Furman Catalog
Furman Catalog
ADVANCED POWER
                      MANAGEMENT SOLUTIONS
                     FOR AUDIO, VIDEO, AND
                   BROADCAST PROFFESSIONALS
    PRODUCT CATEGORY
2
FURMAN FEATURES AND TECHNOLOGIES
Audio/video professionals can never accept downtime, corrupted                        and surges your equipment is exposed to on a daily basis.
data, or unreliability. It is for this reason that a robust, professional             These common voltage fluctuations, although small, can have a
level transient voltage surge suppression system, such as SMP,                        serious adverse effect over the long-term. Even when protected
is the best choice for critical applications.                                         by a standard surge protector, digital circuits can see long-term
With SMP, there is virtually no downtime. In fact, the circuit is                     damage due to exposure to voltage on the ground line, causing
tested to handle multiple 6000 volt or 3000 amp pulses without                        intermittent behavior, equipment lock-ups, and data loss.
sustaining any damage. This is far beyond the demands placed on
typical surge suppressors. But because of the extreme conditions
and critical applications faced by Furman’s clients, the SMP
circuit has been designed to pass this severe test and ensure that
equipment damage or maintenance is extremely unlikely.
Furman’s SMP relies on a network of components to slow down
the impact of a potentially catastrophic surge by capturing it,                       TOP: Furman’s SMP Circuit: 188V Pk measured let-through voltage
dissipating it in the form of heat, and absorbing the remaining                       BOTTOM: Typical non-sacrificial circuit: 461V Pk measured let-through voltage
excess energy. When tested with multiple 6,000V/3,000A surges,
the SMP circuit’s maximum let-through voltage is only 376V Pk /
266V RMS on a 230V line. Due to the design of the circuit, it will
not degrade over time (unlike most standard surge suppressors)
and will show minimal increase in line impedance (unlike many
advanced surge suppressors).
The SMP circuit is not simply designed to protect from a
catastrophic surge, such as a lightning strike – it is engineered                     By absorbing these everyday surges without deterioration of
to provide maximum life to connected equipment. This means it                         the circuit or contamination of the ground line, Furman’s SMP
not only protects from devastating spikes and surges, but also                        maximizes the longevity of connected equipment and minimizes
offers protection from the dozens to hundreds of small spikes                         the risk of downtime or failure in mission-critical applications.
                                                                                                                                           www.furmanpower.com        3
                                    220V-440V PRO LINE PRODUCT CATALOG
SMARTSEQUENCINGTM
    SmartSequencing technology allows large and complex Pro A/V             at runs of over 300 meters with bi-directional communications
    systems to be safely powered on and off with a simple press of          between units for sequencing on and off large and/or complex
    a button or turn of a key. Multiple units may be daisy chained          systems.
4
                                                                                                                      TECHNOLOGY
Another power quality issue facing today’s electronics is              damage your equipment. When the voltage is lower than optimal,
irregular voltage. While we may expect constant voltage to be          your equipment’s power supply must work harder to create
supplied by our power utility, such an expectation is not realistic.   more electrical current in order to make up for the difference,
Because of the chaotic demands on many power facilities and            creating a “tug-of-war” in your power supply. This can cause
deterioration of power lines, AC voltage is often reduced so           your equipment to malfunction or sustain permanent damage.
that it can be stretched to fulfill excess demand. This creates a      Furman’s True RMS Voltage Regulation is designed around an
substantial negative impact on your A/V equipment performance.         ultra-low noise toroidal autoformer. A microprocessor within the
Additionally, many regions and many applications require               regulator monitors the incoming RMS voltage with each cycle,
equipment be run by generator power. Since generators typically        measuring the phase angle in time with the advancing cycle.
have voltage output specifications based on a constant current         Most commercial voltage regulators using multiple-tapped
load, they are far from ideal for use in an A/V system which will      transformers switch taps at uncontrolled times. This creates
typically see massive swings in the current draw. For this reason,     voltage spikes and clicks that can leak into audio. When a voltage
generator power should always be followed by voltage regulation        fluctuation requires correction, Furman’s True RMS Voltage
in an A/V application.                                                 Regulation advances a new tap with less stress than other
                                                                       technologies and, in turn, avoids distortion to the AC waveform.
