PRODUCT DATA SHEET
Sikafloor®-2530 W
2-PART WATER BASED EPOXY COATING
DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sikafloor®-2530 W is a two part, water dispersed, col- ▪ Good chemical and mechanical resistance
oured, epoxy resin based coating for flooring applica- ▪ Water vapour permeable
tions. ▪ Water dilutable
▪ Odourless
USES ▪ Easy application
Sikafloor®-2530 W may only be used by experienced
professionals.
Sikafloor®-2530 W is used as:
▪ Coloured epoxy coating for concrete, cement
screeds, broadcast systems and epoxy mortars
▪ Can be subjected to normal up to medium heavy
mechanical and chemical loading
▪ For production areas, warehouses, car park decks,
garages, etc.
PRODUCT INFORMATION
Composition Epoxy, waterborne
Packaging Part A 4.2 kg and 12.6 kg containers
Part B 1.8 kg and 5.4 kg containers
Part A+B 6.0 kg and 18 kg ready to mix units
Appearance / Colour Resin - part A: coloured, liquid
Hardener - part B transparent, liquid
Available in various colour shades.
With light colour shades (e.g. yellow or orange) it may be necessary to ap-
ply several coats of Sikafloor®-2530 W to achieve full opacity (hiding
power).
Under direct sun radiation there may be some discolouration and colour
deviation, this has no influence on the function and performance of the
coating.
Shelf Life 12 months from date of production
Storage Conditions The product must be stored in original, unopened and undamaged sealed
packaging in dry conditions at temperatures between +5 °C and +30 °C.
Product Data Sheet
Sikafloor®-2530 W
May 2018, Version 03.01
020811010020000001
1/4
Density Part A ~1.28 kg/l (DIN EN ISO 2811-1)
Part B ~1.09 kg/l
Mixed resin ~1.22 kg/l
All Density values at +23 °C.
Solid content by weight ~55 %
Solid content by volume ~43 %
TECHNICAL INFORMATION
Chemical Resistance Resistant to many chemicals. Contact Sika technical service for specific in-
formation.
Temperature Resistance Exposure* Dry heat
Permanent +50 °C
Short-term max. 7 d +80 °C
Short-term max. 8 h +100 °C
Short-term moist/wet heat* up to +80 °C where exposure is only occasion-
al (steam cleaning etc.).
*No simultaneous chemical and mechanical exposure and only in combination with Sikafloor® systems as a
broadcast system with approx. 3–4 mm thickness.
APPLICATION INFORMATION
Mixing Ratio Part A : part B = 70: 30 (by weight)
Consumption ~0.2–0.3 kg/m² applied as a roller coating
These figures are theoretical and do not allow for any additional material
due to surface porosity, surface profile, variations in level or wastage etc.
For detailed info, please refer to the System data sheet Sikafloor® Multidur
WS-11.
Ambient Air Temperature +10 °C min. / +30 °C max.
Relative Air Humidity 80 % r.h. max.
Dew Point Beware of condensation!
The substrate and uncured floor must be at least 3 °C above dew point to
reduce the risk of condensation or blooming on the floor finish.
Note: Low temperatures and high humidity conditions increase the probab-
ility of blooming.
Substrate Temperature +10 °C min. / +30 °C max.
Substrate Moisture Content < 6 % pbw moisture content.
Test method: Sika®-Tramex meter, CM-measurement or Oven-dry-method.
No rising moisture according to ASTM (Polyethylene-sheet).
Pot Life Temperature Time
+10 °C ~150 minutes
+20 °C ~120 minutes
+30 °C ~60 minutes
Curing Time Before overcoating Sikafloor®-2530 W allow:
Substrate temperature Minimum Maximum
+10 °C 48 hours 7 days
+20 °C 20 hours 5 days
+30 °C 10 hours 3 days
Times are approximate and will be affected by changing ambient condi-
tions particularly temperature and relative humidity.
APPLICATION INSTRUCTIONS ▪ The concrete substrate must be sound and of suffi-
cient compressive strength (minimum 25 N/mm²)
SUBSTRATE QUALITY / PRE-TREATMENT with a minimum pull off strength of 1.5 N/mm².
Product Data Sheet
Sikafloor®-2530 W
May 2018, Version 03.01
020811010020000001
2/4
▪ The substrate must be clean, dry and free of all con- FURTHER DOCUMENTS
taminants such as dirt, oil, grease, coatings and sur-
face treatments, etc. Substrate quality & Preparation
▪ Concrete substrates must be prepared mechanically Please refer to Sika Method Statement: “EVALUATION
using abrasive blast cleaning or scarifying equipment AND PREPARATION OF SURFACES FOR FLOORING SYS-
to remove cement laitance and achieve an open tex- TEMS”.
tured surface. Application instructions
▪ Weak concrete must be removed and surface de- Please refer to Sika Method Statement: “MIXING & AP-
fects such as blow holes and voids must be fully ex- PLICATION OF FLOORING SYSTEMS”.
posed. Maintenance
▪ Repairs to the substrate, filling of blowholes/voids Please refer to “Sikafloor®- CLEANING REGIME”.
and surface levelling must be carried out using ap-
propriate products from the Sikafloor®, Sikadur® and IMPORTANT CONSIDERATIONS
Sikagard® range of materials.
