NW: 187g/pc
F1:2A 250V Fuse The power supply shall be protected against
Input protection
power line surges and any abnormal condition GW: 208g/pc
The power supply is provided with no load operation to prevent
No Load protection
the power supply and system from damage.
PACKING
Protection class II, (ITU-T K.21 Surge 6KV on request) Box 50 pcs/1 box
www.sunny-euro.com
Desktop SYS1588-T2 series 30W~40W
Cable specification:
www.sunny-euro.com
Desktop SYS1588-T3 series 30W~40W
GREEN MODE RoHS
Dimension : 92 x 50 x 32 [mm]
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1588-3005-T3 5 0~6 30 120 2.1x5.5x11
Features:
Available in inlet version: C13 (T3)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 8ms min@AC nominal input@output full load
LVD 2014/35/EU
Efficiency (Normal) >87%@115v/60HZ,230V/50HZ input &Full load EN 60950-1:2006+A11+A1+A12+A2
Power consumption 0.1W max. At AC nominal input@output min load M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
www.sunny-euro.com
Desktop SYS1588-T3 series 30W~40W
Cable specification:
www.sunny-euro.com
Desktop SYS1548-T2 series 50W~65W
GREEN MODE RoHS
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1548-5012-T2 12 0~4.17 50 200 2.1x5.5x11
SYS1548-5024-T2 24 0~2.08 50 240 2.1x5.5x11
SYS1548-6512-T2 12 0~5.42 65 180 2.1x5.5x11
SYS1548-6512-T2 12 0~5.42 65 180 2.5x5.5x11
SYS1548-6512-T2 12 0~5.42 65 180 (*)
SYS1548-6515-T2 15 0~4.33 65 200 2.1x5.5x11
SYS1548-6518-T2 18 0~3.61 65 240 2.1x5.5x11
SYS1548-6519-T2 19 0~3.42 65 240 2.1x5.5x11
SYS1548-6524-T2 24 0~2.71 65 300 2.1x5.5x11
SYS1548-6536-T2 36 0~1.80 65 360 2.1x5.5x11
Features:
“E” - 4.2 x 6.0 x 10 CenterPINØ1.4mm (black) for LCD (DELL+LG)
“B” - 2.1 x 5.5 x 9.5 (black) for common use
mentioned or It will be provide with the specify model
(*) DC Connectors “M” - 2.5 x 5.5 x 11.5 (white) for LCD ACER
per request.
“D” - 3.0 x 6.3 x 9 (green) for LCD ACER
“Е” - 1.7 x 5.5 x 11.5 (yellow)
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle)
LVD 2014/35/EU
Efficiency (Normal) Meet CEC,DOE,ERP,MEPS Level VI@115v/60HZ,230V/50HZ
0.4V dv max At AC nominal input loading from 20%load to 80% SAFETY
Transient response load
(dv,tmax) UL | GS | CB | CE | FCC | SAA | RCM
16ms tmax Dynamic rise time 10 us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us OTHERS
Power out.Limit Peak 75w Dielectric Strength
Primary to Secondary:3000VAC 10mA/60S
Burn in limit Full load 2 Hours (Hi-pot)
Less than 0.075W ms max. At AC nominal input@output min M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Power consumption
load
Cable Length 1500mm (5 feet) standard cable or as required
INPUT
Voltage (90~264)VAC PLD Line power surge | Line voltage SAG-more info on request
Frequency (47~63)hz
Cooling method Natural Convection Cooling
Current 2.0A rms@AC low line input and DC output full load
Housing material PC or PPO
Inrush Surge Current 40/80A max@power supply cold start,ambient temperature 25°C
(cold start) @115Vac/230Vac nominal AC input Temperature coefficient: < ±0.5% / °C
leakage current T2:0.25mA max T3:3.0mA max
ENVIRONMENT
PROTECTION Temperature Operating: 0~40℃ / Storage: -20~85℃
The power supply will self-protect any output to ground & auto
Over current/ Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
recovery when abnormal circuit faults remove. An output short
Short protection
circuit is defined as any output impedance less than 0.1 ohms.
WEIGHT
Over Voltage The power supply will be auto recovered when faults remove
NW: 290g/pc
F1:3.15A 250V Fuse The power supply shall be protected
Input protection
against power line surges and any abnormal condition GW: 16kg/box
The power supply is provided with no load operation to prevent
No Load protection
the power supply and system from damage.
