0% found this document useful (0 votes)
760 views90 pages

Databook NX g06

This document provides technical specifications for the NX-G06 0202P - 0812P chiller unit, including: - Product details such as refrigerant type, compressor type, heat exchanger type, and efficiency class. - Operating characteristics like wide operating temperature range and integrated hydronic module option. - Configuration codes explaining the unit size, number of compressors, and available versions. - Standard components of the unit like compressors, fans, heat exchangers, and expansion valves. - Certifications and compliances for quality, environmental, and safety standards. - Technical data sections covering performance, dimensions, electrical characteristics, and more. In 3 sentences or

Uploaded by

David Tieppo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
760 views90 pages

Databook NX g06

This document provides technical specifications for the NX-G06 0202P - 0812P chiller unit, including: - Product details such as refrigerant type, compressor type, heat exchanger type, and efficiency class. - Operating characteristics like wide operating temperature range and integrated hydronic module option. - Configuration codes explaining the unit size, number of compressors, and available versions. - Standard components of the unit like compressors, fans, heat exchangers, and expansion valves. - Certifications and compliances for quality, environmental, and safety standards. - Technical data sections covering performance, dimensions, electrical characteristics, and more. In 3 sentences or

Uploaded by

David Tieppo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 90

Data Book

NX-G06 0202P - 0812P_201904_EN R454B


ELCA_Engine ver.4.2.2.0

NX-G06 0202P - 0812P


49,6-218 kW
Chiller, air source for outdoor installation

(The photo of the unit is indicative and may vary depending on the model)

LOW GWP REFRIGERANT


CLASS A EFFICIENCY
ALUMINIUM MICRO-CHANNEL HEAT EXCHANGERS
ELECTRONIC EXPANSION VALVE
WIDE OPERATING RANGE
INTEGRATED HYDRONIC GROUP
CERTIFICATIONS

Product certifications

Voluntary product certifications

Check ongoing validity of certificate:


www.eurovent-certification.com
or
www.certiflash.com

System certifications

Quality System complying with the requirements of UNI EN ISO 9001:2008 regulation
Environmental Management System complying with the requirements of UNI EN ISO 14001:2004 regulation
Occupational Health and Safety Management System complying with the requirements of BS OHSAS 18001:2007
INDEX NX-G06 0202P - 0812P

1.1 PRODUCT PRESENTATION pg.1.1.1 / 1.1.3


2.1 INCIPIT pg.2.1.1 / 2.1.1
3.1 UNIT STANDARD COMPOSITION pg.3.1.1 / 3.1.4
4.1 OPTIONS pg.4.1.1 / 4.1.8
5.1 GENERAL TECHNICAL DATA pg.5.1.1 / 5.1.11
6.1 TECHNICAL DATA SEASONAL pg.6.1.1 / 6.1.0
EFFICIENCY IN COOLING (EN14825
VALUE)
7.1 OPERATING LIMITS pg.7.1.1 / 7.1.5
8.1 HYDRAULIC DATA pg.8.1.1 / 8.1.3
9.1 ELECTRICAL DATA pg.9.1.1 / 9.1.6
10.1 FULL LOAD SOUND LEVEL pg.10.1.1 / 10.1.6
11.1 DIMENSIONAL DRAWINGS pg.11.1.1 / 11.1.7
12.1 HYDRONIC GROUP pg.12.1.1 /
12.1.31

Liability disclaimer
The present publication is drawn up by of information only and does not constitute an offer binding upon Mitsubishi Electric Hydronics & IT
Cooling Systems S.p.A.
Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A. has compiled the content of this publication to the best of its knowledge. The data
contained herein are subject to change without notice. Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A. explicitly rejects any liability for
any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is
copyrighted by Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A.

The units highlighted in this publication contain R454B [GWP100 466] fluorinated greenhouse gases.

ELCA_Engine ver.4.2.2.0 NX-G06 0202P - 0812P_201904_EN R454B


LEGEND NX-G06 0202P - 0812P

Functions
Cooling

Refrigerant
R454B

Compressors
Scroll compressor

Fan
Axial fan

Exchangers
Plates heat exchanger

Other features right position


Energy Class A

Other features

Eurovent

ELCA_Engine ver.4.2.2.0 NX-G06 0202P - 0812P_201904_EN R454B


1.1 PRODUCT PRESENTATION

GREEN CERTIFICATION RELEVANT

Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., as a major


player in the world HVAC market and a leading manufacturer of energy
efficient, sustainable HVAC solutions, recognizes and supports the
diffusion of green certification systems, as an effective way to deliver
high performance buildings and improve the quality and the sustainability
of the built environment.

Since the first certification system was introduced at the beginning of


the 1990s, the demand for certified buildings has grown considerably,
as well as the number of standards, rating and certification programs.
Operating worldwide Mitsubishi Electric Hydronics & IT Cooling
Systems S.p.A., has extensive experience with many of them and is
active member of Green Building Council Italy.

Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., commitment


to develop responsible and sustainable HVAC solutions, is reflected by
a full range of premium efficiency products and systems, designed with
special care to improve building energy performance ratings, according
to major certification protocols, including LEED, BREAM, GREENSTAR,
BCA, NABERS, DNGB, HQE and BEAM.

To find out more about how our products contribute to enhanced green
certification rating and energy performance of a building, please refer
to:
https://www.melcohit.com/GLOBAL/Company/Green-Certifications/
QR%20code/

ELCA_Engine ver.4.2.2.0 1.1.1 NX-G06 0202P - 0812P_201904_EN R454B


PRODUCT PRESENTATION

Outdoor unit for the production of chilled water with hermetic rotary Scroll
compressors, low-GWP and ozone-friendly refrigerant R454B, axial-flow
fans, plate heat exchanger, micro-channel full-aluminum air coils and
thermostatic or electronic expansion valve, according to the model. The
range is composed by units equipped with two compressors in a
single-circuit configuration.

1.3 LOW GWP REFRIGERANT


The new generation refrigerant R454B is the most eco-sustainable
alternative to traditional refrigerant R410A, offering a 76% reduction in
terms of GWP (Global Warming Potential GWP of R454B = 466, GWP of
R410A = 1924 as per IPCC rev. 5th) and zero impact on the ozone layer.

1.4 CLASS A EFFICIENCY


The full range is available with the Class A efficiency rating. Thanks to the
generous sizing of the heat exchangers and an accurate control of the fan
speed, the CA versions grant a premium level efficiency in every noise
configuration.

1.5 ALUMINIUM MICRO-CHANNEL HEAT EXCHANGERS


The full aluminium micro-channel condenser coils deliver high efficiency
whilst ensuring a reduced refrigerant volume and a lower unit weight. The
e-coating protection (optional) grants the highest level of resistance to
corrosion in any condition, even in the most aggressive environments.

1.6 ELECTRONIC EXPANSION VALVE


The use of the electronic expansion valve generates considerable
benefits, especially in cases of variable demand and different external
conditions. It has been introduced into these units as a result of accurate
design choices concerning the cooling circuit and the optimisation of
operation in various different working conditions. The electronic
expansion valve comes standard in the high-efficieny CA version.

1.7 WIDE OPERATING RANGE


Full load operation is ensured with outdoor air temperature up to 46°C,
partial load operation is possible up to or even beyond 50°C. The unit can
produce chilled water at negative temperature (down to -10°C of leaving
water temperature). Dedicated accessories allow the unit operation down
to -20°C of outdoor air temperature.

1.8 INTEGRATED HYDRONIC GROUP


The optional built-in hydronic module already contains the main water
circuit components; it is available with single or twin in-line, for achieving
both low or high head.

ELCA_Engine ver.4.2.2.0 1.1.3 NX-G06 0202P - 0812P_201904_EN R454B


2.1 INCIPIT

NX-G06 / D / SL-CA / 0812P

Size
First 3 digits
Compressors size
Last digit
Number of compressors
P Plates heat exchanger

Versions
K
Key efficiency, compact version
LN-K
Low Noise, Key efficiency and compact version
SL-K
Super Low noise, Key efficiency and compact
version
CA
Class A of efficiency
LN-CA
Low Noise, Class A of efficiency
SL-CA
Super Low noise version, Class A of efficiency

Configurations
-
Basic function
D
Partial condensing heat recovery function

Product
NX-G06
Chiller, air source for outdoor installation
Refrigerant gas R454B

ELCA_Engine ver.4.2.2.0 2.1.1 NX-G06 0202P - 0812P_201904_EN R454B


3.1 UNIT STANDARD COMPOSITION

3.2 Chiller, air source for outdoor installation - general door lock isolator
Outdoor unit for the production of chilled water with hermetic rotary Scroll - control circuit transformer
compressors, low-GWP and ozone-friendly refrigerant R454B, axial-flow - IP44 protection
fans, plate heat exchanger, micro-channel full-aluminum air coils and - power circuit with electric bus bar distribution system (sizes 702, 712,
thermostatic or electronic expansion valve, according to the model. The 802, 812)
range is composed by units equipped with two compressors in a - numbered cables
- electric circuit breakers for compressors and fans
single-circuit configuration.
- remote ON/OFF terminals
- terminals for cumulative alarm block
3.3 Structure - relays for remote pump(s) activation for both circuits (only for units
Structure specifically designed for outdoor installation. Basement and
without hydronic pumps)
frame in hot-galvanised shaped sheet steel with a suitable thickness. All - antifreeze electric heater for heat exchanger
parts polyester-powder painted to assure total weather resistance. - electronic controller
- Compressors fastened to unit's frame with ani-vibration mountings. - multi-language user keypad with LCD display
- Compressor compartment separated from ventilation section. - Power supply 400V/3ph/50Hz+N+PE for units:
- Compressor compartment with soundproofing anclosure (thickness of - versions K, sizes 0152P..0352P
30 mm on sides and on top, 15 mm on bottom) (versions LN-K, SL-K, versions LN-K, sizes 0152P..0302P
LN-CA, SL-CA). versions SL-K e LN-CA, sizes 0152P..0202P
versions CA, sizes 0152P..0262P
3.4 Compressor - Power supply 400V/3ph/50Hz+PE for units:
Hermetic scroll compressors in tandem layout complete with oil sump - versions K sizes 0402P..0812P
heater, electronic overheating protection with centralised manual reset versions LN-K sizes 0352P..0812P
and a two-pole electric motor. versions SL-K e LN-CA sizes 0252P..0812P
versions SL-CA
3.5 Plant side heat exchanger
Braze welded AISI 316 plate heat exchanger. The heat exchanger is lined 3.10 Certification and applicable directives
on the outside with 9 mm thick closed-cell neoprene lagging to prevent The unit complies with the following directives and relative amendments:
condensation, with a thermal conductivity of 0,33 W/mK at 0°C. The heat - EUROVENT Certification program
exchanger is fitted with a differential pressure switch to monitor the - CE Declaration of conformity certificate for the European Union
correct flow of water when the unit is operating, thus preventing ice form - Machine directive 2006/42/EC
forming inside; if no flow is detected, the frost protection function is - ElectroMagnetic compatibility directive 89/336/EEC + 2004/108/EC
activated using a special heater. - Low Voltage directive 2006/95/EC
The heat exchanger comes standard with safety pressure release valve - PED Directive 2014/68/EC
- ISO 9001 Company´s Quality Management System certification
(water side) (10 bar). - ISO 14001 Company´s Environmental Management System
3.6 Source side heat exchanger certification
Full-aluminum microchannel coil.
- Longitudinal V-shaped coil module: Coil structure made with an 3.11 Tests
Tests performed throughout the production process, as indicated in
open-angle Longitudinal V-shaped layout.
- Horizontal V-shaped coil module: Coil structure made with an ISO9001.
open-angle Horizontal V-shaped layout. Performance or noise tests can be performed by highly qualified staff in
the presence of customers.
3.7 Fan section source side Performance tests comprise the measurement of:
Axial electric fans, protected to IP 54, with external rotor and - electrical data
plastic-coated aluminium blades. Housed in aerodynamic hoods complete - water flow rates
with safety grille. Electric motor with built-in overload protection. - working temperatures
Fans diameter: 450 mm, 800 mm or 910 mm according to the unit's size - power input
and version. - power output
Electric motor with 4 poles, 6 poles or 8 poles according to the unit's size - pressure drops on the water-side exchanger both at full load (at the
and version. conditions of selection and at the most critical conditions for the
- Continuous adjustment of the fan speed on units: condenser) and at part load conditions.
- versions K, sizes 0152P..0352P During performance testing it is also possible to simulate the main alarm
versions LN-K, sizes 0152P..0302P states.
versions SL-K e LN-CA, sizes 0152P..0202P Noise tests are performed to check noise emissions according to
versions CA, sizes 0152P..0262P ISO9614.
- Pressostatic fan’s control:
- versions K sizes 0402P..0802P 3.12 R454B REFRIGERANT
- Adjustment of the fan speed with auto-transformer on units: The refrigerant used in these units is R454B, one of the most
- versions LN-K sizes 0352P..0802P eco-sustainable refrigerants for replacing traditional R410A, thanks to the
versions SL-K sizes 0252P..0802P 76% lower GWP.
versions LN-CA sizes 0252P..0812P Unlike R410A, R454B is classified as A2L according to ISO 817. The first
versions SL-CA, sizes 0152P..0812P digit defines toxicity (A: NON-TOXIC), while the last digits define the
flammability level (2L: MILDLY FLAMMABLE - low burning velocity). It is
3.8 Refrigerant circuit
Main components of the cooling circuit: classified by PED Directive into Group 1.
- single circuit in tandem compressors The main characteristics of this refrigerant and some additional guidelines
- total ratio between refrigerant charge and cooling capacity* lower than are reported below. Despite the minimal risk, the indications provided
0,12 g/W (versions K, LN-K, SL-K, CA) cannot replace a more detailed risk analysis if required, also based on
- total ratio between refrigerant charge and cooling capacity* lower than any regulations in force in the installation area.
0,15 g/W (versions LN-CA, SL-CA) Further and more detailed guidelines are available in the dedicated area
- plate heat exchanger of the website www.melcohit.com (Guidelines) or in the dedicated
- drier filter with replaceable cartridge addendum of the general installation and maintenance manual.
- refrigerant line sight glass with humidity indicator Main characteristics of R454B refrigerant:
- electronic expansion valve - Safety classification (ASHRAE / ISO 817): A2L
- high and low pressure transducers
- high and low pressure safety valves, conveyed to external discharge - PED Group: 1
- safety switching device for limiting the pressure - Ozone Depletion Potential (ODP) (R11=1): 0
- crankcase heater on each compressor - AR5 (AR4) GWP (CO2=1): 467 (466)
- * Cooling capacity according to Eurovent conditions: water(in/out) - Composition (Wt %): 68,9% R32, 31,1% R1234yf
12/7°C, outdoor temperature 35°C - LFL@23°C, 50% RH (% v/v): 11,7
- UFL@23°C, 50% RH (% v/v): 22,0
3.9 Electrical and control panel - Burning velocity (cm/s): 5,2
Electrical and control panel built to EN60204-1 and EC204-1 standards, - Minimum Ignition Energy (mJ) (ASTM E582-13): 100-300
complete with:
-

ELCA_Engine ver.4.2.2.0 3.1.1 NX-G06 0202P - 0812P_201904_EN R454B


UNIT STANDARD COMPOSITION

• All operations on the unit must be performed by trained and qualified


personnel on flammable refrigerants handling, in accordance with the
relevant local standards and codes of practice.
• The refrigerant is heavier than air and can stagnate, reaching a
dangerous concentration. To avoid risks, maintain a safe environment by
ensuring adequate ventilation.
• The units must be installed in such a way as to prevent any refrigerant
leaks from flowing into the buildings or any place where it could cause
damage to people, animals or properties. Pay particular attention to the
presence and disposition of any external air intakes, doors, shutters, etc.
• The units are equipped with conveyed safety valves with external
discharge. In case of over-pressure, refrigerant gas can escape from
these valves: the discharge of these ducts must be directed towards safe
areas and away from the ground or potential sources of ignition.
• Do not braze pipes and components containing refrigerant.
• Do not use flames to cut / open pipes.
• The units are equipped with a safety valve (water side). In case of
breakage of the heat exchanger and resulting overpressure, refrigerant 3.13 KIPlink - Keyboard In your Pocket (option 6196)
gas can escape from these valves: the discharge of these valves must be KIPlink - Keyboard In Your Pocket - is the innovative user interface based
directed towards safe areas and away from the ground or potential on WiFi technology that allows one to operate on the unit directly from the
sources of ignition. smartphone or tablet. Using KIPlink, it is possible to turn the unit on and
• The hydraulic circuit must be designed in such a way as to prevent the off, adjust the set-point, plot the main operating variables, monitor in detail
release of refrigerant gas inside the buildings or in any case in places the status of the refrigerant circuits, the compressors, the fans (if present)
where it can cause damage to people, animals or properties. and the pumps (if present) and display and reset the possible alarms.

3.13 Electronic control W3000 / W3000+


The controller is available in two different versions according to the unit’s
model, both with Compact keyboard:
W3000 : It features an easy-to-use interface and a complete LCD display
that allows consulting and intervening on the unit by means of a
multi-language menu, available in three languages: Italian, English and a
further language among French, Spanish, German, Russian and
Swedish. The clock card allows to consult the alarm history from the
keyboard.
W3000+ : It features an easy-to-use interface and a complete LCD
display that allows consulting and intervening on the unit by means of a
multi-language menu (19 languages are available). The diagnostics
includes a complete alarm management, with the “black-box” and the
alarm history display for enhanced analysis of the unit operation. The
programmable timer manages a weekly schedule organized into time
bands to optimise unit performance by minimising power consumption
during periods of inactivity. Up to 10 daily time bands can be associated
with different operating set points. As option, the KIPlink is available -
Keyboard In Your Pocket - is the innovative user interface based on WiFi
technology that allows one to operate on the unit directly from the
smartphone or tablet.
On both versions, the regulation is based on the patented “Quickmind”
water temperature regulation logic uses self-adapting control to maintain
flow temperatures and optimise performance even in low water content
scenarios. As an alternative, the proportional or proportional-integral
regulations are also available.
Optional proprietary devices can perform the adjustment of the resources
in systems made of several units. Consumption metering and
3.13 Night mode (option 1430)
performance measurement are possible as well. The night mode function allows to reduce the sound power of the unit,
Supervision can be easily developed via proprietary devices or the reducing the speed of the fans and the number of active compressors.
integration in third party systems by means of the most common protocols
as ModBus, Bacnet, Bacnet-over-IP, LonWorks. Compatibility with the 3.13 U.L.C. - User limit control (option 4960)
remote keyboard (up to 8 units). The defrosting (reversible unit only) Guaranteed the start-up of the units with the option U.L.C. even when the
follows a proprietary self-adaptive logic, which features the monitoring of critical working condition could generate an alarm.
several operational parameters, therefore reducing the number and The controller can manage a 3way mixing valve (not provided) by 0-10V
duration of the defrost cycles, with a benefit for the overall energy signal for ensuring a dynamic control of the water temperature on user
efficiency. heat exchanger according to the operating limits allowed. This ensures
the start-up and correct functioning of the unit into the envelope, also
even critical whether condition.

3.14 Versions
/K - Key efficiency, compact version
Key efficiency, compact version.

/LN-K - Low Noise, Key efficiency and compact version


This configuration features a special soundproofing for the compressor
compartment and the pumps (if present), a reduced fan speed and an
oversized condensing section.
The fan speed is automatically increased in case of particularly tough
environmental conditions.

/SL-K - Super Low noise, Key efficiency and compact version

ELCA_Engine ver.4.2.2.0 3.1.2 NX-G06 0202P - 0812P_201904_EN R454B


UNIT STANDARD COMPOSITION

This configuration features a special soundproofing for the compressor


compartment and the pumps (if present), a reduced fan speed and an
oversized condensing section.
The fan speed is automatically increased in case of particularly tough
environmental conditions.

/CA - Class A of efficiency


Class A of efficiency as per Eurovent.

/LN-CA - Low Noise, Class A of efficiency


Unit in Eurovent class A of efficiency.
This configuration features a special soundproofing for the compressor
compartment and the pumps (if present), a reduced fan speed and an
oversized condensing section.
The fan speed is automatically increased in case of particularly tough
environmental conditions.

/SL-CA - Super Low noise, Class A of efficiency


Unit in Eurovent class A of efficiency.
This configuration features a special soundproofing for the compressor
compartment and the pumps (if present), a reduced fan speed and an
oversized condensing section.
The fan speed is automatically increased in case of particularly tough
environmental conditions.

3.15 Configurations
- , standard unit
Standard unit for production of chilled water

/D, unit with partial heat recovery


Unit for the production of chilled water, equipped with an auxiliary heat
exchanger (desuperheater) on the compressor discharge for superheat
recovery. The recovered heat is approximately the 20% of the total
cooling capacity and can be used for domestic hot water production or
other secondary uses, such as the integration of an existing boiler.

ELCA_Engine ver.4.2.2.0 3.1.3 NX-G06 0202P - 0812P_201904_EN R454B


UNIT STANDARD COMPOSITION

The NX-G06 family is developed on two different structures:

Longitudinal V-shaped coil structure Horizontal V-shaped coil structure

The following table shows the structure of all the available NX-G06 sizes/version:
Structure Size
Longitudinal V 202 252 262 302 352 402 452 502 552 602 702 802

Horizontal V 412 462 512 562 612 712 812

(1)
Version Net cooling capacity (kW) - EN14511 -
K 50 56 62 74 85 98 110 122 138 159 182
LN-K 50 56 63 72 86 95 108 120 134 156 172
SL-K 50 56 63 75 85 96 109 119 135 147
CA 53 60 67 81 92 103 117 132 154 171 193 218
LN-CA 53 61 68 79 90 103 115 129 148 166 190 212
SL-CA 53 60 66 79 90 102 114 127 145 165 187 209
(1) Plant (side) cooling exchanger water (in/out) 12°C/7°C; Source (side) heat exchanger air (in) 35°C.

The following table shows the controller of all the available NX-G06 sizes/version:

Size
402 452 502 552 602 702 802
Version 202 252 262 302 352
412 462 512 562 612 712 812
K
LN-K W3000
SL-K
CA W3000+
LN-CA
SL-CA

The following table shows fan diameters (mm), fan motor types and std ventilation controls of all the available NX-G06 sizes/version:

Size
402 452 502 552 602 702 802
Version 202 252 262 302 352
412 462 512 562 612 712 812

Ø450 Ø450 Ø450 Ø450 Ø450 Ø800 Ø800 Ø800 Ø800 Ø800 Ø800 Ø800
K
4 poles 4 poles 4 poles 4 poles 4 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles

Ø450 Ø450 Ø450 Ø450 Ø800 Ø800 Ø910 Ø910 Ø910 Ø800 Ø800 Ø800
LN-K
4 poles 4 poles 4 poles 4 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles

Ø450 Ø800 Ø800 Ø800 Ø910 Ø910 Ø800 Ø800 Ø800 Ø800 Ø800
SL-K
4 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles

Ø450 Ø450 Ø450 Ø800 Ø800 Ø910 Ø910 Ø800 Ø800 Ø800 Ø800 Ø800
CA
4 poles 4 poles 4 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles

Ø450 Ø800 Ø800 Ø800 Ø910 Ø800 Ø800 Ø800 Ø800 Ø800 Ø800 Ø800
LN-CA
4 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 6 poles 8 poles 8 poles 8 poles 8 poles

Ø800 Ø910 Ø910 Ø910 Ø800 Ø800 Ø800 Ø800 Ø800 Ø800 Ø800 Ø800
SL-CA
6 poles 6 poles 6 poles 6 poles 6 poles 8 poles 8 poles 8 poles 8 poles 8 poles 8 poles 8 poles

DVV (p.c.) Fan speed controlled by phase-cut devices

DP Pressostatic fan control (DVV with autotransformers available as option)

DVV (a.t.) Fan speed controlled by autotransformers

Note:
The unit's operating limit depends on its ventilation control. Optional devices are available to enlarge the operating limits.
Please refer to the dedicated data book section and to ElcaWorld selection software.