          True RMS Voltage Regulation is                               Hysteresis in the circuitry avoids the unnecessary switching
          achieved through the use of an                               back and forth between the adjacent taps (or “chatter”) found in
      ultra-quiet, microprocessor controlled                           many commercial voltage regulators. If necessary, Furman’s True
      autoformer with solid-state switching.                           RMS Voltage Regulation technology can switch taps as often
                                                                       as once each cycle and do so with a shorter recovery time than
                                                                       a commercial voltage regulator. In addition and unlike voltage
Today’s power supplies are designed to operate at their optimum        regulators that employ ferroresonant transformers, Furman
input - anywhere between 120V to 240V, depending on the region.        regulators are not sensitive to small errors in line frequency,
When the voltage delivered is higher than the regional standard,       making them ideal for use with generators. The autoformer’s
your equipment is subject to extra electricity that can overheat or    toroidal design assures minimal leakage of stray magnetic fields.
POWER SEQUENCING
Power sequencing is useful whenever various kinds of equipment         any large system whose components present an inductive load to
must be powered up or down in groups, rather than all                  the AC line (including electric motors, power supplies, and power
simultaneously. In audio systems, sequenced powering is often          amplifiers of all kinds), sequenced powering can avoid excessive
necessary to allow turn-on transients from low level amplifiers and    inrush currents that can cause circuit breakers to trip even though
processors to settle down before any power amps are turned on,         the steady-state currents are not excessive. Power sequencing is
because simultaneous powering would result in a loud, annoying,        particularly suited to applications where large installations must
and potentially destructive “pop” reaching the speakers. And, in       be switched by inexperienced personnel.
IP/RS-232 CONTROL Available on select models for custom control and integration.
                                                                                                                 www.furmanpower.com         5
                                                  220V-440V PRO LINE PRODUCT CATALOG
     Standard Level     Standard Level      11 Outlets    10A Rating       Protection OK     Front Panel
    Surge Protection   RFI/EMI Filtration                                    Indicator       Retractable
                                                                                                Lights
    Merit X Series Specifications: Maximum Output Current:10 Amps. Line Cord: 1.5 meter, removable, IEC C-13 female to Schuko male. Lamps (M-10Lx E): Two multi-LED, dimmable lamps.
    Spike Protection Mode: Fused MOV, Line to neutral. Operating Voltage: 230VAC 50 Hz. Energy Dissipation: 305 joules. Peak Impulse Current: 12,000 amps.
    Noise Attenuation (Transverse Mode): Greater than 20dB, 1.5Mhz to 200 Mhz. Dimensions: 44.45mm H x 482.6mm W x 190.5mm D. Weight: 2.3 kg. Safety Agency: CE. Warranty: Three Year.
6
                                                                        MERIT X SERIES / CLASSIC SERIES POWER CONDITIONERS
 SMP Advanced       Linear Filtering   EVS Voltage   11 Outlets      10A Rating    Diagnostic Lights   Isolated Outlet   Front Panel    Rear Panel BNC
Surge Protection      Technology        Protection                                                          Banks        Retractable     Connector for
                                                                                                                            Lights     Gooseneck Lamp
 SMP Advanced       Linear Filtering   EVS Voltage   11 Outlets     10A Rating    Diagnostic Lights    Isolated Outlet   Front Panel    Rear Panel BNC   LED Voltmeter
Surge Protection      Technology        Protection                                                          Banks        Retractable     Connector for
                                                                                                                            Lights     Gooseneck Lamp
Classic Series (10A) Specifications: Maximum Output Current:10 Amps. Line Cord: 2.5M, removable, IEC female to Schuko male. Lamps: Two multi-LED dimmable lamps.
