0% found this document useful (0 votes)
146 views1 page

TDS-CMP 757

The document provides information on the 757 Hexagon Head Stopper Plug, which is used to blank unused cable entries in explosive atmospheres. It can be used temporarily or permanently. It is available in different materials like brass, aluminum, and stainless steel. It has approvals from various global certification bodies for use in explosive gas atmospheres. It provides details on its technical classification, global product certification, compliance standards, and how to order the product with different thread and material options.

Uploaded by

mohd darus
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
146 views1 page

TDS-CMP 757

The document provides information on the 757 Hexagon Head Stopper Plug, which is used to blank unused cable entries in explosive atmospheres. It can be used temporarily or permanently. It is available in different materials like brass, aluminum, and stainless steel. It has approvals from various global certification bodies for use in explosive gas atmospheres. It provides details on its technical classification, global product certification, compliance standards, and how to order the product with different thread and material options.

Uploaded by

mohd darus
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

757

757
757 HEXAGON HEAD STOPPER PLUG,
GLOBALLY APPROVED, EXPLOSIVE
ATMOSPHERE CABLE / CONDUIT
ACCESSORY

 rovides means of blanking unused cable entries


P
Temporary or permanent
G eneral purpose / industrial version available
Equipment interface ‘O’ ring seal available
-60˚C to 200˚C (metallic versions), -20˚C to +60˚C
(nylon Ex e)
Globally marked, IECEx, ATEX, cCSAus & UL (metallic +200˚C
versions only)
-60˚C

TECHNICAL CLASSIFICATION GLOBAL PRODUCT CERTIFICATION


DESIGN SPECIFICATION BS 6121:Part 1:1989 IECEx CML 18.0177X,
ATEX CERTIFICATE CML18ATEX1320X IECEx CERTIFICATE
IECEx SIM 15.0002X
ENCLOSURE PROTECTION IK10 to IEC 62262 (20 joules) Brass & Stainless Steel Only
^ II 2G 1D Ex db IIC Gb,
INGRESS PROTECTION RATING** IP66, IP67 & IP68*** Ex eb IIC Gb, Ex ta IIIC Da Ex db I Mb, Ex eb I Mb; Ex db
^ I M2 Ex db I Mb, IIC Gb, Ex eb IIC Gb,
AVAILABLE MATERIALS Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel, Nylon CODE OF PROTECTION Ex eb I Mb CODE OF PROTECTION Ex ta IIIC Da (Ex eb IIC Gb,
CONTINUOUS OPERATING (II 2G 1D Ex eb IIC Gb, Ex ta IIIC Da only on Nylon
-60°C to +200°C (Metallic), -20°C to +60°C (Nylon) Ex ta IIIC Da only on Nylon version)
TEMPERATURE
version)
* Dimensions shown for metric threads alternative thread dimensions may vary ** When CMP
installation accessories are used. Refer to www.cmp-products.com for further information. *** COMPLIANCE STANDARDS EN 60079-0,1,7, 31 COMPLIANCE STANDARDS IEC 60079-0,1, 7, 31
IP68 tested to a minimum depth of 30 metres for 12 hours, alternative depths / durations can be
provided upon request. 1055233 E214221
cCSAus CERTIFICATE UL CERTIFICATE
(Metallic versions only) (Metallic versions only)
Ex e II, Class I, Zone 1,
Class I Div 1 & 2, Groups
AEx e II; IP66, 67, 68;
CODE OF PROTECTION CODE OF PROTECTION A,B,C,D; Class II Groups
Enclosure Type 4X; Class II
E,F,G; Class III
Groups E, F and G; Class III
757 Series Stopper Plug 757 Series Stopper Plug C22.2 No. 0, 0.5, 30,94,
with optional ‘O’ ring
CAN/CSA 60079-0, 1, 7,
COMPLIANCE STANDARDS COMPLIANCE STANDARDS UL 1203
B B UL50 Edition 11, UL1203
Edition 4, UL 60079-0, 1, 7
EAC CERTIFICATE TC RU C-GB.AA87.B.00487 UkrSEPRO CЦ 19.0372X
RETIE APPROVAL NUMBER 03866 CCOE / PESO (INDIA) CERTIFICATE P444949
NEPSI CERTIFICATE GYJ18.1255X INMETRO APPROVAL TÜV 12.1333X
KCs KOSHA CERTIFICATE 14-GA4BO-0255X ECAS CERTIFICATE 20-02-05266
A A
MARINE APPROVALS LRS: 01/00173, DNV: TAE000000Y, ABS: 17-LD1619350-PDA, BV: 43180 A1 BV

HOW TO ORDER
e.g. 757 - D - M - 3 - 1
= Dual certified Ex d & Ex e - M25 - Aluminium
Other thread variations are available on request. For further information on ordering please refer to page 163.

THREAD CONVERSIONS & ACCESSORIES


When ordered with the integral ‘O’ ring seal the across flats dimension shown may increase to accommodate the ‘O’ ring.

ALLEN KEY METALLIC NON-METALLIC PRODUCT SELECTION TABLE*


DESCRIPTION
RECESS Ex 'd' Ex 'e' INDUSTRIAL Ex 'e' INDUSTRIAL MINIMUM THREAD PROTRUSION
ORDERING REFERENCE THREAD SIZE ACROSS FLATS 'A' ACROSS CORNERS 'A'
LENGTH LENGTH 'B'
747 RECESSED
NON-TAMPER √ √ √ √ √ √ 757DM1 M16 X 1.5 15.0 22.0 24.2 5.0
PROOF TYPE ‘A’
757DM2 M20 X 1.5 15.0 24.0 26.4 5.0
747 RECESSED
TAMPER-PROOF √ √ √ √ √ √ 757DM3 M25 X 1.5 15.0 30.0 33.0 5.0
TYPE ‘B’
757DM4 M32 X 1.5 15.0 36.0 39.6 5.0
757
x √ √ √ √ √ 757DM5 M40 X 1.5 15.0 46.0 50.6 5.0
HEXAGON HEAD
757DM6 M50 X 1.5 15.0 55.0 60.5 5.0
757
HEXAGON HEAD x √ √ √ √ √ 757DM7 M63 X 1.5 15.0 70.0 77.0 5.0
C/W ‘O’ RING SEAL
757DM8 M75 X 1.5 15.0 80.0 88.0 5.0
767
√ √ √ √ √ √ 757DM9 M90 X 2.0 24.0 99.0 108.9 5.0
DOME HEAD
757DM10 M100 x 2.0 24.0 108.0 118.8 5.0
767
DOME HEAD √ √ √ √ √ √ All dimensions shown are in millimetres unless otherwise stated
C/W ‘O’ RING SEAL

Dimensions listed are for metric cable glands only. Dimensions for alternative threads may vary, please see supplementary technical data sheet TDS503NPT.

www.cmp-products.com TDS503 REV16 09/20