0% found this document useful (0 votes)
38 views2 pages

de 9325

The document describes a cable entry box with elastic membranes for cable entries between 6-16mm in diameter. The box is made of polypropylene, has IP55 protection, and measures 88x88x50mm. It can withstand ambient temperatures between -25 to +40 degrees Celsius and has passed glow wire, burning behavior, and toxicity tests to ensure safety.

Uploaded by

prasun.tcel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views2 pages

de 9325

The document describes a cable entry box with elastic membranes for cable entries between 6-16mm in diameter. The box is made of polypropylene, has IP55 protection, and measures 88x88x50mm. It can withstand ambient temperatures between -25 to +40 degrees Celsius and has passed glow wire, burning behavior, and toxicity tests to ensure safety.

Uploaded by

prasun.tcel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Cable entry via elastic membranes

DE 9325
1.5-2.5 mm², Cu 3~

with terminals
5-pole per pole 6 x 1.5 mm² sol, 4 x 2.5 mm² sol, 3 x 4 mm² sol
11 elastic membranes, closed cable entries, sealing range Ø 6-16 mm
with one cable entry in the bottom, sealing range Ø 6-16 mm
colour: grey, RAL 7035

rated insulation voltage Ui = 690 V a.c./d.c.

material PP (polypropylene)
degree of protection IP 55
width 88 mm
height 88 mm
depth 50 mm
weight 0,120 kg
tightening torque for terminal 1.2 Nm
in accordance with IEC 60670-22

Drawings

Dimension drawing

Detail mass

Box walls

Page 1 of 2
Gustav Hensel GmbH & Co. KG * Gustav-Hensel-Str. 6 * 57368 Lennestadt * Germany * Telefon: +49 (0)2723/609-0 * Fax: +49 (0)2723/60052 * Date: May 29. 2019
Cable entry via elastic membranes

DE 9325
1.5-2.5 mm², Cu 3~

Operating and ambient conditions


Application area Suitable for indoor installation and outdoor installation, protected
against weather influences
Ambient temperature Average value over 24 hours + 35 °C
Maximum value + 40 °C
Minimum value - 25 °C
Relative humidity 50% at 40° C
short-time
100% at 25° C
Fire protection in the event of internal faults Demands placed on electrical devices from standards and laws
Minimum requirements
- Glow wire test in accordance with IEC 60695-2-11:
- 650°C for boxes and cable glands
- 850°C for parts of insulating material necessary to retain current
carrying parts in position
Burning behaviour Glow wire test IEC 60695-2-11: 750 °C
UL Subject 94: V-2
Degree of protection against mechanical load IK07 (2 Joule)
Toxic behaviour halogen-free
silicone-free
"halogen-free" in accordance with the examination of the cables
and insulated wires - corrosiveness of fumes - as per IEC 60754-2
Note: For material properties see technical data.