QT-99 Instruction Manual
QT-99 Instruction Manual
QUARTZ TESTER
    QT-99
  INSTRUCTION MANUAL
                      SEIKO QUARTZ TESTER QT-99
The SEIKO Quartz Tester QT-99 is the high-performance digital daily rate
counter using a full-scale micro computer. It can measure and immediately
indicate digitally with high accuracy and reliability the daily rate of high·
precision electronic timepieces such as quartz watches and tuning fork
watches.
The computer undertakes the measurement, data processing, and display of
results according to the .various, complicated routines stored in a built-in
memory, making it possible to measure special watches that have so far
defied the measurement by the conventional quartz testers.
T he crystal oscillator used provides a highly stabilized reference frequency
with an extremely high accuracy of 10-8 .
Your QT-99 works with solid-state reliability and stability and is very easy
to handle.
CONTENTS
                                            _,_
DESIGNATION AND EXPLANATION OF CONTROL PANEL
FUNCTIONS
•   Read the description of control panel functions while referring to the layout of func-
    t ions shown below.
® ® ©@ ®
: :.
®© Q) Q) ® ®
@ ® @ ®®
                                          - 2-
GETTING ACQUAINTED
                                     - 3-
PRINCIPAL FUNCTIONS AND FEATURES
• Provided with a computer-aided watch measuring system, QT-99 assures
  you of easy operation and reliable results.
• The crystal oscillator that provides a reference signal for measurement is of
  an oven-controlled type, and ensures highly accurate, stabilized measure-
  ment.
• The daily rate can be automatically measured by placing the watch on the
  microphone with the automatic frequency selection device.
  Almost every watch can be measured in a single process; all that is needed
  for measurement is to load it on a microphone.
• The measured daily rate is displayed in four digits (max.) together with a
  (+) sign for gain and a (- ) sign for loss.
• The measuring time can be set in eight steps-4, 6, 8, 10, 12, 30, 60 sec.
  and 120 sec.- from which to choose the best. In the case of channel
  setting, the optimum gate times can be selected out of the whole-number-
  ed seconds within the range of 2 to 120 sec. to meet the setup of a given
  watch. Four channels are provided, and the memory data can be added
  or changed.
• The display unit is 0.01 sec./day or 0.1 sec./day (by rounding off the
  fractions to three or two decimal places. The measuring range is within
  ±19.99 sec./day or within ±199.9 sec./day.
• During measurement, the input indicator will flash in tune with the watch
  signal detected.
• The measurement starts automatically as soon as the watch is set on the
  microphone, and continuously until it is removed.
• You can monitor the watch signal detecting condit ions by earphone to
  locate the watch at the best position on the microphone, making it feasible
  to measure a watch of feeble signal. In addition, the optimum volume at
  which the monitoring is made can be maintained as it is not affected by
  the change in the measuring level.
• OT-99 uses the special circuit which detects the watch signal most accu-
  rately. Read the value after measuring twice or three t imes, which indicate
  the accurate daily rate. So it is not necessary to take an average of values
  obtained by several measurements.
• When the watch signal is dead or when the daily rate is in excess of the
  measuring range, no display will be indicated, eliminating the deceptive
  readings as in the overflow lamp system.
• The 7-segment display is wide, bright and legible, and can be read even
   from a distance.
• The DM-1 microphone is both used as Electro-magnetic and Electric-field
  detection microphone because of its high performance, and it can be used
  for measuring the daily rate of both analogue and digital electronic watches.
• Various types of microphones for Timegrapher can also be used with
  GT-99.                                -4-
DESCRIPTION OF CONTROL PANEL FUNCTIONS
                                     - 5-
(I)   GATE TIME/CHANNEL setting switch
      This switch is used for setting the gate time or the channel.
      When the measurement is to be made with this switch set at GATE
      TIME, it is necessary to set the watch selection switch (E) and the watch
      signal divider selector switch (P) correctly. As soon as this switch is
      changed over, the measuring circuit will be reset.
      When the switch is set at CHANNEL, all the work for measurement will
      be undertaken automatically by the computer so the watch selection
      switch (E) and the watch signal divider selector switch (P) are not used.
(J)   LEVEL adjuster (with switch)
      Used for adjusting the watch signal level.