ELCA_Engine ver.4.2.2.0 3.1.4 NX-G06 0202P - 0812P_201904_EN R454B


4.1 OPTIONS

OPTIONS DESCRIPTIONS BENEFITS AVAILABLE FOR


MODELS
1470
MULTIFUNCTION CARD
1431 The option includes a related controller Night mode is a system setting to limit ALL
NIGHT MODE expansion board and dedicated terminal maximum noise level of the unit. Noise
block (it is necessary to install a 3 way level is reduced limiting maximum
valve). compressor frequency and fan speed.
4951 Water temperature probe on hydraulic The pump activation can be set by ALL
WITH HYDRAULIC decoupler. parameter according to the water
DECOUPLER PROBE temperature on buffer tank measuring by
the sensor (in the systems with the primary
and secondary circuits separated by a
hydraulic decoupler), thus bringing
significant pump consumption reduction
during unit’s stand-by.
4961 Option to be selected with the unit without Guaranteed the start-up of the units with ALL
WITH OR WITHOUT FIX pump/s or with fix speed pump/s the option U.L.C. even when the critical
SPEED PUMP (4703,4706,4707,4711,4712). working condition could generate an
The option includes a related controller alarm.
expansion board and dedicated terminal The W3000TE controller can manage a
block. 3way mixing valve (not provided from
MEHITS) by 0-10V signal for ensuring a
dynamic control of the water temperature
on user heat exchanger according to the
operating limits allowed. This ensures the
start-up and correct functioning of the unit
into the envelope, also even critical
whether condition.
1960
PRESSURE RELIEF VALVES
1961 Dual relief valve with switch Allows to unselect a relief valve in order to ALL
DUAL RELIEF VALVES service the unit avoiding medium or long
WITH SWITCH inoperative periods
380
NUMBERED WIRING
381 Electrical board wires are identified by Facilitate maintainance interventions to the ALL
NUMBERED WIRING ON numbered labels. The reference numbers electrical board connections.
EL. BOARD are indicated in the unit's wiring scheme.
2410
PHASE SEQUENCE RELAY
2411 Relay for checking mains phase-sequence Protects loads against faults due to ALL
WITH EXTERNAL PHASE incorrect connection of mains
SEQUENCE RELAY
3300
COMPRESSOR REPHASING
3301 Capacitors on the compressors' power The unit's average cos(phi) increases. ALL
COMPR.POWER inlet line.
FACTOR CORR.
3410
AUTOMATIC CIRCUIT BREAKERS
3412 Over-current switch on the major electrical In case of overcurrent allows resetting of ALL
AUTOM. CIRCUIT loads. the switch without the replacement of
BREAK. ON LOADS relative fuses.
3600
ON/OFF COMPRESSOR SIGNAL
3601 Auxiliary contacts providing a voltage-free Allows remote signalling of compressor's ALL
COMPRESSOR signal. activation or remote control of any auxiliary
OPERATION SIGNAL loads.
4180
REMOTE CONNECTION ARRANGEMENT
4181 Interface module for ModBUS protocols. Allows integration with BMS operating with ALL
SERIAL CARD MODBUS ModBUS protocol.
4182 Interface module for Echelon systems. Allows integration with BMS operating with ALL
SERIAL CARD FOR LonWorks protocols
LONWORKS

ELCA_Engine ver.4.2.2.0 4.1.1 NX-G06 0202P - 0812P_201904_EN R454B


OPTIONS

OPTIONS DESCRIPTIONS BENEFITS AVAILABLE FOR


MODELS
4184 Interface module for BACnet protocols. Allows integration with BMS operating with ALL
SERIAL CARD BACNET BACnet protocol.
MS/TP RS485
4185 Interface module for BACnet OVER-IP Allows to interconnect BACnet devices ALL
SERIAL CARD FOR protocols. over Internet Protocol within wide-area
BACNET OVER IP networks.
4187 Interface kit for M-Net protocol. Interface module to allow the integration of ALL
M-Net W3000 the unit with Mitsubishi Electric proprietary
INTERFACE KIT communication protocol M-Net.
4188 Interface module for ModBus TCP/IP Allows integration with BMS operating with ALL
SERIAL CARD MODBUS protocol ModBus TCP/IP protocol.
TCP/IP
4189 Interface module for SNMP protocol Allows integration with BMS operating with ALL
SERIAL CARD SNMP SNMP protocol.
6160
AUXILIARY INPUT
6163 4-20 mA analog input + demand limit The 4-20 mA analog input allows to ALL
AUX 4-20mA REMOTE D remote input change the operating set-point according
L.C. to the value of current applied to the
analogue input. The demand limit remote
input permits to limit the unit's power
absorption for safety reasons
6190
TYPE OF VISUAL DISPLAY
6196 The unit is equipped with KIPlink, the ALL
KIPlink innovative user interface based on WiFi
technology
1510
SOFT-STARTER
1511 Electronic device adopted to manage the Break down of the inrush current ALL
UNIT WITH SOFT-START inrush current. compared to the direct motor start, lower
motor windings’ mechanical wear,
avoidance of mains voltage fluctuations
during starting, favourable sizing for the
electrical system.
3430
REFRIGERANT LEAK DETECTOR
3431 Refrigerant leak detection system, It promptly detects gas leakages ALL
REFRIG. LEAK supplied factory mounted and wired in the
DETECTOR electrical board. In case of leak detection it
will raise an alarm.
3433 Refrigerant leak detection system, It promptly detects gas leakages and stops ALL
GAS LEAK CONTACT + supplied factory mountedand wired in the the unit
COMPR. OFF electrical board. In case of leak detection it
will raise an alarm and stop the unit.
6310
VISUAL DISPLAY PROTECTION
6311 Display protection sealed panel Provide complete protection against UV ALL
WITH DISPLAY rays, atmospheric agents, sand storms.
PROTECTION
5940
SETP. COMPENSATION OUT. TEMP.
5941 This option includes an outside air sensor Available as option an outside air ALL
WITH SETPOINT to be installed outside the building and temperature probe to control the system
COMPENSATION enable the climatic curve function. water temperature set point based on
cooling and heating (reversible units)
climatic curves. Delivering water at
different temperatures to the terminals
based on the outside air temperature
achieves high seasonal efficiency ratios
and brings considerable savings in running
costs.

ELCA_Engine ver.4.2.2.0 4.1.2 NX-G06 0202P - 0812P_201904_EN R454B


OPTIONS

OPTIONS DESCRIPTIONS BENEFITS AVAILABLE FOR


MODELS
5920
MANAGEMENT & CONTROL SYSTEMS
5922 This option includes all following devices This accessory allows to acquire the ALL
ClimaPRO ModBUS on-board the unit panel: electrical data and the power absorbed by
RS485 - MID - MID certified network analyzer operating the unit and communicate with ClimaPRO
on ModBUS over RS-485 via high level communication interface
- Current transformers based on ModBUS over EIA RS-485.
- W3000TE controller More specifically, the data collected are:
- Software release LA09 or later version. power supply, current, frequency, power
factor (cosᵩ), electrical power
consumption, energy consumption.
This specific energy meter model is MID
certified and can therefore be used for
billing applications.
This option also ensures the compatibility
between the units and ClimaPRO, thus
allowing ClimaPRO to acquire all the main
unit’s operating variables and status by
means of a high level communication
interface to the controller installed onboard
the unit panel.
5923 This option includes all following devices This accessory allows to acquire the ALL
ClimaPRO BacNET over on-board the unit panel: electrical data and the power absorbed by
IP - network analyzer operating on BACnet the unit and communicate with ClimaPRO
over IP via high level communication interface
- Current transformers based on BACnet over IP.
- W3000TE controller More specifically, the data collected are:
- Software release LA09 or later version. power supply, current, frequency, power
factor (cosᵩ), electrical power
consumption, energy consumption.
This network analyzer is not MID certified
and cannot therefore be used for billing
applications.
This option also ensures the compatibility
between the units and ClimaPRO, thus
allowing ClimaPRO to acquire all the main
unit’s operating variables and status by
means of a high level communication
interface to the controller installed onboard
the unit panel.
5924 This option includes all following devices This accesory allows to acquire the ALL
ENERGY METER FOR on-board the unit panel: electrical data and the power absorbed by
BMS - network analyzer with display operating the unit and send them via RS-485 bus to
on ModBUS protocol over RS-485 (without the BMS for energy metering.
certification MID)
- current transformers.
5925 This option includes all following devices This option allows to acquire the electrical ALL
ENERGY METER FOR on-board the unit panel: data and the power absorbed by the unit.
W3000 - network analyzer with display, already The figures are accessible through the
cabled to unit's controller unit's W3000 interface, and be sent to the
- current transformers. BMS via several protocols by selecting the
dedicated serial card in the option list.
600
LIQUID LINE SOLENOID VALVE
601 Solenoid valve on the refrigerant liquid Intercepts the liquid refrigerant and grants ALL
LIQUID LINE SOLENOID line. the correct operation of the unit in all the
VALVE different operating modes.
1400
HP AND LP GAUGES
1401 High and low pressure gauges Allows immediate reading of the pressure ALL
HP AND LP GAUGES values on both low and high pressure
circuits
1900
COMPRESSOR SUCTION VALVE
1901 Shut-off valve on compressor's suction Simplifies maintenance activities ALL
COMPRESSOR SUCTION circuit.
VALVE

ELCA_Engine ver.4.2.2.0 4.1.3 NX-G06 0202P - 0812P_201904_EN R454B


OPTIONS

OPTIONS DESCRIPTIONS BENEFITS AVAILABLE FOR


MODELS
1910
COMPRESSOR DISCHARGE VALVE
1911 Shut-off solenoid valve on compressor Simplifies maintenance activities ALL
COMPR. DISCHARGE discharge circuit
LINE VALVE
990
CONDENSING COIL
876 The heat exchanger is completely treated Provide a very high resistance against ALL
E-COATING by electrolysis so as to create a protective corrosion, also in very aggressive
MICROCHANNEL COILS layer of epoxy polymer on the surface, with environment.
the following characteristics: For further information please refer to the
- over 3120 hours of salt spray protection Guidelines “Finned coil heat exchangers
as per ASTM G85-02 A3 (SWAAT); and protection against corrosion”,
- polyurethane surface protection against available in the download section of the
UV rays. website
www.melcohit.com/EN/Download/Corporate/GUIDELINES
or contact our sales department.
879 Finned coil heat exchanger made from Provide a good resistance against ALL
COPPER/ALUMINIUM suitably-spaced copper tubes and corrosion.
COILS aluminum fins designed to ensure For further information please refer to the
maximum heat exchange efficiency. Guidelines “Finned coil heat exchangers
and protection against corrosion”,
available in the download section of the
website
www.melcohit.com/EN/Download/Corporate/GUIDELINES
or contact our sales department.
881 Finned coil heat exchanger made from This type of coil is not subject to galvanic ALL
Cu/Cu EXTERNAL COIL suitably-spaced copper tubes and fins corrosion, being made from just one
designed to ensure maximum heat material. For further information please
exchange efficiency. refer to the Guidelines “Finned coil heat
exchangers and protection against
corrosion”, available in the download
section of the website
www.melcohit.com/EN/Download/Corporate/GUIDELINES
or contact our sales department.
894 Finned coil heat exchanger made from Provide a good resistance against ALL
Cu PIPES/PREPAINTED copper tubes and aluminum fins with corrosion.
ALL. FINS chemical cleaning treatment to remove For further information please refer to the
impurities, and then coated with protective Guidelines “Finned coil heat exchangers
paint with the following characteristics: and protection against corrosion”,
- fins treated with protective polyester resin available in the download section of the
paint; website
- over 1000 hours of salt spray protection www.melcohit.com/EN/Download/Corporate/GUIDELINES
as per ASTM B117 (fins without cross and or contact our sales department.
protected edges);
- excellent resistance to UV rays.
895 Copper-aluminum heat exchanger coils Provide a very high resistance against ALL
FIN GUARD SILVER with polyurethane paint Fin Guard Silver corrosion, also in very aggressive
TREATM SB. Coil completely coated by a protective environment.
layer of polyurethane paint with the For further information please refer to the
following characteristics: Guidelines “Finned coil heat exchangers
- polyurethane paint with metallic and protection against corrosion”,
emulsion; available in the download section of the
- over 3000 hours of salt spray protection website
as per ASTM B117; www.melcohit.com/EN/Download/Corporate/GUIDELINES
- excellent resistance to UV rays; or contact our sales department.
- high-pressure spray painting system.
820
FAN CONTROL
801 Pressostatic control of the fans Extension of the unit operating range (see ALL
PRESSOST. LOW the section dedicated to the operating
AMBIENT CONTROL limits). The device allows the unit to
operate in the most extreme conditions
avoiding any risk of low pressure alarm
intervention. The enhanced air flow
management delivers also benefits in
terms of both efficiency and quietness.

ELCA_Engine ver.4.2.2.0 4.1.4 NX-G06 0202P - 0812P_201904_EN R454B


OPTIONS

OPTIONS DESCRIPTIONS BENEFITS AVAILABLE FOR


MODELS
802 Fan speed control according to the Extension of the unit operating range (see ALL
VAR.FAN SPEED LOW condensing pressure; the use of this the section dedicated to the operating
AMB.CONTROL device is mandatory in case the unit limits). The device allows the unit to
operates with low evaporator leaving water operate in the most extreme conditions
temperature combined with low outdoor air avoiding any risk of low pressure alarm
temperatures intervention. The enhanced air flow
management delivers also benefits in
terms of both efficiency and quietness.
808 Electronically commutated fans (EC fans). Reduced energy consumption and ALL
EC FANS The brushless motor, governed by a minimized current's absorption during
special controller, continuously adjust fans' start-up phase. The efficiency is increased
speed. by apporximately: +1% of EER and +4/5%
of ESEER. The noise reduces
proportionally to the unit's partialization.
819 Fan speed control according to the Extension of the unit operating range (see ALL
DVVF condensing pressure; the use of this the section dedicated to the operating
device is mandatory in case the unit limits). The device allows the unit to
operates with low evaporator leaving water operate in the most extreme conditions
temperature combined with low outdoor air avoiding any risk of low pressure alarm
temperatures intervention. The enhanced air flow
management delivers also benefits in
terms of both efficiency and quietness.
821 Fan speed control according to the Extension of the unit operating range (see ALL
DVV2F condensing pressure; the use of this the section dedicated to the operating
device is mandatory in case the unit limits). The device allows the unit to
operates with low evaporator leaving water operate in the most extreme conditions
temperature combined with low outdoor air avoiding any risk of low pressure alarm
temperatures intervention. The enhanced air flow
management delivers also benefits in
terms of both efficiency and quietness.
3160
WITH HYDRAULIC KIT ON BOARD
3152 Hydronic group (see dedicated section). ALL
KIT 1 PUMP 2 POL
LH+TANK
3153 Hydronic group (see dedicated section). ALL
KIT 1 PUMP 2 POL
HH+TANK
3155 Hydronic group (see dedicated section). ALL
KIT 2 PUMPS 2 POL
LH+TANK
3156 Hydronic group (see dedicated section). ALL
KIT 2 PUMPS 2 POL
HH+TANK
3164 Hydronic group (see dedicated section). ALL
KIT 1 PUMP 2 POLES LH
3165 Hydronic group (see dedicated section). ALL
KIT 1 PUMP 2 POLES HH
3167 Hydronic group (see dedicated section). ALL
KIT 2 PUMPS 2 POLES
LH
3168 Hydronic group (see dedicated section). ALL
KIT 2 PUMPS 2 POLES
HH
2430
PIPING KIT ANTIFREEZE HEATER
2432 Electrical heaters on pipes and other It protects the unit against ice formation on ALL
ANTIFREEZE PIPING, hydraulic unit's components. This option is its hydraulic components.
PUMPS mandatory if the unit is supposed to work
with outdoor temperature below 0°C.
2433 Electrical heaters on pipes and other ALL
ANTIFREEZE PIPING, hydraulic unit's components. This option is
PUMPS, TANK mandatory if the unit is supposed to work
with outdoor temperature below 0°C.
2020
ANTI-INTRUSION GRILLS
2021 Anti-intrusions grills Avoid the intrusion of solid bodies into the ALL
ANTI-INTRUSION GRILLS unit's structure.

ELCA_Engine ver.4.2.2.0 4.1.5 NX-G06 0202P - 0812P_201904_EN R454B


OPTIONS

OPTIONS DESCRIPTIONS BENEFITS AVAILABLE FOR


MODELS
9970
PACKING
9971 Unit provided with plastic supports ALL
WITHOUT PACKAGING
9973 Unit provided with wooden cage ALL
WOODEN CAGE
PACKING
9979 Unit provided with container slides and ALL
CONTAINER PACKING covered with nylon
9996 Unit provided with container slides ALL
CONTAINER SLIDES

ELCA_Engine ver.4.2.2.0 4.1.6 NX-G06 0202P - 0812P_201904_EN R454B


OPTIONS

Additional information - IMPORTANT -

381 – Numbered wiring on electrical board


Standard feature.

3412 – Automatic circuit breakers


Standard feature.

3301 – Compressor power factor correction


1511 – Soft starter
There is a mutual exclusion rule between the compressor
rephrasing condensers and the soft start device. When both
accessories are required together, a feasibility analysis is
needed. If the configuration is available as a special execution,
an extra-price may be quoted.

1925-1926 – Electronic expansion valve


601 – Liquid line solenoid valve
The use of the electronic expansion valve entails the selection
of the solenoid valve.

808 - EC fans
This option is available only for /CA, /LN-CA, /SL-CA versions.
These fans are suitable to operate up to 46°C of outdoor
temperature. In case of higher temperatures, fans with oversized
motors must be used. For the quotation of these components,
please contact our sales department.

3431 – Leak detector


3433 - Leak detector + compress. Off
The purpose of these options is to check and raise an alarm
whether a leak occurs; they should not be considered as safety
devices.

1431 – Night Mode


4951 – With hydraulic decoupler probe
4961 – User limit control
1471 - 4951 + 1431
1472 - 4951 + 1431 + 4961
1473 - 4951 + 4961
1474 - 1431 + 4961
These options are available only for /CA, /LN-CA, /SL-CA
versions. On models equipped with 800mm o 910mm fans,
these options entail the selection of EC fans (808).

6196 – Kiplink
6198 – Kiplink + keyboard
5941 – With set point compensation
5925 – Energy meter for W3000
4185 – Serial card BACNET OVER IP
4186 – Serial card KONNEX
4187 – M-net W3000 kit
4188 – Serial card MODBUS TCP/IP
4189 – Serial card SNMP
These options are available only for models equipped with
W3000+ controller.

ELCA_Engine ver.4.2.2.0 4.1.7 NX-G06 0202P - 0812P_201904_EN R454B


OPTIONS

Chiller Plant Control with Active Optimization System

ClimaPRO System Manager

ClimaPRO System Manager represents the state-of-the-art


platform for chiller plant management and control.
ClimaPRO ensures to actively optimize the entire chiller plant
by managing and adjusting each component directly involved in
the production and the distribution of the heating and the cooling
energies, therefore involving chillers and heat pumps, pumping
groups as well as the source-side devices like, for example, the
cooling towers.

In particular, ClimaPRO measures in real-time all the operating


variables from the field, for each individual device and each of
the main system branche, by using serial communication lines
as well as dedicated analogue signals.

The acquired data are then compared with the design data of
each single unit at any different working conditions, thus allowing
to implement control strategies based on dynamic algorithms
which take into account the real operating conditions.

On the basis of these values, an advanced diagnostic module


also allows to assess the level of efficiency for each individual
unit, translating data into easy-to-read information in order to
simplify and optimize the maintenance activities.

The “Chart Builder” software module allows to display the trends


of the main operating variables. The “Reporting” module allows
to send reports to selected users, including data and system’s
status of the main devices as well as to perform calculation of
the energy indexes for each single unit and for the entire chiller
plant.

The accessibility to ClimaPRO System Manager is ensured by


an integrated web server that makes it visible from any computer
equipped with a web browser, either locally or remotely.

ELCA_Engine ver.4.2.2.0 4.1.8 NX-G06 0202P - 0812P_201904_EN R454B


5.1 GENERAL TECHNICAL DATA NX-G06/K
[ SI System ]

NX-G06/K 0202P 0252P 0262P 0302P 0352P 0402P 0452P 0502P 0552P 0602P
Power supply V/ph/Hz 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 49,84 56,52 62,39 74,51 84,98 97,89 109,9 122,3 138,5 159,0
Total power input (1) kW 16,80 19,05 21,78 24,87 29,10 33,00 37,44 41,84 48,66 53,78
EER (1) kW/kW 2,964 2,958 2,862 2,992 2,921 2,967 2,939 2,926 2,844 2,955
ESEER (1) kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 49,70 56,40 62,30 74,40 84,70 97,60 109,6 122,0 138,2 158,7
EER (1)(2) kW/kW 2,920 2,930 2,830 2,960 2,860 2,910 2,880 2,870 2,800 2,910
ESEER (1)(2) kW/kW - - - - - - - - - -
Cooling energy class - - - - - - - - - -
COOLING WITH PARTIAL RECOVERY
Cooling capacity (3) kW 51,71 58,64 64,73 77,31 88,17 101,6 114,0 126,9 143,7 165,0
Total power input (3) kW 16,25 18,42 21,05 24,05 28,13 31,99 36,27 40,52 47,10 52,11
Desuperheater heating capacity (3) kW 14,10 16,11 18,55 20,86 24,64 25,89 29,85 33,78 39,87 42,65
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,383 2,703 2,984 3,563 4,064 4,681 5,255 5,850 6,623 7,605
Pressure drop (1) kPa 33,4 30,8 30,6 31,3 49,9 46,0 47,2 45,2 48,0 45,4
PARTIAL RECOVERY USER SIDE IN REFRIGERATION
Water flow (3) l/s 0,681 0,778 0,895 1,007 1,189 1,250 1,441 1,631 1,924 2,059
Pressure drop (3) kPa 10,6 13,9 18,4 11,4 16,0 17,6 16,5 21,1 19,8 22,6
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2 2 2 2
Number of capacity steps N° 2 2 2 2 2 2 2 2 2 2
No. Circuits N° 1 1 1 1 1 1 1 1 1 1
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50 50 50 50
Refrigerant R454B R454B R454B R454B R454B R454B R454B R454B R454B R454B
Refrigerant charge kg 5,60 7,20 7,30 8,60 9,20 11,0 12,2 12,4 13,9 15,9
Oil charge kg 5,40 5,40 5,40 5,40 5,40 5,40 8,00 10,6 10,6 10,6
Rc (ASHRAE) (4) kg/kW 0,11 0,13 0,12 0,12 0,11 0,11 0,11 0,10 0,10 0,10
FANS
Quantity N° 4 4 4 6 6 2 2 2 2 3
Air flow m³/s 4,92 5,32 5,32 7,41 7,41 11,34 11,34 11,34 11,74 17,04
Fans power input kW 0,25 0,25 0,25 0,25 0,25 2,00 2,00 2,00 2,00 2,00
NOISE LEVEL
Sound Pressure (5) dB(A) 52 52 52 53 54 56 56 56 57 58
Sound power level in cooling (6)(7) dB(A) 84 84 84 85 86 88 88 88 89 90
SIZE AND WEIGHT
A (8) mm 1825 2395 2395 2395 2395 2825 2825 2825 3360 3980
B (8) mm 1195 1195 1195 1195 1195 1195 1195 1195 1195 1195
H (8) mm 1865 1865 1865 1865 1865 1980 1980 1980 1980 1980
Operating weight (8) kg 520 570 580 600 610 700 790 860 930 1060
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511
3 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C; Plant (side) heat exchanger recovery water (in/out) 40,00°C/45,00°C.
4 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
5 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
6 Sound power on the basis of measurements made in compliance with ISO 9614.
7 Sound power level in cooling, outdoors.
8 Unit in standard configuration/execution, without optional accessories.
- Not available
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 5.1.1 NX-G06 0202P - 0812P_201904_EN R454B


GENERAL TECHNICAL DATA NX-G06/K
[ SI System ]

