Section 1
Section 1
SECTION 1 Ex LIGHTING
GL4M Exd Mercury vapour well glass Zone 1 and 2 1-6 to 1-7
GL4H Exd Metal halide well glass Zone 1 and 2 1-6 to 1-7
GL3M Exn/D.I.P. Mercury vapour well glass Zone 2, 21 and 22 1-8 to 1-9
GL3H Exn/D.I.P. Metal halide well glass Zone 2, 21 and 22 1-8 to 1-9
GL9M Exn Stainless steel mercury vapour fixture Zone 2 1-10 to 1-11
GL9H Exn Stainless steel metal halide fixture Zone 2 1-10 to 1-11
1-1
SECTION 1 Ex LIGHTING
Features
The GL4 series luminaire is a high intensity discharge (H.I.D.) well glass
fitting suitable for hazardous area Group II Zone 1 & 2. It can be fitted with lamps
up to 400 watt high pressure Sodium, Mer cury Vapour and Metal Halide
Integral control gear
Stainless steel hardware
Hinged cover allows ease for servicing and relamping
One piece silicon gasket for water tight seals
Variety of mounting arrangements
Choice of reflectors in polyester and aluminium
Stanchion mounting bracket allows 10 to 150˚ rotation in vertical plane for setting
light direction
Ideal for use as a symmetrical floodlight with aluminium reflector and yoke arm
Specifications
GL4 well glass
Classification Rated voltage
Group IIII, Zone 1 & 2, 220-250 V ±10 %, 50 Hz GL4 with aluminium dome reflector
IIIIB + H2), T3
Exd Gas group IIIIA & II B (II
Approval Ambient temperature
AUS Ex 2017 to AS 2380-2 (IEC 60079 -1) -20 ˚C to 50 ˚C
Degree of protection Lamp holder
IP 66 Porcelain E27 or E40
Housing material Terminals
Marine grade corrosion resistant High grade melamine up to 4 sq mm
aluminium alloy or cast stainless steel
grade 316
Diffuser Weight
Impact resistant toughened glass Aluminium alloy - 24 kg
Stainless steel - 37 kg
Reflector Cable entry
Polyester, aluminium Standard 2 x M20
Control gear integral
Standard finish
RAL7032 for aluminium alloy fitting
Stainless steel - unpainted
Options
1. Luminaire housing from cast stainless steel grade 316.
2. Other voltages and frequencies available.
3. Two coat epoxy paint finish. GL4 with well glass
4. Other cable entries available as requested.
Accessories
1. Variety of reflectors.
2. Wire guard for glass globe.
1-6
SECTION 1 Ex LIGHTING
Features
• Body is produced from non corrosive glass fibre reinforced polyester
• Diffuser is produced from impact proof polycarbonate, textured for improved light Govan Golux 2 series luminaires are for
distribution general purpose lighting, suitable for
outdoor and indoor applications, in Exn
• Retaining clips for diffuser are made from corrosion resistant stainless steel
and D.I.P hazardous locations
• Gear tray is powder coated white and is removed by single action securing locks,
and attached with safety cords for ease of maintenance
• Quality control gear is used to ensure a high running efficiency
• Entry configuration allows through wiring, and on twin tube units an additional
entry at one end, up to M20
• Standard control gear 240 V, 50 Hz. Other voltages on request
• Eye bolt mounting supplied as standard, optional mounting available
• Power factor correction
Dimensions (mm)
Specifications
GL2 fluorescent fixture
Classification Degree of protection
IEC 60079-0 IP66
IEC 60079-15
IEC 61241-1-1
Approval Type of protection
Certificate No. IECEx CSA 07.0005X nA, DIP
Ex nA IIC T3 IP66
DIP A21 Ta T4 IP66
Ordering Information
Dimensions (mm)
Watts Weight A B C D Cat. NO.