      For almost all watches, the AUTO position (Turn it counterclockwise
      until a click is heard.) will do for measurement. Except at the AUTO
      position, the knob will increase the signal level when it is turned clock-
      wise. Turn the knob clockwise if a feeble signal is to be measured. If the
      signal is too strong as you will experience in the measurement of some
      specific clocks, turn the knob counterclockwise to moderate its level.
      The volume of the earphone is not affected by the adjustment of this
      knob.
(K) INPUT jack
      Used for connecting the microphone.
(L)   Electro-magnetic/Electric-field detection microphone DM-1
      A microphone for exclusive use with electronic watches of both analogue
      and digital types.
(M) Mark for placing watch
      A mark showing the best position for the detection of watch signal.
      Where a liquid crystal watch (LCD) is to be measured, place it on the
      microphone with its display side (glass) down on this mark.
(N) Electro-magnetic/Electric-field detection chanQeover switch and battery ·
      switch
      This switch serves to change the detection m~de from one to another
      and also to turn on and off the built-in battery circuit. For the measure-
      ment of liquid crystal watch (LCD), set the switch at LCD ON, and the
      battery circuit will be turned on to permit the measurement in the elec-
      tric-field detection mode.
      When measuring the analogue watch or light-emitting diode watch (LED)
      or when the microphone is not used, set the switch at STEP-SWEEP-
      LED, and the battery circuit will be turned off to conserve battery life.
(0) Crystal oscillator check terminal
      A 4.32 MHz signal is generated at this terminal. Used to check the crystal
      oscillator of QT-99 for repair.
                                        - 6-
(Pl   Watch signal divider selector switch
      This is used for measuring those watches whose output is of a special
      frequency. If the watch output frequency is of an odd number (e.g.,
      361 Hz) or of a mixed number (e.g., 170 2/3, 256 1/2, 361 1/3 Hz), set
      the switch to the corresponding position. The watches of these fre-
      quencies are of old-fashioned type, and will rarely be met with. Usually,
      therefore, the switch is to be kept at GENERAL (even numbered fre-
      quency position) . If the switch is set at +N/3, the measurement will not
      be made unless the gate time is set at a multiple of 3 sec.
      When the channel is used for measurement, this switch is not used.
(0) FUSE holder
      This fuse holder has a voltage setting switch. Be sure to use only a 1A
      fuse. As the voltage setting range is from 100V to 240V, it can cover any
      home outlet voltage abroad.
      Before using QT-99, be sure to set the fuse holder at the outlet voltage
      available. If the power cord is plugged into the outlet with the power
      switch held on, the fuse may be blown. But this is not a malfunction.
      The voltage settings available are as follows.
             100V, 110V, 120V,200V,220V,240V
(R) Grounding terminal screw
      For noise reduction and operator's safety, be sure to connect a ground-
      ing cable (furnished as one of standard accessories) to this screw. The
      QT-99 will be grounded. Note that the noise may be increased all the
      more if the cable is grounded improperly. Under any circumstances, do
      not connect the grounding cable to a gas pipe.
(S)   Power cord connector
      This is to insert the connector plug of the power cord.
                                      - 7-
FUNCTION OF ELECTRO-MAGNETIC/ELECTRIC-FIELD
DETECTION MICROPHONE DM-1
SWITCH OPERATION
The switch (N) at the left of the microphone is for changeover to and from
the electro-magnetic and the electric-field detection function.
When it is pushed to the LCD ON position, the battery will be activated, and
the microphone will assume the electric-field detection function with which
the daily rate of the LCD watch can be measured.
When it is pushed to the STEP-SWEEP-LED position, the battery will be turn-
ed off and the electro-magnetic function will start to measure the daily rate
of the analogue and the LED watches.
When the microphone is not used, keep the switch at STEP-SWEEP-LED posi-
tion to conserve battery life.
HOW TO OPERATE
•   Analogue electronic watch
    Set the switch (NI at STEP-SWEEP-LED position (electro-magnetic field
    detection mode). Place the watch at or around the mark @ (M) (appearing
    at the center of the microphone) with its dial facing you or upward.
    See Photos 1 and 2. (Select the photo 1 or 2 position whichever produces
    the higher sound level in the earphone.)
