CT 155069
CT 155069
Product Guide
• XT Manual Motor Protectors
• XT Manual Motor Controllers
Global products
mean global
solutions
Eaton’s Electrical operations
As a market-leading manufacturer of circuit protection and control equipment, Eaton’s world leading switch
and fuse-gear, circuit breakers, motor control gear and wiring accessory products are distributed across the
globe. Incorporating the latest technological advances, Eaton products are the result of a comprehensive
ongoing development programme and comply with the industry’s most rigorous quality standards. This all
serves to make Eaton an industry benchmark, with unsurpassed quality and performance guaranteed. This
extensive product range, together with a lengthy experience and specialist knowledge serves to make Eaton
your first source solutions provider.
Services Portfolio
Extensive support services
Our service strategy includes an extensive selection of
technical and commercial services designed to help you
specify, order and receive products quickly and efficiently.
World-Class Support
Price & Availability Project Co-Ordination
• Prompt Product Pricing • Order tracking for
At Eaton, our goal is to deliver • Up-to-date stock Systems based orders
world-class support as well as availability • On-site Project
Management service
products. Order & Shipment status • Tailored Delivery service
This is why we continue to invest in our customer service • Order Checking and
capability to ensure you have easy access to the services Status Engineered Site Services
you need, when you need them. • Shipment details • Installation and
Commissioning
Technical Support • Maintenance and
Integrated service strategy • “Over the phone” Service Solution support
Our integrated service strategy is based upon linking key resolution • 24 hour “call out”
locations and personnel along with a complete range of • Technical data emergency service
services to provide you “one-call” customer service. assistance
A central support number allows you to access these • Selection and cross- Distributor Product
support services by selecting the product group and service reference Training
required. We then ensure it is quickly routed to a qualified • Individual or Group
support agent. The result is service that delivers you After Sales Support Product training forums
solutions … fast. • Debit/Credit note • Use of “In house”
A single point of contact for all your enquiries is just one of resolution training facilities
the benefits you can look forward to as an Eaton customer. • Policy Returns support
How to use this Product Guide
STEP 1
Choose main group
STEP 2
Choose list number
Indexes
Search by product name or list number.
Legend
Function of coloured text bars:
Products
Accessories
This chapter describes general characteristics of Eaton’s technologically advanced range of Relays and
Timers, Miniature Controls, Contactors , Overload Relays, Starters Manual Motor Protectors and Manual
Motor Controllers.
Because XT meets IEC, UL, CSA, and CCC standards, it is the perfect product solution for applications all
over the world.
Eaton’s new line of XT Relays and Timers includes miniature and standard frame control relays and
auxiliary contacts, miniature electronic on-delay and multi-function timers and an electronic star-delta
timer for use in star-delta combinations.
Technical characteristics
• For use with Miniature and Standard frame size contactors and
starters
• Control Relays
• AC Control from 12V to 550V 50 Hz, 600V 60 Hz
• DC Control from 12V to 220V
• On-Delay and Multi-FunctionTimers
• 24 – 240V AC/DC Control
• Available with screw or spring cage terminals
• 4-Pole Configurations
• IP20 finger and back-of-hand proof
•Large ambient temperature range – 25° to 50°C
Standards
• IEC EN 60947
• CE Marked
• UL
• CSA
• CCC (pending)
• ATEX (pending)
Technical characteristics
Technical Characteristics
• AC control from 12V to 600V
50/60 Hz
• DC control from 12V to 220V
• Available with screw or spring cage terminals
G ener al char act er i st i cs, Pr oduct s
Technical Characteristics
• ON/OFF Rotary Handle with Lockout Provision
• Visible Trip Indication
• Class 10 Overload Protection
• Phase Loss Sensitivity
Types (Configurations)
• Motor Protective Device with Thermal and Magnetic Trip
- XTPB Pushbutton Actuated Manual Motor Protector up to 25A
- XTPR Rotary Actuated Manual Motor Protector up to 63A
• For the Protection of Transformers with a high inrush current:
- XTPT Manual Transformer Protector up to 25A
• Motor Protective Device without Overload Function:
- XTPM Motor Protective Circuit Breaker up to 32A — not UL
Approved
Features
• ON/OFF rotary handle with lockout provision
• Visible trip indication
• Test trip function
• Motor applications from 0.11A to 50A
• Class 10 overload protection
• Built-in heater and magnetic trip
elements to protect the motor
• Phase loss sensitivity
• Type 2 coordination
• Ambient compensated up to 55°C
• Control inputs located at front of starter for easy access and
wiring
• Wide range of coils
• DIN Rail mount — XTSC…BB_
• Mounting plates — XTSC…BC_, XTSC…D motor controllers
• Adjustment dial for setting motor FLC
• Short circuit trip at 14 times the maximum setting of the FLC
adjustment dial
• 1NO-1NC Auxiliary Contact as
standard on Manual Motor Protector
Standards
• IEC EN 60947
• CE Marked
• UL
• CSA
• CCC
• ATEX
R elays and Ti m er s
See page 10 for coil suffix.
See page 10 for accessories.
See page 78 for dimensional drawings
See page 81 for the technical details.
XTRM10A22A
10 4NO 6 3 A1 13 23 33 43 XTRM10A40_ XTRMC10A40_
A2 14 24 34 44
10 3NO-1NC 6 3 A1 13 21 33 43 XTRM10A31_ XTRMC10A31_
A2 14 22 34 44
10 2NO-2NC 6 3 A1 13 21 31 43 XTRM10A22_ XTRMC10A22_
A2 14 22 32 44
1) Underscore (_) indicates coil suffix required.
Eaton Eaton
list number 1) list number 1)
A2 14 24 34 44
10 3NO-1NC 6 4 A1 13 21 33 43 XTRE10B31_ XTREC10B31_
A2 14 22 34 44
10 2NO-2NC 6 4 A1 13 21 31 43 XTRE10B22_ XTREC10B22_
A2 14 22 32 44
1) Underscore (_) indicates coil suffix required.
110V 120V A
220V 240V B
230V F
24V 24V T
415V 480V C
550V 600V D
208V E
190V 220V G
240V 277V H
380V 440V L
400V N
380V P
12V 12V R
24V U
42V 48V W
R elays and Ti m er s
48V Y
120V AD 2)
220V BD 2)
12V RD 2)
24V TD 2)
48V WD 2)
1) Add suffix in place of underscore (_) to Eaton List Number
2) With DC Operation: Integrated diode-resistor combination, coil consumption 2.6 kW.
Front Mount Auxiliary Contacts for use with XTRM Miniature Control Relays
Conventional Poles Contact Contact Symbol QPC Terminals
Free Air Configuration
Thermal current, Screw Spring Cage
I th = I e ,
AC-1 in Amps Eaton Eaton
list number list number
10 2 2NC 5 XTMCXFA02 —
51 61
XTMCXFA02
52 62
10 2 1NO-1NC 5 XTMCXFA11 XTMCXFAC11
53 61
54 62
10 2 2NO-0NC 5 XTMCXFA20 —
53 63
54 64
10 2 1NO-1NC 5 XTMCXFAL111) —
57 65
58 66
10 4 4NC 5 XTMCXFA04 XTMCXFAC04
51 61 71 81
52 62 72 82
10 4 1NO-3NC 5 XTMCXFA13 XTMCXFAC13
53 61 71 81
54 62 72 82
10 4 2NO-2NC 5 XTMCXFA22 XTMXCFAC22
53 61 71 83
54 62 72 84
10 4 3NO-1NC 5 XTMCXFA31 XTMCXFAC31
53 61 73 83
54 62 74 84
10 4 4NO-0NC 5 XTMCXFA40 XTMCXFAC40
53 63 73 83
54 64 74 84
10 4 2NO-2NC 5 XTMCXFAL221) XTMCXFCLC221)
57 65 71 83
58 66 72 84
1) 1 early-make contact, 1 late-break contact.
54 64
16 2 1NO-1NC 5 XTCEXFAC11 XTCEXFACC11
53 61
54 62
16 2 2NC 5 XTCEXFAC02 XTCEXFACC02
51 61
52 62
16 2 1NO-1NC 57 65 5 XTCEXFALC111) XTCEXFALCC11 1)
58 66
16 4 4NO 5 XTCEXFAC40 XTCEXFACC40
R elays and Ti m er s
53 6373 83
54 6474 84
16 4 3NO-1NC 53 61 73 83 5 XTCEXFAC31 XTCEXFACC31
54 62 74 84
16 4 2NO-2NC 5 XTCEXFAC22 XTCEXFACC22
5361 71 83
54 62 72 84
16 4 1NO-3NC 5 XTCEXFAC13 XTCEXFACC13
536171 81
54 62 72 82
16 4 4NC 51 61 71 81 5 XTCEXFAC04 XTCEXFACC04
52 62 72 82
16 4 2NO-2NC 5 XTCEXFCLC22 1) XTCEXFCLCC22 1)
5765 71 83
58 66 72 84
1) 1 early-make contact, 1 late-break contact.
On-Delayed
24V AC/DC 0.05 s - 1s XTRE10B_ 1 XTCEXTEEC11T
100 - 130V AC 0.5s - 10s XTCEXTEEC11T
200 - 240V AC 5s - 100s XTCEXTEEC11T
Off-Delayed
24V AC/DC 0.05 s - 1s XTRE10B_ 1 XTCEXTED1C11T
100 - 130V AC XTCEXTED1C11A
200 - 240V AC XTCEXTED1C11B
24V AC/DC 0.5s - 10s XTRE10B_ 1 XTCEXTED10C11T
100 - 130V AC XTCEXTED10C11A
200 - 240V AC XTCEXTED10C11B
24V AC/DC 5s - 100s XTRE10B_ 1 XTCEXTED100C11T
100 - 130V AC XTCEXTED100C11A
200 - 240V AC XTCEXTED100C11B
Star-Delta
24V AC/DC 1s - 30s XTRE10B_ 1 XTCEXTEYC20T
100 - 130V AC XTCEXTEYC20A
200 - 240V AC XTCEXTEYC20B
Sealable Shroud
Transparent sealable shroud XTCEXTEE 1 XTCEXTESHRD
used to protect electronic XTCEXTED
timer modules from unwanted XTCEXTEY
access.
Actuating Voltage Conventional Rated Operational Current Time Selectable Circuit Symbol Eaton
Thermal I e AC-11 Amps Range Function list number
Current 220/230/240V 380/400/440V Selection
I e (A)
XTMT6A30S11B
24-240V 50/60Hz 6 3 3 1.5 – 30 sec Fixed, A1 15 XTMT6A30S11B
24-240V DC .05 – 1 sec On-delay
0.15 – 3 sec
0.5 – 10 sec A2 16 18
3 – 60 sec
24-240V 50/60Hz 6 3 6 0.15 – 3 min Fixed, A1 15 XTMT6A60H11B
24-240V DC 0.5 – 10 min On-delay
3 – 60 min
0.15 – 3 h A2 16 18
0.5 – 10 h
3 – 60 h
R elays and Ti m er s
Actuating Voltage Conventional Rated Operational Current Time Selectable Circuit Symbol Eaton
Thermal I e AC-11 Amps Range Function list number
Current 220/230/240V 380/400/440V Selection
I e (A)
Electronic Star-Delta
• Fixed Star-Delta
Actuating Conventional Rated Operational Current Time Selectable Circuit Symbol Eaton
Voltage Thermal I e AC-11 Amps Range Function list number
Current Selection
I e (A) 230V 400V
XTTR6A60551B
24-240V 6 3 3 3 – 60 Fixed, Star- XTTR6A60S51B
17
50/60Hz sec Delta A1
24-240V DC
A2 18 28
Standards
• IEC EN 60947
• CE Marked
• UL
• CSA
• CCC
• ATEX
M iniatur e C ontr ol s
Miniature Contactors
Operational Conventional Maximum No. of Auxiliary Circuit Terminals
Current AC-3 Free Air kW Ratings AC-3 Power Contacts Symbol
Amp Rating Thermal Current 3-Phase Motors Poles Screw Spring Cage
380/400V AC-1 at 50°C 50 – 60Hz
220 – 380 – 550V 660/ Eaton Eaton
240V 400V 690V list number 1) list number 1)
XTMC9A01A
6.6 20 1.5 3 3 3 3 1NO XTMC6A10_ XTMCC6A1_
A1 1 3 5 13
A2 2 4 6 14
6.6 20 1.5 3 3 3 3 1NC A1 1 3 5 21 XTMC6A01_ XTMCC6A0_
A2 2 4 6 22
8.8 20 2.2 4 4 4 3 1NO A1 1 3 5 13 XTMC9A10_ XTMCC9A1_
A2 2 4 6 14
8.8 20 2.2 4 4 4 3 1NC A1 1 3 5 21 XTMC9A01_ XTMCC9A0_
A2 2 4 6 22
8.8 20 2.2 4 4 4 4 — A1 1 3 5 7 XTMF9A00_ —
A2 2 4 6 8
1) Underscore (_) indicates Coil Suffix required.
Coil Suffix
M iniatur e C ontr ol s
110V 120V A
220V 240V B
230V F
24V 24V T
415V 480V C
550V 600V D
208V E
190V 220V G
240V 277V H
380V 440V L
400V N
380V P
12V 12V R
24V U
42V 48V W
48V Y
120V AD 2)
220V BD 2)
12V RD 2)
24V TD 2)
48V WD 2)
1) Add suffix in place of underscore (_) to Eaton List Number.
2) With DC Operation: Integrated diode-resistor combination, coil consumption 2.6 kW.
Eaton Eaton
list number list number
10 2 5 XTMCXFC02 —
21 31
22 32
10 2 1NO-1NC 5 XTMCXFD11 XTMCXFDC11
21 33
22 34
10 4 2NO-2NC 5 XTMCXFC22 XTMCXFCC22
21 31 43 53
22 32 44 54
10 2 2NC 5 XTMCXFA02 —
51 61
M iniatur e C ontr ol s
52 62
10 2 1NO-1NC 5 XTMCXFA11 XTMCXFAC11
53 61
54 62
10 2 2NO-0NC 5 XTMCXFA20 —
53 63
54 64
10 2 1NO-1NC 5 XTMCXFAL111) —
57 65
58 66
10 4 4NC 5 XTMCXFA04 XTMCXFAC04
51 61 71 81
52 62 72 82
10 4 1NO-3NC 5 XTMCXFA13 XTMCXFAC13
53 61 71 81
54 62 72 82
10 4 2NO-2NC 5 XTMCXFA22 XTMXCFAC22
53 61 71 83
54 62 72 84
10 4 3NO-1NC 5 XTMCXFA31 XTMCXFAC31
53 61 73 83
54 62 74 84
10 4 4NO 5 XTMCXFA40 XTMCXFAC40
53 63 73 83
54 64 74 84
10 4 2NO-2NC 5 XTMCXFAL221) XTMCXFCLC221)
57 65 71 83
58 66 72 84
1) 1 early make, 1 late break.
Varistor Suppressor
• For AC operated contactors, 50/60 Hz. DC operated contactors have integrated varistor suppressors.
24 – 48 XTMC6A…, XTMC9A… A1
10 XTMCXVSW
48 – 130 XTMC6A…, XTMC9A… 10 XTMCXVSA
M iniatur e C ontr ol s
XTMCXSDB
XTMCXSDL
XTMCXPLK
M iniatur e C ontr ol s
XTMCXRL
Mechanical Interlock
• For two contactors with AC or DC operated magnet system that are horizontally mounted, the distance
between contactors is 0 mm, and the mechanical lifespan is 2.5 x 106 operations.
