Security and Communication
ET 908H
          Hybrid modules for integration in housings and panels
                                                                                                      High                     OpenDuplex®                           IoIP® and
                                                                                                     volume                    technology                               SIP
     The perfect built-in solution                                                                       Features and highlights
     The hybrid modules ET 908H (RJ45 jacks mounted horizontally) and                                    –   Built-in inputs and outputs for connection of e.g. door openers – can
     ET 908H-1 (RJ45 jacks mounted vertically) have been developed for                                      be extended via expansion plug
     installation in existing housings or for construction of special Intercom                         –   Hybrid modules for custom designed stations
      stations. As they support both IoIP connections and SIP solutions (hybrid),                        –   Special audio functions ensure superior speech quality in any situation
      the hybrid modules can easily be integrated into any Voice over IP system
                                                                                                         –   Sound output or playback of pre-recorded messages can be used to
      as well as any existing Commend Intercom system. The desired opera-
                                                                                                             provide information and reassurance to callers
      tion mode is selected via the configuration software.
                                                                                                         –   Ready for connection of induction loop systems, which enable
                                                                                                             persons wearing hearing aids with an induction loop to receive
     Applications for the hybrid modules are all kinds of call and emergency
                                                                                                              Intercom audio signals in clear, uninterrupted quality
     call stations, where the stations are built-in and only the external call but-
     tons are used. This means, special solutions for e.g. emergency call pil-
     lars, elevator cabins, ticketing machines or barriers at entrances and exits
     can be created, which optimally satisfy function and optical appearance
     of the customer specifications.
     Furthermore, the hybrid modules are perfectly suited for use as door sta-
     tions at entrance areas and gateways due to two integrated relay outputs.
ET 908H DATA SHEET V1.6/0722                                                                                                       SA | 1           commend.com
The design and/or specifications of products may be subject to change for improvement without prior notice. Errors excepted.
                                                                                                                                          Security and Communication
                                                                                                       Passion for Audio
                                                                                                                         by Commend
                                                                       Ultimate speech intelligibility in any situation
                                                                       OpenDuplex® with HD voice and enhanced HD Voice by Commend enables natural,
                                                                       hands-free talking and listening – as crystal clear and natural as a face-to-face
                                                                       conversation.
                                                  IVC
            Natural                             Intelligent Volume                              High                                Background noise                    Loudspeaker/microphone
         communication                                 Control                                 volume                                 suppression                             surveillance
 Audio // Basics                                                                                          Audio // Functions                                                              IoIP SIP
                           Enhanced HD Voice by Commend transfers the au-                                 Dynamic background noise suppression virtually
 eHD Voice
                           dio signal at a bandwidth of 16 kHz, thus capturing                            eliminates all ambient noise
 (IoIP)
                           the entire frequency spectrum of the human voice.
                                                                                                          Loudspeaker-microphone surveillance – ensures the
 HD Voice                  HD Voice by Commend transfers the audio signal at                              availability of the Intercom station while reducing the
 (SIP)                     a bandwidth of 7 kHz                                                           need for manual verification of its functionality
 Amplifier                 Highly efficient class-D amplifier with 10 W                                   Audio monitoring – fully automated emergency calls trig
                                                                                                          gered by defined noise levels for more security
                                                                                                          Peer-to-peer audio – reduces network and server load to
Learn more                                                                                                ensure efficient use of resources
audio.commend.com                                                                                         Audio recording and lip synchronous audio/video record-
                                                                                                          ing of conversations for documentation and evidence                                            1)
                                                                                                          keeping purposes
                                                                                                          Conference call function for simultaneous talking with
                                                                                                          multiple conversation partners
                                                                                                          Speech activity detection senses when calls are
                                                                                                          finished (no microphone signal) and terminates the con-
                                                                                                          nection automatically
                                                                                                          Simplex mode for applications requiring controlled
                                                                                                          communication – e.g. for security solutions based on the
                                                                                                          “push-to-talk/release-to-listen” method
                                                                                                          OpenDuplex® for natural, hands-free communication
                                                                                                          IVC (Intelligent Volume Control) automatically adjusts the
                                                                                                          device’s volume setting to the ambient noise level
                                                                                                          Public address functions                                                                       2)
                                                                                                          1)   Audio recording option on a compatible VMS via ONVIF Profile S.
                                                                                                          2)   Public address functions via multicast or ONVIF Profile S announcements from a compatible VMS.
ET 908H DATA SHEET V1.6/0722                                                                                                             SA | 2                  commend.com
The design and/or specifications of products may be subject to change for improvement without prior notice. Errors excepted.
