0% found this document useful (0 votes)
61 views14 pages

Dryer Ducting Status

The document provides an inventory list of dryer ducting items with their sizes and quantities. It also includes a status report from the contractor on the progress of each item, noting that many items are cut into pieces but not yet finished or ready.

Uploaded by

Monty Kushwaha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views14 pages

Dryer Ducting Status

The document provides an inventory list of dryer ducting items with their sizes and quantities. It also includes a status report from the contractor on the progress of each item, noting that many items are cut into pieces but not yet finished or ready.

Uploaded by

Monty Kushwaha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 14

Dryer Ducting Status on 10.08.

2023_ Contractor - Irshad


S.No. Iteam Name Size Qty
1 Air Dispersor 5230 x 4332 MM 01 No
2 Flat Of Air Dispersor 50 x 10 MM (6.0 M Long) 01 No
4 Atomizer Tray Resting Flange Ø 1405 - OD, Ø 1305 - ID 01 No
5 Main Air Filter Frame 3200 x 2560 MM 01 No
Hopper 3200 x 2560 MM (Ø 900) 01 No
7 (1500 + 500)Long
Bend With Reducer From Air
Ø 900, Ø 809 01 No
8 Filter Housing To S. Fan Suction
9 Flange Of S.fan Section Bend Ø 1002-OD, Ø 902-ID 01 No
Duct From S.Fan Outlet To 2238 x 1838 MM , 630 x 01 No
11 Steam Radiator 800 (1700)Long
Duct From Main Radiator To Air 2238 x 1838 MM , 599 x 01 No
12 Disperser 2399 (3720)Long
Square To Round Reducer 900 x 800, Ø 1100
01 No
14 ( Dryer To Cyclone) (1100) long
15 Dryer To Cyclone Duct Ø 1100 - OD, 6.0 M Long 01 No
Dryer To Cyclone ( Flange With Ø 1202-OD, Ø 1102-ID 02 Nos
16 Nut & Bolt
18 "Y" Duct ( Cyclone To Exhaust) 01 Nos
Flange With Nut Bolt (Cyclone To 1002 x 1002 mm 01 No
19 Exhaut Fan)
Square To Round Reducer 900 x 800 mm Ø 1100
01 No
21 ( Cyclone To Exhaust Fan) mm (900 mm) long
Duct ( Main Cyclone To Exhaust Ø 1000 mm, Ø905 mm
01 No
22 Fan) 1500 mm Long
Man Way With Cover & Nut -
Ø 900 01 No
23 Bolt (Dryer To Cyclone Duct)
FBD Supply Fan Filter Housing
1280 x 1280 mm 01 No
25 Frame
FBD Supply Fan Filter Housing 1280 x 1280 mm, Ø 253
01 No
26 Hopper mm (600 +500 mm ) long
FBD Supply Fan To FBD 898 x 608 mm, 190 x 250
01 No
28 Dehumidifier Hopper mm (950 mm ) long
FBD Air Dehumidifier To FBD
Ø 450 01 No
29 Inlet (Bend)
FBD Air Dehumidifier To FBD 898 x 608 mm Ø 405 mm
01 No
30 Inlet (Hopper) (620 mm) long
FBD Air Dehumidifier To FBD Ø 450 mm (3500 mm
01 No
32 Inlet (Duct) Long)
FBD Air Dehumidifier To FBD
Ø 552 - od , Ø 452 01 No
33 Inlet (Flange Nut Bolt)
FBD Air Supply Fan To FBD Air 698 x 533 mm, 250 x 190
01 No
35 Heater Hopper mm (650 mm ) long
FBD Air Heater To FBD Inlet 698 x 533 mm, Ø 400 (650
01 No
36 Hopper mm ) long
FBD Air Heater To FBD Inlet
Ø 400 03 Nos
37 Bend
FBD Air Heater To FBD Inlet
Ø 400 (4.0 M) Long 01 No
39 Duct
Power Shifter TO Ground Floor
Ø 250mm (4.8 M) Long 01 No
40 (Duct)
Rectangular Reducer ( FBD Ø 400, 315 x 400 mm (500
01 No
42 Exhaust Fan Chimney) mm ) long
Duct ( FBD Exhaust Fan
Ø 400 (15.8 M) Long 01 No
43 Chimney)
Flange With Nut Bolt ( FBD
Ø 502 - OD, Ø 402 - ID 01 No
44 Exhaust Fan Chimney)
46 Frame For FBD Fan Room 2560 x 1280 mm 01 No
47 Frame For Supply Fan Room 3200 x 2560 mm 01 No
Man Hole Before & After
550 x 550 mm 02 Nos
49 Radiator
Chimney Duct With Top Cover
Ø 950 - OD, 14 M Long 01 No
50 Exhaust Fan
51 Chimney Reducer Exhaust Fan Ø 950, 710 x 898 mm 01 No
53 Flange With Nut & Bolt Ø 1052 OD, Ø 952 ID 01 No
Recovery Room Chimney Duct
Ø 950 - OD, 6.25 M Long 03 Nos
54 Exhaust Fan
56 FBD TO FBD Cyclone (Bend) Ø 500 01 No
Rectangular Reducer ( FBD To Ø 500, 500 x 500 mm (500
01 No
57 FBD Cyclone) mm ) long
Flange With Nut Bolt ( FBD To
Ø 602 OD, Ø 502 ID 01 No
58 FBD Cyclone)
Ø 700, Ø 500 (445 mm
Reducer ( FBD To FBD Cyclone) 01 No
60 Long)
61 Duct ( FBD To FBD Cyclone) Ø 500, 6.0 M Long 01 No
62 Wing insert
63 Dryer gate
64 Concentrate vat
65 CIP Water Tank
66 water circulation tank
atus on 10.08.2023_ Contractor - Irshad
Status Remaks
Material available but duct not ready
Material available
Not Ready
Not Ready Material avail.

