Commercial Air Conditioners 202
M-Thermal Mono/Split A Series
DC Inverter 65°C -25°C
R32 environmental refrigerant Structure innovation
Single fan compact structure design for big capacity with
lower noise
Higher heat transfer coefficient and better performance
270mm thinnest size in industry for indoor unit, which is ideal
Less charged volume is needed in the system
transformation plan for gas burner and convenient for replacing
Less costs and easier to get R32
Lower GWP and carbon emission (GWP: Global Warming Potential)
2088
2500
2000
1500 675
1000 270mm
Single fan structure Thinnest!
500 Greatly reduces noise!
0
GWP Extremely silent
R32 R410A Two level of silent mode provides more comfort
Silent mode minimum sound power level 53dB
Inverter system design
All the units are equipped with DC compressor, DC fan motor, DC
pump, which allows precise control of motor speed, ensuring that only
the power necessary to perfectly match the real load is used and energy
saving.
Multi-function wired controller
and APP control
Multiple languages meet customer needs
Modbus protocol and network flexibility
Maximum 6 units controlled by one controller and automatic
addressing;available on 31 May, 2020
Holiday away & Holiday home makes life convenient
Built-in wifi module supports APP control
Powerful heating with high efficiency
No capacity attenuation at -10°C ambient temperature
Operation range down to -25°C
Maximum LWT reach 65°C Through APP, user can
Single point maximum COP 5.20 Check the running state of heat pump, zone switch, operation
SCOP 5.21, Energy efficiency level: A+++ mode and temperature.
Set switch, operation mode and temperature of each zone
Know energy consumption and energy-saving suggestion
35
7 8
8 9
9 9
kW kW
2019
65°C -25°C
2
Smart Grid function USB function
Heat pump adjusts the operation according to different electrical signals. Realize setting transmission between wired controllers
Power consumption of the system can be automatically adjusted according Realize program upgrade with one key and save the time of
to the peak and valley power to reduce the power consumption to the on-site installation
greatest extent
DHW pump function
The DHW pump function is used to return water in the water pipe net to
the hot water tank according to set timer. With the function, when hot
water is needed, hot water will flow out from tap immediately without
waiting time.
Climate curve function
Hot water Cold water
Totally there are 32 climate correlation curves for choice and one custom
curve is optional. Once the curve is selected, the unit set the outlet water
temperature automatically according to the outdoor ambient temperature,
which realizes intelligent control.
Disinfect function
The disinfect function is used to kill legionella by 60-70 °C water
to ensure the health and safety.
70 Legionella die immediately
60 90% legionella die in 2 minutes
50 90% legionella die in 2 hours
40
30 Legionella is active
Zones control more flexibility 20
10 Legionella survive but is inactive
0
More accurate low temperature area temperature control
DC water pump accurate control of water flow and
electromagnetic three-way valve cycle regulation to achieve stable
low temperature heating
Thermostat 2
T Radiator
Zone2 Zone 2 is controlled by thermostat 2
3-way valve
M
M
3-way valve
Zone1 Zone 1 is controlled by thermostat 1
T
Thermostat 1 Floor heating
Hydronic adapter board is optional. With the help of hydronic box adapter board, maximum 8 thermostats for 8 rooms
are available to control heat pump, which greatly improves the operation convenience.
3
Mode combination Mono 8~16kW
There are 4 single operation mode (Cool, Heat, DHW, Auto) and 3
combined operation mode to meet different demands of using.
945
25
526
Auto & DHW mode
1385
Split outdoor unit 4~6kW
25
712
Cool & DHW mode Heat & DHW mode
Fast DHW function
FAST DHW function is used to force the system to operate in DHW
mode when hot water is needed urgently.
