Catalyst 3560
Catalyst 3560
1 2
SYST 3 4
1X 5 6
RPS 7 8 9 10 11
STAT 12 13 14 15
DUPLX 16
SPEED 17 18 19 20
PoE 15X 17X 21 22 23 24 25 26
MODE 2X 27 28 29 30 31 32
33 34 35 36
31X 33X 37 38 39 40 41 42
16X
18X 43 44 45 46 Catalyst 3560
47 48 G SERIES PoE
-48
47X
32X 34X
49
51
48X 50
52
Two 19-inch
mounting brackets
ul f or 56
at ng
at et th 0
G
al S
or y e S
e
ys t
a
C
y Inf
at
t 3 art
C o
al
om rm
56 ed
f
ys
0 G
P
pl ati
C
t3
is
ro
S ui
ia on
co
w de
d
nc
u
R
itc
ct
eg
e
h
is
O
tr
w
w
a
tio
itc
ne ard
n
rs
h
c
hi
p
Documentation
SYST
STAT
CONSOL
DPLX E 1x
SPD 2x
PoE 3x
4x
5x
6x
MODE 7x Catalyst 35
8x
60 SERIES Po
E-8
Mounting magnet
Console cable
Screw template
AC power cord
(AC-powered switches only)
Three number-8
Phillips pan-head screws
R nd
eg S
a
C tti
ul f or 56
at ng
at et th 0
G
al S
or y e S
e
ys t
a
C
y Inf
at
t 3 art
C o
al
om rm
56 ed
f
ys
0 G
pl ati
t3
S ui
ia on
w de
nc
itc
e
P
h
is
ro
w
co
d
itc
u
R
ct
eg
h
is
O
tr
w
at
ne ard
io
n
rs
c
hi
p
MODE 2X
Step 6 Verify that the switch is in Express Setup mode by confirming that all LEDs left of the
Mode button are green. (On some models, the RPS and PoE LEDs remain off.)
STAT
DUPLX
SPEED
PoE
1X
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
15X 17X
17 18 19 20 21 22 23 24 25 26
MODE 2X 27 28
panel.
29 30 31 32
33 34 35 36
31X 33X 37 38 39 40 41 42
16X
18X 43 44 45 46 Catalyst 3560G
47 48 SERIES
PoE-48
47X
32X 34X
49
51
DHCP-enabled PC
Step 8 Verify that the LEDs on both Ethernet ports are green.
Wait 30 seconds.
Step 9 Start a web browser on your PC.
Enter the IP address 10.0.0.1 in the
web browser, and press Enter.
The Express Setup page appears. If it does not appear, see the “In Case of Difficulty”
section on page 23 for help.
Note Enabling IPv6 restarts the switch when you complete Express Setup.
Step 15 To complete Express Setup, click Submit from the Basic Settings or the Advanced Settings
tab to save your settings, or click Cancel to clear your settings.
When you click Submit, the switch is configured and exits Express Setup mode. The PC
displays a warning message and tries to connect with the new switch IP address. If you
configured the switch with an IP address that is in a different subnet from the PC,
connectivity between the PC and the switch is lost.
Step 16 Disconnect the switch from the PC, and install the switch in your production network. See
the “Managing the Switch” section on page 9 for information about configuring and
managing the switch.
If you need to rerun Express Setup, see the “Resetting the Switch” section on page 24.
Command-Line Interface
You can enter Cisco IOS commands and parameters through the CLI. Access the CLI either by
connecting your PC directly to the switch console port or through a Telnet session from a remote PC
or workstation.
Follow these steps:
1. Connect the supplied RJ-45-to DB-9 adapter cable to the standard 9-pin serial port on the PC.
Connect the other end of the cable to the console port on the switch.
2. Start a terminal-emulation program on the PC.
3. Configure the PC terminal emulation software for 9600 baud, 8 data bits, no parity, 1 stop bit,
and no flow control.
4. Use the CLI to enter commands to configure the switch. See the software configuration guide and
the command reference for more information.
10
Note A drill is required if you are securing the Catalyst 3560-8PC switch to a desk or a wall.
• Airflow around the switch and through the • Do not place any items on the top of the
vents is unrestricted. Catalyst 3560-8PC switch.
• The heatsinks and the bottom of the
Catalyst 3560-8PC switch might be hot to
Note We strongly recommend that you allow
the touch if the switch is operating at its
at least 3 inches (7.6 cm) of clearance
maximum temperature 113˚F (45˚C) and is in
around the ventilation openings.
an environment that exceeds normal room
temperature (such as in a closet, in a cabinet,
• Temperature around the switch does not or in a closed or multirack assembly).
exceed 113˚F (45˚C).
