Venturi flumes
stainless steel version
To reach an accurate measurement result take
care on the following points:
n The Venturi can not be used in channels
where a flow stop or back flow is expected.
n The flume have to be installed horizontal.
(maximum allowed difference is 1,5 o/oo)
n The venturi must be installed exactly in line to
channel.
n On no flow condition, there should be no water
staying on the Venturi floor.
n Downstream the flume there shall be nothing
installed that obstruct the flow.
n The side walls of the channel, where the two
flume parts are installed, have to be vertical
n Upstream the flume (15 up to 20 x the channel
width) the flow of the water has not to be
obstructed. There shall be no hydraulic
disturbance e.g. curves, installations, jumps,
changes in the channel width etc.
When measuring flow by using a Venturi flume * Use ultrasonic units with temperature
and an ultrasonic measurement device, please compensation. Avoid direct sun light on the
note: t-comp of the transducer, or use separate
t-comp. It can be installed under a shadow
* The best position of the ultrasonic transducer roof.
is approx. 2 x the height of the flume side parts
upstream the flume. * For accuracy reasons, the distance between
maximum level and transducer should be as
* The transducer has to be installed 90° through small as possible. The minimum distance
the survice of the water. between transducer face and maximum level
must be 30cm.
j:\1_eng\venturi\db-a4.p65 9901
NIVUS GmbH n Im Taele 2 n 75031 Eppingen n Germany n Internet: www.nivus.de
Tel.: + 49(0)7262/9191 - 0 n Fax: + 49(0)7262/9191 - 29 n E-mail: info@nivus.de
Specifications
The different dimensions are based on the channel width and the flow that is expected.
The calculation of the Venturi flume is based on DIN 19559 standard part 2.
B = width of the inlet Wb = width of one SS Venturi part
b = throat width of the Venturi flume Wh = height of one SS Venturi part
le = throat length ls = upstream distance between sensor
R = radius and Venturi flume = 2 x Wh
L = over all length of the Venturi flume
Shipping accessories:
V4A-bolts FB 6/10. two Venturi parts, the channel wall and ground
On Venturi-type 150/... -250/... V4A DIN 96-screws have to be sealed by using silicon.
and dowels are provided.
After the installation the appearing joints between
Venturi flumes
Type overview for stainless steel Venturi flumes
Q/max V4A
type B mm Wh mm b mm L mm Le mm Is mm r mm
l/s Ø mm
150/15 7 150 150 57 600 300 300 450 1,5
200/20 15 200 200 100 790 400 400 600 1,5
200/30 25 200 300 100 1046 600 600 900 1,5
250/20 17 250 200 125 829 400 400 600 1,5
250/30 30 250 300 125 1092 600 600 900 1,5
Because of the small channel width, Venturi flumes type 150/.. up to 250/.. are shipped in one part.
They can be screwed directly on the channel ground.
300/20 20 300 200 150 865 400 400 600 1,5
300/30 40 300 300 150 1135 600 600 900 1,5
300/40 60 300 400 150 1400 800 800 1200 1,5
400/30 50 400 300 200 1212 600 600 900 1,5
400/40 85 400 400 200 1480 800 800 1200 1,5
400/50 110 400 500 200 1740 1000 1000 1500 2,0
400/60 150 400 600 200 1990 1200 1200 1800 2,0
500/30 60 500 300 250 1280 600 600 900 2,0
500/40 95 500 400 250 1560 800 800 1200 2,0
500/50 150 500 500 250 1825 1000 1000 1500 2,0
500/60 190 500 600 250 2085 1200 1200 1800 2,0
500/70 250 500 700 250 2340 1400 1400 2100 2,0
600/40 115 600 400 300 1630 800 800 1200 2,0
600/50 170 600 500 300 1950 1000 1000 1500 2,0
600/60 240 600 600 300 2170 1200 1200 1800 2,0
600/70 300 600 700 300 2430 1400 1400 2100 2,0
600/80 360 600 800 300 2685 1600 1600 2400 2,0
700/40 135 700 400 350 1700 800 800 1200 2,0
700/50 195 700 500 350 1980 1000 1000 1500 2,0
700/60 260 700 600 350 2250 1200 1200 1800 2,0
700/70 350 700 700 350 2515 1400 1400 2100 2,0
700/80 420 700 800 350 2775 1600 1600 2400 2,0
800/40 145 800 400 400 1765 800 800 1200 2,0
800/50 210 800 500 400 2050 1000 1000 1500 2,0
800/60 300 800 600 400 2325 1200 1200 1800 2,0
800/70 400 800 700 400 2595 1400 1400 2100 2,0
800/80 480 800 800 400 2860 1600 1600 2400 2,0
900/50 260 900 500 450 2115 1000 1000 1500 2,5
900/70 450 900 700 450 2670 1400 1400 2100 2,5
1000/50 280 1000 500 500 2180 1000 1000 1500 2,5
1000/70 500 1000 700 500 2745 1400 1400 2100 2,5
1100/70 550 1100 700 550 2815 1400 1400 2100 2,5
1200/70 600 1200 700 600 2885 1400 1400 2100 2,5
1300/70 650 1300 700 650 2950 1400 1400 2100 2,5
1400/70 700 1400 700 700 3010 1400 1400 2100 2,5
1500/70 750 1500 700 750 3150 1400 1400 2100 2,5
j:\1_eng\venturi\db-a4.p65 9900
Bold printed types are standard flumes! Other dimensions are available on request!
If the value of the throat dimension b is different to value in this table, a special Q/h breakpoint curve
can be calculated.
NIVUS GmbH n Im Taele 2 n 75031 Eppingen n Germany n Internet: www.nivus.de
Tel.: + 49(0)7262/9191 - 0 n Fax: + 49(0)7262/9191 - 29 n E-mail: info@nivus.de