PACKING
Protection class II, (ITU-T K.21 Surge 6KV on request) PE plastic bag 60 pcs/1 box 48x44x23 cm
www.sunny-euro.com
Desktop SYS1548-T2 series 50W~65W
Cable specification:
a) UNI cable type (1185#16*1C + shield / 5FT) ---- types of UNI plugs can be changed by customer
“E” type: (4.2x6.0x10.0 CPØ1.4) “B” type: (2.1x5.5x9.5) “M” type: (2.5x5.5x11.5) “D” type: (3.0 x 6.3 x 9)
b) FIX cable type (1185#16 for 12V model, 1185#20 for 24V model)
www.sunny-euro.com
Desktop SYS1548-T3 series 50W~65W
GREEN MODE RoHS
Approvals / Marks :
BIS
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1548-5012-T3 12 0~4.17 50 200 2.1x5.5x11
SYS1548-5024-T3 24 0~2.08 50 240 2.1x5.5x11
SYS1548-6512-T3 12 0~5.42 65 180 2.1x5.5x11
SYS1548-6512-T3 12 0~5.42 65 180 2.5x5.5x11
SYS1548-6515-T3 15 0~4.33 65 200 2.1x5.5x11
SYS1548-6518-T3 18 0~3.61 65 240 2.1x5.5x11
SYS1548-6519-T3 19 0~3.42 65 240 2.1x5.5x11
SYS1548-6524-T3 24 0~2.71 65 300 2.1x5.5x11
SYS1548-6536-T3 36 0~1.80 65 360 2.1x5.5x11
Features:
Available in 2 inlet versions: C7 (T2) C13(T3)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 3000 ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle)
LVD 2014/35/EU
Meet CEC,DOE,ERP,MEPS Level EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal)
VI@115v/60HZ,230V/50HZ
SAFETY
0.4V dv max At AC nominal input loading from 20%load to
Transient response 80%load UL | GS | CB | CE | FCC |CCC |BSMI | PSE | EK-Mark (only for 5012) |SAA | RCM | NOM (only
(dv,tmax) 16ms tmax Dynamic rise time 10 us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us OTHERS
Power out.Limit Peak 75w Dielectric Strength
Primary to Secondary:3000VAC 10mA/60S
(Hi-pot)
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Less than 0.075W ms max. At AC nominal input@output min
Power consumption
load 1500mm (5 feet) standard cable or as required
Cable Length
INPUT 1200mm (4 feet) cable for SYS1548-5012-T3
PLD
Voltage (90~264)VAC Line power surge | Line voltage SAG-more info on request
(power line disturbance)
Frequency (47~63)hz Cooling method Natural Convection Cooling
Current 2.0A rms@AC low line input and DC output full load
Housing material PC or PPO
Inrush Surge Current 40/80A max@power supply cold start,ambient temperature
(cold start) 25°C @115Vac/230Vac nominal AC input Temperature coefficient: < ±0.5% / °C
www.sunny-euro.com
Desktop SYS1548-T3 series 50W~65W
Mechanical case
Cable specification:
FIX cable type (1185#16(for 12Vmodel) or 20(for 24V,48V model) or 18*1C + shield / 4FT(50W) or 5FT(65W))
www.sunny-euro.com
Desktop ATS065T-T3 series 65W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
ATS065T-P480-T3 48 0~1.36 65 480 2.1x5.5x11
Features:
Available in inlet version: C13 (T3)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Suitable for usage at Telecommunication, Computer, Industrial Controller, & OA System | 1 Year Warranty
OUTPUT EMC
Hold up time 10ms @ full load EMI Compliance to EN 55022 Class B, EN 61000-3-2,3
Less than 0.21W ms max. At AC nominal input@output min cUL | GS | CB | CE | PSE | BSMI | RCM
Power consumption
load
OTHERS
INPUT
Withstand Voltage AC 3000 V Primary - Secondary
Voltage (100~240)VAC
M.T.B.F 300,000 Hrs.(Calculated Hours At 25ºC By Telcordia SR-332)
Frequency (50~60)hz
Cable Length 1500mm (5 feet) Black UL1185 AWG22
Current 1.4A Max.
Cooling method Natural Convection Cooling
Inrush Surge Current 80A Max. / 240Vac
(cold start) (Cold start at 25 ºC, full load) Temperature coefficient: < ±0.5% / °C
Input protection Internal Primary Current Fuse, Inrush Limiting NW: 280g/pc
No Load operation Yes, to protect the power supply and system from damage PACKING
www.sunny-euro.com
Desktop ATS065T-T3 series 65W
Cable specification:
www.sunny-euro.com
Desktop SYS1575-90xx-M3 series 90W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1575-9012-M3 12 0~7.5 90 200 2.1x5.5x11
Features:
Available in inlet version: C5 (M3)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 7000ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 10ms min@AC nominal input@output full load (>half cycle) LVD 2014/35/EU
Efficiency (Normal) Meet CEC,DOE,ERP,MEPS Level VI@115v/60HZ,230V/50HZ
SAFETY
2V dv max At AC nominal input loading from 20%load to 80%load
Transient response UL | GS | CB | CE | FCC | SAA | RCM | T-licence
(dv,tmax) Dynamic rise time 10 us max,duty 40ms max,Dynamic load step is
slew rate of 0.5A/us OTHERS
Power out.Limit Peak 110w
Dielectric Strength (Hi-pot) Primary to Secondary:1500VAC 10mA/60S
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Power consumption Less than 0.21W ms max. At AC nominal input@output min load
Cable Length 1500mm (5 feet) standard cable or as required
INPUT
PLD
Line power surge | Line voltage SAG-more info on request
Voltage (90~264)VAC (power line disturbance)
www.sunny-euro.com
Desktop SYS1575-90xx-M3 series 90W
Cable specification:
www.sunny-euro.com
Desktop DRST-90xx-T3/M3 series 84W~90W
GREEN MODE RoHS
Approvals / Marks :
Features:
Wide range Input (100 ~ 240) VAC / (50 ~ 60) Hz. Desktop type with C6 inlet.
