0% found this document useful (0 votes)
274 views10 pages

Deep Foundation Design and Load Analysis

The document describes the design of a bored pile with an enlarged base installed in stiff clay. It provides details on the soil properties, pile geometry, and calculations to determine the design/allowable load capacity considering factors of safety. It also examines a group of 36 piles supporting a load, calculating the factor of safety and total settlement of the group.

Uploaded by

Joseph Baruhiye
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
274 views10 pages

Deep Foundation Design and Load Analysis

The document describes the design of a bored pile with an enlarged base installed in stiff clay. It provides details on the soil properties, pile geometry, and calculations to determine the design/allowable load capacity considering factors of safety. It also examines a group of 36 piles supporting a load, calculating the factor of safety and total settlement of the group.

Uploaded by

Joseph Baruhiye
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

TR335: Tutorial on deep foundations

1. A bored pile with an enlarged base is to be installed in


a stiff clay whose characteristic undrained shear strength
(Su) increases linearly by 10kPa/m depth to Su of 220kPa
at the pile base. The saturated unit weight of the clay is
21kN/m3 and the unit weight of concrete is 23.5kN/m3.
Diameters of the pile shaft and base are 1.05m and
3.00m respectively. The pile extends from a depth of 4m
to 22m, the top of the under-ream being at a depth of
20m. Past experience indicates that skin friction (shaft
adhesion) coefficient α of 0.70 is appropriate for the
clay. Determine the design/ allowable load of the pile
ensuring an overall load factor of 2.0 and a load factor of
3.0 under the base when shaft resistance is fully
mobilized.
TR335: Tutorial on deep foundations
G.L
A bored pile with an
enlarged base is to be 4.0m 𝛾𝑠𝑎𝑡 = 21𝑘𝑁/𝑚3
installed in a stiff clay
whose characteristic 40 Su (kPa)
undrained shear
strength (Su) increases
linearly by 10kPa/m
depth to Su of 220kPa
at the pile base.

The saturated unit


weight of the clay is
21kN/m3. 16.0m 1.0m
I
Diameters of the pile
shaft and base are 10.0kPa
1.05m and 3.00m
respectively.
Su(z) = 10z
The pile extends from 1.05m
a depth of 4m to 22m,
the top of the under-
ream being at a depth 2.0m II
of 20m. 220
3.0m z (m)
TR335: Tutorial on deep foundations
G.L

Q B = AB 9.0SuB + γsat d
4.0m 𝛾𝑠𝑎𝑡 = 21𝑘𝑁/𝑚3 π32
= 9x220 + 21x22
4
40 Su (kPa) = 17.261MN

20
QIs = αPs 10zdz
z=4
20
10z 2
= 0.7xπx1.05x
2 4
= 4.43MN
16.0m 1.0m
I

10.0kPa
22
QII
s =α Ps (z). Su (z)dz
z=20
Su(z) = 10z 22
1.05m = 2πα (0.4875z
20

2.0m II
220
3.0m z (m)
TR335: Tutorial on deep foundations
G.L
I II
Wpile = Wpile + Wpile
4.0m 𝛾𝑠𝑎𝑡 = 21𝑘𝑁/𝑚3
πx1.052
= x16x23.5 +
40 Su (kPa) 4
1 π32
x x3.08
3 4

16.0m 1.0m
I
The lesser of
10.0kPa QB + QS
Q allowable = −W
F
or
QB
Su(z) = 10z Q allowable = + QS − W
Fb
1.05m
=11.3MN

2.0m II
220
3.0m z (m)
TR335: Tutorial on deep foundations
2. Thirty six piles, 0.60m in diameter, are spaced at
2.40m centres in a 6x6 group. The piles extend between
depths of 3 and 18m in a deposit of stiff clay 28m thick
overlying a bedrock. The characteristic undrained
strength of the clay at a depth of 18m is 145kPa and the
average characteristic value over the pile length is
105kPa. The following have also been determined for
the clay, α = 0.40, Eu = 65MN/m2, mv = 0.08m2/MN and
γsat = 21kN/m3. If the pile group supports a load of
21MN determine;
(1) The overall load factor of safety if the pile group’s
efficiency is 80% and
(2) The total settlement of the group.
TR335: Tutorial on deep foundations
G.L
Thirty six piles, 0.60m in
diameter, are spaced at 2.40m 3.0m
centres in a 6x6 group.

The piles extend between


depths of 3 and 18m in a
deposit of stiff clay 28m thick
overlying a bedrock.

The characteristic undrained


strength of the clay at a depth
of 18m is 145kPa and the 15.0m
average characteristic value
over the pile length is 105kPa.

The following have also been


determined for the clay, α =
0.40, Eu = 65MN/m2, mv =
0.08m2/MN.

10.0m

BEDROCK
TR335: Tutorial on deep foundations
G.L Consider single pile analysis;
3.0m Q B = AB 9.0SuB + γsat d
π(0.6)2
= 9x145 + 18x21
4
= 476kN
𝑠ℎ𝑎𝑓𝑡
𝑄𝑠 = As α𝑆𝑢
= 0.4xπx0.6x15x105
= 1,187.5kN
πx0.62
15.0m Wpile = x15x23.5
4
=100kN

Consider the piles in a group;

QB + QS
Q allowable + Wpile group = xnxE
F
476 + 1,187.5
21,000 + 100x36 = x36x0.8
F
F = 2.0
10.0m

BEDROCK
TR335: Tutorial on deep foundations
G.L
3.0m Assume a minimum raft plan for the
6x6, 0.6m dia 2.4m spacing pile group;

Raft width (=length) will be;


5x2.4 + 0.6 = 12.6m

Qnet on founding ground;


= Qapplied – Qexcavated overburden

15.0m = 21,000 - 3x21x(12.6)2 = 11MN


(Assume concrete replaces equal soil weight)

Assume an equivalent raft 2/3pile length


from pile top and load shedding at 1:4;

Equivalent raft dimensions = 17.6m square

10.0m

BEDROCK
TR335: Tutorial on deep foundations
G.L
3.0m 12.6m

10m

15.0m

17.6m

10.0m

BEDROCK
TR335: Tutorial on deep foundations
G.L
3.0m 12.6m

10m

17.6m
11
𝑞𝑎𝑝𝑝𝑙𝑖𝑒𝑑 = 2
= 0.036𝑀𝑁/𝑚2
17.6
𝑠𝑡𝑜𝑡𝑎𝑙 = 𝑠𝑢𝑛𝑑𝑟𝑎𝑖𝑛𝑒𝑑 + 𝑠𝑐𝑜𝑛𝑠𝑜𝑙𝑖𝑑𝑎𝑡𝑖𝑜𝑛
2 3
𝑞𝑎𝑝𝑝 𝐵 1 − 𝜗 𝐼𝑝
𝑠𝑡𝑜𝑡𝑎𝑙 = + 𝑞𝑎𝑝𝑝𝑙𝑖𝑒𝑑 𝑚𝑣 𝑛4 ∆𝑧𝑖
𝐸𝑢
𝑖=1

0.036𝑥17.6𝑥(1 − 0.52)𝑥0.82
=
65
+ 0.036𝑥0.08𝑥5𝑥 0.796 + 0.47 + 0.325
=6 + 22.9 = 28.9mm

You might also like