Bungalow
Bungalow
A B C D E A B C D E
1.00
8.00 2.00
2.00 1.00 2.00 3.00 8.00 M 9.00 M
2.00 3.00 3.00 2.00 1.00 2.00 3.00 1.00
2.00
2.00
WF
1.00
1.00
HALF TRUSS 5
HALF TRUSS 4
RAFTER 2
C2F2
WF-1
C1F1
WF-1
C1F1
B-1 B-1 B-1
50 X 100 C PURLINS
1 C1F1 1 1 RB-1
@ 0.60 M ON CENTER
HALF TRUSS 3
RAFTER 2
4.50
2.80
2.80
2.80
2.80
2.80
2.80
ROOF BEAM LINE
FIREWALL
FIREWALL
WF-1
WF-1
WF-1
S-1
B-2
B-2
B-1
6
S-1 S-1
SS
SS
VA
U
TR
U
10 MM Ø RSB
LL
TR
WF-1 SPACED @ 400 MM
EY
EY
B-1
EY
ON CENTER
LL
TR
LL
ELEV: + 0.40 M WF-1
VA
U
B-2 B-2
VA
2 2 2 RB-1
SS
C1F1 C1F1 C1F1
0.70
TRUSS 2
GIRT TRUSS 1
WF-1
WF-1
11.50 M
11.50 M
9.50 M
9.5 M
3.70
3.70
3.70
3.70
3.70
ELEV: + 0.35 M
9.50
9.50
WF-1
RB-1
B-1
B-2
B-1
S-1 S-1
3.00
WF-1
WF-1
TRUSS 1
15.00 M
15.00 M
5.20
WF-1
10 MM Ø RSB
RB-1
SPACED @ 400 MM
ON CENTER
5.50
ELEV: + 0.40 M
WF-1 B-2 B-2
3
3 3 3
SS
C1F1 C1F1 C1F1
2
U
SS
TR
HALF TRUSS 2
WF-1
U
1.50
1.50
ELEV:
EY
TR
B-1
1
LL
+ 0.35 M
WF-1
EY
SS
VA
LL
VA
WF-1 U
TR
VA
B-1
3.00
3.00
3.00
3.00
HALF TRUSS 1
LL
B-2
B-1
WF-1
EY
WF-1 S-1 S-1 E
LL
TR
1.000.501.00
RB-1
WF-1
VA
U
SS
1.50
B-1
1
RAFTER 1 RAFTER 1
WF-1 B-1 B-1
RAFTER 1
RAFTER 1
4 4 4
1.50
RB-1
1.00
C1F1 C1F1 C1F1 2.00 3.00
2.00 1.00 5.00
3.50
3.50
1 FOUNDATION PLAN
S 1 SCALE 1:100 MTS
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL TYPICAL DRAWINGS UNLESS 1. ALL NON-LOAD BEARING TYPE CONCRETE BLOCKS HAVE A UNIT WEIGHT
OTHERWISE SHOWN OR NOTED. MODIFY TYPICAL DETAILS AS DIRECTED TO MEET NOT TO EXCEED 80 PCF FOR LOAD BEARING TYPE CONCRETE BLOCKS, A
SPECIAL CONDITIONS. MINIMUM COMPRESSIVE STRENGTH OF 6.90 MPA, SHALL BE DEVELOPED. FOOTING SCHEDULE
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL 2. PROVIDE 1-O/16 VERTICAL BARS AT CORNERS, INTERSECTIONS, END OF WALLS, FOOTING SIZE MM DEPTH OF REINFORCEMENTS
STEEL, MISCELLANEOUS IRON, PRE-CAST CONCRETE ETC. SHALL BE SUBMITTED AND EACH SIDE OF OPENINGS. FOOTING THICKNESS EXCAVATION TRANSVERSE-DIRECTION LONGITUDINAL-DIRECTION REMARKS
FOR ENGINEERS APPROVAL BEFORE FABRICATION. MARK A B H D TOP BOTTOM TOP BOTTOM
3. LINTEL BEAMS SHALL BEAR AT LEAST 8 INCHES (200 MM) ON EACH SIDE OF
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN, CHECK MASONRY WALL OPENING. 16Ø BARS 16 PCS -
WITH MECHANICAL AND ELECTRICAL CONTRACTORS FOR CIRCUITS, PIPE SLEEVES. F1 1000 L 300 MM 1200 MM -- --
@ 200 MM O.C 16Ø BARS
ETC. TO BE EMBEDDED IN CONCRETE. 4. WALL REINFORCEMENTS SHALL BE AS FOLLOWS
4. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PROVIDE ADEQUATE SHORINGS 5. REINFORCING BARS SHALL BE LAPPED A MINIMUM OF 30 BR DIAMETERS WHERE
AND BRACINGS OF THE STRUCTURE FOR ALL LOAD S THAT MAYBE IMPOSED DURING SPLICED DOWELS FROM CONCRETE FOOTINGS OR SLABS SHALL BE EXTENDED
CONSTRUCTION INTO THE BLOCK WALL A MINIMUM OF 30 BAR DIAMETERS, AND DOWELS TO
MATCH VERTICAL REINFORCEMENT OF WALL.