Overvoltage, Short Circuit & Over Current protection. Meets Safety Agency Requirements and Complies EMI/EMS
Leakage Current less than 3.5mA Regulated Output with Low Ripple Noise
For I.T.E. use only + RoHS conform.
Specification:
Voltage Line/Road Hold up Max. Connector
Loading Ripple & Noise
Model DC regulation time Power “Barel type”
[A] [V] p-p
[V] [%] [ms] [W] [mm]
DRST-8412-T3 (M3) 12 0~7.00 ±5 10 84 1~2% 2.1x5.5x10.5
DRST-9024-T3 (M3) 24 0~3.75 ±5 10 90 1~2% 2.1x5.5x10.5
Voltage (100 ~ 240)VAC
Protection Short circuit Protection ▪ Over Voltage Protection ▪ Over Current Protection
Efficiency DoE Level VI ▪ Energy Star ▪ ErP Stage 2 ▪ NRCan & GEMS Level VI Certified
SAFETY CB | CE | cULus | FCC | PSE | BSMI | RCM (approvals may vary with input plug type)
EMC 2014/30/EU
CE 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
www.sunny-euro.com
Desktop DRST-90xx-T3/M3 series 84W~90W
www.sunny-euro.com
Desktop SYS1576-M3 series 130W
GREEN MODE RoHS
Approvals / Marks :
Specifications
Voltage DC Loading Max. Power Ripple / Noise Connector
Model
[V] [A] [W] [mV] p-p [mm]
SYS1576-12012-M3 12 0~10.0 120 200 2.1x5.5x11
Features:
Available in inlet version: C5 (M3)
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT CE
Turn delay 7000ms max@AC low line input@output full load EMC 2014/30/EU
Hold up time 5ms min@AC nominal input@output full load (>half cycle) 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
Efficiency (Normal) Meet CEC,DOE,ERP,MEPS Level VI@115v/60HZ,230V/50HZ
SAFETY
1.2V dv max At AC nominal input loading from 20%load to 80%
Transient response load UL | GS | CB | CE | FCC | SAA | RCM | T-licence
(dv,tmax) Dynamic rise time 10 us max,duty 40ms max,Dynamic load step is
slew rate of 0.5A/us
OTHERS
Dielectric Strength
Power out.Limit Peak 150w Primary to Secondary:1500VAC 10mA/60S
(Hi-pot)
Burn in limit Full load 2 Hours
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Power consumption Less than 0.21W ms max. At AC nominal input@output min load
Cable Length 1500mm (5 feet) standard cable or as required
INPUT PLD
Voltage (90~264)VAC (power line disturb- Line power surge | Line voltage SAG-more info on request
ance)
Frequency (47~63)hz
Cooling method Natural Convection Cooling
Current 4A rms@AC low line input and DC output full load
Housing material PC or PPO
Inrush Surge Current 120A max@power supply cold start,ambient temperature 25°C
(cold start) @115Vac/230Vac nominal AC input Temperature coeffi-
< ±0.5% / °C
cient:
leakage current 3.5mA max
ENVIRONMENT
PROTECTION
Temperature Operating: 0~40℃ / Storage: -20~85℃
The power supply will self-protect any output to ground & auto
Over current/
recovery when abnormal circuit faults remove. An output short Humidity Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
Short protection
circuit is defined as any output impedance less than 0.1 ohms.
WEIGHT
Over Voltage The power supply will be auto recovered when faults remove
NW: 680 g/pc (estimated)
F1:6.3A 250V Fuse The power supply shall be protected against
Input protection
power line surges and any abnormal condition GW: 19 kg/box (estimated)
The power supply is provided with no load operation to prevent the
No Load protection PACKING
power supply and system from damage.
Protection class I, (ITU-T K.21 Surge 6KV on request) 25 pcs/1 box
www.sunny-euro.com
Desktop SYS1576-M3 series 130W
Cable specification:
for models with Voltage 12V-15V for models with Voltage 18V-54V
1185#14*1C+SHIELD|1500mm 1185#16*1C+SHIELD|1500mm
www.sunny-euro.com
Desktop DRST-120xx-T3 series max 120W
GREEN MODE RoHS
Approvals / Marks :
Features:
Regulated Output with Low Ripple Noise | Universal range 100 - 240VAC / 50~63Hz
Meet CEC, Energy Star & ERP Regulations No Load Power Consumption Less Than 0.5W
Over Voltage, Short Circuit & Over Current Protection
Leakage Current less than 3.5mA
I.T.E. Power Supply + RoHS conform.