•   Liquid crystal watch (LCD)
    Set the switch (NI at LCD ON position (electric-field detection mode).
    Place the watch on the microphone with its liquid crystal display to face
    the mark @ (M) at the center of the microphone. (Namely, the case back
    will face you.)
    See Photo 3. The best way for measurement is to let the watch display the
    date digits which will stay unchanged during measurement.
    (Place the watch with its crown up or down whichever produces the higher
    sound level in the earphone.)
    Note: If the liquid crystal panel is smeared with sweat or oil, the m icrophone cannot
          pick up the watch signal. Do not put the watch in a vinyl bag when its daily
          rate is measu red.
                                           -8-
•   Light-emitting diode (LED)
    watch
    Set the switch (N) at STEP-
    SWEEP-LED position (electro·
    magnetic f ield detection mode).
    Measure the watch by activating
    its display in some way or other.
    (Ex. Hold down the button with
    an adhesive tape.) The best way
    for measurement is to let the
    watch display the date digits
    which will stay unchanged dur-             Photo 1
    ing measurement.                                     Fig. 1
    Place the watch at or around the
    mark fij) (M) appearing at the
    center of the microphone in a
    manner that its case back may
    be turned up o r face you which-
    ever makes the higher sound
    level in the earphone. See Figs. 1
    and 2.
•   Battery change
    Remove the battery hatch from
    the bottom of the microphone
    by turning it counterclockwise             Photo 2
    with a coin or the like. Replace
    the two old cells with new ones,
    and close the battery hatch by
    turning it clockwise. Set two
    cells so that their negative faces
    may come on the far side in the
    battery holder. Use the battery
    U.C.C. 301 for SEIKO watch
    use. See Photo 4.
•   Cleaning
    To clean the microphone, wipe
    it gently with a soft, dry cloth.
                                               Photo 3   Photo 4
    Never use thinner, alcohol or any
    other solvent or chemical.
                                         -9-
WIRING AND OPERATION
• Put the connector plug of the power cord into the power cord connector
  (S) in the back of OT-99.
• Put off the power switch (G), and connect the power cord plug into an
  outlet . QT-99 employs an oven-controlled crystal oscillator for highly ac-
  curate and stabil ized measurement, and it takes some 20 min. for the oven
  to attain a stabilized temperature, that is, for the OT-99 to become ready
  for measurement at a required accuracy, after plugging the power cord to
  the outlet. Then, turn on the power switch (G), and the POWER indicator
  (A) will light up, showing the measurement is ready.
• For the measurement of ordinary watches, set the watch signal divider
  selector switch (P) at GENERAL.
• Put the plug of the Electro-magnetic/Electric-field detection microphone
  (L) into the INPUT jack (K).
• Set the GATE TIME/CHANN EL setting switch (I) in position.
  Fo r the measurement of a watch for which a channel is specified, set the
  switch (I) at that channel.
  For other watches, use the GATE TIME.
  For those watches whose frequency is less than 1 Hz, select a measuring
  t ime in an integral multiple of the generation period of watch signal.
  For stabilized measurement, it is recommended to select an even-numbered
  multiple.
   Ex.:
          Frequency (period)           Measurement at a gate time of
   For almost every watch whose frequency is 1 Hz or up, any gate time will
   be available for measurement.
   Note that the gate t ime available is limited for those watches whose fre-
   quency has a decimal fraction as shown below.
   Ex.:
          3601/3 Hz (360.3), 170 2/3 Hz (170.6 ). 5 112 Hz (5.5) (Refer to (P). )
                                         -10-
  Where a number of gate times are available, it is recommended to use the
  longer rather than the shorter gate time, because it is recognized that the
  longer the measuring time, the higher the measuring accuracy. There are
  some special types of watches which defy measurement at an odd-number-
  ed period. For such watches, use an even-numbered period. This is particu-
  larly the case with balance wheel type watches which may not be measured
  at an odd-numbered period under the influence of unbalanced swing.
• For those watches for which a channel is not specified, the watch selection
  switch (E) must be set.
  Select and depress one of the push buttons to meet the type of a given
  watch, and the selection of frequency will be carried out automatically.
  Green·button: For those leaping-hand watches, such as SEIKO analogue
                   type quartz watches, whose frequency ranges from 1/120
                   Hz to 12 Hz, select the green button.