BEAM SCHEDULE
B. CONCRETE AND REINFORCEMENT 6. ALL CELLS CONTAINING REINFORCING BARS OR INSERTS SHALL BE SOLIDLY
BEAM SIZE REINFORCEMENTS
FILLED WITH CONCRETE GROUT (REFER TO SPECIFICATIONS.) TYPE OF WIDTH HEIGHT BAR SIZE AT SUPPORT AT MIDSPAN TORSION/
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH THE LATEST BUILDING STIRRUPS
CODE OF AMERICAN CONCRETE INSTITUTE (ACI-318). BEAM B H DIAMETER TOP B. BOTTOM B. TOP B. BOTTOM B. MIDDLE
D. FOUNDATION (MM) (MM) CONT. EXTRA CONT. EXTRA CONT. EXTRA CONT. EXTRA BARS
2. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH AT THE END OF
SPACING OF Ø10MM
TWENTY EIGHT (28) DAYS WITH CORRESPONDING MAXIMUM SIZE AGGREGATE AND 1. FOUNDATION FOOTING ON BORED PILE OR MICROPILE, INCLUDE PILECAP DESIGNS STIRRUPS
SLUMPS AS FOLLOWS. AND CONSTRUCTION SHALL BE DONE BY A REPUTABLE FOUNDATION CONTRACTOR, B-1 200 400 16 12 -- 12 -- 12 -- 12 -- --
(1 @ 0.05 M, 5 @ 0.10M, 5 @
AS APPROVED BY THE STRUCTURAL ENGINEER 0.15M, REST @ 0.20M O.C.)
LOCATION 28 DAYS STRENGTH MAX SIZE AGGREGATE MAX SLUMP
SPACING OF Ø10MM
CURBS & SLAB 3000 PSI (210KG/CM^2) 1 IN (25 MM) 4 IN (100 MM) E. STEEL B-2 150 400 16 6 -- 6 -- 6 -- 6 -- --
STIRRUPS
(1 @ 0.05 M, 5 @ 0.10M, 5 @
ON GRADE
0.15M, REST @ 0.20M O.C.)
0.30
3. ALL REINFORCING BARS SHALL CONFORM TO A615 GRADE 33 FOR DIA. 12
STRUCTURAL STEEL FRAMING TO INCLUDE MATERIAL SCHEDULES, ERECTION
AND SMALLER BARS AND GRADE 40 FOR DIA 16 AND LARGER BARS. COLUMN HOOPS
SCHEMES, AND DETAIL OF CONNECTIONS AND SPLICES FOR REVIEW AND APPROVAL
ARE ALL GRADE 40 BARS.
OF THE ENGINEER PRIOR TO ERECTION.
4. IN GENERAL, THE LATEST EDITION OF ACI-315, MANUAL TO STANDARDS PRACTICE
4. ALL STRUCTURAL WELDING SHALL CONFORM TO E 70XX.
DETAILING REINFORCED CONCRETE STRUCTURES SHALL BE ADHERED TO, UNLESS
OTHERWISE SHOWN OR NOTED
5. ALL STRUCTURAL STEEL SURFACE SHALL BE APPLIED WITH A SHOP COAT OF ZINC
0.30
0.30
1.00
1.00
CHROMATE PRIMER PAINT AFTER FABRICATION AND PRIOR TO ERECTION AND A 6-16 MM Ø VERTICAL BARS 6-16 MM Ø VERTICAL BARS
5. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS:
3 SECOND COAT OF THE SAME PAINT AFTER WELDING AND OR ERECTION. W/ 10 MM Ø CLOSED TIES W/ 10 MM Ø CLOSED TIES
SUSPENDED SLABS 4 IN (19 MM)
1 @ 50, 10 @ 100, REST 1 @ 50, 10 @ 100, REST
SLAB ON GRADE 1 41 IN (38 MM) 6. THE CONTRACTOR SHALL VERIFY ACTUAL DIMENSIONS SHOWN IN THESE DRAWINGS
WALLS ABOVE GRADE 1 IN (25 MM)
@200 MM O.C. @200 MM O.C.