Specification:
Voltage Connector
Loading Tolerance Max. Power Ripple & Noise
Model DC Barrel Type
[A] [%] [W] [mV] p-p
[V] [mm]
DRST-10812-T3 12 0~9.0 ±5 108 - 2.1x5.5x11
DRST-12015-T3 15 0~5.0 ±5 120 - 2.1x5.5x11
DRST-12016-T3 16 0~7.5 ±5 120 - 2.1x5.5x11
DRST-12018-T3 18 0~6.6 ±5 120 - 2.1x5.5x11
DRST-12019-T3 19 0~6.3 ±5 120 - 2.1x5.5x11
DRST-12020-T3 20 0~6.0 ±5 120 - 2.1x5.5x11
DRST-12024-T3 24 0~5.0 ±5 120 - 2.1x5.5x11
DRST-12030-T3 30 0~4.0 ±5 120 - 2.1x5.5x11
DRST-12048-T3 48 0~2.5 ±5 120 - 2.1x5.5x11
DRST-12056-T3 56 0~2.15 ±5 120 - 2.1x5.5x11
Voltage (100 ~ 240) VAC
Frequency (50 ~ 60) Hz
INPUT
Current (rms max) 1.6 A max.
Protection Internal Primary Current Fuse, Inrush Limiting
Load Regulation ± 5 % (typical)
Ripple 1 % – 2 % V p-p max. for output voltage at full load
OUTPUT Transient Response 0.5 ms for 50 % load change typical
Leakage Current 0.25 mA max.
Protection Short circuit Protection ▪ Over Voltage Protection ▪ Over Current Protection
Cooling Convection
Efficiency DoE Level VI ▪ Energy Star ▪ ErP Stage 2 ▪ NRCan & GEMS Level VI Certified
OTHERS Holdup Time 10 ms at full load
Dielectric Withstand AC 3000 V Primary – Secondary
MTBF 300,000 calculated hours at 25 °C by telcordia SR-332
Temperature Operating: (0 ~ 40)°C / Storage: (-20 ~ 80)°C
ENVIRONMENT
Humidity Operating:20% ~ 80% RH / Storage: 10% ~ 90% RH non condensing
Output Plug: standard 5.5 x 2.1 x 11mm (spring loaded center) or customer requirement / Cable: 180cm ( 6ft. )
CONNECTION
Input IEC320-C6 / IEC320-C8 / IEC320-C14 available
www.sunny-euro.com
Desktop DRST-160xx-T3 series 150W~160W
GREEN MODE RoHS
Approvals / Marks :
Features:
Wide input range AC 100 V to 240 V / 50 Hz to 60 Hz Single Output to 160W | Regulated Output with Low Ripple Noise
Meets Safety Agency Requirements and Complies EMI/EMS Meets Energy Star Level V & ERP Stage 2 Compliance
Choose from different input connectors: IEC320-C14 or IEC320-C6 Modified and Custom Designs Available
Standard DC output connector: Mini-DIN-plug (4pin) or customer requirement
Specification:
Max.
Voltage DC Loading Tolerance Ripple & Noise Connector
Model Power
[V] [A] [%] [mV] p-p [mm]
[W]
DRST-15012-T3 12 0~12.5 ±5 150 1%~2% x V 4PIN DIN
DRST-16019-T3 19 0~8.40 ±5 160 - -
DRST-16024-T3 24 0~6.60 ±5 160 - -
DRST-16048-T3 48 0~3.30 ±5 160 - -
DRST-16056-T3 56 0~2.90 ±5 160 - -
Voltage (100 ~ 240) VAC
Protection Short circuit Protection ▪ Over Voltage Protection ▪ Over Current Protection
Efficiency DoE Level VI ▪ Energy Star ▪ ErP Stage 2 ▪ NRCan & GEMS Level VI Certified
Output Standard DC plug: Mini-DIN-plug (4pin) UL2464, 18AWG / 16AWG or customer requirement
CONNECTION
Input IEC320-C14 / IEC320-C6 available
www.sunny-euro.com
Desktop DRST-160xx-T3 series 150W~160W
Cable specification:
P1= (+V) | P2= (+V) | P3= (-V) | P4= (-V) | SHIELD=Not Connected
www.sunny-euro.com
Desktop DRST-200xx-T3 series 192W~200W
GREEN MODE RoHS
Approvals / Marks :
Features:
Wide input range AC 100 V to 240 V / 50 Hz to 60 Hz | High frequency design,less power consumption.
Overvoltage, Short Circuit, Over Temperature & Over Current Protection
Choose from different input connectors: IEC320-C14 or IEC320-C6 | Optional Power On / Power Off switch available
Standard DC output connector: Mini-DIN-plug (4pin) or customer requirement
Specification:
Voltage Max.
Loading Tolerance Ripple & Noise Connector
Model DC Power
[A] [%] [mV] p-p [mm]
[V] [W]
DRST-19212-T3 12 0~16.0 ±5 192 3%~5% x V 4PIN DIN
DRST-20024-T3 24 0~8.3 ±5 200 3%~5% x V 4PIN DIN
Voltage (100 ~ 240) VAC
Protection Short circuit Protection ▪ Over Voltage Protection ▪ Over Current Protection
Efficiency DoE Level VI ▪ Energy Star ▪ ErP Stage 2 ▪ NRCan & GEMS Level VI Certified
www.sunny-euro.com
Desktop DRST-200xx-T3 series 192W~200W
Cable specification:
P1= (+V) | P2= (+V) | P3= (-V) | P4= (-V) | SHIELD=Not Connected
www.sunny-euro.com
Laptop STXX-40xx-T2 series 36W~40W
40W
RoHS
Dimension : 86 x 36 x 26 [mm]
Approvals / Marks :
Features:
Single Output.
