I SO 4
I SO 1
Cu/PVC (NYA) - 450/750 VOLT
01 00
SNI 04-6629.3
40
1
5
ID16/03504 ID05/66527 ID21/05663
SINGLE CORE, COPPER CONDUCTOR AND PVC INSULATED CABLE
General Application : Used for grounding cable or internal wiring in dry location
DIMENSIONAL & MECHANICAL DATA
Nominal Approximately
Size Conductor Standard delivery length
shape Insula�on
Thickness Overall diameter Net weight
mm² - mm mm kg/km m
1.5 re 0.7 2.9 20 100/Coil
1.5 rm 0.7 3.0 21 100/Coil
2.5 re 0.8 3.5 32 100/Coil
2.5 rm 0.8 3.7 34 100/Coil
4 re 0.8 3.9 47 100/Coil
4 rm 0.8 4.3 51 100/Coil
6 re 0.8 4.4 67 100/Coil
6 rm 0.8 4.8 71 100/Coil
10 re 1.0 5.7 111 100/Coil
10 rm 1.0 6.2 119 100/Coil
ELECTRICAL DATA
Resistance at 20°C Current carrying capacity
DC at 30 °C Short circuit current of
Size Insula�on Min. conductor at 1.0 sec
Conductor In Pipe In Air
Max.
mm² Ω/km M.Ω.Km A kA
1.5 12.1 10 15 24 0.19
2.5 7.41 9 20 32 0.32
4 4.61 8 25 43 0.50
6 3.08 7 33 54 0.73
10 1.83 7 45 74 1.20
Note : This is general information only. For other specific requirement, please contact our marketing
2023
Cu/PVC/PVC (NYM) - 300/500 VOLT SNI 04-6629.4 Cu/PVC/PVC (NYY) - 0.6/1 (1.2) kV SNI IEC 60502-1
COPPER CONDUCTOR, PVC INSULATED AND PVC SHEATHED CABLE COPPER CONDUCTOR, PVC INSULATED AND PVC SHEATHED CABLE
General Application : Used for permanent indoor installation in conduit under plaster General Application : Used for permanent indoor or outdoor installation or laying in the ground
or exposed installation in dry location where not sustain mechanical demage
DIMENSIONAL & MECHANICAL DATA DIMENSIONAL & MECHANICAL DATA
Nominal Thickness Overall diameter Standard delivery length Nominal Thickness Approximately Standard delivery length
Conductor Approximately Size Conductor
Size shape Outer
shape Outer Net weight Drum Insula�on Net weight Coil Drum
Insula�on Min Max Coil Sheath Overall Diameter
Sheath
mm² - mm mm mm mm kg/km m mm² - mm mm mm kg/km m
2 x 1.5 re 0.7 1.2 7.6 10.0 114 50/100 2000 2 x 1.5 re 0.8 1.8 11 146 100 2000
2 x 2.5 re 0.8 1.2 8.6 11.5 148 50/100 2000 2 x 2.5 re 0.8 1.8 11 180 100 2000
2x4 re 0.8 1.2 9.6 12.5 206 50/100 2000 2x4 re 1.0 1.8 14 265 100 2000
2x6 re 0.8 1.2 10.5 13.5 264 - 1000 2x6 re 1.0 1.8 14 323 - 2000
2 x 10 re 1.0 1.4 13.0 16.5 428 - 1000 2 x 10 re 1.0 1.8 16 459 - 1000
3 x 1.5 re 0.7 1.2 8.0 10.5 135 50/100 2000 3 x 1.5 re 0.8 1.8 11 168 100 2000
3 x 2.5 re 0.8 1.2 9.2 12.0 177 50/100 2000 3 x 2.5 re 0.8 1.8 12 212 100 2000
3x4 re 0.8 1.2 10.0 13.0 249 - 1000 3x4 re 1.0 1.8 14 314 - 1000
3x6 re 0.8 1.4 12.0 14.5 336 - 1000 3x6 re 1.0 1.8 15 389 - 1000
3 x 10 re 1.0 1.4 14.0 17.5 528 - 1000 3 x 10 re 1.0 1.8 17 561 - 1000
4 x 1.5 re 0.7 1.2 8.6 11.5 162 50/100 2000 4 x 1.5 re 0.8 1.8 12 197 100 2000
4 x 2.5 re 0.8 1.2 10.0 13.0 220 50/100 2000 4 x 2.5 re 0.8 1.8 13 251 100 2000
4x4 re 0.8 1.4 11.5 14.5 313 - 1000 4x4 re 1.0 1.8 15 374 - 1000
4x6 re 0.8 1.4 12.5 16.0 415 - 1000 4x6 re 1.0 1.8 16 469 - 1000
4 x 10 re 1.0 1.4 15.5 19.0 651 - 1000 4 x 10 re 1.0 1.8 18 685 - 1000
ELECTRICAL DATA ELECTRICAL DATA
Resistance at 20°C Resistance at 20°C
DC Current carrying capacity Short circuit current of DC Current carrying capacity Short circuit current of
Size in air at 30 °C conductor at 1.0 sec
Size in air at 30 °C conductor at 1.0 sec
Conductor Insula�on Min. Conductor Insula�on Min.
Max. Max.
mm² Ω/km M.Ω.Km A kA mm² Ω/km M.Ω.Km A kA
1.5 12.1 11 19 0.19 1.5 12.1 11 19 0.19
2.5 7.41 10 25 0.32 2.5 7.41 10 25 0.32
4 4.61 9 34 0.50 4 4.61 9 34 0.50
6 3.08 7 44 0.73 6 3.08 7 44 0.73
10 1.83 7 61 1.20 10 1.83 7 61 1.20
Note : This is only general information. For other specific requirement, please contact our marketing Note : This is only general information. For other specific requirement, please contact our marketing