0% found this document useful (0 votes)
34 views22 pages

Kudle Lab

This document provides details of the calibration capabilities of Kudale Calibration Laboratory Pvt. Ltd. including measurement ranges and uncertainties for various mechanical instruments such as tachometers, protractors, bore gauges, micrometers, calipers and more across 11 categories at their facility in Pune, India.

Uploaded by

Vikas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views22 pages

Kudle Lab

This document provides details of the calibration capabilities of Kudale Calibration Laboratory Pvt. Ltd. including measurement ranges and uncertainties for various mechanical instruments such as tachometers, protractors, bore gauges, micrometers, calipers and more across 11 categories at their facility in Pune, India.

Uploaded by

Vikas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 22

KUDALE CALIBRATION LABORATORY PVT.LTD.

, VIJAYA-LAXMAN BUILDING, 133D/2,


Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 1 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

LOCATION 1-VIJAYA-LAXMAN BUILDING, 133D/2, PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Permanent Facility
Using Digital
MECHANICAL- Tachometer,
Tachometer ( Non 100 rpm to 90000
1 ACCELERATION Tachometer 7.0 rpm
contact) rpm
AND SPEED Calibrator by
comparison method
Using Digital
MECHANICAL- Tachometer,
Tachometer
2 ACCELERATION Tachometer 10 rpm to 3000 rpm 4.0 rpm
(contact)
AND SPEED Calibrator by
comparison method
MECHANICAL-
DIMENSION
Using Profile
(BASIC Bevel Protractor , 0°
3 projector & Angle 5 ' of arc
MEASURING Combination Set to 360°
gauges
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
0 to 1
(BASIC Electronic Dial
4 Bore Gauge mm(Transmission 2.5 µm
MEASURING Calibration Tester
Range)
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Comparator Stand Using Height
5 0 to 300 mm 7.0 µm
MEASURING 300mmx300 mm Measuring Machine
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 2 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Using Length
(BASIC
6 Depth Micrometer bar,Slip 0 to 300 mm 6 µm
MEASURING
gauge,Surface plate
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Length bar,
(BASIC Depth vernier (L.C.
7 Slip Gauge, Surface 0 to 300 mm 6.8 µm
MEASURING 0.01 mm)
Plate
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Length Bar
(BASIC Depth vernier (L.C.
8 ,Slip Gauge, Surface 300 mm to 600 mm 8.0 µm
MEASURING 0.01 mm)
Plate
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Dial Calibration
(BASIC Tester ( Dial Gauge Using Electronic
9 0 to 25 mm 1.0 µm
MEASURING Calibrator) Probe ,Slip gauges
INSTRUMENT, 0.0002mm
GAUGE ETC.)
MECHANICAL-
DIMENSION
Dial Thickness
(BASIC
10 gauge (L.C. 0.01 Using Slip Gauge 0 to 50 mm 6.4 µm
MEASURING
mm)
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 3 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Using Caliper
(BASIC Digital Vernier 0
11 Checker ,Slip 6.0 µm
MEASURING Caliper ,0.001mm to 150 mm
Gauges
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
Electronic Dial
DIMENSION
Calibration Tester ( Using Electronic
(BASIC 0
12 Dial Gauge probe, Gauge block 1.2 µm
MEASURING to 50 mm
Calibrator) Set
INSTRUMENT,
0.0001mm
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Electronic Probe
13 using Gauge block 0 to 25 mm 0.5 µm
MEASURING 0-25mm ,0.1µm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
Using Height
DIMENSION
Measuring
(BASIC 0
14 Engineer's Sqaure Instrument, Square 6.4 µm
MEASURING to 600 mm
Cylinder LC:
INSTRUMENT,
0.001mm
GAUGE ETC.)
MECHANICAL-
DIMENSION
USing Mic Check
(BASIC External Micrometer 600 mm to 1300
15 Set,Master Setting 6.5 µm
MEASURING (0.01 mm) mm
Rod
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 4 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
(BASIC External Micrometer Using Mic Check Set,