XTMCXML
Connector
• 0 mm distance between contactors.
XTMCXCN
XTMCXSHROUD
Overload Trip Contact Circuit Short Circuit Protection (A) Eaton list
Release It Class Configuration Symbol Type 1 Type 2 Circuit number
Coordination, Coordination, Breaker
XTOMO12AC1 gG/gL gG/gL
Standards
• IEC EN 60947
• CE Marked
• UL
• CSA
• CCC
• ATEX
XTCE007810B
7 20 2.2 3 4 3.5 — 1NO XTCE007B10_
7 20 2.2 3 4 3.5 — 1NC XTCE007B01_
9 20 2.5 4 5.5 4.5 — 1NO XTCE009B10_
9 20 2.5 4 5.5 4.5 — 1NC XTCE009B01_
12 20 3.5 5.5 7 6.5 — 1NO XTCE012B10_
12 20 3.5 5.5 7 6.5 — 1NC XTCE012B01_
15.5 20 4 7.5 8 7 — 1NO XTCE015B10_
15.5 20 4 7.5 8 7 — 1NC XTCE015B01_
1) Underscore (_) indicates coil suffix required.
2) 7 – 150A DC operated contactors have an integrated suppressor.
3) For Spring Cage Terminals, insert C after the fourth digit of the Eaton list number. Example: XTCEC007B10A. For 7 – 15A XTCEC Contactors, the
power, auxiliary and coil terminals are spring cage.
XTCE018C10B
18 35 5 7.5 10 11 — 1NO XTCE018C10_
18 35 5 7.5 10 11 — 1NC XTCE018C01_
25 40 7.5 11 14.5 14 — 1NO XTCE025C10_
25 40 7.5 11 14.5 14 — 1NC XTCE025C01_
32 40 10 15 18 17 — 1NO XTCE032C10_
32 40 10 15 18 17 — 1NC XTCE032C01_
1) Underscore (_) indicates coil suffix required.
2) 7 – 150A DC operated contactors have an integrated suppressor.
3) For Spring Cage Terminals, insert C after the fourth digit of the Eaton list number. Example: XTCEC007B10A. For 18 – 32A XTCEC Contactors,
the auxiliary and coil terminals are spring cage.
XTCE080F00B 80 90 25 37 48 63 45 — XTCE080F00_
95 110 30 45 57 75 55 — XTCE095F00_
1) Underscore (_) indicates coil suffix required.
2) 7 – 150A DC operated contactors have an integrated suppressor.
3) For Spring Cage Terminals, insert C after the fourth digit of the Eaton list number. Example: XTCEC007B10A. For 40 – 150A XTCEC Contactors,
C on tacto rs and O ver load R elays
XTCE580N22B
XTCE580N22_
580 800 185 315 348 560 600 2NO-2NC
XTCE650N22_
650 850 205 355 390 630 600 2NO-2NC
750 900 240 400 455 720 800 2NO-2NC XTCE750N22_
820 1000 260 450 500 750 800 2NO-2NC XTCE820N22_
1000 1000 315 560 610 1000 1000 2NO-2NC XTCEC10N22_
1) Underscore (_) indicates coil suffix required.
2) 185 – 2000A AC and DC contactors have an integrated suppressor.
XTCEC14P22B
— 1400 3) — — — — — 2NO-2NC XTCEC14P22_
1) Underscore (_) indicates coil suffix required.
2) When operating the 580 – 2000A XTCE contactors with frequency inverters, the suppressor on the load side must be removed. The load side
suppressor must also be removed when performing a high-voltage test.
3) AC-1 Ratings Only.
4) For 185 – 2000A Contactors at 660/690V or 1000V: Do not reverse directly.
XTCEC20R22
— 2000 3) — — — — — 2NO-2NC XTCEC20R22_
1) Underscore (_) indicates coil suffix required.
2) When operating the 580 – 2000A XTCE contactors with frequency inverters, the suppressor on the load side must be removed. The load side
suppressor must also be removed when performing a high-voltage test.
3) AC-1 Ratings Only.
63 63 XTCR007B21_
7 2.2 3 4 3.5 64 64
63 63 XTCR009B21_
9 2.5 4 5.5 4.5 64 64
63 63 XTCR012B21_
12 3.5 5.5 7 6.5 64 64
1)Underscore (_) indicatest coil suffix required.
63 63 XTCR018C21_
18 5 7.5 8 11 64 64
63 63 XTCR025C21_
25 7.5 11 14.5 14 64 64
63 63 XTCR032C21_
32 10 15 18 17 64 64
1)Underscore (_) indicates coil suffix required.
XTCR065D11
I e (A) Maximum kW Ratings AC-3 Spare Auxiliary Eaton list
Contacts number 1)
AC-3 3-Phase Motors 50 – 60 Hz K1M K2M
220/ 380/ 415V 660/
230V 400V 690V
80 25 37 48 63 XTCR080F11_
95 30 45 57 75 XTCR095F11_
1)Underscore (_) indicates coil suffix required.
115 37 55 70 90 XTCR115G11_
150 48 75 91 96 XTCR150G11_
1)Underscore (_) indicates coil suffix required.
54 62
16 2 2NC 51 61 5 XTCEXFAC02 XTCEXFACC02
52 62
16 2 1NO-1NC 57 65 5 XTCEXFALC11 1) XTCEXFALCC11 1)
58 66
16 2 1NO-1NC 21 33 5 XTCEXFDC112) XTCEXFDCC112)
22 34
21 31
16 2 2NC 21 31 5 XTCEXFCC022) XTCEXFCCC022)
22 32
16 4 4NO 53 6373 83 5 XTCEXFAC40 XTCEXFACC40
54 6474 84
16 4 3NO-1NC 53 61 73 83 5 XTCEXFAC31 XTCEXFACC31
54 62 74 84
16 4 2NO-2NC 5 XTCEXFAC22 XTCEXFACC22
C on tacto rs and O ver load R elays
5361 71 83
54 62 72 84
16 4 1NO-3NC 536171 81 5 XTCEXFAC13 XTCEXFACC13
54 62 72 82
16 4 4NC 51 61 71 81 5 XTCEXFAC04 XTCEXFACC04
52 62 72 82
16 4 1NOE-1NCL 5765 71 83 5 XTCEXFAC221) XTCEXFACC221)
58 66 72 84
16 4 2NO-2NC 21 31 43 53 5 XTCEXFCC222) XTCEXFCCC222)
22 32 44 54
1) 1early-make contact, 1 late-break contact.
2) To avoid duplicate terminal numbers in contact sequence these auxilary contacts should be used with contactors with a built-in (normally open) contact.
16 2 2NO 53 63 5 XTCEXFATC20
54 64
16 2 1NO-1NC 53 61 5 XTCEXFATC11
54 62
16 2 2NC 51 61 5 XTCEXFATC02
52 62
16 4 2NO-2NC 5361 71 83 5 XTCEXFATC22 XTCEXFACC22
54 62 72 84
1) Front (Top) Mount Tall Version is for use with Frame B Electrical Wire Bridges and Link Kits and toolless
plug combination connection kits: XTCEXRLB, XTCEXDLB, XTPAXTPCB, XTPAXTPCRB, XTPAX.
Notes:
• Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (Positively driven) within the auxiliary contact modules.
(not N/O (early make) and N/C (late break) contacts) and for the built-in auxiliary contacts of the XTCE007B...-
XTCE032C...
• Auxilliary break contact can be used as a mirror contact to IEC/EN 60947-4-1 Annex F (not N/C (late break) contact)
• No auxiliary contacts can be fitted between 2 contactors.
14 24
16 2 1NO-1NC 53 61 5 XTCEXFAG11 —
54 62
16 2 1NO-1NC 13 21 5 XTCEXFBG11 —
14 22
16 2 2NC 11 21 5 XTCEXFBG02 —
12 22
16 4 4NO-0NC 13 23 33 43 5 XTCEXFBG40 XTCEXFBGC40
14 24 34 44
16 4 3NO-1NC 13 21 33 43 5 XTCEXFBG31 XTCEXFBGC31
14 22 34 44
16 4 2NO-2NC 13 21 31 43 5 XTCEXFBG22 XTCEXFBGC32
14 22 32 44
16 4 2NO-2NC 53 61 71 83 5 XTCEXFAG22 XTCEXFAGC22
54 62 72 84
16 4 1NO-3NC 13 21 31 41 5 XTCEXFBG13 XTCEXFBGC13
14 2232 42
16 4 0NO-4NC 5 XTCEXFBG04 XTCEXFBGC04
12 2232 42
16 4 1NO6-1NCL 13 21 35 47 5 XTCEXFBLG22 1) XTCEXFBLGC22 1)
14 22 36 48
1) 1early-make contact, 1 late-break contact.
10 2 1NO-1NC 53 61 1 XTCEXSCC11
54 62
1) Can be mounted to the left side of contactor only. Cannot be used in combination with Front (Top) Mount Auxiliary contacts or mechanical
interlocks
14 43 22 31
10 2 1NO-1NC1) 17
48
25
36 1 XTCEXSBLN11 —
18 47 26 35
10 2 1NO-1NC 53 84 61
72 1 XTCEXSCN11 XTCEXSCNC11
54 83 62 71
XTCEXCNC
XTCEXLBB
XTCEXPBB
XTCEXCLK3B
Star Delta Electrical Bridge for use with XTCE0 07B – XTCE015B 20 XTCEXSDBB
Star Delta Electrical Bridge for use with XTCE018C – XTCE032C 20 XTCEXSDBC
Star Delta Electrical Bridge for use with XTCE040D – XTCE065D 10 XTCEXSDBD
Star Delta Electrical Bridge for use with XTCE080F — XTCE150G 1 XTCEXSDBG
XTCEXSDBB Star Delta Electrical Bridge for use with XTCE185L – XTCE400M 1 XTCEXSDB400
Star Delta Electrical Bridge for use with XTCE50 0M 1 XTCEXSDB500
Star Delta Electrical Link Kit for use with XTCE007B – XTCE015B 1 XTCEXSDLB
Star Delta Electrical Link Kit for use with XTCE018C – XTCE032C 1 XTCEXSDLC
XTCEXSDLB
Reversing Electrical Link Kit for use with XTCE007B – XTCE012B 1 XTCEXRLB
Reversing Electrical Link Kit for use with XTCE018C – XTCE032C 1 XTCEXRLC
XTCEXRLC
XTCEXRBB
XTCEXTLA400
Set of 3 Lugs #4-500MCM 2-Phase Cu/Al 500A for use with XTCE500M 1 XTCEXTL500
Set of 3 Lugs #2-500MCM 2-Phase Cu/Al 650A for use with XTCE650N 1 XTCEXTL650
Set of 3 Lugs #2-500MCM 4-Phase Cu/Al 820A or use with XTCE820N 1 XTCEXTL820
XTCEXTL500
XTCEXTFB650
Control Wire Terminal Extension for use with XTCE080F – XTCE150G 10 XTCEXTCWG
XTCEXTCWG
C on tacto rs and O ver load R elays
Frame C
110 120 A XTCERENCOILCA
110 – 130 AD XTCERENCOILCAD
220 240 B XTCERENCOILCB
200 – 240 BD XTCERENCOILCBD
415 480 C XTCERENCOILCC
550 600 D XTCERENCOILCD
208 E XTCERENCOILCE
230 F XTCERENCOILCF
190 220 G XTCERENCOILCG
240 277 H XTCERENCOILCH
380 440 L XTCERENCOILCL
400 N XTCERENCOILCN
380 P XTCERENCOILCP
12 12 R XTCERENCOILCR
12 – 14 RD XTCERENCOILCRD
24 24 T XTCERENCOILCT
24 – 27 TD XTCERENCOILCTD
24 U XTCERENCOILCU
42 48 W XTCERENCOILCW
48 – 60 WD XTCERENCOILCWD
48 Y XTCERENCOILCY
Frame D
110 120 A XTCERENCOILDA
110 – 130 AD XTCERENCOILDAD
Frame G
100 – 120V 100 – 120V A XTCERENCOILGA
110 – 130V AD XTCERENCOILGAD
190 – 240 V 190 – 240V B XTCERENCOILGB
200 – 240V BD XTCERENCOILGBD
480 – 500V 480 – 500V C XTCERENCOILGC
380 – 440V 380 – 440V L XTCERENCOILGL
24 V 24V T XTCERENCOILGT
24 – 27V TD XTCERENCOILGTD
42 – 48V 42 – 48V W XTCERENCOILGW
48 – 60V WD XTCERENCOILGWD
Frame L 1)
110 – 250V 110 – 250V A XTCERENCOILLA
250 – 500V 250 – 500V C XTCERENCOILLC
24 – 48V TD XTCERENCOILLTD
48 – 110V 48 – 110V 48 – 110V Y XTCERENCOILLY
Frame M 1)
110 – 250V A XTCERENCOILMA
250 – 500V 250 – 500V C XTCERENCOILMC
24 – 48V TD XTCERENCOILMTD
48 – 110V 48 – 110V 48 – 110V Y XTCERENCOILMY
Frame N 1)
110 – 250V 110 – 250V 110 – 250V A XTCERENCOILNA
250 – 500V 250 – 500V C XTCERENCOILNC
48 – 110V 48 – 110V 48 – 110V Y XTCERENCOILNY
1) Electronic modules including coils.
C on tacto rs and O ver load R elays
1) For separate mounting, short circuit Type 1 rating is 500A and short circuit Type 2 rating is 400A.
Overload Circuit Symbol Contact For use Short-circuit protection (A) Eaton
Setting I r Configu- with Type 1 Type 2 Circuit list number
(A) ration Contactor Coordi- Coordi- Breaker
Amp Range nation, nation,
gG/gL gG/gL
XTOT160C3S
42 – 63 1NO-1NC 300 – 500A — — 150 XTOT063C3S
97 95
60 – 90 1NO-1NC 300 – 500A — — 250 XTOT090C3S
85 – 125 98 96 1NO-1NC 300 – 500A — — 500 XTOT125C3S
110 – 160 1NO-1NC 300 – 500A — — 600 XTOT160C3S
XTOBXDIND
Description Eaton
list number
XTOBXTSL
Description Eaton
list number
Terminal Shroud for use with XTOB…LC1 to XTCE185L, XTCE225L or XTCE250L XTOBXTSCL
This chapter provides product selection guidance for Eaton's XT range of Starters, which includes DOL,
DOL reversing and Star-delta configurations.
Standards
• IEC EN 60947
• CE Marked
• UL
• CSA
• CCC
• ATEX
80 90 25 37 48 63 45 — XTAE080F00_ _
95 110 30 45 57 75 55 — XTAE095F00_ _
1) First underscore (_) indicates coil suffix required.
2) Second underscore (_) indicates overload relay suffix required.
XTAE080F00
S tar ter s
Starter, DOL, Frame M
I e (A) Maximum kW Ratings AC-3, 3-Phase Motors 50 – 60 Hz Auxiliary Eaton
AC-3 AC-1 Contacts list number 1)2)
220/ 380/ 415V 660/ 1000V
230V 400V 690V
18 5 7.5 8 11 XTAR018C21_ _
25 7.5 11 14.5 14 XTAR025C21_ _
XTAR018C21 32 10 15 18 17 XTAR032C21_ _
1) First underscore (_) indicates coil suffix required.