ss 304 2 mm sheet not avail. So not ready

only duct ready in shell form Not finished


Flange not ready

material cutted in pices Not finished

Material cutted in Pices Not finished

Material cutted in pices Not finished


shell welding done Not finished

Not Ready
Material cutted in pices Not finished

Frame Ready without hole Not finished

Material cutted in pices Not finished

only duct ready in shell form Not finished

Not Ready

Material cutted in pices Not finished

Material cutted in pices

Material cutted in pices Not finished

shell rolled welding done Not finished

Material not cutted

shell rolled welding done Not finished

shell rolled welding done Not finished

Material cutted in pices Not finished

Material cutted in pices duct rolled Not finished


shell rolled welding done Not finished

shell rolled welding done Not finished

Shell rolling done joint under finishing Not finished

Material cutted in pices Not finished

shell rolled under tacking Not finished

Not Ready
Not Ready
Not Ready

Not Ready

shell rolled only Not finished


shell rolled only Not finished
Not Ready

shell rolled Not finished


shell rolled Not finished

Material cutted in pices Not finished

Not Ready

Shell rolled only Not finished


shell rolled only Not finished
Not available
only side support angle cuttng done
only shell rolled , under joint finishing
work not started yet
work not started yet
Dryer Ducting Status on 19.10.2023_ Contractor - Nadeem
S.No. Iteam Name Size Qty
1 Air Dispersor 5230 x 4332 MM 01 No
2 Flat Of Air Dispersor 50 x 10 MM (6.0 M Long) 01 No
3 Atomizer Tray Resting Flange Ø 1405 - OD, Ø 1305 - ID 01 No
4 Main Air Filter Frame 3200 x 2560 MM 01 No
Hopper 3200 x 2560 MM (Ø 900) 01 No
5 (1500 + 500)Long
Bend With Reducer From Air
Ø 900, Ø 809 01 No
6 Filter Housing To S. Fan Suction
7 Flange Of S.fan Section Bend Ø 1002-OD, Ø 902-ID 01 No
Duct From S.Fan Outlet To 2238 x 1838 MM , 630 x 01 No
8 Steam Radiator 800 (1700)Long
Duct From Main Radiator To Air 2238 x 1838 MM , 599 x 01 No
9 Disperser 2399 (3720)Long
Square To Round Reducer 900 x 800, Ø 1100
01 No
10 ( Dryer To Cyclone) (1100) long
11 Dryer To Cyclone Duct Ø 1100 - OD, 6.0 M Long 01 No
Dryer To Cyclone ( Flange With Ø 1202-OD, Ø 1102-ID 02 Nos
12 Nut & Bolt
13 "Y" Duct ( Cyclone To Exhaust) 01 Nos
Flange With Nut Bolt (Cyclone To 1002 x 1002 mm 01 No