NX-G06/K 0702P
Power supply V/ph/Hz 400/3/50
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 181,9
Total power input (1) kW 63,24
EER (1) kW/kW 2,878
ESEER (1) kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 181,6
EER (1)(2) kW/kW 2,830
ESEER (1)(2) kW/kW -
Cooling energy class -
COOLING WITH PARTIAL RECOVERY
Cooling capacity (3) kW 188,7
Total power input (3) kW 61,23
Desuperheater heating capacity (3) kW 51,09
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 8,698
Pressure drop (1) kPa 45,9
PARTIAL RECOVERY USER SIDE IN REFRIGERATION
Water flow (3) l/s 2,466
Pressure drop (3) kPa 21,8
REFRIGERANT CIRCUIT
Compressors nr. N° 2
Number of capacity steps N° 2
No. Circuits N° 1
Regulation STEPS
Min. capacity step % 50
Refrigerant R454B
Refrigerant charge kg 16,0
Oil charge kg 10,6
Rc (ASHRAE) (4) kg/kW 0,09
FANS
Quantity N° 3
Air flow m³/s 17,04
Fans power input kW 2,00
NOISE LEVEL
Sound Pressure (5) dB(A) 58
Sound power level in cooling (6)(7) dB(A) 90
SIZE AND WEIGHT
A (8) mm 3980
B (8) mm 1195
H (8) mm 1980
Operating weight (8) kg 1080
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511
3 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C; Plant (side) heat exchanger recovery water (in/out) 40,00°C/45,00°C.
4 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
5 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
6 Sound power on the basis of measurements made in compliance with ISO 9614.
7 Sound power level in cooling, outdoors.
8 Unit in standard configuration/execution, without optional accessories.
- Not available
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 5.1.2 NX-G06 0202P - 0812P_201904_EN R454B


GENERAL TECHNICAL DATA NX-G06/LN-K
[ SI System ]

NX-G06/LN-K 0202P 0252P 0262P 0302P 0352P 0402P 0452P 0502P 0552P 0602P
Power supply V/ph/Hz 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 49,63 56,41 62,90 71,67 86,34 95,43 108,3 120,2 134,3 156,3
Total power input (1) kW 17,20 18,90 21,49 26,26 28,90 33,42 36,49 41,05 49,15 53,99
EER (1) kW/kW 2,884 2,984 2,926 2,726 2,986 2,856 2,967 2,925 2,735 2,894
ESEER (1) kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 49,50 56,30 62,80 71,50 86,10 95,20 108,0 119,9 133,9 156,0
EER (1)(2) kW/kW 2,850 2,950 2,890 2,700 2,930 2,810 2,920 2,880 2,690 2,850
ESEER (1)(2) kW/kW - - - - - - - - - -
Cooling energy class - - - - - - - - - -
COOLING WITH PARTIAL RECOVERY
Cooling capacity (3) kW 51,49 58,52 65,26 74,36 89,58 99,01 112,4 124,7 139,3 162,1
Total power input (3) kW 16,63 18,27 20,77 25,37 27,96 32,32 35,29 39,70 47,51 52,22
Desuperheater heating capacity (3) kW 14,46 16,02 18,33 22,58 23,83 27,86 30,52 34,59 41,82 44,98
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,373 2,697 3,008 3,427 4,129 4,564 5,181 5,749 6,422 7,473
Pressure drop (1) kPa 33,1 30,6 31,1 28,9 51,5 43,7 45,9 43,7 45,2 43,9
PARTIAL RECOVERY USER SIDE IN REFRIGERATION
Water flow (3) l/s 0,698 0,773 0,885 1,090 1,150 1,345 1,473 1,670 2,019 2,171
Pressure drop (3) kPa 11,2 13,7 17,9 13,4 14,9 20,4 17,2 22,2 21,8 25,2
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2 2 2 2
Number of capacity steps N° 2 2 2 2 2 2 2 2 2 2
No. Circuits N° 1 1 1 1 1 1 1 1 1 1
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50 50 50 50
Refrigerant R454B R454B R454B R454B R454B R454B R454B R454B R454B R454B
Refrigerant charge kg 6,10 7,50 7,60 8,30 9,80 10,9 12,6 13,6 13,8 15,0
Oil charge kg 5,40 5,40 5,40 5,40 5,40 5,40 8,00 10,6 10,6 10,6
Rc (ASHRAE) (4) kg/kW 0,12 0,13 0,12 0,12 0,11 0,12 0,12 0,11 0,10 0,10
FANS
Quantity N° 4 6 6 6 2 2 2 2 2 3
Air flow m³/s 4,47 5,49 5,49 5,49 8,24 8,24 10,21 10,21 10,21 13,35
Fans power input kW 0,25 0,16 0,16 0,16 1,10 1,10 1,15 1,15 1,15 1,20
NOISE LEVEL
Sound Pressure (5) dB(A) 47 48 48 48 51 51 52 52 52 53
Sound power level in cooling (6)(7) dB(A) 79 80 80 80 83 83 84 84 84 85
SIZE AND WEIGHT
A (8) mm 2395 2395 2395 2395 2825 2825 3360 3360 3360 3980
B (8) mm 1195 1195 1195 1195 1195 1195 1195 1195 1195 1195
H (8) mm 1865 1865 1865 1865 1980 1980 1980 1980 1980 1980
Operating weight (8) kg 570 600 600 610 730 750 920 990 1010 1110
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511
3 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C; Plant (side) heat exchanger recovery water (in/out) 40,00°C/45,00°C.
4 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
5 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
6 Sound power on the basis of measurements made in compliance with ISO 9614.
7 Sound power level in cooling, outdoors.
8 Unit in standard configuration/execution, without optional accessories.
- Not available
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 5.1.3 NX-G06 0202P - 0812P_201904_EN R454B


GENERAL TECHNICAL DATA NX-G06/LN-K
[ SI System ]

NX-G06/LN-K 0702P
Power supply V/ph/Hz 400/3/50
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 172,2
Total power input (1) kW 65,29
EER (1) kW/kW 2,637
ESEER (1) kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 171,9
EER (1)(2) kW/kW 2,600
ESEER (1)(2) kW/kW -
Cooling energy class -
COOLING WITH PARTIAL RECOVERY
Cooling capacity (3) kW 178,7
Total power input (3) kW 63,13
Desuperheater heating capacity (3) kW 55,06
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 8,237
Pressure drop (1) kPa 41,2
PARTIAL RECOVERY USER SIDE IN REFRIGERATION
Water flow (3) l/s 2,658
Pressure drop (3) kPa 25,4
REFRIGERANT CIRCUIT
Compressors nr. N° 2
Number of capacity steps N° 2
No. Circuits N° 1
Regulation STEPS
Min. capacity step % 50
Refrigerant R454B
Refrigerant charge kg 15,4
Oil charge kg 10,6
Rc (ASHRAE) (4) kg/kW 0,09
FANS
Quantity N° 3
Air flow m³/s 13,35
Fans power input kW 1,20
NOISE LEVEL
Sound Pressure (5) dB(A) 53
Sound power level in cooling (6)(7) dB(A) 85
SIZE AND WEIGHT
A (8) mm 3980
B (8) mm 1195
H (8) mm 1980
Operating weight (8) kg 1120
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511
3 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C; Plant (side) heat exchanger recovery water (in/out) 40,00°C/45,00°C.
4 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
5 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
6 Sound power on the basis of measurements made in compliance with ISO 9614.
7 Sound power level in cooling, outdoors.
8 Unit in standard configuration/execution, without optional accessories.
- Not available
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 5.1.4 NX-G06 0202P - 0812P_201904_EN R454B


GENERAL TECHNICAL DATA NX-G06/SL-K
[ SI System ]

NX-G06/SL-K 0202P 0252P 0262P 0302P 0352P 0402P 0452P 0502P 0552P 0602P
Power supply V/ph/Hz 400/3+N/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 50,18 56,53 63,24 74,64 84,96 96,00 108,9 119,4 134,9 146,9
Total power input (1) kW 16,89 18,86 21,28 25,45 28,35 32,57 36,52 41,57 48,74 57,31
EER (1) kW/kW 2,970 2,989 2,967 2,925 3,004 2,945 2,984 2,870 2,770 2,564
ESEER (1) kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 50,10 56,40 63,10 74,50 84,70 95,70 108,6 119,0 134,5 146,5
EER (1)(2) kW/kW 2,930 2,960 2,930 2,900 2,940 2,900 2,930 2,830 2,720 2,530
ESEER (1)(2) kW/kW - - - - - - - - - -
Cooling energy class - - - - - - - - - -
COOLING WITH PARTIAL RECOVERY
Cooling capacity (3) kW 52,07 58,65 65,61 77,44 88,14 99,60 113,0 123,8 139,9 152,4
Total power input (3) kW 16,33 18,25 20,59 24,61 27,41 31,49 35,32 40,19 47,12 55,39
Desuperheater heating capacity (3) kW 14,22 15,50 17,66 21,38 23,89 27,67 30,59 35,10 41,09 48,74
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,400 2,703 3,024 3,569 4,063 4,591 5,207 5,708 6,449 7,023
Pressure drop (1) kPa 33,9 30,8 31,4 31,4 49,8 44,3 46,4 43,1 45,5 38,7
PARTIAL RECOVERY USER SIDE IN REFRIGERATION
Water flow (3) l/s 0,686 0,748 0,852 1,032 1,153 1,335 1,477 1,694 1,984 2,353
Pressure drop (3) kPa 10,8 12,8 16,6 12,0 15,0 20,1 17,3 22,8 21,0 29,6
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2 2 2 2
Number of capacity steps N° 2 2 2 2 2 2 2 2 2 2
No. Circuits N° 1 1 1 1 1 1 1 1 1 1
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50 50 50 50
Refrigerant R454B R454B R454B R454B R454B R454B R454B R454B R454B R454B
Refrigerant charge kg 7,00 7,30 8,60 10,0 10,3 12,2 14,0 15,0 15,1 15,4
Oil charge kg 5,40 5,40 5,40 5,40 5,40 5,40 8,00 10,6 10,6 10,6
Rc (ASHRAE) (4) kg/kW 0,14 0,13 0,14 0,14 0,12 0,13 0,13 0,13 0,11 0,11
FANS
Quantity N° 6 2 2 2 2 2 3 3 3 3
Air flow m³/s 4,66 6,50 6,50 6,50 8,46 8,46 9,88 9,88 10,74 10,74
Fans power input kW 0,16 0,75 0,75 0,75 0,79 0,79 0,75 0,75 0,90 0,90
NOISE LEVEL
Sound Pressure (5) dB(A) 45 46 46 46 47 48 49 49 50 50
Sound power level in cooling (6)(7) dB(A) 77 78 78 78 79 80 81 81 82 82
SIZE AND WEIGHT
A (8) mm 2395 2825 2825 2825 3360 3360 3980 3980 3980 3980
B (8) mm 1195 1195 1195 1195 1195 1195 1195 1195 1195 1195
H (8) mm 1865 1980 1980 1980 1980 1980 1980 1980 1980 1980
Operating weight (8) kg 590 700 710 710 810 830 990 1060 1070 1110
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511
3 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C; Plant (side) heat exchanger recovery water (in/out) 40,00°C/45,00°C.
4 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
5 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
6 Sound power on the basis of measurements made in compliance with ISO 9614.
7 Sound power level in cooling, outdoors.
8 Unit in standard configuration/execution, without optional accessories.
- Not available
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 5.1.5 NX-G06 0202P - 0812P_201904_EN R454B


GENERAL TECHNICAL DATA NX-G06/CA
[ SI System ]

NX-G06/CA 0202P 0252P 0262P 0302P 0352P 0402P 0452P 0502P 0562P 0612P
Power supply V/ph/Hz 400/3+N/50 400/3+N/50 400/3+N/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 52,80 59,95 66,81 81,64 92,73 103,6 117,0 132,3 153,9 171,3
Total power input (1) kW 15,59 17,95 20,27 24,80 28,22 31,39 35,66 39,89 45,80 51,88
EER (1) kW/kW 3,385 3,352 3,291 3,290 3,287 3,299 3,277 3,316 3,360 3,301
ESEER (1) kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 52,70 59,80 66,70 81,40 92,40 103,3 116,8 132,0 153,6 171,0
EER (1)(2) kW/kW 3,330 3,290 3,240 3,240 3,200 3,230 3,210 3,250 3,290 3,240
ESEER (1)(2) kW/kW - - - - - - - - - -
Cooling energy class - - - - - - - - - -
COOLING WITH PARTIAL RECOVERY
Cooling capacity (3) kW 54,78 62,20 69,32 84,71 96,21 107,5 121,4 137,2 159,7 177,7
Total power input (3) kW 15,10 17,37 19,62 24,07 27,37 30,42 34,54 38,70 44,48 50,34
Desuperheater heating capacity (3) kW 12,58 14,68 16,76 18,57 21,62 24,74 28,55 30,25 33,74 39,17
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,525 2,867 3,195 3,904 4,435 4,956 5,597 6,326 7,361 8,191
Pressure drop (1) kPa 37,5 34,6 35,1 37,5 59,4 51,6 53,6 52,9 59,3 52,7
PARTIAL RECOVERY USER SIDE IN REFRIGERATION
Water flow (3) l/s 0,607 0,709 0,809 0,896 1,044 1,194 1,378 1,460 1,629 1,891
Pressure drop (3) kPa 8,44 11,5 15,0 9,07 12,3 16,1 15,1 16,9 14,2 19,1
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2 2 2 2
Number of capacity steps N° 2 2 2 2 2 2 2 2 2 2
No. Circuits N° 1 1 1 1 1 1 1 1 1 1
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50 50 50 50
Refrigerant R454B R454B R454B R454B R454B R454B R454B R454B R454B R454B
Refrigerant charge kg 7,30 7,90 8,00 9,30 12,4 12,5 12,9 17,5 19,8 20,3
Oil charge kg 5,40 5,40 5,40 5,40 5,40 5,40 8,00 10,6 10,6 10,6
Rc (ASHRAE) (4) kg/kW 0,14 0,13 0,12 0,12 0,14 0,12 0,11 0,13 0,13 0,12
FANS
Quantity N° 6 6 6 2 2 2 2 3 4 4
Air flow m³/s 7,41 7,41 7,41 11,34 11,74 12,53 12,53 17,04 22,68 22,68
Fans power input kW 0,25 0,25 0,25 2,00 2,00 1,84 1,84 2,00 2,00 2,00
NOISE LEVEL
Sound Pressure (5) dB(A) 53 53 54 56 56 58 58 58 59 59
Sound power level in cooling (6)(7) dB(A) 85 85 86 88 88 90 90 90 91 91
SIZE AND WEIGHT
A (8) mm 2395 2395 2395 2825 3360 3360 3360 3980 3160 3160
B (8) mm 1195 1195 1195 1195 1195 1195 1195 1195 2250 2250
H (8) mm 1865 1865 1865 1980 1980 1980 1980 1980 2170 2170
Operating weight (8) kg 580 590 600 710 780 830 920 1060 1460 1480
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511
3 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C; Plant (side) heat exchanger recovery water (in/out) 40,00°C/45,00°C.
4 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
5 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
6 Sound power on the basis of measurements made in compliance with ISO 9614.
7 Sound power level in cooling, outdoors.
8 Unit in standard configuration/execution, without optional accessories.
- Not available
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 5.1.6 NX-G06 0202P - 0812P_201904_EN R454B


GENERAL TECHNICAL DATA NX-G06/CA
[ SI System ]

NX-G06/CA 0712P 0812P


Power supply V/ph/Hz 400/3/50 400/3/50
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 193,2 218,0
Total power input (1) kW 59,31 65,98
EER (1) kW/kW 3,258 3,303
ESEER (1) kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 192,8 217,6
EER (1)(2) kW/kW 3,200 3,240
ESEER (1)(2) kW/kW - -
Cooling energy class - -
COOLING WITH PARTIAL RECOVERY
Cooling capacity (3) kW 200,4 226,2
Total power input (3) kW 57,51 64,02
Desuperheater heating capacity (3) kW 45,80 49,97
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 9,237 10,43
Pressure drop (1) kPa 51,8 65,9
PARTIAL RECOVERY USER SIDE IN REFRIGERATION
Water flow (3) l/s 2,211 2,412
Pressure drop (3) kPa 17,5 20,9
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2
Number of capacity steps N° 2 2
No. Circuits N° 1 1
Regulation STEPS STEPS
Min. capacity step % 50 50
Refrigerant R454B R454B
Refrigerant charge kg 20,8 23,0
Oil charge kg 10,6 10,6
Rc (ASHRAE) (4) kg/kW 0,11 0,11
FANS
Quantity N° 4 5
Air flow m³/s 22,68 28,35
Fans power input kW 2,00 2,00
NOISE LEVEL
Sound Pressure (5) dB(A) 60 61
Sound power level in cooling (6)(7) dB(A) 92 93
SIZE AND WEIGHT
A (8) mm 3160 4335
B (8) mm 2250 2250
H (8) mm 2170 2170
Operating weight (8) kg 1490 1750
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511
3 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C; Plant (side) heat exchanger recovery water (in/out) 40,00°C/45,00°C.
4 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
5 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
6 Sound power on the basis of measurements made in compliance with ISO 9614.
7 Sound power level in cooling, outdoors.
8 Unit in standard configuration/execution, without optional accessories.
- Not available
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 5.1.7 NX-G06 0202P - 0812P_201904_EN R454B


GENERAL TECHNICAL DATA NX-G06/LN-CA
[ SI System ]

NX-G06/LN-CA 0202P 0252P 0262P 0302P 0352P 0402P 0452P 0502P 0562P 0612P
Power supply V/ph/Hz 400/3+N/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 52,81 60,95 67,86 79,36 90,65 103,1 115,8 128,8 147,8 165,8
Total power input (1) kW 15,98 18,19 20,40 24,17 27,31 31,02 35,29 39,35 43,82 50,64
EER (1) kW/kW 3,300 3,352 3,328 3,281 3,322 3,326 3,280 3,277 3,374 3,277
ESEER (1) kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 52,70 60,80 67,70 79,20 90,30 102,8 115,4 128,5 147,5 165,5
EER (1)(2) kW/kW 3,250 3,300 3,270 3,230 3,240 3,250 3,210 3,210 3,300 3,220
ESEER (1)(2) kW/kW - - - - - - - - - -
Cooling energy class - - - - - - - - - -
COOLING WITH PARTIAL RECOVERY
Cooling capacity (3) kW 54,79 63,24 70,40 82,33 94,05 107,0 120,2 133,7 153,3 172,1
Total power input (3) kW 15,46 17,63 19,76 23,41 26,44 30,05 34,17 38,10 42,42 49,00
Desuperheater heating capacity (3) kW 13,41 14,27 16,25 19,62 22,33 24,75 28,56 31,91 35,80 41,88
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,525 2,915 3,245 3,795 4,335 4,932 5,538 6,160 7,067 7,931
Pressure drop (1) kPa 37,5 35,8 36,2 35,5 56,8 51,1 52,5 50,2 54,7 49,4
PARTIAL RECOVERY USER SIDE IN REFRIGERATION
Water flow (3) l/s 0,647 0,689 0,784 0,947 1,078 1,194 1,379 1,540 1,728 2,022
Pressure drop (3) kPa 9,60 10,9 14,1 10,1 13,1 16,1 15,1 18,8 15,9 21,8
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2 2 2 2
Number of capacity steps N° 2 2 2 2 2 2 2 2 2 2
No. Circuits N° 1 1 1 1 1 1 1 1 1 1
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50 50 50 50
Refrigerant R454B R454B R454B R454B R454B R454B R454B R454B R454B R454B
Refrigerant charge kg 7,20 8,00 10,3 10,4 11,3 13,1 13,1 14,1 23,6 23,7
Oil charge kg 5,40 5,40 5,40 5,40 5,40 5,40 8,00 10,6 10,6 10,6
Rc (ASHRAE) (4) kg/kW 0,14 0,13 0,15 0,13 0,13 0,13 0,11 0,11 0,16 0,14
FANS
Quantity N° 6 2 2 2 2 3 3 3 4 4
Air flow m³/s 5,49 8,24 8,24 8,70 10,21 12,35 12,35 13,35 16,85 16,85
Fans power input kW 0,16 1,10 1,10 1,10 1,15 1,10 1,10 1,20 0,93 0,93
NOISE LEVEL
Sound Pressure (5) dB(A) 48 49 49 50 52 52 52 53 54 54
Sound power level in cooling (6)(7) dB(A) 80 81 81 82 84 84 84 85 86 86
SIZE AND WEIGHT
A (8) mm 2395 2825 2825 3360 3360 3980 3980 3980 3160 3160
B (8) mm 1195 1195 1195 1195 1195 1195 1195 1195 2250 2250
H (8) mm 1865 1980 1980 1980 1980 1980 1980 1980 2170 2170
Operating weight (8) kg 590 700 710 780 820 920 990 1070 1460 1480
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511
3 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C; Plant (side) heat exchanger recovery water (in/out) 40,00°C/45,00°C.
4 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
5 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
6 Sound power on the basis of measurements made in compliance with ISO 9614.
7 Sound power level in cooling, outdoors.
8 Unit in standard configuration/execution, without optional accessories.
- Not available
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 5.1.8 NX-G06 0202P - 0812P_201904_EN R454B


GENERAL TECHNICAL DATA NX-G06/LN-CA
[ SI System ]

NX-G06/LN-CA 0712P 0812P


Power supply V/ph/Hz 400/3/50 400/3/50
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 190,4 212,4
Total power input (1) kW 56,55 62,85
EER (1) kW/kW 3,364 3,382
ESEER (1) kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 190,1 212,0
EER (1)(2) kW/kW 3,310 3,310
ESEER (1)(2) kW/kW - -
Cooling energy class - -
COOLING WITH PARTIAL RECOVERY
Cooling capacity (3) kW 197,6 220,3
Total power input (3) kW 54,74 60,84
Desuperheater heating capacity (3) kW 46,33 51,12
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 9,106 10,16
Pressure drop (1) kPa 50,3 62,6
PARTIAL RECOVERY USER SIDE IN REFRIGERATION
Water flow (3) l/s 2,236 2,468
Pressure drop (3) kPa 18,0 21,9
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2
Number of capacity steps N° 2 2
No. Circuits N° 1 1
Regulation STEPS STEPS
Min. capacity step % 50 50
Refrigerant R454B R454B
Refrigerant charge kg 23,8 25,7
Oil charge kg 10,6 10,6
Rc (ASHRAE) (4) kg/kW 0,13 0,12
FANS
Quantity N° 5 6
Air flow m³/s 21,06 25,28
Fans power input kW 0,93 0,93
NOISE LEVEL
Sound Pressure (5) dB(A) 55 56
Sound power level in cooling (6)(7) dB(A) 87 88
SIZE AND WEIGHT
A (8) mm 4335 4335
B (8) mm 2250 2250
H (8) mm 2170 2170
Operating weight (8) kg 1730 1810
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511
3 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C; Plant (side) heat exchanger recovery water (in/out) 40,00°C/45,00°C.
4 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
5 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
6 Sound power on the basis of measurements made in compliance with ISO 9614.
7 Sound power level in cooling, outdoors.
8 Unit in standard configuration/execution, without optional accessories.
- Not available
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 5.1.9 NX-G06 0202P - 0812P_201904_EN R454B


GENERAL TECHNICAL DATA NX-G06/SL-CA
[ SI System ]

