0% found this document useful (0 votes)
118 views8 pages

NDT Magnetic Inspection Report

This document contains 3 magnetic inspection certificates issued by SARL INSPEC CND for ENAFOR #45. Each certificate details the inspection of a 9 5/8 inch item, listing the serial number, manufacturer, and inspection methods used. Visual and magnetic particle inspections were performed at points including hinges, bail arms, and handles. No relevant indications were found for any of the items inspected.

Uploaded by

Abdou Boucherit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
118 views8 pages

NDT Magnetic Inspection Report

This document contains 3 magnetic inspection certificates issued by SARL INSPEC CND for ENAFOR #45. Each certificate details the inspection of a 9 5/8 inch item, listing the serial number, manufacturer, and inspection methods used. Visual and magnetic particle inspections were performed at points including hinges, bail arms, and handles. No relevant indications were found for any of the items inspected.

Uploaded by

Abdou Boucherit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

SARL INSPEC CND Version:01

Société de prestations de services en Contrôle non Destructif


Inspection et Certification
Date :05/05/2022
Siège social : si-elhaoues . Hassi messaoud w d’Ouargla
IM PT 07-1 Tél/Fax : 029 79 31 58 E-mail : inspeccnd@gmail.com www,inspeccnd.com Page 1/1

MAGNETIC INSPECTION CERTIFICATE


Customer : ENAFOR # 45 Certif.# : NDT/MT/ 023 /2023
Adress : HMD Issue Date : 28/11/2022
Work location : Ourhoud Due Date : 27/05/2023
Work Order : 00010 Specification : ASTM E709
API RP 8B

METHODS USED
Fluorescent mag. Particle : Visual Inspection : X Pie-field indicator test : Magnaflux
Contrast with magnetic ink : X Settling test (ml/100ml) : 0,3 Field direction : Longitudinal
Dry Magnetic Particle : Black light :

AC YOKE : X N°: 2022/3PY Calibration date 12/11/2022


Coil : N°: Calibration date

ITEM DESCRIPTION

Description Singl Joint


SERIAL N° 990200010654
SIZE (INCH) 9 5/8"
CAPACITY /
MANUFACTURE /

Tested Points Description:


A -Hanges
B -Left Bail Arm
C -Right Bail Arm
D -Handles

We have carried out a Visual inspection and Magnetic Particle Inspection on the Item mentioned here above
and was found : OK

Qualification: Comments:
Inspector : Result :

No Revelant Indecatio Found At The Tim


Inspection
SARL INSPEC CND Version:01
Société de prestations de services en Contrôle non Destructif
Inspection et Certification
Date :05/05/2022
Siège social : si-elhaoues . Hassi messaoud w d’Ouargla
IM PT 07-1 Tél/Fax : 029 79 31 58 E-mail : inspeccnd@gmail.com www,inspeccnd.com Page 1/1

MAGNETIC INSPECTION CERTIFICATE


Customer : ENAFOR # 45 Certif.# : NDT/MT/ 024 /2023
Adress : HMD Issue Date : 28/11/2022
Work location : Ourhoud Due Date : 27/05/2023
Work Order : 00010 Specification : ASTM E709
API RP 8B

METHODS USED
Fluorescent mag. Particle : Visual Inspection : X Pie-field indicator test : Magnaflux
Contrast with magnetic ink : X Settling test (ml/100ml) : 0,3 Field direction : Longitudinal
Dry Magnetic Particle : Black light :

AC YOKE : X N°: 2022/3PY Calibration date 12/11/2022


Coil : N°: Calibration date

ITEM DESCRIPTION

Description Singl Joint


SERIAL N° 990200012410
SIZE (INCH) 9 5/8"
CAPACITY /
MANUFACTURE /

Tested Points Description:


A -Hanges
B -Left Bail Arm
C -Right Bail Arm
D -Handles

We have carried out a Visual inspection and Magnetic Particle Inspection on the Item mentioned here above
and was found : OK

Qualification: Comments:
Inspector : Result :

No Revelant Indecatio Found At The Tim


Inspection
SARL INSPEC CND Version:01
Société de prestations de services en Contrôle non Destructif
Inspection et Certification
Date :05/05/2022
Siège social : si-elhaoues . Hassi messaoud w d’Ouargla
IM PT 07-1 Tél/Fax : 029 79 31 58 E-mail : inspeccnd@gmail.com www,inspeccnd.com Page 1/1

