C15 ACERT®                                      320-455 ekW — 60 Hz
1800 rpm
                                                               Diesel Oilfield                                 365-455 kVA — 50 Hz
                                                               Generator Set                                              1500 rpm
                                                               CAT® ENGINE SPECIFICATIONS
                                                               In-Line 6, 4-Stroke-Cycle water-cooled diesel
                                                               Bore.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137.2 mm (5.4 in.)
                                                               Stroke. . . . . . . . . . . . . . . . . . . . . . . . . . . . 171.4 mm (6.75 in.)
                                                               Displacement.. . . . . . . . . . . . . . . . . . . 15.2 L (927.56 cu. in.)
                                                               Compression Ratio.. . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.1:1
                                                               Aspiration.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ATAAC
                                                               Fuel System.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MEUI
                                                               Governor Type.. . . . . . . . Cat® ADEM™ A4 control system
                                                               Package Weight (estimated) . . . . . . . 4760 kg (10,500 lb.)
                                                               Caterpillar is leading the power generation marketplace
Image shown may
not reflect actual package.
                                                               with power solutions engineered to deliver unmatched
                                                               flexibility, expandability, reliability, and cost-effectiveness.
FEATURES
Ready to Run                                                   Cat C15 ACERT® ATAAC Diesel Engine
• Shipped from the factory complete and ready to run           • Utilizes ACERT Technology
                                                               • Reliable, rugged, durable design
Fuel/Emissions Strategy
                                                               • Field-proven in thousands of applications worldwide
• U.S. EPA Tier 2 or 3 and EU and China Stage 2
                                                               • Four-stroke diesel engine combines consistent
   non-road compliant
                                                                  performance and excellent fuel economy with minimum
Full Range of Attachments                                         weight
• Wide range of bolt-on system expansion attachments,         • Electronic engine control
   factory designed and tested
                                                               Cat Generator
Single-Source Supplier                                         • Designed to match performance and output
• Fully prototype-tested with certified torsional vibration      characteristics of Cat diesel engines
   analysis available                                          • 2/3 pitch
                                                               • UL 1446 Recognized Class H Insulation
Worldwide Product Support
• Cat dealers provide extensive post-sale support             Cat EMCP 3 Control Panel
   including maintenance and repair agreements.                • EMCP 3.1 offers basic engine/generator monitoring,
• Cat dealers fill 99.7 percent of parts orders within 24        metering, and protection.
   hours.                                                      • Segregated low voltage (AC/DC) accessory box
• Cat dealers have over 2,100 dealer branch stores               provides single point access to accessory connections
   operating in 200 countries.                                 • Panel lights
• The Cat S•O•SSM program cost-effectively detects
                                                               Web Site
  internal engine component condition, even the presence
                                                               For all your petroleum power requirements, visit
  of unwanted fluids and combustion by-products.
                                                               www.catoilandgas.cat.com.