NX-G06/SL-CA 0202P 0252P 0262P 0302P 0352P 0412P 0462P 0512P 0562P 0612P
Power supply V/ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 53,11 59,72 66,44 78,67 90,71 101,8 113,9 127,7 145,6 165,4
Total power input (1) kW 15,93 17,65 19,87 23,73 27,54 30,10 34,29 38,87 43,94 49,10
EER (1) kW/kW 3,340 3,373 3,337 3,321 3,298 3,382 3,321 3,283 3,317 3,369
ESEER (1) kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 53,00 59,60 66,30 78,50 90,40 101,5 113,5 127,4 145,3 165,1
EER (1)(2) kW/kW 3,280 3,330 3,290 3,260 3,220 3,310 3,250 3,220 3,250 3,310
ESEER (1)(2) kW/kW - - - - - - - - - -
Cooling energy class - - - - - - - - - -
COOLING WITH PARTIAL RECOVERY
Cooling capacity (3) kW 55,10 61,96 68,93 81,62 94,12 105,6 118,2 132,5 151,0 171,6
Total power input (3) kW 15,42 17,09 19,23 22,95 26,65 29,12 33,16 37,58 42,49 47,49
Desuperheater heating capacity (3) kW 12,88 14,35 16,32 19,77 22,57 25,05 28,79 32,87 36,94 41,10
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,540 2,856 3,177 3,762 4,338 4,867 5,447 6,106 6,962 7,911
Pressure drop (1) kPa 38,0 34,4 34,7 34,9 56,8 49,7 50,8 49,3 53,1 49,1
PARTIAL RECOVERY USER SIDE IN REFRIGERATION
Water flow (3) l/s 0,622 0,693 0,788 0,954 1,090 1,209 1,390 1,587 1,783 1,984
Pressure drop (3) kPa 8,85 11,0 14,2 10,3 13,4 16,5 15,3 20,0 17,0 21,0
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2 2 2 2
Number of capacity steps N° 2 2 2 2 2 2 2 2 2 2
No. Circuits N° 1 1 1 1 1 1 1 1 1 1
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50 50 50 50
Refrigerant R454B R454B R454B R454B R454B R454B R454B R454B R454B R454B
Refrigerant charge kg 7,70 9,00 9,70 9,80 11,7 14,2 14,9 17,4 21,6 23,5
Oil charge kg 5,40 5,40 5,40 5,40 5,40 5,40 8,00 10,6 10,6 10,6
Rc (ASHRAE) (4) kg/kW 0,15 0,15 0,15 0,13 0,13 0,14 0,13 0,14 0,15 0,14
FANS
Quantity N° 2 2 2 2 3 4 4 4 5 6
Air flow m³/s 6,50 8,46 8,46 8,46 9,88 12,20 12,20 12,20 15,25 18,30
Fans power input kW 0,75 0,79 0,79 0,79 0,75 0,51 0,51 0,51 0,51 0,51
NOISE LEVEL
Sound Pressure (5) dB(A) 46 47 47 47 48 49 50 50 51 52
Sound power level in cooling (6)(7) dB(A) 78 79 79 79 80 81 82 82 83 84
SIZE AND WEIGHT
A (8) mm 2825 3360 3360 3360 3980 3160 3160 3160 4335 4335
B (8) mm 1195 1195 1195 1195 1195 2250 2250 2250 2250 2250
H (8) mm 1980 1980 1980 1980 1980 2170 2170 2170 2170 2170
Operating weight (8) kg 700 790 800 810 890 1280 1370 1440 1690 1750
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511
3 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C; Plant (side) heat exchanger recovery water (in/out) 40,00°C/45,00°C.
4 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
5 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
6 Sound power on the basis of measurements made in compliance with ISO 9614.
7 Sound power level in cooling, outdoors.
8 Unit in standard configuration/execution, without optional accessories.
- Not available
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 5.1.10 NX-G06 0202P - 0812P_201904_EN R454B


GENERAL TECHNICAL DATA NX-G06/SL-CA
[ SI System ]

NX-G06/SL-CA 0712P 0812P


Power supply V/ph/Hz 400/3/50 400/3/50
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 187,1 208,9
Total power input (1) kW 57,20 63,36
EER (1) kW/kW 3,271 3,295
ESEER (1) kW/kW
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 186,7 208,5
EER (1)(2) kW/kW 3,220 3,230
ESEER (1)(2) kW/kW - -
Cooling energy class - -
COOLING WITH PARTIAL RECOVERY
Cooling capacity (3) kW 194,1 216,7
Total power input (3) kW 55,30 61,27
Desuperheater heating capacity (3) kW 48,32 53,37
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 8,945 9,989
Pressure drop (1) kPa 48,5 60,5
PARTIAL RECOVERY USER SIDE IN REFRIGERATION
Water flow (3) l/s 2,333 2,576
Pressure drop (3) kPa 19,5 23,8
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2
Number of capacity steps N° 2 2
No. Circuits N° 1 1
Regulation STEPS STEPS
Min. capacity step % 50 50
Refrigerant R454B R454B
Refrigerant charge kg 23,6 27,0
Oil charge kg 10,6 10,6
Rc (ASHRAE) (4) kg/kW 0,13 0,13
FANS
Quantity N° 6 7
Air flow m³/s 18,30 21,35
Fans power input kW 0,51 0,51
NOISE LEVEL
Sound Pressure (5) dB(A) 53 54
Sound power level in cooling (6)(7) dB(A) 85 86
SIZE AND WEIGHT
A (8) mm 4335 5510
B (8) mm 2250 2250
H (8) mm 2170 2170
Operating weight (8) kg 1770 2070
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511
3 Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C; Plant (side) heat exchanger recovery water (in/out) 40,00°C/45,00°C.
4 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
5 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
6 Sound power on the basis of measurements made in compliance with ISO 9614.
7 Sound power level in cooling, outdoors.
8 Unit in standard configuration/execution, without optional accessories.
- Not available
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 5.1.11 NX-G06 0202P - 0812P_201904_EN R454B


6.1 TECHNICAL DATA SEASONAL
EFFICIENCY IN COOLING (EN14825
VALUE)
[ SI System ]
ENERGY EFFICIENCY

SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281)


Ambient refrigeration

NX-G06/K 0202P 0252P 0262P 0302P 0352P 0402P 0452P 0502P 0552P 0602P
Prated,c (1) kW 49,7 56,4 62,3 74,4 84,7 97,6 109,6 122,0 138,2 158,7
SEER (1) (2) - 4,01 4,07 4,02 4,00 4,05 3,87 3,85 3,85 3,90 3,86
Performance ηs (1) (3) % 157,0 160,0 158,0 157,0 159,0 152,0 151,0 151,0 153,0 151,0
NX-G06/K 0702P
Prated,c (1) kW 181,6
SEER (1) (2) - 3,88
Performance ηs (1) (3) % 152,0

NX-G06/LN-K 0202P 0252P 0262P 0302P 0352P 0402P 0452P 0502P 0552P 0602P
Prated,c (1) kW 49,5 56,3 62,8 71,5 86,1 95,2 108,0 119,9 133,9 156,0
SEER (1) (2) - 4,01 4,06 4,07 3,98 3,88 3,88 3,94 3,96 3,99 3,93
Performance ηs (1) (3) % 157,0 159,0 160,0 156,0 152,0 152,0 155,0 155,0 157,0 154,0
NX-G06/LN-K 0702P
Prated,c (1) kW 171,9
SEER (1) (2) - 3,86
Performance ηs (1) (3) % 151,0

NX-G06/SL-K 0202P 0252P 0262P 0302P 0352P 0402P 0452P 0502P 0552P 0602P
Prated,c (1) kW 50,1 56,4 63,1 74,5 84,7 95,7 108,6 119,0 134,5 146,5
SEER (1) (2) - 4,06 3,89 3,89 3,96 3,97 4,00 4,00 3,94 3,94 3,86
Performance ηs (1) (3) % 160,0 153,0 152,0 155,0 156,0 157,0 157,0 155,0 155,0 151,0

NX-G06/CA 0202P 0252P 0262P 0302P 0352P 0402P 0452P 0502P 0562P 0612P
Prated,c (1) kW 52,7 59,8 66,7 81,4 92,4 103,3 116,8 132,0 153,6 171,0
SEER (1) (2) - 4,05 4,12 4,16 3,97 3,95 4,02 4,12 3,99 3,99 4,03
Performance ηs (1) (3) % 159,0 162,0 163,0 156,0 155,0 158,0 162,0 157,0 157,0 158,0
NX-G06/CA 0712P 0812P
Prated,c (1) kW 192,8 217,6
SEER (1) (2) - 4,12 3,94
Performance ηs (1) (3) % 162,0 155,0

NX-G06/LN-CA 0202P 0252P 0262P 0302P 0352P 0402P 0452P 0502P 0562P 0612P
Prated,c (1) kW 52,7 60,8 67,7 79,2 90,3 102,8 115,4 128,5 147,5 165,5
SEER (1) (2) - 4,12 3,89 3,92 3,99 4,03 3,91 4,00 4,00 4,27 4,17
Performance ηs (1) (3) % 162,0 153,0 154,0 156,0 158,0 153,0 157,0 157,0 168,0 164,0
NX-G06/LN-CA 0712P 0812P
Prated,c (1) kW 190,1 212,0
SEER (1) (2) - 4,36 4,14
Performance ηs (1) (3) % 171,0 162,0

NX-G06/SL-CA 0202P 0252P 0262P 0302P 0352P 0412P 0462P 0512P 0562P 0612P
Prated,c (1) kW 53,0 59,6 66,3 78,5 90,4 101,5 113,5 127,4 145,3 165,1
SEER (1) (2) - 3,99 3,99 4,05 4,20 4,06 4,16 4,22 4,25 4,30 4,30
Performance ηs (1) (3) % 157,0 157,0 159,0 165,0 159,0 163,0 166,0 167,0 169,0 169,0
NX-G06/SL-CA 0712P 0812P
Prated,c (1) kW 186,7 208,5
SEER (1) (2) - 4,41 4,21
Performance ηs (1) (3) % 173,0 165,0

Notes:
(1) Parameter calculated according to [REGULATION (EU) N. 2016/2281]
(2) Seasonal energy efficiency ratio
(3) Seasonal space cooling energy efficiency
The units highlighted in this publication contain R454B [GWP100 466] fluorinated greenhouse gases.
Certified data in EUROVENT

ELCA_Engine ver.4.2.2.0 6.1.1 NX-G06 0202P - 0812P_201904_EN R454B


7.1 OPERATING LIMITS

ELCA_Engine ver.4.2.2.0 7.1.1 NX-G06 0202P - 0812P_201904_EN R454B


OPERATING LIMITS NX-G06 0202P - 0812P

SIZE
NX-G06 /K /0202P NX-G06 /LN-CA /0712P
NX-G06 /K /0252P NX-G06 /LN-CA /0812P
NX-G06 /K /0262P NX-G06 /SL-CA /0202P
NX-G06 /K /0302P NX-G06 /SL-CA /0252P
NX-G06 /K /0352P NX-G06 /SL-CA /0262P
NX-G06 /K /0402P NX-G06 /SL-CA /0302P
NX-G06 /K /0452P NX-G06 /SL-CA /0352P
NX-G06 /K /0502P NX-G06 /SL-CA /0412P
NX-G06 /K /0552P NX-G06 /SL-CA /0462P
NX-G06 /K /0602P NX-G06 /SL-CA /0512P
NX-G06 /K /0702P NX-G06 /SL-CA /0562P
NX-G06 /LN-K /0202P NX-G06 /SL-CA /0612P
NX-G06 /LN-K /0252P NX-G06 /SL-CA /0712P
NX-G06 /LN-K /0262P NX-G06 /SL-CA /0812P
NX-G06 /LN-K /0302P
NX-G06 /LN-K /0352P
NX-G06 /LN-K /0402P
NX-G06 /LN-K /0452P
NX-G06 /LN-K /0502P
NX-G06 /LN-K /0552P
NX-G06 /LN-K /0602P
NX-G06 /LN-K /0702P
NX-G06 /SL-K /0202P
NX-G06 /SL-K /0252P
NX-G06 /SL-K /0262P
NX-G06 /SL-K /0302P
NX-G06 /SL-K /0352P
NX-G06 /SL-K /0402P
NX-G06 /SL-K /0452P
NX-G06 /SL-K /0502P
NX-G06 /SL-K /0552P
NX-G06 /SL-K /0602P
NX-G06 /CA /0202P
NX-G06 /CA /0252P
NX-G06 /CA /0262P
NX-G06 /CA /0302P
NX-G06 /CA /0352P
NX-G06 /CA /0402P
NX-G06 /CA /0452P
NX-G06 /CA /0502P
NX-G06 /CA /0562P
NX-G06 /CA /0612P
NX-G06 /CA /0712P
NX-G06 /CA /0812P
NX-G06 /LN-CA /0202P
NX-G06 /LN-CA /0252P
NX-G06 /LN-CA /0262P
NX-G06 /LN-CA /0302P
NX-G06 /LN-CA /0352P
NX-G06 /LN-CA /0402P
NX-G06 /LN-CA /0452P
NX-G06 /LN-CA /0502P
NX-G06 /LN-CA /0562P
NX-G06 /LN-CA /0612P

ELCA_Engine ver.4.2.2.0 7.1.2 NX-G06 0202P - 0812P_201904_EN R454B


OPERATING LIMITS

ELCA_Engine ver.4.2.2.0 7.1.3 NX-G06 0202P - 0812P_201904_EN R454B


OPERATING LIMITS NX-G06 0202P - 0812P

SIZE
NX-G06 /D /K /0202P NX-G06 /D /LN-CA /0712P
NX-G06 /D /K /0252P NX-G06 /D /LN-CA /0812P
NX-G06 /D /K /0262P NX-G06 /D /SL-CA /0202P
NX-G06 /D /K /0302P NX-G06 /D /SL-CA /0252P
NX-G06 /D /K /0352P NX-G06 /D /SL-CA /0262P
NX-G06 /D /K /0402P NX-G06 /D /SL-CA /0302P
NX-G06 /D /K /0452P NX-G06 /D /SL-CA /0352P
NX-G06 /D /K /0502P NX-G06 /D /SL-CA /0412P
NX-G06 /D /K /0552P NX-G06 /D /SL-CA /0462P
NX-G06 /D /K /0602P NX-G06 /D /SL-CA /0512P
NX-G06 /D /K /0702P NX-G06 /D /SL-CA /0562P
NX-G06 /D /LN-K /0202P NX-G06 /D /SL-CA /0612P
NX-G06 /D /LN-K /0252P NX-G06 /D /SL-CA /0712P
NX-G06 /D /LN-K /0262P NX-G06 /D /SL-CA /0812P
NX-G06 /D /LN-K /0302P
NX-G06 /D /LN-K /0352P
NX-G06 /D /LN-K /0402P
NX-G06 /D /LN-K /0452P
NX-G06 /D /LN-K /0502P
NX-G06 /D /LN-K /0552P
NX-G06 /D /LN-K /0602P
NX-G06 /D /LN-K /0702P
NX-G06 /D /SL-K /0202P
NX-G06 /D /SL-K /0252P
NX-G06 /D /SL-K /0262P
NX-G06 /D /SL-K /0302P
NX-G06 /D /SL-K /0352P
NX-G06 /D /SL-K /0402P
NX-G06 /D /SL-K /0452P
NX-G06 /D /SL-K /0502P
NX-G06 /D /SL-K /0552P
NX-G06 /D /SL-K /0602P
NX-G06 /D /CA /0202P
NX-G06 /D /CA /0252P
NX-G06 /D /CA /0262P
NX-G06 /D /CA /0302P
NX-G06 /D /CA /0352P
NX-G06 /D /CA /0402P
NX-G06 /D /CA /0452P
NX-G06 /D /CA /0502P
NX-G06 /D /CA /0562P
NX-G06 /D /CA /0612P
NX-G06 /D /CA /0712P
NX-G06 /D /CA /0812P
NX-G06 /D /LN-CA /0202P
NX-G06 /D /LN-CA /0252P
NX-G06 /D /LN-CA /0262P
NX-G06 /D /LN-CA /0302P
NX-G06 /D /LN-CA /0352P
NX-G06 /D /LN-CA /0402P
NX-G06 /D /LN-CA /0452P
NX-G06 /D /LN-CA /0502P
NX-G06 /D /LN-CA /0562P
NX-G06 /D /LN-CA /0612P

ELCA_Engine ver.4.2.2.0 7.1.4 NX-G06 0202P - 0812P_201904_EN R454B


OPERATING LIMITS NX-G06 0202P - 0812P

7.2 ETHYLENE GLYCOL MIXTURE


Ethylene glycol and water mixture, used as a heat-conveying fluid, cause a variation in unit performance. For correct data, use the factors
indicated in the following tabel.
Freezing point (°C)
0 -5 -10 -15 -20 -25 -30 -35
Ethylene glycol percentage by weight
0% 12% 20% 30% 35% 40% 45% 50%
cPf 1 0,985 0,98 0,974 0,97 0,965 0,964 0,96
cQ 1 1,02 1,04 1,075 1,11 1,14 1,17 1,2
cdp 1 1,07 1,11 1,18 1,22 1,24 1,27 1,3

cPf: cooling power correction factor For data concerning other kind of anti-freeze solutions (e,g, propylene
cQ: flow correction factor glycol) please contact our Sale Department.
cdp: pressure drop correction factor

7.3 FOULING FACTORS


Performances are based on clean condition of tubes (fouling factor = 1). For different fouling values, performance should be adjusted using the
correction factors shown in the following table.
FOULING FACTORS EVAPORATOR CONDENSER/RECOVERY DESUPERHEATER
SERIES ff KE KC
F1 FK1 F2 FK2 R3
(m² °CW) [°C] [°C]
VARIOUS 0 1,000 1,000 0,0 1,000 1,000 0,0 1,000
VARIOUS 1,80 x 10 -5 1,000 1,000 0,0 1,000 1,000 0,0 1,000
VARIOUS 4,40 x 10 -5
1,000 1,000 0,0 0,990 1,030 1,0 0,990
VARIOUS 8,80 x 10 -5 0,960 0,990 0,7 0,980 1,040 1,5 0,980
VARIOUS 13,20 x 10 -5 0,944 0,985 1,0 0,964 1,050 2,3 0,964
VARIOUS 17,20 x 10 -5
0,930 0,980 1,5 0,950 1,060 3,0 0,950

ff: fouling factors


F1 - F2: potential correction factors
FK1 - FK2: compressor power input correction factors
R3: capacity correction factors
KE: minimum evaporator outlet temperature increase
KC: maximum condenser outlet temperature decrease

ELCA_Engine ver.4.2.2.0 7.1.5 NX-G06 0202P - 0812P_201904_EN R454B


8.1 HYDRAULIC DATA
[ SI System ]
Water flow and pressure drop
Water flow in the plant (side) exchanger is given by:
Q=P/(4,186 x Dt)
Q: water flow (l/s)
Dt: difference between inlet and outlet water temp. (°C)
P: heat exchanger capacity (kW)

Pressure drop is given by:


Dp= K x (3,6 x Q)^2/1000
Q: water flow (l/s)
Dp: pressure drop (kPa)
K: unit size ratio
HEAT RECOVERY EX. USER
HEAT EXCHANGER USER SIDE
Power SIDE
SIZE supply
V/ph/Hz Q min Q max C.A.S. C.a. min Q min Q max C.A.S.
K K
l/s l/s l l l/s l/s l

NX-G06 /K /0202P 400/3+N/50 454 1,444 4,444 3,30 138 - - - -


NX-G06 /K /0252P 400/3+N/50 325 1,639 4,833 3,60 156 - - - -
NX-G06 /K /0262P 400/3+N/50 265 1,806 4,833 4,05 174 - - - -
NX-G06 /K /0302P 400/3+N/50 190 2,167 4,833 4,95 213 - - - -
NX-G06 /K /0352P 400/3+N/50 233 2,472 6,111 5,77 242 - - - -
NX-G06 /K /0402P 400/3/50 162 2,861 8,667 6,56 270 - - - -
NX-G06 /K /0452P 400/3/50 132 3,222 9,750 7,36 305 - - - -
NX-G06 /K /0502P 400/3/50 102 3,611 10,86 8,48 345 - - - -
NX-G06 /K /0552P 400/3/50 84,5 4,083 10,86 9,44 401 - - - -
NX-G06 /K /0602P 400/3/50 60,6 4,694 10,86 11,5 446 - - - -
NX-G06 /K /0702P 400/3/50 46,8 5,389 11,94 13,6 503 - - - -
NX-G06 /D /K /0202P 400/3+N/50 454 1,444 4,444 3,30 138 1767 - 0,972 0,43
NX-G06 /D /K /0252P 400/3+N/50 325 1,639 4,833 3,60 156 1767 - 1,056 0,43
NX-G06 /D /K /0262P 400/3+N/50 265 1,806 4,833 4,05 174 1767 - 1,194 0,43
NX-G06 /D /K /0302P 400/3+N/50 190 2,167 4,833 4,95 213 871 - 1,444 0,61
NX-G06 /D /K /0352P 400/3+N/50 233 2,472 6,111 5,77 242 871 - 1,583 0,61
NX-G06 /D /K /0402P 400/3/50 162 2,861 8,667 6,56 270 871 - 1,833 0,61
NX-G06 /D /K /0452P 400/3/50 132 3,222 9,750 7,36 305 613 - 2,028 0,73
NX-G06 /D /K /0502P 400/3/50 102 3,611 10,86 8,48 345 613 - 2,306 0,73
NX-G06 /D /K /0552P 400/3/50 84,5 4,083 10,86 9,44 401 412 - 2,694 0,92
NX-G06 /D /K /0602P 400/3/50 60,6 4,694 10,86 11,5 446 412 - 3,194 0,92
NX-G06 /D /K /0702P 400/3/50 46,8 5,389 11,94 13,6 503 277 - 3,722 1,22
NX-G06 /LN-K /0202P 400/3+N/50 454 1,444 4,444 3,30 138 - - - -
NX-G06 /LN-K /0252P 400/3+N/50 325 1,639 4,833 3,60 156 - - - -
NX-G06 /LN-K /0262P 400/3+N/50 265 1,806 4,833 4,10 174 - - - -
NX-G06 /LN-K /0302P 400/3+N/50 190 2,167 4,833 5,00 213 - - - -
NX-G06 /LN-K /0352P 400/3/50 233 2,472 6,111 5,80 242 - - - -
NX-G06 /LN-K /0402P 400/3/50 162 2,861 8,667 6,60 270 - - - -
NX-G06 /LN-K /0452P 400/3/50 132 3,222 9,750 7,40 305 - - - -
NX-G06 /LN-K /0502P 400/3/50 102 3,611 10,86 8,50 345 - - - -
NX-G06 /LN-K /0552P 400/3/50 84,5 4,083 10,86 9,40 401 - - - -
NX-G06 /LN-K /0602P 400/3/50 60,6 4,694 10,86 11,5 446 - - - -
NX-G06 /LN-K /0702P 400/3/50 46,8 5,389 11,94 13,6 503 - - - -
NX-G06 /D /LN-K /0202P 400/3+N/50 454 1,444 4,444 3,30 138 1767 - 0,972 0,43
NX-G06 /D /LN-K /0252P 400/3+N/50 325 1,639 4,833 3,60 156 1767 - 1,056 0,43
NX-G06 /D /LN-K /0262P 400/3+N/50 265 1,806 4,833 4,10 174 1767 - 1,194 0,43
NX-G06 /D /LN-K /0302P 400/3+N/50 190 2,167 4,833 5,00 213 871 - 1,444 0,61
NX-G06 /D /LN-K /0352P 400/3/50 233 2,472 6,111 5,80 242 871 - 1,583 0,61
NX-G06 /D /LN-K /0402P 400/3/50 162 2,861 8,667 6,60 270 871 - 1,833 0,61
NX-G06 /D /LN-K /0452P 400/3/50 132 3,222 9,750 7,40 305 613 - 2,028 0,73
NX-G06 /D /LN-K /0502P 400/3/50 102 3,611 10,86 8,50 345 613 - 2,306 0,73

Q min: minimum water flow admitted to the heat exchanger


Q max: maximum water flow admitted to the heat exchanger
C.a. min: minimum water content admitted in the plant
C.A.S.: Exchanger water content

ELCA_Engine ver.4.2.2.0 8.1.1 NX-G06 0202P - 0812P_201904_EN R454B


HYDRAULIC DATA
[ SI System ]

HEAT RECOVERY EX. USER


HEAT EXCHANGER USER SIDE
Power SIDE
SIZE supply
V/ph/Hz Q min Q max C.A.S. C.a. min Q min Q max C.A.S.
K K
l/s l/s l l l/s l/s l