AT JOBSITE PRIOR TO THE PREPARATION OF SHOP DRAWINGS.
BEAM STIRRUPS AND COLUMN TIES 1
1 2 IN (38 MM) 6-16 MM Ø FTG BARS 6-16 MM Ø FTG BARS
NOTES:
WHERE CONCRETE IS EXPOSED TO EARTH 2 IN (50 MM) SET BOTHWAYS SET BOTHWAYS
BUT POURED AGAINST FORMS 1. YIELD STRESS OF HOOPS = 60KSI
WHERE CONCRETE IS DEPOSITED 3 IN (75 MM)
6.
DIRECTLY AGAINST EARTH
8. CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, TABLE OF LAP SPLICE AND
GRAVEL FILL GRAVEL FILL
ANCHORAGE LENGTH
MINIMUM OF 1.20 M
MINIMUM OF 1.20 M
STOOLS, EQUIPMENTS, AND MECHANICAL BASES THAT ARE REQUIRED BY THE
ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS. LAP SPLICE LENGTH
TYPE "A" TYPE "B"
9. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7)
# 10 0.40 0.30 0.60 COMPACTED FILL
CONSECUTIVE DAYS IMMEDIATELY AFTER POURING BY THE USE OF WET BURLAP,
FOG SPRAYING, CURING COMPOUNDS OR OTHER APPROVED METHODS. # 12 0.45 0.35 0.60 COMPACTED FILL
6-16 MM Ø VERTICAL BARS 6-16 MM Ø VERTICAL BARS
# 16 0.61 0.40 0.60
10. STRIPPING OF FORMS AND SHORES: W/ 10 MM Ø CLOSED TIES W/ 10 MM Ø CLOSED TIES
# 20 0.71 0.56 0.60 1 @ 50, 10 @ 100, REST 1 @ 50, 10 @ 100, REST
0.30
0.30
FOUNDATION 24 HRS # 25 1.10 0.90 0.66 @200 MM O.C. @200 MM O.C.
# 25 1.40 0.20 0.66
SUSPENDED SLAP EXCEPT WHEN 8 DAYS
6-16 MM Ø FTG BARS 6-16 MM Ø FTG BARS
ADDITIONAL LOADS ARE IMPOSED # 32 1.90 1.40 1.12
SET BOTHWAYS SET BOTHWAYS
# 36 2.41 1.64 1.43
WALLS 18 HRS
NOTES:
0.40
0.40
10MMØ @ 8"C/C STIRRUPS 10MMØ @ 11"C/C STIRRUPS
2-20MMØ BOTTOM 2-20MMØ EX. BOTTOM
3-20MMØ BOTTOM
3-20MMØ BOTTOM 3-20MMØ BOTTOM
L/4 A2 2-20MMØ EX. BOTTOM L/4 B2 L/4 A2 2-20MMØ EX. BOTTOM L/4 B2
SECTION A2-A2 SECTION B2-B2
L/4 L/4 L/4 L/4
0.
L/4
L/4
60
DOWEL BARS TO MATCH
CHB VERT. VARS
60
0.
3/4 3/4
0.25
3 - Ø 10 BOT. BARS
L/4 L/4
60
0.
Ø 10 BOT. BARS @ 300 OC.
0.30
S SCALE 1:20MTS
D/3
2-2
D/3
D
D/3
MAIN REINFORCEMENTS TO BE
WHERE JOINT IS AT POINT OF CONTINUOUS (TOP & BOT. BASRS
STRESS PROVIDE SHEAR RODS
D/3D/3
WITH ENGINEERS APPROVAL
D/3
D
10 x 1000 LONG @ 300 O.C
TYPICAL DETAIL FOR BEAM TYPICAL BEAM CONSTRUCTION
5 OR SLAB CHANGE SOFFIT 6 JOINT DETAILS TYPICAL BEAM CONSTRUCTION
S 2-2 SCALE 1:20MTS S 2-2 SCALE 1:20MTS 7 JOINT DETAILS
S 2-2 SCALE 1:20MTS
25° 25°
VARIES 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 VARIES
1 TYPICALTRUSS DETAILS
S 2-3 SCALE 1:20 MTS
25°