                                                                                                                                      Security and Communication
ET 908H
Technical specifications
Technical data
 Microphone input:                        possibility for connection of an electret condenser
                                                        microphone or a dynamic microphone
                                         electret condenser microphone: nominal −43 dB/Pa
                                                             (feeding voltage: 2.5 V at 3.3 kΩ)
 Loudspeaker output:                                                 10 W at 4 Ω/6 W at 8 Ω              Line length in LAN
                                                             max. 6.3 Veff (volume level “11”)
                                                                                                         The maximum line length of Cat. 5 cabling in a LAN is 100 m (328 ft) – e.g.
 Ext. microphone, loudspeaker:           possibility for connection of e.g. a headset/handset            from switch to ET 908H.
                                    EP output: max. 880 mVeff (volume level “11”) , Ri = 200 Ω
                                                    EM input, nominal level: 14 mV on 3.3 kΩ
                                                                       (feeding voltage 2.5 V)
 Call button:                       possibility for connection of 3 single buttons or a keypad           Extent of supply
 External LED:                                      possibility for connection of an RGB-LED             –     Hybrid module
 Inputs:                                                         3 inputs for floating contacts          –     Mounting kit (4 fixing spacers with M3 thread, red LED)
                                                            (IoIP: detection of 5 input states)          –     MIC 480 (ET 908HMI and ET 908HMI-1 only)
 Outputs:                                             2 relay outputs (switch-over contacts)             –     Claiming code
                                                                max. 60 W (DC)/37.5 VA (AC)              –     Open source compliance information
                                                                                      max. 2 A
                                                                        max. 60 VDC/30 VAC               –     Short reference
                                                    expected life: min. 5 x 104 (2 A), 105 (1 A)
 Line input:                               for feed-in of audio (e.g. music, radio conference)
                                                      nominal level: 0 dBu (0.775 V) at 10 kΩ            System requirements
 IoIP audio bandwidth:                                                                  16 kHz
                                                                                                         IoIP
 SIP audio bandwidth:                                                                     7 kHz
                                                                                                         Intercom Server
 Operating temperature range:                            −40 °C to +70 °C (−40 °F to +158 °F)            – GE 800 (min. PRO 800 6.3) with G8-IP (min. version 6.6A) or
 Storage temperature range:                              −40 °C to +70 °C (−40 °F to +158 °F)            –     GE 300 (min. PRO 800 6.3) with G3-IP (min. version 6.6A) or
 Relative humidity:                                               up to 95%, not condensing              –     IS 300/G8-IP-32 (min. PRO 800 6.3, min. version 6.6A) or
 Connection:                                                            spring clamp terminals           –     S3/S6/VirtuoSIS (min. version 7.1)
                                                     (conductor cross-section: 0.2 – 1.5 mm2)            Configuration software
                                                           expansion plug, e.g. for EB2E2AHE             – CCT 800 (min. version 7.1)
                                                        IP uplink: shielded RJ45 modular jack            –     IP Station Config (included in setup of CCT 800)
                                                    IP downlink: shielded RJ45 modular jack
 Power supply:                                      DC power supply: 24 VDC (15 – 28 VDC),
                                                                                                         SIP
                                                    max. 1.0 A @ 15 V, max. 0.54 A @ 28 V
                                            PoE (Power over Ethernet): IEEE 802.3af/Class 0,             –     S3/S6/VirtuoSIS (min. version 7.1) or
                                                                         IEEE 802.3at/Type 1             –     Compatible SIP server (see compatibility list “Interoperability SIP”) or
 Power consumption                                                     idle 2.6 W, max. 15 W             –     Serverless operation
                                                                 (depending on configuration)
 Device class:                                               ES1, PS2 as per IEC/EN 62368-1              Device firmware
 Network cabling:                                                         min. shielded Cat. 5           –     IoIP-Device (min. version 7.2)
 Protocols (IoIP):                            IPv4, UDP, DHCP, RTP, RTCP, SNMPv2c, SNTPv4                –     SIP Series (min. version 3.8.1, build 61)
 Protocols (SIP):                           IPv6, IPv4, TCP, UDP, HTTP (RFC 2617, RFC 3310),
                                                                                                         ATTENTION
                                              RTP (RFC 3550), TLS, SRTP, RTCP, DHCP, STUN,
                                             TFTP, SDP (RFC 2327), SIP (RFC 3261), SNMPv2,               Downgrading to firmware version SIP Series 3.9 build 24 or lower is not
                                                  URI (RFC 2396), DTMF Decoding (RFC 2876,               supported.