2) Second underscore (_) indicates overload relay suffix required.
80 25 37 48 63 XTAR080F11_ _
95 30 45 57 75 XTAR095F11_ _
1) First underscore (_) indicates coil suffix required.
XTAR080F11 2) Second underscore (_) indicates overload relay suffix required.
1)
XTAR115G11 Underscore (_) indicates coil suffix required.
2) Underscore (_) indicates overload relay suffix required.
S tar ter s
380V P
12V 12V R
24V U
42V 48V 60 Hz W
48V Y
110 – 130V AD 1)
200 – 240V BD 1)
12 – 14V RD 1)
24 – 27V TD 1)
48 – 60V WD 1)
Frame G
100 – 120V 100 – 120V A
190 – 240V 190 – 240V B
24V 24V T
480 – 500V 480 – 500V C
380 – 440V 380 – 440V L
42 – 48V 42 – 48V W
24 – 27V TD 1)
110 – 130V AD 1)
200 – 240V BD 1)
48 – 60V WD 1)
Frame L – M
110 – 250V 110 – 250V 110 – 250V A
250 – 500V 250 – 500V C
48 – 110V 48 – 110V 48 – 110V Y 1)
24 – 48V TD 1)
1) With DC operation: Integrated diode-resistor combination, coil rating 2.6W.
Frame B
0.1 – 0.16 7 – 15A XTOBP16BC1 P16
0.16 – 0.24 7 – 15A XTOBP24BC1 P24
0.24 – 0.4 7 – 15A XTOBP40BC1 P40
0.4 – 0.6 7 – 15A XTOBP60BC1 P60
0.6 – 1 7 – 15A XTOB001BC1 001
1 – 1.6 7 – 15A XTOB1P6BC1 1P6
1.6 – 2.4 7 – 15A XTOB2P4BC1 2P4
2.4 – 4 7 – 15A XTOB004BC1 004
4–6 7 – 15A XTOB006BC1 006
6 – 10 7 – 15A XTOB009BC1 010
9 – 12 9 – 15A XTOB012BC1 012
12 – 16 12 – 15A XTOB016BC1 016
Frame C
0.1 – 0.16 18 – 32A XTOBP16CC1 P16
0.16 – 0.24 18 – 32A XTOBP24CC1 P24
0.24 – 0.4 18 – 32A XTOBP40CC1 P40
0.4 – 0.6 18 – 32A XTOBP60CC1 P60
0.6 – 1 18 – 32A XTOB001CC1 001
1 – 1.6 18 – 32A XTOB1P6CC1 1P6
1.6 – 2.4 18 – 32A XTOB2P4CC1 2P4
2.4 – 4 18 – 32A XTOB004CC1 004
4–6 18 – 32A XTOB006CC1 006
6 – 10 18 – 32A XTOB010CC1 010
10 – 16 18 – 32A XTOB016CC1 016
16 – 24 18 – 32A XTOB024CC1 024
24 – 32 25 – 32A XTOB032CC1 032
Frame D
6 – 10 40 – 65A XTOB010DC1 010
10 – 16 40 – 65A XTOB016DC1 016
16 – 24 40 – 65A XTOB024DC1 024
24 – 40 40 – 65A XTOB040DC1 040
40 – 57 50 – 65A XTOB057DC1 057
S tar ter s
Frame N
42 – 63 580 – 650A XTOT063C3S 063
60 – 90 580 – 650A XTOT090C3S 090
85 – 125 580 – 650A XTOT125C3S 125
110 – 160 580 – 650A XTOT160C3S 160
160 – 240 580 – 650A XTOT240C3S 240
190 – 290 580 – 650A XTOT290C3S 290
270 – 400 580 – 650A XTOT400C3S 400
360 – 540 580 – 650A XTOT540C3S 540
420 – 630 580 – 650A XTOT630C3S 630
1) Eaton list number refers to direct mount overload relay. Add an S to the end of the Eaton list number for separate mount.
S tar ter s
S tar ter s
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOB…FC1
Auxiliary Contacts 1 XTCEXFBG11
140 37 75 75 90 90 < 20 Star Delta Link 2 XTCEXSDLF
K1M Main Contactor 1 XTCE095F10_
K5M Delta Contactor 1 XTCE095F00_
K3M Star Contactor 1 XTCE065D00_
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOB…FC1
Auxiliary Contacts 2 XTCEXFBG11
165 45 90 110 110 132 < 20 Star Delta Link 1 XTCEXSDLF
1) Underscore (_) indicates coil suffix required. See page 48.
Starters, Star Delta, Frame G, Parts List
I e (A) Maximum kW Ratings AC-3 Maximum Component Quantity Eaton
AC-3 3-Phase Motors 50 – 60 Hz Changeover Descriptions Required list number 1)
220/ 380/ 415V 500V 660/ Time (sec)
230V 400V 690V
200 55 110 132 132 160 < 20 K1M Main Contactor 1 XTCE115G10_
K5M Delta Contactor 1 XTCE115G00_
K3M Star Contactor 1 XTCE080F00_
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOB…GC1
Auxiliary Contacts 2 XTCEXFBG11
Star Delta Link 1 XTCEXSDLG
260 75 132 148 160 160 < 20 K1M Main Contactor 1 XTCE150G10_
K5M Delta Contactor 1 XTCE150G00_
K3M Star Contactor 1 XTCE080F00_
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOB…GC1
Auxiliary Contacts 2 XTCEXFBG11
Star Delta Link 1 XTCEXSDLG
1) Underscore (_) indicates coil suffix required. See page 48.
315 90 160 180 200 250 132 <30 K1M Main Contactor 1 XTCE185L22_
K5M Delta Contactor 1 XTCE185L22_
K3M Star Contactor 2) 1 XTCE115G00_
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOB…LC1
K3M Auxiliary Contact 1 XTCEXFBG22
Star Delta Link 1 XTCEXSDLL250
385 110 200 240 250 315 160 <20 K1M Main Contactor 1 XTCE225L22_
K5M Delta Contactor 1 XTCE225L22_
K3M Star Contactor 2) 1 XTCE150G00_
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOB…LC1
K3M Auxiliary Contact 1 XTCEXFBG22
Star Delta Link 1 XTCEXSDLL250
430 132 250 300 315 400 200 <30 K1M Main Contactor 1 XTCE250L22_
K5M Delta Contactor 1 XTCE250L22_
K3M Star Contactor 2) 1 XTCE185L22_
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOB…LC1
Star Delta Link 1 XTCEXSDLL250
1) Underscore (_) indicates magnet coil suffix required. See page 48.
2) If mechanical interlock of the star contactor is required, star contactor must be the same frame size as main and delta contactors.
515 160 300 348 355 450 200 <30 K1M Main Contactor 1 XTCE300M22_
S tar ter s
1000 300 560 610 710 900 355 <30 K1M Main Contactor 1 XTCE580N22_
K5M Delta Contactor 1 XTCE580N22_
K3M Star Contactor 2) 1 XTCE400M00_
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOT…C3S3)
1120 350 630 680 750 950 355 <30 K1M Main Contactor 1 XTCE650N22_
K5M Delta Contactor 1 XTCE650N22_
K3M Star Contactor 2) 1 XTCE400M00_
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOT…C3S3)
1290 400 710 760 900 1200 1400 <30 K1M Main Contactor 1 XTCE750N22_
K5M Delta Contactor 1 XTCE750N22_
K3M Star Contactor 2) 1 XTCE580N00_
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOT…C3S3)
1400 450 800 850 950 1300 1400 <30 K1M Main Contactor 1 XTCE820N22_
K5M Delta Contactor 1 XTCE820N22_
K3M Star Contactor 2) 1 XTCE580N00_
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOT…C3S3)
1700 560 1000 1050 1200 1700 1700 <20 K1M Main Contactor 1 XTCEC10N22_
K5M Delta Contactor 1 XTCEC10N22_
K3M Star Contactor 2) 1 XTCE650N00_
K1T Timing Relay 1 XTTR6A60S51B
Overload Relay 1 XTOT…C3S3)
1) Underscore (_) indicates magnet coil suffix required. See page 48.
2) If mechanical interlock of the star contactor is required, star contactor must be the same frame size as main and delta contactors.
3) Select/ complete Eaton List number for overload relay for (...) from page 48.
S tar ter s
Frame A – B
110V 120V A
220V 240V B
24V 24V T
240V 277V H
380V 440V L
48V WD 2)
24V TD
Frame C – F
110V 120V A
220V 240V B
24V 24V T
240V 277V H
380V 440V L
24V TD 2)
24 – 27V TD 2)
48 – 60V WD 2)
Frame G
100 – 120V 100 – 120V A
190 – 240V 190 – 240V B
24V 24V T
380 – 440V 380 – 440V L
24 – 27V TD 2)
Frame L-N
110 – 250V 110 – 250V 110 – 250V A
250 – 500V 250 – 500V C
48 – 110V 48 – 110V 48 – 110V Y 2)
24 – 48V TD 2)
1) Add suffix in place of underscore (_) to Eaton List Number.
2) With DC Operation: Integrated diode-resistor combination, coil rating 2.6W.
S tar ter s
Overload Contact Circuit Symbol For use Short-circuit protection (A) Eaton
Releases, I r Configuration with Type 1 Type 2 Circuit list number
Contactor Coordi- Coordi- Breaker
XTOB016BC1 Amp Range nation, nation,
gG/gL gG/gL
Overload Contact Circuit Symbol For use Short-circuit protection (A) Eaton
Releases, I r Configuration with Type 1 Type 2 Circuit list number
Contactor Coordi- Coordi- Breaker
XTOB032CC1 Amp Range nation, nation,
gG/gL gG/gL
Overload Contact Circuit Symbol For use Short-circuit protection (A) Eaton
Releases, I r Configuration with Type 1 Type 2 Circuit list number
Contactor Coordi- Coordi- Breaker
XTOB065DC1 Amp Range nation, nation,
gG/gL gG/gL
S tar ter s
9795 XTOB 010 DC1
6 – 10 1NO-1NC 40 – 65A 50 25 25
XTOB 016 DC1
10 – 16 1NO-1NC 40 – 65A 63 35 25
XTOB 024 DC1
16 – 24 1NO-1NC 2 4 6 9896 40 – 65A 63 50 30
9795 XTOB 040 DC1
24 – 40 1NO-1NC 40 – 65A 125 63 125
XTOB 057 DC1
40 – 57 1NO-1NC 50 – 65A 160 80 150
XTOB 065 DC1
50 – 65 1NO-1NC 2 4 6 9896 65A 160 100 150
Overload Contact Circuit Symbol For use Short-circuit protection (A) Eaton
Releases, I r Configuration with Type 1 Type 2 Circuit list number
Contactor Coordi- Coordi- Breaker
XTOB150GC1 Amp Range nation, nation,
gG/gL gG/gL
25 – 35 1NO-1NC 9795 115 – 150A 125 100 125 XTOB 035 GC1
35 – 50 1NO-1NC 115 – 150A 160 125 150 XTOB 050 GC1
50 – 70 1NO-1NC 115 – 150A 250 160 150 XTOB 070 GC1
2 4 6 9896
70 – 100 1NO-1NC 9795 115 – 150A 315 200 400 XTOB 100 GC1
95 – 125 1NO-1NC 115 – 150A 315 250 500 XTOB 125 GC1
120 – 150 1NO-1NC 150A 315 250 600 XTOB 150 GC1
2 4 6 9896
Overload Contact Circuit Symbol For use Short-circuit protection (A) Eaton
Releases, I r Configuration with Type 1 Type 2 Circuit list number
Contactor Coordi- Coordi- Breaker
XTOB150GC1S Amp Range nation, nation,
gG/gL gG/gL
25 – 35 1NO-1NC 9795 115 – 150A 125 100 125 XTOB 035 GC1S
35 – 50 1NO-1NC 115 – 150A 160 125 150 XTOB 050 GC1S
50 – 70 1NO-1NC 115 – 150A 250 160 150 XTOB 070 GC1S
2 4 6 9896
70 – 100 1NO-1NC 9795 115 – 150A 315 200 400 XTOB 100 GC1S
95 – 125 1NO-1NC 115 – 150A 315 250 500 XTOB 125 GC1S
120 – 150 1NO-1NC 150A 315 250 600 XTOB 150 GC1S
2 4 6 9896
Overload Contact Circuit Symbol For use Short-circuit protection (A) Eaton
Releases, I r Configuration with Type 1 Type 2 Circuit list number
XTOB250LC1
Contactor Coordi- Coordi- Breaker
Amp Range nation, nation,
gG/gL gG/gL
160 – 220 1NO-1NC 185 – 250A 400 315 800 XTOB 220 LC1
200 – 250 1NO-1NC 225 – 250A 400 31 600 XTOB 250 LC1
2 4 6 98 96
Overload Contact Circuit Symbol For use Short-circuit protection (A) Eaton
Releases, I r Configuration with Type 1 Type 2 Circuit list number
Contactor Coordi- Coordi- Breaker
Amp Range nation, nation,
gG/gL gG/gL
XTOT160C3S
42 – 63 1NO-1NC 300 – 500A — — 150 XTOT 063 C3S
97 95
60 – 90 1NO-1NC 300 – 500A — — 250 XTOT 090 C3S
85 – 125 1NO-1NC 98 96 300 – 500A — — 500 XTOT 125 C3S
110 – 160 1NO-1NC 300 – 500A — — 600 XTOT 160 C3S
160 – 240 1NO-1NC 300 – 500A — — 600 XTOT 240 C3S
97 95
190 – 290 1NO-1NC 300 – 500A — — 600 XTOT 290 C3S
270 – 400 1NO1-NC 98 96 300 – 500A — — 1000 XTOT 400 C3S
360 – 540 1NO-1NC 500A — — 600 XTOT 540 C3S
The XTPB and XTPR MMP's can also be wired in series with a magnetic contactor to complete the
assembly of a remotely operated, manual motor controller.
Standards
• IEC EN 60947-4-1
• CE Marked
When ordering, specify Eaton list numbers according to the following stipulations:
XT Manual Motor Protectors are selected based on the overload current range required for a given
motor. This current range is determined from the motor Full Load Ampere rating and Motor Service
Factor usually found on the motor nameplate.