Wide input voltage (100~240)VAC with IEC 320-C8 Inlet. High Performance.
Overload & Short circuit protection. For I.T.E. use only + RoHS conform.
Specification :
Voltage Max. Connector
Loading Tolerance
Model DC Power UL Approved
[A] [%]
[V] [W] [mm]
STAC-4019-T2 19 0~2.10 ±5 40 2.5x5.5x11-L
Erp V.
STAC-4019-T2 19 0~2.10 ±5 40 1.7x5.5x11-L
OEM Production
Voltage (100 ~ 240)VAC
Inrush Current Maximum inrush current shall be less than 30A at 240Vac input.
Efficiency 70% Min. measured at 240Vac input voltage, maximum load and uninclude the DC cable loss.
SAFETY CE
CE The adapter meet EN60950
G.W.: 11 kg/box
www.sunny-euro.com
Laptop STXX-40xx-T2 series 36W~40W
www.sunny-euro.com
Laptop SKxx-65xx-ST2 series 65W
GREEN MODE RoHS
Approvals / Marks :
Features:
Green Product = High efficiency circuitry that generates little heat : CEC V.
Extra safe design | Built-in EMI filter | Super Slim Model <17mm | Perfect protection function. Available in inlet version:
Simple design philosophy. C8 (T2)
For I.T.E. use only + RoHS conform + Green Power
Specification:
Voltage Line/Road Max.
Loading OVP OCP Ripple & Noise Connector
Model DC regulation Power
[A] [V] [A] [mV] p-p [mm]
[V] [%] [W]
SKAC-6519-ST2 19 0.05~3.42 ±5 - - 65 300 1.7x5.5x11
ErP V.
OEM Production The product is certified for output voltage (16~24)V by 0.1V step for maximum output power 65W
Turn on delay 6000 ms max @ AC low line input@output full load
Hold up time 10ms min @ AC nominal input@ output full load (> half cycle)
OUTPUT Rise time <20ms to rise to within regulation limits for all DC outputs
Efficiency (Normal) >87% (Level V ) @ 240VAC input & Full load
Over-shoot <7% of nominal voltage value
Output LED No
Voltage, operating range (90 ~ 264)VAC
Frequency (47 ~ 63) Hz
Current 1.5A rms @ AC low line input and DC output full load
INPUT Inrush Surge Current (cold start) 80A max @ power supply cold start, ambient temperature 25℃@ 230Vac nominal AC input.
Leakage current ≤0.25 mA Max.
Maximum input power 74.69W
Power consumption 0.5W rms max.
Over Current The power supply will be protection when output power at (110-200)% of all rated dc output
Short-circuit The adapter shall not damage and with auto recovery function by short the DC output to Ground
Over Voltage 28.5V max. The output voltage shall be clamped by internal protection zener
Input protection An adequate internal fuse on dhe AC input line is provide
PROTECTION Insulation restistance Input to Output: 10MΩ(MIN.) at 500VDC
Dielectric Strength (Hi-pot) Primary to Secondary: 3000VAC / 5mA / 60s
Reinforced insulation system Primary-to-Ground and Primary-to-Secondary
Protection class II.
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Cable length 1500mm (5feet) VW-1 80°C 300V 1185 3.5Q 18AWG Black (PAHS, REACH) round cable or depends on customer requirements
OTHERS Cooling method By natural air, the maximum room ambient temperature for externap PSU is 40°C (mentioned in clause 1.4.12 of IEC 60950-1)
Housing matherial PPHOX (UL94V-1 SE-1) Black
Temperature coefficient: < ±0.5% / °C
Temperature Operating: (0 ~ 40)°C / Storage: (-20 ~ 80)°C
ENVIRONMENT
Humidity Operating: 10% ~ 90% RH / Storage: 10% ~ 90% RH non condensing
SAFETY CE | TUV/GS | cULus | FCC
EMC UL 60950 | TUV/VDE-EN60950 | CE | EN 60950-1
WEIGHT 1pc N.W.: 242g | G.W.: 265g
0.51(L) x 0.36(W) x 0.19(H) [m]
PACKING Box 45 pcs / 1box
G.W.: 12.8kg
www.sunny-euro.com
Laptop SKxx-65xx-ST2 series 65W
Cable specification:
www.sunny-euro.com
LED Driver SYL1460-Wxx series 24W
GREEN MODE RoHS
Approvals / Marks :
Features:
Wall-mount LED Driver with Exchangeable AC Plugs. For LED applications use only
Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz. RoHS conform
Customer can choose one or more certified plugs Wxx*(W2E, W2, W3U, W2A, W2C).
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement.