14 Exhaut Fan)
Square To Round Reducer 900 x 800 mm Ø 1100
01 No
15 ( Cyclone To Exhaust Fan) mm (900 mm) long
Duct ( Main Cyclone To Exhaust Ø 1000 mm, Ø905 mm
01 No
16 Fan) 1500 mm Long
Man Way With Cover & Nut -
Ø 900 01 No
17 Bolt (Dryer To Cyclone Duct)
FBD Supply Fan Filter Housing
1280 x 1280 mm 01 No
18 Frame
FBD Supply Fan Filter Housing 1280 x 1280 mm, Ø 253
01 No
19 Hopper mm (600 +500 mm ) long
FBD Supply Fan To FBD 898 x 608 mm, 190 x 250
01 No
20 Dehumidifier Hopper mm (950 mm ) long
FBD Air Dehumidifier To FBD
Ø 450 01 No
21 Inlet (Bend)
FBD Air Dehumidifier To FBD 898 x 608 mm Ø 405 mm
01 No
22 Inlet (Hopper) (620 mm) long
FBD Air Dehumidifier To FBD Ø 450 mm (3500 mm
01 No
23 Inlet (Duct) Long)
FBD Air Dehumidifier To FBD
Ø 552 - od , Ø 452 06 No
24 Inlet (Flange Nut Bolt)
FBD Air Supply Fan To FBD Air 698 x 533 mm, 250 x 190
01 No
25 Heater Hopper mm (650 mm ) long
FBD Air Heater To FBD Inlet 698 x 533 mm, Ø 400 (650
01 No
26 Hopper mm ) long
FBD Air Heater To FBD Inlet
Ø 400 03 Nos
27 Bend
FBD Air Heater To FBD Inlet
Ø 400 (4.0 M) Long 01 No
28 Duct
Power Shifter TO Ground Floor
Ø 250mm (4.8 M) Long 01 No
29 (Duct)
Rectangular Reducer ( FBD Ø 400, 315 x 400 mm (500
01 No
30 Exhaust Fan Chimney) mm ) long
Duct ( FBD Exhaust Fan
Ø 400 (15.8 M) Long 01 No
31 Chimney)
Flange With Nut Bolt ( FBD
Ø 502 - OD, Ø 402 - ID 06 No
32 Exhaust Fan Chimney)
33 Frame For FBD Fan Room 2560 x 1280 mm 01 No
34 Frame For Supply Fan Room 3200 x 2560 mm 01 No
Man Hole Before & After
550 x 550 mm 02 Nos
35 Radiator
Chimney Duct With Top Cover
Ø 950 - OD, 14 M Long 01 No
36 Exhaust Fan
37 Chimney Reducer Exhaust Fan Ø 950, 710 x 898 mm 01 No
38 Flange With Nut & Bolt Ø 1052 OD, Ø 952 ID 01 No
Recovery Room Chimney Duct
Ø 950 - OD, .625 M Long 03 Nos
39 Exhaust Fan
40 FBD TO FBD Cyclone (Bend) Ø 500 01 No
Rectangular Reducer ( FBD To Ø 500, 500 x 500 mm (500
01 No
41 FBD Cyclone) mm ) long
Flange With Nut Bolt ( FBD To
Ø 602 OD, Ø 502 ID 06 No
42 FBD Cyclone)
Ø 700, Ø 500 (445 mm
Reducer ( FBD To FBD Cyclone) 01 No
43 Long)
44 Duct ( FBD To FBD Cyclone) Ø 500, 6.0 M Long 01 No
45 Wing insert
46 Dryer gate
47 CIP Water Tank

CYCLONE TO EXHAUST FAN 1102 1002 2


tus on 19.10.2023_ Contractor - Nadeem
Status Remaks
on site
on site
ready laying at factory
loose Material avail.

ready according to nadeem (on site)