2 x 18 2.6 kg 676 398 154 124 GL2-18T
2 x 36 5.5 kg 1276 798 154 124 GL2-36T
2 x 58 6.8 kg 1576 1100 154 124 GL2-58T
Options
• Add option suffix to catalogue number : -Suffix
• Through wiring (M20 entry each end) : -T
• Ceiling mounting : -C
• Eyebolt hanger mounting : -H
• Pipe mounting (1 - 1/4" pipe) : -P
• Wall mounting (90 degrees) : -W
• Maintained emergency battery pack : -ME
• Non-maintaining emergency battery pack : -NME
• Typical ordering code : GL2-36T-T-C-ME
1-2
SECTION 1 Ex LIGHTING
Specifications
Gl3 Well glass
Classification Degree of protection
ExnR Group IIII, Zone 2 to AS 2380.9 IP 66 to AS 1939
D.I.P Group II to AS 2236
Gas group IIC
Approval Temperature class
Certificate No. Ex 967x T2-T3 (up to 250 W with prismatic glass )
D.I.P Certificate AUS Ex 935x T4 ( up to 250 W Reflector/Lens)
T3 (400 W Reflector/Lens)
Technical Data
Voltage / Frequency 240 V/50 Hz … Other voltages available on request Cat. No. GL3
Wattage Mercury Vapour 50, 80, 125, 250, 400 W
Metal Halide 175, 250, 400 W
High Pressure Sodium 50, 70, 150, 250, 400 W
Power factor 0.85, Integral Ballast Dimensions (mm)
Weight MV MH HPS
Under 250 W 10 kg 15 kg 11 kg
250W 11 kg 16 kg 12 kg
Ceiling
400 W 12 kg 18 kg 14 kg Mounting
Lamp Holder Porcelain E27 (low wattages) or E40 (high wattages)
Terminal Block High grade Melamine for up to 4 mm2 wire. Insulation grade
105 ˚C up to 250 W, 115 ˚C for 400 W
Cable Entries 2 x M25 conduit standard, M20 optional. (One entry
plugged and available for restricted breathing test of
installation).
Materials High grade cast aluminium body, grey enamel finish.
Silicone rubber seals. Stainless steel external hardware.
Fibreglass reinforced polyester or spun aluminium reflectors. Pendant
Mounting
Photometrics
Stanchion
Mounting
1-8
SECTION 1 Ex LIGHTING
O rdering Information
Temp Ceiling Mount Pendant Mount Wall Mount 15˚ Wall Mount
Lamp Type Watts Rating Cat. No. Cat. No. Cat. No. Cat. No.
Incandescent 75 T5 GL10N07C GL10N07P GL10N07W GL10N07AW
Incandescent 1 0 T5 GL10N010C GL10N10P GL10N10W GL10N10AW
Incandescent 150 T5 GL10N015C GL10N15P GL10N15W GL10N15AW
Incandescent 200 T4 GL10N020C GL10N20P GL10N20W GL10N20AW
Self ballasted mercury 100 T5 GL10M10C GL10M10P GL10M10W GL10M10AW
Self ballasted mercury 160 T3 GL10M16C GL10M16P GL10M16W GL10M16AW
Fluorescent SL 18 T6 GL10F18C GL10F18P GL10F18W GL10F18AW
Fluorescent SL 23 T6 GL10F23C GL10F23P GL10F23W GL10F23AW
1-5
SECTION 1 Ex LIGHTING
Standards Compliance
Exd : CLASS 1 ZONE 1 TO AS 2380.2
GAS GROUPS : II C
TEMPERATURE : T5, T6
DEGREE : IP66
Exd APPROVAL : AUS Ex 3735
Features
• Control box and end cap are from a corrosion resistant Aluminium alloy.
• Polycarbonate tube outer case. ( Optional Toughened Glass Tube Outer case)
• Screwed Body arrangement is easily disconnected for lamping of fitting.
• Powder coated mild steel mounting reflector for greater light distribution.
• Standard control gear supply is 240V. 50Hz. Other supplies available on request.
• Entry 2x M20 (Standard)
OPTION: Emergency light fitting available with 2-hour battery back-up. Other
ratings on request.
Emergency Light Cat No.: GL7-T18-ME (TYP) For maintained emergency.
GL7-T18-NME (TYP) For non-maintained emergency.
1-3
SECTION 1 Ex LIGHTING
Ordering Information
Ceiling Mount Pendant Mount Stanchion Mount Wall Mount
Lamp Type Watts Cat. No. Cat. No. Cat. No. Cat. No.
