LC1D25M7

This 3-sentence summary provides the key details about the LC1D25M7 contactor product datasheet: The LC1D25M7 contactor has a rated operational current of 25A at voltages up to 440V AC, is designed for motor control and resistive load applications up to 11kW, and contains specifications for its voltage ratings, mounting options, standards compliance, and terminal connection sizes and types.

Uploaded by

Feryan Al Fatha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views3 pages

LC1D25M7

This 3-sentence summary provides the key details about the LC1D25M7 contactor product datasheet: The LC1D25M7 contactor has a rated operational current of 25A at voltages up to 440V AC, is designed for motor control and resistive load applications up to 11kW, and contains specifications for its voltage ratings, mounting options, standards compliance, and terminal connection sizes and types.

Uploaded by

Feryan Al Fatha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Product datasheet LC1D25M7

Characteristics

Main
Range TeSys
Product name TeSys D
Product or component type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-1
AC-3
AC-4
Poles description 3P
Pole contact composition 3 NO
System Voltage <= 690 V AC 25...400 Hz power circuit

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
<= 300 V DC power circuit
[Ie] rated operational current 25 A (<= 140 °F (60 °C)) at <= 440 V AC AC-3
power circuit
40 A (<= 140 °F (60 °C)) at <= 440 V AC AC-1
power circuit
Motor power kW 11 kW at 380...400 V AC 50/60 Hz AC-3
15 kW at 500 V AC 50/60 Hz AC-3
15 kW at 660...690 V AC 50/60 Hz AC-3
5.5 kW at 220...230 V AC 50/60 Hz AC-3

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
11 kW at 415...440 V AC 50/60 Hz AC-3

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
5.5 kW at 400 V AC 50/60 Hz AC-4
Motor power hp 2 hp at 115 V AC 50/60 Hz 1 phase motors
7.5 hp at 200/208 V AC 50/60 Hz 3 phases motors
3 hp at 230/240 V AC 50/60 Hz 1 phase motors
7.5 hp at 230/240 V AC 50/60 Hz 3 phases motors
15 hp at 460/480 V AC 50/60 Hz 3 phases motors
20 hp at 575/600 V AC 50/60 Hz 3 phases motors
Control circuit type AC 50/60 Hz
[Uc] control circuit voltage 220 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand 6 kV conforming to IEC 60947
voltage
Overvoltage category III
[Ith] conventional free air thermal 40 A at <= 140 °F (60 °C) power circuit
current 10 A at <= 140 °F (60 °C) signalling circuit
Irms rated making capacity 450 A at 440 V power circuit conforming to IEC
60947
140 A AC signalling circuit conforming to IEC
60947-5-1
250 A DC signalling circuit conforming to IEC
60947-5-1
Rated breaking capacity 450 A at 440 V power circuit conforming to IEC
60947
[Icw] rated short-time withstand 120 A <= 104 °F (40 °C) 1 min power circuit
current 240 A <= 104 °F (40 °C) 10 s power circuit
380 A <= 104 °F (40 °C) 1 s power circuit
50 A <= 104 °F (40 °C) 10 min power circuit
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
Associated fuse rating 40 A gG at <= 690 V coordination type 2 power
circuit
63 A gG at <= 690 V coordination type 1 power
circuit
10 A gG signalling circuit conforming to IEC
60947-5-1

