Cat 330 BL

Two new relief valves were added to the main control valve on several excavator models to improve the smoothness of swing operations. The 147-4163 and 147-4161 Relief Valve Groups replaced older valves in the 107-7011 and 107-7014 Control Valve Groups, which are components of the 107-7010 Test Valve Group. The changes decrease negative control pressure during initial swing movement. Illustrations show the locations of the control valve groups and new relief valves.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views3 pages

Cat 330 BL

Two new relief valves were added to the main control valve on several excavator models to improve the smoothness of swing operations. The 147-4163 and 147-4161 Relief Valve Groups replaced older valves in the 107-7011 and 107-7014 Control Valve Groups, which are components of the 107-7010 Test Valve Group. The changes decrease negative control pressure during initial swing movement. Illustrations show the locations of the control valve groups and new relief valves.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Service Information System Page 1 of 3

Service Magazine
Media Number -SEPD0414-00 Publication Date -27/04/1998 Date Updated -27/04/1998

SEPD04140007

New Relief Valves In Main Control Valve Improve Swing


Operation {5051,5454}
SMCS - 5051; 5454

330B (9HN, 8SR),


330B L (2RR, 3YR, 6DR, 8TR, 1JS, 4RS, 5LS),
330B LN (5LR) Excavators

Description of Change: Two new relief valves in the main control valve are used to decrease
negative control pressure. The lower pressure produces a smoother movement during the initiation of
the swing operation.

Adaptable To: The new 147-4163 Relief Valve Group is used in place of the former 109-5152
Relief Valve Group in the 107-7011 Control Valve Group.

The new 147-4161 Relief Valve Group is used in place of the former 109-2667 Relief Valve Group
in the 107-7014 Control Valve Group.

The control valve groups listed are components in the 107-7010 Test Valve Group. The test valve
group that utilizes the new relief valves is effective with 330B L (3YR490-Up, 6DR1547-Up,
4RS650-Up, 5LS205-Up) and 330B LN (5LR297-Up) Excavators. The effective serial number of the
test valve group is 1450-Up for 330B L (6DR) Excavators.

Illustration 1 shows the location of the control valve groups in a unit test valve group. Illustrations 2
and 3 detail the location of the new relief valve groups in a control valve group.

View Image

https://127.0.0.1:447/sisweb/sisweb/techdoc/content.jsp?calledpage=/sisweb/sisweb/p... 23/01/2024
Service Information System Page 2 of 3

Illustration 1.
107-7010 Unit Test Valve Group.

(1) 107-7011 Control Valve Group.


(2) 107-7014 Control Valve Group.

View Image

Illustration 2.
Section A-A from Illustration 1 and Detail C.

https://127.0.0.1:447/sisweb/sisweb/techdoc/content.jsp?calledpage=/sisweb/sisweb/p... 23/01/2024
Service Information System Page 3 of 3

(3) 147-4163 Relief Valve Group.


(4) 147-4164 Valve Body (not serviced).

View Image

Illustration 3.
Section B-B from Illustration 1 and Detail D.

(5) 147-4161 Relief Valve Group.


(6) 147-4162 Valve Body (not serviced).

Copyright 1993 - 2024 Caterpillar Inc. Tue Jan 23 23:31:19 EST 2024