Spike Protection Mode: SMP, Line to neutral, zero ground leakage. Maximum Continuous Operating Voltage: 274V. Let Through Voltage: 376V Pk / 266V RMS @ 3,000 Amps.
Noise Attenuation (Transverse Mode):10 dB @ 10 kHz, 40 dB @ 100 kHz, 50 dB @ 500 kHz. BNC Connector: 12VAC 500MA max (lamp not included). Dimensions: 482.6mm W x 266.7mm D x 44.45mm H
Weight: 6 kg. Safety Agency: CE. Warranty: Five Year.
                                                                                                                                                          www.furmanpower.com             7
                                                 220V-440V PRO LINE PRODUCT CATALOG
     SMP Advanced      Linear Filtering   EVS Voltage    11 Outlets       16A Rating    Diagnostic Lights   Isolated Outlet       Front Panel     Rear Panel BNC      Dual Voltage/      USB Charger
    Surge Protection     Technology        Protection                                                            Banks            Retractable      Connector for      Current Meter
                                                                                                                                     Lights      Gooseneck Lamp
    Classic Series (16A) Specifications: Maximum Output Current:16 Amps. Line Cord: 2.5M, removable, IEC female to Schuko male. Lamps: Two multi-LED dimmable lamps.
    Spike Protection Mode: SMP, Line to neutral, zero ground leakage. Maximum Continuous Operating Voltage: 274V. Let Through Voltage: 376V Pk / 266V RMS @ 3,000 Amps.
    Noise Attenuation (Transverse Mode):10 dB @ 10 kHz, 40 dB @ 100 kHz, 50 dB @ 500 kHz. BNC Connector: 12VAC 500MA max (lamp not included). USB Circuit: 500 mA@5VDC, USB-A Connector.
    Dimensions: 482.6mm W x 266.7mm D x 44.45mm H Weight: 6 kg. Safety Agency: CE. Warranty: Five Year.
                                                                                                SMP Advanced       Linear Filtering   Auto-Reset EVS      2 Outlets         10A Rating     Diagnostic Lights
                                                                                               Surge Protection      Technology           Voltage
                                                                                                                                        Protection
    AC-210A E Specifications: Maximum Output Current:10 Amps. Line Cord: 2.5M, removable, IEC female to Schuko male. Spike Protection Mode: SMP, line to neutral, zero ground leakage.
    Extreme Voltage Shutdown: 275 VAC (Auto-Reset). Let Through Voltage: 376V Pk / 266V RMS @ 3,000 Amps. Noise Attenuation (Transverse Mode):10 dB @ 10 kHz, 40 dB @ 100 kHz, 50 dB @ 500 kHz.
    Dimensions: 44.5mm H x 127mm W x 216mm D. Weight: 1.36 kg. Safety Agency: CE. Warranty: Three Year.
8
   CLASSIC SERIES / COMPACT / PRESTIGE SERIES VOLTAGE REGULATOR / POWER CONDITIONERS
 SMP Advanced        Linear Filtering    EVS Voltage    True RMS Voltage        11 Outlets   6A Rating   Diagnostic Lights   USB Charger   Isolated Outlet   Dual Voltage/    Rear Panel BNC
Surge Protection       Technology         Protection       Regulation                                                                           Banks        Current Meter     Connector for
                                                                                                                                                                             Gooseneck Lamp
P-1400 AR E Specifications: Maximum Output Current: 6 Amps. Output Voltage: Selectable between 230V and 240V, ±10V. In Regulation Range: 174 to 264 VAC.
Line Cord: 2.5M, removable, IEC female to Schuko male. Spike Protection Mode: SMP, Line to neutral, zero ground leakage. Maximum Continuous Operating Voltage: 275V.
Let Through Voltage: 376V Pk / 266V RMS @ 3,000 Amps. Noise Attenuation (Transverse Mode):10 dB @ 10 kHz, 40 dB @ 100 kHz, 50 dB @ 500 kHz. USB Circuit: 500 mA@5VDC, USB-A Connector.