▪ All dust, loose and friable material must be com- ▪ Do not apply Sikafloor®-2530 W on substrates with
pletely removed from all surfaces before application rising moisture.
of the product, preferably by brush or vacuum. ▪ Freshly applied Sikafloor®-2530 W should be protec-
ted from damp, condensation and water for at least
MIXING 24 hours.
Prior to mixing, stir part A mechanically. When all of ▪ Always ensure adequate fresh air ventilation when
part B has been added to part A, mix continuously for using Sikafloor®-2530 W in confined spaces to avoid
2 minutes until a uniform mix has been achieved. curing problems.
To ensure thorough mixing pour materials into anoth- ▪ The “gloss” of the finish can vary with temperature,
er container and mix again to achieve a consistent mix. humidity and the absorbency of the substrate
Over mixing must be avoided to minimise air entrain- ▪ The incorrect assessment and treatment of cracks
ment. may lead to a reduced service life and reflective
Mixing Tools: cracking.
Sikafloor®-2530 W must be thoroughly mixed using a ▪ For exact colour matching, ensure the Sikafloor®-
low speed electric stirrer (300–400 rpm) or other suit- 2530 W in each area is applied from the same con-
able equipment. trol batch numbers.
▪ Under certain conditions, underfloor heating or high
APPLICATION ambient temperatures combined with high point
loading, may lead to imprints in the resin.
Prior to application, confirm substrate moisture con- ▪ If heating is required do not use gas, oil, paraffin or
tent, relative air humidity and dew point. other fossil fuel heaters, these produce large quantit-
If > 6 % pbw moisture content, Sikafloor® EpoCem® ies of both CO2 and H2O water vapour, which may
may be applied as a T.M.B. (temporary moisture barri- adversely affect the finish. For heating use only elec-
er) system. tric powered warm air blower systems.
Primer:
Make sure that a continuous, pore free coat covers the BASIS OF PRODUCT DATA
substrate. If necessary, apply two priming coats. When
used as a primer always apply by brush. All technical data stated in this Product Data Sheet are
Seal coat: based on laboratory tests. Actual measured data may
Sikafloor®-2530 W is spread evenly by means of a vary due to circumstances beyond our control.
short pile roller.
A seamless finish can be achieved if a “wet” edge is LOCAL RESTRICTIONS
maintained during application.
Uneven application of the material and resulting dif- Please note that as a result of specific local regula-
ferences in the coating layer thicknesses may cause tions the performance of this product may vary from
differences in “gloss” of the surface. country to country. Please consult the local Product
Data Sheet for the exact description of the application
CLEANING OF TOOLS fields.
Clean all tools and application equipment with water
immediately after use. Hardened and/or cured materi- ECOLOGY, HEALTH AND SAFETY
al can only be removed mechanically. For information and advice on the safe handling, stor-
age and disposal of chemical products, users shall refer
MAINTENANCE to the most recent Safety Data Sheet (SDS) containing
physical, ecological, toxicological and other safety-re-
To maintain the appearance of the floor after applica- lated data.
tion, Sikafloor®-2530 W must have all spillages re-
moved immediately and must be regularly cleaned us-
ing rotary brush, mechanical scrubbers, scrubber dry- LEGAL NOTES
er, high pressure washer, wash and vacuum tech- The information, and, in particular, the recommenda-
niques etc. using suitable detergents and waxes. tions relating to the application and end-use of Sika
Product Data Sheet
Sikafloor®-2530 W
May 2018, Version 03.01
020811010020000001
3/4
products, are given in good faith based on Sika's cur-
rent knowledge and experience of the products when
properly stored, handled and applied under normal
conditions in accordance with Sika’s recommenda-
tions. In practice, the differences in materials, sub-
strates and actual site conditions are such that no war-
ranty in respect of merchantability or of fitness for a
particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
from this information, or from any written recom-
mendations, or from any other advice offered. The
user of the product must test the product’s suitability
for the intended application and purpose. Sika re-
serves the right to change the properties of its
products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data
Sheet for the product concerned, copies of which will
be supplied on request.
Sika Kimia Sdn. Bhd.
Lot 689, Nilai Industrial Estate, 71800 Nilai
Negeri Sembilan D.K., Malaysia
Phone: +606-7991762
Fax: +606-7991980
e-mail: info@my.sika.com
Website: www.sika.com.my
Sikafloor-2530W-en-MY-(05-2018)-3-1.pdf
Product Data Sheet
Sikafloor®-2530 W
May 2018, Version 03.01
020811010020000001
4/4