Manu al Mo to r Pr otector s
0.63 0.4 – 0.63 8.8 0.09 0.12 0.18 0.25 0.25 XTPBP63BC1
1 0.63 – 1 14 0.12 0.25 0.25 0.37 0.55 XTPB001BC1
1.6 1 – 1.6 22 0.25 0.55 0.55 0.75 1.1 XTPB1P6BC1
2.5 1.6 – 2.5 35 0.37 0.75 1.1 1.1 1.5 XTPB2P5BC1
4 2.5 – 4 56 0.75 1.5 1.5 2.2 3 XTPB004BC1
6.3 4 – 6.3 88 1.1 2.2 3 3 4 XTPB6P3BC1
10 6.3 – 10 140 2.2 4 4 4 7.5 XTPB010BC1
12 8 – 12 168 3 5.5 5.5 5.5 11 XTPB012BC1
16 10 – 16 224 4 7.5 9 9 12.5 XTPB016BC1
20 16 – 20 280 5.5 9 11 12.5 15 XTPB020BC1
25 20 – 25 350 5.5 12.5 12.5 15 22 XTPB025BC1
Manu al Mo to r Pr otector s
Frame B
0.16 0.1 – 0.16 2.2 — — — — 0.06 XTPRCP16BC1
0.25 0.16 – 0.25 3.5 — 0.06 0.06 0.06 0.12 XTPRCP25BC1
0.4 0.25 – 0.4 5.6 0.06 0.09 0.12 0.12 0.18 XTPRCP40BC1
0.63 0.4 – 0.63 8.8 0.09 0.12 0.18 0.25 0.25 XTPRCP63BC1
1 0.63 – 1 14 0.12 0.25 0.25 0.37 0.55 XTPRC001BC1
1.6 1 – 1.6 22 0.25 0.55 0.55 0.75 1.1 XTPRC1P6BC1
2.5 1.6 – 2.5 35 0.37 0.75 1.1 1.1 1.5 XTPRC2P5BC1
4 2.5 – 4 56 0.75 1.5 1.5 2.2 3 XTPRC004BC1
6.3 4 – 6.3 88 1.1 2.2 3 3 4 XTPRC6P3BC1
10 6.3 – 10 140 2.2 4 4 4 7.5 XTPRC010BC1
12 8 – 12 168 3 5.5 5.5 5.5 11 XTPRC012BC1
16 10 – 16 224 4 7.5 9 9 12.5 XTPRC016BC1
Manu al Mo to r Pr otector s
1.14 1.22
1NO-2NC 1.131.21 1.31 1 XTPAXSA12 — —
L1L2 L3
1.54 1.62
L1L2 L3
1.54
0NO-1NC 1.51
— — 5 XTPAXFAC01
L1L2 L3
1.52
L1L2 L3
“+”
XTPAXSATR20 “ >”
Trip “+” 4.44 4.14
L1L2 L3
“+”
“ >”
2NC On/Off “+” “ ” 2 XTPAXSATR02
4.31 4.21
L1L2 L3
“+”
“ >”
Trip “+” 4.32 4.22
L1L2 L3
“+”
“ >”
2NO 2 XTPAXFAEM20
Manu al Mo to r Pr otector s
3.13 3.23
3.14 3.24
Eaton Eaton
list number list number
XTPAXSR220V50H
Shunt Trip 110V50H C1 2 XTPAXSR110V50H —
Shunt Trip 110VDC 2 XTPAXSR110VDC —
Shunt Trip 120V60H 2 XTPAXSR120V60H —
Shunt Trip 125VDC 2 XTPAXSR125VDC —
C2
Eaton Eaton
list number list number
XTPAXUVR220V50H
Undervoltage release 110V50H D1 2 XTPAXUVR110V50H —
Undervoltage release 120V60H 2 XTPAXUVR120V60H —
Undervoltage release 208V60H 2 XTPAXUVR208V60H —
Undervoltage release 220V50H U 2 XTPAXUVR220V50H —
D2
T
XTPAXCL
Manu al Mo to r Pr otector s
240 mm. Carrier with extension shaft included.
• With ON/OFF switch position and "+" (tripped), lockable with 3 padlocks, 4 – 8 mm hasp.
Rotary Handle Mech IP65 Black — For use as main switch to IEC/EN 60204 1 XTPAXRHM165B
Rotary Handle Mech IP65 Red/Yellow — For use as main switch with 1 XTPAXRHM265RY
Emergency-Stop function to EN 60204
Rotary Handle Mech IP65 Black — For use as main switch to EN 60204 in MCC 1 XTPAXRHM365B
XTPAXRHM165B power distribution systems and with B-Frame XTPR when installed rotated 90°.
Telescoping Adapter, 75 – 115 mm Depth, for use with XTPB and B-Frame XTPR 1 XTPAXTEA
MMPs
XTPAXTEA
Sealing Wire for B-Frame XTPR. To prevent tampering with the overload release 5 XTPAXSW
and the test function
XTPAXSW
Manual Motor Protectors, Pushbutton and Rotary, Frame B, Three-Phase Commoning Link
• Protected against accidental contact. B-Frame short circuit proof Ue = 690V, Iu = 63A; D-Frame short
circuit proof Ue = 690V, Iu = 128A.
Manual Motor Protectors, Pushbutton and Rotary, Frame D, Three-Phase Commoning Link
• Protected against accidental contact. B-Frame short circuit proof Ue = 690V, Iu = 63A; D-Frame short
circuit proof Ue = 690V, Iu = 128A.
XTPAXCLKA2D
XTPAXIT
Manu al Mo to r Pr otector s
Front IP40 XTPB Only or with: XTPBXENCF40
Enclosure, with membrane actuation Front IP55 XTPAXFA…, XTPBXFAEM20, XTPBXENCF55
XTPAXSA…, XTPAXUVR…,
XTPBXENCF40 XTPAXSR…, XTPAXCL
Enclosure, lockable in OFF position Front IP55 XTPB Only or with: XTPBXENCFLO55
XTPAXFA…, XTPAXUVR…,
XTPAXSR…, XTPAXCL
Enclosure, lockable in OFF position in Front IP55 XTPB Only or with: XTPBXENCFLE55
combination with XTPBXFAEM20 Early XTPAXFA…, XTPBXFAEM20,
Make front mount auxiliary contact XTPAXUVR…, XTPAXSR…,
Enclosure, , with Emergency-Stop (E-Stop) Front IP55 XTPAXCL XTPBXENCFEK55
pushbutton actuator
Enclosure, , with Emergency-Stop (E-Stop) Front IP55 XTPBXENCFES55
pushbutton actuator, key release
Enclosure, cover with aperture IP41 with B-Frame XTPR Only or with: XTPAXENCS41 1)
dimensioned to accommodate front of vertical XTPAXFA…, XTPAXSA…,
MMP. IP40, when mounted turned through mounting XTPAXSATR…,
90° to left/right XTPAXUVR…, XTPAXSR…,
XTPAXENCS41
Enclosure, with black/grey rotary handle IP65 XTPAXCL XTPAXENCS65B 1)
Enclosure, with red/yellow rotary handle IP65 XTPAXENCS65RY 1)
for use as Emergency-Stop switches to
IEC/EN 60204
Enclosure, cover with aperture IP40 B-Frame XTPR Only or with: XTPAXENCS40 2)
dimensioned to accommodate front of XTPAXSA…, XTPAXUVR…,
MMP. XTPAXSR…, XTPAXCL
Enclosure, with black/gray rotary handle IP55 B-Frame XTPR Only or with: XTPAXENCS55B 2)
Enclosure, with red/yellow rotary handle IP55 XTPAXFA…, XTPAXSA…, XTPAXENCS55RY 2)
for use as Emergency-Stop switches to XTPAXUVR…, XTPAXSR…,
IEC/EN 60204 XTPAXCL
1) M25 metric cable entry knock-out, top and bottom. Cable push-through membrane, top and bottom, in the back plate and as a control line entry.
Includes N and PE terminals.
2) Integrated terminal for PE(N) connection, two M25 cable entry knockouts at the top and bottom.
Enclosure, with black/gray rotary handle IP65 B-Frame XTPR and XTPAXENCSEM65B
Enclosure, with red/yellow rotary handle IP65 XTPAXFAEM20 only or with: XTPAXENCSEM65RY
for use as Emergency-Stop switches to XTPAXFA…, XTPAXSA…,
IEC/EN 60204 XTPAXSATR…,
XTPAXENCSEM65B
XTPAXUVR…, XTPAXSR…,
XTPAXCL
Enclosure, with black/gray rotary handle IP55 B-Frame XTPR and XTPAXENCSEM55B
Enclosure, with red/yellow rotary handle IP55 XTPAXFAEM20 only or with: XTPAXENCSEM55RY
for use as Emergency-Stop switches to XTPAXFA…, XTPAXUVR…,
IEC/EN 60204 XTPAXSR…, XTPAXCL
Manu al Mo to r Pr otector s
Enclosure, with black/gray rotary handle IP65 D-Frame XTPR Only or with: XTPAXENCSD65B
Enclosure, with red/yellow rotary handle IP65 XTPAXFA…, XTPAXFAEM20, XTPAXENCSD65RY
for use as Emergency-Stop switches to XTPAXSA…, XTPAXSATR…,
IEC/EN 60204 XTPAXUVR…, XTPAXSR…,
XTPAXCL
Enclosure, cover with aperture Front IP40 B-Frame XTPR Only or with: XTPAXENCF40
dimensioned to accommodate front of XTPAXSA…, XTPAXUVR…,
MMP. XTPAXSR…, XTPAXCL
XTPAXENCF4O Enclosure, with black/gray rotary handle Front IP55 B-Frame XTPR Only or with: XTPAXENCF55B
Enclosure, with red/yellow rotary handle Front IP55 XTPAXSA…, XTPAXUVR…, XTPAXENCF55RY
for use as Emergency-Stop switches to XTPAXSR…, XTPAXFA…,
IEC/EN 60204 XTPAXCL
Manu al Mo to r Pr otector s
Neutral Terminal for connection of a fifth XTPBXENCF40, XTPBXENCF55, 20 XTPAXNT
conductor XTPAXENCF40,
XTPAXENCF55B,
XTPAXENCF55RY
XTPAXNT
This chapter provides product selection guidance for Eaton's XT range of Manual Motor Controllers
which combine a Manual Motor Protector (MMP's) with an XT contactor(s) to provide a complete
motor protection solution by combining motor disconnect function, thermal overload protection,
magnetic short circuit protection and remote control operation in one compact assembled unit.
Standards
• IEC EN 60947-4-1
• CE Marked
Description Eaton
list number
Includes: Mechanical & Electrical Connection Element for XTPR…B... (MMP) and XTCE…B… XTPAXTPCB 1)
(Contactor).
Includes: Mechanical & Electrical Connection Element for XTPR…B... (MMP) and XTCE…C… XTPAXTPCC 2)
(Contactor) and DIN Rail Adapter Plate.
XTPAXTPCB Includes: Mechanical & Electrical Connection Element for XTPR…D... (MMP) and XTCE…D… XTPAXTPCD
(Contactor) and DIN Rail Adapter Plate.
1) Comprised of mechanical connection element for MMP and contactor with main current wiring between MMP and contactor in the tool-less
plug connection.
2) Comprised of a top-hat rail adapter plate and main current wiring between MMP and contactor.
Description Eaton
list number
Includes: Mechanical & Electrical Connection Element for XTPR…B... (MMP) and (2) XTCR…B… XTPAXTPCRB 1)
(Contactors)
Includes: Mechanical & Electrical Connection Element for XTPR…B... (MMP) and (2) XTCR…C… XTPAXTPCRC 2)
(Contactors) and DIN Rail Adapter Plate.
XTPAXTPCRB Includes: Mechanical & Electrical Connection Element for XTPR…D... (MMP) and (2) XTCR…D… XTPAXTPCRD
(Contactors) and DIN Rail Adapter Plate.
1) Comprised of mechanical connection element for MMP and contactor with reversing combination main current wiring in the tool-less plug con-
nection. Control cables for electrical interlocking in toolless plug connection: K1M:A1 - K2M:21, K1M:21 - K2M:A1, K1M:A2 - K2M:A2.
2) Comprised of a top-hat rail adapter plate and reversing combination main current wiring.
Manual Motor Controller, DOL Reversing, Frame B MMP + (2) Frame C Contactors
FLA Maximum Motor Component Combinations Assembled
Adjustment Ratings Controller 1)
Range / Overload kW Manual Motor Connection Kit Contactor 1)
Release — Ir Protector Eaton
(Amps) list number
3-Phase
380 – 415V
Manual Motor Controller, DOL Reversing, Frame D MMP + (2) Frame C Contactors
• The connection between the XTPR…DC1 and the XTCE…C… contactor will be made with flexible wire
and mounted to the DIN Rail Adapter Plate (XTPAXTPCDP).
FLA Maximum Motor Component Combinations Assembled
Adjustment Ratings Controller 1)
Range / Overload kW Manual Motor Connection Kit Contactor 1)
Release — Ir Protector Eaton
(Amps) list number
3-Phase
380 – 415V
XTSR016DC
10 – 16 7.5 XTPR016DC1 XTCE018C01_ XTSR016DC_
16 – 25 12.5 XTPR025DC1 XTCE025C01_ XTSR025DC_
25 – 32 15 XTPR032DC1
1) Underscore (_) indicates Coil Suffix required. See page 68.
XTCE032C01_ XTSR032DC_
Manual Motor Co ntro ller s
Manual Motor Controller, DOL Reversing, Frame D MMP + (2) Frame D Contactors
• XTPAXTPCRD — Available June 2006 and will include two DIN Rail Adapter Plates (XTPAXTPCDP) and
electrical contact module (XTPAXECMRD). Prior to release of XTPAXTPCD, the connection between
the XTPR…DC1 and the two XTCE...D... contactors will be made with flexible wire and mounted to the
DIN Rail Adapter Plates (XTPAXTPCDP).
FLA Maximum Motor Component Combinations Assembled
Adjustment Ratings Controller 1)
Range / Overload kW Manual Motor Connection Kit Contactor 1)
Release — Ir Protector Eaton
(Amps) list number
3-Phase
XTSR04DD 380 – 415V
XTPAXTPCRD 2) XTSR040DD_
32 – 40 20 XTPR040DC1 XTCE040D01_
XTPAXTPCRD 2) XTSR050DD_
40 – 50 25 XTPR050DC1 XTCE050D01_
XTSR058DD_
50 – 58 30 XTPR058DC1 XTPAXTPCRD 2) XTCE065D01_
XTSR063DD_
55 – 63 34 XTPR063DC1 XTPAXTPCRD 2) XTCE065D01_
1) Underscore (_) indicates Suffix required. See page 68.
Frame B Contactors
110V 120V A
220V , 240V B
230V F
24V 24V T
415V 480V C
550V 600V D
208V E
190V 220V G
240V 277V H
380V 440V L
400V N
380V P
12V 12V R
24V U
42V 48V W
48V Y
120V AD 2)
220V BD 2)
12V RD 2)
24V TD
48V WD 2)
Frame C and D Contactors
110V 120V A
220V 240V B
230V F
24V 24V T
415V 480V C
550V 600V D
208V E
190V 220V G
240V 277V H
380V 440V L
400V N
380V P
12V 12V R
24V U
42V 48V W
48V Y
110-130V AD 2)
200-240V BD 2)
12-14V RD 2)
24-27V TD
Manual Motor Co ntro ller s
48-60V WD 2
1) Add suffix in place of underscore (_) to Eaton list number
2) With DC Operation: Integrated diode-resistor combination, coil rating 2.6W.
Miniature Controls 84
Miniature Contactors, Accessories and Overload Relays, dimensional drawings 84
Miniature Contactors, Wiring Diagrams 85
Miniature Contactors, Eaton Numbering System 86
Miniature Overload Relays, Eaton Numbering System 86
Miniature Contactors, Technical Data and Standards, General Specifications 87
Miniature Contactors, Tecnhical Data and Standards, Magnet System 88
Miniature Contactors, Data and Standards, Utilisation ratings 89
Miniature Contactors, Technical Data and Standards, Auxiliary Contacts 90
Miniature Overload Relays, Settings 91
Miniature Overload Relays, Tripping Characteristic Chart 91
500V Type 2 Coordination, Contactor and Overload Relay (Motor Starter) with Fused Disconnect 163
690V Type 2 Coordination, Contactor and Overload Relay (Motor Starter) with Fused Disconnect 164
400/415V Contactor and Overload Relay (Motor Starter) with Circuit Breaker 165
Europe
Conformité Européen
(CE)
This mark denotes that the device carrying it conforms to all relevant requirements and specifications. The mandatory
application of this mark therefore enables the unrestricted use of marked devices within the European economic area.
