TECHNICAL
GUIDELINES
         Prepared by the International Concrete Repair Institute    December 1998
         Guideline No. 03734
         Copyright © 1998 International Concrete Repair Institute
Guide for Verifying Field
Performance of Epoxy Injection
of Concrete Cracks
  TECHNICAL
  GUIDELINES
  Prepared by the International Concrete Repair Institute   December 1998
Guide for Verifying Field
Performance of Epoxy
Injection of Concrete Cracks
Guideline No. 03734
Copyright © 1998 International Concrete Repair Institute
All rights reserved.
International Concrete Repair Institute
3166 S. River Road, Suite 132, Des Plaines, IL 60018
Phone: 847-827-0830 Fax: 847-827-0832
Web: www.icri.org
E-mail: info@icri.org
          I N T E R N AT I O N A L
          I N S T I T U T E
                      About ICRI Guidelines                                Producers of this Guideline
          The International Concrete Repair Institute (ICRI)                     Task Group Members
          was founded to improve the durability of concrete
                                                                                   Robert W. Gaul, Chair
          repair and enhance its value for structure owners.
          The identification, development, and promotion of the                      David L. Barton
          most promising methods and materials is a primary                            Paul Derby
          vehicle for accelerating advances in repair technology.                    David F. Dorsch
          Working through a variety of forums, ICRI members                           Neal Kanaya
          have the opportunity to address these issues and
                                                                                      Gerry Searles
          to directly contribute to improving the practice of
          concrete repair.
              A principal component of this effort is to make
          carefully selected information on important repair                           Contributors
          subjects readily accessible to decision makers. During
          the past several decades, much has been reported in                           Larry Hagan
          the literature on concrete repair methods and materials                       Bill McCarty
          as they have been developed and refined. Nevertheless,                        Larry Olson
          it has been difficult to find critically reviewed infor                      Dennis Sack
          mation on the state of the art condensed into easy to                          Jeff Small
          use formats.
              To that end, ICRI guidelines are prepared by
          sanctioned task groups and approved by the ICRI
          Technical Activities Committee. Each guideline is designed              Acknowledgements
          to address a specific area of practice recognized as
                                                                                        Peter Barlow
          essential to the achievement of durable repairs. All
          ICRI guideline documents are subject to continual                            Mike Beckman
          review by the membership and may be revised as                              Peter H. Emmons
          approved by the Technical Activities Committee.                                John Goss
                                                                                       Peter Harwood
                 Technical Activities Committee                                       Morris Schupack
                            Robert W. Gaul, Chair                                      Jim Suermann
                             Samson Bandimere                                            John Trout
                               David L. Barton
                               Eric L. Edelson
                              Peter H. Emmons
                               Robert J. Gulyas
                                Peter Harwood
                              Kenneth M. Lozen
                             James E. McDonald
                                Jack A. Morrow
                                 Dennis Pinelle
                               Randall W. Poston
03734-                                                 Guide for Verifying field performance of epoxy injection of concrete cracks
                                                                                                                            I N T E R N AT I O N A L
                                                                                                                            I N S T I T U T E
                                                             Contents
                           1.0 Purpose and Scope.................................................................. 2
                           2.0 Quality Assurance/Quality Control Methods............................. 3
                                2.1 Visual Observation of Injection Process ............................ 3
                                2.2 Materials Testing............................................................... 4
                           		         2.2.1 Laboratory Tests....................................................... 4
                                      2.2.2 Field Tests................................................................ 5
                            2.3 Removal and Evaluation of Cores from
                           		Epoxy Adhesive Injected Concrete.................................... 6
                             2.4 NDT Methods for Quality Assurance
                           		 of Epoxy Adhesive Injection Repairs.................................. 7
                           		         2.4.1 Ultrasonic Pulse Velocity.......................................... 8
                           		         2.4.2 Impact Echo Test Method......................................... 8
                           		         2.4.3 Spectral Analysis of Surface Waves......................... 9
                           Cited References . ......................................................................... 9
                                This document is intended as a voluntary guideline for the
                                owner, design professional, and concrete repair contractor. It
                                is not intended to relieve the professional engineer or designer
                                of any responsibility for the specification of concrete repair
                                methods, materials, or practices. While we believe the infor
                                mation contained herein represents the proper means to achieve
                                quality results, the International Concrete Repair Institute must
                                disclaim any liability or responsibility to those who may choose
                                to rely on all or any part of this guideline.