MAGNETIC INSPECTION CERTIFICATE


Customer : ENAFOR # 45 Certif.# : NDT/MT/ 025 /2023
Adress : HMD Issue Date : 28/11/2022
Work location : Ourhoud Due Date : 27/05/2023
Work Order : 00010 Specification : ASTM E709
API RP 8B

METHODS USED
Fluorescent mag. Particle : Visual Inspection : X Pie-field indicator test : Magnaflux
Contrast with magnetic ink : X Settling test (ml/100ml) : 0,3 Field direction : Longitudinal
Dry Magnetic Particle : Black light :

AC YOKE : X N°: 2022/3PY Calibration date 12/11/2022


Coil : N°: Calibration date

ITEM DESCRIPTION

Description Singl Joint


SERIAL N° 990200019274
SIZE (INCH) 9 5/8"
CAPACITY /
MANUFACTURE NOV

Tested Points Description:


A -Hanges
B -Left Bail Arm
C -Right Bail Arm
D -Handles

We have carried out a Visual inspection and Magnetic Particle Inspection on the Item mentioned here above
and was found : OK

Qualification: Comments:
Inspector : Result :

No Revelant Indecatio Found At The Tim


Inspection
SARL INSPEC CND Version:01
Société de prestations de services en Contrôle non Destructif
Inspection et Certification
Date :05/05/2022
Siège social : si-elhaoues . Hassi messaoud w d’Ouargla
IM PT 07-1 Tél/Fax : 029 79 31 58 E-mail : inspeccnd@gmail.com www,inspeccnd.com Page 1/1

MAGNETIC INSPECTION CERTIFICATE


Customer : ENAFOR # 45 Certif.# : NDT/MT/ 026 /2023
Adress : HMD Issue Date : 28/11/2022
Work location : Ourhoud Due Date : 27/05/2023
Work Order : 00010 Specification : ASTM E709
API RP 8B

METHODS USED
Fluorescent mag. Particle : Visual Inspection : X Pie-field indicator test : Magnaflux
Contrast with magnetic ink : X Settling test (ml/100ml) : 0,3 Field direction : Longitudinal
Dry Magnetic Particle : Black light :

AC YOKE : X N°: 2022/3PY Calibration date 12/11/2022


Coil : N°: Calibration date

ITEM DESCRIPTION

Description Singl Joint


SERIAL N° 990200010652
SIZE (INCH) 13 3/8"
CAPACITY /
MANUFACTURE NOV

Tested Points Description:


A -Hanges
B -Left Bail Arm
C -Right Bail Arm
D -Handles

We have carried out a Visual inspection and Magnetic Particle Inspection on the Item mentioned here above
and was found : OK

Qualification: Comments:
Inspector : Result :

No Revelant Indecatio Found At The Tim


Inspection
SARL INSPEC CND Version:01
Société de prestations de services en Contrôle non Destructif
Inspection et Certification
Date :05/05/2022
Siège social : si-elhaoues . Hassi messaoud w d’Ouargla
IM PT 07-1 Tél/Fax : 029 79 31 58 E-mail : inspeccnd@gmail.com www,inspeccnd.com Page 1/1

MAGNETIC INSPECTION CERTIFICATE


Customer : ENAFOR # 45 Certif.# : NDT/MT/ 027 /2023
Adress : HMD Issue Date : 28/11/2022
Work location : Ourhoud Due Date : 27/05/2023
Work Order : 00010 Specification : ASTM E709
API RP 8B

METHODS USED
Fluorescent mag. Particle : Visual Inspection : X Pie-field indicator test : Magnaflux
Contrast with magnetic ink : X Settling test (ml/100ml) : 0,3 Field direction : Longitudinal
Dry Magnetic Particle : Black light :

AC YOKE : X N°: 2022/3PY Calibration date 12/11/2022


Coil : N°: Calibration date

ITEM DESCRIPTION

Description Singl Joint


SERIAL N° 990200012032
SIZE (INCH) 13 3/8"
CAPACITY /
MANUFACTURE NOV

Tested Points Description:


A -Hanges
B -Left Bail Arm
C -Right Bail Arm
D -Handles

We have carried out a Visual inspection and Magnetic Particle Inspection on the Item mentioned here above
and was found : OK

Qualification: Comments:
Inspector : Result :

No Revelant Indecatio Found At The Tim


Inspection
SARL INSPEC CND Version:01
Société de prestations de services en Contrôle non Destructif
Inspection et Certification
Date :05/05/2022
Siège social : si-elhaoues . Hassi messaoud w d’Ouargla
IM PT 07-1 Tél/Fax : 029 79 31 58 E-mail : inspeccnd@gmail.com www,inspeccnd.com Page 1/1