Since January 1996, all devices sold within the European union must comply with the Electromagnetic Compatibility (EMC)
Directive. XT has passed the required tests to these Directives, and the devices carry the CE mark, demonstrating compliance
with the EMC Directive. Because devices bearing the CE mark comply with the harmonized standards, approval and the
associated marking is no longer required in the following countries:
Belgium Netherlands
Comité Electro- Naamloze Vennootschap
technique Belge tot Keuring van
Belgisch Elektro- Electrotechnische
technisch Comité Materialien
(CEBEC) (KEMA)
Denmark Norway
Danmarks Elektriske Norges Elektriske
Materielkontrol Materiellkontrol
(DEMKO) (NEMKO)
Finland Sweden
(FIMKO) Svenska
Elektriska Materiel-
Kontrollanstalten
(SEMKO)
France
Union Technique
de l’Electricité Switzerland
(UTE) Schweizerischer
Elektrotechischer
Verein
(SEV)
Canada
Canadian Standards
Association
(CSA)
South Africa
ZA
SABS
Argentina
Selection of Devices
”Selection appropriate for export” does not mean merely meeting the requisite approvals and conformity to relevant
specifications. The meaning of the term goes a great deal further by even including that equipment and installations must be
designed to a concept with export in mind.
The following are important criteria for selecting switchgear suitable for export:
• For motor-protective circuit-breakers
Use inherently short-circuit proof switches capable of controlling the highest prospective fault levels at the point of installation
without the need for back-up protection.
- Advantage:
– No restrictions whatsoever for installation
– Complete independence from the on-site protective system
– No problems getting spare parts
• For circuit-breakers
Use types with visible contacts, quick-make and quick-break operation as standard. Use current-limiting circuit-breakers for high
short-circuit levels. Selective switches are recommended for the selective graduation of networks.
- Advantage:
– Independence from local accident prevention regulations requiring visible contacts, and safety faults caused by
inexperienced operating personnel.
– The effects of short-circuits are kept to a minimum.
– Fuseless installations offer greater safety and reliability in plant operation. In the event of a fault, only the faulty section of
the system is isolated.
• For contactors
Use contactors whose entire range provides consistently reliable operation in the event of voltage drops (consistently down to
80% Un should be aimed for) and whose contact system will not assume an indeterminate position either on closing or on
opening in such conditions.
- Advantage:
– During the electrification work in areas such as Africa and the Middle East, an insufficient voltage stability is — at least for a
certain time — likely in many applications (for example due to long spur lines or small local generators). The use of devices
that fulfill the above requirements will eliminate one of the main failure causes related to contactors.
• For enclosures
T echn ic al de ta ils
Use insulated enclosures with transparent covers (i.e. “totally insulated” enclosures).
- Advantage:
– Total insulation is the best possible protective measure from the user’s point of view, avoiding reliance on the possibly
doubtful skills of unknown installation personnel. Furthermore, protective measures based on earthing are often extremely
difficult, if not impossible (in the Middle East, for example, due to the dryness of the ground).
– Insulated enclosures completely eliminate the need for any additional protection against corrosion. The transparent covers
contribute
significantly to the correct operation of a system, because switchgear operation can be monitored even with the doors or
covers closed, thus virtually eliminating the possibility of these being left open through carelessness. The transparent cover
is an important contribution to safety, especially where exports to areas of uncertain skills are concerned.
Test Authorities
USA
USA
UL
Canada
CDN
CSA
Romania
RO
ICECON
Russia
RUS
GOST-R
South Africa
ZA
SABS
Slovakia
SK
SKTC
Poland
PL
BBJ-SEP
Turkey
TR
TSE
China
PRC
CCC
T echn ic al de ta ils
Ukraine
UA
Ukrain-GOST
Shipping Classifications
Germany
Germanischer Lloyd
(GL)
Great Britain
Lloyd‘s Register of
Shipping (LR)
Russia
Russian Maritime
Register of Shipping
(RS)
Italy
Registro Italiano Navale
(RINA)
Norway
Det Norske Veritas
(DNV)
Poland
Polski Rejestr Statkow
(PRS)
T echn ic al de ta ils
5.5 M4
58 50
52 – 54 35
45
43
M4
58 45 50
35
45 65.3
M4
62.5 50
35
45 52 – 54
T echn ic al de ta ils
M4
58 50
45 83 – 86 35
36
4 x M4 Dia.
18 68
45
60
45 75
116.3
T echn ic al de ta ils
XT RE C 10 B 22 AD
Product Line Prefix Coil Code
XT = XT IEC Power Control See Table 4 on Page 3.
XT MT 6 B 30S 11 B
Product Line Prefix Coil Code
XT = XT IEC Power Control B = 24 – 240V AC/DC
180°
A1-A2
A1-A2 15-18 A1-A2
OFF ON OFF
15-18
15-18 LED
t t t t t
LED On-Delayed LED
A1-A2
17-18
A1-A2 A1-A2 17-28
15-18 15-18 t tu
t 0.5 s Power LED
t t t t
LED
T echn ic al de ta ils
D M4
58 50
[1.97]
35
[1.38]
45 D1
[1.77]
XTMC XTMCC
D 52 [2.05] 54 [2.13]
D1 83 [3.27] 86 [3.39]
5.5
[.22]
106 49
[4.17] [1.93]
32 58
[1.26] [2.28]
45
[1.77]
≥ 5 [.20]
61
[2.40]
T echn ic al de ta ils
108
[4.25]
90 94
[3.54] [3.70]
Miniature Contactors DOL Reversing with overload
relay and auxiliary contact
58
[2.28]
63
[2.48]
58
[2.28]
90 94
[3.54] [3.70]
Miniature Contactors DOL Reversing with
Mechanical Interlock
61
[2.40]
108
[4.25]
180 83
[7.09] [3.27]
62.5
[2.46] 58 45
[2.28] [1.77]
45 52 45 69
[1.77] [2.05] [1.77] [2.72]
Miniature Contactors fitted with a Suppressor Miniature Contactors fitted with a Sealable Shroud
B
21
T echn ic al de ta ils
0 22
1 3 5 13 5 1 35
22 K1M K5M K3M
21 1 3 5 13 5
II 24 6 24 6 246
22 21 K1M K2M
14 13 A C 2 4 6 2 4 6
I
13 14 14
K1M 14
13 K2M
13
22
K1M 22
K2M 21 U1 V2 UV W
21
A1 K2M A1 V1 M1 W2 M
K1M W1 3 U2 M1 3
A2 A2 M1
XTRM Reversing Contactor Star Delta Power Wiring Diagram XTRM Reversing Contactor
Control Wiring Diagram Power Wiring Diagram
XT MC C 6 A 10 A
Designation Coil Codes
XT = XT IEC Power Control A= 110V 50 Hz, 120V 60 Hz N= 400V 50 Hz
B= 220V 50 Hz, 240V 60 Hz P= 380V 60 Hz
F= 230V 50 Hz R= 12V 50/60 Hz
Type T= 24V 50/60 Hz U= 24V 50 Hz
TD = 24V DC W= 42V 50 Hz, 48V 60 Hz
MC = 3-Pole FVNR Mini IEC Contactor C= 415V 50 Hz, 480V 60 Hz Y= 48V 50 Hz
MF = 4-Pole FVNR Mini IEC Contactor D= 550V 50 Hz, 600V 60 Hz AD = 120V DC
MR = 3-Pole FVR Mini IEC Contactor E= 208V 60 Hz BD = 220V DC
G= 190V 50 Hz, 220V 60 Hz RD = 12V DC
H= 240V 50 Hz, 277V 60 Hz WD = 48V DC
Terminations
L= 380V 50 Hz, 440V 60 Hz
Blank = Screw Terminals
C = Spring Cage Terminals
Integral Auxiliary Contact
01 = 1NC
Current Rating, AC-3
10 = 1NO
XTMC
6 = 6.6A Frame Size
9 = 9.0A
A = 45 mm Mini
XTMF
9 = 9.0A
XT OM P16 A C1
Designation Trip Class
XT = XT IEC Power Control C1 = Class 10A
Overload Release
P16 = 0.1 – 0.16A
P24 = 0.16 – 0.24A
P40 = 0.24 – 0.4A
P60 = 0.4 – 0.6A
001 = 0.6 – 1A
1P6 = 1 – 1.6A
2P4 = 1.6 – 2.4A
004 = 2.4 – 4A
006 = 4 – 6A
009 = 6 – 9A
012 = 9 – 12A
T echn ic al de ta ils
Environmental
Ambient Temperature -25° to 50°C
Mechanical Shock Resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms
Contactor without auxiliary contact module
Main contact — make contact 10g 10g 10g 10g 10g 10g
Main contact — break/make contact 10/8g 10/8g 10/8g 10/8g — —
Contactor with auxiliary contact module
Main contact — make contact 10g 10g 10g 10g 10g 10g
Main contact — make/break contact 20/20g 20/20g 20/20g 20/20g 20/20g 20/20g
Climatic Proofing Damp heat, constant, to IEC 60 068-2-78; Damp heat, cyclic, to IEC 60 068-2-30
Pollution Degree III/3 III/3 III/3 III/3 III/3 III/3
2h
100 XTOM
60
40
20
Minutes
10
6
4
2
1
40
3-Phase
20
Seconds
10
6
4
2-Phase
2
1
0.6
1 1.5 2 3 4 6 8 10 15 20
x Setting Current
These tripping characteristics are mean values of the spread at 20°C ambient temperature in a cold state. Tripping time
depends on response current. With devices at operating temperature, the tripping time of the overload relay reduces to
approx. 25% of the read off value. Specific characteristics for each individual setting range can be found on Page 18.
T echn ic al de ta ils
36
4 x M4 Dia.
18 68
45
60
45 75
116.3
68
26.4 4 x M4 Dia.
52.3
60
1.8 3.2
6.5
1.8
35
8.7 Typ. 75
5.1 125.2
45
71
2 x M4 Dia.
38
85
60.4
75
4 x M4 Dia.
104 105
57
86.4
45
34.4 4.7
55 6.9
113.8
132.1
146.8
4 x M4 Dia.
26.4 40 123.9 170
150
30 10
30 4.0
159 80
90 174.4
T echn ic al de ta ils
W1
W
11 Dia. M6 Dia.
H2 H1 H H3
D1 W2
W4 140
D 8
W W1 W2 W3 W4 H H1 H2 H3 D D1
Frame L 140 160 120 20 48 180 164 189 160 208 5
(185 – 250A)
Frame M 160 180 130 25 48 200 184 209 180 216 6
(300 – 500A)
A Dia.
M6
Dia.
165
T echn ic al de ta ils
80 W D1
250 140
270 232
W H D1 A (Dia.)
XTCE580N 35 286 6 11
XTCE650N 35 286 6 11
XTCE750N 45 296 6 13.5
XTCE820N 45 296 6 13.5
XTCEC10N 45 296 10 13.5
M6 Dia.
210 342
308
165
60 130 10
260
210 392
272 300
352
150 10
14 Dia 40 40 252
80 80
150 125
172.5 172.5
T echn ic al de ta ils
515
M6 Dia.
270
430
W D
Frame B (7 – 15A) Frame C (18 – 32A) Frame D (40 – 65A) Frame F – G (80 – 150A)
W H D W H D W H D W H D
90 68 125.2 90 85 147.3 110 115 146.8 180 170 174.4
15
515
20
430
T echn ic al de ta ils
270
300
XTCEXMLM
135 222 30
W H
XTCE500M 171 232
XTCE580N – XTCE650N 218 295
XTCE750N – XTCE820N 231 310
32
Approx.
28
9.2 9
25
T echn ic al de ta ils
35.5
29.5 48
39.5
65
45 83
20.3 51.5
79.2
95.5
60 102
Standard, Overload Relays, Frame B - C & D, DIN Rail or Panel Mount Adapter , dimensional drawing
D1
42.5
5 D2
H W D D1 D2
T echn ic al de ta ils
99
80 73
138
74
95 63
100 129
118 134
110
121
96 144
48 111
144
**
74 94
*
169
7
5* 7 Dia.
25 **
16.5
* = OFF
128 11 Dia. ** = RESET/ON
T echn ic al de ta ils
185
8 4.3 5 1.5
21
71 44 33 55 85
26 159
44
M4
26
55 *
* = RESET/ON
200
65 65
71
27
90 90 90
XTOT...C3S
T echn ic al de ta ils
Fitted Directly to the Contactor Mounted Seperatly from the Contactor Fitted Directly from the Contactor
60
117.8
83.3
88.4 To Reset
45 Mounting 139.8
Holes for
M4 or #8
35 Screws 97.8
(2 Places)
75
136.4
100.2
105.3 To Reset
60 Mounting 146
Holes for
45 Screws 132.5
105
T echn ic al de ta ils
174
93.6
98
To Reset
90 160
70 150
156 57 170
277
91
74
95
7 Dia. 100
118 134
150
110
T echn ic al de ta ils
328 523
34
144
XT CE C 007 B 01 AD P16
Designation Maximum Overload Rating
XT = XT Line of IEC Control XTAE, XTAS and XTAR Starters Only
Frame B Frame G
Type P16 = 0.1 – 0.16A 035 = 25 – 35A
P24 = 0.16 – 0.24A 050 = 35 – 50A
CE = 3-Pole FVNR IEC Contactor P40 = 0.24 – 0.4A 070 = 50 – 70A
CS = 3-Pole FVNR S Series IEC Contactor P60 = 0.4 – 0.6A 100 = 70 – 100A
CF = 4-Pole FVNR IEC Contactor 001 = 0.6 – 1A 125 = 95 – 125A
CR = 3-Pole FVR IEC Contactor 1P6 = 1.0 – 1.6A 150 = 120 – 150A
CC = IEC Capacitor Contactor 2P4 = 1.6 – 2.4A
AE = FVNR IEC Starter 004 = 2.4 – 4A Frame L
AS = FVNR S-Series IEC Starter 006 = 4 – 6A 070 = 50 – 70A
AR = FVR IEC Starter 010 = 6 – 10A 100 = 70 – 100A
012 = 9 – 12A 125 = 95 – 125A
016 = 12 – 16A 160 = 120 – 160A
Terminations 220 = 160 – 220A
Frame C
250 = 200 – 250A
Blank = Screw Terminals P16 = 0.1 – 0.16A
P24 = 0.16 – 0.24A Frame M
(6 – 65A); 5 mm (80 – 150A);
No Lugs (185 – 2000A) P40 = 0.24 – 0.4A 063 = 42 – 63A
P60 = 0.4 – 0.6A 090 = 60 – 90A
C = Spring Cage Terminals
001 = 0.6 – 1A 125 = 85 – 125A
(6 – 32A); Spring Cage Coil 160 = 110 – 160A
1P6 = 1.0 – 1.6A
Terminals Only (185 – 2000A) 2P4 = 1.6 – 2.4A 240 = 160 – 240A
004 = 2.4 – 4A 290 = 190 – 290A
Current Ratings, 006 = 4 – 6A 400 = 270 – 400A
010 = 6 – 10A 540 = 360 – 540A
AC-3 Frame Size 016 = 10 – 16A Frame N
Designation Auxiliary Contact 024 = 16 – 24A
032 = 24 – 32A 063 = 42 – 63A
007 = 7A B= 45 mm 01 = 1NC 090 = 60 – 90A
009 = 9A 10 = 1NO Frame D 125 = 85 – 125A
012 = 12A 010 = 6 – 10A 160 = 110 – 160A
015 = 15A 016 = 12 – 16A 240 = 160 – 240A
024 = 16 – 24A 290 = 190 – 290A
018 = 18A C= 45 mm 040 = 24 – 40A 400 = 270 – 400A
025 = 25A 057 = 40 – 57A 540 = 360 – 540A
032 = 32A 065 = 50 – 65A 630 = 420 – 630A
040 = 40A D = 55 mm 00 = 0NO-0NC Frame F
050 = 50A 035 = 25 – 35A
065 = 65A 050 = 35 – 50A
080 = 80A F= 90 mm 070 = 50 – 70A
095 = 95A 100 = 70 – 100A
115 = 115A G = 90 mm
150 = 150A Coil Codes
185 = 185A L= 140 mm 22 = 2NO-2NC
225 = 225A
250 = 250A M = 160 mm
300 = 300A
400 = 400A
500 = 500A
580 = 580A N = 250 mm
650 = 650A
750 = 750A
820 = 820A
C10 = 1000A
C14 = 1400A, AC-1 P = 260 mm
C16 = 1600A, AC-3 R = 515 mm
C20 = 2000A, AC-1 R = 515 mm T echn ic al de ta ils
180°
180°
Ambient Temperature: Enclosed 11 to 40°C 11 to 40°C 11 to 40°C 11 to 40°C
Open -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C
Ambient Storage Temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C
Environmental
Mechanical Shock Resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 mS
Main contact — NO Contact 10g 10g 10g 10g
Auxiliary contact — NO Contact 7g 7g 7g 7g
Auxiliary contact — NC Contact 5g 5g 5g 5g
Overvoltage Category/Pollution degree III/3 III/3 III/3 III/3
1) Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated.
