[ARKON]
Product Name Specifications
00. Product Description Battery powered electromagnetic flowmeter
01. Batteries Battery pack
02. Battery life* Up to 10 years (5-pack)
02.* Battery life dependent on power saving
02.* usage and transmission of data
03. Accuracy of reading 0,4%
04. Electrodes 4 electrodes. 2 built-in for earthing
05. Communication USB via MODBUS RTU
06. Isolated binary output Pulse
07. Ambient temperature -20°C to +60°C
08 .Electrical conductivity min. >= 5 uS/cm
09. Flow-direction Bi-directional
10. Graphic display and keypad 4 totalizers: total +, total -, total, aux +
MAGB2 - CD25HR40HA 11. Datalogger Included
12. Medium temp. compact 70°C
13. Medium temp. remote (PTFE) 130°C
14. MAGB2 manual Included
15. MAGB2 SW Included
16. Cable length Standard 6 m (FOR REMOTE VERSION)
17. IP Protection Sensor IP68, Transmitter IP68
18. Calibration Included
19. Packing Included
A. Version Compact (C)
B. Connection Type DIN (D)
C. Nominal Size 0025
D. Liner Hard Rubber (HR) - max temp. 70°C
E. Nominal Pressure PN40 (40)
F. Electrodes Hastelloy (HA)
00. Product Description Battery powered electromagnetic flowmeter
01. Batteries Battery pack
02. Battery life* Up to 10 years (5-pack)
02.* Battery life dependent on power saving
02.* usage and transmission of data
03. Accuracy of reading 0,4%
04. Electrodes 4 electrodes. 2 built-in for earthing
05. Communication USB via MODBUS RTU
06. Isolated binary output Pulse
07. Ambient temperature -20°C to +60°C
08 .Electrical conductivity min. >= 5 uS/cm
09. Flow-direction Bi-directional
10. Graphic display and keypad 4 totalizers: total +, total -, total, aux +
MAGB2 - CD80HR16HA 11. Datalogger Included
12. Medium temp. compact 70°C
13. Medium temp. remote (PTFE) 130°C
14. MAGB2 manual Included
15. MAGB2 SW Included
16. Cable length Standard 6 m (FOR REMOTE VERSION)
17. IP Protection Sensor IP68, Transmitter IP68
18. Calibration Included
19. Packing Included
A. Version Compact (C)
B. Connection Type DIN (D)
C. Nominal Size 0080
D. Liner Hard Rubber (HR) - max temp. 70°C
E. Nominal Pressure PN16 (16)
F. Electrodes Hastelloy (HA)
00. Product Description Battery powered electromagnetic flowmeter
01. Batteries Battery pack
02. Battery life* Up to 10 years (5-pack)
02.* Battery life dependent on power saving
02.* usage and transmission of data
03. Accuracy of reading 0,4%
04. Electrodes 4 electrodes. 2 built-in for earthing
05. Communication USB via MODBUS RTU
06. Isolated binary output Pulse
07. Ambient temperature -20°C to +60°C
08 .Electrical conductivity min. >= 5 uS/cm
09. Flow-direction Bi-directional
10. Graphic display and keypad 4 totalizers: total +, total -, total, aux +
MAGB2 - CD100HR16HA 11. Datalogger Included
12. Medium temp. compact 70°C
13. Medium temp. remote (PTFE) 130°C
14. MAGB2 manual Included
15. MAGB2 SW Included
16. Cable length Standard 6 m (FOR REMOTE VERSION)
17. IP Protection Sensor IP68, Transmitter IP68
18. Calibration Included
19. Packing Included
A. Version Compact (C)
B. Connection Type DIN (D)
C. Nominal Size 0100
D. Liner Hard Rubber (HR) - max temp. 70°C
E. Nominal Pressure PN16 (16)
F. Electrodes Hastelloy (HA)
MAGB1 - 5x3,6 V battery pack
Cable Not included
MAGB2 RS485 module - RS485I Communication Via MODBUS RTU
Version Isolated (RS485I)