1/4
Average impedance 2 mOhm at 50 Hz - Ith 40 A power circuit
[Ui] rated insulation voltage 600 V power circuit certifications CSA
600 V power circuit certifications UL
690 V power circuit conforming to IEC 60947-4-1
690 V signalling circuit conforming to IEC 60947-1
600 V signalling circuit certifications CSA
600 V signalling circuit certifications UL
Electrical durability 1.65 Mcycles 25 A AC-3 at Ue <= 440 V
1.4 Mcycles 40 A AC-1 at Ue <= 440 V
Power dissipation per pole 3.2 W AC-1
1.25 W AC-3
Protective cover With
Mounting support Plate
Rail
Standards UL 508
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
Product certifications BV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
RINA
UL
Connections - terminals Control circuit: screw clamp terminals 2 cable(s)
0...0 in² (1...2.5 mm²) - cable stiffness: flexible -
with cable end
Power circuit: screw clamp terminals 1 cable(s)
0...0.02 in² (1.5...10 mm²) - cable stiffness: solid -
without cable end
Control circuit: screw clamp terminals 1 cable(s)
0...0.01 in² (1...4 mm²) - cable stiffness: flexible -
without cable end
Control circuit: screw clamp terminals 2 cable(s)
0...0.01 in² (1...4 mm²) - cable stiffness: flexible -
without cable end
Control circuit: screw clamp terminals 1 cable(s)
0...0.01 in² (1...4 mm²) - cable stiffness: flexible -
with cable end
Control circuit: screw clamp terminals 1 cable(s)
0...0.01 in² (1...4 mm²) - cable stiffness: solid -
without cable end
Control circuit: screw clamp terminals 2 cable(s)
0...0.01 in² (1...4 mm²) - cable stiffness: solid -
without cable end
Power circuit: screw clamp terminals 1 cable(s)
0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible
- without cable end
Power circuit: screw clamp terminals 2 cable(s)
0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible
- without cable end
Power circuit: screw clamp terminals 1 cable(s)
0...0.02 in² (1...10 mm²) - cable stiffness: flexible -
with cable end
Power circuit: screw clamp terminals 2 cable(s)
0...0.01 in² (1.5...6 mm²) - cable stiffness: flexible -
with cable end
Power circuit: screw clamp terminals 2 cable(s)
0...0.02 in² (2.5...10 mm²) - cable stiffness: solid -
without cable end
Tightening torque Control circuit: 15.04 lbf.in (1.7 N.m) - on screw
clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 15.04 lbf.in (1.7 N.m) - on screw
clamp terminals - with screwdriver Philips No 2
Power circuit: 22.12 lbf.in (2.5 N.m) - on screw
clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 22.12 lbf.in (2.5 N.m) - on screw
clamp terminals - with screwdriver Philips No 2
Operating time 4...19 ms opening
12...22 ms closing

2/4
Safety reliability level B10d = 1369863 cycles contactor with nominal
load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with
mechanical load conforming to EN/ISO 13849-1
Mechanical durability 15 Mcycles
Operating rate 3600 cyc/h at <= 140 °F (60 °C)

Complementary
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3...0.6 Uc drop-out at 140 °F (60 °C), AC 50/60 Hz
0.8...1.1 Uc operational at 140 °F (60 °C), AC 50 Hz
0.85...1.1 Uc operational at 140 °F (60 °C), AC 60 Hz
Inrush power in VA 70 VA at 68 °F (20 °C) (cos ϕ 0.75) 60 Hz
70 VA at 68 °F (20 °C) (cos ϕ 0.75) 50 Hz
Hold-in power consumption in VA 7.5 VA at 68 °F (20 °C) (cos ϕ 0.3) 60 Hz
7 VA at 68 °F (20 °C) (cos ϕ 0.3) 50 Hz
Heat dissipation 2...3 W at 50/60 Hz
Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA signalling circuit
Minimum switching voltage 17 V signalling circuit
Non-overlap time 1.5 ms on energisation between NC and NO contact
1.5 ms on de-energisation between NC and NO contact
Insulation resistance > 10 MOhm signalling circuit

Environment
IP degree of protection IP20 front face conforming to IEC 60529
protective treatment TH conforming to IEC 60068-2-30
pollution degree 3
ambient air temperature for operation 23...140 °F (-5...60 °C)
ambient air temperature for storage -76...176 °F (-60...80 °C)
permissible ambient air temperature around the device -40...158 °F (-40...70 °C) at Uc
operating altitude 9842.52 ft (3000 m) without derating in temperature
fire resistance 1562 °F (850 °C) conforming to IEC 60695-2-1
flame retardance V1 conforming to UL 94
mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz
Vibrations contactor closed 4 Gn, 5...300 Hz
Shocks contactor closed 15 Gn for 11 ms
Shocks contactor open 8 Gn for 11 ms
height 3.35 in (85 mm)
width 1.77 in (45 mm)
depth 3.62 in (92 mm)
product weight 0.82 lb(US) (0.37 kg)

Offer Sustainability
Green Premium product Green Premium product
Compliant - since 0627 - Schneider Electric declaration Compliant - since 0627 - Schneider Electric declaration of conformity
of conformity
Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold
Available Available
Available Available
WARNING: This product can expose you to chemicals WARNING: This product can expose you to chemicals including:
including:
Antimony oxide & Antimony trioxide, which is known to Antimony oxide & Antimony trioxide, which is known to the State of California to cause
the State of California to cause cancer. cancer.
For more information go to www.p65warnings.ca.gov For more information go to www.p65warnings.ca.gov