• Allow at least 1.75 inches (4 cm) of clearance
• Humidity around the switch does not exceed above each Catalyst 3560-8PC switch in the
85 percent. rack.
• Altitude at the installation site is not greater
than 10,000 feet.
11
Warning Only trained and qualified personnel should be allowed to install, replace, or service this
equipment. Statement 148
Warning To prevent the switch from overheating, do not operate it in an area that exceeds the
maximum recommended ambient temperature of 113˚F (45˚C). To prevent airflow
restriction, allow at least 3 inches (7.6 cm) of clearance around the ventilation openings.
Statement 17B
12
Warning To prevent bodily injury when mounting or servicing this unit in a rack, you must take
special precautions to ensure that the system remains stable. The following guidelines
are provided to ensure your safety:
• This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
• When mounting this unit in a partially filled rack, load the rack from the bottom to the top
with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before mounting or
servicing the unit in the rack. Statement 1006
Warning This equipment is intended to be grounded. Ensure that the host is connected to earth
ground during normal use. Statement 39
Warning If a redundant power system (RPS) is not connected to the switch, install an RPS
connector cover on the back of the switch. Statement 265
13
Warning Voltages that present a shock hazard may exist on Power over Ethernet (PoE) circuits if
interconnections are made using uninsulated exposed metal contacts, conductors, or
terminals. Avoid using such interconnection methods, unless the exposed metal parts
are located within a restricted access location and users and service people who are
authorized within the restricted access location are made aware of the hazard. A
restricted access area can be accessed only through the use of a special tool, lock and
key or other means of security. Statement 1072
Note This section applies to all Catalyst 3560 switches except the Catalyst 3560-8PC switch. For
installation information for the Catalyst 3560-8PC switch, see “Securing the Switch on a Desk
or Shelf (only the Catalyst 3560-8PC Switch)” section on page 17 and “Mounting the Switch
with a Magnet Panel (only the Catalyst 3560-8PC Switch)” section on page 19.
This section covers basic 19-inch rack-mounting. As an example, all the illustrations show the
Catalyst 3560G-48PS switch. You can install and connect other Catalyst 3560 switches except the
Catalyst 3560-8PC switch as shown in these illustrations.
14
1 2
SYST 3 4
1X 5 6
RPS 7 8 9 10 11
STAT 12 13 14 15
DUPLX 16
SPEED 17 18 19 20
PoE 15X 17X 21 22 23 24 25 26
MODE 2X 27 28 29 30 31 32
33 34 35 36
31X 33X 37 38 39 40 41 42
16X 18X 43 44 45 46 Catalyst 356
47 48 0G SERIES PoE
-48
47X
32X 34X
49
51
48X 50
52
Front-mounting position
Number-8 Phillips
flat-head screws
1 2
SYST 3 4
1X 5 6
RPS 7 8 9 10 11
STAT 12 13 14 15
DUPLX 16
SPEED 17 18 19 20
PoE 15X 17X 21 22 23 24 25 26
MODE 2X 27 28 29 30 31 32
33 34 35 36
31X 33X 37 38 39 40 41 42
16X 18X 43 44 45 46 Catalyst 356
47 48 0G SERIES PoE
-48
47X
32X 34X
49
51
48X 50
52
CONSOL
E
DC INP
UTS FOR
POWE REMOTE
SPECIF R SUPPLY
IED IN
MANUA
L
Rear-mounting position
15
Cable
guide
1 2
SYST 3 4
1X 5 6
RPS 7 8 9 10 11
STAT 12 13 14 15
DUPLX 16
SPEED 17 18 19 20
PoE 15X 17X 21 22 23 24 25 26
MODE 2X 27 28 29 30 31 32
33 34 35 36
31X 33X 37 38 39 40 41 42
16X 18X 43 44 45 46 Catalyst 356
47 48 0G SERIES PoE
-48
47X
32X 34X
49
51
48X 50
52
Number-12 Phillips
machine screws
1 2
SYST 3 4
1X 5 6
RPS 7 8 9 10 11
STAT 12 13 14 15
DUPLX 16
SPEED 17 18 19 20
PoE 15X 17X 21 22 23 24 25 26
MODE 2X 27 28 29 30 31 32
33 34 35 36
31X 33X 37 38 39 40 41 42
16X 18X 43 44 45 46 Catalyst 356
47 48 0G SERIES PoE
-48
47X
32X 34X
49
51
48X 50
52
CONSOL
E
DC INP
UTS FOR
POWER REMOTE
SPECIF SUPPLY
IED IN
MANUAL
Rear-mounting position
16
Note This section is specific to the Catalyst 3560-8PC switch. For installation information for other
Catalyst 3560 switches, see “Rack-Mounting the Switch (All Catalyst 3560 Switches Except
the Catalyst 3560-8PC Switch)” section on page 14.