   White button:    Use th is button for SE I KO Digital type quartz watches,
                    other liquid crystal watches or for electronic watches of
                    12 Hz to 64 Hz.
  Red button:       Use this bu tton for those quartz or tuning fork sweep-
                    hand watches of more t han 60 Hz or LED watches.
  Grey button:      Use t h is button for the measurement of ordinary balance
                    wheel ty pe watches (incl. battery ones) . If this button is
                    depressed, the decimal point will be shifted to allow the
                    daily rate measurement with in ± 199.9 sec./day. With the
                    grey button, it is possible to measure leap-hand quartz
                    watches of 1 Hz to 12 Hz. but the daily rate is shown in
                    0 .1 sec./day.
  It is not necessary to operate these buttons when the channel is used for
  measurement. If any of the buttons but the grey one is depressed, the
  measurement will not be affected. In the case of channel measurement,
  the computer will handle all the processes according to the programmed
  data concerning type of watch and measuring method. (If the grey button
  is selected, the channel measurement will be impossible as the measuring
  unit is 0.1 sec./day .)
• Set the earphone plug into the EARPHONE jack (F).
• Set the LEVEL adjuster (J) at AUTO (turn it counterclockwise until a
  click is heard.)
• Set the switch (N) on the electro-magnetic/electric-field microphone (L)
  to meet the type of the watch to be measured. ( For details, refer to
  "FUNCTION OF ELECTRO-MAGNETIC/ELECTRIC-FIELD DETEC-
  TION MICROPHONE DM-1" on page 8.)
                                   - 11-
• Put on the earphone and place the watch in the center (marked position)
  of the microphone platform, and shift the watch or change its position
  until the watch signal is heard largest.
  (For an LED watch, the measurement should be made with its display on.)
  * For the use of other microphones, refer to relevant manuals.
• Measurement is started automatically by placing the watch on the plat·
  form of the microphone. If the measurell)ent is started with the operator's
  finger on the watch or if the operator's finger touches the watch during
  measurement, the -signal level may be changed to cause an error in the
  measurement. (A vibration of the operator's finger is communicated to
  the watch to change the relative position between the watch and micro-
  phone, developing a change in the signal level. The error is not due to the
  change in the timing of the watch itself.)
  In such a case, disregard the affected measurement, and read the next
  daily rate measured. If the reset button (H) is depressed immediately after
  the watch has been set on the microphone, the correct reading will be
  obtained from the beginning. The measurement is continued repeatedly
  until the watch is removed from the microphone.
• Almost every watch can be measured with the LEVEL adjuster (J) at
  AUTO. If the INPUT indicator (C) blinks precariously, turn the knob (J)
  c lockwise.
    Note: The level adjustment has nothing to do with the volume of the earphone.
    For the measurement of balance wheel type watches with an acoustic
    microphone, turn the level adjuster from the AUTO position for better
    results. But be sure to keep the microphone away from acoustic noise and
    mechanical vibration. The INPUT indicator (C) turns on and off at the
    same frequency as that of the watch. If the watch has a high frequency,
    the indicator will seem as if it stayed lit. Whether the level adjustment is
    proper or not can be judged by the blinking state of this indicator.
•   Immediately after the start of measurement, the display will be in the
    blank, during which the first measurement is going on. If the GATE TIME/
    CHANNEL setting switch is changed over while the data is displayed, the
    measuring circuit will be reset to blank out the display and start the
    measurement anew. This is also true of the case where the watch selection
    switch (E) is changed over.
    After the daily rate is measured, the display is automatically reset to ex-
    tinguish when the watch is removed. The time to be required for the dis-
    play to extinguish varies depending upon the gate time set.
                                        - 12-
•  If the RESET indicator blinks at a fast rate, it indicates that something is
  wrong with the switch setting.
  Check the switch setting by following the procedures below.
   1. The button of the watch selection switch is not depressed when the
       gate time is set.
  2. Two adjoining buttons of the watch selection switch are depressed
       when the gate time is set.
  3. When the watch signal divider selector switch is set at other than
       GENERAL, its setting does not agree with the gate time selected.
       (Ex.: The gate time is selected at 4 sec., 8 sec. or 10 sec. with +N/3.