Specification:
Voltage Line/Road Over Over Max. Ripple / Connector
Loading
Model DC regulation Current Voltage Power Noise UL approved
[A]
[V] [%] [A] [V] [W] [mV] p-p [mm]
SYL1460-2412-Wxx* 12 0.01~2.00 5 2.05 ~ 3.5 < 20 24 250 2.1x5.5x11
ErP V. SYL1460-2415-Wxx* 15 0.01~1.60 5 1.65 ~ 3.0 < 25 24 250 2.1x5.5x11
SYL1460-2424-Wxx* 24 0.01~1.00 5 1.05 ~ 2.0 < 40 24 300 2.1x5.5x11
*Wxx Possible to order with Wxx =W2E - Europe | W2 - USA,Canada | W3U - UK | W2A - Australia | W2C - China
Voltage (90 ~ 264) VAC
Frequency (47 ~ 63) Hz
INPUT Current 0.5A rms@ AC low line input and DC output full load
Inrush Current (cold start) 60Amax. @ LED Driver cold start, ambient temperature 25℃ @230Vac nominal AC input.
Leakage current 0.25 mA max.
Over Current The LED Driver will self-protect any output to ground, And auto recovery when abnormal circuit faults remove.
PROTECTION Over Voltage The LED Driver will not be auto recovered when faults remove
Short Circuit Is defined as any output impedance of less than 0.1Ω. The LED Driver will be auto recovered when short circuit faults remove.
Efficiency (typical) ≧82.1%@ full load according upon spec
Power factor 0.9 min At AC nominal input @ output full load
Standby Power 0.3W rms max. At AC nominal input @ output min load
OTHERS
Cooling Free air convection
M.T.B.F. 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
HI-POT IEC 320 2pin primary to secondary 3750Vac 10mA 1min
Temperature Operating: (0 ~ 40)°C / Storage: (-20 ~ 85)°C
ENVIRONMENT
Humidity Operating: 8% ~ 90% RH non condensing / Storage: 5% ~ 95% RH non condensing
Input Plugs: EU, UK, US, AUS, China (exchangeable)
CONNECTION
Output Plug standard center ‘+’ or customer requirement // Cable length 1,8m
www.sunny-euro.com
LED Driver SYL1460-Wxx series 24W
Cable specification:
www.sunny-euro.com
Car adapter SYD1151-CUV series 13W
RoHS
Approvals / Marks :
Truck 24 V Car 12 V
Features:
Car adapter for notebook can be used in cars and trucks (12V or 24V cigarette plug).
Output current & output voltage protection.
Input range (10 ~ 30)VDC. Power ON – Green LED.
For I.T.E. use only + RoHS conform. | For iPhone / iPad and other
Specification:
Voltage min. max. Max. Ripple
Efficiency OCP Connector
Model DC Load Load Power & Noise
[%] [A] [mm]
[V] [A] [A] [W] [mV]p-p max.
ErP V.
SYD1151-1305-CUV 5.0 0 2.5 75 2.7-4.0 12.5 <200 USB inlet
(*) Depends on customer request if USB inlet or DC cable with DC UL approved connector
Input Current 1.8 A rms max At low line input and DC output full load
Input Fuse 3.15A The power supply shall be protected against power line surges and any abnormal condition.
The power supply shall be protected from damage of accidentally when the I/P voltage is between 11Vdc and 32Vdc.the O/P short
Short Circuit
protection could be protected forever .input power do not Exceed 5W when output is shorted.
PROTECTION
Over Current Removal of an output overload conditions shall permit automatic recovery of the output voltage.
SAFETY CE
EMC 2014/30/EU
CE 2014/35/EU
LVD
EN 60950-1:2006+A11+A1+A12+A2
WEIGHT 1pc N.W.: 40g / pc | G.W.: 42g/pc
www.sunny-euro.com
Car adapter SYD1151-CUV series 13W
www.sunny-euro.com
USB SYD1181 serie 36W
RoHS
Approvals / Marks :
Features:
For any combination of iOS devices, tablets, smartphones and all other USB devices and accessories.
Powered by switching power supplies SYS1548 series
Input range (10 ~ 30)VDC.
RoHS conform.
Specification:
max. Max. Ripple
Voltage DC Efficiency OCP
Model Load Power & Noise Connector
[V] [%] [A]
[A] [W] [mV]p-p max.
USB Port1 +5V
ErP V. USB Port2 +5V
USB Port3 +5V
SYD1181-3605 7.2 80 2.5-3.0 36 <150 6 USB ports
USB Port4 +5V
USB Port5 +5V
USB Port6 +5V
Input Current 5A rms max At low line input and DC output full load
INPUT
Load regulation ±5%
Turn on delay 2000ms max At low line input @ output full load
Input Fuse 6.3A The power supply shall be protected against power line surges and any abnormal condition.
The power supply shall be protected from damage of accidentally when the I/P voltage is between 12Vdc and 24Vdc.the O/P short
Short Circuit
protection could be protected forever . Input power do not Exceed 5W when output is shorted.