BNC Connector: 12VAC 500MA max (lamp not included). Dimensions: 482.6mm W x 305mm D x 45mm H Weight: 7 kg. Safety Agency: CE. Warranty: Five Year.
  10A Rating       Diagnostic Lights    USB Charger    Isolated Outlet     Dual Voltage/
                                                            Banks          Current Meter
P-2300 IT E Specifications: Maximum Output Current: 10 Amps. Line Cord: Detachable cord, 1mm x 3, 2.5m long, Schuko plug to IEC C13. Spike Protection Mode: SMP, Line to neutral, zero ground
leakage. Maximum Continuous Operating Voltage: 275V. Let Through Voltage: 376V Pk / 266V RMS @ 3,000 Amps. Noise Attenuation (Transverse Mode):10 dB @ 10 kHz, 40 dB @ 100 kHz,
50 dB @ 500 kHz. Noise Attenuation (Common Mode): >80 dB @ 20 kHz, >40 dB @ 20 kHz-1 MHz. Dimensions: 133mm H X 483mm W X 356mm D Weight: 43 kg. Warranty: Five Year.
                                                                                                                                                                www.furmanpower.com             9
                                                   220V-440V PRO LINE PRODUCT CATALOG
      SMP Advanced      Linear Filtering    EVS Voltage   True RMS Voltage    11 Outlets
     Surge Protection     Technology         Protection      Regulation
        30A Rating      Diagnostic Lights   USB Charger    Isolated Outlet   Dual Voltage/
                                                                Banks        Current Meter
     P-6900 AR E Specifications (Note - Preliminary Specifications, subject to change): Maximum Output Current: 30 Amps. Output Voltage: Selectable between 230V and 240V, ±10V.
     In Regulation Range: 174 to 264 VAC. Line Cord: 30A C-Form connector with female mating connector for termination of custom line cord. Spike Protection Mode: SMP, Line to neutral, zero ground
     leakage. Maximum Continuous Operating Voltage: 275V. Let Through Voltage: 376V Pk / 266V RMS @ 3,000 Amps. Noise Attenuation (Transverse Mode):10 dB @ 10 kHz, 40 dB @ 100 kHz,
     50 dB @ 500 kHz. USB Circuit: 500 mA@5VDC, USB-A Connector. Dimensions: 482.6mm W x 406.4mm D x 133.35mm H (without line cord connector), 482.6mm W x 597mm D x 133.35mm H
     (with line cord connector). Weight: 26 kg. Warranty: Five Year.
                                                                                                    P-2300 IT E
                                                                                                    Furman’s 40 kg. isolation transformer (in the P-2300 IT E) works much
                                                                                                    like balanced audio at a higher voltage. The incoming AC is split from
                                                                                                    230V on the line to 115V on the line and neutral when referenced to the
                                                                                                    new 0V ground. Since these voltage paths are in opposite polarity, all
                                                                                                    noise on the incoming AC line is cancelled, resulting in a substantially
                                                                                                    lower noise floor and allowing harmonics and overtones in audio content
                                                                                                    to shine through without the masking effects of AC noise.