                                                  RFC 2833), SIP User Agent (UDP RFC 3261),
                                                                SIP Refer Method (RFC 3515)
 Codecs (SIP):                                             G.711 a-Law, G.711 μ-Law, G.722
 Data rate:                                  2 x 10/100 MBit/s (Full/Half Duplex) auto MDIX
 Dimensions (W x H x D):                   ET 908H: 65 x 130 x 18 mm (2.56 x 5.12 x 0.71 in)
                                         ET 908H-1: 65 x 130 x 22 mm (2.56 x 5.12 x 0.87 in)
 Weight:                                                              approx. 170 g (0.37 lbs)
ET 908H DATA SHEET V1.6/0722                                                                                                        TE | 1             commend.com
The design and/or specifications of products may be subject to change for improvement without prior notice. Errors excepted.
                                                                                                                               Security and Communication
Requirements to the network for use as SIP device
Ports
–   The configuration via the web interface is done via TCP port 80 (cannot be configured).
–   The communication from the SIP device to the SIP server is done via the following ports (both are configurable):
     –    SIP: UDP port 5060
     –    RTP: UDP port 16384 (incoming)
Requirements to the network for use as IoIP device
IP addresses and ports
–   For the ET 908H, the DHCP functionality is available. If DHCP is not used, the ET 908H must have a fixed IP address.
–   In case of a changing public IP address, dynamic registration of an ET 908H is possible.
–   Communication from the program IP Station Config is done via port 16399 (cannot be configured).
–   Communication from the ET 908H to the Intercom Server (UDP protocol) is done via port 16400 (configurable).
QoS requirements
–   One-way delay max. 100 ms
–   Delay jitter max. 50 ms
–   0% packet loss for perfect audio quality
Bandwidth
For further information on bandwidth, see guideline “IoIP Technology“.
ET 908H DATA SHEET V1.6/0722                                                                                                   TE | 2   commend.com
The design and/or specifications of products may be subject to change for improvement without prior notice. Errors excepted.
                                                                                                                                     Security and Communication
ET 908H
Installation instructions                                                                                  Safety instructions
                                                                                                           –   This device shall be installed or replaced by trained and qualified personnel
                                                                                                               only.
                                                                                                           –   Conductive housing and mounting plates must be connected to protective
                                                                                                               earth.
Dimensions                                                                                                 –   Before using this device, ensure all cables are connected correctly and are
                                                                                                               not damaged.
Measuring units in mm (in), not to scale!
                                                                                                           –   Disconnect the DC power and all Ethernet cables for any maintenance of
                                                                                                               the device.
                             ET 908H
                                                                         15 (0.59)                         –   Allow the device to cool down completely before touching any parts.
                                                                                       18 (0.71)           –   Install or store this device out of the reach of children and do not allow
                                                                                                               persons unfamiliar with the device and these instructions to handle and
                                                                                                               operate the device.
             8 (0.31)
                                                                                                           –   All connected circuits shall fulfil the following requirements:
                                                                                                                –   Safety Extra Low Voltage (SELV) and Limited Power Source (LPS) ac-
                             ET 908H-1                                                                              cording to IEC/EN 60950-1 or
                                                                                                                –   ES1, PS2 circuits and Annex Q (Limited Power Source) according to
                                                                                                                    IEC/EN/UL 62368-1
                                                                         18.5 (0.73)
                                                                                       21.5 (0.85)
                                                                                                           –   All changes or modifications not expressly approved by the party
                                                                                                               responsible for compliance could void the user’s authority to operate the
                                                                                                                equipment.
             8 (0.31)
                                                                                                           Mounting instructions
                                                                                                           –   The device must be protected against dust, dirt, humidity and eventual
                                                                                                               environmental influences. The housing must protect against ES1/PS2
                 25 (0.99)
                                                                                                               circuits .
                                                                                               35 (1.38)
                                                                                                           –   Use shielded Ethernet cables only.
                                                                                                           –   Ensure a minimum distance of 8 mm (0.31 in) to the housing or mount-
                                                                                                               ing plate (e.g. using spacer pins included in the extent of supply).
                                                                                                           –   The max. diameter for spacer pins is 9.1 mm (0.36 in) for plastic and 5.6
                                                                                                               mm (0.22 in) for conductive materials.
                                                                                                           –   This equipment has been tested and found to comply with the limits for
                                                                                                               a Class A digital device, pursuant to part 15 of the FCC rules. These limits
                                                                                                               are designed to provide reasonable protection against harmful interfer-
                                                                                                               ence when the equipment is operated in a commercial environment. This
                                                                                                               equipment generates, uses and can radiate radio frequency energy and,
                                                                                                               if not installed and used in accordance with the instruction manual, may
130 (5.12)
                 80 (3.15)
                                                                                              60 (2.36)
                                                                                                               cause harmful interference to radio communications. Operation of this
                                                                                                               equipment in a residential area is likely to cause harmful interference in
                                                                                                               which case the user will be required to correct the interference at his
                                                                                                               own expense.