        (For sweep-hand watch only))
  4. When an unoccupied channel is selected. (No measuring routine is
       programmed.)
  5 . In the case of channel measurement, the grey button of the watch
       selection switch is depressed .
• In the following cases, measurement is impos.5ible and the display will not
  function.
  A. When no input signal is supplied.
       (INPUT indicator (C) will not light up.)
  B. When the button of the watch selection switch (E) is not depressed
       properly for gate time measurement.
  C. When the daily rate of a watch exceeds the measu ring range.
  D. When the Quartz Tester is affected by strong noise.
       Fo r example, in case that the electro-magnetic m icrophone is used and
       if the earphone makes a scratching sound or a hum without placing the
       watch on it, don't measure the daily rate.
          (In th is case. the INPUT indicator will blink even if no watch is set
          on the microphone. If the INPUT indicator goes out when the m icro-
          phone p lug is disconnected, you may consider that external noises
          are responsible for the trouble .)
• The measuring method varies depending upon the watch calibre. Some
  watch must be measured through the channel setting. When measuring any
  watch, be sure to refer to a releva nt Watch Technical Guide.
                                   -1 3-
QT-99 TABLE OF MEASURABLE RANGES
                                                                                                                       -----
                                                                                                     Microphone
Electro-fflagnetic Special SEI !(0 T\l!fin Quartz Cal. 99 .. Set at CH·1. Pull out the crown completely.
                                                                                                                       -----
                                                                                            i
                                                                                            L     Elec,;ric-field                             Special
                                        I            I
                                        Channel setting type ,         I                    -     Electro-magnetic     Green   STEP           1/120-12 H-z
                                                                                                                                                                :.t:111.U UMt:t,A _(,Megaquaru) BErn1US Bifora
                                                                                                                                                                mioH Neo ~ic FAVR.~~~UB.Aui:JYN~HANS                                    ,,
                                        quartz crystal watches                                                                                                        17"'N on ·1i:R ARC                  .p
                                                                   ~        Analogue             1:lectro-magnetic     White    LCD.          12 -64 Hz         CITIZEN (16 Hz)
                                        11
                                                     I
                                              Ouartz crystal   r                            ~
                                                                                                  Electro-magnetic     Red
                                                                                                                               LEO.
                                                                                                                               SWEEP
                                                                                                                                              60-1200Hz
                                                                                                                                                                CERTINA (Ultr'1Jartz) tONGll',jES (Ultraciuartz)
                                                                                                                                                                ~w.c.     fHP II ADO
                                                                                                                                                                  MEGA f8129
                                                                                            c
                                              watches
                                                                                                                               LED.           60 - 1200 Hz      SEEMOS (LED( OMEG/\ (LEDi IJRANUS (LEDi
                                                                                                  Electro,magnetic     Red                                      CITIZEN (LEDi RICOH (LED) ORIENT (LED)
                                                                                                                                                               --               ----------- - -                        --- - ~-- ---- --- -                        __
                                                                                                                                              -----
                                                                                                                               SWEEP
                                                                       Digital display by                                                                        - -----                                - --    -- -                                   - -- -           ,.
                                                                                            c
                                                                       LED system                 Ultrasonic                                                    SEIKO (05LC, 05LCA, 061..C, 06LCA, 0114, 0124. 0634, 0644, 0654, 0664)
                                                                                                  (32 KHz)             Green   STEP                             SE 11(0 Digital Stop Watch (The daily rate is measured by using electric-field detection microphone.)
                                                                   ~ Digital display by                                                   I                     CITIZEN ORIENT GRU!:N BWC TIMEX NEPRO
                                                                       LCD system                                               LCD.          12-64 Hz          Microma SANYO Quartz WALCHRON
                                                                                                  Electric-field       White                                    CASIOTRON 01 , 02, 03, 04 (For 04 Series. meas.iring time. is6 or 12 seconds.)
                        Watch   -                                                                                               LED.                            OMEGA f300 . LONGIN ES riaume & Mercier BULOVA
                                            -Tuning fork watches                                  Electro-maglletic    Red                    60-1200 Hz        tW.C. ETERNA. CITIZEN HI-SONIC)
                                                                                                                               SWEEP                            RADO CERT INA UNIVERSAL
Classification of                                             Electronic watches _                                                                              St: IKU .!1J7t;L, ..>..>c , :S/t:L)
measurable timepieces                                                                             Electro-magnetic     Grey     MECH.         1/1 20 - 12 Hz    CITIZEN (COSMOTRONI etc.