Guide for Verifying field performance of epoxy injection of concrete cracks                                                              03734-
          I N T E R N AT I O N A L
          I N S T I T U T E
          1.0 Purpose                                               If there is any doubt that epoxy injection will
                                                                achieve the intended results, a pilot test program
          and     Scope                                         should be conducted prior to letting the full
                                                                repair contract to determine whether the repair
          The primary purpose of this document is to
                                                                objectives can be attained using the materials
          provide the contractor, engineer, owner, and
                                                                and equipment proposed for the work. The
          specifier with guidelines to assist in the devel
                                                                trial section can be used to evaluate bonding, to
          opment of performance specifications for
                                                                confirm that adequate crack filling is possible,
          epoxy adhesive injection work. Generally, the
                                                                and to obtain resin “standards” that are discussed
          performance is measured according to whether
                                                                in the following section. The quality assurance
          the epoxy adhesive has adequately filled the
                                                                program should also be evaluated during the
          crack and has cured in place. In many instances
                                                                trial phase. If results of the trial work prove to be
          a significant volume of repair work may take
                                                                inadequate and cannot be improved, other repair
          place before the quality assurance testing can
                                                                methods need to be explored. Only the materials
          be initiated. This document includes process-
                                                                and equipment proved to be successful in the
          control methods which can help to assure that
                                                                pilot test should be used in conducting the work
          satisfactory work is being performed. It is based
                                                                unless the contractor can demonstrate equally
          on the assumption that the cause and extent of
                                                                satisfactory results with alternate materials
          the cracking have been identified and that epoxy
                                                                or equipment.
          adhesive injection has been carefully selected as
                                                                    Although this guide is written for control
          an appropriate repair technique. The injection
                                                                of epoxy injection of cracked concrete, the
          contractor is able to control only the penetration,
                                                                quality assurance and quality control methods
          proper proportioning, and mixing of the epoxy
                                                                described herein are also appropriate for
          adhesive. Although it may be possible to remove
                                                                gravity-fed repairs of concrete cracks.
          some contaminants, the contractor cannot control
          the presence of contaminants within the crack
          which may inhibit bonding.                            2.0 Quality
                                                                Assurance/Quality
                                                                Control Methods
                                                                There are numerous methods available to evaluate
                                                                epoxy adhesive injection repairs. The quality
                                                                assurance program will be comprised of a number
                                                                of techniques, the amount and extent of testing
                                                                depending on the degree of assurance required.
                                                                Sections 2.1 and 2.2 discuss qualitative methods
                                                                of quality control which are usually conducted
                                                                by the contractor concurrent with the injection
                                                                work. Sections 2.3 and 2.4 deal with quality
                                                                assurance methods used to confirm performance
                                                                of the repair work.
                                                                2.1 Visual Observation of Injection Process
                                                                Useful information about the injection quality is
                                                                attained from a visual observation of the work. If
                                                                the crack is visible on both sides of the member,
                                                                then reasonable assurance that the crack is full
                                                                can be realized by observation of the material
                                                                exiting the ports along the crack when the
                                                                injection sequence described below is followed.
                                                                However, if only one side of the member is visible
                                                                it is more difficult to determine if adequate filling
Fig. 1: Injection showing port-to-port adhesive travel          has been achieved. When injecting sequentially
03734-                                           Guide for Verifying field performance of epoxy injection of concrete cracks
                                                                                                              I N T E R N AT I O N A L
                                                                                                              I N S T I T U T E
         through the ports along the crack, observing flow
         from the adjacent port indicates that material is
         moving along the crack but it does not necessarily
         ensure that adequate filling has been achieved.
         (Figure 1)
             Liquid epoxy adhesive, like all liquids, flows
         as a result of gravity and tends to seek the lowest
         level in a void. Recognizing this tendency is a
         great advantage in determining that full pene
         tration has been achieved. Starting injection at
         the lowest elevation in a crack and observing
         the progression of adhesive from port to port
         at successively higher elevation ports until the
         highest elevation port is reached provides a measure
         of assurance that the crack has been filled. If, after
         the crack is first full and the adhesive has gelled,
         the highest elevation port will not accept addi-
         tional injection adhesive, it is usually reasonable
         to assume that the adhesive has not drained out of
         the crack that was once filled. The more viscous
         liquid adhesives resist draining out of cracks.
