02-Jun-17
Addis Ababa Institute of Technology
School of Civil and Environmental Engineering
INTRODUCTION TO ES EN 1992:2015
By Dr.-Ing. Girma Zerayohannes
ES EN 1992-1-1:2005 Twelve sections:
Section 1: General
Section 2: Basis of design
Section 3: Materials
Section 4: Durability and cover to reinforcement
Section 5: Structural analysis
Section 6: Ultimate limit states
Section 7: Serviceability limit states
Section 8: Detailing of reinforcement and prestressing tendons General
Section 9: Detailing of members and particular rules
Section 10: Additional rules for precast concrete elements and structures
Section 11: Lightweight aggregate concrete structures
Section 12: Plain and lightly reinforced concrete structures
2
2
1
02-Jun-17
Section 1: General Information
Scope of code
Principles and application rules
Symbols
ES EN
1992:2015
EBCS 1995
E Effect of action
MEd Design value of the applied internal bending moment
3
3
Section 2: Basis of Design
Refers to ES EN 1990/ES EN 1991 for design life, limit state principles,
actions, etc.
Partial factors for materials for ULS
Design Situations for for for
concre reinforcing prestressing steel
te steel
Persistent & Transient 1.5 1.15 1.15
Accidental 1.2 1.0 1.0
4
4
2
02-Jun-17
Section 3: Materials - Concrete
New in ES EN 1992:2015 is the inclusion of HSC
C55/67, C60/75, C70/85, C80/95, C90/105 and the associated - relations
and differentiation of - relations for non-linear structural analysis and design
of cross-section
One project is using HSC
5
5
Section 3: Materials - Concrete
6
6
3
02-Jun-17
Section 3: Materials - Concrete
Stress-strain relations for the design of cross-sections
7
7
Section 3: Materials - Concrete
Stress-strain relations for non-linear structural analysis
8
8
4
02-Jun-17
Section 3: Materials - Concrete
Design compressive and tensile strengths
∝
=
∝ , .
=
Stress – strain relations for the design of cross-sections
9
9
Section 3: Materials - Concrete
• Simplified stress-strain relation- Bi-Linear
• Less accurate – for practical calculation loss of accuracy is very small
10
10
5
02-Jun-17
Section 3: Materials - Concrete
Simplified stress-strain-Rectangular
11
11
Section 3: Materials - Concrete
Confined concrete higher strength and higher critical strains (NEW)
fck,c = fck(1.0 + 5.02/fck)
c2,c = c2(fck,c/fck)2
cu2,c = cu2 + 0.22/fck (useful in the design of boundary elements
for EQ resistance)
12
12
6
02-Jun-17
Section 3: Materials - Reinforcing Steel
Stress-strain diagram of typical reinforcing steel
•Yield strength fyk (or the 0.2% proof stress, f0.2k) and tensile strength ftk
13
13
Section 3: Materials - Reinforcing Steel
For design either an inclined top branch with a strain limit and maximum
stress or a horizontal top branch without the need to check for the strain
limit (NEW)
14
14
7
02-Jun-17
Section 4: Durability and Cover to Reinforcement
Environmental conditions
15
15
Section 4: Durability and Cover to Reinforcement
Cover to Reinforcement
= +∆
= ,; ,
Cover for Bond, , : Depends on the diameter of bar
Cover for Durability, , : Depends on the exposure class and structure
class
∆ is normally taken as 10 mm
16
16
8
02-Jun-17
Section 5: Structural Analysis
New design methods (strut and tie method) and application rules (global
second order effects in buildings) are included in section 5
It is a very simple formula that allows the calculation of the lateral stiffness of
vertical bracing elements to limit the 2nd order moments to less than 10%
17
17
Section 5: Structural Analysis
Why limit the 2nd order moment?
Instability (critical ULS) is caused because the LFRS is unable to control
(limit) the 2nd order effects leading to instability.
Therefore limiting the 2nd order moments to less than 10% is a strategy to
preempt stability failure
Formula is similar to provisions for adequate lateral rigidity according to DIN.
Economy?