Mercury vapour 80 GL4M08C GL4M08P GL4M08S GL4M08W
Mercury vapour 125 GL4M12C GL4M12P GL4M12S GL4M12W
Mercury vapour 250 GL4M25C GL4M25P GL4M25S GL4M25W
Mercury vapour 400 GL4M40C GL4M40P GL4M40S GL4M40W
HPS 70 GL4S07C GL4S07P GL4S07S GL4S07W
HPS 150 GL4S15C GL4S15P GL4S15S GL4S15W
HPS 250 GL4S25C GL4S25P GL4S25S GL4S25W
HPS 400 GL4S40C GL4S40P GL4S40S GL4S40W
Metal halide 175 GL4H17C GL4H17P GL4H17S GL4H17W
Metal halide 250 GL4H25C GL4H25P GL4H25S GL4H25W
Metal halide 400 GL4H40C GL4H40P GL4H40S GL4H40W
Stanchion
Mounting
1-7
SECTION 1 Ex LIGHTING
Features
• The GL 10 series luminaire is a well glass light fitting without control gear suitable
for hazardous area Group II Zone 1 & 2. It can be fitted with lamps up to 200 watt
incandescent, 160 watt self ballasted Mercury Vapour and SL type fluorescent
up to 25 watt
• Stainless steel hardware
• Ribbed body for added strength and better cooling of the light fitting
• One piece silicon gasket for water tight seals
• Variety of mounting arrangements
• Choice of reflectors in polyester
GL10 with polyester dome reflector
• Toughened and tempered heat r esistant glass
Specifications
GL10 Well glass
Classification Ambient temperature
IEC 60079-0 -20 ˚C to 50 ˚C
IEC 60079-1
Approval Lamp holder
IECEx TSA 07.0004X Porcelain ES or BC
Exd IIB T* IP66
Temp Class : T3-T6
ATEX : Sira 07ATEX1131X
II2G
Degree of protection Terminals
IP 66 Insulated connectors up to 4 sq mm
Housing material Weight
Marine grade corrosion resistant Aluminium alloy - 7 kg
aluminium alloy or cast stainless steel Stainless steel - 15.5 kg
grade 316
Diffuser Cable entry
Impact resistant toughened glass Standard 2 x M20
Reflector Standard finish
Polyester RAL7032 for aluminium alloy fitting
Stainless steel - unpainted
Rated voltage
220-250 V ±10 %, 50 Hz
Options
1. Luminaire housing from cast stainless steel grade 316.
2. Other voltages and frequencies available.
3. Two coat epoxy paint finish.
4. Other cable entries available as requested.
Accessories
1. Variety of reflectors.
2. Wire guard for glass globe.
3. Cast aluminium guard.
1-4
SECTION 1 Ex LIGHTING
Ordering Information
The above fixtures are fitted with prismatic glass globes as standard up to 250 watt and
refractor glass as standard on 400 watt lights. If guards, reflectors or different optics are
required then the following suffix should be added to the basic code selected above.
1-9
SECTION 1 Ex LIGHTING
The GOLUX 9 stainless steel luminaire is a high intensity discharged light fixture for use
with Mercury Vapour, High Pressur e Sodium and Metal Halide lamps up to 400 watt.
The GOLUX9 light fitting is designed for Group II Zone 2 hazardous areas with extreme
corrosive environments.
Typical examples of these types of areas are oil and gas platforms, refineries, wharfs,
jetties and any environments where salt water or salt laden air creates corrosion problems.
Specifications
GL9 Stainless steel luminaire
Classification Degree of protection
ExnR Group IIII, Zone 2 to AS 2380.9 (IEC 60079-15) IP 66
Gas group IIIIC
Approval Temperature class
Certificate AUS Ex 2035X T2-T4
Voltage/Frequency Power factor
220-250 V, 50 Hz (other voltages available) 0.85 Cat. No. GL9
Wattage Weight
Mercury Vapour … 50, 80, 125, 250, 400 W MV - 11 kg
Metal Halide … 175, 250, 400 W MH - 16 kg
High Pressure Sodium 50, 70, 150, 250, 400 W HPS - 12 kg
Ambient temperature Lamp holder
-20 ˚C to 50 ˚C Porcelain E27 E40
Cable entries Control gear
2 x M25 conduit standard, other sizes Integral
optional. Pendant 1 … 1/4" BSP.
Features
The fittings housing and covers are produced from 1.5 mm thick 316
grade stainless steel
All securing screws and other hardware used is stainless steel
Control gear is integrally mounted and is easily accessible for maintenance
Factory mounted terminal block for ease of field wiring
One piece silicon gaskets for long lasting water tight seals
Heat resistant clear prismatic glass globe fitted to housing by screwing into a
stainless steel 316 grade retaining ring
1-10
SECTION 1 Ex LIGHTING
Features
Remote gear (in either Exn or Exd enclosure)
Long life and low maintenance
Adjustable lamp bracket for required aiming angle
Floodlight … Heavy duty die cast, low copper content aluminium body, large
efficient 99.9 % pure non-ageing aluminium reflector. Hot dip
galvanised mounting bracket (or powder coated). Stainless steel
external screws, nuts, bolts and clips
Glass … Toughened safety. High temp. silicon rubber gaskets
Beam types … Narrow (5 x 2), Wide (6 x 6) Cat. No. GD (Titan)
Lamp … Bench tested and supplied with each floodlight
… All lamps are high output HID tubular type
Control gear … Standard reactor type to .85 pfc, supplied separately on a
pre-wired and tested gear tray assembly; or Exn / Exd enclosures
IP Rating … IP 66, Simtars Report No. NE92/0129
Dimensions (mm)
Applications
Large area lighting, car park, industrial sites, jetties, tank farms, marshalling yards,
marinas, quays, security areas, wharfs, refineries and petrochemical complexes etc.