         Low viscosity liquid adhesives will stay in narrow
         cracks because of capillary forces. However, it
         is always wise to attempt to re-inject the highest
         port before the adhesive has gelled.                     Fig. 2: ASTM D 695 compressive strength test.
         2.2 Materials Testing
         Quality assurance tests conducted either in the          difficult to fabricate in the field. Also, the-test
         field or the laboratory can determine with varying       results are much more sensitive to minor flaws in
         degrees of accuracy if the contractor has properly       the test specimens.
         proportioned and mixed the injection adhesive.               Not every project justifies a laboratory test
                                                                  because the time consumed and the expense of
         2.2.1 Laboratory Tests                                   the test may exceed the requirements of the project.
         The only way to determine quantitatively if an           Critical structural applications usually demand
         epoxy adhesive is properly proportioned and              definitive tests and the specifying authority must
         mixed is to conduct a physical test under labor         decide for each project whether quantitative tests
         atory conditions. The two most common methods            are justified. When required, strength tests are
         to quantify physical properties are ASTM D 695           conducted at least once when a specific injection
         Test Method for Compressive Properties of Rigid          machine is first used on the job or during the
         Plastics* (Figure 2) and ASTM D 638 Test                 pilot test program. The frequency of the subsequent
         Method for Tensile Properties of Plastics. The           testing should consider the history of the equipment
         compression test is a convenient test because it         and the contractor’s experience and track record.
         utilizes specimens that are easy to make in the
         field to detect discrepancies in the epoxy adhesive.     2.2.2 Field Tests
         Samples of the epoxy adhesive are obtained either
         from the discharge from the mixing head or from          Testing the Mixed Adhesive
         batched epoxy adhesive, and are prepared and             Qualitative epoxy adhesive tests can also provide
         tested in accordance with the applicable ASTM            valuable information when having timely results
         D 695. The tensile test is used less frequently          is essential. Qualitative tests have an advantage
         in the field because the tensile test specimens,         over quantitative tests in that faster results are
         which are cast between glass plates, are more            obtained, reducing the amount of potentially
         *Test Methods cited in this manner are from the American Society for Testing and Materials Annual
         Book of ASTM Standards.
Guide for Verifying field performance of epoxy injection of concrete cracks                                                03734-
          I N T E R N AT I O N A L
          I N S T I T U T E
          defective epoxy adhesive injected. If, during         that which will be used for all the sample testing
          the work, the results indicate noncompliance,         for the project. The color of the epoxy adhesive,
          the work is stopped to identify and correct any       the time to gel, and the ambient temperature (or
          problems prior to continuing the work. Samples        temperature of the adhesive if it is different from
          are labeled to record the location and time when      the ambient) are noted. The standard samples are
          the epoxy adhesive was injected and are retained      marked and retained for color comparison with
          for the specifying authority. Qualitative tests       other samples obtained during the work.
          include a cure rate test and a visual review of the       Injection adhesive tests should be conducted
          prepared material. The gel time test described in     at least once during the first 50 ft (15 m) of crack
          ASTM C 881 Standard—Specification for Epoxy           and thereafter for every 100 ft (30 m) of crack
          Adhesive-Base Bonding Systems for Concrete—           injected. Alternatively, if the work is proceeding
          can be used to confirm that the injected resin will   slowly then tests can be conducted on a time basis
          harden. This test procedure may be modified to        rather than a length basis. In this case a test every
          accelerate the cure by elevating test temperatures.   one to two hours may be appropriate.
          This modification will substantially reduce the
                                                                Testing the Two-component
          time required to obtain test results.
                                                                Injection Equipment
              The important information here is whether         It is extremely important that two-component
          the material will cure, not necessarily how           injection equipment be checked frequently to
          long and at what temperature. This elevated           be sure it is producing properly mixed material
          temperature cure test will identify gross errors     that is of the proper ratio. (Figure 4) The ratio
          in proportioning or mixing, but it will not assure    test is conducted by simultaneously collecting
          that adhesive will cure to its expected physical      each component and comparing the ratio of
          properties at ambient temperature.                    the collected components to the desired ratio.