MAGNETIC INSPECTION CERTIFICATE


Customer : ENAFOR # 45 Certif.# : NDT/MT/ 028 /2023
Adress : HMD Issue Date : 28/11/2022
Work location : Ourhoud Due Date : 27/05/2023
Work Order : 00010 Specification : ASTM E709
API RP 8B

METHODS USED
Fluorescent mag. Particle : Visual Inspection : X Pie-field indicator test : Magnaflux
Contrast with magnetic ink : X Settling test (ml/100ml) : 0,3 Field direction : Longitudinal
Dry Magnetic Particle : Black light :

AC YOKE : X N°: 2022/3PY Calibration date 12/11/2022


Coil : N°: Calibration date

ITEM DESCRIPTION

Description Singl Joint


SERIAL N° 990200012032
SIZE (INCH) 18 5/8"
CAPACITY /
MANUFACTURE NOV

Tested Points Description:


A -Hanges
B -Left Bail Arm
C -Right Bail Arm
D -Handles

We have carried out a Visual inspection and Magnetic Particle Inspection on the Item mentioned here above
and was found : OK

Qualification: Comments:
Inspector : Result :

No Revelant Indecatio Found At The Tim


Inspection
SARL INSPEC CND Version:01
Société de prestations de services en Contrôle non Destructif
Inspection et Certification
Date :05/05/2022
Siège social : si-elhaoues . Hassi messaoud w d’Ouargla
IM PT 07-1 Tél/Fax : 029 79 31 58 E-mail : inspeccnd@gmail.com www,inspeccnd.com Page 1/1

MAGNETIC INSPECTION CERTIFICATE


Customer : ENAFOR # 45 Certif.# : NDT/MT/ 029 /2023
Adress : HMD Issue Date : 28/11/2022
Work location : Ourhoud Due Date : 27/05/2023
Work Order : 00010 Specification : ASTM E709
API RP 8B

METHODS USED
Fluorescent mag. Particle : Visual Inspection : X Pie-field indicator test : Magnaflux
Contrast with magnetic ink : X Settling test (ml/100ml) : 0,3 Field direction : Longitudinal
Dry Magnetic Particle : Black light :

AC YOKE : X N°: 2022/3PY Calibration date 12/11/2022


Coil : N°: Calibration date

ITEM DESCRIPTION

Description Singl Joint


SERIAL N° 990200010656
SIZE (INCH) 4 1/2"
CAPACITY 4T
MANUFACTURE NOV

Tested Points Description:


A -Hanges
B -Left Bail Arm
C -Right Bail Arm
D -Handles

We have carried out a Visual inspection and Magnetic Particle Inspection on the Item mentioned here above
and was found : OK

Qualification: Comments:
Inspector : Result :

No Revelant Indecatio Found At The Tim


Inspection
SARL INSPEC CND Version:01
Société de prestations de services en Contrôle non Destructif
Inspection et Certification
Date :05/05/2022
Siège social : si-elhaoues . Hassi messaoud w d’Ouargla
IM PT 07-1 Tél/Fax : 029 79 31 58 E-mail : inspeccnd@gmail.com www,inspeccnd.com Page 1/1

MAGNETIC INSPECTION CERTIFICATE


Customer : ENAFOR # 45 Certif.# : NDT/MT/ 030 /2023
Adress : HMD Issue Date : 28/11/2022
Work location : Ourhoud Due Date : 27/05/2023
Work Order : 00010 Specification : ASTM E709
API RP 8B

METHODS USED
Fluorescent mag. Particle : Visual Inspection : X Pie-field indicator test : Magnaflux
Contrast with magnetic ink : X Settling test (ml/100ml) : 0,3 Field direction : Longitudinal
Dry Magnetic Particle : Black light :

AC YOKE : X N°: 2022/3PY Calibration date 12/11/2022


Coil : N°: Calibration date

ITEM DESCRIPTION

Description Singl Joint


SERIAL N° 990200012411
SIZE (INCH) 4 1/2"
CAPACITY 4T
MANUFACTURE BJ

Tested Points Description:


A -Hanges
B -Left Bail Arm
C -Right Bail Arm
D -Handles

We have carried out a Visual inspection and Magnetic Particle Inspection on the Item mentioned here above
and was found : CRACKED

Qualification: Comments:
Inspector : Result :

Rejecte