180°
Ambient Temperature -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C
Ambient Storage Temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C
Environmental
Mechanical Shock Resistance (IEC/EN 60068-2-27)
Main contact — NO Contact 10 10 10 10 10 10
Auxiliary contact — NO Contact 7 7 7 7 7 7
Auxiliary contact — NC Contact 5 5 5 5 5 5
Overvoltage Category / Pollution Degree III/3 III/3 III/3 III/3
T echn ic al de ta ils
Type 1 Coordination
400V; gG/gL 500V 250 250 250 250
690V; gG/gL 690V 200 200 1) 1)
Nm 14 14 14 14
Control Circuit Cable Cross-Sections
Solid (mm2) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4)
1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4)
Flexible with ferrule (mm2) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5)
2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5)
Solid or Stranded (AWG) 18 – 14 18 – 14 18 – 14 18 – 14
Control Circuit Cable Connection Screw/Bolt
Tightening torque M3.5 M3.5 M3.5 M3.5
Nm 1.2 1.2 1.2 1.2
1) Contact Eaton.
180
180
Ambient Temperature: Enclosed -25 to 40°C -25 to 40°C -25 to 40°C -25 to 40°C
Open -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C
Ambient Storage Temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C
Environmental
Mechanical Shock Resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 mS
Main contact — NO Contact 10g 10g 10g 10g
Auxiliary contact — NO Contact 7g 7g 7g 7g
Auxiliary contact — NC Contact 5g 5g 5g 5g
Overvoltage Category/Pollution Degree III/3 III/3 III/3 III/3
T echn ic al de ta ils
Flexible with ferrule (mm2) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5)
2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5)
Solid or Stranded (AWG) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12)
Control Circuit Cable Connection Screw/Bolt M3.5 M3.5 M3.5 M3.5 M3.5 M3.5
Tightening torque
Nm 1.2 1.2 1.2 1.2 1.2 1.2
Tools
Main cable wrench 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm
Control circuit cable pozidrive screwdriver Size 2 Size 2 Size 2 Size 2 Size 2 Size 2
1) Screw tightening with flat cable terminal or cable terminal blocks. See terminal capacity for cable terminal blocks.
180°
Ambient Temperature -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C
Ambient Storage Temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C
Environmental
Mechanical Shock
Resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 mS
Main contact — NO Contact 10g 10g 10g 10g 10g 10g
Auxiliary contact — NO 10g 10g 10g 10g 10g 10g
Contact 8g 8g 8g 8g 8g 8g
Auxiliary contact — NC
Contact
Overvoltage Category/ III/3 III/3 III/3 III/3 III/3 III/3
Pollution Degree
Switching Capacity, kvar 1)
Individual Compensation
230V 87 — — 115 — —
400/420/440V 150 — — 200 — —
525V 190 — — 265 — —
690V 150 — — 200 — —
Group Compensation,
with Choke 80 100 110 130 160 160
230V 150 175 190 225 280 280
400/420/440V 200 230 260 290 370 370
525V 260 300 340 390 480 480
690V
Group Compensation,
without Choke 66 — — 85 — —
230V 115 — — 150 — —
400/420/440V 145 — — 195 — —
525V 115 — — 150 — —
690V
1) When using contactors for group compensation, a minimum inductance of approx. 6 uh per capacitor must be available to limit the high inrush current peaks. This corresponds to an
air-cored coil with 5 windings and a coil diameter of approximately 140 mm. The conductor cross-section must be selected according to the rated current per phase.
T echn ic al de ta ils
Busbar — Width in mm 50 50 50 50 50
Main Cable Connection Screw/Bolt M10 M10 M12 M12 M12
Tightening torque
Nm 24 24 35 35 35
Control Circuit Cable Cross-Sections
Solid (mm2) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5)
2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5)
Flexible with ferrule (mm2) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5)
T echn ic al de ta ils
2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5)
Solid or Stranded (AWG) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12)
Control Circuit Cable Connection Screw/Bolt M3.5 M3.5 M3.5 M3.5 M3.5
Tightening torque
Nm 1.2 1.2 1.2 1.2 1.2
1) Screw tightening with flat cable terminal or cable terminal blocks. See terminal capacity for cable terminal blocks.
180°
Ambient Temperature -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C
Ambient Storage Temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C
Environmental
Mechanical Shock Resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 mS (g)
Main contact — NO Contact 10 10 10 10 10
Auxiliary contact — NO Contact 10 10 10 10 10
Auxiliary contact — NC Contact 8 8 8 8 8
Overvoltage Category/Pollution Degree III/3 III/3 III/3 III/3 III/3
Switching Capacity, kvar 1)
Individual Compensation
230V 175 — — — —
400/420/440V 300 — — — —
525V 400 — — — —
690V 300 — — — —
1) When using contactors for group compensation, a minimum inductance of approx. 6 uh per capacitor must be available to limit the high inrush current peaks. This corresponds to an
air-cored coil with 5 windings and a coil diameter of approximately 140 mm. The conductor cross-section must be selected according to the rated current per phase.
T echn ic al de ta ils
XTCE185L 2 1 6
XTCE225L 2 1 6
XTCE250L 2 1 6
XTCE300M 3 2 7
XTCE400M 3 2 7
XTCE500M 3 2 7
XTCE580N 3 4 5
XTCE650N 3 4 5
XTCE750N 3 4 5
XTCE820N 3 4 5
Ops./h
4000
3000 햲
햳
햴
2000
1500 햵
1000
800
600
500
햶
400
햷
300
200
햸
150
100
50
0 10 20 30 40 50 60 70 80 90 100 %
PN [kW]
T echn ic al de ta ils
500V 11 13 16 29 36 40 47
660/690V 12 14 17 26 35 45 48
1000V — — — — — — —
AC-6A Operation
Transformer Loads Values are application specific. Calculation is IeAC-3 = X / 6 *leTransformer where the X is the inrush
current of the transformer and leTransformer is the nominal current. 2)
AC-6B Operation
Capacitor Loads
Individual compensation rated operational
current Ie of three-phase capacitors in
amperes
Up to 525V — — — — — — —
690V — — — — — — —
Maximum inrush current peak (x Ie) 30 30 30 30 30 30 30
Component Lifesaving (Operations) — — — — — — —
Maximum Operating Frequency (ops/hr) — — — — — — —
1) At maximum permissible ambient temperature.
2) Example — The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A =
30A. Using an XTCE032C (32A AC-3) contactor is recommended.
220V — — — — — — —
440V — — — — — — —
kW A kW A AC-4/400 V
AC-3/400 V
75
55
45
37
30 65 XTCE065D
22 50 XTCE050D 6
18.5 40 XTCE040D 25 XTCE065D
15 32 XTCE032C 4.5 21 XTCE050D
18 XTCE040D
11 25 XTCE025C 4 15 XTCE032C
13 XTCE025C
7.5 18 XTCE018C
10 XTCE018C
5.5 12 XTCE012B
2.2
4 9 XTCE009B 2.2 7 XTCE012B
6 XTCE009B
3 7 XTCE007B
5 XTCE007B
1.5
4
3
0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 1 2 4 6 10 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 1 2 4 6 10
Component Lifespan [Millions of Operations] Component Lifespan [Millions of Operations]
Normal Switching Duty - XTCE007B - XTCE065D Extreme Switching Duty - XTCE007B - XTCE065D
kW A kW A AC-4/400 V
560 1000 XTCEC10N AC-3/400 V
450 820 XTCE820N 355 656 XTCE820N
400 750 XTCE750N 315 576 XTCE750N
355 650 280 512 XTCE650N
XTCE650N 250 456 XTCE580N
315 580 XTCE580N 200 XTCE500M
360
Rated Output of Three-Phase Motors 50-60 Hz
400 XTCE400M
Rated Operational Current e 50-60 Hz
6.5
11 23 2.2
7.5 5
16
0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 1 2 4 6 10 1.5 3.5
0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 1 2 4 6 10
Component Lifespan [Millions of Operations]
Component Lifespan [Millions of Operations]
Normal Switching Duty - XTCE185l - XTCEC10N Extreme Switching Duty - XTCE185L - XTCE820N
100
55
35
20
10
7
5
4
3
2
1
0.1 0.2 0.3 0.5 0.7 1 2 3 5 7 10
Component Lifespan [Millions of Operations]
A
10000 XTCE820N XTCEC10N, XTCEC14P, XTCEC20R AC-1/400 V
XTCE750N
8000 XTCE650N
XTCE580N
6000
XTCE500M
5000
XTCE400M
4000
XTCE300M
3000 XTCE250M
2500
Short-Time Current
2000 XTCE185L/XTCE225L
1500
1000
700
500
400
300
200
T echn ic al de ta ils
XTCE007B XTCE009B XTCE012B XTCE015B XTCE018C XTCE025C XTCE032C XTCE040D XTCE050D XTCE065D
Frame
Voltage Tolerance
Pick-Up (x Uc)
AC operated 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1
DC operated 0.8 – 1.19 0.8 – 1.19 0.8 – 1.19 0.8 – 1.19 0.7 – 1.2 0.7 – 1.2 0.7 – 1.2 0.7 – 1.2 0.7 – 1.2 0.7 – 1.2
1) 1) 1) 2) 2) 2) 2) 2) 2) 2)
Drop-Out (x Uc)
AC operated 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6
DC operated 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6
Power Consumption of the coil at cold state and 1.0 x Uc
AC operated
Pick-Up VA 24 24 24 24 50 52 52 149 149 149
Pick-Up W 19 19 19 19 40 40 40 80 80 80
Single-voltage
coil 50 Hz
Sealing VA 3.4 3.4 3.4 3.4 7.1 7.1 7.1 16 16 16
Sealing W 1.2 1.2 1.2 1.2 2.1 2.1 2.1 4.3 4.3 4.3
60 Hz
Pick-Up VA 30 30 30 30 67 67 67 178 178 178
Pick-Up W 23 23 23 23 50 50 50 117 117 117
Sealing VA 4.4 4.4 4.4 4.4 8.7 8.7 8.7 19 19 19
Sealing W 1.4 1.4 1.4 1.4 2.6 2.6 2.6 5.3 5.3 5.3
50/60 Hz
Pick-Up VA 27 27 27 27 62 62 62 168 168 168
25 25 25 25 58 58 58 154 154 154
Pick-Up W 22 22 22 22 48 48 48 120 120 120
21 21 21 21 43 43 43 43 43 43
Sealing VA 4.2 4.2 4.2 4.2 9.1 9.1 9.1 22 22 22
3.3 3.3 3.3 3.3 6.5 6.5 6.5 14 14 14
Sealing W 1.4 1.4 1.4 1.4 2.3 2.3 2.3 5.3 5.3 5.3
1.2 1.2 1.2 1.2 2 2 2 4.3 4.3 4.3
DC operated
Pick-Up W 3 3 4.5 4.5 12 at 24V 12 at 24V 12 at 24V 12 at 24V 12 at 24V 12 at 24V
Sealing W 3 3 4.5 4.5 0.5 at 24V 0.5 at 24V 0.5 at 24V 0.5 at 24V 0.5 at 24V 0.5 at 24V
Duty Factor (%DF) 100 100 100 100 100 100 100 100 100 100
Switching Time at 100% Uc (approximate values)
Main Contact
AC operated
Closing delay (mS) <21 <21 <21 <21 <22 <22 <22 <18 <18 <18
Opening delay (mS) <18 <18 <18 <18 <14 <14 <14 <13 <13 <13
DC operated
Closing delay (mS) <31 <31 <31 <31 <47 <47 <47 <54 <54 <54
Opening delay (mS) <12 <12 <12 <12 <30 <30 <30 <24 <24 <24
Arcing time (mS) 10 10 10 10 10 10 10 10 10 10
Electromagnetic Compatibility (EMC)
Emitted interference To EN-60947-1
Noise Immunity To EN-60947-1
T echn ic al de ta ils
1) At 24V: 0.7 – 1.3 without additional auxiliary contact modules and ambient temperature +40°C [104°F].
2) Coil Suffix AD: Umin 110V DC/Umax 130V DC.
Coil Suffix BD: Umin 200V DC/Umax240V DC.
Example:
UC = 0.7 x Umin - 1.2 x Umax
UC = 0.7 x 24V - 1.2 x 27V DC
T echn ic al de ta ils
Rated impulse withstand voltage, (Uimp) 6000 6000 6000 6000 6000
VAC
Overvoltage category / pollution degree III/3 III/3 III/3 III/3 III/3
Rated insulation voltage, (Ui) VAC 690 690 690 690 690
Rated operational voltage, (Ue) VAC 500 500 500 500 500
Safe isolation to VDE 0106 Part 101 and
Part 101(A) in VAC
Between coil and auxiliary contacts 400 400 400 440 440
Between the auxiliary contacts 400 400 400 440 440
Rated Operational Current, le
AC-15
230V 6A 6A 6A 6A 6A
380/415V 4A 3A 4A 4A 4A
500V 1.5A — 1.5A 1.5A 1.5A
DC-3 L/R <5 mS 1)
24V 10A 10A 10A 10A 10A
60V 6A 6A 6A 6A 6A
110V 3A 3A 3A 3A 3A
220V 1A 1A 1A 1A 1A
Conventional thermal current, Ith 16A 16A 16A3) 10A 10A
Control circuit reliability <10-8, < one failure at 100 million operations
(at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA)
Component Lifespan, Operations x 106
at Ue = 230V, AC-15, 3A 1.3 1.3 1.3 1.3 1.3
2)
Short-circuit rating without welding
Maximum fuse, gG/gL 10A 10A 10A 16A 16A
1) Making and breaking conditions to DC-13, time L/R contact as stated.