ready laying at factory


flange forging done

loose dispatched on dt 10.10.2023

Loose (6 sheets ) dispatched on dt 10.10.2023

loose dispatched on dt 10.10.2023


ready (3 shells laying in factory) 2 Shell dispatch on 12.10.2023

flange forging done


Loose dispatched on dt 10.10.2023

ready dispatched on dt 12.10.2023

loose dispatched on dt 10.10.2023

ready dispatched on 12.10.2023

Not Ready

Material cutted in pices Not finished

Loose dispatched on dt 10.10.2023

ready dispatched on dt 10.10.2023

ready dispatched on dt 12.10.2023

Loose dispatched on dt 10.10.2023

ready dispatched on dt 10.10.2023

flange forging done Not finished

ready dispatched on dt 10.10.2023

Loose dispatched on dt 10.10.2023


ready dispatched on dt 12.10.2023

ready dispatched on dt 10.10.2023

ready dispatched on dt 10.10.2023

Loose dispatched on dt 10.10.2023

ready dispatched on dt 10.10.2023

flange forging done


Not Ready
Not Ready

flange and lid ready rest fabrication on site Laying at factory

READY (7 shells) Not finished


Loose dispatched on dt 10.10.2023
flange forging done

ready dispatch on 12.10.2023


ready dispatched on dt 12.10.2023

Loose dispatched on dt 10.10.2023

flange forging done

ready laying at factory


ready dispatched on dt 12.10.2023
Not started
80% COMPLETE FINISHING RAMAINING
work not started yet
Dryer Ducting Status on 27.10.2023_ Contractor - Nadeem
S.No. Iteam Name Size Qty
1 Air Dispersor 5230 x 4332 MM 01 No
2 Flat Of Air Dispersor 50 x 10 MM (6.0 M Long) 01 No
3 Atomizer Tray Resting Flange Ø 1405 - OD, Ø 1305 - ID 01 No
4 Main Air Filter Frame 3200 x 2560 MM 01 No
3200 x 2560 MM (Ø 900)
5 Hopper 01 No
(1500 + 500)Long
Bend With Reducer From Air Filter
6 Ø 900, Ø 809 01 No
Housing To S. Fan Suction
7 Flange Of S.fan Section Bend Ø 1002-OD, Ø 902-ID 01 No
Duct From S.Fan Outlet To Steam 2238 x 1838 MM , 630 x
8 01 No
Radiator 800 (1700)Long
Duct From Main Radiator To Air 2238 x 1838 MM , 599 x
9 01 No
Disperser 2399 (3720)Long
Square To Round Reducer ( Dryer 900 x 800, Ø 1100
10 01 No
To Cyclone) (1100) long
11 Dryer To Cyclone Duct Ø 1100 - OD, 6.0 M Long 01 No
Dryer To Cyclone ( Flange With Nut
12 Ø 1202-OD, Ø 1102-ID 02 Nos
& Bolt

13 "Y" Duct ( Cyclone To Exhaust) 01 Nos

Flange With Nut Bolt (Cyclone To


14 1002 x 1002 mm 01 No
Exhaut Fan)
Square To Round Reducer 900 x 800 mm Ø 1100
15 01 No
( Cyclone To Exhaust Fan) mm (900 mm) long
Duct ( Main Cyclone To Exhaust Ø 1000 mm, Ø905 mm
16 01 No
Fan) 1500 mm Long
Man Way With Cover & Nut - Bolt
17 Ø 900 01 No
(Dryer To Cyclone Duct)
FBD Supply Fan Filter Housing
18 1280 x 1280 mm 01 No
Frame
FBD Supply Fan Filter Housing 1280 x 1280 mm, Ø 253
19 01 No
Hopper mm (600 +500 mm ) long
FBD Supply Fan To FBD 898 x 608 mm, 190 x 250
20 01 No
Dehumidifier Hopper mm (950 mm ) long
FBD Air Dehumidifier To FBD Inlet
21 Ø 450 01 No
(Bend)
FBD Air Dehumidifier To FBD Inlet 898 x 608 mm Ø 405 mm
22 01 No
(Hopper) (620 mm) long
FBD Air Dehumidifier To FBD Inlet Ø 450 mm (3500 mm
23 01 No
(Duct) Long)
FBD Air Dehumidifier To FBD Inlet
24 Ø 552 - od , Ø 452 06 No
(Flange Nut Bolt)
FBD Air Supply Fan To FBD Air 698 x 533 mm, 250 x 190
25 01 No
Heater Hopper mm (650 mm ) long
FBD Air Heater To FBD Inlet 698 x 533 mm, Ø 400
26 01 No
Hopper (650 mm ) long
27 FBD Air Heater To FBD Inlet Bend Ø 400 03 Nos
28 FBD Air Heater To FBD Inlet Duct Ø 400 (4.0 M) Long 01 No
Power Shifter TO Ground Floor
29 Ø 250mm (4.8 M) Long 01 No
(Duct)
Rectangular Reducer ( FBD Ø 400, 315 x 400 mm
30 01 No
Exhaust Fan Chimney) (500 mm ) long
31 Duct ( FBD Exhaust Fan Chimney) Ø 400 (15.8 M) Long 01 No
Flange With Nut Bolt ( FBD Exhaust
32 Ø 502 - OD, Ø 402 - ID 06 No
Fan Chimney)
33 Frame For FBD Fan Room 2560 x 1280 mm 01 No
34 Frame For Supply Fan Room 3200 x 2560 mm 01 No
35 Man Hole Before & After Radiator 550 x 550 mm 02 Nos