LEHW0010-01		                                                                                                                          Page 1 of 4
                                                     C15 ACERT DIESEL OILFIELD GENERATOR SET
                                                                                                 320-455 ekW — 60 Hz, 1800 rpm
                                                                                                 365-455 kVA — 50 Hz, 1500 rpm
STANDARD EQUIPMENT                                         OPTIONAL EQUIPMENT (continued)
Air Inlet System                                           Generator
• Heavy-duty air filter                                    • Permanent magnet excitation
Cooling System                                             • Oversize and premium generators
• Radiator package mounted (50° C)                         • Anti-condensation space heaters available with
• Coolant drain line with valve at edge of base              permanent magnet excitation generators
• Coolant level sensor                                     Power Termination
• Fan and belt guards                                      • Top and bottom power cable entry
• Coolant level sight gauge                                Starting/Charging System
• Cat Extended Life Coolant                                • Jacket water heater with shutoff valves
Exhaust System                                             • Battery disconnect switch
• Dry exhaust manifold                                     • Battery rack with heavy duty batteries
• Flanged faced outlets
• Stainless steel flex with split-cuff connection
Fuel System                                                SPECIFICATIONS
• Primary fuel filter with integral water separator
• Secondary fuel filters                                   Cat Generator
• Fuel priming pump                                        Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480 V
• Flex fuel lines                                          Excitation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Self excited
Generator                                                  Pitch.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.6667
• SR4B brushless, single-bearing, self-excited             Number of poles.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
• Class H insulation                                       Number of bearings.. . . . . . . . . . . . . . . . . . . . . . . . . . . Single
• Random wound                                             Insulation.. . . . . . . . . . . . . . . . UL 1446 Recognized Class H
• IP23 protection                                            ...............................with tropicalization and antiabrasion
• CDVR 3-phase sensing with selectable volts/Hz            IP Rating.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drip Proof IP23
• 3 sensing CTs and one droop CT                           Alignment.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pilot Shaft
• Coastal protection
                                                           Overspeed capability.. . . . . . . . . . . . . . . . . . . 125% of rated
Power Termination                                          Wave form deviation (line-to-line).. . . . . . . . . . . . . . . . . . 2%
• RH extended cable access box
                                                           Voltage regulator.. . . . . . . . . . . . . . . . 3-phase sensing with
Governor                                                      ......................................................... selectable volts/Hz
• ADEM A4
                                                           Voltage regulation.. . . . . . Less than ± 1/2% (steady state)
Lube System                                                   .................... Less than ± 1/2% (with 3% speed change)
• Deep sump (60 L) — 500-hour service interval
                                                           Harmonic Distortion.. . . . . . . . . . . . . . . . . . . . Less than 5%
• High efficiency oil filter
• Oil drain valves
• Fumes disposal                                           Cat EMCP 3 Control Panel
• Gear-type lube oil pump                                  • EMCP 3.1
Mounting System                                            • NEMA 1, IP23 enclosure
• Steel base frame (skidable)                              • Run/Auto/Stop control
• Linear vibration isolation — seismic zone 4              • True RMS metering, 3-phase
Starting/Charging System                                   • Speed adjust
• 24-volt starting motor                                   • Vandal cover (option)
• 45-amp charging alternator                               • Voltage adjust
• Battery rack                                             • Digital indication for:
General                                                      - rpm
• Paint — Caterpillar yellow except rails and radiators      - Operating hours
  (gloss black)                                              - Oil pressure
• Flywheel and flywheel housing — SAE No. 1                  - Coolant temperature
• Vibration damper with pulley                               - System DC volts
• Engine lifting eyes                                        - L-L volts, L-N volts, phase amps, Hz
                                                             - ekW, kVA, kVAR, kW-hr, % kW, PF, (EMCP 3.2/3.3)
OPTIONAL EQUIPMENT                                         • Shutdowns with common indicating light for:
                                                             - Low oil pressure
Air Inlet System                                             - High coolant temperature
• Precleaner                                                 - Low coolant level
Exhaust System                                               - Overspeed
• Mufflers                                                   - Emergency stop
• Manifold and turbocharger guards
                                                             - Failure to start (overcrank)
• Elbows
LEHW0010-01		                                                                                                                             Page 2 of 4
                                                          C15 ACERT DIESEL OILFIELD GENERATOR SET
                                                                                            320-455 ekW — 60 Hz, 1800 rpm
                                                                                            365-455 kVA — 50 Hz, 1500 rpm
C15 ACERT OILFIELD GENERATOR SET PACKAGES
		                                               60 Hz — Standard                                    50 Hz — Standard
     ekW Rating                   320            365            410            455              292                364
     kVA Rating                   400            455            515            570              365                455
     rpm                         1800           1800           1800           1800             1500                1500
     Emissions                EPA Tier 3     EPA Tier 3     EPA Tier 3     EPA Tier 2    EU/China Stage 2 EU/China Stage 2
     Rated PF                     0.8            0.8            0.8            0.8              0.8                 0.8
     Temperature Rise    2
                                105° C         105° C         105° C         105° C           105° C              105° C
     Tilt Requirements         5° Static      5° Static       5° Static     5° Static         5° Static          5° Static
     Insulation Class              H              H              H              H                H                   H
     Overload                 50% / 2 min.   50% / 2 min.   50% / 2 min. 50% / 2 min.       50% / 2 min.       50% / 2 min.