              A clear container is used in the modified gel     Measurement of the quantity of each component
          time test in order to facilitate observation of the   by weight is more accurate, but collecting the
          material. (Figure 3) The sample is checked for        specimens in transparent graduated containers is
          improper mixing as evidenced by the presence          an acceptable volumetric method. Specimens are
          of streaks, and for improper proportioning as         taken at the beginning of every shift, after any
          evidenced by a difference in color between it         repairs or adjustments are made to the equipment,
          and the standard sample. Prior to initiating the      and any time during a shift when other tests
          work, a standard sample of each batch of adhesive     indicate less than optimum results.
          to used on the job should be established by               The test is conducted under two conditions:
          thoroughly hand mixing 3 oz. (85 g) in the correct    1) with each component flowing freely with no
          ratio. The container should be clear and typical of   external restrictions, and 2) with the flow of each
                           Fig. 3: Gel time test                Fig. 4: Ratio test for
                                                                2 component equipment
03734-                                            Guide for Verifying field performance of epoxy injection of concrete cracks
                                                                                                          I N T E R N AT I O N A L
                                                                                                          I N S T I T U T E
                     Table 1—Field Test Methods and Acceptance Standards
          Test                                          Acceptability Standard
            Ratio Measurement
            Machine mixed epoxy adhesive                  5% of nominal mix ratio unless otherwise
                                                          specified by manufacturer
            Batch mixed epoxy adhesive                    as per manufacturer’s recommendation
            Prepackaged tubes                             as per manufacturer’s recommendation
            Pump Leakage                                  Less than 5 psi (0.034 MPa) drop in 3 minutes
                                                          in either line when stalled at 80% or higher of
                                                          maximum possible discharge pressure
            Cure Rate                                     Measured quantity cures within +/- 10% of
                                                          standard that has been established for same
                                                          quantity prior to commencement of work
            Visual                                        No streaks
                                                          Color compares closely to standard
         component externally restricted to simulate the
         pressure conditions that exist when the adhesive
         is being forced into a crack. The flow restriction
         is achieved by disconnecting the mixing chamber
         and attaching a valve to the end of each fluid line.
         With pump operating, each valve is adjusted until
         the pressure, as measured by a pressure gauge
         in each line, is equal and is at least 80% of the
         maximum possible operating pressure of the
         machine. (Figure 5)
             In addition to the ratio test, a “pressure test”
         is advisable for two-component equipment. When
         used to inject very narrow cracks, injection pumps
         be can be “stalled” with no flow possible so that
         they attempt to pump at high system pressures
         for prolonged periods. These pressures can cause
         internal “leakage” in the metering devices in the
         pumps. To test for this leakage, close each discharge   Fig. 5: Ratio and pressure test schematic
         line at a point beyond the pressure gauges and
         bring the pump system pressure in each discharge        2.3 Removal and Evaluation of Cores from
         line to at least 80% of the maximum discharge           Epoxy Adhesive Injected Concrete
         pressure of which the pump is capable. Observe          Epoxy adhesive injection quality can be assessed
         the pressure in each line for three minutes. If the     by the removal of core samples which include
         pressure falls by more than 5 psi (0.034 MPa) in        the repaired cracks. The samples are extracted
         either line, there is internal leakage and the ratio    by wet or dry core-drilling using a diamond-
         of the two components may not be within the             tipped bit. The contractor should detect rein-
         required acceptance standard when the pump is           forcement or prestressing steel at the designated
         operating at high discharge pressures.                  core locations prior to coring. Scanning the
Guide for Verifying field performance of epoxy injection of concrete cracks                                            03734-
          I N T E R N AT I O N A L
          I N S T I T U T E
          concrete surface with a reinforcement locating         viewed from the exposed length of the crack on
          instrument can reduce the potential for cutting        the sides of the core.
          embedded reinforcement which could result                  A physical test is required to establish the
          in reduction of structural integrity of the            strength of the cured epoxy adhesive and bond
          concrete member.                                       strengths achieved on both sides of the crack.
             The minimum core diameter required for              Physical tests include several methods which
          laboratory (physical) tests is dictated by the test    stress the repair. A simple field test is to manually
          method used. ASTM C 42 Obtaining and Testing           apply a sharp blow with a hammer to the side of
          of Drilled Cores and Sawed Beams of Concrete           the core containing the repaired crack. Other
          requires a minimum diameter twice the size of          methods, which are conducted in a laboratory,
          the large aggregate in the concrete, but recom-        include ASTM C 39 Compression Test of
          mends three times the size for both compressive        Cylindrical Concrete Specimens and ASTM C
          and splitting tensile tests. However, the core         496 Splitting Tensile Strength of Cylindrical
          must have a diameter large enough to contain the       Concrete Specimens. With the splitting tensile
          crack to full depth if the core is to be used for a    test, an attempt should be made to create tension
          splitting tensile strength test. Smaller diameter      perpendicular to the crack plane. (Figure 7) In
          cores of 1 to 2 in. (25 to 50 mm) are adequate         the splitting tension test, tensile stress at the
          when a visual check is being conducted. The            interface is produced by orienting the core on the
          advantage of small diameter cores is that they         testing machine platens so that the bond line is
          are more readily filled and do less damage to the      vertically aligned.
