                      EVERY
                      CASE
                      MATTERS
                      TO YOU.
                      EVERY
                      TOOL
                      MATTERS
                      TO US.
MARKET-LEADING
CATHETER
INNOVATION
ASPIRATION                            Export™ AP    GUIDE
CATHETERS                             catheter      CATHETERS
                                                                                       Sherpa NX™
                                                                                       catheter
                                                         Launcher™
                                                         catheter
                        Export Advance™
                        catheter
GLOBAL MARKET LEADER                                BUILT FROM THE BEST
Our guide and aspiration catheters feature the      DxTerity™ catheters harness the same technology
familiar feel and uniformly high performance that   and design innovations found in our market-leading
only a true market leader can deliver.              guide catheters.
      AS TODAY’S
      RECOGNIZED
      GLOBAL LEADER
      IN CATHETER
      TECHNOLOGY,
      WE DELIVER
      BREAKTHROUGH
      PERFORMANCE
      TO MORE
      PATIENTS
      WORLDWIDE.
                                                         Introducing
                                                         the DxTerity™
                                                         & DxTerity™ TRA
                                                         diagnostic
                                                         catheters
A COMPLETE SOLUTION                                   COMPREHENSIVE,
With a broad range of shapes and sizes, DxTerity™
                                                      HIGH-PERFORMANCE
catheters are suitable for a variety of approaches.
                                                      CATHETER PORTFOLIO
                                                      Today, our complete portfolio of guide, aspiration,
                                                      and diagnostic catheters delivers the performance
                                                      and versatility to take on the most challenging
                                                      procedures. Because every tool in the cath
                                                      lab matters.
THE FULL-WALL
TECHNOLOGY
ADVANTAGE
Proprietary market-leading construction process
improves performance where it matters.
                                     Proprietary extrusion process
Our InSlide™ polymer additive is     melts layers together.
incorporated into the outer layer.   Forms a solid shaft construction
Provides superior lubricity          to enhance overall catheter
for enhanced deliverability2         performance
HOW IT’S MADE
WHAT IT DOES
Full-Wall Technology is a proprietary extrusion process that
melts catheter layers together to form a solid shaft. This unique
construction process is applied from hub to tip — giving the
DxTerity™ diagnostic catheter performance advantages that
push past ordinary expectations: superior torque and lubricity
for precise manipulation and enhanced deliverability.1
                                     The innermost layer of the
                                     catheter shaft is formed over
                                     a removable core.
                                     Provides structural integrity
    Double-braid wire applied from                                   Based on bench test data comparing leading competitors.
                                                                     1
    hub to tip forms the backbone                                    Bench test data may not be indicative of clinical performance.
                                                                     Based on bench test data on file at Medtronic. Medtronic
    of the catheter shaft.
                                                                     2
                                                                     position paper on DxTerity™ deliverability impact. The lubricity
                                                                     bench test measures how much force is required to pull the
    Enhances strength, torque, and                                   catheter through two silicone pads while submerged in water at
                                                                     body temperature.
    kink resistance
Superior lubricity                                                                             LUBRICITY (gf)
for enhanced                                                                        Merit
                                                                                                                                                        585
deliverability3                                                       Performa™* Catheter
                                                                          Boston Scientific
                                                                          Expo™* Catheter                                                               578
                                                                                      Cordis
                                                                         Infiniti™* Catheter                                                            574
                                                     LOWER
                                                   IS BETTER
                                                    (less force                     Cordis
                                                     required)     Super Torque™* Catheter                                                             571
                                                                                  Terumo
                                                                    Optitorque™* Catheter                                                              555
                                                                          Boston Scientific
                                                                       Impulse™* Catheter                                                        478
Based on bench test data on file at Medtronic.
3
Medtronic position paper on DxTerity 		
deliverability impact. The lubricity bench test                                 Medtronic
                                                                                                                167
measures how much force is required to pull                            DxTerity™ Catheter
the catheter through two silicone pads while
submerged in water at body temperature.