16 0 mm to 100 mm 1.2 µm
MEASURING (L.C. 0.001 mm) Master Setting Rod
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Micrometer
(BASIC External Micrometer
17 Check Set, Master 100 mm to 600 mm 3.0 µm
MEASURING (L.C. 0.001 mm)
Setting Rod
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Electronic 0
18 Feeler gauge 1.0 µm
MEASURING Probe to 2 mm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Electronic
19 Foil 0.01 to 2 mm 1.0 µm
MEASURING Probe
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Electronic
20 Hegman Gauge 0 to 100 µm 1.0 µm
MEASURING Probe
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 5 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION Using Length bars
(BASIC ,Slip gauges ,Surface
21 Height Master 0 to 300 mm 4.0 µm
MEASURING Plate, Electronic
INSTRUMENT, Probe
GAUGE ETC.)
MECHANICAL-
DIMENSION Height Measuring
(BASIC Machine Using Length bars 0 3.0 µm linear, 3.5
22
MEASURING ,LC:0.0001mm linear ,Square cylinder to 1000 mm µm Squareness
INSTRUMENT, ,squareness
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Length
23 Inside dial Caliper 0 to 50 mm 5.0 µm
MEASURING Measuring Machine
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Length
24 Inside Micrometer 50 mm to 500 mm 5.5 µm
MEASURING Measuring Machine
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Inside Micrometer, Using Length
25 0 to 50 mm 4.5 µm
MEASURING L.C. 0.01 micron Measuring Machine
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 6 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
(BASIC Lever Dial Gauge Using Electronic Dial
26 0 to 0.2 mm 2.0 µm
MEASURING (L.C. 0.001 mm) Calibration Tester
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Lever Dial Gauge Electronic Dial
27 0 to 2.0 mm 2.0 µm
MEASURING (L.C. 0.01 mm) Calibration Tester
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Tape And 0 30 SQRT L (Where is
28 Measuring Scale
MEASURING Scale Calibration to 1000 mm in meter) µm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Tape And
(BASIC 0 30.0 SQRT L (where
29 Measuring Tape Scale Calibration
MEASURING to 200 m L is in meter) µm
Unit
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Electronic Probe
(BASIC Micrometer Setting > 100 mm to 600
30 ,Length bar , Gauge 5.0 µm to
MEASURING rod mm
Block Set
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 7 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Using Electronic
(BASIC Micrometer Setting
31 Probe ,Length bar > 600 to 1300 mm 7.3 µm
MEASURING rod
,Gauge Block Set
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Electronic Probe ,
(BASIC Micrometer Setting
32 Length bar ,Gauge 25 to 100 mm 1.7 µm
MEASURING rod
block
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Mikrokator Dial
33 Using Slip Gauge 0 to 0.050 mm 0.8 µm
MEASURING Gauge (comparator)
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Tape And
(BASIC 0 30.0 SQRT L µm
34 Pi tape Scale Calibration
MEASURING to 4000 mm (where L is in meter)
unit
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Electronic
35 Pin Gauge 0.1 to 20 mm 1.0 µm
MEASURING Probe ,Slip Gauge
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 8 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Plain Plug gauge, Electronic Probe,
(BASIC 0
36 Paddle gauge ,OD Slip gauge LC: 1.0 µm
MEASURING to 60 mm
Master 0.0005 mm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Plain Plug Electronic Probe
(BASIC
37 gauge,Paddle gauge ,Slip Gauge LC: 60 mm to 200 mm 1.6 µm
MEASURING
,OD Master 0.0005 mm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Length
(BASIC 1
38 Plain Ring Gauge Measuring Machine , 1.6 µm
MEASURING to 50 mm
Master Setting Ring
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Length
(BASIC
39 Plain Ring Gauge Measuring Machine 50 mm to 200 mm 2.1 µm