426
Heat pump 1008
Split outdoor unit 8~16kW
AHS Water tank
865
TBH
Additional control
Remote control for ON/OFF, TBH, AHS
523
Balance tank temperature sensor (field supplied) ensures accurate
water temperature control 1118
Unit Dimensions (Unit: mm) Split indoor unit
Mono 4~6kW
270
420
792
1295
790
429
4
Specifications
Mono
V4W/ V6W/ V8W/ V10W/ V12W/ V14W/ V16W/ V12W/ V14W/ V16W/
Outdoor uni t model MHC- D2RN8-B
D2N8-B D2N8-B D2N8-B D2N8-B D2N8-B D2N8-B D2N8-B D2RN8-B D2RN8-B
Power supply V/Ph/Hz 220-240/1/50 380-415/3/50
Ca pa ci ty kW 4.20 6.35 8.40 10.0 12.1 14.5 15.9 12.1 14.5 15.9
Hea ti ng1 Ra ted i nput kW 0.82 1.28 1.63 2.02 2.44 3.15 3.53 2.44 3.15 3.53
COP 5.10 4.95 5.15 4.95 4.95 4.60 4.50 4.95 4.60 4.50
Ca pa ci ty kW 4.30 6.30 8.10 10.0 12.3 14.1 16.0 12.3 14.1 16.0
Hea ti ng 2 Ra ted i nput kW 1.13 1.70 2.10 2.67 3.32 3.92 4.57 3.32 3.92 4.57
COP 3.80 3.70 3.85 3.75 3.70 3.60 3.50 3.70 3.60 3.50
Ca pa ci ty kW 4.40 6.00 7.50 9.50 11.9 13.8 16.0 11.9 13.8 16.0
Hea ti ng3 Ra ted i nput kW 1.49 2.03 2.36 3.06 3.90 4.68 5.61 3.90 4.68 5.61
COP 2.95 2.95 3.18 3.10 3.05 2.95 2.85 3.05 2.95 2.85
Ca pa ci ty kW 4.50 6.50 8.30 9.90 12.00 13.50 14.90 12.00 13.50 14.90
Cool i ng4 Ra ted i nput kW 0.82 1.35 1.64 2.18 3.04 3.75 4.38 3.04 3.75 4.38
EER 5.50 4.80 5.05 4.55 3.95 3.60 3.40 3.95 3.60 3.40
Ca pa ci ty kW 4.70 7.00 7.45 8.20 11.5 12.4 14.0 11.5 12.4 14.0
Cool i ng 5 Ra ted i nput kW 1.36 2.33 2.22 2.52 4.18 4.96 5.60 4.18 4.96 5.60
EER 3.45 3.00 3.35 3.25 2.75 2.50 2.50 2.75 2.50 2.50
Seasonal space
Water outlet at 35oC class A+++
heating energy
efficiency class6 Water outlet at 55oC class A++
Type(GWP) R32(675)
Refrigerant
Charged volume kg 1.40 1.40 1.75
Sound power Level7 dB 55 58 59 60 65 65 68 65 65 68
Unit dimension (W×H×D) mm 1295×792×429 1385x945x526
Packing dimension (W×H×D) mm 1375x965x475 1465x1120x560
Net/Gross weight kg 98/121 121/148 144/170 160/188
Cooling °C -5̚43
Outdoor air
temperature range Heating °C -25̚35
DHW °C -25̚43
Water side heat exchanger Plate type
Water pump Max. pump head m 9
Water side connection mm R1" R5/4"
Standard mounted kW /
Optional kW 3 3 3/9 3/9 3/9 3/9 3/9 3/9 3/9 3/9
Backup E-heater 8
Capacity steps 1 1 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3
3kW 220-240/1/50
Power supply V/Ph/Hz
9 kW 380-415/3/50
Cooling °C 5̚25
Water outlet
temperature range Heating °C 25̚65
DHW˄tank˅ °C 30̚60
Notes:
1. Evaporator air in 7°C, 85% R.H., Condenser water in/out 30/35°C
2. Evaporator air in 7°C, 85% R.H., Condenser water in/out 40/45°C
3. Evaporator air in 7°C, 85% R.H., Condenser water in/out 47/55°C
4. Condenser air in 35°C. Evaporator water in/out 23/18°C
5. Condenser air in 35°C. Evaporator water in/out 12/7°C
6. Seasonal space heating energy efficiency class testes in average climate general conditions.
7. Testing standard: EN12102-1.
8. Backup electric heater is built into all models.For three phase type backup electric heater, 3/6kW can be achieved by changing DIP switch when heat pump is equipped with 9kW.
9. Relevant EU standards and legislation: EN14511; EN14825; EN50564; EN12102; (EU) No 811/2013; (EU) No 813/2013; OJ 2014/C 207/02:2014.