NX-G06 /D /LN-K /0552P 400/3/50 84,5 4,083 10,86 9,40 401 412 - 2,694 0,92
NX-G06 /D /LN-K /0602P 400/3/50 60,6 4,694 10,86 11,5 446 412 - 3,194 0,92
NX-G06 /D /LN-K /0702P 400/3/50 46,8 5,389 11,94 13,6 503 277 - 3,722 1,22
NX-G06 /SL-K /0202P 400/3+N/50 454 1,444 4,444 3,30 138 - - - -
NX-G06 /SL-K /0252P 400/3/50 325 1,639 4,833 3,60 156 - - - -
NX-G06 /SL-K /0262P 400/3/50 265 1,806 4,833 4,10 174 - - - -
NX-G06 /SL-K /0302P 400/3/50 190 2,167 4,833 5,00 213 - - - -
NX-G06 /SL-K /0352P 400/3/50 233 2,472 6,111 5,80 242 - - - -
NX-G06 /SL-K /0402P 400/3/50 162 2,861 8,667 6,60 270 - - - -
NX-G06 /SL-K /0452P 400/3/50 132 3,222 9,750 7,40 305 - - - -
NX-G06 /SL-K /0502P 400/3/50 102 3,611 10,86 8,50 345 - - - -
NX-G06 /SL-K /0552P 400/3/50 84,5 4,083 10,86 9,40 401 - - - -
NX-G06 /SL-K /0602P 400/3/50 60,6 4,694 10,86 11,5 446 - - - -
NX-G06 /D /SL-K /0202P 400/3+N/50 454 1,444 4,444 3,30 138 1767 - 0,972 0,43
NX-G06 /D /SL-K /0252P 400/3/50 325 1,639 4,833 3,60 156 1767 - 1,056 0,43
NX-G06 /D /SL-K /0262P 400/3/50 265 1,806 4,833 4,10 174 1767 - 1,194 0,43
NX-G06 /D /SL-K /0302P 400/3/50 190 2,167 4,833 5,00 213 871 - 1,444 0,61
NX-G06 /D /SL-K /0352P 400/3/50 233 2,472 6,111 5,80 242 871 - 1,583 0,61
NX-G06 /D /SL-K /0402P 400/3/50 162 2,861 8,667 6,60 270 871 - 1,833 0,61
NX-G06 /D /SL-K /0452P 400/3/50 132 3,222 9,750 7,40 305 613 - 2,028 0,73
NX-G06 /D /SL-K /0502P 400/3/50 102 3,611 10,86 8,50 345 613 - 2,306 0,73
NX-G06 /D /SL-K /0552P 400/3/50 84,5 4,083 10,86 9,40 401 412 - 2,694 0,92
NX-G06 /D /SL-K /0602P 400/3/50 60,6 4,694 10,86 11,5 446 412 - 3,194 0,92
NX-G06 /CA /0202P 400/3+N/50 454 1,444 4,444 3,30 138 - - - -
NX-G06 /CA /0252P 400/3+N/50 325 1,639 4,833 3,60 156 - - - -
NX-G06 /CA /0262P 400/3+N/50 265 1,806 4,833 4,10 174 - - - -
NX-G06 /CA /0302P 400/3/50 190 2,167 4,833 5,00 213 - - - -
NX-G06 /CA /0352P 400/3/50 233 2,472 6,111 5,80 242 - - - -
NX-G06 /CA /0402P 400/3/50 162 2,861 8,667 6,60 270 - - - -
NX-G06 /CA /0452P 400/3/50 132 3,222 9,750 7,40 305 - - - -
NX-G06 /CA /0502P 400/3/50 102 3,611 10,86 8,50 345 - - - -
NX-G06 /CA /0562P 400/3/50 84,5 4,083 10,86 9,40 401 - - - -
NX-G06 /CA /0612P 400/3/50 60,6 4,694 10,86 11,5 446 - - - -
NX-G06 /CA /0712P 400/3/50 46,8 5,389 11,94 13,6 503 - - - -
NX-G06 /CA /0812P 400/3/50 46,8 5,861 11,94 13,6 568 - - - -
NX-G06 /D /CA /0202P 400/3+N/50 454 1,444 4,444 3,30 138 1767 - 0,972 0,43
NX-G06 /D /CA /0252P 400/3+N/50 325 1,639 4,833 3,60 156 1767 - 1,056 0,43
NX-G06 /D /CA /0262P 400/3+N/50 265 1,806 4,833 4,10 174 1767 - 1,194 0,43
NX-G06 /D /CA /0302P 400/3/50 190 2,167 4,833 5,00 213 871 - 1,444 0,61
NX-G06 /D /CA /0352P 400/3/50 233 2,472 6,111 5,80 242 871 - 1,583 0,61
NX-G06 /D /CA /0402P 400/3/50 162 2,861 8,667 6,60 270 871 - 1,833 0,61
NX-G06 /D /CA /0452P 400/3/50 132 3,222 9,750 7,40 305 613 - 2,028 0,73
NX-G06 /D /CA /0502P 400/3/50 102 3,611 10,86 8,50 345 613 - 2,306 0,73
NX-G06 /D /CA /0562P 400/3/50 84,5 4,083 10,86 9,40 401 412 - 2,694 0,92
NX-G06 /D /CA /0612P 400/3/50 60,6 4,694 10,86 11,5 446 412 - 3,194 0,92
NX-G06 /D /CA /0712P 400/3/50 46,8 5,389 11,94 13,6 503 277 - 3,722 1,22
NX-G06 /D /CA /0812P 400/3/50 46,8 5,861 11,94 13,6 568 277 - 4,361 1,22
NX-G06 /LN-CA /0202P 400/3+N/50 454 1,444 4,444 3,30 138 - - - -
NX-G06 /LN-CA /0252P 400/3/50 325 1,639 4,833 3,60 156 - - - -

Q min: minimum water flow admitted to the heat exchanger


Q max: maximum water flow admitted to the heat exchanger
C.a. min: minimum water content admitted in the plant
C.A.S.: Exchanger water content

ELCA_Engine ver.4.2.2.0 8.1.2 NX-G06 0202P - 0812P_201904_EN R454B


HYDRAULIC DATA
[ SI System ]

HEAT RECOVERY EX. USER


HEAT EXCHANGER USER SIDE
Power SIDE
SIZE supply
V/ph/Hz Q min Q max C.A.S. C.a. min Q min Q max C.A.S.
K K
l/s l/s l l l/s l/s l

NX-G06 /LN-CA /0262P 400/3/50 265 1,806 4,833 4,10 174 - - - -


NX-G06 /LN-CA /0302P 400/3/50 190 2,167 4,833 5,00 213 - - - -
NX-G06 /LN-CA /0352P 400/3/50 233 2,472 6,111 5,80 242 - - - -
NX-G06 /LN-CA /0402P 400/3/50 162 2,861 8,667 6,60 270 - - - -
NX-G06 /LN-CA /0452P 400/3/50 132 3,222 9,750 7,40 305 - - - -
NX-G06 /LN-CA /0502P 400/3/50 102 3,611 10,86 8,50 345 - - - -
NX-G06 /LN-CA /0562P 400/3/50 84,5 4,083 10,86 9,40 401 - - - -
NX-G06 /LN-CA /0612P 400/3/50 60,6 4,694 10,86 11,5 446 - - - -
NX-G06 /LN-CA /0712P 400/3/50 46,8 5,389 11,94 13,6 503 - - - -
NX-G06 /LN-CA /0812P 400/3/50 46,8 5,861 11,94 13,6 568 - - - -
NX-G06 /D /LN-CA /0202P 400/3+N/50 454 1,444 4,444 3,30 138 1767 - 0,972 0,43
NX-G06 /D /LN-CA /0252P 400/3/50 325 1,639 4,833 3,60 156 1767 - 1,056 0,43
NX-G06 /D /LN-CA /0262P 400/3/50 265 1,806 4,833 4,10 174 1767 - 1,194 0,43
NX-G06 /D /LN-CA /0302P 400/3/50 190 2,167 4,833 5,00 213 871 - 1,444 0,61
NX-G06 /D /LN-CA /0352P 400/3/50 233 2,472 6,111 5,80 242 871 - 1,583 0,61
NX-G06 /D /LN-CA /0402P 400/3/50 162 2,861 8,667 6,60 270 871 - 1,833 0,61
NX-G06 /D /LN-CA /0452P 400/3/50 132 3,222 9,750 7,40 305 613 - 2,028 0,73
NX-G06 /D /LN-CA /0502P 400/3/50 102 3,611 10,86 8,50 345 613 - 2,306 0,73
NX-G06 /D /LN-CA /0562P 400/3/50 84,5 4,083 10,86 9,40 401 412 - 2,694 0,92
NX-G06 /D /LN-CA /0612P 400/3/50 60,6 4,694 10,86 11,5 446 412 - 3,194 0,92
NX-G06 /D /LN-CA /0712P 400/3/50 46,8 5,389 11,94 13,6 503 277 - 3,722 1,22
NX-G06 /D /LN-CA /0812P 400/3/50 46,8 5,861 11,94 13,6 568 277 - 4,361 1,22
NX-G06 /SL-CA /0202P 400/3/50 454 1,444 4,444 3,30 138 - - - -
NX-G06 /SL-CA /0252P 400/3/50 325 1,639 4,833 3,60 156 - - - -
NX-G06 /SL-CA /0262P 400/3/50 265 1,806 4,833 4,10 174 - - - -
NX-G06 /SL-CA /0302P 400/3/50 190 2,167 4,833 5,00 213 - - - -
NX-G06 /SL-CA /0352P 400/3/50 233 2,472 6,111 5,80 242 - - - -
NX-G06 /SL-CA /0412P 400/3/50 162 2,861 8,667 6,60 270 - - - -
NX-G06 /SL-CA /0462P 400/3/50 132 3,222 9,750 7,40 305 - - - -
NX-G06 /SL-CA /0512P 400/3/50 102 3,611 10,86 8,50 345 - - - -
NX-G06 /SL-CA /0562P 400/3/50 84,5 4,083 10,86 9,40 401 - - - -
NX-G06 /SL-CA /0612P 400/3/50 60,6 4,694 10,86 11,5 446 - - - -
NX-G06 /SL-CA /0712P 400/3/50 46,8 5,389 11,94 13,6 503 - - - -
NX-G06 /SL-CA /0812P 400/3/50 46,8 5,861 11,94 13,6 568 - - - -
NX-G06 /D /SL-CA /0202P 400/3/50 454 1,444 4,444 3,30 138 1767 - 0,972 0,43
NX-G06 /D /SL-CA /0252P 400/3/50 325 1,639 4,833 3,60 156 1767 - 1,056 0,43
NX-G06 /D /SL-CA /0262P 400/3/50 265 1,806 4,833 4,10 174 1767 - 1,194 0,43
NX-G06 /D /SL-CA /0302P 400/3/50 190 2,167 4,833 5,00 213 871 - 1,444 0,61
NX-G06 /D /SL-CA /0352P 400/3/50 233 2,472 6,111 5,80 242 871 - 1,583 0,61
NX-G06 /D /SL-CA /0412P 400/3/50 162 2,861 8,667 6,60 270 871 - 1,833 0,61
NX-G06 /D /SL-CA /0462P 400/3/50 132 3,222 9,750 7,40 305 613 - 2,028 0,73
NX-G06 /D /SL-CA /0512P 400/3/50 102 3,611 10,86 8,50 345 613 - 2,306 0,73
NX-G06 /D /SL-CA /0562P 400/3/50 84,5 4,083 10,86 9,40 401 412 - 2,694 0,92
NX-G06 /D /SL-CA /0612P 400/3/50 60,6 4,694 10,86 11,5 446 412 - 3,194 0,92
NX-G06 /D /SL-CA /0712P 400/3/50 46,8 5,389 11,94 13,6 503 277 - 3,722 1,22
NX-G06 /D /SL-CA /0812P 400/3/50 46,8 5,861 11,94 13,6 568 277 - 4,361 1,22

Q min: minimum water flow admitted to the heat exchanger


Q max: maximum water flow admitted to the heat exchanger
C.a. min: minimum water content admitted in the plant
C.A.S.: Exchanger water content

ELCA_Engine ver.4.2.2.0 8.1.3 NX-G06 0202P - 0812P_201904_EN R454B


9.1 ELECTRICAL DATA NX-G06/K
[ SI System ]

Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202P 400/3+N/50 2 2 x 10.5 2 x 16.6 2 x 123 0,250 1 22,00 38 144
0252P 400/3+N/50 2 2 x 11.5 2 x 18.3 2 x 138 0,250 1 24,00 41 161
0262P 400/3+N/50 2 2 x 13.1 2 x 20.8 2 x 145 0,250 1 27,20 46 170
0302P 400/3+N/50 2 2 x 15.4 2 x 24.9 2 x 172 0,250 1 32,20 56 204
0352P 400/3+N/50 2 1x15.4 + 1x21.4 1x24.9 + 1x34.2 1x172 + 1x211 0,250 1 38,30 66 243
0402P 400/3/50 2 2 x 21.4 2 x 34.2 2 x 211 2,000 4 46,80 76 253
0452P 400/3/50 2 1x21.4 + 1x27 1x34.2 + 1x42.5 1x211 + 1x210 2,000 4 52,40 85 253
0502P 400/3/50 2 2 x 27 2 x 42.5 2 x 210 2,000 4 58,00 93 260
0552P 400/3/50 2 1x27 + 1x34.5 1x42.5 + 1x55.1 1x210 + 1x326 2,000 4 65,50 105 376
0602P 400/3/50 2 2 x 34.5 2 x 55.1 2 x 326 2,000 4 75,00 122 393
0702P 400/3/50 2 2 x 37.8 2 x 62.3 2 x 326 2,000 4 81,60 136 400

F.L.I.: Full load power


F.L.A.: Full load current
L.R.A.: Locked rotor amperes for single compressor
S.A.: Inrush current

(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections

Data valid for standard units without any additional option.

Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.

Voltage tolerance: 10%


Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

ELCA_Engine ver.4.2.2.0 9.1.1 NX-G06 0202P - 0812P_201904_EN R454B


ELECTRICAL DATA NX-G06/LN-K
[ SI System ]

Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202P 400/3+N/50 2 2 x 10.5 2 x 16.6 2 x 123 0,250 1 22,00 38 144
0252P 400/3+N/50 2 2 x 11.5 2 x 18.3 2 x 138 0,160 1 23,90 41 160
0262P 400/3+N/50 2 2 x 13.1 2 x 20.8 2 x 145 0,160 1 27,10 45 170
0302P 400/3+N/50 2 2 x 15.4 2 x 24.9 2 x 172 0,160 1 31,70 54 201
0352P 400/3/50 2 1x15.4 + 1x21.4 1x24.9 + 1x34.2 1x172 + 1x211 2,000 4 40,80 67 244
0402P 400/3/50 2 2 x 21.4 2 x 34.2 2 x 211 2,000 4 46,80 76 253
0452P 400/3/50 2 1x21.4 + 1x27 1x34.2 + 1x42.5 1x211 + 1x210 1,840 4 52,10 84 253
0502P 400/3/50 2 2 x 27 2 x 42.5 2 x 210 1,840 4 57,70 93 260
0552P 400/3/50 2 1x27 + 1x34.5 1x42.5 + 1x55.1 1x210 + 1x326 1,840 4 65,20 105 376
0602P 400/3/50 2 2 x 34.5 2 x 55.1 2 x 326 2,000 4 75,00 122 393
0702P 400/3/50 2 2 x 37.8 2 x 62.3 2 x 326 2,000 4 81,60 136 400

F.L.I.: Full load power


F.L.A.: Full load current
L.R.A.: Locked rotor amperes for single compressor
S.A.: Inrush current

(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections

Data valid for standard units without any additional option.

Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.

Voltage tolerance: 10%


Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

ELCA_Engine ver.4.2.2.0 9.1.2 NX-G06 0202P - 0812P_201904_EN R454B


ELECTRICAL DATA NX-G06/SL-K
[ SI System ]

Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202P 400/3+N/50 2 2 x 10.5 2 x 16.6 2 x 123 0,160 1 22,00 37 143
0252P 400/3/50 2 2 x 11.5 2 x 18.3 2 x 138 1,200 4 25,40 44 164
0262P 400/3/50 2 2 x 13.1 2 x 20.8 2 x 145 1,200 4 28,60 49 174
0302P 400/3/50 2 2 x 15.4 2 x 24.9 2 x 172 1,200 4 33,10 58 205
0352P 400/3/50 2 1x15.4 + 1x21.4 1x24.9 + 1x34.2 1x172 + 1x211 1,150 2 39,10 64 240
0402P 400/3/50 2 2 x 21.4 2 x 34.2 2 x 211 1,150 2 45,10 73 250
0452P 400/3/50 2 1x21.4 + 1x27 1x34.2 + 1x42.5 1x211 + 1x210 1,200 4 50,80 85 253
0502P 400/3/50 2 2 x 27 2 x 42.5 2 x 210 1,200 4 57,60 97 264
0552P 400/3/50 2 1x27 + 1x34.5 1x42.5 + 1x55.1 1x210 + 1x326 1,200 4 65,10 109 380
0602P 400/3/50 2 2 x 34.5 2 x 55.1 2 x 326 1,200 4 72,60 122 393

F.L.I.: Full load power


F.L.A.: Full load current
L.R.A.: Locked rotor amperes for single compressor
S.A.: Inrush current

(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections

Data valid for standard units without any additional option.

Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.

Voltage tolerance: 10%


Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

ELCA_Engine ver.4.2.2.0 9.1.3 NX-G06 0202P - 0812P_201904_EN R454B


ELECTRICAL DATA NX-G06/CA
[ SI System ]

Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202P 400/3+N/50 2 2 x 10.5 2 x 16.6 2 x 123 0,250 1 22,50 40 146
0252P 400/3+N/50 2 2 x 11.5 2 x 18.3 2 x 138 0,250 1 24,50 43 163
0262P 400/3+N/50 2 2 x 13.1 2 x 20.8 2 x 145 0,250 1 27,70 48 172
0302P 400/3/50 2 2 x 15.4 2 x 24.9 2 x 172 2,000 4 34,70 58 205
0352P 400/3/50 2 1x15.4 + 1x21.4 1x24.9 + 1x34.2 1x172 + 1x211 2,000 4 40,80 67 244
0402P 400/3/50 2 2 x 21.4 2 x 34.2 2 x 211 1,840 4 46,50 76 253
0452P 400/3/50 2 1x21.4 + 1x27 1x34.2 + 1x42.5 1x211 + 1x210 1,840 4 52,10 84 253
0502P 400/3/50 2 2 x 27 2 x 42.5 2 x 210 2,000 4 60,00 97 264
0562P 400/3/50 2 1x27 + 1x34.5 1x42.5 + 1x55.1 1x210 + 1x326 2,000 4 69,50 114 385
0612P 400/3/50 2 2 x 34.5 2 x 55.1 2 x 326 2,000 4 77,00 127 398
0712P 400/3/50 2 2 x 37.8 2 x 62.3 2 x 326 2,000 4 84,50 140 398
0812P 400/3/50 2 2 x 42 2 x 68.4 2 x 298 2,000 4 94,00 157 387

F.L.I.: Full load power


F.L.A.: Full load current
L.R.A.: Locked rotor amperes for single compressor
S.A.: Inrush current

(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections

Data valid for standard units without any additional option.

Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.

Voltage tolerance: 10%


Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

ELCA_Engine ver.4.2.2.0 9.1.4 NX-G06 0202P - 0812P_201904_EN R454B


ELECTRICAL DATA NX-G06/LN-CA
[ SI System ]

Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202P 400/3+N/50 2 2 x 10.5 2 x 16.6 2 x 123 0,160 1 22,00 37 143
0252P 400/3/50 2 2 x 11.5 2 x 18.3 2 x 138 2,000 4 27,00 44 164
0262P 400/3/50 2 2 x 13.1 2 x 20.8 2 x 145 2,000 4 30,20 49 174
0302P 400/3/50 2 2 x 15.4 2 x 24.9 2 x 172 2,000 4 34,70 58 205
0352P 400/3/50 2 1x15.4 + 1x21.4 1x24.9 + 1x34.2 1x172 + 1x211 1,840 4 40,40 67 243
0402P 400/3/50 2 2 x 21.4 2 x 34.2 2 x 211 2,000 4 48,80 80 257
0452P 400/3/50 2 1x21.4 + 1x27 1x34.2 + 1x42.5 1x211 + 1x210 2,000 4 52,40 85 253
0502P 400/3/50 2 2 x 27 2 x 42.5 2 x 210 2,000 4 60,00 97 264
0562P 400/3/50 2 1x27 + 1x34.5 1x42.5 + 1x55.1 1x210 + 1x326 0,930 2 65,20 107 378
0612P 400/3/50 2 2 x 34.5 2 x 55.1 2 x 326 0,930 2 72,70 119 390
0712P 400/3/50 2 2 x 37.8 2 x 62.3 2 x 326 0,930 2 81,20 135 393
0812P 400/3/50 2 2 x 42 2 x 68.4 2 x 298 0,930 2 89,60 151 380

F.L.I.: Full load power


F.L.A.: Full load current
L.R.A.: Locked rotor amperes for single compressor
S.A.: Inrush current

(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections

Data valid for standard units without any additional option.

Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.

Voltage tolerance: 10%


Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

ELCA_Engine ver.4.2.2.0 9.1.5 NX-G06 0202P - 0812P_201904_EN R454B


ELECTRICAL DATA NX-G06/SL-CA
[ SI System ]

Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202P 400/3/50 2 2 x 10.5 2 x 16.6 2 x 123 1,200 4 23,40 41 147
0252P 400/3/50 2 2 x 11.5 2 x 18.3 2 x 138 1,150 2 25,30 41 161
0262P 400/3/50 2 2 x 13.1 2 x 20.8 2 x 145 1,150 2 28,50 46 170
0302P 400/3/50 2 2 x 15.4 2 x 24.9 2 x 172 1,150 2 33,00 54 201
0352P 400/3/50 2 1x15.4 + 1x21.4 1x24.9 + 1x34.2 1x172 + 1x211 1,200 4 40,40 71 248
0412P 400/3/50 2 2 x 21.4 2 x 34.2 2 x 211 0,930 2 46,50 78 254
0462P 400/3/50 2 1x21.4 + 1x27 1x34.2 + 1x42.5 1x211 + 1x210 0,930 2 52,10 86 254
0512P 400/3/50 2 2 x 27 2 x 42.5 2 x 210 0,930 2 57,70 94 262
0562P 400/3/50 2 1x27 + 1x34.5 1x42.5 + 1x55.1 1x210 + 1x326 0,930 2 66,20 109 380
0612P 400/3/50 2 2 x 34.5 2 x 55.1 2 x 326 0,930 2 74,60 124 395
0712P 400/3/50 2 2 x 37.8 2 x 62.3 2 x 326 0,930 2 82,10 137 395
0812P 400/3/50 2 2 x 42 2 x 68.4 2 x 298 0,930 2 90,50 153 383

F.L.I.: Full load power


F.L.A.: Full load current
L.R.A.: Locked rotor amperes for single compressor
S.A.: Inrush current

(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections

Data valid for standard units without any additional option.

Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.

Voltage tolerance: 10%


Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

ELCA_Engine ver.4.2.2.0 9.1.6 NX-G06 0202P - 0812P_201904_EN R454B


10.1 FULL LOAD SOUND LEVEL NX-G06/K

SOUND POWER LEVEL IN COOLING


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202P 85 85 81 80 80 77 69 57 84
0252P 85 85 81 80 80 77 69 57 84
0262P 85 85 81 80 80 77 69 57 84
0302P 86 86 82 81 81 78 70 58 85
0352P 87 87 83 82 82 79 71 59 86
0402P 89 89 85 84 84 81 73 61 88
0452P 89 89 85 84 84 81 73 61 88
0502P 89 89 85 84 84 81 73 61 88
0552P 90 90 86 85 85 82 74 62 89
0602P 91 91 87 86 86 83 75 63 90
0702P 91 91 87 86 86 83 75 63 90

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.

SOUND PRESSURE LEVEL


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound pressure level dB
0202P 53 53 49 48 48 45 37 25 52
0252P 53 53 49 48 48 45 37 25 52
0262P 53 53 49 48 48 45 37 25 52
0302P 54 54 50 49 49 46 38 26 53
0352P 55 55 51 50 50 47 39 27 54
0402P 57 57 53 52 52 49 41 29 56
0452P 57 57 53 52 52 49 41 29 56
0502P 57 57 53 52 52 49 41 29 56
0552P 58 58 54 53 53 50 42 30 57
0602P 59 59 55 54 54 51 43 31 58
0702P 59 59 55 54 54 51 43 31 58

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.