MEASURING
,Master Setting Ring
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Dial
(BASIC calibration Tester, 0
40 Plunger Dial Gauge 2.0 µm
MEASURING Electronic Dial to 25 mm
INSTRUMENT, Calibration Tester
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 9 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Using Slip Gauge
(BASIC
41 Plunger Dial Gauge ,Length Measuring 25 mm to 150 mm 1.2 µm
MEASURING
Machine
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Plunger Dial Gauge
(BASIC
42 ,0.0001 mm Using Slip gauges 0 to 50 mm 1.0 µm
MEASURING
(Electronic)
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Profile
43 Radius Gauge 0.4 mm to 50 mm 7.8 µm
MEASURING Projector
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Slip gauges > 300 mm to 500
44 Snap Gauge 8 µm
MEASURING and Length bar mm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Slip gauges > 500 mm to 1000
45 Snap Gauge 12 µm
MEASURING and Length bar mm
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 10 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
(BASIC
46 Snap Gauge Using Slip gauges 1 to 100 mm 1.4 µm
MEASURING
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Slip Gauges
47 Snap Gauge 100 mm to 300 mm 1.6 µm
MEASURING And Length bar
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
sqaure cylinder
(BASIC Square cylinder upto
48 ,sqaureness probe 0 mm to 600 mm 3.5 µm
MEASURING 600 mm
,Proceudre No. 18
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Electronic 0
49 Straight Edge 1.0 SQRT L /125 µm
MEASURING Level to 1000 mm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC 0 to 400mm x400
50 Surface Plate Electronic Level 0.8 vL+W/125 µm
MEASURING mm
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 11 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
0
(BASIC Using Electronic 0.8 SQRT L+W/125
51 Surface Plate to 630 mm x 630
MEASURING Level µm
mm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Electronic 400mm x 400 mm to 0.8 SQRT L+W/125
52 Surface Plate
MEASURING Level 3000mm x 3000 mm µm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Tape And Scale Cal 0
53 Using Length bar 15.0 µm
MEASURING Unit to 1000 mm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
Using Floating
DIMENSION
carriage Micrometer
(BASIC Taper Thread Plug
54 ,Thread Measuring 3 mm to 100 mm 3.5 µm
MEASURING gauge
Wires , Setting
INSTRUMENT,
Master Rods
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Video Measuring 0.025 mm to 3.0
55 Test Sieves 7.5 µm
MEASURING Machine mm
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 12 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
(BASIC using Video
56 Test Sieves 3 mm to 100 mm 50 µm
MEASURING Measuring Machine
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Electronic
(BASIC Thread Measuring
57 probe, Gauge block 0.22 mm to 6.3 mm 0.5 µm
MEASURING Wires
,LMM
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Video
(BASIC
58 Thread Pitch Gauge Measuring Machine, 0.4 to 7.0 mm 5.0 µm
MEASURING
Profile Projector
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Length
(BASIC Measuring Machine
59 Thread Plug Gauge 3 mm to 200 mm 2.5 µm
MEASURING ,Thread Measuring
INSTRUMENT, Wires
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Length
(BASIC 3 mm
60 Thread Ring Gauge Measuring Machine, 1.5 µm
MEASURING to 200 mm
Master Setting Rings
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 13 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Three Point
(BASIC
61 Micrometers,Bore Using Setting Rings 2 mm to 200 mm 4.0 µm
MEASURING
Comparaors
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Height
(BASIC Measuring Machine Using Length bars 0 3.0 µm (linear), 3.5
62
MEASURING ,0.0001mm linear ,Square cylinder to 1000 mm µm (Squareness)
INSTRUMENT, ,Squareness
GAUGE ETC.)
MECHANICAL-
