Diaphragm Valves
• Excellent durability and reliability
• Ideal for CMP Slurry, DI water and chemical
process
• Easily incorporated into OEM equipment
• Specific solutions for your application
SDV Single Diaphragm
Single Diaphragm Valve Single diaphragm valves are an economical
On/Off Manual/Pneumatic solution for a commodity diaphragm valve. SDV
Flare, S-300, FNPT, Tube offers a large size range with multiple connection
58psi options. Available with air-actuated, manual multi-
1/4” - 1/2” turn and toggle actuators.
MPV Multiport Valve Manifolds
Multiport Diaphragm Valve The most versatile of all diaphragm valves,
On/Off Manual/Pneumatic offering custom manifolds in a variety of end
Flare, S-300, FNPT, Tube connections, actuators and options.
72.5psi
1/4” - 1” Tested at pressure beyond 1,000,000 cycles.
Poppet-style diaphragm allows media to
recirculate on multiple feed lines while valve
remains closed to the point-of-use.
DIV Diverting Valve
Diverting Valve The true diverting valve was developed for three-
On/Off Manual/Pneumatic way distribution with a high purity poppet-style
Flare, S-300, FNPT, Tube diaphragm valve. The small footprint makes the
72.5psi DIV ideal for OEM use.
1/4” - 1/2”
655 Andover St. Lawrence, MA 01843 • Tel: 800-343-3618
www.asahi-america.com • asahi@asahi-america.com
Rev. 0720
Pinch Valves
• No cohesion or decline in sealing
performance
• Ideal for CMP slurry and DI water
• Easily incorporated into OEM equipment
• Completely flushable in full open position
PV3
Pneumatic Pinch Valve
On/Off
1/4” - 1” Flare, S-300, FNPT
43.5psi End Connector (PTFE)
Compressor Shaft (PVDF)
Tube (PTFE Blend)
Straight Flow
PVM
The straight flow path applies no stress to the
medium. There is almost no influence to the
Manual Pinch Valve particle size, even with highly coherent fluids such
Adjustable Flow as slurry, it can also be used for DI water. There is
1/4” - 1” Flare, S-300, FNPT no restriction on the flow path, which gives a high
72.5psi CV value and the ability to fully flush.
Excellent Durability
The use of a pinch seal structure provides
superior durability against foreign substances
caught in the flow passage. The tube does not
PVSL break down or shed, which proves reliable over 2
Slow Leak Pinch Valve million cycles.
Pneumatic w/ Manual Stop
Seal Design
1/4” - 1” Flare, S-300, FNPT
43.5psi
A proprietary PTFE blend tube design provides a
full seal without crimping when the valve closes.
The tubing completely restores to the original open
shape. Slurry evaluation test shows there is no
decline in the sealing performance.
655 Andover St. Lawrence, MA 01843 • Tel: 800-343-3618
www.asahi-america.com • asahi@asahi-america.com
Rev. 0720
Needle Valve
• True linear flow
• Panel mount for easy installation
• PTFE diaphragm isolates media from stems
• Straight, horizontal and vertical L available
NVM Linear Flow
Manual Needle Valve
Fine Regulation The special diaphragm needle shape, in
Flare, Baseplate conjunction with dual stems create true linear
72.5psi flow. Easy to adjust to the desired flow rate
1/4” - 1/2” without spiking like standard needle valves.
Configurations
The panel mount design
makes it easy to incorporate
1600
into equipment. Different angle
patterns mean less fittings,
1400 Competitor B which increases profitability
and reduces potential weak
points.
1200 Asahi NVM
1000
Flow (mL / min)
800 Competitor A Diaphragm Design
600 Unique diaphragm design keeps media from
contacting the dual stems, resulting in an
ultrapure valve. A sealing cone is placed around
400 the needle to
protect the PTFE
200
needle tip and
completely stop
flow when closed.
0 All PTFE wetted
parts provide
excellent chemical
0 1 2 3 4 5 6 7 compatibility.
