DT HP102

The DT-HP102 geophone element has a natural frequency of 10 Hz with low distortion below 0.1% and a 3-year limited warranty. It is suitable for various 2D and 3D seismic applications on land and in shallow water. Key specifications include a frequency of 10 Hz, distortion below 0.1%, damping of 0.7, and a sensitivity of 27.5 V/m/s without a shunt resistor.

Uploaded by

kankukejardikau1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views1 page

DT HP102

The DT-HP102 geophone element has a natural frequency of 10 Hz with low distortion below 0.1% and a 3-year limited warranty. It is suitable for various 2D and 3D seismic applications on land and in shallow water. Key specifications include a frequency of 10 Hz, distortion below 0.1%, damping of 0.7, and a sensitivity of 27.5 V/m/s without a shunt resistor.

Uploaded by

kankukejardikau1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DT-HP102 (P/N:611000100)

High Precision, Low Distortion Geophone Element


Low distortion and close tolerance geophone
High quality, reliable and cost effective
3 years limited warranty
2-D and 3-D seismic application
Suitable for land, transition zone, marsh and
shallow water environments with different cases

Specifications (all parameters are specified at + 25° C)


Frequency Natural Frequency (Fn) 10 Hz
Tolerance ± 2.5%
Max. Tilt Angle for Specified (Fn) 20°
Typical Spurious Frequency >250 Hz

Distortion Distortion with 0.7 in/s p.p. Coil to Case Velocity < 0.10%
Distortion Measurement Frequency 12 Hz
Max. Tilt Angle for Distortion Specification 10°
Typical Distortion (string of 12 geophones in series
≤0.03%
damped 0.70, measured at 12 Hz)

Damping Typical Open Circuit Damping 0.316


Damping Calibration-Shunt Resistance 1,000 ohm
Damping with Calibration-Shunt 0.7
Tolerance with Calibration-Shunt ± 2.5%

Coil Resistance Standard 395 ohm


Tolerance ± 2.5%

Sensitivity Sensitivity without Shunt Resistor 27.5 V/m/s (0.698 V/in/s)


Sensitivity with 1000 ohm Shunt Resistor 19.7 V/m/s (0.500 V/in/s)
Tolerance ± 2.5%

Physical Moving Mass 11.2 g (0.395 oz)


Characteristics 1.52 mm (0.060 in)
Maximum Coil Excursion p.p.
Diameter 25.4 mm (1 in)
Height 33.0 mm (1.30 in)
Weight 86 g (3.03 oz)
Operating Temperature Range -40° C to +100° C

Warranty excludes damage caused by high voltage and physical damage to the element case.