DIMENSION V Blocks for Parallelism: 11.8
Up to 75
(BASIC parallelism Using Height µm, Squareness: 7.8
63 mmx100mmx150m
MEASURING ,squareness Measuring Machine µm, Symmetricity:
m
INSTRUMENT, ,symmetricity 8.3 µm
GAUGE ETC.)
MECHANICAL-
DIMENSION
Vernier Caliper ( Dial Using caliper
(BASIC > 300 mm to 600
64 ,Digital ,Plain ) checker ,gauge 11.0 µm
MEASURING mm
0.01mm block set
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Vernier Caliper ( Dial Caliper Checker,
(BASIC > 600 mm to 1000
65 ,Digital ,Plain ) gauge block, Length 15.3 µm
MEASURING mm
0.01mm bars
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 14 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Vernier Caliper ( Dial Using Caliper
(BASIC > 1000 mm to 2000
66 ,Digital ,Plain ) Checker ,Gauge 20.3 µm
MEASURING mm
0.01mm ,0.02mm block, Length bar
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Vernier Caliper
(BASIC Caliper Checker
67 ,0.01mm 0 to 300 mm 8.9 µm
MEASURING ,Gauge Block Set
(Dial,Digital ,Plain)
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Vernier Height Using Length bar
(BASIC
68 Gauge , L.C 0.01 ,Gauge block 0 to 600 mm 8.3 µm
MEASURING
mm ,Surface Plate
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Vernier Height Using Length bar,
(BASIC 600 mm to 1000
69 Gauge , L.C 0.01 Gauge block 8.5 µm
MEASURING mm
mm ,Surface Plate
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Slip Gauge
70 Caliper Checker 0 to 1000 mm 6.5 µm
(PRECISION ,Length Bar
INSTRUMENTS)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 15 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION Slip Gauge, Length
71 Caliper Checker 0 mm to 600 mm 3.5 µm
(PRECISION Bar
INSTRUMENTS)
MECHANICAL- Using Electronic
DIMENSION Gauge Block probe, Gauge block,
72 up to to 250 mm 3.0 µm
(PRECISION Accessories surface plate ,
INSTRUMENTS) Optical flat
MECHANICAL-
Using Gauge blocks ,
DIMENSION
73 Gauge block Set Gauge Block 0 to 10 mm 0.1 µm
(PRECISION
Comparator
INSTRUMENTS)
MECHANICAL-
Using Gauge blocks,
DIMENSION
74 Gauge block Set Gauge block 10 mm to 50 mm 0.12 µm
(PRECISION
comparator
INSTRUMENTS)
MECHANICAL-
Using Gauge block
DIMENSION
75 Gauge block Set ,Gauge block 50 mm to 100 mm 0.2 µm
(PRECISION
comparator
INSTRUMENTS)
MECHANICAL- Using Length
DIMENSION Length bar / Long measuring machine
76 up to 500 mm 2 µm
(PRECISION Slip Gauge ,Electronic probe
INSTRUMENTS) ,Gauge block
MECHANICAL- Profile Projector ,
Using Glass scale, Linear 3.5 um, Angle
DIMENSION Video Measuring 200*200 mm, 0° to
77 Angle slip gauges, 30 " of arc
(PRECISION Machine ( Linear & 360°, 10X to 100X
Digital Vernier Magnification 0.1 %
INSTRUMENTS) Angle,magnification)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 16 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Rubber hardness
using Electronic
Tester ( Durometer)
MECHANICAL- rubber hardness 10 Shore A,D
78 Shore A,D Using 1.0 %
DUROMETER tester calibrator as to 100 Shore A,D
Spring Force
per ASTM D - 2240
Calibration
MECHANICAL-
Using Dead Weights
MOBILE FORCE Force Gauge (Pull 2N
79 as per VDI/VDE 0.12 %
MEASURING mode) to 1000 N
2624,Part 2.1: 2008
SYSTEM
MECHANICAL- Pressure gauge
PRESSURE Hydraulic Pressure comparator , Digital
80 0 to 70 bar 0.024 bar
INDICATING Gauge pressure gauge
DEVICES ,DKD R6-1
MECHANICAL- Digital Pressure
PRESSURE Hydraulic Pressure Gauge, Pressure
81 0 to 700 bar 0.30 bar
INDICATING Gauge Gauge Calibrator,
DEVICES DKD R6-1
MECHANICAL-
Digital Torque
TORQUE using Dead Weights 1 Nm
82 Wrench (by first 0.61 %
GENERATING ,Beam to 300 Nm
principle) Type I
DEVICES
MECHANICAL-
Torque Wrench Type
TORQUE Torque Sensor With
83 1, Class A, B, C, D & 1 Nm to 300 Nm 1.0 %
GENERATING Indicator
E
DEVICES
MECHANICAL-
Torque Wrench
TORQUE Torque Sensor With
84 (Type II ) Class A B C 300 Nm to 2000 Nm 0.8 %
GENERATING Indicator
&G
DEVICES

