1. The structural drawings should be read together with relevant architectural, electrical, mechanical, and plumbing drawings. 2. A minimum of 5 cm of plain concrete should be provided under any reinforced concrete in contact with soil. 3. Mix designs should be submitted along with relevant test results like sieve analysis, slump test, and strength test for approval before any concrete work begins.

Uploaded by

Jaspergroup 15
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views1 page

ST 01

1. The structural drawings should be read together with relevant architectural, electrical, mechanical, and plumbing drawings. 2. A minimum of 5 cm of plain concrete should be provided under any reinforced concrete in contact with soil. 3. Mix designs should be submitted along with relevant test results like sieve analysis, slump test, and strength test for approval before any concrete work begins.

Uploaded by

Jaspergroup 15
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTES

A - GENERAL
A B B` C 1 - ALL STRUCTURAL DROWINGS SHOULD BE READ IN CONJUNCTION
WITH RELEVANT ARCHITECTURAL,ELEC,MEP...ETC DRAWINGS.
2 - MINIMUM 5 CM OF PLAIN CONCRETE SHOLD BE PROVIDED UNDER

4200 700 2400 ANY R.C IN CONTACT WITH SOIL

A B B` C 3 - MIX DISIGN SHOULD BE SUBMITED ALL RELEVANT TEST LIKE


SIEVE ANALYSIS SLUMP TEST AND STRENGTH TESTFOR APPROVED
BEFOR COMMENCING ANY CONCRETE WORK
4 - APPROVE TENSILE TESTES SHOULD BE DONE ON STEEL SAMPLE TEKEN

4200 700 2400 FROM EVERY MATERIALS TO BE USED SHOULD BE SUB MITTED AND THIS
APPLY FOR ANY NEW DELIVERY
5 - POLYTHENE SHEETS G-500 SHOULD BE PROVIDED UNDER SUB

2300 3700 FLOOR SLABS


B - COVER OF RENFORCIMENTS
2000 NORMAN COVER OF ALL RENFORCIMENT IS AS FOLLOWS
1850

-SLAB AND BEAMS : 25 MM


-INTERIOR COLUMNS : 25 MM
GFB-8 -EXTERIOR COLUMNS : 25 MM

GFB-10
1200 -FOOTINGS - RETAINING WALL AND UNDER GROUND WATER TANK : 50 MM
C - SOIL INVESTIGATION

1850

1700
Ø8/200 mesh
+0.30 - A SOIL INVESTIGATION SHALL BE CARRIED OUT AND THE STUCTURAL

450 450 C-2 250


DESIGN OF FOOTING
- THE NO OF BARE HOLE SHALL BE DETERMIND BY THE FOUNDATION
ENGINER
2000

2300

1200
3
300

300
+0.45

350
D - MATERIAL
1 - CEMENT
450 450 250 - APPROVED PRODUCT OF PORTLAND CEMENT SHOULD BE USED FOR

C-1 C-1 3
SUPER-STRUCTURE

300

300

350
2 - AGGREGATES
-ONLY WESHED CRUSHED AGGREGATE (APPROVED BY THE CONCULTANT
GFB-7 OR THE SUPERVISE ENGINER) SHULD BE USED

1200
3 - WATER
-PURE AND FREE FROM SALT WATER SHOULD BE USE
4 - CONCREATE
- CHARACTERSTIC STRENGTH OF CONCRETE AFTER 28 DAYS SHOULD NOT
BE LESS THAN 30 N/MM2 OR 30 MPA

1025 - WATER CEMENT RATIO SHOULD BE NOT EXCEED 0.45 AT ANY STAGE
5 - STEEL
SRIF-1

300
- ALL STEEL SHOULD BE HIGH YIELD STRESS NOT LESS THAN 400 N/MM2
4100

Ø8/200 mesh 6 - BACK FILL

GFB-12
- BACK FILL MATERIALS MUST BE WELL GRANULAR, GRADED SELECTED
SPREAD ON LAYERS (EACH LAYERS NOT EXCEED 250MM) CARRIDE OUT

4100
IN ACCORDING TO SPECIFICATION

300
2600 E - REINFORCEMENT
- REINFORCEMENT LABS (OVER LAP) LENGTHS SHOULD BE NOT LESS
THAN 40XDIA OF REINFORCEMENT BAR
2100 Ø8/200 mesh F CONSTRUCT MASONERY WALL ON THE PERIPHERY ON THE BUILDING

450
1200

300
C-4 C-5 C-3 +0.45
2100

2600

250
300
300

350
GFB-7
400 600
2

250
300
300
400 600 350
Ø8/200 mesh

GFB-13
450

1850

GFB-11
1200

GFB-9
2600
SRIF-2 GFB-6
1'

300

300
Ø8/200 mesh
5900

Ø8/200 mesh
4050

+0.45
2100
1600
±0.000

C-6 C-7 C-2


2100

1600

1 GFB-5
300
2600

GFB-2
250

250

250
1

300
250

250
400 500 350
400 500 350
800 200
GFB-4

±0.000
2150

1200

1600

GFB-3
2150

GFB-3
NO.
OWNER

2600 ..........................
GFB-1

200
SRIF-3 200 PROJECT
..........................
LOCATION Title Deed Number
SEBETA

Footing Rienforcement Layout TITLE


STRUCTURAL DESIGN DETAIL DRAWINGS

Scale 1:50 Ground Foor Beam & Slab Rienforcement Layout DESIGNER:-
ABDULWAHID K. PE/21086
DRAWING NO.

(T= 100 mm) @ Level +0.00 & +0.45, Scale 1:50 CAD BY
ABDULWAHID K.
ST
01
09