10
                                                          POWER CONDITIONER / CONTRACTOR SERIES SMARTSEQUENCERSTM
             Sequence On/Off Switch               SmartSequencing          Delay 1, 2,      Potentiometer DIP switches       LED Indicators for  Convenient           Circuit           Key switch      Integrated
                                                  Primary Port Status      and 3 LED        to Fine Tune  for configuring    Unswitched Power, Front Panel            Breaker           (2 keys         Rack Ears
                                                                           Indicators       Delay Time    outlet delay       Protection OK,      Outlet               16A Thermal       included)
                                                  SmartSequencing                                                            and Extreme Voltage
                                                  Secondary Port
                                                  Status
 1.5mm2x3, 2.5 m Long IEC 60320 C-20               Unswitched                    Delay 1 Duplex            Delay 2 Duplex             Delay 3 Duplex             Ethernet Accessory Port D-Subminiature 9-pin female
 Female to Schuko CEE 7/7 Male Plug                Duplex                        (Configurable Delay)      (Configurable Delay)       (Configurable Delay)       with threaded standoffs, IP Addressability: Optional, via
                                                                                                                                                                 BB-RS232 Ethernet/RS-232 Adaptor (sold separately) for
                                                                                                                                                                 IP control via Telnet, HTTP, BlueBOLT®
 CN-3600 SE AC Cord
 1.5mm2x3, 2.5 m Long
 IEC C-19 Female to
 CEE 7/7 Male Plug
CN-3600 SE Specifications: AC Voltage Input Range: 180-270 VAC, 50/60Hz. Maximum AC Current Rating: 16 Amps (Thermal breaker). AC Cord: 1.5mm2x3, 2.5m Long, black, IEC C-19 Female to Schuko
CEE 7/7 Male Plug. AC Receptacles: Convenience Outlet (Front Panel) 1 IEC C-13 (Unswitched); Rear Panel Outlets: 1 IEC C 13 pair (Unswitched), 3 IEC C13 pairs (Sequenced, each pair is controlled by separate
relay). Surge/Under-Overvoltage Protection: AC Surge Protection: Series Multi-Stage Protection (SMP); Spike Protection Mode: Line to neutral, zero ground leakage; Spike Clamping Voltage: 375 V peak
@ 6,000 volts/3,000 amps ; Response Time: 1 nanosecond; Maximum Surge Current: 6,500 Amps; AC Undervoltage Protection: 175VAC+/-5VAC; AC Overvoltage Protection: EVS, 275VAC+/-5VAC; AC Overvoltage
Reset Modes: Manual and Auto-reset (configurable). AC Filtering: LiFT; Noise Attenuation: Linear, 10dB @10KHz, 40dB@100KHz, 50dB@500KHz. Operating Temperature Range: 5C (40F) to 40C (105F)
degrees. Humidity Range: <90% rH (Relative Humidity). User Interface: Key switch: Front panel, 3-position key switch (On, Off, Remote); Keys: Included, 1 pair; Pushbutton Switch: Front panel, hidden by
security cover; Circuit Breaker: Front panel, pushbutton, 16A Thermal Breaker; Front panel diagnostic indicators: Primary link, Secondary link, Ethernet, Remote off, Delay 1, Delay 2, Delay 3, Power, Protection
OK, Extreme Voltage; Front Panel DIP Switches: Hidden by security cover, 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off GND Mode On, Momentary/Maintained, Primary/
Secondary, EVS Reset Auto/Manual; Potentiometer: Front panel, hidden by security cover, fine tune delay adjust. Control/Status/Triggering (Rear Panel): Remote Terminal: +5-30VDC In, 12VDC (10mA) Out;
SmartSequencing: Phoenix-type 4-Pin Connector, Screw Terminals, Primary & Secondary Links (Current Loop - 300 m nominal); Remote Terminal: Phoenix-type 4-Pin Connector With Screw Terminals; +12V, STAT,
REM, GND; Force Off/Delay 3 Terminal: Phoenix-type 5-Pin Connector With Screw Terminals, FORCE OFF, DELAY 3; RS-232 Compatible: Yes, DE-9 Connector; IP Accessibility: Optional, via BB-RS232 Ethernet/RS-232
Adaptor (sold separately) for direct IP control via Telnet, HTTP, BlueBOLT®; Voltmeter: Available data via RS-232 or Ethernet option, +/- 2VAC accuracy; Ammeter: Available data via RS-232 or Ethernet option,
+/-1A accuracy. Power Consumption (No Load): 10 Watts. Dimensions: 483mm W x 280mm D x 45mm H Weight: 5.44 kg. Warranty: Fifteen Years. Safety Agency Mark: CE. RoHS Compliant: Yes
                                                                                                                                                                               www.furmanpower.com                       11
                                                       220V-440V PRO LINE PRODUCT CATALOG                                                                           POWER SEQUENCER /
      Linear Filtering    EVS Voltage       Power Sequencing     9 Outlets         10A Rating       Diagnostic Lights   Isolated Outlet      Rear Panel BNC
        Technology         Protection                                                                                        Banks             Connector
                                                                                                                                          for Gooseneck Lamp
     PS-8R E II Specifications: Maximum Output Current: 10 Amps. Delay Banks: 3 banks, adjustable delay, local or remote control. Line Cord: 2.5M, removable, IEC female to Schuko male.