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 17 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
Torque Sensor / Using Dead Weights
TORQUE 0.4 Nm
85 Torque Tester with And Beam as per as 0.4 %
MEASURING to 50 Nm
indicator per BS 7882: 2017
DEVICES
MECHANICAL-
Torque Sensor / Dead Weights And
TORQUE
86 Torque Tester with Beam as per BS 50 Nm to 300 Nm 0.3 %
MEASURING
indicator 7882: 2017
DEVICES
MECHANICAL-
UTM, TENSION using Force Proving
Tensile Testing
CREEP AND Instrument (Load
87 Machine 20 N to 20000 N 0.37 %
TORSION cell) as per IS 1828:
(Tensometer)
TESTING 2005
MACHINE

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 18 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

LOCATION 1-VIJAYA-LAXMAN BUILDING, 133D/2, PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Site Facility
MECHANICAL-
DIMENSION Height Measuring
(BASIC Machine Using Length bars 0 3.0 µm linear, 3.5
1
MEASURING ,LC:0.0001mm linear ,Square cylinder to 1000 mm µm Squareness
INSTRUMENT, ,squareness
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Slip Gauge
(BASIC
2 Plunger Dial Gauge ,Length Measuring 25 mm to 150 mm 1.2 µm
MEASURING
Machine
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
sqaure cylinder
(BASIC Square cylinder upto
3 ,sqaureness probe 0 mm to 600 mm 3.5 µm
MEASURING 600 mm
,Proceudre No. 18
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Using Electronic 0
4 Straight Edge 1.0 SQRT L/125 µm
MEASURING Level to 4000 mm
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 19 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
(BASIC Using Electronic 400mm x 400 mm to 0.8 SQRT L+W/125
5 Surface Plate
MEASURING Level 3000mm x 3000 mm µm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
(BASIC Tape And Scale Cal 0
6 Using Length bar 15.0 µm
MEASURING Unit to 1000 mm
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Vernier Caliper ( Dial Using Caliper
(BASIC > 1000 mm to 2000
7 ,Digital ,Plain ) Checker ,Gauge 20.3 µm
MEASURING mm
0.01mm ,0.02mm block, Length bar
INSTRUMENT,
GAUGE ETC.)
MECHANICAL- Profile Projector ,
Using Glass scale, Linear 3.5 um, Angle
DIMENSION Video Measuring 200*200 mm, 0° to
8 Angle slip gauges, 30 " of arc
(PRECISION Machine ( Linear & 360°, 10X to 100X
Digital Vernier Magnification 0.1 %
INSTRUMENTS) Angle,magnification)
MECHANICAL- Pressure gauge
PRESSURE Hydraulic Pressure comparator , Digital
9 0 to 70 bar 0.024 bar
INDICATING Gauge pressure gauge
DEVICES ,DKD R6-1
MECHANICAL- Digital Pressure
PRESSURE Hydraulic Pressure Gauge, Pressure
10 0 to 700 bar 0.30 bar
INDICATING Gauge Gauge Calibrator,
DEVICES DKD R6-1

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 20 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
UTM, TENSION using Force Proving
Tensile Testing
CREEP AND Instrument (Load
11 Machine 20 N to 20000 N 0.37 %
TORSION cell) as per IS 1828:
(Tensometer)
TESTING 2005
MACHINE

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 21 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

LOCATION 2 - PLOT NO. 124,SWAMI VIVEKANAND CO-OPERATIVE INDUSTRIAL ESTATE LTD., S.NO. 54,
HANDEWADI ROAD, HADPSAR, PUNE, MAHARASHTRA, INDIA
Permanent Facility
MECHANICAL-
Using Dead Weights
MOBILE FORCE Force Gauge (Pull
1 as per VDI/VDE 1000 N to 2000 N 0.12 %
MEASURING mode)
2624,Part 2.1: 2008
SYSTEM
MECHANICAL-
Digital Torque
TORQUE Using Dead Weights
2 Wrench (by first 300 Nm to 500 Nm 0.61 %
GENERATING and Beam
principle)
DEVICES
MECHANICAL-
Torque Sensor / Using Dead Weights
TORQUE
3 Torque Tester with And Beam as per BS 300 Nm to 2000 Nm 0.3 %
MEASURING
indicator 7882: 2017
DEVICES

This is annexure to 'Certificate of Accreditation' and does not require any signature.
KUDALE CALIBRATION LABORATORY PVT.LTD., VIJAYA-LAXMAN BUILDING, 133D/2,
Laboratory Name :
PARVATI DARSHAN SOC, PUNE, MAHARASHTRA, INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2156 Page No 22 of 22
Validity 05/04/2022 to 04/04/2024 Last Amended on 28/05/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

LOCATION 2 - PLOT NO. 124,SWAMI VIVEKANAND CO-OPERATIVE INDUSTRIAL ESTATE LTD., S.NO. 54,
HANDEWADI ROAD, HADPSAR, PUNE, MAHARASHTRA, INDIA
Site Facility
* CMCs represent expanded uncertainties expressed at approximately the 95% level of confidence, using a coverage factor of k = 2.

This is annexure to 'Certificate of Accreditation' and does not require any signature.