Copper PVC Cable Specs & Data

This document provides specifications for single core copper conductor and PVC insulated cable, including: - Cable uses include grounding or internal wiring in dry locations. - Dimensions, weights, and standard lengths are provided for cable sizes from 1.5 to 10 mm2. - Electrical data like resistance, current carrying capacity, and short circuit current are specified.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
102 views2 pages

Copper PVC Cable Specs & Data

This document provides specifications for single core copper conductor and PVC insulated cable, including: - Cable uses include grounding or internal wiring in dry locations. - Dimensions, weights, and standard lengths are provided for cable sizes from 1.5 to 10 mm2. - Electrical data like resistance, current carrying capacity, and short circuit current are specified.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

I SO 4

I SO 1
Cu/PVC (NYA) - 450/750 VOLT
01 00

SNI 04-6629.3

40
1

5
ID16/03504 ID05/66527 ID21/05663

SINGLE CORE, COPPER CONDUCTOR AND PVC INSULATED CABLE


General Application : Used for grounding cable or internal wiring in dry location

DIMENSIONAL & MECHANICAL DATA

Nominal Approximately
Size Conductor Standard delivery length
shape Insula�on
Thickness Overall diameter Net weight

mm² - mm mm kg/km m
1.5 re 0.7 2.9 20 100/Coil
1.5 rm 0.7 3.0 21 100/Coil
2.5 re 0.8 3.5 32 100/Coil
2.5 rm 0.8 3.7 34 100/Coil
4 re 0.8 3.9 47 100/Coil
4 rm 0.8 4.3 51 100/Coil
6 re 0.8 4.4 67 100/Coil
6 rm 0.8 4.8 71 100/Coil
10 re 1.0 5.7 111 100/Coil
10 rm 1.0 6.2 119 100/Coil

ELECTRICAL DATA
Resistance at 20°C Current carrying capacity
DC at 30 °C Short circuit current of
Size Insula�on Min. conductor at 1.0 sec
Conductor In Pipe In Air
Max.
mm² Ω/km M.Ω.Km A kA
1.5 12.1 10 15 24 0.19
2.5 7.41 9 20 32 0.32
4 4.61 8 25 43 0.50
6 3.08 7 33 54 0.73
10 1.83 7 45 74 1.20
Note : This is general information only. For other specific requirement, please contact our marketing

2023
Cu/PVC/PVC (NYM) - 300/500 VOLT SNI 04-6629.4 Cu/PVC/PVC (NYY) - 0.6/1 (1.2) kV SNI IEC 60502-1
COPPER CONDUCTOR, PVC INSULATED AND PVC SHEATHED CABLE COPPER CONDUCTOR, PVC INSULATED AND PVC SHEATHED CABLE
General Application : Used for permanent indoor installation in conduit under plaster General Application : Used for permanent indoor or outdoor installation or laying in the ground
or exposed installation in dry location where not sustain mechanical demage

DIMENSIONAL & MECHANICAL DATA DIMENSIONAL & MECHANICAL DATA

Nominal Thickness Overall diameter Standard delivery length Nominal Thickness Approximately Standard delivery length
Conductor Approximately Size Conductor
Size shape Outer
shape Outer Net weight Drum Insula�on Net weight Coil Drum
Insula�on Min Max Coil Sheath Overall Diameter
Sheath
mm² - mm mm mm mm kg/km m mm² - mm mm mm kg/km m
2 x 1.5 re 0.7 1.2 7.6 10.0 114 50/100 2000 2 x 1.5 re 0.8 1.8 11 146 100 2000
2 x 2.5 re 0.8 1.2 8.6 11.5 148 50/100 2000 2 x 2.5 re 0.8 1.8 11 180 100 2000
2x4 re 0.8 1.2 9.6 12.5 206 50/100 2000 2x4 re 1.0 1.8 14 265 100 2000
2x6 re 0.8 1.2 10.5 13.5 264 - 1000 2x6 re 1.0 1.8 14 323 - 2000
2 x 10 re 1.0 1.4 13.0 16.5 428 - 1000 2 x 10 re 1.0 1.8 16 459 - 1000
3 x 1.5 re 0.7 1.2 8.0 10.5 135 50/100 2000 3 x 1.5 re 0.8 1.8 11 168 100 2000
3 x 2.5 re 0.8 1.2 9.2 12.0 177 50/100 2000 3 x 2.5 re 0.8 1.8 12 212 100 2000
3x4 re 0.8 1.2 10.0 13.0 249 - 1000 3x4 re 1.0 1.8 14 314 - 1000
3x6 re 0.8 1.4 12.0 14.5 336 - 1000 3x6 re 1.0 1.8 15 389 - 1000
3 x 10 re 1.0 1.4 14.0 17.5 528 - 1000 3 x 10 re 1.0 1.8 17 561 - 1000
4 x 1.5 re 0.7 1.2 8.6 11.5 162 50/100 2000 4 x 1.5 re 0.8 1.8 12 197 100 2000
4 x 2.5 re 0.8 1.2 10.0 13.0 220 50/100 2000 4 x 2.5 re 0.8 1.8 13 251 100 2000
4x4 re 0.8 1.4 11.5 14.5 313 - 1000 4x4 re 1.0 1.8 15 374 - 1000
4x6 re 0.8 1.4 12.5 16.0 415 - 1000 4x6 re 1.0 1.8 16 469 - 1000
4 x 10 re 1.0 1.4 15.5 19.0 651 - 1000 4 x 10 re 1.0 1.8 18 685 - 1000

ELECTRICAL DATA ELECTRICAL DATA


Resistance at 20°C Resistance at 20°C
DC Current carrying capacity Short circuit current of DC Current carrying capacity Short circuit current of
Size in air at 30 °C conductor at 1.0 sec
Size in air at 30 °C conductor at 1.0 sec
Conductor Insula�on Min. Conductor Insula�on Min.
Max. Max.
mm² Ω/km M.Ω.Km A kA mm² Ω/km M.Ω.Km A kA
1.5 12.1 11 19 0.19 1.5 12.1 11 19 0.19
2.5 7.41 10 25 0.32 2.5 7.41 10 25 0.32
4 4.61 9 34 0.50 4 4.61 9 34 0.50
6 3.08 7 44 0.73 6 3.08 7 44 0.73
10 1.83 7 61 1.20 10 1.83 7 61 1.20
Note : This is only general information. For other specific requirement, please contact our marketing Note : This is only general information. For other specific requirement, please contact our marketing