ELCA_Engine ver.4.2.2.0 10.1.1 NX-G06 0202P - 0812P_201904_EN R454B


FULL LOAD SOUND LEVEL NX-G06/LN-K

SOUND POWER LEVEL IN COOLING


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202P 80 80 77 76 75 71 65 50 79
0252P 81 81 78 77 76 72 66 51 80
0262P 81 81 78 77 76 72 66 51 80
0302P 81 81 78 77 76 72 66 51 80
0352P 85 83 84 83 77 72 66 60 83
0402P 85 83 84 83 77 72 66 60 83
0452P 86 84 85 84 78 73 67 61 84
0502P 86 84 85 84 78 73 67 61 84
0552P 86 84 85 84 78 73 67 61 84
0602P 87 85 86 85 79 74 68 62 85
0702P 87 85 86 85 79 74 68 62 85

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.

SOUND PRESSURE LEVEL


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound pressure level dB
0202P 48 48 45 44 43 39 33 18 47
0252P 49 49 46 45 44 40 34 19 48
0262P 49 49 46 45 44 40 34 19 48
0302P 49 49 46 45 44 40 34 19 48
0352P 53 51 52 51 45 40 34 28 51
0402P 53 51 52 51 45 40 34 28 51
0452P 54 52 53 52 46 41 35 29 52
0502P 54 52 53 52 46 41 35 29 52
0552P 54 52 53 52 46 41 35 29 52
0602P 55 53 54 53 47 42 36 30 53
0702P 55 53 54 53 47 42 36 30 53

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.

ELCA_Engine ver.4.2.2.0 10.1.2 NX-G06 0202P - 0812P_201904_EN R454B


FULL LOAD SOUND LEVEL NX-G06/SL-K

SOUND POWER LEVEL IN COOLING


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202P 82 80 78 75 72 67 61 57 77
0252P 83 81 79 76 73 68 62 58 78
0262P 83 81 79 76 73 68 62 58 78
0302P 83 81 79 76 73 68 62 58 78
0352P 84 82 80 77 74 69 63 59 79
0402P 85 83 81 78 75 70 64 60 80
0452P 85 84 82 79 76 71 65 61 81
0502P 85 84 82 79 76 71 65 61 81
0552P 87 85 83 81 76 72 66 62 82
0602P 87 85 83 81 76 72 66 62 82

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.

SOUND PRESSURE LEVEL


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound pressure level dB
0202P 50 48 46 43 40 35 29 25 45
0252P 51 49 47 44 41 36 30 26 46
0262P 51 49 47 44 41 36 30 26 46
0302P 51 49 47 44 41 36 30 26 46
0352P 52 50 48 45 42 37 31 27 47
0402P 53 51 49 46 43 38 32 28 48
0452P 53 52 50 47 44 39 33 29 49
0502P 53 52 50 47 44 39 33 29 49
0552P 55 53 51 49 44 40 34 30 50
0602P 55 53 51 49 44 40 34 30 50

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.

ELCA_Engine ver.4.2.2.0 10.1.3 NX-G06 0202P - 0812P_201904_EN R454B


FULL LOAD SOUND LEVEL NX-G06/CA

SOUND POWER LEVEL IN COOLING


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202P 86 86 82 81 81 78 70 58 85
0252P 86 86 82 81 81 78 70 58 85
0262P 87 87 83 82 82 79 71 59 86
0302P 89 89 85 84 84 81 73 61 88
0352P 89 89 85 84 84 81 73 61 88
0402P 91 91 87 86 86 83 75 63 90
0452P 91 91 87 86 86 83 75 63 90
0502P 91 91 87 86 86 83 75 63 90
0562P 92 92 88 87 87 84 76 64 91
0612P 92 92 88 87 87 84 76 64 91
0712P 93 93 89 88 88 85 77 65 92
0812P 94 94 90 89 89 86 78 66 93

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.

SOUND PRESSURE LEVEL


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound pressure level dB
0202P 54 54 50 49 49 46 38 26 53
0252P 54 54 50 49 49 46 38 26 53
0262P 55 55 51 50 50 47 39 27 54
0302P 57 57 53 52 52 49 41 29 56
0352P 57 57 53 52 52 49 41 29 56
0402P 59 59 55 54 54 51 43 31 58
0452P 59 59 55 54 54 51 43 31 58
0502P 59 59 55 54 54 51 43 31 58
0562P 60 60 56 55 55 52 44 32 59
0612P 60 60 56 55 55 52 44 32 59
0712P 61 61 57 56 56 53 45 33 60
0812P 62 62 58 57 57 54 46 34 61

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.

ELCA_Engine ver.4.2.2.0 10.1.4 NX-G06 0202P - 0812P_201904_EN R454B


FULL LOAD SOUND LEVEL NX-G06/LN-CA

SOUND POWER LEVEL IN COOLING


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202P 81 81 78 77 76 72 66 51 80
0252P 83 81 82 81 75 70 64 58 81
0262P 83 81 82 81 75 70 64 58 81
0302P 84 82 83 82 76 71 65 59 82
0352P 86 84 85 84 78 73 67 61 84
0402P 86 84 85 84 78 73 67 61 84
0452P 86 84 85 84 78 73 67 61 84
0502P 87 85 86 85 79 74 68 62 85
0562P 88 86 87 86 80 75 69 63 86
0612P 88 86 87 86 80 75 69 63 86
0712P 89 87 88 87 81 76 70 64 87
0812P 90 88 89 88 82 77 71 65 88

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.

SOUND PRESSURE LEVEL


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound pressure level dB
0202P 49 49 46 45 44 40 34 19 48
0252P 51 49 50 49 43 38 32 26 49
0262P 51 49 50 49 43 38 32 26 49
0302P 52 50 51 50 44 39 33 27 50
0352P 54 52 53 52 46 41 35 29 52
0402P 54 52 53 52 46 41 35 29 52
0452P 54 52 53 52 46 41 35 29 52
0502P 55 53 54 53 47 42 36 30 53
0562P 56 54 55 54 48 43 37 31 54
0612P 56 54 55 54 48 43 37 31 54
0712P 57 55 56 55 49 44 38 32 55
0812P 58 56 57 56 50 45 39 33 56

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.

ELCA_Engine ver.4.2.2.0 10.1.5 NX-G06 0202P - 0812P_201904_EN R454B


FULL LOAD SOUND LEVEL NX-G06/SL-CA

SOUND POWER LEVEL IN COOLING


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202P 83 81 79 76 73 68 62 58 78
0252P 84 82 80 77 74 69 63 59 79
0262P 84 82 80 77 74 69 63 59 79
0302P 84 82 80 77 74 69 63 59 79
0352P 85 83 81 78 75 70 64 60 80
0412P 85 84 82 79 76 71 65 61 81
0462P 87 85 83 81 76 72 66 62 82
0512P 87 85 83 81 76 72 66 62 82
0562P 88 86 84 82 76 73 67 63 83
0612P 89 87 85 83 77 74 68 64 84
0712P 89 88 86 84 79 74 68 64 85
0812P 89 89 87 85 80 75 69 64 86

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.

SOUND PRESSURE LEVEL


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound pressure level dB
0202P 51 49 47 44 41 36 30 26 46
0252P 52 50 48 45 42 37 31 27 47
0262P 52 50 48 45 42 37 31 27 47
0302P 52 50 48 45 42 37 31 27 47
0352P 53 51 49 46 43 38 32 28 48
0412P 53 52 50 47 44 39 33 29 49
0462P 55 53 51 49 44 40 34 30 50
0512P 55 53 51 49 44 40 34 30 50
0562P 56 54 52 50 44 41 35 31 51
0612P 57 55 53 51 45 42 36 32 52
0712P 57 56 54 52 47 42 36 32 53
0812P 57 57 55 53 48 43 37 32 54

Working conditions
Plant (side) cooling exchanger water (in/out) 12,00°C/7,00°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.

ELCA_Engine ver.4.2.2.0 10.1.6 NX-G06 0202P - 0812P_201904_EN R454B


ELCA_Engine ver.4.2.2.0
11.1 DIMENSIONAL DRAWINGS

11.1.1
NX-G06 0202P - 0812P

NX-G06 0202P - 0812P_201904_EN


REMARKS:For installation purposes, please refer to the documentation sent after the purchase-contract. This technical data should be considered as indicative. Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A. may modify them at any moment. Data valid for
standard units without any additional option.

R454B
DIMENSIONAL DRAWINGS NX-G06 0202P - 0812P
[ SI System ]

DIMENSIONS AND HEAT EXCHANGER HEAT RECOVERY EX.


CLEARANCE
WEIGHTS USER SIDE USER SIDE
SIZE
A B H WEIGHT R1 R2 R3 R4 IN/OUT IN/OUT
[mm] [mm] [mm] [kg] [mm] [mm] [mm] [mm] TYPE Ø TYPE Ø
NX-G06 /K /0202P 1825 1195 1865 520 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /K /0252P 2395 1195 1865 570 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /K /0262P 2395 1195 1865 580 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /K /0302P 2395 1195 1865 600 1000 1000 1000 1000 F 2" - -
NX-G06 /K /0352P 2395 1195 1865 610 1000 1000 1000 1000 F 2" - -
NX-G06 /K /0402P 2825 1195 1980 700 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /K /0452P 2825 1195 1980 790 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /K /0502P 2825 1195 1980 860 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /K /0552P 3360 1195 1980 930 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /K /0602P 3980 1195 1980 1060 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /K /0702P 3980 1195 1980 1080 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /D /K /0202P 1825 1195 1865 520 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /K /0252P 2395 1195 1865 570 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /K /0262P 2395 1195 1865 580 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /K /0302P 2395 1195 1865 600 1000 1000 1000 1000 F 2" B 1" 1/4
NX-G06 /D /K /0352P 2395 1195 1865 610 1000 1000 1000 1000 F 2" B 1" 1/4
NX-G06 /D /K /0402P 2825 1195 1980 700 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /K /0452P 2825 1195 1980 790 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /K /0502P 2825 1195 1980 860 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /K /0552P 3360 1195 1980 930 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /K /0602P 3980 1195 1980 1060 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /K /0702P 3980 1195 1980 1080 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /LN-K /0202P 2395 1195 1865 570 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /LN-K /0252P 2395 1195 1865 600 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /LN-K /0262P 2395 1195 1865 600 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /LN-K /0302P 2395 1195 1865 610 1000 1000 1000 1000 F 2" - -
NX-G06 /LN-K /0352P 2825 1195 1980 730 1000 1000 1000 1000 F 2" - -
NX-G06 /LN-K /0402P 2825 1195 1980 750 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /LN-K /0452P 3360 1195 1980 920 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /LN-K /0502P 3360 1195 1980 990 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /LN-K /0552P 3360 1195 1980 1010 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /LN-K /0602P 3980 1195 1980 1110 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /LN-K /0702P 3980 1195 1980 1120 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /D /LN-K /0202P 2395 1195 1865 570 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /LN-K /0252P 2395 1195 1865 600 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /LN-K /0262P 2395 1195 1865 600 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /LN-K /0302P 2395 1195 1865 610 1000 1000 1000 1000 F 2" B 1" 1/4
NX-G06 /D /LN-K /0352P 2825 1195 1980 730 1000 1000 1000 1000 F 2" B 1" 1/4
NX-G06 /D /LN-K /0402P 2825 1195 1980 750 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /LN-K /0452P 3360 1195 1980 920 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /LN-K /0502P 3360 1195 1980 990 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /LN-K /0552P 3360 1195 1980 1010 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /LN-K /0602P 3980 1195 1980 1110 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /LN-K /0702P 3980 1195 1980 1120 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /SL-K /0202P 2395 1195 1865 590 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /SL-K /0252P 2825 1195 1980 700 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /SL-K /0262P 2825 1195 1980 710 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /SL-K /0302P 2825 1195 1980 710 1000 1000 1000 1000 F 2" - -
NX-G06 /SL-K /0352P 3360 1195 1980 810 1000 1000 1000 1000 F 2" - -
NX-G06 /SL-K /0402P 3360 1195 1980 830 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /SL-K /0452P 3980 1195 1980 990 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /SL-K /0502P 3980 1195 1980 1060 1000 1000 1000 1000 F 2"1/2 - -

ELCA_Engine ver.4.2.2.0 11.1.2 NX-G06 0202P - 0812P_201904_EN R454B


DIMENSIONAL DRAWINGS NX-G06 0202P - 0812P
[ SI System ]

DIMENSIONS AND HEAT EXCHANGER HEAT RECOVERY EX.


CLEARANCE
WEIGHTS USER SIDE USER SIDE
SIZE
A B H WEIGHT R1 R2 R3 R4 IN/OUT IN/OUT
[mm] [mm] [mm] [kg] [mm] [mm] [mm] [mm] TYPE Ø TYPE Ø
NX-G06 /SL-K /0552P 3980 1195 1980 1070 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /SL-K /0602P 3980 1195 1980 1110 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /D /SL-K /0202P 2395 1195 1865 590 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /SL-K /0252P 2825 1195 1980 700 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /SL-K /0262P 2825 1195 1980 710 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /SL-K /0302P 2825 1195 1980 710 1000 1000 1000 1000 F 2" B 1" 1/4
NX-G06 /D /SL-K /0352P 3360 1195 1980 810 1000 1000 1000 1000 F 2" B 1" 1/4
NX-G06 /D /SL-K /0402P 3360 1195 1980 830 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /SL-K /0452P 3980 1195 1980 990 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /SL-K /0502P 3980 1195 1980 1060 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /SL-K /0552P 3980 1195 1980 1070 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /SL-K /0602P 3980 1195 1980 1110 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /CA /0202P 2395 1195 1865 580 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /CA /0252P 2395 1195 1865 590 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /CA /0262P 2395 1195 1865 600 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /CA /0302P 2825 1195 1980 710 1000 1000 1000 1000 F 2" - -
NX-G06 /CA /0352P 3360 1195 1980 780 1000 1000 1000 1000 F 2" - -
NX-G06 /CA /0402P 3360 1195 1980 830 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /CA /0452P 3360 1195 1980 920 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /CA /0502P 3980 1195 1980 1060 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /D /CA /0202P 2395 1195 1865 580 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /CA /0252P 2395 1195 1865 590 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /CA /0262P 2395 1195 1865 600 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /CA /0302P 2825 1195 1980 710 1000 1000 1000 1000 F 2" B 1" 1/4
NX-G06 /D /CA /0352P 3360 1195 1980 780 1000 1000 1000 1000 F 2" B 1" 1/4
NX-G06 /D /CA /0402P 3360 1195 1980 830 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /CA /0452P 3360 1195 1980 920 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /CA /0502P 3980 1195 1980 1060 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /LN-CA /0202P 2395 1195 1865 590 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /LN-CA /0252P 2825 1195 1980 700 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /LN-CA /0262P 2825 1195 1980 710 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /LN-CA /0302P 3360 1195 1980 780 1000 1000 1000 1000 F 2" - -
NX-G06 /LN-CA /0352P 3360 1195 1980 820 1000 1000 1000 1000 F 2" - -
NX-G06 /LN-CA /0402P 3980 1195 1980 920 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /LN-CA /0452P 3980 1195 1980 990 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /LN-CA /0502P 3980 1195 1980 1070 1000 1000 1000 1000 F 2"1/2 - -
NX-G06 /D /LN-CA /0202P 2395 1195 1865 590 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /LN-CA /0252P 2825 1195 1980 700 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /LN-CA /0262P 2825 1195 1980 710 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /LN-CA /0302P 3360 1195 1980 780 1000 1000 1000 1000 F 2" B 1" 1/4
NX-G06 /D /LN-CA /0352P 3360 1195 1980 820 1000 1000 1000 1000 F 2" B 1" 1/4
NX-G06 /D /LN-CA /0402P 3980 1195 1980 920 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /LN-CA /0452P 3980 1195 1980 990 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /D /LN-CA /0502P 3980 1195 1980 1070 1000 1000 1000 1000 F 2"1/2 B 1" 1/4
NX-G06 /SL-CA /0202P 2825 1195 1980 700 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /SL-CA /0252P 3360 1195 1980 790 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /SL-CA /0262P 3360 1195 1980 800 1000 1000 1000 1000 F 1"1/2 - -
NX-G06 /SL-CA /0302P 3360 1195 1980 810 1000 1000 1000 1000 F 2" - -
NX-G06 /SL-CA /0352P 3980 1195 1980 890 1000 1000 1000 1000 F 2" - -
NX-G06 /D /SL-CA /0202P 2825 1195 1980 700 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /SL-CA /0252P 3360 1195 1980 790 1000 1000 1000 1000 F 1"1/2 B 1" 1/4
NX-G06 /D /SL-CA /0262P 3360 1195 1980 800 1000 1000 1000 1000 F 1"1/2 B 1" 1/4

ELCA_Engine ver.4.2.2.0 11.1.3 NX-G06 0202P - 0812P_201904_EN R454B


DIMENSIONAL DRAWINGS NX-G06 0202P - 0812P
[ SI System ]

DIMENSIONS AND HEAT EXCHANGER HEAT RECOVERY EX.


CLEARANCE
WEIGHTS USER SIDE USER SIDE
SIZE
A B H WEIGHT R1 R2 R3 R4 IN/OUT IN/OUT
[mm] [mm] [mm] [kg] [mm] [mm] [mm] [mm] TYPE Ø TYPE Ø
NX-G06 /D /SL-CA /0302P 3360 1195 1980 810 1000 1000 1000 1000 F 2" B 1" 1/4
NX-G06 /D /SL-CA /0352P 3980 1195 1980 890 1000 1000 1000 1000 F 2" B 1" 1/4

ELCA_Engine ver.4.2.2.0 11.1.4 NX-G06 0202P - 0812P_201904_EN R454B


ELCA_Engine ver.4.2.2.0
DIMENSIONAL DRAWINGS

11.1.5
NX-G06 0202P - 0812P

NX-G06 0202P - 0812P_201904_EN


REMARKS:For installation purposes, please refer to the documentation sent after the purchase-contract. This technical data should be considered as indicative. Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A. may modify them at any moment. Data valid for
standard units without any additional option.

R454B
DIMENSIONAL DRAWINGS NX-G06 0202P - 0812P
[ SI System ]

DIMENSIONS AND HEAT EXCHANGER HEAT RECOVERY EX.


CLEARANCE
WEIGHTS USER SIDE USER SIDE
SIZE
A B H WEIGHT R1 R2 R3 R4 IN/OUT IN/OUT
[mm] [mm] [mm] [kg] [mm] [mm] [mm] [mm] TYPE Ø TYPE Ø
NX-G06 /CA /0562P 3160 2250 2170 1460 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /CA /0612P 3160 2250 2170 1480 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /CA /0712P 3160 2250 2170 1490 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /CA /0812P 4335 2250 2170 1750 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /D /CA /0562P 3160 2250 2170 1460 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /CA /0612P 3160 2250 2170 1480 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /CA /0712P 3160 2250 2170 1490 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /CA /0812P 4335 2250 2170 1750 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /LN-CA /0562P 3160 2250 2170 1460 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /LN-CA /0612P 3160 2250 2170 1480 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /LN-CA /0712P 4335 2250 2170 1730 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /LN-CA /0812P 4335 2250 2170 1810 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /D /LN-CA /0562P 3160 2250 2170 1460 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /LN-CA /0612P 3160 2250 2170 1480 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /LN-CA /0712P 4335 2250 2170 1730 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /LN-CA /0812P 4335 2250 2170 1810 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /SL-CA /0412P 3160 2250 2170 1280 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /SL-CA /0462P 3160 2250 2170 1370 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /SL-CA /0512P 3160 2250 2170 1440 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /SL-CA /0562P 4335 2250 2170 1690 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /SL-CA /0612P 4335 2250 2170 1750 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /SL-CA /0712P 4335 2250 2170 1770 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /SL-CA /0812P 5510 2250 2170 2070 1500 2300 1500 1500 F 2"1/2 - -
NX-G06 /D /SL-CA /0412P 3160 2250 2170 1280 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /SL-CA /0462P 3160 2250 2170 1370 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /SL-CA /0512P 3160 2250 2170 1440 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /SL-CA /0562P 4335 2250 2170 1690 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /SL-CA /0612P 4335 2250 2170 1750 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /SL-CA /0712P 4335 2250 2170 1770 1500 2300 1500 1500 F 2"1/2 B 1" 1/4
NX-G06 /D /SL-CA /0812P 5510 2250 2170 2070 1500 2300 1500 1500 F 2"1/2 B 1" 1/4

ELCA_Engine ver.4.2.2.0 11.1.6 NX-G06 0202P - 0812P_201904_EN R454B


DIMENSIONAL DRAWINGS

LEGEND OF PIPE CONNECTIONS

PIPE PIPE
NOMINAL NOMINAL
OUTSIDE OUTSIDE
PIPE SIZE PIPE SIZE
DIAMETER DIAMETER
ø inches ø mm ø inches ø mm
¾ 26,7 4 114,3
1 33,7 4½ 127,0
1¼ 42,4 5 139,7
1½ 48,3 6 168,3
2 60,3 8 219,1
TYPE = B TYPE = F
2½ 76,1 10 273,0
Male threaded pipe Grooved coupling with male
threaded counter-pipe user side 3 88,9 12 323,9
3½ 101,6 14 355,6

UNI ISO 228/13


Pipe threads where pressure-tight joints are not made on the threads - Designation, dimensions and tolerances
Used terminology:
G: Pipe threads where pressure-tight joints are not made on the threads
A: Close tolerance class for external pipe threads where pressure-tight joints are not made on the threads
B: Wider tolerance class for external pipe threads where pressure-tight joints are not made on the threads
Internal threads: G letter followed by thread mark (only tolerance class)
External threads: G letter followed by thread mark and by A letter for A class external threads or by B letter for B class external threads.

UNI EN 10226-1
Pipe threads where pressure-tight joints are made on the threads - Designation, dimensions and tolerances
Used terminology:
Rp: Internal cylindrical threads where pressure-tight joints are made on the threads
Rc: Internal conical threads where pressure-tight joints are made on the threads
R: External conical threads where pressure-tight joints are made on the threads
Internal cylindrical threads: R letter followed by p letter
Internal conical threads: R letter followed by c letter
External conical threads: R letter

DESIGNATION DESCRIPTION
Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standard UNI ISO 7/1
UNI EN 10226-1 - Rp 1 1/2
Conventional ø 1 1/2”
Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standard UNI ISO 7/1
UNI EN 10226-1 - Rp 2 1/2
Conventional ø 2 1/2”
Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standard UNI ISO 7/1
UNI EN 10226-1 - Rp 3
Conventional ø 3”
External conical threads where pressure-tight joints are made on the threads, defined by standard UNI ISO 7/1
UNI EN 10226-1 - R 3
Conventional ø 3”
Internal cylindrical threads where pressure-tight joints are not made on the threads, defined by standard
UNI ISO 228/1
UNI ISO 228/1 - G 4 B
Tolerance class B for external thread
Conventional ø 4”
Flange Nominal Diameter: 80 mm
DN 80 PN 16
Nominal Pressure: 16 bar

NOTE:
Conventional diameter value [in inches] identifies short thread designation, based upon the relative standard.
All relative values are defined by standards.
As example, here below some values:

UNI EN 10226-1 UNI ISO 228/1


Conventional ø 1” 1”
Pitch 2.309 mm 2.309 mm
External ø 33.249 mm 33.249 mm
Core ø 30.291 mm 30.291 mm
Thread height 1.479 mm 1.479 mm

ELCA_Engine ver.4.2.2.0 11.1.7 NX-G06 0202P - 0812P_201904_EN R454B


12.1 HYDRONIC GROUP

12.1 HYDRONIC GROUP Versions


The hydronic group consists of: PUMP GROUP
- 1 or 2 pumps, 2 poles, low or high head CA K LN-CA LN-K SL-CA SL-K
- 10 mm insulation lining on pumps and pipes HYDRONIC KIT 1 PUMP
- pump inlet / oulet valves 2 POLES HH + X X X X X X
- check valves (only for twin end-suction pumps) TANK(3153)
- drain valve HYDRONIC KIT 2
- air vent PUMPS 2 POLES LH + X X X X X X
- safety valve calibrated to 8 bar (longitudinal-V shaped units) or 10 TANK(3155)
bar (Horizontal-V shaped units)
HYDRONIC KIT 2
PUMPS 2 POLES HH + X X X X X X
Each of the components of the hydraulic group has been designed to TANK(3156)
optimise hydraulic and electrical installation space,
time and costs. HYDRONIC KIT 1 PUMP
2 POLES LH(3164) X X X X X X
The hydronic group is protected by a special casing ventilating
(versions LN and SL). HYDRONIC KIT 1 PUMP
2 POLES HH(3165) X X X X X X
In case of twin pumps, the second pump operates in stand-by to the
first. The relative operating hours of the two pumps are balanced. In HYDRONIC KIT 2
case the operating pump breaks down, the reserve pump is PUMPS 2 POLES X X X X X X
automatically enabled. LH(3167)
The electrical panel of the unit is protected with fuses and contactors
HYDRONIC KIT 2
with thermals cut-out. PUMPS 2 POLES X X X X X X
The hydronic kit of the units with Longitudinal-V structure includes HH(3168)
end-suction pumps, the one of the units with Horizontal-V structure
includes in-line pumps.

