2/13/24, 11:47 PM                                                           Construction R-value Calculator
Construction R-value Calculator
  This webpage calculates the R-value of walls, roofs and suspended floors for most insulation material R-values. It uses the "isothermal
  planes" method, the same method as used in NZS4214:2006.
  Some of the possible material combinations may not be suitable for actual constructions, i.e. EPS based claddings directly fixed on timber
  framing. Please make sure to select only appropriate material combinations.
  If your construction is not listed, please send an e-mail to designnavigator@gmail.com with a description and a detail drawing (pdf) of it.
  Please select the element type. Then choose the construction details and enter the R-value of the insulation either directly in the text box or
  by choosing a product from the right panel .
   Floors
   Walls
   Roofs
                                                                                                                                    Date: 13/02/2024
           RONIL RESIDENCE                                                                                                          1.40   m²°C/W
        Type: Floor: Raft Slab Floor - H1/AS1 Edition 5 and H1/AS2 Edition 1
             Raft Slab Floor - H1/AS1 Edition 5 and H1/AS2 Edition 1
                                 Table F Slab Insulation (H1 Edition 5) - H1 Acceptable Solutions and Verification Methods
                                            Slab floor area [m²]:                                                     75
                                            Area Perimeter Ratio:                                                    1.97
                                            Perimeter:
                                                     Length*           Masonry               External Wall               Edge
                                                                      Veneer Wall             Thickness*               Insulation
                                                -         11 m                                      90 mm
                                                -          8 m                                      90 mm
                                                -         11 m                                      90 mm
                                                -          8 m                                      90 mm
                                                +
                                                     * required data. If empty the perimeter type will be ignored.
                                                                         Print Page
                                 By using this website you agree to the Design Navigator Terms and Conditions
https://www.designnavigator.solutions/CRC.php                                                                                                       1/1
2/13/24, 11:49 PM                                                         Construction R-value Calculator
            Construction R-value Calculator
  This webpage calculates the R-value of walls, roofs and suspended floors for most insulation material R-values. It uses the "isothermal planes"
  method, the same method as used in NZS4214:2006.
  Some of the possible material combinations may not be suitable for actual constructions, i.e. EPS based claddings directly fixed on timber
  framing. Please make sure to select only appropriate material combinations.
  If your construction is not listed, please send an e-mail to designnavigator@gmail.com with a description and a detail drawing (pdf) of it.
  Please select the element type. Then choose the construction details and enter the R-value of the insulation either directly in the text box or by
  choosing a product from the right panel .
   Floors
   Walls
   Roofs
                                                                                                                                        Date: 13/02/2024
           RONIL RESIDENCE                                                                                                              0.36   m²°C/W
        Type: Roof: Timber framed truss Roof, direct fixed or battened flat Ceiling
               Timber framed truss Roof, direct fixed or battened flat Ceiling   view detail
                                                                       external surface 0.03
                                     Roofing : generic - Metal corrugate Iron with building paper
                                                                          R-value: 0.01
                                                                         Insulation :
                                                                     Timber Frame & Cavity :
                no framing (for example SIP Panels)
                                        Roof Frame Area: 0.0%                                               Cavity Area: 100.0%
                                    Roof space (still air) 0.11                                       Roof space (still air) 0.11
                                           Framing :                                                     Insulation : 2.9
                                         R-value: 0.00
                                                                                                 notched to cover bottom chord
                                          Roof Lining : generic - gypsum Plasterboard 13mm
                                                                          R-value: 0.06
                                                                      internal surface 0.09
                                                               Non-IC-rated recessed downlights
                           Ceiling Area [m²]:  74    Number  of downlights:      25 Clearance from lamp holder side [m]:            2
                                                                        Print Page
                                     By using this website you agree to the Design Navigator Terms and Conditions
https://www.designnavigator.solutions/CRC.php                                                                                                           1/1
2/13/24, 11:48 PM                                                      Construction R-value Calculator
            Construction R-value Calculator
   This webpage calculates the R-value of walls, roofs and suspended floors for most insulation material R-values. It uses the
   "isothermal planes" method, the same method as used in NZS4214:2006.
   Some of the possible material combinations may not be suitable for actual constructions, i.e. EPS based claddings directly
   fixed on timber framing. Please make sure to select only appropriate material combinations.
   If your construction is not listed, please send an e-mail to designnavigator@gmail.com with a description and a detail drawing
   (pdf) of it.
   Please select the element type. Then choose the construction details and enter the R-value of the insulation either directly in
   the text box or by choosing a product from the right panel .
   Floors
   Walls
   Roofs
                                                                                                                              Date: 13/02/2024
           RONIL RESIDENCE                                                                                                    1.97   m²°C/W
         Type: Wall: Timber Frame with vented Cavity
                Timber Frame with vented Cavity          view detail
                                                                  external surface 0.03
                         Cladding : generic - Brick 70mm
                                                                       R-value: 0.06
                                      Air Barrier : generic - Building paper
                                                                      R-value: 0.01
                           Timber Frame & Cavity : 90mm, studs @ 600mm, dwangs @ 800mm
                                     Wall Frame Area: 14.4%                                              Cavity Area: 85.6%
                    15-90mm vented cavity (all R-values on ext. side of          15-90mm vented cavity (all R-values on ext. side of
                             cavity will be halved), R: 0.08                              cavity will be halved), R: 0.08
                                        Framing :                                                   Insulation : 2.1
                                     R-value: 0.75
                                                                                   still Airgap: none
                                                                                                         R-value: 0.00
                                   Wall Lining : generic - Brick 70mm
                                                                    R-value: 0.06
                                                                internal surface 0.09
                                                                   Print Page