     Spike Protection Mode: SMP, Line to neutral, zero ground leakage. Maximum Continuous Operating Voltage: 276V. Let Through Voltage: 376V Pk / 266V RMS @ 3,000 Amps.
     Noise Attenuation (Transverse Mode):10 dB @ 10 kHz, 40 dB @ 100 kHz, 50 dB @ 500 kHz. BNC Connector: 12VAC 500MA max (lamp not included). Dimensions: 482.6mm W x 220mm D x 44.45mm H
     Weight: 3.1 kg. Safety Agency: CE. Warranty: Thee Year.
                                                                                                                                                                                   Compatible
                                                                                                                                 with BlueBOLT-CV1 interface card (sold separately): provides remote
                                                                                                                               access to reboot components, power equipment on or off, and monitor
                                                                                                                                           power quality overthe Internet from anywhere in the world.
      SMP Advanced       Linear Filtering      Extreme Voltage    Battery Backup     Digital Indicators   Dual Learning IR         Custom          Critical Load       BlueBOLT
     Surge Protection      Technology             Shutdown        Protects Data                              Blasters           Programming        Management         Compatible
     F1500-UPS E Specifications: Current Rating: 10 Amps. Outlets: 4 Critical Load (2 banks - 2 outlets per bank), 6 Non-Critical load (2 banks - 3 outlets per bank) Line Cord: 3M, removable, with retention clip.
     Spike Protection Mode: SMP, Line to neutral, zero ground leakage. Voltage: 170 - 286 VAC Overvoltage Shutoff, fast rise: 300±10V Overvoltage Shutoff, slow rise: 296±5V
     Noise Attenuation:10 dB @ 10 kHz, 40 dB @ 100 kHz, 50 dB @ 500 kHz. UPS Output Capacity: 1500VA, 900W @ 0.75pf (7.5A) UPS Back-up Time: 12 Minutes at full load, 32 Minutes at half load
     Dimensions: (without rack ears) 432mm W x 488mm D x 90mm H Weight: 32.7 kg. Safety Agency: CE. Warranty: Three Year.
12
CONDITIONER / UNINTERRUPTIBLE POWER SUPPLY / POWER CONDITIONER / GOOSENECK LAMPS
GOOSENECK LAMPS
           GN-I / GN - LED Gooseneck Lamps
Furman’s 12” gooseneck lamps provide incandescent (GN-I) and LED (GN-LED)
illumination with a locking BNC connector, ideal for use with many Furman
products that provide a rear BNC connector for discreet illumination at the back
of an equipment rack.
ICON GLOSSARY
                                                                       DIGITAL VOLTMETER/AMMETER
                                                                       Switchable, dimmable digital meter displays incoming voltage,
                                                                       switchable to output current in amps. Display also features
FRONT PANEL RETRACTABLE LIGHTS                                         Protection OK, Extreme Voltage, and color-coded Voltage Range
Furman’s signature front panel retractable lights provide              indicators for comprehensive power monitoring.
convenient, discreet illumination to a rack full of equipment.
Standard models include incandescent lights. Advanced
models feature long-lasting, cool running LED lights.
                                                                       USB CHARGER
                                                                       Front-panel USB charger provides convenient charging
                                                                       outlet for most personal media devices and cell phones.