                                             Balance wheel - ((Battery)                                                                                         (The acoustic stand-typed microphone can also be used.I
                                             watches          Mechanical watches                                                                                King SEIKO
                                                                                                  Acoustic stand       Grey     MECH.         1/120- 12 Hz
                                                              (Mainspring)        -                                                                             Grand SEIKO, etc.
                                                                                                                                                                SEIKO (71005, 71007, 71101, 71507)            RADO (CHRONOMETER)
                                                                                                  Plate-typed or
                                                                                            -     clip-typed probe     Green   STEP           1/120- 12 Hz      SCHJIGAR JUNGHANS Aicron Quartz
                                                                                                                                                                JEC
                                            _ Quartz Crystal Clocks                               Plate-typed or                LCD.          12 - 64 Hz        SEIKO (71002)
                                                                                                  clip-typed probe     White                                    CITIZEN (Crystron)
                                              (Analogue, LCD, LEDi
                                                                                            ..__ Plate-typed or                LED.                                 SEIKO (71003, 71006, 71009, 71201, 71202, 71502, 71503, 71504, 71505)
                                                                                                                       Red                    60- 1200 Hz
                                                                                                  clip-typed probe             SWEEP                                JECO Rhythm Quartz (64 Hz)
                                                                                                  Plate-typed or                LED.                                SEIKO (64001, 64501, 66004, 66504)         CITIZEN (E litronl
                        Clock       -       '-Tuning fork clocks                                  clip-typed probe     Red      SWEEP         60-1200 Hz
                                                                                                                                                                    JECO
                                                                           Battery-operated _     Plate-typed probe             MECH.         1/120- 12 Hz          Various marks (The hanger-typed microphone can also be used.)
                                                                                                                       Grey
                                            '- Balance wheel   ~ clocks
                                               clocks
                                                                           Mechanical clocks -    Hanger typed         Grey     MECH .        1/120 - 12 Hz         Various marks
                                                                           (Main spring, etc.)
                                                                                                 Notes: 1. When the daily rate of the LED display watch is measured by using the elect ro-magnetic/electric-field detection microphone, be sure to display all digits by
                                                                                                           pushing down the button with adhesive tape before the watch is placed on the microphone.
                                                                                                        2. The coverage by the electro-magnetic/electric-field detection microphone furnished is shadowed.
                                                                                                                                       -1 4-
  WIRING DIAGRAM
                     L£0-
                LCD SWEEP StEI" Mt'.C'"'.,                                            Elecvo-Magnetic/
            ct:Jt=D                                                                   Electric •f ield detection
                                                  - ~                                 microphone OM,1:
                                                                                      Used fo1 t!tt."-IIVll•l
                                                                                      W:l(ChQS ol ana1oguc ,)nd
                                                  ~4
      o.._ rc
                    u,oO
                t tM£   LEVCL                                                         d1\)1li'll TV
                                                                                                     "'"
e;,.Akt~l l o ...
                                       --
                                     INP1Jl
                                                  -~
                                                                                       war<:h P,S only
                                                                                                                            ~
                                                       PlaHHypcd probe l0ptional)
                                                       Used for almost all type-. of
                                                       doc.l ope, ottn9         0<1   a bc-'lttefy
                                                                                                                            ~
                                                                                                                            Balance wheel
                                                                                                                            type Cl ock
                                                                                                                            1ma,nspril"'lt'J. e ll: I
                                                   - 15-
QT-99 SPECIFI CATIONS
 1. Measurable timepiece and Hertz: Watches and clocks w ith quartz crystal,
      tun ing fork and balance wheel ( 1/120 Hz - 1,200 Hz)
 2. Measuring time
     Gate time measurement: 4 sec., 6 sec., 8 sec., 10 sec., 12 sec., 30 sec.,
           60 sec., 120 sec.
     Channel measurement: Integral number second from 2 sec. to 120 sec.
           (depending upon the contents stored in the memory element)
 3. Observable measuring minimum value: 0.01 sec./day or 0.1 sec./day
           (Round off the franct ion to three or two dec ima l places.)