PROTECTION
Over Current Removal of an output overload conditions shall permit automatic recovery of the output voltage.
SAFETY CE
WEIGHT 1pc N.W.: 85g / pc | G.W.: 100g/pc
G.W.: 12 kg / box
www.sunny-euro.com
USB SYD1181 serie 36W
Mechanical specification:
www.sunny-euro.com
USB SYD1182 serie 48W
RoHS
Approvals / Marks :
Features:
For any combination of iOS devices, tablets, smartphones and all other USB devices and accessories.
Powered by switching power supplies SYS1548 series
Input range (10 ~ 30)VDC.
RoHS conform.
Specification:
max. Max. Ripple
Voltage DC Efficiency OCP
Model Load Power & Noise Connector
[V] [%] [A]
[A] [W] [mV]p-p max.
USB Port1 +5V
USB Port2 +5V
ErP V. USB Port3 +5V
USB Port4 +5V
SYD1182-4805 9.6 80 2.5-3.0 48 <150 8 USB ports
USB Port5 +5V
USB Port6 +5V
USB Port7 +5V
USB Port8 +5V
Voltage (10 ~ 30)VDC
Input Current 5A rms max At low line input and DC output full load
INPUT
Load regulation ±5%
Turn on delay 2000ms max At low line input @ output full load
Input Fuse 7.0A The power supply shall be protected against power line surges and any abnormal condition.
The power supply shall be protected from damage of accidentally when the I/P voltage is between 12Vdc and 24Vdc.the O/P short
Short Circuit
PROTECTION protection could be protected forever. Input power do not Exceed 5W when output is shorted.
Over Current Removal of an output overload conditions shall permit automatic recovery of the output voltage.
SAFETY CE
WEIGHT 1pc N.W.: 120g / pc | G.W.: 140g/pc
www.sunny-euro.com
USB SYD1182 serie 48W
Mechanical specification:
www.sunny-euro.com
Power cable IEC320-C5 series
IEC320-C5 (EU)
Country of Origin : China
Operating Temperature : 0 ÷ 40 [°C]
Length/cord : 1.8m / 3x0.75mm2
Approvals : VDE
Application For Class I. Appliances
1pc N.W.: 174g / pc
0.55 x 0.36 x 0.20 [m]
WEIGHT / PACKING
Box 100pcs / 1box
G.W.: 19.0kg / box
IEC320-C5 (UK)
Country of Origin : China
Operating Temperature : 0 ÷ 40[°C]
Length/cord : 1.8m / 3x0.75mm2
Approvals : ASTA
Application For Class I. Appliances
The British Standards 1363 plug (13A Plug)
UK Plug IS 401 and IS 411 (Ireland), MS 589 (Malaysia) and
SS 145 (Singapore), and SASO 2203 (Saudi Arabia).
Fuse 3A / 250V
IEC320-C5 (UL)
Country of Origin : China
Operating Temperature : 0 ÷ 40 [°C]
Length/cord : 1.8m / 3x0.75mm2
Approvals : UL
Application For Class I. Appliances
American standard NEMA 5-15
UL Plug
Canadian standard CS22.2, n°42
1pc N.W.: 72g / pc
0.56 x 0.36 x 0.20 [m]
WEIGHT / PACKING
Box 100pcs / 1box
G.W.: 16kg / box
www.sunny-euro.com
Power cable IEC320-C7series
IEC320-C7 (EU)
Country of Origin : China
Operating Temperature : 0 ÷ 40 [°C]
Length/cord : 1.8m / 2x0.75mm2
Approvals : VDE
Application For Class II. Appliances
1pc N.W.: 84g / pc
0.56 x 0.36 x 0.20 [m]
WEIGHT / PACKING
Box 200pcs / 1box
G.W.: 17.7 kg / box
IEC320-C7 (UK)
Country of Origin : China
Operating Temperature : 0 ÷ 40 [°C]
Length/cord : 1.8m / 2x0.75mm2
Approvals : ASTA
Application For Class II. Appliances
The British Standards 1363 plug (13A Plug)
UL Plug IS 401 and IS 411 (Ireland), MS 589 (Malaysia) and SS 145
(Singapore), and SASO 2203 (Saudi Arabia).