To place the switch on a desk without using the mounting screws, simply attach the four rubber feet
on the bottom panel of the switch.
To secure the switch on top of or under a desk or a shelf, or on a wall, use the mounting template and
three mounting screws. Follow these steps:
1. Position the screw template on the mounting surface with the two side-by-side slots forward. Peel
the adhesive strip off the bottom, and attach the template.
2. Use a 0.144-inch (3.7 mm) or a #27 drill bit to drill a 1/2-inch (12.7 mm) hole in the three template
screw slot positions.
3. Insert the screws in the slots on the template, and tighten until they touch the template. Remove
the template from the mounting surface.
Mounting template
17
SYST
STAT
CONSOL
DPLX E 1x
SPD 2x
PoE 3x
4x
5x
6x
MODE 7x Catalyst 35
8x
60 SERIES Po
E-8
18
Note This section only applies to the Catalyst 3560-8PC switch. For installation information for all
other Catalyst 3560 switches, see “Rack-Mounting the Switch (All Catalyst 3560 Switches
Except the Catalyst 3560-8PC Switch)” section on page 14.
Mounting magnet
E-8
60 SERIES Po
Catalyst 35
8x
7x
6x
5x
4x
3x SPD
2x DPLX
1x E
CONSOL STAT
SYST
SYST
19
STAT
1X 6 7 8 9 10 11 12 13 14 15
straight-through, twisted four-pair, DUPLX
SPEED
PoE
16
15X
The fixed ports on the Catalyst 3560 Power over Ethernet (PoE) switches provide PoE support for
devices compliant with IEEE 802.3af and also provide Cisco pre-standard PoE support for Cisco
IP Phones and Cisco Aironet Access Points.
Each of the Catalyst 3560-24PS switch 10/100 ports or the Catalyst 3560G-24PS switch 10/100/1000
ports can deliver up to 15.4 W of PoE. On the Catalyst 3560-48PS or 3560G-48PS switches, any 24
of the 48 10/100 or 10/100/1000 ports can deliver 15.4 W of PoE, or any combination of the ports
can deliver an average of 7.7 W of PoE at the same time, up to a maximum switch power output of
370 W.
By default, a Catalyst 3560 switch PoE port automatically provides power when a valid powered
device is connected to it. For information about configuring and monitoring PoE ports, see the switch
software configuration guide. For information about troubleshooting PoE problems, see the Catalyst
3560 Switch Hardware Installation Guide on Cisco.com.
Note For simplified cabling, the automatic medium-dependent interface crossover (auto-MDIX)
feature is enabled by default on the switch. With auto-MDIX enabled, the switch detects the
required cable type for copper Ethernet connections and configures the interfaces accordingly.
Therefore, you can use either a crossover or a straight-through cable for connections to a
switch 10/100 or 10/100/1000 Ethernet port, regardless of the type of device on the other end
of the connection.
20
34X 1
49
2
51
1
48X 50 2
52
SFP module
50 2
52
Step 3 Insert the other cable end into the other device.
For a list of supported modules, see the release notes on Cisco.com. For detailed instructions on
installing, removing, and connecting to SFP modules, see the documentation that came with the SFP
module.
Caution Removing and installing an SFP module can shorten its useful life. Do not remove and
insert SFP modules more often than is absolutely necessary.
21
210092
configurable.
Step 2 Insert the other cable end into the other device.
22
• Did you verify that POST successfully ran If not, make sure that only the SYST and STAT
before starting Express Setup? LEDs are green before pressing the Mode button
to enter the Express Setup mode.
• Did you press the Mode button while the If yes, wait until POST completes. Power cycle the
switch was still running POST? switch. Wait until POST completes. Confirm that
the SYST and STAT LEDs are green. Press the
Mode button to enter Express Setup mode.
• Did you try to continue without confirming Verify that all LEDs left of the Mode button are
that the switch was in Express Setup mode? green. (On some models, the RPS LED is off.) If
necessary, press the Mode button to enter Express
Setup mode.
• Does your PC have a static IP address? If yes, change your PC settings to temporarily use
DHCP before connecting to the switch.
• Did you connect a crossover cable instead of If yes, connect a straight-through cable to an
a straight-through Ethernet cable between a Ethernet port on the switch and the PC. Wait 30
switch port and the Ethernet port of the PC? seconds before entering 10.0.0.1 in the browser.
• Did you connect the Ethernet cable to the If yes, disconnect from the console port. Connect
console port instead of to a 10/100 or to an Ethernet port on the switch and the PC.