12.1 BUFFER TANK


The buffer tank system features: Storage tank combinations
- buffer tank, which capacity depends on the unit size (see the ACCUMULATION
dedicated table) Version Capacity
- 20 mm insulation lining on buffer tank [l]
- expansion vessel (EPDM membrane), with 2,5 bar pre-charge CA
- safety valve calibrated to 5 bars (Longitudinal-V shaped units) or 6
bars (Horizontal V-shaped units) LN-CA
- pressure gauge LN-K 140
- filling valve 0202P
SL-CA
- drain valve
- air vent SL-K
K 90
12.1 END-SUCTION PUMPS
Low or high head pumps CA
Horizontal one-piece centrifuge pump, normalised to EN 733, axial
K
suction and radial delivery, in single or twin version. Pump with cast
iron body and AISI 316L stainless steel impeller. The section of the LN-CA 140
shaft in contact with the liquid is made from stainless steel. 0252P
LN-K
Mechanical seal with components in: ceramic/carbon/EPDM.
Three-phase electric motor protected to IP55, insulation class F, SL-K
suitable for continuous service. SL-CA 200

12.1 IN-LINE PUMPS CA


Low or high head pumps K
Centrifugal pumps with in-line suction and delivery flanges, in single
or twin versions. Pump body in cast iron and impeller in AISI 316L LN-CA 140
0262P
stainless steel or cast-iron, entirely laser technology welded. LN-K
Mechanical seal with EPDM elastomers. Three-phase electric motor
SL-K
protected to IP55, insulation class F, suitable for continuous service.
SL-CA 200
12.1 SPECIAL PUMPS CA
For pumps with different configurations, please contact our sales
department. K
140
LN-K
12.1 OTHER COMPONENTS 0302P
The hydronic kits do not include the following accessories though SL-K
these are recommended to ensure correct system operation:
LN-CA
- Flow-out switch 200
- Pressure gauges upline and downline from the unit SL-CA
- Flexible joints on piping CA
- On-off valves
- Outlet control thermometer LN-CA 200
- Mains filter. SL-K
0352P
K
140
LN-K
Possible configurations SL-CA 250
Versions CA
PUMP GROUP 200
CA K LN-CA LN-K SL-CA SL-K SL-K
HYDRONIC KIT 1 PUMP 0402P
K
2 POLES LH + X X X X X X 140
TANK(3152) LN-K

ELCA_Engine ver.4.2.2.0 12.1.1 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

ACCUMULATION
Version Capacity
[l]
0402P LN-CA 250
0412P SL-CA 500
CA
200
LN-K
0452P K 140
LN-CA
250
SL-K
0462P SL-CA 500
CA
LN-CA 250
0502P SL-K
K 140
LN-K 200
0512P SL-CA 500
K
200
0552P LN-K
SL-K 250
CA
0562P LN-CA 500
SL-CA
K
0602P LN-K 250
SL-K
CA
0612P LN-CA 500
SL-CA
K
0702P 250
LN-K
CA
0712P LN-CA 500
SL-CA
CA
0812P LN-CA 500
SL-CA

ELCA_Engine ver.4.2.2.0 12.1.2 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

ELCA_Engine ver.4.2.2.0 12.1.3 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

Hydronic kit positioning

HYDRONIC KIT 1 PUMP 2 POLES HYDRONIC KIT 1 PUMP 2 POLES HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2
LH + TANK (3152) HH + TANK (3153) POLES LH + TANK (3155) POLES HH + TANK (3156)
Version extra L extra W extra H extra extra L extra W extra H extra extra L extra W extra H extra extra L extra W extra H extra
[mm] [mm] [mm] WGT [mm] [mm] [mm] WGT [mm] [mm] [mm] WGT [mm] [mm] [mm] WGT
[kg] [kg] [kg] [kg]
CA / / / 320 / / / 320 / / / 320 / / / 320
K / / / 250 / / / 250 / / / 250 / / / 250
LN-CA / / / 310 / / / 310 / / / 310 / / / 310
0202P
LN-K / / / 320 / / / 320 / / / 320 / / / 320
SL-CA / / / 210 / / / 210 / / / 210 / / / 210
SL-K / / / 310 / / / 310 / / / 310 / / / 310
CA / / / 320 / / / 320 / / / 320 / / / 320
K / / / 320 / / / 320 / / / 320 / / / 320
LN-CA / / / 330 / / / 330 / / / 330 / / / 330
0252P
LN-K / / / 310 / / / 310 / / / 310 / / / 310
SL-CA / / / 410 / / / 410 / / / 410 / / / 410
SL-K / / / 320 / / / 320 / / / 320 / / / 320
CA / / / 310 / / / 310 / / / 310 / / / 310
K / / / 310 / / / 310 / / / 310 / / / 310
LN-CA / / / 320 / / / 320 / / / 320 / / / 320
0262P
LN-K / / / 320 / / / 320 / / / 320 / / / 320
SL-CA / / / 410 / / / 410 / / / 410 / / / 410
SL-K / / / 320 / / / 320 / / / 320 / / / 320
CA / / / 320 / / / 320 / / / 320 / / / 320
K / / / 320 / / / 320 / / / 320 / / / 320
LN-CA / / / 410 / / / 410 / / / 410 / / / 410
0302P
LN-K / / / 320 / / / 320 / / / 320 / / / 320
SL-CA / / / 400 / / / 400 / / / 400 / / / 400
SL-K / / / 330 / / / 330 / / / 330 / / / 330
CA / / / 480 / / / 480 / / / 480 / / / 480
K / / / 380 / / / 380 / / / 380 / / / 380
LN-CA / / / 480 / / / 480 / / / 480 / / / 480
0352P
LN-K / / / 380 / / / 380 / / / 380 / / / 380
SL-CA / / / 560 / / / 560 / / / 560 / / / 560
SL-K / / / 480 / / / 480 / / / 480 / / / 480
CA / / / 480 / / / 480 / / / 480 / / / 480
K / / / 390 / / / 390 / / / 390 / / / 390
0402P LN-CA / / / 550 / / / 550 / / / 550 / / / 550
LN-K / / / 390 / / / 390 / / / 390 / / / 390
SL-K / / / 480 / / / 480 / / / 480 / / / 480
0412P SL-CA / / / 860 / / / 860 / / / 860 / / / 860
CA / / / 480 / / / 480 / / / 480 / / / 480
K / / / 390 / / / 390 / / / 390 / / / 390
0452P
LN-CA / / / 560 / / / 560 / / / 560 / / / 560
LN-K / / / 480 / / / 480 / / / 480 / / / 480

extra L Unit's extra length


extra W Unit's extra operating width (NOT to be considered for transport)
extra H Unit's extra height
extra H Unit's extra weight (pumps and piping)
HYDRONIC KIT 1 PUMP 2 HYDRONIC KIT 1 PUMP 2 POLES LH + TANK
POLES LH + TANK
HYDRONIC KIT 1 PUMP 2 HYDRONIC KIT 1 PUMP 2 POLES HH + TANK
POLES HH + TANK
HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2 POLES LH + TANK
POLES LH + TANK
HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2 POLES HH + TANK
POLES HH + TANK
- Not available

ELCA_Engine ver.4.2.2.0 12.1.4 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

Hydronic kit positioning

HYDRONIC KIT 1 PUMP 2 POLES HYDRONIC KIT 1 PUMP 2 POLES HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2
LH + TANK (3152) HH + TANK (3153) POLES LH + TANK (3155) POLES HH + TANK (3156)
Version extra L extra W extra H extra extra L extra W extra H extra extra L extra W extra H extra extra L extra W extra H extra
[mm] [mm] [mm] WGT [mm] [mm] [mm] WGT [mm] [mm] [mm] WGT [mm] [mm] [mm] WGT
[kg] [kg] [kg] [kg]
0452P SL-K / / / 560 / / / 560 / / / 560 / / / 560
0462P SL-CA / / / 850 / / / 850 / / / 850 / / / 850
CA / / / 560 / / / 560 / / / 560 / / / 560
K / / / 390 / / / 390 / / / 390 / / / 390
0502P LN-CA / / / 550 / / / 550 / / / 550 / / / 550
LN-K / / / 480 / / / 480 / / / 480 / / / 480
SL-K / / / 560 / / / 560 / / / 560 / / / 560
0512P SL-CA / / / 860 / / / 860 / / / 860 / / / 860
K / / / 480 / / / 480 / / / 480 / / / 480
0552P LN-K / / / 470 / / / 470 / / / 470 / / / 470
SL-K / / / 550 / / / 550 / / / 550 / / / 550
CA / / / 860 / / / 860 / / / 860 / / / 860
0562P LN-CA / / / 860 / / / 860 / / / 860 / / / 860
SL-CA / / / 860 / / / 860 / / / 860 / / / 860
K / / / 550 / / / 550 / / / 550 / / / 550
0602P LN-K / / / 550 / / / 550 / / / 550 / / / 550
SL-K / / / 550 / / / 550 / / / 550 / / / 550
CA / / / 860 / / / 860 / / / 860 / / / 860
0612P LN-CA / / / 860 / / / 860 / / / 860 / / / 860
SL-CA / / / 860 / / / 860 / / / 860 / / / 860
K / / / 560 / / / 560 / / / 560 / / / 560
0702P
LN-K / / / 570 / / / 570 / / / 570 / / / 570
CA / / / 910 / / / 910 / / / 910 / / / 910
0712P LN-CA / / / 910 / / / 910 / / / 910 / / / 910
SL-CA / / / 910 / / / 910 / / / 910 / / / 910
CA / / / 910 / / / 910 / / / 910 / / / 910
0812P LN-CA / / / 910 / / / 910 / / / 910 / / / 910
SL-CA / / / 910 / / / 910 / / / 910 / / / 910

extra L Unit's extra length


extra W Unit's extra operating width (NOT to be considered for transport)
extra H Unit's extra height
extra H Unit's extra weight (pumps and piping)
HYDRONIC KIT 1 PUMP 2 HYDRONIC KIT 1 PUMP 2 POLES LH + TANK
POLES LH + TANK
HYDRONIC KIT 1 PUMP 2 HYDRONIC KIT 1 PUMP 2 POLES HH + TANK
POLES HH + TANK
HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2 POLES LH + TANK
POLES LH + TANK
HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2 POLES HH + TANK
POLES HH + TANK
- Not available

ELCA_Engine ver.4.2.2.0 12.1.5 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

Hydronic kit positioning

HYDRONIC KIT 1 PUMP 2 POLES HYDRONIC KIT 1 PUMP 2 POLES HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2
LH (3164) HH (3165) POLES LH (3167) POLES HH (3168)
Version extra L extra W extra H extra extra L extra W extra H extra extra L extra W extra H extra extra L extra W extra H extra
[mm] [mm] [mm] WGT [mm] [mm] [mm] WGT [mm] [mm] [mm] WGT [mm] [mm] [mm] WGT
[kg] [kg] [kg] [kg]
CA / / / 120 / / / 120 / / / 120 / / / 120
K / / / 110 / / / 110 / / / 110 / / / 110
LN-CA / / / 120 / / / 120 / / / 120 / / / 120
0202P
LN-K / / / 120 / / / 120 / / / 120 / / / 120
SL-CA / / / 110 / / / 110 / / / 110 / / / 110
SL-K / / / 110 / / / 110 / / / 110 / / / 110
CA / / / 120 / / / 120 / / / 120 / / / 120
K / / / 120 / / / 120 / / / 120 / / / 120
LN-CA / / / 130 / / / 130 / / / 130 / / / 130
0252P
LN-K / / / 110 / / / 110 / / / 110 / / / 110
SL-CA / / / 130 / / / 130 / / / 130 / / / 130
SL-K / / / 120 / / / 120 / / / 120 / / / 120
CA / / / 110 / / / 110 / / / 110 / / / 110
K / / / 120 / / / 120 / / / 120 / / / 120
LN-CA / / / 120 / / / 120 / / / 120 / / / 120
0262P
LN-K / / / 120 / / / 120 / / / 120 / / / 120
SL-CA / / / 130 / / / 130 / / / 130 / / / 130
SL-K / / / 120 / / / 120 / / / 120 / / / 120
CA / / / 120 / / / 120 / / / 120 / / / 120
K / / / 120 / / / 120 / / / 120 / / / 120
LN-CA / / / 120 / / / 120 / / / 120 / / / 120
0302P
LN-K / / / 120 / / / 120 / / / 120 / / / 120
SL-CA / / / 120 / / / 120 / / / 120 / / / 120
SL-K / / / 130 / / / 130 / / / 130 / / / 130
CA / / / 200 / / / 200 / / / 200 / / / 200
K / / / 180 / / / 180 / / / 180 / / / 180
LN-CA / / / 190 / / / 190 / / / 190 / / / 190
0352P
LN-K / / / 190 / / / 190 / / / 190 / / / 190
SL-CA / / / 210 / / / 210 / / / 210 / / / 210
SL-K / / / 200 / / / 200 / / / 200 / / / 200
CA / / / 200 / / / 200 / / / 200 / / / 200
K / / / 190 / / / 190 / / / 190 / / / 190
0402P LN-CA / / / 200 / / / 200 / / / 200 / / / 200
LN-K / / / 190 / / / 190 / / / 190 / / / 190
SL-K / / / 200 / / / 200 / / / 200 / / / 200
0412P SL-CA / / / 190 / / / 190 / / / 190 / / / 190
CA / / / 190 / / / 190 / / / 190 / / / 190
K / / / 190 / / / 190 / / / 190 / / / 190
0452P
LN-CA / / / 210 / / / 210 / / / 210 / / / 210
LN-K / / / 190 / / / 190 / / / 190 / / / 190

extra L Unit's extra length


extra W Unit's extra operating width (NOT to be considered for transport)
extra H Unit's extra height
extra H Unit's extra weight (pumps and piping)
HYDRONIC KIT 1 PUMP 2 HYDRONIC KIT 1 PUMP 2 POLES LH
POLES LH
HYDRONIC KIT 1 PUMP 2 HYDRONIC KIT 1 PUMP 2 POLES HH
POLES HH
HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2 POLES LH
POLES LH
HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2 POLES HH
POLES HH
- Not available

ELCA_Engine ver.4.2.2.0 12.1.6 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

Hydronic kit positioning

HYDRONIC KIT 1 PUMP 2 POLES HYDRONIC KIT 1 PUMP 2 POLES HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2
LH (3164) HH (3165) POLES LH (3167) POLES HH (3168)
Version extra L extra W extra H extra extra L extra W extra H extra extra L extra W extra H extra extra L extra W extra H extra
[mm] [mm] [mm] WGT [mm] [mm] [mm] WGT [mm] [mm] [mm] WGT [mm] [mm] [mm] WGT
[kg] [kg] [kg] [kg]
0452P SL-K / / / 210 / / / 210 / / / 210 / / / 210
0462P SL-CA / / / 190 / / / 190 / / / 190 / / / 190
CA / / / 210 / / / 210 / / / 210 / / / 210
K / / / 190 / / / 190 / / / 190 / / / 190
0502P LN-CA / / / 210 / / / 210 / / / 210 / / / 210
LN-K / / / 200 / / / 200 / / / 200 / / / 200
SL-K / / / 210 / / / 210 / / / 210 / / / 210
0512P SL-CA / / / 190 / / / 190 / / / 190 / / / 190
K / / / 200 / / / 200 / / / 200 / / / 200
0552P LN-K / / / 190 / / / 190 / / / 190 / / / 190
SL-K / / / 200 / / / 200 / / / 200 / / / 200
CA / / / 190 / / / 190 / / / 190 / / / 190
0562P LN-CA / / / 190 / / / 190 / / / 190 / / / 190
SL-CA / / / 170 / / / 170 / / / 170 / / / 170
K / / / 200 / / / 200 / / / 200 / / / 200
0602P LN-K / / / 200 / / / 200 / / / 200 / / / 200
SL-K / / / 200 / / / 200 / / / 200 / / / 200
CA / / / 200 / / / 200 / / / 200 / / / 200
0612P LN-CA / / / 200 / / / 200 / / / 200 / / / 200
SL-CA / / / 190 / / / 190 / / / 190 / / / 190
K / / / 220 / / / 220 / / / 220 / / / 220
0702P
LN-K / / / 220 / / / 220 / / / 220 / / / 220
CA / / / 240 / / / 240 / / / 240 / / / 240
0712P LN-CA / / / 240 / / / 240 / / / 240 / / / 240
SL-CA / / / 240 / / / 240 / / / 240 / / / 240
CA / / / 250 / / / 250 / / / 250 / / / 250
0812P LN-CA / / / 240 / / / 240 / / / 240 / / / 240
SL-CA / / / 240 / / / 240 / / / 240 / / / 240

extra L Unit's extra length


extra W Unit's extra operating width (NOT to be considered for transport)
extra H Unit's extra height
extra H Unit's extra weight (pumps and piping)
HYDRONIC KIT 1 PUMP 2 HYDRONIC KIT 1 PUMP 2 POLES LH
POLES LH
HYDRONIC KIT 1 PUMP 2 HYDRONIC KIT 1 PUMP 2 POLES HH
POLES HH
HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2 POLES LH
POLES LH
HYDRONIC KIT 2 PUMPS 2 HYDRONIC KIT 2 PUMPS 2 POLES HH
POLES HH
- Not available

ELCA_Engine ver.4.2.2.0 12.1.7 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 1 PUMP 2 POLES HH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 52,80 2,525 196
K 49,84 2,383 201
LN-CA 52,81 2,525 196
0202P A1 DWC-V 500/2,2 2 5 2,200
LN-K 49,63 2,373 202
SL-CA 53,11 2,540 195
SL-K 50,18 2,400 201
CA 59,95 2,867 204
K 56,52 2,703 210
LN-CA 60,95 2,915 203
0252P B1
LN-K 56,41 2,697 210
SL-CA 59,72 2,856 205
SL-K 56,53 2,703 210
CA 66,81 3,195 201
K 62,39 2,984 207
LN-CA 67,86 3,245 199
0262P B2 DWC-V 500/3 2 6 3,000
LN-K 62,90 3,008 206
SL-CA 66,44 3,177 201
SL-K 63,24 3,024 206
CA 81,64 3,904 190
K 74,51 3,563 200
LN-CA 79,36 3,795 193
0302P B3
LN-K 71,67 3,427 204
SL-CA 78,67 3,762 194
SL-K 74,64 3,569 200
CA 92,73 4,435 211
K 84,98 4,064 234
LN-CA 90,65 4,335 218
0352P C1
LN-K 86,34 4,129 230
SL-CA 90,71 4,338 218
SL-K 84,96 4,063 3D 32-160/2.2 2 5 2,200 234
CA 103,6 4,956 214
K 97,89 4,681 229

0402P LN-CA 103,1 4,932 C2 216


LN-K 95,43 4,564 235
SL-K 96,00 4,591 234

0412P SL-CA 101,8 4,867 D1 LNEE 50-160/40/2 2 8 4,000 211


CA 117,0 5,597 204
K 109,9 5,255 215

0452P LN-CA 115,8 5,538 E1 3D 40-160/3 2 6 3,000 206


LN-K 108,3 5,181 217
SL-K 108,9 5,207 217

0462P SL-CA 113,9 5,447 F1 LNEE 50-160/40/2 2 8 4,000 208


CA 132,3 6,326 194
K 122,3 5,850 209

0502P LN-CA 128,8 6,160 G1 3D 40-160/3 2 6 3,000 199


LN-K 120,2 5,749 212
SL-K 119,4 5,708 213

0512P SL-CA 127,7 6,106 H1 LNEE 50-160/40/2 2 8 4,000 206


K 138,5 6,623 194

0552P LN-K 134,3 6,422 I1 3D 40-160/3 2 6 3,000 200


SL-K 134,9 6,449 200

ELCA_Engine ver.4.2.2.0 12.1.8 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 1 PUMP 2 POLES HH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 153,9 7,361 252

0562P LN-CA 147,8 7,067 J1 LNEE 50-160/55/2 2 11 5,500 259


SL-CA 145,6 6,962 261
K 159,0 7,605 181

0602P LN-K 156,3 7,473 K1 3D 40-160/3 2 6 3,000 185


SL-K 146,9 7,023 197
CA 171,3 8,191 254

0612P LN-CA 165,8 7,931 L1 LNEE 50-160/55/2 2 11 5,500 259


SL-CA 165,4 7,911 259
K 181,9 8,698 241
0702P M1 3D 40-160/4 2 9 4,000
LN-K 172,2 8,237 254
CA 193,2 9,237 247

0712P LN-CA 190,4 9,106 N1 250


SL-CA 187,1 8,945 253
LNEE 50-160/55/2 2 11 5,500
CA 218,0 10,43 222

0812P LN-CA 212,4 10,16 N2 228


SL-CA 208,9 9,989 232

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.4.2.2.0 12.1.9 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP
ELCA_Engine ver.4.2.2.0 12.1.10 NX-G06 0202P - 0812P_201904_EN R454B
HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 1 PUMP 2 POLES HH + TANK


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 52,80 2,525 196
K 49,84 2,383 201
LN-CA 52,81 2,525 196
0202P A1 DWC-V 500/2,2 2 5 2,200
LN-K 49,63 2,373 202
SL-CA 53,11 2,540 195
SL-K 50,18 2,400 201
CA 59,95 2,867 204
K 56,52 2,703 210
LN-CA 60,95 2,915 203
0252P B1
LN-K 56,41 2,697 210
SL-CA 59,72 2,856 205
SL-K 56,53 2,703 210
CA 66,81 3,195 201
K 62,39 2,984 207
LN-CA 67,86 3,245 199
0262P B2 DWC-V 500/3 2 6 3,000
LN-K 62,90 3,008 206
SL-CA 66,44 3,177 201
SL-K 63,24 3,024 206
CA 81,64 3,904 190
K 74,51 3,563 200
LN-CA 79,36 3,795 193
0302P B3
LN-K 71,67 3,427 204
SL-CA 78,67 3,762 194
SL-K 74,64 3,569 200
CA 92,73 4,435 211
K 84,98 4,064 234
LN-CA 90,65 4,335 218
0352P C1
LN-K 86,34 4,129 230
SL-CA 90,71 4,338 218
SL-K 84,96 4,063 3D 32-160/2.2 2 5 2,200 234
CA 103,6 4,956 214
K 97,89 4,681 229

0402P LN-CA 103,1 4,932 C2 216


LN-K 95,43 4,564 235
SL-K 96,00 4,591 234

0412P SL-CA 101,8 4,867 D1 LNEE 50-160/40/2 2 8 4,000 209


CA 117,0 5,597 204
K 109,9 5,255 215

0452P LN-CA 115,8 5,538 E1 3D 40-160/3 2 6 3,000 206


LN-K 108,3 5,181 217
SL-K 108,9 5,207 217

0462P SL-CA 113,9 5,447 F1 LNEE 50-160/40/2 2 8 4,000 205


CA 132,3 6,326 194
K 122,3 5,850 209

0502P LN-CA 128,8 6,160 G1 3D 40-160/3 2 6 3,000 199


LN-K 120,2 5,749 212
SL-K 119,4 5,708 213

0512P SL-CA 127,7 6,106 H1 LNEE 50-160/40/2 2 8 4,000 204


K 138,5 6,623 194

0552P LN-K 134,3 6,422 I1 3D 40-160/3 2 6 3,000 200


SL-K 134,9 6,449 200

ELCA_Engine ver.4.2.2.0 12.1.11 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 1 PUMP 2 POLES HH + TANK