 4. Observable measuring range: - 19.99"' +19.99 sec./day or
                                       -199.9 - + 199.9 sec./day
 5. Measuring system:
     • Au tomatic start continuous measu ring system (The daily rate can be
        measured automatically by placing the watch on the microphone.)
     • Micro-computer system
 6 . Display system: + or - four digits numerical segment display system
     (The d igital display is extinguished in case of overflow or when signal is
     not su pplied.)
 7. Display time: Corresponding to the measuring t ime
 8. Crystal oscillator device: Type: Oven,controlled device
                                    Frequency: 4.32 MHz
                                    Accuracy: 10~8
 9. Power requirements:
     A C 100, 110,120,200,220,240 V (±10%; 50-60 Hz)
     Power consumption : 22 W
     Power consumption of oven-control device (When the power switch is
     turned off) : 3 "' 4 W
10. Operational temperature range and humidity : 0°C "' 50°C, Normal
     humidity
11. Dimensions and weight: 110mm (H ) X 325mm (W) X 328mm (D);
     7.2 kg.
12. Accessories:
     • Electro -magnet ic/E lectric-field detection microphone DM -1 (Used for
        analogue and dig ital electron ic watches) (includ ing 2 silver oxide
        batteries-U.C.C. 301) ..... . . .. . . .. .. . ... . . ...... ... 1
     • Earphone for signal monitoring (can also be used with Timegrapher
        IC-70) .. . . .. . . . . . . . ..... . . . . . . . . . . . . . . . . . . . . . . . 1
     • Power cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
     • Earth cable . . .. . ....... . .. .. .. . . ... . . ... . . . .... .
     • V inyl cover
                                           - 16-
13. Optional accessories
   • Stand-typed microphone K-410 (Used for balance wheel watches; can
     also be used with t he Timegrapher IC-70)
   • Hanger-typed microphone (Used for balance wheel mechanical clocks;
     can also be used with the T imegrapher IC-70)
   • Plate-typed probe K-401 and Clip-typed probe K-504 (Used for elec-
     tronic clocks, can also be used with Timegrapher IC-70)
   • Ultrasonic microphone US·32 (Used for digital watches with the
      crystal oscillator, 32 KHz)
                                -17-
TROUBLESHOOTING
                                      - 18-
• Voices are heard on the earphone.
  1. Are there any wireless stations near around which interfere with the
     measuring system?
      -   Contact the w ireless stations for measures against interference.
• Daily rate is not displayed or it goes out soon after it is displayed.
  1. Is the correct microphone used to meet the type of watch?
      -   Select the m icrophone according to the type of watch.
          (Refer to "QT-99 Table of Measurable Ranges" .)
  2. Is the correct button of the watch selection switch (E) depressed?
      -   Work the correct button. (Refer to "QT-99 Table of Measurable
          Ranges" .)
  3 . Is the daily rate of the watch beyond the measuring range?
  4. Is the watch placed in the right position on the microphone?
      -   Listen to the watch signal over the earphone, and place the ri ght
          position.
  5. Is the microphone strongly affected by nearby electrical noise sources?
      -  Tu rn off the electri cal app liances that make noises to interfere with
         the measuring system.
  6. Is the level adjustment proper?
     - Adjust the level as required.
  7. Is the ordinary method·applied when the channel measurement must be
     followed?
      -   Set the QT -99 for cha nnel measurement, and reset the watch as
          requ ired.
• Daily rate changes quickly over a wide range.
  1. Is the instantaneous daily rate of watch changing over a wide range?
  2. Is the microphone strongly affected by nearby electrical appliances?
      -   Turn off the noisy appl iances.
  3. Is the watch placed properly on the microphone?
      -   List en to the watch signal over the earphone, and place the r ight
          position.
  4. Is the level adjusted properly?
      -   Turn the LEVEL adjuster as requ ired.
   5. Is the ordinary method applied when the channel measurement must be
      followed?
      -   Set the QT-99 for channel measurement, and reset the wa tch as re-
          qu ired.
                                       - 19-
  Distributor:   K . Hattori & Co .• Ltd.
Manufacturer:    Fuji Electronic Industry Co., Ltd .
                    Tokyo, Japan
                                                       Printed in Japan