10/100/1000 Ethernet port on the switch? Wait 30 seconds before entering 10.0.0.1 in the
browser.
23
• Did you enter the wrong address in the If yes, re-enter 10.0.0.1 in the browser, and press
browser, or is there an error message? Enter.
Caution Resetting the switch deletes the configuration and reboots the switch.
To reset the switch, press and hold the Mode button. The switch LEDs begin blinking after about 3
seconds. Continue holding down the Mode button. The LEDs stop blinking after 7 more seconds, and
then the switch reboots.
The switch now behaves like an unconfigured switch. You can enter the switch IP information by using
Express Setup as described in the “Running Express Setup” section on page 5.
24
25
Cisco.com
You can access the most current Cisco documentation at this URL:
http://www.cisco.com/techsupport
You can access the Cisco website at this URL:
http://www.cisco.com
You can access international Cisco websites at this URL:
http://www.cisco.com/public/countries_languages.shtml
Ordering Documentation
You must be a registered Cisco.com user to access Cisco Marketplace. Registered users may order
Cisco documentation at the Product Documentation Store at this URL:
http://www.cisco.com/go/marketplace/docstore
If you do not have a user ID or password, you can register at this URL:
http://tools.cisco.com/RPF/register/register.do
26
27
Tip We encourage you to use Pretty Good Privacy (PGP) or a compatible product (for example,
GnuPG) to encrypt any sensitive information that you send to Cisco. PSIRT can work with
information that has been encrypted with PGP versions 2.x through 9.x.
Never use a revoked encryption key or an expired encryption key. The correct public key to
use in your correspondence with PSIRT is the one linked in the Contact Summary section of
the Security Vulnerability Policy page at this URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html
The link on this page has the current PGP key ID in use.
If you do not have or use PGP, contact PSIRT to find other means of encrypting the data before
sending any sensitive material.
28
Note Use the Cisco Product Identification Tool to locate your product serial number before
submitting a request for service online or by phone. You can access this tool from the
Cisco Technical Support & Documentation website by clicking the Tools & Resources link,
clicking the All Tools (A-Z) tab, and then choosing Cisco Product Identification Tool from
the alphabetical list. This tool offers three search options: by product ID or model name; by
tree view; or, for certain products, by copying and pasting show command output. Search
results show an illustration of your product with the serial number label location highlighted.
Locate the serial number label on your product and record the information before placing a
service call.
If you suspect that the browser is not refreshing a web page, force the browser to update the
web page by holding down the Ctrl key while pressing F5.
To find technical information, narrow your search to look in technical documentation, not the
entire Cisco.com website. On the Cisco.com home page, click the Advanced Search link under
the Search box and then click the Technical Support & Documentation radio button.
To provide feedback about the Cisco.com website or a particular technical document, click
Contacts & Feedback at the top of any Cisco.com web page.
29
30
31
3. To read translated and localized warranty information about your product, follow these steps:
a. Enter this part number in the Warranty Document Number field:
78-6310-02C0
b. Select the language in which you would like to view the document.
32
33
Cisco Systems has more than 200 offices in the following countries. Addresses, phone numbers, and fax numbers are listed on the
Cisco Website at www.cisco.com/go/offices
Argentina • Australia • Austria • Belgium • Brazil • Bulgaria • Canada • Chile • China PRC • Colombia • Costa Rica • Croatia • Cyprus • Czech Republic • Denmark • Dubai, UAE
Finland • France • Germany • Greece • Hong Kong SAR • Hungary • India • Indonesia • Ireland • Israel • Italy • Japan • Korea • Luxembourg • Malaysia • Mexico
The Netherlands • New Zealand • Norway • Peru • Philippines • Poland • Portugal • Puerto Rico • Romania • Russia • Saudi Arabia • Scotland • Singapore
Slovakia • Slovenia • South Africa • Spain • Sweden • Switzerland • Taiwan • Thailand • Turkey • Ukraine • United Kingdom • United States • Venezuela • Vietnam • Zimbabwe
CCVP, the Cisco Logo, and the Cisco Square Bridge logo are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn
is a service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco, the
Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity,
Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, Follow Me Browsing, FormShare, GigaDrive, GigaStack, HomeLink, Internet
Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick Study, LightStream, Linksys, MeetingPlace, MGX, Networking
Academy, Network Registrar, Packet, PIX, ProConnect, RateMUX, ScriptShare, SlideCast, SMARTnet, StackWise, The Fastest Way to Increase Your
Internet Quotient, and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply
a partnership relationship between Cisco and any other company. (0609R)
78-16660-04
DOC-7816660=