Fuse 5A / 250V
1pc N.W.: 120g / pc
0.56 x 0.36 x 0.20 [m]
WEIGHT / PACKING
Box 100pcs / 1box
G.W.: 14 kg / box
IEC320-C7 (UL)
Country of Origin : China
Operating Temperature : 0 ÷ 40 [°C]
Length/cord : 1.8m / 2x0.75mm2
Approvals : UL
Application For Class II. Appliances
UL Plug American standard NEMA 1-15
1pc N.W.: 72g / pc
0.56 x 0.36 x 0.20 [m]
WEIGHT / PACKING
Box 200pcs / 1box
G.W.: 15.5 kg / box
IEC320-C7 (Aus)
Country of Origin : China
Operating Temperature : 0 ÷ 40[°C]
www.sunny-euro.com
Power cable IEC320-C13 series
IEC320-C13 (Aus)
Country of Origin : China
Approvals : SAA, VDE, KEMA-KEUR, CEBEC, DEMKO, Intertek, Nemko, NCS/FI, SEV,
ÖVE, IMQ, NF
IEC320-C13 (Brazil)
Country of Origin : China
Operating Temperature : 0 ÷ 40 [°C]
Approvals : TUV, VDE, KEMA-KEUR, CEBEC, DEMKO, Intertek, Nemko, ENEC/FI, SEV,
ÖVE
IEC320-C13 (Swiss)
Country of Origin : China
Operating Temperature : 0 ÷ 40 [°C]
Length/cord : 1.8m / 3x0.75mm2
Approvals : SEV
www.sunny-euro.com
Power cable IEC320-C13 series
IEC320-C13 (EU)
Country of Origin : China
Operating Temperature : 0 ÷ 40[°C]
Length/cord : 1.8m / 3x0.75mm2
Approvals : VDE, KEMA-KEUR, CEBEC, DEMKO, Intertek, Nemko, NCS/FI, ÖVE, IMQ,
NF, SEV
IEC320-C13 (UK)
Country of Origin : China
Operating Temperature : 0 ÷ 40[°C]
Length/cord : 1.8m / 3x0.75mm2
Approvals : ASTA
IEC320-C13 (UL)
Country of Origin : China
Approvals : UL
www.sunny-euro.com
Power cable IEC320-C13 series
IEC320-C13 (C)
Country of Origin : China
Operating Temperature : 0 ÷ 40[°C]
Length/cord : 1.8m / 3x0.75mm2
Approvals : CCC
Application For Class I. Appliances
1pc N.W.: 182g / pc
0.55 x 0.36 x 0.20 [m]
WEIGHT / PACKING
Box 90pcs / 1box
G.W.: 18.2 kg / box
IEC320-C13 (AG)
Country of Origin : China
Operating Temperature : 0 ÷ 40[°C]
Length/cord : 1.8m / 3x0.75mm2
Approvals : IRAM, VDE, CEBEC, KEMA-KEUR, DEMKO, Intertek, Nemko, NCS/FI, ÖVE,
IMQ, NF, SEV
Application For Class I. Appliances
1pc N.W.: 179g / pc
0.55 x 0.36 x 0.20 [m]
WEIGHT / PACKING
Box 90pcs / 1box
G.W.: 18.0 kg / box
IEC320-C13 (Italy)
Country of Origin : China
Operating Temperature : 0 ÷ 40[°C]
Length/cord : 1.8m / 3x0.75mm2
Approvals : VDE, KEMA-KEUR, CEBEC, DEMKO, Intertek, Nemko, ENEC/FI, SEV,ÖVE,
IMQ, NF
Application For Class I. Appliances
1pc N.W.: 158g / pc
0.36 x 0.20 x 0.55 [m]
WEIGHT / PACKING
Box 100pcs / 1box
G.W.: 16.9 kg / box
www.sunny-euro.com
Extension cable Plug
50pcs / 1bunch
PACKING Bunch
G.W.: 0.3 kg / bunch
20pcs / 1bunch
PACKING Bunch
G.W.: 0.32 kg / bunch
10pcs / 1bunch
PACKING Bunch
G.W.: 0.27 kg / bunch
5pcs / 1bunch
PACKING Box
G.W.: 0.41 kg / bunch
www.sunny-euro.com
Extension cable Plug
5pcs / 1bunch
PACKING Box
G.W.: 0.53 kg / bunch
www.sunny-euro.com
Extension cable Jack
DC Connector 2.1x5.5x11
2.5x5.5x11
50pcs / 1bunch
PACKING Bunch
G.W.: 0.5 kg / bunch
DC Connector : 2.1x5.5x11
200pcs / 1bunch
PACKING Bunch
G.W.: 2.6kg / bunch
DC Connector : 2.1x5.5x11
100pcs / 1bunch
PACKING Bunch
G.W.: 1.9 kg / bunch
DC Connector : 2.1x5.5x11
5pcs / 1bunch
PACKING Bunch
G.W.: 0.54 kg / bunch
www.sunny-euro.com
Extension cable Jack to Plug
DC Connector types: Plug 2.1x5.5x11 with center springs & Jack 2.1x5.5x11
10 [pcs]
PACKING Bunch
G.W.: 0.490 [kg]
DC Connector types: Plug 2.1x5.5x11 with center springs & Jack 2.1x5.5x11
5 [pcs]
PACKING Bunch
G.W.: 0.560 [kg]
www.sunny-euro.com
Extension cable Plug to Plug
150 [pcs]
PACKING Bunch
G.W.: 3.150 [kg]
20 [pcs]
PACKING Bunch
G.W.: 0.680 [kg]
www.sunny-euro.com
Extension cable SWITCH
www.sunny-euro.com
Extension cable USB
www.sunny-euro.com
Extension cable USB
www.sunny-euro.com
Cable Splitter
www.sunny-euro.com
Cable Splitter CHAIN
100pcs
PACKING Plastic bag
G.W.: 5.4kg
www.sunny-euro.com
Reduction connectors
www.sunny-euro.com