BLUEBOLT®
Provides remote access to reboot components, power
equipment on or off, and monitor power quality over the
Internet from anywhere in the world.
LED VOLTMETER
Segmented LED Voltage Meter. Indicates incoming voltage                STANDARD LEVEL EMI/RFI FILTRATION
ranging from 180V to 254V. The LED’s are color coded                   Standard level non-linear AC noise filtration.
(Red=Stop, Yellow=Caution, Green=Go) to inform users
at a glance if voltage is within a nominal range.
                                                                                                               www.furmanpower.com     13
                                     220V-440V PRO LINE PRODUCT CATALOG
                                              FEATURES
     The BB-RS232 Adaptor provides
                                              •   Control for individual outlet banks featuring power, trigger and delay settings
     Ethernet connectivity to BlueBOLT-
                                              •   Auto rebooting for connected network devices
     supported products that are otherwise
                                              •   Remote diagnostics: check unit status and incoming line voltages
     only capable of RS-232 communication.
                                              •   Easy, plug-in installation
     Once the Adaptor is connected between    •   Email alerts for over and under-voltages help you anticipate or prevent service calls
     the BlueBOLT supported product
     (via RS-232) and the site’s Local Area
     Network (via Ethernet), the product
     can communicate with our BlueBOLT
     servers or a local control system.
                                                                                    Run Times
                                                                                                      Extended Run Time with F1500*
                                                                                                      Half Load...........................................100 Min.
                                                                                                      Full Load .............................................45 Min.
14
                                           BlueBOLT NETWORK MANAGEMENT
                                                            TECHNOLOGY
                                      What Is BlueBOLT?
                                      BlueBOLT is a free, cloud-based platform
                                      for control and monitoring of Panamax
                                      and Furman power management prod-
                                      ucts. BlueBOLT can be used in integrated
                                      electronics systems to drastically reduce
                                      service calls by remotely rebooting problem
                                      components, send alerts regarding onsite
                                      system issues, manage energy use, monitor
                                      network connectivity, and much more.
                                      Applications:
                                      Retail
                                      Restaurants/Bars
                                      House of Worship
                                      Medical Offices
                                      Fitness Centers
                                      Education
                                      Dance Clubs
                                      Property Management
                                      Research/Labs
                                      Corporate Meeting Rooms
                                      Auditoriums
                                      Hotels/Hospitality
                                                                  www.furmanpower.com   15
                                    220V-440V PRO LINE PRODUCT CATALOG
     GLOBAL COMPATIBILITY
     Furman products are engineered to be universally
                                                                                            SLOVAKIA
     ADP-IEC UK (0.1 meter long)                        UK-10 (2.5 meters long)                        UK-16 (2.5 meters long)
     To plug components with UK plugs into              For use with 10A Furman products               For use with 10A Furman products
     Furman products with 10A IEC outlets.              with removable IEC power cord.                 with removable IEC power cord.
     10A Male IEC to Female UK.                         10A IEC Female to 10A UK Male.                 16A IEC Female to 16A UK Male.
     ADP-IEC EURO (0.1 meter long)                     SCHUKO-10 (2.5 meters long)                     SCHUKO-16 (2.5 meters long)
     To plug components with European                  For use with 10A Furman products                For use with 10A Furman products
     SCHUKO plugs into Furman products                 with removable IEC power cord.                  with removable IEC power cord.
     with 10A IEC outlets. 10A Male IEC                10A IEC Female to SCHUKO Male.                  16A IEC Female to SCHUKO Male.
     to Female SCHUKO.
16
                                                                                                                    GLOBAL COMPATIBILITY
                                                                                                                               www.furmanpower.com            17
                   © 2017 Core Brands, LLC. All rights reserved.
         Furman® is a registered trademark of Core Brands, LLC.
                                   Part# L1P201 Rev D, 8/2017
                                       Petaluma, CA 94954, USA
18