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 153,9 7,361 248

0562P LN-CA 147,8 7,067 J1 LNEE 50-160/55/2 2 11 5,500 255


SL-CA 145,6 6,962 257
K 159,0 7,605 181

0602P LN-K 156,3 7,473 K1 3D 40-160/3 2 6 3,000 185


SL-K 146,9 7,023 197
CA 171,3 8,191 249

0612P LN-CA 165,8 7,931 L1 LNEE 50-160/55/2 2 11 5,500 254


SL-CA 165,4 7,911 255
K 181,9 8,698 241
0702P M1 3D 40-160/4 2 9 4,000
LN-K 172,2 8,237 254
CA 193,2 9,237 243

0712P LN-CA 190,4 9,106 N1 245


SL-CA 187,1 8,945 249
LNEE 50-160/55/2 2 11 5,500
CA 218,0 10,43 216

0812P LN-CA 212,4 10,16 N2 223


SL-CA 208,9 9,989 227

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.4.2.2.0 12.1.12 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP
ELCA_Engine ver.4.2.2.0 12.1.13 NX-G06 0202P - 0812P_201904_EN R454B
HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 1 PUMP 2 POLES LH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 52,80 2,525 84,9
K 49,84 2,383 91,7
LN-CA 52,81 2,525 84,9
0202P A1
LN-K 49,63 2,373 92,1
SL-CA 53,11 2,540 84,2
SL-K 50,18 2,400 90,9
DWC-V 300/1,1( R ) 2 3 1,100
CA 59,95 2,867 80,9
K 56,52 2,703 88,1
LN-CA 60,95 2,915 78,7
0252P A2
LN-K 56,41 2,697 88,4
SL-CA 59,72 2,856 81,4
SL-K 56,53 2,703 88,1
CA 66,81 3,195 128
K 62,39 2,984 137
LN-CA 67,86 3,245 125
0262P B1
LN-K 62,90 3,008 136
SL-CA 66,44 3,177 128
SL-K 63,24 3,024 135
DWC-V 300/1,1 2 3 1,100
CA 81,64 3,904 108
K 74,51 3,563 123
LN-CA 79,36 3,795 113
0302P B2
LN-K 71,67 3,427 128
SL-CA 78,67 3,762 114
SL-K 74,64 3,569 123
CA 92,73 4,435 113
K 84,98 4,064 132
LN-CA 90,65 4,335 118
0352P C1
LN-K 86,34 4,129 128
SL-CA 90,71 4,338 118
SL-K 84,96 4,063 DWC-V 300/1,5 2 4 1,500 132
CA 103,6 4,956 121
K 97,89 4,681 133

0402P LN-CA 103,1 4,932 C2 122


LN-K 95,43 4,564 138
SL-K 96,00 4,591 137

0412P SL-CA 101,8 4,867 D1 LNEE 50-125/22/2 2 5 2,200 119


CA 117,0 5,597 105
K 109,9 5,255 119

0452P LN-CA 115,8 5,538 E1 DWC-V 300/1,5 2 4 1,500 107


LN-K 108,3 5,181 122
SL-K 108,9 5,207 121

0462P SL-CA 113,9 5,447 F1 LNEE 50-125/22/2 2 5 2,200 115


CA 132,3 6,326 83,6
K 122,3 5,850 97,2

0502P LN-CA 128,8 6,160 G1 DWC-V 500/1,5 2 4 1,500 88,4


LN-K 120,2 5,749 99,9
SL-K 119,4 5,708 101

0512P SL-CA 127,7 6,106 H1 LNEE 50-125/22/2 2 5 2,200 112


K 138,5 6,623 84,5

0552P LN-K 134,3 6,422 I1 DWC-V 500/1,5 2 4 1,500 90,0


SL-K 134,9 6,449 89,3

ELCA_Engine ver.4.2.2.0 12.1.14 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 1 PUMP 2 POLES LH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 153,9 7,361 133

0562P LN-CA 147,8 7,067 J1 LNEE 50-125/30/2 2 6 3,000 140


SL-CA 145,6 6,962 143
K 159,0 7,605 139

0602P LN-K 156,3 7,473 K1 DWC-V 500/2,2 2 5 2,200 142


SL-K 146,9 7,023 153
CA 171,3 8,191 132

0612P LN-CA 165,8 7,931 L1 LNEE 50-125/30/2 2 6 3,000 138


SL-CA 165,4 7,911 138
K 181,9 8,698 135
0702P M1 DWC-V 500/3 2 6 3,000
LN-K 172,2 8,237 146
CA 193,2 9,237 134

0712P LN-CA 190,4 9,106 N1 137


SL-CA 187,1 8,945 140
LNEE 50-160/30/2 2 6 3,000
CA 218,0 10,43 105

0812P LN-CA 212,4 10,16 N2 112


SL-CA 208,9 9,989 116

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.4.2.2.0 12.1.15 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP
ELCA_Engine ver.4.2.2.0 12.1.16 NX-G06 0202P - 0812P_201904_EN R454B
HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 1 PUMP 2 POLES LH + TANK


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 52,80 2,525 84,9
K 49,84 2,383 91,7
LN-CA 52,81 2,525 84,9
0202P A1
LN-K 49,63 2,373 92,1
SL-CA 53,11 2,540 84,2
SL-K 50,18 2,400 90,9
DWC-V 300/1,1( R ) 2 3 1,100
CA 59,95 2,867 80,9
K 56,52 2,703 88,1
LN-CA 60,95 2,915 78,7
0252P A2
LN-K 56,41 2,697 88,4
SL-CA 59,72 2,856 81,4
SL-K 56,53 2,703 88,1
CA 66,81 3,195 128
K 62,39 2,984 137
LN-CA 67,86 3,245 125
0262P B1
LN-K 62,90 3,008 136
SL-CA 66,44 3,177 128
SL-K 63,24 3,024 135
DWC-V 300/1,1 2 3 1,100
CA 81,64 3,904 108
K 74,51 3,563 123
LN-CA 79,36 3,795 113
0302P B2
LN-K 71,67 3,427 128
SL-CA 78,67 3,762 114
SL-K 74,64 3,569 123
CA 92,73 4,435 113
K 84,98 4,064 132
LN-CA 90,65 4,335 118
0352P C1
LN-K 86,34 4,129 128
SL-CA 90,71 4,338 118
SL-K 84,96 4,063 DWC-V 300/1,5 2 4 1,500 132
CA 103,6 4,956 121
K 97,89 4,681 133

0402P LN-CA 103,1 4,932 C2 122


LN-K 95,43 4,564 138
SL-K 96,00 4,591 137

0412P SL-CA 101,8 4,867 D1 LNEE 50-125/22/2 2 5 2,200 117


CA 117,0 5,597 105
K 109,9 5,255 119

0452P LN-CA 115,8 5,538 E1 DWC-V 300/1,5 2 4 1,500 107


LN-K 108,3 5,181 122
SL-K 108,9 5,207 121

0462P SL-CA 113,9 5,447 F1 LNEE 50-125/22/2 2 5 2,200 113


CA 132,3 6,326 83,6
K 122,3 5,850 97,2

0502P LN-CA 128,8 6,160 G1 DWC-V 500/1,5 2 4 1,500 88,4


LN-K 120,2 5,749 99,9
SL-K 119,4 5,708 101

0512P SL-CA 127,7 6,106 H1 LNEE 50-125/22/2 2 5 2,200 109


K 138,5 6,623 84,5

0552P LN-K 134,3 6,422 I1 DWC-V 500/1,5 2 4 1,500 90,0


SL-K 134,9 6,449 89,3

ELCA_Engine ver.4.2.2.0 12.1.17 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 1 PUMP 2 POLES LH + TANK


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 153,9 7,361 129

0562P LN-CA 147,8 7,067 J1 LNEE 50-125/30/2 2 6 3,000 137


SL-CA 145,6 6,962 139
K 159,0 7,605 139

0602P LN-K 156,3 7,473 K1 DWC-V 500/2,2 2 5 2,200 142


SL-K 146,9 7,023 153
CA 171,3 8,191 127

0612P LN-CA 165,8 7,931 L1 LNEE 50-125/30/2 2 6 3,000 133


SL-CA 165,4 7,911 134
K 181,9 8,698 135
0702P M1 DWC-V 500/3 2 6 3,000
LN-K 172,2 8,237 146
CA 193,2 9,237 129

0712P LN-CA 190,4 9,106 N1 132


SL-CA 187,1 8,945 136
LNEE 50-160/30/2 2 6 3,000
CA 218,0 10,43 98,8

0812P LN-CA 212,4 10,16 N2 106


SL-CA 208,9 9,989 111

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.4.2.2.0 12.1.18 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP
ELCA_Engine ver.4.2.2.0 12.1.19 NX-G06 0202P - 0812P_201904_EN R454B
HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 2 PUMPS 2 POLES HH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 52,80 2,525 192
K 49,84 2,383 198
LN-CA 52,81 2,525 192
0202P A1 DWC-V 500/2,2 2 5 2,200
LN-K 49,63 2,373 199
SL-CA 53,11 2,540 192
SL-K 50,18 2,400 198
CA 59,95 2,867 200
K 56,52 2,703 206
LN-CA 60,95 2,915 198
0252P B1
LN-K 56,41 2,697 206
SL-CA 59,72 2,856 200
SL-K 56,53 2,703 206
CA 66,81 3,195 195
K 62,39 2,984 203
LN-CA 67,86 3,245 193
0262P B2 DWC-V 500/3 2 6 3,000
LN-K 62,90 3,008 202
SL-CA 66,44 3,177 196
SL-K 63,24 3,024 201
CA 81,64 3,904 182
K 74,51 3,563 193
LN-CA 79,36 3,795 186
0302P B3
LN-K 71,67 3,427 198
SL-CA 78,67 3,762 187
SL-K 74,64 3,569 193
CA 92,73 4,435 201
K 84,98 4,064 225
LN-CA 90,65 4,335 208
0352P C1
LN-K 86,34 4,129 221
SL-CA 90,71 4,338 208
SL-K 84,96 4,063 3D 32-160/2.2 2 5 2,200 225
CA 103,6 4,956 209
K 97,89 4,681 224

0402P LN-CA 103,1 4,932 C2 211


LN-K 95,43 4,564 231
SL-K 96,00 4,591 229

0412P SL-CA 101,8 4,867 D1 LNTE 50-160/40/2 2 8 4,000 212


CA 117,0 5,597 198
K 109,9 5,255 209

0452P LN-CA 115,8 5,538 E1 3D 40-160/3 2 6 3,000 200


LN-K 108,3 5,181 212
SL-K 108,9 5,207 211

0462P SL-CA 113,9 5,447 F1 LNTE 50-160/40/2 2 8 4,000 208


CA 132,3 6,326 186
K 122,3 5,850 202

0502P LN-CA 128,8 6,160 G1 3D 40-160/3 2 6 3,000 192


LN-K 120,2 5,749 205
SL-K 119,4 5,708 206

0512P SL-CA 127,7 6,106 H1 LNTE 50-160/40/2 2 8 4,000 206


K 138,5 6,623 186

0552P LN-K 134,3 6,422 I1 3D 40-160/3 2 6 3,000 192


SL-K 134,9 6,449 191

ELCA_Engine ver.4.2.2.0 12.1.20 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 2 PUMPS 2 POLES HH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 153,9 7,361 256

0562P LN-CA 147,8 7,067 J1 LNTE 50-160/55/2 2 11 5,500 262


SL-CA 145,6 6,962 264
K 159,0 7,605 169

0602P LN-K 156,3 7,473 K1 3D 40-160/3 2 6 3,000 174


SL-K 146,9 7,023 187
CA 171,3 8,191 256

0612P LN-CA 165,8 7,931 L1 LNTE 50-160/55/2 2 11 5,500 261


SL-CA 165,4 7,911 262
K 181,9 8,698 226
0702P M1 3D 40-160/4 2 9 4,000
LN-K 172,2 8,237 240
CA 193,2 9,237 247

0712P LN-CA 190,4 9,106 N1 250


SL-CA 187,1 8,945 254
LNTE 50-160/55/2 2 11 5,500
CA 218,0 10,43 219

0812P LN-CA 212,4 10,16 N2 226


SL-CA 208,9 9,989 230

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.4.2.2.0 12.1.21 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP
ELCA_Engine ver.4.2.2.0 12.1.22 NX-G06 0202P - 0812P_201904_EN R454B
HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 2 PUMPS 2 POLES HH + TANK


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 52,80 2,525 192
K 49,84 2,383 198
LN-CA 52,81 2,525 192
0202P A1 DWC-V 500/2,2 2 5 2,200
LN-K 49,63 2,373 199
SL-CA 53,11 2,540 192
SL-K 50,18 2,400 198
CA 59,95 2,867 200
K 56,52 2,703 206
LN-CA 60,95 2,915 198
0252P B1
LN-K 56,41 2,697 206
SL-CA 59,72 2,856 200
SL-K 56,53 2,703 206
CA 66,81 3,195 195
K 62,39 2,984 203
LN-CA 67,86 3,245 193
0262P B2 DWC-V 500/3 2 6 3,000
LN-K 62,90 3,008 202
SL-CA 66,44 3,177 196
SL-K 63,24 3,024 201
CA 81,64 3,904 182
K 74,51 3,563 193
LN-CA 79,36 3,795 186
0302P B3
LN-K 71,67 3,427 198
SL-CA 78,67 3,762 187
SL-K 74,64 3,569 193
CA 92,73 4,435 201
K 84,98 4,064 225
LN-CA 90,65 4,335 208
0352P C1
LN-K 86,34 4,129 221
SL-CA 90,71 4,338 208
SL-K 84,96 4,063 3D 32-160/2.2 2 5 2,200 225
CA 103,6 4,956 209
K 97,89 4,681 224

0402P LN-CA 103,1 4,932 C2 211


LN-K 95,43 4,564 231
SL-K 96,00 4,591 229

0412P SL-CA 101,8 4,867 D1 LNTE 50-160/40/2 2 8 4,000 210


CA 117,0 5,597 198
K 109,9 5,255 209

0452P LN-CA 115,8 5,538 E1 3D 40-160/3 2 6 3,000 200


LN-K 108,3 5,181 212
SL-K 108,9 5,207 211

0462P SL-CA 113,9 5,447 F1 LNTE 50-160/40/2 2 8 4,000 206


CA 132,3 6,326 186
K 122,3 5,850 202

0502P LN-CA 128,8 6,160 G1 3D 40-160/3 2 6 3,000 192


LN-K 120,2 5,749 205
SL-K 119,4 5,708 206

0512P SL-CA 127,7 6,106 H1 LNTE 50-160/40/2 2 8 4,000 204


K 138,5 6,623 186

0552P LN-K 134,3 6,422 I1 3D 40-160/3 2 6 3,000 192


SL-K 134,9 6,449 191

ELCA_Engine ver.4.2.2.0 12.1.23 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 2 PUMPS 2 POLES HH + TANK


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 153,9 7,361 252

0562P LN-CA 147,8 7,067 J1 LNTE 50-160/55/2 2 11 5,500 259


SL-CA 145,6 6,962 261
K 159,0 7,605 169

0602P LN-K 156,3 7,473 K1 3D 40-160/3 2 6 3,000 174


SL-K 146,9 7,023 187
CA 171,3 8,191 251

0612P LN-CA 165,8 7,931 L1 LNTE 50-160/55/2 2 11 5,500 257


SL-CA 165,4 7,911 257
K 181,9 8,698 226
0702P M1 3D 40-160/4 2 9 4,000
LN-K 172,2 8,237 240
CA 193,2 9,237 243

0712P LN-CA 190,4 9,106 N1 246


SL-CA 187,1 8,945 249
LNTE 50-160/55/2 2 11 5,500
CA 218,0 10,43 213

0812P LN-CA 212,4 10,16 N2 220


SL-CA 208,9 9,989 225

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.4.2.2.0 12.1.24 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP
ELCA_Engine ver.4.2.2.0 12.1.25 NX-G06 0202P - 0812P_201904_EN R454B
HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 2 PUMPS 2 POLES LH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 52,80 2,525 81,4
K 49,84 2,383 88,5
LN-CA 52,81 2,525 81,4
0202P A1
LN-K 49,63 2,373 89,0
SL-CA 53,11 2,540 80,6
SL-K 50,18 2,400 87,7
DWC-V 300/1,1( R ) 2 3 1,100
CA 59,95 2,867 76,6
K 56,52 2,703 84,3
LN-CA 60,95 2,915 74,2
0252P A2
LN-K 56,41 2,697 84,5
SL-CA 59,72 2,856 77,1
SL-K 56,53 2,703 84,2
CA 66,81 3,195 122
K 62,39 2,984 132
LN-CA 67,86 3,245 120
0262P B1
LN-K 62,90 3,008 131
SL-CA 66,44 3,177 123
SL-K 63,24 3,024 130
DWC-V 300/1,1 2 3 1,100
CA 81,64 3,904 99,9
K 74,51 3,563 116
LN-CA 79,36 3,795 105
0302P B2
LN-K 71,67 3,427 122
SL-CA 78,67 3,762 107
SL-K 74,64 3,569 116
CA 92,73 4,435 102
K 84,98 4,064 123
LN-CA 90,65 4,335 108
0352P C1
LN-K 86,34 4,129 119
SL-CA 90,71 4,338 108
SL-K 84,96 4,063 DWC-V 300/1,5 2 4 1,500 123
CA 103,6 4,956 116
K 97,89 4,681 128

0402P LN-CA 103,1 4,932 C2 117


LN-K 95,43 4,564 133
SL-K 96,00 4,591 132

0412P SL-CA 101,8 4,867 D1 LNTE 50-125/22/2 2 5 2,200 112


CA 117,0 5,597 98,2
K 109,9 5,255 113

0452P LN-CA 115,8 5,538 E1 DWC-V 300/1,5 2 4 1,500 101


LN-K 108,3 5,181 116
SL-K 108,9 5,207 115

0462P SL-CA 113,9 5,447 F1 LNTE 50-125/22/2 2 5 2,200 107


CA 132,3 6,326 75,3
K 122,3 5,850 90,1

0502P LN-CA 128,8 6,160 G1 DWC-V 500/1,5 2 4 1,500 80,5


LN-K 120,2 5,749 93,1
SL-K 119,4 5,708 94,3

0512P SL-CA 127,7 6,106 H1 LNTE 50-125/22/2 2 5 2,200 102


K 138,5 6,623 75,4

0552P LN-K 134,3 6,422 I1 DWC-V 500/1,5 2 4 1,500 81,5


SL-K 134,9 6,449 80,7

ELCA_Engine ver.4.2.2.0 12.1.26 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 2 PUMPS 2 POLES LH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 153,9 7,361 122

0562P LN-CA 147,8 7,067 J1 LNTE 50-125/30/2 2 6 3,000 129


SL-CA 145,6 6,962 132
K 159,0 7,605 127

0602P LN-K 156,3 7,473 K1 DWC-V 500/2,2 2 5 2,200 131


SL-K 146,9 7,023 143
CA 171,3 8,191 119

0612P LN-CA 165,8 7,931 L1 LNTE 50-125/30/2 2 6 3,000 125


SL-CA 165,4 7,911 126
K 181,9 8,698 119
0702P M1 DWC-V 500/3 2 6 3,000
LN-K 172,2 8,237 133
CA 193,2 9,237 121

0712P LN-CA 190,4 9,106 N1 124


SL-CA 187,1 8,945 128
LNTE 50-160/30/2 2 6 3,000
CA 218,0 10,43 88,3

0812P LN-CA 212,4 10,16 N2 96,0


SL-CA 208,9 9,989 101

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.4.2.2.0 12.1.27 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP
ELCA_Engine ver.4.2.2.0 12.1.28 NX-G06 0202P - 0812P_201904_EN R454B
HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 2 PUMPS 2 POLES LH + TANK


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 52,80 2,525 81,4
K 49,84 2,383 88,5
LN-CA 52,81 2,525 81,4
0202P A1
LN-K 49,63 2,373 89,0
SL-CA 53,11 2,540 80,6
SL-K 50,18 2,400 87,7
DWC-V 300/1,1( R ) 2 3 1,100
CA 59,95 2,867 76,6
K 56,52 2,703 84,3
LN-CA 60,95 2,915 74,2
0252P A2
LN-K 56,41 2,697 84,5
SL-CA 59,72 2,856 77,1
SL-K 56,53 2,703 84,2
CA 66,81 3,195 122
K 62,39 2,984 132
LN-CA 67,86 3,245 120
0262P B1
LN-K 62,90 3,008 131
SL-CA 66,44 3,177 123
SL-K 63,24 3,024 130
DWC-V 300/1,1 2 3 1,100
CA 81,64 3,904 99,9
K 74,51 3,563 116
LN-CA 79,36 3,795 105
0302P B2
LN-K 71,67 3,427 122
SL-CA 78,67 3,762 107
SL-K 74,64 3,569 116
CA 92,73 4,435 102
K 84,98 4,064 123
LN-CA 90,65 4,335 108
0352P C1
LN-K 86,34 4,129 119
SL-CA 90,71 4,338 108
SL-K 84,96 4,063 DWC-V 300/1,5 2 4 1,500 123
CA 103,6 4,956 116
K 97,89 4,681 128

0402P LN-CA 103,1 4,932 C2 117


LN-K 95,43 4,564 133
SL-K 96,00 4,591 132

0412P SL-CA 101,8 4,867 D1 LNTE 50-125/22/2 2 5 2,200 110


CA 117,0 5,597 98,2
K 109,9 5,255 113

0452P LN-CA 115,8 5,538 E1 DWC-V 300/1,5 2 4 1,500 101


LN-K 108,3 5,181 116
SL-K 108,9 5,207 115

0462P SL-CA 113,9 5,447 F1 LNTE 50-125/22/2 2 5 2,200 104


CA 132,3 6,326 75,3
K 122,3 5,850 90,1

0502P LN-CA 128,8 6,160 G1 DWC-V 500/1,5 2 4 1,500 80,5


LN-K 120,2 5,749 93,1
SL-K 119,4 5,708 94,3

0512P SL-CA 127,7 6,106 H1 LNTE 50-125/22/2 2 5 2,200 99,6


K 138,5 6,623 75,4

0552P LN-K 134,3 6,422 I1 DWC-V 500/1,5 2 4 1,500 81,5


SL-K 134,9 6,449 80,7

ELCA_Engine ver.4.2.2.0 12.1.29 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 2 PUMPS 2 POLES LH + TANK


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
CA 153,9 7,361 118

0562P LN-CA 147,8 7,067 J1 LNTE 50-125/30/2 2 6 3,000 125


SL-CA 145,6 6,962 128
K 159,0 7,605 127

0602P LN-K 156,3 7,473 K1 DWC-V 500/2,2 2 5 2,200 131


SL-K 146,9 7,023 143
CA 171,3 8,191 114

0612P LN-CA 165,8 7,931 L1 LNTE 50-125/30/2 2 6 3,000 121


SL-CA 165,4 7,911 121
K 181,9 8,698 119
0702P M1 DWC-V 500/3 2 6 3,000
LN-K 172,2 8,237 133
CA 193,2 9,237 116

0712P LN-CA 190,4 9,106 N1 120


SL-CA 187,1 8,945 124
LNTE 50-160/30/2 2 6 3,000
CA 218,0 10,43 82,4

0812P LN-CA 212,4 10,16 N2 90,6


SL-CA 208,9 9,989 95,5

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.4.2.2.0 12.1.30 NX-G06 0202P - 0812P_201904_EN R454B


HYDRONIC GROUP
ELCA_Engine ver.4.2.2.0 12.1.31 NX-G06 0202P - 0812P_201904_EN R454B