At least 30% softer                                                                            SOFT TIP COMPRESSION (gf)
atraumatic tip4                                                                     Merit
                                                                      Performa™* Catheter                                                                     >3005
                                                                                    Cordis
                                                                   Super Torque™* Catheter                                                                    143
                                                                                      Cordis
                                                                         Infiniti™* Catheter                                         87
                                                     LOWER
                                                   IS BETTER
                                                    (less force                   Terumo
                                                     required)      Optitorque™* Catheter
                                                                                                                                79
                                                                          Boston Scientific
                                                                       Impulse™* Catheter                                     74
                                                                          Boston Scientific
                                                                          Expo™* Catheter                              56
Based on bench test data on file at Medtronic
4
generated on brands listed above. Soft tip bench
                                                                                Medtronic
test measures the force required to compress
the catheter tip.                                                      DxTerity™ Catheter
                                                                                                                39
Exceeded the limit of the force gauge (>300 gf).
5
Best-in-class                                                                                  STRAIGHT LINE TORQUE (in-oz)
torqueability                                                                    Medtronic
                                                                                                                                                             1.04
for precise                                                             DxTerity™ Catheter
manipulation6                                                                       Cordis
                                                                   Super Torque™* Catheter                                                0.89
                                                                                   Terumo
                                                                     Optitorque™* Catheter                                           0.87
                                                    HIGHER                            Cordis
                                                   IS BETTER
                                                                         Infiniti™* Catheter                                   0.84
                                                   (more torque
                                                   transmission)
                                                                                    Merit
                                                                      Performa™* Catheter                                     0.78
                                                                           Boston Scientific
                                                                        Impulse™* Catheter                             0.67
                                                                          Boston Scientific
Based on bench test data on file at Medtronic.
6
                                                                          Expo™* Catheter                       0.61
The torque bench test measures torque 		
transmission after 40 degree rotation.
MORE
WAYS
TO HELP
PATIENTS
DxTerity™ and DxTerity™ TRA catheters —
a complete diagnostic solution for both
radial and femoral procedures.
THE DxTerity™                                                                                  TRApease curve
TRA CATHETER —
ALL OF THE PERFORMANCE
ADVANTAGES OF THE DxTerity™                                                          Ultra curve
CATHETER, SPECIFICALLY
ADAPTED FOR RADIAL USE.7
5
                                                                            TRAnsformer curve
                          universal radial                              TRActive curve
                          curve shapes
                          to access both coronaries
                          without catheter exchange.8
                                                                     TRAcker curve
Based on preclinical data on file at Medtronic.
7
In porcine models. Based on preclinical data on file at Medtronic.
8
DxTerity™
Diagnostic Catheter
                                                                                                                                   InSlide™ polymer additive
                                                         Solid shaft construction for                                              for superior lubricity and
                                                         efficient torque and overall                                              enhanced deliverability
                                                         catheter performance
           Unique, ergonomic,
           winged hub makes for
           easy manipulation
                                                                                                                                        Double-braid wire
                                                                Soft, atraumatic,                                                       enhances strength,
                                                                radiopaque tip                                                          torque, and kink resistance
                                                                increases visibility
Market-leading technology improves
.
performance where it matters:
..
     Superior torque and lubricity for precise
     manipulation and enhanced deliverability9
     Optimized for both radial and femoral procedures10                                                          9
                                                                                                                      Based on bench test data comparing leading competitors. Bench
     Wide range of shapes and sizes                                                                              10
                                                                                                                      test data may not be indicative of clinical performance.
                                                                                                                      Based on preclinical data on file at Medtronic.
For further information, please call and/or consult
Medtronic at the toll-free numbers or websites listed.
Medtronic              LifeLine Customer Support
3576 Unocal Place      Tel: 877.526.7890
Santa Rosa, CA 95403   Tel: 763.526.7890
USA
Tel: 707.525.0111      Product Services                                                 ©2018 Medtronic. All rights reserved. Medtronic, Medtronic logo and Further, Together are
                       Tel: 888.283.7868                                                trademarks of Medtronic. ™* Third-party brands are trademarks of their respective owners.
                       Fax: 800.838.3103                                                All other brands are trademarks of a Medtronic company. For distribution only in the USA.
medtronic.com                                                                           Printed in USA. UC201606221aEN 8/18