Number of handle rotations
655 Andover St. Lawrence, MA 01843 • Tel: 800-343-3618
www.asahi-america.com • asahi@asahi-america.com
Rev. 0720
Regulators & Flow Control
• Precise and accurate control over pressure
via pneumatic control
• Fluctuations in pressure are instantly adjusted
• Flow control for blend processing
• Point-of-use regulation
Pressure Regulator
HPR-L
Pressure Regulator HPR-L series pressure regulators instantly control
Full shut off (fail-close) fluctuations in pressure due to the quick response
Flare, S-300, FNPT, Tube of the valve. The pressure does not spike, even
72.5psi just after the pump turning on. Sophisticated
1/8” - 1” diaphragm design precisely maintains pressure.
Balance out diaphragm pumps prior to reaching
the point of use.
HPRL-M Manual Pressure Regulator
Pressure Regulator HPRL-M series pressure regulators offer the same
Full shut off (fail-close) technology found in the pneumatic version, with
Flare, S-300, FNPT, Tube manual adjustment. They are easy-to-operate and
72.5psi simple to install. Adjust pressure by rotating the
1/4” - 1/2” handle. Once the desired pressure is set, it
automatically controls fluctuations.
Slurry Pressure Regulator
HPR-S
Slurry Pressure Regulator The internal structure prevents clogging and
Flare, S-300, FNPT, Tube cohesion in CMP slurry applications. It is
72.5psi pneumatically-controlled to provide adjustments in
1/4” - 1/2” pressure. In case of failure, the valves shuts off
50 cc/min - 5 LPM flow.
CFV Constant Flow Valve
Constant Flow Valve The CFV incorporates an orifice into the PTFE
Full shut off diaphragm. The simple system design eliminates
Flare, S-300, FNPT, Tube concerns about pressure fluctuations due to pipe
72.5psi 1/4” length and back pressure.
10 cc/min - 2 LPM
655 Andover St. Lawrence, MA 01843 • Tel: 800-343-3618
www.asahi-america.com • asahi@asahi-america.com
Rev. 0720
PVC Valves
• Specialty PVC valves based on Dymatrix™
technology provides proven results
• Large size range and small footprints
• True union connections for easy installation
HDV12/AD16 Diaphragm Valve
Diaphragm Valve HDV12 and AD16 diaphragm valves are the first
Socket, Threaded, Flanged PVC valves designed from the ground up to be an
72.5psi 1/2” - 1” actuated valve. This compact valve is ideal for
58psi 1-1/4” - 2” PVC skid fabrications and water stands. Many
options are available in addition to the standard
valve.
HDV-W Water Hammer Valve
Water Hammer - Less Based on the successful HDV12, the HDV-W is
Socket, Threaded, Flanged designed to combat the effects of potential water
72.5psi 1/2” - 1” hammers. This valve’s diaphragm is designed to
58psi 1-1/4” - 2-1/2” remain sealed even when pressure and flow
fluctuates downstream. A simple way to protect
your upstream equipment.
QDV Quick Drain Valve
Quick Drain Valve Plunger-style valve installs inline without taking up
PVC & PP additional space for its integral double acting
Socket, Threaded, Flanged actuator. True union design can be installed with
2.9psi ease. Available in PP and PVC.
1-1/2” - 4”
BVX Ball Valve Connector
Ball Valve Flare Easily incorporate tubing into your existing system.
Flare, S-300, Hose Barb The ball valve is socket welded into PVC, PP and
1/2” x 1/4”, 3/8”, 1/2” PVDF pipe and the tubing connection is added to
3/4” x 3/4” & 1” x 1” the other side. Experience the security of proven
72.5psi leak proof ball valve connections, now for your
tubing adapters.
655 Andover St. Lawrence, MA 01843 • Tel: 800-343-3618
www.asahi-america.com • asahi@asahi-america.com
Rev. 0720