                                       ø3,2 (4x)
                                       (0.13)
                                                               ø4 (4x)
                                                               (0.16)
                                                   55 (2.17)                       5
                                                   65 (2.56)                     (0.2)
ET 908H DATA SHEET V1.6/0722                                                                                                         IN | 1             commend.com
The design and/or specifications of products may be subject to change for improvement without prior notice. Errors excepted.
                                                                                                                                       Security and Communication
Connection
NOTE
The connection diagram to the left shows a hybrid module with RJ45 jacks mounted vertically (ET 908H-1).
                          Loudspeaker (4 or 8 Ω)
                                         Microphone
                             Handset:
                                         Loudspeaker
                                Inputs       Buttons
                                                         LINE IN+
                                                         LINE IN–
                                                         MIC+
                                                         MIC–
                            GND
                            GND
                                                         EM+
                                                         EM–
                                                         EP+
                                                         LS+
                                                         EP–
                                                         LS–
                            IN3
                            IN2
                            IN1
                                                  T
                                                  0
                                                                                                         Connection keyboard
                                                                                                         Up to 3 buttons at the terminals “T”, “0” and “X” or a keypad at the keypad-
                                                                                                         pin plug (10 pins, distance 2.54 mm/0.1 in).
       Keypad
(see keypad matrices)
                             R5
                             R1
                             R2
                             R3
                             R4
                             C1
                             C2
                             C3
                             C4
                             C5
                                                                                                         Reset ET 908H / ET 908HMI (SIP)
                                                                                                         During startup, connect the contacts “GND”, “T” and “X” (short circuit) until
     Expansion jack                                                                                      the red LED connected to “LEDR+” and “LEDR–” starts blinking. The hybrid
    (e.g. EB2E2AHE)                                                                                      module is reset.
                                                                                                  +5V         5V         JST jack
                                                                         LED+
                                                                                                              R    470 Ω internal series
                                                                         LEDR                                 G    470 Ω
                                                                         LEDG                    R/G/B        B    150 Ω resistors
                                                                         LEDB                              for external LEDs
                NC
           OUT2 COM
                NO
                                                          IP uplink        IP downlink
                                         LEDR+
                                         LEDR–
                             COM
                                          DC+
                                                        (LAN + PoE)           (LAN)
                                          DC
                             NO
                             NC
                              OUT1 15-28V
–   PoE has to be connected to the RJ45 jack “IP uplink”.
–   Further IP devices can be connected to the RJ45 jack “IP downlink”, e.g. an IP camera.
–   Due to the switch function, up to 20 ET 908H can be linked in series (or other IP devices, e.g. PC).
ATTENTION
If multiple ET 908H are connected in series, only the first device can be supplied with Power over Ethernet.
All other devices (connected in series) must be supplied separately by an external power supply unit or PoE injector.
ET 908H DATA SHEET V1.6/0722                                                                                                           IN | 2      commend.com
The design and/or specifications of products may be subject to change for improvement without prior notice. Errors excepted.
                                                                                                                                 Security and Communication
Keypad matrices
            IoIP                                                                 SIP – “Enable Full Keypad“                                   SIP – “Function Buttons“
               R1 R2 R3 R4 C1 C2 C3 C4 C5                                           R1 R2 R3 R4 C1 C2 C3 C4 C5                                   R1 R2 R3 R4 C1 C2 C3 C4 C5
Quality tested. Reliable. Smart.                                                                         A strong worldwide network
COMMEND products are developed and manufactured                                       OBS                COMMEND is represented all over the world by local Commend Partners and
by Commend International in Salzburg, Austria.                                       ESSIVE             helps to improve security and communication with tailored Intercom solutions.
                                                                                      ABOUT
The development and manufacturing processes are                                       QUAL
                                                                                      ITY                www.commend.com
certified in accordance with EN ISO 9001:2015.
The technical data contained herein has been provided solely for informational
purposes and is not legally binding. Subject to change, technical or otherwise.
IoIP®, OpenDuplex® and Commend® are trademarks registered by Commend
International GmbH. All other brands or product names are trademarks or
registered trademarks of the respective owner and have not been specifically
earmarked.
ET 908H DATA SHEET V1.6/0722                                                                                                     IN | 3            commend.com
The design and/or specifications of products may be subject to change for improvement without prior notice. Errors excepted.