          structure. When practical, the cores should be             Fracture through the parent concrete away
          drilled to the full depth of the repaired crack.       from the repair indicates satisfactory perfor-
             Usually one to two cores taken at random            mance. The presence of shiny or glassy areas on
          locations for every 100 ft (30 m) of injection is      a face of hard cured epoxy adhesive exposed by
          adequate. The specifying authority may increase        the test fracture indicates that the glassy or shiny
          or decrease the number and frequency of core           area cured while exposed to air. From this it can
          samples consistent with the nature of the work         be concluded that the adhesive was in contact with
          and the degree of quality assurance required. All      only one face of the cracked concrete during cure
          requirements for verification cores should be          and there was no effective bond at that location
          clearly defined in the project specifications. Cores   because the crack was not full.
          are usually examined to confirm penetration and            Care must be taken to distinguish between
          apparent set of the adhesive. (Figure 6) Most          failure within the epoxy adhesive and bond
          commonly, penetration is considered adequate           failure between the concrete and epoxy adhesive.
          if 90% of the crack is filled with adhesive, as        If the crack is full of epoxy adhesive of the
Fig. 6: Cores showing epoxy penetration                                        Fig. 7: Splitting tensile test
03734-                                            Guide for Verifying field performance of epoxy injection of concrete cracks
                                                                                                              I N T E R N AT I O N A L
                                                                                                               I N S T I T U T E
       Electronically Generated Pulse by                                               Impact
         Piezoelectric Ceramic Source                                                               Transducer
                                                  Crack                                                      Crack
                                                          T                                         Compression wave              T
                                                                                                Reflecting surface
         Concrete                    Receiver                              Concrete
Fig. 8: Ultrasonic Pulse Velocity (UPV)—Compression              Fig. 9: Impact Echo (IE)—Compression wave reflected
wave blocked/delayed by crack                                    by crack
         proper ratio which has been well mixed, rejecting       the techniques allow for a generalized assessment
         repairs because of poor bond is inappropriate.          inside of a structure which may otherwise appear
         The ability to obtain bond may be beyond the            to have integrity.
         ability of the contractor unless proven otherwise          It is generally recommended that all NDT
         by a pilot test program completed in advance of         methods be used on a “before and after” basis
         starting the repair work. To compare the strengths      for maximum effectiveness and that these
         of the repaired specimen to sound concrete,             investigations be accompanied by some limited
         additional companion cores may be obtained for          coring to verify test results at specific locations.
         sound concrete adjacent to the repairs.                 Non destructivr testing methods are relatively
                                                                 expensive for smaller projects. They require
         2.4 NDT Methods for Quality Assurance of                skilled technicians to conduct the tests and
         Epoxy Adhesive Injection Repairs                        interpret results.
         Nondestructive testing and evaluation (NDT&E)
         with sonic and ultrasonic methods may be used           2.4.1 Ultrasonic Pulse Velocity
         in some circumstances for testing epoxy adhesive        The Ultrasonic Pulse Velocity (UPV) test involves
         injection repairs. Presently there are three sonic      sending a wave energy pulse through the concrete
         NDT methods applicable to epoxy adhesive                from a transmitter to a receiver. The pulse is
         injection quality assurance: Ultrasonic Pulse           generated by an electrical impulse, and the
         Velocity (UPV), Impact Echo (IE), and Spectral          instrument also records the time required for the
         Analysis of Surface Waves (SASW). Of these              pulse to travel from the source to the receiver.
         methods, only UPV has an approved standard              (Figure 8) The UPV test can be performed
         (ASTM C597-83) governing the performance of             from two opposite surfaces (direct test), two non-
         the test. However, this ASTM test was approved          opposite faces (semi-direct test), or the surface
         for general flaw detection and does not specif         of the concrete (indirect test) as illustrated in
         ically address its use for injection quality            Figure 8. Only the direct and semi-direct UPV
         assurance purposes. Sonic NDT methods give              tests are useful for a qualitative assessment of a
         an indication of the relative degree of fill of         repair, unless the repair at the surface of the
         open cracks. They do not measure cure or                concrete is of interest, since the indirect UPV
         bond strength.                                          test only penetrates the near-surface concrete.