2) See fuses overlay for time/current characteristic (on request).
3) Conventional thermal current(Ith) of XTCEXSCL - 10A
2 x (0.5 0 16)
Stranded mm2 1 x (0.5 - 25) 1 x (16 - 50) 1 x (16 - 120) 1 x (35 - 300)
2 x (0.5 0 16) 2 x (35 - 120)
Flat conductor number of segments mm2 6 x 9 x 0.8 — — 2 x (11 x 21 x 1)
x width x thickness
Tightening torgue Nm 4 4 14 —
Tool
Pozidriv screwdriver Size 2 2 — —
Hexagon socket-head spanner SW mm — — 5 6
Conventional thermal current
3 pole Ith A 50 100 180 400
4 pole Ith A 60 — — —
Eaton Built-in Aux Front (Top) Mount Side Mount Total Auxillary Contacts Available
list number 2-Pole 4-Pole 2-Pole
T echn ic al de ta ils
XTMC6A... - XTMC9A...
XTCE007B... - XTCE032C...
XTMCXF... A...
XTCEXF... C...
2 - Pole 0r 4 - Pole
XTCE007B... - XTCE032C...
XTCEXSCC11
XTCEXF...C...
XTCE018C... - XTCE032C...
2 - Pole 0r 4 - Pole
-OR-
+
XTCEXSBN11
XTCEXF...G... XTCEXF...G...
XTCEXSBN11
+ 2 - Pole + -OR- + 4 - Pole +
XTCE080F... - XTCE150G...
XTCEXSBN11
XTCEXSBN11
XTCEXSBN11
XTCEXSCN11
XTCEXF...G... XTCEXSCN11
XTCEXSBN11
XTCE080F... - XTCE150G...
+ 2 - Pole or 4 - Pole + -OR- + + + +
XTCEXSBN11 (Built-in)
XTCEXSBN11
XTCEXSCN11
XTCEXSCN11
XTCE185L... - XTCEC20R...
+ + + +
A2 2 4 6 14
B–C 1NC A1 1 3 5 21
A2 2 4 6 22
D–G — A1 1 3 5
A2 2 4 6
L–R 2NO-2NC A1 1 3 5 13 21 31 43
A2 2 4 6 14 22 32 44
Note:
The 7 – 32A XTCE Contactors have positively driven contacts between the integrated auxiliary contact and the auxiliary contact
module as well as within the auxiliary contact modules.
The 40 – 65A XTCE Contactors have positively driven contacts within the auxiliary contact module. 6 auxiliary contacts are
possible with a combination of side mounted and front mount auxiliary contacts.
21 21
0 0
22 22
22 21 22
II 21 II 1 3 5 13 5
22 21 22 21 K1M
14 13 14 13 2 4 6 K2M 2 4 6
I I
13 14 13 14
54 54 14 14
K1M K2M 53 K1M K2M
53 13 13
22 22
K2M 21 K1M 21
22 K2M K1M 22 U V W
21 21
A1 A1 A1 A1 M
K1M K2M K1M K2M M1
3
A2 A2 (-)N A2 A2
L1 L2 L3 L1 L2 L3
B 1 x In B1 x In
13 5 1 3 5 135 13 5 13 5 13 5
K1M 24 6 K5M 2 4 6 K3M 24 6
K1M 2 4 6 K5M 2 4 6 K3M 2 4 6
U1 V2 U1 V2
T echn ic al de ta ils
V1 M1 W2 V1 M1 W2
W1 3 U2 W1 3 U2
M1 M1
Setting Starting
A: IN x 0.58 < 15 sec
Motor Protection in the Star and Delta Configurations
B: IN x 1 15 – 40 sec
Only partial motor protection in star position
C: IN x 0.58 > 40 sec
Motor not protected in star position
Timing Relay set to approximately 10 sec
Overload Relays
These tripping characteristics are the mean values of the spread at 20°C ambient temperature in a cold state.
Tripping time depends on response current. With devices at operating temperature, the tripping time of the overload relay
reduces to approximately 25% of the read off value. Specific characteristics for each individual setting range can be found in
MN03402001E.
2h
100 XTOB...BC1,
60 XTOB...CC1,
40 XTOB...DC1
20
Minutes
10
6
4
2
1
40
3-Phase
20
Seconds
10
6
4
2-Phase
2
1
0.6
1 1.5 2 3 4 6 8 10 15 20
x Setting Current
Tripping Characteristics
T echn ic al de ta ils
T echn ic al de ta ils
T echn ic al de ta ils
The assembled Manual Motor Controller (MMC) consists of a XTPR Manual Motor Protector (MMP) and a XTCE contactor. Up
to 12A, the assembly can be mounted directly on DIN rail without an adapter. The contactors are supported mechanically with
a mechanical connection element (included in XTPAXTPCB). For 16A and above, the assembly is mounted via a DIN Rail
Adapter Plate (XTPAXTPCCP) and the electrical connection is made with electrical contact modules (XTPAXEMMC), both
included in XTPAXTPCC.
Service Factor Settings: For motors with a service factor (SF) of 1.15, use motor nameplate Full Load Amperes (FLA) to select
the appropriate motor controller —> I r = 1 x I n mot. For motors with a service factor (SF) of 1.0 or less, multiply the motor FLA
by 0.9 to select the appropriate motor controller —> I r = 0.9 x I n mot.
Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.
M
3~
93 45
T echn ic al de ta ils
45 5.5 44
74
85
Manual Motor Protectors — XTPB
93 45
45 50
88
94
Manual Motor Protectors, Manual Transformer Protectors —
XTPR…B, XTPT and XTPM
Manual Motor Protectors, Frame B, Rotary with Current Limiter, dimensional drawing
45
28
90 73 93
7.5 44 7.5
49.5 70
* IEC/EN 60715 DIN Rail
Manual Motor Protectors, Frame B, Rotary with Early-Make Auxilliary Contacts, dimensional drawing
80
XTPAXFAEM20
93 45 55
T echn ic al de ta ils
45 50 XTPAXFAEM20
68
86
MMPs with Early-Make Auxiliary Contacts — XTPR…BC1 +
XTPAXFAEM20
65
130 45 125
140
30 7.5
55 118
127
145
171
Manual Motor Protectors, Frame B and D, Standard Auxilliary Contacts, dimensional drawing
36 45 90
9 26
68
Standard Auxiliary Contact — XTPAXSA…
Manual Motor Protectors, Frame B and D, Trip Indicating Auxilliary Contact, dimensional drawing
36 45 90
9 26
68
T echn ic al de ta ils
Manual Motor Protectors, Frame B and D, Undervoltage / Shunt Release, dimensional drawing
36 45 90
18 49
68
Undervoltage / Shunt Release — XTPAXUVR…, XTPAXSR…
27 27
45 63
27
54
Overlapping Mounting
to Extend the Three-Phase
Commoning Link
36 36
205 14 33 170 14 33
36 36
151 14 33 117 14 33
36
36
T echn ic al de ta ils
98 14 33 260 14 33
36 36
232 14 33 115 14 33
56
7.5 31
XTPAXLSA
73
48
41
XTPAXIT
158 70
80 90
100
98
30 Drilling Dimensions
30
158 44
97.5 28 4.5
33
80 97.5
125.5 55 158 153
80 4.5 8
158
80 116.5
Insulated Enclosures for Surface Mounting, XTPBXENAS… and XTPBXENCS…
158
T echn ic al de ta ils
80 116.5
177.2
Insulated Enclosures for Surface Mounting, XTPBXENASEK65 and XTPBXENASES65
158
80 116.5
129.5
Insulated Enclosures for Surface Mounting, XTPBXENASLEGS and XTPBXENASLOGS
181 160
240
100 47.5
104
160 134
181
Insulated Enclosures for Surface Mounting - 197
XTPAXENAS4 and XTPAXENCS41 Insulated Enclosures for Surface Mounting — XTPAXENCSD65...
181 160
100 47.5
103
130
98
3
32
72
5.6 Dia.
72
240 193
30
T echn ic al de ta ils
69
129
90.2 93
115.2
69
129
90.2 93
115.2
175.9
69
129
90.2 93
115.2
69
129 55
85 80
96
124
98
30
30
28
58
21
129
55
85
80
96
124
T echn ic al de ta ils
98
Drilling Dimensions
30
30
44 114 28 M4
33
97 M4
43 Dia.
4R
64 48
116 – 118
64 48
62
19.5 70 – 72
Mounting Depth:
– 240
At least 100 Mounting Cutout - XTPAXENCF...
up to Cover Hinge
front edge of the panel
door/cover
XT PR 012 B C1
Designation Trip Class
XT = XT IEC Power Control C1 = Class 10
Blank = Magnetic only (No thermal trip)
Type
Frame Size
PB = Manual Motor Protector — Pushbutton
PR = Manual Motor Protector — Rotary B= 45 mm D = 55 mm
PM = Manual Motor Protector — Magnetic Only
PT = Manual Transformer Protector (High Mag.)
Current Ratings
B Frame
P16 = 0.16A 6P3 = 6.3A
P25 = 0.25A 010 = 10A
P40 = 0.40A 012 = 12A
P63 = 0.63A 016 = 16A
001 = 1A 020 = 20A
1P6 = 1.6A 025 = 25A
2P5 = 2.5A 032 = 32A
004 = 4A
D Frame
016 = 16A 050 = 50A
025 = 25A 058 = 58A
032 = 32A 063 = 63A
040 = 40A
T echn ic al de ta ils
1) When using the XTPM as short-circuit protection for motors with heavy starting duty, the rated operational current I must be derated during engineering with the following factors:
e
Electrical, operations (x 10 6) > 0.05 > 0.1 >1 > 0.1 > 0.005
T echn ic al de ta ils
Contact reliability (@ Ue = 24V DC, Umin – 17V, < 10-8 < 1 fault at 1 x 108 operations
Imin = 5.4 mA, fault probability (λ)
Positively driven contacts to ZH 1/457 Yes – Yes – –
Short-circuit rating without welding
Fuseless FAZ-B4/1-HI – FAZ-B4/1-HI – FAZ-B4/1-HI
Fuse (A gG/gL) 10 10 10 10 10
Terminal Capacity
Solid or flexible conductor with ferrule (mm2) 0.75 –2.5 0.75 – 1.5 0.75 – 2.5 0.75 – 1.5 0.75 – 2.5
Solid or stranded (AWG) 18 – 14 18 – 16 18 – 14 18 – 16 18 – 14
Description XTPAXUVR…
Cross-sections
Solid or flexible conductor with ferrule (mm2) 1 x (0.75 – 2.5)
2 x (0.75 – 2.5)
Solid or stranded (AWG) 1 x (18 – 14)
2 x (18 – 14)
Main Contacts
Rated operational voltage, Ue (V AC) 42 – 480
Rated operational voltage, Ue (V DC) 24 – 250
Pick-up voltage, x Us 0.85 – 1.1
Drop-out voltage, x Us 0.7 – 0.35
Power Consumption
Pick-up AC (VA) 5
Sealing AC (VA) 3
Description XTPAXCL
Rated Impulse withstand Voltage (Uimp), V AC 6000
Overvoltage Category/ Pollution Degree III/3
Rated operational voltage, Ue (V AC) 690
Rated interrupted current = Rated operational current 63
(lu = le) in amperes
Description XTPAXSR __
Cross-sections
Solid or flexible conductor with ferrule (mm2) 1 x (0.75 – 2.5)
2 x (0.75 – 2.5)
Solid or stranded (AWG) 1 x (18 – 14)
2 x (18 – 14)
Main Contacts
Rated operational voltage, Ue (V AC) 42 – 480
Rated operational voltage, Ue (V DC) 24 – 250
AC Operating Range, x Us 0.7 – 1.1
DC Operating Range, x Us (intermittent operation 5s) 0.7 – 1.1
Power Consumption
Pick-up AC (VA) 5
Sealing AC (VA) 3
Pick-up DC (VA) 3
Sealing DC (VA) 3
T echn ic al de ta ils
The time/current characteristic, the current limiting characteristics and the I2t characteristics were determined in accordance
with DIN VDE 0660 and IEC 60 947.
The tripping characteristic of the inverse-time delayed overload releases (thermal overload releases or “a” releases) for DC
and AC with a frequency of 0 to 400 Hz also apply to the time/current characteristic.
The characteristics apply to the cold state. At operating
temperature, the tripping times of the thermal releases are reduced to approximately 25%.
Under normal operating conditions, all three poles of the device must be loaded. The three main conducting paths must be
connected in series in order to protect single-phase or DC loads.
With 3-pole loading, the maximum deviation in the tripping time for 3 times the setting current and upwards is ±20% and thus
in accordance with DIN VDE 0165.
The tripping characteristics for the instantaneous, electromagnetic overcurrent releases (short-circuit releases or “n”
releases) are based on the rated current In, which is also the maximum value of the setting range for circuit-breakers with
adjustable overload releases. If the current is set to a lower value, the tripping current of the “n” release is increased by a
corresponding factor.
The characteristics of the electromagnetic overcurrent releases apply to frequencies of 50/60 Hz. Appropriate
correction factors must be used for lower frequencies up to 16-2/3 Hz, for higher frequencies up to 400 Hz and for DC.
Time/current characteristics, current limiting characteristics and I2t characteristics are available on request.