Good practices in the USA, recommend non-sway structures “which are
more economical than their sway counterparts” (Wight and MacGregor)
18
18
9
02-Jun-17
Section 5: Structural Analysis
Second order effects with axial load
Methods of analysis
a) Second order analysis based on nominal stiffness
b) Method based on estimation of curvature
19
19
Section 5: Structural Analysis
20
20
10
02-Jun-17
Section 5: Structural Analysis
Effective width of Flanges
The effective flange width of T and L beams is determined from:
21
21
Section 5: Structural Analysis
Effective Span of Beams and Slabs
The effective span l of beam or slab is:
= + + values of a1 and a2 may be determined from the figure
22
22
11
02-Jun-17
Section 6: Ultimate Limit States
Bending with or without axial force
Plane sections remain plane after bending so that:
a) The strains are linearly proportional to the distance to the
neutral axis and
b) The strain in the concrete is equal to he strain in the
reinforcement at the same depth in the section
The tensile strength of the concrete is ignored and no contribution is
taken for he concrete below the neutral axis in tension
23
23
Section 6: Ultimate Limit States
Partial view of design aid prepared using the strain distribution at ULS
24
24
12
02-Jun-17
Section 6: Ultimate Limit States
Partial view of design aid prepared using the strain distribution at ULS
25
25
Section 6: Ultimate Limit States
Shear
The strut inclination method is used for shear capacity checks
The shear is resisted by concrete struts in compression and shear
reinforcement acting intension
Shear formulae expressed in terms of force rather that stress
Designer free to choose a strut angle 22 ≤ ≤ 45
Notation
o , is the design shear resistance of the member without
shear reinforcement.
o , is the design value of the shear force which can be
sustained by the yielding shear reinforcement.
o , is the design value of the maximum shear force which
can be sustained by the member, limited by crushing of the
compression struts.
26
26
13
02-Jun-17
Section 6: Ultimate Limit States
Shear
Members not requiring design shear reinforcement
27
27
Section 6: Ultimate Limit States
Shear
Members requiring design shear reinforcement
For members with vertical shear reinforcement, the shear resistance is the
smaller value of:
28
28
14
02-Jun-17
Section 6: Ultimate Limit States
29
29
Section 6: Ultimate Limit States
New in the design for shear is also the need to take it further to satisfy
capacity design rules. Capacity design of members in shear
It is about complying with the design assumption for DCM and DCH that
frame structures dissipate energy during an EQ through the formation plastic
hinges primarily at the ends of the beams
So unlike the traditional way, shear designs follow only after flexural designs
with associated detailing is completed because the magnitude of the design
shear force is also a function of the design moment resistances of the beam
end sections.
30
30
15
02-Jun-17
Section 6: Ultimate Limit States
31
31
Section 6: Ultimate Limit States
Instability
In non-sway structures,
individual weak columns
could reach the ULS of
instability individually
Individual weak column
has reached the ULS of
instability
32
32
16
02-Jun-17
Section 6: Ultimate Limit States
• In sway buildings on the other hand a weak story, some stories or all stories
will reach the ULS of Instability at the same time. This kind of ULS if allowed,
is catastrophic.
• ES EN Standards have provisions that ensure compliance of buildings with
safety requirements regarding stability.
• The essential requirement to ensure stability is the right choice of the
structural systems. They are also called lateral force resisting systems
(LFRS).
• Failure to comply with the code provisions regarding stability in sway
structures have resulted catastrophic failures (see photos).
33
33
Section 6: Ultimate Limit States
Slender sway structure
with inadequate choice of
structural system
34
34
17
02-Jun-17
Section 6: Ultimate Limit States
Catastrophic instability
failure
35
35
Section 7: Serviceability Limit States
Considered serviceability limit states are
Stress limitation
Crack control
Deflection control
Crack control
Without direct calculation : by limiting the maximum bar diameter or
spacing between bars
With direct calculation and limiting the crack width below the given
allowable values
36
36
18
02-Jun-17
Section 7: Serviceability Limit States
Deflection control
Without direct calculation : by limiting the span to depth ratio
With direct calculation and limiting the deflection below ⁄250 or ⁄500
37
37
Section 8: Detailing of Reinforcement
Spacing of bars
Anchorage of longitudinal reinforcement
Laps and mechanical couplers
38
38
19
02-Jun-17
Section 9: Detailing of Members and Particular Rules
Beams
Solid slabs
Flat slabs Rules of minimum and maximum area of
Columns reinforcement, minimum and maximum
spacing between rebars, and additional
Walls
detailing rules for members are listed in this
Deep Beams section
Foundations In addition the much more involved
Columns additional detailing requirements for EQ
resistance must be observed
39
39
Section 10 -12
Section 10: Additional rules for precast concrete elements and structures
Section 11: Lightweight aggregate concrete structures
Section 12: Plain and lightly reinforced concrete structures
40
40
20
02-Jun-17
Thank you!
41
21