             Nondestructive testing methods are generally        When testing is done before and after injection,
         used for structures where large areas must be           the UPV test provides a qualitative indication of
         tested, or when other quality assurance techniques      whether a crack is filled, partially filled, or
         are inadequate. The major advantages of the NDT         comparatively unfilled.
         methods are that, unlike core sampling, no                 Recent research involving cross medium-
         additional damage is done to the structure, and a       medium (direct and angled tests above, below
         close grid of data points can be tested. In addition,   and across an injection zone) to analyze arrival
Guide for Verifying field performance of epoxy injection of concrete cracks                                                03734-
           I N T E R N AT I O N A L
           I N S T I T U T E
                                                                           of surface opening of cracks in concrete elements.
                                       Signal Analyzer
                                                                           IE cannot be used to assess whether an individual
                                                                           crack is only partially filled. The IE method is
                                                                           very effective up to depths of at least one meter.
 Impact/Vibrator             Receiver                    Receiver
    Source                     R1                          R2              2.4.3 Spectral Analysis of Surface Waves
                                                                           A comparatively new NDT method known as the
                                                                           Spectral Analysis of Surface Waves (SASW) has
                                                                           been developed for use on concrete structures.
                                                                           (Figure 10) This method is effective in measuring
                                                                    T      the overall effects of epoxy adhesive injection
                                                                           repair on concrete, particularly when used as a
                                                                           before and after test to compare the condition
                                                                           of the member after the repair to its condition
           Concrete                   Crack
                                                                           before the repair.
                                                                               The SASW method is based upon measuring
Fig. 10: Spectral Analysis of Surface Waves (SASW)—                        surface wave propagation in layered elastic
Crack blocks/delays signal                                                 media. Measurement of the surface wave velocity
                                                                           with the SASW method allows calculation of
                                                                           the estimated compression wave velocity of the
           times can produce a velocity image. Such                        material at various depths between transducers
           velocity tomograms show slow velocity zones                     mounted on the surface. The compression wave
           of the cracking damage before injecting and                     velocity is related to Young’s Modulus, and there-
           an improved, faster velocity tomogram after                     fore the relative condition of the concrete at
           successful injection.                                           various depths between the receivers can be
                                                                           evaluated. Repeated tests at various locations can
           2.4.2 Impact Echo Test Method                                   give the condition versus location throughout the
           In the Impact Echo (IE) test the surface is                     structure at various depths.
           impacted by mechanical means with a small                           Like the IE method, the SASW method
           impactor which produces stress waves as shown                   requires access to only one side of a structure.
           in Figure 9. These stress waves propagate through               The SASW test is only effective in measuring
           and along the element being tested. Once the                    the overall average condition of the member,
           traveling waves encounter a discontinuity, a                    based on stiffness and lateral wave propagation.
           portion of the wave energy reflects back to the                 It cannot be used to determine the fill or strength
           test surface. Unfilled or partially filled cracks               of a particular crack unless there is only one crack
           would be an example of such a discontinuity.                    between the pair of receivers. If closely spaced
           The reflected stress wave energy, or “echo,” is                 0.15 m (0.50 ft.) SASW tests are conducted,
           monitored by a receiver placed on the concrete                  one can obtain a simple tonogram, or image,
           surface. Since both the source and the receiver                 of the variation of velocity vs. wave length into
           are placed on the concrete surface, only one                    the concrete.
           surface, unlike the UPV method, needs to be
           accessible for testing of a concrete element. Like              Cited References
           UPV, impact echo used in this manner can only                   ASTM (Annual)
           be used “qualitatively” to assess the effectiveness             Annual Book of ASTM Standards
           of epoxy adhesive injection.                                    American Society for Testing and Materials
              The IE method, using a systems of two trans-                 100 Barr Harbor Drive
           ducers, can be effective in determining the depths              West Conshohocken, PA 19428-2959.
03734-10                                                      Guide for Verifying field performance of epoxy injection of concrete cracks
I N T E R N AT I O N A L
I N S T I T U T E
1323 Shepard Drive, Suite D
Sterling, VA 20164-4428
Phone 703-450-0116
Fax 703-450-0119
E-mail: mcollins@icri.org