2h 2h
20 XTPB, XTPR Frame B 20 XTPR Frame D
10 10
Minutes
Minutes
5 5
2 2
1 1
40 40
20 20
Seconds
Seconds
10 10
5 5
2 XTPT 2
1 1
200 200
Milli-seconds
Milli-seconds
50 50
20 20
5 5
2 2
1.5 2 3 4 6 8 10 15 20 30 1.5 2 3 4 6 8 10 15 20 30
x Rated Operational Current x Rated Operational Current
MMP Tripping Characteristics — XTPB, XTPR Frame B and MMP Tripping Characteristics — XTPR Frame D
XTPT (not for XTPM)
T echn ic al de ta ils
cc
3
•
2
4.0 A
2
cc
2•
1
0.8 2.5 A
63/58 A
0.6 50/40/32 A
1.6 A 25 A
0.4 10
0.3 16 A
0.2 1A
0.1
0.08 0.63 A
0.06
0.04
0.03 0.4 A
0.02 Ue = 400 V
Ue = 400 V
0.015 0.25 A 1
0.01 1 10 100
1 1.5 2 3 4 6 8 10 15 20 3040 60 80100
cc rms [kA]
cc rms [kA]
MMP Let-Through Tripping Characteristics — XTPB, XTPR MMP Let-Through Tripping Characteristics — XTPR Frame
Frame B, XTPT D
XTPR Frame B, XTPT
106
8 XTPR Frame B
e
2 25 A
av
i dt XTPM
6 20 A
-w
2
[A s] 16 A
4
alf
th
3 10 A
1s
2
6.3 A
1.5
104
8
6
4.0 A
4
3
2
1.5 2.5 A
103
8
6
1.6 A
4
3
2
Ue = 400 V
1.5
102 1.0 A
1 1.5 2 3 4 6 8 10 15 20 3040 6080100
T echn ic al de ta ils
cc rms [kA]
Eaton list Rated FLA Short Maximum Protective Device for UL/CSA Group Protection
Number Uninterrupted Adjustment Circuit Max. RMS Sym Current — Maximum Fuse Circuit Breaker
Current — Range / Release — 600V (kA) Rating (A) Max (A)
Iu (Amps) Overload Irm (Amps) w/Current w/Current w/Current
Release — Limiter — Limiter — Limiter —
Ir (Amps) XTPAXCL XTPAXCL XTPAXCL
XTPB — Frame B, Manual Motor Protector with Thermal and Magnetic Trip
XTPBP16BC1 0.16 0.1 – 0.16 2.2 50 — 600 — 600 —
XTPBP25BC1 0.25 0.16 – 0.25 3.5 50 — 600 — 600 —
XTPBP40BC1 0.4 0.25 – 0.4 5.6 50 — 600 — 600 —
XTPBP63BC1 0.63 0.4 – 0.63 8.8 50 — 600 — 600 —
XTPB001BC1 1 0.63 – 1 14 50 — 600 — 600 —
XTPB1P6BC1 1.6 1 – 1.6 22 50 — 600 — 600 —
XTPB2P5BC1 2.5 1.6 – 2.5 35 50 — 600 — 600 —
XTPB004BC1 4 2.5 – 4 56 50 — 600 — 600 —
XTPB6P3BC1 6.3 4 – 6.3 88 50 — 600 — 600 —
XTPB010BC1 10 6.3 – 10 140 10 50 150 600 125 2) 600
XTPB012BC1 12 8 – 12 168 10 50 150 600 125 2) 600
XTPB016BC1 16 10 – 16 224 10 1) 50 1) 150 1) 600 1) 125 1)2) 600 1)
3) 1) 1) 1) 1) 1)
XTPB020BC1 20 16 – 20 280 10 18 150 600 125 600 1)
XTPB025BC1 3) 25 20 – 25 350
10 18 1) 150 1) 1)
125 600 1) 1) 600 1)
XTPR — Frame B (all Screw and Spring Cage terminal options), Manual Motor Protector with Thermal and Magnetic Trip
XTPRP16BC1 0.16 0.1 – 0.16 2.2 50 — 600 — 600 —
XTPRP25BC1 0.25 0.16 – 0.25 3.5 50 — 600 — 600 —
XTPRP40BC1 0.4 0.25 – 0.4 5.6 50 — 600 — 600 —
XTPRP63BC1 0.63 0.4 – 0.63 8.8 50 — 600 — 600 —
XTPR001BC1 1 0.63 – 1 14 50 — 600 — 600 —
XTPR1P6BC1 1.6 1 – 1.6 22 50 — 600 — 600 —
XTPR2P5BC1 2.5 1.6 – 2.5 35 50 — 600 — 600 —
XTPR004BC1 4 2.5 – 4 56 50 — 600 — 600 —
XTPR6P3BC1 6.3 4 – 6.3 88 50 — 600 — 600 —
XTPR010BC1 10 6.3 – 10 140 10 50 150 600 125 2) 600
XTPR012BC1 12 8 – 12 168 10 50 150 600 125 600
XTPR016BC1 16 10 – 16 224 10 50 150 600 125 2) 600
XTPR020BC1 20 16 – 20 280 10 18 150 600 125 600
XTPR025BC1 25 20 – 25 350 10 18 150 600 125 600
XTPR032BC1 32 25 – 32 448 10 18 150 600 125 600
XTPR — Frame D, Manual Motor Protector with Thermal and Magnetic Trip
XTPR016DC1 16 10 – 16 224 10 — 600 — 600 —
XTPR025DC1 25 16 – 25 350 10 — 600 — 600 —
XTPR032DC1 32 25 – 32 448 10 — 600 — 600 —
XTPR040DC1 40 32 – 40 560 10 — 600 — 600 —
XTPR050DC1 50 40 – 50 700 10 1) — 600 1) — 600 1) —
XTPR058DC1 58 50 – 58 812 10 1) — 600 1) — 600 1) —
— — —
XTPR063DC1 65 55 – 63 882 10 1) 600 1) 600 1)
XTPT — Frame D, Manual Motor Protector with Thermal and Magnetic Trip
T echn ic al de ta ils
Eaton list number Rated FLA Short Rated Short Circuit Breaking Capacity (kA)
Non-reversing Reversing Current — Adjustment Circuit Release 240V 480/277V 600/347V
Ie (Amps) Range / —
Overload Irm (Amps)
Release —
Ir (Amps)
Manual Motor Pprotectors with XTPAXSATR20 Signalling switch. Manual Motor Protectors with pushbutton
Separate “Short-Circuit” and “Tripped” signals. or EMERGENCY-STOP button in the system.
L1 L1
L2 L2
L3 L3
N N
F1 Max. 10A
F1 Max. 10A
F2 Max. 10A
H1
H2
1 3 5 4.43 4.13 1 3 5 D1 07
2 4 6 4.44 4.14 2 4 6 D2 08
Q1 S1 Q1 F4
S1
S2
S3
H1: “Short-Circuit” Signal The undervoltage release with leading auxiliary contac
H2: “Tripped” Signal prevents formation of parasitic voltages in the control
(MMP can be tripped by overload, when the MMP position is “OFF”. In the tripped positio
short-circuit, or auxiliary releases) the MMP, opening of these contacts is not assured.
1 3 5 1 3 5
Manual Motor Protectors, XTPB, XTPR 1P and 2P Circuits with DC and AC Current
T echn ic al de ta ils
...
XTPR6P3BC1
XTPR010BC1
XTPR016BC1
XTPR020BC1
XTPR025BC1
XTPR016DC1
XTPR025DC1
XTPR032DC1
XTPR040DC1
XTPR050DC1
XTPR058DC1
XTPR063DC1
The table indicates which minimum cable cross-sections are protected by XTPR motor protective circuit breakers up to their
rated conditional short circuit current I q .
Manual Motor Protectors, Fuseless Installation with XTPR, Back-Up Protection Diagrams
XTPR…B 100
XTPR…B + XTPAXCL
XTPR...B
415V AC Inherently
Back-up short-circuit-proof
cc rms [kA]
protection
Inherently short-circuit proof
50
range
with XTPAXCL
30
20
16
Rated
short-circuit
XTPR…B
breaking 10
cn
cc
capacity
range 6
XTPR…B
0.16... 1016 20 25
Rated
Current
n [A]
XTPR…D 100
XTPR...D + XTPAXCL
415V AC
Back-up
cc rms [kA]
protection
Inherently short-circuit proof
50
short-circuit-proof
range
with XTPAXCL Rated
30 Current
n [A]
Inherently
20 XTPR…D
16
Rated
short-circuit
breaking 10
cn
T echn ic al de ta ils
cc
capacity
range 6
XTPR…D
16... 25 32 40 50 63
Rated
Current
n [A]
95.7
49.7
TO TERMINALS 36.3
TO TERMINALS
45
209.2
XT SC 012 B B A
Design Coil Voltage
X = XT IEC Power Control A= 110V 50 Hz, 120V 60 Hz
B= 220V 50 Hz, 240V 60 Hz
C= 415V 50 Hz, 480V 60 Hz
Type D= 550V 50 Hz, 600V 60 Hz
SC = Manual Motor Controller — FVNR E= 208V 50 Hz
SR = Manual Motor Controller — FVR F= 230V 50 Hz
FC = Manual Motor Controller, UL 508 Type F — FVNR G= 190V 50 Hz, 220V 60 Hz
FR = Manual Motor Controller, UL 508 Type F — FVR H= 240V 50 Hz, 277V 60 Hz
L= 380V 50 Hz, 440V 60 Hz
N= 400V 50 Hz
Rated Current of MMP P= 380V 60 Hz
R= 12V 50/60 Hz
B-Frame D-Frame T= 24V 50/60 Hz
P16 = 0.16A 016 = 40A U= 24V 50 Hz
P25 = 0.25A 025 = 58A W= 42V 50 Hz, 48V 60 Hz
P40 = 0.40A 032 = 60A Y= 48V 50 Hz
P63 = 0.63A 040 = 16A AD = 120V DC
001 = 1A 050 = 20A BD = 220V DC
1P6 = 1.6A 058 = 25A RD = 12V DC
2P5 = 2.5A 060 = 32A TD = 24V DC
004 = 4A WD = 48V DC
6P3 = 6.3A
010 = 10A
Frame Size — Contactor
012 = 12A
016 = 16A B = 45 mm, 7 to 15A
020 = 20A C = 45 mm, 18 to 32A
025 = 25A D = 55 mm, 40 to 65A
032 = 32A
T echn ic al de ta ils
What is it?
The International Electrotechnical Commission (IEC) developed short circuit performance criteria for contactors and starters
called Type 1 coordination and Type 2 coordination. This defines motor controller protection levels following a short circuit
fault. In order to achieve this performance, the combination of a motor controller (contactor or starter) and short circuit
protective device (manual motor protector, circuit breaker or fuse) must meet the following criteria as specified by IEC 60947-
4-1 — Low voltage switchgear and controlgear — Part 4-1: Contactors and motor-starters — Electromechanical contactors and
motor-starters:
Type 1 Coordination requires that under short circuit conditions, the contactor or starter shall cause no danger to persons or
installation and may not be suitable for further service without repair and replacement of parts.
In this case, significant damage is allowed to the contactor/starter (e.g. contact welding, burning, or disintegration) and the
overload relay (e.g. component harm or heater element burn-out).
Type 2 Coordination requires that under short circuit conditions, the contactor or starter shall cause no danger to persons or
installation and shall be suitable for further use. The risk of contact welding is recognized, in which case the manufacturer
shall indicate the measures to be taken as regards to the maintenance of the equipment.
In this case, the contactor/starter is able to continue use after the occurrence of a short circuit fault. Light contact burning or
tack welding may occur provided the contacts are easily separable.
Generally speaking, most users expect Type 2 protection in their applications. With certifying agencies varying from country-
to-country and continent-to-continent, users will sometimes mistakenly assume that Type 2 coordination has been achieved if
their motor branch circuit components are CE marked, UL Listed Type E or F and/or CSA Certified. This is not necessarily true.
At the forefront of Type 2 benefits comes the assurance that the device poses no threat of danger to the person or
installation. Furthermore, with increased emphasis placed on reducing downtime to increase productivity, proper application
and selection of motor branch circuit devices is more important than ever. By selecting the proper type of protection, the
working environment and employees can be protected against hazardous fault conditions and the performance of contactors
and overload relays in the branch circuit can be maximized.
Type 2 protection provides confidence that motor control components will be operable following a short circuit fault. This reusability
translates into hundreds or even thousands of pounds in savings due to reduced downtime and replacement costs.
TYPE 2 Coordination = Safety + Less Downtime =Pounds
Standard Fault Short Circuit Current Rating (Derived from UL 508): The minimum short circuit current, based on horsepower
rating, that a starter must be capable of withstanding in accordance with the applicable pass/fail criteria. Denoted as Ir by IEC
60947-4-1 and Icr by IEC 60947-6-2.
Manufacturers may also specify short circuit ratings exceeding the minimum ratings required by standards. UL and CSA refer
T echn ic al de ta ils
to these as the High-Available Fault Short Circuit Current Rating. IEC 60947-4-1 and 60947-6-2 refer to these ratings as Iq and
Ics respectively.
High-Available Fault Short Circuit Current Rating (Derived from UL 508): The short circuit current rating specified by the
manufacturer of a motor controller, which is greater than the standard short circuit current rating. The motor controller is capable
of withstanding the high-available short circuit current in accordance with the applicable pass/fail criteria. Denoted as Iq by IEC
60947-4-1 and Ics by IEC 60947-6-2.
Following is a summary of short circuit testing pass/fail criteria applicable to magnetically operated direct-on-line contactors
and starters. Standards should be referenced for exact wording and all specific pass/fail criteria. UL and IEC criteria are
summarized for standard and high-available short circuit currents. CSA criteria are summarized for high-available short circuit
currents.
Fault Current Fault current is successfully interrupted and no arcing to enclosure or proximity barrier is
indicated by an open ground wire or fuselink.
Enclosure No substantial damage to the enclosure. It may be deformed but it must be possible to open the door.
Live parts shall not be accessible.
Terminals and Conductors No damage to conductors or terminals. Conductors must not be separated from the terminals.
Contactor/Starter Housing No cracking or breaking of the contactor/starter housing that impairs the integrity of the mounting of live parts.
Short Circuit Protective Device The circuit breaker or switch must be capable of being operated manually.
(SCPD) SCPD is not separated from its mounting means. Fuses must not rupture.
Contactor/Starter Contacts Welding and complete Welding acceptable. Welding acceptable provided
disintegration acceptable. contacts can be easily separated.
Overload Relay Electronic overload relays must be Damage acceptable. No damage, tripping
operable; tripping characteristics characteristics must be verified.
must be verified (UL). Mechanical
overload relays may be damaged,
if so, device must include markings
indicating that (UL).
Contactor/Starter Operation May be inoperable. May be inoperable. Must be operable, verified by 10
operations after short circuit test.
Other No discharge of parts from No discharge of parts from No discharge of parts from
enclosure. No risk of fire. enclosure. Must pass 2X rated enclosure. Must pass 2X rated
voltage, 1000V minimum dielectric voltage, 1000V minimum dielectric
test. test.
T echn ic al de ta ils
Step 1: Determine the motor kW (single or three phase) or full load motor current from the motor nameplate.
Step 2: Verify the motor full load amps are less than or equal to the operational current (Ie) listed next to the kW in the table.
Step 3: Manual Motor Controllers (MMC): Read across the tables horizontally for catalogue numbers of the Manual Motor
Protector (MMP) and contactor (customer assembly) or pre-assembled Manual Motor
Controller.
Note: For certain kW ratings at 480V and 600V, a current limiter must be used to achieve the maximum Type 2 rating (shown in the following tables). Customers can either order the
MMP and Current Limit Contactors or an assembled MMC and current limiter.
Circuit breaker combination controllers: Read across the tables horizontally to determine the catalogue numbers of the
circuit breaker to be used in conjunction with the contactor and overload relay listed (customer assembly) or the pre-assem-
bled motor starter.
Fused combination controllers: Read across the tables horizontally to determine what amperage size fuse (customer to
specify brand) and the catalogue numbers of the contactor and overload relay or the pre-assembled motor starter.
500V Type 2 Coordination, Contactor and Overload Relay (Motor Starter) with Fused Disconnect
P Ie Iq Fuses Contactor Overload Relay Assembled Starter
(kW) (A) (kA) Class gG/gL Eaton Eaton Eaton
list number1) list number list number 1)
T echn ic al de ta ils
24V 24V T
480 – 500V 480 – 500V C
380 – 440V 380 – 440V L
42 – 48V 42 – 48V W
24 – 27V TD 1)
110 – 130V AD 1)
200 – 240V BD 1)
48 – 60V WD 1)
Frame L – N
110 – 250V 110 – 250V 110 – 250V A
250 – 500V 250 – 500V C
48 – 110V 48 – 110V 48 – 110V Y 1)
24 – 48V TD 1)
Frame P – R 220 – 250V 220 – 250V 250 – 500V B
1) With DC operation: Integrated diode-resistor combination, coil rating 2.6W.
2) Add suffix in place ofunderscore (_) to Eaton List number.
Printed in UK
Form No PG03407001U
June 2006