     Excitation (PM option)       SE             SE             SE             SE               SE                  SE
     Voltage                      480            480            480            480              400                400
     Voltage Regulator          CDVR           CDVR            CDVR          CDVR              CDVR               CDVR
     Configuration               1-Brg          1-Brg          1-Brg          1-Brg            1-Brg               1-Brg
     Coastal Protection           Yes            Yes            Yes            Yes              Yes                Yes
     Space Heater                Opt.           Opt.            Opt.          Opt.              Opt.               Opt.
     Construction                 RW             RW             RW             RW               RW                 RW
     Frame Size                   449            450            499            499              450                499
Generator Terminal Box
Terminal box shall be standard with terminals on the right side, top entry or rear depending on size. Normal cable entrance
shall be from the top.
1
    Ambient capability at 1000 m (3281 ft) above sea level. For ambient capability at other altitudes, consult your Cat dealer.
    Air flow restriction (system) is added to existing restriction from factory.
2
 Generator temperature rise is based on a 40° C (104° F) ambient per NEMA MG1-32.
For additional generator ratings contact your local dealer.
LEHW0010-01		                                                                                                            Page 3 of 4
                                                                C15 ACERT DIESEL OILFIELD GENERATOR SET
                                                                                                              320-455 ekW — 60 Hz, 1800 rpm
                                                                                                              365-455 kVA — 50 Hz, 1500 rpm
INSTALLATION DRAWINGS
              Front View                                                                   Left Side View
                                                                                 2036.5 mm
                                                                                  (80.2 in.)
                                                     2110.2 mm
                                                     (83.077 in.)
                                                                                                                                           1736.7 mm
                                                                                                                                            (68.4 in.)
1358.3 mm
 (53.5 in.)
                    1320-1524 mm                                                                 3518 mm
                    (52.0-60.0 in.)                                                             (138.5 in.)
                    Note: Package dimensions may change depending on generator arrangement selection.
                                                             Package Dimensions
                                 Length                                    3518 mm                 138.5 in.
                                 Width                                 1320-1524 mm             52.0-60.0 in.
                                 Height                                  2110.2 mm                83.077 in.
                                 Weight (estimated)                        4760 kg                10,500 lb.
RATING DEFINITIONS AND CONDITIONS
Meets or Exceeds International Specifications: AS1359,                         Ratings are based on SAE J1995 standard conditions.
AS2789, CSA, EGSA101P,IEC60034, ISO3046, ISO8528,                              These ratings also apply at ISO3046 standard conditions.
NEMA MG 1-32, UL508, 72/23/EEC, 89/336/EEC, 98/37/                             Fuel rates are based on fuel oil of 35° API [16° C
EEC.                                                                           (60° F)] gravity having an LHV of 82 780 kJ/kg
                                                                               (18,390 Btu/lb) when used at 29° C (85° F) and weighing
Prime output available with varying load for an
                                                                               838.9 g/liter (7.001 lbs/U.S. gal.). Additional ratings may be
unlimited time. Prime power in accordance with ISO8528.
                                                                               available for specific customer requirements. Consult your
10 percent overload power in accordance with ISO3046,
                                                                               Caterpillar representative for details.
AS2789, and BS5514. Prime ambient temperatures
shown indicate a coolant top tank temperature just below
shutdown at 100 percent load.
        Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication.
         CAT, CATERPILLAR, their respective logos, S•O•S, ACERT, ADEM, “Caterpillar Yellow,” the “Power Edge” trade dress as well as
               corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
		                                                                                                                                  ©2009 Caterpillar
LEHW0010-01 (4-09)                                                                                                                  All rights reserved.