Advanced Radar Level Transmitters
Advanced Radar Level Transmitters
Powder
Liquid
Extended the product warra
Matsushima's radar level transmitter is manufactured domestically from software to hardware,
so it can be delivered quickly with stable supply, and also support our customers with quick
maintenance. Since Matshushima has 60 years of experience in measurement control,
we are able to meet our customer's requests regarding installation to the facilities.
Customization
Customize the level meter for suitable measuring environments and usage. Able to provide
customized level meter in applications that have restrictions under high temperature and high
pressure areas.
Sunshade Cover Flat Antenna Cooling box Heat protection fin Dust cap
(installation limitation) (installation limitation) (high temperature) (high temperature) (against dust intrusion)
Applications
Applies to a variety of applications and flexible customization capability
based on our long experience and know-how.
Usage in Applications
If there’s no space to install on By attaching the PTFE Narrow beam angle allows to
top of the silo, it is able to antenna, it is able to measure measure inside a thin, long
measure from the side of the corrosive chemicals. grain silos.
silo.
Mobile tripper
Combustion air
Able to continuously measure Even if antenna is not allowed It can follow a sudden level
without being affected by rain, to be put inside, it can be change in bunker. Dust and
wind, and snow. measured by flat antenna vapor do not influence level
type. measurement.
It is suitable for vertial shaft or The liquid level can be PTFE coating antenna prevents
crusher due to high measured without foam the material from being built up
tracking-speed performance. intrusion into piping. on the antenna, and results in
stable level measurement.
Well experienced in Displays with 4 languages
ation
Application Supports Outstanding operation
Easy Operation
Simple and precise operation possible. Site maintenance with simple hand
communicator "GRAPHIC COM4". Remote operation with customer friendly software.
"GRAPHIC COM 4 ", a detachable LCD The PC with adjustment software allows
Local adjuster, has a liquid crystal display with Remote easy operation for complex parameter
high - visibility. You can see waveforms in settings.
Operation real time while monitoring, and you can Operation
adjust settings if needed.
HART Communication
Data communication
cable (option)
GRAPHIC COM4 Real time indication for
on the sensor head measurement situation
Software Features
∙ Real time indication for measurement
situation
∙ Make adjustment
∙ Check waveforms while monitoring and store
the data
∙ Record trends
∙ Languages: Japanese, English, Chinese, and
Korean
Version
upgrade High measuring performance under any conditions
er r
r (form itte
Rada sm
For powder ≦1.
2m:±20mm 6.2s
ct ran
±50mm oni
H7、H3 >1.
2m:±10mm 5 ras
Ult ) 5.2s
2.6s
ew v ersion
Ra dar (n cf., 10m level change tracked by
For liquid ≦1.
2m:±30mm 1.6s fastest 1.6 sec.oved accuarcy
±50mm
H2、H1、C1 >1.
2m:±20mm 0 10m 70m
Measuring distance(m)
*Response time depends on measuring distance & adjustments
4
For Liquid Specifications
Model MWLM-PR26C* MWLM-PR26H*
Product Code MWLM-PR26C1G* MWLM-PR26H1G MWLM-PR26H2G* MWLM-PR26H2F*
Antenna Cone Horn
Power Supply
Standard: DC13 - 36V 1 DC16V or more is required for LCD unit.
*
Power Consumption
Ex-proof: DC20 - 32V 2 Power supplied by safety barrier KFD2-STC4-Ex1
Standard type: Approx. 704mW, Explosion-proof: Approx. 540mW
*
Mounting G2 Thread G1 Thread G1 1/2 Thread JIS5K50A Flange
Dead Zone 0.5m (1.64ft) below the antenna
Max Measurable Distance 10.0 m (33ft) from measuring reference zero point 20.0 m (66ft) from measuring reference zero point
Transmitting Frequency Approx. 26GHz
Transmitting Cycle Every 83ms
Beam Angle Approx. 24 (approx. 48deg. including side beam) Approx. 18 (approx. 36deg. including side beam)
Resolution 1mm
Allowable Fluctuation Rate 10cm/s
Repeatability Within 1.2m (3.94ft) or less: ± 30mm (1.18in), Over 1.2m (3.94ft) or more: ± 20mm (0.78in) or ± 0.04% of measurement range (Whichever is greater)
Accuracy
Temp. Error Standard: ± 0.03% /10K, Ex-proof: 0.06%/6K
Standard: -40 ∼ +80℃ (-40 ∼ +176℉ ), With LCD: -20 ∼ +60℃ (-4 ∼ +140℉ ), Ex-proof: -20 ∼ +50℃ (-4 ∼ +122℉ )
Ambient Housing
1 hour is required to warm up the device if the temperature is lower than -20℃ (-4℉ ).