Chimney Duct With Top Cover


36 Ø 950 - OD, 14 M Long 01 No
Exhaust Fan
37 Chimney Reducer Exhaust Fan Ø 950, 710 x 898 mm 01 No
38 Flange With Nut & Bolt Ø 1052 OD, Ø 952 ID 01 No
Recovery Room Chimney Duct
39 Ø 950 - OD, .625 M Long 03 Nos
Exhaust Fan
40 FBD TO FBD Cyclone (Bend) Ø 500 01 No
Rectangular Reducer ( FBD To FBD Ø 500, 500 x 500 mm
41 01 No
Cyclone) (500 mm ) long
Flange With Nut Bolt ( FBD To FBD
42 Ø 602 OD, Ø 502 ID 06 No
Cyclone)
Ø 700, Ø 500 (445 mm
43 Reducer ( FBD To FBD Cyclone) 01 No
Long)
44 Duct ( FBD To FBD Cyclone) Ø 500, 6.0 M Long 01 No
45 Wing insert
46 Dryer gate
47 CIP Water Tank
Flange With Nut Bolt ( cyclone to
48 Ø 1102 OD, Ø1002 ID 02 No
exhaust fan)

DRYER DUCT FLANGE STATUS DATE : 28-10-2023


S.No. Iteam Name Size Qty
1 Flange Of S.fan Section Bend Ø 1002-OD, Ø 902-ID 01 pair
Dryer To Cyclone ( Flange With Nut
2 Ø 1202-OD, Ø 1102-ID 02 pair
& Bolt
FBD Air Dehumidifier To FBD Inlet
3 Ø 552 - od , Ø 452 06 pair
(Flange Nut Bolt)
Flange With Nut Bolt ( FBD Exhaust
4 Ø 502 - OD, Ø 402 - ID 06 pair
Fan Chimney)
Flange With Nut & Bolt ( chimney
5 Ø 1052 OD, Ø 952 ID 01 pair
outlet)
Flange With Nut Bolt ( FBD To FBD
6 Ø 602 OD, Ø 502 ID 06 pair
Cyclone)
Flange With Nut Bolt ( cyclone to
7 Ø 1102 OD, Ø1002 ID 01 pair
exhaust fan)
Man Way With Cover & Nut - Bolt
8 Ø 900 01 No
(Dryer To Cyclone Duct)
s on 27.10.2023_ Contractor - Nadeem
Status Remaks
on site
on site
ready laying at factory
loose Material avail.
ready according to nadeem (on site)

ready laying at factory


flange forging done
loose dispatched on dt 10.10.2023

Loose (6 sheets ) dispatched on dt 10.10.2023

loose dispatched on dt 10.10.2023


ready (3 shells laying in factory) 2 Shell dispatch on 12.10.2023
Drillling in progress

Loose dispatched on dt 10.10.2023

ready dispatched on dt 12.10.2023

loose dispatched on dt 10.10.2023

ready dispatched on 12.10.2023

Not Ready

loose dispatched on dt 12.10.2023

Loose dispatched on dt 10.10.2023

ready dispatched on dt 10.10.2023

ready dispatched on dt 12.10.2023

Loose dispatched on dt 10.10.2023

ready dispatched on dt 10.10.2023

flange forging done Not finished

ready dispatched on dt 10.10.2023


Loose dispatched on dt 10.10.2023
ready dispatched on dt 12.10.2023
ready dispatched on dt 10.10.2023
ready dispatched on dt 10.10.2023

Loose dispatched on dt 10.10.2023


ready dispatched on dt 10.10.2023
flange forging done ( 4 pair) 2 pair remaining
Not Ready
Not Ready
flange and lid ready rest fabrication on site Laying at factory

READY (10 shells ready ) 2 shell dispatch on 12.10.2023


Loose dispatched on dt 10.10.2023
flange forging done
ready dispatch on 12.10.2023
ready dispatched on dt 12.10.2023
Loose dispatched on dt 10.10.2023

flange forging remaining

ready laying at factory


ready dispatched on dt 12.10.2023
Not started
hinge drilling and final finishing
90% COMPLETE
remaining
work not started yet
flange forging done

NGE STATUS DATE : 28-10-2023


Status Remaks
flange forging done
Drillling done

flange forging done (6 PAIR)

flange forging done ( 4 pair) 2 pair remaining

flange forging done

forging not started

machining done

material specifications not available in


drawing.