5
Split
Outdoor unit model name MHA- V4W/D2N8-B V6W/D2N8-B V8W/D2N8-B V10W/D2N8-B V12W/D2N8-B V14W/D2N8-B V16W/D2N8-B V12W/D2RN8-B V14W/D2RN8-B V16W/D2RN8-B
Indoor unit model name HB-A60/CGN8-B HB-A100/CGN8-B HB-A160/CGN8-B
Capacity kW 4.25 6.20 8.30 10.0 12.1 14.5 16.0 12.1 14.5 16.0
Heating1 Rated input kW 0.82 1.24 1.60 2.00 2.44 3.09 3.56 2.44 3.09 3.56
COP 5.20 5.00 5.20 5.00 4.95 4.70 4.50 4.95 4.70 4.50
Capacity W 4.35 6.35 8.20 10.0 12.3 14.2 16.0 12.3 14.2 16.0
Heating2 Rated input W 1.14 1.69 2.08 2.63 3.24 3.89 4.44 3.24 3.89 4.44
COP 3.80 3.75 3.95 3.80 3.80 3.65 3.60 3.80 3.65 3.60
Capacity W 4.40 6.00 7.50 9.50 12.0 13.8 16.0 12.0 13.8 16.0
Heating3 Rated input W 1.49 2.00 2.36 3.06 3.87 4.60 5.52 3.87 4.60 5.52
COP 2.95 3.00 3.18 3.10 3.10 3.00 2.90 3.10 3.00 2.90
Capacity W 4.50 6.55 8.40 10.00 12.00 13.50 14.90 12.00 13.50 14.90
Cooling4 Rated input W 0.81 1.34 1.66 2.08 3.00 3.75 4.38 3.00 3.75 4.38
EER 5.55 4.90 5.05 4.80 4.00 3.60 3.40 4.00 3.60 3.40
Capacity W 4.70 7.00 7.40 8.20 11.6 12.7 14.0 11.6 12.7 14.0
Cooling5 Rated input W 1.36 2.33 2.19 2.48 4.22 4.98 5.71 4.22 4.98 5.71
EER 3.45 3.00 3.38 3.30 2.75 2.55 2.45 2.75 2.55 2.45
Seasonal space Water outlet at 35⁰C class A+++
heating energy
efficiency class6 Water outlet at 55⁰C class A++
OUTDOOR UNIT
Power supply V/Ph/Hz 220-240/1/50 380-415/3/50
Type(GWP) R32(675)
Refrigerant
Charged volume kg 1.50 1.65 1.84
Sound power Level8 dB(A) 56 58 59 60 64 65 68 64 65 68
Unit dimension (W×H×D) mm 1008×712×426 1118×865×523
Packing dimension (W×H×D) mm 1065×800×485 1180×890×560
Net/Gross weight kg 58/64 77/88 96/110 112/125
Cooling ⁰C -5~43
Outdoor air
temperature range Heating ⁰C -25~35
DHW ⁰C -25~43
INDOOR UNIT
Unit dimension (W×H×D) mm 420×790×270
Packing dimension (W×H×D) mm 525×1050×360
Net/Gross weight kg 37/43 39/45
Water pump Max. pump head m 9
Standard mounted kW /
Optional kW 3/9
Backup E-heater9 Capacity steps 1/3
3kW 220-240/1/50
Power supply V/Ph/Hz
9kW 380-415/3/50
Cooling ⁰C 5~25
Water outlet
temperature range Heating ⁰C 25~65
DHW˄tank˅ ⁰C 30~60
Sound power level8 dB(A) 38 38 42 42 43 43 43 43 43 43
Notes:
1. Evaporator air in 7°C, 85% R.H., Condenser water in/out 30/35°C
Ovlašeni uvoznik i distributer:
2. Evaporator air in 7°C, 85% R.H., Condenser water in/out 40/45°C
3. Evaporator air in 7°C, 85% R.H., Condenser water in/out 47/55°C
4. Condenser air in 35°C. Evaporator water in/out 23/18°C
5. Condenser air in 35°C. Evaporator water in/out 12/7°C
6. Seasonal space heating energy eciency class testes in average climate general conditions.
7. Relevant EU standards and legislation: EN14511; EN14825; EN50564; EN12102; (EU) No 811/2013; (EU) No 813/2013; OJ 2014/C 207/02:2014
8. Testing standard: EN12102-1
9. For three phase type backup electric heater, 3/6kW can be achieved by changing DIP switch when hydronic box is equipped with 9kW. Jovana Mikia 56, Subotica
T: 024/621-000
Commercial Air Conditioner Division
E: office@cimgas.rs
Midea Group W: www.cimgas.rs
Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde, Foshan, Guangdong, China
Postal code: 528311
cac.midea.com www.midea-group.com
Note: Product specifications change from time to time as product improvements and developments are released and may vary from those in this document.
GD MIDEA Heating & Ventilating Equipment Co. Ltd participates in the ECP programme for LCP-HP. Check ongoing validity of certificate:www.eurovent-certification.com