0% found this document useful (0 votes)
91 views2 pages

Novotest T-D3

The Leeb method is the most popular portable method for testing metal hardness using a Leeb hardness tester. The tester uses a dynamic method that is easy to use as it requires no special skills - the user simply charges the probe, places it on the surface, presses a button and the hardness value is displayed. This method can test both large and small metal parts. The Leeb hardness tester measures hardness scales for steel and other metals and allows for custom calibrations and additional languages.

Uploaded by

Sam Adam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
91 views2 pages

Novotest T-D3

The Leeb method is the most popular portable method for testing metal hardness using a Leeb hardness tester. The tester uses a dynamic method that is easy to use as it requires no special skills - the user simply charges the probe, places it on the surface, presses a button and the hardness value is displayed. This method can test both large and small metal parts. The Leeb hardness tester measures hardness scales for steel and other metals and allows for custom calibrations and additional languages.

Uploaded by

Sam Adam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Leeb Hardness Tester NOVOTEST T-D3

The most popular method in the world for testing the hardness of metals using a portable
hardness tester is the Leeb method (ASTM A956).
The so-called dynamic method for determining hardness is widespread due to its ease of use.
The user does not need to have special skills and or knowledge in the field of hardness
measurement, to carry out the measurement, it is necessary to charge up the impact body of
the device’s probe, install the probe on the tested surface, press the release button of the
probe and the hardness value will be displayed on the device screen.
This method is recommended for large products, weighing from 5 kg and a thickness of 10 mm
and more, however, observing certain requirements for fixing the product, it is possible to
measure also small parts.

o D
o DC
o DL
Probe types o C
o D+15
o E
o G
o HRC:20~70
o HB:90~650
o HV:230~940
Measuring range for steel
o HLD:170~960
o Tensile strength, MPa: 370~1740
o User calibrations for any range (for example: HV100-1600)
o HRC: 2HRC
o HB: 10HB
Measuring accuracy
o HV: 15HV
o HLD: 4HLD
o ASTM A 956
o ASTM E 140
o ASTM A 370
o ISO 16859
Standards
o DIN 50156
o GB/T 17394
o JB/T 9378
o ISO 18265

Indenter Hardened ball (Leeb)


Measuring direction Any direction 360°

Data storage Limited only by the memory card up to 32Gb

Upload data to PC and export as a spreadsheet (USB cable and


Communication
software included )

o Leeb probe – HRC, HRB, HB, HV, HL, MPa


Hardness scale
o Additional custom scales for calibration

o Dynamic (Leeb) pre-calibrated for steel, alloy steel, cast


Materials iron, stainless steel, aluminum, bronze, brass, copper
o Additional custom materials for calibration
o Angle (Leeb)
o Single test result
o Max, Min, Average of tests
o Number of tests
Data display
o Deviation
o Var. coeff.
o Histogram
o Signal and Smart Mode (Filter of incorrect measurements)
o English
o German
o French
Language
o Polish
o Russian
*additional languages available by request

Indication Color LCD display (320×240)

o Temperature: -20°C~40°C
Operating environment
o Humidity: 30%~80%R.H.

Power supply DC 4,5V (3 pcs batteries AA)

Instrument dimensions 160x75x30mm

Net weight Approx. 0.3kg (Without probe)

Battery life Approx. 10 hours.