Specifications
GD Floodlight
Classification Degree of protection
ExnR Group II , Zone 2 IP 66
Gas Group IIIIC
Approval Temperature class
Ex 2034X to AS 2380.9 (IEC 60079 -15) T2
Circuit diagram
Accessories / Options
GD1185 240 V to 415 V transformer
GD1186 240 V 2 kW lamp and ignitor
GD1190 cast aluminium waterproof gear box
GD1192 louvre, vertical
GD1193 415 V gear and D1190
GD1195 louvre, horizontal
1-14
SECTION 1 Ex LIGHTING
Features
The GL16 series luminaire is a high intensity discharge (H.I.D) floodlight fitting
suitable for use in hazardous area, Zone 1 and 2. It can be fitted with lamps up to
600 watt high pressur e Sodium or up to 400 watt Mercury Vapour and Metal Halide
Hinged cover for ease of maintenance and relamping
Stainless steel hardware
Yoke mounting allows a 120˚ rotation in the vertical plane for setting light direction
Integral control gear
Variety of mounting arrangements
Specifications
GL16 Floodlight Diffuser
Classification Degree of protection
Zone 1 & 2 Exd IP 66
Gas group IIIIB + H 2
Approval Housing material
AUS Ex 3660X to AS 2380 -2 (IEC60079 -1) Marine grade corrosion
resistant Aluminium alloy
Cat. No. GL16
Diffuser Reflector
Impact resistant toughened glass High purity anodised
aluminium
Rated voltage Ambient temperature
220-250 V ±10%, 50 Hz -20 ˚C to 50 ˚C
Lamp holder Terminals
Porcelain ES 40 High grade melamine up
to 4 sq mm
Luminaire weight Cable entry
Aluminium - 42 kg without control gear Standard 2 x M25
Control gear
Integral
Options
1. Other voltages and frequencies available
2. Two coat epoxy paint finish
3. Other cable entries available as requested
Accessories
1. Pole mounting adaptor
2. Wire guard
3. Deflector / Weather hood
1-12
SECTION 1 Ex LIGHTING
Ordering Information
Lamp Yoke mount Pole mount Wall mount
type Watts T rating Cat. No. Cat. No. Cat. No.
Metal halide 250 T3 GL16H25Y GL16H25P GL16H25W
Metal halide 400 T2 GL16H40Y GL16H40P GL16H40W
HPS 250 T3 GL16S25Y GL16S25P GL16S25W
HPS 400 T2 GL16S40Y GL16S40P GL16S40W
Mercury vapour 250 T3 GL16M25Y GL16M25P GL16M25W
Mercury vapour 400 T2 GL16M40Y GL16M40P GL16M40W
Pole Mounting
1-13
SECTION 1 Ex LIGHTING
Ordering Information
Options
Suffix to be added to code
Polyester, 30˚ angle A
Polyester dome D
Wire guard 1
Typical examples of codes:
GL9M12W-A1, GL9S25C-BS
Notes
1 Lamps not included as part of
supply unless specifically
requested as a priced option.
2 Specify conduit entry size (default
size is M25)
1-11
SECTION 1 Ex LIGHTING
Isolux Contours
(Titan wide beam floodlight)
The isolux contours are standardised in a grid determined by the mounting height (h).
Used as a design tool, the accompanying multi-purpose contours, makes it possible to
estimate the area covered and illuminance levels, based upon the nominated mounting
height/scale related contours for each lamp type.
The position of the maximum Eh value is marked (A) and is 100 %. The isolux contours
B, C, D and E are percentage contours of that maximum.
The curves and effective illuminances are valid only, when the TITAN GD 115 floodlight
is aimed at 65˚ to the downward vertical.
1-15
SECTION 1 Ex LIGHTING
Features
Both body and cover are made of heavy duty one-piece pressure die cast low copper
content aluminium or stainless steel fabricated fitting type GL5
Hinged cover for ease of access to integral ballast and capacitor
Thermal shock and impact resistant glass lens
Gaskets are of heavy duty, high temperatur e silicon rubber GL5/2 Flood Light Fitting
Porcelain heavy duty ES40 socket with spring loaded centre contact and brass nickel
plated double lamp grip screw shell
High grade dimpled, pure aluminium reflector
Different mounting options available
1-16