Temperature
Antenna Standard: -40 ∼ +150℃ (-40 ∼ +302℉ ), Ex-proof: -40 ∼ +100℃ (-40 ∼ +212℉ )
Allowable Pressure 500kPa 1MPa 490kPa
Housing ADC
Material
Antenna PTFE SUS304 SUS316L
Protection IP67 (Housing cover and lead outlet must be closed)
Lead Outlet 1-G1/2 (Applicable cable size: ϕ 8 to 12mm (0.31 to 0.47in)
Output Signal DC4 ∼ 20mA × 1 (Load resistance when 24VDC power supply is used; 499 Ω max), HART communication
Integral Time 0 ∼ 999s
Mass Approx. 1.9kg Approx. 1.6kg Approx. 1.9kg Approx. 2.2kg
Explosion-proof Intrinsically safe construction Intrinsically safe construction
−
construction Ex ia ⅡB T4 X (TIIS) Ex ia ⅡB T4 X (TIIS)
Division of Housing Zone1, Zone2 − Zone1, Zone2
hazadous
section Antenna Zone1, Zone2 − Zone0, Zone1, Zone2
・LCD adjustment unit (GRAPHIC COM4) ・Data Communication cable (MHM-01) ・PC adjustment software (M-DTM)
Accessories (option)
Safety barrier (KFD2-STC4-Ex1) is needed to use the explosion proof type. LCD display can't be used since it's a non explosion proof parts.
*: Explosion Proof model has Ex written at the end of each model. Explosion proof structure is Ex ia ⅡB T4 (TIIS).
●Dimension mm [in]
Model : MWLM-PR26
C1G H1G H2G ϕ1
H2F
30
[ϕ
( ϕ 104) [4.09”] ( ϕ 104) [4.09”] A 5.1 ( ϕ 104) [4.09”]
A ( ϕ 104) [4.09”] P.C.D.1 2” ] A
A 05 [ ϕ 4
.13”]
D D D
D
(82) [3.24”]
B
(82) [3.24”] (82) [3.24”]
(82) [3.24”]
(255) [10.04”]
(199) [7.83”]
(199) [7.85”]
E
20 [0.79”]
(292) [11.49”]
(405) [15.94”]
(312) [12.30”]
(249) [9.80”]
E E
F
E
14 [0.55”]
(405) [15.94”]
G G F
(93) [3.66”]
G
(113) [4.45”]
150 [5.91”]
ϕ 26 [1.02”] G
(156) [6.14”]
150 [5.91”]
ϕ 45 [1.77”]
ϕ 49 [1.92”]
A Lead outlet: G1/2 Cable: ϕ 8-12mm [0.31-0.47” ]
B 4×ϕ15 [0.59” ] Mounting hole ϕ 49 [1.92”]
C 8×ϕ 19 [0.75” ] Mounting hole
D Earth terminal (M4) Be sure to ground the earth terminal. (D-class grounding)
E Housing Housing rotatable in 310˚.
F Purge nozzle: Rc1/8
G Measurement reference zero poin
Common for Liquid & Powder Terminal Block Specs & Dimensions of the safety barrier
HART I/F Check Terminal
115 (4.53") 20 Specifications
(0.79") Power Specs.
・Power Supply: DC20 ~ 35V
Power supply for
・Power Consumption: 1.9kW
LCD adjustment
unit (+(
)−)
Input Specs.
1 2
・Input Signal: 0/4 ~ 20mA
123 (4.84")
・Available voltage:
Power supply/Current output*
≧16V at 20mA terminal 1+, 3
DC13~36V/DC4 ~ 20mA
M4 Earth Output Specs. (Safety area)
Terminal ・Output signal:
Lead Outlet
0/4~20mA ; load 0~500Ω
・Pulsating Current: ≦50 μ A rms
* : Two wire shielded cable is recommended.
For explosion-proof type, provide the power
Mass: 200g (0.44lbs)
through the Safety Barrier.
※This product uses a connection to the distributor or isolated interface(HART supported) and a card as a basic connection.
For other connection methods and for any questions, please contact us.
CMWPR-208E
Feb.2020
*: Explosion Proof model has Ex written at the end of each model. Explosion proof structure is Ex ia ⅡB T4 (TIIS).
●Dimension mm [in]
Model : MWLM-PR26
P.C P.C
ϕ2
ϕ2
H3G H3F H3S H7G .D H7F .D H7S
10
10
.1 .1
7 7
[ϕ
[ϕ
5[ 5[
ϕ1 ( ϕ 104) [4.09”] ( ϕ 104) [4.09”] ( ϕ 104) [4.09”]
8.2
8.2
55 ( ϕ 104) [4.09”] 6. 6.
ϕ
ϕ
[ϕ 89 89
7
7
”]
”]
”]
”]
6.1
( ϕ 104) [4.09”] P.C.D. 0” ] A ( ϕ 104) [4.09”] A
A 130 [ ϕ A A A
5.12”]
D D D
D D D
P.C
.D
B .17 C C
ϕ2
5[
6.8
10
C
ϕ
9” ] (82) [3.24”]
[ϕ
(255) [10.04”]
(245) [9.64”]
(255) [10.04”]
(271) [10.67”]
E
(249) [9.80”]
(271) [10.67”]
(36) [1.42”]
E E E
20 [0.79”]
E
10 [0.39”]
(36) [1.42”]
E
20 [0.79”]
14 [0.55”]
Max.10° Max.10°
Max.10° Max.10° F
(455) [17.91”]
(455) [17.91”]
F F
(455) [17.91”]
F F
F
G G G
G G G
(696) [27.40”]
(696) [27.40”]
(696) [27.40”]
10 [0.39”]
(206) [8.11”]
200 [7.87”]
10 [0.39”]
(184) [7.24”]
200 [7.87”]
(451) [17.76”]
441 [17.36”]
(425) [16.73”]